CLIM-WCC-120-N3V-M-E

Page 1

Rev. 2014-12-17

CLIM SERIES CLIM-WCH-120-N3V-M HEAT PUMP

Mini Chiller Water Cooled MASTER UNIT

SELECTION CONDITIONS Elevation over sea level (ft) Condensing water temperature (°F) Leaving water temperature (°F)

0.0 85 44

COOLING MODE Nominal Capacity (BTU/hr) Rated Capacity (BTU/hr) EER (BTU/W*h) IPLV (EER) COPR

120,000 134,817 15.59 21.44 4.57

HEATING MODE Heating Capacity (BTU/hr) Power Consumption (kW) COPH Leaving water temperature (°F)

156,483 9.08 5.05 110

ELECTRICAL DATA

COMPRESSOR Compressor Type Quantity Power Consumption (kW) Current Consumption (A)

Inverter Scroll 1 8.65 25.56

CONDENSER Type Water Flow (GPM) Inlet Water Temperature (°F) Outlet Water Temperature (°F)

Stainless Steel Plates 30 85 95

Power source (V,Φ,Hz) MOP (A) MCA (A) Total Current Consumption(A) Total Power Consumption (kW)

220 / 3 / 60 57.50 32.00 25.56 8.65

UNIT DATA Refrigerant Type Refrigerant Weight (lbs) Sound Level (Db) Net Weight (lbs) Operation Weight (lbs) Controller Total Water Evaporator Pressure Drop (ft WG) Total Water Condenser Pressure Drop (ft WG)

R410-A 7.00 68 642.00 686.00 Digital 12.94 14.71

DIMENSIONS EVAPORATOR Type Water Flow (GPM) Inlet Water Temperature (°F) Outlet Water Temperature (°F)

Stainless Steel Plates 24 54 44

Length (in) Width (in) Height (in) Inlet/Outlet water (in)

40.25 30.00 45.75 2 1/2

Standard Characteristics Limited Warranty for Clima-Flex units. • 1 year warranty for funcional equipment parts. • 2 years warranty for compressor. Notes 1. EER and IPLV mentioned in the tables above are applied with non-ducted indoor units. Values are based on AHRI Standar 550 / 590 and are subject to change without previous notice. Performance data can be found on the AHRI website http://ww.ahridirectory.org/ 2. All communication cable to be minimum 18 AGW, 3 conductor, stranded, shielded and must comply with applicable local and national code. 3. The rated data mentioned in this technical data is applied with non-ducted indoor units. 4. The voltage tolerance is ±10%. 5. Power wiring cable size must comply with the applicable local and national code. Cable THW at 75°C Cal. 6. 6. Efficiency data do not consider circulator water pump. 7. Installation and maintenance must be performaed by properly trained and qualified personnel equipped with the proper tools.

Clima-Flex, S.A. de C.V. Av. Central #285 Parque Industrial Logistico / Delegacion La Pila / San Luis Potosí, México / ZIP Code 78422 Phone +52 (444) 161-5043 Facebook/clima-flex @climaflexMexico www.clima-flex.com


CLIM SERIES CLIM-WCH-120-N3V-M HEAT PUMP

Mini Chiller Water Cooled

Clima-Flex, S.A. de C.V. Av. Central #285 Parque Industrial Logistico / Delegacion La Pila / San Luis Potosí, México / ZIP Code 78422 Phone +52 (444) 161-5043 Facebook/clima-flex @climaflexMexico www.clima-flex.com