Materials Panel Gary Flemming Window Business Manager YKK AP America Inc.
maintaining aesthetic flair while dealing with real-time issues presented by new and aging buildings
key themes ... New Construction
Renovation
Daylighting
Functionality
(maximize DLO’s, Solar Control)
(meet new tenant’s needs)
Sightlines
Aesthetics
(minimize & controlled across materials)
(modernize, historical preservation)
Ventilation
Operation
(indoor air quality)
(restore functionality)
Thermal Performance (reduce energy loss, lower HVAC demand)
Security / Safety (access control, blast & hurricane mitigation)
COST!
(seeking value-rich solutions)
first question ... what do you want to achieve?
Renovation ... Before
Grand Yacht Club - Ft. Lauderdale, FL After
Renovation ...
Punta Gorda High School
Before
Impact Resistant ADA Compliant Historical Preservation
After
New Construction ...
Aesthetics with Geometric Shapes
New Construction ... Minimized & Consistent Sightlines Structurally Glazed Vents designed for use with Curtain Walls, Window Walls, or Storefronts
8 operable units (can you find them?)
New Construction ... Minimized & Consistent Sightlines Structurally Glazed Vents designed for use with Curtain Walls, Window Walls, or Storefronts
maintaining aesthetic flair while dealing with real-time issues
SSG Vents (Zero Sightline Vents)
... a cost-effective solution
Cost-effective Solution ...
Fixed over Casement Windows with Mulls Cost per SF $50
Store Front with SSG Vents Cost per SF $35
SSG Vents ...
aka “Zero Sightline” Vents
SSG Vents ...
non-thermal vent
aka “Zero Sightline� Vents
thermally broken vent
SSG Vents ...
aka “Zero Sightline” Vents
NFRC Thermal Modeling 49° F 39° F
non-thermal vent
thermally broken vent
U-factor: 0.46
U-factor: 0.41
CW Rating (AAMA Class)
AW Rating (AAMA Class) Increased Surface Temperature
maintaining aesthetic flair while dealing with real-time issues
... a few CASE STUDIES
Case Study ...
Villanova University, Dougherty Hall
Original Building Circa 1955, Dining Hall addition 1964
Case Study ...
Villanova University, Dougherty Hall
Case Study ... Before
Mill Finish U-factor: 1.19 SHGC: 0.78
Villanova University, Dougherty Hall Vents
After
Champaign Bronze, Anodized Plus速 U-factor: 0.42 SHCG: 0.22
Case Study ...
Villanova University, Dougherty Hall
§ Low-E coating hides hardware § Traditional cams § Multipoint locks § Egress
§ Casement & project out vents § PO 70” x 66”
§ Uniform sight lines § Flexible Vent locations
Champaign Bronze, Anodized Plus U-factor: 0.42 SHCG: 0.22
Case Study ...
Davis Restoration, Historical Warehouse
Steel Windows Clear Glass High Air Infiltration
Case Study ... Before
After
Davis Restoration, Historical Warehouse
Case Study ...
Davis Restoration, Historical Warehouse
Before
After
U-factor: 1.19
U-factor: 0 .46
SHGC: 0.82
SHGC: 0.24
Case Study ...
Davis Restoration, Historical Warehouse
Window Solution
Storefront Zero Sightline Solution
§ Storefront w/SSG Vent replacement for steel windows § Small uniform sightlines § Grid looks similar to original § Cost per SF $37/SF (23% lower than window solution) § System can Span 10’+ (window systems typically span 7’) § Tested vent size 70” x 60” § Improved Thermal Performance
maintaining aesthetic flair while dealing with real-time issues
Hung Windows w/ Panning ... a cost-effective solution
Case Study ...
Lee High School, Campus Renovation
A mix of new construction, renovation, and code compliance
Case Study ...
Lee High School, Campus Renovation
1st renovation completed in the 1980’s
Original & New Openings
Wood deterioration was evident. Replaced with concrete and double wood buck.
Case Study ...
Lee High School, Campus Renovation
Full length Sill starter w/ end dam and tied to jamb for enhanced waterproofing
Case Study ...
Lee High School, Campus Renovation
Primary Sealant Support Mulls Sill Starter
Post-set Colonial Panning
Case Study ...
Lee High School, Campus Renovation
Post renovation: maintains historic look, complies with new codes
maintaining aesthetic flair while dealing with real-time issues
Advanced Thermal Performance ... product evolution continues
Product Evolution... 3 ½” Window System Thermal Barrier
Wide Thermal Barrier
Air Tight Gasket
Traditional Method YOW 350 T
Advanced Method YOW 350 XT
Product Evolution... 3 ½” Window System NFRC Thermal Modeling
37° F
Traditional Method YOW 350 T
62° F
Advanced Method YOW 350 XT
maintaining aesthetic flair while dealing with real-time issues
... supported by YKK AP America
Gary Flemming Window Business Manager YKK AP America Inc. 941-928-4754 garyflemming@ykkap.com