DILUX REPORT (ILLUMINATION)

Page 1

Date

13-02-2021

illumination model

SUBMITTED BY-

Created with DIALux

BISHAL ROY 001710201042 B. ARCH, JADAVPUR UNIVERSITY


illumination model

Preliminary remarks Hereby I acknowledge Mr Satvaya Parthasarathi for his systematic guidance and immense assistance in this journey of Lighting Design of a 3BHK residential house made me capable and confident to arrive at conclusive design solution and oblige. Notes on planning: The energy consumption quantities do not take into account light scenes and their dimming levels. The daylight was also taken into account for the calculations in the course of this planning. The following parameters formed the basis for the calculations: Location: Kolkata Zenith luminance: 6316 cd/m2 Pollution category: Medium to heavy traffic, dust exposure under 600 microgram/cubic metre

Notes on planning: The energy consumption quantities do not take into account light scenes and their dimming levels.


illumination model

Content

Cover page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1. . . . . . . . . . . . . . . . . . . . . . . . . Preliminary remarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2. . . . . . . . . . . . . . . . . . . . . . . . . . . Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3. . . . . . . . . . . . . . . . . . . . . . Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7. . . . . . . . . . . . . . . . . . . . . . . . . Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8. . . . . . . . . . . . . . . . . . . . . . Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9. . . . . . . . . . . . . . . . . . . . . . . . . . .

Product data sheets

............................ Disano Illuminazione - Fosnova Eco Lex 3 3000K CLD CELL-DI white (1x . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 led_el3_3000K) ............................. ETAP - (1x LED HP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 ............................. Targetti Sankey S.p.A. - MAGMA WALL MWFL (1x HIT-CE 70W 4200K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Site 1 ............................ Calculation objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 ............................ Calculation surface 1 / Perpendicular illuminance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Site 1

Building 1 ............................ Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Site 1 - Building 1

Storey 1 ......................... Room List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Luminaire list 23 ............................ Calculation objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

Site 1 - Building 1 - Storey 1

bedroom 2

......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Luminaire layout plan 29 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Luminaire list 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calculation objects 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Workplane (bedroom 2) / Perpendicular illuminance (adaptive) 35


illumination model

Content Site 1 - Building 1 - Storey 1

toilet 1

......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Luminaire layout plan 38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Luminaire list 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calculation objects 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Workplane (toilet 1) / Perpendicular illuminance (adaptive) 43

Site 1 - Building 1 - Storey 1

toilet 2

......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Luminaire layout plan 46 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Luminaire list 48 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calculation objects 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Workplane (toilet 2) / Perpendicular illuminance (adaptive) 51

Site 1 - Building 1 - Storey 1

Room 4

......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Luminaire layout plan 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Luminaire list 56 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calculation objects 57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Workplane (Room 4) / Perpendicular illuminance (adaptive) 59

Site 1 - Building 1 - Storey 1

closet 4

......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Luminaire layout plan 62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Luminaire list 64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calculation objects 65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Workplane (closet 4) / Perpendicular illuminance (adaptive) 67

Site 1 - Building 1 - Storey 1

closet 5

......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Luminaire layout plan 70 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Luminaire list 72 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calculation objects 73. . . . . . . . . . . . . . . . . . . . . . . . . . .


illumination model

Content Workplane (closet 5) / Perpendicular illuminance (adaptive)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 ............................

Site 1 - Building 1 - Storey 1

living and dining

......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 ............................. Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78 ............................ Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calculation objects 82. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Workplane (living and dining) / Perpendicular illuminance (adaptive) 84

Site 1 - Building 1 - Storey 1

closet 6

......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 ............................. Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87 ............................ Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calculation objects 90. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Workplane (closet 6) / Perpendicular illuminance (adaptive) 92

Site 1 - Building 1 - Storey 1

closet 1

......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 ............................. Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95 ............................ Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calculation objects 98. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Workplane (closet 1) / Perpendicular illuminance (adaptive) 100

Site 1 - Building 1 - Storey 1

bedroom 3

.......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 .............................. Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103 .............................. Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 ............................. Calculation objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Workplane (bedroom 3) / Perpendicular illuminance (adaptive) 109

Site 1 - Building 1 - Storey 1

closet 3 .......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110


illumination model

Content

.............................. Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Luminaire list 114 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Calculation objects 115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Workplane (closet 3) / Perpendicular illuminance (adaptive) 117. . . . . . . . . . . . . . . . . . . . . . . . . . .

Site 1 - Building 1 - Storey 1

bedroom 1

.......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............................. Luminaire layout plan 120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Luminaire list 123 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Calculation objects 124 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Workplane (bedroom 1) / Perpendicular illuminance (adaptive) 126

Site 1 - Building 1 - Storey 1

closet 2

.......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............................. Luminaire layout plan 129 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Luminaire list 131 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................ Calculation objects 132 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Workplane (closet 2) / Perpendicular illuminance (adaptive) 134. . . . . . . . . . . . . . . . . . . . . . . . . . .

Site 1 - Building 1 - Storey 1

Room 14 .......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Calculation objects 137 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Workplane (Room 14) / Perpendicular illuminance (adaptive) 139

Site 1 - Building 1 - Storey 1

porch

.......................... Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 .............................. Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142 .............................. Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 ............................. Calculation objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ............................. Workplane (porch) / Perpendicular illuminance (adaptive) 147

......................... Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148


illumination model

Description

SERVICES AND EQUIPMENT -3

7


illumination model

Images

SERVICES AND EQUIPMENT -3

8


illumination model

Luminaire list Φtotal

Ptotal

Luminous efficacy

144642 lm

1850.8 W

78.2 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

21

Disano

Eco Lex 3

23.0 W

2070 lm

90.0 lm/W

14

ETAP

R728/ LEDN3645

42.7 W

4552 lm

106.6 lm/W

11

TARGETTI

1T2289N +1T2559N

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

Fosnova Eco Lex 3 3000K CLD CELL-DI white

MAGMA WALL MWFL

9


illumination model

Product data sheet Disano Fosnova Eco Lex 3 3000K CLD CELL-DI white

Article No.

Eco Lex 3

P

23.0 W

ΦLamp

2070 lm

ΦLuminaire

2070 lm

η

100.00 %

Luminous efficacy

90.0 lm/W

CCT

3000 K

CRI

83

Eco Lex LED is a new series of recessed spotlights that combines advanced technology and energy savings with an-easy-to-install, low cost, robust and durable fixture. Available in three sizes with a diam. of 100, 164, 192, 220 mm, they cover a wide range of cutout holes. Housing: in die cast aluminium Diffuser: The shield consists of a laser-cut slab that serves as a lens for its effect of concentric circles. These decorations create a pattern, with variable distances; the closer they get to the centre, the closer they come together achieving excellent visual comfort without glare Painting: dust painted, using polyester epoxy paint to withstand UV rays. Standard supply: Includes adjustable steel bracket. Regulations: Manufactured in accordance with standards EN60598 – CEI 34 –21. Degree of protection in accordance with standards EN60529. DIM IGBT Power factor: ≥ 0.9 Photobiological safety class: Exempt group. Luminous flux maintenance 70%: 40.000h (L70B50). recessed Ø 198/216mm

SERVICES AND EQUIPMENT -3

Polar LDC

UGR diagram (SHR: 0.25)

10


illumination model

Product data sheet ETAP

Article No.

R728/LEDN3645SX1

P

42.7 W

ΦLamp

4550 lm

ΦLuminaire

4552 lm

η

100.04 %

Luminous efficacy

106.6 lm/W

CCT

4000 K

CRI

100

Polar LDC

square - surface mounted luminaire lens lamp type: HIGH POWERLED

UGR diagram (SHR: 0.25)

SERVICES AND EQUIPMENT -3

11


illumination model

Product data sheet TARGETTI MAGMA WALL MWFL

Article No.

1T2289N+1T2559N

P

70.0 W

ΦLamp

6600 lm

ΦLuminaire

3404 lm

η

51.58 %

Luminous efficacy

48.6 lm/W

CCT

4200 K

CRI

90

Polar LDC

Professional projector for metal halide lamps. Die cast painted aluminium power supply and optics housings. Wall mounting system through die cast aluminium bracket which allows +/-120° adjustment on the horizontal axis of fixture body. 180° adjustable optics on the vertical axis with mechanical locking device to ensure aiming stability.To be completed with the new EMR precision elliptical optics with convex facets. Optics are equipped with ring and protection glass to be ordered separately in the same colour of the fixture. Bayonet lock mounting system for an easy relamping. Anti-glare steel spill ring inside the optics housing. Electronic power supply separated from the optics housing in order to optimize the heat dissipation.

SERVICES AND EQUIPMENT -3

12


illumination model

Site 1

Calculation objects

13


illumination model

Site 1

Calculation objects Calculation surfaces Properties

Ē

Emin

Emax

g1

g2

Index

Calculation surface 1 Perpendicular illuminance Height: 0.000 m

124 lx

0.00 lx

1071 lx

0.00

0.00

S31

Utilisation profile: DIALux presetting, Standard (outdoor transportation area)

SERVICES AND EQUIPMENT -3

14


illumination model

Site 1

Calculation surface 1

Properties

Ē

Emin

Emax

g1

g2

Index

Calculation surface 1 Perpendicular illuminance Height: 0.000 m

124 lx

0.00 lx

1071 lx

0.00

0.00

S31

Utilisation profile: DIALux presetting, Standard (outdoor transportation area)

SERVICES AND EQUIPMENT -3

15


illumination model

Building 1

Luminaire list Φtotal

Ptotal

Luminous efficacy

144642 lm

1850.8 W

78.2 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

21

Disano

Eco Lex 3

23.0 W

2070 lm

90.0 lm/W

14

ETAP

R728/ LEDN3645

42.7 W

4552 lm

106.6 lm/W

11

TARGETTI

1T2289N +1T2559N

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

Fosnova Eco Lex 3 3000K CLD CELL-DI white

MAGMA WALL MWFL

16


illumination model

Building 1 · Storey 1

Room List

17


illumination model

Building 1 · Storey 1

Room List bedroom 1 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

170.8 W

18.53 m²

9.22 W/m² = 1.21 W/m²/100 lx (Room)

760 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

4

ETAP

42.7 W

4552 lm

R728/ LEDN3645

bedroom 2 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

170.8 W

21.18 m²

8.06 W/m² = 1.26 W/m²/100 lx (Room)

640 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

4

ETAP

42.7 W

4552 lm

R728/ LEDN3645

bedroom 3 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

170.8 W

18.82 m²

9.07 W/m² = 1.22 W/m²/100 lx (Room)

744 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

4

ETAP

42.7 W

4552 lm

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

18


illumination model

Building 1 · Storey 1

Room List closet 1 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

42.7 W

4.29 m²

9.96 W/m² = 1.42 W/m²/100 lx (Room)

699 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

1

ETAP

42.7 W

4552 lm

R728/ LEDN3645

closet 2 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

70.0 W

2.74 m²

25.51 W/m² = 2.30 W/m²/100 lx (Room)

1111 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

1

TARGETTI

70.0 W

3404 lm

1T2289N +1T2559N

MAGMA WALL MWFL

closet 3 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

70.0 W

2.59 m²

27.03 W/m² = 2.25 W/m²/100 lx (Room)

1201 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

1

TARGETTI

70.0 W

3404 lm

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

19


illumination model

Building 1 · Storey 1

Room List closet 4 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

70.0 W

1.44 m²

48.53 W/m² = 2.41 W/m²/100 lx (Room)

2017 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

1

TARGETTI

70.0 W

3404 lm

1T2289N +1T2559N

MAGMA WALL MWFL

closet 5 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

42.7 W

1.29 m²

33.06 W/m² = 2.66 W/m²/100 lx (Room)

1242 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

1

ETAP

42.7 W

4552 lm

R728/ LEDN3645

closet 6 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

70.0 W

1.84 m²

38.04 W/m² = 2.36 W/m²/100 lx (Room)

1611 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

1

TARGETTI

70.0 W

3404 lm

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

20


illumination model

Building 1 · Storey 1

Room List living and dining Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

483.0 W

92.94 m²

5.20 W/m² = 1.25 W/m²/100 lx (Room)

416 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

21

Disano

23.0 W

2070 lm

Eco Lex 3

Fosnova Eco Lex 3 3000K CLD CELL-DI white

porch Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

140.0 W

12.06 m²

11.61 W/m² = 2.26 W/m²/100 lx (Room)

515 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

2

TARGETTI

70.0 W

3404 lm

1T2289N +1T2559N

MAGMA WALL MWFL

Room 4 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

70.0 W

1.24 m²

56.55 W/m² = 2.51 W/m²/100 lx (Room)

2257 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

1

TARGETTI

70.0 W

3404 lm

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

21


illumination model

Building 1 · Storey 1

Room List toilet 1 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

140.0 W

8.95 m²

15.65 W/m² = 2.08 W/m²/100 lx (Room)

753 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

2

TARGETTI

70.0 W

3404 lm

1T2289N +1T2559N

MAGMA WALL MWFL

toilet 2 Ptotal

ARoom

Lighting power density

Ēhorizontal (Workplane)

140.0 W

9.00 m²

15.56 W/m² = 2.09 W/m²/100 lx (Room)

745 lx

pcs.

Manufacturer Article No. Article name

P

ΦLuminaire

2

TARGETTI

70.0 W

3404 lm

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

22


illumination model

Building 1 · Storey 1

Luminaire list Φtotal

Ptotal

Luminous efficacy

144642 lm

1850.8 W

78.2 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

21

Disano

Eco Lex 3

23.0 W

2070 lm

90.0 lm/W

14

ETAP

R728/ LEDN3645

42.7 W

4552 lm

106.6 lm/W

11

TARGETTI

1T2289N +1T2559N

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

Fosnova Eco Lex 3 3000K CLD CELL-DI white

MAGMA WALL MWFL

23


illumination model

Building 1 · Storey 1

Calculation objects

24


illumination model

Building 1 · Storey 1

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

(Target) Workplane (bedroom 2) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

640 lx (≥ 500 lx)

308 lx

924 lx

0.48

0.33

S2

Workplane (toilet 1) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

753 lx (≥ 500 lx)

127 lx

4123 lx

0.17

0.031

S4

Workplane (toilet 2) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

745 lx (≥ 500 lx)

128 lx

4098 lx

0.17

0.031

S6

Workplane (Room 4) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

2257 lx (≥ 500 lx)

449 lx

4111 lx

0.20

0.11

S8

Workplane (closet 4) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

2017 lx (≥ 500 lx)

345 lx

4076 lx

0.17

0.085

S10

Workplane (closet 5) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1242 lx (≥ 500 lx)

1105 lx

1312 lx

0.89

0.84

S12

Workplane (living and dining) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

416 lx (≥ 500 lx)

16.9 lx

723 lx

0.041

0.023

S14

Workplane (closet 6) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1611 lx (≥ 500 lx)

244 lx

4032 lx

0.15

0.061

S16

Workplane (closet 1) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

699 lx (≥ 500 lx)

368 lx

929 lx

0.53

0.40

S18

Workplane (bedroom 3) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

744 lx (≥ 500 lx)

406 lx

977 lx

0.55

0.42

S20

Workplane (closet 3) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1201 lx (≥ 500 lx)

157 lx

3954 lx

0.13

0.040

S22

SERVICES AND EQUIPMENT -3

25


illumination model

Building 1 · Storey 1

Calculation objects Properties

Ē

Emin

Emax

g1

g2

Index

(Target) Workplane (bedroom 1) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

760 lx (≥ 500 lx)

429 lx

990 lx

0.56

0.43

S24

Workplane (closet 2) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1111 lx (≥ 500 lx)

151 lx

3938 lx

0.14

0.038

S26

Workplane (Room 14) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

0.00 lx (≥ 500 lx)

0.00 lx

0.00 lx

-

-

S28

Workplane (porch) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

515 lx (≥ 500 lx)

47.0 lx

3905 lx

0.091

0.012

S30

SERVICES AND EQUIPMENT -3

26


illumination model

Building 1 · Storey 1 · bedroom 2

Summary

Ground area: 21.18 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 2.400 m

27


illumination model

Building 1 · Storey 1 · bedroom 2

Summary Results Symbol

Calculated

Target

Ē

640 lx

≥ 500 lx

g1

0.48

-

Consumption values

Consumption

[340 - 470] kWh/a

max. 750 kWh/a

Lighting power density

Room

8.06 W/m²

-

-

1.26 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

4

ETAP

42.7 W

4552 lm

106.6 lm/W

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

28


illumination model

Building 1 · Storey 1 · bedroom 2

Luminaire layout plan

29


illumination model

Building 1 · Storey 1 · bedroom 2

Luminaire layout plan

Manufacturer

ETAP

Article No.

R728/LEDN3645SX1

Article name

2 x ETAP R728/LEDN3645SX1 Type

Field Arrangement

X

Y

Mounting height

Luminaire

1st luminaire (X/Y/Z) 0.821 m, 3.781 m, 2.400 m

0.821 m

3.781 m

2.400 m

1

X-direction

3 pcs., Center - center, Distances not equal

3.889 m

3.781 m

2.400 m

2

Y-direction

1 pcs., Center - center, Distances not equal

Arrangement

A1

X

Y

Mounting height

1st luminaire (X/Y/Z) 3.836 m, 0.651 m, 2.400 m

3.836 m

0.651 m

2.400 m

3

X-direction

0.767 m

0.651 m

2.400 m

4

2 x ETAP R728/LEDN3645SX1 Type

Field Arrangement

3 pcs., Center - center, Distances not equal

SERVICES AND EQUIPMENT -3

Luminaire

30


illumination model

Building 1 · Storey 1 · bedroom 2

Luminaire layout plan Y-direction

1 pcs., Center - center, Distances not equal

Arrangement

A2

SERVICES AND EQUIPMENT -3

31


illumination model

Building 1 · Storey 1 · bedroom 2

Luminaire list Φtotal

Ptotal

Luminous efficacy

18208 lm

170.8 W

106.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

4

ETAP

42.7 W

4552 lm

106.6 lm/W

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

32


illumination model

Building 1 · Storey 1 · bedroom 2

Calculation objects

33


illumination model

Building 1 · Storey 1 · bedroom 2

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

308 lx

924 lx

0.48

0.33

Index

(Target) Workplane (bedroom 2) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

640 lx (≥ 500 lx)

S2

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

34


illumination model

Building 1 · Storey 1 · bedroom 2

Workplane (bedroom 2)

Properties

Ē

Emin

Emax

g1

g2

308 lx

924 lx

0.48

0.33

Index

(Target) Workplane (bedroom 2) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

640 lx (≥ 500 lx)

S2

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

35


illumination model

Building 1 · Storey 1 · toilet 1

Summary

Ground area: 8.95 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 1.900 m

36


illumination model

Building 1 · Storey 1 · toilet 1

Summary Results Symbol

Calculated

Target

Ē

753 lx

≥ 500 lx

g1

0.17

-

Consumption values

Consumption

390 kWh/a

max. 350 kWh/a

Lighting power density

Room

15.65 W/m²

-

-

2.08 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

2

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

37


illumination model

Building 1 · Storey 1 · toilet 1

Luminaire layout plan

38


illumination model

Building 1 · Storey 1 · toilet 1

Luminaire layout plan

Manufacturer

TARGETTI

Article No.

1T2289N+1T2559N

Article name

MAGMA WALL MWFL

2 x Targetti Sankey S.p.A. MAGMA WALL MWFL Type

Field Arrangement

X

Y

Mounting height

1st luminaire (X/Y/Z) 0.489 m, 2.301 m, 1.900 m

0.489 m

2.301 m

1.900 m

1

X-direction

2 pcs., Center - center, 0.977 m

1.466 m

2.301 m

1.900 m

2

Y-direction

1 pcs., Center - center, 4.603 m

Arrangement

A1

SERVICES AND EQUIPMENT -3

Luminaire

39


illumination model

Building 1 · Storey 1 · toilet 1

Luminaire list Φtotal

Ptotal

Luminous efficacy

6808 lm

140.0 W

48.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

2

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

40


illumination model

Building 1 · Storey 1 · toilet 1

Calculation objects

41


illumination model

Building 1 · Storey 1 · toilet 1

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

127 lx

4123 lx

0.17

0.031

Index

(Target) Workplane (toilet 1) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

753 lx (≥ 500 lx)

S4

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

42


illumination model

Building 1 · Storey 1 · toilet 1

Workplane (toilet 1)

Properties

Ē

Emin

Emax

g1

g2

127 lx

4123 lx

0.17

0.031

Index

(Target) Workplane (toilet 1) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

753 lx (≥ 500 lx)

S4

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

43


illumination model

Building 1 · Storey 1 · toilet 2

Summary

Ground area: 9.00 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 1.900 m

44


illumination model

Building 1 · Storey 1 · toilet 2

Summary Results Symbol

Calculated

Target

Ē

745 lx

≥ 500 lx

g1

0.17

-

Consumption values

Consumption

390 kWh/a

max. 350 kWh/a

Lighting power density

Room

15.56 W/m²

-

-

2.09 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

2

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

45


illumination model

Building 1 · Storey 1 · toilet 2

Luminaire layout plan

46


illumination model

Building 1 · Storey 1 · toilet 2

Luminaire layout plan

Manufacturer

TARGETTI

Article No.

1T2289N+1T2559N

Article name

MAGMA WALL MWFL

2 x Targetti Sankey S.p.A. MAGMA WALL MWFL Type

Field Arrangement

X

Y

Mounting height

1st luminaire (X/Y/Z) 0.489 m, 2.301 m, 1.900 m

0.489 m

2.301 m

1.900 m

1

X-direction

2 pcs., Center - center, 0.977 m

1.466 m

2.301 m

1.900 m

2

Y-direction

1 pcs., Center - center, 4.603 m

Arrangement

A1

SERVICES AND EQUIPMENT -3

Luminaire

47


illumination model

Building 1 · Storey 1 · toilet 2

Luminaire list Φtotal

Ptotal

Luminous efficacy

6808 lm

140.0 W

48.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

2

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

48


illumination model

Building 1 · Storey 1 · toilet 2

Calculation objects

49


illumination model

Building 1 · Storey 1 · toilet 2

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

128 lx

4098 lx

0.17

0.031

Index

(Target) Workplane (toilet 2) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

745 lx (≥ 500 lx)

S6

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

50


illumination model

Building 1 · Storey 1 · toilet 2

Workplane (toilet 2)

Properties

Ē

Emin

Emax

g1

g2

128 lx

4098 lx

0.17

0.031

Index

(Target) Workplane (toilet 2) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

745 lx (≥ 500 lx)

S6

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

51


illumination model

Building 1 · Storey 1 · Room 4

Summary

Ground area: 1.24 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.800 m | Mounting height: 1.900 m

52


illumination model

Building 1 · Storey 1 · Room 4

Summary Results Symbol

Calculated

Target

Ē

2257 lx

≥ 500 lx

g1

0.20

-

Consumption values

Consumption

190 kWh/a

max. 50 kWh/a

Lighting power density

Room

56.55 W/m²

-

-

2.51 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

53


illumination model

Building 1 · Storey 1 · Room 4

Luminaire layout plan

54


illumination model

Building 1 · Storey 1 · Room 4

Luminaire layout plan

Manufacturer

TARGETTI

Article No.

1T2289N+1T2559N

Article name

MAGMA WALL MWFL

1 x Targetti Sankey S.p.A. MAGMA WALL MWFL Type

Field Arrangement

1st luminaire (X/Y/Z) 0.592 m, 0.522 m, 1.900 m X-direction

1 pcs., Center - center, 1.185 m

Y-direction

1 pcs., Center - center, 1.045 m

Arrangement

A1

SERVICES AND EQUIPMENT -3

X

Y

Mounting height

0.592 m

0.522 m

1.900 m

Luminaire

1

55


illumination model

Building 1 · Storey 1 · Room 4

Luminaire list Φtotal

Ptotal

Luminous efficacy

3404 lm

70.0 W

48.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

56


illumination model

Building 1 · Storey 1 · Room 4

Calculation objects

57


illumination model

Building 1 · Storey 1 · Room 4

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

449 lx

4111 lx

0.20

0.11

Index

(Target) Workplane (Room 4) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

2257 lx (≥ 500 lx)

S8

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

58


illumination model

Building 1 · Storey 1 · Room 4

Workplane (Room 4)

Properties

Ē

Emin

Emax

g1

g2

449 lx

4111 lx

0.20

0.11

Index

(Target) Workplane (Room 4) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

2257 lx (≥ 500 lx)

S8

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

59


illumination model

Building 1 · Storey 1 · closet 4

Summary

Ground area: 1.44 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 1.900 m

60


illumination model

Building 1 · Storey 1 · closet 4

Summary Results Symbol

Calculated

Target

Ē

2017 lx

≥ 500 lx

g1

0.17

-

Consumption values

Consumption

190 kWh/a

max. 100 kWh/a

Lighting power density

Room

48.53 W/m²

-

-

2.41 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

61


illumination model

Building 1 · Storey 1 · closet 4

Luminaire layout plan

62


illumination model

Building 1 · Storey 1 · closet 4

Luminaire layout plan

Manufacturer

TARGETTI

Article No.

1T2289N+1T2559N

Article name

MAGMA WALL MWFL

1 x Targetti Sankey S.p.A. MAGMA WALL MWFL Type

Field Arrangement

1st luminaire (X/Y/Z) 0.592 m, 0.609 m, 1.900 m X-direction

1 pcs., Center - center, 1.185 m

Y-direction

1 pcs., Center - center, 1.218 m

Arrangement

A1

SERVICES AND EQUIPMENT -3

X

Y

Mounting height

0.592 m

0.609 m

1.900 m

Luminaire

1

63


illumination model

Building 1 · Storey 1 · closet 4

Luminaire list Φtotal

Ptotal

Luminous efficacy

3404 lm

70.0 W

48.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

64


illumination model

Building 1 · Storey 1 · closet 4

Calculation objects

65


illumination model

Building 1 · Storey 1 · closet 4

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

345 lx

4076 lx

0.17

0.085

S10

(Target) Workplane (closet 4) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

2017 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

66


illumination model

Building 1 · Storey 1 · closet 4

Workplane (closet 4)

Properties

Ē

Emin

Emax

g1

g2

Index

345 lx

4076 lx

0.17

0.085

S10

(Target) Workplane (closet 4) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

2017 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

67


illumination model

Building 1 · Storey 1 · closet 5

Summary

Ground area: 1.29 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 2.470 m

68


illumination model

Building 1 · Storey 1 · closet 5

Summary Results Symbol

Calculated

Target

Ē

1242 lx

≥ 500 lx

g1

0.89

-

Consumption values

Consumption

120 kWh/a

max. 50 kWh/a

Lighting power density

Room

33.06 W/m²

-

-

2.66 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

ETAP

42.7 W

4552 lm

106.6 lm/W

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

69


illumination model

Building 1 · Storey 1 · closet 5

Luminaire layout plan

70


illumination model

Building 1 · Storey 1 · closet 5

Luminaire layout plan

Manufacturer

ETAP

Article No.

R728/LEDN3645SX1

Article name

Individual luminaires X

Y

Mounting height

0.576 m

0.565 m

2.470 m

SERVICES AND EQUIPMENT -3

Luminaire

1

71


illumination model

Building 1 · Storey 1 · closet 5

Luminaire list Φtotal

Ptotal

Luminous efficacy

4552 lm

42.7 W

106.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

ETAP

42.7 W

4552 lm

106.6 lm/W

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

72


illumination model

Building 1 · Storey 1 · closet 5

Calculation objects

73


illumination model

Building 1 · Storey 1 · closet 5

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

1105 lx

1312 lx

0.89

0.84

S12

(Target) Workplane (closet 5) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1242 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

74


illumination model

Building 1 · Storey 1 · closet 5

Workplane (closet 5)

Properties

Ē

Emin

Emax

g1

g2

Index

1105 lx

1312 lx

0.89

0.84

S12

(Target) Workplane (closet 5) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1242 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

75


illumination model

Building 1 · Storey 1 · living and dining

Summary

Ground area: 92.94 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 2.400 m

76


illumination model

Building 1 · Storey 1 · living and dining

Summary Results Symbol

Calculated

Target

Ē

416 lx

≥ 500 lx

g1

0.041

-

Consumption values

Consumption

[1200 - 1350] kWh/a

max. 3300 kWh/a

Lighting power density

Room

5.20 W/m²

-

-

1.25 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

21

Disano

23.0 W

2070 lm

90.0 lm/W

SERVICES AND EQUIPMENT -3

Eco Lex 3

Fosnova Eco Lex 3 3000K CLD CELL-DI white

77


illumination model

Building 1 · Storey 1 · living and dining

Luminaire layout plan

78


illumination model

Building 1 · Storey 1 · living and dining

Luminaire layout plan

Manufacturer

Disano

Article No.

Eco Lex 3

Article name

Fosnova Eco Lex 3 3000K CLD CELL-DI white

21 x Disano Illuminazione Fosnova Eco Lex 3 3000K CLD CELL-DI white Type

X

Y

Mounting height

1st luminaire (X/Y/Z) 15.512 m, 9.204 m, 2.400 m

15.512 m

9.204 m

2.400 m

1

X-direction

13.443 m

9.204 m

2.400 m

2

11.375 m

9.204 m

2.400 m

3

9.307 m

9.204 m

2.400 m

4

15.512 m

7.530 m

2.400 m

5

13.443 m

7.530 m

2.400 m

6

11.375 m

7.530 m

2.400 m

7

9.307 m

7.530 m

2.400 m

8

13.443 m

5.857 m

2.400 m

9

11.375 m

5.857 m

2.400 m

10

13.443 m

4.184 m

2.400 m

11

11.375 m

4.184 m

2.400 m

12

13.443 m

2.510 m

2.400 m

13

Y-direction

Arrangement

Field Arrangement

8 pcs., Center - center, Distances not equal

6 pcs., Center - center, Distances not equal

A1

SERVICES AND EQUIPMENT -3

Luminaire

79


illumination model

Building 1 · Storey 1 · living and dining

Luminaire layout plan

SERVICES AND EQUIPMENT -3

X

Y

Mounting height

Luminaire

11.375 m

2.510 m

2.400 m

14

13.443 m

0.837 m

2.400 m

15

11.375 m

0.837 m

2.400 m

16

7.239 m

7.530 m

2.400 m

17

7.239 m

4.184 m

2.400 m

18

5.171 m

4.184 m

2.400 m

19

3.102 m

4.184 m

2.400 m

20

1.034 m

4.184 m

2.400 m

21

80


illumination model

Building 1 · Storey 1 · living and dining

Luminaire list Φtotal

Ptotal

Luminous efficacy

43470 lm

483.0 W

90.0 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

21

Disano

23.0 W

2070 lm

90.0 lm/W

SERVICES AND EQUIPMENT -3

Eco Lex 3

Fosnova Eco Lex 3 3000K CLD CELL-DI white

81


illumination model

Building 1 · Storey 1 · living and dining

Calculation objects

82


illumination model

Building 1 · Storey 1 · living and dining

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

16.9 lx

723 lx

0.041

0.023

S14

(Target) Workplane (living and dining) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

416 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

83


illumination model

Building 1 · Storey 1 · living and dining

Workplane (living and dining)

Properties

Ē

Emin

Emax

g1

g2

Index

16.9 lx

723 lx

0.041

0.023

S14

(Target) Workplane (living and dining) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

416 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

84


illumination model

Building 1 · Storey 1 · closet 6

Summary

Ground area: 1.84 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 1.900 m

85


illumination model

Building 1 · Storey 1 · closet 6

Summary Results Symbol

Calculated

Target

Ē

1611 lx

≥ 500 lx

g1

0.15

-

Consumption values

Consumption

190 kWh/a

max. 100 kWh/a

Lighting power density

Room

38.04 W/m²

-

-

2.36 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

86


illumination model

Building 1 · Storey 1 · closet 6

Luminaire layout plan

87


illumination model

Building 1 · Storey 1 · closet 6

Luminaire layout plan

Manufacturer

TARGETTI

Article No.

1T2289N+1T2559N

Article name

MAGMA WALL MWFL

1 x Targetti Sankey S.p.A. MAGMA WALL MWFL Type

Field Arrangement

1st luminaire (X/Y/Z) 0.578 m, 0.796 m, 1.900 m X-direction

1 pcs., Center - center, 1.156 m

Y-direction

1 pcs., Center - center, 1.592 m

Arrangement

A1

SERVICES AND EQUIPMENT -3

X

Y

Mounting height

0.578 m

0.796 m

1.900 m

Luminaire

1

88


illumination model

Building 1 · Storey 1 · closet 6

Luminaire list Φtotal

Ptotal

Luminous efficacy

3404 lm

70.0 W

48.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

89


illumination model

Building 1 · Storey 1 · closet 6

Calculation objects

90


illumination model

Building 1 · Storey 1 · closet 6

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

244 lx

4032 lx

0.15

0.061

S16

(Target) Workplane (closet 6) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1611 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

91


illumination model

Building 1 · Storey 1 · closet 6

Workplane (closet 6)

Properties

Ē

Emin

Emax

g1

g2

Index

244 lx

4032 lx

0.15

0.061

S16

(Target) Workplane (closet 6) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1611 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

92


illumination model

Building 1 · Storey 1 · closet 1

Summary

Ground area: 4.29 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 2.400 m

93


illumination model

Building 1 · Storey 1 · closet 1

Summary Results Symbol

Calculated

Target

Ē

699 lx

≥ 500 lx

g1

0.53

-

Consumption values

Consumption

120 kWh/a

max. 200 kWh/a

Lighting power density

Room

9.96 W/m²

-

-

1.42 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

ETAP

42.7 W

4552 lm

106.6 lm/W

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

94


illumination model

Building 1 · Storey 1 · closet 1

Luminaire layout plan

95


illumination model

Building 1 · Storey 1 · closet 1

Luminaire layout plan

Manufacturer

ETAP

Article No.

R728/LEDN3645SX1

Article name

1 x ETAP R728/LEDN3645SX1 Type

Field Arrangement

1st luminaire (X/Y/Z) 1.463 m, 0.733 m, 2.400 m X-direction

1 pcs., Center - center, 2.925 m

Y-direction

1 pcs., Center - center, 1.466 m

Arrangement

A1

SERVICES AND EQUIPMENT -3

X

Y

Mounting height

1.463 m

0.733 m

2.400 m

Luminaire

1

96


illumination model

Building 1 · Storey 1 · closet 1

Luminaire list Φtotal

Ptotal

Luminous efficacy

4552 lm

42.7 W

106.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

ETAP

42.7 W

4552 lm

106.6 lm/W

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

97


illumination model

Building 1 · Storey 1 · closet 1

Calculation objects

98


illumination model

Building 1 · Storey 1 · closet 1

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

368 lx

929 lx

0.53

0.40

S18

(Target) Workplane (closet 1) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

699 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

99


illumination model

Building 1 · Storey 1 · closet 1

Workplane (closet 1)

Properties

Ē

Emin

Emax

g1

g2

Index

368 lx

929 lx

0.53

0.40

S18

(Target) Workplane (closet 1) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

699 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

100


illumination model

Building 1 · Storey 1 · bedroom 3

Summary

Ground area: 18.82 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 2.400 m

101


illumination model

Building 1 · Storey 1 · bedroom 3

Summary Results Symbol

Calculated

Target

Ē

744 lx

≥ 500 lx

g1

0.55

-

Consumption values

Consumption

[300 - 470] kWh/a

max. 700 kWh/a

Lighting power density

Room

9.07 W/m²

-

-

1.22 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

4

ETAP

42.7 W

4552 lm

106.6 lm/W

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

102


illumination model

Building 1 · Storey 1 · bedroom 3

Luminaire layout plan

103


illumination model

Building 1 · Storey 1 · bedroom 3

Luminaire layout plan

Manufacturer

ETAP

Article No.

R728/LEDN3645SX1

Article name

2 x ETAP R728/LEDN3645SX1 Type

Field Arrangement

X

Y

Mounting height

Luminaire

1st luminaire (X/Y/Z) 1.133 m, 2.825 m, 2.400 m

1.133 m

2.825 m

2.400 m

1

X-direction

3 pcs., Center - center, Distances not equal

4.202 m

2.825 m

2.400 m

2

Y-direction

1 pcs., Center - center, Distances not equal

Arrangement

A1

X

Y

Mounting height

1st luminaire (X/Y/Z) 1.137 m, 0.604 m, 2.400 m

1.137 m

0.604 m

2.400 m

3

X-direction

4.206 m

0.604 m

2.400 m

4

2 x ETAP R728/LEDN3645SX1 Type

Field Arrangement

3 pcs., Center - center, Distances not equal

SERVICES AND EQUIPMENT -3

Luminaire

104


illumination model

Building 1 · Storey 1 · bedroom 3

Luminaire layout plan Y-direction

1 pcs., Center - center, Distances not equal

Arrangement

A2

SERVICES AND EQUIPMENT -3

105


illumination model

Building 1 · Storey 1 · bedroom 3

Luminaire list Φtotal

Ptotal

Luminous efficacy

18208 lm

170.8 W

106.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

4

ETAP

42.7 W

4552 lm

106.6 lm/W

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

106


illumination model

Building 1 · Storey 1 · bedroom 3

Calculation objects

107


illumination model

Building 1 · Storey 1 · bedroom 3

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

406 lx

977 lx

0.55

0.42

S20

(Target) Workplane (bedroom 3) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

744 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

108


illumination model

Building 1 · Storey 1 · bedroom 3

Workplane (bedroom 3)

Properties

Ē

Emin

Emax

g1

g2

Index

406 lx

977 lx

0.55

0.42

S20

(Target) Workplane (bedroom 3) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

744 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

109


illumination model

Building 1 · Storey 1 · closet 3

Summary

Ground area: 2.59 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 1.900 m

110


illumination model

Building 1 · Storey 1 · closet 3

Summary Results Symbol

Calculated

Target

Ē

1201 lx

≥ 500 lx

g1

0.13

-

Consumption values

Consumption

190 kWh/a

max. 100 kWh/a

Lighting power density

Room

27.03 W/m²

-

-

2.25 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

111


illumination model

Building 1 · Storey 1 · closet 3

Luminaire layout plan

112


illumination model

Building 1 · Storey 1 · closet 3

Luminaire layout plan

Manufacturer

TARGETTI

Article No.

1T2289N+1T2559N

Article name

MAGMA WALL MWFL

1 x Targetti Sankey S.p.A. MAGMA WALL MWFL Type

Field Arrangement

1st luminaire (X/Y/Z) 0.766 m, 0.846 m, 1.900 m X-direction

1 pcs., Center - center, 1.531 m

Y-direction

1 pcs., Center - center, 1.691 m

Arrangement

A1

SERVICES AND EQUIPMENT -3

X

Y

Mounting height

0.766 m

0.846 m

1.900 m

Luminaire

1

113


illumination model

Building 1 · Storey 1 · closet 3

Luminaire list Φtotal

Ptotal

Luminous efficacy

3404 lm

70.0 W

48.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

114


illumination model

Building 1 · Storey 1 · closet 3

Calculation objects

115


illumination model

Building 1 · Storey 1 · closet 3

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

157 lx

3954 lx

0.13

0.040

S22

(Target) Workplane (closet 3) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1201 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

116


illumination model

Building 1 · Storey 1 · closet 3

Workplane (closet 3)

Properties

Ē

Emin

Emax

g1

g2

Index

157 lx

3954 lx

0.13

0.040

S22

(Target) Workplane (closet 3) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1201 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

117


illumination model

Building 1 · Storey 1 · bedroom 1

Summary

Ground area: 18.53 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 2.400 m

118


illumination model

Building 1 · Storey 1 · bedroom 1

Summary Results Symbol

Calculated

Target

Ē

760 lx

≥ 500 lx

g1

0.56

-

Consumption values

Consumption

[430 - 470] kWh/a

max. 650 kWh/a

Lighting power density

Room

9.22 W/m²

-

-

1.21 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

4

ETAP

42.7 W

4552 lm

106.6 lm/W

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

119


illumination model

Building 1 · Storey 1 · bedroom 1

Luminaire layout plan

120


illumination model

Building 1 · Storey 1 · bedroom 1

Luminaire layout plan

Manufacturer

ETAP

Article No.

R728/LEDN3645SX1

Article name

2 x ETAP R728/LEDN3645SX1 Type

Field Arrangement

X

Y

Mounting height

Luminaire

1st luminaire (X/Y/Z) 0.913 m, 2.970 m, 2.400 m

0.913 m

2.970 m

2.400 m

1

X-direction

3 pcs., Center - center, Distances not equal

3.982 m

2.970 m

2.400 m

2

Y-direction

1 pcs., Center - center, Distances not equal

Arrangement

A1

X

Y

Mounting height

1st luminaire (X/Y/Z) 0.875 m, 0.567 m, 2.400 m

0.875 m

0.567 m

2.400 m

3

X-direction

3.944 m

0.567 m

2.400 m

4

2 x ETAP R728/LEDN3645SX1 Type

Field Arrangement

3 pcs., Center - center, Distances not equal

SERVICES AND EQUIPMENT -3

Luminaire

121


illumination model

Building 1 · Storey 1 · bedroom 1

Luminaire layout plan Y-direction

1 pcs., Center - center, Distances not equal

Arrangement

A2

SERVICES AND EQUIPMENT -3

122


illumination model

Building 1 · Storey 1 · bedroom 1

Luminaire list Φtotal

Ptotal

Luminous efficacy

18208 lm

170.8 W

106.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

4

ETAP

42.7 W

4552 lm

106.6 lm/W

SERVICES AND EQUIPMENT -3

R728/ LEDN3645

123


illumination model

Building 1 · Storey 1 · bedroom 1

Calculation objects

124


illumination model

Building 1 · Storey 1 · bedroom 1

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

429 lx

990 lx

0.56

0.43

S24

(Target) Workplane (bedroom 1) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

760 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

125


illumination model

Building 1 · Storey 1 · bedroom 1

Workplane (bedroom 1)

Properties

Ē

Emin

Emax

g1

g2

Index

429 lx

990 lx

0.56

0.43

S24

(Target) Workplane (bedroom 1) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

760 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

126


illumination model

Building 1 · Storey 1 · closet 2

Summary

Ground area: 2.74 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 1.900 m

127


illumination model

Building 1 · Storey 1 · closet 2

Summary Results Symbol

Calculated

Target

Ē

1111 lx

≥ 500 lx

g1

0.14

-

Consumption values

Consumption

190 kWh/a

max. 100 kWh/a

Lighting power density

Room

25.51 W/m²

-

-

2.30 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

128


illumination model

Building 1 · Storey 1 · closet 2

Luminaire layout plan

129


illumination model

Building 1 · Storey 1 · closet 2

Luminaire layout plan

Manufacturer

TARGETTI

Article No.

1T2289N+1T2559N

Article name

MAGMA WALL MWFL

1 x Targetti Sankey S.p.A. MAGMA WALL MWFL Type

Field Arrangement

1st luminaire (X/Y/Z) 0.766 m, 0.896 m, 1.900 m X-direction

1 pcs., Center - center, 1.531 m

Y-direction

1 pcs., Center - center, 1.792 m

Arrangement

A1

SERVICES AND EQUIPMENT -3

X

Y

Mounting height

0.766 m

0.896 m

1.900 m

Luminaire

1

130


illumination model

Building 1 · Storey 1 · closet 2

Luminaire list Φtotal

Ptotal

Luminous efficacy

3404 lm

70.0 W

48.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

1

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

131


illumination model

Building 1 · Storey 1 · closet 2

Calculation objects

132


illumination model

Building 1 · Storey 1 · closet 2

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

151 lx

3938 lx

0.14

0.038

S26

(Target) Workplane (closet 2) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1111 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

133


illumination model

Building 1 · Storey 1 · closet 2

Workplane (closet 2)

Properties

Ē

Emin

Emax

g1

g2

Index

151 lx

3938 lx

0.14

0.038

S26

(Target) Workplane (closet 2) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

1111 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

134


illumination model

Building 1 · Storey 1 · Room 14

Summary

Ground area: 1.17 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m |

135


illumination model

Building 1 · Storey 1 · Room 14

Summary Results Symbol

Calculated

Target

Ē

0.00 lx

≥ 500 lx

g1

-

-

Consumption values

Consumption

0 kWh/a

max. 50 kWh/a

Lighting power density

Room

0.00 W/m²

-

Workplane

Check

-

-

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

136


illumination model

Building 1 · Storey 1 · Room 14

Calculation objects

137


illumination model

Building 1 · Storey 1 · Room 14

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

0.00 lx

0.00 lx

-

-

S28

(Target) Workplane (Room 14) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

0.00 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

138


illumination model

Building 1 · Storey 1 · Room 14

Workplane (Room 14)

Properties

Ē

Emin

Emax

g1

g2

Index

0.00 lx

0.00 lx

-

-

S28

(Target) Workplane (Room 14) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

0.00 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

139


illumination model

Building 1 · Storey 1 · porch

Summary

Ground area: 12.06 m² | Reflection factors: Ceiling: 70.0 %, Walls: 75.2 %, Floor: 40.3 % | Light loss factor: 0.80 (fixed) | Clearance height: 2.470 m | Mounting height: 1.900 m

140


illumination model

Building 1 · Storey 1 · porch

Summary Results Symbol

Calculated

Target

Ē

515 lx

≥ 500 lx

g1

0.091

-

Consumption values

Consumption

390 kWh/a

max. 450 kWh/a

Lighting power density

Room

11.61 W/m²

-

-

2.26 W/m²/100 lx

-

-

Workplane

Check

-

Utilisation profile: DIALux presetting, Standard (office)

Luminaire list pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

2

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

141


illumination model

Building 1 · Storey 1 · porch

Luminaire layout plan

142


illumination model

Building 1 · Storey 1 · porch

Luminaire layout plan

Manufacturer

TARGETTI

Article No.

1T2289N+1T2559N

Article name

MAGMA WALL MWFL

2 x Targetti Sankey S.p.A. MAGMA WALL MWFL Type

Field Arrangement

X

Y

Mounting height

1st luminaire (X/Y/Z) 1.688 m, 0.896 m, 1.900 m

1.688 m

0.896 m

1.900 m

1

X-direction

2 pcs., Center - center, 3.376 m

5.064 m

0.896 m

1.900 m

2

Y-direction

1 pcs., Center - center, 1.792 m

Arrangement

A1

SERVICES AND EQUIPMENT -3

Luminaire

143


illumination model

Building 1 · Storey 1 · porch

Luminaire list Φtotal

Ptotal

Luminous efficacy

6808 lm

140.0 W

48.6 lm/W

pcs.

Manufacturer Article No. Article name

P

Φ

Luminous efficacy

2

TARGETTI

70.0 W

3404 lm

48.6 lm/W

SERVICES AND EQUIPMENT -3

1T2289N +1T2559N

MAGMA WALL MWFL

144


illumination model

Building 1 · Storey 1 · porch

Calculation objects

145


illumination model

Building 1 · Storey 1 · porch

Calculation objects Work planes Properties

Ē

Emin

Emax

g1

g2

Index

47.0 lx

3905 lx

0.091

0.012

S30

(Target) Workplane (porch) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

515 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

146


illumination model

Building 1 · Storey 1 · porch

Workplane (porch)

Properties

Ē

Emin

Emax

g1

g2

Index

47.0 lx

3905 lx

0.091

0.012

S30

(Target) Workplane (porch) Perpendicular illuminance (adaptive) Height: 0.800 m, Wall zone: 0.000 m

515 lx (≥ 500 lx)

Utilisation profile: DIALux presetting, Standard (office)

SERVICES AND EQUIPMENT -3

147


illumination model

Glossary A A

Formula symbol for a surface in the geometry

B Background area

The background area borders the direct ambient area according to DIN EN 12464-1 and reaches up to the borders of the room. In larger rooms, the background area is at least 3 m wide. It is located horizontally at floor level.

C CCT

(Engl. correlated color temperature) Body temperature of a thermal radiator that serves to describe its light color. Unit: Kelvin [K]. The lesser the numerical value the redder; the greater the numerical value the bluer the light color. The color temperature of gas-discharge lamps and semi-conductors are termed "correlated color temperature" in contrast to the color temperature of thermal radiators. Allocation of the light colors to the color temperature ranges acc. to EN 12464-1: Light color - color temperature [K] warm white (ww) < 3,300 K neutral white (nw) ≥ 3,300 – 5,300 K daylight white (dw) > 5.300 K

Clearance height

The designation for the distance between upper edge of the floor and bottom edge of the ceiling (in the completely furnished status of room).

CRI

(Engl. color rendering index) Designation for the color rendering index of a luminaire or a lamp acc. to DIN 6169: 1976 or CIE 13.3: 1995. The general color rendering index Ra (or CRI) is a dimensionless figure that describes the quality of a white light source in regards to its similarity with the remission spectra of defined 8 test colors (see DIN 6169 or CIE 1974) to a reference light source.

D Daylight factor

Ratio of the illuminance achieved solely by daylight incidence at a point in the inside to the horizontal illuminance in the outer area under an unobstructed sky. Formula symbol: D (Engl. daylight factor) Unit: %

148


illumination model

Glossary Daylight quotient effective area

A calculation surface within which the daylight quotient is calculated.

E Eta (η)

(light output ratio) The light output ratio describes what percentage of the luminous flux of a free radiating lamp (or LED module) is emitted by the luminaire when installed. Unit: %

G g1

Often also Uo (Engl. overall uniformity) Designates the overall uniformity of the illuminance on a surface. It is the quotient from Emin to Ē and is required, for instance, in standards for illumination of workstations.

g2

Actually it designates the "non-uniformity" of the illuminance on a surface. It is the quotient of Emin to Emax and is generally only relevant for certifying the emergency lighting acc. to EN 1838.

Illuminance

Describes the ratio of the luminous flux that strikes a certain surface to the size of this surface (lm/m² = lx). The illuminance is not tied to an object surface. It can be determined anywhere in space (inside or outside). The illuminance is not a product feature because it is a recipient value. Luxometers are used for measuring.

I

Unit: Lux Abbreviation: lx Formula symbol: E Illuminance, adaptive

For the determining of the middle adaptive illuminance on a surface, this is rastered "adaptively". In the area of large illuminance differences within the surface, the raster is subdivided finer; within lesser differences, a rougher classification is made.

Illuminance, horizontal

Illuminance that is calculated or measured on a horizontal (level) surface (this can be for example a table top or the floor). The horizontal illuminance is usually identified by the formula letter Eh.

Illuminance, perpendicular

Illuminance that is calculated or measured plumb-vertical to a surface. This needs to be taken into account for tilted surfaces. If the surface is horizontal or vertical, then there is no difference between the perpendicular and the horizontal or vertical illuminance.

149


illumination model

Glossary Illuminance, vertical

Illuminance that is calculated or measured on a vertical surface (this can be for example the front of some shelves). The vertical illuminance is usually identified by the formula letter Ev.

L LENI

(Engl. lighting energy numeric indicator) Lighting energy numeric indicator acc. to EN 15193 Unit: kWh/m² year

Light loss factor

See MF

LLMF

(Engl. lamp lumen maintenance factor)/acc. to CIE 97: 2005 Lamp flux maintenance factor that takes the luminous flux reduction into account of a luminaire or an LED module in the course of the operating time. The lamp flux maintenance factor is specified as a decimal digit and can have a maximum value of 1 (no luminous flux reduction existing).

LMF

(Engl. luminaire maintenance factor)/acc. to CIE 97: 2005 Luminaire maintenance factor that takes the soiling into account of the luminaire in the course of the operating time. The luminaire maintenance factor is specified as a decimal digit and can have a maximum value of 1 (no soiling existing).

LSF

(Engl. lamp survival factor)/acc. to CIE 97: 2005 Lamp survival factor that takes the total failure into account of a luminaire in the course of the operating time. The lamp survival factor is specified as a decimal digit and can have a maximum value of 1 (no failures existing within the time concerned or prompt replacement after the failure).

Luminance

Dimension for the "brightness impression" that the human eye has of a surface. The surface itself can emit light thereby or light striking it can be reflected (emitter value). It is the only photometric value that the human eye can perceive. Unit: Candela per square meter Abbreviation: cd/m² Formula symbol: L

Luminous efficacy

Ratio of the emitted luminous flux Φ [lm] to the absorbed electrical power P [W] Unit: lm/ W. This ratio can be formed for the lamp or LED module (lamp or module light output), the lamp or module with control gear (system light output) and the complete luminaire (luminaire light output).

150


illumination model

Glossary Luminous flux

Dimension for the total light output that is emitted from one light source in all directions. It is thus an "emitter value" that specifies the entire emitting output. The luminous flux of a light source can only be determined in a laboratory. A difference is made between the lamp or LED module luminous flux and the luminaire luminous flux. Unit: Lumen Abbreviation: lm Formula symbol: Φ

Luminous intensity

Describes the intensity of the light in a certain direction (emitter value). The luminous intensity is a matter of the luminous flux Φ that is emitted in a certain spherical angle Ω. The radiation characteristics of a light source are presented graphically in a light distribution curve (LDC). The luminous intensity is an SI base unit. Unit: Candela Abbreviation: cd Formula symbol: I

M MF

(Engl. maintenance factor)/acc. to CIE 97: 2005 Maintenance factor as decimal number between 0 and 1 that describes the ratio of the new value of a photometric planning parameter (e.g. of the illuminance) to a maintenance value after a certain time. The maintenance factor takes into account the soiling of luminaires and rooms as well as the luminous flux reduction and the failure of light sources. The maintenance factor is taken into account either overall or determined in detail acc. to CIE 97: 2005 by the formula RMF x LMF x LLMF x LSF.

P P

(Engl. power) Electric power consumption Unit: watt Abbreviation: W

R Reflection factor

The reflection degree of a surface describes how much of the striking light is reflected back. The reflection degree is defined by the color of the surface.

151


illumination model

Glossary RMF

(Engl. room surface maintenance factor)/acc. to CIE 97: 2005 Room surface maintenance factor that takes the soiling into account of the space encompassing surfaces in the course of the operating time. The room surface maintenance factor is specified as a decimal digit and can have a maximum value of 1 (no soiling existing).

S Surrounding area

The ambient area directly borders the area of the visual task and should be planned with a width of at least 0.5 m according to DIN EN 12464-1. It is at the same height as the area of the visual task.

U UGR (max)

(unified glare rating) Measure for the psychological glare effect in interiors. In addition to luminaire luminance, the UGR value also depends on the position of the observer, the viewing direction and the ambient luminance. Among other things, EN 12464-1 specifies maximum permissible UGR values for various indoor workplaces.

UGR observer

Calculation point in the room, for the DIALux the UGR value is determined. The location and height of the calculation point should correspond to the typical observer position (position and eye level of the user).

V Visual task area

The area that is needed for carrying out the visual task in accordance with DIN EN 12464-1. The height corresponds with the height at which the visual task is executed.

W Wall zone

Circumferential area between working plane and walls that is not taken into account for the calculation.

Workplane

Virtual measuring or calculation surface at the height of the visual task that generally follows the room geometry. The working plane may also feature a wall zone.

152


Turn static files into dynamic content formats.

Create a flipbook