Consumer Units Including 17th Edition
Catalogue for 2008 - 2009 ...affordable quality
Consumer units
Including 17th Edition High Integrity Split Load Units The new consumer unit range from CED
Ample wire space for ease of access
Large knockouts for easy wiring entry Large Terminals
The new Consumer Unit range from CED has been designed with the specifier, installer and user in mind. Key Holes for easy mounting
2
Enclosures and devices are coordinated to provide comprehensive circuit protection solutions, ease of installation with a stylish contemporary design to integrate within any home. For further protection the range includes:-
Easy small knockouts for Trunking entry
n High Integrity Dual RCD Split Load Units n Split Load Units n Main Switch Units n Garage Units, Shower Units n RCD Units, MCB, RCD & RCBO To ensure protection on all circuits and to aid usability for all, CED has taken into consideration the need of RNIB and the on - off symbols are now embossed into each unit.
Quick 1/4 turn locking mechanism Transparent Lid
www.ced-elec.co.uk
From the inception of the design, CED have worked closely with contractors and electricians, to offer the homeowner products that not only provide safety and peace of mind, but that are easy to use and pleasing on the eye. n RCD protection (will disconnect the protected circuits whenever it detects current leaking from the circuits) n Safe and secure n MCB, RCD, RCBO to suit most combinations n Supplied with kit, contains - Pre-printed circuit designations Labels, Mounting Screws & Blanks
All CED consumer units have been specially designed to have completely removable Pan Assembly and Busbar for easy installation and rapid unit assembly.
Consumer Unit SLRRM552
Catalogue for 2008 - 2009
Split Load Unit CU14SL
Consumer Units
63A RCD GU563/632
n Manufactured in accordance with IEC 60439-3 n 230-240v-50Hz n Modern - user friendly design quick and easy to install n Compact and robust construction n Moulded self extinguishing ABS (flame retardant material) - Off white colour n Polycarbonate drop down transparent cover to protect against dust n 1/4 turn quick release screw covers - (time saving) n 4 wall mounting large size key holes for easy fixing n Easy knockouts (cut outs) on the base can be removed with sharp Stanley knife (time saving) n Generous Internal cabling space above RCBO’s (for time saving wiring) n Easily removable pan assembly (time saving for easy wiring) n Separate earth & neutral terminals at the top for easy wiring & identification n Captive terminal screws n IP20 Busbar shrouds n Easy cut - bus bar offer wider choice to the customer for selecting split load (consumer units) n 6kA MCB to IEC60898-1 including compliance to 17th Edition
3
N.B. All consumer units must be fitted with CED circuit breakers.
Shower Unit SU363/50
...simple & easy to use
17th EDITION SPLIT LOAD
Consumer units With fitted RCD & Main Switch
4
SLRRM552
30mA RCD
Spare
6A MCB
6A MCB
32A MCB
50A MCB
30mA RCD
Smoke alarms
45A MCB
Burglar Alarm
32A MCB
Shower
Cooker
32A MCB
Upstairs Sockets
Upstairs Sockets
6A MCB
Upstairs Lights
Downstairs Sockets
6A MCB
Downstairs Lights
Upstairs Lights
www.ced-elec.co.uk
Hall & Stair Lights
Typical Configuration
6A 30mA RCBO
6A 30mA RCBO
Main Isolator
Uses two RCD protected sections and a number of ways for dedicated (High Integrity Circuits) using 30mA RCBO’s.
Moulded Split Load Consumer Units 17th Edition Moulded High Integrity Dual RCD Load Units (without MCB) Code
Description
SLRRM552
2x80A RCD 1x100A Main Switch 5+5 MCB on RCD 2 MCB/RCBO on Main Switch 12 Way Board
Specification
Isolator
RCD
WxHxD Dimensions (mm)
MCB
BOARD-IEC604393 MCB-IEC60898 RCD-IEC61008
100A DP
80A DP 30mA
399x230x120
None
Specification
Isolator
RCD
WxHxD Dimensions (mm)
MCB
Moulded Dual RCD Split Load Units (without MCB) Code
Description
SLRRM66
2x80A RCD 1x100A Main Switch 6+6 MCB on RCD 12 Way Board
BOARD-IEC604393 MCB-IEC60898 RCD-IEC61008
100A DP
80A DP 30mA
399x230x120
None
SLRRM44
2x80A RCD 1x100A Main Switch 4+4 MCB on RCD 8 Way Board
BOARD-IEC604393 MCB-IEC60898 RCD-IEC61008
100A DP
80A DP 30mA
327x230x120
None
“MCB’s supplied separately and as required by customer”.
Please refer to the back page of the catalogue for 17th Edition specification.
SPLIT LOAD
Consumer units Complete with MCB
Accessory Packs Included contains: n Pre-printed circuit identification labels n Blanks n Phase insulator
Catalogue for 2008 - 2009
SLRM55CB
5
Split Load Consumer Units - 10 Way 5+5 c/w MCB - 100A Main Switch & 80Amp 2P RCD 30mA Code
Description
Specification
SLRM55CB
80A RCD 1x100A Main Switch 10-MCB 10 Way Board
Board-IEC604393 MCB-IEC60898 RCD-IEC61008
SLRM55CB/63 **
63A RCD 1x100A Main Switch 10-MCB 10 Way Board
Board-IEC604393 MCB-IEC60898 RCD-IEC61008
Isolator 100A DP
100A DP
RCD 80A DP 30mA
63A DP 30mA
WxHxD Dimensions (mm)
B Type MCB
327x230x120
3x6A MCB 2x16A MCB 4x32A MCB 1x40A MCB
327x230x120
3x6A MCB 2x16A MCB 4x32A MCB 1x40A MCB
32A MCB
30mA RCD
Cooker
Shower
32A MCB
Kitchen sockets
Downstairs Sockets
16A MCB
Upstairs sockets
Immersion Heater
6A MCB
Downstairs Lights
Upstairs Lights
6A MCB
Bathroom Lights
Outside Lights
Typical Example
6A MCB
6A MCB
32A MCB
32A MCB
40A MCB
Main Isolator
With one RCD protected section with MCB’s and RCBO’s on the switch side. ** To special order (available on request). Please refer to the back page of the catalogue for 17th Edition specification.
...affordable quality
Garage & Shower units Complete with MCB (Ready to use)
6
GU563/632
SU363/50
SU363/50
Moulded Garage Units Garage Unit - 5 Way with 63A DP RCD 30mA & MCB
www.ced-elec.co.uk
Code
Description
Specification
Rated
Construction
GU563/632
5 Module 3 Way Moulded Garage Unit c/w 63A DP RCD 30mA 1xB6-MCB & 1B32 – MCB
IEC60439-3
IP55
Moulded ABS base Transparent Polycarbonate Cover
WxHxD Dimensions (mm) 136x184x103
Moulded Shower Unit - 3 Way with 63A DP 30mA RCD & MCB Code
Description
Specification
Rated
Construction
SU363/50
3 Module 1 Way Moulded Shower Unit c/w 63A DP RCD 30mA 1xB50-MCB
IEC60439-3
IP55
Moulded ABS base Transparent Polycarbonate Cover
n RCD to BSEN61008-1 n Terminal Capacity upto 352mm n MCB 6kA IEC60898-1 Single Pole n IP55
WxHxD Dimensions (mm) 100x184x103
SPLIT LOAD
Consumer units
For greater flexibility to suit your own combination of MCB/RCBO
Without MCB
CU14SL
CU18SL
n 10 Way Consumer Unit Split Load -100A
n 14 Way Consumer Unit Split Load -100A
n 18 Way Consumer Unit Split Load -100A
2P Switch 80A - 2P RCD (without MCB) n 6 Spaces for MCB/RCBO
2P Switch 80A - 2P RCD (without MCB)
n 10 Spaces for MCB/RCBO
2P Switch 80A - 2P RCD (without MCB) n 14 Spaces for MCB/RCBO
10 Way Moulded Consumer Unit - Split Load (without MCB) c/w (A) 100A 2P Main Switch (B) 80A 2P - RCD - 30mA Code CU10SL
WxHxD Dimensions (mm)
Specification
Isolator
RCD
Board IEC-60439-3
100A DP IEC60947-3
80A DP 30mA EEC 61008
255x230x120
MCB/RCBO None MCB-IEC 60898 RCBO-IEC61009
7
14 Way Moulded Consumer Unit - Split Load (without MCB) c/w (A) 100A 2P Main Switch (B) 80A 2P - RCD - 30mA CU14SL
Board IEC-60439-3
100A DP IEC60947-3
80A DP 30mA EEC 61008
Catalogue for 2008 - 2009
CU10SL
327x230x120
None MCB-IEC 60898 RCBO-IEC61009
18 Way Moulded Consumer Unit - Split Load (without MCB) c/w (A) 100A 2P Main Switch (B) 80A 2P - RCD - 30mA CU18SL
Board IEC-60439-3
100A DP IEC60947-3
80A DP 30mA EEC 61008
399x230x120
None MCB-IEC 60898 RCBO-IEC61009
Upstairs Lights
Immersion Heater
Downstairs Sockets
Shower
Bathroom Lights
Downstairs Lights
Upstairs sockets
Kitchen sockets
Cooker
30mA RCD
Outside Lights
Typical Example
6A MCB
6A MCB
16A MCB
32A MCB
45A MCB
6A RCBO
6A RCBO
32A RCBO
32A RCBO
40A RCBO
Main Isolator
With one RCD protected section with MCB’s and RCBO’s on the switch side.
N.B. Fitted with continuous Busbar for configuration required by the customer.
...simple & easy to use
MAIN
Consumer units
For low budget and flexible choice of MCB/RCBO
With Main Switch & RCD
Burglar Alarm
Upstairs Lights
Downstairs Lights
Immersion Heater
Kitchen Sockets
Upstairs Sockets
Downstairs Sockets
Shower
Cooker
8
Smoke alarms
Typical Example
6A 30mA RCBO
6A 30mA RCBO
6A 30mA RCBO
6A 30mA RCBO
16A 30mA RCBO
32A 30mA RCBO
32A 30mA RCBO
32A 30mA RCBO
32A 30mA RCBO
40A 30mA RCBO
Main Isolator
Utilising RCBO’s throughout would provide a secure dedicated 30mA protected supply to every circuit.
Moulded Consumer Unit with 80A DP RCD 30mA as Main Switch for Garage Unit or Shower Unit Application (without MCB)
CU4R
Code
Description
Specification
Rated
Construction
CU4R
4 Modules 2 Way Moulded Consumer Unit c/w 80A - DP RCD as Switch (MCB not included)
IEC60439-3
IP20
Moulded ABS Base Transparent Polycarbonate Cover
WxHxD Dimensions (mm)
MCB
145x230x120
None
WxHxD Dimensions (mm)
Vertical Keyhole Distance
Moulded Consumer Unit with 100A - Main Switch as an (Isolator) Code
Description
Specification
Rated
Construction
IP20
Moulded ABS Base Transparent Polycarbonate Cover
145x230x120
168mm
220x230x120
168mm
www.ced-elec.co.uk
CU4S
4 Module 2 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)
IEC60439-3 CE
CU8S
8 Module 6 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)
IEC60439-3 CE
IP20
Moulded ABS Base Transparent Polycarbonate Cover
CU10S
10 Module 8 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)
IEC60439-3 CE
IP20
Moulded ABS Base Transparent Polycarbonate Cover
255x230x120
168mm
CU14S
14 Module 12 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)
IEC60439-3 CE
IP20
Moulded ABS Base Transparent Polycarbonate Cover
327x230x120
168mm
CU18S
18 Module 16 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)
IEC60439-3 CE
IP20
Moulded ABS Base Transparent Polycarbonate Cover
399x230x120
168mm
Metal Consumer Units -100A DP Main Switch - Isolator Code
Description
MCU4S
4 Ways Metal Consumer Unit c/w 100A DP isolator
MCU14S
14 Ways Metal Consumer Unit c/w 100A DP Isolator
MCU4S
Specification
WxHxD Dimensions (mm)
Rated
Construction
IEC60439-3
IP20
Metal sheet grey Epoxy painted base Transparent Polycarbonate Cover
130x190x110
IEC60439-3
IP20
Metal sheet grey Epoxy painted base Transparent Polycarbonate Cover
310x190x110
MCB, RCBO & RCD units
For consumer units
RCD40BR
RCD63BR
MCB
RCBO RCD80BR
RCD25BR
n RCBO is a combination of RCD and MCB n RCBO to IEC61009 n 30mA 6A-40Amp n Single Module n B Type Series
MCB - B Type 6kA SP N.B. All consumer units must be fitted with CED circuit breakers.
Code
Description
CUB6SP
6A-SP MCB - B Type
CUB10SP
10A-SP MCB - B Type
CUB16SP
16A-SP MCB - B Type
CUB20SP
20A-SP MCB - B Type
CUB32SP
32A-SP MCB - B Type
CUB40SP
40A-SP MCB - B Type
CUB50SP
50A-SP MCB - B Type
CUB63SP
63A-SP MCB - B Type
CUBLANK
Blank for Consumer Unit
RCBO 1 Module (single module)
RCBO20
Code
Description
RCBO6
Single Modular RCBO 6A 30mA
RCBO10
Single Modular RCBO 10A 30mA
RCBO16
Single Modular RCBO 16A 30mA
RCBO20
Single Modular RCBO 20A 30mA
RCBO25
Single Modular RCBO 25A 30mA
RCBO32
Single Modular RCBO 32A 30mA
RCBO40
Single Modular RCBO 40A 30mA
Catalogue for 2008 - 2009
n IEC 60898-1 n Breaking Capacity -6kA n B Type Series n Safety Finger Proof Terminals n Terminal Capacity Up To 35mm2 Cable n Various Rating - 6A-63A SP n Protection Against Overload / Short-Circuit n Dimension 40x18x80mm (45mm Projection)
9
RCD Sockets Code
Description
RCDMSSK2
RCD Metal Clad Twin Switched Socket
RCDSK2
RCD Twin Unswitched Socket
RCDSK2
RCDMSSK2
...affordable quality
RCD & Busbar
RCD (Residual Current Devices)
For consumer units
n BSEN61008-1 n RCD - Prevent fatal electric shock on a person by reducing to “safe” levels the value and the time a person is exposed to current flowing through the body n RCD - Protect plant & machinery from fire by a current passing from live to earth that a fuse or circuit break may not detect n RCD should be used along with MCB to detect, short circuit and overload current n 30mA Trip Double Pole n 25A -80Amp options n Available in 2 Pole
10
2 Pole RCD 25A-80A Code
Description
Poles
Sensitivity
RCD25BR
25A DP RCD 30mA
2
30mA
RCD40BR
40A DP RCD 30mA
2
30mA
RCD63BR
63A DP RCD 30mA
2
30mA
RCD80BR
80A DP RCD 30mA
2
30mA
Busbar for Split Load/Standard Consumer Units Code
Description
BB3
Busbar for 3 Way
Dimensions (mm) -
BB10
Busbar for 10 Way
206x28x2
BB14
Busbar for 14 Way
278x28x2
BB18
Busbar for 18 Way
366x28x2
MOULDED
Wall Mounted Enclosures For RCD / MCB
General Features www.ced-elec.co.uk
n IMQ, IEC670-1,94 Double Insulated n Colour - Standard (RAL7035) - White n Material - Insulating and self extinguishing (ABS) material for longer life n Temperature - (-15°C to + 60°C)
Weatherproof Moulded Enclosures
n Approval IP55 n Surface Mounting with hinged lid (clear tinge of Blue) n Suitable for interior and exterior use
Moulded Enclosures
n Approval IP44 n Surface Mounting - Open type n Suitable for indoor use
PE2
PE4
Moulded Wall Mounted (ABS) Enclosures for RCD/CB CE IMQ Approved
PE6
Modules
Rated
WxHxD Dimensions (mm)
No. Knockouts
Fixing Centre (mm)
PVC Enclosure with Lid
3
IP55
83x175x114
1 (each side)
131
PVC Enclosure with Lid
5
IP55
125x175x114
2 (each side) 2 (top & bottom)
131
-
-
Code
Description
PE3WP PE5WP
Moulded Wall Mounted (ABS) Enclosures for RCD/CB PE2
PVC Enclosure
2
IP44
51x130x 60
PE4
PVC Enclosure
4
IP44
88x130x60
-
-
140x165x72
2 (each side) 2 (top & bottom)
-
PE6
PE5WP
PVC Enclosure
6
IP44
CED Consumer Units and the 17th Edition Under the 17th edition wiring regulations (from January 2008) the following will apply to all domestic and residential installations.
Note: Additional protection is provided as additional protection. It does not obviate the need for circuit protection by circuit breakers or fuses. 1. Regulation 411.3.3 socket outlets with rated current not exceeding 20A that are for general use by ordinary persons. 2. Regulation 701.411.3.3 Additional protection shall be provided for all circuits of the location by use of one or more 30mA RCD. 3. Regulations 522.6.6 522.6.7 522.6.8 cables concealed in a wall or partition at less than 50mm depth and without earthed mechanical protection e.g. conduit. 4. Regulation 314.1 Every installation shall be divided into circuits as necessary to avoid danger and inconvenience in the event of a fault. Take account of danger that may arise from failure of a single such as a lighting circuit, reduce the possibility of unwanted tripping of RCD etc. 4. Regulation 314.2 Separate circuits to be provided for parts of the installation that need to be separately controlled in such a way that those circuits are not affected by the failure of other circuits.
Catalogue for 2008 - 2009
1. All socket outlets should be protected by 30mA RCD whether on ground floor of a house or the top floor of high rise apartment block. 2. All circuits in a room with a fixed bath or shower should be protected by one or more 30mA RCD’s. 2. All cables concealed in metal stud partitions (common in new build) should be protected by 30mA RCD’s. 3. All cables buried beneath the plaster surface of a wall or partition (at less than 50mm) should be protected by 30mA RCD’s. 4. Installations should be divided up into circuits so as to take account of danger and inconvenience caused by a single fault - e.g. such as a lighting circuit. 4. Installations should be designed and arranged so as to prevent unwanted tripping of the RCD’s.
REGULATION SUMMARY Regulation
Relating To
Examples
Additional Protection
Sockets up to 20A rating for general use by ordinary persons
Upstairs Sockets Downstairs Sockets Kitchen Sockets Cooker Outlets with Integral 13A Socket Garage Sockets Plus and other sockets up to 20A rated
30mA RCD
701.411.3.3
All circuits in a room with a fixed bath or shower
Shower Circuit Lighting Circuit Heating Circuit Ventilation Circuit Shaver Socket Plus other Circuits
30mA RCD
522.6.6 522.6.7 and 522.6.8
All circuits buried in a wall or partition at less than 50mm and without mechanical protection
Downstairs Lighting Upstairs Lighting Immersion Heater Burglar Alarms Smoke Alarms Plus other circuits
30mA RCD
411.3.3
11
British Standards and IEE regulations are subject to change and amendments. This guide is not a substitute for the regulations which should always be used for all types of electrical installation work.
Key symbols used for codes n SL = Split Load n CU = Consumer Unit n R = RCD n M = Main Switch n S = Main Switch
...simple & easy to use
Introducing our new 2008/2009 catalogue for our completely new range of Consumer Units, specifically manufactured to meet the very high standards required by electricians and structural engineers. Designed to provide the widest versatility whilst being robust and durable.
Intr odu a com cing our plet new inst ely 200 rum new 7/2 ents 008 ver , spe range y high of pro catalogu cific stan ally fess igne dar iona e with ds req manuf d to l test actu pro y to uire vide red use d by to me the feat elec high ure et tric s. est al eng the acc ura cy with ineers. ma ny
Des
Guid
e
eas
RS
cif Spe &
08
SITE EL
Ca
- 20
.uk
08
RM8 1RX (England)
11/07/2007 12:15:35
Sou rce Fo r c tr ic
- 2008
E le
r 2007
- 2008
g le
gue fo
12:15: 35
r 2007
in AS
11/07/ 2007
S
Catalo
www.ced-elec.c
2-3
ECTRIC
gue fo
Branch Stamp:
Dagenham Essex
Road, 020 8503 8900 8503 8500 - Facsimile. Telephone. 020 - email. info@ced-elec.co.uk o.uk
44-48 Freshwater
Tester Cover2.indd
Catalo
07
.co LIGHT METERS
20
lec
p:
for
RS
ch Stam
ue
TE
Bran
0
talog
ME
ced-e
HT
w.
LIG
www.ced-elec.co.uk
ww
ers Buy
Pro Test fessio Inst nal rum ents
2007 - 2008
- 20
ional Profess uments tr s Test In 2007 - 2008
07
2-3
Catalogue for
20
48
2.indd
Professional s Test Instrument
S
for
CLAMP METERS
44-
Cover
ER
ue
CL AM P ME TE RS VOLTAGE TESTERS
Teleph Freshwa w.c one. ter Roa ed020 d, Dag elec enh .co 8503 .uk am - em 8500 Ess ex ail. info - Facsim RM8 @c ile. 1RX (En edelec .co 020 850 gland) .uk 3 890
ww Tester
ET
Catalogue for
iers
IM
MULTIMETE
talog
s!
LT
Ca
l pr
ct odu
www.ced-elec.co.uk
ca ctri
IO N
MU
.uk
D IT 5E
.co
Ele
200
lec
S
Y
ced-e
gle
AR
w.
in AS
ce our
Fo r
RU
catalogue with VO new 2007/2008 LT Introducing our test AG range of professional E TE a completely new to meet the manufacturedST ER S instruments, specifically engineers. required by electrical very high standards with many the highest accuracy Designed to provide easy to use features.
ww
FEB
2 N O.
rod al P u c ts !
www.c ed-ele c.co.u
CED CTR
k
ELE IC A L EB -F RU AR Y
RX. 900 81 8 RM 503 8 ex E s s ( 0 2 0 ) .c o .u k m c a . e n h s im il e c e d - e le g a ,D Fa c fo @ o a d 5 0 0 a il . in rR 8 ate 503 k - Em 8 .u shw Fr e ( 0 2 0 ) e le c .c o 8 4 . 4 4 - h o n e w w.c e d p Te leb s it e . w
200 D IT 5E IO N
N O. 2
500 38 0 850 0 890 2 0 503 ne 8 o h ep 020 Te l ile sim Fac
We
ED C
2 | 00
| 05
Other material We have a range of literature that we have produced including:LED Lighting, Site Electric’s, Professional Test Instruments and our Main Catalogue all of which can be requested. If you require a copy then please contact us at the address below.
www.ced-elec.co.uk Branch Stamp:
44-48 Freshwater Road, Dagenham Essex RM8 1RX (England)
Telephone. 020 8503 8500 Facsimile. 020 8503 8900
www.ced-elec.co.uk - email. info@ced-elec.co.uk CED | edc1301 | 08/09