Terminal Configurations F Series (Faston Tabs) H
Dimension
T
Type
F1 W
w
F2
L
L
W
6.50 mm 0.26 in 7.80 mm 0.31 in
4.75 mm 0.19 in 6.35 mm 0.25 in
L
W
14.0 mm 0.55 in 12.0 mm 0.47 in
2.00 mm 0.09 in 3.00 mm 0.12 in
w
H
T
6.00 mm 5.00 mm 0.24 in 0.20 in 7.80 mm 6.00 mm 0.31 in 0.24 in
0.80 mm 0.03 in 0.80 mm 0.03 in
T Series (Tab Terminal) Dimension Type
h
F1
H
L
F2
W
S Series (Spring Terminal) S1
w
h
12.5 mm 6.00 mm 0.49 in 0.24 in 12.5 mm 5.00 mm 0.49 in 0.20 in
6.00 mm 0.24 in 5.50mm 0.22 in
S Series (Spring Terminal) S2 7.00 mm 0.28 in
15.0 mm 0.59 in 9.00 mm 0.35 in
19.0 mm 0.75 in
19.0 mm 0.75 in 15.0 mm 0.59 in
P Series (Plastic Connector Terminal) P1
P Series (Plastic Connector Terminal) P2
22.0 mm 0.87 in
44.0 mm 1.73 in 11.1 mm 0.44 in
22.5 mm 0.89 in 6.20 mm 0.24 in
14.5 mm 0.57 in
L Series (L Type Terminal) Dimension Type
L1
h
L2
H
L3 L
W
L4 L5
L
W
17.5 mm 0.69 in 17.0 mm 0.69 in 25.5 mm 1.00 in 26.5 mm 1.04 in 26.5 mm 1.04 in
7.00 mm 0.28 in 9.00 mm 0.35 in 7.00 mm 0.28 in 8.00 mm 0.32 in 8.50 mm 0.34 in
H
h
17.0 mm 7.00 mm 0.69 in 0.28 in 17.0 mm 9.00 mm 0.69 in 0.35 in 22.0 mm 10.5 mm 0.87 in 0.41 in 24.5 mm 12.0 mm 0.97 in 0.47 in 24.0 mm 10.0 mm 0.95 in 0.39 in
8.50 mm 0.34 in 6.50mm 0.26 in 8.50 mm 0.34 in 9.00 mm 0.35 in 8.00 mm 0.32 in
Terminal Configurations Cont. Z Series (Z Post Terminal) 1
h
Dimension
H
1
Type
H
17.0 mm 8.00 mm 21.5 mm 9.00 mm 0.32 in 0.85 in 0.67 in 0.35 in
Z1
I Series (Internal Thread Terminal) Dimension Type
M
H
6.00 mm 0.24 in 6.00 mm 0.24 in 9.52 mm 0.37 in 6.00 mm 0.24 in 9.52 mm 0.37 in 6.00 mm 0.24 in 9.52 mm 0.37 in 10.0 mm 0.39 in 9.52 mm 0.37 in
H
M
13.0 mm 0.51 in 15.0 mm 0.59 in 16.0 mm 0.63 in 15.0 mm 0.59 in 17.0 mm 0.67 in 16.0 mm 0.63 in 16.0 mm 0.63 in 19.0 mm 0.75 in 19.0 mm 0.75 in
Marine Combo Post 7.92 mm 0.31 in 44.5 mm 1.75 in
10.0 mm 0.39 in 2.00 mm 0.08 in
29.5 mm 1.16 in
10.0 mm 0.39 in
2.00 mm 0.08 in
57.0 mm 2.24 in
12.0 mm 0.47 in 11.5 mm 0.45 in 22.0 mm 0.87 in
h
16.0 mm 0.63 in 18.0 mm 0.71 in 9.50 mm 0.37 in 10.0 mm 0.39 in
4.00 mm 0.16 in 3.00 mm 0.12 in 4.00 mm 0.16 in 4.00 mm 0.16 in 4.00 mm 0.16 in 4.00 mm 0.16 in 4.00 mm 0.16 in 2.00 mm 0.08 in 4.00 mm 0.16 in
Terminal Configurations Cont. Flag Terminal - FL1 30.8 mm 1.21 in 28.0 mm 1.10 in
25.0 mm 0.98 in
2.03 mm 0.08 in
12.5 mm 0.49 in
15.0 mm 0.59 in 12.5 mm 0.49 in
11.0 mm 0.43 in
15.0 mm 0.59 in
46.5 mm 1.83 in
Flag Terminal - FL2 25.0 mm 0.98 in 12.5 mm 0.49 in
8.00 mm 0.32 in
5.60 mm 0.22 in
29.5 mm 1.16 in
8.00 mm 0.32 in
36.2 mm 1.43 in 12.3 mm 0.48 in 10.2 mm 0.40 in 10.0 mm 0.39 in
54.9 mm 2.16 in Contact Us: TF: 866.892.1122 P: 469.892.1122 E: sales@upgi.com
Reduce Reuse Recycle
www.upgi.com NYSE Amex:UPG VR092209
<< Previous Page | Next Page >>
PANASONIC 6 VOLT LEAD-ACID BATTERIES
LEAD ACID
UPS/SPS SYSTEMS, EMERGENCY LIGHTING, ALARM SYSTEMS Part Number
Volts
LEAD-6V-1.3P LEAD-6V-2.4P LEAD-6V-3.2P LEAD-6V-3.4P LEAD-6V-4P LEAD-6V-4BP2 LEAD-6V-4P-250 LEAD-6V-4PW LEAD-6V-4.2P LEAD-6V-5P LEAD-6V-6.5P LEAD-6V-7.2P LEAD-6V-7.2BP2 LEAD-6V-7.2P-250 LEAD-6V-10P LEAD-6V-10P-250 LEAD-6V-12P LEAD-6V-12BP2 LEAD-6V-12P-250
6
6 6 6 6 6 6 6 6 6
6 6 6
Capacity 20Hr. Rate
1.3 NLA NLA 3.4 NLA 4.0 4.0 4.0 4.2 5.0 NLA 7.2 7.2 7.2 NLA NLA 12.0 12.0 12.0
— — —
—
— —
Dimensions (Inches) Height Length Width Inc. Term
3.82 USE LEAD USE LEAD 5.28 USE LEAD 2.76 2.76 2.76 2.76 2.76 USE LEAD 5.95 5.95 5.95 USE LEAD USE LEAD 5.95 5.95 5.95
Weight (Lbs)
.94 2.16 6-2.8PS (POWERSONIC) 6-3.2PS (POWERSONIC) 1.34 2.60 6V-4.2P 1.85 4.26 1.85 4.26 1.85 4.26 1.85 4.26 1.85 4.26 6V-7.2P 1.34 3.94 1.34 3.94 1.34 3.94 6V-12P 6V-12P-250 1.97 3.94 1.97 3.94 1.97 3.94
.66
1.37 1.98 1.98 2.10 1.98 2.14 2.78 2.78 2.78
4.30 4.30 4.30
NOTES
100
Cross Refference
Termination
LC-R061R3P, LCR6V1.3P LC-R062R4PU LC-R063R2PU LC-R063R4P, LCR6V3.4P LC-R064P LC-R064P2 LC-064P1 LCR6V4PL LC-R064R2P LC-065P LCR-6V-6.5BP LC-R067R2P, LCR6V7.2P LC-R67R2-P2 LC-R67R2-P1 LCR-6V-10BP LCR-6V-10BP1 LC-R0612P, LCR6V12P LC-R0612P2 LC-R0612P1
.187 TAB
.187 TAB .187/.250 TAB .250 TAB WIRE & CONN .187 TAB .187 TAB .187 TAB .187/.250 TAB .250 TAB
.187 TAB .187/.250 TAB .250 TAB
PANASONI COEM
<< Previous Page | Next Page >>
PANASONIC 12 VOLT LEAD-ACID BATTERIES
Part Number
Volts
12 12 12 12 12
1.3 2.0 2.0 2.2 3.4
Dimensions (Inches) Height Length Width Inc. Term
Weight (Lbs)
Cross Refference
3.82 1.87 2.16 1.30 LC-R121R3P, LCR12V1.3P 6.97 .94 2.52 1.40 LC-T122PU 7.17 .94 2.42 1.40 LC-TA122PU 6.97 1.34 2.60 1.76 LC-R122R2P, LCR12V2.2P 5.28 2.64 2.60 2.65 LC-R123R4P, LCR12V3.4P NLA — USE LEAD 12V-5P LC-RB124P 12 5.0 3.54 2.76 4.26 4.25 LC-R125P, LCR12V5P NLA — USE LEAD 12V-7.2P LCR-12V-6.5P NLA — USE LEAD 12V-7.2P-250 LCR-12V-6.5P1 12 7.2 5.95 2.54 3.94 5.45 LC-R127R2P, LCR12V7.2P 12 7.2 5.95 2.54 3.94 5.45 LC-R127R2P1 12 12.0 5.95 3.86 3.90 8.30 LC-R1212P, LCR12V12PF, LC-RA1212P 12 17.0 7.13 2.99 6.57 14.3 LC-RC1217P, LCR12V17CP, LC-RD121D 12 20.0 7.13 2.99 6.57 14.5 LC-X1220P NLA — USE LEAD 12V-28PB (NOTE REVERSED POSITIVE AND NEGATIVE) LCR-12V-24P 12 28.0 6.50 4.90 7.10 24.30 LC-X1228P 12 28.0 6.50 4.90 6.90 24.30 LC-X1228AP 12 33.0 7.70 5.12 7.09 26.5 LC-LA1233P, LCL12V33AP NLA — USE LEAD 12V-42P LCR-12V-38P 12 42.0 7.75 6.49 7.08 35.20 LC-X1242P 12 42.0 7.75 6.49 7.08 35.20 LC-X1242AP 12 65.0 13.78 6.54 6.89 44.1 LC-L1265P, LCL12V65P,LC-X1265P 12 100.0 16.03 6.82 9.29 72.8 LCR12V100AP, LC-XA12100P
Part Number
Capacity Volts 20Hr. Rate
Dimensions (Inches) Height Length Width Inc. Term Weight (Lbs)
Cross Refference
Termination
.187 TAB .187 TAB PRESSURE .187 TAB .187 TAB .187 TAB
.187 TAB .250 TAB .250 TAB NUT & BOLT NUT & BOLT NUT & BOLT THREADED POST NUT & BOLT NUT & BOLT THREADED POST NUT & BOLT NUT & BOLT Termination
HIGH POWER SERIES LEAD-UPRW1220P LEAD-UPRW1220P-250 LEAD-UPRW1245P LEAD-UPRW1245P-250
12 12 12 12
20.0 20.0 45.0 45.0
5.51 5.51 5.95 5.95
1.51 1.51 2.54 2.54
3.99 3.99 3.99 3.99
2.98 2.98 5.73 5.73
NOTES
101
UP-RW 1220P UP-RW1220P1 UP-RW1245P UP-RW1245P1
.187 .250 .187 .250
TAB TAB TAB TAB
LEAD ACID
LEAD-12V-1.3P LEAD-12V-2P LEAD-TA122PU LEAD-12V-2.2P LEAD-12V-3.4P LEAD-12V-4P LEAD-12V-5P LEAD-12V-6.5P LEAD-12V-6.5P-250 LEAD-12V-7.2P LEAD-12V-7.2-250 LEAD-12V-12P LEAD-12V-17P LEAD-12V-20P LEAD-12V-24PB LEAD-12V-28PB LEAD-12V-28PTP LEAD-12V-33P LEAD-12V-38P LEAD-12V-42P LEAD-12V-42PTP LEAD-12V-65P LEAD-12V-100P
Capacity 20Hr. Rate
Engineered With Vision. Built With Care.
Power-Sonic has more than 38 years of battery industry experience and today our batteries are sold in more than 70 countries world-wide. Since our inception in 1970, our focus has been the design, manufacture and marketing of rechargeable batteries, specifically:
• Sealed lead-acid (SLA), also called valve regulated leadacid (VRLA) batteries • Powersport batteries • Sealed nickel-cadmium (NiCd) and nickel-metal hydride (NiMH) batteries • NiCd and NiMH configured packs (cell assemblies) • SLA battery chargers • NiCd and NiMH battery chargers
Our products are widely used in an ever broadening range of electronic and industrial applications. Our batteries continue to be used wherever cost effective and reliable DC power is required, be it as the principal power or standby power source. Our aim is the ongoing improvement of our existing products, coupled with the development of new tailored products, to meet the ever increasing needs for stand alone power. Our advanced engineering techniques and state-of-the-art manufacturing processes ensure that we remain on the cutting edge of battery technology. These skills, coupled with our selection of the finest raw materials, allow us to produce batteries combining superior performance and value. Providing our customers with reliable, yet economical, products is the cornerstone of our mission.
Features Sealed/Maintenance-Free
Long Service Life
Valve Regulated Design
Deep Discharge Recovery
The valve regulated, spill-proof construction allows troublefree, safe operation in any position. There is no need to add electrolyte, as gases generated during overcharge are recombined in a unique “oxygen cycle.”
Our batteries incorporate a series of one-way low pressure valves. These self sealing valves allow the venting of any excess gasses that may be produced in the battery due to severe overcharging. Valve regulated batteries should never be recharged inside a sealed container.
Design Flexibility
Batteries may be used in series and/or parallel to obtain choice of voltage and capacity. Due to recent design breakthroughs, the same battery may be used in either cyclic or standby applications. Over 60 models are available to choose from.
Compact
Power-Sonic batteries use state-of-the-art design, high grade materials, and a carefully controlled plate-making process to provide excellent output per cell. The high energy density results in superior power/volume and power/weight ratios.
Rugged Construction
The high impact resistant battery case is made of nonconductive ABS plastic to UL94-HB. This material imparts very good resistance to shock, vibration, chemicals and heat. Certain models feature flame retardant (FR) cases/covers to UL94 V-O.
Wide Operating Temperature Range
Power-Sonic batteries may be discharged over a temperature range of -40°C to +60°C (-40°F to +140°F) and charged at temperatures ranging from -40°C to +50°C (-40°F to +122°F).
We’ve Got The Power.™
Under normal operating conditions, four or five years of dependable service life can be expected in stand-by applications, or between 200 and 1000 charge/ discharge cycles depending on the average depth of discharge.
Special separators, advanced plate composition, and a carefully balanced electrolyte system have greatly improved the ability to recover from excessively deep discharge.
Lead Calcium Plates
Heavy duty lead calcium plates provide an extra margin of performance and life in both cyclic and float applications and give unequaled recovery from deep discharge.
Economical
The high watt-hour per dollar value is made possible by the materials used in a sealed lead-acid battery: they are readily available and low in cost.
Operation in any Orientation
Our SLA batteries can be discharged in any orientation, without reduction in performance or leakage of electrolyte.
High Rate Discharge
Low internal resistance allows discharge currents of up to ten times the battery’s rated capacity. Relatively small batteries may thus be specified in applications requiring high peak currents.
Long Shelf Life
A low self discharge rate allows storage of fully charged batteries for extended periods of time before charging is required. Lower storage temperatures further enhance shelf life characteristics.
PS and PSG-SERIES: General Purpose Batteries Nominal Voltage V
Nominal Capacity A.H.
Current @ 20-hr. rate mA
in.
PS-260
2
6.0
300
1.97
50
1.34
34
3.94
100
4.13
PS-445
4
4.5
225
1.89
48
2.09
53
3.70
94
3.86
PSG-450
4
5.0
250
3.54
90
1.94
49
2.87
73
PSG-480
4
8.0
400
3.54
90
1.94
49
4.00
PS-490
4
9.0
450
4.01
102
1.73
44
3.74
PS-4100
4
10.0
500
4.01
102
1.97
50
PS-605
6
0.5
25
2.24
57
0.55
PS-610
6
1.1
55
2.00
51
PS-612
6
1.4
70
3.82
97
PSG-625
6
2.5
125
4.15
PS-628
6
2.9
145
PS-630
6
3.5
PS-632
6
3.5
PS-640
6
PS-650LS & LF
Length
Width
Height
Ht. Over Terminal
Weight lbs.
kgs.
Standard Terminals
105
0.89
0.40
F1
98
1.30
0.59
F2
2.87
73
1.40
0.64
F2
102
4.00
102
2.09
0.95
F2
95
4.02
102
2.20
1.00
F2
3.70
94
3.85
98
2.50
1.13
F1
14
1.97
50
1.97
50
0.20
0.09
WL
1.65
42
2.00
51
2.20
56
0.44
0.20
F1
0.94
24
2.00
51
2.20
56
0.66
0.30
F1
105
1.63
41
2.70
69
2.70
69
1.17
0.53
F1
2.60
66
1.30
33
3.86
98
4.06
103
1.30
0.59
F1
175
5.28
134
1.34
34
2.35
60
2.56
65
1.37
0.62
F1
175
2.60
66
1.30
33
4.65
118
4.80
122
1.37
0.62
F1
4.5
225
2.76
70
1.86
47
3.94
100
4.25
108
1.60
0.73
F1
6
5.0
250
2.64
67
2.64
67
3.94
100
4.64
118
1.80
0.82
F1 or SP
PSG-650
6
5.0
250
5.28
134
1.94
49
3.00
76
3.00
76
2.15
0.98
F2
PS-665
6
6.5
325
3.86
98
2.20
56
3.78
96
4.02
102
2.70
1.22
FP
PS-670
6
7.0
350
5.95
151
1.34
34
3.70
94
3.94
100
2.42
1.10
F1
PSG-680
6
8.0
400
5.28
134
1.94
49
3.98
101
3.98
101
3.19
1.45
F2
PS-682
6
9.0
450
3.86
98
2.20
56
4.65
118
4.72
120
3.20
1.45
F1
PS-6100
6
12.0
600
5.95
151
2.00
51
3.70
94
3.86
98
4.30
1.95
F1 or F2
PS-6120FP
6
13.0
650
4.25
108
2.80
71
5.55
141
5.55
141
4.80
2.18
FP
PS-6120 Toy
6
13.0
650
4.25
108
2.80
71
5.55
141
5.55
141
4.80
2.18
TH or TS
PS-6200
6
20.0
1000
6.18
157
3.27
83
4.92
125
4.92
125
7.10
3.22
NB1
PS-6360
6
36.0
1800
6.25
159
3.35
85
6.50
165
6.93
176
12.10
5.49
F2 or NB1
PS-6580
6
58.0
2900
7.28
185
4.41
112
8.07
205
8.07
205
19.50
8.85
F2
PS-62000
6
210.0
10500
12.05
306
6.65
169
8.65
220
8.96
228
63.93
29.00
T8
PS-832
8
3.2
160
5.29
134
1.42
36
2.49
63
2.70
69
1.65
0.75
F1
PS-1208
12
0.8
40
3.78
96
0.98
25
2.44
62
n/a
n/a
0.77
0.35
WL
PS-1212
12
1.4
70
3.78
96
1.69
43
2.04
52
2.28
58
1.20
0.54
F1
PS-1220
12
2.5
125
7.00
178
1.38
35
2.36
60
2.56
65
2.10
0.95
F1
PS-1221
12
2.0
100
5.63
143
0.94
24
2.56
65
2.56
65
1.30
0.59
PC
PS-1221S
12
2.0
100
5.91
150
0.80
20
3.52
89
n/a
n/a
1.50
0.68
F1/0
PS-1223
12
2.3
115
7.17
182
0.94
24
2.40
61
2.40
61
1.70
0.77
PC
PS-1227
12
2.9
145
3.11
79
2.20
56
3.90
99
4.13
105
2.40
1.09
F1
PS-1228
12
2.8
140
5.24
133
1.30
33
3.82
97
4.09
104
2.60
1.18
F1
PS-1229
12
2.9
145
7.00
178
1.38
35
2.36
60
2.60
66
2.30
1.04
F1
PS-1230
12
3.4
170
5.24
133
2.64
67
2.36
60
2.60
66
2.90
1.32
F1
PS-1238
12
3.8
190
7.68
195
1.85
47
2.91
74
2.91
74
3.50
1.59
F1
PS-1250
12
5.0
250
3.54
90
2.76
70
3.98
101
4.21
107
3.50
1.59
F1 or F2
PS-1251FP
12
5.4
270
5.50
140
1.90
48
4.00
102
4.06
103
4.10
1.86
FP
PS-1270
12
7.0
350
5.95
151
2.56
65
3.70
94
3.86
98
4.80
2.18
F1 or F2
PS-1272
12
7.2
360
5.95
151
2.56
65
3.70
94
3.86
98
5.80
2.63
F1 or F2
PS-1282L
12
9.0
450
7.72
196
2.20
56
4.65
118
4.65
118
6.90
3.13
F1
PS-1282S
12
9.0
450
3.86
98
4.40
112
4.65
118
4.65
118
6.90
3.13
F1
PS-1290
12
8.5
425
5.95
151
2.56
65
3.70
94
3.86
98
6.00
2.72
F2
PS-12100
12
12.0
600
5.95
151
4.00
102
3.70
94
3.86
98
8.14
3.69
F1 or F2
PS-12120
12
12.0
600
5.95
151
3.86
98
3.70
94
3.94
100
7.92
3.59
F2
PS-12120L
12
12.0
600
8.45
215
2.75
70
5.75
146
5.75
146
8.80
3.99
FP
PS-12140
12
14.0
700
5.95
151
3.86
98
3.70
94
3.94
100
9.25
4.20
F2
PS-12180
12
18.0
900
7.13
181
3.00
76
6.59
167
6.59
167
12.60
5.72
F2 or NB2
Model
* FR: UL94 V-0 flame retardant case & cover
mm
in.
mm
in.
mm
in.
mm
All data subject to change without notice.
POWER-SONIC Rechargeable Batteries
PS and PSG-SERIES: General Purpose Batteries (continued) Nominal Voltage V
Nominal Capacity A.H.
Current @ 20-hr. rate mA
in.
PS-12260
12
26.0
1300
6.56
PS-12280
12
28.0
1400
6.50
PS-12350
12
35.0
1750
PS-12400
12
40.0
PS-12550
12
PS-12750
Model
Length
Width
Height
Ht. Over Terminal
Weight lbs.
kgs.
Standard Terminals
125
17.00
7.71
F2 or NB2
177
20.70
9.39
NB1
7.00
178
24.70
11.20
NB3
170
6.69
170
29.10
13.20
NB4
8.15
207
8.98
228
36.00
16.33
U
168
8.15
207
8.98
228
50.60
22.95
U
6.60
168
8.15
207
8.98
228
68.00
30.84
U
330
6.73
171
8.35
212
8.66
220
69.50
31.52
T11
343
6.73
171
10.80
274
11.15
283
99.00
44.91
T11
mm
in.
mm
in.
mm
in.
mm
167
6.97
177
4.92
125
4.92
165
4.92
125
6.97
177
6.97
7.72
196
5.14
131
6.22
158
2000
7.76
197
6.50
165
6.69
55.0
2750
9.04
230
5.45
138
12
75.0
3750
10.25
260
6.60
PS-121000
12
100.0
5000
12.00
305
PS-121100
12
110.0
5500
13.00
PS-121400FR*
12
140.0
7000
13.50
* FR: UL94 V-0 flame retardant case & cover
PSH-SERIES: High-Rate Discharge Batteries • High capacity versions of standard size models designed primarily for high rate discharge applications. • Exceptionally high energy density (watt-hours per cubic inch). • Low internal resistance, well suited for short duration high rate discharge PSH-655 FR*
6
5.5
275
2.76
70
1.85
47
3.94
100
4.17
106
2.10
0.95
F1
PSH-1255 FR*
12
6.0
300
3.54
90
2.76
70
3.98
101
4.21
107
4.00
1.81
F2
PSH-1280 FR*
12
8.5
425
5.94
151
2.56
65
3.70
94
3.86
98
6.00
2.72
F2
PSH-12100 FR*
12
10.5
550
5.94
151
2.56
65
4.37
111
4.61
117
7.00
3.18
F2
PSH-12180 FR*
12
21.0
1050
7.14
181
3.03
77
6.59
167
6.59
167
13.20
5.99
NB2
* FR: UL94 V-0 flame retardant case & cover
Terminal Options
FASTON
12
19
17.5
Positive
Negative
12
M6
14
NB2
T8
6
13
THREADED INSERT - 6mm STUD 20mm M6
Torque: 3.9~5.4 Nxm
6mm
SPRING TERMINALS
6
16.5
NB3 7
Fully collapsible positive and negative contacts
Torque: 3.9~5.4 Nxm
2
4.5
4.8
6mm
21
16
Torque: 3.9~5.4 Nxm
T11 THREADED INSERT - 8mm STUD
6
20mm M8
TOY BATTERY CONNECTORS
TH
8.5
16mm
Torque: 2.0~3.0 Nxm
0.6
SP
13
2
Positive: “F2”, Negative: “F1”
6
9
T6 THREADED INSERT - 6mm STUD
4.8
NB1
FASTON POLARIZED
F1/0
13
15.9
Torque: 11.0~14.7 Nxm
0.250" x 0.032" quick disconnect tabs
FP
17.4 10
• Molex Housing 5264-02 & 5263-PBT plug on PS-605 • AMP Housing 1-480318-0 & 8116-1 on PS-1208
U
22 18
F2
INSULATED WIRE LEADS
22 18
0.187" x 0.032" quick disconnect tabs.
WL
10
FASTON
5.6
F1
H-connector PS-6120 TH
Torque: 3.9~5.4 Nxm
7mm Torque: 11.0~14.7 Nxm
PC
S-connector PS-6120 TS
PRESSURE CONTACTS
7.5
TOY BATTERY CONNECTORS
TS
5.5
15
NB4
18
6
Torque: 3.9~5.4 Nxm
T12 THREADED INSERT - 5mm STUD 12mm M5 6mm Torque: 2.0~3.0 Nxm
All data subject to change without notice.
We’ve Got The Power.™
POWER-SONIC Rechargeable Batteries
hrs
Discharge Time (hrs)
6
.01
12
18
24
42 36 30
54
1
2
3
4
6 5
8
10
20
30
40
2.0AH 2.5AH
1.1AH 1.4AH
0.8AH
0.5AH
.02
.03
.05
.07 .10
Ambient temp. 20o C (68o F)
.2
10.0AH .5 .6
18.0AH
35.0AH 2
55.0AH 3
75.0AH 4 5 6
The graph above shows capacity curves for major Power-Sonic battery models with different ampere-hour ratings. Amperage is on the horizontal scale and the time
8 10
20
200
300
500
Discharge times reflect cut-off voltages which vary with the discharge current: LOAD FINAL CURRENT VOLTAGE 0.05C 1.75V/Cell 0.10C 1.75V/Cell 0.20C 1.75V/Cell 0.50C 1.70V/Cell 1.00C 1.50V/Cell 2.00C 1.35V/Cell "C" = Capacity of battery
30 40 50 60 80 100
20.0AH
1000
elapsed is on the vertical scale; the product of these values is the capacity. Proper selection of the battery for a specific application can be made from this graph if the required time and current are known. For example, to determine the proper capacity of a battery providing 3 amps for 30 minutes, locate the intersection of these values on the graph. The curve immediately above that point represents the battery which will meet the requirement.
Discharge Current (Amps)
.8 1
26.0AH
When a battery discharges current at a constant rate, its capacity changes according to the amperage load. Capacity increases when the discharge current is less than the 20-hour rate and decreases when the current is higher.
.3
110.0AH 140.0AH
2.3AH 2.9AH
50
3.5AH 4.5AH 5.5AH 7.0AH
CAPACITY VARIATION BY CURRENT LOAD
min
Discharge Time as a Function of Discharge Current 210.0AH 5.0AH 6.5AH 8.0AH
60
12.0AH
80
40.0AH
100
65.0AH
Performance Characteristics Life Characteristics in Cyclic Use
Life Characteristics in Stand-by Use
120
Retention Capacity (%)
Retention Capacity (%)
100 80 60
Discharge Depth 100%
Discharge Depth 50%
Discharge Depth 30%
40 1. Discharge Current 0.2C (Final Voltage 1.7V/Cell) 2. Charge Current: 0.1C 3. Ambient Temperature: 20 o C to 25 o C (68 o F to 77 o F)
20
Ambient Temperature 20˚C (68˚F)
100 80 60
Float Charging Voltage 2.25 - 2.30 V/Cell
40 20 0
0
Years
Number of Cycles
Characteristic Discharge Curves
6.5
13
6.5
13
6.0
12
6.0
12
5.5
11
5.5
11
5.0
10
4.5
9
4.0
8
5.0
10
4.5
9
4.0
8 0
0.175C 0.1C 0.05C 0.25C 0.6C
3C 2C 1
2
3
5
10 min
Battery Voltage (V)
Battery Voltage (V)
Characteristic Discharge Curves
0.175C 0.1C 0.05C 0.25C 0.6C
1C 20 30
60
2
3
5 h
10
0
20 30
3C 1
2
5
3
Discharge Time @ 20°C (68°F)
Effect of Temperature on Capacity
80
0.50 C 1C
60 40 20
0
10
20
30
40
2
3
5 h
10
20 30
50
60
Charging is not necessary unless 100% of capacity is required.
80
Charging before use is necessary to recover full capacity.
5°C (41°F) 60 40°C (104°F)
40 0
0 -10
60
100
Capacity Retention Ratio (%)
Percent(%) of Capacity
0.05 C 0.10 C 0.25 C
-20
20 30
Self-Discharge Characteristics
110
-30
10 min
Discharge Time @ 0°C (32°F)
120
-40
1C
2C
0
2
4
6
8
10
12
Charge may fail to restore full capacity. Do not let battery reach this state
20°C (68°F)
30°C (86°F) 14
16
18
20
Storage Period (Months)
Temperature (°C)
Charging
Cycle Applications: Limit initial current to 0.30C (C is the nominal amp hour capacity of the battery) or 30 amps, which ever is the less. Charge until battery voltage (under charge) reaches 2.45 volts per cell at 68°F (20°C). Hold at 2.45 volts per cell until current drops to approximately 0.01C ampere. Battery is fully charged under these conditions, and charger should either be disconnected or switched to “float” voltage.
Because there is a chance of off-gassing hydrogen and oxygen if the battery is overcharged, it is important to provide adequate air circulation. Never charge or discharge a battery in a hermetically sealed enclosure.
“Float” or “Stand-by” Service: Hold battery across
Batteries should not be stored in a discharged state (or in a hot place). If a battery is discharged for some time it may not readily take a charge. To overcome this, leave the charger connected and the battery should eventually begin to accept a charge.
Application Notes
Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. To prolong shelf life without charging, store batteries at 50°F (10°C) or less.
constant voltage source of 2.25 to 2.30 volts per cell continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition.
Continuous over- or undercharging is the single worst enemy of a lead-acid battery. Caution should be exercised to insure that
the charger is disconnected after cycle charging, or that the float voltage is set correctly.
We’ve Got The Power.™
Battery Construction Terminals
Relief valve
Depending on the model, batteries come either with AMP Faston type terminals made of tin plated brass, post type terminals of the same composition with threaded nut and bolt hardware, or heavy duty flag terminals made of lead alloy. A special epoxy is used as sealing material surrounding the terminals.
In case of excessive gas pressure build-up inside the battery, the relief valve will open and relieve the pressure. The one-way valve not only ensures that no air gets into the battery where the oxygen would react with the plates causing internal discharge, but also represents an important safety device in the event of excessive overcharge. Vent release pressure is between 2-6 psi; the seal ring material is neoprene rubber.
Plates (electrodes)
Power-Sonic utilizes the latest technology and equipment to cast grids from a lead-calcium alloy free of antimony. The small amount of calcium and tin in the grid alloy imparts strength to the plate and guarantees durability even in extensive cycle service. Lead dioxide paste is added to the grid to form the electrically active material. In the charged state, the negative plate paste is pure lead and that of the positive lead dioxide. Both of these are in a porous or spongy form to optimize surface area and thereby maximize capacity. The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge
Separators
Power-Sonic separators are made of non-woven glass fiber cloth with high heat and oxidation resistance. The material further offers superior electrolyte absorption and retaining ability, as well as excellent ion conductivity.
Container & case sealing
Case and lid material is ABS, high impact, resin with high resistance to chemicals and flammability. Case and cover are made of non-conductive ABS plastic to UL94-HB or UL94 V-O. Depending on the model the case sealing is ultrasonic, epoxy or heat seal.
Electrolyte
Immobilized dilute sulfuric acid: H2S04.
Typical Applications Power Sources • Back-up power • Computers • UPS
Communications
• GPS equipment • Marine communications • Telecommunication systems
Lighting
• Emergency lighting • Exit lights • Hand held lights
Security Systems
• Burglar / Fire alarms • Monitoring alarms • Metal detectors
Automotive
Agricultural
Recreation
Military
Portable Equipment
Miscellaneous
• Electronic memory accessories • Braking / Fuel systems • Fish finders • Ride-on toys • Electrical bicycles/scooters • Audio-visual devices • Test and measuring equipment • Consumer electronics
Monitoring Equipment • Fiber-optic test equipment • Scientific instruments • Weather instrumentation
• Livestock/game feeders • Containment fencing • Aerospace • Aircraft instrumentation • Fire control systems • Invisible fences • DC power lifts • Floor scrubbers • Laser products • Robotics • Advertising signs
Battery Chargers Power-sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to the Charger Selection Guide in our specification sheets for “C-Series Switch Mode Chargers” and “Transformer Type A and F Series”. Please contact our technical department for advice if you have difficulty in locating suitable models.
POWER-SONIC Rechargeable Batteries
Quality is always #1 We employ IQC, PQC and ISO 9001 Quality Management Systems to test materials, monitor manufacturing processes and evaluate finished products prior to shipment. All our batteries are 100% tested with advanced computer equipment prior to being released for sale. Power-Sonic management and staff are committed to providing the best possible service to satisfy our customer’s needs, and fulfill our undertaking to deliver top grade products on time and at a competitive price.
Our batteries are manufactured to international standards including JIS, DIN and IEC and have UL and CE certification.
Corporate Headquarters and Domestic Sales Power-Sonic Corporation • 7550 Panasonic Way • San Diego, CA 92154 • USA Phone: (619) 661-2020 • Fax: (619) 661-3650 Email Sales: national-sales@power-sonic.com • Email Customer Service: customer-service@power-sonic.com International Sales Power-Sonic Corporation • P.O. Box 5242 • Redwood City, CA 94063 • USA Phone: (650) 364-5001 • Fax: (650) 366-3662 Email Sales: international-sales@power-sonic.com European Sales Power-Sonic Europe, Ltd. • 3 Buckingham Square, Hurricane Way • Wickford, Essex SS11 8YQ • England Phone: (1268) 560686 • Fax: (1268) 560902 Email Sales: sales@power-sonic.co.uk • Website: www.power-sonic.co.uk
www.power-sonic.com © Copyright 2011. Power-Sonic Corporation. All rights reserved. REV0611