GARAGE APT

Page 1

BY: JENNY BURGER

DEMOLITION PLAN ATTIC ABOVE GARAGE SECOND FLOOR

UP

THERE WILL BE NO CHANGES TO EXISTING DECK OR THE EXISTING STAIRS.

THERE WILL BE NO CHANGES TO EXISTING DECK OR THE EXISTING STAIRS.

UP

DECK 45 SQ FT

UP

DECK

45 SQ FT

5068

5068

3'-8"

4'

CLOSET

7'-4"

7'-8 3/4"

ENTRY

CLOSET 28 SQ FT

28 SQ FT

3'-8"

4'

4'

5068

7'-9 1/4" 4'

UP

DECK

45 SQ FT

S2 9'-3"

15'-4 1/4"

11'-4 1/4" 50410DC

EXISTING 12" HEADER ABOVE NICHE' OPENING

LIVING ROOM 262 SQ FT

S3

NICHE

S1

4'

16 SQ FT

3'

EP

BEDROOM

WALL LEGEND EXISTING BRICK EXTERIOR 2X6 WALL TO REMAIN EXISTING 2X4 STUD TO REMAIN WITH NEW 1/2" DRYWALL

EXISTING BRICK EXTERIOR 2X6 WALL TO REMAIN EXISTING 2X4 STUD TO REMAIN WITH NEW 1/2" DRYWALL NEW INTERIOR 2X4 WALL WITH 1/2" DRYWALL

581 SQ FT

LIVING AREA

NEW INTERIOR 2X4 WALL WITH 1/2" DRYWALL

581 SQ FT

WALLS TO BE DEMOLISHED

2468

4"

B24

B18

W3036 15 SQ FT

UTILITY CLOSET 67 SQ FT

CLNG HGHT: 8 1/2 FEET TALL

1'-5"

4'-10 3/4"

7'-4"

64" TALL WALL

3'-8 3/4"

R

SB3821

2'-10"

S4

4"

7'-9 1/4"

50410DC

23'-6" DORMERS: BOTTOM OF RIDGE: 150" BOTTOM OF 5.25" CLNG JOIST" 127" RAFTERS: 7.25" STUDS 3.5" LIVING AREA

DEMOLITION WALLS

FLOOR BELOW: EXISTING GARAGE CEILING IS 5/8" TYPE X GYPSUM BOARD. ANY AND ALL PATCH WORK WILL BE MADE WITH THE SAME 5/8" TYPE X GYPSUM BOARD.

SB24

B18

WALL LEGEND EXISTING BRICK EXTERIOR 2X6 WALL TO REMAIN EXISTING 2X4 STUD TO REMAIN WITH NEW 1/2" DRYWALL

DEMOLITION WALLS NEW INTERIOR 2X6 WALL WITH 1/2" DRYWALL & CONCRETE BOARD

NEW INTERIOR 2X6 WALL WITH 1/2" DRYWALL & CONCRETE BOARD

3'-10"

MINI- REFRIGERATOR

4'-11 1/4"

7'-8 1/2"

4'-0 3/4"

4'-1" 4'

4'-0 3/4"

WALL LEGEND

23'-6" DORMERS: BOTTOM OF RIDGE: 150" BOTTOM OF 5.25" CLNG JOIST" 127" RAFTERS: 7.25" STUDS 3.5"

7'-4 1/2"

WH

6' 4 1/2" TALL WALL

WET BAR

SHOWER

25 SQ FT

NICHE'

50410DC

LIVING AREA

UNFINISHED ATTIC STORAGE

2'-3 1/2" 50410DC

23'-6" DORMERS: BOTTOM OF RIDGE: 150" BOTTOM OF 5.25" CLNG JOIST" 127" RAFTERS: 7.25" STUDS 3.5"

8'-9 1/2"

2'-9 1/4"

2'-3 1/2"

2'-7"

ATTIC ACCESS

3'

4'

3'-11"

7'-5"

4'

4'

4'-1"

4"

29 SQ FT

9'-9 3/4"

7'-5"

3'-11"

1'-9"

19'-4 3/4"

4'-2"

7'-4 1/4"

15'-5"

23'-5 3/4"

15'-5"

50410DC

BOTTOM OF RIDGE: 180" BOTTOM OF 5.25" CLNG JOIST" 144" RAFTERS: 7.25" STUDS 3.5"

BOTTOM OF RIDGE: 180" BOTTOM OF 5.25" CLNG JOIST" 144" RAFTERS: 7.25" STUDS 3.5"

50410DC

3'-11 3/4"

7'-5"

4'

7'-5"

4'

1'-9"

EXISTING HEADER TO REMAIN.

3'-10 3/4"

23'-5 3/4"

EXISTING HEADER TO REMAIN.

2068

10'-3 1/2"

44" TALL WALL

2068

9367

44" TALL WALL

9'-3"

7'-8"

43 SQ FT

NEW INTERIOR 2X4 WALL WITH 1/2" DRYWALL

581 SQ FT

DEMOLITION WALLS

FLOOR BELOW: EXISTING GARAGE CEILING IS 5/8" TYPE X GYPSUM BOARD. ANY AND ALL PATCH WORK WILL BE MADE WITH THE SAME 5/8" TYPE X GYPSUM BOARD.

RELEASED FOR CONSTRUCTION

UP

THERE WILL BE NO CHANGES TO EXISTING DECK OR THE EXISTING STAIRS.

23'-7"

3'-8"

UP

23'-7"

NEW INTERIOR 2X6 WALL WITH 1/2" DRYWALL & CONCRETE BOARD

INSTALL 1/2" DRYWALL ON INTERIOR STUDS AND ON CEILING. FLOOR BELOW: EXISTING GARAGE CEILING IS 5/8" TYPE X GYPSUM BOARD. ANY AND ALL PATCH WORK WILL BE MADE WITH THE SAME 5/8" TYPE X GYPSUM BOARD.

GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION

EXISTING UNFINISHED ATTIC ABOVE GARAGE SECOND FLOOR

PROPOSED APARTMENT ABOVE GARAGE SECOND FLOOR MAIN FLOORING: CARPET BATH FLOORING: TILE

THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.

SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:22 PM

FLOOR PLANS 1 SCALE: 1/4" 1/2" = SCALE: =1'1'- -0"0"

SHEET: 1 OF 8


CROSS SECTION 3-UPPER LEVEL ROOF, RAFTERS, RIDGES, HEADERS WINDOWS, DOORS, STUDS, INSULATION TO REMAIN. INSTALL 1/2 DRYWALL ON INTERIOR WALLS AND CEILING. ATTIC STORAGE AREAS TO REMAIN UNFINISHED.

RELEASED FOR CONSTRUCTION

EXISTING WALL

EXISTING WALL 7'-7

1/4"

9'-1"

10'-7"

EXISTING WALL

6'-4 1/2"

EXISTING WALL

EXISTING WALL

BY: JENNY BURGER

EXISTING WALL

NEW WALLS NO WORK TO BE DONE ON LOWER LEVEL CROSS SECTION 4-UPPER LEVEL

GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION

ROOF, RAFTERS, RIDGES, HEADERS WINDOWS, DOORS, STUDS, INSULATION TO REMAIN. INSTALL 1/2 DRYWALL ON INTERIOR WALLS AND CEILING. ATTIC STORAGE AREAS TO REMAIN UNFINISHED.

THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.

NEW WALL

5'-4"

EXISTING WALL

8'-6"

EXISTING WALL

3'

3'-8"

NEW WALL

EXISTING WALL

NEW WALL SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:22 PM

NO WORK TO BE DONE ON LOWER LEVEL

CROSS SECTION 3 AND 4 1 SCALE: 1/2" = 1' - 0"

SHEET: 2 OF 8


CROSS SECTION 1-UPPER LEVEL BY: JENNY BURGER

EXISTING WALL EXISTING WALL

EXISTING 12" HEADER TO REMAIN-

EXISTING WALL

REMOVE WALL BELOW HEADER

NO WORK TO BE DONE ON LOWER LEVEL

5'-10"

5'

EXISTING WALL

RELEASED FOR CONSTRUCTION

ROOF, RAFTERS, RIDGES, HEADERS WINDOWS, DOORS, STUDS, INSULATION TO REMAIN. INSTALL 1/2 DRYWALL ON INTERIOR WALLS AND CEILING. ATTIC STORAGE AREAS TO REMAIN UNFINISHED.

NEW WALL

EXISITING 12" HEADER IN WALL TO REMAIN

EXISTING WALL

EXISTING WALL

NEW WALL

3'

6'-6"

REMOVE WALL BELOW HEADER

NEW WALL

THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.

EXISTING WALL

5'-10"

EXISTING WALL

EXISTING WALL

EXISTING WALL

GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION

ROOF, RAFTERS, RIDGES, HEADERS WINDOWS, DOORS, STUDS, INSULATION TO REMAIN. INSTALL 1/2 DRYWALL ON INTERIOR WALLS AND CEILING. ATTIC STORAGE AREAS TO REMAIN UNFINISHED.

SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:22 PM

NO WORK TO BE DONE ON LOWER LEVEL

CROSS SECTIONS 1AND 2 1 SCALE: 1/2" = 1' - 0"

SHEET: 3 OF 8


BY: JENNY BURGER

FLOOR FRAMING PLAN

EXISTING 2X10 FLOOR JOIST (16" O.C.)

GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION

24'-9 3/4"

EXISTING DOUBLE BAND

RELEASED FOR CONSTRUCTION

EXISTING INSTALL NEW OVERSIZED 24" 2 PLY PACK BEAM

THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.

24'-11"

SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:56 PM

FLOOR FRAMING-ENGINEER'S LETTER 1 SCALE: 1/2" = 1' - 0"

SHEET: 4 OF 8


GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION

RELEASED FOR CONSTRUCTION

BY: JENNY BURGER

THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.

SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:56 PM

PERSPECTIVE 1 SCALE: 1/2" = 1' - 0"

SHEET: 5 OF 8


GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION

RELEASED FOR CONSTRUCTION

BY: JENNY BURGER

THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.

SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:56 PM

PERSPECTIVE 1 SCALE: 1/2" = 1' - 0"

SHEET: 6 OF 8


GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION

RELEASED FOR CONSTRUCTION

BY: JENNY BURGER

THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.

SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:56 PM

PERSPECTIVE 1 SCALE: 1/2" = 1' - 0"

SHEET: 7 OF 8


GARAGE BONUS ROOM FINISH INTERIOR UPPER LEVEL RENOVATION

RELEASED FOR CONSTRUCTION

BY: JENNY BURGER

THE HOME OWNER AND CONTRACTOR ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL STRUCTURAL DRAWINGS MUST BE EITHER DRAWN OR APPROVED/ STAMPED BY A LICENSED ENGINEER.

SHEET SIZE ANSI D (22" x 34") DATE ISSUED: 1/31/2018 @ 5:36:56 PM

PERSPECTIVE 1 SCALE: 1/2" = 1' - 0"

SHEET: 8 OF 8


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.