Production Program
Premier supplier of water equipment
Pentair is a diversified operating company headquartered in Minnesota. Its Water Group is a global leader in providing innovative products and systems used worldwide in the movement, treatment, storage and enjoyment of water. Pentair’s Enclosure group is leader in the global market of enclosures for sensitive electronics and electrical components. Pentair is a values-driven company that brings superior products to customers through some of the world’s leading brands. Efforts in continuous improvement, strong new product development, high performance, competence, business ethics and market leadership have contributed greatly to our success. Pentair’s employees share many personal values such as accountability, deep respect for people and the environment, and a candid and practical work style. Strong customer relationships and quality products allow Pentair Water to attain the vision of being the leading provider of water equipment.
Safe, clean water for people to drink and enjoy, and for industries to use Pentair Water is playing a key role in making safe, clean water available to an ever-growing portion of the world’s population: a valuable organization is engaged to successfully serve our customers trough superior, decentralized and accountable operations and dedicated sales and marketing networks.
Pentair Water operates through an organization that includes 4 Business Units:
Pump Systems
Water Treatment
Products range from single and multistage centrifugals to shallow and deep well submersibles for residential, commercial and agriculture applications; sump, effluent and sewage pumps designed for water and wastewater applications; pressure boosting and fire fighting systems as well as circulating pumps for heating, ventilation and air conditioning.
Residential, commercial, industrial, water conditioning control valves, fiberglass wound pressure tanks and vessels, brine cabinets and storage tanks.
Pool and spa Filtration & purification Technologies Residential, commercial, and industrial filtration housings; replaceable cartridge elements; carbon block filtration; drinking water filtration system components; pumps for recreational vehicles, marine, industrial applications and food service.
A complete line of commercial and residential pool/spa equipment and accessories including pumps, filters, heaters, lights, automation, automatic pool cleaners, commercial deck equipment, barbeque deck equipment, aquatic pond products and accessories, pool tile and interior finishing surfaces, maintenance equipment, spa/jetted tub hydrotherapy fittings and pool/spa accessories.
Water Energy
Reliable pumps providing water energy. Established in 1977, Nocchi is today a part of Pentair Water group. For more than 25 years we have been designing and manufacturing water pumps providing our customers quality products and concrete solutions. Nocchi line is dedicated to engineering firms and plumbing and heating/cooling distributing centres. Within the full Nocchi range a professional customer can find products and innovative solutions to suit any need with regards to water supply and pressurization in the realm of residential and commercial building, irrigation and industry applications.
Heating, ventilation and air-conditioning Circulator pumps for circulation of hot water in central heating systems and circulation in domestic hot water service systems. Pumps for circulation of cold water and other liquids in cooling and air-conditioning systems.
Pressure boosting and fire fighting Vertical and horizontal centrifugal pumps. Multiple pump units for transfer and boosting of water. Fire-fighting systems.
Sewage and wastewater Drainage, effluent and sewage pumps, for a wide range of applications in building services.
Domestic water supply Submersible pumps, jet pumps, multistage centrifugal pumps and compact systems for water and rain water supply in home and garden applications.
Groundwater supply Submersible pumps for groundwater supply, irrigation and groundwater lowering.
3
Circulating Pumps
SR3
R2S-R2SD
R2X-R2B
CIRCULATING PUMPS FOR HEATING DOMESTIC SYSTEMS
CIRCULATING PUMPS AND TWIN CIRCULATING PUMPS FOR HEATING DOMESTIC SYSTEMS
BRONZE-STAINLESS STEEL CIRCULATING PUMPS FOR DOMESTIC WATER
H (m) 10
H (m)
H (m)
10 8
10 8
5 4
5
3
3
1
1
6 4
1 0,8 0,4
0,1
0,2 0,3
0,6
1
3
6
Q (m3/h)
Technical data
0,2 0,6
1
5 6
3
8 10
Q (m3/h)
Technical data
0,6
1
3
Flow : Q max. 10 m /h Head : H max. 8,5 m
Flow : Q max. 10 m3/h Head : H max. 9 m
Applications
Applications - Civil and industrial pressurized or open tank heating systems.
Applications
- Civil and industrial pressurized or open tank heating systems.
Usage limitations
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Liquid temperature: from +10° C to +110° C from -10° C to +110° C (SR3 25/70 mod.) - Maximum operating pressure: 10 bar - The pump must be installed with the driving shaft in horizontal position - threaded port
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Liquid temperature: from +10° C to +110° C - Maximum operating pressure: 10 bar - The pump must be installed with the driving shaft in horizontal position - Series 32 threaded ports Series 42 flanged ports
4
8 10
Q (m3/h)
Technical data
Flow : Q max. 5.5 m /h Head : H max. 7 m 3
5
3
- Sanitary hot water circulation systems, heating and conditioning systems.
Usage limitations - Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Lime-stone free water (if water exceeds 35° F a softener device must be installed) - Suggested water temperature max 60° C - Maximum operating pressure: 10 bar - The pump must be installed with the driving shaft in horizontal position
Circulating Pumps
R2C-R4C
R2CD-R4CD
R2T-R4T
MULTI SPEED SINGLE-HEAD CIRCULATING PUMPS
MULTI SPEED TWIN-HEAD CIRCULATING PUMPS
SINGLE-HEAD CIRCULATING PUMPS WITH MECHANICAL SEAL
H (m)
H (m)
H (m)
20
20
20
16
16
16
12 10 8
12 10 8
12 10 8
6 5
6 5
6 5
4
4
4
3
3
3
2
2
2
1
1 2
3 4 5
7
10
20
30 40
60 80 Q (m3/h)
Technical data
1 2
3 4 5
7
10
20
30 40
60 80 Q (m3/h)
Technical data
Flow : Q max. 90 m /h Head : H max. 18 m 3
2
3
4 5 6 7 8 10
20
30 40 60
100 Q (m3/h)
Technical data
Flow : Q max. 90 m /h Head : H max. 18 m With only one head in operation 3
Flow : Q max. 85 m3/h Head : H max. 18 m
Applications Applications
Applications
- Pressurized or open tank heating systems - Air-conditioning systems - Domestic hot water distribution systems.
- Pressurized or open tank heating systems - Air-conditioning systems - Domestic hot water distribution systems.
Usage limitations
Usage limitations
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Hot water or coolants not containing mineral oils - Liquid temperature: from -20° C to +130° C - Maximum operating pressure: 10 bar - The pump must be installed with the driving shaft in a horizontal position - Flanged ports: DN 40-50-65 PN 6/10 DN 80-100 PN 6 DN 80-100 PN 10
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Hot water or coolants not containing mineral oils - Liquid temperature: from -20° C to +130° C - Maximum operating pressure: 10 bar - The pump must be installed with the driving shaft in a horizontal position - Flanged ports: DN 40-50-65 PN 6/10 DN 80-100 PN 6 DN 80-100 PN 10
-
Heating and air-conditioning systems Water supply systems Booster systems Agriculture and fruit and vegetable crops.
Usage limitations - Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Hot water or coolants not containing mineral oils - Liquid temperature: from -20° C to +130° C - Maximum operating pressure: 10 bar - Maximum environmental temperature: 40° C - The pump may be installed with the driving shaft in all positions between horizontal and vertical - Flanged ports: DN 40-50-65 PN 6/10 DN 80-100 PN 6 DN 80-100 PN 10 5
Circulating Pumps
R2TD-R4TD
A2L - A4L
A2LD-A4LD
TWIN HEAD CIRCULATING PUMPS WITH MECHANICAL SEAL
SINGLE-HEAD CIRCULATING "IN LINE" ELECTRIC PUMPS WITH MECHANICAL SEAL
“IN LINE” TWIN HEAD CIRCULATING PUMPS WITH MECHANICAL SEAL
H (m)
H (m)
H (m)
20
60
60
16
50
50
12 10 8
40
40
30
30
25
25
20
20
15
15
10
10
8 6
8 6
5
5
6 5 4 3 2
1
4
4
2
3
4 5 6 7 8 10
20
30 40 60
100 Q (m3/h)
Technical data
1,2
3
6
12
24
60
Technical data
Flow : Q max. 85 m /h Head : H max. 18 m With only one head in operation 3
3
120 180 240 Q (m3/h)
6
12
24
60
120 180 Q (m3/h)
Technical data
Flow : Q max. 300 m /h Head : H max. 68 m
Flow : Q max. 225 m3/h Head : H max. 40 m With only one head in operation
Applications
Applications
- Heating and air-conditioning systems - Water lifting from lakes, rivers, well etc. - Irrigation systems on ground surface or by sprinkling. - Water supply and distribution for isolated houses or small villages. - Pressure systems. - Industrial services. - Domestic hot water supply systems.
- Heating and air-conditioning systems - Water lifting from lakes , rivers, wells, etc. - Irrigation systems on ground surface or by sprinkling. - Water supply and distribution for isolated houses or small villages. - Pressure systems. - Industrial services. - Domestic hot water supply systems.
Usage limitations
Usage limitations
-
-
3
Applications -
Heating and air-conditioning systems Water supply systems Booster systems Agriculture and fruit and vegetable crops
Usage limitations - Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Hot water or coolants not containing mineral oils - Liquid temperature: from -20° C to +130° C - Maximum operating pressure: 10 bar - Maximum environmental temperature: 40° C - The pump may be installed with the driving shaft in all positions between horizontal and vertical - Flanged ports: DN 40-50-65 PN 6/10 DN 80-100 PN 6 or PN 10 6
Max working pressure: 10 bar . Max liquid temperature: +130° C Min. liquid temperature : -10° C Max environmental temperature : +40°C Max liquid viscosity : 5° E
Max working pressure: 10 bar . Max liquid temperature: +130° C Min. liquid temperature : -10° C Max environmental temperature : +40°C Max liquid viscosity : 5° E
Surface Pumps
VLR
VLRX-VLRI
MULTINOX VE
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS IN AISI 316 STAINLESS STEEL
MULTISTAGE CENTRIFUGAL PUMPS
H (m)
H (m)
H (m) 120
300
300
100
200
200
90 80
100
100
70
80
80
60
60
60
40
40
40
30
30
30
20
50
0
20 1
2
3 4
6
10
20
40 60
100 Q (m3/h)
Technical data
1
2
3 4
6
10
20
40 60
100 Q (m3/h)
Technical data
L / 1' 40 Q m3/ h 2,4
60
80
100
120
140
160
180
3,6
4,8
6,0
7,2
8,4
9,6
10,8
Technical data
Flow : Q max. 72 m /h Head : H max. 260 m
Flow : Q max. 21 m3/h Head : H max. 260 m
Applications
Applications
Applications
-
-
- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis - Booster systems - Washing systems, garden irrigation fountains - Firefighting systems
3
Water supply Pressure Booster Systems Irrigation High pressure washes Firefighting systems Boiler supply Liquid transfer
Water supply Pressure Booster Systems Irrigation High pressure washes Firefighting systems Boiler supply Liquid transfer
Versions available
Versions available
“F” "in line" round flange “A” "in line" oval flange
“F” "in line" round flange “A” "in line" oval flange “V” with couplings for victaulic joints
Usage limitations
Usage limitations
- Max liquid temperature: +120° C - Min. liquid temperature : -20° C - Max working pressure: 25 bar
- Max liquid temperature: +120° C - Min. liquid temperature : -15° C - Max working pressure: 25 bar
Flow : Q max. 9,6 m3/h Head : H max. 110 m
Usage limitations - Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Maximum liquid temperature 50° C - Maximum recommended suction height 6 m with foot valve - Maximum operating pressure: 9 bar 12 bar (MULTINOX VE 200/110) 7
Surface Pumps
DHR
DHI
MCX
MULTISTAGE CENTRIFUGAL PUMPS WITH STAINLESS STEEL IMPELLERS AND DIFFUSORS
STAINLESS STEEL AISI 316 MULTISTAGE CENTRIFUGAL PUMPS
MULTISTAGE CENTRIFUGAL PUMPS
60
50
80
70
60
60
50
50
40
40
30
30
20
20
10
10
40
30
20
10
L / 1' m3/ h
Hm
Hm
Hm
Q
50
100
150
200
250
300
3
6
9
12
15
18
Technical data
Q
L / 1' m3/ h
20
40
60
80
100
120
1,2
2,4
3,6
4,8
6,0
7,2
Technical data
Q
L / 1' m3/ h
20
40
80
120
160
200
1,2
2,4
4,8
7,2
96
12
Technical data
Flow : Q max. 15 m /h Head : H max. 60 m
Flow : Q max. 7 m /h Head : H max. 63 m
Flow : Q max. 10 m3/h Head : H max. 65 m
Applications
Applications
Applications
- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis - Booster systems - Washing systems, garden irrigation, fountains - Air-conditioning systems
- Aggressive liquids transfer - Pumping and distribution of water in domestic systems used on a continuous or intermittent basis - Booster systems - Washing systems, garden irrigation, fountains
- Pumping and distribution of water in domestic systems - Booster systems - Firefighting systems - Washing systems, irrigation
Usage limitations
Usage limitations
Usage limitations
Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Maximum liquid temperature 90째 C - Maximum operating pressure: 10 bar
- Types of pumped liquid: clear, nonexplosive with no suspended solids or abrasive material - Maximum liquid temperature 90째 C - Maximum operating pressure 6 bar
- Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Maximum liquid temperature 50째 C - Maximum operating pressure 7 bar
3
8
3
Surface Pumps
MULTINOX-A
MULTINOX
MAX
JET
MULTISTAGE CENTRIFUGAL PUMP MULTINOX-A self-priming
MULTISTAGE SELF-PRIMING PUMPS
CAST IRON SELF-PRIMING PUMPS
80
70
70
60
80 70 60
60
50 50
50 40
40
40 30
30
30 20
20
20
10
10
10
Hm Q
Hm
Hm L / 1' m 3/ h
40 2,4
80 4,8
120 7,2
160 9,6
200 12
Technical data
Q
L / 1' m3/ h
20
40
60
80
100
120
1,2
2,4
3,6
4,8
6,0
7,2
Q
L / 1' m3/ h
20
40
60
80
100
120
140
160
1,2
2,4
3,6
4,8
6
7,2
8,4
9,6
Technical data
Technical data
Flow : Q max. 10 m /h Head : H max. 80 m
Flow : Q max. 6 m /h Head : H max. 55 m
Flow : Q max. 8 m3/h Head : H max. 80 m
Applications
Applications
Applications
- Pumping and distribution of water in domestic systems - Booster systems - Firefighting systems - Washing systems - Irrigation
- Pumping and distribution of water in domestic systems - Booster systems - Firefighting systems - Washing systems, irrigation
- Pumping and distribution of water in domestic systems - Booster systems - Washing systems, irrigation
3
3
Usage limitations - Type of liquid: clean water with no suspended solids or abrasive material - Maximum liquid temperature 50째 C - Maximum operating pressure 7 bar
Usage limitations
Usage limitations
Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Maximum liquid temperature 50째 C - Maximum operating pressure 9 bar
Non-aggressive and non-explosive clean liquids free of suspended solid particles and fibres - Maximum liquid temperature 50째 C - Maximum operating pressure 10 bar
Options - automatic start and stop device - version supplied with cables
9
Surface Pumps
JETINOX
NRM
NRB
SELF-PRIMING STAINLESS STEEL PUMPS
CLOSE-COUPLED CENTRIFUGAL PUMPS (2 - 4 Poles)
CENTRIFUGAL PUMPS WITH RIGID COUPLING
70
120 100
60
80 60
50
50
40 30
20 10
H (m) 125 100 80 60
40
40
30
30
20
20
10 8 6
10 8
5 Hm
Q
L / 1' m3/ h
20
40
60
80
100
120
1,2
2,4
3,6
4,8
6,0
7,2
Technical data
Hm (L/min) 100 Q 6 m3/h
200
400
12
24
6 5
1000 2000 4000 10000 60
120
240
6
10
20
600
Technical data
50 Q (m3/h)
100
200
400
Technical data
Flow : Q max. 5 m /h Head : H max. 50 m
Flow : Q max. 600 m /h Head : H max. 95 m
Flow : Q max. 330 m3/h Head : H max. 95 m
Applications
Applications
Applications
- Pumping and distribution of water in domestic systems used on a continuous or intermittent basis - Booster systems - Washing systems, garden irrigation, fountains
- Air conditioning and heating systems - Pumping of water from lakes, watercourses, wells - Overhead or surface irrigation - Industrial application. - Boosting and firefighting systems.
-
Usage limitations
Usage limitations
- Type of liquid: non-aggressive, non-explosive, free from solid particles and fibres. - Hot water for heating - Coolants - Environmental temp.: max 40° C - Temperature of pumped liquid: - 10° C + 130° C - Maximum operating pressure: 10 bar
- Type of liquid: non-aggressive, non-explosive, free from solid particles and fibres. - Hot water for heating - Coolants - Environmental temp.: max 40° C - Temperature of pumped liquid: - -10° C + 130° C - Maximum operating pressure: 10 bar
3
3
Aqueducts Irrigation Water distribution Industrial applications
Usage limitations - Type of liquid: clean water with no suspended solids or abrasive material - Maximum liquid temperature 50° C - Maximum operating pressure 6 bar
Options - automatic start and stop device - version supplied with cable and plug 10
Surface Pumps
CM
CB
EP
HORIZONTAL SINGLE STAGE AND TWO STAGES CENTRIFUGAL PUMPS
SINGLE STAGE AND TWO STAGES CENTRIFUGAL PUMPS
PERIPHERAL PUMPS
70
80
70
60
60
60
50
50
50
40
40
40
30
30
30
20
20
20
10
10
10
Hm
Q
L / 1' m3/ h
Hm
Hm 30
60
90
120
150
180
1,8
3,6
5,4
7,2
9,0
10,8
Technical data
Q
L / 1' m3/ h
40
80
120
160
200
240
2,4
4,8
7,2
9,6
11,6
14,4
Technical data
Q
L / 1' m3/ h
10
20
30
40
50
60
0,6
1,2
1,8
2,4
3,0
3,6
Technical data
Flow : Q max. 8 m /h Head : H max. 51 m
Flow : Q max. 12 m /h Head : H max. 76 m
Flow : Q max. 3,6 m3/h Head : H max. 60 m
Applications
Applications
Applications
- Pumping from wells for irrigation - Booster systems - Washing systems, garden irrigation, fountains
-
-
3
Usage limitations - Type of liquid: non-abrasive clear or slightly cloudy water - Maximum liquid temperature 90° C (model CM 90/22 50° C) - Maximum operating pressure:8 bar
3
Booster systems Small-scale irrigation Non aggressive liquids transfer Washing systems
Small-scale booster systems Domestic autoclaves Small-scale irrigation Washing systems
Usage limitations - Type of liquid:non-abrasive clear or slightly cloudy water - Maximum liquid temperature: 40° C for models 0,55 - 0,75 Kw 90° C for models 1,1 - 4,0 Kw - Maximum operating pressure: 10 bar
Usage limitations - Type of liquid: clean water with no suspended solids or abrasive material - Maximum liquid temperature 70° C - Maximum operating pressure 6.5 bar 11
Pumps for open and drilled wells
DOMINATOR 4 DOMINATOR 5 PRATIKA 4” SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMP FOR CLEAN WATER
5” SUBMERSIBLE MULTISTAGE CENTRIFUGAL PUMP FOR CLEAN WATER
70
70
60
60
50
50
40
40
30
30
20
20
10
10
STAINLESS STEEL MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS FOR CLEAR WATER 50
40
30
20
10
Hm
Hm
Q
L / 1' m3/ h
20
40
60
80
100
1,2
2,4
3,6
4,8
6
Technical data
Q
L / 1' m3/ h
Hm 20
40
60
80
100
120
140
160
1,2
2,4
3,6
4,8
6
7,2
8,4
9,6
Technical data
Q
L / 1' m3/ h
20
40
60
80
100
120
1,2
2,4
3,6
4,8
6
7,2
Technical data
Flow : Q max. 5 m /h Head : H max. 57 m
Flow : Q max. 8 m /h Head : H max. 75 m
Flow : Q max. 6 m3/h Head : H max. 46 m
Applications
Applications
Applications
- Pumping of water from traditional wells - Domestic tank installations for boosting domestic drinking water systems. - Small-scale automatic systems for garden irrigation - Surface irrigation
- Pumping of water from traditional wells - Domestic tank installations for boosting domestic drinking water systems - Small-scale automatic systems for garden irrigation - Surface irrigation
- Pumping of water from traditional wells - Domestic tank installations for boosting domestic drinking water systems - Small-scale automatic systems for garden irrigation - Surface irrigation
Usage limitations
Usage limitations
Usage limitations
- Type of liquid: clean water with no Suspended solids or abrasive material - Maximum liquid temperature 40° C - Maximum submersion under the water level 20 m
- Type of liquid: clean water with no suspended solids or abrasive material - Maximum liquid temperature 40° C - Maximum submersion under the water level 20 m
- Type of liquid: clean water with no suspended solids or abrasive material - Maximum liquid temperature 40° C - Maximum submersion under the water level 10 m
3
12
3
Pumps for open and drilled wells
SCM 4 PLUS
SCM 4 HF
SA
4" MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS
4" MULTISTAGE CENTRIFUGAL SUBMERSIBLE PUMPS
6" MULTISTAGE SUBMERSIBLE PUMPS
350
120
300
350 300
100
250
250
80 200
200
60 150
150
40
100
100
20
50
Hm
Hm
Q
L / 1' m3/ h
50
50
100
150
200
250
300
3
6
9
12
15
18
Technical data
Q
L / 1' m3/ h
50
100
150
200
250
300
350
400
3
6
9
12
15
18
21
24
Technical data
Hm
Q
L / 1' m3/ h
150
300
450
600
750 900
9
18
27
36
45
1050 1100
54
63
Technical data
Flow : Q max. 15 m /h Head : H max. 300 m
Flow : Q max. 21 m /h Head : H max. 100 m
Flow : Q max. 66 m3/h Head : H max. 270 m
Applications
Applications
Applications
- Pumping of water from drilled wells - Automatic systems for garden irrigation - Surface irrigation for agricultural use - Drinking water systems - Pumping and supply of stored deposits or of booster autoclaves for civil and industrial systems
-
-
Usage limitations
Usage limitations
Usage limitations
- Type of liquid: clean non-aggressive, non-explosive, free of solids - Maximum liquid temperature 30° C
- Type of liquid: clean non-aggressive, non-explosive, free of solids - Maximum liquid temperature 30° C
- Type of liquid: clean non-aggressive, non-explosive, free of solids - Maximum liquid temperature 30° C
Options
Options
Options
- 4” submersible motors (NEMA spec with electric cable) - 4” pump-end
- 4” submersible motors (NEMA spec with electric cable) - 4” pump-end
- 6” submersible motors (NEMA spec with electric cable) - 6” pump-end
3
66
3
Pumping of water from drilled wells Automatic systems for garden irrigation Surface irrigation for agricultural use Drinking water systems Pumping and supply of stored deposits or of booster autoclaves for civil and industrial systems
Civil and industrial supply systems Overhead or surface irrigation Boosting Firefighting Various civil and industrial applications Mains water supply systems
13
Sump sewage and effluent pumps
DP
SIMO
DPC
SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER
SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER
SUBMERSIBLE PUMP FOR DRAINING CLEAR WATER
8
8
14
6
6
12
5
5
10
4
4
8
3
3
6
2
2
4
1
1
2
Hm
Q
L / 1' m3/ h
Hm 30
60
90
120
150
180
1,8
3,6
5,4
7,2
9,0
10,8
Technical data
Q
L / 1' m3/ h
Hm 10
20
30
40
50
60
0,6
1,2
1,8
2,4
3
3,6
Technical data
Q
L / 1' m3/ h
30
60
90
120
150
180
1,8
3,6
5,4
7,2
9,0
10,8
Technical data
Flow : Q max. 9 m /h Head : H max. 7 m
Flow : Q max. 3,3 m /h Head : H max. 6 m
Flow : Q max. 10 m3/h Head : H max. 10 m
Applications
Applications
Applications
- Drainage of seepage water, pumping of rain water from a grating or drain - Draining of environments, tanks and wells
- Drainage of seepage water, pumping of rain water from grating or drain - Emptying of water deposits, collection tanks and wells
- Drainage of seepage water, pumping of rain water from grating or drain - Emptying of water deposits, collection tanks and wells
Usage limitations
Usage limitations
- Type of liquid: clear water - Maximum liquid temperature 40째 C - Maximum submersion under the water level 7 m - Minimum drainage level 10 mm - Free clearance of solids 6 mm
- Type of liquid: clear water - Maximum liquid temperature 50째 C - Maximum submersion under the water level 2 m - Minimum drainage level 3 mm - Minimum priming level 20 mm
3
3
Usage limitations
14
- Type of liquid: clear water - Maximum liquid temperature 40째 C - Maximum submersion under the water level 7 m - Minimum drainage level 3 mm (man.), 30 mm (aut.) - Free clearance of solids 5 mm
Sump sewage and effluent pumps
DRENOX
DPV
OMNIA
SUBMERSIBLE PUMPS FOR DRAINING CLEAR WATER
SUBMERSIBLE PUMP FOR DRAINING DIRTY WATER
SUBMERSIBLE SUMP PUMPS FOR DIRTY WATER
12
7
8
6
6
5
5
4
4
3
3
2
2
1
1
10
8
6
4
2
Hm
Hm
Q
L / 1' m3/ h
50
100
150
200
250
300
3
6
9
12
15
18
Technical data
Q
L / 1' m3/ h
Hm 20
40
60
80
100
120
1,2
2,4
3,6
4,8
6
7,2
Technical data
Q
L / 1' m3/ h
40
80
120
160
200
240
2,4
4,8
7,2
9,6
11,6
14,4
Technical data
Flow : Q max. 18 m /h Head : H max. 11 m
Flow : Q max. 7 m /h Head : H max. 6,5 m
Flow : Q max. 12 m3/h Head : H max. 8 m
Applications
Applications
Applications
- Drainage of seepage water, pumping of rain water, from a grating or drain, pumping of domestic waste water, drainage of environments, bathing and swimming pools, industrial applications - Fountains and water features - Surface irrigation
- Drainage of domestic dirty water - Draining of environments, tanks and wells
- Pumping of domestic waste water, draining of environments, bathing and swimming pools, industrial applications - Fountains and water features - Surface irrigation
Usage limitations
Usage limitations
- Type of liquid: dirty water with solids - Maximum liquid temperature 40째 C - Maximum submersion under the water level 7 m - Minimum drainage level 35 mm - Free clearance of solids 25 mm
- Type of liquid: waste water with solids - Maximum liquid temperature 40째 C - Maximum submersion under the water level 7 m - Minimum drainage level 35 mm - Free clearance of solids 20 mm
3
3
Usage limitations - Type of liquid: partially effluent and dirty clear water, non-aggressive liquids - Maximum liquid temperature 40째 C - Maximum submersion under the water level 7m - Minimum drainage level: from 3mm to 35 mm - Free clearance of solids: from 3 mm to 6 mm
15
Sump sewage and effluent pumps
PRIOX
MINIVORT P
MINIVORT PP
SUBMERSIBLE EFFLUENT VORTEX PUMPS FOR DIRTY WATER
SUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER
SUBMERSIBLE SEWAGE PUMPS WITH VORTEX IMPELLER
15
24
20
12
10
12
16
8 9
12
6 6
8
4 3
4
2
Hm
Hm
Q
L / 1' m3/ h
100
200
300
400
500
600
700
6
12
18
24
30
36
42
Technical data
Q
L / 1' m3/ h
Hm 100
200
300
400
500
600
700
6
12
18
24
30
36
42
Technical data
Q
L / 1' m3/ h
200
400
600
800
1000
12
24
36
48
60
Technical data
Flow : Q max. 39 m /h Head : H max. 18 m
Flow : Q max. 36 m /h Head : H max. 13 m
Flow : Q max. 50 m3/h Head : H max. 11 m
Applications
Applications
Applications
- All applications of pumping and draining effluent, civil and industrial sewage with suspended solids - Pumping stations with one or more pumps for civil and industrial plants
- Pumping and draining effluent; civil and industrial sewage with suspended solids - Draining of cesspits, cesspools, handling of effluent - Pumping stations with one or more pumps for civil and industrial plants
- Pumping and draining effluent; civil and industrial sewage with suspended solids - Draining of cesspits, cesspools, handling of effluent - Pumping stations with one or more pumps for civil and industrial plants - On request, connecting foot to make installations and maintenance easier
Usage limitations
Usage limitations
- Type of liquid: waste water and sewage - Maximum liquid temperature 40째 C - Maximum submersion under the water level 7 m - Minimum drainage level 45 mm (manual version) - Free clearance of solids 52 mm
- Type of liquid: waste water and sewage - Maximum liquid temperature 40째 C - Maximum submersion under the water level 7 m - Minimum drainage level 72 mm (manual version) - Free clearance of solids 58 mm
3
Usage limitations - Type of liquid: waste water and sewage with solids - Maximum liquid temperature 40째 C - Maximun submersion under the water level 7 m - Minimum drainage level 60 mm (manual version) - Free clearance of solids: max 50mm 16
3
Sump sewage and effluent pumps
FGT
FGV
FGC
SUBMERSIBLE PUMPS FOR WASTE WATER CUTTER PLATE IMPELLER
SUBMERSIBLE PUMPS FOR WASTE WATER VORTEX IMPELLER
SUBMERSIBLE PUMPS FOR WASTE WATER SINGLE CHANNEL IMPELLER
30
40
40
30
30
20
20
10
10
20
10
Hm
Hm
L / 1' Q m3/ h
50 3
100 6
300 18
500 30
Technical data
Q
Hm
L / 1' 50 m3/ h 3
100 6
300 18
1000 60
3000 180
10000 600
Technical data
Q
L / 1' m3/ h
1000 60
3000 180
10000 600
Technical data
Flow : Q max. 20 m /h Head : H max. 25 m
Flow : Q max. 160 m /h Head : H max. 40 m
Flow : Q max. 460 m3/h Head : H max. 34 m
Applications
Applications
Applications
- Contamined water - Sewage with fibres - Industrial waste and animal slurry chemically compatible with the pump construction materials
- Sewage with suspended solids including long fibres. - For liquid mixing in stock tanks, for industrial waste and animal slurry with solids in suspension
- Sewage, effluent and rainwaters without long fibres - Animal slurry, industrial water with solids in suspension of max diameter of 108 mm according to pumps size
3
3
Usage limitations
Usage limitations - Max temperature of pumped liquid: 40° C - Max immersion depth: 20 m - PH: between 6-11 - Running positioning: only vertical - Outlet nominal diameter: 2” gas - For continuous operation, within the allowed use limits, the submersible pump must be submerged for 2/3 of its height, at least. - Suitable for fixed installation, with rapid coupling device or more portable applications suspended or rested. - Free passage: 5 mm
Usage limitations - Max temperature of pumped liquid: 40° C - Max immersion depth: 20 m - PH: between 6-11 - Running positioning: only vertical - For continuous operation, within the allowed use limits, the submersible pump must be submerged for 2/3 of its height, at least. - Suitable for fixed installation with coupling foot, guide rails and chain, or more portable applications suspended or rested.
- Max temperature of pumped liquid: 40° C - Max immersion depth: 20 m - PH: between 6-11 - Running positioning: only vertical - Outlet nominal diameter: DN150 - For continuous operation, within the allowed use limits, the submersible pump must be submerged for 2/3 of its height, at least. - Suitable for fixed installation with coupling foot, guide rails and chain, or more portable applications suspended or rested. - Free passage: 95-108 mm. 17
Booster Systems
WATERPRESS
PRESSOMAT
SENSORMAT
BOOSTER SYSTEM WITH CAST IRON PUMP AND 24 Lt STEEL TANK
BOOSTER SYSTEMS WITH 2 HORIZONTAL OR VERTICAL PUMPS
BOOSTER SYSTEMS WITH 2 HORIZONTAL OR VERTICAL PUMPS
Technical data
Technical data
Technical data
Flow : max. 6 m /h Head : max. 60 m
Flow : max. 420 m /h Head : max. 120 m
VSD 20
FREQUENCY CHANGER UNIMAT - UNISTOP
VARIABLE SPEED PRESSURE BOOSTER SYSTEMS WITH 2 PUMPS AND 2 VSD INVERTERS
VARIABLE SPEED PRESSURE BOOSTER SYSTEMS WITH 2-3-4 VERTICAL PUMPS
UNI 9490 AND 10779 FIRE FIGHTING SYSTEMS WITH ELECTRIC AND ENGINE DRIVEN PUMPS
Technical data
Technical data
Technical data
Flow : max. 30 m3/h Head : max. 106 m
Flow : max. 288 m3/h Head : max. 120 m
Flow : max. 630 m3/h Head : max. 110 m
3
18
3
Flow : max. 630 m3/h Head : max. 120 m
VERSAILLES
PGA
SUBMERSIBLE PUMPS FOR FOUNTAINS AND WATERFALLS
SPECIAL SELF-PRIMING LIQUID RING SINGLE AND TWIN IMPELLER ENGINE PUMPS FOR DIESEL TRANSFER DRIVEN PUMPS
Technical data
Technical data
Flow : max. 18 m /h Head : max. 11 m
Flow : max. 3,6 m /h Head : max. 40 m
Flow : max. 42 m3/h Head : max. 100 m
Applications
Applications
Applications
- For fountains, water features, waterfalls in water gardens
-
-
3
BLAZE
Technical data 3
Manufacture of delivery assemblies For farm diesel transfer Farm machines Small pumping stations
ELECTRIC PANELS
VSD
Electric starter for the control and protection of single phase and three phase pumps.
VARIABLE SPEED DRIVE
Fire Fighting Tank filling Water transfer Hydrants Irrigation
EXPANSION TANKS In compliance with European Directive 97/23/EC
VSD is a device which is able to modulate the speed of a pump with the purpose to maintain constant pressure.
- steel - stainless steel - composite material
VSD1 / VSD1 basic: for three phase pumps (3x230 V) and single phase (230 V) power supply
Capacity: from 2 to 1022 L
VSD 3 : for three phase pumps (3x400 V) and three-phase (400 V) power supply 19
www.francoferrucci.com
BELGIUM
ITALY
UNITED ARAB EMIRATES
Pentair Water
Pentair Pumps
Pentair Water Middle East
Industriepark Wolfstee, Toekomstlaan 30 B-2200 HERENTALS Tel. +32.14.25.99.11 Fax. +32.14.25.99.75 www.pentairwater.com
Via Masaccio, 13 56010 Lugnano (Pisa) Tel. +39.050.71.61.11 Fax. +39.050.70.31.37 www.nocchi.it
Al Diyaffa Center, M Floor Office 104-105 P.O. Box 24670 Dubai, U.A.E. Tel. +971.43.45.50.74 Fax. +971.43.45.51.04 www.pentairwater.com
Pentair Pumps BP 92 Vedene - 84965 LE PONTET Cedex - AVIGNON Tel. 04.90.480.880 Fax 04.90.480.888 www.nocchi.it
Pentair Water 140, avenue Roland Garros 78532 BUC CEDEX Tel. +33.(0)1.39.24.15.00 Fax. +33.(0)1.39.56.03.90 www.pentairwater.com
GERMANY Pentair Water Wiesenstraße 6 Industriegebiet Nord D-64347 Griesheim Tel. +49615584170 Fax +496155841799
Via Brughiera 1 - 20010 PREGNANA MILANESE (MI) Tel. +39.02.93.27.111 Fax. +39.02.93.27.1154 www.pentairwater.com
REPUBLIC OF SOUTH AFRICA Pentair Water P.O. Box 11325, Selcourt 1567, 15 Miller Road, Nuffield, Springs - Gautenga Tel. +27.11.818.5818 Fax +27.11.818.3710
RUSSIA Pentair Pumps 4 Luchevoy Prosek Exhibition Centre “Sokolniki” Pav. 5, Off. 30 - Moscow Tel.+7-095-913 90 22, 956 55 61 Fax +7-095-234 23 50 www.nocchi.ru
UNITED KINGDOM Pentair Water Filtration Daimler Drive, Cowpen Lane Industrial Estate Billingham - Cleveland, TS23 4DJ Tel. +44 (0)1 642 370 616 Fax +44 (0)1.642.564.708 GB - 1° ED. 012006 - COD. NV260P800
FRANCE
Pentair Water