1: DB Studio - Code Analysis

Page 1

Building Code Analysis Worksheet RE: https://codes.iccsafe.org/content/IBC2018?site_type=public and Building Efficiency.pdf

Devyn Brown IND 335

Programming Document Outline I. Project Description: Tenant Office Space Building Type IIA - Sprinklered Floor Square Footage = 19,409 Total Sq. Ft = Usable Sq. Ft. = 6th Floor Total Sq. Ft. 19,409

Assignable Assignable

75% Efficiency 14,556 SF Assignable

Tenant Square Footage = 2844 S.F. Total Sq. Ft = Assignable Usable Sq. Ft. = Assignable Tenant Total Sq. Ft. 2734

75% Efficiency 2,050 SF Assignable

+ +

Circulation Circulation

+

12.5% Circulation 2,426 SF Circulation 16,982 SF Usable + +

Misc. 12.5% Misc. 2,426 SF Misc

Circulation Circulation

+

12.5% Circulation 341 SF Circulation 2,391 SF Usable

Misc. 12.5% Misc. 341 Misc

75% Efficiency, 12.5% Circulation Factor, 12.5% Misc. (mechanical, structure, walls, public toilets, janitor closets, unassigned storage)

II.

Programming (Tenant) A. Programming Analysis Usable = Area Sq. Ft.

Qty

100 200 300 100 300 200 350 250 20 20

1 1 1 1 1 1 1 1 1 1

Description

Reception Waiting Conference Room Coffee Bar/Kitchenette Principal Office Admin Office Collaborative Studio for 4 Resource Library/Plotter & File Room Storage Closet Power/Data Closet

Sub Total: Program Misc . Un-assignable

Mechanical, Structure/Walls, Public Toilets, Janitor Closets, Unassigned Stg.

Assignable

+

Circulation

Usable S.F. (gross)

Assignable S.F. (.75% net) 0.75

Circulation (12.5% c.f.) 0.125

114 228 342 114 342 228 600 285 23 23

100 200 300 100 300 200 525 250 20 20

14 28 42 14 42 28 75 35 3 3

2299 342


Circulation for Misc. Unassigned Areas Total Space Requirement

III.

1,833 SF

Preliminary Codes Analysis A. Occupancy Classification (Occupancy Classifications Handout) B. Egress (Note Exceptions) Maximum Floor Area Allowances: IBC Table 1004.5 Minimum # of Exits or Access to Exits per Story: IBC Table 1006.3.2 Stories with One Exit or Access to One Exit for Other Occupancies: IBC Table 1006.3.3(2) Exit Access Travel Distance: IBC Table 1017.2 Means of Egress Sizing: IBC Section 1005 (Stairways: 0.3” per Occupant | Other/Horizontal: 0.2”/Occupant) Half Diagonal Rule

Area

Useable S.F. Net or Gross

Occupancy Load Factor

Occupant Load

Reception

114 G

150 G

1

Means of Egress per area 1

Waiting

200 N

7N

29

1

Conference Room

300 N

15 N

20

1

Coffee Bar/Kitchenette

114

150 G

1

1

Principal Office

342

150 G

3

1

228

150 G

2

1

Collaborative Studio for 4

600

150 G

4

1

Resource Library/Plotter & File

285

100 G

3

1

Storage Closet

23

150 G

1

1

Power/Data Closet

23

150 G

1

1

Admin Office

Tenant Total Occupancy Tenant Means of Egress

Occupancy Classification

GROUP B

65 2 means of egress

Egress Data Min. width Max. distance 44” (36” door) Door swing in 44” (36” door) Door swing in 44” (36” door) Door swing in 44” (36” door) Door swing in 44” (36” door) Door swing in 44” (36” door) Door swing in 44” (36” door) Door swing in 44” (36” door) Door swing in 44” (36” door) Door swing in 44” (36” door) Door swing in

300’


Notes: C. Plumbing Minimum Number of Required Plumbing Fixtures: IBC Table 2902.1 Area

Occ. Class. B

6th floor

Occ. Load 120

Water Closets Male Female 2 2

Lavatories Male Female 1 1

Fountains 2

Other Fixtures 1 service sink

Note: Assume 50% male and 50% female unless specific demographics for gender are available or as indicated by codes officials Total Facility Plumbing: Male

Toilets/Urinals: Lavatories:

2 1

Total Facility Plumbing: Female

Toilets Lavatories:

2 1

Total Facility Fountains Total Facility Other fixtures

2 1

D. Fire Separation Required Separation of Occupancies (hours): IBC Table: 508.4 Upon determination of Spatial Adjacencies/Relationships, determine fire rating (in hours) between areas as required. Note: Areas not included below require no fire separation Area 1

Area 2 Corridor Neighboring Tenant

Tenant Tenant

Separation in hours 1 hour 1 hour

E. Interior Finishes Interior Wall and Ceiling Finish Requirements by Occupancy: IBC Table: 803.13 Upon determination of Spatial Adjacencies/Relationships, determine fire rating (in hours) between areas as required. Note: Areas not included below require no fire separation Space Tenant

Occupancy Classification B

Interior Exit Stairways/Ramps B

Corridors & Enclosures C

Rooms and Enclosed Spaces C



Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.