UF II IMPLANT ver 01 201504

Page 1

Digital Implant No.1


UFâ…Ą Implant Product Catalog

Contents Implant Surface HSA

04

Narrow

07

System Flow Chart Surgical Kit

08

Surgical Protocol

15

Regular / Wide

16

System Flow Chart Surgical Kit Surgical Protocol

19

02

13

35 44


03


UFâ…Ą Implant Product Catalog

HSA Hybrid SLA Apply the optimal morphology and roughness for osseointegration

04


11˚ A

Upper / Micro Surface Ra : 0.5~1.0㎛ Minimize Peri-Implantitis

B

Less friction around cortical bone promotes less bone loss.

Body / Macro + Micro Surface Ra : 2.0~2.5㎛ Stimulate Osseointegration

with ideal Ra.2.0~2.5㎛ promotes not only rapid osseointegration but also long-term statibility.

Advanced Surface Modification Techniques for Enhancing Osseointegration of Titanium Implant Department of dental materials, School of Dentistry, Chonnam University. Ho-jun Song, PhD Titanium oxide lm is typically consist of TiO, TiO3, TiO2. The most stable form is TiO2. Size of 1~10um, micro scale of roughness stimulates attachment and separation of osteoblast and accelerates building of extracellular matrix(ECM) and mineralization which helps to create faster osseointegration reaction. Rough surfaces increase coherence between surface of implant and mineralized bone. Hansson S, Norton M. theoretical approached and has reported that depth of 1.5um, 3~5um in diameter hemisphere pit is ideal for perfect roughness. 1) Abron A, Hopfensperger M, Thompson J, Cooper LF. Evaluation of a predictive model for implant surface topofraphy effects on early osseointefration in the rat tibia model. J Prosthet Dent 2001;85:40-6.

2) Hansson S, Norton M. The relation between surface roughness and interfacial shear strength for bone-anchored implant. A mathematical model. Journal of Biomechanics 1999;32(8):829-836.

05


UFⅡ Implant Product Catalog

Package Using Manual 1/ Taking out fixture

① Open the paper seal of the fixture ※Put the chart sticker at the back of the paper seal into the form. ② Pull the transparent window containing fixture into the arrow direction indicated on the ampoule body side and open it about 30 degree. ③ Remove the ampoule cap and turn it inducing complete connection with fixture driver. ④ Take fixture out after confirming complete connection.

※Move ampoule slowly to connect fixture completely.

2/ Separating out ampoule

3/ Taking out cover screw

① Open the transparent window containing fixture almost horizontally against ampoule body ② Shake the window left to right and completely detach ampoule body. ③ It is easy to use when detached.

A cover screw could slip down so please be careful when you remove the cap.

Fixture Driver Using Manual 1/ UF(II) Fixture Driver

2/ Recommendation Move ampoule from side to side

Move handpiece from side to side

Perfact connection

Wrong connection

Identify Hex Side Check Implantation depth (1mm)

· Recommended freguency of use : 20times · Maxinum tightening torque : 50Ncm

06

→ Easy to hold fixture completely by turning ampoule, not handpiece.


Narrow Diameter : Ø3.0 / Ø3.3 Lenght : 8.5 / 10 / 11.5 / 13 / 15 Ø3.0 Fixture : Exclusive use of Anterior tooth

ø 3.0

ø 3.3

11˚

1.7 Hex

Upper

Morse Tapered Connection 11°

2.5mm

Upper Thread Taper thread, Initial fixation

The Fixture & abutment interface ensures hermetic sealing. This distributes the load to the fixture evenly. Therefore, it minimizes bone loss.

Open Thread Fixture placement with minimum resistance. Possible to place deeper without drilling.

Straight Body

Body

Decrement of bone damage

Apical Design 15° Taper guide gradually

Cutting Edge Maximize the efficiency of self-tapping with a sharp edge.

07


UFâ…Ą Implant Product Catalog

System Flow Chart

Abutment Screw

Cemented

Angled

Temporary

Abutment

Fixture Analog

Pick-up Impression Coping

Transfer Impression Coping

Cement-Retained Restorations Temporary / Cemented / Angled Abutment

UF(II)Narrow Fixture

08

Cover Screw

Healing Abutment


Stainless Steel Housing

Single Bridge Plastic Coping

OT Cap Solid Abutment Analog

Impression Cap

Ball Abutment Analog

Protect Cap

Solid Abutment

Ball Abutment

Cement-Retained Restorations

Overdenture-Retained Restorations

Solid Abutment

Ball Abutment

UF(II)Narrow Fixture

Cover Screw

Healing Abutment

09


UFⅡ Implant Product Catalog Hex 1.7

L

UF(ll)N 3008S UF(ll)N 3010S UF(ll)N 3011S

13

UF(ll)N 3013S

15

UF(ll)N 3015S L1

Ø3.3 Hex 1.7

Hex 1.7

Apex

L

Apex L

Ø3.0

Ø3.3

Apex

Ø1.6

3308S 3310S UF(ll)NL23311S UF(ll)N 3315S L1 D

L1

15

Diameter

C6H10

Ø2.0

Cuff

Ø4.1

2

0

L1

4

2

5.5

3

C

7

4

0.5

8.5

5

10

6

H

Fixture Level

H

C

H

Ø4.2

D

Cuff/Height

0.5

D

C

C6H10

Hex 1.2

D

C

Fixture Level

Code

L

UNSCS 2700

1

UNSCS 2710

Fixture C Level

C

L

C

Level

D

D

Fixture Non-Hex Level Non-Hex Non-Hex

Hex Hex Fixture Hex Level

Hex Fixture Level

Level

Hex

Fixture Hex Level

10 Fixture

L Hex

Level

D

Fixture C Level

Non-Hex Hex 15°

L2

L2 D D

Non-HexD

D

0.5

0.5 L1

L L

UNSTA 4010N

L2

8.5 7 UNSTA 4030N D

Non-Hex

L

D

L

C

L

C

L

Non-Hex L7

L

L 5.5

L L

L7

1

UNSCA 40105H[H] UNSCA 40107H[H] UNSCA 40105N[H] UNSCAD40107N[H]

2

UNSCA 40205H[H] UNSCA 40207H[H] UNSCA 40205N[H] UNSCA 40207N[H]

3

UNSCA 40305H[H] UNSCA 40307H[H] UNSCA 40305N[H] UNSCA 40307N[H]

4

UNSCA 40405H[H] UNSCA 40407H[H] UNSCA 40405N[H] UNSCA 40407N[H]

5

UNSCA 40505H[H] UNSCA 40507H[H] UNSCA 40505N[H] UNSCA 40507N[H]

6

UNSCA 40605H[H] UNSCA 40607H[H] UNSCA 40605N[H] UNSCAL 40607N[H] L

7

D Non-Hex

Hex L 5.5

C

Non-Hex D

Hex

8.5

L1 D 8.5 D

0.5

L1

Cemented Abutment Cuff

C

D

D Non-Hex C Fixture Level Non-Hex

Hex

UNSTA 4030H7

L2

D

Ø4.0 Non-Hex

D Fixture Level

L

L

C Hex C D

3

D

L

Non-Hex

UNSTA 4010H

L

C

L

Hex

1

L

D

Non-Hex

D

Hex (Guide Pin)

L1

D1 0.5

7 8.5

L1

L2

L2

8.5

7

3

UNSCS 2730 L2

8.5

7

7

C

D

Non-Hex Hex

C Fixture HexLevel

2

· Packing unit : Abutment + Abutment Screw (UNSAS 1407H) 0.5 · Tightening torque : 20Ncm 0.5

L C

D

L

L1

L1

UNSCS 2720

Ø4.0

Cuff

L

C

D

D1

D

C

Fixture Level Fixture Level Fixture

D2

L2

D1

Hex 1.2

7

UNSHA L2 4560

D1 L2

8.5

UNSHA 4558

L2

L1

C

Fixture Level

UNSHA 4535

0.5 L1 D

D1

D2

0

7

UNSHA 4547

L1

4058

UNSHA 4060

C

Hex 1.2

11.5 4524 UNSHA 10

UNSHA 4047

L1

8.5

15 D213

L2 L2 7 D2

· Uses 1.2 Hex Driver · Tightening torque : 5 ~ 8Ncm

C

L

Fixture Fixture Level Level Fixture

8.5

UNSHA 4035

Temporary Abutment

Fixture Level

UNSHA 4520

0.5 D2 L1 D

13

10

Ø4.7

0.5 D

D1

Cuff

Hex 1.2

L Fixture Level

Ø4.6 L1

C

Hex 1.2

Fixture Level

D

UNSHA11.5 402410

0.5 D UNSHA

Cover Screw

Hex 1.2

D

L2

15

L2

D 15 13 11.5 11.5 10 15 8.5 13L2 7 11.5 D2 10 8.5 7

· Uses H 1.2 Hex / 0.5 Slot Driver · Tightening torque : 5 ~ 8Ncm

H

C

Fixture Level Fixture Level

Ø4.20.5

UNSHA 4020

7

L1

DSU 2708M

Hex 1.2

C6H10

Fixture Level

0.5Height

0.5

D

C6H10

Diameter Ø4.2

D

8.5

13

DSU 27xxM

Fixture Cuff/Height Level

H

Apex 0.5 C

D

C6H10

Ø4.2

Cuff/Height

Cuff/Height Diameter Fixture Level Hex 1.2

Apex

DSU 2708M

Cuff/Height Hex 1.2

Fixture Level

Ø4.2

DiameterApexHex 1.2

15

0.5 L1 D L2

Healing Abutment

Ø4.2

Apex Hex 1.2

D

0.5

Diameter

L2

10

Ø2.0

C6H10

Cuff/Height

L1

L

Apex D

11.5

DSU 2708M

L

Ø4.2Apex

Hex 1.2

DSU 2708M

Diameter

Ø1.9

13

L2 · Ø3.0 Fixture : Exclusive use of Anterior tooth L2 · HSA (Hybrid SLA) · Packing Unit : Fixture + Cover Screw

Apex

L2

UF(ll)N 3313SD

D

Ø2.0

Apex Apex

Apex

L1

D UF(ll)N L1 L2 UF(ll)N

Ø2.0

Ø3.3

Ø3.3

L1

DSU 27xxM

1.7

8.5 10 11.5

Ø3.3

L Ø3.0

Ø3.0

DSU 27xxM

Ø3.0 Hex 1.7

Length

DSU 27xxM DSU 2708M

Ø3.3 Ø3.0

L2

Hex

DSU 2708M

Ø3.0

Hex 1.7

UF(II) Narrow Fixture HSA

Hex 1.7

Ø2.0

Hex 1.7

L1

Hex 1.7

DSU 27xxM

Ø3.3 Hex 1.7 Hex 1.7

DSU 27xxM

HexØ3.0 1.7

Ø2.0

Hex 1.7

L D

L

1.2 Hex

UNSCA 40705H[H] UNSCA 40707H[H] UNSCA 40705N[H] UNSCA 40707N[H] 1.2 Hex

L

· Packing unit : Abutment + Abutment Screw (UNSAS 1407H) · Tightening torque : 20Ncm L

Non-Hex

L L

C

15°

L L

D

L

Fixture Level

C


Diameter Hex 1.2 Cuff/Height

Ø4.2 Ø4.2

Fixture Level

0.5

D

L

C6H10 C6H10

D

0.5 D D2

C H C

D

Fixture Level Hex

L1

Non-Hex

1.2 Hex

L2

Angled Abutment Ø4.0

C

D Hex

UNSAA 404015BH[H]

4

C

Non-Hex

UNSAAFixture 402015N[H] Level

UNSAA 402015BH[H]

2

Fixture Level Fixture Level

L

Hex B

DSU DSU27xxM 27xxM

Cuff

Hex 1.2

DSU DSU2708M 2708M

15°

D1

UNSAA

· Packing unit : Abutment + Abutment Screw (UNSAS 1407H) · Tightening torque : 20Ncm

Non-Hex

L2

8.5

7

C

L1 404015N[H]

D

D

0.5

D

Transfer Impression Coping Fixture Level L

D

C

Fixture Level

D

Ø4.0

Length

Hex (Guide Pin)

Non-Hex

L

2

13

UNSTI 4013H (UNSTI 4013S)

UNSTI 4013N

4

15

UNSTI 4015H (UNSTI 4015S)

UNSTI 4015N

6

17

UNSTI 4017H (UNSTI 4017S)

UNSTI 4017N

· Packing unit : Transfer Impression Coping + Guide Pin D

L

L

Non-Hex

D

L1

Pick Up Impression Coping L1

D

Cuff L

Fixture Level

C D Hex

Cuff

Ø2.0

Hex

C

L

Length

2

12

4

14

6

16

D

15

Ø4.0

L2

Hex (Guide Pin) L

8.5

UNSPI 4012N (UNSSG 1422)

UNSPI 4014H (UNSSG 1422)

D UNSPI 4014N (UNSSG 1422)

UNSPI 4016H (UNSSG 1425)

UNSPI 4016N (UNSSG 1425)

Dia.

L1 / L2

0.5

Ø1.5

L1 / L2

34.5 / 17.5

Par Dia. L

Ø2.0 DHF 2015SM

Fixture Analog L L

Length

Ø3.0

12

UNSFA 3012

L

D D

D

Solid Abutment Cuff

1.2 Hex

Fixture Level

C D Hex

Non-Hex

L

Fixture Level

C

D L

D

Fixture Level

C

D

7

Initial Drill

SD 1530M

30 / 15 D

10

Non-Hex

UNSPI 4012H (UNSSG 1422)

D

Starter DrillCoping + Guide Pin · Packing unit : Impression

Non-Hex

L2

L 13 11.5

L

Ø4.0 L 5.5

L7

1

UNSSA 40105

UNSSA 40107

2

UNSSA 40205

UNSSA 40207

3

UNSSA 40305

UNSSA 40307

4

UNSSA 40405

UNSSA 40407

5

UNSSA 40505

UNSSA 40507

6

UNSSA 40605

UNSSA 40607

7

UNSSA 40705

UNSSA 40707

Protect Cap

UNSAC 4005

UNSAC 4007

· Packing unit : Abutment + Protect Cap · Tightening torque : 20Ncm

L

D

11

L1 /


D

UFⅡ Implant Product Catalog

D

L

Fixture Level

C

Sta

D L L L

Plastic Coping Length

D D

10

D L1

D D D

D D

D

D L

CC

Fixture Level

C

C

L

Hex

L2

L2 L2

L2 D L2

Solid AbutmentDAnalog Length

Starter Drill Starter L1 / L2 Drill Starter Drill

7

Dia.

30 / 15 30 / 15

Impression Cap L 15°

L L

LL

C

34.5 / 17.5 34.5 / 17.5

D

Length

Fixture Level

Fixture Level Fixture Fixture Level Level

C L

D

L L C C C

C

UNSBA 3520

D D

LL

UNSBA 3530

4

L CC

UNSBA 3540

C

UNSBA 3560

Fixture Fixture 5 Level Level Fixture 6 Level

7

LL

D

D 10

UNSBAA 3510 L

Length LL L

L L

D D D

D L L L

2.6

Tap Drill Tap Diameter Tap Drill Drill

D Ø3.0 D Ø3.0 UNTD 3015 Ø3.0

Diameter Code Diameter Code Code

Ø3.3 Ø3.3 UNTD 3315 Ø3.3

Tap Drill Diameter Tap Drill Diameter

Length

L

3

Torque Wrench

Torq Ø3

UNTD UNTD Ø3

Code

UNTD 3015

UNTD

1.2 H 1.2 LengtH 1.2 H

049PCNDR8

L

*Bottom *Bottom Case Case

*Bottom Case Torque Wrench

D Ø3.0

UNTD 3015 UNTD 3015 Ø3.0

Ø4.2 UNTD 3315 UNTD UNTD 3015 3015 UNTD 3315

*Bottom Case

LL

D D

Code Code Diameter

· Packing unit : 6 Piece

· Packing unitTorque : 2 Piece Wrench

12

D

Stainless *Bottom Steel Case Housing

D D

*Bo

Ø4.0

OT Cap

L

Tap

UNSBA 3570

D D

Length

L

D D

D D

UNSBA 3550

Ball Abutment Analog

D

C

D

L

L

D D

D

3

· Packing unit : Ball Abutment + Abutment Holder D D · Tightening torque : 20Ncm

D

L L

22/1 23/1 22/1

UNSBA 3510

1 2

D D

22/1

Ø4.0

1.2 Hex

D

L

L1

L1 / L2 L1 / L2

D

1.2 Hex 1.2 Hex

C C

SDØ1.5 1530M Dia. Ø2.0 SD 1530M DHFØ2.0 2015SM Ø2.0 SD 1530M DHF DHF 2015SM 2015SM

Ball Abutment 1.2 Hex Hex 1.2

Non-Hex 1.2 Hex

D Fixture Fixture Level D Level D Fixture Level

Ini ParallelIniP L1 L1 Parallel PP L1 / L2 Parallel

Ø1.5

C

Hex

C

Dia. Dia.

L

Fixture Level

D

CC

0

23/1 23/1

UNSAI 4011

D D

D D

Fixture Level

L1 L L1 00

7 7

Ø4.0

L

11

D

L CC

SD SD 1530M 1530M

8.5 8.5

LL

L1 7

D

34.5 / 17.5 Dia. L1 / L2 Dia. L1 / L2 30 / 15 1.2 Hex

SDØ1.5 1530M Ø1.5

8.5

0.5 D 0.5 D

Starter Drill Starter L1 L1 // L2 L2 Drill UNSSAA 4007Initial Drill Ø1.5 L1 / L2 Drill Dia. Initial 30 / 15 L1 / L2 30 / 15

LL

Length

L113 11.5 L2 L2 15 10 15 13 13 11.5 11.5 L2 10 10 D D

UNSSAA 4005Initial Drill

L1 / L2 30 / 15 Dia. Dia. L1 / L2

Non-Hex

L

L1

15

0.5 D

Ø4.0

D D

5.5 D

L2

L1 L1

L1 L1

L1 (White) UNSAP 4010B Bridge L1

L1 L1 LL

L L

Ø4.0

UNSAP 4010S Single L1 (Red)

D D L

L1

L

Ø2.0

Non-Hex

Ø2.0Ø2.0

Hex

LL

DTW 0060 DTW 0060 DTW 0060

*Bottom Case

Ø4.6

8.5 / 10 / 11.5 / 13 / 15 / 18

041CAN

8.5 / 10 / 11.5 / 13 / 15 / 18 8.5 / 10 / 11.5 / 13 / 15 / 18

Torque DTW 0060 0060 Torque Wrench Wrench DTW Depth Gauge DPG 2050 Torque Wrench DTW 0060 Depth Gauge DPG 2050 Depth Gauge DPG 2050

L L

Lengt Lengt


Ø2.0

UF(II) Narrow Surgical Kit

Order Code : UF(M) 08

Parallel Pin

DSU 27xxM

DSU 2708M

Order Code : PP 2022 · PP 2023

Initial Drill

Drill

Order Code : DSU 2708M · DSU 2710M

DSU 2711M · DSU 2713M

Order Code : DHF 2015SM

Starter Drill Order Code : SD 1530M

*Bottom Case

Fixture Driver

Order Code : UNFDC 3006* · UNFDW 3006*

UNFDC 3012 · UNFDW 3012 UNFDC 3018 · UNFDW 3018

· Recommended freguency of use : 20 times · Maxinum torque : 50Ncm *Option) Available

Torque Wrench Order Code : DTW 0060

8.5 / 10 / 11.5 / 13 / 15 / 18

Depth Gauge

Tap Drill

Order Code : UNTD 3015 · UNTD 3315

1.2 Hex Screw Driver

Order Code : MD 1230 · HD 1220A

Order Code : DPG 2050

13


UFⅡ Implant Product Catalog D D D D D

L1 / L2 L2 L2 L2 L2 L2

L1 L1

L1 L1

Ø2.0 Ø2.0 Ø2.0 Ø2.0 Ø2.0Ø2.0 Ø2.0

D D D D D

L1 L1 L1 L1 L1

L2 L2 L2 L2 L2 0.5 L2 0.5 0.5 L2 0.5 0.5

D D D D D

11.5 11.5 11.5 11.5 11.5

15 15 13 13 11.5 11.5

Initial Drill 10 10 10 10 10

8.5 8.5 8.5 8.5 8.5

10 10

8.5 8.5

34.5 / 17.5 77 7 7 7

L1 / L2 22 / 10

L2 L2 L2 L2 L2

L1 L1 D1 D1 D1 D1 D1

Fixture Fixture Level Fixture Level Fixture Level Fixture Level Level Fixture Fixture Level Level

Hex Hex Hex Hex Hex

CC C D D Ø2.0C D C D C Non-Hex D 2015SM Non-Hex DHF C Non-Hex D Non-Hex D Non-Hex

Hex Hex

Non-Hex Non-Hex

Hex Hex Hex Hex Hex

LL L Ø2.0 / LØ2.7 CCL CL PP 2022 CL C D PP 2023 D D C D C Non-Hex D Non-Hex Non-Hex D Non-Hex D Non-Hex

Hex Hex

Non-Hex Non-Hex

Parallel Pin

D2 D2

L1 L1 L1 L1 L1

SD 1530M

7 7

D2 D2 D2 D2 D2

0.5 D 0.5 D

23 / 16

L2 L2

DSU 27xxM DSU 27xxM DSU 27xxM DSU 27xxM DSUDSU 27xxM DSU27xxM 27xxM

DSU 2708M DSU 2708M DSU 2708M DSU 2708M DSUDSU 2708M DSU2708M 2708M

D1 D1

77 7 7 7

8.5 8.5 8.5 8.5 8.5

7 7

8.5 8.5

Ø1.5

L2 L2

L1 / L2 13 13 13 13 13

LL L L L L L

30/15

D D

15 15 15 15 15

D D

Starter Drill

L1 L1 L1 L1 L1

D D D D D D D

Fixture Fixture Level Fixture Level Fixture Level Fixture Level Level Fixture Fixture Level Level

Drill L1 L1 L1 L1 L1 L2 L1 L2 L2 L1 L2 L2 0.5 0.5 L2 0.5 L2 0.5 0.5

L1 / L2

15° Ø2.7 15° 15° 15° DSU 2708M 15°

33 / 8.5 33 / 10 33 / 11.5 33 / 13

0.5 0.5

Fixture Fixture Level Fixture Level Fixture Level Fixture Level Level Fixture Fixture Level Level

Tap Drill

DSU 15°2710M 15°

CC DSU 2711M C C D 2713M DSU D C

Hex Hex Hex Hex Hex

D D Non-Hex D Non-Hex Non-Hex D Non-Hex D Non-Hex

Hex Hex

Non-Hex Non-Hex

L1 / L2

Ø3.0

33 / 8.5

UNTD 3015

C C

Fixture Fixture Level Fixture Level Fixture Level Fixture Level Level Fixture Fixture Level Level

Length

C C

D D

C UNTD 3315

D D D D D

Fixture Driver LL L L L L L

CC

D D D D D

Ø3.3

C C

D D

Ø3.0 / Ø3.3 Machine

Ratchet

6

UNFDC 3006*

UNFDW 3006*

12

UNFDC 3012

UNFDW 3012

18

UNFDC 3018

UNFDW 3018

*Option) Available · Recommended freguency of use : 20times · Maxinum tightening torque : 50Ncm LL L L L L L

14

D D

D D D D D D D

1.2 Hex Screw Driver Length

Ø3.0

16

MD 1230

20

D D D D D

Ø3.3 HD 1220A


Narrow Fixture Surgical Protocol

Starter Drill

Initial Drill

Drill

Tap Drill

1,200rpm

1,000rpm

800rpm

50rpm

UF(ll) Narrow Fixture 20rpm

Tap Drill

1.5mm

0.5mm

4mm

Soft Bone Medium Bone (D2, D3)

路 Recommended torque : 20 ~ 40Ncm 路 Not exceed 50Ncm

Hard Bone (D1, D2)

15


11˚

UFⅡ Implant Product Catalog

B

Regular Diameter : Ø3.8 / Ø4.0 / Ø4.5 / Ø5.0 / Ø5.5 Lenght : 7 / 8.5 / 10 / 11.5 / 13

11˚

2.5 Hex A

Upper Thread

B

2.5mm

Taper thread on straight body disperse the stress of upper part of implant. The depth of the thread getting lower toward the top improves blood supply and lessens the empty space in cortical bone to reduce if the time to create new bone.

Upper

Taper thread, Initial fixation

Morse Tapered Connection 11° The Fixture & Abutment interface ensures hermetic sealing. This distributes the load to the fixture evenly. Therefore, it minimizes bone loss.

Open Thread Fixture placement with minimum resistance. Possible to place deeper without drilling.

Straight Body Body part gets longer for long size implant which allows stable implantation without sharp change.

Body

Decrement of bone damage

Apical Design

15° Taper guide gradually With under drilling in weak bone, innitial insertion goes well as apex has 15° taper design.

Cutting Edge Maximize the efficiency of self-tapping with a sharp edge.

16


Wide Diameter : Ø6.0 / Ø6.5 / Ø7.0 Lenght : 6.5 / 7 / 8.5 / 10 / 11.5 Length 6.5 Fixture : Exclusive use of posterior

30˚

Platform Switching Design

Open thread Fixture placement with minimum resistance. Possible to place deeper without drilling.

Body thread UF(II) Body Thread design

Conical Seal Connection

Cutting edge

Taper 11˚ Hex 2.5 compatible with UF(II) Regular prosthetics.

Maximize the efficiency of self-tapping with a sharp edge.

· Length 6.5 Fixture : Exclusive use of posterior

17


UFâ…Ą Implant Product Catalog

Regular / Wide

Abutment Screw

Cemented

Angled

Mill

UCLA Gold/CCM

UCLA Plastic

Abutment

Fixture Analog

Pick-up Impression Coping

Transfer Impression Coping

Cement-Retained Restorations Temporary / Cemented / Mill / Angled Abutment

Screw-Retained Restorations UCLA Gold / CCM / UCLA Plastic Abutment

UF(II) Regular Fixture

18

UF(II) Wide Fixture

Cover Screw

Healing Abutment

Temporary


System Flow Chart

O-Ring

Stainless Steel Housing

Retainer Ball Cap

OT Cap

Single Bridge Plastic Coping

Denture Cap

Dalbo Plus

Male

Solid Abutment Analog

Ball Abutment Analog

Impression Cap

Protect Cap Solid Abutment Ball Abutment

Cement-Retained Restorations

Overdenture-Retained Restorations

Solid Abutment

Ball Abutment

UF(II) Regular Fixture

UF(II) Wide Fixture

Cover Screw

Locator

Healing Abutment

19


UFâ…Ą Implant Product Catalog

Regular / Wide

Cylinder Screw

Cemented Cylinder

Gold Cylinder

Plastic Cylinder

Temporary Cylinder

Octa Abutment Analog

Pick-up Impression Coping

Transfer Impression Coping

Octa Abutment

Healing Cap

Screw-Retained Restorations Octa Abutment

UF(II) Regular Fixture

20

UF(II) Wide Fixture

Cover Screw

Healing Abutment


System Flow Chart

Cylinder Screw

Gold Cylinder

Plastic Cylinder

Temporary Cylinder

Conical Abutment Analog

Pick-up Impression Coping

Healing Cap

Transfer Impression Coping

Conical Abutment

Multiunit Abutment

Screw-Retained Restorations Conical / Multiunit Abutment

UF(II) Regular Fixture

UF(II) Wide Fixture

Cover Screw

Healing Abutment

21


UFⅡ Implant Product Catalog

UF(II) Regular Fixture

Hex 2.5 Hex 2.5

Hex

Hex 2.5

Length

D D

2.5 L L

Ø3.8

Ø4.0

Ø4.5

Ø5.0

Ø5.5

7

-

-

UF(ll) 4507S

UF(ll) 5007S

UF(ll) 5507S

8.5

UF(ll) 3808S

UF(ll) 4008S

UF(ll) 4508S

UF(ll) 5008S

UF(ll) 5508S

10

UF(ll)D 3810S

UF(ll) 4010S

UF(ll) 4510S

UF(ll) 5010S

UF(ll) 5510S

11.5

UF(ll) 3811S

UF(ll) 4011S

UF(ll) 4511S

UF(ll) 5011S

UF(ll) 5511S

13

UF(ll) 3813S L

UF(ll) 4013S

UF(ll) 4513S

UF(ll) 5013S

UF(ll) 5513S

Ø2.2

Ø2.6

Ø3.1

Ø3.7

Ø2.1

Apex Apex Apex

Apex

UF(II) Wide Fixture Hex 2.5

Hex

D

Length

2.5

Apex

UF(ll) 6506S

UF(ll) 7006S

UF(ll) 6507S

UF(ll) 7007S

8.5

UF(ll) 6008S

UF(ll) 6508S

UF(ll) 7008S

UF(ll) 6010S

UF(ll) 6510S

UF(ll) 7010S

UF(ll) 6011S

UF(ll) 6511S

UF(ll) 7011S

L Ø5.4

Ø5.9

Ø6.4

D

Apex

· Length 6.5 Fixture : Exclusive use of posterior Apex

Apex

Hex 2.5

D

L

Apex

22

Ø7.0

UF(ll) 6007S

11.5 L

Ø6.5

UF(ll) 6006S

10

L

Ø6.0

7

6.5 D

Hex 2.5


Cover Screw Hex 1.2

Cuff

Fixture Level

Hex 1.2 Hex 1.2

Cuff

Code

0

SSCS 3400

1

SSCS 3410

2

SSCS 3420

3

SSCS 3430 D

Cuff

Fixture Level

Cuff

Fixture Level

· Uses 1.2 Hex / 0.5 Slot Driver · Tightening torque : 5 ~ 8Ncm · Used for narrow area after the Implant surgery or to protect Implant connection area. L Screw installation after removing the remaining blood or foreign substance in Implant.

Cuff

Cuff Cuff

2

Hex 1.2

Fixture Level

D1 H

Hex 1.2 Height

C

Diameter

Ø4.5

Ø4.5

H2 Hex 1.2 Height

D1

H2

D1

D2

H C

Fixture Level

H C

Fixture Level Cuff/Height C1H2

Hex 1.2 Diameter

C

Fixture Level

H

D2

Cuff/Height

Hex 1.2 Diameter Fixture Level

D1 D2

8.0

C1H2

Cuff/Height

8.0 Hex 1.2 Diameter

D1 D2

C1H2

SSHA 4040

SSCØ2.25 2008SH

SSCØ2.45 2008H

SSHA 4060Ø2.25

Ø2.45

SSHA 4080

SSC 2008SH

Diameter Fixture Level

C

· Suitable for a small diameter abutment like a Ball Abutment. · Recommended to use it when Fixture is deeply inserted. SSC 2008SH · Uses 1.2 Hex / 0.5 Slot Driver ·Tightening torque:SSC 5 ~2008H 8Ncm

Ø4.5 H2

C

SSHA 4020

8

Fixture Level Diameter

Height

Fixture Level

6

C

L

Ø2.45

Ø4.0

Fixture Level

4

D

C

Hex 1.2

Ø2.25

2

D

2

Hex 1.2

L

Healing Abutment

C Fixture Level

D

D

2

Hex 1.2

C

D

Fixture Level

Cuff

8.0

C

H

D1 C

Fixture Level D2 D2

H

SSC 2008H

Height

Cuff

D1 - Ø4.6 D2 - Ø4.5

D1 - Ø5.6 D2 - Ø5.5

D1 - Ø6.6 D2 - Ø6.5

D1 - Ø7.6 D2 - Ø7.5

2

0

SSHA 4520

SSHA 5520

SSHA 6520

SSHA 7520

4

2

SSHA 4524

SSHA 5524

SSHA 6524

SSHA 7524

5.5

3

SSHA 4535

SSHA 5535

SSHA 6535

SSHA 7535

7

4

SSHA 4547

SSHA 5547

SSHA 6547

SSHA 7547

Height

Cuff

2

1

3

2

SSHA 8223

4

3

SSHA 8234

5

4

SSHA 8245

D

D1 - Ø8.2 D2 - Ø8.0 Fixture Level

- Ø9.2 D2 - Ø9.0

LD1 C

D

SSHA 8212

SSHA 9212 D

SSHA 9223 Ø2.25

L SSHA 9234

Ø2.45

L

SSHA 9245 C

Fixture Level

C · Uses 1.2 Hex / 0.5 Slot DriverFixture·Level Tightening torque : 5 ~ 8Ncm · Used after the one-stage surgery or second-stage surgery and it takes the role which forms the gingiva and it helps to form the gingiva to make an emergency prole. Ø2.25 Ø2.45 - Choices available depend on the patient’s height ofSSC gingiva SSC 2008SH 2008H and the size of abutment. Ø2.25 Ø2.45 (Healing Abutment should have wider diameter than the desired abutment. That way the abutment will be installed without interruption from the gingival and the balance of the nalized prosthesis will be ensured.) SSC 2008SH

SSC 2008H SSC 2008SH

SSC 2008H

Temporary Abutment C

Fixture Level

Cuff

D Hex

Non-Hex C

Fixture Level

C

Fixture Level D Hex

Non-Hex Hex

D Non-Hex

Ø4.5 Hex

Non Hex

1

SSTA 4510H[H]

SSTA 4510N[H]

3

SSTA 4530H[H]

SSTA 4530N[H]

· Uses 1.2 Hex / 0.5 Slot Driver · Used in prosthetic fabrication · Packing Unit : Abutment + Abutment Screw (SSC 2008H) · Tightening torque : 30 ~ 35Ncm

23


UFⅡ Implant Product Catalog

Cemented Abutment Hex Type Length Cuff D

4

Fixture Level

Ø2.25

Ø2.45

Ø2.25

Ø2.45

SSC 2008SH

SSC 2008H

SSC 2008SH

Ø5.5

Ø6.5

1

SSCA 45104H(ll)[H]

SSCA 55104H(ll)[H]

SSCA 65104H(ll)[H]

SSCA 75104H(ll)[H]

2

SSCA 45204H(ll)[H]

Fixture LevelSSCA 65204H(ll)[H] SSCA 55204H(ll)[H]

SSCA 75204H(ll)[H]

3

SSCA 45304H(ll)[H]

SSCA 55304H(ll)[H]

SSCA 75304H(ll)[H]

4

SSCA 45404H(ll)[H]

SSCA 55404H(ll)[H]

5

SSCA 45504H(ll)[H]

SSCA 55504H(ll)[H]

C

1

SSCA 45105H(ll)[H]

L

2

L D Fixture Level

Ø4.5

C

5.5

7

SSC 2008H

Ø7.5 C

SSCA 65304H(ll)[H] D

SSCA 65404H(ll)[H]C

SSCA 75404H(ll)[H]

SSCA 65504H(ll)[H]

SSCA 75504H(ll)[H]

SSCA 55105H(ll)[H]

SSCA 65105H(ll)[H]

SSCA 75105H(ll)[H]

SSCA 45205H(ll)[H]

SSCA 55205H(ll)[H]

SSCA 65205H(ll)[H]

SSCA 75205H(ll)[H]

3

SSCA 45305H(ll)[H]

SSCA 55305H(ll)[H]

SSCA 65305H(ll)[H]

SSCA 75305H(ll)[H]

4

SSCA 45405H(ll)[H]

SSCA 55405H(ll)[H]

SSCA 65405H(ll)[H]

SSCA 75405H(ll)[H]

5

SSCA 45505H(ll)[H]

SSCA 55505H(ll)[H]

SSCA 65505H(ll)[H]

SSCA 75505H(ll)[H]

1

SSCA 45107H(ll)[H]

Fixture LevelSSCA 65107H(ll)[H] SSCA 55107H(ll)[H]

SSCA 75107H(ll)[H]

2

SSCA 45207H(ll)[H]

SSCA 55207H(ll)[H]

SSCA 65207H(ll)[H]

SSCA 75207H(ll)[H]

3

SSCA 45307H(ll)[H]

SSCA 55307H(ll)[H]

SSCA 65307H(ll)[H]C

SSCA 75307H(ll)[H]

4

SSCA 45407H(ll)[H]

SSCA 55407H(ll)[H]

SSCA 65407H(ll)[H]

SSCA 75407H(ll)[H]

5

SSCA 45507H(ll)[H]

SSCA 55507H(ll)[H]

SSCA 65507H(ll)[H] D

SSCA 75507H(ll)[H]

SSC 2008SH

SSC 2008H

SSC 2008H

SSC 2008H

Ø4.5

Ø5.5

Ø6.5

Ø7.5

1

SSCA 45104N(ll)[H]

SSCA 55104N(ll)[H]

SSCA 65104N(ll)[H]

SSCA 75104N(ll)[H]

2

SSCA 45204N(ll)[H]

SSCA 55204N(ll)[H]

SSCA 65204N(ll)[H]

SSCA 75204N(ll)[H]

3

SSCA 45304N(ll)[H]

SSCA 55304N(ll)[H]

SSCA 65304N(ll)[H]

SSCA 75304N(ll)[H]

4

SSCA 45404N(ll)[H]

C SSCA 65404N(ll)[H]

SSCA 75404N(ll)[H]

5

SSCA 45504N(ll)[H]

Fixture SSCA 55404N(ll)[H] Level

SSCA 55504N(ll)[H]

SSCA 65504N(ll)[H]

SSCA 75504N(ll)[H]

1

SSCA 45105N(ll)[H]

SSCA 55105N(ll)[H]

D SSCA 65105N(ll)[H]

SSCA 75105N(ll)[H]

2

Hex SSCA 45205N(ll)[H] LevelSSCA 55205N(ll)[H]

3

SSCA 45305N(ll)[H]

SSCA 55305N(ll)[H]

4

SSCA 45405N(ll)[H]

SSCA 55405N(ll)[H]

5

SSCA 45505N(ll)[H]

SSCA 55505N(ll)[H]Hex (A Type) SSCA 65505N(ll)[H]

SSCA 75505N(ll)[H]

1

SSCA 45107N(ll)[H]

SSCA 55107N(ll)[H]

SSCA 65107N(ll)[H]

SSCA 75107N(ll)[H]

2

SSCA 45207N(ll)[H]

SSCA 55207N(ll)[H]Hex (BType) SSCA 65207N(ll)[H]

SSCA 75207N(ll)[H]

3

SSCA 45307N(ll)[H]

SSCA 55307N(ll)[H]

SSCA 65307N(ll)[H]

SSCA 75307N(ll)[H]

4

SSCA 45407N(ll)[H]

SSCA 55407N(ll)[H]

SSCA 65407N(ll)[H]

SSCA 75407N(ll)[H]

5

SSCA 45507N(ll)[H]

SSCA 55507N(ll)[H]

SSCA 65507N(ll)[H]

SSCA 75507N(ll)[H]

SSC 2008SH

SSC 2008H

SSC 2008H

SSC 2008H

Screw

Fixture Level

D

C

D

Fixture Level

Non-Hex Type Length Cuff

D

L D C

Fixture Level

4

L

Fixture Level

Ø2.25

Ø2.45

C

5.5 Ø2.25 SSC 2008SH

SSC 2008SH

Ø2.45 SSC 2008H

SSC 2008H

7

Screw

Fixture

Hex

C Non-Hex SSCA 65205N(ll)[H]

SSCA 75205N(ll)[H]

SSCA 65305N(ll)[H]

SSCA 75305N(ll)[H]

SSCA 65405N(ll)[H]

SSCA 75405N(ll)[H]

D

Non-Hex

Hex (A Type)

Hex (BType)

· Used to make ordinary cement type prosthesis. · For the esthetics, gingiva area is colored in gold. · To prevent rotation of prosthesis it has a at side. · Uses 1.2 Hex driver · Packing Unit : Abutment + Abutment Screw (SSC 2008H) ※Ø4.5 Abutment (SSC 2008SH) · Tightening torque : 30 ~ 35Ncm · Compatitable with Solid Abutment Impression Cap

24


Mill Abutment Hex Type

C

Fixture Level C

Fixture Level

C

Fixture Level

Cuff

Ø4.0

Ø4.5

4

SSMA 4015H[H]

3

Fixture Level

SSMA 6530H[H]

C SSMA 7530H[H]

C

Fixture Level

D

Non-Hex Type

Fixture Level

Cuff

Ø4.0

1.5

SSMA 4015N[H]

C

Fixture Level C

Hex Ø5.5

D Non-Hex

Hex

Non-Hex

D

D D

Ø6.5

Ø7.5

SSMA 4520N[H] SSMA 5525N[H]

2.5

SSMA 6530N[H] SSMA 7530N[H]

3

C

D C Non-Hex

D Hex

Ø4.5

2

Fixture Level

Ø7.5

SSMA 5525H[H]

2.5 D

Ø6.5

SSMA 4520H[H]

2

D

Fixture Level

Ø5.5

· Used for when high customization in abutment path and prosthetic margins are needed. · Secure tapered connection construction · Gold colored for aesthetic design · Uses 1.2 Hex Driver · Packing contents : Abutment + Abutment Screw (SSC2008H) · Tightening torque : 30 ~ 35Ncm L L Fixture Level

Angled Abutment Angled Type

15˚

L

Fixture Level

1.5

Ø4.5 3

Fixture Level

2

D D Hex

Hex

D Non-Hex

Hex

Non-Hex

Non-Hex 4

5

Hex A

SSAA 451515AH[H] SSAA 452015AH[H] SSAA 453015AH[H] SSAA 454015AH[H] SSAA 455015AH[H]

Hex B

SSAA 451515BH[H] SSAA 452015BH[H] SSAA 453015BH[H] SSAA 454015BH[H] SSAA 455015BH[H]

Non-Hex SSAA 451515N[H] SSAA 452015N[H] SSAA 453015N[H] SSAA 454015N[H] SSAA 455015N[H]

Fixture Level Fixture Level

C

Fixture Level

C

25˚

D

Hex

Non-Hex D

Hex

Non-Hex

Hex (BType)

SSAA 451525BH[H] SSAA 452025BH[H] SSAA 453025BH[H] SSAA 454025BH[H] SSAA 455025BH[H]

Angled Type

Hex (A Type)

Hex (BType)

Hex B

Non-Hex

Hex (A Type)

Hex (A Type)

SSAA 451525AH[H] SSAA 452025AH[H] SSAA 453025AH[H] SSAA 454025AH[H] SSAA 455025AH[H]

Non-Hex SSAA 451525N[H] SSAA 452025N[H] SSAA 453025N[H] SSAA 454025N[H] SSAA 455025N[H]

C D Hex

Hex A

15˚

1.5

2

Ø5.5 3 Fixture Level

L

4

L

5

L

Hex A

SSAA 551515AH[H] SSAA 552015AH[H] SSAA 553015AH[H] SSAA 554015AH[H] SSAA 555015AH[H]

Hex B

D SSAA 551515BH[H] SSAA 552015BH[H] SSAA 553015BH[H] SSAA 554015BH[H] SSAA 555015BH[H]

Fixture Level Fixture Level

D Non-Hex SSAA 551515N[H] SSAA 552015N[H] SSAA 553015N[H] SSAA 554015N[H] SSAA 555015N[H]

Hex (BType)

25˚

Hex A

D SSAA 551525AH[H] SSAA 552025AH[H] SSAA 553025AH[H] SSAA 554025AH[H] SSAA 555025AH[H]

Hex B

SSAA 551525BH[H] SSAA 552025BH[H] SSAA 553025BH[H] SSAA 554025BH[H] SSAA 555025BH[H]

Non-Hex SSAA 551525N[H] SSAA 552025N[H] SSAA 553025N[H] SSAA 554025N[H] SSAA 555025N[H] · Used to modify the xture’s path and mainly used for anterior teeth. · Depending on the angle slope, it is categorized into 15° and 25° Angled Abutment. · Availability of A type and B type of hex part overcomes the limitation of direction of abutment. · For the esthetics, Gingiva area is colored in gold. · Uses 1.2 Hex Driver 정상적인 체결 Proper connection · Packing contents : Abutment + Abutment Screw (SSC2008H) 정상적인 체결 · Tightening torque : 30 ~ 35Ncm Proper connection 정상적인 체결

Proper connection

25


UFⅡ Implant Product Catalog

UCLA Abutment Gold Type Ø4.5

Cuff

Hex

Non Hex

1

SSGA 4510H[H]

SSGA 4510N[H]

3

SSGA 4530H[H]

SSGA 4530N[H]

· Screw retained type abutment which uses abutment screw to fix prosthesis. · Can be used when there is limitation on path, esthetics, space etc. (It is directly casted on abutment to make inner part of prosthesis. Due to this aspect, Customized abutment can be made which can be applied to variety of cases. Especially, it is very strong for cases which requires difficult angle modication.) · After the customization, Dental gold metal will be casted with it to make prosthesis. · Melting range on cylinder area : 1400 ~ 1450℃ (Obligation on non-mineral of noble or metal -free alloy Casting) · Depending on the connecting method with fixture, it is categorized as Hex / Non – Hex · Uses 1.2 Hex Driver · Tightening torque : 30 ~ 35Ncm · Packing contents : Abutment + Abutment Screw (SSC2008H) C

Fixture Level

CCM Type

D Fixture Level

Hex

C

Non-Hex D

Hex

Ø4.0

Cuff

Non-Hex

Hex

Ø4.5 Non Hex

Hex

Non Hex

1

CCSS 4010H[H] CCSS 4010N[H] CCSS 4510H[H] CCSS 4510N[H]

3

CCSS 4530H[H] CCSS 4530N[H]

· After the customization, it is casted with dental alloy (Gold / non-precious metal alloy) to make prosthesis. · Depending on the connecting method with fixture, it is categorized as Hex / Non – Hex · Uses 1.2 Hex Driver · Packing Unit : Abutment + Abutment Screw (SSC2008H) · Tightening torque : 30 ~ 35Ncm

Plastic Type

L

Length

Fixture Level

L

12

D Fixture Level

Hex

Non-Hex

Non-Hex

L

Fixture Level

L D

Fixture Level D

26 정상적인 체결

Proper connection

Ø5.5 Non Hex

Hex

Non Hex

SSPA 4512H[H] SSPA 4512N[H] SSPA 5512H[H] SSPA 5512N[H]

· Its purpose of usage is the same as UCLA Gold Abutment but material for the abutment is plastic. · Compared to UCLA Gold Abutment, its degree of precision or accuracy on connection area with abutment is slightly lower. · After the customization, it is casted with dental alloy (Gold / non-precious metal alloy) to make prosthesis. · Uses 1.2 Hex Driver · Packing contents : Abutment + Abutment Screw (SSC2008H) · Tightening torque : Tightening smoothly before casting, 30 ~ 35Ncm after casting

D Hex

Ø4.5 Hex


L L L Fixture Level Fixture Level Fixture Level

D D D Non-Hex Non-Hex Non-Hex

Hex Hex Hex

Pick up Impression Coping Hex Type Height L L L Fixture Level Fixture Level Fixture Level

D D D

Ø4.0

Ø4.5

Ø5.5

Ø6.5

Guide Pin

09

SSPI 4009H SSPI 4509H SSPI 5509H SSPI 6509H

SSG 2021

13

SSPI 4013H SSPI 4513H SSPI 5513H SSPI 6513H

SSG 2026

17

SSPI 4017H SSPI 4517H SSPI 5517H SSPI 6517H

SSG 2329

19

SSPI 4019H SSPI 4519H SSPI 5519H SSPI 6519H

SSG 2329

Non-Hex Type Height

정상적인 체결 정상적인 체결 Proper connection 정상적인 체결 Proper connection

Ø4.0

Ø4.5

Ø5.5

Ø6.5

Guide Pin

09

SSPI 4009N SSPI 4509N SSPI 5509N SSPI 6509N

SSG 2021

13

SSPI 4013N SSPI 4513N SSPI 5513N SSPI 6513N

SSG 2026

17

SSPI 4017N SSPI 4517N SSPI 5517N SSPI 6517N

SSG 2329

19

SSPI 4019N SSPI 4519N SSPI 5519N SSPI 6519N

SSG 2329

· Custom tray is used for pick-up type of impression taking · Uses 1.2 Hex Driver. · Packing contents : Impression Coping + Guide Pin

Proper connection

Transfer Impression Coping Hex Type Height L L D

L

10 Guide Pin 15 Guide Pin

Ø4.0

Ø4.5

Ø5.5

SSTI 4010H SSTI 4510H SSTI 4015S SSTI 4015H SSTI 4515H SSTI 4020S

Ø6.5

SSTI 5510H SSTI 6510H SSTI 6515S SSTI 5515H SSTI L 6515H SSTI 6520S L

D

L

D

Non-Hex Type L

Height

Ø4.0

Ø4.5

Ø5.5

Ø6.5

L

10

SSTI 4010N

SSTI 4510N

SSTI 5510N

SSTI 6510N

15

SSTI 4015N

SSTI 4515N

SSTI 5515N

SSTI 6515N

L D D D

· Ready-made tray is used for transfer type of impression taking. · Double sided structure increases quality. · Hex type is two-piece structure and Non-Hex type is one-piece structure. · Uses 1.2 Hex Driver · Packing contents : Impression Coping + Guide Pin L L

L L D D

L

Fixture Analog

L

Height

Ø4.0

12

SSFA 4012

· Providing anchor point for fabricating implant prosthetics on working model.

D

27 L


L

UFⅡ Implant Product Catalog D

Solid Abutment Length

4 D

Hex 1.2

L

5.5

C

7

Cuff

Ø4.5

Ø5.5

Ø6.5

Ø7.5

1

SSSA 45104

SSSA 55104

SSSA 65104

SSSA 75104

2

SSSA 45204

SSSA 55204

SSSA 65204

Single SSSA

3

SSSA 45304

SSSA 55304

SSSA 65304

SSSA 75304

4

SSSA 45404

SSSA 55404

SSSA 65404

SSSA 75404

5

SSSA 45504

SSSA 55504

SSSA 65504

SSSA 75504

1

SSSA 45105

SSSA 55105

SSSA 65105

SSSA 75105

2

SSSA 45205

SSSA 55205

SSSA 65205

SSSA 75205

3

SSSA 45305

SSSA 55305

SSSA 65305

SSSA 75305

4

SSSA 45405

SSSA 55405

SSSA 65405

SSSA 75405

5

SSSA 45505

SSSA 55505

SSSA 65505

SSSA 75505

1

SSSA 45107

SSSA 55107

SSSA 65107

SSSA 75107

2

SSSA 45207

SSSA 55207

SSSA 65207

SSSA 75207

3

SSSA 45307

SSSA 55307

SSSA 65307

SSSA 75307

4

SSSA 45407

SSSA 55407

SSSA 65407

SSSA 75407

5

SSSA 45507

SSSA 55507

SSSA 65507

SSSA 75507

L

Bridge 75204

D

L

· This is a cemented type abutment which uses dental cement to fix the prosthesis. · Abutment and screw are in one-piece structure. · Taking impression at abutment level. · Considering the esthetics, gingival is colored in gold. · Uses 1.2 Hex / Solid Abutment Driver · Packing contents : Abutment + Protect Cap · Tightening torque : 30 ~ 35Ncm L

Protect Cap

L

L

Length

Ø4.5

Ø5.5

Ø6.5

D

Ø7.5

4

SSAC 4504

SSAC 5504

SSAC 6504C

SSAC 7504

5.5

SSAC 4505

SSAC 5505

SSAC 6505

SSAC 7505

7

SSAC 4507

SSAC 5507

SSAC 6507

D

SSAC 7507

C D

· Used to protect abutment in the patient’s mouth and minimize the discomfort for the patient. · Can be applied to substructure of temporary prosthesis. · Convenient locking mechanism. C

Impression Cap L

L

L

L

Length

Ø4.5

Ø5.5

Ø6.5

4

SSAI 4511

SSAI 5511

SSAI 6511

Guide Pin

○ White

● Red

● Green

D

Ø7.5 SSAI 7511L ● Blue D

· Used to take impression of Solid Abutment. L · Different coloring provides easy identification on types of abutment diameter. · Convenient locking mechanism. D

Plastic Coping Length Color 10

L

Red

L

Ø4.5

Ø5.5

Ø6.5

Bridge

Single

28

L

White SSAP 4510B SSAP 5510B SSAP 6510B SSAP 7510B D

Non-Octa

· Can be used as prosthesis’ frame work by installing Solid Abutment Analog. · Dierent coloring provides easy identication on types of case. · Packing contents : Plastic Coping D Octa

L Non-Octa

Bridge L Octa

Single

D

SSAP 4510S SSAP 5510S SSAP 6510S SSAP 7510S Octa

Single

Ø7.5

Non-Octa

Bridge L

L


L Octa Single

Non-Octa

Bridge

L

Analog D

L

D

Length

Ø4.5

Ø5.5

Ø6.5

Ø7.5

4

SSAA 4504

SSAA 5504

SSAA 6504

5.5

SSAA 4505

SSAA 5505

SSAA 6505

7

SSAA 4507

Color

-

SSAA 5507 ● Red

SSAA 6507 ● Green

SSAA 7504

Octa

Non-Octa

SSAA 7505 SSAA 7507 ● Blue

· Solid Abutment is formed on working model. · Dierent coloring provides easy identication on types of abutment diameter. · Packing Unit : Solid Abutment Analog L

Octa Abutment

D D C C

DD

D

Cuff

Ø4.8

Ø6.0

Ø6.5

1.5

SSOA 4815

SSOA 6015

SSOA 6515

2.5

SSOA 4825

SSOA 6025

SSOA 6525

3.5

SSOA 4835

SSOA 6035

SSOA 6535

4.5

SSOA 4845

SSOA 6045

SSOA 6545

D D

5.5

SSOA 4855

SSOA 6055

SSOA 6555

DD

L L LL

· Designed abutment to use prosthesis by turning the internal connection xture into external connection xture type with cylinder. · Used to create screw retained prosthesis on poor path bridge case. · Uses Octa Abutment Driver(HD 3006A / HD 3012A). · Packing contents : Abutment + Holder *Holder installation: Convenient to install in patient’s mouth. · Tightening torque : 30 ~ 35Ncm

CC

L L

Healing Cap L L D D

LL

Length

Ø5.2

Ø7.0

4

HCI 48504

HCI 65704

LL

D D DD

· To protect Octa Abutment in oral, and minimize the discomfort for patient. · Uses 1.2 Hex Driver · Packing Unit : Healing Cap + Cylinder Screw (STI 2004H) · Tightening torque : 20Ncm

DD

L L

Gold Cylinder Length L L D D

LL

DD Octa Octa

Non-Octa Non-Octa

Octa Octa

Non-Octa Non-Octa

4

Type

Ø5.0

Ø6.2

LL

Ø6.5

Octa

AGI 48504[H]

AGI 60004[H]

AGI 65704[H]

Non-Octa

AGI 48504N[H]

AGI 60004N[H]

AGI 65704N[H]

· After the customization, Dental gold metal will be casted with it to make prosthesis.. · Cylinder fusion range : 1400 ~ 1450℃ D (Non-precious metal alloy are not allowed for casting) D · Uses 1.2 Hex Driver · Packing contents : Gold Cylinder + Cylinder Screw (STI 2004) DD ·Tightening torque : 20Ncm

L L D D

Octa Octa

DD Non-Octa Non-Octa

Octa Octa

Non-Octa Non-Octa

LL

10

Type

DD

L L LL

Plastic Cylinder Length

D D

Ø5.0

Ø6.3

Ø7.0

Octa

API 48514[H]

API 60714[H]

API 65714[H]

Non-Octa

API 48514N[H]

API 60714N[H]

API 65714N[H]

· After the customization, Dental alloy (Gold, Non-precious metal alloy) will be casted with it to make prosthesis. · Less accuracy on connecting part compared to Gold Cylinder. · Uses 1.2 Hex Driver · Tightening torque: 20Ncm · Packing contents : Plastic Cylinder + Cylinder Screw (STI 2004)

29 D


L

UFⅡ Implant Product Catalog D Octa

Non-Octa

Temporary Cylinder Length L

10

Type

D

Ø5.0

Octa

ITC 48010[H]

Non-Octa

ITC 48010N[H]

Ø6.0

ITC 60010[H] C

Fixture Level

ITC 60010N[H]

· Uses 1.2 Hex Driver · Packing contents : Temporary Cylinder + Cylinder Screw (STI 2004) · Tightening torque : 20Ncm

D

D

Cemented Cylinder Lenght 8

L

D

9

L

D

Type

Ø5.0

Ø5.8

D Ø6.4

Octa

ICC 48508[H]

ICC 48588[H]

Non-Octa

ICC 48508N[H]

ICC 48588N[H]

D D

Octa

ICC 60649[H] L

ICC 65309[H]

Non-Octa

ICC 60649N[H]

ICC 65309N[H]

· Uses 1.2 Hex Driver · Packing contents : Cemented Cylinder + Cylinder Screw (STI 2004H) · Tightening torque : 20Ncm

L L

Ø6.9 L

L L

D D Ø5.0

L

D

L

L

D

L D

Pick-up Impression Coping Lenght 10

2

Type

Ø5.7

Ø5.0 Ø6.4

Ø7.0

Octa

IPI 48610

Ø5.0607102 IPI

Non-Octa

IPI 48610N

IPI 60710N

IPI 65710

Ø5.0

· Pick-up type impression-taking process using custom tray. · Asymmetry structure to minimize close interruption · Uses 1.2 Hex Driver · Packing contents : Impression Coping + Guide Pin

Ø5.0

4 2

Ø5.0

2

Ø5.0

IPI 65710N

4 Ø4.5

Ø5.0

D

4

L

4 Ø4.5

D

L

Transfer Impression Coping Lenght

L

D

D

D

D D

L

D D

10

Ø5.0 IOTI 48010

Ø6.1 IOTI 60010

· Transfer type impression taking process using ready-made tray · Double sided structure which elevates the quality · Uses 1.2 Hex Driver · Packing contents : Impression Coping + Guide Pin

L

IOTI 65010

Ø4.6 3 Ø4.6 3 Ø4.6 Ø4.2

Abutment Analog Lenght

L

Ø4.5

Ø4.2 Ø4.6

L

L

Ø6.6

Ø4.5

10

Ø4.8

Ø6.0 RCI 60014

RCI 48014

2.6 3 3 2.6

Ø4.2 Ø4.2

2.6 2.6

· Provides anchor point for fabricating Octa Abutment conguration. · Packing contents : Octa Abutment Analog

30 D

C

Ø6.5 RCI 65014


3 D

Ø4.2 L

2.6

Ball Abutment

D

Ø3.5

1

SSBA 3510

2

SSBA 3520

3

SSBA 3530

4

SSBA 3540

5

SSBA 3550

6

SSBA 3560

C

· Used to create over-denture for edentulous patient. · Used when fixed type Implant prosthesis is difficult due to severe bone or soft tissue loss. · Post part is colored in gold. · Path recovery to the maximum of 20° · Uses Ball Abutment Driver (HD 2406A / HD 2412A) · Packing contents : Abutment + O-Ring (1 Piece) + Holder *Holder installation : Convenient to install in patient’s mouth · Tightening torque : 30 ~ 35Ncm

C

Fixture Level

Lenght

D

Ball Abutment Analog D L

Lenght

Ø3.5

10

SABA 3510

· Provides anchor point for ball abutment on working model. · Packing Unit : Analog

D

L

D

Dalbo Plus

L

Code

D L Ø5.0 L

2

DBPM 201

· Double structure with titanium housing and precious metallic insert. · Provides long term usage about 10,000 trials due to its resistance to abrasion. · Minimum abrasion to the Ball Abutment and to the insert. · Simple and convenient retention. · Up to 20° in insertion angle exibility. · Compatible with all DIO Implant System.

Ø5.0 2

Retainer

Ø5.0 Ø5.0 4 Ø5.0

Code

Ø5.0

Ø5.0

RT 0502

· Advantageous when occlusal distance is low compare to Ball Cap. · Packing contents : Retainer + O-Ring (2 Piece)

2 4 2 Ø4.5

Ø5.0

2

Ball Cap

4 Ø4.5

Ø5.0

Code

4

Ø5.0

BC 5004

· Outstanding consistency and Clip-on · Packing Unit : Ball Cap + O-Ring (Black & Orange)

Ø4.5 4 Ø4.6 3

Ø4.5

O-Ring

Ø4.6

Code

3

Ø4.5 Ø4.2 Ø4.6 2.6

3

Ø4.2

OR 0450 B (Black) / OR 0450 O (Orange)

· Black : Laboratory used for fabrications with high retention. · Orange : For clinical use (Over 6Ncm) · Package Contents : O-Ring (1 Piece)

Ø4.6 2.6 3 Ø4.6 Ø4.2 3

2.6

Ø4.2 2.6

31


2

Ø5.0

4

Ø5.0

2

UFⅡ Implant Product Catalog Ø5.0 Ø5.0

4

Ø4.5 2

Ø5.0

4

Ø5.0

2

Ø5.0

Ø4.6

Ø4.5

Stainless Steel Housing

4 Ø4.5

4 Ø4.6 Ø4.2 Ø4.6

041CAN

Code

3

· The size of the new stainless steel housing has been reduced to provide stability and it is designed to strengthen the coherence with resin.

Ø4.5 3 2.6 Ø4.5

OT Cap(Orange) 3

Ø4.2 2.6 Ø4.6

3

Ø4.2

049PCNDR8

Code

· The OT-Cap is suitable for ball type overdenture material because it is made up of polyamide that has excellent elasticity and abrasion resistance. *Cap replacement is recommended after 12 month of use.

2.6

Ø4.6

3

Ø4.2

2.6 Ø4.2 2.6

Insertion Tool For Caps 085IAC

Code

· A tool that is used to insert the cap in the stainless housing Possible to use both tip in a normal and micro situation. · Packing Unit : Handle + Tip

C

Remover Tool For Caps

C

091EC

Code

C

C

C

· A tool that is used to remove the cap from the stainless housing Possible to use in both normal and micro situation with one tool.

Locator Length

Ø3.8 / 4.0 / 4.5 / 5.0

0.5

LOC 8656S

2

LOC 8657S

3

LOC 8658S

4

LOC 8659S

5

LOC 8660S

Male Retention Code

1.5 lbs

3 lbs

LOC 8529

LOC 8527

● Blue

● Pink

Locator Core Tool Code

32

LOC 8393

5 lbs LOC 8524

○ White


Conical Abutment

c

c

c

c

D D

Ø4.8

1

UCA 4801

2

UCA 4802

3

UCA 4803

L · Maintains screw and prosthetic aesthetics. · For fabrication of prosthetic on cylinder after abutment has been placed. L · Up to 48° path angle L · Uses Ø2.0 Conical Abutment Driver D (HD 2012A) L · Packing Contents : Abutment · Tightening torque : 30 ~ 35Ncm D L

c

D

Cuff

D

Healing Cap

D

Length

L

4.5

L

D D

L

D

L

D

Hex

Non-Hex D

Hex

Non-Hex D

Hex

D

Non-Hex Non-Hex

Hex

Hex

Non-Hex

HCN 40504 -

4.6 L

D

Ø5.0

· Protects the Conical Abutment and promotes patient healing. · Uses 1.2 Hex Driver · Packing Contents: Healing Cap D · Tightening Torque : 20Ncm D

Angle

Hex

Cuff Angle Angle Hex

Non-Hex

Cuff Angle Cuff Hex

Non-Hex

Cuff

Non-Hex D

Multiunit Abutment Hex

Cuff Angle

Cuff

Hex

Non-Hex Hex Non-Hex *Multiunit Abutment Holder : MAH 1425 Hex Non-Hex *Multiunit Abutment Holder : MAH 1425 *Multiunit Abutment Holder : MAH 1425 *Multiunit Abutment Holder : MAH 1425 *Multiunit Abutment Holder : MAH 1425

20ºNon-Hex Non-Hex Non Hex

Hex

D

L

UMA 482520H

UMA 482520N

-

-

3

UMA 483020H

UMA 483020N

UMA 483030H

UMA 483030N

4

UMA 484020H

UMA 484020N

UMA 484030H

UMA 484030N

UMA 485020H

L UMA 485020N

UMA 485030H

UMA 485030N

5 Screw

L

L

MAS 2006S

· Packing Contents: Abutment + Screw + LHolder D L · Tightening torque : 30 ~ 35Ncm L

D Non-Hex

Multiunit Screw HexDriverNon-Hex D

L

Non Hex

2.5

Hex

L

30º Hex

Non-Hex

L

D

D

Hex

D

D

D

D

Hex

Hex

Non-Hex D

Length 25

Hex

D

Non-Hex Non-Hex

Hex

Hex

Non-Hex

Ø1.4 MSD 1425

0.5 Slot 0.5 Slot

Pick-up Impression Coping L D

Cuff

D Hex D Hex D Hex Hex

Non-Hex D

Hex

Non-Hex Non-Hex Non-Hex Non-Hex

2.5

0.5 Slot 0.5 Slot L 0.5 Slot Hex

30º Non Hex

L

IPN 40508

L

IPN 40508N

L

· Create final impression of Conical Abutment on Impression Coping. D · For use with pick-up type custom trays. D · Packing Contents : Impression Coping + Guide Pin D D

D

L L L

L

L

33


0.5 Slot

UFⅡ Implant Product Catalog

L D

Hex

Non-Hex D

Transfer Impression Coping ICC 4805 / ICCS 1407

Code L

Gold Cylinder Ø2.0

Length 12

Hex Hex Hex Hex

Hex

Ø5.0 Non Hex

Screw

AGN 40504

AGN 40504N

SHN 1403

Order Code : PP 2022 · PP 2023

· Cylinder Melting Point: 1400 ~ 1500℃ (Depending on casting machine). · Uses 1.2 Hex Driver Drill · Packing Contents : Gold Cylinder + Cylinder Screw · Order Code : DSU 2708M DSU 2710M · Tightening Torque : 20Ncm DSU 2711M · DSU 2713M DSU 2708M

D D DD

Parallel Pin

Non-Hex Non-Hex Non-Hex Non-Hex

Initial Drill

DSU 27xxM

L LLL

Order Code : DHF 2015SM

Starter Drill Order Code : SD 1530M

Plastic Cylinder Length 13

D D DD Hex Hex Hex Hex

Hex

Ø5.0 Non Hex

Screw

APN 40514S

APN 40514SN

SHN 1403

· Cast in premium gold alloy after customization. · Less precise than the gold cylinder. · Uses 1.2 Hex Driver · Packing Contents : Plastic Cylinder + Cylinder Screw · Tightening Torque : 20Ncm

Non-Hex Non-Hex Non-Hex Non-Hex

Temporary Cylinder

AH 1425 MAH 1425 AH 1425 MAH 1425

L LLL

Length 11

D DD D

Case *BottomHex

Non-Hex Non-Hex Non-Hex Non-Hex

Hex Hex Hex

Hex

Ø5.4 Non Hex

Screw

TCN 40511

TCN 40511N

SHN 1403

· For fabricating temporary prosthetics on top of Conical Abutments. · Simple customization · Minimizes restriction · Uses 1.2 Hex Driver Fixture Driver · Packing Contents : Temporary Cylinder + Cylinder ScrewOrder Code : UNFDC 3006* · UNFDW 3006* · Tightening Torque : 20Ncm UNFDC 3012 · UNFDW 3012 UNFDC 3018 · UNFDW 3018

Torque Wrench

Order Code : DTW 0060 0.5 Slot 0.5 Slot Slot 0.5 0.5 Slot 8.5 / 10 / 11.5 / 13 / 15 / 18

L LLL Order Code : DPG 2050

Depth Gauge

D D DD

CylinderTap Screw Drill

1.2 Hex Screw Driver

Order Code : UNTD 3015 · UNTD 3315

Length

M1.4

3.0

SSN 1403

Abutment Analog L LLL

Length

Ø4.8

12

RCN 40412

· Provides anchor point for Conical Abutment. · Packing Contents : Analog

34

Order Code : MD 1230 · HD 1220A


UF Master Kit

Order Code : UF(M) 06

Parallel Pin

Order Code : PP 2022

PP 2023

Initial Drill Order Code : DSU 2008M

Drill

Order Code : DSU 2708M · DSU 3008M · DSU 3208M · DSU 3808M · DSU 4308M

DSU 2710M · DSU 3010M · DSU 3210M · DSU 3810M · DSU 4310M DSU 2711M · DSU 3011M · DSU 3211M · DSU 3811M · DSU 4311M DSU 2713M · DSU 3013M · DSU 3213M · DSU 3813M · DSU 4313M

DSU 2010M DSU 2011M DSU 2013M

Starter Drill

Profile Drill

Order Code : UPD 3805M

UPD 4005M UPD 4505M UPD 5005M

Order Code : SD 1530M

Lindemann Drill Order Code : RMH 2014S

Tap Drill

Order Code : UNTD 3015

UNTD 3315 · UF(II) Regular is available (optional)

Drill Extension Order Code : DE 3507M

Mount Driver

Order Code : MHDC 2520

MHDR 2513A

Fixture Driver

Abutment Removing Driver

for UF(II) Regular/Wide Order Code : FDC 3506 · FDW 3512A

Fixture Driver

Order Code : HARD 20315A

for UF(II) Narrow Order Code : UNFDC 3012

FDC 3512 · FDW 3518A

UNFDC 3018

Order Code : UNFDW 3012

UNFDW 3018

Solid Abutment Driver

Order Code : HDS 4506A · HDS 5506A · HDS 6506A

HDS 4512A · HDS 5512A · HDS 6512A

Ball Abutment Driver

Screw Driver Order Code : MD 1230

HD 1215A

Order Code : HD 2412A

*Bottom Case

Depth Gauge Order Code : DPG 2050 8.5 / 10 / 11.5 / 13 / 15 / 18

Torque Wrench Order Code : DTW 0060

Open Wrench Order Code : OW 004

8.5 10 11.5 13 15 18

35


UFⅡ Implant Product Catalog

Order Code : UF(M) 07

Ø2.0

UF Surgical Kit

Parallel Pin

Order Code : PP 2022

PP 2023

Drill

Initial Drill

Order Code : DHF 2015SM

Starter Drill

Profile Drill

Order Code : DSU 2708M · DSU 3008M · DSU 3208M · DSU 3808M · DSU 4308M

ST 2008F · ST 2010F ST 2011F · ST 2013F

Order Code : UPD 3805M

DSU 2710M · DSU 3010M · DSU 3210M · DSU 3810M · DSU 4310M DSU 2711M · DSU 3011M · DSU 3211M · DSU 3811M · DSU 4311M DSU 2713M · DSU 3013M · DSU 3213M · DSU 3813M · DSU 4313M

UPD 4005M UPD 4505M UPD 5005M

Order Code : SD 1530M

Lindemann Drill Order Code : RMH 2014S

Drill Extension Order Code : DE 3507M

Tap Drill

Order Code : UNTD 3015 · UNTD 3315

· UF(II) Regular is available(optional)

Fixture Driver

Screw Driver

Fixture Driver

Order Code : MD 1230 · HD 1215A

for UF(II) Narrow Order Code : UNFDC 3012

for UF(II) Regular/Wide Order Code : FDC 3506 · FDC 3512

UNFDC 3018

FDW 3512A · FDW 3518A

Order Code : UNFDW 3012

UNFDW 3018

*Bottom Case

Depth Gauge Order Code : DPG 2050 8.5 / 10 / 11.5 / 13 / 15 / 18

Torque Wrench Order Code : DTW 0060

Open Wrench Order Code : OW 004

8.5 10 11.5 13 15 18

36


UF(II) Wide Surgical Kit

Order Code : UF 09

Final Drill

Trephine Drill

Order Code : TRD 4739

TRD 5244 TRD 5749

Order Code : DSU 5007 · DSU 5507 · DSU 6007

DSU 5008 · DSU 5508 · DSU 6008 DSU 5010 · DSU 5510 · DSU 6010 DSU 5011 · DSU 5511 · DSU 6011

Fixture Driver

Order Code : FDC 3506 · FDW 3506A

FDC 3512 · FDW 3512A

Drill

15 · UNTD 3315

ure Driver

(II) Regular/Wide Code : FDC 3506 · FDC 3512

Tap Drill

Order Code : UT(II) 6006 · UT(II) 6506 · UT(II) 7006

FDW 3512A · FDW 3518A

Profile Drill

Order Code : UPD 6010 · UPD 6510 · UPD 7010

0

37


UFⅡ Implant Product Catalog

Regular / Wide Starter Drill

L1 L1 D D L2 L2

D D

8.5 7

D D

D1 D1

D

Ø2.0 Ø2.0

D D

L2 L2

L2 L1 L2

L2

L2 L2

L2 L2

L1 L1

L2 D

D L2

L1 L1 L1

D2 D2

D1 D1

D1

L2 D1

L2

D1 D1 D2 D2

Ø2.0

0.5

D Ø2.0 L1 L2

Ø2.0

D1 D1 D1 D1 D1

D2 D1 D2 D D

D2 D2 D2

7

L2

0.5

L2

0.5 L1

7

10 137

D2

DSU 2010M DSU 2011M

L2

Ø2.0 / Ø2.7 PP 2015

22 / 10

PP 2022

23 / 16

PP 2023

L2 L2

D D

D

L2

L2

Ø0.6 / Ø2.0

Ø0.75 / Ø2.0L2

23 / 15

PP 1223

PP 1523

L1 / L2

Ø2.0 / Ø2.7

31 / 17

PS 3512

D

Ra Rat

L

L1

L1

L2 L2 L Machine L Machine

Rat

L L L

Straight Drill

L2

L2 L1

L1 / L2

Ø2.7

33 / 15.63

SDS 2715BM

L1 L L

L L

Ø2.6

Ø2.9

Ø3.1

L

Ø3.7

Ø4.2

L L DSU 2708M DSU 3008M DSU 3208M DSU 3808M DSU 4308M LDSU 4808M

33 / 10

DSU 2710M DSU 3010M DSU 3210M DSU 3810M DSU 4310M DSU 4810M

33 / 12

DSU 2711M DSU 3011M DSU 3211M DSU 3811M DSU 4311M DSU 4811M

33 / 13

L1 4313M DSU 4813M DSU 2713M DSU 3013M DSU 3213M DSU 3813M DSU

● Purple ● Blue ● Yellow

D1 D1

L

Ø4.8

33 / 9

Color

L1

L L

L L

L

L L

L1

D2 Red ● D2

● Gray ● Green ○ White

Profile Drill

L1 L1 D L1 L2 L1

L1

D1 D1

L1 / L2

Ø3.8

Ø4.0 D2

30 / 16

UPD 3805M

Color

● Blue

UPD 4005M D2

D2

D1 ● Red

D1

D D

Ø4.5 L2 UPD 4505M L2 L1

D1 ● Gray D2 L2

D D

L2 L1 L2 Machine Machine L2 Machine

Machine

D2

38

L

Machine Machine

L1

L1 / L2

L1 / L2

L2 L1

R

D2

L1

L2

L1

8.5

L1D L1 L1 L2 0.5

Machine L L2 Machine L2 Machine L Machine Machine L1 L1

10 13

15 / 8

L

L1 L1 L L Machine

DSU 2013M

L1 / L2

L

Machine Machine

Pilot Drill

L1 L1 D L1

7

8.5 L1 L1

L

Machine

L2 L2

D D

D D

DSU 2008M

Drill 7

L2 L2 D L2

8.5

L L Machine Machine LL L Machine Machine Machine

L L2

L2 L2

L1 L1

L2 L2

10 13

D2

R

L2D2

L2 D

8.5

D D 0.5 8.5 D 0.5D D D 0.5

Ø2.0

L2

L1

7 8.5 8.5

7

D2 D2 L2 L1 L2 L2 D2 L2 L1 L1 L1 L2 D2 D1 D1 L1 L2 L2 L2 L1 L2 L1 L2 L1 L2 L1 L1 L1 L2 D1 D1

D

L2 7 L2 7

Length

L1

L2

D D 0.5 0.5

DHF 2015SM

Parallel Pin

D2 L1

L1 L1 D2 D1 L2 L2 L2

D

8.5 8.5

L1

D2 D2

D2

7 7

Ø2.0

L L Machine Machine

34.5 / 17.5

8.5 11.5 15 10 7 10 13 7 10 13 11.5 8.5 11.5 0.515 8.5 11.5 15 0.5 8.5 11.5 15 7 10 13 13

L2 L1

SD 1530M

Ø2.0

8.5 11.5 15 8.5 11.5 15

0.5

30 / 15

L1 / L2

L1 L1L1 L1

D1 D1

D D D2 D2

0.5 L2 0.5

L2

Ø2.0

L1 L2 L1 L2

D1

7 10 13 7 L1 10 13

D

Ø2.0

Ø1.5

Initial Drill

8.5 11.5 15 8.5 11.5 15

L1

D L2 L1 L1

0.5 0.5

L1

L1 D L1

D

D1 D1

L1 L1

L1 / L2

L2 D2

L

L1 L1

Ø5.0

L1

UPD 5005M D1

L1

● Green

L D D

L1

D L2

L2

D


L1

D L2 L1

L1

D1 D2 L2

Tap Drill Fixture / Drill D

Ø3.0

Ø3.3

Ø3.8

Ø4.0

Ø4.5

Ø5.0

Code

UNTD 3015 UNTD 3315 UT(ll) 3815 UT(ll) 4015 UT(ll) 4515 UT(ll) 5015

Color

●Purple ●Yellow

●Blue

●Red

●Gray

●Green

· Option) Ø3.8/4.0/4.5/5.0 Availble

Fixture Driver Length

L Machine L

L Machine Machine L L

L Ratchet Ratchet L L

Machine Machine

Ratchet Ratchet

L

L

Machine Machine L L Machine Machine

Machine L1

FDW 3512A

18

FDC 3518

FDW 3518A

Ratchet

6

MHDC 2520

MHDR 2513A

11

MHDC 2525

MHDR 2518A

L Screw Driver Ratchet L

L

1.2 Hex Ratchet

MD 1219

5

HD 1205A

L

MD 1222

10

HD 1210A

30 / 16

Ratchet

MD 1230

15

HD 1215A

20

HD 1220A

L Ratchet

Solid Abutment Driver

L

Length

Ø4.5

Ø5.5

Ø6.5

6

HDS 4506A

HDS 5506A

HDS 6506A

12

HDS 4512A

HDS 5512A

HDS 6512A

Ratchet L2 Machine

L L

L1 / L2

22 / 8

19 / 5

L1

L

1.2 Hex Machine

Ratchet L1 / L2

L

Machine

L Ratchet

L

L2 Machine

L

2.5 Hex Machine

L

L L Ratchet L Ratchet L1 L L RatchetRatchet L Ratchet Machine

L2 L2 Machine LMachine L2 Machine L2 Machine Machine

FDW 3506A

FDC 3512

L Ratchet Ratchet

Machine L2 Machine

L1 L1

FDC 3506

Length

Ratchet Ratchet L L Ratchet L1 L Ratchet

L1

Ratchet

Mount Driver L

L L Machine Machine L

Machine

12

6

L

L

Ratchet

L Ratchet

L1

Ball Abutment Driver

L

L2

Length L2 Machine

L Ratchet

L

L

L

L

L

12

D DD

L

L2

L

L2HD

2406A

L2 L2HD

2412A

L L

L

Octa Abutment Driver

L L

L L

D

6 D

L

2.4 Hex L

L1

L

L

L1 L2

L1

3.0L1Octa L

Length 6

L1

D

HD 3006A

L1

HD 3012A

12

L

L2

Conical Abutment Driver 15 Length L

L 15

L1

D1

D2

D2 D2D2

D1

L1

L1

L

L2

LL2

L2

L

L2 L2

12

HD 2012A

D1

D

L2

D

LengthL

D

6

D L1 DD

D2

Removing Driver

L L L

L1 L1

D1D1

L

L

2.0 Int. Hex

2.7 Int. Hex HD 2712A

L1

1515

D2 D1

15

D

D

D

L

12

DD Hex A Hex A

Hex B Hex B

D HexHex AA

HexHex B B

L2 D

M 2.0

15

HARD 20315A L1

Hex A

15 D

HexHARD B

20320A

39


L Machine Ratchet

e

Ratchet

Medium Bone (D

L

0.5mm

UFⅡ Implant Product Catalog

Soft Bone

L

Medium Bone (D2, D3)

L Ratchet

L

0.5mm L2

Hard Bone (D1, D2)

L

Soft Bone

D

Positioning Guide L2

L

L

L1

Length

L D

Ø2.0

7

L1

L

Medium Bone (D2

PG 0060

L2 L

L D

L2 L

Drill Extension

L

L

L1

L1 / L2

Code DE 3507M

26 / 12

L1

15 L2 15

D1D

L1

D2

L L

15

L2

15

Ø1.4 / Ø2.0

30 / 14

RMH 2014S

D

Hex A

D

Soft Bone Hex A

Length D

Hex B

0.5mm

D

Soft Bone

15 Hex A

D L

D

Hex B Angled Path Pin

Medium Bone (D2, D3)

D

Hex A

0.5mm

Ø4.5

Angled

Hex B

Medium Bone (D

Ø3.5 DPP 3512

12

Hex B

0.5mm

D

Path Pin

L

L2

L1 / L2 L1

D L1

D1

ex A

L Lindemann Drill

L

Hex A

Hex B (D1, D2) Hard Bone

15˚

MHDC 2520

MHDR 2513A

Color

● Blue

● Green

Hex B

Only for UF(II) Wide Trephine Drill Diameter

Ø4.7

Ø5.2

Ø5.7

Code

TRD 4739

TRD 5244

TRD 5749

L

Ø4.9

Ø5.4

Ø5.9

Final Drill 7

DSU 5007

DSU 5507

DSU 6007

8.5

DSU 5008

DSU 5508

DSU 6008

10

DSU 5010

DSU 5510

DSU 6010

11.5

DSU 5011

DSU 5511

DSU 6011

Diameter

Ø5.4

Ø5.9

Ø6.4

Code

UT(II) 6006

UT(II) 6506

UT(II) 7006

Diameter

Ø5.4

Ø5.9

Ø6.4

Code

UPD 6010

UPD 6510

UPD 7010

Tap Drill

Profile Drill

40

Soft Bone

Medium Bone (D2


Regular Fixture Surgical Protocol

I Bone Level Application Starter Drill Initial Drill 1,200rpm

1,000rpm

Drill 800rpm

Profile Drill Tap Drill 300rpm

50rpm

UF(ll) Fixture 20rpm

Drill

Using 8.5mm Drill with laser marking to place 7mm implant.

7 77

7

8.5 8.5 8.5 8.5 0.5

8.5

7

0.5 0.5 0.5 0.5

0.5mm 0.5mm 0.5mm 0.5mm 0.5mm

Soft Bone Soft Bone SoftSoft Bone Bone Soft Bone Medium Bone (D2, D3) Medium Bone (D2, D3) Medium Bone (D2,(D2, D3)D3) Medium Bone Medium Bone (D2, D3)Hard Bone (D1, D2) Hard Bone (D1, D2) HardHard Bone (D1,(D1, D2)D2) Bone Hard Bone (D1, D2)

Profile Drill Drilling depth can be effect initial stability. Upper Lower Lower Lower Lower

Upper Upper Upper Upper

Lower

I Bone Level 1mm Sub Application Starter Drill Initial Drill 1,200rpm

1,000rpm

Drill 800rpm

Profile Drill Tap Drill 300rpm

50rpm

UF(ll) Fixture 20rpm

Lower Used to reduce applicable torque on D2, D3 Bone. Upper Used to reduce applicable torque on D1, D2 Bone.

1mm 1mm 1mm1mm 1mm

Tap Drill 1mm

0.5mm 0.5mm 0.5mm 0.5mm

1mm 1mm1mm 1mm 7.5mm

0.5mm

Soft Bone Soft Bone SoftSoft Bone Bone Soft Bone Medium Bone (D2, D3) Medium Bone (D2, D3) Medium Bone (D2,(D2, D3)D3) Medium Bone Medium Bone (D2, D3)Hard Bone (D1, D2) Hard Bone (D1, D2) HardHard Bone (D1,(D1, D2)D2) Bone Hard Bone (D1, D2)

7.5mm 7.5mm 7.5mm 7.5mm

41


Soft Bone Medium Bone (D2, D3)

UFâ…Ą Implant Product Catalog

rd Bone (D1, D2)

Hard Bone (D1, D2)

Wide Fixture Surgical Protocol

0.5mm

Soft Bone Fixture Length 6.5mm

Medium Bone (D2, D3)

Straight Drill

Drill

800rpm

300rpm

Fixture Length 6.5mm

0.5mm

Soft Bone Medium Bone (D2, D3) Hard Bone (D1, D2)

Fixture Length 7mm

42

Tap Drill UF(ll) Wide Fixture

Hard Bone (D1, D2) 50rpm

20rpm


I Bone Level Application Fixture Length over 11.5mm Straight Drill

Drill

800rpm

300rpm

Tap Drill UF(ll) Wide Fixture 50rpm

20rpm

0.5mm

0.5mm

Soft Bone

Soft Bone

Medium Bon

Medium Bone (D2, D3) Hard Bone (D1, D2)

I Bone Level 1mm Sub Application Fixture Length over 11.5mm Straight Drill

Drill

800rpm

300rpm

Tap Drill UF(ll) Wide Fixture 50rpm

20rpm

路 Use Straight Drill without stopper

1mm

0.5mm

Soft Bone Medium Bone (D2, D3) Hard Bone (D1, D2)

43


UFⅡ Implant Product Catalog

General principles of surgical tool management 1 / Because all surgical tools are provided in a non-sterile condition, they must be cleansed and sterilized before use. Caution Wrong cleansing and sterilizing process causes corrosion and damage to the tools and if used directly, it may be the cause of 2nd infection.

2 / The recommended number of use of a drill is 20~30 times based on the bone status, and it must be replaced if the blade has been damaged or transformed. Caution

1 Sterilization 1 / Must only use antiseptic solution that is FDA and CE approved, and you must follow the manufacturer’s directions 2 / When cleansing metal instruments, corrosion free antiseptic solution and cleansing product use is recommended. 3 / For safety, one must always wear personal protection gear such as gloves, glasses, and masks. 4 / The user has an obligation to be responsible for the sterilization and management of the instrument.

If damaged drill is used, Heat Necrosis may occur

3 / When managing the surgical tool, one must wear a mask and a glove to prevent infection.

Before sterilization 1 To prevent contaminants such as blood, tissue cell or bone residue from attaching to the surface of the instruments, the instruments must be immersed in an antiseptic solution right after use. /

2/ When using antiseptic solution, to prevent corrosion or bronzing, one must follow directions given by the manufacturer of the concentration of the antiseptic and the duration of the instrument immersion in the antiseptic.

5 / Restriction and limitation of the instrument reuse: · With repetition of cleansing, the life expectancy of all instruments will decrease. If the instruments show corrosion, transformation or discoloring of the marking area, it means that they have exceeded the safety criteria that is required for use. ·Product with a disposable mark cannot be reused. ·Tungsten carbide burs, plastic composition and NiTi instruments can be damaged with hydrogen peroxide, and aluminum material instruments can be damaged by caustic soda solution. ·Acid solution (pH < 6) and alkaline solution (pH > 8) must not be used.

Check Concentration : completely liquefy the concentrate before placing the instruments in the antiseptic solution. Immersion Duration : The instruments must not be immersed more than a day

3/ The instruments must be fully immersed in the antiseptic solution. 4/ For a decrease in sterilizing power and to prevent corrosion, the antiseptic solution must be replaced every day.

Before rinse To prevent protein from clotting in 45 degrees temperature Celsius, the instruments must be rinsed in running cold water. Caution

Sterilization

2 Cleanse / Dry

However, do not cleanse the different materials together. Also, when immersing the instruments in the ultrasonic cleaner, make sure that the instruments do not touch each other.

Surgical Tool Mainteance Process

3 / Make sure that debris is not seen with the naked eye.

Storage Pack

Pasteurization

Do not use a wire brush or stainless material brush, and do not put too much pressure.

2 / Immerse the products in the antiseptic solution of their characteristics and clean with an ultrasonic cleaner.

Surgery

Cleanse

44

After use, if the contaminants such as residual bone or blood stain are not completely removed, it may lead to corrosion; therefore all separable instruments must all be disassembled before the cleansing process.

1 / Contaminants must be completely removed using a soft brush.

Cleanse the instruments right after preliminary rinse

Dry

Caution

· Products that are fractured or transformed must be discarded. · One should follow the recommendations for the level of concentration or the length of time provided by the manufacturer. · The antiseptic solution must not include aldehyde, di- or tri-ethanolamines component to control the corrosion.


4 / After cleaning, the products must be rinsed with distilled water or deionized water for at least a minute. If the antiseptic solution contains corrosion inhibitor, rinsing before placing in the sterilizer is recommended.

5 / To prevent corrosion or water stain on the instruments, completely dry with a dryer or filtered compressed air 6 / To prevent corrosion, decrease in sterilizing power, and contamination, antiseptic must be supplemented every day.

Caution If the instruments are not properly rinsed, residue is left behind, or is not properly dried, the sterilization process might discolor or corrode the instruments, and therefore the whole process must be gone through again.

4 Pasteurization 1 / Pasteurization process must follow the sterilizer equipment manufacturer. ※ 4~ 18 minutes in 134’C for autoclave sterilization. 2/ Instruments and plastic components must be sterilized based on their packaging label. ·Sterilizer must coincide with the requirements of EN 13060 and EN285. ·Sterilization process must regard the ISO 11607. ·One must follow the sterilization process and maintenance process of the sterilizer provided by the manufacturer. ·Efficiency management (Proper packaging, no humidity, change in color of the sterilization dashboard)

Caution · The products must not touch the inner part of the sterilization equipment, and the sterilization degree must be lower than 150℃ · The products that were not properly cleansed or dried may generate corrosion. If they were not cleansed, not properly dried or corroded, separate them from the rest or remove the faults. (Do not sterilize the corroded instruments with the noncorroded products together) · For sterilization, use only salt-free water or distilled water for the solution. (Do not use tap water) · Check if the instruments are fully dried, and do not leave them in a place with high moisture.

Caution Corrosion may start if debris such as blood stain or bone residue is not completely removed. They must be cleansed right after use and the debris must be completely removed when cleaning.

Check Check on the instruments for faults (fracture, transformation, or corrosion). If necessary, assemble the instruments. Contaminated instruments must be cleansed or disinfected. Transformations that may affect the safety, performance or tolerance of the instruments; in other words; bent, damaged (fractured, corroded), or faulty products (discoloration of marking area, Loss) must be destroyed.

5 Storage Instruments must be stored in a sterilized container in a dry and clean environment. If the packaging is opened or damaged, we cannot guarantee the instruments’ sterilization status.

3 Packaging 1 / Check on the dry status of the instruments and pack in the sterilized wrapping paper. 2 / On the sterilized wrapping paper, attach a direction tape to check the date of sterilization. Check on the expiration date on the sterilized wrapping paper. Wrapping paper must be able to withstand up to 141 degrees that coincides with the EN ISO 11607.

45


Digital Implant No.1 Date of publication I April 2015 Editing I DIO Implant Marketing team Publisher I DIO Implant Headquarters



DIO Implant 66, Centum seo-ro, Haeundae-gu, Busan 612-020, Korea

Tel +82 51 745 7777

Fax +82 51 745 7778

www.dioimplant.com

UFS01E Ver.01_201504


Turn static files into dynamic content formats.