BY: JENNY BURGER
DEMOLITION PLAN ATTIC ABOVE GARAGE SECOND FLOOR
UP
THERE WILL BE NO CHANGES TO EXISTING DECK OR THE EXISTING STAIRS.
THERE WILL BE NO CHANGES TO EXISTING DECK OR THE EXISTING STAIRS.
UP
DECK 45 SQ FT
UP
DECK
45 SQ FT
5068
5068
3'-8"
4'
CLOSET
7'-4"
7'-8 3/4"
ENTRY
CLOSET 28 SQ FT
28 SQ FT
3'-8"
4'
4'
5068
7'-9 1/4" 4'
UP
DECK
45 SQ FT
S2 9'-3"
15'-4 1/4"
11'-4 1/4" 50410DC
EXISTING 12" HEADER ABOVE NICHE' OPENING
LIVING ROOM 262 SQ FT
S3
NICHE
S1
4'
16 SQ FT
3'
EP
BEDROOM
WALL LEGEND EXISTING BRICK EXTERIOR 2X6 WALL TO REMAIN EXISTING 2X4 STUD TO REMAIN WITH NEW 1/2" DRYWALL
EXISTING BRICK EXTERIOR 2X6 WALL TO REMAIN EXISTING 2X4 STUD TO REMAIN WITH NEW 1/2" DRYWALL NEW INTERIOR 2X4 WALL WITH 1/2" DRYWALL
581 SQ FT
LIVING AREA
NEW INTERIOR 2X4 WALL WITH 1/2" DRYWALL
581 SQ FT
WALLS TO BE DEMOLISHED
2468
4"
B24
B18
W3036 15 SQ FT
UTILITY CLOSET 67 SQ FT
CLNG HGHT: 8 1/2 FEET TALL
1'-5"
4'-10 3/4"
7'-4"
64" TALL WALL
3'-8 3/4"
R
SB3821
2'-10"
S4
4"
7'-9 1/4"
50410DC
23'-6" DORMERS: BOTTOM OF RIDGE: 150" BOTTOM OF 5.25" CLNG JOIST" 127" RAFTERS: 7.25" STUDS 3.5" LIVING AREA
DEMOLITION WALLS
FLOOR BELOW: EXISTING GARAGE CEILING IS 5/8" TYPE X GYPSUM BOARD. ANY AND ALL PATCH WORK WILL BE MADE WITH THE SAME 5/8" TYPE X GYPSUM BOARD.
SB24
B18
WALL LEGEND EXISTING BRICK EXTERIOR 2X6 WALL TO REMAIN EXISTING 2X4 STUD TO REMAIN WITH NEW 1/2" DRYWALL
DEMOLITION WALLS NEW INTERIOR 2X6 WALL WITH 1/2" DRYWALL & CONCRETE BOARD
NEW INTERIOR 2X6 WALL WITH 1/2" DRYWALL & CONCRETE BOARD
3'-10"
MINI- REFRIGERATOR
4'-11 1/4"
7'-8 1/2"
4'-0 3/4"
4'-1" 4'
4'-0 3/4"
WALL LEGEND
23'-6" DORMERS: BOTTOM OF RIDGE: 150" BOTTOM OF 5.25" CLNG JOIST" 127" RAFTERS: 7.25" STUDS 3.5"
7'-4 1/2"
WH
6' 4 1/2" TALL WALL
WET BAR
SHOWER
25 SQ FT
NICHE'
50410DC
LIVING AREA
UNFINISHED ATTIC STORAGE
2'-3 1/2" 50410DC
23'-6" DORMERS: BOTTOM OF RIDGE: 150" BOTTOM OF 5.25" CLNG JOIST" 127" RAFTERS: 7.25" STUDS 3.5"
8'-9 1/2"
2'-9 1/4"
2'-3 1/2"
2'-7"
ATTIC ACCESS
3'
4'
3'-11"
7'-5"
4'
4'
4'-1"
4"
29 SQ FT
9'-9 3/4"
7'-5"
3'-11"
1'-9"
19'-4 3/4"
4'-2"
7'-4 1/4"
15'-5"
23'-5 3/4"
15'-5"
50410DC
BOTTOM OF RIDGE: 180" BOTTOM OF 5.25" CLNG JOIST" 144" RAFTERS: 7.25" STUDS 3.5"
BOTTOM OF RIDGE: 180" BOTTOM OF 5.25" CLNG JOIST" 144" RAFTERS: 7.25" STUDS 3.5"
50410DC
3'-11 3/4"
7'-5"
4'
7'-5"
4'
1'-9"
EXISTING HEADER TO REMAIN.
3'-10 3/4"
23'-5 3/4"
EXISTING HEADER TO REMAIN.
2068
10'-3 1/2"
44" TALL WALL
2068
9367
44" TALL WALL
9'-3"
7'-8"
43 SQ FT
NEW INTERIOR 2X4 WALL WITH 1/2" DRYWALL
581 SQ FT
DEMOLITION WALLS
FLOOR BELOW: EXISTING GARAGE CEILING IS 5/8" TYPE X GYPSUM BOARD. ANY AND ALL PATCH WORK WILL BE MADE WITH THE SAME 5/8" TYPE X GYPSUM BOARD.
RELEASED FOR CONSTRUCTION
UP
THERE WILL BE NO CHANGES TO EXISTING DECK OR THE EXISTING STAIRS.
23'-7"
3'-8"
UP
23'-7"
NEW INTERIOR 2X6 WALL WITH 1/2" DRYWALL & CONCRETE BOARD
INSTALL 1/2" DRYWALL ON INTERIOR STUDS AND ON CEILING. FLOOR BELOW: EXISTING GARAGE CEILING IS 5/8" TYPE X GYPSUM BOARD. ANY AND ALL PATCH WORK WILL BE MADE WITH THE SAME 5/8" TYPE X GYPSUM BOARD.
GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION
EXISTING UNFINISHED ATTIC ABOVE GARAGE SECOND FLOOR
PROPOSED APARTMENT ABOVE GARAGE SECOND FLOOR MAIN FLOORING: CARPET BATH FLOORING: TILE
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:22 PM
FLOOR PLANS 1 SCALE: 1/4" 1/2" = SCALE: =1'1'- -0"0"
SHEET: 1 OF 8
CROSS SECTION 3-UPPER LEVEL ROOF, RAFTERS, RIDGES, HEADERS WINDOWS, DOORS, STUDS, INSULATION TO REMAIN. INSTALL 1/2 DRYWALL ON INTERIOR WALLS AND CEILING. ATTIC STORAGE AREAS TO REMAIN UNFINISHED.
RELEASED FOR CONSTRUCTION
EXISTING WALL
EXISTING WALL 7'-7
1/4"
9'-1"
10'-7"
EXISTING WALL
6'-4 1/2"
EXISTING WALL
EXISTING WALL
BY: JENNY BURGER
EXISTING WALL
NEW WALLS NO WORK TO BE DONE ON LOWER LEVEL CROSS SECTION 4-UPPER LEVEL
GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION
ROOF, RAFTERS, RIDGES, HEADERS WINDOWS, DOORS, STUDS, INSULATION TO REMAIN. INSTALL 1/2 DRYWALL ON INTERIOR WALLS AND CEILING. ATTIC STORAGE AREAS TO REMAIN UNFINISHED.
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
NEW WALL
5'-4"
EXISTING WALL
8'-6"
EXISTING WALL
3'
3'-8"
NEW WALL
EXISTING WALL
NEW WALL SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:22 PM
NO WORK TO BE DONE ON LOWER LEVEL
CROSS SECTION 3 AND 4 1 SCALE: 1/2" = 1' - 0"
SHEET: 2 OF 8
CROSS SECTION 1-UPPER LEVEL BY: JENNY BURGER
EXISTING WALL EXISTING WALL
EXISTING 12" HEADER TO REMAIN-
EXISTING WALL
REMOVE WALL BELOW HEADER
NO WORK TO BE DONE ON LOWER LEVEL
5'-10"
5'
EXISTING WALL
RELEASED FOR CONSTRUCTION
ROOF, RAFTERS, RIDGES, HEADERS WINDOWS, DOORS, STUDS, INSULATION TO REMAIN. INSTALL 1/2 DRYWALL ON INTERIOR WALLS AND CEILING. ATTIC STORAGE AREAS TO REMAIN UNFINISHED.
NEW WALL
EXISITING 12" HEADER IN WALL TO REMAIN
EXISTING WALL
EXISTING WALL
NEW WALL
3'
6'-6"
REMOVE WALL BELOW HEADER
NEW WALL
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
EXISTING WALL
5'-10"
EXISTING WALL
EXISTING WALL
EXISTING WALL
GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION
ROOF, RAFTERS, RIDGES, HEADERS WINDOWS, DOORS, STUDS, INSULATION TO REMAIN. INSTALL 1/2 DRYWALL ON INTERIOR WALLS AND CEILING. ATTIC STORAGE AREAS TO REMAIN UNFINISHED.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:22 PM
NO WORK TO BE DONE ON LOWER LEVEL
CROSS SECTIONS 1AND 2 1 SCALE: 1/2" = 1' - 0"
SHEET: 3 OF 8
BY: JENNY BURGER
FLOOR FRAMING PLAN
EXISTING 2X10 FLOOR JOIST (16" O.C.)
GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION
24'-9 3/4"
EXISTING DOUBLE BAND
RELEASED FOR CONSTRUCTION
EXISTING INSTALL NEW OVERSIZED 24" 2 PLY PACK BEAM
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
24'-11"
SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:56 PM
FLOOR FRAMING-ENGINEER'S LETTER 1 SCALE: 1/2" = 1' - 0"
SHEET: 4 OF 8
GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION
RELEASED FOR CONSTRUCTION
BY: JENNY BURGER
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:56 PM
PERSPECTIVE 1 SCALE: 1/2" = 1' - 0"
SHEET: 5 OF 8
GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION
RELEASED FOR CONSTRUCTION
BY: JENNY BURGER
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:56 PM
PERSPECTIVE 1 SCALE: 1/2" = 1' - 0"
SHEET: 6 OF 8
GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION
RELEASED FOR CONSTRUCTION
BY: JENNY BURGER
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:56 PM
PERSPECTIVE 1 SCALE: 1/2" = 1' - 0"
SHEET: 7 OF 8
GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION
RELEASED FOR CONSTRUCTION
BY: JENNY BURGER
THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.
SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:56 PM
PERSPECTIVE 1 SCALE: 1/2" = 1' - 0"
SHEET: 8 OF 8