Highest Average or Highest Single Test Result
Contaminant (Date, if sampled in previous year)
EPA’s Ideal Goal (MCLG)
Nitrate
10 ppm
10.4 ppm
0.16 ppm
Aresenic
0 ppb
10.4 ppb
1,2-Dichloroethane
0 ppb
Gross Alpha Combined Radium
EPA’s Limit (MCL)
Range of Detected Test Results
Violation
Typical Sources
0.00 - 0.16 ppm
NO
Runoff from fertilizer use; Leaching from septic tanks, sewage; Erosion of natural deposits.
4.66 ppb
N/A
NO
Erosion of natural deposits; Runoff from orchards; Runoff from glass and electronics production wastes.
5 ppb
0.29 ppb
N/A
NO
Discharge from chemical agricultural chemical factories.
0 pCi/l
15.4 pCi/l
8.9 pCi/l
0.0 - 8.9 pCi/l
NO
Erosion of natural deposits.
0 pCi/l
5.4 pCi/l
4.7 pCi/l
0.0 - 4.7 pCi/l
NO
Erosion of natural deposits.