Including 17th Edition High Integrity Split Load Units The new consumer unit range from CED

Ample wire space for ease of access

Large knockouts for easy wiring entry Large Terminals

The new Consumer Unit range from CED has been designed with the specifier, installer and user in mind. Key Holes for easy mounting

2

Enclosures and devices are coordinated to provide comprehensive circuit protection solutions, ease of installation with a stylish contemporary design to integrate within any home. For further protection the range includes:-

Easy small knockouts for Trunking entry

n High Integrity Dual RCD Split Load Units n Split Load Units n Main Switch Units n Garage Units, Shower Units n RCD Units, MCB, RCD & RCBO To ensure protection on all circuits and to aid usability for all, CED has taken into consideration the need of RNIB and the on - off symbols are now embossed into each unit.

Quick 1/4 turn locking mechanism Transparent Lid

www.ced-elec.co.uk

From the inception of the design, CED have worked closely with contractors and electricians, to offer the homeowner products that not only provide safety and peace of mind, but that are easy to use and pleasing on the eye. n RCD protection (will disconnect the protected circuits whenever it detects current leaking from the circuits) n Safe and secure n MCB, RCD, RCBO to suit most combinations n Supplied with kit, contains - Pre-printed circuit designations Labels, Mounting Screws & Blanks

All CED consumer units have been specially designed to have completely removable Pan Assembly and Busbar for easy installation and rapid unit assembly.


Consumer Unit SLRRM552

Catalogue for 2008 - 2009

Split Load Unit CU14SL

Consumer Units

63A RCD GU563/632

n Manufactured in accordance with IEC 60439-3 n 230-240v-50Hz n Modern - user friendly design quick and easy to install n Compact and robust construction n Moulded self extinguishing ABS (flame retardant material) - Off white colour n Polycarbonate drop down transparent cover to protect against dust n 1/4 turn quick release screw covers - (time saving) n 4 wall mounting large size key holes for easy fixing n Easy knockouts (cut outs) on the base can be removed with sharp Stanley knife (time saving) n Generous Internal cabling space above RCBO’s (for time saving wiring) n Easily removable pan assembly (time saving for easy wiring) n Separate earth & neutral terminals at the top for easy wiring & identification n Captive terminal screws n IP20 Busbar shrouds n Easy cut - bus bar offer wider choice to the customer for selecting split load (consumer units) n 6kA MCB to IEC60898-1 including compliance to 17th Edition

3

N.B. All consumer units must be fitted with CED circuit breakers.

Shower Unit SU363/50

...simple & easy to use


17th EDITION SPLIT LOAD

Consumer units With fitted RCD & Main Switch

4

SLRRM552

30mA RCD

Spare

6A MCB

6A MCB

32A MCB

50A MCB

30mA RCD

Smoke alarms

45A MCB

Burglar Alarm

32A MCB

Shower

Cooker

32A MCB

Upstairs Sockets

Upstairs Sockets

6A MCB

Upstairs Lights

Downstairs Sockets

6A MCB

Downstairs Lights

Upstairs Lights

www.ced-elec.co.uk

Hall & Stair Lights

Typical Configuration

6A 30mA RCBO

6A 30mA RCBO

Main Isolator

Uses two RCD protected sections and a number of ways for dedicated (High Integrity Circuits) using 30mA RCBO’s.

Moulded Split Load Consumer Units 17th Edition Moulded High Integrity Dual RCD Load Units (without MCB) Code

Description

SLRRM552

2x80A RCD 1x100A Main Switch 5+5 MCB on RCD 2 MCB/RCBO on Main Switch 12 Way Board

Specification

Isolator

RCD

WxHxD Dimensions (mm)

MCB

BOARD-IEC604393 MCB-IEC60898 RCD-IEC61008

100A DP

80A DP 30mA

399x230x120

None

Specification

Isolator

RCD

WxHxD Dimensions (mm)

MCB

Moulded Dual RCD Split Load Units (without MCB) Code

Description

SLRRM66

2x80A RCD 1x100A Main Switch 6+6 MCB on RCD 12 Way Board

BOARD-IEC604393 MCB-IEC60898 RCD-IEC61008

100A DP

80A DP 30mA

399x230x120

None

SLRRM44

2x80A RCD 1x100A Main Switch 4+4 MCB on RCD 8 Way Board

BOARD-IEC604393 MCB-IEC60898 RCD-IEC61008

100A DP

80A DP 30mA

327x230x120

None

“MCB’s supplied separately and as required by customer”.

Please refer to the back page of the catalogue for 17th Edition specification.


SPLIT LOAD

Consumer units Complete with MCB

Accessory Packs Included contains: n Pre-printed circuit identification labels n Blanks n Phase insulator

Catalogue for 2008 - 2009

SLRM55CB

5

Split Load Consumer Units - 10 Way 5+5 c/w MCB - 100A Main Switch & 80Amp 2P RCD 30mA Code

Description

Specification

SLRM55CB

80A RCD 1x100A Main Switch 10-MCB 10 Way Board

Board-IEC604393 MCB-IEC60898 RCD-IEC61008

SLRM55CB/63 **

63A RCD 1x100A Main Switch 10-MCB 10 Way Board

Board-IEC604393 MCB-IEC60898 RCD-IEC61008

Isolator 100A DP

100A DP

RCD 80A DP 30mA

63A DP 30mA

WxHxD Dimensions (mm)

B Type MCB

327x230x120

3x6A MCB 2x16A MCB 4x32A MCB 1x40A MCB

327x230x120

3x6A MCB 2x16A MCB 4x32A MCB 1x40A MCB

32A MCB

30mA RCD

Cooker

Shower

32A MCB

Kitchen sockets

Downstairs Sockets

16A MCB

Upstairs sockets

Immersion Heater

6A MCB

Downstairs Lights

Upstairs Lights

6A MCB

Bathroom Lights

Outside Lights

Typical Example

6A MCB

6A MCB

32A MCB

32A MCB

40A MCB

Main Isolator

With one RCD protected section with MCB’s and RCBO’s on the switch side. ** To special order (available on request). Please refer to the back page of the catalogue for 17th Edition specification.

...affordable quality


Garage & Shower units Complete with MCB (Ready to use)

6

GU563/632

SU363/50

SU363/50

Moulded Garage Units Garage Unit - 5 Way with 63A DP RCD 30mA & MCB

www.ced-elec.co.uk

Code

Description

Specification

Rated

Construction

GU563/632

5 Module 3 Way Moulded Garage Unit c/w 63A DP RCD 30mA 1xB6-MCB & 1B32 – MCB

IEC60439-3

IP55

Moulded ABS base Transparent Polycarbonate Cover

WxHxD Dimensions (mm) 136x184x103

Moulded Shower Unit - 3 Way with 63A DP 30mA RCD & MCB Code

Description

Specification

Rated

Construction

SU363/50

3 Module 1 Way Moulded Shower Unit c/w 63A DP RCD 30mA 1xB50-MCB

IEC60439-3

IP55

Moulded ABS base Transparent Polycarbonate Cover

n RCD to BSEN61008-1 n Terminal Capacity upto 352mm n MCB 6kA IEC60898-1 Single Pole n IP55

WxHxD Dimensions (mm) 100x184x103


SPLIT LOAD

Consumer units

For greater flexibility to suit your own combination of MCB/RCBO

Without MCB

CU14SL

CU18SL

n 10 Way Consumer Unit Split Load -100A

n 14 Way Consumer Unit Split Load -100A

n 18 Way Consumer Unit Split Load -100A

2P Switch 80A - 2P RCD (without MCB) n 6 Spaces for MCB/RCBO

2P Switch 80A - 2P RCD (without MCB)

n 10 Spaces for MCB/RCBO

2P Switch 80A - 2P RCD (without MCB) n 14 Spaces for MCB/RCBO

10 Way Moulded Consumer Unit - Split Load (without MCB) c/w (A) 100A 2P Main Switch (B) 80A 2P - RCD - 30mA Code CU10SL

WxHxD Dimensions (mm)

Specification

Isolator

RCD

Board IEC-60439-3

100A DP IEC60947-3

80A DP 30mA EEC 61008

255x230x120

MCB/RCBO None MCB-IEC 60898 RCBO-IEC61009

7

14 Way Moulded Consumer Unit - Split Load (without MCB) c/w (A) 100A 2P Main Switch (B) 80A 2P - RCD - 30mA CU14SL

Board IEC-60439-3

100A DP IEC60947-3

80A DP 30mA EEC 61008

Catalogue for 2008 - 2009

CU10SL

327x230x120

None MCB-IEC 60898 RCBO-IEC61009

18 Way Moulded Consumer Unit - Split Load (without MCB) c/w (A) 100A 2P Main Switch (B) 80A 2P - RCD - 30mA CU18SL

Board IEC-60439-3

100A DP IEC60947-3

80A DP 30mA EEC 61008

399x230x120

None MCB-IEC 60898 RCBO-IEC61009

Upstairs Lights

Immersion Heater

Downstairs Sockets

Shower

Bathroom Lights

Downstairs Lights

Upstairs sockets

Kitchen sockets

Cooker

30mA RCD

Outside Lights

Typical Example

6A MCB

6A MCB

16A MCB

32A MCB

45A MCB

6A RCBO

6A RCBO

32A RCBO

32A RCBO

40A RCBO

Main Isolator

With one RCD protected section with MCB’s and RCBO’s on the switch side.

N.B. Fitted with continuous Busbar for configuration required by the customer.

...simple & easy to use


MAIN

Consumer units

For low budget and flexible choice of MCB/RCBO

With Main Switch & RCD

Burglar Alarm

Upstairs Lights

Downstairs Lights

Immersion Heater

Kitchen Sockets

Upstairs Sockets

Downstairs Sockets

Shower

Cooker

8

Smoke alarms

Typical Example

6A 30mA RCBO

6A 30mA RCBO

6A 30mA RCBO

6A 30mA RCBO

16A 30mA RCBO

32A 30mA RCBO

32A 30mA RCBO

32A 30mA RCBO

32A 30mA RCBO

40A 30mA RCBO

Main Isolator

Utilising RCBO’s throughout would provide a secure dedicated 30mA protected supply to every circuit.

Moulded Consumer Unit with 80A DP RCD 30mA as Main Switch for Garage Unit or Shower Unit Application (without MCB)

CU4R

Code

Description

Specification

Rated

Construction

CU4R

4 Modules 2 Way Moulded Consumer Unit c/w 80A - DP RCD as Switch (MCB not included)

IEC60439-3

IP20

Moulded ABS Base Transparent Polycarbonate Cover

WxHxD Dimensions (mm)

MCB

145x230x120

None

WxHxD Dimensions (mm)

Vertical Keyhole Distance

Moulded Consumer Unit with 100A - Main Switch as an (Isolator) Code

Description

Specification

Rated

Construction

IP20

Moulded ABS Base Transparent Polycarbonate Cover

145x230x120

168mm

220x230x120

168mm

www.ced-elec.co.uk

CU4S

4 Module 2 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)

IEC60439-3 CE

CU8S

8 Module 6 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)

IEC60439-3 CE

IP20

Moulded ABS Base Transparent Polycarbonate Cover

CU10S

10 Module 8 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)

IEC60439-3 CE

IP20

Moulded ABS Base Transparent Polycarbonate Cover

255x230x120

168mm

CU14S

14 Module 12 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)

IEC60439-3 CE

IP20

Moulded ABS Base Transparent Polycarbonate Cover

327x230x120

168mm

CU18S

18 Module 16 Way Moulded Consumer Unit c/w 100A Switch (MCB not included)

IEC60439-3 CE

IP20

Moulded ABS Base Transparent Polycarbonate Cover

399x230x120

168mm

Metal Consumer Units -100A DP Main Switch - Isolator Code

Description

MCU4S

4 Ways Metal Consumer Unit c/w 100A DP isolator

MCU14S

14 Ways Metal Consumer Unit c/w 100A DP Isolator

MCU4S

Specification

WxHxD Dimensions (mm)

Rated

Construction

IEC60439-3

IP20

Metal sheet grey Epoxy painted base Transparent Polycarbonate Cover

130x190x110

IEC60439-3

IP20

Metal sheet grey Epoxy painted base Transparent Polycarbonate Cover

310x190x110


MCB, RCBO & RCD units

For consumer units

RCD40BR

RCD63BR

MCB

RCBO RCD80BR

RCD25BR

n RCBO is a combination of RCD and MCB n RCBO to IEC61009 n 30mA 6A-40Amp n Single Module n B Type Series

MCB - B Type 6kA SP N.B. All consumer units must be fitted with CED circuit breakers.

Code

Description

CUB6SP

6A-SP MCB - B Type

CUB10SP

10A-SP MCB - B Type

CUB16SP

16A-SP MCB - B Type

CUB20SP

20A-SP MCB - B Type

CUB32SP

32A-SP MCB - B Type

CUB40SP

40A-SP MCB - B Type

CUB50SP

50A-SP MCB - B Type

CUB63SP

63A-SP MCB - B Type

CUBLANK

Blank for Consumer Unit

RCBO 1 Module (single module)

RCBO20

Code

Description

RCBO6

Single Modular RCBO 6A 30mA

RCBO10

Single Modular RCBO 10A 30mA

RCBO16

Single Modular RCBO 16A 30mA

RCBO20

Single Modular RCBO 20A 30mA

RCBO25

Single Modular RCBO 25A 30mA

RCBO32

Single Modular RCBO 32A 30mA

RCBO40

Single Modular RCBO 40A 30mA

Catalogue for 2008 - 2009

n IEC 60898-1 n Breaking Capacity -6kA n B Type Series n Safety Finger Proof Terminals n Terminal Capacity Up To 35mm2 Cable n Various Rating - 6A-63A SP n Protection Against Overload / Short-Circuit n Dimension 40x18x80mm (45mm Projection)

9

RCD Sockets Code

Description

RCDMSSK2

RCD Metal Clad Twin Switched Socket

RCDSK2

RCD Twin Unswitched Socket

RCDSK2

RCDMSSK2

...affordable quality


RCD & Busbar

RCD (Residual Current Devices)

For consumer units

n BSEN61008-1 n RCD - Prevent fatal electric shock on a person by reducing to “safe” levels the value and the time a person is exposed to current flowing through the body n RCD - Protect plant & machinery from fire by a current passing from live to earth that a fuse or circuit break may not detect n RCD should be used along with MCB to detect, short circuit and overload current n 30mA Trip Double Pole n 25A -80Amp options n Available in 2 Pole

10

2 Pole RCD 25A-80A Code

Description

Poles

Sensitivity

RCD25BR

25A DP RCD 30mA

2

30mA

RCD40BR

40A DP RCD 30mA

2

30mA

RCD63BR

63A DP RCD 30mA

2

30mA

RCD80BR

80A DP RCD 30mA

2

30mA

Busbar for Split Load/Standard Consumer Units Code

Description

BB3

Busbar for 3 Way

Dimensions (mm) -

BB10

Busbar for 10 Way

206x28x2

BB14

Busbar for 14 Way

278x28x2

BB18

Busbar for 18 Way

366x28x2

MOULDED

Wall Mounted Enclosures For RCD / MCB

General Features www.ced-elec.co.uk

n IMQ, IEC670-1,94 Double Insulated n Colour - Standard (RAL7035) - White n Material - Insulating and self extinguishing (ABS) material for longer life n Temperature - (-15°C to + 60°C)

Weatherproof Moulded Enclosures

n Approval IP55 n Surface Mounting with hinged lid (clear tinge of Blue) n Suitable for interior and exterior use

Moulded Enclosures

n Approval IP44 n Surface Mounting - Open type n Suitable for indoor use

PE2

PE4

Moulded Wall Mounted (ABS) Enclosures for RCD/CB CE IMQ Approved

PE6

Modules

Rated

WxHxD Dimensions (mm)

No. Knockouts

Fixing Centre (mm)

PVC Enclosure with Lid

3

IP55

83x175x114

1 (each side)

131

PVC Enclosure with Lid

5

IP55

125x175x114

2 (each side) 2 (top & bottom)

131

-

-

Code

Description

PE3WP PE5WP

Moulded Wall Mounted (ABS) Enclosures for RCD/CB PE2

PVC Enclosure

2

IP44

51x130x 60

PE4

PVC Enclosure

4

IP44

88x130x60

-

-

140x165x72

2 (each side) 2 (top & bottom)

-

PE6

PE5WP

PVC Enclosure

6

IP44


CED Consumer Units and the 17th Edition Under the 17th edition wiring regulations (from January 2008) the following will apply to all domestic and residential installations.

Note: Additional protection is provided as additional protection. It does not obviate the need for circuit protection by circuit breakers or fuses. 1. Regulation 411.3.3 socket outlets with rated current not exceeding 20A that are for general use by ordinary persons. 2. Regulation 701.411.3.3 Additional protection shall be provided for all circuits of the location by use of one or more 30mA RCD. 3. Regulations 522.6.6 522.6.7 522.6.8 cables concealed in a wall or partition at less than 50mm depth and without earthed mechanical protection e.g. conduit. 4. Regulation 314.1 Every installation shall be divided into circuits as necessary to avoid danger and inconvenience in the event of a fault. Take account of danger that may arise from failure of a single such as a lighting circuit, reduce the possibility of unwanted tripping of RCD etc. 4. Regulation 314.2 Separate circuits to be provided for parts of the installation that need to be separately controlled in such a way that those circuits are not affected by the failure of other circuits.

Catalogue for 2008 - 2009

1. All socket outlets should be protected by 30mA RCD whether on ground floor of a house or the top floor of high rise apartment block. 2. All circuits in a room with a fixed bath or shower should be protected by one or more 30mA RCD’s. 2. All cables concealed in metal stud partitions (common in new build) should be protected by 30mA RCD’s. 3. All cables buried beneath the plaster surface of a wall or partition (at less than 50mm) should be protected by 30mA RCD’s. 4. Installations should be divided up into circuits so as to take account of danger and inconvenience caused by a single fault - e.g. such as a lighting circuit. 4. Installations should be designed and arranged so as to prevent unwanted tripping of the RCD’s.

REGULATION SUMMARY Regulation

Relating To

Examples

Additional Protection

Sockets up to 20A rating for general use by ordinary persons

Upstairs Sockets Downstairs Sockets Kitchen Sockets Cooker Outlets with Integral 13A Socket Garage Sockets Plus and other sockets up to 20A rated

30mA RCD

701.411.3.3

All circuits in a room with a fixed bath or shower

Shower Circuit Lighting Circuit Heating Circuit Ventilation Circuit Shaver Socket Plus other Circuits

30mA RCD

522.6.6 522.6.7 and 522.6.8

All circuits buried in a wall or partition at less than 50mm and without mechanical protection

Downstairs Lighting Upstairs Lighting Immersion Heater Burglar Alarms Smoke Alarms Plus other circuits

30mA RCD

411.3.3

11

British Standards and IEE regulations are subject to change and amendments. This guide is not a substitute for the regulations which should always be used for all types of electrical installation work.

Key symbols used for codes n SL = Split Load n CU = Consumer Unit n R = RCD n M = Main Switch n S = Main Switch

...simple & easy to use


Introducing our new 2008/2009 catalogue for our completely new range of Consumer Units, specifically manufactured to meet the very high standards required by electricians and structural engineers. Designed to provide the widest versatility whilst being robust and durable.

Intr odu a com cing our plet new inst ely 200 rum new 7/2 ents 008 ver , spe range y high of pro catalogu cific stan ally fess igne dar iona e with ds req manuf d to l test actu pro y to uire vide red use d by to me the feat elec high ure et tric s. est al eng the acc ura cy with ineers. ma ny

Des

Guid

e

eas

RS

cif Spe &

08

SITE EL

Ca

- 20

.uk

08

RM8 1RX (England)

11/07/2007 12:15:35

Sou rce Fo r c tr ic

- 2008

E le

r 2007

- 2008

g le

gue fo

12:15: 35

r 2007

in AS

11/07/ 2007

S

Catalo

www.ced-elec.c

2-3

ECTRIC

gue fo

Branch Stamp:

Dagenham Essex

Road, 020 8503 8900 8503 8500 - Facsimile. Telephone. 020 - email. info@ced-elec.co.uk o.uk

44-48 Freshwater

Tester Cover2.indd

Catalo

07

.co LIGHT METERS

20

lec

p:

for

RS

ch Stam

ue

TE

Bran

0

talog

ME

ced-e

HT

w.

LIG

www.ced-elec.co.uk

ww

ers Buy

Pro Test fessio Inst nal rum ents

2007 - 2008

- 20

ional Profess uments tr s Test In 2007 - 2008

07

2-3

Catalogue for

20

48

2.indd

Professional s Test Instrument

S

for

CLAMP METERS

44-

Cover

ER

ue

CL AM P ME TE RS VOLTAGE TESTERS

Teleph Freshwa w.c one. ter Roa ed020 d, Dag elec enh .co 8503 .uk am - em 8500 Ess ex ail. info - Facsim RM8 @c ile. 1RX (En edelec .co 020 850 gland) .uk 3 890

ww Tester

ET

Catalogue for

iers

IM

MULTIMETE

talog

s!

LT

Ca

l pr

ct odu

www.ced-elec.co.uk

ca ctri

IO N

MU

.uk

D IT 5E

.co

Ele

200

lec

S

Y

ced-e

gle

AR

w.

in AS

ce our

Fo r

RU

catalogue with VO new 2007/2008 LT Introducing our test AG range of professional E TE a completely new to meet the manufacturedST ER S instruments, specifically engineers. required by electrical very high standards with many the highest accuracy Designed to provide easy to use features.

ww

FEB

2 N O.

rod al P u c ts !

www.c ed-ele c.co.u

CED CTR

k

ELE IC A L EB -F RU AR Y

RX. 900 81 8 RM 503 8 ex E s s ( 0 2 0 ) .c o .u k m c a . e n h s im il e c e d - e le g a ,D Fa c fo @ o a d 5 0 0 a il . in rR 8 ate 503 k - Em 8 .u shw Fr e ( 0 2 0 ) e le c .c o 8 4 . 4 4 - h o n e w w.c e d p Te leb s it e . w

200 D IT 5E IO N

N O. 2

500 38 0 850 0 890 2 0 503 ne 8 o h ep 020 Te l ile sim Fac

We

ED C

2 | 00

| 05

Other material We have a range of literature that we have produced including:LED Lighting, Site Electric’s, Professional Test Instruments and our Main Catalogue all of which can be requested. If you require a copy then please contact us at the address below.

www.ced-elec.co.uk Branch Stamp:

44-48 Freshwater Road, Dagenham Essex RM8 1RX (England)

Telephone. 020 8503 8500 Facsimile. 020 8503 8900

www.ced-elec.co.uk - email. info@ced-elec.co.uk CED | edc1301 | 08/09


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.