Evaporadoras Hidronicas Clima Flex

Page 1

Evaporadoras Hidrónicas Rev. 2015-06-04

Rev. 2014-09-05

Clima-Flex, S.A. de C.V. Av. Central # 285 Parque Logístico - Delegación La Pila C.P. 78422, San Luis Potosí, México Tel. 52 (444) 161-5043 /ClimaFlexMexico @ClimaflexMexico www.clima-flex.com

www.clima-flex.com


Contents

01

▲03 Product Line Up

▲22 Controllers

▲04 Features and specifications

▲24 Accessories

▲14 Dimensions

▲25 Application of network & BMS control

▲19 Fan performance

▲26 Selection software

2


Product Line Up 2-pipe Fan Coil Units Cassette (300–1500CFM)

4-way Cassette

Duct (200-2200CFM)

Compact 4-way cassette

1-way Cassette

Wall-mounted (250-600CFM)

Features and specifications Four Rows Duct Tpye

Wall-mounted

*Meaning of the code Type Code

3

Meanings

A

4-way cassette

C

1-way cassette

D

Compact 4-way cassette

G

Wall-mounted

T4

4-row duct

04


2-Pipe 4-Way Cassette

4-way cassette

Model MKA-

2-Pipe 4-way cassette

600R

750R

850R

950R

1200R

1500R

600RA

750RA

850RA

950RA

1200RA

1500RA

2-Pipe compact 4-way cassette H/M/L

m³/h

1000/850/720

1250/1060/900

1400/1190/1010 1600/1360/1150 2000/1700/1440 2550/2170/1840

H/M/L

CFM

590/500/420

740/620/530

820/700/590

940/800/680

1180/1000/850

1500/1280/1080

H/M/L

kW

5.7/4.73/3.96

7/5.62/4.72

7.27/6.46/5.71

8.22/7.39/6.54

10.39/9.25/8.2

12.9/11.51/10.21

Water flow rate

H

l/h

980

1204

1250

1414

1787

2219

Water pressure drop

H

kPa

23.8

25.2

27

31.2

44

40

H/M/L

kW

9.66/7.72/6.27

11.55/9.24/7.51

12.42/9.93/8.07

H

kPa

16.4

11.8

14.6

Air flow

Capacity Cooling

Capacity

13.85/11.08/9 17.58/14.06/11.42 17.6/14.08/11.44

Heating Water pressure drop

Features

Power supply

V/ph/Hz

Power input

Capacity range: 300CFM to 1500CFM, available in 2-pipe.

H

Units with PCB.

Electric heater capacity (A)

4-way air supply panel is standard for 4-way cassette,360°air supply panel is standard

Sound pressure level

for compact 4-way cassette.

H/M/L

14.8

34.7

36.7

220-240/1/60

W

125

130

150

155

190

190

W

2100

2100

2850

2850

2850

2850

dB(A)

45/41/36

46/42/37

47/43/38

48/44/39

49/45/40

50/46/41

2

2

3

Low noise 4-speed fan motor

Type Fan motor

Unique design of the centrifugal fan ensures extra-quiet operation and high efficiency.

Quantity

Wireless remote control with LED display is standard, wired control is optional.

1 Centrifugal, forward-curved Blades

Type

Safety grill for safety maintenance.

Fan

Built-in drain pump with high pumping head.

Quantity

Optional extended drainage pan for protecting your ceiling better.

Row

Four-speed motor with one reserved for more choice.

Coil

1 2

2

2

Max. Working pressure

MPa

1.6

Diameter

mm

Φ7

Fresh air supply makes life healthier and more comfortable.

4-way panel

Fresh air supply

High water pump head

Dimensions

W×H×D

mm

950×45×950

Packing

W×H×D

mm

1035×90×1035

Net weight

kg

6

Gross weight

kg

9

Panel 750mm for 4-way cassette 500mm for compact 4-way cassette

Fresh air 360°panel

Quiet operation,soft air supply

Dimensions

W×H×D

mm

840×230×840

840×230×840

840×300×840

840×300×840

840×300×840

840×300×840

Packing

W×H×D

mm

900×260×900

900×260×900

900×330×900

900×330×900

900×330×900

900×330×900

Net weight

*/A

kg

25/27

25/27

30.5/33

30.5/33

30.5/33

31.8/37.5

Gross weight

*/A

kg

30/32

30/32

36.2/39

36.2/39

36.2/39

36/43.8

Body

Safety grill Water inlet/outlet pipe

Inch

RC3/4

Drain pipe

mm

ODΦ32

Pipe connection

Note: 1. H: high fan speed; M: medium fan speed; L: low fan speed. 2. Cooling conditions: entering water 7℃, temperature rise 5℃, entering air temperature 27℃DB/19℃WB. Heating conditions: entering water 50℃, entering air temperature 20℃DB, the same water flow as the cooling conditions. 3. The noise is tested in the semi-anechoic test room. 4. * for models without electric heater, A for models with electric heater.

05

06


2-Pipe Compact 4-Way Cassette

1-way cassette

Model MKD-

300

400

500

H/M/L

m³/h

510/440/360

680/580/480

850/730/600

H/M/L

CFM

300/260/210

400/340/280

500/430/350

H/M/L

kW

3/2.58/2.16

3.7/3.18/2.66

4.5/3.6/3.06

Water flow rate

H

l/h

516

636

774

Water pressure drop

H

kPa

14

15

16

H/M/L

kW

4/3.5/3.08

5.1/4.3/3.83

6/4.76/4.07

H

kPa

12

13

15

Air flow

Capacity Cooling

Capacity Heating Water pressure drop

V/ph/Hz

Power supply Power input Sound pressure level

220-240/1/60

H

W

50

70

95

H/M/L

dB(A)

36/33/28

42/39/32

45/42/34

Low noise 4-speed fan motor

Type Fan motor Quantity

1 Centrifugal, forward-curved Blades

Type Fan

Coil

Quantity

1

Row

2

Max. Working pressure

MPa

1.6

Diameter

mm

Φ7

Dimensions

W×H×D

mm

647×50×647

Packing

W×H×D

mm

715×123×715

Net weight

kg

2.5

Gross weight

kg

4.5

Features Capacity range: 300CFM to 600CFM. Smoother air flow with less turbulence. One direction air flow guarantees quick cooling, flexible installation position.

Panel

Space saving, only 153mm in height.

Dimensions

W×H×D

mm

575×261×575

Built-in drain pump with 750mm pumping head.

Packing

W×H×D

mm

670×290×670

Four-speed motor with one reserved for more choice.

Net weight

kg

16.5

Gross weight

kg

20

Water inlet/outlet pipe

Inch

G3/4

Drain pipe

mm

ODΦ25

Body

Space saving

One direction air flow

High water pump head

Single direction airflow,flexibly installed in various corners

Pipe connection

750mm

153mm UItra Thin

Note: 1. H: high fan speed; M: medium fan speed; L: low fan speed. 2. Cooling conditions: entering water 7℃, temperature rise 5℃, entering air temperature 27℃DB/19℃WB. Heating conditions: entering water 50℃, entering air temperature 20℃DB, the same water flow as the cooling conditions. 3. The noise is tested in the semi-anechoic test room.

07

08


09

10


4-Row Duct Model MKT4-

200G30

Air flow

Cooling

200/150/100 300/225/150 400/300/200 500/375/250

H/M/L

kW

H

l/h kPa

H/M/L

Water pressure drop

H

kW kPa

30

30

30

2.5/2.16/1.87 3.3/2.85/2.47 4.4/3.72/3.22 4.8/4.18/3.64 568

757

826

1066

1514

1634

2.6

5

8.1

9.8

15.4

12.3

18

2.2

4.2

6.9

8.1

12.7

10

15.4

220-240/1/60 50

65

80

98

110

155

180

38/34/28

38/35/29

40/35/30

41/36/31

42/37/32

44/39/33

1

1

1

2

2

4

4

Type

Low noise 4-speed fan motor

Type

1

1

Centrifugal, forward-curved Blades 1

Quantity

2

2

2

2 4

Max. Working pressure

MPa

1.6

Diameter

mm

Φ 9.52

Features

Dimensions

W×H×D

mm

741×241×522841×241×522941×241×522941×241×522 1161×241×522 1461×241×522 1566×241×522

Packing

W×H×D

mm

790×260×550890×260×550990×260×550990×260×550 1210×260×550 1510×260×550 1615×260×550

Net weight

kg

15.3

17.5

20.7

20.7

23.5

32.9

35.4

kg

17.6

20

23.1

23.1

26.5

36.5

39.1

Water inlet/outlet pipe

Inch

RC3/4

Drain pipe

mm

OD Φ24

Capacity

1200G30

1400G30

1500

1500G50

2000

2000G50

Cross flow fan creates quiet and comfortable environment.

Multi-connection outlet pipe method: left\right\rear, satisfy the need of different rooms.

H/M/L

m³/h

2040/1530/1020 2380/1785/1190 2550/2100/1300 2550/2100/1300

3400/2550/1700 3400/2550/1700

Built-in the 3-way electromagnetic valve.

H/M/L

CFM

1200/900/600 1400/1050/700

2000/1500/1000 2000/1500/1000

Easy maintenance has been realized as the front panel can be removed for easy access.

Pa H/M/L

kW

30

30

11.8/9.82/8.74 13/11.23/9.83

1500/1240/760

1500/1240/760

30

50

30

50

13.5/11.5/10.1

13.5/11.5/10.1

18/15.3/13.5

18/15.3/13.5 3096

H

l/h

2030

2236

2322

2322

3096

Water pressure drop

H

kPa

21.2

24.7

11.5

11.5

26.2

26.2

H/M/L

kW

17.5/14.9/13.2

17.5/14.9/13.2

23.4/19.8/17.5

23.4/19.8/17.5

H

kPa

10

10

24.3

24.3

Water pressure drop

16.5/14.05/12.23 17/14.31/12.69 17.6

20.8

V/ph/Hz

Power supply Power input Sound pressure level

Alternative panel supplies more choice for customs.

Wireless remote controller with LED display is standard, wired controller is optional.

Water flow rate

Capacity

S type panel

4.1/3.51/3.03 5.8/5.05/4.35 7.1/6.11/5.33 8.5/7.04/6.28 10.5/9.03/7.77 14.5/12.38/10.88 16.3/13.45/12.05

37/33/27

External Static pressure

Fan motor

9.5/8.18/7.06

W

Air flow

Heating

8.8/7.43/6.57

dB(A)

Model MKT4(H)-

Cooling

30

6.2/5.38/4.65

Wall-mounted

1000/750/500

H

Gross weight Pipe connection

30

430

Row

Body

800/600/400

30

H/M/L

Quantity

Coil

600/450/300

30

V/ph/Hz

Power input

Fan

1000G30

CFM

Power supply

Fan motor

800G30

H/M/L

Water flow rate

Sound pressure level

600G30

340/255/170 510/385/255 680/510/340 850/640/425 1020/765/510 1360/1020/680 1700/1275/850

Water pressure drop Heating

500G30

m³/h Pa

Capacity

400G30

H/M/L

External Static pressure Capacity

300G30

Four-speed motor with one reserved for more choice.

Easy maintenance

Multi-connection outlet pipe

220-240/1/60

H

W

220

275

236

474

360

665

H/M/L

dB(A)

45/40/34

47/42/36

48/44/39

51/47/42

50/46/41

53/49/44

1

1

2

3

3

Type

Low noise 4-speed fan motor 2

Quantity

2

1

Type

1

Centrifugal, forward-curved Blades

Fan Quantity

4

4

2

Row Coil

Max. Working pressure

MPa

1.6

Diameter

mm

Φ9.52

Dimensions

W×H×D

mm

1856×241×522 2022×241×522

1369×342×612

1369×342×612

1500×342×612

1500×342×612

Packing

W×H×D

mm

1905×260×550 2070×260×550

1421×381×619

1421×381×619

1552×381×619

1552×381×619

46

57

53.7

50

61

58.6

Body

Pipe connection

4

Net weight

kg

40.5

44.1

46

Gross weight

kg

44

49.4

49.8

Water inlet/outlet pipe

Inch

RC3/4

Drain pipe

mm

ODΦ24

Note: 1. H: high fan speed; M: medium fan speed; L: low fan speed. 2. The data is the performance in relevant external static pressure. 3. Cooling conditions: entering water 7℃, temperature rise 5℃, entering air temperature 27℃DB/19℃WB. Heating conditions: entering water 50℃, entering air temperature 20℃DB, the same water flow as the cooling conditions. 4. The noise is tested in the semi-anechoic test room.

11

12


S Type Panel Wall-mounted Model MKG-

250-B

300-B

400-B

500-B

600-B

H/M/L

m³/h

425/390/350

510/470/390

680/550/460

850/745/620

1020/915/780

H/M/L

CFM

250/230/205

300/275/230

400/325/270

500/440/365

600/540/460

H/M/L

kW

2.63/2.41/2.16

2.97/2.47/2.12

3.28/2.83/2.41

4.25/3.85/3.32

5/4.47/3.97

Water flow rate

H

l/h

452

511

564

731

860

Water pressure drop

H

kPa

29.4

35.6

43.5

31.8

42.5

H/M/L

kW

3.36/3.1/2.79

3.91/3.26/2.77

4.37/3.73/3.17

5.81/5.17/4.43

6.7/6/5.28

H

kPa

27.3

32.9

40.8

30.2

39.7

Air flow

Capacity Cooling

Capacity Heating Water pressure drop

V/ph/Hz

Power supply Power input Sound pressure level

220-240/1/60

H

W

24

37

40

50

66

H/M/L

dB(A)

30/24/20

35/29/24

37/31/26

39/33/28

40/34/29

Dimensions

Low noise 4-speed fan motor

Type Fan motor Quantity

1

Type

Tangential fan

Fan

Coil

Quantity

1

Row

2

Max. Working pressure

MPa

1.6

Diameter

mm

Φ7

Dimensions

W×H×D

mm

915×230×290

915×230×290

915×230×290

1072×230×315

1072×230×315

Packing

W×H×D

mm

1020×315×390

1020×315×390

1020×315×390

1180×315×415

1180×315×415

Net weight

kg

13

13

13.3

15.8

15.8

Gross weight

kg

16.3

16.3

16.7

19.4

19.4

Body

Water inlet/outlet pipe

Inch

G3/4

Drain pipe

mm

ODΦ20

Pipe connection

Note: 1. H: high fan speed; M: medium fan speed; L: low fan speed. 2. Cooling conditions: entering water 7℃, temperature rise 5℃, entering air temperature 27℃DB/19℃WB. Heating conditions: entering water 50℃, entering air temperature 20℃DB, the same water flow as the cooling conditions. 3. The noise is tested in the semi-anechoic test room.

13

14


Dimensions 4-way cassette

Compact 4-way cassette

2-pipe 4-way cassette

2-pipe compact 4-way cassette

Dimensions (unit:mm)

Dimensions (unit:mm)

MKA-600R(A) MKA-750R(A) MKA-950R(A) MKA-1200R(A) MAK-1500R(A)

A

B

C

D

230

170

135

185

300

190

145

195

124

213

190

647 (Panel)

C

D

A

B Size Model

261

Tubing side

950(Panel)

840(Body)

680(Hook-location)

Drain side

575 (Body)

Drain side

523 (Hook-location)

Tubing side

545 (Hook-location)

780(Hook-location) 575 (Body) 840(Body) 647 (Panel) 950(Panel)

Service Spaces (unit:mm)

Service Spaces (unit:mm)

Water pipe joint

Drain pipe joint

Drain pipe joint

Inlet

Outlet

Ground

>1000

Outlet

Inlet

Outlet

Panel

600 (ceiling hole)

Ground

2-pipe 4-way cassette

15

Panel

880 (ceiling hole) >1000

>1000

Outlet

2300~2800

Ceiling ďźž2500

> 10 0 0

Ceiling

>300

>1000

330

>1000 C

>1000

>1000

Water pipe joint

2-pipe compact 4-way cassette

16


Height of the front panel

Four rows duct type Dimensions (unit:mm)

1 -way cassette Dimensions (unit:mm)

169

MKC-300R(A)-B MKC-400R(A)-B

1054

290 425

1015

Condensation water outlet ZG3/4”

Terminal board 335

Dimensions (unit:mm) 0

Water inlet RC3/4” 612

MKG (S panel)

342

A B

Air filter

0

Water outlet RC3/4”

C

D

40

58

0

0

160

145

195

Air release valve

4-10x16 Long orifice for suspended removement

231 230

19

10

340

E

1500CFM series

1085

1135

1112

1085

1369

2000CFM series

1277

1327

1308

1277

1500

Note: The above figure is only an instance, which would be different from the one that you purchase. The dotted line in the figure is the dimension for air return plenum. Units with air return plenum is standard, units without air return plenum can be customized.

17

18


Fan performance MKT4-200~1400G30 MKT4-300G30

70

60

50

MKT4-400G30

90

Static pressure, Pa

80

Static pressure, Pa

Static pressure, Pa

MKT4-200G30

80 70 60

100 90 80 70 60

50 40

50 40 40

30 30

30 20

20

10

20

10

0 200

④ 250

300

350

400

10

0

450

500

200

300

400

Air flow, m³/h

500

600

700

80

MKT4-800G30

120

Static pressure, Pa

Static pressure, Pa

100

200 300 400 500 600 700 800 900

Air flow, m³/h

MKT4-600G30

120

0 800

Air flow, m³/h

MKT4-500G30 Static pressure, Pa

100

80

140

120

100

80 60

60 60

40

40 40

20

20

20

0 550

700

850

1000

1150

0 400

Air flow, m³/h

600

800

1000

1200

1400

400

700

Air flow, m³/h

MKT4-1000G30

MKT4-1200G30 Static pressure, Pa

140

120

100

③ 1000

② 1300

① 1600

1900

Air flow, m³/h MKT4-1400G30

160

Static pressure, Pa

400

Static pressure, Pa

0

140

120

100

160

140

120

100

80 80

80

60

60

40

40

60

40

20

20

1000

1400

0

0 600

Air flow, m³/h

19

20

1800

2200

600

1000

③ 1400

1800

Air flow, m³/h

② 2200

0 2600

600

1000 1400 1800 2200 2600 3000 Air flow, m³/h

20


MKT4H-1500G50 P(Pa)

For cassette and wall-mounted type FCU

100

80

HIgh Speed Medium Speed

60

Low Speed 40

20

800

1200

1600

2000

2400

2800

3200 Q(m続/h)

P(Pa)

MKT4H-2000G50

100

80

HIgh Speed Medium Speed

60

CCM03/CCM30. 40 CCM30 is a centralized controller with touch-style keys. CCM30 has air filter cleaning reminding function.

Low Speed 20

CCM03/CCM30.

CCM30 800

21

1400

2000

2600

3200

3800

4400 Q(m続/h)

22


For Duct type FCU

★Fan speed selection:high/medium/low/Automatic. ★Timer for on/off of units. ★Clock display.

KJRP-86A1-E

★Working Environment: Temperature:5~45℃ Relative Humidity: <92 %. ★External Dimension:85×85×15 m m( W × H × D). ★Installation method:86 box installationtion(standard). Note: The item with“★”are available for KJRP-86A1-E.

KJRP-86A1-e

23

24


Application of Central Control Software & BMS Control Indoor CCM03/CCM30

Indoor CCM03/CCM30

PC Access

LAN

CCM30 Laptop Access

M-interface

The new indoor unit central controller has a touch-style key. The big screen and LCD display can give you a more comfortable visual effect. All basic function as the same as CCM03.

M-net

Pad Access

Router

4th Generation Monitoring System

4th Generation Monitoring System Consists of three parts: the IMM PC software and M - interface gateway. Up to maximum of 4 M-interfaces, 64 refrigerant systems, 1024 indoor units,and 256 outdoor units can be controlled by one PC. Web Access. No geographical restrictions for PC based IMM software. Data converter CCM15

Data Converter CCM15 BMS

BACnet/Modbus/LonWorks

Can realize data conversion between TCP/IP protocol and 485 protocol. Can remotely control the A/C systems through computer, iPhone, iPad or other intelligent terminals. Providing the TCP / IP port for A/C system of Midea to achieve WEB/HTTP/TCP/IP access. User can monitor and query A/C equipment through LAN and WAN.

BACnet Gateway-CCM08 25

BACnet/Ethernet optional. No need to install the Network Control Software any more. By inputting IP address of CCM08, PC in LAN could access CCM08 to realize simple setting and controlling of A/C.

26


Selection interface

Report data interface


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.