Portfolio of Architecture Dian Mashita Eddy Suryono
Selected Professional Works 2016-2022 BILLARD LEECE PARTNERSHIP, MELBOURNE ‘19-’22 HAYBALL, MELBOURNE ‘18 SKEMATICS ARCHITECTS, MELBOURNE ‘16-’18
1
Hello & Salam!
“Service to others is the rent you pay here on earth” - Muhammad Ali “We shape our buildings, thereafter they shaped us” - Winston Churchill As an aspiring architect, I always seek the value of architecture creation beyond its physical manifestation. In my younger years, my ambition has always been “to contribute for the betterment of society”. It is not until later that I learnt through the writing of a Malaysian architectural academician that architecture has the potential as an agent of change for nation-building; figuratively and literally. Within this portfolio is a selection of professional works acquired during my experience as an Architectural Graduate at BLP, Architectural Graduate at Hayball, Melbourne and as an Architectural Student at Skematics Architects, Melbourne. Along with the work samples are descriptions of my involvement in the specified projects. I seek with great anticipation the next opportunity to working within a new practice as a stepping stone for me apply and expand my architectural knowledge, as well as to grow as an individual along with the growth of the practice.
skills. Revit | Expert AutoCAD | Competent dRofus | Basic Adobe Creative Suite | Competent Microsoft Office suite | Basic
contents. Northern Private Hospital, VIC | Healthcare Involvement period: March 2021 - June 2022 Latrobe Regional Hospital Stage 3A, VIC | Healthcare Involvement period: April 2020 - February 2021 Campbelltown Hospital Refurbishment, NSW | Healthcare Involvement period: 2019 - March 2020 Jordan Springs Primary School, NSW | Education Involvement period: September - December 2018 Western Sydney Wollongong Schools, NSW | Education Involvement period: August - September 2018 St John’s Primary School, Frankston East | Education Involvement period: July - September 2018 2-4 Bruce St, Box Hill | Multi-residential Development Involvement period: June 2018 Braemar College Woodend - Stage 1 | Education Involvement period: May 2018 Minaret College, Springvale | Education Involvement period: May 2018
WORK EXPERIENCES Architectural Graduate at BLP
11610
Involvement: Key person in document-
review Department: IPU, Operating Theatres,
MEEX-008
GLAZING TO CONTROL ROOM
ITCL-023 ITCL-020
MGFP-001 MGFP-007 MMGE-138
ITCL-012
MMGE-048
GPOE/2 GPOE/2
MMGE-142 MMOP-076 MMOP-076 MMOP-069
MMOP-069
MMOP-028
GPOE/2-1000
MMOP-086
MMOP-028
MMGE-045 MMGE-045
2400 BENCH LENGTH
MMGE-079
CEILING EQUIPMENT CLEARANCE ZONE
DOOR LEAF 920/920
MMGE-123
MMGE-123
MMSP-034.1
OPS-04-04 ANAESTHETIC BAY AA51-3141-1
MMSP-034.3
6xRCDs
EPJ-1000 UPSI-1000
ITAV-057
MMOP-040 MMSP-037 MMOP-071
MMOP-071
MMSP-037 MMSP-029
MMGE-014
GPO/C-600 LSP-1000 EC-1650 SNA-1200
MMSP-029 MMMI-388
MMOP-052
DOOR LEAF 920/920
FIRT-044
OPS-32-04 EXIT BAY AA51-3142-1
MMSP-033
MMSP-033
GPO/C-600
CONTRASTING COLOUR STERILE ZONE (4.0M X 3.4M)
WRITE-UP BENCH BY SUPPLIER (STRYKER)
MMOP-101 MMOP-100
ITAV-057 MMGE-087
1000
1
GPOE/2-900 GPOE/2-900
WPT GPO/2-1100
HDMI
OPS-59-05 SET-UP AA51-3143-1
PLAN
1 : 50 ref: AA14-0101
DRAWING NUMBERS ARE UPDATED TO REFLECT THE RELEVANT DEPARTMENT CODE: EXAMPLE: PREVIOUS DRAWING NUMBER: AA51-0101 UPDATED DRAWING NUMBER: AA51-X101 WHERE X REPRESENTS THE DEPARTMENT CODE. REFER TO AA00-0002 FOR THE DEPARTMENT CODE LEGEND.
ROOM LAYOUT SHEET - FOR CONSTRUCTION
ITCL-012
GPO-E/2-1600 GPO-E/2-1600
MMMI-387
MMSP-034.2
CIRCULATION ZONE
P1
TSP-1000
CONTRASTING COLOUR STERILE ZONE SHOWN INDICATIVE ONLY TBC BY EQUIPMENT SUPPLIER & CLIENT
CIRCULATION ZONE
FQDW-044
GPOE/2-900 GPOE/2-500
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
MMGE-123
FIJO-548
CSSD, Day Oncology, Mental Health IPU
4
FQSM-039
ITNE-007
HATCH AREA DEMARCATES NO OBSTRUCTION ZONE. PROVIDE A LINE MARKING & ADD SIGN ON FLOOR: DO NOT OBSTRUCT GRILLE AIRWAY
relating to Clinical Planning, Shop drawing
ITCL-023 MMOP-043
ITNE-053 MMGE-152
LSP-1000 ITSE-049 DATA/1-1000
FIDI-031 FIDI-001 FIDI-014
ITCL-020
9030
Sheet, FFE Plan, Services coordination
MMMI-377
DATA/1-1350
ITSE-038
ing fit-out documentation; Room Layout
GPOE/2-1200 GPO-E/2-1600
MEEX-008
DATA/2-1200 GPOE/2-1200
DOOR LEAF 920
Project: Northern Private Hospital, Epping
OPS-62-01 CONTROL AA51-3114-1
2
1a
4
AA51-3102-3 AA51-3102-3
DATA/2-1600
3
MMSP-034.1
MMGE-123
ELPR-003 DATA/2-1000 ELPR-003
AA51-3102-4 MMGE-123
RE-08
DOOR LEAF 920
MEEX-008
MEEX-008
FIJO-841
FIJO-220
FIJO-841
FIJO-220
FIJO-841
FIJO-220
CATHETER HANGING HOOKS SHOWN ARE INDICATE ONLY. CLIENT TO SPECIFY. APPLICABLE TO ALL FIJO-220.
Excerpt from architectural drawing set / Revit FINISHES
- FULL HEIGHT WALL VINYL TO WALLS - VINYL FINISH TO FLOOR WITH CONTRASTING COL FLOOR INSET TO CENTRE
Excerpt from architectural rendering set / Revit, Lumion 5
C:\Users\nikki\Documents\AA99-0201_18042_NPH_A20_FFE_nikkiNU8WG.rvt
KEY PLAN
3
Zone A
FISJ-114
OPS-01-01 OPERATING ROOM AA51-3281-1
OPS-20-01 STAFF ROOM AA51-3110-1
REFER ROOM OPS-05-04 FOR TYPICAL FFE & SETOUT DIMS. U.N.O.
OPS-52-01 SCOPE REPROCESSING DIRTY AA51-3306-1
OPS-05-11 REC BAY ST1 AA51-3104-1(S)
2650
2650
2650
GENERAL NOTES: • CONTRACTOR SHALL VERIFY ALL DIMENSIONS OF THIS DRAWING AND SITE CONDITIONS PRIOR TO ANY WORK COMMENCING. • ALL DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE. • ALL DIMENSIONS ARE TO THE FINISH FACE OF THE WALL UNLESS NOTED OTHERWISE. • ALL DIMENSIONS SHALL BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK. RELEVANT PARTY SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES. • THE MANUFACTURER SHALL NOT COMMENCE ANY WORKS PRIOR TO RETURN OF APPROVED SHOP DRAWINGS SIGNED BY THE RELEVANT CONSULTANTS. • THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS, SPECIFICATIONS, REPORTS AND DRAWINGS. • ALL AA14 SERIES DRAWINGS ARE TO BE READ IN CONJUNCTION WITH JOINERY / SANITARY KIT OF PARTS & LINE OF HEIGHTS DRAWINGS. • REFER TO A15 SERIES FOR FLOOR FINISHES, WALL FINISHES, SKIRTING TYPE AND FEATURE FINISHES. • REFER TO WALL SETOUT DRAWINGS FOR WALL TYPES. • REFER TO INTERNAL GLAZED SCHEDULES FOR INTERNAL WINDOW TYPE/SIZES. • FFE ITEMS SHOWN IN THIS DRAWING ARE INDICATIVE ONLY, SHOWN FOR PLANNING PURPOSES AND SERVICES COORDINATION ONLY, REFER ALSO TO DOCUMENTS OF FF&E CONSULTANT AND RELEVANT SCHEDULES. • AV EQUIPMENT & ASSOCIATED SERVICES ARE INDICATIVE ONLY, SUBJECT TO CLIENT BRIEF. • GPO AND DATA POINTS LOCATIONS INDICATED ON ELEVATIONS AND PLANS. REFER TO ELEVTRICAL AND SERVICES DRAWINGS FOR DETAILS AND SPECIFICATIONS.
2650
P1
2650
AA61-0501
REFER ROOM OPS-05-04 FOR TYPICAL FFE & SETOUT DIMS. U.N.O.
REFER ROOM OPS-05-04 FOR TYPICAL FFE & SETOUT DIMS. U.N.O.
OPS-05-01 REC BAY ST1 AA51-3104-1(S)
RECOVERY BAY BEDHEAD JOINERY
REFER ROOM OPS-05-04 FOR TYPICAL FFE & SETOUT DIMS. U.N.O.
OPS-05-02 REC BAY ST1 AA51-3104-1(S)
REFER ROOM OPS-05-04 FOR TYPICAL FFE & SETOUT DIMS. U.N.O.
REFER ROOM OPS-05-04 FOR TYPICAL FFE & SETOUT DIMS. U.N.O.
OPS-05-05 REC BAY ST1 AA51-3104-1(S)
OPS-05-06 REC BAY ST1 AA51-3104-1(S)
OPS-05-04 REC BAY ST1 AA51-3104-1
OPS-05-03 REC BAY ST1 AA51-3104-1(S)
REFER ROOM OPS-05-04 FOR TYPICAL FFE & SETOUT DIMS. U.N.O.
REFER ROOM OPS-05-04 FOR TYPICAL FFE & SETOUT DIMS. U.N.O.
OPS-05-07 REC BAY ST1 AA51-3104-1(S)
OPS-05-08 REC BAY ST1 AA51-3104-1(S)
TV-01-01 STAIR 1
KICTHENETTE JOINERY
OPS-28-01 BAY HWB-A AA51-3222-1
FIJO-548
FISJ-114
THERMOSTAT
P1 AA61-0403
OPS-52-02 SCOPE REPROCESSING CLEAN AA51-3306-1
ITSE-038
P4
30
AA61-0102
ITSE-038
ITSE-001
OPS-10-01 WC-ST AA52-0103
THERMOSTAT
OPS-CIRC-04 OPS-27-02 CIRC. BAY LIN -
OPS-51-01 SCRUB UP AA51-3162-1
OPS-04-01 ANAESTHETIC BAY AA51-3285-1
OPS-32-01 EXIT BAY AA51-3162-1
OPS-09-02 ST-EQUIP AA51-3153-1
OPS-CIRC-02 CIRC. AA50-0101
OPS-28-02 BAY HWB-A AA51-3222-1(S)
OPS-05-09 REC BAY ST1 AA51-3104-1(S)
OPS-59-01 SET-UP AA51-3305-1
REFER ROOM OPS-05-04 FOR TYPICAL FFE & SETOUT DIMS. U.N.O.
GPO/C-600
OPS-15-01 MEETING ROOM AA51-3110-1
P2
OPS-10-02 WC-ST AA52-0103
OPS-05-10 REC BAY ST1 AA51-3104-1(S)
OPS-CIRC-05 CIRC. AA50-0102
STAFF STATION JOINERY
AA61-0203
GPO/C-600
DRAWINGS TO BE READ IN CONJUNCTION WITH AA06* SERIES; PRECINCT PLANS AA12* SERIES; WALL SETOUT PLANS AA13* SERIES; REFLECTED CEILING/SOFFIT PLANS AA15* SERIES; FINISHES PLANS AA50* SERIES; INTERNAL ELEVATIONS AA51* SERIES; ROOM LAYOUT SHEETS AA52* SERIES; WET AREA PLANS, ELEVATIONS AA60* SERIES; KIT OF PARTS - JOINERY AA61* SERIES; SPECIAL JOINERY AA70* SERIES; WALL TYPE, PARTITIONS AND CEILING GENERAL DETAILS AA71* SERIES; KIT OF PARTS - SERVICES LINE OF HEIGHTS AA80* SERIES; SANITARYWARE SET AA82* SERIES; INTERNAL GLAZING TYPES & DETAILS AA83* SERIES; DOOR TYPE ELEVATIONS & DETAILS AA96-0004; MATERIAL SCHEDULE AA96-0005; FURNITURE, FITTING & EQUIPMENT SCHEDULE
FISJ-213
OPS-25-03 BAY MEQ AA51-3161-1
GPOE/2-1000
FHR
BANQUETTE SEATING JOINERY
OPS-CIRC-05 CIRC. AA50-0101
450
FISJ-114
2650
FIJO-548
1325
STAFF BANQUETTE SEAT JOINERY UNDER REVIEW.
FIDI-014 2485
1155
FIBM-019 9090
FIDI-014
AA14 SERIES - FURNITURE, FITTINGS & EQUIPMENT (FFE) NOTES
OPS-24-02 BAY RES AA51-3232-1(S)
OPS-09-15 ST-EQUIP AA51-3156-1
REFER ROOM OPS-05-04 FOR TYPICAL FFE & SETOUT DIMS. U.N.O.
OPS-12-01 STAFF STATION AA51-3249-1
EQ
OPS-40-01 RECEPTION AA51-3249-1
OPS-11-02 CLEAN UTILITY AA51-3157-1
OPS-25-04 BAY MEQ AA51-3161-1(S)
EQ
OPS-05-12 PAT. BAY HOLD AA51-3247-1
EQ
P3
EQ
OPS-05-13 PAT. BAY HOLD AA51-3150-1
AA61-0501
BEDHEAD JOINERY
GPO/2-1000
P3 AA61-0501
BEDHEAD JOINERY
FFE TAGS LEGEND
FISJ-212
OPS-CIRC-08 CIRC. AA50-0102 ITSE-001 ITSE-024
ITSE-038
OPS-23-01 CLNR AA51-3160-1
EN-01-06 ELEC -
GPO/C-600
GPO/C-600
EQ
OPS-27-03 BAY LIN AA51-5222-1
OPS-01-04 HYBRID THEATRE AA51-3102-1 FIBM-019 9060
MMSP-034.3
OPS-32-02 EXIT BAY AA51-3284-1
MMOP-040
10020
MMOP-052
OPS-09-08 BAY - BLOOD FR. AA51-3261-1
OPS-68-01 COMPUTER -
OPS-CIRC-07 CIRC. AA50-0101
OPS-51-04 SCRUB UP AA51-3142-1
1930
OPS-51-05 LAB SCRUB AA51-3117-1
OPS-59-05 SET-UP AA51-3143-1
GPO/2-1100 DATA/2-1100
GPO/C-600
REFER AA50 DRAWING SERIES FOR INTERNAL ELEVATIONS
TV-01-06 PATIENT LIFT LOBBY AA50-0103
790
EN-01-04 KIT. RISER
TV-00-05 LIFTS SHAFT -
OPS-32-05 PATH. COLLE. AA51-3252-1
TV-00-05 LIFTS SHAFT -
FOR CONSTRUCTION ALL ROOM LAYOUT SHEET REFERENCES UPDATED C2 FOR CONSTRUCTION C1 FOR CONSTRUCTION B FOR BUILDING PERMIT A MILESTONE FOR INFORMATION REV AMENDMENTS
2091
OPS-09-04 ST-STERILE STOCK AA51-3116-1
GPO/2-1100 DATA/2-1100
OPS-06-02 DISPOSAL AA51-3244-1
1772
ITSE-038
OPS-62-03 LAB CONTROL AA51-3111-1
GPO/C-600
DB OPS-62-02 LAB REPORT AA51-3111-1
OPS-04-03 ANAESTHETIC BAY AA51-3103-1
21/12/2021 27/08/2021 02/07/2021 04/06/2021 DATE
THERMOSTAT PANEL
TV-01-05 TRAVEL AA50-0103
Billard Leece Partnership
T +61 3 9656 5000 E info@blp.com.au www.blp.com.au
CLIENT
RAMSAY HEALTH CARE AUSTRALIA
OPS-25-06 BAY BED AA51-3264-1
OPS-09-06 ST-EQUIP AA51-3155-1
PROJECT NAME
NORTHERN PRIVATE HOSPITAL SHEET NAME
PLAN - FFE - LEVEL 1 ZONE A
365
OPS-35-01 WRITE-UP
480
495
470
460
31/05/2022 25/01/2022
Level 20/485 LaTrobe Street Melbourne 3000 Victoria, Australia
OPS-01-05 CATH LAB AA51-3105-1
GPO/C-600
435
REFER AA52 DRAWING SERIES FOR DETAIL PLAN & INTERNAL ELEVATIONS
C4 C3
OPS-35-02 WRITE-UP
OPS-32-03 EXIT BAY AA51-3107-1
REFER AA51 DRAWING SERIES FOR DETAIL PLAN & INTERNAL ELEVATIONS
CSD-CIRC-01 LIFT-DIRTY
GPO/2-800 DATA/2-800
OPS-01-03 OPERATING ROOM AA51-3101-1
GPO/C-600 FQSN-082
FIJO-540
GPO/2-1000
OPS-51-03 SCRUB UP AA51-3107-1
REFER AA51 DRAWING SERIES FOR DETAIL PLAN & INTERNAL ELEVATIONS
REVERSE CLOUD: WORK IN PROGRESS, UNDER REVIEW
OPS-69-01 LAB LEAD APRON AA51-3117-1
OPS-25-01 BAY MEQ GPO/2-1000
ROOM NUMBER ROOM NAME ROOM LAYOUT SHEET REFERENCE '(S)' DENOTES SIMILAR FFE LAYOUT '(M)' DENOTES MIRRORED FFE LAYOUT
SHADED REGION NOT PART OF STAGE 1 SCOPE OF WORK
450
MMGE-139
645
DASHED LINES INDICATES FIXED JOINERY ABOVE OR BELOW
IP1-00-00 1 BED AA51-0000-1
ITSE-024 ITSE-038
THERMOSTAT
OPS-CIRC-03 CIRC. AA50-0101
FFE CODE - REFER TO AA14-0000 FFE SCHEDULE & AA96-0005 FOR DETAILS
ROOM TAG LEGEND
EN-01-02 COMMS -
1000 CIRCULATION ZONE
MMSP-034.2
SPECIAL JOINERY CODE - REFER AA61 SERIES FOR DETAILS
FQTA-000
OPS-06-01 CLEAN-UP ROOM AA51-3243-1
2188
FIBM-006 3512
OPS-09-03 STORE AA51-3154-1 OPS-59-02 SET-UP AA51-3106-1
100
E. RISER ROOM
TYPICAL JOINERY CODE - REFER AA60 SERIES FOR DETAILS
FISJ-000
LEGEND
ITSE-001 ITSE-024 ITSE-038
MMMI-387 MMSP-033
EQ
SANITARYWARE/HYDRAULIC FIXTURE ASSEMBLY CODE - REFER AA80 SERIES FOR DETAILS
FIJO-000
OPS-66-01 BAY BLANKET WRMR AA51-3252-1
MMSP-029
OPS-32-04 EXIT BAY AA51-3142-1
OPS-05-16 PAT. BAY HOLD AA51-3247-1(S)
EQ
SERVICES RISER
OPS-09-05 ST-GEN AA51-3144-1
OPS-27-04 BAY LIN AA51-3252-1
OPS-51-02 SCRUB UP AA51-3284-1
EQ
OPS-CIRC-09 CIRC. AA50-0103
0
OPS-04-04 ANAESTHETIC BAY AA51-3141-1
OPS-01-02 OPERATING ROOM AA51-3282-1
OPS-05-15 PAT. BAY HOLD AA51-3247-1(S)
OPS-10-03 WC-ACC AA52-0103
SHW-000 SNK-000 HWA-000 WCF-000
345
NOMINATED ARCHITECT:
DRAWN BY
N
DS / JFS REGISTRATION NO.
CHECKED BY
SG PROJECT NO.
REVISION DATE
18042 DRAWING NO
SCALE
31/05/2022
[C4]
FOR CONSTRUCTION
PRINTED:31/05/2022 5:09:32 PM
AA14-0101
1:50@A0 REVISION NUMBER
FILE NAME: 18042-AA14-0101- PLAN - FFE - LEVEL 1 ZONE A- [C4]
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
OPS-68-02 LAB COMP EQUIP
OPS-04-02 ANAESTHETIC BAY AA51-3283-1
MMGE-014
6
EN-01-03 DB
OPS-62-01 CONTROL AA51-3114-1
OPS-11-01 MEDS AA51-3246-1
EN-01-05 THEATRES AV & IT COMMS -
OPS-28-07 BAY HWB-B AA51-3222-1(S)
GPO/C-600
MOVE INSIDE THE BIG BOX
THEATRE RECEPTION JOINERY
CONTINUE ON SHEET AA14-0102
GPO/C-600
P1 AA61-0203
OPS-CIRC-01 CIRC. AA50-0101
OPS-CIRC-01 CIRC. AA50-0101
THERMOSTAT
ITSE-038
2375
OPS-09-01 ST-GEN AA51-3152-1
GPO/C-600
GPO/C-600
GPO/C-600
ITSE-038
Excerpt from architectural drawing set / Revit
815
1865
900
C:\Users\dianm\Documents\AA99-0201_18042_NPH_A20_FFE_dian.s.rvt
1920
300
2700.0 FCL WL-05
DATA/2-1600 GPO-E/2-1600
1400.0 .
WL-05
WL-05
DATA/2-1600 GPO-E/2-1600
DATA/2-1600 GPO/2-1600
1000.0 .
WL-05
GPO/2-1600 DATA/2-1600 GPO/2-1200 DATA/2-1200
MMIC-039
MMIC-039
1200.0 .
MMIC-028
1650.0 .
MMIC-028
WL-05
LSW-1000
FIJO-503 HYBA-043
FIDI-009
SK-02
SK-02
GPOE/1-600
SK-02
ELEVATION
2
1 : 50
2700.0 FCL WL-05
FQSM-015
FQSM-015
ELEVATION 1 : 50
WL-05
FUTURE PASS THROUGH WASHER
FQSM-015
INTERNAL GLAZING
INTERNAL GLAZING
1400.0 . DIRTY LIFT
150.0 . 0.0 FFL
3
ITSE-038 LSW-1000
HWC-04
1700
1000.0 . 600.0 .
SK-02
1 : 50
EXAMPLE: PREVIOUS DRAWING NUMBER: AA51-0101 UPDATED DRAWING NUMBER: AA51-X101 WHERE X REPRESENTS THE DEPARTMENT CODE. REFER TO AA00-0002 FOR THE DEPARTMENT CODE LEGEND.
ROOM LAYOUT SHEET - FOR CONSTRUCTION
PASS THROUGH WASHER
MEDICAL DRYER PASS THROUGH
MMIC-005
MMGE-113
MMIC-100
4
815
3430
750
WALL OPENING WIDTH
WALL OPENING WIDTH
WALL OPENING WIDTH
MMIC-100
ELEVATION 1 : 50
TAG LEGEND
Excerpt from architectural drawing set / Revit XX-00
REFER AA15* SERIES & AA96-0002 MATERIAL SCHEDULE FOR FINISHES DETAILS
FISJ-000
REFERS TO SPECIAL JOINERY. REFER TO CALL-OUT IN FLOOR PLAN FOR DRAWING REFERENCE
FIJO-000
REFER AA60* SERIES FOR TYPICAL JOINERY DETAILS
HW*-00 SHW-00
SNK-00 WCF-00
REFER AA80* SERIES FOR SANITARYWARE ASSEMBLY & SETOUT DETAILS
7
FILE NAME: 18042-AA51-4301-3- CSSD - CLEANING/ DECONTAMINATION - E
DRAWING NUMBERS ARE UPDATED TO REFLECT THE RELEVANT DEPARTMENT CODE:
PASS THROUGH HATCH MMIC-011
PASS THROUGH WASHER
SK-02 MMGE-113
ELEVATION
SK-02
45
WL-05
WL-05
1650.0 . 1200.0 .
SK-02
2700
FQCW-006
1000
1
FQSM-015
GPO/C-600
2440
150.0 . 0.0 FFL
GPO/C-600
GPOE/1-600
2000
FIJO-522
WALL OPENING HEIGHT
MMIC-100
WALL OPENING HEIGHT
600.0 .
HYBA-043
WALL OPENING HEIGHT
MMGE-113
Project: Latrobe Regional Hospital Stage 3A, Traralgon Involvement: Key person in clinical planning documentation, user group presentation, fit-out documentation and coordination, services coordination C:\Users\felicia\Documents\19073-BLP-ARC-RVT-LRH_R19_FITOUT_felicia9LANP.rvt
relating to clincal planning and FFE
KEY PLAN
Department: ICU, Operating Theatres, CSSD, Paediatric, Maternity, Special Care Nursery, IPU B1
B2
ZONE A
B3
HVB-01
8700
8400
B4
1100 ELGP-208
LIFX-016
ELBO-015
ST EQ 03-045 A51-03-045
CONTINUED ON SHEET:A14-0121
FQBS-018 ITNE-049 FQSM-007
FQSN-031
1100
FQSN-096
ZONE D
HVB-01 HWB-01
ITNE-007
600 600 600
FIJO-099
FQDW-032
ELGP-208 ELGP-208 ITIN-026
REFER TO 03-015 & 03-022 FOR TYPICAL ROOM FF&E AND TYPICAL SET-OUT DIMENSIONS U.N.O.
B2
ZONE C
8400 HVB-01
ZONE B
B5
8400
JSA3-A
REFER TO 01-049 & 01-034 FOR TYPICAL ROOM FF&E AND TYPICAL SET-OUT DIMENSIONS U.N.O.
677
FQSN-096
FQSN-096
ZONE E
FISJ-052.1
HVB-01 JCR1-A
1100
1100
ITIN-026 1100 ELGP-208 1100
600
EQ
RPZD-01
ELGP-208
ELGP-208
1600
EQ
1600
REFER TO 01-047 & 01-035 FOR TYPICAL ROOM FF&E AND TYPICAL SET-OUT DIMENSIONS U.N.O.
HVB-01
1700
HYDR-004
500
B-WU-EMR 03-173 A51-01-095
HVB-01
HWB-05L
4
1
JBH1 JCA3-6G
ITNE-052
ITIN-016
MMMA-015
MMBE-005
FIHR-016 FQCW-044.1
2
3
6.
ITIN-016
ITNE-052
FIDI-001 FIDI-001 ITIN-026
800
600 600 600
600 600 600
600 600 600
ELGP-208 ELGP-208 ITIN-026
ELGP-208 ELGP-208 ITIN-026
JSA5-B
600
600
ITIN-026
ELGP-208
1100 600 600 600 ELGP-208 ELGP-208 ITIN-026
FQBS-018
ITNE-007
FQBS-018
ITNE-007 ITNE-007
3
2
ITNE-049 ITIN-026 ELGP-208 ELGP-208
A51-03-041-1 ITCL-026
600 600 600
FIHR-026
ITIN-026 ELGP-208
ITNE-007
ITNE-007
FQBS-018 FQSM-007 ITNE-049
1100 1100
ELBO-015
FQGE-056 ITSE-006
600
600 600 600
1100
ITNE-007
600 600 600
ELBO-015
MMBE-056
WCF-04L FIBM-019.2
B7
FQBS-017
FQSN-031
ELGP-110
FQSN-031
B6
600
FISJ-100.1
600
900
600 ELGP-208
CIRCULATION MAT-BIRTH-CIRC-02-2
ELGP-208
1100 1100 1100
FQBS-026
CIRCULATION MAT-BIRTH-CIRC-03
CIRCULATION MAT-BIRTH-CIRC-01-2
FQTA-053
1
2
JBU9-E FQCW-018 1100
FQBS-017 1400 1400 1400 1400
ITIN-036 ELGP-208 ELGP-208
1400 1400 1400
FQBS-017
HVB-01
FQSN-050 FIRT-032
x3
FIHR-026 FIHR-026
SHW/WC ACC 03-165 A52-0013
1100
BENL-75B ITNE-023 FIJO-099
FQBS-018
ELGP-109 ITIN-026 ELGP-208 ELGP-208
ELGP-110
600 600
600
600
FQBS-009
1100
FIHR-026 FQBS-030 FIBM-006.2
ELGP-208
1100
BI
FQBS-009
ELGP-208
600
FQBS-035
HWC-02L
Billard Leece Partnership
FQBS-510 FQBS-010
ELGP-208
MMBE-045 FQBS-030
FQBS-009
600
FQTA-055
FISJ-085
24/06/2022 07/06/2022 23/07/2021 DATE
Level 20/485 LaTrobe Street Melbourne 3000 Victoria, Australia
FQBS-510
BC-03
MMBE-045
MMGE-091 LIFX-016
C3 FOR CONSTRUCTION C2 FOR CONSTRUCTION C1 FOR CONSTRUCTION REV AMENDMENTS
BC-03
SNK-05
WL-05 750-1700AFFL
SHW-01L
600 1100
FQBS-009
FISJ-027
600 600
ITIN-026
ELGP-208 ITIN-016
600 600
JSA5-B
1100
ELBO-015
1100
FQGE-009 CONTINUED ON SHEET:A14-0141 ITNE-049
1635
LIFX-013
ITBU-011 (65") FIHR-006
FQBS-009 FQTA-043
ELGP-209 ELGP-208
200
HWB-01 WCF-01R
FQSN-050
A51-03-018-2
ITSE-006
300
FQSN-050
HVB-01 HWC-02L
FIHR-026
HVB-01
1200 1200 1200
FQBS-009
FQBS-009
3 A51-03-050-2
ITNE-052
ITIN-026
ITNE-007
FQSN-050 FQSN-050
FIDI-001
600
600
340
JCA3-6F
ELGP-208
FIBM-019.4 FQSN-050
FIHR-026
600
ITIN-026 ELGP-208 ELGP-208
LT-04
ITAV-051 (75") FIHR-006 ITNE-004
FQTA-086
FQBS-017
600
ITIN-026 ITIN-026 ELGP-208 ELGP-208
FQBS-017 FQTA-086
FQBS-017
1100 1600 1400
ELGP-109
F F F
ITIN-143 ITNE-010
FQBS-017
ELGP-110
ELGP-203 ELGP-203 ITIN-022
FQTA-086
A51-03-050-2
ITCL-006 ITCL-004 ITCL-008
FQBS-017
FQBS-017
2
JCU2-9L2
FQBS-017
ITNE-060
FQTA-086
FQBS-017
1100
ELGP-208
FQSN-050
FIHR-026
FQSN-050
ITIN-016
ANTE 03-166 A51-01-016 (S)
FIHR-026
300
4 FQBS-001
FQBS-017
FQBS-017
ITNE-060
ITIN-145
FQTA-086
FQBS-017
FQBS-017
ITNE-052
MMGE-048 MMGE-137 FIHR-026
ELGP-110
FQTA-013
F F F
ITIN-143
FQTA-086
HWA-04
FQTA-053
ELGP-203 ELGP-203 ITIN-022
FQBS-017
FQBS-017
FQBS-017
1
BENL-45A
FQBS-017
FQBS-017
ITNE-013
1200
FQBS-017
MMOP-060
1100
ITIN-016
FQBS-017
JCU2-9L2
1200 1200 1200 1200
ELGP-109
FQSN-050
C
600
1100
1225
ELGP-208 ELGP-208 ITIN-026 ITIN-026
FQBS-017
ELGP-208
600
1200
HWB-01
JCA3-8B JCA6-8
BC-04
ITNE-010
AV SCREEN CENTER TO WALL
ELGP-223
FQBS-017
ITAV-051 (65") FIHR-006 ITCL-014 ELGP-109 2400
HYDR-004 600
MSP-PB4
FISJ-026
2400
ELPR-011
FIHR-006 ITBU-012 (50")
ELGP-110
1450 1450 1450 ELGP-208 ITIN-070 ITIN-016
600
FQBS-017
FIDI-030
FQCW-044.1 FIHR-016
600
FQTA-055
4
690
1945
ELGP-208
SHW-03L ITCL-037
LT-06
FQBS-030
BH
FIRT-034 FQGE-011
1100
FIBM-026 ITCL-014
2
HYDR-004 HYBA-022 HYTP-048
FISJ-062
JSR1-A ELGP-208
1600 FIRT-016 1400
HVB-01
FQTA-053
FQBS-041
FQBS-026
MMMA-014
1190 FIDI-025 FQCW-018
900 ITCL-004 ITCL-008
BC-05
FQBS-041
FQBS-026
ITBU-025
1200
4000
FIHR-026 FIHR-026
600
MSP-PB4
ENS-BIRTH 03-023 A51-03-024
ITBU-025
ELGP-223
A51-03-024-1
ELGP-101
ITCL-037
SHW-03L
HYDR-004
1810
3
REDUCED PRESSURE ZONE DEVICE BOX REFER TO HYDRAULIC DOCUMENTS FOR DETAIL, AT 1500MM AFFL TYPICAL. BLUE ARROW INDICATES THE SIDE OF ACCESS PANEL IS FACING.
FQBS-026
ELGP-208
HVB-01
FQSN-050
FIRT-016 HYDR-004
FISJ-062
HYBA-022 HYTP-048
600
4
ENS-BIRTH 03-024 A51-03-024
MMMA-014
ELGP-109
LT-06 FIDI-025
1100
FIDI-030
JSR1-A
ELGP-208
FQGE-011 FIRT-034
HYDRAULIC VALVE BOX REFER TO HYDRAULIC DOCUMENTS FOR DETAIL, AT 300MM AFFL TYPICAL UNLESS NOTED OTHERWISE. BLUE ARROW INDICATES THE SIDE OF ACCESS PANEL IS FACING.
RPZD-01
600
WCF-01R
1
ROOM LAYOUT SHEET REFERENCE, REFER TO RLS FOR ROOM ELEVATIONS
HWB-05L
UB
FE-01 FIHR-026 FIHR-026
INTERNAL ELEVATION MARKER, REFER TO ROOM LAYOUT SHEET FOR DETAILS, REFER TO A51-SERIES
HVB-01
SHW-02R
FIRT-039
ITCL-008 1400 1600
FF&E CODE - SPECIAL JOINERY, REFER TO A61-0000 FOR JOINERY DRAWINGS
1
MMMA-015
FQSN-050
1600
1100 ELBO-015
ITIN-010
ITCL-033
1600
2400
ITCL-004
ITCL-014
ELGP-109
ITIN-016 1450 ITIN-070 1450 ELGP-109 1450
FIHR-006 ITBU-012 (50")
EQ
FIBM-026
ITCL-008 ITCL-004
1
A51-0X-XXX
1350
FIHR-026
FQTA-055
FQBS-022
MSP-PA1-VL
MSP-SA1-VR
MSP-SA1-VL
1
ITNE-049
1
FQBS-018
FQSM-007 FQBS-018
600 600 600
1100 1100 ELGP-208 ELGP-208 ITIN-026
FISJ-213
1100
FIHR-026
ELGP-208 ELGP-208 ITIN-026
1
ELBO-015
FQCW-018
FQSM-007
FQCW-018
FQCW-018
FF&E CODE, REFERS TO EQUIPMENT UNITS, REFER TO KIT OF PARTS DRAWINGS A71-SERIES & A80-SERIES
NO WINDOW JOINERY
JSA3-A
ELBO-015 ELBO-015
4
ITNE-007 ITNE-049
FQDW-032
FQBS-017
FQBS-017
FF&E CODE, REFER TO A60 TYPICAL JOINERY DRAWING SERIES FOR DETAILS
FISJ-###
HVB-01
FIBM-019.2
FF&E CODE, REFER TO A14-0000 FF&E SCHEDULE FOR DESCRIPTION
JCAX-01
FISJ-022.1
REFER TO 03-068 & 03-087 FOR TYPICAL ROOM FF&E AND SET-OUT DIMENSIONS
FQTA-057
1100
ITNE-007
FIHR-000
HWB-02R
JSA5-B
JBH1
FISJ-022.1
JCR1-A
ITNE-007
JSA5-B
LIFX-016
REFER TO 03-069 & 03-082 FOR TYPICAL ROOM FF&E AND SET-OUT DIMENSIONS
1100 1100
1100
600 600 600
FQBS-018
ITNE-007
JSA5-B
FQBS-018
1100
FF&E CODE - SERVICES MOUNTING HEIGHT 'C' FOR CEILING MOUNTED 'F' FOR FLOORBOX 'UB' FOR UNDER BENCH MOUNTED NOTE: REFER TO SERVICES DRAWINGS FOR DETAILS
ELGP-208.2 1100
ELGP-208 ELGP-208 ITIN-026
600 600 600
BENL-60B
ELGP-208 ELGP-208 ITIN-026
MGFP-001 ELGP-208
FF&E TAGS NO WINDOW JOINERY
HVB-01
ELBO-015
ITNE-007
ELGP-208 ELGP-208 ITIN-026
FQBS-018
ITNE-007
FIHR-084
600 600 600
NOTE: DASHED LINES TYPICAL INDICATE LOOSE FF&E OR FIXTURES ABOVE
MMBE-056
ELBO-015
600 600 600
600 600 600 ELGP-208 ELGP-208 ITIN-026
FQBS-018
FQBS-018 ITNE-007
ROOM NAME ROOM NUMBER ROOM LAYOUT SHEET REFERENCE
ROOM NAME 01-001 A51-01-001
NOTE: - (M) REFERS TO MIRRORED SET-UP TO ROOM LAYOUT SHEET - (S) REFERS TO SIMILAR SET-UP TO ROOM LAYOUT SHEET
MSP-PA1-VR
800
FISJ-100.1
WCF-04R
FIBM-019.2
MSP-SA1-VL
ELGP-208
MSP-PA1-VR
SHW-02R HWB-05R
FQBS-018
ELGP-208 ELGP-208 ITIN-026
FQBS-018
ELGP-208 ELGP-208 ITIN-026 600 600 600 ELGP-208 ELGP-208 ITIN-026
1100
MSP-SA1-VL
1500
MSP-PA1-VR
HVB-01
1300
FIRT-012
EQ
MMBE-061 BC-05
13.
FISJ-100.2
ITCL-026
600 600 600 ELGP-208
ELBO-012 ELBO-012 ELBO-015
FQGE-010 FIHR-016 FQCW-044.1
MMBE-053
1100
FIRT-012
JSA5-B
FQBS-018
600 600 600
BENL-60B
FISJ-100.1
ITCL-006
1600
201
1100
FIDI-001
FQTA-013
4x ELGP-208
ELBO-015 ELBO-015
ELGP-110 ELBO-012
1200
209
1100
JSA5-B
FQBS-018
ELGP-208 ELGP-208 ITIN-026
FQBS-018
FQSN-031
FIDI-001 1300
HVB-01
ELGP-223
600
TYPICAL PER WORKSTATION
FQBS-018
FQBS-001
HWB-05R
ITNE-021
ELGP-208.2 1100
HWA-04
FQTA-053
ITCL-008
11.
MMBE-056.1
MMBE-056.1
MMHA-002
FIRT-012
ELGP-208
4x ELGP-208
FQSN-086
600 600 600
1200 ELGP-208
JSA5-B
FQBS-018
JSA3-A
ELGP-223
MMMA-011
ITNE-052
C
WCF-04L
LIFX-016
MMGE-063
JCA3-6G
ITIN-026
ITIN-026 ELGP-201
4x
ELGP-208
1100 ELGP-208
1100 ELGP-208
FQSN-086
ELGP-208 ELGP-208 ITIN-026
1200 1200 ITIN-026 ELGP-208
EQ EQ
JDU4-9I
JSA5-B
ITBU-013 FIHR-006
1100 1100
ELGP-208 ELGP-208 ITIN-026
229
ELBO-015 ELBO-015
ITIN-026 ELGP-208 ELGP-208
FQSM-016 FQCW-004
LIFX-013
2
ITNE-049
MSP-RN-HR
MSP-SB3-HR
MMMA-015
WCF-01R
10.
FIRT-012
1100 1100 1100
1600
1100
1600
1100
ITCL-033
ITNE-052
ITCL-004
ELBO-012
ITIN-026
1600
MSP-RN-HL
MSP-SB3-HL
FQBS-030
FISJ-025.4
JCU1-9B
1100
1100 ELBO-015
ITCL-008
MMBE-061
4
JBH1
MMGE-092
600
1
ELBO-003
FIHR-019
FQSN-051 ITNE-049
FQSN-086
JSA3-A
ITCL-004
MSP-PB1-VR
LIFX-017
FISJ-025.3MMGE-100 MSP-SB1-VR
ELGP-109
FIHR-019 MMGE-100
3
A51-03-028-1
A51-03-016-2
ITCL-004
LIFX-017
MSP-SB1-VL
MEEX-008
ELGP-109.2 600
MMGE-092
FISJ-025.2
MMMA-015
HVB-01
MMBE-061
BC-05
FQSM-016
PROVIDE SCRIBING PIECE BETWEEN JOINERY
HWA-04
BIRTH - BATH 03-016 A51-03-016
FQBS-001
MSP-PB1-VL
FQCW-004
MMGE-063
FQCW-044.1 FIHR-016
FINAL LOCATION OF CEILING MOUTED GPO TO BE COORDINATED WITH HOIST MANUFACTURER
03-028 A51-03-028
MMGE-119 JBH1
JCA6-8
MMBE-005
HVB-01 B-WEIGH 600
SHW-03L
JCA3-6J
FIBM-026
FQTA-013
1200
LIFX-016
MMGE-090
MMMA-014
ITCL-037
MSP-PB4
ELGP-101.1 C
ELGP-109.2 600
A51-03-022-1
HYDR-004
2
1100
FQSM-045
FIRT-034 FQGE-011
LT-06
LIFX-013
FQSN-051 ITNE-049
3
HYDR-004
FIDI-030
MSP-PB3
ITIN-010
3
MMBE-061
FQTA-053
600
1100
ELGP-208
2
ITCL-014
A51-03-016-2
C
1
FQGE-010 FIRT-032
1
5
ELGP-110
9.
SHW-02R
FIHR-030
4x ELGP-208
A51-03-022-1
5
FISJ-063 600
HYDR-004
FQBS-022
8400
JSR1-A
MMMA-012
FIRT-034 FQGE-011
HVB-01
ITCL-037
ELGP-223
FIHR-030
1100 1100
WCF-01R
4
FIDI-025
ELBO-012 ELBO-012 ELBO-015
1600 1400
FIBM-019.2
MMGE-045
600
BENL-60C JCU2-9B
600
ELGP-208
300 ITCL-004 ITCL-008
MMGE-051
600
1600
ITCL-033
1600
ITCL-037
HYBA-023
BG
8.
12.
FIDI-001
ELGP-208 ELGP-208 ITCL-008
1400 1600
FIRT-016 HYDR-004
2
3
FQBS-051
FIHR-004 ITBU-012
600
FIHR-030
SHW-03L
1
FIRT-016 FIHR-026 FIHR-026
CEILING MOUNTED EXAMINATION LIGHT TO BE COORDINATED WITH CEILING HOIST RAILS
ELGP-110
HVB-01
MMGE-045
ITCL-008 ITCL-004
600
1100 ELGP-201
7.
FISJ-052.1
FQSN-069
REFER TO 01-047 & 01-035 FOR TYPICAL ROOM FF&E AND TYPICAL SET-OUT DIMENSIONS U.N.O.
FQSM-045
A51-03-021-1 WCF-01L
ELGP-208
FQSN-069
1100 1100 1100
MMGE-010
4
600 HYDR-004
FQCW-018
FQSN-069
1100 1100
ELGP-110
ITCL-004
ITCL-014
ELGP-109
ITIN-010
2400 1100
ITCL-008
ELGP-110
ITIN-026 ELGP-208
FIHR-026 FIHR-026
MSP-PB4
FISJ-062.2
JSR1-A
ELGP-208
5.
REFER TO 01-049 & 01-034 FOR TYPICAL ROOM FF&E AND TYPICAL SET-OUT DIMENSIONS U.N.O.
FE-01
LT-06 FIDI-030 FIDI-025
MSP-PA1-VL
MMBE-056.1
HVB-01
A51-03-015-2
C
FIBM-026
BF
ELBO-015 ELBO-015 ELBO-015
MSP-SA1-VR
MMBE-056.1
CIRCULATION MAT-BIRTH-CIRC-02-3
JCR1-A
600
FQBS-022
T +61 3 9656 5000 E info@blp.com.au www.blp.com.au
CLIENT
VHBA
FISJ-029
MMBE-005
HVB-01
ITBU-011 (50")
PROJECT NAME
LATROBE REGIONAL HOSPITAL STAGE 3A SHEET NAME
PLAN - FF&E - LEVEL 1 ZONE B2 (MATERNITY IPU)
Excerpt from architectural drawing set / Revit PROJECT ARCHITECT:
DRAWN BY
NAK
CHECKED BY
IZ
REVISION DATE
19073 DRAWING NO
24/06/2022
A14-0122
SCALE
1 : 50 @ A0 REVISION NUMBER
[C3]
FOR CONSTRUCTION
_LAST ACCESSED: 23/06/2022 5:51:54 PM
8
PROJECT NO.
_DOCUMENT NUMBER: 19073-A14-0122- [C3]
REGISTRATION NO.
N
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
1
4
FIHR-004 ITBU-012
ELGP-201
FQGE-010 FIRT-039
FIDI-001
FQTA-013
3.
FISJ-052.2
MMGE-164 ITNE-008
HVB-01
200 BC-05
ELGP-208
MMMA-015
HWA-04
FQBS-001
LIFX-013
FQTA-053
A51-03-015-2
1100
B-WU-EMR 03-172 A51-01-095
6
5
1200
JCA6-8
FQBS-030
FQSM-016 MMMA-011
MMGE-063
CONTRACTORS AND THEIR ASSOCIATES SHALL VERIFY ALL DIMENSIONS OF THIS DRAWING AND SITE CONDITIONS PRIOR TO ANY WORK COMMENCING. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE. ALL DIMENSIONS ARE TO THE FINISH FACE OF WALL UNLESS NOTED OTHERWISE. ALL DIMENSIONS SHALL BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK. RELEVANT PARTY SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES. THE MANUFACTURER SHALL NOT COMMENCE ANY WORKS PRIOR TO RETURN OF APPROVED SHOP DRAWINGS SIGNED BY THE RELEVANT CONSULTANTS. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS, SPECIFICATIONS, REPORTS AND DRAWINGS. ALL A14 SERIES DRAWINGS ARE TO BE READ IN CONJUNCTION WITH JOINERY DRAWINGS (A60- & A61-SERIES) & KIT OF PARTS DRAWINGS (A71- & A80-SERIES) E.G. SET-OUT DIMENSIONS. REFER TO A15-SERIES FOR FLOOR FINISHES, WALL FINISHES, SKIRTING TYPE AND FEATURE FINISHES. REFER TO WALL SETOUT DRAWINGS (A12SERIES) FOR WALL TYPES AND DOOR NUMBERS. REFER TO INTERNAL GLAZED SCHEDULES FOR INTERNAL WINDOW TYPE/SIZES, REFER TO A82-SERIES. FFE ITEMS SHOWN IN THIS DRAWING ARE INDICATIVE ONLY, SHOWN FOR PLANNING PURPOSES AND SERVICES COORDINATION, REFER ALSO TO DOCUMENTS OF FF&E CONSULTANT AND RELEVANT SCHEDULES IN A96-SERIES. AV EQUIPMENT & ASSOCIATED SERVICES ARE INDICATIVE ONLY, SUBJECT TO ICT BRIEF AND AV CONSULTANT DOCUMENTS. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL SERVICES DRAWINGS AND DOCUMENTS.
2.
FQSN-069
2
3
1100
MMGE-092
MSP-SB1-VR
MSP-PB1-VL
MSP-SB3-HR MMGE-100 FIHR-019
ELGP-109.2 600
8400
FQSN-051 ITNE-049
ELGP-208
FQCW-004
1.
4.
A51-03-033-1
MSP-RN-HL
MSP-RN-HR
FISJ-025.1 LIFX-017
FISJ-100.1
WCF-04L
2500
CIRCULATION MAT-BIRTH-CIRC-01-3
FISJ-100.2
MSP-PA1-VR
1100
ELGP-109.2 600 ITIN-016 600
SHW-02R
MSP-SA1-VL
MMGE-034
JDU3-7A
ITIN-016
1100 ELGP-109
JDU3-7A
ELGP-109 1100 ELGP-109 1100 ELGP-208 1100 ITIN-026 1100
1100
1100
1100
ITIN-026
ELGP-208
JDU3-7A
JSC
ITCL-026 ITCL-026
JSA2-A JDU3-7A BENL-60C
MED 03-033 A51-03-033 FIBM-019.1
MSP-SB1-VL
MSP-PB1-VR
REFER TO 03-016 & 03-021 FOR TYPICAL ROOM FF&E AND TYPICAL SET-OUT DIMENSIONS U.N.O.
GENERAL NOTES: JSC
JSA5-C JCU2-9C
ELGP-109
987
1100
FIHR-016 FQCW-044.1
HVB-01
FISJ-100.2
MMGE-087
JCA4-6B(L) JCU2-9C
FISJ-100.1
MSP-SA1-VL
FIHR-053 FIHR-029
FIHR-029
FQCW-006
HWB-01
MSP-SB3-HL
KEY PLAN HWB-05R
FQCW-006
LIFX-016
HVB-01
MMBE-056.1
SHW-02R
1100
MMBE-061
FISJ-025.2
MMBE-056.1
WCF-04R
FIDI-001
2
3
MMGE-048 MMGE-048 MMGE-048
FIHR-029 FIHR-053
FIHR-053
FIHR-029 FIHR-053
FQCA-027
ELGP-106
ITCL-026 ITCL-026
ELBO-015
LIFX-013
FQCW-006
600
MMMA-015
200
CEILING MOUNTED EXAMINATION LIGHT TO BE COORDINATED WITH CEILING HOIST RAILS
1850
1
4
1100
HWB-01
A51-03-112-2 MMGE-048 MMGE-048 MMGE-048 FQCW-006 ELGP-110
MMBE-061 FINAL LOCATION OF CEILING MOUTED GPO TO BE COORDINATED WITH HOIST MANUFACTURER
1600
HYDR-004
FIDI-001
SNK-02AL
MSP-PA1-VR
1100
JCA3-6J
ELGP-101.1 C
BE
ELGP-208
FIHR-016 FQCW-044.3
ELGP-208
MMIC-095 MMIC-097
ELPR-003
1200
HYTP-008 HYTP-013 HYTP-008
1200 ELGP-106
1630 MMIC-097
ELGP-106
1600 1600 ELGP-106 ELPR-003
1150
MSP-SA1-VR
EQ
MMIC-095
SNK-02AR
1700
EQ
ELGP-208
FIHR-016 FQCW-044.3
500
MSP-PA1-VL
SHW-03L
HYTP-008 HYTP-013
JCA3-6G(W) HWB-01
HVB-01
HVB-01
HVB-01
ELGP-106
EQ
B-MEQ 03-038 A51-01-079 (S)
300
RPZD-01
1100
350
ELGP-208
EQ
FIHR-029
FISJ-063
FISJ-062
1100 1100 1100 1100
FISJ-052.2
925
FQSN-096
ELGP-208 BENL-60C ELGP-208 JSU1-9B ELGP-208 ELGP-208
HYTP-008
WCF-01R
SHW-03L
WCF-01R
ELGP-208
1600
JSA7-4
C:\Users\helend\Documents\19073-BLP-ARC-RVT-LRH_R19_FITOUT_helendK7GN4.rvt
KEY PLAN
A2
A3
A4
8400
A5
8400
A6
8400
A7
8400
ZONE A
8700
ZONE B
ZONE C
ZONE D
ZONE E
MMSP-020
AA
DIALYSIS AREA
KEY PLAN
FIHR-083
ELGP-109.2 1200
2400 600
ELBO-012 ELBO-012
1100 1100
MMSP-020
200
FQCW-008 MMGE-048 FQCW-035 MMGE-142 FQCW-015
HWA-01 JWF1-A
HVB-01
WCST-AMB 05-095 A52-0003
MMSP-035.1
MMGE-178 DIA-01
BC-04
ITSE-006 ITSE-006
HVB-01
JDU3-7A
JDU3-7A BENL-60C
JSA1-C
JSA1-C LIFX-016
JCA4-6B
3
HVB-01
BC-04
FIDI-001
P-dry arm 1B (P1)
MMSP-035.1
DIA-01
HYTP-039 HYDR-015 ELGP-208.2 900
1100
ITNE-007
FQBS-018
FQBS-018
EQ
HVB-01
EQ
425
3
2
EQ
WP-01
ITCL-026
EQ
AD
ELGP-208.2 900
C
P-wet arm 1A (P2)
LIFX-017 ITNE-052
ITIN-016
ELGP-109
MMGE-019
2500 ELBO-012
FIBM-019.1
1200
JBH1 JWF1-A
1100
MMGE-142FQCW-035 MMGE-048
FQCW-008
FQCW-015 FQSM-036 P-dry arm 1B (P1)
C3 FOR CONSTRUCTION C2 FOR CONSTRUCTION C1 FOR CONSTRUCTION REV AMENDMENTS
LIFX-017 FQTA-013
ITNE-008 MMGE-164 FQBS-019
MMBE-070
FIBM-006 above
FQBS-018
ELGP-110 ELBO-012 ELBO-012
600 1100 1100
ELBO-012
1100
ELPR-011
1100
MMBE-013
Billard Leece Partnership
T +61 3 9656 5000 E info@blp.com.au www.blp.com.au
CLIENT ELGP-208.2 900
ITBU-012 FIHR-004
ELGP-201
MMSP-020 BC-04
PBIC-BA 05-023 A51-05-023
ITNE-007
20/06/2022 07/06/2022 23/07/2021 DATE
Level 20/485 LaTrobe Street Melbourne 3000 Victoria, Australia
MMSP-035.1
WP-01
ITNE-007
BC-04
ELGP-208.2 900
2
HWA-01
ITSE-006
FQBS-018
FIHR-029
ELEC EL-G-05
HVB-01
425
ELGP-201
HVB-01
600
MMMI-330
3
300 200
UB
ELGP-208
1
ITSE-006
4
A51-05-091-1
1
A51-05-012-2
ELBO-020
ST-BS 05-099
B-MEQ 05-053 A51-01-079 (S)
SHW-01L
ENS ICU 05-091 A51-05-091
1100
4
600 600 600
ITNE-007
600 600 600
FIDI-014 FIHR-019 MSP-CC3-HX FIRT-016 HWC-02L
ELPR-011
MMGE-033
500
ELGP-208 ELGP-208 ITIN-026
WCF-01R
HWC-02R
ELEC EL-G-02
B-HW 05-044 A80-0002
FIHR-004 ITBU-012
HWB-01
MMGE-119
REDUCED PRESSURE ZONE DEVICE BOX REFER TO HYDRAULIC DOCUMENTS FOR DETAIL, AT 1500MM AFFL TYPICAL. BLUE ARROW INDICATES THE SIDE OF ACCESS PANEL IS FACING.
DIALYSIS AREA
ELGP-109.2 900
MMBE-013
1100 600 1100 1100
ELGP-208 ELGP-208 ITIN-026
600 600 600 1100
FIDI-001
HYDRAULIC VALVE BOX REFER TO HYDRAULIC DOCUMENTS FOR DETAIL, AT 300MM AFFL TYPICAL UNLESS NOTED OTHERWISE. BLUE ARROW INDICATES THE SIDE OF ACCESS PANEL IS FACING.
RPZD-01
MMSP-020
MMBE-068
FIBM-006 above
FQBS-019 MMGE-164 ITNE-008
ELBO-012 ELGP-110 ELBO-012 ELBO-012
ITNE-052
MMGE-119
600 600 600
ENS ICU 05-090 A51-05-091 (M)
MMMI-330
FIHR-029
4
ROOM LAYOUT SHEET REFERENCE, REFER TO RLS FOR ROOM ELEVATIONS
MMGE-178 LIFX-017
FQTA-013
ITCL-014
ELGP-208 ELGP-208 ITIN-026
ELBO-015 ITIN-016
600 600
600
1600 1400
ELGP-208
ITCL-037
WCF-01L
2
HVB-01
600
ITCL-037
MMGE-024
SHW-01L
WP-01
ITCL-026
JCU2-9C
ELGP-208
MMGE-119
MMBE-045
FQSM-036
INTERNAL ELEVATION MARKER, REFER TO ROOM LAYOUT SHEET FOR DETAILS, REFER TO A51-SERIES
HVB-01
xA51-05-052-1
HWA-01
UB
JDU3-7A
JSA1-C
1200
A51-05-102-2
MMGE-034
WP-01
ITNE-007
MMGE-142 FQCW-035 FQCW-008 MMGE-048 FQCW-015
PBIC-DIA 05-012 A51-05-012
1
xA51-05-057-1
1335
ELBO-015
A51-05-102-2
MMGE-087
600
B-MEQ 05-055 A51-01-079 (S)
FQBS-018
B-HW 05-043 A80-0002
FE-01
3
1200 1200 1200 1200
5
BENL-60C JSA1-C
FE-01
FQSN-069
FIHR-016 FQCW-044.1
ITIN-016
2
JDU3-7A
JDU3-7A
1100
JBH1 JWF1-A
1100
1100
B-MEQ 05-051 A51-01-079 (S)
HWA-01
MED 05-063 A51-05-102 900 900
1100
1200 1200 1200 1200
1200
ELGP-208 ELGP-109 ELGP-109 ITIN-026
ELBO-015
FIHR-016 FQCW-044.1
ITNE-049 ITSE-006
ITNE-007
4
FQSN-069
300
MMGE-119
2
xA51-05-098-1
FQBS-018
1
ITCL-004 ITCL-008
1100 1100 600
JCU2-9C
JCA4-6B LIFX-016
ELGP-208
UB
1100
ELBO-012 ELBO-012 ELGP-110
ITSE-006
1100
ELBO-012
ITNE-049
ELPR-011
ELGP-208.2 1100
600 600 600
600
FQSM-036
ELGP-208 ELGP-208 ITIN-026
ITNE-008 MMGE-164 FQBS-019
LIFX-017 WCF-02
RPZD-01
600 1200
2310
600 600 600
600 600 600 ELGP-109.2 1100
HWC-04R-A
ITNE-052
2
A51-05-022-2 FIBM-006 above FIRT-028
1100 1100
6
FQSN-069
300 200
600 600 600
4
ELGP-110 ITIN-016
300
C
FIHR-004 ITBU-0121
MMBE-013 MMBE-070 MMSP-020
ST-BS 05-098 -
ELBO-015
HVB-01
FQBS-018
600 600 600
HWA-01
200
PBIC-BA-DIA 05-022 ELBO-020 A51-05-022
ELGP-201 ELGP-208.2 900
2400
1
ELGP-208.2 900
STAIR 7 ST7-G
ELGP-208 ELGP-208 ITIN-026
ELGP-208 ELGP-208 ITIN-026
ELPR-002
ELGP-109
ITIN-026 ELGP-208 ELGP-208
MMGE-019
ITCL-014
ITIN-026 ELGP-208 ELGP-208
LIFX-017 ITNE-052
FQBS-018
HVB-01
ITNE-007
UB
ELGP-208.2 1100
210
ITNE-007
FIBM-019.1
1100
ITIN-016
FIDI-001
ITNE-052 HWB-01
FQSM-036
DIA-01
ITIN-016
MMGE-033
MMGE-142 FQCW-035 MMGE-048 FQCW-008 FQCW-015 FIDI-001
ELGP-208.2 900
HYTP-039 HYDR-015 RPZD-01
450
MED 05-102 A51-05-102
1340
MMGE-049 MMGE-178 DIALYSIS AREA
FQSN-069
ELGP-109 ITIN-016
ITNE-008 FQBS-019 MMGE-164
FQTA-013
BC-04
JSF3-18
FQSM-046 LIFX-016
CIRCULATION ICU-CIRC-06
MMGE-033
ELGP-208 ELGP-109 ELGP-109 ITIN-026
JSF3-18 FQSM-046 LIFX-016
2500 ELBO-012
600
3
FIBM-019.1
FIBM-006 above
MMBE-013 MMBE-068 LIFX-017
MMGE-019
MMGE-049
300
B-HW 05-042 A80-0002
ELGP-109
MMGE-033 ELGP-223
PBIC-E 05-011 A51-05-010 (S)
LIFX-017
PBIC-E 05-020 A51-05-010 (S)
HWA-01
ITIN-016
FIBM-019.1
600
FF&E CODE - SPECIAL JOINERY, REFER TO A61-0000 FOR JOINERY DRAWINGS
A51-0X-XXX
HWA-01
HVB-01
FQSM-046
1
1
LIFX-017 ITNE-052
300
FIRT-028
HVB-01
FQSM-046
1
ELGP-208.2 900
P-wet arm 1A (P2)
C
ITCL-014
B-RES 05-047 A51-01-080
ELGP-223
CIRCULATION ICU-CIRC-05
ELGP-109.2 900
TERRACE ICU-EXT-02
UB
FQSM-046
ELGP-208.2 900
ITBU-012 FIHR-004
ELGP-201
200
LIFX-016
MMGE-164
HVB-01
HWA-01
3
1
A51-05-013-2 ELBO-020
FIRT-031
MMGE-164 ITNE-008 FQBS-019
600
600
B-HW 05-041 A80-0002
1100
FF&E CODE, REFERS TO EQUIPMENT UNITS, REFER TO KIT OF PARTS DRAWINGS A71-SERIES & A80-SERIES
FISJ-###
750
ELGP-109 ELGP-110
860
1100 1100 1100 600
600 1100 1100 1100
ELPR-011
C
FIHR-004 ITBU-012
ELGP-109.2 600
ELGP-110 ELBO-012 ELBO-012 ELBO-012
2
ELGP-208.2 1100
ELGP-201
REFER TO ROOM 05-010 FOR FFE AND SET-OUT DETAILS U.N.O.
ELGP-208.2 1100
ELBO-012 ELBO-012 ELBO-012 ELGP-110
1
FF&E CODE, REFER TO A60 TYPICAL JOINERY DRAWING SERIES FOR DETAILS
ELGP-109.2 900
FQTA-013
MMBE-068 MMBE-013
FIBM-006 above
4
600
FQBS-019 ITNE-008 MMGE-164
FIDI-001
ITBU-012
C
ELGP-208 ELGP-208 ITIN-026 UB
1200
ITNE-052
ITCL-014 ELBO-020
ELGP-208
300 200
PBIC-DIA 05-017 ELBO-020 A51-05-012 (S) FIHR-004 ELGP-201
ELGP-208
HWA-01
1200
B-MEQ 05-056 A51-01-079 (S)
FQSM-046
FF&E CODE, REFER TO A14-0000 FF&E SCHEDULE FOR DESCRIPTION
JCAX-01
HWB-02R
LIFX-017
MMSP-020
300
MMBE-013
2400
FQSM-046
200
1200
ELGP-208.2 1100
ITIN-016
ELGP-208.2 900 ELGP-208.2 900
ELGP-109
190
ELBO-012
MMGE-019 LIFX-017 ITNE-052
FQSM-046
ELGP-208.2 900
CIRCULATION ICU-CIRC-04
300
1100
FIDI-001
ELGP-208.2 1100
ELBO-012
1100
ITCL-014
HVB-01
2 POLE ISOLATOR C3 ADDED FOR PATIENT LIFT
HVB-01
ITIN-016
600
FQSM-046
FIBM-019.1
600
CIRCULATION ICU-CIRC-03
FIBM-019.1
JWF1-A JBH1
MMGE-033
MMBE-013 MMGE-033
LIFX-016 FQSM-046
FQSM-046 FQSM-036
FIHR-000 FQCW-015
P-dry arm 1B (P1)
MMSP-035.1
ELGP-208.2 1100
ELGP-110
B-RES 05-048 600 A51-01-080 ELGP-223
ELGP-223
MMGE-142 FQCW-035 MMGE-048 FQCW-008 FQCW-015
2
HWA-01
600
FQSM-036
BC-04
3
MMGE-019
ITNE-052 LIFX-017
MMGE-048 FQCW-008
MMGE-142 FQCW-035
PBIC-E 05-013 A51-05-013
FIRT-028
ITNE-007
FIDI-001
ELGP-208.2 1100
ELBO-020
ELGP-110
ITNE-007
FIBM-019.1
FQSM-036
ELGP-110
ITNE-007
600
ELBO-012
JWF1-A
MOUNTING HEIGHT 'C' FOR CEILING MOUNTED 'F' FOR FLOORBOX 'UB' FOR UNDER BENCH MOUNTED NOTE: REFER TO SERVICES DRAWINGS FOR DETAILS
ELGP-208.2 1100
JWF1-A
LIFX-016
JWF1-A
ITNE-007
ELGP-208
600
REFER TO ROOM 05-013 FOR FFE AND SET-OUT DETAILS U.N.O.
LIFX-017
ITIN-016
HWA-01
HVB-01
FF&E CODE - SERVICES
HWA-01
HVB-01 600
B-MEQ 05-052
FQBS-018
300 270
ELGP-109.2 1100
MMGE-164 ITNE-008 FQBS-019
1
A51-05-010-2 FQCW-008 MMGE-048
ITNE-049 MMBE-068
LIFX-017
LIFX-016
300 200
NOTE: DASHED LINES TYPICAL INDICATE LOOSE FF&E OR FIXTURES ABOVE
FF&E TAGS
300 200
ITNE-007
ELGP-208
ELGP-208
600 600 600
PBIC-E 05-018 A51-05-010 (S)
1100 1100
PBIC-E 05-010 A51-05-010
ELGP-208.2 1100
UB ITSE-006
600 600 600
FQBS-018
4
600 600 600
ELGP-208 ELGP-208 ITIN-026
FIRT-028
FQBS-018
ST-BS 05-100 -
ITIN-026 ELGP-208 ELGP-208
PBIC-E 05-016 A51-05-013 (S)
1100 1100 600 1100
600 600 600
ELBO-012 ELBO-012 ELGP-110 ELBO-012
ELBO-020
MMSP-020
ELGP-208 ELGP-208 ITIN-026
FQBS-018
C
600 2400
ELBO-012 ELBO-012
FIRT-031
MMBE-013
MMSP-020
NOTE: - (M) REFERS TO MIRRORED SET-UP TO ROOM LAYOUT SHEET - (S) REFERS TO SIMILAR SET-UP TO ROOM LAYOUT SHEET
MMSP-020
MMGE-033
ITNE-007
UB
ELGP-201
ELGP-110 ELGP-109
MMGE-164 ITNE-008 FQBS-019
ELGP-208.2 1100
ITNE-049
ITIN-026 ELGP-208 ELGP-208
ITNE-007
407
FIHR-004 ITBU-012
ELGP-208.2 900
2400
ITSE-006
1200 ITIN-016
300
ELGP-208.2 900
ELBO-020
C
FIHR-004 ITBU-012
ELGP-109.2 600
ITCL-026 ELGP-109
ITCL-014
HWA-01
FQBS-018
ITNE-007
ITCL-014
1100
ROOM NAME ROOM NUMBER ROOM LAYOUT SHEET REFERENCE
ROOM NAME 01-001 A51-01-001
PBIC-E 05-014 A51-05-013
HVB-01
300 200
ELGP-201
REFER TO ROOM 05-011 FOR FFE AND SET-OUT DETAILS U.N.O.
FQSM-046
MMGE-131
HVB-01 MMGE-019
ST-BS 05-101
HWA-01 ELPR-011
ELGP-208
1100 1100 600 1100
FIBM-019.1 LIFX-017 ITNE-052
JWF1-A JBH1
MMGE-019
FIBM-006 above
ELBO-012 ELBO-012 ELGP-110 ELBO-012
FIDI-001
13.
REFER TO ROOM 05-013 FOR FFE AND SET-OUT DETAILS U.N.O.
FQBS-018
RPZD-01
1200
JBH1 JWF1-A
ELBO-020
MMGE-033
600 600 600
B-LIN 05-045 A51-02-072 (S)
WCF-01R SHW-01L
FQBS-018
0 55
FQSM-036
AC
ELGP-208 ELGP-208 ITIN-026
FQBS-018
600 600 600
MSP-CC3-HX
600 600 600
MMIC-095
ELGP-208.2 900
FQSM-046
FIRT-028
12.
ITNE-007
ELGP-208 ELGP-208 ITIN-026
MMIC-097 HYTP-008 HYTP-013
1600
BC-04
FIHR-026
ELPR-011
ENS ICU 05-092 A51-05-091(S)
1100
MMSP-035.1
ITNE-007
HWC-02L MMGE-048 MMGE-048
1500 1500
SNK-02AL ELGP-208
B-B/FW 05-057
JSR1-A
FIHR-053
HVB-01
ITCL-014
MMGE-164 FQBS-019 ITNE-008
MMSP-035.1
ELBO-012
FISJ-202
300 350
HWA-01
EQ
FQCW-006
HYDR-004
FQCW-044.3 FIHR-016
500
FIHR-053
DU 05-069 A51-01-084
HWB-02R
B-LIN 05-046 A51-02-072 (S)
FISJ-201
CIRCULATION ICU-CIRC-03
C
ELGP-208.2 900 1100
1100
HVB-01
600 ø
FIBM-019.1
PBIC-E 05-019 A51-05-013 (S)
MMGE-142
JWF1-A
HVB-01
0 30
MMGE-048
FQCW-035
11.
HWA-01
ELGP-208 ELGP-208 ITIN-026
ELGP-201
B-B/FW 05-058
ELPR-003 ELGP-106
2400
1100 ELBO-012
ELGP-109
MMBE-068 FQCW-008
ITCL-014
FIHR-004 ITBU-012
10. 350 300
ITCL-026
ELGP-106
1100 ELBO-012
FE-01
ELGP-208.2 1100
MMSP-020 FQCW-015
9.
500
HVB-01
1100 1100 1100 600
FIRT-028
FIDI-001
ELGP-109.2 900
LIFX-017
ELBO-012 ELBO-012 ELBO-012 ELGP-110
REFER TO ROOM 05-013 FOR FFE AND SET-OUT DETAILS U.N.O.
MMGE-019
RPZD-01
ELBO-020
1200
ELGP-208.2 900 ELGP-208.2 900
BC-04
EQ
8.
PBIC-E 05-015 A51-05-013 (S)
600
ELGP-109.2 1200
ITIN-016
ELGP-110
7.
MMSP-020
MMGE-137
HVB-01
HWA-01
0 20
JBH1 JWF1-A LIFX-017 ITNE-052
300
6.
600 1100 1100
REFER TO ROOM 05-013 FOR FFE AND SET-OUT DETAILS U.N.O.
200
FIHR-026 FIHR-026 MMGE-048 FIHR-026 FIHR-026
CONTRACTORS AND THEIR ASSOCIATES SHALL VERIFY ALL DIMENSIONS OF THIS DRAWING AND SITE CONDITIONS PRIOR TO ANY WORK COMMENCING. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE. ALL DIMENSIONS ARE TO THE FINISH FACE OF WALL UNLESS NOTED OTHERWISE. ALL DIMENSIONS SHALL BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK. RELEVANT PARTY SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES. THE MANUFACTURER SHALL NOT COMMENCE ANY WORKS PRIOR TO RETURN OF APPROVED SHOP DRAWINGS SIGNED BY THE RELEVANT CONSULTANTS. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS, SPECIFICATIONS, REPORTS AND DRAWINGS. ALL A14 SERIES DRAWINGS ARE TO BE READ IN CONJUNCTION WITH JOINERY DRAWINGS (A60- & A61-SERIES) & KIT OF PARTS DRAWINGS (A71- & A80-SERIES) E.G. SET-OUT DIMENSIONS. REFER TO A15-SERIES FOR FLOOR FINISHES, WALL FINISHES, SKIRTING TYPE AND FEATURE FINISHES. REFER TO WALL SETOUT DRAWINGS (A12SERIES) FOR WALL TYPES AND DOOR NUMBERS. REFER TO INTERNAL GLAZED SCHEDULES FOR INTERNAL WINDOW TYPE/SIZES, REFER TO A82-SERIES. FFE ITEMS SHOWN IN THIS DRAWING ARE INDICATIVE ONLY, SHOWN FOR PLANNING PURPOSES AND SERVICES COORDINATION, REFER ALSO TO DOCUMENTS OF FF&E CONSULTANT AND RELEVANT SCHEDULES IN A96-SERIES. AV EQUIPMENT & ASSOCIATED SERVICES ARE INDICATIVE ONLY, SUBJECT TO ICT BRIEF AND AV CONSULTANT DOCUMENTS. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL SERVICES DRAWINGS AND DOCUMENTS.
5.
1100
ELGP-110 ELBO-012 ELBO-012
300
CIRCULATION ICU-CIRC-09
2400
0 30
PBIC-E 05-021 A51-05-013 (S)
2500 1100 1100
2. 3.
MMSP-035.1 ELBO-012
ELBO-020
HVB-01 HWB-01
HVB-01 ELBO-020
ITCL-014 ELGP-109
FIRT-016
ANTE 05-026 A51-01-016
HWA-01
ELPR-010 MSP-CC5-HX
FIRT-034 FQGE-011
A51-05-029-1
FIDI-025
AIRLOCK ICU-AIR
600
4.
1275
ITCL-014 ELGP-109 ELBO-012 ELBO-012
ELPR-011
MMSP-020
ITCL-037
MMGE-025
RPZD-01
ITNE-052 LIFX-017
A51-05-024-2
ELBO-020
600
2
250
FIDI-001
JWF1-A JBH1
HVB-01
3
FIDI-001
MMGE-033
1
1400
ISO-N-DIA 05-024 A51-05-024
600
MMSP-035.1
C
FIHR-004 ITBU-012
2
3
ELGP-110
HVB-01
ELPR-002
FIHR-026 FIHR-026 FIHR-026 FIHR-026
MMGE-137 MMBE-068
ITIN-016
1
ITCL-037
WCF-05
800 HWB-07R MMGE-019
ELGP-201
4 ITNE-008 MMGE-164 FQBS-019
1100
C
ELGP-110
FIDI-001
ELBO-012
ANTE 05-027 A51-01-016
MMGE-033
1100
ELGP-208.2 1100
BC-04
ELGP-201 600
FQSM-036
HWB-01
MMBE-059
MMBE-013
FIBM-019.1
ITCL-014
MMSP-035.1 FIDI-022
MMGE-048
FQTA-013 MMSP-020
ELGP-208.2 1100
GENERAL NOTES: 1.
TERRACE ICU-EXT-01
4
C
FQSM-036
600
SHW-04L
ENS-SP 05-029 A51-05-029
FIDI-030
ITBU-012 FIHR-004
ITNE-008 MMGE-164 FQBS-019
ELGP-101
MMGE-019
ISO-N 05-025 A51-05-025
MMBE-013
200 FIBM-019.1 300
ELBO-012 1100 ELBO-012 1100
2
2400
10 00
12 80
3
A51-05-025-2
HVB-01
600
250 300
AB
ITCL-037
1200
1
4
JCA3-6F ITNE-052
ITIN-016
1200
MMBE-068
A51-06-014-1
FIDI-025
1600 1400
FIHR-026
ITIN-016
1600 1400
JSR1-A
HWB-07L
MMGE-024 SHW-02R
ELGP-109
A51-05-030-1
ENS-SP 05-030 A51-05-030
HWA-01
ITCL-004 ITCL-008
3
4 600
ITCL-004 ITCL-008
MEEX-008.2
JCA3-6F
MMSP-020
1
ITCL-037
WCF-04L
MMGE-048 FQCW-035 MMGE-142
LIFX-017 ITNE-052
BC-04
MMGE-049
FQCW-015 FQCW-008
A51-05-030-1
MMGE-178
ELGP-208.2 900
DIA-01
ELGP-109.2 900
1100
HYTP-039 HYDR-015
ELGP-223
ELGP-208.2 900
ELGP-208.2 900
MMGE-142 MMGE-048 FQCW-015
2 FIRT-016
JBH1 JWF1-A
MEEX-008.2
ELBO-012
LIFX-017
RPZD-01
ELGP-109.2 900
FQCW-008
LIFX-017
1400
FQCW-035
4 C
1 3
P-wet arm 1A (P2)
2
VHBA
ELGP-208.2 900
A51-05-023-2 PROJECT NAME
LATROBE REGIONAL HOSPITAL STAGE 3A
CONTINUED ON SHEET:A14-0012 ENSUITE SHIFTED TO ALLOW SETDOWN TO C3 AVOID CLASHING WITH THE CONTROL JOINT
HVB-01
SHEET NAME
PLAN - FF&E - GROUND LEVEL - ZONE A1
PROJECT ARCHITECT:
DRAWN BY
Author CHECKED BY
IZ PROJECT NO.
REVISION DATE
19073 DRAWING NO
20/06/2022
SCALE
1 : 50 @ A0 REVISION NUMBER
[C3]
FOR CONSTRUCTION
_LAST ACCESSED: 6/21/2022 7:52:22 PM
A14-0011
_DOCUMENT NUMBER: 19073-A14-0011- [C3]
N
REGISTRATION NO.
Excerpt from architectural drawing set / Revit 9
A60-0010
14
A60-0010
30
A60-0010 30MM DOOR OVERHANG/GRIP HANDLELESS WALL UNITS
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
30MM DOOR OVERHANG/GRIP HANDLELESS WALL UNITS 1800 - MAX SHELF HEIGHT
30MM DOOR OVERHANG/GRIP HANDLELESS WALL UNITS
SPLASHBACK UP TO CABINET BASE
REFER A80 FOR SANITARY FITTING SET-OUT
1800 - MAX SHELF HEIGHT
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
ADJ
6
30
30
A60-0010
CUTOUTS TO DOOR PANEL TO SUIT GLOVE DISPENSER REF FFE SCHEDULE
EQ
13MM COMPACT LAMINATED PANEL
ADJ
30
6
1800 - MAX SHELF HEIGHT
EQ
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
A60-0010
18MM LAMINATED PANEL
HEIGHT
18MM LAMINATED PANEL
30
A60-0010
EQ
11
A60-0010
ADJ
13
A60-0010 EQ
TYPICALLY COMBINED WITH JSA4 OPEN SHELF
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
18MM LAMINATED PANEL
10
A60-0010
2
2
A60-0010
1300
EQ
1600 - HEIGHT AFFL
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
1800 - MAX SHELF HEIGHT
1800 - MAX SHELF HEIGHT
720.0 .
1800 - MAX SHELF HEIGHT
EQ
TYPICALLY COMBINED WITH JSA4 OPEN SHELF
900.0 .
18MM LAMINATED MDF PANEL. WITH 4MM CLEAR POLYCARBONATE GLAZING
ADJ
ADJ
7
HEIGHT AFFL
1400.0.
18MM LAMINATED PANEL. WITH 4MM CLEAR POLYCARBONATE GLAZING
ADJ
ADJ
DOOR WITHOUT OVERHANG. TO INCLUDE PUSH TO OPEN MAGNET
1800 - MAX SHELF HEIGHT
8
A60-0010
DOOR WITHOUT OVERHANG. TO INCLUDE PUSH TO OPEN MAGNET
JCA3 & JCA8 *WATERPROOF COMPACT LAMINATE DETAILS
1
A60-0010 JBH1
2
A60-0010
HEIGHT
ADJ
ADJ
HEIGHT
8
A60-0010
JCA3 JOINERY - CUPBOARD - ABOVE BENCH
1
A60-0010 JBH1
4
2
A60-0010
18MM LAMINATED PANEL
HEIGHT
18MM LAMINATED PANEL
ADJ
ADJ
1500.0.
1
A60-0010 JBH1
HEIGHT
2
A60-0010
JCA8 JOINERY - CUPBOARD - ABOVE BENCH
1
A60-0010 JBH1
HEIGHT AFFL
2
A60-0010
2100.0.
JCA6 JOINERY - CUPBOARD - ABOVE BASIN
JCA5 JOINERY - CUPBOARD - ABOVE BENCH
1
A60-0010 JBH1
HEIGHT AFFL
1
A60-0010 JBH1
HEIGHT
JCA4 JOINERY - CUPBOARD - ABOVE BENCH
JCA2 JOINERY - CUPBOARD - ABOVE BENCH
1
A60-0010 JBH1
C:\Users\fionam\Documents\19073-BLP-ARC-RVT-LRH_R19_FITOUT_fionamEK3GH.rvt
JCA1 JOINERY - CUPBOARD - ABOVE BENCH 2700.0FCL
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
150.0 . 0.0
FFL
JCA1 - ELEVATION
JCA1 - SECTION
JCA2 - ELEVATION
JCA2 - SECTION
JCA4 - ELEVATION
WIDTH
JCA4 - SECTION
JCA5 - ELEVATION
WIDTH
JCA5 - SECTION
JCA6 - ELEVATION
JCA6 - SECTION
JCA8 - ELEVATION
JCA8 - SECTION
JCA3 - ELEVATION
WIDTH
GENERAL NOTES:
JCA3 - SECTION
• This drawing is copyright of Billard Leece Partnership pty ltd • Do not scale this drawing • All dimensions to be confirmed on site - any inconsistencies to be reported to architect immediately. • The Builder/Contractor shall verify job dimensions prior to any work commencing. Figured dimensions shall take precedence over scaled work • All architectural drawings to be read in conjunction with drawings provided by others including but not limited to structural, civil & services drawings, specifications and reports.
WIDTH
JCA1 - PLAN
JCA2 - PLAN
PREVIOUS CODE FIJO-156
ITEM CODE JCA1-5A
DESCRIPTION
JCA4 - PLAN
PREVIOUS CODE FIJO-143 ITEM CODE
HEIGHT DEPTH WIDTH HEIGHT AFFL 500 300 300 1600
CUPBOARD: wall mount, single door, adjustable shelves
JCA2-V
350
JCA5 - PLAN
PREVIOUS CODE FIJO-147; FIJO-148 FOR LOCKABLE CUPBOARD
DESCRIPTION
HEIGHT DEPTH WIDTH HEIGHT AFFL 500 300 TO A61 SERIES REFER
CUPBOARD: wall mount, double door, adj shelves
ITEM CODE
DESCRIPTION
JCA4-6B CUPBOARD: wall mount, double door, glazed, adj shelves JCA4-6B(L) CUPBOARD: wall mount, double door, glazed, adj shelves, lockable
REFER TO A14 DRAWINGS AND A61 DRAWINGS FOR INSTANCES OF LEFT OR RIGHT HANDED INSTALL
JCA6 - PLAN
JCA8 - PLAN
PREVIOUS CODE FIJO-222
HEIGHT DEPTH WIDTH HEIGHT AFFL 600 350 900 1500 600 350 900 1500
ITEM CODE JCA5-6A
DEPTH
200
DEPTH
DEPTH
DEPTH
DEPTH
1000
REFER A80 FOR SANITARY FITTING SET-OUT
REFER TO A14 DRAWINGS AND A61 DRAWINGS FOR INSTANCES OF LEFT OR RIGHT HANDED INSTALL
JCA3 - PLAN
PREVIOUS CODE FIJO-140
DESCRIPTION CUPBOARD: wall mount, sliding door, glazed, adj shelves
HEIGHT 600
DEPTH 350
WIDTH 900
ITEM CODE JCA6-8
HEIGHT AFFL 1500
DESCRIPTION CUPBOARD: wall mount, double door, glove dispenser slot cutout, no bottom carcass
HEIGHT 800
WIDTH 1000
ITEM DESCRIPTION CODE JCA8-6C CUPBOARD: wall mount, single door, adjustable shelves JCA8-6D CUPBOARD: wall mount, single door, adjustable shelves JCA8-6E(L) CUPBOARD: wall mount, single door, adjustable shelves, lockable JCA8-7B CUPBOARD: wall mount, single door, adjustable shelves JCA8-7C CUPBOARD: wall mount, single door, adjustable shelves JCA8-7E CUPBOARD: wall mount, single door, adjustable shelves JCA8-7H CUPBOARD: wall mount, single door, adjustable shelves
HEIGHT AFFL 1300
DEPTH 200
HEIGHT DEPTH WIDTH HEIGHT AFFL 600 350 400 1500 600 350 500 1500 600 600 450 1500 700 700 700 700
300 300 350 300
350 450 450 400
1400 1400 1400 1400
PREVIOUS CODE FIJO-143
PREVIOUS CODE FIJO-143
ITEM CODE JCA3-4A JCA3-6B JCA3-6B(L) JCA3-6C JCA3-6D JCA3-6D(W) JCA3-6F JCA3-6F(L)
ITEM CODE JCA3-6G(W) JCA3-6J JCA3-7G(L) JCA3-7H JCA3-7J JCA3-7K JCA3-8A JCA3-8B JCA3-V
JCA3-6G
DESCRIPTION HEIGHT DEPTH WIDTH CUPBOARD: wall mount, double door, adj shelves 400 600 700 CUPBOARD: wall mount, double door, adj shelves 600 350 600 CUPBOARD: wall mount, double door, adj shelves, lockable 600 350 600 CUPBOARD: wall mount, double door, adj shelves, lockable 600 350 650 CUPBOARD: wall mount, double door, adj shelves 600 350 700 CUPBOARD: wall mount, double door, adj shelves, waterproof 600 350 700 CUPBOARD: wall mount, double door, adj shelves 600 350 900 CUPBOARD: wall mount, double door, adj shelves, lockable Refer A60 600 350 900 drawing series for dimension details CUPBOARD: wall mount, double door, adj shelves, waterproof 600 350 850
DESCRIPTION CUPBOARD: wall mount, double door, adj shelves, waterproof CUPBOARD: wall mount, double door, adj shelves CUPBOARD: wall mount, double door, adj shelves, lockable CUPBOARD: wall mount, double door, adj shelves, lockable CUPBOARD: wall mount, double door, adj shelves, lockable CUPBOARD: wall mount, double door, adj shelves, lockable CUPBOARD: wall mount, double door, adj shelves CUPBOARD: wall mount, double door, adj shelves CUPBOARD: wall mount, double door, adj shelves
HEIGHT DEPTH WIDTH 600 350 850 600 350 620 700 350 600 700 350 800 700 350 700 700 350 650 800 600 700 REFER A61 SERIES 800 TO 200 600
A61 SERIES NOTES DRAWINGS TO BE READ IN CONJUNCTION WITH A96-03 FFE SCHEDULE, A96-04 MATERIALS AND PRODUCTS SCHEDULE, A96-06 SANITARY SCHEDULE, A82 INTERNAL WINDOW SCHEDULE AND ALL RELEVANT SPECIFICATIONS. REFER TO A50 DRAWING SERIES FOR ALL INTERNAL ELEVATIONS NOT SHOWN.
* Waterproof indicated in description refer to section and details for compact laminate construction
REFER TO A60 DRAWING SERIES FOR ALL TYPICAL JOINERY SECTIONS AND DETAILS. FURNITURE SHOWN ON PLANS ARE INDICATIVE. REFER TO FURNITURE SCHEDULE FOR DETAILS. CONTRACTOR TO PROVIDE SHOP DRAWINGS
15
A60-0010 A60-0010
MIRROR TO INSIDE DOOR FROM 1000AFFL
SIT TO STAND DESK FURNITURE SHOWN INDICATIVELY
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
FF&E CODE, REFER TO A14-0000 FF&E SCHEDULE FOR DESCRIPTION
JCAX-01
FF&E CODE, REFER TO A60 TYPICAL JOINERY DRAWING SERIES FOR DETAILS FINISHES CODE, REFER TO A96-04 MATERIAL SCHEDULE FOR SPECIFICATIONS
PL-01
FF&E CODE - SERVICES
ADJ ADJ.
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
ELGP-208.2
MOUNTING HEIGHT NOTE: REFER TO SERVICES DRAWINGS FOR DETAILS
1200
DETAIL CALLOUT MARKER, REFER TO A60 SERIES FOR DETAILS
1
COUNTER BELOW SHOWN INDICATIVELY
600 - TYP
A60-0100
JOINERY BULKHEAD. REFER TO A60-0010 FOR DETAILS
JBH1
1000
SIT TO STAND DESK FURNITURE SHOWN INDICATIVELY
FIHR-000
18 MM LAMINATED ADJUSTABLE SHELF
ADJ.
RECESSED LED STRIP LIGHT WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
FINISHES & FF&E TAGS
ADJ
MIRROR TO INSIDE DOOR FROM 1000AFFL
700
VARIES
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
1700
1800 - MAX SHELF HEIGHT
EQ
HEIGHT AFFL
1800 - MAX SHELF HEIGHT
HEIGHT AFFL
WALL LININGS TO UNDERSIDE OF JOINERY UNIT. REFER TO A15 OR A61 FOR TYPE
9
ADJ.
150.0 . FFL
JSA5 - ELEVATION
HEIGHT AFFL 1350 1500 1350 1500
3
HEIGHT AFFL 1700
JSF6 JOINERY SHELVING FULL HEIGHT
1
TYPICAL TO PATIENT ENSUITE LEFT HINGE
3
ADJ
ADJ
ADJ
ADJ
ADJ
ADJ
ADJ
ADJ
DESCRIPTION CUPBOARD: tall, shelf unit, adj shelves, heavy duty CUPBOARD: tall, shelf unit, adj shelves, heavy duty
HEIGHT DEPTH WIDTH 2100 2100
600 600
450 600
21
1100
21
ADJ
A60-0010 A60-0010
A60-0010 A60-0010
28
ADJ
ADJ
ADJ
ADJ
ADJ
FIX
FIX
ADJ
ADJ
ADJ
1000
ADJ
ADJ
1000
ADJ
ADJ
21
A60-0010 A60-0010
ITEM CODE JSB1 JSB2
350 430
JSR1-C JOINERY - SHELVES - RECESSED
ADJ
HEIGHT
ADJ
500
ADJ
ADJ
A60-0010 A60-0010
HEIGHT AFFL
ADJ
ADJ
1800 - MAX SHELF HEIGHT
ADJ
30MM S-S ANGLE
HEIGHT
ADJ
ADJ
21
150.0 .
TYPICAL TO ACCESSIBLE PATIENT ENSUITE LEFT HINGE
TYPICAL TO ACCESSIBLE PATIENT ENSUITE RIGHT HINGE
28
A60-0010
29
C1 FOR CONSTRUCTION REV AMENDMENTS
A60-0010
ADJ
ADJ
ADJ
ADJ
FIX
FIX
JSF1 - ELEVATION
JSF1 - SECTION
JSF2 - SECTION
JSF2 - ELEVATION
WIDTH
JSF3 - SECTION
JSF3 - ELEVATION
WIDTH
JSF6 - ELEVATION
WIDTH
ADJ
29
A60-0010
JSR2 - SECTION
JSR1-A - ELEVATION
JSR1-C - ELEVATION
DEPTH 350
WIDTH 900
ITEM CODE DESCRIPTION JSF2-12 SHELVES: full height, adj shelves JSF2-12 SHELVES: full height, adj shelves
JSF3 - PLAN
SHEET NAME
110
DEPTH
560
DEPTH
WALL FACE CUTOUT HANDLE/GRIP
JSR1 - PLAN
REFER TO A14 DRAWINGS FOR INSTANCES OF LEFT OR RIGHT HANDED INSTALL
PROJECT ARCHITECT:
DEPTH 600 600
WIDTH 1200 1200
ITEM CODE DESCRIPTION JSF3-18 SHELVES: full height, adj shelves
DEPTH 600
WIDTH 1800
ITEM CODE DESCRIPTION JSF6-A Shelves: open, full height, 6 rows
CHECKED BY
Checker
PREVIOUS CODE FIJO-126
HEIGHT 2100
DRAWN BY
Author REGISTRATION NO.
JSF6 - PLAN
PREVIOUS CODE FIJO-126
HEIGHT 2100 2100
JSR1-C - SECTION
TYPICAL JOINERY - WALL MOUNTED
WIDTH
30MM S-S ANGLE
DEPTH
DEPTH
DEPTH
JSR1-A - SECTION
400
WALL FACE
JSF2 - PLAN PREVIOUS CODE FIJO-126
HEIGHT 2100
T +61 3 9656 5000 E info@blp.com.au www.blp.com.au
CLIENT
PROJECT NAME
JSR2 - ELEVATION
JSR2 - PLAN JSF1 - PLAN PREVIOUS CODE FIJO-126
Billard Leece Partnership VHBA
LATROBE REGIONAL HOSPITAL STAGE 3A
JSF6 - SECTION
WIDTH
WIDTH
ITEM CODE DESCRIPTION JSF1-H CUPBOARD: tall, shelf unit, adj shelves, heavy duty
23/07/2021 DATE
Level 20/485 LaTrobe Street Melbourne 3000 Victoria, Australia
ADJ
FFL
DEPTH
0.0
ADJ
WIDTH
350 350
TYPICAL TO PATIENT ENSUITE RIGHT HINGE
30
ADJ
ADJ
ADJ
2100 2100
A60-0010
ADJ
ADJ
1800 - MAX SHELF HEIGHT
ADJ
ADJ
ADJ
HEIGHT
ADJ
720.0 .
HEIGHT
1800 - MAX SHELF HEIGHT
HEIGHT
900.0 .
ADJ
HEIGHT DEPTH
A60-0010 A60-0010
A60-0010 A60-0010
ADJ
ADJ
ADJ
1800 - MAX SHELF HEIGHT
ADJ
DESCRIPTION CUPBOARD: tall, single door, fixed shelves, PPE storage CUPBOARD: tall, single door, fixed shelves, PPE storage
JSR1-A JOINERY - SHELVES - RECESSED
JSR2 JOINERY - TRAY - SHELVES RECESSED
30
ADJ
ITEM CODE JCR1-A JCR1-B
HEIGHT AFFL 1600
1
1500.0. 1400.0.
DEPTH 300
A60-0010 A60-0010
3
3
ADJ
HEIGHT 200
JBH1
A60-0010 A60-0010
ADJ
JSB1 - PLAN
PREVIOUS CODE FIJO-224
ITEM CODE DESCRIPTION JSA4-2A SHELF: wall mount
A60-0010 A60-0010
ADJ
ADJ
ADJ
WIDTH 1800
REFER TO A61 SERIES FOR HEIGHT
JBH1
A60-0010 A60-0010
DEPTH 350
REFER TO A61 SERIES FOR WIDTH
1
ADJ
HEIGHT 400
REFER TO A14 DRAWINGS FOR INSTANCES OF LEFT OR RIGHT HANDED INSTALL
JCR1 - PLAN
PREVIOUS CODE FIJO-152
ITEM CODE DESCRIPTION JSA3-A Shelves: open (above bench)
A60-0010 A60-0010 JBH1
ADJ
WIDTH 1800 1800 1600 1500
JSB1 - SECTION
400
1
A60-0010 A60-0010 JBH1
2100.0.
DEPTH 350 350 350 350
JSF3 JOINERY SHELVING FULL HEIGHT
JSF2 JOINERY SHELVING FULL HEIGHT
2700.0FCL
JSA4 - PLAN
PREVIOUS CODE FIJO-154.1
HEIGHT 750 600 750 600
JSB1 - ELEVATION
VOID BEHIND
JSA3 - PLAN
ITEM CODE DESCRIPTION JSA5-B Shelves: adjustable (above bench) JSA5-C Shelves: adjustable (above bench) JSA5-D Shelves: adjustable (above bench) JSA5-E Shelves: adjustable (above bench)
JCR1 - SECTION
300
WIDTH 1200 900 1200
JCR1 - ELEVATION
HEIGHT
DEPTH 350 350 350
JSA4 - SECTION
180
JSF1 JOINERY SHELVING FULL HEIGHT
HEIGHT 600 600
WIDTH VARIES
DEPTH
JSA5 - PLAN PREVIOUS CODE FIJO-152.2
ITEM CODE DESCRIPTION JSA2-A Shelves: adjustable (above bench) JSA2-C Shelves: adjustable (above bench) JSA2-E Shelves: adjustable (above bench)
WIDTH 600 450 900 600 500 470
JSA4 - ELEVATION
220
DEPTH 350 350 350 350 350 350
JSA3 - SECTION 1800 WIDTH
700
JSA2 - PLAN PREVIOUS CODE FIJO-152.1
HEIGHT 600 600 600 750 750 750
JSA3 - ELEVATION
DEPTH
DEPTH
DEPTH
JSA1 - PLAN PREVIOUS CODE FIJO-152
ITEM CODE DESCRIPTION JSA1-C Shelves: adjustable (above bench) JSA1-D Shelves: adjustable (above bench) JSA1-E Shelves: adjustable (above bench) JSA1-F Shelves: adjustable (above bench) JSA1-G Shelves: adjustable (above bench) JSA1-H Shelves: adjustable (above bench)
JSA1, JSA2, JSA5 - SECTION WIDTH
1100
JSA2 - SECTION
WIDTH
1800 - MAX SHELF HEIGHT
JSA2 - ELEVATION
HEIGHT
JSA1 - SECTION
HEIGHT AFFL
JSA1 - ELEVATION WIDTH
DEPTH
0.0
PREVIOUS CODE FISJ-069
HEIGHT 2100
DEPTH 400
WIDTH 450
ITEM CODE JSR2
DESCRIPTION Joinery: meal tray inserts unit
HEIGHT DEPTH 1000
560
WIDTH 400
ITEM CODE JSR1-A JSR1-C
DESCRIPTION JOINERY: recessed shelving, 1xGPO JOINERY: recessed shelving, DDA height, 2xGPO
HEIGHT 1100 1100
WIDTH 300 300
PROJECT NO.
REVISION DATE
19073 DRAWING NO
23/07/2021
A60-0001
SCALE
1 : 20 @ A0 REVISION NUMBER
[C1]
FOR CONSTRUCTION
_LAST ACCESSED: 28/07/2021 12:14:51 PM
10
15
ALL CUPBOARD AND DRAWER FRONTS, AND OPEN SHELVING TO BE PL-02 UNLESS NOTED OTHERWISE.
_DOCUMENT NUMBER: 19073-A60-0001- [C1]
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
720.0 .
15
A60-0010
300
TYPICALLY COMBINED WITH JCA1 AND JCA2 CABINETS
A60-0010
A60-0010 EQ
900.0 .
ADJ
15
A60-0010
1400.0.
ADJ
3
A60-0010 250
HEIGHT AFFL
1500.0.
ADJ
ADJ
GPO AND DATA POINTS LOCATIONS INDICATED ON ELEVATIONS AND PLANS. REFER TO ELECTRICAL AND SERVICES DRAWINGS FOR DETAILS AND SPECIFICATIONS
ALL INTERNAL CARCASSES TO BE WHITE MELAMINE
3
1800 - MAX SHELF HEIGHT
ADJ
ADJ
JBH1
A60-0010 400
ADJ
E4
A60-0010
3
A60-0010
HEIGHT
HEIGHT
HEIGHT
ADJ
ADJ
E4
A60-0010
3
A60-0010
JBH1
200
A60-0010
3
A60-0010
2100.0.
JBH1
1800 - MAX SHELF HEIGHT
A60-0010
JBH1
1
A60-0010
A60-0010
1800 - MAX SHELF HEIGHT
E4
JBH1
JSB1 JOINERY - SHELF - BENCH-TOP
1
1
A60-0010
HEIGHT
E4
JBH1
JCR1 JOINERY - CUPBOARD - RECESSED - PPE
900
1
A60-0010
A60-0010
JSA4 JOINERY - SHELVING - ABOVE BENCH
HEIGHT
1
JSA3 JOINERY - SHELVING - ABOVE BENCH
HEIGHT AFFL
2700.0FCL
JSA5 JOINERY - SHELVING - ABOVE BENCH
1400
JSA2 JOINERY - SHELVING - ABOVE BENCH
JSA1 JOINERY - SHELVING - ABOVE BENCH
Excerpt from architectural drawing set / Revit
FIDI-014
FQCW-018
HYTP-037 HYBA-009
FQCW-018
HYBA-078
FQCW-018
FIDI-031 FIDI-030
FIDI-025
FIDI-014
FIDI-031 FIDI-030
INDICATIVE SIDE WALL
INDICATIVE SIDE WALL
FIDI-025
F I D I -0 1 4
FIDI-031 FIDI-030
F I D I -0 2 5
500 NOM.
WORKS PRIOR TO RETURN OF APPROVED SHOP 6. UNLESS SHOWN OTHERWISE ON A14 DRAWING SERIES & A52 DRAWINGS SIGNED BY THE RELEVANT DRAWING SERIES, ALL WC'S SHALL BE 450mm MIN. FROM FINISHED CONSULTANTS. WALL FACE TO CENTRE OF TOILET PAN
1000 NOM.
FIDI-025
FIDI-031 FIDI-030
HWB-05 Handwash Facility Type B Concealed dispensers in overhead joinery
FIDI-025
FIDI-030
FIDI-031
FIDI-014
FIDI-025
FIDI-031 HYTP-037 FIDI-030
FIDI-014
FIDI-025
6. THIS DRAWING MUST BE READ IN CONJUNCTION 7. RED BOX ADJACENT TO GLOVEBOX DISPENSER INDICATING WITH ALL RELEVANT CONTRACTS, SPECIFICATIONS, CLEARANCE ZONE FROM OBSTRUCTION FOR RE-STOCKING ACCESSREPORTS AND DRAWINGS.
REAR VINYL
FIDI-014
FIDI-031 FIDI-030
FIDI-014
FIDI-014
FIDI-031 FIDI-030
FIDI-025
HYBA-086
9. PROVIDE NOGGING AS REQUIRED, ZONE SHOWN SHADED WITH PINK DASHED LINE BORDER (MINIMUM 18MM THICK STRUCTURAL PLYWOOD). FINAL COORDINATION ON SITE BETWEEN SUBCONTRACTOR & EQUIPMENT SUPPLIER. 10. INSTALLATION OF SANITARY FIXTURES AND EQUIPMENT IN LINE WITH MANUFACTURER'S SPECIFICATIONS AND INSTALLATION DETAILS
HYTP-036 HYBA-084
FQCW-018
FQCW-018
HYTP-036 HYBA-085
11. AV EQUIPMENT & ASSOCIATED SERVICES ARE INDICATIVE ONLY, REFER TO ICT BRIEF AND ICT CONSULTANTS DOCUMENTS FOR DETAILS.
F I D I -0 3 0
F I D I -0 2 5
12. REFER ELECTRICAL DOCUMENTS FOR FINAL SPECIFICATIONS OF ELECTRICAL OUTLETS.
INDICATIVE WALL LEDGE REFER A12 FOR WALL TYPE DETAIL
13. REFER TO A14-SERIES FOR OVERVIEW OF ROOM LAYOUTS.
H Y T P -0 3 6 H Y B A -0 7 9
HYTP-035
14. REFER A96-0006 SANITARY SCHEDULE FOR SPECIFICATIONS OF SANITARY FITTINGS. FQCW-018
HWC-06L-A Handwash Facility Type C Public/Staff Handwash with accessible lever tap, mini basin, left side tap
LT-06 FQCW-018
HYTP-036 HYBA-079
A10 B10
15. REFER A96-0003 SERIES FOR FF&E SCHEDULE FOR SPECIFICATION OF FF&E ITEMS.
HWC-05 Handwash Facility Type C Parent Shower Room Handwash with standard lever tap, right shelf
FIDI-030
FIDI-025
F Q C W- 0 1 8
FIBM-022
HYTP-035 HYBA-085
FQCW-018
L T -0 6
HYBA-084
FQCW-018
FIDI-030
FIDI-025
FIDI-025
FIDI-030
FIDI-030 HYTP-035 HYBA-084
FQCW-018
FIDI-030
HYTP-035 HYBA-085
FQCW-018
FIBM-022
FIBM-022
FIDI-025
FQCW-018
FIBM-022
ALIGN SIDE EDGE OF FIBM-022 TO SIDE EDGE OF HYBA-084
45
FIDI-030
HYTP-036 HYBA-085
485
FIDI-030
FIDI-025
FIDI-025
FIDI-025
FIBM-022
FQCW-018
INDICATIVE WALL LEDGE REFER A12 FOR WALL TYPE DETAIL
HWB-08R Handwash Facility Type C 2 Bed Paediatric 50
FIBM-023
FIBM-023 300
80 590
FQCW-018 HYTP-035 HYBA-079 FQCW-018 FIDI-030
HYTP-035 HYBA-078 FIDI-030 FIDI-025
100
FFL 450
HYWC-006
300
300
MAX.
MAX.
HYWC-006 FIDI-036
FIDI-037
HYWC-002
HYWC-006
450
WCF-04L Toilet facility - ensuites
FIHR-083
DASHED LINES INDICATING STEEL COLUMN SUPPORT REFER STRUCTURAL ENGINEER'S DRAWING FOR SECONDARY SUPPORT DETAILS
ITCL-037
F I H R -0 8 3 700 MAX.
F I H R -0 8 3 ITCL-037 FIDI-036
0
230
FIRT-008.1
100
FIRT-009
230
WCF-03 Toilet facility - staff & public toilets
HYWC-005
515
330
PATIENT ENSUITE
VARIES
FIHR-083 FIRT-051
CONTRACTOR TO ENSURE 50mm FROM EDGE OF BASIN TO WALL FACE U.N.O.
2700FCL
HYWC-005
HYWC-017 FIDI-036
FIDI-030
FIDI-025 FIDI-030 50
REFER A12 FOR WALL SET-OUT
WCF-02 Toilet faciltiy - ambulant toilets
FIRT-050
480
HWB-08L Handwash Facility Type C 1 Bed Isolation Paediatric
FIBM-023
1000. 800 . 700 . 600 .
300 MAX.
50
FQCW-018
HWB-07R [Handwash Facility]
FIRT-006
EQ
ALIGN TO EDGE OF BASIN
HYTP-035 HYBA-079
FQCW-018
700 MAX.
EQ
INDICATIVE SIDE WALL
INDICATIVE SIDE WALL
SET-OUT FOR BOTH FIRT-050 & FIRT-051
FIRT-048
HYWC-001 FIDI-036
ITCL-037
50
CONTRACTOR TO ENSURE 50mm FROM EDGE OF BASIN TO WALL FACE U.N.O.
HYTP-035 HYBA-081FQCW-018
FIDI-037
FIDI-036
WCF-01R Toilet faciltiy - accessible toilets Right hand grab rail
FIHR-083
FIBM-023 HYTP-035 HYBA-078
JSR1-A
HYTP-035 FQCW-018HYBA-080
700 MAX.
FIRT-051 HYWC-017
900 -920
FIBM-023
515
FIBM-023
CLEAR
NURSE CALL ADDITION TO TOILET FACILITY IN PATIENT ENSUITES
FIDI-030
HWB-07L [Handwash Facility] Paediatric Patient Ensuite
50
FIHR-083
FIRT-050
FIRT-048
450
FIRT-048 NURSE CALL ADDITION TO TOILET FACILITY IN PATIENT ENSUITES
ALIGN TO EDGE OF BASIN
FQCW-018
FIDI-030
LT-06
515
50
WALL-RECESSED SHELVING REFER A60 FOR DETAILS
FIBM-023
HYTP-035 HYBA-081
FQCW-018
HYTP-035 HYBA-081 FQCW-018
200-250
474
HYWC-001
800
FFL
250
300 MAX.
EQ
900
300 MAX.
HYTP-035 HYBA-080
FIRT-008
0
515
300
FIBM-023
ALIGN TO EDGE OF BASIN
HWB-06R [Handwash Facility]
ALTERNATIVE LOCATION IN 1 BED BARIATRIC ENSUITE
900 - 920
380
WCF-04R Toilet faciltiy - ensuites
FIHR-083 FIRT-006
FIHR-083 FIRT-009
ITCL-037
ITCL-037
380
WCF-05 Toilet facility - ensuites (special bariatric)
FIRT-008.1
FIRT-008 ITCL-037
HYWC-006 FIDI-036
HYWC-002
CLEAR
FIRT-044
FIHR-026
ELEVATION B
HYTP-039
2700FCL
2100.
HYTP-039
1000. 900 . 800 . 600 .
FIRT-046
0
1:60
L
HYTP-020 FIRT-046 HYTP-039
250
500
150200
HYDR-004 1:60
TO
200
FIDI-049 FIRT-046
ITCL-037 HYTP-039 FIRT-046 HYTP-020
HYTP-020 FIRT-047 HYTP-039
1:80
FQGE-011 FIRT-034
A
200
HYTP-039 HYTP-020
1:80 TO 1:100 FALL TO REMAINING FLOOR AREA OF SANITARY ROOM
500
HYTP-039 FIDI-049 HYTP-020 FIRT-047
HYDR-004
L
600 TO WALL FACE
1200
1:80 TO 1:100 FALL TO REMAINING FLOOR AREA OF SANITARY ROOM
1:80 TO 1:100 FALL TO REMAINING FLOOR AREA OF SANITARY ROOM
MIN. CLEAR
*REFER A14 DRAWING SERIES FOR LOCATION OF ITCL-037 (WET AREA NURSE CALL BUTTON)
1200
PROJECT ARCHITECT:
HYBA-021
HYDR-004
DRAIN - REFER A11 FOR FLOOR WASTE SET OUT 1:100 FALL TO REMAINING FLOOR AREA OF SANITARY ROOM
DRAWN BY
DS REGISTRATION NO.
HYDR-004
600 TO WALL FACE
CHECKED BY
IZ PROJECT NO.
REVISION DATE
19073
DRAWING NO
SCALE
1 : 50 @ A0
A80-0002
REVISION NUMBER
[C1]
FOR CONSTRUCTION
1:54:19 PM _LAST29/07/2021 ACCESSED:
ENSUITE ROOM BOUNDARY INDICATION REFER A12 FOR WALL SET OUT DETAILS
B FAL
ROOM BOUNDARY LINE INDICATIVE - REFER A12 FOR WALL SET OUT DETAILS
L
ENSUITE ROOM BOUNDARY INDICATION REFER A12 FOR WALL SET OUT DETAILS
FIDI-049
550
FQGE-011 FIRT-034
1800
FAL
KIT OF PARTS SANITARYWARE SETS
SHW-04L Shower Facility Ensuite - Bariatric With left hand grab rail*
FAL
1:80 TO 1:100 FALL TO REMAINING FLOOR AREA OF SANITARY ROOM
1:80
LATROBE REGIONAL HOSPITAL - STAGE 3A
FFL
300 250
00
ENSUITE ROOM BOUNDARY INDICATION REFER A12 FOR WALL SET OUT DETAILS
1:80 TO 1:100 FALL TO REMAINING FLOOR AREA OF SANITARY ROOM
TO
PROJECT NAME
1:1
1:80 TO 1:100 FALL TO REMAINING FLOOR AREA OF SANITARY ROOM
550
HYTP-039 ITCL-037 HYTP-020 FIRT-047 HYDR-004
B
1200
A
FIHR-026 FIRT-045
300
SHW-04R Shower Facility Ensuite - Bariatric With right hand grab rail*
1750
300 200
250
HYTP-039 FIDI-049 HYTP-020 HYDR-004 ITCL-037
B
1700.
1000. 900 . 800 . 600 .
FIDI-049
FIRT-047
FFL
SHW-03L Birthing Ensuite Left corner wall placement
200 350
A
HYTP-039
FIRT-046
CLIENT
2100.
SHEET NAME
0 SHW-03R Birthing Ensuite Right corner wall placement
1200
A
HYTP-039
FIDI-049
DASHED LINES INDICATING STEEL COLUMN SUPPORT REFER STRUCTURAL ENGINEER'S DRAWING FOR SECONDARY SUPPORT DETAILS
HYTP-020
ITCL-037
FFL
250
200 350
B
DASHED LINES INDICATING STEEL COLUMN SUPPORT REFER STRUCTURAL ENGINEER'S DRAWING FOR SECONDARY SUPPORT DETAILS
HYTP-020
1700.
FIDI-049 FIRT-047
ITCL-037
0
BATH ROOM PAEDIATRIC (04-029)
2700FCL
FIRT-034 HYTP-020
1750
0
550 1100
350
900
HYTP-039
FIRT-046
ELEVATION A
FIRT-034 FQGE-011 HYTP-020
1:80 TO L 1:60 FAL
ENSUITE ROOM BOUNDARY INDICATION REFER A12 FOR WALL SET OUT DETAILS
FIDI-049
FIRT-047
FIRT-034 FQGE-011
1:80 TO L 1:60 FAL
1:80 TO 1:100 FALL TO REMAINING FLOOR AREA OF SANITARY ROOM
HYTP-039
1000. 900 . 800 . 600 .
0
0
1:80 TO 1:100 FALL TO REMAINING FLOOR AREA OF SANITARY ROOM
HYTP-020
_DOCUMENT NUMBER: 19073-A80-0002- [C1]
0
350 200
FIDI-049 HYTP-039 FQGE-011 HYTP-020 FIRT-034 HYDR-004 ITCL-037 FIHR-026 FIRT-044
1:8 TO LL FA
1:8 TO LL FA
FQGE-011 FIRT-034 FIHR-026
0
0 FA TO LL 1:8
250
FIGE-001 FIHR-026
FIHR-026
FIHR-026 ENSUITE ROOM BOUNDARY INDICATION REFER A12 FOR WALL SET OUT DETAILS
350
1100
147 250
B
HYTP-020
1160
1:6
0
A
400
NURSE CALL ADDITION TO SHOWER FACILITY ITCL-037 IN PATIENT ENSUITES
1:6
A
ELEVATION B
FIRT-034
1700.
350
1160
FIDI-047 HYTP-039 FIRT-046 HYTP-020 HYDR-004
B
FIRT-045
2100.
23/07/2021 DATE
Level 20/485 LaTrobe Street Melbourne 3000 Victoria, Australia T +61 3 9656 5000 Billard LeeceE info@blp.com.au Partnership www.blp.com.au
N
900
ITCL-037
FIDI-047 FIRT-047 HYTP-020 HYDR-004
FIDI-049 FIRT-045
ELEVATION A
2700FCL
SHW-02L Patient Ensuite Right hand return grab rail
200
250 200
FIGE-001 FIHR-026
HYTP-039
SHW-02R Patient Ensuite Left hand return grab rail
1160
1:6
350
HYTP-039
FQGE-011 FIRT-034 FIHR-026
HYTP-039
FIRT-044
SHW-01L DDA Compliant Shower Right hand grab rail 1160
FIDI-049
FIRT-034
350
FFL
ELEVATION B
HYTP-020
FIDI-049
0
FIRT-034 FQGE-011
ITCL-037
1000. 900 . 800 . 600 .
ELEVATION A
FIRT-034 FQGE-011
1102
FIGE-001
HYTP-020
552
FIHR-026
HYTP-039
ELEVATION B
FIRT-034
0 FA TO LL 1:8
FIRT-046 ITCL-037
BARIATRIC ENSUITE
BIRTHING ENSUITE
ELEVATION A
1:6
FIDI-047
FIRT-047 ITCL-037
FIHR-026
FIDI-047
2100. 1700.
FIHR-026
FIHR-026 FIHR-026
FIHR-026
HYTP-039
FIGE-001
SHW-01R DDA Compliant Shower Left hand grab rail
1100
FFL
400
0
200
1200. 1000. 800 . 600 .
2700FCL HOOK ADDITION FOR IV FLUID BAG IN PATIENT ENSUITES
FIRT-034 FQGE-011
HYTP-020
350
ELEVATION B
FIRT-034
FIHR-026
ELEVATION A
FIRT-034 HYTP-020
1800
PATIENT ENSUITE
ELEVATION A
FIRT-034 FQGE-011
1700.
ITCL-037
ELEVATION B
HOOK ADDITION FOR IV FLUID BAG IN PATIENT ENSUITES
2100.
C1 FOR CONSTRUCTION REV AMENDMENTS
300
SANITARY SETS - SHOWERS COMPLIANT DDA COMPLIANT AS1428.1 SHOWER FACILITY 2700FCL
7. REFER TO A14 SERIES FFE DRAWINGS FOR SETOUT OF SPECIFIC ITEMS IF NOT INDICATED IN THIS DRAWING. 8. FFE ITEMS SHOWN IN THIS DRAWING ARE INDICATIVE ONLY, SHOWN FOR PLANNING PURPOSES AND SERVICES COORDINATION ONLY, REFER ALSO TO DOCUMENTS OF FFE CONSULTANT.
HYTP-052 HYTP-037 HYBA-010 FQCW-018
A6 C6 B6
40
FIDI-025
FIDI-030
FIDI-030
FIDI-030
40
MIN.
700 MAX.
700 MAX.
ITCL-037 FIDI-036
F I H R -0 8 3 FIRT-048 FIDI-036
FIRT-049
NURSE CALL ADDITION TO TOILET FACILITY IN PATIENT ENSUITES
WCF-01L Toilet faciltiy - accessible toilets Left hand grab rail
FIRT-049 FIHR-083
FIDI-025
WL-01 FIDI-031 FIDI-030
FIDI-022
A5 C5
40
ALIGN SIDE EDGE OF FIBM-022 TO SIDE EDGE OF HYBA-084
FQCW-018
715
LT-06
HYTP-035 HYBA-080 FQCW-018
450
ITCL-037
500 NOM.
HWB-04 Handwash Facility Type B Concealed dispensers in overhead joinery
HYBA-010
HYTP-037 HYBA-010
HWC-04L-A HWC-04L HWC-04R HWC-04R-A Handwash Facility Type C Handwash Facility Type C Handwash Facility Type C Handwash Facility Type C Public/Staff Handwash with extended lever Public/Staff Handwash with standard lever Public/Staff Handwash with standard lever Public/Staff Handwash with extended lever tap, mini basin, left side tap, ambulant toilettap, mini basin, left side tap tap, mini basin, right side tap tap, mini basin, right side tap, ambulant toilet
300
FQCW-018
EQ
HYWC-001 FIDI-036
600 NOM. SIDE VINYL
HWB-03 Handwash Facility Type B Alcove wall placement
4. ANTISEPTIC SOAP DISPENSER ALWAYS ON LEFT HAND SIDE, 4. ALL DIMENSIONS SHALL BE VERIFIED ON SITE REGULAR SOAP ALWAYS ON RIGHT HAND SIDE, REGARDLESS OF BEFORE PROCEEDING WITH THE WORK. RELEVANT LOCATION OF OTHER DISPENSERS. PARTY SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES. 5. TOILET PAPER DISPENSER MUST BE INSTALLED CLEAR OF DOOR SWINGS. 5. THE MANUFACTURER SHALL NOT COMMENCE ANY
JSR1-A
HYBA-081
SANITARY SETS - TOILETS COMPLIANT PUBLIC/PATIENT TOILETSAS1428.1 TOILET FACILITY
480
HYTP-035 HYBA-084
FFL
FIBM-022
WALL-RECESSED SHELVING REFER A60 FOR DETAILS
1100. 900 .
ALIGN TO EDGE OF BASIN
2700FCL
FIRT-049
FQCW-018
FQCW-018
FQCW-018 FIDI-014
FIDI-022
B4
FIBM-022
300
300 850
JSR1-A
300
JSR1-A
JSR1-A
FIDI-030
50
FIRT-016 FIDI-025
800
OVERHEAD & UNDERBENCH JOINERY REFER A14 FFE DRAWING FOR SPECIAL JOINERY TYPE & A61 SPECIAL JOINERY DRAWING FOR DETAILS
HYBA-086
NOTED OTHERWISE. 3. REFER TO A96-0006 SANITARY FIXTURES SCHEDULE & SPECIFICATION FOR TYPE/ COLOUR AND FINISHES OF FIXTURES &3. ALL DIMENSIONS ARE TO THE FINISH FACE OF WALL FITTINGS UNLESS NOTED OTHERWISE.
FIDI-036 ITCL-037
HYBA-080
HWB-06L [Handwash Facility]
50
HYWC-001 450
0
FIDI-030
FIDI-030
FIDI-030 HYTP-035
715
515
LT-06FIDI-030
FQCW-018HYTP-035 HYBA-079
FIRT-016 FIDI-025
LT-06
HYTP-035
FQCW-018
HWB-05R [Handwash Facility]
515
FIRT-049
500 MIN.
REAR VINYL
HWB-02R Handwash Facility Type B Corner wall placement, Right hand approach
FIDI-025
500 MIN.
1000 NOM.
1000 REAR VINYL
40
FIDI-030
FQCW-018
FFL
600 NOM. SIDE VINYL
600 SIDE VINYL
40
ALIGN SIDE EDGE HYTP-036 OF FIBM-022 TO HYBA-084 SIDE EDGE OF HYBA-084
JSR1-A
HYBA-079
FIDI-030LT-06 300
LT-06
50
FIDI-030
HYBA-078
50
0
500 MIN. 600 NOM. SIDE VINYL
HYTP-037 HYBA-010
OVERHEAD JOINERY & GLOVE DISPENSER TO SPLASHBACK BE MOUNTED ON REFER A61 SPECIAL INSIDE FACE OF JOINERY DRAWING FOR CUPBOARD, REFER TO DETAILS A60 SERIES FOR HYTP-037 DETAILS HYTP-052
HYBA-010
FQCW-018
HYBA-079
ALIGN CENTRE OF MIRROR TO CENTRE OF TAP CONTRACTOR TO ENSURE 50mm FROM EDGE OF BASIN TO WALL FACE U.N.O.
715
ALTERNATIVE LOCATION IN 1 BED BARIATRIC ENSUITE
FIDI-030
HYTP-035
F I H R -0 8 3 FIRT-049
40
FIDI-025
FIDI-030
FIBM-023 HYTP-036
HYBA-079
715
50
ALIGN TO EDGE OF BASIN
HYTP-035
FQCW-018
850
ALIGN CENTRE OF MIRROR TO CENTRE OF TAP CONTRACTOR TO ENSURE 50mm FROM EDGE OF BASIN TO WALL FACE U.N.O.
FIDI-030
LT-06
1100.
100
830 .
FIDI-025
FIBM-023 HYTP-035
FIDI-030
FIDI-030
FIBM-023 HYTP-036
FIDI-030
LT-06
CONTRACTOR TO ENSURE 50mm FROM EDGE OF BASIN TO WALL FACE U.N.O.
FIDI-030
FIDI-030
50
FIDI-030
515
HYTP-035FQCW-018 HYBA-078
FIDI-014
GLOVE DISPENSER TO BE MOUNTED ON INSIDE FACE OF CUPBOARD, REFER TO A60 SERIES FOR DETAILS
40 40
TYPE C - PAEDIATRIC PATIENT ENSUITE
515
1000. 800 . 600 . 480 .
A4
FIBM-022
FQCW-018
FIDI-025
FIBM-023 HYTP-035 HYBA-078
HWB-05L [Handwash Facility]
HYBA-010
1000 NOM.
FQCW-018
40
1100.
HYTP-036 HYBA-079
FQCW-018
FQCW-018
40
FIDI-025
FIDI-030
FIBM-023
FIDI-025
FIDI-030
FIDI-025
FIBM-023
FIBM-023
HYTP-035 HYBA-079
FIDI-030
FIDI-025
FQCW-018
50
FFL
500 MIN.
HYTP-037 HYBA-010 FQCW-018
45 45
SANITARY SETS - HANDWASH BASINS TYPE C - IPU PATIENT ENSUITE
0
FIDI-014
FQCW-018
HWC-03L-A HWC-03L HWC-03R-A HWC-03R Handwash Facility Type C Handwash Facility Type C Handwash Facility Type C Handwash Facility Type C Public/Staff handwash facility with extendedPublic/Staff Handwash with standard lever Public/Staff Handwash with extended lever Public/Staff Handwash with standard lever tap, right shelf lever tap, left shelf, ambulant toilet tap, left shelf tap, right shelf, ambulant toilet
FQCW-018
830 .
HYTP-037
40 50
EQ EQ 45 45
HYTP-036 HYBA-078
FQCW-018
FIDI-025
FIDI-030
HYTP-035
HYTP-035
FIDI-025
FIDI-030
FIDI-030
HYTP-035 HYBA-078
FFL
HYBA-079
CONTRACTOR TO ENSURE 50mm FROM EDGE OF BASIN TO WALL FACE U.N.O.
HYTP-037
REAR VINYL
HWB-02L Handwash Facility Type B Corner wall placement, Left hand approach
FIDI-025
0
HWC-02L HWC-02R Handwash Facility Type C Handwash Facility Type C Public/Patient Handwash Facility Left hand Public/Patient Handwash Facility Right hand appraoch approach
HYBA-078
FIBM-023
830 .
FQCW-018
FQCW-018
WL-01
ELEVATION B10 ELEVATION A10 EQ EQ
45 45
FIDI-025
FQCW-018
FIDI-025
FIDI-030
INDICATIVE SIDE WALL
FIDI-030
FIDI-025
1100.
HYTP-035 HYBA-079
HYTP-035 HYBA-078
FFL
500 MIN.
1000 NOM. REAR VINYL
HWB-01 Handwash Facility Type B Straight wall placement
HYBA-009
EQ EQ
45 45
FIBM-023
ELEVATION C6
40 40 40
HYBA-010
FQCW-018
FQCW-018
500 MIN.
1000 NOM.
A3 C3 B3
EQ EQ
65 65
MIN.
FIBM-023
ELEVATION A6
WL-01
WL-01
WL-01
FFL
TYPE C - PUBLIC/STAFF TOILET 450
ELEVATION C6
40 40
PUBLIC/STAFF TOILET MINI BASIN
FIDI-030
0
FIDI-025
1100. 900 . 830 DDA
INDICATIVE SIDE WALL
450 MIN.
HYBA-010
REAR VINYL
HYTP-037
ELEVATION A5
WL-01
FQCW-018
0
SANITARY SETS - HANDWASH BASINS AS1428.1 COMPLIANT TYPE C - DDA COMPLIANT HANDWASH FACILITY 65 65
FIDI-025
FIDI-030 FIDI-031
FIDI-025
500 MIN.
480
WL-01
HYBA-010
HWA-04 Handwash Facility Type A Concealed dispensers in overhead joinery
FQCW-018
HYTP-037 HYBA-009
A2 C2
500 MIN.
ELEVATION C5
WL-01
FIDI-031
600 NOM. SIDE VINYL
FIDI-014
FIDI-025
FIDI-031 FIDI-030
FIDI-031 FIDI-030
FQCW-018 FIDI-025
B1
MIN.
1000 NOM. REAR VINYL
HWA-03 Handwash Facility Type A Alcove wall placement
ELEVATION C4
485
HYTP-037
HYTP-037
1000. 865 .
FQCW-018
WL-01
40 40
WL-01
FIDI-030
600 NOM. SIDE VINYL
FIDI-014
FIDI-025
FIDI-031 FIDI-030
FIDI-014
1000 NOM. REAR VINYL
HWA-02R Handwash Facility Type A Corner wall placement, Right hand approach
HYBA-009
500
MIN.
600 NOM. SIDE VINYL
HYTP-037
A1
500
MIN. 600 NOM. SIDE VINYL
HYTP-037 HYBA-009 FQCW-018
FQCW-018
500
MIN. 1000 NOM. REAR VINYL
HWA-02L Handwash Facility Type A Straight wall placement
1300.
HYBA-009
WL-01 FQCW-018
OVERHEAD JOINERY & SPLASHBACK REFER A61 SPECIAL JOINERY DRAWING FOR DETAILS HYTP-037
ELEVATION A4
40
FIDI-014 FIDI-031 FIDI-030
500
1000 NOM. REAR VINYL
HWA-01 Handwash Facility Type A Straight wall placement
INDICATIVE SIDE WALL
FIDI-014
WL-01
40
FIDI-030 FIDI-025
FQCW-018
HYBA-009
40
2700FCL
FIDI-014 FIDI-031
FQCW-018
WL-01
FFL
FIDI-014
GLOVE DISPENSER TO BE MOUNTED ON INSIDE FACE OF CUPBOARD, REFER A60 SERIES FOR DETAIL
HYTP-037
HYBA-009
1250
HYBA-009
FIDI-031 FIDI-030
FIDI-025
FIDI-031 FIDI-030
FIDI-014
WL-01
150
HYTP-037
HYBA-009
ELEVATION C3
40 40 40
HYTP-037
HYTP-037
WL-01
0
FIDI-031 FIDI-030
FIDI-014
1000. 865 .
FIDI-025
FIDI-014
FIDI-031 FIDI-030
FIDI-025
1300.
ELEVATION A3
WL-01
INDICATIVE SIDE WALL
40
FIDI-025
40
WL-01
FIDI-030 FIDI-031
ELEVATION B3
ELEVATION A2
480
WL-01
FIDI-014
ELEVATION B2
485
FIDI-025
ELEVATION B1
40 40
GENERAL NOTES:
1. FIXTURES, FITTINGS AND SET OUTS TO COMPLY WITH AS 1428.1 1. CONTRACTORS AND THEIR ASSOCIATES SHALL VERIFY ALL DIMENSIONS OF THIS DRAWING AND SITE 2. NURSE CALL BUTTON SHOWN IS TYPICAL ARRANGEMENT. READ IN CONDITIONS PRIOR TO ANY WORK COMMENCING. CONJUNCTION WITH A14 SERIES DUE TO VARIATIONS OF MOUNTING HEIGHT 2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
TYPE B - CLINICAL BASIN ELEVATION A1
40
FIDI-031 FIDI-030
40
FIDI-025
40
C:\Users\fionam\Documents\19073_LRH3A_KoP_R19_fionamEK3GH.rvt
NOTES:
SANITARY SETS - HANDWASH BASINS TYPE A - SCRUB BASIN 2700FCL
Excerpt from architectural drawing set / Revit 11
Project: Jordan Springs Primary School, NSW
WORK EXPERIENCES
Involvement: Key person in documenting 4 buildings of a primary school project in an interstate office team for design development package working towards Significant State Development
Architectural Graduate at Hayball
Application issue.
FLOOR PLAN GENERAL
ALL FFE AND ICT LAYOUTS ARE INDIC REFER TO DOCUMENTATION FOR AL
REFER ACCOMPANYING CONSULTAN DRAWINGS AND REPORTS FOR STRU SERVICES, LANDSCAPE AND OTHER REQUIREMENTS.
2
.A06.01
.A06.02
B01
B02
REFER SHEET 02.A00.00 FOR ROOM F
3
B03
B04
B05
REFER 2141.02_TECHNICAL REFEREN SCHEDULE FOR EXTERNAL MATERIA FIXTURES, DOORS, WINDOWS, CEILIN FENCES, GATES AND SIGNAGE
B06
33640 7400
7500
7500
4000
7240
LEGEND AMENITIES ENCLOSABLE LEARNING SPACE
WE.06
B0A
DT-28
WE.01b
DT-28
WE.06
WE.01b
WE.01b
WE.06
OPEN LEARNING SPACE
N
DT-28
OUTDOOR CIRCULATION OUTDOOR LEARNING SPACE STORE
KEY PLAN B02A 4000
BUILDING DISTRIBUTOR 10.5 m²
DT-03h
B0B LEARNING STUDIO 60.1 m²
LEARNING STUDIO 60.3 m²
LEARNING STUDIO 59.9 m²
LEARNING STUDIO 58.3 m²
DT-14 4500
SMALL LEARNING 20.2 m²
DT-14 WE.08
2000
UP
LEVEL 1 LINE ABOVE
DT-14
B0C 19500
DT-14
DT-14 DT-14
2
DT-14 DT-03b
.A06.01
1 .A06.01
B0D PRACTICAL ACTIVITIES AREA 60.8 m²
WE.08
6500
LEARNING STUDIO 60.3 m²
FFL 40.50 WE.04
WE.08
LEARNING COMMON 64.1 m²
DT-03a
FFL 40.50
FFL 40.50
COVERED OUTDOOR LEARNING AREA
OPEN LEARNING STUDIO + PRACTICAL ACTIVITIES AREA 62.6 m²
MEDIUM LEARNING SPACE 25.9 m²
L AL W
264.2 m²
E LIN
DT-03b
B0E 2500
WE.04
AMBULANT WC 2.4 m²
B0F DT-01a
WC 2.7 m²
WC 2.6 m²
WC 2.6 m²
WC 2.7 m²
DT-01a
DT-01a
DT-01a
DT-01a
EDB 1.3 m²
SSDA ISSUE SSDA ISSUE PRELIMINARY SSDA ISSUE
Rev
Description
STATE SIGNIFICANT DEVELOPMENT APP
DT-03b WE.01e
BLOCK B02A
WE.01d
WE.01c
BLOCK B02B
OUTDOOR CIRCULATION 35.7 m²
STAIR 4
REFER B02B.A03.01 SHEET
UP
Melbourne 4/135 Sturt Street Southbank,Victoria Austra T 0+61 3 9699 3644 www.hayball.com.au
L VE
CLIMB-01
1L
LOUV RE LEVEL D SCREEN 1 ABOV CONTI NUES E TO
VE BO EA IN
LEVEL 1 LINE ABOVE
3 2 1
DT-03b
LE
Sydney Ground Floor, 11-17 Buckingham Street, Su T +61 2 9660 9329
W L AL E LIN
4
.A06.01
EEN SCR VE ED BO VR LOU L 1 A LEVE
STAIR 3
UES NTIN CO TO
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
.A06.02
12
REFER TO LANDSCAPE ARCHITECT'S DRAWINGS
DT-12 DT-03b
1
CLIMB-01
Brisbane Level 12, 324 Queen Street, Brisbane Qld 4 T +61 7 3211 9821
NSW Nominated Architects: Tom Jordan 7521, Richard Leonard 7522, D 8028 ABN 84 006 394 261
Excerpt from architectural drawing set / Revit UP
Builders/Contractors shall verify job dimensions before any job commenc precedence over scaled work. Work shall also conform to the specificati dimensions. All shop drawings shall be submitted to the Architect/Consu commence prior to the return of inspected shop drawings signed by the A 2008 All rights reserved
Client:
REFER TO LANDSCAPE ARCHITECT'S DRAWINGS
PROPOSED SITE PLAN GENERAL NOTES CONTOURS SHOW APPROXIMATE SITE LEVELS; REFER TO CIVIL/SURVEY FOR EXISTING INFRASTRUCTURE, UTILITIES, AND TOPOGRAPHY.
CRIMSON ST 44
SITE BOUNDARY
43.5
REFER TO CIVIL/SURVEY DRAWINGS FOR EXISTING INFRASTRUCTURE + UTILITIES ETC.
43 43
40208
SETBACK
PROVIDE EMERGENCY ACCESS EASEMENT AS INDICATED. REFER BUSHFIRE REPORT. REFER SERVICES FOR SITE INFRASTRUCTURE.
42.5 42.5
10m DEFENDABLE
LAKESIDE PARADE
CONTRACTOR TO UNDERTAKE SITE SURVEY PRIOR TO COMMENCING WORKS TO CONFIRM SITE BOUNDARY & CONTOURS.
SITE BOUNDARY
44
43.5
EMERGENCY ACCESS GATE 1
2
A01.14
PROPOSED SCHOOL BUS STOP
42 42
41
.5
STAIR 5
3B
39.5
VEHICLE ENTRY 1& 2 - AUTOMATED SLIDING GATE-01 WITH ACCESS CONTROL
LP
BOUNDARY LINE A01.10
SMH NOT VISIBLE
6
STAFF PARKING (59No)
BLOCK B02B 14 TEACHING SPACES
40.5
SPORTS COURT
5 1041 ACK SETB
SIT E
DE ND FE
4 .7 40 41
SITE BOUNDARY
LE AB
STAIR 2 40
SP AC E
COVERED WALKWAY
.R
EF E
R
TO
BO UN DA RY
1B
A01.14
PITT ST
BLOCK A LIBRARY, ADMIN, STAFF
H
6100 SETBACK
PEDESTRIAN ENTRY 3
A01.14
2No. STOREYS
EMERGENCY ACCESS GATE 2
Melbourne 4/135 Sturt Street Southbank,Victoria Australia 3006 T 0+61 3 9699 3644 www.hayball.com.au
Brisbane Level 12, 324 Queen Street, Brisbane Qld 4000 T +61 7 3211 9821
AY
NSW Nominated Architects: Tom Jordan 7521, Richard Leonard 7522, David Tordoff 8028 ABN 84 006 394 261
3C
A01.14
H
SM
2
7700
.0 TE 7 L
Client:
40
H
COVERED BICYCLE PARKING
2
A01.14
VEHICLE ENTRY 2 STAFF/REFUSE
Builders/Contractors shall verify job dimensions before any job commences. Figured dimensions shall take precedence over scaled work. Work shall also conform to the specification, other drawings and job dimensions. All shop drawings shall be submitted to the Architect/Consultant and manufacture shall not commence prior to the return of inspected shop drawings signed by the Architect/Consultant. © Copyright 2008 All rights reserved
10 A01.
40
ZONE FOR BOOSTER, GAS & WATER METERS 7000
INDICATIVE ZONE FOR NEW SUBSTATION. FENCING & GATES TO BE COORDINATED WITH ELECTRICAL PROVIDER.
FB OF
PEDESTRIAN ENTRY 2
7000
SM
EXISTING CHILD CARE
2400 2400
1No. STOREY
BINS
OP DR
PROPOSED SUBSTATION
2400
MSB
EXISTING COMMUNITY HUB
Date
Sydney 11-17 Buckingham Street Surry Hills, NSW 2010 T +61 2 9660 9329
BLOCK C SCHOOL HALL
1
02/11/2018 26/10/2018 22/10/2018 24/10/2018
Description
1
COVERED ENTRY
SM
SITE BOUNDARY
T OR
AIR
SSDA ISSUE SSDA ISSUE DWG ISSUE PRELIMINARY SSDA ISSUE
Rev
EXISTING BUS STOP
5 39.
P RE
ST COVERED WALKWAY
4 3 1 2
STATE SIGNIFICANT DEVELOPMENT APPLICATION
BU S RAINWATER HFIR E GARDEN
EXISTING CARPARK
CULLEN AVE
ACCESS TO CREEK
10m
AUTO SLIDING GATE
REFER TO LANDSCAPE PLANS FOR FURTHER SITE DETAILS
EXISTING CARPARK
LAKESIDE PARADE
ACCESS TO CREEK
LEGEND STAIR 3
EXISTING SUBSTATION
WATER GUM DR
PEDESTRIAN ENTRY 1,2 & 3 - SLIDING GATE-02 AND SIDE HINGED GATE-05 WITH ACCESS CONTROL
39.5
A01.14
COVERED PEDESTRIAN ENTRY 1 & BICYCLE PARKING
VEHICLE ENTRY 1 STAFF
NORTHERN BOUNDARY FENCE FN03. BOUNDARY FENCE FN-02 TO ENTIRE REMAINING PERIMETER. GATES TO MATCH FENCING.
K EE CR
STAIR 4
EXISTING BUS STOP
FENCING
REPORT TO BUSHFIRE
BLOCK B02A 12 TEACHING SPACES
41.5
LANDSBOROUGH ST
DROP OFF BAY BY CONTRACTOR IN CONSULTATION WITH LOCAL COUNCIL.
SPACE. REFER
PLAYING FIELD
PROPOSED INTEGRATED HOUSING/ TOWNHOUSES 3No. STOREYS
1
Jordan Springs Public School
A01.10
14-28 Cullen Avenue, Jordan Springs, NSW 2747
TTE ST
5No. STOREYS
CHARLO
PROPOSED MULTI-RESIDENTIAL
PROPOSED INTEGRATED HOUSING/ TOWNHOUSES 3No. STOREYS
DRAWINGTITLE
PROPOSED SITE PLAN
REET
NK DRAWN BY DT CHECKED DATE PRINTED 05-Nov-18 4:36:36 PM 1 : 500@A1 SCALE
PROJECT NUMBER DWG NO
2141.02 S02. A01.02
N REVISION
4
Excerpt from architectural drawing set / Revit 13
COVERED WALKWAY
ADMIN / LIBRARY BLOCK A
RL. 40.000
1 A01.02
RAINWATER GARDEN RL. 38.962
SITE SECTION 1 1 : 200
HALL BLOCK H
14
2
SITE SECTION 2 1 : 200
3 2 1
SSDA ISSUE SSDA ISSUE PRELIMINARY SSDA ISSUE
Rev
Description
HOMEBASE BLOCK B
RL. 44.000
COVERED WALKWAY
SITE BOUNDARY
STATE SIGNIFICA DEVELOPMENT A
SITE BOUNDARY
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
HOMEBASE BLOCK B
A01.02
SITE BOUNDARY
HALL BLOCK H
10m EMERGENCY ACCESS BUFER ZONE
SITE BOUNDARY
CHILDCARE CENTRE
10000
ADMIN / LIBRARY BLOCK A
Melbourne 4/135 Sturt Street Southbank,Victoria A T 0+61 3 9699 3644 www.hayball.com.au
Sydney 11-17 Buckingham Street Surry Hills, N T +61 2 9660 9329 RL. 44.000
RL. 40.500 RL. 40.000
Brisbane Level 12, 324 Queen Street, Brisbane Q T +61 7 3211 9821
NSW Nominated Architects: Tom Jordan 7521, Richard Leonard 752 8028 ABN 84 006 394 261
Builders/Contractors shall verify job dimensions before any job co precedence over scaled work. Work shall also conform to the sp dimensions. All shop drawings shall be submitted to the Architec commence prior to the return of inspected shop drawings signed 2008 All rights reserved
Client:
3
SITE SECTION 3 1 : 200
Excerpt from architectural drawing set / Revit Jordan Springs Public
14-28 Cullen Avenue, Jordan Springs, N
DRAWINGTITLE
GENERAL ELEV A06 RF-02
AL-03
ROOF
AHD 46.800
LEVEL 1
AHD 44.000
A05
CON-01
A04
RF-01
A03 RF-02
A02
A01
REFER TO SERVICES RE SOLAR PANEL LOCATION
CON-01
LV-01
BRK-03
LV-01
REFER 2141.02_TECHNIC FOR EXTERNAL MATERI WINDOWS, CEILINGS, FE
RF-01
AL-01
8800 MAXIMUM BUILDING HEIGHT (BLOCK A02)
A07
COVERED ENTRY
FOLDED ALUMINIUM HOOD DETAIL AROUND CANTEEN WINDOWS COVERED WALKWAY
GROUND
AHD 40.000
BRK-01
BRK-01
AL-05
BRK-01 LV-01
LV-01
EXISTING GROUND LINE
STAIR 1
NORTH ELEVATION SCREENING & BALUSTRADES 1 : 100
A07
A06
AHD 46.800
LEVEL 1
AHD 44.000
A04
RF-02
LV-01
ROOF
A05
A03
A02
RF-01
BRK-03
A01
RF-01
BRK-03
BRK-03
CON-02
BRK-03
COVERED ENTRY
LV-01
FOLDED ALUMINIUM HOOD DETAIL AROUND CANTEEN WINDOWS BRK-01
OUTDOOR LEARNING AREA
GROUND
AHD 40.000
AL-05 BRK-01
BRK-01
8800 MAXIMUM BUILDING HEIGHT (BLOCK A02)
1 A03.01
3 2 1
SSDA ISSUE SSDA ISSUE PRELIMINARY SSDA
Rev
Description
STATE SIGN DEVELOPME
BRK-01
EXISTING GROUND LINE
LV-01
2
Melbourne 4/135 Sturt Street Southba T 0+61 3 9699 3644 www.hayball.com.au
NORTH ELEVATION - WITHOUT SCREENING
A02.A04.01 1 : 100
Sydney Ground Floor, 11-17 Buck T +61 2 9660 9329
A01
A02
LEVEL 1
AHD 44.000
A05
Brisbane Level 12, 324 Queen Stre T +61 7 3211 9821
A07
NSW Nominated Archite Tom Jordan 7521, Richard 8028 ABN 84 006 394 261
RF-02
GT-01
CL-01
Builders/Contractors shall verify job dimens precedence over scaled work. Work shall a dimensions. All shop drawings shall be sub commence prior to the return of inspected 2008 All rights reserved
Client: AL-01
AL-03 BRK-03
COVERED ENTRY
AL-01 BRK-01
FOLDED ALUMINIUM HOOD
GROUND
A06
BRK-03
BRK-03
LOUVRED CANOPY OVER
BRK-01 BRK-01
LV-01
COVERED OUTDOOR LEARNING
8800 MAXIMUM BUILDING HEIGHT (BLOCK A02)
AHD 46.800
A04 RF-01
RL 48.80
AL-01
ROOF
A03
AHD 40.000
Jordan Springs BLOCK A02
14-28 Cullen Avenue, Jord
DRAWINGTITLE
ELEVATIONS
3
SOUTH ELEVATION
A02.A04.01 1 : 100
Excerpt from architectural drawing set / Revit
NK/DS DRAWN BY DT CHECKED DATE PRINTED 05-Nov 1 : 100 SCALE
15
PROJECT NUMBER
D
2141.02 A0
Project: Western Sydney Wollongong Schools/ Tender option Involvement: Assisted in documenting window schedules and amended stair/ramp documentation package to follow EFSG specifications across 6 schools; Cecil Hills PS, Riverstone HS, Gwynneville PS, Canley Vale HS, Quakers Hill PS, Wollongong PS
WIDTH EQ
WIDTH 50
INSTALL ROLLER BLIND RB-01 IN FRONT OF ALL GLAZING INTERNALLY.
50
EQ
50
EQ
50
BREEZWAY ALTAIR STRONGHOLD LOUVRE SYSTEM - 4PANEL SCREEN.
SLIDING WINDOW WITH FIXED GLASS TO EITHER SIDE.
GL01
SC-01 OVER GLASS LOUVRES EXTERNALLY.
GL01
GL01
GL01
INSTALL ROLLER BLIND RB-01 IN FRONT OF ALL GLAZING INTERNALLY.
GL01
WE.01a
FG
ROLLER BLIND RB-01 IN FRONT OF ALL GLAZING INTERNALLY.
FG
FFL
1090 840 1070 1090 1090 1090 1070
0 0 0 0 0 0 0
EQ
GL01
HEIGHT
S
ROLLER BLIND RB-01 IN FRONT OF ALL GLAZING INTERNALLY.
SILL HEIGHT
TRANSLUCENT FILM
WIDTH
2560 2560 2229 2229
PC-01
POWDERCOAT FINISH TO FRAMES - DARK BRONZE - 906 8184L ELECTRO POWDERCOAT RANGE
LV-01
FULL HEIGHT EXTERNALLY FIXED ELIPSOID LOUVRE BLADES TO NORTH FACING WINDOWS
FR1
CAPRAL NARROWLINE 400 SERIES (101.6X44MM) ALUMINIUM FRAMING SYSTEM
FR2
CAPRAL NARROWLINE 425 SERIES DOUBLE GLAZED
GL01
EXTERNAL GLAZING TYPE: VIRIDIAN COMFORTPLUS NEUTRAL 6.38MM SGU
GL05
INTERNAL GLAZING TYPE: DOUBLE GLAZED UNIT
SILL HEIGHT
4650 4480 4570 4530
SHOP DRAWINGS TO BE SUBMITTED FOR FINAL APPROVAL DIMENSIONS SHOWN ARE NOMINAL AND ARE TO STRUCTURAL/WALL OPENINGS. CONFIRM ON SITE PRIOR TO MANUFACTURE/INSTALLATION
600 600 600 600
ANY DISCREPANCIES TO BE NOTIFIED TO THE ARCHITECT, AND WRITTEN APPROVAL OBTAINED PRIOR TO MANUFACTURING. REFEF TO PLANS FOR SLIDING DIRECTION PROVIDE AND FIT RECESSED POWDERCOATED ALUMINIUM COVER PLATES AND SILL INFILLS TO MATCH ADJOINING ALUMINIUM FRAME AS REQUIRED. COVER PLATES TO HAVE CONCEALED FIXINGS. ALL WINDOWS VIEWED FROM EXTERIOR OR OUTSIDE OF ROOM APPLICABLE UNLESS OTHERWISE NOTED. ALL BUTT JOINED GLAZING PANELS TO HAVE CLEAR SILICON SEALS. REFER TO ELECTRICAL ENGINEERS DRAWINGS & SPECIFICATION FOR ELECTRONIC SECURITY. ALL LOCKS AND KEYS TO EXISTING MASTER KEY SYSTEM. GLAZING FILM AND DECALS TO BE AVERY DENNISON FILM, COLOUR: FROSTED GLASS.
THERMAL PERFORMANACE FOR ALL EXTERNAL WINDOWS MUST HAVE FOLLOWING VALUES: - U: 4.16 - SHGC: 0.48 CONTRACTOR TO PROVIDE SHOP DRAWINGS CONFIRMING THESE VALUES ARE ACHIEVED, FOR REVIEW.
WE.06a HIGHLIGHT WINDOWS FIXED GLAZING WINDOW WITH CAPRAL 400 NARROWLINE FRAMING TO SURROUNDS.
WIDTH 50
INSTALL ROLLER BLIND RB-01 IN FRONT OF ALL GLAZING INTERNALLY.
EQ
EQ
EQ
SJ
GL01
FG
50
SILICON JOINT TO ABUTTING GLAZING PANELS.
SJ
GL01
FG
EQ
SJ
GL01
FG
EQ
SJ
GL01
PC-01 FINISH TO FRAME.
GL01
FG
B A
INSTALL ROLLER BLIND RB-01 IN FRONT OF ALL GLAZING INTERNALLY.
FG
Rev
CDC ISSUE STAGED CDC ISSUE
16/08/18 27/07/18
Description
Date
FR2
FR2
FFL
WINDOW NUMBER
900 900 900 900 900
WE.08
EQ
W.B.002.2 W.B.004.2 W.B.005.3 W.B.026.2 W.B.029.1 W.B.036.1 W.B.102.1 W.B.104.1 W.B.113.1 W.B.122.1 W.B.126.1
HEIGHT
1800 1800 1800 1800 1800 1800 1800 1800 1800 1800 1800
Melbourne 4/135 Sturt Street Southbank, VIC 3006 T +61 3 9699 3644
WE.06a WIDTH
SILL HEIGHT
1450 1450 1450 1450 1450 1450 1450 1450 1450 1450 1450
WINDOW NUMBER
429 429 429 429 429 429 429 429 429 429 429
W.B.102.4 W.B.105.3 W.B.113.3 W.B.122.4 W.B.125.3
HEIGHT
1148 1320 890 1150 1140
WIDTH
SILL HEIGHT
6700 7000 8600 6700 7000
50
1527
50
1200
50
50
1200
50
1100
50
50
1475
50
1200
Sydney Ground Floor 11-17 Buckingham Street Surry Hills NSW 2010 T +61 2 9660 9329
Brisbane Level 12, 324 Queen Street, Brisbane Qld 4000 T +61 7 3211 9821
ABN: 84006394261 NSW Nominated Architects:Tom Jordan 7521, Richard Leonard 7522, David Tordoff 8028
3000 3210 3000 3000 3210
Project Title
WI.06
ALUMINIUM WINDOW SPLIT. 50% FIXED GLASS PANEL AND 50% BREEZWAY ALTAIR STRONGHOLD LOUVRE SYSTEM - 1 PANEL SCREEN.
50
50
50
1200
50
1473
FIXED GLAZING WINDOW WITH GLAZED SLIDING DOOR. PC-01 FRAME FINISH.
50
SC-01 OVER GLASS LOUVRES EXTERNALLY (UNLESS LV-01 IS NOMINATED).
50
50
FM01
SILL
4090 2650 4090 4090 4090
EQ
HEIGHT
WE.05 WIDTH
WIDTH 50
OPERABLE
ALL FINAL WINDOW SIZES ARE SUBJECT TO FURTHER STRUCTURAL & DETAIL COORDINATION.
PC-01 FRAME FINISH.
GL01
SILL
SILL
BOTTOM TRACK OF WINDOW RECESSED INTO PRACTICAL ACTIVITIES BENCH
2314 2314 2314 1886 1886
W.B.002.3 W.B.018.1 W.B.102.3 W.B.122.3
FOLDED ALUMINIUM HOOD DETAIL AROUND WINDOW AL-05 WHERE SHOWN ON ELEVATIONS.
WE.03b W.B.003.1 W.B.017.1 W.B.017.3 W.B.103.1 W.B.121.2
1029 857 1029 857 857 1029 857 857 1029 857 1029 857 1029 857 1029 857
FIXED GLAZING IN SHOPFRONT GLAZING POCKET.
FG
HEIGHT
WINDOW NUMBER
WE.05 WIDTH
SILICONE JOINT
O
FG
FR2
WINDOW NUMBER
SILL HEIGHT
3850 3750 3850 3750 3750 3850 3750 3750 3850 3750 3850 3750 3850 3750 3850 3750
EXTERNALY. PC-01 FRAME FINISH.INSTALL
S
FG
FFL
GL01
HEIGHT
GL01
1372 1372 1372 1372 1372 1372 1372 1372 1372 1372 1372 1372 1372 1372 1372 1372
FRAMELESS SLIDING WINDOW WITH FIXED GLASS TO EITHER SIDE. SC-02 FLYSCREEN TO CANTEEN WINDOW
GL01
WE.03a WIDTH
Cecil Hills Public School Project Address
PC-01 FRAME FINISH.
GL05
GL05
GL05
GL05
GL05
GL05
GL05
Leopold Place, Cecil Hills, NSW 2171
GL05
FG
FG
W.B.006.2
WE.08 WINDOW NUMBER
W.B.007.1 W.B.105.2 W.B.109.1 W.B.125.1
HEIGHT
3286 3130 3130 3130
WIDTH
6330 3200 3200 3200
SILL HEIGHT
-86 -330 -330 -330
W.B.027.1
W.B.106.2
BUILDING B06 - HOME BASE WINDOW SCHEDULE 1000
FG
W.B.124.2
900
FM02
1000
FG
900
FM02
100
2800
Drawing Title
S
100
2800
S
100
FM02
1000
100
FM02
900
PC01
S
1000
VISION CONTRAST STRIP WHERE REQUIRED IN ACCORDANCE WITH AS1428.1 & AS1288
FFL
2800
S
900
INSTALL ROLLER BLIND RB-01 IN FRONT OF ALL GLAZING INTERNALLY.
2800
HEIGHT
PROVE 1 POWER LOUVRE + ADAPTIVE CONTROL UNIT PER ROOM, MOTOR CONCEALED INTO WINDOW HEAD.
GL01
GL01
50
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE 16
W.B.001.1 W.B.002.1 W.B.003.2 W.B.004.1 W.B.005.2 W.B.017.2 W.B.026.1 W.B.029.2 W.B.101.1 W.B.102.2 W.B.103.2 W.B.104.2 W.B.121.1 W.B.122.2 W.B.123.3 W.B.126.2
HEIGHT
WE.03b
WIDTH EQ
WINDOW NUMBER
50
3200 3200 3200 3200 3200 3200 3200
SILL HEIGHT
HEIGHT
W.B.001.2 W.B.001.3 W.B.005.1 W.B.006.1 W.B.019.1 W.B.019.2 W.B.020.1
WE.01d WIDTH
ALL GLAZING TO BE IN ACCORDANCE WITH AS1288 AND OTHER RELEVANT AUSTRALIAN STANDARDS.
FIXED GLAZING
SJ
DECALS TO ALL FULL HEIGHT GLAZED PARTIONS AND WINDOWS AT 900MM AFFL. DECALS TO BE 75MM HIGH SOLID STRIP IN ACCORDANCE WITH AS1428.1
FR2
50
HEIGHT
NOTES
FG
SC-02 FLYSCREEN TO CANTEEN WINDOW
S
PC01
WINDOW NUMBER
LEGEND
EXTERNALY. PC-01 FRAME FINISH.INSTALL
FRAME. 3X MANUAL CONTROL & 1X POWERLOUVRE + ADAPTIVE CONTROL FOR 1 PANEL.
PC01
GL01
S
50 50
HEIGHT
POWDERCOAT PC-01 FINISH ON ALUMINIUM GL01
GL01
50
FFL
EQ
50
LV-01 FULL HEIGHT EXTERNALLY FIXED ELIPSOID LOUVRE BLADES TO NORTH FACING WINDOWS MANUAL CONTROL.
50
SILL
POWDERCOAT PC-01 FINISH ON ALUMINIUM FRAME.
GL01
EQ
50
SC-01 OVER GLASS LOUVRES EXTERNALLY.
WE.03a
HEIGHT
BREEZWAY ALTAIR STRONGHOLD LOUVRE SYSTEM - 1 PANEL. SCREEN.
WE.01d
SILL
WE.01a
50
HEIGHT
EQ
50 50
WIDTH 50
FFL
Status
DESIGN DEVELOPMENT NOT FOR CONSTRUCTION Drawn By GD
Checked By
Date Printed
Scale
TZ
25/09/2018 3:01:19 PM
1 : 50@ A1
Revision
Project No
Drawing No
2141.06
B06. A21.51 B
Builders/Contractors shall verify job dimensions before any job commences. Figured dimensions shall take precedence over scaled work. Work shall also conform to the specification, other drawings and job dimensions. All shop drawings shall be submitted to the Architect/Consultant and manufacture shall not commence prior to the return of inspected shop drawings signed by the Architect/Consultant. © Copyright 2008 All rights reserved
Excerpt from architectural drawing set / Revit
B2 SOFT FALL TO TOP LANDING. PROVIDE 15mm SETDOWN IN SLAB TO EXTENT AND INSTALL FLUSH WITH ADJACENT FLOOR
6
B2
LV-01 FIXED VERTICAL LOUVRE SCREEN. MAX SPACING 120mm
6
RAMP UNDER REVIEW
B1
A08.01
1463
1463
1607
SF-01
FX-02 NOSING STRIPS WHERE SHOWN
UP 14 13 12 11 10
9
8
7
6
5
4
3
2
1
50
600 TGSI
300
2200 13 EQ TREADS AT 275mm EACH
3580 13 EQ TREADS AT 275mm EACH
1000
B1
300
1650
MIN BALUSTRADE HEIGHT OVER NOSINGS/LANDINGS 3460
TGSI TO COMPLY WITH AS1428.4
126
23 22 21 20 19 18 17 16 15
FX-01
TYPICAL HANDRAIL HEIGHTS ABOVE NOSINGS/LANDINGS 200
UP
FX-01
600 TGSI
700
1400
CON-01
CLEAR WIDTH
RL 69.46
3
A08.01
1582
1200 MIN
1:1.8
NOM 166mm EACH
1000
126 50
AHD 69.500
SF-01
MIN CLEARANCE
SF-01
1
GROUND FLOOR
2
3
4
5
6
7
9
8
11
12
13
3
B2
14
A08.01
15
16
18
19
20
21
22
23
CENTRE POSTS ON TREADS TYP.
7
A08.01
AHD 66.000
REFER LANDSCAPING DOCUMENTATION
WEST STAIR_SECTION A 1 : 50
FLOOR PLAN - WEST STAIR
1 A03.02
10
17
900
90 MAX
FIRST FLOOR
4
A08.01
700
200
A08.01
1200
B1
B2
1 : 50
B1
6
A08.01
B9
LEVEL 1 BALUSTRADE BEYOND DASHED
B10
PERFORATED ALUMINIUM BALUSTRADE. FINAL DETAIL TBC GATE WITH CHILDPROOF LOCK
4275
EAST STAIR SECTIONS AND DETAILS SIMILAR TO WEST STAIR FIRST FLOOR
FX-02 NOSING STRIPS TO ALL TREADS
AHD 69.500
2
3
4
5
6
7
8
9
10
11 12
13
14
FX-01
UP
CON-01
TYPICAL HANDRAIL HEIGHTS ABOVE NOSINGS/LANDINGS
RL 69.46 15 16
17
18 19
20
21 22 23
600
320
3575
TGSI
2 A03.02
1000
2200
13 EQ TREADS AT 275mm EACH
FLOOR PLAN - EAST STAIR 1 : 50
300
8 EQ TREADS AT 275mm EACH
700
51
1
RL 68.09
200
CON-01
UP
RL 66.00
1752
FX-01
126
TGSI TO COMPLY WITH AS1428.4
1400
126
49
1200mm HIGH BALUSTRADE ABOVE STAIR NOSINGS/LANDINGS HANDRAIL BEYOND DASHED
600
1
GROUND FLOOR
TGSI
2
3
4
5
6
7
9
8
10
11
12
13
14
15
16
17
18
19
20
21
22
23
STEPS BEYOND DASHED
B A
Rev
RAMP UNDER REVIEW
CDC ISSUE STAGED CDC ISSUE
16/08/18 27/07/18
Description
Date
8
A08.01
AHD 66.000
B9
4
B10
A08.01
WEST STAIR/RAMP_SECTION B 1 : 50
15mm SOFT FALL 15mm SOFT FALL SURFACE OVER 65mm SURFACE APPLIED OVER UNDERLAY AS CONCRETE RAMP SCHEDULED
RAMP UNDER REVIEW
Melbourne 4/135 Sturt Street Southbank, VIC 3006 T +61 3 9699 3644
Sydney Ground Floor 11-17 Buckingham Street Surry Hills NSW 2010 T +61 2 9660 9329
Brisbane Level 12, 324 Queen Street, Brisbane Qld 4000 T +61 7 3211 9821
ABN: 84006394261 NSW Nominated Architects:Tom Jordan 7521, Richard Leonard 7522, David Tordoff 8028
38
B2
BOLT FIXED CLIMBING HOLDS AS SCHEDULED. INSTALL TO MANUFACTURER'S DETAILS
FX-02 NOSING STRIPS TO FULL WIDTH OF CONCRETE TREADS
10mmD STAINLESS STEEL ROD STANDOFF BRACKETS
300 75
EQ 1200 20
EQ
900 RL 66.50 20
FIRST FLOOR
12
Cecil Hills Public School
RAMP UNDER REVIEW
700
LEVEL 1 SLAB
75x25mm VERTICAL METAL BALUSTERS WITH MAX 120mm OPENINGS BETWEEN
SF-01
LV-01 VERTICAL LOUVRES WITH MAX 120mm OPENINGS BETWEEN
15
CON-01
300
6 A08.01
WEST STAIR/RAMP_LATERAL SECTION 1 : 10
RAMP WITH SOFT FALL SURFACE AND BOLT FIXED CLIMBING HOLDS. REFER SCHEDULE
A08.01
TYPICAL TREAD DETAIL SECTION 1 : 10
15
50
CAST IN FLUSH FX02 STAIR NOSING AS SPECIFIED. REFER PLAN FOR LOCATIONS
CONCRETE STRUCTURE
200
200x130mm EA SHELF ANGLE (CUT BACK FROM 200mmEA) RAKED UP SIDE OF STAIR. TERMINATE AT L1 SLAB SOFFIT
7
RADIUS EDGE
VARIES
CONCEALED SPIGOT BASE FIXING TO ALL HANDRAIL POSTS. CHEMSET FIXINGS INTO CONCRETE
Project Address
PAVING SLAB
900
AHD 69.500
Project Title
RAKE RISERS BACK 20mm OFFSET FROM NOSING AT BASE. EFFECTIVE TREAD DEPTH 270mm
50 38
200
1200mm HIGH BALUSTRADE ABOVE STAIR NOSINGS/LANDINGS
15
AFFL -3000
50 38
38mmOD STAINLESS STEEL TUBE HANDRAILS AND POSTS AS SCHEDULED
15 50
REINFORCED CONCRETE STAIRCASE TO STRUCTURAL ENGINEER'S DETAILS
38 50 38 900
1348
862
50 38 50 38
NOM 166
75x25mm VERTICAL METAL BALUSTERS WITH MAX 120mm SPACING
15mm SQUARE REBATE ALONG BOTH EDGES OF SLAB SOFFIT
5
TYPICAL CONCRETE STAIR NOSING DETAIL 1:2
8 A08.01
RAMP DETAIL SECTION 1 : 10
RAMP AND STAIR SOFFIT TO BE FLUSH. STRUCTURAL ENGINEER TO CONFIRM MINIMUM REQUIRED THICKNESSES
Leopold Place, Cecil Hills, NSW 2171 Drawing Title
STAIR DETAILS Status
DESIGN DEVELOPMENT NOT FOR CONSTRUCTION Drawn By
Checked By
Date Printed
Scale
Author
TZ
25/09/2018 3:00:23 PM
As indicated@ A1
Project No
Drawing No
2141.06
B06. A08.01 B
Revision
Builders/Contractors shall verify job dimensions before any job commences. Figured dimensions shall take precedence over scaled work. Work shall also conform to the specification, other drawings and job dimensions. All shop drawings shall be submitted to the Architect/Consultant and manufacture shall not commence prior to the return of inspected shop drawings signed by the Architect/Consultant. © Copyright 2008 All rights reserved
Excerpt from architectural drawing set / Revit 17
Project: St John’s Primary School, Frankston East/ Schematic Design, Design Development, Tender Option Involvement: Assisted in preparing schematic design package presentation, prepared renderings for tender option package, involved in design
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
development documentation up to tender package.
18
Photo manipulation rendering of external balcony and staircase for tender option package / Revit, Enscape, Photoshop
01
Architectural Design Artist’s Impressions - Interiors
FLOOR PLAN - LEVEL 1 St John’s Primary School Jayne Street, Frankston East
Design Development Report 00 August 2018
Project No 2150
Hayball
3
Excerpt from schematic design presentation set / Revit, Photoshop, InDesign 19
Project: St John’s Primary School, Frankston East/ Schematic Design, Design Development, Tender Option Involvement: Assisted in preparing schematic design package presentation, prepared renderings for tender option package, involved in design development documentation up to tender package. 1580 90
1400 CLEAR HANDRAIL TO HANDRAIL
90
33mm DIA. STAINLESS STEEL DUAL HEIGHT HANDRAIL
33mm DIA. STAINLESS STEEL DUAL HEIGHT HANDRAIL SN01
5
A16.01
40x40 STEEL STANCHION WITH 10mm DIA. STAINLESS STEEL RODS
SN01
40x40 STEEL STANCHION WITH 10mm DIA. STAINLESS STEEL RODS
SN01
FC01
2400 DATUM
AHD 37.200 D1.06 1580 STAIR
EXISTING WALL
1400 CLEAR HR TO HR
LEVEL 1 UPPER AHD 35.580 1050
STEEL STAIRS AND LANDINGS AS SPECIFIED
FC01
10
50
300PFC STRINGER - REFER TO STRUCT. ENG'S DWGS
300PFC STRINGER - REFER TO STRUCT. ENG'S DWGS
28
26
35 0
350
27
FC01
NEW COLUMN - REFER TO STRUCT. ENG'S DWGS
25 24 23 22
350
10
50
21 20
STEEL COLUMN - REFER TO STRUCT. ENG'S DWGS
19 18
1 : 10
STEEL COLUMN - REFER TO STRUCT. ENG'S DWGS
17
FC01
2993 17 RISERS @ 176mm
EXTERNAL STAIR SECTION 2
35 0
6
A16.01
880 5 RISERS @ 176mm
SN01
16 15 14 13 12
FC01
11 10
GROUND D1.06
2460
7 6 5
4
4
3
3
2
2
1
1
STEEL COLUMN REFER TO STRUCT. ENG'S DWGS
4192
3
26
1400 CLEAR HR TO HR 1580
22 21
20
20
19
19
18
18
17
17
28 27 26
16
25 15
24 23
14
21
12
11
11
10
10
9
9
20 19 18
17 16
STEEL STAIRS AND LANDINGS AS SPECIFIED
8 7
250
7
33mm DIA. STAINLESS STEEL DUAL HEIGHT HANDRAIL
22
13
8
SN01
A16.01
900
12
6
D1.06
LEVEL 1 UPPER AHD 35.580
665
4000
13
AHD 37.200
900
23
21
14
AHD 37.980
2400 DATUM
24
22
15
CEILING
25
FC01
23
16
1 : 50
665
300 1000 1610
NEW FENCING TO EXISTING SERVICES
EXTERNAL STAIRCASE ELEVATION 2
27
16 TREADS @ 250mm
FEN01
4
TC01
4 TREADS @ 250mm
4 NEW COLUMN REFER TO STRUCT. ENG'S DWGS
1 : 50
28
LANDING
4
EXISTING NATURAL GAS METER AND VALVE
EXTERNAL STAIRCASE ELEVATION 1
3
600
3
15 14 13
90
12 11
4
5
6
1
UP
3
4
5
9
6
GROUND
UP
8
AHD 30.960
7
6
5 600
250
1250 5 TREADS @ 250mm
1400
90
4
4
A16.01
1
2
900
3
665
TC01
2
1580
1580 STAIR
5
1400 CLEAR HR TO HR
10 1
A16.01
GF EXTERNAL STAIR PLAN 1 : 50
5
A16.01
20
8
5
FEN01
NEW FENCING TO EXISTING SERVICES
FC01
9
AHD 30.960 6
90
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
FC01 NEW COLUMN REFER TO STRUCT. ENG'S DWGS
1056 6 RISERS @ 176mm
STEEL STAIR AS SPECFIED
PROJECT NAME
St John's Primary School
2
A
5
L1 EXTERNAL STAIR PLAN 1 : 50
5
A16.01
DRAWING TITLE
EXTERNAL STAIR DETAILS
EXTERNAL STAIR SECTION 1 1 : 50
A
DRAWN BY
Author
CHECKED
Checker
PROJECT NO
2150
DWG NO
A16.01
REV
B
Hayball Pty Ltd 4/ 135 Sturt Street Southbank Victoria Australia 3006
NSW Nominated Architects: Tom Jordan 7521, Richard Leonard 7522,
MAINTAIN EXISTING RESTRICTORS TO ALL OPENABLE WINDOWS BELOW 1000MM FFL
L
ROOF
AHD 38.700
CEILING
AHD 37.980
2400 DATUM
AHD 37.200
K
J
I
H
G
F
E
D
C
B
A
LOUVRED GLASS WINDOWS
LEVEL 1 UPPER AHD 35.580
FC01
GROUND
NEW FIRE ESCAPE STAIRCASE TO AS1428
AHD 30.960
NEW FENCING TO EXISTING SERVICES EXISTING EXTERNAL STAFF DECK AREA
1
PROPOSED - NORTH ELEVATION 1 : 100
MAINTAIN EXISTING RESTRICTORS TO ALL OPENABLE WINDOWS BELOW 1000MM FFL
A
ROOF
AHD 38.700
CEILING
AHD 37.980
2400 DATUM
AHD 37.200
B
C
D
E
F
G
H
I
J
K
L
FC01
LEVEL 1 UPPER AHD 35.580 FC01 NEW FIRE ESCAPE STAIRCASE TO AS1428
GROUND
AHD 30.960
FEN01
EXISTING BUILDING ENTRY
FC01
EXISTING NATURAL GAS METER AND VALVE EXISTING SERVICES UNITS
2
EXISTING BUILDING ENTRY
PROPOSED MECHANICAL & HYDRAULIC PLANT LOCATION
PROPOSED - SOUTH ELEVATION 1 : 100
1
ROOF
AHD 38.700
CEILING
AHD 37.980
2400 DATUM
AHD 37.200
2
3
4
5
EXISTING MULTI-PURPOSE HALL - OUT OF SCOPE
D1.06
NEW FIRE ESCAPE STAIRCASE TO AS1428
NEW ENTRY DOOR
LEVEL 1 UPPER AHD 35.580
FC01 FC01
EXISTING BUILDING ENTRY
EXISTING OUTDOOR STAFF DECK AREA
GROUND
AHD 30.960 D.08
FEN01 AHD 29.880
AHD 29.700
AHD 29.700
3
NEW FENCING AND GATE TO EXISTING SERVICES
PROPOSED - WEST ELEVATION
EXISTING NATURAL GAS METER AND VALVE
1 : 100
PROJECT NAME
St John's Primary School PROJECT ADDRESS
Jayne Street, Frankston East
DRAWING TITLE
EXTERNAL ELEVATIONS - PROPOSED
DRAWN BY
DS
CHECKED SCALE
Checker
DATE PRINTED
04.09.2018
0
1
PROJECT NO
1 : 100@ A1
2
3
5 m
2150 STATUS
PRELIMINARY
DWG NO
A05.01
REV
D
D C B A REV
04.09.2018 27.08.2018 10.08.2018 30.07.2018 DATE
UPDATES TO CONSULTANTS ISSUED TO CONSULTANTS DD ISSUE TO CLIENT PRELIMINARY ISSUE TO QS FOR COSTING DESCRIPTION
Hayball Pty Ltd 4/ 135 Sturt Street Southbank Victoria Australia 3006 T 03 9699 3644 F 03 9699 3708 www.hayball.com.au
NSW Nominated Architects: Tom Jordan 7521, Richard Leonard 7522, Robert Stent 7523, Geoffrey Hammer 5147 ABN 84 006 394 261
Builders/Contractors shall verify job dimensions before any job commences. Figured dimensions shall take precedence over scaled work. Work shall also conform to the specification, other drawings and job dimensions. All shop drawings shall be submitted to the Architect/Consultant and manufacture shall not commence prior to the return of inspected shop drawings signed by the Architect/Consultant. © Copyright 2008 All rights reserved
21
Project: St John’s Primary School, Frankston East/ Schematic Design, Design Development, Tender Option Involvement: Assisted in preparing schematic design package presentation, prepared renderings for tender option package, involved in design development documentation up to tender package. C
D
E
E
450
5029 450
450
PLY01 J01a
450
3829
450
TM01
PLY01
A11.02
TM01
TM01
TM01
TM01
TM01
TM01
TM01
TM01
TM01
TM01
TM01
3.95°
550
PLY01
550
PLY01
C 1
A17.01
450
PLY01
PLY01
3
D
4
NOTE: J01b OVERALL WIDTH TO FIT IN BETWEEN TIMBER SLAT PARTITION
5929 C.O.S.
PLY01
3.95°
TM01
VOID
VOID
VOID
VOID
PLY01
PLY01
PLY01
PLY01
VOID
VOID
PLY01
PLY01
VOID
VOID
VOID
VOID
VOID
VOID
VOID
PLY01
PLY01
PLY01
PLY01
VOID
PLY01 TM01 A17.01
6
5
A17.02
450
3220
600
4
PLY01
PLY01
A17.01
J01b
PLY01
TM01
PLY01
PLY01
PLY01
CP03
CP03
900
3829
900
CP03 TM01 450
PLY01
PLY01
CP03
CP03
250
600
TM01 CP03
PLY01
CP03
CP03
250
PLY01
500
3
3830
A17.01
2670
3370
600
C.O.S.
TM01 450
450
CP03
5029
450
?
5929
CP03
22
460
5
A11.01
J01a - DETAIL ELEVATION
PLY01
1 : 20
PLY01 TIMBER FRAMING TO SUIT
PLY01
12
A17.01
LAM01
LAM01
LAM01
1 : 20
425
A00.05
PLY01
J01a & J01b - DETAIL PLAN
PLY01
6700
18
2
1
NOM. 12mm SHADOWLINE DETAIL. EXPOSED FACE TO BE PAINTED WITH COLOUR TO MATCH OPEN SHELVING CARCASS
6550
0
150
150
150
FS
4
A17.01
0
LAM01
FIXED PANEL OF PRE FINISHED MDF WITH SELECTED LAMINATE. POSITION VARIES. REFER DETAIL ELEVATION FOR VARIATION OF FIXED PANEL'S POSITION.
425
LAM01
18
LAM01
LAM03 OPEN SHELVING
FP
LAM03
LAM03 OPEN SHELVING FP
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING FP
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING FP
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING FP
FP
EQ
FP LAM03 LAM03 OPEN SHELVING
LAM03 LAM03 OPEN SHELVING
LAM03 OPEN SHELVING FP
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
EQ
EQ
EQ
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03
FP
FP
EQ
FP LAM03
EQ
EQ
EQ
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
150
PLY01
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
EQ
EQ
EQ
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
EQ
FS
LAM03 LAM03 OPEN SHELVING
EQ
75
EQ
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
FP
LAM03
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03
FP
FP LAM03 LAM03 OPEN SHELVING
LAM03
FP
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING FP
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03
FP
FP
LAM01
FP LAM03
LAM01
LAM03 OPEN SHELVING
PLY01
LAM03 LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
425
LAM03
FP
EQ
LAM03 OPEN SHELVING
425
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
EQ
LAM03 OPEN SHELVING
LAM01
9
A17.00
PLY01 LAM01
LAM03
LAM01
18
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
EQ
FP LAM03
50
LAM03
LAM03
EQ
LAM03 OPEN SHELVING
460
50
1550
150 425
FP
FP
EQ
LAM03 OPEN SHELVING
425
LAM03 OPEN SHELVING
LAM03 OPEN SHELVING
EQ
LAM03 OPEN SHELVING
1550
LAM03 OPEN SHELVING
EQ
FP LAM03
1550
LAM03 OPEN SHELVING
150
EQ
LAM03 OPEN SHELVING
PLY01
3370
425
EQ
425
150 75
EQ
LAM03 OPEN SHELVING
425
6700
50
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
4
50
2
A17.01
J01b - DETAIL ELEVATION 1
3
A17.01
PROJECT NAME
St John's Primary School PROJECT ADDRESS
SELECTED FLOORING FINISH
?
1 : 20
J01 - DETAIL ELEVATION 2
4
1 : 20
A11.02
J01a - DETAIL SECTION 1:5
Tender documentation for interiors and joinery package / Revit DRAWING TITLE
JOINERY DETAILS - J01
DRAWN BY
DS
CHECKED SCALE
As indicated@ A1
DATE PRINTED
04.09.2018
0
1
2
3
PROJECT NO
5
2150
DWG NO
A17.01
Hayball Pty Ltd 4/ 135 Sturt Street Southbank Victoria Australia 3006 T 03 9699 3644 F 03 9699 3708 www.hayball.com.au
REV
A
STATUS
PRELIMINARY
A
04.09.2018
UPDATES TO CONSULTANTS
NSW Nominated Architects: Tom Jordan 7521, Richard Leonard 7522, Robert Stent 7523, Geoffrey Hammer 5147 ABN 84 006 394 261
Builders/Contractors shall verify job dimensions before any job commences. Figured dimensions shall take precedence over scaled work. Work shall also conform to the specification, other drawings and job dimensions. All shop drawings shall be submitted to the Architect/Consultant and manufacture shall not commence prior to the return of
WIDTH OF EXPOSED SELECTED TIMBER NOSING
TIMBER NOSING AS SPECIFIED TO MATCH 'PLY01'. MITRE CORNER JUNCTIONS. PROVIDE SAMPLE FOR APPROVAL.
CP03
19
BUTT JOINT SELECTED BROADLOOM CARPET RISER/GOING WITH SELECTED NOSING. MITRE JOINT ALL CORNER JUNCTIONS OF THE SELECTED CARPET FINISH.
350
CONTRACTOR TO ALLOW FOR SUITABLE STRUCTURAL FRAMEWORK AND BRACING AS REQUIRED.
24
LAM02
FS
24
LAM01
880
TYP. TIERED SEATING NOSING DETAIL
LAM01
6
1200
LAM01
A17.00
ADJ 24
LAM02
10
SELECTED BROADLOOM CARPET FIXED ONTO 18MM HMR EO MDF BOARD.
EQ
LAM02
1:2
A17.02
ADJ 24
LAM02
600
24
HD1
EQ
1200
LAM02
500 HIGH
NOM. 3600 C.O.S.
3
A17.02
CP03
WALL CAVITY WIDTH
250
PLY01
10
LAM01
2400
FS
LAM02 CP03
EQ
LAM02
TM01
VARIES. REFER INTERNAL ELEVATIONS FOR CPD HEIGHT C.O.S.
PLY01
CP03
REFER DETAIL PLAN AND ELEVATION FOR DIRECTION OF CARPET RUN.
A17.02
LAM01 LAM01
ADJ
LAM02
10
PLASTERBOARD BULKHEAD WITH FRAMING TO SUIT
EQ
LAM02
CP03
A17.02
2
A17.00
LAM02
SELECTED BROADLOOM CARPET FIXED ONTO 18MM MDF BOARD.
CLM01
12mm SHADOWLINE DETAIL FROM TOP OF HD01 TOP FACE TO CLM01 BENCHTOP BOTTOM FACE
CP03
LAM02 50
EQ
10
820
LAM01
ADJ
LAM02
24
1200
LAM02
A17.00
LAM01 LAM01 LAM01
18 VARIES. REFER DETAIL PLAN FOR DEPTH DIMENSION
450
LAM01
EQ
50
200
STRUCTURAL FRAMING AND BRACING AS REQUIRED
LAM02
LAM01 350
LAM02
700
4
24
LAM02
1:5
LAM01
100
J01 - TIERED SEATING SECTION
100
6 A17.01
690
1
600
A00.05
J03 - DETAIL PLAN
5 A11.01
1 : 20
A17.00
600 700
TYP. TALL CUPBOARD DETAIL SECTION - J02, J05, J08
3
1 : 10
A11.03
J03 - DETAIL SECTION KITCHEN BENCH 1 1 : 10
3
A17.02
3000 C.O.S WALL CAVITY WIDTH EQ
1200
EQ
1200
18
EQ
EQ
ADJ
ADJ
ADJ
ADJ
ADJ
LAM01
LAM01
ADJ
LAM01
LAM01
ADJ
WL01
18
8 A17.02
700
5
MIX01 SNK01
ADJ
LAM01
LAM01
LAM01
LAM01
ADJ
ADJ
LAM01
LAM01
ADJ
7 A00.05
J02 - DETAIL PLAN 1 : 20
PROJECT NAME
St John's Primary School PROJECT ADDRESS
Jayne Street, Frankston East
8 A11.02
J08 - DETAIL PLAN
9
1 : 20
1 : 20
JOINERY DETAILS - J02 AND J03
DRAWN BY
DS
CHECKED SCALE
Checker
DATE PRINTED
04.09.2018
0
LAM01
AHD 34.800
J02 - DETAIL ELEVATION
DRAWING TITLE
18
LEVEL 1
100
LAM01
100
368
EQ
820
A17.02
ADJ
ADJ
LAM01 CLM01
HD1 HD1
25 18
ADJ
600
FS
HD1 HD1
373
ADJ
18
FS
HD1 HD1
2300
FS
ADJ
2400
PB01 2400
EQ
3000 C.O.S.
WALL CAVITY WIDTH
413
ADJ
LAM01
413
LAM01
LAM01
18
LAM01
LAM01
880
LAM01
1
PROJECT NO
As indicated@ A1
2
3
5 m
2150
2 A11.02
J03 - DETAIL ELEVATION
4
1 : 20
DWG NO
A17.02
Hayball Pty Ltd 4/ 135 Sturt Street Southbank Victoria Australia 3006 T 03 9699 3644 F 03 9699 3708 www.hayball.com.au
REV
A
STATUS
PRELIMINARY
J08 & J03 - DETAIL PERSPECTIVE
A REV
04.09.2018 DATE
UPDATES TO CONSULTANTS DESCRIPTION
NSW Nominated Architects: Tom Jordan 7521, Richard Leonard 7522, Robert Stent 7523, Geoffrey Hammer 5147 ABN 84 006 394 261
Builders/Contractors shall verify job dimensions before any job commences. Figured dimensions shall take precedence over scaled work. Work shall also conform to the specification, other drawings and job dimensions. All shop drawings shall be submitted to the Architect/Consultant and manufacture shall not commence prior to the return of inspected shop drawings signed by the Architect/Consultant. © Copyright 2008 All rights reserved
Tender documentation for interiors and joinery package / Revit 23
Project: 2-4 Bruce Street, Box Hill / Town Planning Involvement: Liaised with developer representative in making apartment layout changes 1
3
2
97°20' 15.24 STAGE 01
2995
STAGE 02
10500
1600
42755
4620
BENCH SEAT
1600 1250
BENCH SEAT BENCH SEAT
1250
BENCH SEAT BENCH SEAT
OPEN FIRE STAIR WITH SEAT TO ENCOURAGE USE AND PASSIVE SURVEILLANCE
BENCH SEAT
M0910 57.2 m²
1600
3000
7°41' 20.12
RL. 120.40 COMMUNAL TERRACE 196.1 m²
3000
3600
M1004 78.4 m²
1100
1600
3400
PLANT 14.3 m²
3400
M1005 75.7 m²
Accessible Cross Vent
3000
32 2° 30 '
3600
8.4 m²
9110 SETBACK
12005 6985
SETBACK
CORRIDOR 1500 WIDE
ISSUE FOR CLIENT RFI 1 - FINAL DRAFT TOWN PLANNING ISSUE WIP FRP PPHA RECORDS FOR CONSULTANT TP REPORTS TO CERT FOR BCA REVIEW WIP TO CLIENT AND ESD LANDSCAPE UPDATE APPARTEMENTS ADDED MAB REVIEW TO WIND CONSULT ISSUE FOR CONCEPT AND REPORTS WIP CONCEPT PLANS FOR COUNCIL WIP CONCEPT PLANS FOR COUNCIL 3 WIP CONCEPT PLANS FOR COUNCIL 2 WIP CONCEPT PLANS FOR COUNCIL WIP CONSULTANT COORDINATION WIP CONSULTANT COORDINATION WIP L1 - L19 FOR CLIENT REVIEW WIP FOR CLIENT REVIEW TO MAB FOR COST Q WORK IN PROGRESS SET WORK IN PROGRESS FOR INFORMATION ONLY
28.05.18 10.05.18 22.01.18 15.12.17 22.11.17 21.11.17 16.11.17 15.11.17 14.11.17 10.11.17 20.10.17 10.10.17 27.09.17 26.09.17 22.09.17 07.09.17 01.09.17 16.08.17 02.08.17 03.07.17 29.06.17 23.06.17
Rev
Description
Date
ROOF NO ACCESS MAINTENANCE ONLY
3.0 4
277°20' 13.12
WASTE CHUTE MOVED WEST
SETBACK
3000
SETBACK
INTERNAL AMENDMENTS TO 2B2B THROUGH APARTMENT TO INCREASE LIVING AREA
Accessible Cross Vent
4660
3400
8.0 m²
M1007 68.4 m²
M0907 41.4 m²
Not Accessible Cross Vent
33.3 m²
3600
1200 850
3000
M1006 74.3 m²
Not Accessible Cross Vent
3400
1200
3600
STAIR PRESS
D C B 18 A 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
TOWN PLANNING
INTERNAL AMENDMENTS TO 1B1B APARTMENT
Hayball Pty Ltd 4/135 Sturt Street Southbank Victoria Australia 3006 T 03 9699 3644 F 03 9699 3708 www.hayball.com.au
NSW Nominated Architects: Tom Jordan 7521, Richard Leonard 7522, Robert Stent 7523, Geoffrey Hanmer 5147 ABN 84 006 394 261
Builders/Contractors shall verify job dimensions before any job commences. Figured dimensions shall take precedence over scaled work. Work shall also conform to the specification, other drawings and job dimensions. All shop drawings shall be submitted to the Architect/Consultant and manufacture shall not commence prior to the return of inspected shop drawings signed by the Architect/Consultant. © Copyright 2008 All rights reserved
187°41' 20.12
3000
1200 ELEC
3000 3600
7°41' 20.12
VOID
3000
1550
2700
1550
BALCONY LEVEL BELOW
TOOL SHED 13.1 m²
RL. 120.40
COM
4
DRYING COURTYARD 21.1 m²
GAS HYD
850
1235
AIR RELIEF
M0908 40.7 m²
Not Accessible Not Cross Vent
1813
3600
VOID
8.4 m²
1200
28300
1200
BALCONY LEVEL BELOW
4670 SETBACK 14640
1200
Not Accessible Not Cross Vent
LOUNGE 35.4 m²
3000
3600
3400
3400
LAUNDRY 11.7 m²
Accessible Cross Vent
Not Accessible Not Cross Vent
3600
RL. 120.40
850
1380
3300
M1003 75.5 m²
M1002 69.5 m²
Not Accessible Not Cross Vent
890
1000
M0909 51.4 m²
1200 1380
1200
8.3 m²
3400
8.0 m²
3300
3300
M1001 53.8 m²
Accessible Not Cross Vent
VOID
3145
8.0 m²
3400
3220 SETBACK
187°36'
BENCH SEAT
3000 8.0 m²
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
RAISED ACCESSIBLE PLANTERS
INTERNAL AMENDMENTS TO APARTMENT TO ADD STUDY AREA TO APARTMENT TYPICAL OF M0202
BALCONY LEVEL BELOW
COMMUNAL TERRACE 196.1 m²
Not Accessible Cross Vent
39.62
3600
VOID
3000
24
SEAT
10870 SETBACK
BALCONY LEVEL BELOW
5
17590
20695
SETBACK
4975
97°22'45" 42.67
BRUCE STREET MAB 2-4 BRUCE STREE BOX HILL DRAWINGTITLE
LEVEL 10 277°55' 24.08
276°40' 18.59 NO.913 WHITEHORSE ROAD AUSTRALIAN TAXATION OFFICE AT 20LEVELS
18035
STAGE 02
11040
STAGE 01
DRAWN BY CHECKED DATE PRINTED SCALE
Author Checker 31-May-18 2:53:22 PM 1 : 100
PROJECT NUMBER
DWG NO
2117
TP 01.15
N REVISION
D
22975
Excerpt from town planning documentation package / Revit
Project: Braemar College Woodend / Design Development Involvement: Assisted in preparing facade options for elevations and perspectve views.
L
K
(BEHIND) RF01
CL08
J
RF01
I RF01
?
H
RF01
G
(BEHIND) CL08
RF01
F RF02
RF01
E
(BEHIND) RF01
CL08
D
RF01
C RF01
CL08
B CL02
RF01
A
(BEHIND) RF01
CL08
RF01
RF02
RF02
W.40
YR 5/6 GF
W.11
W.15
AHD577.400
CL02
SUN SHADE TYPE 1 (SUN01)
1
EN OP
W.43
3020
6440
RF02
6440
RF02
CL04
CL04
SUN SHADE TYPE 2 (SUN02)
CL02
CL04
SUN SHADE TYPE 1 (SUN01)
SUN SHADE TYPE 1 (SUN01)
CL04
CL04
CL02
CL04
CL04
SUN SHADE TYPE 2 (SUN02)
CL04
SUN SHADE TYPE 1 (SUN01)
MIDDLE SCHOOL - NORTH ELEVATION
A02.01
1 : 200
PERSPECTIVE PANEL 1 view 2
1
L
K
(BEHIND) RF01
CL08
J
RF01
I RF01
?
H
RF01
CL08
RF01
F RF02
RF01
E
(BEHIND) RF01
CL08
D
RF01
C RF01
CL08
RF01
CL02
RF01
CL08
RF01
6440 W.11
W.15
1
SUN SHADE TYPE 1 (SUN01)
2
EN OP
W.43
AHD577.400
CL02
CL04
CL04
SUN SHADE TYPE 2 (SUN02)
CL02
CL04
SUN SHADE TYPE 1 (SUN01)
SUN SHADE TYPE 1 (SUN01)
CL04
CL04
3020
W.40
YR 5/6 GF
2
A
(BEHIND)
RF02
RF02
RF02
B
6440
RF02
G
(BEHIND)
CL02
CL04
PERSPECTIVE PANEL 1 view 2 CL04
SUN SHADE TYPE 2 (SUN02)
2
CL04
PERSPECTIVE PANEL 2 view 2
SUN SHADE TYPE 1 (SUN01)
MIDDLE SCHOOL - NORTH ELEVATION
A02.01
1 : 200
Revision Number
Description
Date
PRELIMINARY ISSUE 1
L
K
(BEHIND) RF01
CL08
J
RF01
I RF01
?
H
RF01
G
(BEHIND) CL08
RF01
F RF02
RF01
2
E
(BEHIND) RF01
CL08
D
RF01
C RF01
CL08
B
RF01
CL02
A
(BEHIND) RF01
CL08
RF01
3
6440 EN OP
W.43
W.11
W.15
AHD577.400
NSW Nominated Architects: Tom Jordan 7521, Richard Leonard 7522, Robert Stent 7523, Geoffrey Hammer 5147 ABN 84 006 394 261
Builders/Contractors shall verify job dimensions before any job commences. Figured dimensions shall take precedence over scaled work. Work shall also conform to the specification, other drawings and job dimensions. All shop drawings shall be submitted to the Architect/Consultant and manufacture shall not commence prior to the return of inspected shop drawings signed by the Architect/Consultant. © Copyright 2008 All rights reserved
SUN SHADE TYPE 1 (SUN01)
A02.01
Hayball Pty Ltd 4/135 Sturt Street Southbank Victoria Australia 3006 T 03 9699 3644 F 03 9699 3708 www.hayball.com.au
3020
W.40
YR 5/6 GF
PERSPECTIVE PANEL 2 view 2
RF02
RF02
RF02
6440
RF02
PERSPECTIVE PANEL 1 view 2
CL02
CL04
SUN SHADE TYPE 2 (SUN02)
CL04
CL02
CL04
SUN SHADE TYPE 1 (SUN01)
SUN SHADE TYPE 1 (SUN01)
CL04
CL04
CL02
CL04
SUN SHADE TYPE 2 (SUN02)
CL04
CL04
SUN SHADE TYPE 1 (SUN01)
BRAEMAR COLLEGE3 WOODEND PERSPECTIVE PANEL 3 view 2 241 ROMSEY ROAD, WOODEND
MIDDLE SCHOOL - NORTH ELEVATION 1 : 200
DRAWINGTITLE
NORTH ELEVATION PANEL OPTIONS
3
PERSPECTIVE PANEL 3 view 2
DRAWN BY CHECKED DATE PRINTED SCALE
DS Checker
18-May-18 12:37:34 PM 1 : 200
PROJECT NUMBER
DWG NO
1785.1
A06.01A
N REVISION
25
Project: Minaret College, Springvale / Design Development Involvement: Contributed design input towards planning layout of an Islamic
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
ablution block of the school in design development package.
26
Sketches of design options / Hand-drawn
EX TOILETS (WING E) RL 52.40
M
F
NEW LOW LEVEL PLANTING
EXTENT OF NEW CONCRETE PAVEMENT TO CONNECT TO EXISTING
4
NEW CONCRETE PAVEMENT A06.01
NEW RETAINING WALL. REFER TO LANDSCAPE & CIVIL ENGINEER'S DRAWINGS (TYPICAL)
1
A06.11
LOCATION OF EX. SEWERAGE PIT
NEW 1800MM HIGH ACOUSTIC TIMBER PAILING FENCE. EXTENT TBC. REFER TO SHEET A1.04 & A09.02 FOR DETAILS
DRAINAGE AND SEWER EASEMENT E-4
5
NEW 4 GRASSED A08.01AREA
225
3
NORTHERN FORECOURT
A08.01
664
A06.11
RL 52.40
15
2
SEAT
SCREEN O/H (TO FACE OF SCREEN)
C6
C4
1800
C4
J12
J11
P2 C4
C3
TL01
A.29 8 m²
1250
FW02
A.31
TL01 C4
C4
B
C4
WALKWAY 1:50 SEAT
SEAT
A07.01
BUILDING LINE O/H (TO FACE OF GLAZING SYSTEM)
7500
TILED UNDERCROFT AREA
NEW PLANTER. REFER TO LANDSCAPE ARCHITECT'S DRAWINGS FOR DETAILS
1
WALKWAY 1:75
WALKWAY 1:50 WG.04
C1
WG.03
C1
WG.05
SC01
CO L
UTILITIES
STORE MECH
NEW UNFENCED LANDSCAPED AREA
17400 CLEAR
CO L
CO L
P6
3 m²
13 m²
RS01
CO L
A.16 7 m²
DG.16.1
6 m²
A.09
P3A
3 m²
ELEC S/B
P3A
J07
A.11
DG.12.1
P4
42 m²
P2
STAFF BREAK-OUT
P5
31 m²
WG.09
C1
C1
?
7800
1
REFER TO LANDSCAPE ARCHITECT'S DRAWINGS FOR DETAILS
AHD 52.50
1
A06.11
7800
7200
2
3
4800
4
1200
5a
3
CO L
A.17
A06.01
Description
02.07.2018 22.06.2018 20.06.2018 06.06.2018
Date
F
5 m²
DG.17.1
H.O.S.
J08
A.13
C.OFF.
7
WG.06
A06.12
C.OFF.
A.14
P5
12 m² P5
WG.08
C1
A.15
13 m²
WG.07
4800
5b
7200
6
G
NSW Nominated Architects: Tom Jordan 7521, Richard Leonard 7522, Robert Stent 7523, Geoffrey Hammer 5147 ABN 84 006 394 261
Builders/Contractors shall verify job dimensions before any job commences. Figured dimensions shall take precedence over scaled work. Work shall also conform to the specification, other drawings and job dimensions. All shop drawings shall be submitted to the Architect/Consultant and manufacture shall not commence prior to the return of inspected shop drawings signed by the Architect/Consultant. © Copyright 2008 All rights reserved
MINARET COLLEGE, SPRINGVALE AHD 53.27
4
A06.11
Hayball Pty Ltd 4/135 Sturt Street Southbank Victoria Australia 3006 T 03 9699 3644 F 03 9699 3708 www.hayball.com.au
PROPOSED VCE CENTRE
3450
7
NEW 1800MM HIGH FENCE. REFER TO SHEET A1.04 & A9.02 FOR DETAILS
3
A06.11
ISSUED TO CLIENT ISSUED FOR PRICING (COST PLAN C) ISSUED TO CONSULTANTS ISSUED TO CONSULTANTS
WG.12
MALE
NEW RETAINING WALL. REFER TO LANDSCAPE & CIVIL ENGINEER'S DRAWINGS
NEW 1800MM HIGH FENCE. REFER TO SHEET A1.04 & A9.02 FOR DETAILS
Rev
PRELIMINARY ISSUE
NEW UNFENCED LANDSCAPED AREA
2490
D C B A
WG.11
12 m²
CP03
P4 STAFF P3
P3
A.12
RS02
P3
RS01
P2
ADMIN
DG.12.2
3 m²
CO L
P3A
NEW RETAINING WALL. REFER TO LANDSCAPE & CIVIL ENGINEER'S DRAWINGS
REFER TO LANDSCAPE ARCHITECT'S DRAWINGS FOR DETAILS
A.18
STAFF FEMALE
CO L
PANTRY
A.10
J05
C1
WG.10
CO L
J06
P5
DG.02.4
LINE OF BULKHEAD ABOVE
RS01
E
TL01 RL 52.73
DG.18.1 CLNR
11 m² P3
P2 P3
STAFF COURT
DA.03.1
P3
P2a
A.08
A.05
A.19
J09
P4
HYD
5400
J04
P5A
2450
SC01
A.20 RS01
RS01
P3
DG.19.1
FEMALE
D
DA.15.1
P2
DDA
P3
DG.07.1
10 m²
A.02
P1b
P2
COMM
P3
DG.21.1
P2
CP05
202 m²
P2
11 m²
A.07
C1
DG.23.1
DA.14.1
7
A06.12
A.21
11 m²
A.06
C1
4 m²
C1
CP03
P5A
P3A
P3
DA.13.1
10659 CLEAR
A.04
P6
A.24 7 m²
P3 P3
MALE
RECEPTION J03
LIFT
RETRACTABLE SEATING 250 SEATS
P3
P2
A07.07 C1
LECTURE THEATRE
SC01
6
A06.12
MEETING
P5
87 m²
J02
1
CP03
WG.14
CIRCULATION
CO L
P6
7 m²
A.22
P2
813
P1b
P5A
SC01
HYD
C2
NEW 1800MM HIGH FENCE AND GATE
CO L CO L
35 m²
DG.20.1
CO L
A.03
DG.02.2
NO. 59
LOBBY DG.02.1
C1
(SINGLE STOREY BRICK BUILDING)
A08.02
DG.06.1
2
A07.06 P1
A.23
CO L
J01
P1
DG.02.3
J04
WG.06
MEETING
P5A
P2
CO L
P1
A07.06
C1
2
CO L
CO L
1
WG.01
DG.01.FHR
CO L
P1
RS02
P1B
RL 52.80
6600
WG.15
2800
P2
30 m²
144 m²
A06.12
EXISTING PAILING FENCE RETAINED
A.26
12 m²
A.01
6
J10
MEETING
A.27
56 m²
31 m²
RS03
C5
STORE
P2
A.28
CO L
SEATING STAIR
A08.01 7
EXHIBITION FOYER
CO L
DG.01.2
C
UP
A.25
P2
P2
NEW GRASSED AREA
C1
CAREERS
DG.22.FHR
A07.01
TG01
DG.22.1
A08.02
WG.02
STAIR 02
UP
DG.24.2
1
DG.24.1
3
A07.06
CO L
DG.01.1
DG.22.2
CO L
CO L
CO L
P1
ENTRY FORECOURT
BUILDING LINE O/H (TO FACE OF GLAZING SYSTEM)
2500 LANDING
5600
1
A06.11
5800 LANDING
7200
14700
5
A06.12
FW02
J12
DG.30.1
HYD
C4a
NEW SYNTHETIC TURF
C3a
32 m²
2500
P2
NEW SYNTHETIC TURF TO CONNECT TO EXISTING
FEMALE (WUDU)
P7
1150
DG.29.1
1250
TL01 P7
32 m²
STORE
J11
PASSAGE
MALE (WUDU) A.30
2 C4a
A08.01
2
A06.02 1
TG01
BUILDING LINE O/H (TO FACE OF GLAZING SYSTEM)
5
A06.12
FW02
1350
NEW LOW LEVEL PLANTING
SEAT
NEW 1800MM HIGH ACOUSTIC TIMBER PAILING FENCE. EXTENT TBC. REFER TO SHEET A1.04 & A09.02 FOR DETAILS
UP
REFER TO LANDSCAPE ARCHITECT'S DRAWINGS FOR DETAILS
A
DG.31.1
1350
FW02
NEW CONCRETE PAVEMENT
C4
1800
3
7800
A08.0101 STAIR
NEW GRASSED AREA
PROPOSED SENIOR PIAZZA
FH
DRAWINGTITLE
GENERAL ARRANGEMENT PLAN GROUND FLOOR
JG DRAWN BY SS CHECKED DATE PRINTED 6/07/2018 2:32:15 PM 1 : 100 @ A1 SCALE PROJECT NUMBER
DWG NO
2105
A03.01
N
QIBLA
REVISION
D
Excerpt from architectural drawing set / Revit 27
WORK EXPERIENCES
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
Student Architect at Skematics Architects
28
Rendering of internal spaces of proposed design / Revit
Excerpt from preliminary architectural drawing set / Revit 29
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE 30
Excerpt from preliminary architectural drawing set / Revit
Excerpt from preliminary architectural drawing set / Revit 31
:)
Thank you for your time and consideration.
34
DIAN MASHITA EDDY SURYONO // PORTFOLIO OF ARCHITECTURE
dianmashita@outlook.com // +61426629782