NC State Graduate School & Poole College of Management Building ARC501 - Fall 2021
Dottie Sloan
Harvard Univ. Science & Engineering Complex Behnisch Architekten, Boston (2021 Completion)
Emory Univ. Campus Life Center Duda Paine Architects, Atlanta (2019)
Scheme 1 Fitts-Wollard Hall
The Oval Lakeview Hall 358’
Gr
ov
Hall
SITE 329’ Hunt Library
60’
180’
343’
Open Offices 373’ /Workspace
388’
/Library
373’ & Open Classrooms
343’
60’
343’
120’
60’
120’
60’
120’
e
60’
120’
Scheme 2 Fitts-Wollard Hall
The Oval
LakeviewHall 358’
Gr
ov
e
Hall
SITE 343’
329’
Hunt Library
60’
180’
Upper Plaza 358’
373’ Mechanical
388’
Grad Open Work Lobby/Graduate Offices
Shared Classrooms
Lounge/Cafe
Open Offices/ Workspace
Career Services
Open Offices/ Workspace
Classrooms/Study
Lower Plaza 343’
Poole Lecture & Classrooms
60’
Open Office & Classrooms
Poole Offices/ Library
120’
60’
240’
60’
Admin Offices
120’
60’
120’
Scheme Comparison Scheme 1
Relationship to Oval Addresses Change in Topography Properly Utilizes Open Public Space Proper Relationship to Dorm Accessibility Accounts for Solar Orientation Appropriate Square Footage Effective Program Layout
Scheme 2
Design Proposal
Parti
Vicinity Map E.B. 2
E.B. 1
E.B. 3
The Oval FittsWoolard Hall
Lakeview Hall
all
eH
ov
Gr
Hunt Library
100’
y Valle
300’
600’
Hall
Site Plan
Fitts-Woolard Hall
The Oval Lakeview Hall
ov
Gr
358’
all
eH
2
1
335’
Hunt Library
1 - Service Drive 2 - Service Entry - Public Entry
50’
200’
Ground Level Poole Graduate Shared Service/Storage Circulation
60’
180’
Level 1
60’
180’
Level 2
60’
180’
Level 3
60’
180’
Roof
60’
180’
Elevations
North Elevation
West Elevation (Facing Oval)
Sections
Section 1
Section 2
Birdseye from Oval
Birdseye from Oval
Entry at Oval Level
Entry at Oval Level
Top of Ramp
Patio from Grad School
Ground Level of Atrium
Bottom of Ramp
Garden Level
Chunk Model
Wall Section
Structure Level 2 Connected to protected steel columns, this structural system is based on a 30’x30’ grid, with open web steel joists connecting to each of the beams.
HVAC Plan Chilled Water (Chiller) System - Water Cooled A water loop in the chiller cools air that is circulated by the Air-Handling Unit, while the boiler heats a coil that heats this circulated air when needed. The cooling tower helps to remove unwanted heat through this system. An air recovery ventilator aids in the exchange of fresh and stale air from the outside.
HVAC Section
Code
Stair Width ADA Min. Width: 60” 312.4 occupants X .3” = 93.72” for stair Each stairwell (3) is 72” wide. -Total 216” provided 312.4” X .2” = 62.48 min. corridor width -Smallest corridor shown is 66” wide
Travel Distance Max. Dead-End Corridor
Common Path of Travel
Level 2 Fire Diagram
Accessibility In an effort to make this structure available to all, there is a heavy emphasis on making it as accessible as possible. Every person, no matter what their level of ability or disability, should move through the spaces in this building the same way. The strong axis connecting The Oval to the trails and vegetative space on the ground level is intended to be a long and thoughtful walk, causing an individual to feel the large scale of these buildings, and to move toward an open space in nature beyond. I wanted to make sure everyone could go on this journey, no matter which direction of travel. Not only are there stairs, but there is an accompanying ramp for those who need it. At every landing there is a connection between the two, allowing users to determine their own path of travel. 1 - Area of Refuge: Every stairwell has two spaces for an area of refuge, with each space meeting the min. requirements of being 30”x48”, while maintaining the required egress width. 2 - Outdoor ramp becomes part of experience of moving between buildings. Follows 1:12 ratio, and thoughtfully incorporates connection to stairs at the required 30’ landing placement. 3 - Ramp in atrium allows ALL individuals to experience this open space. Follows 1:12 ratio and aligns with outdoor ramp 30’ landing requirements. 4 - Min. corridor width: 63”. ADA Min. Width: 60” 5 - Elevators smartly located in central vertical circulation areas. Door width: 48” (ADA min: 36“), Car dimensions: 86”x75” (ADA min: 80”x54”) 6 - Common work spaces wide enough for tables and passage through, with railing space for anyone to access to view into atrium. 7 - All entries on Level 1 and Ground level to be level with the outside for ease of entry and exit from buildings. 8 All toilet rooms ADA compliant with handicapped stalls and 5’ diameter turn-around allowance 9 - Grad school patio is level with walkways for anyone to access and use.
1
6 4
7
3 2
7
5
9 8
5
Landing within Atrium
From Oval