1 minute read
Service Maintenance
Slacken off nut (4). Turn out spring guide tube (2) by 3 revolutions. Turn nut (4) until spacer sleeve (3) makes contact at position (A) without pressure. Jam nut (4) and cylinder barrel (2).
At (X) no more than 3mm.
The Chaff Screen Cleaner should be checked regularly to ensure no external debris has blocked the suction fan unit. The cleaner will regulate itself during threshing engagement.
7 7
Gauge Rod Type Coolant Tank
When checking the level make sure the correct pre condition are followed see Operator manual, 9 Maintenance, 9.8 Hydraulic system, checking the hydraulic oil tank level. The correct hydraulic oil level is between the maximum mark (A) and the minimum mark (B).
Let the diesel engine and the coolant cool down. The expansion tank is sufficiently filled when the cooling liquid reaches up to the bottom edge of the filler neck. Sight glass (2) on the expansion tank is now completely filled.