CLIMWP-ACC-061-A3D-E

Page 1

Rev. 2014-12-17

CLIWP SERIES CLIWP-ACC-061-A3D COOLING ONLY

Packaged Unit CLIWP UNIT

SELECTION CONDICITIONS Elevation over sea level (ft) Ambient temperature (°F) Air leaving temperature (°F)

0.0 95 55 / 57

COOLING MODE Nominal Capacity (BTU/hr) Rated Capacity (BTU/hr) EER (BTU/W*hr) IPLV (EER) COPR

61,000 55,700 9.65 N/D 2.83

HEATING MODE Heating Capacity (BTU/hr) Power Consumption (kW) COPH Air leaving temperature (°F)

N/A N/A N/A N/A

ELECTRICAL DATA

COMPRESSOR Compressor Type Quantity Power Consumption (kW) Current Consumption (A)

Digital Scroll 1 4.65 14.40

CONDENSER FAN Type Air Pressure Drop (inH2O) Air Operating Range (°F) Power Consumption (kW) Current Consumption (A)

Axial 0.40 95.0 0.56 5.70

EVAPORATOR FAN Type Air Pressure Drop (inH2O) Air Operating Range (°F) Power Consumption (kW) Current Consumption (A)

Centrifugal 1.00 67.5 0.56 3.20

CONDENSER Type Air Flow (CFM) Area (ft2) Air Pressure Drop (inH2O)

Microchannel 4,000 8.75 0.40

EVAPORATOR Type Air Flow (CFM) Area (ft2) Air Pressure Drop (inH2O)

Cu-Al 2,000 3.56 0.50

Power Source (V,Φ,Hz) MOP (A) MCA (A) Total Current Consumption (A) Total Power Consumption (kW)

220 / 3 / 60 41.30 29.20 23.30 5.77

UNIT DATA Refrigerant Type Refrigerant Weight (lbs) Sound Level (Db) Net Weight (lbs) Controller

R410-A 5.00 68 430.00 Digital

DIMENSIONS Length (in) Width (in) Height (in)

41.00 21.50 83.00

Standard Characteristics Limited Warranty for Clima-Flex units. • 1 year warranty for funcional equipment parts. • 2 years warranty for compressor. Notes 1. EER and IPLV mentioned in the tables above are applied with non-ducted indoor units. Values are based on AHRI Standar 310 / 380 and are subject to change without previous notice. Performance data can be found on the AHRI website http://ww.ahridirectory.org/ 2. All communication cable to be minimum 18 AGW, 3 conductor, stranded, shielded and must comply with applicable local and national code. 3. The rated data mentioned in this technical data is applied with non-ducted indoor units. 4. Values include elevation over sea level correction factor. 5. The voltage tolerance is ±10%. 6. Power wiring cable size must comply with the applicable local and national code. Cable THW at 75°C Cal. 6. 7. Installation and maintenance must be performaed by properly trained and qualified personnel equipped with the proper tools.

Clima-Flex, S.A. de C.V. Av. Central #285 Parque Industrial Logistico / Delegacion La Pila / San Luis Potosí, México / ZIP Code 78422 Phone +52 (444) 161-5043 Facebook/clima-flex @climaflexMexico www.clima-flex.com


CLIWP SERIES CLIWP-ACC-061-A3D COOLING ONLY

Packaged Unit

Clima-Flex, S.A. de C.V. Av. Central #285 Parque Industrial Logistico / Delegacion La Pila / San Luis Potosí, México / ZIP Code 78422 Phone +52 (444) 161-5043 Facebook/clima-flex @climaflexMexico www.clima-flex.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.