w w w.b l u ek i t .e u

1


Horizontal mounting into the shaft/the roof

Vertical mounting into the shaft/ the facade

5 4 3 2 1

2

EN_BLUEKIT_VENTILATIONFLAPS_20150526


Summary New building.................................................................. 4 Horizontal mounting........................................................... 4

Ventilation flap JK-180 HV............................................. 4

Roof vent JK-180 HVC..................................................... 6

Roof vent with blades JK-180 HVL................................... 8

Thermo Flap TF............................................................. 10

Vertical mounting............................................................... 12

Ventilation flap with weather protection grilles ALAS .. 12

Insulated Louvre Windows .......................................... 14

S9iVt-05 LF-MR........................................................ 14

Choosing the best solution for ventilation flaps is determining for ventilation regulation and optimization. They are crucial for the execution of an efficient energetic concept and contribute to the decrease of building operating costs. It is possible to combine to our BlueKit速 system, Louvre Windows or ventilation flaps which are in accordance with EN 12101-2 certified, together or without protection accessories such as weather protection grilles or roof window.

Tairmo-LF-MR......................................................... 14

Modernisation............................................................... 16 Horizontal and vertical mounting...................................... 16

JK-190............................................................................ 16

Horizontal mounting........................................................... 18

JK-190 Side-corner mounting (accessories).................. 18

3


Horizontal C E RT I F I E D N

E

JK-180 HV

after

12101-

2

NEW BUILDING

The most efficient solution for new buildings Product • Flush installation • Easy connection to exterior ventilation shaft • Possible combination with roof window • Easy installing, easy access to motor • To choose from : spring return actuator or direct current

Ventilation flap Features : • Louvres made of aluminum profile, flow- favouring and torsion-resistant • Seals in reinforced rubber • Profiled sheet steel frame galvanized 1.5 mm, dimensionally stable • Delivered and assembled with profiled mounting plate • Pre-assembled and pre-cabled motor : life length certified for 60.000 cycles • Motor cabling with RJ45 connector for easy connection to BlueKit® system • Motor with positive safety functioning in case of power failure

4

MOUNTING Adjustment in the opening thanks to the mounting plate; possible mounting from outside or from the lift shaft.


NEW BUILDING

Horizontal

JK-180 HV

Drawings and dimensions MOUNTING FROM THE ROOF Concrete ceiling

Concrete ceiling

Section B-B

Section A-A

MOUNTING FROM THE SHAFT Concrete ceiling

Concrete ceiling

Section B-B

Section A-A

JK-180 HV Designation according to the 360x360 ventilation flap opening (mm) BxH

530x530

700x700

0,23

0,41

Opening dimensions (mm) B1xH1 590x450

760x620

930x790

Mounting plate dimensions (mm) B2xH2 740x600

910x770

1080x940 1240x1100 1410x1270 1580x1440

Net ventilation surface (m2)

0,10

860x860 1030x1030 1200x1200 0,62

0,90

1,22

1090x950 1260x1120 1430x1290

5


Horizontal

JK-180 HVC

E

C E RT I F I E D N after 12101

2

NEW BUILDING

Optimum insulation and protection under all weather conditions Product • Integration to thermal insulation • Protection against bad weather • Complete and built-in solution • Hygienic and energetic optimized • Prevents from condensation

Ventilation flap and roof vent Features Ventilation flap JK-180 HV (see page 4) Roof vent: • Connector base to ventilation flap for flat roof • Protects from rain • Condensate recovery and evacuation • Material: steel galvanized sheet (Ref. JK-180 HVC-S) or aluminum (Ref. JK-180 HVC-A) • Thickness: 1,2mm • Production: spot welding for the base plate – spot welding and riveting for the cover

MOUNTING • Mounting of the ventilation flap from outside or inside the shaft • Integration of the base plate during building insulation* • Connection of ventilation flap (reference JK-180 HV) to the base plate thanks to predrilled holes • Cover set up *The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional tasks.

6


NEW BUILDING

Horizontal

JK-180 HVC

Drawings and dimensions Section B-B

Section A-A

Condensate outlet nozzle

Flat roof upper layer Roof sealing Thermal insulation

Concret ceiling

JK-180 HVC Designation according to the 360x360 ventilation flap opening (mm) BxH

530x530

700x700

0,23

0,41

Opening dimensions (mm) B1xH1 590x450

760x620

930x790

Mounting plate dimensions (mm) B2xH2 740x600

910x770

1080x940 1240x1100 1410x1270 1580x1440

Net ventilation surface (m2)

0,10

Cover dimensions B3xH3 890x750

860x860 1030x1030 1200x1200 0,62

0,90

1,22

1090x950 1260x1120 1430x1290

1060x920 1230x1090 1490x1350 1660x1520 1930x1790

Base plate height (mm) L1

500

500

500

500

500

500

Cover height (mm) L2

250

250

250

300

350

400

Overall height of the roof vent (mm) L3

750

750

750

800

850

900

7


Horizontal

JK-180 HVL

C E RT I F I E D E

N

Compact solution for optimal insulation and protection

after

12101-

2

NEW BUILDING

Product • Integration to thermal insulation • Complete and built-in solution • Compact solution: ideal to optimize space • Hygienic and energetic optimized • Prevents from condensation

Ventilation flap and roof vent with blades Features Ventilation flap JK-180 HV (see page 4) Roof vent with blades : • Base plate for flat roof with interface to connect ventilation flap • Protects from rain • Ideal when lack of space : the louvre cover dimensions correspond to the base plate dimensions • Condensate recovery and evacuation • Material: steel galvanized sheet (Ref. JK-180 HVL-S) or aluminum (Ref. JK-180 HVL-A) • Production: spot welding

MOUNTING • Mounting of the ventilation flap from outside or inside the shaft • Integration of the base plate during building insulation* • Connection of ventilation flap (reference JK180 HV) to the base plate thanks to pre-drilled holes • Cover set up *The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional tasks.

8


NEW BUILDING

Horizontal

JK-180 HVL

Drawings and dimensions Section B-B

Section A-A

Condensate outlet nozzle

Flat roof upper layer Roof sealing Thermal insulation

Concrete ceiling

JK-180 HVL Designation according to the 360x360 ventilation flap opening (mm) BxH

530x530

700x700

0,23

0,41

Opening dimensions (mm) B1xH1 590x450

760x620

930x790

Mounting plate dimensions (mm) B2xH2 740x600

910x770

1080x940 1240x1100 1410x1270 1580x1440

Cover dimensions (mm) B3xH3 690x550

860x720

1030x890 1190x1050 1360x1220 1530x1390

Net ventilation surface (m2)

0,10

860x860 1030x1030 1200x1200 0,62

0,90

1,22

1090x950 1260x1120 1430x1290

Base plate height (mm) L1

500

500

500

500

500

500

Cover height (mm) L2

320

320

320

385

450

515

Overall height of the roof vent (mm) L3

770

770

770

835

900

965 9


Horizontal

The all-in-one solution with insulation

C E RT I F I E D N

E

TF (Thermo Flap)

after

12101-

2

NEW BUILDING

Product • Integration to thermal insulation • Built-in solution • Ventilation opening on 4 sides • The insulated base plate prevents from condensate • Ventilation and smoke extraction assured regardless of wind direction • Excellent heat transfer coefficient

Base plate in fiberglass (GRP), Louvre windows + cover with blades Features : • Base plate in fiberglass combined with a Louvre window • Louvre window with electric motor • Cover with blades protecting against bad weather and with ventilation on 4 sides • Ideal when lack of space : the Louvre cover dimensions correspond to the base plate dimensions • Insect-proof • Resistant

MOUNTING Integration of the base plate during building insulation* MAINTENANCE Visual maintenance from the shaft, easy access from the roof in case of repair. *The mounting of the roof vent can easily be done by a roofer but should not be part of the lift professional tasks.

10


NEW BUILDING

Horizontal

TF (Thermo Flap) Drawings and dimensions

Section B-B

Section A-A

450x450mm - 1 blade

600x600mm - 2 blades

Flat roof upper layer Roof sealing Thermal Insulation Concrete ceiling

800x800mm - 3 blades

TF Designation according to the opening dimensions (mm) BxH

450x450

600x600

800x800

0,10

0,20

0,39

Base plate dimensions (mm) B1xH1

810x810

960x960

1160x1160

Cover dimensions (mm) B2xH2

595x630

745x780

950x985

Base plate height (mm) L1

500

500

500

Cover height (mm) L2

332

332

385

Thermo Flap overall height (mm) L3

789

789

842

U-Value (W/m²K)

0,41

0,46

0,55

Number of blades

1

2

3

Net ventilation surface (m2)

11


Vertical

C E RT I F I E D N

E

JK-180 HV-ALAS

after

12101-

2

NEW BUILDING

Vertical ventilation and protection, quite simply! Product • Flush installation • Integration to the building thermal insulation • Easy installation from the shaft or the machine room

Ventilation flap with weather protection grille Features Ventilation flap JK-180 HV (see page 4) Weather protection grille ALAS: • Ventilation grille with fixed rain-repellent blades preventing the ingress of rain or snow into the ducting system. A grid (fixed behind) protects against intrusion of birds. • Blades : galvanised steel • Grid : galvanised steel • Mounting feet MOUNTING Vertical mounting in the wall shaft or in the machine room. Mounting of the ventilation flap and weather protection grille in the ventilation opening. Mounting from the shaft, thanks to the mounting plate of the ventilation flap and the grille mounting feet.

12


NEW BUILDING

Vertical

JK-180 HV-ALAS Drawings and dimensions Mounting plate B2xH2

Opening dimensions B1xH1

Inside view

Inside

Outside

BxH

Inside

Flap opening

Outside

Flap Frame

Outside view

Section

Alternative section

JK-180 HV-ALAS Designation according to the 360x360 ventilation flap opening (mm) BxH

530x530

700x700

0,23

0,38

Opening dimensions (mm) B1 x H1 590x450

760x620

930x790

Mounting plate dimensions (mm) B2 x H2 740x600

910x770

1080x940 1240x1100 1410x1270 1580x1440

Net ventilation surface (m2)

0,10

860x860 1030x1030 1200x1200 0,56

0,77

1,03

1090x950 1260x1120 1430x1290

13


N

after

12101-

2

Vertical

E

NEW BUILDING

C E RT I F I E D

S9-iVt-05 LF-MR and Tairmo-LF-MR Combine ventilation, energetic efficiency and modern design Product • Flush installation • Integration to the building thermal insulation • Excellent thermal performance :low coefficient of the glass heat permeability (coef. Ug/Up/Uw) • Anti breakage • Mounting time reduced

S9-iVt-05

Louvre window Features • Aluminum profiles, thermally broken • Glass blade frame (Tairmo) or sandwich panels* (S9-iVt-05) • Air permeability, water tightness and heat protection • Anodised/powder coated • Double or triple glazing • Electric motor: 24VDC • Opening angles: Maxi 90° (Tairmo) Maxi 84° (S9-iVt-05) *S9-iVt-05 blades available in glass also upon request

14

Tairmo MOUNTING Vertical flush mounting in the wall shaft. The installation is done from the shaft thanks to mounting feet or a specific mounting plate.


NEW BUILDING

Vertical

S9-iVt-05 LF-MR and Tairmo-LF-MR Drawings and dimensions

Inside

Outside

Outside view

S9-iVt-05 LF-MR Designation according to the 420x420 630x390 570x570 775x775 element dimensions BxH Net ventilation surface (m2)

0,1

0,15

0,2

0,39

Opening dimensions (mm) B1xH1 450x450 660x420 600x600 805x805 Panel Up-Value (W/m²K)

1,0

1,0

1,0

1,0

Coef. Uw (W/m K)

2,5

2,3

2,3

2,1

Number of blades

1

1

2

3

2

Section

Inside

Outside

Outside view

Tairmo-LF-MR Designation according to the 800x350 590x505 740x505 815x815 element dimensions BxH Net ventilation surface (m2)

0,11

0,15

0,20

0,40

Opening dimensions (mm) B1xH1 830x380 620x535 770x535 845x845 Coef. Ug (W/m2 K)

0,7

0,7

0,7

0,7

Coef. Uw (W/m K)

1,9

1,8

1,7

1,6

Number of blades

1

1

1

2

2

Section

15


C E RT I F I E D N

E

JK-190

Horizontal/Vertical after

12101-

2

MODERNISATION

The flexible solution for modernisations Product • Non-integrated solution – Surface mounting • Do not decrease the ventilation surface • Can be adapted to all openings • Easy ventilation flap mounting and motor maintenance

Ventilation flap Features • Louvres made of aluminum profile, flow-favouring and torsion-resistant • Seals in reinforced rubber • Profiled sheet steel frame galvanized 1.5 mm, dimensionally stable • Pre-assembled and pre-cabled motor : life length certified for 60.000 cycles • Motor cabling with RJ45 connector for easy connection to BlueKit® system • Motor with positive safety functioning in case of power failure • The additional 10 mm depth of the frame allows a wider ventilation surface (free movement of the blades and airflow increase between the blades)

16

MOUNTING • Fixing in the wall or the lift shaft slab thanks to the mounting frame. • On both sides, the ventilation flap openings must be superior by a minimum of 30 mm of the ventilation openings. • Installation possible in a corner with a specific mounting angle (sold as an accessory – see page 18)


MODERNISATION

JK-190

Horizontal/Vertical

Drawings and dimensions Section A-A

Section B-B

Concrete ceiling

Concrete ceiling

JK-190*

Ventilation flap opening (mm) H/B

360

530

700

860

1030

1200

360

0,1

0,15

0,2

0,25

0,3

0,35

530

0,16

0,23

0,3

0,37

0,45

0,52

700

0,21

0,31

0,41

0,5

0,6

0,7

860

0,26

0,38

0,51

0,62

0,75

0,87

1030

0,31

0,46

0,61

0,75

0,9

1,04

1200

0,37

0,54

0,71

0,87

1,05

1,22

*Standard dimensions in grey

17


Horizontal

JK-190 Slab/Corner

C E RT I F I E D E

N

after

12101-

2

MODERNISATION

Accessories for horizontal mounting Produkt • Ventilation flap JK-190 with mounting angles • Solution for the ventilation flap mounting in a corner of the shaft slab when space for fixing is not sufficient

Ventilation Flap + mounting angles MOUNTING • Flexible mounting according to the access to the ventilation opening 3 mounting angles: • Fixing of angle corner 1 to the ventilation flap together with the supplied nuts • Positioning of the ventilation flap including mounting angle 1 in front of the opening and screwmounting in the shaft slab • Positioning of mounting angle 2 on the ventilation flap and screwmounting in the shaft wall

1

2

18

2


MODERNISATION

Horizontal

JK-190 Slab/Corner Drawings and dimensions with mounting angles

Section B-B

Section A-A

1

2

2

Corner view / shaft headroom

1

2

19


20

FURTHER INFORMATION

INTELLIGENT LIFT SHAFT SYSTEMS

w w w. bluekit .eu

EUROPE-WIDE AVAILABLE


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.