BLUEKIT速 VENTILATION FLAPS
w w w.b l u ek i t .e u
1
Horizontal mounting into the shaft/the roof
Vertical mounting into the shaft/ the facade
5 4 3 2 1
2
EN_BLUEKIT_VENTILATIONFLAPS_20150526
Summary New building.................................................................. 4 Horizontal mounting........................................................... 4
Ventilation flap JK-180 HV............................................. 4
Roof vent JK-180 HVC..................................................... 6
Roof vent with blades JK-180 HVL................................... 8
Thermo Flap TF............................................................. 10
Vertical mounting............................................................... 12
Ventilation flap with weather protection grilles ALAS .. 12
Insulated Louvre Windows .......................................... 14
S9iVt-05 LF-MR........................................................ 14
Choosing the best solution for ventilation flaps is determining for ventilation regulation and optimization. They are crucial for the execution of an efficient energetic concept and contribute to the decrease of building operating costs. It is possible to combine to our BlueKit速 system, Louvre Windows or ventilation flaps which are in accordance with EN 12101-2 certified, together or without protection accessories such as weather protection grilles or roof window.
Tairmo-LF-MR......................................................... 14
Modernisation............................................................... 16 Horizontal and vertical mounting...................................... 16
JK-190............................................................................ 16
Horizontal mounting........................................................... 18
JK-190 Side-corner mounting (accessories).................. 18
3
Horizontal C E RT I F I E D N
E
JK-180 HV
after
12101-
2
NEW BUILDING
The most efficient solution for new buildings Product • Flush installation • Easy connection to exterior ventilation shaft • Possible combination with roof window • Easy installing, easy access to motor • To choose from : spring return actuator or direct current
Ventilation flap Features : • Louvres made of aluminum profile, flow- favouring and torsion-resistant • Seals in reinforced rubber • Profiled sheet steel frame galvanized 1.5 mm, dimensionally stable • Delivered and assembled with profiled mounting plate • Pre-assembled and pre-cabled motor : life length certified for 60.000 cycles • Motor cabling with RJ45 connector for easy connection to BlueKit® system • Motor with positive safety functioning in case of power failure
4
MOUNTING Adjustment in the opening thanks to the mounting plate; possible mounting from outside or from the lift shaft.
NEW BUILDING
Horizontal
JK-180 HV
Drawings and dimensions MOUNTING FROM THE ROOF Concrete ceiling
Concrete ceiling
Section B-B
Section A-A
MOUNTING FROM THE SHAFT Concrete ceiling
Concrete ceiling
Section B-B
Section A-A
JK-180 HV Designation according to the 360x360 ventilation flap opening (mm) BxH
530x530
700x700
0,23
0,41
Opening dimensions (mm) B1xH1 590x450
760x620
930x790
Mounting plate dimensions (mm) B2xH2 740x600
910x770
1080x940 1240x1100 1410x1270 1580x1440
Net ventilation surface (m2)
0,10
860x860 1030x1030 1200x1200 0,62
0,90
1,22
1090x950 1260x1120 1430x1290
5
Horizontal
JK-180 HVC
E
C E RT I F I E D N after 12101
2
NEW BUILDING
Optimum insulation and protection under all weather conditions Product • Integration to thermal insulation • Protection against bad weather • Complete and built-in solution • Hygienic and energetic optimized • Prevents from condensation
Ventilation flap and roof vent Features Ventilation flap JK-180 HV (see page 4) Roof vent: • Connector base to ventilation flap for flat roof • Protects from rain • Condensate recovery and evacuation • Material: steel galvanized sheet (Ref. JK-180 HVC-S) or aluminum (Ref. JK-180 HVC-A) • Thickness: 1,2mm • Production: spot welding for the base plate – spot welding and riveting for the cover
MOUNTING • Mounting of the ventilation flap from outside or inside the shaft • Integration of the base plate during building insulation* • Connection of ventilation flap (reference JK-180 HV) to the base plate thanks to predrilled holes • Cover set up *The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional tasks.
6
NEW BUILDING
Horizontal
JK-180 HVC
Drawings and dimensions Section B-B
Section A-A
Condensate outlet nozzle
Flat roof upper layer Roof sealing Thermal insulation
Concret ceiling
JK-180 HVC Designation according to the 360x360 ventilation flap opening (mm) BxH
530x530
700x700
0,23
0,41
Opening dimensions (mm) B1xH1 590x450
760x620
930x790
Mounting plate dimensions (mm) B2xH2 740x600
910x770
1080x940 1240x1100 1410x1270 1580x1440
Net ventilation surface (m2)
0,10
Cover dimensions B3xH3 890x750
860x860 1030x1030 1200x1200 0,62
0,90
1,22
1090x950 1260x1120 1430x1290
1060x920 1230x1090 1490x1350 1660x1520 1930x1790
Base plate height (mm) L1
500
500
500
500
500
500
Cover height (mm) L2
250
250
250
300
350
400
Overall height of the roof vent (mm) L3
750
750
750
800
850
900
7
Horizontal
JK-180 HVL
C E RT I F I E D E
N
Compact solution for optimal insulation and protection
after
12101-
2
NEW BUILDING
Product • Integration to thermal insulation • Complete and built-in solution • Compact solution: ideal to optimize space • Hygienic and energetic optimized • Prevents from condensation
Ventilation flap and roof vent with blades Features Ventilation flap JK-180 HV (see page 4) Roof vent with blades : • Base plate for flat roof with interface to connect ventilation flap • Protects from rain • Ideal when lack of space : the louvre cover dimensions correspond to the base plate dimensions • Condensate recovery and evacuation • Material: steel galvanized sheet (Ref. JK-180 HVL-S) or aluminum (Ref. JK-180 HVL-A) • Production: spot welding
MOUNTING • Mounting of the ventilation flap from outside or inside the shaft • Integration of the base plate during building insulation* • Connection of ventilation flap (reference JK180 HV) to the base plate thanks to pre-drilled holes • Cover set up *The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional tasks.
8
NEW BUILDING
Horizontal
JK-180 HVL
Drawings and dimensions Section B-B
Section A-A
Condensate outlet nozzle
Flat roof upper layer Roof sealing Thermal insulation
Concrete ceiling
JK-180 HVL Designation according to the 360x360 ventilation flap opening (mm) BxH
530x530
700x700
0,23
0,41
Opening dimensions (mm) B1xH1 590x450
760x620
930x790
Mounting plate dimensions (mm) B2xH2 740x600
910x770
1080x940 1240x1100 1410x1270 1580x1440
Cover dimensions (mm) B3xH3 690x550
860x720
1030x890 1190x1050 1360x1220 1530x1390
Net ventilation surface (m2)
0,10
860x860 1030x1030 1200x1200 0,62
0,90
1,22
1090x950 1260x1120 1430x1290
Base plate height (mm) L1
500
500
500
500
500
500
Cover height (mm) L2
320
320
320
385
450
515
Overall height of the roof vent (mm) L3
770
770
770
835
900
965 9
Horizontal
The all-in-one solution with insulation
C E RT I F I E D N
E
TF (Thermo Flap)
after
12101-
2
NEW BUILDING
Product • Integration to thermal insulation • Built-in solution • Ventilation opening on 4 sides • The insulated base plate prevents from condensate • Ventilation and smoke extraction assured regardless of wind direction • Excellent heat transfer coefficient
Base plate in fiberglass (GRP), Louvre windows + cover with blades Features : • Base plate in fiberglass combined with a Louvre window • Louvre window with electric motor • Cover with blades protecting against bad weather and with ventilation on 4 sides • Ideal when lack of space : the Louvre cover dimensions correspond to the base plate dimensions • Insect-proof • Resistant
MOUNTING Integration of the base plate during building insulation* MAINTENANCE Visual maintenance from the shaft, easy access from the roof in case of repair. *The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional tasks.
10
NEW BUILDING
Horizontal
TF (Thermo Flap) Drawings and dimensions
Section B-B
Section A-A
450x450mm - 1 blade
600x600mm - 2 blades
Flat roof upper layer Roof sealing Thermal Insulation Concrete ceiling
800x800mm - 3 blades
TF Designation according to the opening dimensions (mm) BxH
450x450
600x600
800x800
0,10
0,20
0,39
Base plate dimensions (mm) B1xH1
810x810
960x960
1160x1160
Cover dimensions (mm) B2xH2
595x630
745x780
950x985
Base plate height (mm) L1
500
500
500
Cover height (mm) L2
332
332
385
Thermo Flap overall height (mm) L3
789
789
842
U-Value (W/m²K)
0,41
0,46
0,55
Number of blades
1
2
3
Net ventilation surface (m2)
11
Vertical
C E RT I F I E D N
E
JK-180 HV-ALAS
after
12101-
2
NEW BUILDING
Vertical ventilation and protection, quite simply! Product • Flush installation • Integration to the building thermal insulation • Easy installation from the shaft or the machine room
Ventilation flap with weather protection grille Features Ventilation flap JK-180 HV (see page 4) Weather protection grille ALAS: • Ventilation grille with fixed rain-repellent blades preventing the ingress of rain or snow into the ducting system. A grid (fixed behind) protects against intrusion of birds. • Blades : galvanised steel • Grid : galvanised steel • Mounting feet MOUNTING Vertical mounting in the wall shaft or in the machine room. Mounting of the ventilation flap and weather protection grille in the ventilation opening. Mounting from the shaft, thanks to the mounting plate of the ventilation flap and the grille mounting feet.
12
NEW BUILDING
Vertical
JK-180 HV-ALAS Drawings and dimensions Mounting plate B2xH2
Opening dimensions B1xH1
Inside view
Inside
Outside
BxH
Inside
Flap opening
Outside
Flap Frame
Outside view
Section
Alternative section
JK-180 HV-ALAS Designation according to the 360x360 ventilation flap opening (mm) BxH
530x530
700x700
0,23
0,38
Opening dimensions (mm) B1 x H1 590x450
760x620
930x790
Mounting plate dimensions (mm) B2 x H2 740x600
910x770
1080x940 1240x1100 1410x1270 1580x1440
Net ventilation surface (m2)
0,10
860x860 1030x1030 1200x1200 0,56
0,77
1,03
1090x950 1260x1120 1430x1290
13
N
after
12101-
2
Vertical
E
NEW BUILDING
C E RT I F I E D
S9-iVt-05 LF-MR and Tairmo-LF-MR Combine ventilation, energetic efficiency and modern design Product • Flush installation • Integration to the building thermal insulation • Excellent thermal performance :low coefficient of the glass heat permeability (coef. Ug/Up/Uw) • Anti breakage • Mounting time reduced
S9-iVt-05
Louvre window Features • Aluminum profiles, thermally broken • Glass blade frame (Tairmo) or sandwich panels* (S9-iVt-05) • Air permeability, water tightness and heat protection • Anodised/powder coated • Double or triple glazing • Electric motor: 24VDC • Opening angles: Maxi 90° (Tairmo) Maxi 84° (S9-iVt-05) *S9-iVt-05 blades available in glass also upon request
14
Tairmo MOUNTING Vertical flush mounting in the wall shaft. The installation is done from the shaft thanks to mounting feet or a specific mounting plate.
NEW BUILDING
Vertical
S9-iVt-05 LF-MR and Tairmo-LF-MR Drawings and dimensions
Inside
Outside
Outside view
S9-iVt-05 LF-MR Designation according to the 420x420 630x390 570x570 775x775 element dimensions BxH Net ventilation surface (m2)
0,1
0,15
0,2
0,39
Opening dimensions (mm) B1xH1 450x450 660x420 600x600 805x805 Panel Up-Value (W/m²K)
1,0
1,0
1,0
1,0
Coef. Uw (W/m K)
2,5
2,3
2,3
2,1
Number of blades
1
1
2
3
2
Section
Inside
Outside
Outside view
Tairmo-LF-MR Designation according to the 800x350 590x505 740x505 815x815 element dimensions BxH Net ventilation surface (m2)
0,11
0,15
0,20
0,40
Opening dimensions (mm) B1xH1 830x380 620x535 770x535 845x845 Coef. Ug (W/m2 K)
0,7
0,7
0,7
0,7
Coef. Uw (W/m K)
1,9
1,8
1,7
1,6
Number of blades
1
1
1
2
2
Section
15
C E RT I F I E D N
E
JK-190
Horizontal/Vertical after
12101-
2
MODERNISATION
The flexible solution for modernisations Product • Non-integrated solution – Surface mounting • Do not decrease the ventilation surface • Can be adapted to all openings • Easy ventilation flap mounting and motor maintenance
Ventilation flap Features • Louvres made of aluminum profile, flow-favouring and torsion-resistant • Seals in reinforced rubber • Profiled sheet steel frame galvanized 1.5 mm, dimensionally stable • Pre-assembled and pre-cabled motor : life length certified for 60.000 cycles • Motor cabling with RJ45 connector for easy connection to BlueKit® system • Motor with positive safety functioning in case of power failure • The additional 10 mm depth of the frame allows a wider ventilation surface (free movement of the blades and airflow increase between the blades)
16
MOUNTING • Fixing in the wall or the lift shaft slab thanks to the mounting frame. • On both sides, the ventilation flap openings must be superior by a minimum of 30 mm of the ventilation openings. • Installation possible in a corner with a specific mounting angle (sold as an accessory – see page 18)
MODERNISATION
JK-190
Horizontal/Vertical
Drawings and dimensions Section A-A
Section B-B
Concrete ceiling
Concrete ceiling
JK-190*
Ventilation flap opening (mm) H/B
360
530
700
860
1030
1200
360
0,1
0,15
0,2
0,25
0,3
0,35
530
0,16
0,23
0,3
0,37
0,45
0,52
700
0,21
0,31
0,41
0,5
0,6
0,7
860
0,26
0,38
0,51
0,62
0,75
0,87
1030
0,31
0,46
0,61
0,75
0,9
1,04
1200
0,37
0,54
0,71
0,87
1,05
1,22
*Standard dimensions in grey
17
Horizontal
JK-190 Slab/Corner
C E RT I F I E D E
N
after
12101-
2
MODERNISATION
Accessories for horizontal mounting Produkt • Ventilation flap JK-190 with mounting angles • Solution for the ventilation flap mounting in a corner of the shaft slab when space for fixing is not sufficient
Ventilation Flap + mounting angles MOUNTING • Flexible mounting according to the access to the ventilation opening 3 mounting angles: • Fixing of angle corner 1 to the ventilation flap together with the supplied nuts • Positioning of the ventilation flap including mounting angle 1 in front of the opening and screwmounting in the shaft slab • Positioning of mounting angle 2 on the ventilation flap and screwmounting in the shaft wall
1
2
18
2
MODERNISATION
Horizontal
JK-190 Slab/Corner Drawings and dimensions with mounting angles
Section B-B
Section A-A
1
2
2
Corner view / shaft headroom
1
2
19
20
FURTHER INFORMATION
INTELLIGENT LIFT SHAFT SYSTEMS
w w w. bluekit .eu
EUROPE-WIDE AVAILABLE