GAS BOILERS
ADI HT ADI LT ADI CD
THE INTELLIGENT CHOICE • BEST EFFICIENCY • SPEEDY RETURN ON INVESTMENT • HIGH RESISTANCE TO LIMESCALE • EXTREMELY EASY TO INSTALL • MINIMUM SPACE
ADI boilers from ADISA Calefacción, bespoke solutions to new needs of the ENERGY SAVINGS. A REQUIREMENT. •A round 80% of the energy that is consumed in the EU comes from fossil fuels. A significant and growing proportion of this comes from outside the EU. Dependence on imported oil and gas, which now stands at around 50%, could rise to 70% by 2030. •A ccording to statistics published by the European Union, Europeans spend an average of 90% of our lives inside buildings. Perhaps that is why the energy consumed in buildings accounts for 40% of all the energy consumed in Europe. • In addition, heating and hot water account for between 60% and 75% of household energy expenditure.
ADISA SOLUTION. BEST EFFICIENCY IN THE EUROPEAN MARKET. The ADI range of boilers offers the best efficiency in the market in each model: • With ADI boilers, which are EC certified with stars and stars, you get the best energy profit, along with the lowest energy losses thanks to their compact size.
ECOLOGY AND RESPECT FOR THE ENVIRONMENT. A PRIORITY. •C arbon dioxide (CO2) is one of the greenhouse gases that remain the longest in the atmosphere. Also, and in accordance with IEO2007, predicted CO2 emissions are 33.9 billion tons in 2015 and 42.9 in 2030. •T his is why the European campaign known as “20-20-20 in 2020” has been created, with the aim, among others, of cutting carbon dioxide emissions by 20% by 2020.
ADISA SOLUTION = ECOLOGICAL COMBUSTION. • The ADI range of boilers use ecological combustion class NOx = 5. • Their emission of pollutants is minimal, less than 10 ppm of NOx. • Even with a certified efficiency of and stars, the ADI range has a CO2 emission of around 20% less than a traditional boiler.
WHAT ARE WE LOOKING FOR? • The most balanced options in quality, price and efficiency.
ADISA SOLUTION. SPEEDY AMORTISATION OF THE INVESTMENT. • The small dimensions and weight of the ADI range of boilers favour space savings and aid installation. • Their high energy efficiency also ensures a speedy return on investment.
MARKET
twenty-first century ABOUT THE IMPORTANCE OF GAS.
Environmental impact
There are many reasons justifying the use of natural gas over other forms of energy, so much so that gas is seen as the favourite energy source on the 2025 horizon: Environmental reasons: Natural gas cuts the emission of polluting particles by 54%.
Fuel oil: Standard mixed boiler
Natural gas: Standard mixed boiler
Electricity: Heat pump + thermo
Natural gas: Condensing boiler
2,500
Technical reasons: • As it is a continuous supply energy, there is no need for all the controls and maintenance required by a storage tank. • As it is a cleaner fuel, gas cuts maintenance costs, so improving operating costs. • Gas installations offer maximum safety guarantees.
2,047 2,000 1,572 1,500
1,294 934
1,000
Financial reasons: The price difference between gas and other forms of energy ensures a speedy amortisation of the installation. Also, its price stability prevents surprises in the future.
500
0 kg CO2 / year OCU-2009
36 30 24 18 12 6 0 -6
Ju ly Au Se gus t pt em be Oc r to b N ov er em De ber ce m be r
Average monthly temp. Temp. at 7am Average temp. at 1pm Temp. at 6pm Absolute maximum temp. Absolute minimum temp.
Ap ril M ay Ju ne
• Thanks to modulating technology, ADISA Calefacción’s ADI boilers maintain a gradual temperature variation, also achieving a gradual consumption.
Heating cut-off temperature 42 Temperature (ºC)
• To maintain comfort 365 days a year, it is necessary to adjust the working temperature according to the ups and downs of the different seasons, without causing sharp changes in consumption.
Real demand of buildings European capital
Ja nu a Fe ry br ua ry M ar ch
ADI COMFORT.
Heating design temperature
HIGH RESISTANCE TO THE DIFFERENT WATER QUALITIES. •A DISA Calefacción has taken one step further with the design and concept of the new hydraulic circuit of the ADI range, providing high resistance to limescale and maintaining optimum heat exchanges.
ADI RANGE
3
ADI boilers from ADISA Calefacci贸n, features, qualities and technology with MAXIMUM Efficiency. Efficiency far above the market average throughout the whole range guarantees a speedy amortisation.
VERY HIGH EFFICIENCY
LOW TEMPERATURE
CONDENSATION
97%
104%
108%
EC CERTIFIED
EC CERTIFIED
EC CERTIFIED
ADI HT
ADI LT
ADI CD
ref. to LCV
ref. to LCV
seasonal eff.
MAXIMUM ENERGY EFFICIENCY MINIMUM COST
TECHNOLOGICAL INNOVATION
GREATER RESISTANCE TO LIMESTONE MINIMUM SPACE MAXIMUM EASE OF INSTALLATION BUILT-IN BURNER AND GAS LINES
MODULATION. Planned adaptation to the demands of the installation. Thermal demand of the home
Power of the heat generation system
unbeatable results COMPACT DESIGN: MINIMUM AREA TAKEN UP, MINIMUM WEIGHT, MAXIMUM SAVINGS ON INSTALLATION. Comparison of space used in a 1,000 kW boiler room ADI Boiler
ADI RANGE
Pyrotubular type boiler 15.4m2
2,420mm
3,825mm
6.4m2 LT 475
LT 475
4,030mm
Saving of 9m2
2,660mm
• Smaller boiler room: less cost. • Their compact design allows the boiler room to be located on a flat roof, so making the most of space not occupied for other uses. • Aids the reconversion of the boiler room. • All the boilers include a transport base for ease of movement.
Optimised and reduced dimensions. ADI HT
ADI LT
A
105
105
350
130
130
150
150
200
200
250
250
275
275
325
325
400
400
475
475
550
550
650
650
750
750
450
B
C*
ADI CD
A
70
595 615
Ø
1,100
635 660
150
175
120
450
350
400 450
615
200
C
1,100
635
175 250 B
A
660
300 940 1,583
325 810
350
450 550 650
400 1,040 975 1,668
750
* Note: d imensions in mm; height without taking into consideration the increase due to the silent-block feetA supplied with the boiler.
ADI RANGE
Ø 150
175
375
1,040 975 1,668
350
250
940 1,583
C*
595
105
300
810
85
B
C
450
Ø
B
5
Boiler ADI HT Very high efficiency • Exceptional efficiency and energy savings. • EC Certified, star efficiency, from 95 to 97% ref. to LCV. • Power outputs from 104 to 695 kW. • Modulating starting from 30% of the power. Includes “PID” control. • Variable speed fan, air-gas premix venturi, modulating gas valve. • Ecological combustion: class NOx = 5. NOx < 10 ppm, CO around 47 ppm. • Refractory alloy mesh premix burner. • Optimised and reduced dimensions and weights. • Minimum electricity consumption, from 14 W. • Controllable from external station (centralised or telemanaged).
VERY HIGH EFFICIENCY
LOW TEMPERATURE
97%
104%
108
EC CERTIFIED
EC CERTIFIED
EC CERT
ADI HT
ADI LT
ADI
ref. to LCV
ref. to LCV
CONDENS
seasona
MAXIMUM OPERATING Efficiency. Efficiencies according to boiler temperature and for each power curve of the burner
Efficiency ref. to LCV (%)
98
Power:
97
30% 100%
96 95 94 93 92 60
61
62
63
64
65
66
67
68
69
70
Average boiler temperature (ºC)
SPEEDY RETURN ON INVESTMENT. Boiler power output around 350-400 kW. Comparison with standard 2* boiler on the market %
aver. water temp.
%
Burner operation
Annual consumption NG m3/year
ADI HT 3*
High
95.38%
Medium-low
97.10%
Modulating
108,322
Standard 2*
High
92.10%
Medium-low
95.32%
2 stages
115,164
6,842
Annual consumption NG m3/year
In favour of ADI HT Annunal saving gas m3/year
Efficiency at maximum power
Efficiency at minimum power
ADI HT
In favour of ADI HT Annunal saving gas m3/year
aver. water temp.
Boiler Type
Reconversion: comparison with old standard boiler 1* already installed Efficiency at maximum power
Efficiency at minimum power
aver. water temp.
%
aver. water temp.
%
Burner operation
ADI HT 3*
High
95.38%
Medium-low
97.10%
Modulating
108,322
Standard 1*
High
90.40%
Medium-low
89.90%
2 stages
118,068
Boiler Type
9,746
TECHNICAL CHARACTERISTICS. ADI HT
Description Power output Power input
Units
130
150
200
250
275
325
400
475
550
650
750
464
545
616
695
Max. power
kW
104
130
149.3
190
230
262
322
380
Min. power
kW
31.9
40
45.7
58.5
70.3
80.1
98.4
116
141.6 220.8 249.4 281.4
Max. power
kW
109.6
138
157.2
200
242.3
270
334
396
483.3 569.2 643.4
723
m3/h
10.2
12.8
14.6
18.6
22.5
25.1
31
36.8
44.9
67.2
∆T = 10ºC
m3/h
8.9
11.2
12.8
16.3
19.8
22.5
27.7
32.7
39.9
46.9
53
59.8
∆T = 15ºC
m3/h
6
7.5
8.6
10.9
13.2
15
18.5
21.8
26.6
31.2
35.3
39.8
Natural gas flow (G20) at max. power (1) Water flow
105
52.9
59.8
Boiler weight without water
kg
110
112
123
139
330
350
440
445
490
554
579
614
Boiler water capacity
litres
30
30
33
36
76
85
99
106
112
210
210
223
(1) Natural gas LCV= 10.76 kW/m3 Minimum return temperature: 60ºC
ADI RANGE
Maximum operating water pressure: 5 bar Power supply: 230 V, 50 Hz, single phase, Neutral + Earth
7
Boiler ADI LT Low temperature • • • • • •
Exceptional efficiency and energy savings. EC Certified, star efficiency, from 96 to 104% ref. to LCV. Power outputs from 104 to 695 kW. Modulating starting from 30% of the power. Includes “PID” control. Variable speed fan, air-gas premix venturi, modulating gas valve. Boiler heat exchanger in stainless steel. Great resistance to corrosion and high temperature. • No limit of minimum return temperature. • Minimum noise level, from 48.3 dB, with internal soundproof panels. • Minimal electricity consumption, from 14 W. • Ecological combustion, class NOx = 5. NOx < 10 ppm, CO around 47 ppm. • Refractory alloy mesh premix burner. • Optimised and reduced dimensions and weights. • Controllable from external station (centralised or telemanaged).
LOW TEMPERATURE
CONDENSATION
104%
108%
EC CERTIFIED
EC CERTIFIED
ADI LT
ADI CD
ref. to LCV
seasonal eff.
MAXIMUM OPERATING Efficiency. Efficiencies according to burner power
Efficiency ref. to LCV (%)
106
Power:
104
Max. Min.
102 100 98 96 94 35
45
55
65
75
Average boiler temperature (ºC)
SPEEDY RETURN ON INVESTMENT. Boiler power output around 350-400 kW. Comparison with standard 2* boiler on the market Boiler Type
aver. water temp.
%
Burner operation
Annual consumption NG m3/year
96.45%
Low
104.75%
Modulating
105,290
92.86%
Medium-low
96.30%
2 stages
113,808
8,518
Burner operation
Annual consumption NG m3/year
In favour of ADI LT Annunal saving gas m3/year
Efficiency at maximum power aver. water temp.
%
ADI LT 3*
High
Low Temp. 2*
High
Efficiency at minimum power
Reconversion: comparison with old standard boiler 1* already installed Efficiency at maximum power Efficiency at minimum power Boiler Type aver. water temp. % aver. water temp. % ADI LT 3*
High
96.45%
Low
104.75%
Modulating
105,290
Standard 1*
High
90.40%
Medium-low
89.90%
2 stages
118,068
In favour of ADI LT Annunal saving gas m3/year
12,778
TECHNICAL CHARACTERISTICS.
Power output* Power input
Units
130
150
200
250
275
325
400
475
550
650
750
322
380
464
545
616
695
Max. power
kW
104
130
149.3
190
230
262
Min. power
kW
34.4
43.3
49.3
62.8
76
84.8
Max. power
kW
109.6
138
157.2
200
242.3
270
334
396
483.3 569.2 643.4
723
m3/h
10.2
12.8
14.6
18.6
22.5
25.1
31
36.8
44.9
52.9
59.8
67.2
∆T = 10ºC
m /h
8.9
11.2
12.8
16.3
19.8
22.5
27.7
32.7
39.9
46.9
53
59.8
∆T = 15ºC
m /h
Natural gas flow (G20) at max. power (1) Water flow
105
3
104.9 124.4 151.8 237.2 267.7 300.8
6
7.5
8.6
10.9
13.2
15
18.5
21.8
26.6
31.2
35.3
39.8
Boiler weight without water
kg
110
112
123
139
330
350
440
445
490
554
579
614
Boiler water capacity
litres
30
30
33
36
76
85
99
106
112
210
210
223
3
ADI LT
ADI LT
Description
* Power outputs for average water temperature of 70ºC. (1) Natural gas LCV= 10.76 kW/m3 No limit of minimum return temperature
ADI RANGE
Maximum operating water pressure: 5 bar Power supply: 230 V, 50 Hz, single phase, Neutral + Earth
9
Boiler ADI CD Condensation • • • • • •
Exceptional efficiency and energy savings. EC Certified, stars, seasonal efficiency up to 108%. Power outputs from 68 to 675 kW. Modulating starting from 30% of the power. Includes “PID” control. Variable speed fan, air-gas premix venturi, modulating gas valve. Boiler heat exchanger in stainless steel. Great resistance to corrosion and high temperature. • No limit of minimum return temperature. • Minimum noise level, with internal soundproof panels. • Minimal electricity consumption, from 5 W. • Ecological combustion, class NOx = 5. NOx < 10 ppm, CO around 47 ppm. • Refractory alloy mesh premix burner. • Optimised and reduced dimensions and weights. • Controllable from external station (centralised or telemanaged).
CONDENSATION
108% seasonal eff. EC CERTIFIED
ADI CD
The ADI CD boiler and condenSING. •M inimum boiler losses: its compact size guarantees minimum heat losses due to convection and radiation. • Minimum heat losses due to flues temperature.
Latent heat Steam (condensation) ADI HT
Efficiency
ADI LT
Efficiency
ADI CD
Efficiency
Heat losses (flues temperature) Boiler losses (convection and radiation)
Power input Air
Gas
TECHNICAL CHARACTERISTICS. ADI CD
Description Power output* Power input
70
85
105
120
175
200
250
325
375
450
550
650
750
354
440
530
598
675
Max. power
kW
68
85
104
120
161.8 197.5
241
294
Min. power
kW
22
27.5
33.7
38.9
51.8
77.4
94.4
Max. power
kW
69.99
87.7
107.2 123.5 166.08 202.2 246.5 300.5 361.2 448.2 548.1
m3/h
6.5
8.2
10
11.5
15.4
18.8
22.9
27.9
33.6
41.7
∆T = 10ºC
m3/h
5.8
7.3
8.9
10.3
13.9
17
20.7
25.3
30.4
∆T = 15ºC
Natural gas flow (G20) at max. power (1) Water flow
Units
63.1
113.6 140.9 229.8 258.7 291.1 619
695.8
51
57.5
64.7
37.8
45.6
51.4
58.1
m /h
3.9
4.9
6
6.9
9.3
11.3
13.8
16.9
20.3
25.2
30.4
34.3
38.7
Boiler weight without water
kg
110
116
120
135
295
330
350
440
445
490
554
579
614
Boiler water capacity
litres
30
33
36
36
77
86
90
112
118
118
210
210
223
3
* Power outputs for average water temperature of 70ºC.
ADI RANGE
Maximum operating water pressure: 5 bar Power supply: 230 V, 50 Hz, single phase, Neutral + Earth
ADI CD
(1) Natural gas LCV= 10.76 kW/m3 No limit of minimum return temperature
11
ADI RANGE Artículos Doméstico - Industriales Calefacción, S.L. www.adisa.es
calefaccion@adisa.es BARCELONA HEAD QUARTERS Tuset 8, 4º4ª 08006 Barcelona t. (+34) 93 415 00 18 f. (+34) 93 238 60 36
Factory: Arenys de Mar (Barcelona) MADRID OFFICE Cincel 11, P.I. Santa Ana 28529 Rivas-Vaciamadrid (Madrid) t. (+34) 91 366 00 24 f. (+34) 91 366 69 80
FRANCE OFFICE Immeuble Le Croissy A 52, rue d’Emerainville 77183 Croissy Beaubourg (Paris) t. (+33) 01 64 68 59 11 f. (+33) 01 64 68 60 93 www.adisa.fr chauffage@adisa.fr