We are leaders in the creation of innovative air conditioning solutions using state of the art technology and world class product design
CONTENTS
USER MANUAL
1
CONTENTS
1
NOMENCLATURE
2
FEATURES / BENEFITS
3
CONSTRUCTION FEATURES
5
COILS, PHYSICAL DATA
8
PHYSICAL DATA
19
FAN INFORMATION DATA
20
THERMOSTAT PACKAGES
23
DIMENSIONAL DATA
25
Notes: Some drawings not shown All data herein is suject to change without notice Drawings not for installation purposes
TYPE
SERIE
V
Vertical
0 115-127v/1/60Hz
D
Ductable
2 208-230v/1/60Hz
HYDRAULIC CONNECTION
COOLING ROWS
3
3 Rows
D
Dual
4
4 Rows
R
Right
6
6 Rows
L
Left
N
None
D 400 2 3 1 R C E P NOMINAL CAPACITY Standard
400 600 800
High Static
HEATING ROWS
400 CFM
1200 1200 CFM
0
No Rows
600 CFM
1600 1600 CFM
1
1 Rows
2
2 Rows
800 CFM
1000 1000 CFM 1300 1300 CFM
2000 2000 CFM
FAN TYPE
C
3 Speed
F
EC Fan
D 1
C
ADSIL for Condenser
0
None
6 6 Kw
1 1 Kw
7 7 Kw
2 2 Kw
8 8 Kw
3 3 Kw
9 9 Kw
4 4 Kw
10 10 Kw
5 5 Kw
N None
PLENUM
CORROSION PROTECTION
+ Internal E ADSIL+Condenser External Parts ADSIL Condenser + I Internal Parts
ELECTRIC HEAT
FILTER TYPE
P
Plenum
D
Disposable
N
No plenum
W
Washable
S
Special
NOMENCLATURE
CLIFC
VOLTAGE
2
• HIGH PERFORMANCE
The Comfort Flex Vertical Fan & Coil is designed to maximize flexibility of selection and installation, and for ease of service. The units are designed to exceed the stringent quality standards of the institutional market, while remaining cost competitive in the commercial and residential segments of the market.
FEATURES / BENEFITS
Comfort Flex Vertical Fan & Coil units set the new standards for innovation, quality, flexibility, and competitive pricing
3
• DESIGN FLEXIBILITY
The extensive variety of standard options available on Comfort Flex Vertical Fan & Coil units are where you find the versatility to fit any HVAC system designer’s needs. Options Include: • Single wall stainless steel drain pans • Foil faced or elastomeric closed cell foam insulation • Motorized 2 & 3 way valves • Electric heat with single point power connection • AC & EC fans • Decorated panels available in different colors (optional) A total of four rows of coil are accommodated.
• CONVENIENT INSTALLATION
All Comfort Flex Vertical Fan & Coil are shipped completely assembled, reducing field installation time and labor. All units are thoroughly inspected and tested prior to shipment, eliminating potential problems at startup. Motor wiring is brought to a control compartment on the inside of the unit, reducing electrical hook-up time. Factory furnished pressure tested valve packages; assure proper fit, operation and performance. Comfort Flex Vertical Fan & Coil have several standard features that provide for installation flexibility that are unmatched in the industry. Supply air opening knockouts are included on all sides and on the top of the unit.
• OPTIMUM BUILDING PERFORMANCE
The Comfort Flex Vertical Fan & Coil fan coil chassis is built from galvanized steel 18 gage. This metal surpasses the ASTM 125 hour salt spray test for corrosion and rust. Standard insulation is 1/2 inch thick fiberglass, complying with UL 181 and NFPA 90A. Optional foil faced or elastomeric closed cell foam insulation may be specified. All wiring is in compliance with NEC & UL standards, ensuring safety and quality for the owner and the installer. Comfort Flex Vertical Fan & Coil are removable. The entire coil assembly can be easily removed from the unit and replaced or serviced on a workbench, reducing equipment down time. Coils are accessible for cleaning and removable for service or replacement. Filters are easily replaceable when the decorator front panel is removed. As an option, the drain pan can be equipped for removal for cleaning or replacement without disturbing the coil assembly.
ESTRUCTURE
GRID
FILTER
ELECTRIC CONTROL
FEATURES / BENEFITS
BLOWER
COIL
4
Powder coated 18 gauge steel decorator front panel return grille (not shown)
CONSTRUCTION FEATURES
Optional electric heat is ETL listed as an assembly for safety compliance
5
Optional blower shield (not shown) eliminates accidental contact with fan assembly Side and back panels are manufactured with knockouts for piping and supply air openings. Facilitates field conversion of supply air grille locations
Exposed cabinet features durable, powder coat paint
Top discharge knockout permits ducted connection
Hinged, quick open control door allows easy access to all electrical components
Permanently lubricated, three tap, PSC fan motors designed for quiet and efficient operation
Unit or wall mounted analog, digital display, or programmable thermostats
Factory mounted piping packages 1 Coil heating located in the reheat position Maximum 4 total rows of coils combined
Fan assembly can be easily removed for servicing on slide out rails
Single point power connection on all units with and without electric heat
Up to 4 rows of chilled water cooling coils Double deflection discharge grille (optional)
The entire electric heat assembly can be removed
Optional removable drain pan
Double wall composite or stainless steel (optional) insulated drain pans are double sloped to drain connections
Integral ¾” throw away filter (standard), or ¾” pleated or synthetic media filter (optional)
1/2” thick fiberglass insulation (standard) or foil faced or elastomeric closed cell foam insulation (optional)
Comfort Flex Vertical Fan & Coil have many standard and optional features which are unique to the industry.
• FAN DECK
• DRAIN PAN
Filter options include 1” throwaway (standard), pleated MERV 8, or synthetic media. Filters are easily replace- able from the return air when the front panel is removed.
The sloped insulated drain pan is available in stainless steel construction. Standard drain pans are galvanized, composite, extend under the entire coil section, double sloped, and are removable. As an option, the Comfort Flex Vertical Fan & Coil drain pan can be equipped for easy removal from the front of the unit for inspection and cleaning. For optimum moisture resistance and cleanability, the fan coil unit may be lined with foil faced fiberglass insulation (shown below) or elastomeric closed cell foam insulation.
• POWDER COAT PAINTED SURFACE Exposed cabinet as well as the front return textured decorator panel, feature a powder coat finish that resists scuffing, scratching, fading, and fingerprints.
• COIL & PIPING All fan coils are available in 2 or 4 pipe configurations. The heating coil is standard in the reheat position. Access for cleaning on both the entering and leaving air sides is available. Coils are removable from the front of the unit for service.
• STAINLESS STEEL BRAIDED HOSES Stainless steel braided hoses allow for flexibility and thermal expansion within the unit cabinet. The hose-to-coil and hose-to-riser connections are made via a threaded swivel adapter, simplifying coil removal.
• CONTROL ENCLOSURE The spacious hinged electrical compartment houses all electric heat and control components. Terminal strips are furnished for simple power and control wiring connections.
CONSTRUCTION FEATURES
For ease of service, the fan/motor assembly is easily removed by unscrewing two locknuts located at the front of the assembly. Slide rails support the fan during removal and installation, and the electrical harness is equipped with a quick connect plug.
• FILTERS
6
CONSTRUCTION FEATURES
REDUCING MOLD GROWTH IN HI RISE DEEP LOADING, SYNTHETIC MEDIA RESIDENTIAL PROJECTS FILTRATION
7
Comfort Flex Vertical Fan & Coil feature several options to mitigate mold and mildew when applied in a properly designed and constructed building. For humid climates, Comfort Flex offers innovations to ensure optimum humidity control at part load conditions. The Clima-Flex units are pioneer in the VRW technology. The most important advantage is the modulation of the 2 way chilled water valve together with the EC motor fan to maintain the proper flow while maintaining the chilled water temperature through the coil at minimum CFMs required to have a continuous dehumidification needed.
The inorganic film on the surface is ultra thin and is formed by an inert ceramic glass layer that is obtained at ambient temperatures. This innovative technology provides:
(OPTIONAL)
• UV resistance • A crystalline finished, non-yellowing • Positively charged coating to repel H2O • Magnificent luster and depth of image retention • Outstanding resistance to solvents and chemicals • Exceptional abrasion resistance
• ENERGY EFFICIENT
With ADSIL you save energy between 9% to 15%. Its sealant layer of only 3-5 microns allows heat transfer be more efficient.
• EXTENDS THE LIFE OF THE EQUIPMENT
ADSIL extends the life of your air conditioner units, refrigerators or cooling towers, because it protects up to 5 years, preserving its appearance and function. ADSIL is applied to cabinets, capacitors, grids and coils, achieving great benefits and durability that can not be obtained with conventional protections.
Protects both the coil and the coil bypass air from airborne contaminants. Filter frame and media are non-organic, and will not support mold growth.
INNOVATIVE TEMPERATURE AND HUMIDITY CONTROLLER (MODBUS ENABLE) Improves part load relative humidity control.
STAINLESS STEEL DRAIN PANS AND COIL CASINGS
Are available for use where added corrosion resistance or longevity are required. Coils and piping packages are removable in minutes through the standard front panel with only a screwdriver and pair of wrenches for periodic cleaning or service outside of the unit.
ELASTOMERIC CLOSED CELL FOAM INSULATION Is a great alternative to fiberglass insulation in extremely humid climates, as
well as hirise residential facilities. The material’s smooth and cleanable surface makes it naturally mold resistant, with no danger of fibrous material entering the airstream. Additional features include: • Easily cleaned surface resists dirt, moisture absorption, and microbial growth – even if torn or punctured. • Higher temperature limit than polyethylene CCF, able to withstand service temperature spikes without permanent failure. • More flexible than polyethylene CCF at 75°F, allowing expansion and contraction in hot and cold cycle applications. • Compression resistance; retains its thermal insulating capacity. • Outer moisture vapor barrier or liner not required.
IAQ DRAIN PAN
Is double sloped to prevent standing water. An optional drain pan is removable for effective cleaning.
BLOWER ESTRUCTURE
FILTER
ELECTRIC CONTROL
COIL
COILS, PHYSICAL DATA
GRID
8
STANDARD FEATURES • CONSTRUCTION
• DRAIN PANS
• Galvanized steel construction 18 Gage
• Double wall, composite, anti-microbial
• 1/2” thick fiberglass insulation
• Double sloped to drain connection
• Integral filter rack with ¾” throwaway filter
• Removable, extended under the entire coil section.
• Supply air knockouts
• 7/8” O.D. drain connection
• Stamped louver return air grille
• Centrifugal EC motor fans
• Durable powder coat paint
• 115 volt, single phase or 220/3/60
• Quarter-turn cam lock fasteners
• Quick disconnect motor connections
COILS, PHYSICAL DATA
• DECORATOR FRONT PANEL
9
• SUPPLY AIR • Single outlet
• Front, side or top outlets
• COILS
• Cooling - 3 or 4 row chilled water • 4 total rows of cooling and heating coils maximum • High efficiency aluminum fin surface for optimizing heat transfer, pressure drop
• FAN ASSEMBLIES
• Easily removable fan/motor deck for service
• ELECTRICAL
• UL listed construction materials for safety compliance • Electrical enclosure with access door for field wiring terminations • Terminal block for field connections
• ELECTRIC HEAT
and carryover
• Integral electric heat assembly with removable elements for easy service
• Easily removable for service
• Single point power connection
• Manual air vents
• ELECTRIC HEAT
• Integral electric heat assembly with removable elements for easy service • Single point power connection
• CONSTRUCTION
OPTIONAL FEATURES
• ELECTRICAL
• Foil faced fiberglass insulation
• Toggle disconnect switch
• Elastomeric closed cell foam insulation
• Main fusing
• ¾” pleated filter (MERV 8)
• Unit and remote mounted Thermostats
• Blower shield
• ELECTRIC HEAT • Silent relay/contactors
• Recessing frame
• Door interlocking disconnect switches
• Full faced aluminum grille
• Main fusing
• SUPPLY AIR
• PIPING PACKAGES
• Double outlets
• Factory assembled and installed
• Sight and sound baffles for double outlet units
• 1/2” 2-way
• Opposed blade damper Coils
• Adjustable flow control devices
• Stainless steel coil casings
• P/T ports and Y-strainers • Modulating control valves
• DRAIN PANS
• THERMOSTATS
• Removable for cleaning
• Digital display • Unit and wall mounted
• FAN ASSEMBLIES • 15, 208-230 & 277V, single phase EC motor
• Automatic and manual changeover
COILS, PHYSICAL DATA
• DECORATOR FRONT PANEL
10
COILS
• STANDARD RATINGS
Comfort Flex offers hot water and chilled water coils for specific application with all Comfort Flex Vertical Fan & Coil. Strict on-site inspection before, during, and after installation guarantees the highest quality and performance available. All coils are tested at 600psi to prevent any on site failure.
• ALTITUDE CORRECTION FACTORS
COILS, PHYSICAL DATA
ALTITUDE CORRECTION FACTORS
11
ALTITUDE (FT.)
0
1000
2000
3000
4000
5000
6000
7000
AIR DENSITY (LB/Ft3)
0.075
0.0722
0.0697
0.0672
0.0648
0.0625
0.0601
0.0579
TOTAL CAPACITY
1.000
0.988
0.986
0.983
0.981
0.979
0.977
0.975
SENSIBLE CAPACITY
1.000
0.960
0.930
0.900
0.860
0.830
0.800
0.770
STATIC PRESSURE
1.000
0.960
0.930
0.900
0.860
0.830
0.800
0.770
Note: Capacity and static pressures will be affected for applications above sea level. To apply correction factors, multiply factor to desired coil capacity or fan curve data. Example: F&C with 3 row coil, high speed fan operation at 3000 ft. above sea level and with 0.1 IN. W.C. ESP. Solution: Using correction factors from Altitude Correction chart for 3000 ft. above sea level, data from Standard Ratings table and fan curves. Total capacity = 12,500 BTUH (.983) = 12,288 BTUH Sensible Capacity = 8,000 BTUH (.90) = 7,200 BTUH SP = .1 (.90) = .09 IN. W.C.
• FACE, FREE AREA AND FILTER SIZE UNIT SIZE
COIL FACE AREA
FILTER FACE AREA
ACTUAL FILTER SIZES
4
2.48 [.19]
2.83 [.20]
17.75x23x1”
6
2.48 [.25]
2.83 [.27]
17.75x23x1”
COIL
MODEL / SIZE
Rows
FPI
AIRFLOW CFM (DRY FLOW)
FS 04
4
13
FS 06
4
13
COOLING CAPACITY
WATER
QT (BTUH)
QS (BTUH)
Flow Rate (GPM)
WPD Ft-Wg
POWER INPUT (WATTS)
ALTITUDE
450
13,700
10,000
2.4
15.0
118
6080 FT
620
22,400
15,600
3.6
17.0
142
6080 FT
• UNIT WEIGHT DATA COMPONENT
4
6
82
82
4 ROW - DRY (Kg)
16
16
4 ROW - WET (Kg)
18
18
BASE UNIT (Kg) TOTAL COILS ROWS
UNIT SIZE
NOTE: Unit weight data is in pounds [kilograms].
CliFCV Variable Series General description
Cooling only
Voltage (V-F-Hz)
127-1-60
Fan
1 ECM
Coil
CU-AL
Control
Wall thermostat
Coil connection (in)
5/8
Elevation over the sea (ft)
7,350
Ambient temperature
87.6
Weight
82
400
600
Coil fins X in2
13
13
Rows
4
4
Lenght (in)
14
14
COOLING ONLY MODEL
CFM GPM
ENTERING WATER TEMP 째F
LEAVING WATER TEMP. 째F
TOTAL CAP. (KBTU/HR)
SENSIBLE COIL LOAD CAP. (KBTU/HR)
ENTERING AIR TEMP. (DB/WB 째F)
LEAVING AIR TEMP. (SBS/SBH 째F)
WATER PRESSURE DROP (FT-H2O)
CLIFCV-ACC-400
400
2.4
45
55
10.58
8.44
75.0/59.7
54.6/53.0
25.3
CLIFCV-ACC-600
600
3.7
45
55
14.2
11.4
75.0/59.7
54.6/53.0
31.9
FAN - 25 MODEL
CFM
DB SUC.
I (A)
W (mm)
H (mm)
D (mm)
WEIGHT (Kg)
STATIC PRESSURE EXTERNAL (INH2O)
CLIFCV-ACC-400
400
62
0.30
252
252
125
8
0.150
CLIFCV-ACC-600
600
64
0.70
252
252
125
8
0.310
COILS, PHYSICAL DATA
Coil
12
COILS, PHYSICAL DATA 13
COOLING ONLY
COOLING ONLY
MODEL
A (in)
B (in)
C (in)
<#
DESCRIPTION
#
DESCRIPTION
CLIFCV-ACC-400
20 ¼
82 3/8
20
1
½” COVER
8
FILTER
CLIFCV-ACC-600
20 ¼
82 3/8
20
2
FAN
9
DRAIN HOSE
3
COIL
10
ELECTRIC ACCESS
4
TRAY
11
THERMOSTAT
5
DRAIN
12
MULTIPURPOSE ACCESS
6
INJECTION GRILL
13
INJECTION / RETURN PORTS
7
ACCESS GRILL
14
INJECTION
Filer Merv 5; efficiency over 20%. Disposable 1in. Average arrestance 80%; particles 3-10 μm.
MEASUREMENTS C1
C2
C3
C4
C5
C6
C7
C8
C9
CFM
AMP
DB
NC
1
0
0
0
0
0
0
0
0
0
0
0.2
31.0
20
2
158
153
158
153
156
158
144
0
0
195.6
0.2
33.3
25
3
257
293
256
248
287
277
249
0
0
338.2
0.2
40.3
30
3.5
311
326
291
259
350
330
315
0
0
395.3
0.3
44.2
35
4
368
404
384
390
395
364
337
0
0
478.6
0.3
51.0
40
5
494
529
450
495
512
488
455
77
212
523.0
0.5
53.0
45
6
594
627
539
596
606
567
533
0
164
595.4
0.7
57.9
50
7
693
717
644
716
702
697
675
0
177
707.4
1.0
61.1
55
8
789
844
725
795
813
800
748
0
157
799.0
1.5
63.4
55
9
897
940
797
879
795
928
928
116
120
901.7
2.2
66.5
60
10
985
1056
941
1032
979
1004
893
0
187
997.1
3.0
69.2
65
COILS, PHYSICAL DATA
VOLTAGE
14
CliFCV Variable Series General description
Cooling only
Voltage (V-F-Hz)
127-1-60
Fan
1 ECM
Coil
CU-AL
Control
Wall thermostat
Coil connection (in)
5/8
Elevation over the sea (ft)
7,350
COILS, PHYSICAL DATA
Ambient temperature
15
87.6
Weight
80
Coil
400
600
Coil fins X in2
13
13
Rows
4
4
Lenght (in)
14
14
COOLING ONLY MODEL
CFM GPM
ENTERING WATER TEMP 째F
LEAVING WATER TEMP. 째F
TOTAL CAP. (KBTU/HR)
SENSIBLE COIL LOAD CAP. (KBTU/HR)
ENTERING AIR TEMP. (DB/WB 째F)
LEAVING AIR TEMP. (SBS/SBH 째F)
WATER PRESSURE DROP (FT-H2O)
CLIFCV-ACC-400
400
2.4
45
55
10.58
8.43
75.0/59.7
54.6/53.0
25.3
CLIFCV-ACC-600
600
3.7
45
55
14.2
11.4
75.0/59.7
54.6/53.0
31.9
FAN - 28 MODEL
CFM
DB SUC.
I (A)
W (mm)
H (mm)
D (mm)
WEIGHT (Kg)
STATIC PRESSURE EXTERNAL (INH2O)
CLIFCV-ACC-400
400
54
0.32
292
292
196
6
0.153
CLIFCV-ACC-600
600
56
0.40
292
292
196
6
0.331
COOLING ONLY
<#
DESCRIPTION
#
DESCRIPTION
MODEL
A (in)
B (in)
C (in)
1
½” COVER
8
FILTER
CLIFCV-ACC-400
20 ¼
82 3/8
20
2
FAN
9
DRAIN HOSE
CLIFCV-ACC-600
20 ¼
82 3/8
20
3
COIL
10
ELECTRIC ACCESS
4
TRAY
11
THERMOSTAT
5
DRAIN
12
MULTIPURPOSE ACCESS
6
INJECTION GRILL
13
INJECTION / RETURN PORTS
7
ACCESS GRILL
14
INJECTION
Filer Merv 5; efficiency over 20%. Disposable 1in. Average arrestance 80%; particles 3-10 μm.
COILS, PHYSICAL DATA
COOLING ONLY
16
COILS, PHYSICAL DATA 17
MEASUREMENTS %
C1
C2
C3
C4
C5
C6
C7
C8
C9
CFM
AMP
DB
NC
3
350
408
380
370
360
380
370
370
200
372
0.2
40.4
30
3.5
420
480
450
443
445
380
466
430
240
439
0.3
50.8
40
4
440
521
530
520
460
400
375
510
270
470
0.4
51.5
40
5
560
685
654
650
610
550
474
678
350
607
0.4
53
45
5.5
627
750
724
700
670
580
637
736
420
680
0.6
57
50
DIAGRAM
COILS, PHYSICAL DATA 18
STANDARD FEATURES • STANDARD FEATURES • Single point power connection • Internal wiring rated at 105°C • Integral electric heat assembly with removable element for easy service • Stainless steel terminals and hardware
• ELECTRICAL CALCULATIONS INFORMATION • Contact your local Comfort Flex representative for more information on electrical calculations, including FLA,MCA, and MOP. • Non-Fused Door Interlock Disconnect Switch shall be sized according to MCA.
PHYSICAL DATA
• Main Fusing shall be sized according to MOP.
19
RH28V-6IK
• VPRO-ECBLUE
Caracteristic curve
For single phase alternating current, 100-130V Description • Motor technology: EC • Rated voltage UN: 1~100-130 V* • Rated frequency fN: 50/60 Hz* • Power input Psys: 0,31 kW* • Rated current Isys: 3,10-2,40 A* • Rated speed n: 2330 rpm* • Min. permitted ambient temperature tR: 5 °F / -15 °C • Max. permitted ambient temperature tR at nmax: • 140 °F / 60 °C • Electrical connection: Integrated controller • Number of blades : 6 • Balancing quality: G 6.3 • Protection class: IP54 • Motor
protection:
Integrated
active
temperature
management Impeller : High Performance Composite Material, uncoated, • RAL 9005 (jet black) • Certification: UL in process • * Rating plate data
Measured with inlet ring, without guard grille according to ISO 5801
DIMENSIONS (INCH)
14.61
Ø 11.5
9.53 8.15
12.68
Ø 6.46
M6
12.68 14.61 16.14
L-KL-3080-Vo-04
1.69
0.39
M6
L-KL-3080-04
3.15
Ø 9.84
Ø 7.4
Ø 5.91
4X90˚
0.39
8.15
Ø 0.28/6X60˚
Ventilation unit GR in installation position Vo
16.14
9.53
7.72 6.14 5
L-KL-3076-09
1.85
Ventilation unit GR in installation position H
Ø 0.35
Free-running motorized impeller RH in installation position H/Vu/Vo
FAN INFORMATION DATA
• Thermal class: THCL155*
20
EC motors have been used for many years in residential HVAC units, and have now become the norm for high efficiency light commercial HVAC applications as well. Comfort Flex offers Vertical Fan & Coil with EC motors. EC Motors significantly increases the operating efficiency of Comfort Flex fan coils, they also provide different control and performance capabilities. For each motor, fan speed control is accomplished through a microprocessor based controller that electronically controls the speed of the motor. These motors provide peak efficiency ratings between 70 & 80% for most applications. The first, full featured, EC motor offers continuously variable speed operation, constant airflow. This is achieved via proportional control from a remote 2 – 10V DC signal
FAN INFORMATION DATA
ECM FEATURES AND BENEFITS
21
• ULTRA- HIGH MOTOR & CONTROLLER ENERGY EFFICIENCY EC motors offer several advantages over PSC motors in fan Coils, including variable speed, constant CFM or constant Torque operation, and significantly higher efficiency. Due to the Permanent magnet rotor and electronic commutation, the EC Motor maintains approximately 75% efficiency at all speeds. Unlike a sleeve bearing motor, the ECM does not have a minimum RPM requirement for bearing lubrication. This allows it to operate over a much wider speed range, and provides for maintenance – free operation. A reduced spare parts inventory is another plus.
• EXTENDED MOTOR LIFE
The high motor efficiency provides a significantly reduced operating temperature compared to an induction motor. The lower temperature increases the longevity of all electrical components and therefore the life of the motor. The ball bearings do not require lubrication and do not adversely impact the motor life. Expected ECM life will be considerably longer than a PSC motor, due to the reduced operating temperature and ball bearing components.
â&#x20AC;˘ GENERAL FAN NOTES, VARIABLE EC MOTOR
Following chart show the fan amperes consumed at different control voltage inputs.
Following charts show the sound data of fan at different control voltage inputs.
FAN INFORMATION DATA
Following charts show the performance of the fan at different control voltage inputs.
22
Provide a standard factory supplied programmable Thermostat Modbus native.
• COMFORT FLEX FIXED FUNCTION THERMOSTAT
THERMOSTAT PACKAGES
Comfort Flex´s BACnet Logic Display Thermostat with fixed function is a non-programmable versión of the original VLD-362. There are two available fixed function models—the VLD-362-FF with fixed function and the wireless VLD-362FF-W with fixed function—that ship with 19 preloaded applications for specific and common projects including fan-coil, heat pump and air conditioning. The VLD-362-FF and VLD-362-FF-W are a communicating, intelligent sensor-controller combination with built-in temperature and humidity sensors used to control applications such as roof top units, fan-coil units and heat pumps. They provide a cost-effective solution for occupancy and crowd monitoring in hotel rooms, conference rooms, school portables and more.
of units using the user interface.
The thermostat meet in-room hotel requirements—an easyto-use interface, easy-to-see digital display, and Celsius/Fahrenheit change over. Direct digital control (DDC) enables flexible control of units, sophisticated, customizable displays, and an easy to use user interface. Pre-loaded applications enable fast configuration
The wireless version of the fixed function thermostat, combines a configurable display and a VisualLogic controller, making it ideal for retrofits of thermostat installations and places where a single-piece combination is easier to install. Its wireless capability offers the flexibility to chose different placements in a monitored space for máximum coverage. The thermostat communicate over an MS/TP LAN so each operates as a fully-functioning BACnet controller and easily integrates with the building automation system. This thermostat is a single, cost competitive unit with a familiar and user-friendly interface, so it’s a simple choice for customers who want an easy to use, wireless solution for occupancy-based sensing.
• FEATURES AND HIGHLIGHTS
• Flexible 19 pre-loaded applications for a quick, out-of-the-box solution. • Wireless option (VLD-362-FF-W) Integrated wireless receiver saves wiring time and costs, provides more location options. • Capable Internal temperature and humidity sensors, 3 universal inputs, 6 binary outputs, 2 analog outputs, factoryloaded applications. • Interoperable BACnet-compliant on MS/TP LAN at up to 76.8 Kbps. • Versatile Non-programmable versions that support Alerton DDC logic, capable of stand-alone or integrated operation. • Powerful Offers control of an additional VLC using peer-to-peer commands. Modes of operation allow control based on occupancy or schedules. • Fast Internal DDC logic loop of 100 msec.
23
• Visually appealing Sleek sophisticated design with touch screen display.
• TECHNICAL DATA • Power 24VAC power from a UL Listed Class-2 24VAC transformer (not provided). The VLD-362W uses a half-wave rectifier to convert the AC power supply to onboard power. This enables multiple devices with half-wave power supplies to be powered from a single, grounded transformer. Min. Load = 17VA (all BOs OFF). Max. Load = 89VA (all BOs ON). If BO power jumper is not removed, then all BOs are powered from the controller’s transformer. All BOs are N.O. (Normally Open) contacts with a maximum switch rating of 24VAC @ 0.5A (12VA). Maximum load assumes all 6 binary output loads are powered from the controller transformer and connected loads are the maximum allowed (24VAC @ 0.5A). Actual power requirements depend on connected loads. • Wireless Receiver: (VLD-362-FF-W version only) 433.92 Mhz; range is 50 feet. • Inputs: 3 universal inputs with 12-bit accuracy, providing controlled voltage, current and resistive modes. • Internal Sensors: 1 internal temperature sensor, 0–120 deg. F (-17.8–48.9 deg. C); 1 internal humidity, 5–95% RH, non-condensing. • Binary Outputs: 6 relay outputs; normally open contacts with a máximum switch rating of 24VAC @ 0.5A (12VA). BO-0, BO-2 and BO-5 are powered from the controller transformer. BO-1, BO-3 and BO-4 are powered from control transformer through removable jumper, allowing these BOs to be powered from a separate power source. • Universal Analog Outputs: 2 outputs with 12-bit resolution. Each auto-detects for 0–10VDC or 4–20mA. 4–20mA outputs are sourced by the VLD. Connected loads must return to the VLD ground. The VLD-362W automatically switches from 0–10V mode to 4–20mA current mode when it detects a load value of less than 500 Ohms. • Processor & Memory: Powerful 32-bit processor with extensive flash memory and RAM resources. Flash memory provides nonvolatile program and data storage, and allows for encrypted updates to the program for future product enhancements.
THERMOSTAT PACKAGES
Minimum load includes controller and analog outputs at full load (20mA into 500 Ohms).
24
GUIDE SPECIFICATIONS • GENERAL
DIMENSIONAL DATA
Furnish and install Comfort Flex Vertical Fan & Coil Units where indicated on the plans and in the specifications. Units shall be completely factory assembled, tested and shipped as one piece. All units shall be capable of meeting or exceeding the scheduled capacities for cooling, heating and air delivery. All unit dimensions for each model and size shall be considered maximums.
25
• CONSTRUCTION All unit chassis shall be fabricated of heavy gauge galvanized steel panels able to meet 125 hour salt spray test per ASTM B-117. All exterior panels shall be insulated with 1/2” thick insulation with a maximum k value of .24 (BTU • in) / (hr • ft2 • °F) and rated for a maximum air velocity of 5000 f.p.m. Insulation must meet all requirements of ASTM C1071 (including C665), UL 181 for erosion, and carry a 25/50 rating for flame spread/smoke developed per ASTM E-84, UL 723 and NFPA 90A. Option: For units with multiple outlets, include an insulated sheet metal baffle inside the discharge plenum to break the sight lines between the two discharge outlets and to attenuate room noise that could be transmitted through the openings. All unit panels shall have knockouts for supply air openings to facilitate the field supply air grille location. Option: Supply air opening knockouts shall be factory sealed and left in place during shipping and staging at the job site. All units shall have decorator front panels fabricated of not less than 18 gauge galvanized steel. The front panel shall include a stamped louver return air grille and be attached with quarter turn quick open fasteners to allow for easy removal and access for service. All concealed units shall have a duct collar on the discharge. All exposed units shall have exterior panels fabricated of not less than 18 gauge galvannealed steel. The front panel shall be attached with quarter turn quick open fasteners to allow for easy removal and access for service. Option: Provide an architectural grade double deflection aluminum discharge grille. Option: Provide foil faced insulation in lieu of standard. Foil insulation shall meet or exceed the requirements stated above, and in addition meet ASTM Standards C-665 and C-1136 for biological growth in insulation. Insulation shall be lined with aluminum foil, fiberglass scrim reinforcement, and 30 pound kraft paper laminated together with a flame resistant adhesive. All exposed edges shall be sealed to prevent any fibers from reaching the air stream. Option: Provide Elastomeric Closed Cell Foam Insulation in lieu of standard. Insulation shall conform to UL 181 for erosion and NFPA 90A for fire, smoke and melting, and comply with a 25/50 Flame Spread and Smoke Developed Index per ASTM E-84 or UL 723. Additionally, insulation shall comply with Antimicrobial Performance Rating of 0, no observed growth, per ASTM G-21. Polyethylene insulation is not acceptable.
• PAINT FINISH OPTIONS
• FILTERS
All painted cabinet exterior panels shall be finished with a heat cured anodic acrylic powder paint of the standard factory color.
All units shall be furnished with a minimum 1” nominal glass fiber throwaway filter. Filters shall be tight fitting to prevent air bypass. Filters shall be easily removable from the return air opening with the front panel removed, without the need for tools. Option: Provide unit with 1” pleated filter (MERV 8).
• SOUND
Units shall have published sound power level data tested in accordance with AHRI Standard 350-2000.
• FAN ASSEMBLY Unit fan shall be EC centrifugal fan with UL and CSA listed automatic reset thermal overload protection Single speed motors and three tap EC motors are not acceptable.
• ELECTRICAL
Units shall be furnished with single point power connection. Provide an electrical junction box with terminal strip for motor and other electrical terminations. The factory mounted terminal wiring strip consists of a multiple position screw terminal block to facilitate wiring terminations for the electric control valves and thermostats.
• ELECTRIC HEAT
All cooling and heating coils shall optimize rows and fins per inch to meet the specified capacity. Coils shall have seamless copper tubes and shall be mechanically expanded to provide an efficient, permanent bond between the tube and fin. Fins shall have high efficiency aluminum surface optimized for heat transfer, air pressure drop and carryover. All coils shall be hydrostatically tested at 600 PSIG air pressure under water, and rated for a maximum 300 PSIG working pressure at 200°F. Heating coils shall be furnished in the reheat position as standard. All water coils shall be provided with a manual air vent fitting to allow for coil venting. Option: Provide automatic air vents in lieu of manual air vents.
Furnish an electric resistance heating assembly as an integral part of the fan coil unit, with the heating capacity, voltage and kilowatts scheduled. The heater assembly shall be rated for installation on the fan coil unit and be located so as not to expose the fan assembly to excessive leaving air temperatures that could affect motor performance. The heater and unit assembly shall be listed for zero clearance and meet all NEC requirements, and be ETL listed with the unit as an assembly in compliance with UL/ANSI Standard 1995. All heating elements shall be open coil type Ni-Chrome wire mounted in ceramic insulators and located in an insulated heavy gauge galvanized steel housing. All elements shall terminate in a machine staked stainless steel terminal secured with stainless steel hardware for corrosion resistance. The element support brackets shall be spaced no greater than 3-1/2” on center. All internal wiring shall be rated for 105°C minimum. All heaters shall include over temperature protection consisting of an automatic reset primary thermal limit and back-up secondary thermal limit. All heaters shall be single stage.
• DRAIN PANS
Primary condensate drain pan shall be single wall composite and extend under the entire coil section. Drain pans shall be of one piece construction and be positively sloped for condensate removal. Option: Provide a removable primary drain pan to allow for inspection and cleaning. The drain pan shall be easily removed through the front panel without disturbing the coils. Drain pan access that requires removal of coils is not acceptable. Option: Provide a primary drain pan constructed entirely of heavy gauge type stainless steel for superior corrosion resistance. Stainless steel drain pans shall be externally insulated and meet or exceed the requirements stated above.
• PIPING PACKAGES
Provide a standard factory assembled valve piping package to consist of a 2 way proportional motorized electric control valve and two ball isolation valves. Control valves shall be piped normally closed to the coil. Maximum entering water temperature on the control valve shall be 200°F, and maximum close-off pressure 25 PSIG. Maximum operating pressure shall be 300 PSIG. Piping packages shall be completely factory assembled, including interconnecting pipe, and mounted inside the unit in a serviceable location over the coil and primary drain pan.
DIMENSIONAL DATA
• COILS
26
DIMENSIONAL DATA
ISOMETRIC DIAGRAMS
27
/ComfortFlexMexico Av. Central No. 285, Parque Logistico, Deleg. La Pila, San Luis Potosi, C.P. 78422 Mรกs Informaciรณn (444) 161.50.43 info@clima-flex.com service@clima-flex.com Lada sin costo 01 800 890 59 17 US Toll Free 01 800 201 48 16
/ComfortFlexMx /Comfort-Flex /ClimaFlex