Part1 Portfolio

Page 1

Architecture | Professional Work | Graphic Design

Portfolio | Callum Stubbings

August 2017

BA (Hons) Architecture


2


GENERAL INFORMATION

CALLUM STUBBINGS

LONDON CENTRAL

+61 438 676 641

LOCATION 112 CRAWFORD STREET, W1H 2JF

callum440@hotmail.com PORTFOLIO

PROFILES

http://issuu.com/callumstubbings/docs/newfolionewcastle2

https://au.linkedin.com/in/callum-stubbings-ab5b3174

https://www.instagram.com/callum440/

http://callum440.wix.com/architect

PERSONAL STATEMENT

EDUCATION

Upon graduating with second class honours from The Queensland University of Tehcnology I moved to London and began working at DaP Architects as an Architectural Assistant. Duties included 3d modelling, rendering for client presentations, Surveying and drawing up existing properties in AutoCAD. Projects included house extensions and loft conversions, in addition to office project designs.

Queensland University of Technology Bachelor of Architecture (B.Arch.) Minoring in International Business and Urban and Regional Planning 2011-2014

University of Queensland

After six months of working at DaP architects I was granted the opportunity to work with John Simpson Arhcitects in a part 1 graduate role. This has given me the opportunity to expand my skill set as an architect as I have been able to work on projects that include, The Royal College of Music, Notre Dame School of Architecture and residential projects for Eurodisney Paris. During my time at John simpson arhcitects I have contributed to Johns book released this year called “The Timeless Language of Classicism”.

Bachelors Degree, Town Planning 2010 - 2011

Brisbane Boys’ College 2001 - 2009 Senior Subjects studied English, Mathematics, Graphics, Legal Studies, Economics, Physics

.

DESIGN SKILLS

WORK EXPERIENCE John Simpson Architects Part 1 Architect - March 2016 - Present

Revit Architecture AutoCAD

DaP Architects

SketchUp

Architectural Assistant - Nov 2015 - Present

Vray for SketchUp

26 Street Design

Adobe Photoshop

Work Experience - July 2014 - Aug 2014

Adobe Illustrator

Country Road

Topaz Lab

Part-Time Sales Associate - Nov 2013 - July 2015

General Pants Co. Casual Sales Assistant - Nov 2010 - April 2013

ACHIEVEMENTS

HOBBIES & INTERESTS

Containerval University competition Third Place, 2013

Football State Squad Queensland State Squad, 2008 COFFEE

Judo National Champion National Champion, 2007

3

TRAVEL

FOOTBALL

PHOTOGRAPHY

GUITAR


Architectural Motifs motif noun 1. a decorative image or design, especially a repeated one forming a pattern 2. A repeated figure or design in architecture or decoration

4


5


ACROTERION MOTIF Traditionally mounted at the apex of a pediment of a building in a classical style, however it has been adapted for a motif that is present throughout a range of projects at John Simpson Architects. 6


FESTOON a chain or garland of flowers, leaves, or ribbons, hung in a curve as a decoration.

7


BESPOKE MOTIF ORIGINALLY DESIGNED FOR THE VENICE PALAZZO PROJECT, THIS MOTIF Draws inspiration from traditional furniture.

8


THE GRANGE FESTIVAL BOOKMARK This bookmark IS A COMBINATION OF CLASSICAL JOHN SIMPSON DESIGNED MOTIFS WHICH HAVE BEEN PREVIOUSLY BEEN USED IN the Grange, New Hall Wherwell and Venice PALAZZO PROJECTS. 9


VENICE PALAZZO

VENICE PALAZZO 10


VENICE PALAZZO

VENICE PALAZZO 11


12


“Coffer, in architecture, a square or polygonal ornamental sunken panel used in a series as decoration for a ceiling or vault. The sunken panels were sometimes also called caissons, or lacunaria.�

13


ZAC DU PRE DE CLAYE DOMAINE REGENCE DEVELOPMENT Type: LUXURY Residential CLIENT: EURO DISNEY Users: Private BUYERS Location: Paris, France

14


The design by John Simpson Architects creates a main central square with axial vistas extending into neighbouring blocks, the whole DESIGN IS based on English architectural precedents originating from the English Palladian school works of, for example, John Nash, Robert Adam and John Soane. The project has now entered tender stage. THE TEAM FOR THIS PROJECT WAS COMPRISED OF JOANNA WACKOWIAK (DIRECTOR), ETTOREE BRUNETTI (DIRECTOR OF EUROPEAN PROJECTS AND CALLUM STUBBINGS (PART 1 ARCHITECT). 15


elevations 16


17


site plan

18


east elevation

south elevation

west elevation

north elevation

19


WEST ELEVATION

20


21


22


“All classical architecture of the Greco-Roman tradition is composed, or written, in one language of forms. These elements of classical architecture include specific Moldings and assemblages of moldings called an Order. An Order is an accepted way of assembling a column (supporting element) with an entablature (spanning element) while imparting a certain character.�

23


ROYAL ARTILLERY MEMORIAL WALL GARRISON CHURCH OF ST ALBAN THE MARTYR

24


Type: Public Build CLIENT: GOVERNMENT FUNDED Users: Public Location: Larkhill, Wiltshire, UK A NEW Tercentenary Chapel and Garden of Remembrance designed by John Simpson Architects is completed at Larkhill, Wiltshire, to commemorate the Royal Artillery’s 300th anniversary. The Royal Artillery, commonly known as ‘The Gunners’, is the artillery arm of the British Army.

25


3D MODELLED RENDER

26


REALISATION

27


28


“PEDIMENT - an architectural element found particularly in classical, neoclassical and baroque architecture, and its derivatives, consisting of a gable, usually of a triangular shape, placed above the horizontal structure of the entablature, typically supported by columns.�

29


THE NEW SCHOOL OF ARCHITECTURE UNIVERSITY OF NOTRE DAME Type: Public Build Client: Notre Dame University Users: Academics Location: Notre Dame, Indiana 30


The School of Architecture at the University of Notre Dame is the world’s leading institution in the teaching of classical architecture. In 2014, John Simpson Architects won the prestigious competition to design the new buildings for the School as part of the University’s wider masterplan of the southeast quadrant, serving as the “front door” of the University. The new facilities include an auditorium, classrooms, studios, offices, labs, a new library, and various support spaces. The design takes its inspiration from the teaching methods of the Ecole des Beaux-Arts in Paris and seeks to foster interaction between faculty, staff, and students with different levels of experience. 31


first floor plan

32


basement plan

second floor plan

third floor plan 33


SECTION/ELEVATION OF THE STOA STAIRCASE

34


ELEVATION OF THE STOA STAIRCASE

35


EAST BAY ELEVATION DETAIL

36


SOUTH ELEVATION

WEST ELEVATION

SECTION

37


THE ROYAL COLLEGE OF MUSIC

Type: Public Build Client: THE COLLEGE OF MUSIC Users: Academics,STUDENTS AND THE PUBLIC Location: LONDON, UK 38


The redevelopment of the RCM estate is designed to integrate the College’s buildings more closely with its surroundings, making the most of its unique location opposite the Royal Albert Hall, which was specifically selected for the College by the Prince Consort himself when he designed the master plan for ‘Albertopolis’. The design builds on the heritage and traditions of the Royal College of Music, fashioning an environment which is architecturally harmonious and timeless, with a balance between indoor and outdoor spaces. The new architecture will blend seamlessly with the much loved architecture of Blomfield and Smith and make good the circulation for the first time since originally built. 39


CAFE/DINING AREA

INTERNAL COURTYARD

PERFORMANCE SPACE A 40


ATRIUM SPACE 41


2-

-

SECTION THROUGH COURTYARD AND PERFORMANCE SPACE A

32 0 1

11XA









522,12



528,02

017,02

527,91 012,91



 

051,81

536,71

1 60-2DA 2 60-2DA

008,61

F 60-2DA

057,51

A 30-2DA

02.GL aerA lacinhceT

LLIFNI KCIRB WEN

21.B edacrA

C 30-2DA

10 A ecapS e

E 30-2DA F 30-2DA 4

m5

0

2

3

1

42


A

1

2

12XA

12XA

cisuM fo egelloC layoR

egelloC lairepmI

H62/200 Natural Slate roofing H62/1330 Counterbattens H62/1310 Battens H62/300 Flexible Breather Membrane K11/340 Plywood roof sarking P10/204 Insulation to pitched roofs G20/220 Graded softwood for Joists and Rafters R10/320 Aluminium profiled gutter

J30/400 VCL Liquid Applied F10/520 Concrete dense blockwork 190mm

eniL llaW ytraP

J40/190 DPM RIW Sheetseal 226 J40/270 RIW Over tape

H62/840 Roof ventilator type 1 K11/360 Plywood for roof gutter and flat roof upstands F30/372 Metal Angle Support Strap H71/550 Lead weathering to cornice G20/300 Ungraded softwood for External non stuctural use F30/470 Cavity barrier F30/265 Stone fixings (CDP) H62/200 roofing P10/300 Natural Flexible Slate breather membrane H62/1330 F30/390 Counterbattens Dowel locating rods for stonework (CDP) H62/1310 Battens H62/300 Flexible Breather Membrane F30/390 Dowel locating rods for stonework (CDP) K11/340 Plywood roof sarking F22/382 Insulation Reconstructed stone cornice P10/204 to pitched roofs type 1 G20/220 Graded softwood for Joists and Rafters P10/152 Rigid Insulation R10/320 Aluminium profiled gutter

J30/302 RIW Liquid Asphault Compound M40/200 Porcelain floor tile M10/220 Unbonded fine concrete screed J30/400 VCL Liquid Applied P10/260 Insulation to underfloor heating P10/280 Vapour control layer P10/266 High Performance Insulation F10/520 Compressible Concrete densePolyethylene blockwork 190mm J40/600 Board J40/190 DPM RIW Sheetseal 226 J40/530 RIW sealing compound J40/250 RIW Structureseal

leveL roolF dnoceS - 60 001,32

J30/302 5RIW 1.F Liquid Asphault Compound M40/200 mooPorcelain R tnalP floor tile

H62/840 K11/360 R10/602 F30/372 H71/550 G20/300 F30/470 F30/600 F30/265 F30/265 P10/300 F10/200 F30/390

Blomfield Unbonded Building Existing Wall/Foundation M10/220 fine concrete screed

P10/152 Rigid Insulation F30/390 Dowel locating rods for stonework (CDP)

J40/530 J40/190 J40/270 J30/302

P10/260 P10/280 P10/266 J40/600 J40/190 J40/530 J40/250

RIW compound DPMsealing RIW Sheetseal 226 RIW Liquid Over tape RIW Asphault Compound

Insulation to underfloor heating Vapour control layer High Performance Insulation Compressible Polyethylene Board DPM RIW Sheetseal 226 RIW sealing compound RIW Structureseal

80.F rodirroC

leveL roolF tsriF - 50 006,91

J40/530 RIW sealing compound

P10/280 E05/200 K40/290 J30/250

P10/300 R10/602 K10/110 F10/520

Flexible breather membrane Aluminium rainwater hopper type 2 Metal Stud Partition System Concrete dense blockwork 190mm

F30/200 Aluminium Cut Brick Arch with Lintel R10/240 rainwater downpipe F30/372 Angle Support Strap Z22/116 Metal Silicone sealant Z22/117 Polyethylene foam cord K40/290 Type C4 Plain Ceiling Z22/111 Acoustic Intumescent Sealant For Window Details See AD4 Series

91.G yrevreS

Vapour control layer Reinforced concrete to Engineer's details Type C4 Plain Ceiling RIW Toughseal DPM

J40/250 RIW Structureseal

RIW Over tape at Abutment of New Slab WithJ40/270 Blomfield Building (AX16) E05/320 Void former to Engineer's details J40/290 ? J30/250 ? E05/310 M40/200

RIW Cavity drain ? RIW Toughseal DPM ? Lightweight concrete Porcelain floor tile blinding to Engineer's details

? M10/220 ? P10/260 ? P10/150 F10/510 P10/280 E05/200 E05/220 K40/290 J30/250

? Unbonded fine concrete screed ? Insulation to underfloor heating ? Rigid Insulation (walls) Concrete dense layer blockwork 100mm Vapour control Reinforced concrete to Engineer's details Reinforced concrete piles to Engineer's details Type C4 Plain Ceiling RIW Toughseal DPM

J40/250 J40/270 E05/320 E05/220 J40/290 P10/150 ? J40/290 J30/250 J30/250 ? P20/220 E05/310 J40/420 ? E05/200 ? ?J30/250

RIW Structureseal RIW Over tape Void formerconcrete to Engineer's details Reinforced piles to Engineer's details RIW Cavity drain Rigid Insulation (walls) ? RIW drainDPM RIW Cavity Toughseal RIW Toughseal DPM ? 200mm Skirting Lightweight concrete blinding to Engineer's details RIW Cavity drain collection channel ? Reinforced concrete to Engineer's details ? ?RIW Toughseal DPM

J40/270 P10/150 J40/290 F10/510 E05/220 P10/150 J40/290 J30/250 P20/220 J40/420

RIW Over tape Rigid Insulation (walls) RIW Cavity drain Concrete dense blockwork 100mm Reinforced concrete piles to Engineer's details Rigid Insulation (walls) RIW Cavity drain RIW Toughseal DPM 200mm Skirting RIW Cavity drain collection channel

D

AD2-07.D - Cafe/Bar External Wall Section at Eaves (AX12) leveL roolF dnuorG - 10 1 : 10

055,51

CONSTRUCTION DETAILS OF EXTERIOR COURTYARD WALL D 30-2DA

of Cavity Drain Slab Penetration (AX12)

D

dnuorG- rCafe/Bar ewoL - 20 External Wall Section at Eaves (AX12) AD2-07.D

F22/470 Reconstructed stone impost blocks andcill band course F22/352 Reconstructed stone decorative F30/600 Pre Formed DPM

F22/470 Reconstructed stone impost blocks and band course P10/300 Flexible breather membrane For Window details see AD4 F22/320 Reconstructed stoneSeries F30/735 Z22/116 G20/280 F30/470 Z22/117

Precast concrete lintel Silicone sealant Ungraded softwood for Internal non stuctural use Cavity barrierfoam cord Polyethylene

F22/352 Reconstructed stone decorative cill F30/600 Pre Formed DPM F30/390 Dowel locating rods (CDP) For French window details see AD4 Series

LFF tnemesaB - 30 leveL 008,8

E

P10/300 Flexible breather membrane AD2-07.E - Cafe / Bar External Wall Section at Door Head / Window Sill (AX12)

1 : 10

P10/300 Flexible breather membrane F22/320 R10/240 F30/735 Z22/116 G20/280 F22/210 Z22/117

tnemesaB buS eninazzeM 001,6

Reconstructed stone Aluminium rainwater downpipe Precast concrete lintel Silicone sealant Ungraded softwood Internal Reconstructed stonefor plinth typenon 1 stuctural use Polyethylene foam cord

F30/390 Dowel locating rods (CDP) For French window details see AD4 Series

AD2-07.E - Cafe / Bar External Wall Section at Door Head / Window Sill (AX12) CONSTRUCTION DETAILS OF EXTERIOR COURTYARD WALL 1 : 10

E

B 01-2DA tnemesaBbuS - 40 008,3

H62/1330 Counterbattens K11/340 Plywood roof sarking

P10/360 Inverted roof breather membrane M10/260 Laiddownpipe to Falls R10/240 Unbonded AluminiumScreed rainwater M40/200 Porcelain floor tile F22/210 Reconstructed stone plinth type 1 P20/200 300mm Flush Skirting J31/140 RIW Flexiseal Pro F30/500 Pre-Formed Cavity Tray

P10/204 Insulation to pitched roofs H71/622 hipcontrol and ridge P10/280 Lead Vapour layercapping

H71/810 Lead flashing to ridge ventilator H62/842 Roof Ventilator Type 2 G20/300 Ungraded softwood for External non stuctural use

F30/200 Cut Brickdetails Arch with Lintel For Window see AD4 Series

P10/300 Flexible breather membrane

H62/300 Flexible Breather Membrane G20/220 Graded softwood for Joists and Rafters

H71/1118 ridge roll P10/204 Timber Insulation to pitched roofs

F30/735 Precast concrete lintel F22/470 Reconstructed stone impost blocks and band course G20/280 Ungraded softwood for Internal non stuctural use

051,21

J40/270 RIW Over tape P10/150 Rigid Insulation (walls) H71/622 Lead hip and ridge capping J40/290 RIW Cavity drain F10/510 Concrete dense blockwork 100mm H71/1118 Timber ridge roll

G20/300 Ungraded softwood for External non stuctural use

Refer to AD5-G03.1 for details and cornices

1 : 10 leveL

Penetration in slab for cavity drain in accordance with Manufacturer's recommendations, coordinate details with Structural Engineer

H71/810 Lead flashing to ridge ventilator

F22/480 Reconstructed stone keystone

For Window AD4 Series F30/470Details CavitySee barrier

E05/200 Reinforced concrete to Engineer's details J30/250 RIW Toughseal DPM

H62/842 (AX12) Roof Ventilator Type 2 of Cavity Drain Slab Penetration

P10/300 Flexible breather membrane F22/470 Reconstructed stone impost blocks and band course K10/110 Metal Stud Partition System F10/520 Concrete dense blockwork 190mm

Z22/116 Silicone sealant Z22/117 Polyethylene foam cord

P10/150 Rigid Insulation (walls) Penetration in slab for cavity drain in100mm accordance with Manufacturer's F10/510 Concrete dense blockwork recommendations, coordinate details with Structural Engineer E05/220 Reinforced concrete piles to Engineer's details

BS na mrofreP

Reconstructed stone cornice type 1 Aluminium rainwater downpipe Metal Angle Support Strap Rigid Insulation Type C4 Plain Ceiling Acoustic Intumescent Sealant

P10/152 Insulation G20/280 Rigid Ungraded softwood for Internal non stuctural use

Blomfield Building Existing Wall/Foundation M40/200 Porcelain floor tile

P10/260 Insulation to underfloor heating

F22/382 R10/240 F30/372 P10/152 K40/290 Z22/111

F22/480 Reconstructed stone keystone F30/600 Pre Formed DPM Refer to AD5-G03.1 for details and cornices F30/265 Stone fixings (CDP) F10/200 Flemish Bond brickwork in lime mortar F30/735 Precast concrete lintel

J30/302 RIW Liquid Asphault Compound

at Abutment of New Slab With Blomfield Building (AX16)

50.G M10/220 Unbonded fine concrete screed gnitaeS/raB/efaC

Roof ventilator type 1 Plywood for rainwater roof gutterhopper and flat roof Aluminium type 2 upstands Metal Angle Support Strap Lead weathering to cornice Ungraded softwood for External non stuctural use Cavity barrier Pre Formed DPM Stone fixings (CDP) Stone fixings (CDP) Flexible breather membrane Flemish Bond brickwork in lime mortar Dowel locating rods for stonework (CDP)

1:60 Falls

43

M40/200 M10/280 P10/270 P10/260 P10/360 P10/280

Porcelain floor tile Concrete screed for underflooring heating Impact Resistant Foam 10mm Thick Insulation to underfloor heating Invertedcontrol roof breather Vapour layer membrane


A

B

C

7300

-

D

-

AX10

AX14

8120

E

14850

DIM TO RE OF AR AC

F

8750

5350

Rev

UP

UP

* A B C D E F G H

UP

MJ HMJ

MJ HMJ

RWP

Riser 2

G.07

G.17

DGF.25 DC - IN 30 DGF.17 DC - IN 60 35

1275

7850

G.18

G.19

Cafe/Bar

Servery

P21/216 Threshold Strip Type 5

DGF.05 DC - IH2 30 35

1320 Hoist

DGF.24 DC - IN 60 35

P21/234 Floor Trim Type 3

P21/216 Threshold Strip Type 5

Riser 5

DGF.18 DC - IN2 60 35

G.08

DGF.01 DC - IJ1 60

Circulation

4

DGF.02 DC - EB 60

Z11/200 Chequer Plate Floor

Store

Riser 4

R

MJ

RWP

6720

P21/240Z11/200 Chequer Plate Floor Movement Joint Trim Type 1

150

275

P21/216 Threshold Strip Type 5

7000

275

P21/250 Sealmaster Smart Seal

Riser 1

G.02

Seating

DGF.21 DC - EH 60 45

G.05

15,550

Cafe/Bar/Seating

15550

P pr co co us bu D de re fo dr dr ar

Z11/200 Chequer Plate Floor

Cafe/Bar/Seating

1:68

Riser 6

800

P21/204 Threshold Strip Type 1

MJ

2350

1250

2350

800

P21/250 Sealmaster Smart Seal

P21/204 Threshold Strip Type 1

3

RWP

MJ

-

DGF.22 DC - IL 0 0

6500

7550 G.01

5200

5,200

150

HMJ DGF.12 DC - IJ2 30

15,750

P21/250 Sealmaster Smart Seal

15,543

RWP

3

RWP

W0.03 DC - FB

AX13

W0.02 DC - FB

R A A

P21/250 Sealmaster Smart Seal

15536

P21/218 Threshold Strip Type 6

R A U L T U R F

R G

854

P21/230 Floor Trim Type 1

G.24

P21/240 Movement Joint Trim Type 1

P21/208 Threshold Strip Type 3

DGF.03 DC - IJ1 60

P21/230 Floor Trim Type 1

Riser 3

1800

4

7000

P21/214 Threshold Strip Type 4

DGF.04 DC - IH2 30 35

P21/216 Threshold Strip Type 5

Service Kitchen

Store & IT Hub

P21/230 Floor Trim Type 1

FOR WORKS TO FRONT YARD REFER TO BL10

Note floor finish this side of door to match existing

R L IN R

1:68

W0.01 DC - FB

DGF.13 DC - IL

G.21

Balcony P21/250 Sealmaster Smart Seal

G.06

W0.04 DC - FA

Cafe/Bar/Seating

M40/200 Porcelain Tiles Exterior 7,520

Y.01

Q25/400 Concrete Pavers

Yard

P21/250 Sealmaster Smart Seal

W0.09 DC - FB

1:64

1:68

7520

HMJ

MJ

1:80

FOR WORKS TO THE BLOMFIELD BUILDING REFER TO AD5-72 P21/250 Sealmaster Smart Seal

W0.05 DC - FA

P21/250 Sealmaster Smart Seal

W0.08 DC - FC

Q.01

HMJ

Courtyard DGF.07 DC - IE1 60 45

4220

13,980

-

EQ

EQ

1760

1

1550 P21/230 Floor Trim Type 1 Stair 07

RWP

RWP HMJ MJ

HMJ

[No Slope] 15,535

HMJ

HMJ

HMJ

DGF.08 DC - Bes. 60 50

RWP

14870

Circulation

13980

MJ

EX RWP

G.11

RWP

DGF.10 DC - IN2 60

DGF.11 DC - IN2 60

Stair 08

P21/240 Movement Joint Trim Type 1 15550

DGF.09 DC - Bes. 60 50

MJ

P21/232 Floor Trim Type 2

HMJ

War Memorial Relocated

Automated Gate

15550

P21/204 Threshold Strip Type 1

Circulation

No

HMJ

HMJ

TH WO CO WI AS

P21/240 Movement Joint Trim Type 1 1458

G.04

P21/204 Threshold Strip Type 1

Stair 06

AX11

Slot Channel Drain

Stair 01 (AD0-01)

G.12 Reception

P21/230 Floor Trim Type 1

Piano Lift Shaft

1:41

W0.06 DC - FA

RWP

EQ

EQ W0.07 DC - FB

15,423

2

MJ

15550

3200

2300

P21/230 Floor Trim Type 1

3200

3,200

15,423

P21/250 Sealmaster Smart Seal

1

W0.15 DC - RA

W0.14 DC - RA

2110

W0.13 DC - RA

RWP

MIN. 1100

2

P21/216 Threshold Strip Type 5

Cafe/Bar/Seating

3200

G.03

VOID OVER ATRIUM

Stone benches (AD1-15)

MJ RWP

DR

P21/240 Movement Joint Trim Type 1

FOR WORKS TO ENTRANCE HALL GROUND FLOOR REFER TO AL40.1 P21/220 Threshold Strip Type 7

A

B

C

D

E

F

DR

SC

As

DR

G.13 Inner Hall

0 -

-

AX10

AX14

2

4

2

1

GROUND FLOOR

44

3

5m


B

AX14

AX10

C

DIMENSIONS TO BE VERIFIED ON SITE. ONLY FIGURED DIMENSIONS TO BE USED AND ANY DISCREPANCIES IN DIMENSIONS ARE TO BE REPORTED TO THE ARCHITECT. NO DIMENSIONS ARE TO BE SCALED OFF PRINTED DRAWINGS. ANY AREAS INDICATED ON THIS DRAWING ARE FOR GUIDANCE ONLY.NO RESPONSIBILITY IS TAKEN FOR THEIR ACCURACY.

-

-

A

D

E

F

Revision Schedule

7,300

8,120

14,850

8,750

5,350

Rev

* A B C D E

Date

Issued by

Description

16/10/15 Stage E Costing Issue 02/11/15 Stage E 01/07/16 Value Engineering 12/08/16 Tender 16/09/16 Tender Update 19/01/17 TENDER 2

JWa

REV A REVEALS TO MEZZANINE WINDOWS SPLAYED, ACOUSTIC SCREENS TO EITHER SIDE OF STAGE ADJUSTED, STAIR TO TECHNICAL LEVEL ADJUSTED, REFER TO AD0-03, DOOR DSB-08 ADJUSTED. REV B WINDOW TAGS ADDED PLANT ROOM OMITTED, STAIR OMITTED, STAIR RELOCATED, RADIATORS INCORPORATED, TILE PATTERN OMITTED, BACK OF HOUSE CIRCULATION RE-ARRANGED, LEVELS INCORPORATED

C

P21/200 Threshold Strip for Acoustic Doors

4

4

VOID

3800

P21/200 Threshold Strip for Acoustic Doors DSB.05

DC - IN 60

3730

SB.02

SB.05

Lobby

Lobby

3800

DSB.03 DC - IK2 35

DSB.04 DC - IK1

Ramp 1:12

PDF and DWG formatted drawings are being issued for the project. The PDF drawings format reflects the contractual control document. The designs and

4

R10/800 Manhole Cover

DSB.02 DC - IG1 60 45

SB.12

Lobby SBM.01

K21/220 Hardwood Strip FlooringWith Wenge Strips

5,200

Dimmer Room

K21/220 P21/208 Threshold Strip Type 3

687 Hinged Access Hatch DSB.18 DC - IJ1 30

K21/220 DM.01 DC - IN 30

P21/206 Threshold Strip Type 2

DM.02 DC - IN 30

K21/220

1220

K21/220

P21/206 Threshold Strip Type 2

Door Tag Door Level D.XX DC - XXX XX XX

SB.14

Window Tag Window Level WX.XX DC - XXX

SBM.03

Control Booth

P21/200 Threshold Strip for Acoustic Doors

Stair 02 (AD0-05)

3730

DSB.06 DC - IN 60

3730

DSB.07 DC - IK1

SB.04

SB.03

DM.05 DC - IG3 60 35

3800

P21/214 Threshold Strip Type 4

AD5 - XX

2

4220

XX - Room Number

FFL Spot Level LEVEL

R10/800 Manhole Cover 1900

650

3800

650

Horizontal Movement Joint

Lobby

HMJ

-

Piano Lift Shaft P21/236 Floor Trim Type 4

SB.10

P21/200 Threshold Strip for Acoustic Doors

1234

P21/200 Threshold Strip for Acoustic Doors

2400

SB.09

Circulation

DSB.12 DC - IE2 30 40

J40/600 Flexcell board

AX11

Vertical Movement Joint

RWP

IT Hub

1

For Internal Elevations See AD5 Series of Drawings

DSB.19 DC - IR2 30 DSB.16 DC - IG1 30

Lobby

DSB.11 DC - IE2 30 40

SB.15

5800 WE

SB.07

Stairs

DSB.10 DC - IN

P21/206 Threshold Strip Type 2

1

DSB.14 DC - IG1 60 45

AX XX - Drawing Number

3400 SB.08

SBM.04

Circulation

Lobby

P21/200 Threshold Strip for Acoustic Doors

X - Section Number on Drawing

AX XX

J40/600 Flexcell board

MJ

1

101

3,200

-

X

P21/206 Threshold Strip Type 2

DSB.08 DC - IF 60 40

2 R10/800 Manhole Cover

AX12

DSB.09 DC - IK1 35

3800

3800

Lobby Ramp 1:12

730

DM.04 DC - IN 35 6100

P21/200 Threshold Strip for Acoustic Doors

2300

P21/206 Threshold Strip Type 2

2

DM.03 DC - IP 60

1335

1350

P21/200 Threshold Strip for Acoustic Doors

Window Number Design Code

Building Section

300

6100

Door Number Design Code Acoustic Rating Fire Rating

Circulation

Wenge Strips 1905

1905 3000

7,520

KEY

K21/220 Hinged Access Hatch

DC - IC1

AX13

DSB.17 DC - IJ1 30

K21/220

K21/220

WM.01 WM.01 DC - IC1

-

RWP

SB.01

Performance Space A

300

Projection Booth

WM.02 WM.02 DC -DC IC2 - IC2

2200

SBM.02

3

3800

Stairs

K21/220

AX13

Stair 5 (AD0-06) SB.11

K21/220

3

1680

3

Proposed Rain Water Pipe RWP

Existing Rain Water Pipe EX RWP

Existing Fabric Reinforced Concrete Refer to Eng's Dwg's

C

Notes THERE IS A RISK OF DEATH OR INJURY IN CONSTRUCTION IF THE WORKS ARE NOT PROPERLY PLANNED AND SUPERVISED. THE CONTRACTOR MUST NOT UNDERTAKE ANY ELEMENT OF WORK WITHOUT HAVING FIRST CARRIED OUT THE NECESSARY RISK ASSESSMENTS AND PREPARED DETAILED METHOD STATEMENTS. DRAWING STATUS

A

Mezzanine Sub Basement Plan

A

SUB-BASEMENT PLAN

TENDER 2

Sub Basement & Mezzanine Sub Basement Plan

B

1 : 50

RCM1405

1 : 50

B

C

D

E

ROYAL COLLEGE OF MUSIC, EAST COURTYARD DEVELOPMENT

F

DRAWING TITLE

SUB BASEMENT & MEZZANINE SUB BASEMENT PLAN

7,300 7300

-

-

AX10

AX14

8,120 8120

D D

E E

DIMENSIONS TO BE VERIFIED ON SITE. ONLY FIGURED DIMENSIONS

F F

TO BE USED AND ANY DISCREPANCIES IN DIMENSIONS ARE TO BE SCALE DATE

REPORTED TO THE ARCHITECT. NO DIMENSIONS ARE TO BE SCALED

16/10/2015 As OFF indicated A0 PRINTED@DRAWINGS. ANY AREAS INDICATED ON THIS DRAWING ARE FOR GUIDANCE ONLY.NO RESPONSIBILITY IS TAKEN FOR THEIR DRAWN BY CHECKED BY APPROVED BY ACCURACY.

14,850 14850

8,750 8750

PUr

5,350 5350

Rev

0

Door Installed as Part of South Building Project

3

5m

AR

4

1

Issued by

E

Description

N

AX14

2

JWa

REV.

AL43

Date

* 16/10/15 Stage E Costing Issue A 02/11/15 Stage ESI M P B 01/07/16 ValueN Engineering C 12/08/16 Tender D 19/08/16 Tender C H Update E 08/09/16 Tender I T EC F 16/09/16 Tender Update 29 GREAT JAMES STREET BLOOMSBURY LONDON WC1N 3ES TEL TENDER 020 7405 1285 FAX G 19/01/17 2 020 7831 1781 JWa SO

AX10

VLe

Revision Schedule

DRAWING No.

JO H

C C

S

B B

T

A A

E-Mail info@johnsimpsonarchitects.com

Lead Flashing

H.MJ

F

MJ

AD0-06.1

J40/800 High Performance Vapour Barrier

J40/820 Vapour Edge Tape

L30/342 ACCESS LADDER

REV F - NOTES ADDED

DB.26 DC - IN2 60

Stair 14 (AD0-09)

Handrails By Museum Designer

EQ

DB.07 DC - IN 60 35

P21/208 Threshold Strip Type 3

F.26

Room

DB.06 DC - IP 30 45

B.22

Door By Museum Designer

Stair 11 (AD0-08)

P21/208 Threshold Strip Type 3

DB.05 DC - IJ1 30 35

B.20

Circulation

B.19 DB.04 DC - IN2 60 35

IT HUB

P21/200 Threshold Strip for Acoustic Doors

J30/400 VCL Liquid Applied

EQ

P21/240 Movement Joint Trim Type 1

DB.01 DC - IJ1 60

8980

Lobby

1315

EQ

J30/400 VCL Liquid Applied

4

8850

1150

J40/820 Vapour Edge Tape RWP

UP

H.MJ

REV B = EXISTING STUDIO RECEPTION LAYOUT C JOHN SIMPSON ARCHITECTS LTD INCORPORATED, WC LAYOUT ADJUSTED STAIR TO ARCADE OMITTED, SOUTH BUILDING DRESSING ROOM LAYOUT UPDATED, MUSEUM WALL TYPE AMENDED, DOOR TO RISER 1 INCORPORATED, DOORS TO LOBBY CUPBOARDS INCORPORATED, CONTROL ROOM AND STAIR LAYOUT REARRANGED. REV D- BLOCKWORK TO MUSEUM ADJUSTED

MJ

Z11/200 Chequer Plate Floor

EQ

4

DB.02 DC - IN 60

DB.03 DC - IS 30 35

PDF and DWG formatted drawings are being issued for the project. The PDF drawings format reflects the contractual control document. The designs and drawings are copyright of John Simpson Architects and are not to be used for any other purpose than for the construction of the building they refer to at the Royal College of Music. The DWG format drawings are issued to assist the producing of designs to be supplied by others. The Contract takes sole responsibility for any information produced from the DWG format drawings and any misuse of the information on the drawings by them or their sub contractors. DWG format drawings are not to be scaled and only figured dimensions are to be used.

8,980 H.MJ

Note floor finish this side of door to match existing

P21/208 Threshold Strip Type 3

B.21

Control Room

Z11/200 Chequer Plate Floor

KEY

B.18

Door Tag

5200

Rack/Machine Room

Door Level D.XX DC - XXX XX XX

Fire Rating

Window Tag

DB.24 DC - IP2 60 45

Window Level

X

VOID OVER PERFORMANCE SPACE

AD5 - XX

J30/400 VCL Liquid Applied

WB.02 DC - ID

LEVEL

Horizontal Movement Joint

F30/300 Brick Mesh M20/258 Unilit Render

DB.27 DC - ED

AD2-20

HMJ

Floor access hatch with P21/200 reccess lid for timber flooring Threshold Strip for Acoustic Doors

FOR WORKS TO THE BLOMFIELD BUILDING REFER TO AD5-70

Doors and Wall By Museum Designer

DB.28 DC - ED

DB.23 DC - IP2 60 40

Stair 02 (AD0-05)

RWP

Existing Rain Water Pipe

SLOPE 1:60

B.12

Arcade

1320

P21/220 Threshold Strip Type 7

DB.12 DC - ID1 30 30

DB.16 DC - ID 60 30

8850

100

Circular Lift

MJ

MJ

P21/232 Floor Trim Type 2

R10/800 Pit Access Hatch P21/240 Movement Joint Trim Type 1 B.06 RWP Circulation MJ

AX11

F.24

C

1

P21/208 Threshold Strip Type 3

DB.18 DC - IE1

B.16

Store MJ

DB.34 DC - IJ2 60

H.MJ

DB.29 8,800 DC -P21/240 IJ2 60 Movement Joint Trim Type 1

DB.13 DC - IC2 60

MJ

DB.36 DC - IJ2 60

Reinforced Concrete Refer to Eng's Dwg's

P21/240 Movement Joint Trim Type 1 MJ 8,980

DB.20 DC - IG1 30

B.14

DB.35 DC - IG1 60

Existing Fabric

C

P21/208 Threshold Strip Type 3 DB.33 DC - IR1

Circulation DB.29 DC - IJ2 60

B.15

Lobby

P21/236 Floor Trim Type 4

B.05

RWP

DB.19 DC - IT 30 45

1760

Circulation MJ

2

F.23 DB.32 DC - IR1

MJ 8850

B.14

Circulation

P21/206 Threshold Strip Type 2

13250

P21/236 Floor Trim Type 4

EQ

3400 Piano Lift Shaft

DB.17 DC - IC2 40

EQ

J30/400 VCL Liquid Applied

FLOOR CONTINUES UNDER STAIR

1

B.13

Lobby

DB.11 DC - IE2 30 30

P21/204 Threshold Strip Type 1

DB.22 DC - IP2 60 45

4220

J40/810 Fully Bonded Vapour Barrier J40/820 Vapour Edge Tape

2300

J30/400 VCL Liquid Applied

3200

1600

J30/400 VCL Liquid Applied

EX RWP

3200

Foyer

R10/800 Manhole Cover

J40/600 Flexcell board

MJ

Proposed Rain Water Pipe

B.01

2

J40/600 Flexcell board

Vertical Movement Joint P21/200 Threshold Strip for Acoustic Doors

WB.01 DC - ID

P21/240 Movement Joint Trim Type 1

XX - Room Number

FFL Spot Level

7520

MJ

AX XX - Drawing Number

For Internal Elevations See AD5 Series of Drawings

B.17

Performance Space B Shell

P21/240 6 Movement Joint Trim Type 1

X - Section Number on Drawing

AX XX

W/M D/M

J40/810 Fully Bonded Vapour Barrier

J30/400 VCL Liquid Applied J30/400 VCL Liquid Applied

Window Number Design Code

Building Section

P21/200 Threshold Strip for Acoustic Doors

13000

J40/860 Propietary Pourable Grout

WX.XX DC - XXX

3

AD5-01 AX13

Door Number Design Code Acoustic Rating

8850

1260

J30/400 VCL Liquid Applied

H.MJ B.24

SLOPE 1:15

Stair 5 (AD0-06)

16800

Circulation

Refer to Acoustic Engineer's drawings for layout of Control Room

2970

Door By Museum Designer (min. 1100 Clear Effective Width)

3

DB.31 DC - IO 60 35

Riser 1

Museum

8800

For Marketing Suite Refer to BL12

P21/230 Floor Trim Type 1

8850

B.02

P21/240 Movement Joint Trim Type 1

R10/800 DB.40 Manhole Cover DC - IG4

P21/240 Movement Joint Trim Type 1

Notes P21/240 Movement Joint Trim Type 1

8800

RWP

MJ

C

THERE IS A RISK OF DEATH OR INJURY IN CONSTRUCTION IF THE WORKS ARE NOT PROPERLY PLANNED AND SUPERVISED. THE CONTRACTOR MUST NOT UNDERTAKE ANY ELEMENT OF WORK WITHOUT HAVING FIRST CARRIED OUT THE NECESSARY RISK ASSESSMENTS AND PREPARED DETAILED METHOD STATEMENTS.

P21/240 Movement Joint Trim Type 1

DB.47 DC - IR2

DRAWING STATUS

P21/204 Threshold Strip Type 1

A

B

TENDER 2 RCM1405

DB.15 DB.15 DC - IC2 60 - IC2 DC 60

DB.37 DC - IJ6 60

ROYAL COLLEGE OF MUSIC, EAST COURTYARD DEVELOPMENT

P21/208 Threshold Strip Type 3

C

B.07

Lobby

D

E

F

DB.46 DC - IR2

For Works to WC's & Studio Area See Drawings AL42.1

DRAWING TITLE

BASEMENT PLAN DB.42 DC - IG1 30

B.08

SCALE

Disabled WC

DATE

As indicated @ A0 DRAWN BY

DB.41 DC - IY 30

P21/208 Threshold Strip Type 3 8,800

DB.43 DC - IG1 30

B.10 B.10 Lobby

Lobby

DRAWING No.

R10/800 Manhole 8,800 Cover 0

4

AR

AX14

CH

1

3

5m

JWa REV.

G N

AX10

APPROVED BY

SI M P

N

SO

JO H

2

VLe

AL42 S

P21/220 Threshold Strip Type 7

T

DONALDSON ROOM

16/10/2015

CHECKED BY

PUr

I T EC

29 GREAT JAMES STREET BLOOMSBURY LONDON WC1N 3ES TEL 020 7405 1285 FAX 020 7831 1781 E-Mail info@johnsimpsonarchitects.com

BASEMENT PLAN

C JOHN SIMPSON ARCHITECTS LTD

A

B

-

C

-

AX16

AX10

7,300

D

-

E

DIMENSIONS TO BE VERIFIED ON SITE. ONLY FIGURED DIMENSIONS TO BE USED AND ANY DISCREPANCIES IN DIMENSIONS ARE TO BE REPORTED TO THE ARCHITECT. NO DIMENSIONS ARE TO BE SCALED OFF PRINTED DRAWINGS. ANY AREAS INDICATED ON THIS DRAWING ARE FOR GUIDANCE ONLY.NO RESPONSIBILITY IS TAKEN FOR THEIR ACCURACY.

F

AX14

8,120

14,850

8,750

Revision Schedule

5,350 Rev

UP

MJ MJ

RWP

P21/206 Threshold Strip Type 2

Riser 2 AMADEUS POD

Z11/200 Chequer Plate Floor

AMADEUS POD

AMADEUS POD

AMADEUS POD

AMADEUS POD

Infill windows

D1.03 DC - IG2 30 45

D1.12 DC - IN2 60 35

F.01

P21/230 Floor Trim Type 1



P21/240 Movement Joint Trim Type 1

Remove Windows and create opening making good edges

D1.19 DC - IJ1 60

P21/230 Floor Trim Type 1

18750

D1.01 DC - IJ1 60

RWP

MJ

Ramp 1:20.5

4

D1.15 DC - IN2 60 35

Riser 5

Z11/200 Chequer Plate Floor

Riser 4

REV G- ADJUSTMENTS TO EXTERNAL WALL OF ROOM G.03 AND COURTYARD

AMADEUS POD

REV H - NOTES ADDED Riser 1

Slope 1:20.5 D1.11 DC - IN2 30

PDF and DWG formatted drawings are being issued for the project. The PDF drawings format reflects the contractual control document. The designs and drawings are copyright of John Simpson Architects and are not to be used for any other purpose than for the construction of the building they refer to at the Royal College of Music. The DWG format drawings are issued to assist the producing of designs to be supplied by others. The Contract takes sole responsibility for any information produced from the DWG format drawings and any misuse of the information on the drawings by them or their sub contractors. DWG format drawings are not to be scaled and only figured dimensions are to be used.

19380

P21/208 Threshold Strip Type 3 AMADEUS POD

F.20

CMJ

Riser 6

AMADEUS POD

AMADEUS POD

AMADEUS POD

AMADEUS POD

AMADEUS POD

Store RWP

3 W1.11 DC - IE

MJ

-

JWa

P21/240 Movement Joint Trim Type 1 REV D: • Studio omitted H.MJ • Plant room from sub-basement relocated to first floor Note floor finish this side • New risers incorporated of door to match existing • Lift over-run moved to first floor • Louvers to plant room incorporated • Corridor ramps adjusted • F.03 Wall shifted REV F: STEP SHOWN TO SOUTH BUILDING AND WALL TO PLANT ROOM INCORPORATED, ARCHES TO ATRIUM ADJUSTED

5,200

HMJ

19380

Riser 3

P21/230 Floor Trim Type 1

Corridor

F.01

Corridor

2450

4

Ramp 1:20.5

Corridor

18940

D1.02 DC - IC1 30 30

F.08

Corridor

P21/206 Threshold Strip Type 2

F.09

P21/206 Threshold Strip Type 2

19380

D1.04 DC - IC1 60 30

RELOCATED FRONT DOORS

Issued by

Description

Stage E Costing Issue Stage E Stage E Costing Issue II Stage E Value Engineering Tender Tender Tender Update Tender Update TENDER 2

REV C: • Plan amendments as requested by Client during Stage E review. • Furniture incorporated to practice rooms and reception • Window tags added

MJ

HMJ MJ

Date

16/10/15 02/11/15 05/11/15 05/02/16 01/07/16 12/08/16 19/08/16 08/09/16 16/09/16 19/01/17

UP

UP

* A B C D E F G H I

RWP

AX13

W1.03 DC - SB

W1.01 DC - SB

W1.02 DC - SB

3

W2.12 DC - LC

RWP

KEY Door Tag

F.15

Plant Room W1.04 DC - SC

Door Level

D.XX DC - XXX XX XX

W2.11 DC - LC

19380

Door Number Design Code Acoustic Rating Fire Rating

W1.09 DC - SB

FOR WORKS TO THE BLOMFIELD BUILDING REFER TO AD5-73

Window Tag Window Level

7,520

W2.10 DC - LC

WX.XX DC - XXX

Window Number Design Code

Building Section W2.09 DC - LC

X

X - Section Number on Drawing

AX XX

VOID OVER CAFE/BAR/SEATING

AX XX - Drawing Number

For Internal Elevations See AD5 Series of Drawings

W1.05 DC - SC W2.08 DC - LC

AD5 - XX

XX - Room Number

FFL Spot Level

VOID OVER ATRIUM

LEVEL

2

2

MJ

Horizontal Movement Joint HMJ

F.16

3,200

D1.13 DC - IO 30 35 W1.07 DC - SB

Lift Motor Room F.18

F.19

Chiller Room

W1.06 DC - SC

Vertical Movement Joint J40/600 Flexcell board

MJ

-

Proposed Rain Water Pipe

AX11

Violin Store

J40/600 Flexcell board

RWP

Existing Rain Water Pipe

P21/214 Threshold Strip Type 4

1

1 RWP

MJ

HMJ HMJ

EX. RWP

RWP

D1.16 DC - IO2 35

F.17

RWP

RWP

D1.14 DC - IO 60 35

Plant Circulation

EX RWP

Existing Fabric Reinforced Concrete Refer to Eng's Dwg's

P21/240 Movement Joint Trim Type 1

MJ MJ

MJ

MJ

MJ

Notes

W1.12 DC - IF

W1.14 DC - IG

(WHERE EXISTING DUCT BECOMES INTERNAL THERE IS A MOVEMENT 'GAP' WHICH DOES NOT REQUIRE ANY MATERIAL INFILL. REFER TO AD2-14 FOR WATERPROOFING DETAILS).

EX. RWP

THERE IS A RISK OF DEATH OR INJURY IN CONSTRUCTION IF THE WORKS ARE NOT PROPERLY PLANNED AND SUPERVISED. THE CONTRACTOR MUST NOT UNDERTAKE ANY ELEMENT OF WORK WITHOUT HAVING FIRST CARRIED OUT THE NECESSARY RISK ASSESSMENTS AND PREPARED DETAILED METHOD STATEMENTS.

 

DRAWING STATUS

RCM1405

Up

Up

Up

FOR WORKS TO THE SENIOR COMMON ROOM REFER TO AD5-75

A

B

C

D

TENDER 2

ROYAL COLLEGE OF MUSIC, EAST COURTYARD DEVELOPMENT

Up

Up

W1.13 DC - IG

Up

MJ EX. RWP

E

F

DRAWING TITLE Up



VOID OVER CONCERT HALL SCALE

DATE

   DRAWN BY

45

1

3

JO H 5m

I

S

C



REV.

SI M P

T

Up

Up

AX14

N

AR

AX10

4

APPROVED BY

N

FIRST FLOOR PLAN

AX15

2



AL44 SO

0



CHECKED BY



DRAWING No.

HI T EC

29 GREAT JAMES STREET BLOOMSBURY LONDON WC1N 3ES TEL 020 7405 1285 FAX 020 7831 1781 E-Mail info@johnsimpsonarchitects.com C JOHN SIMPSON ARCHITECTS LTD