Surgical instruments Catalogue

Page 1

Sinus-T Surgical Instruments Sinus-T

Osteotome Technique by TR Sinus System “TR Sinus System” contains trephine drills and round drills, will provide easy & safe sinus membrane lifting.

Order Code: SNT 01

Surgical Instruments

To overcome the short of bone length on maxillary molar area in case of sinus membrane lifting, osteotome technique is useful to obtain sufficient bone for placing implant.

Ø3.0 / Ø3.5 / Ø4.0

Ø3.0 / Ø3.5 / Ø4.0

Ø2.0 / Ø2.5 / Ø3.0

8

7

6 5

Ø5.0

4 3

15

15 O-Ring

29

29

ST 4006

ST 4007

ST 4008

ST 4009 ST 4010

Drill Stopper

Ratchet Adapter

Depth Gauge

RA 8011

Trephine Drill

Round Drill

STD 3020L STD 3525L STD 4030L

SRD 3008L SRD 3508L SRD 4008L

Ø2.5

72

SDG 2515

ST 4011


Sinus Protocol Precise X-Ray reading is very important to approach closely under the sinus floor with trephine drill.

0.5~1mm

7mm

15~20rpm

1 Drilling

2 Push

3 Drilling

4 Insertion

1,000~1,500rpm

1 Drilling (Trephine Drill)

Choose correct length of stopper and put it on the trephine drill and then drill 0.5~1mm under the sinus floor. (Drill Speed : 1,000 ~ 1,500 RPM) Putting stopper on the trephine drill reduce the risk of perforation of sinus floor accidentally during the surgery.

2 Push (Osteotome)

After malleting at correct position of osteotome, do microfracture safely on sinus floor. Mallet 2 or 3 times to obtain a microfracture on sinus floor. If the several malletings do not work for the microfracture, do drilling again with trephine drill toward sinus floor. (Drill Speed : 15 ~ 20 RPM)

3 Drilling (Round Drill)

Enter the osteotomy site with round drill, thereby lift the sinus membrane slowly. (Drill Speed : 15 ~ 20 RPM) Round drill minimizes the risk of perforation of sinus membrane with rounded shape.

4 Insertion (Fixture) After checking the lift of the sinus membrane, place the fixture.

73

Surgical Instruments

15~20rpm


Dr.SOS Surgical Instruments Dr.SOS

Immediate Action For Emergency The Kit for the easy removal of Broken Abutment Screw Regeneration of damaged internal threads in the fixture

External Guide

Order Code: DRS 00

Internal Guide

Remove Bar

0.3 Slot Driver Reverse Cutting Drill

Surgical Instruments

Screw Tapping

0.3 Slot Driver When Torx Abutment Screw Head was damaged, you can use 0.3 Slot Driver instead of 1.7 Torx Driver.

Machine MD 0322

Ratchet HD 0315A

1.7 Torx Abutment Screw

74


External Guide (External Connection) It is connected to fixture and guides through Remove Bar to enter and support broken abutment screw.

Hex

2.4 Hex Branemark Connection

2.7 Hex Branemark Connection

3.4 Hex Branemark Connection

EXT 24S

EXT 27S

EXT 34S

EXT 24L

EXT 27L

EXT34L

Short

Long

External Hex

Surgical Instruments

Internal Guide (Internal Taper Connection) It is connected to fixture and guides through Remove Bar to enter and support broken abutment screw. Mores Taper

Morse Taper 6째

Morse Taper 8째

Morse Taper 11째

INT 6S Torx

INT 8S Torx

INT 11S Hex

Morse Taper 5.7째

Torx

*HEX Type

INT 6L

INT 8L

INT 11L

INT 5.7S

Non-Torx

*Option: ITI Guide

75

*Narrow Fix


Reverse Cutting Drill

Remove Bar

Connect the Reverse Cutting Drill to low speed handpiece, with 1,000~2,000 RPM in reverse rotation. Then, repeat drilling up and down to grind and change the top of the broken screw.

Under 20 RPM in reverse rotation

*CAUTION): Be careful not to break it with overheating.

RBEX 24S

RBEX 24L

IRBS

IRBL

RCD 36

Ø1.25 External 2.4 Hex

External 2.7/3.4 Hex Internal 6°, 8°, 11°

Surgical Instruments

Screw Tapping When internal threads in the fixture were damaged, use Screw Tapping to regenerate fixture internal threads.

SGT 1620A

SGT1820A

SGT2020A

SGT2520A

Screw External Fixture

Ø1.6

Ø1.8

Narrow

Non Submerged Internal Fixture Submerged Internal Fixture

Ø2.0

Ø2.5

Regular T-Wide

Wide

Internal Fixture (PSI, IFI) SM Narrow

SM Regular SM Wide Extra Wide

Handle

Torque Wrench

RBH 10

DTW 0060

76


Immediate Action For Emergency, Dr. SOS The Kit for the easy removal of Broken Abutment Screw Regeneration of dameged internal threads in the fixture

Ready After cleaning thoroughly broken screw area, repeat inserting oral-use oil to let the broken screw out.

Guide Fixing Locate a proper guide from the "Dr.SOS Kit" onto a fixture inside mouth and support it securely to make it vertical. *You can use ratchet to support the guide when it's hard to support the guide by hand.

A) Remove Bar Connect Remove Bar to the Handle, reverse it by hand to remove the Broken Abutment Screw, and be careful not to drop off the product into the mouth. *Confirm the level of line on the Remove Bar.

B) Remove Bar + Handpiece After connecting the Remove Bar into low speed handpiece, it is also possible to remove it with reverse rotation of low RPM.

Surgical Instruments

*less than 25 RPM. *Remove Bar and drill extension connection enables a longer use.

Explore Use explore to completely remove it after reaching certain height.

Screw Tapping When fixture internal threads were damaged, use Screw Tapping to regenerate fixture internal threads and connect Abutment.

Tip)

TIP) When pulling, hand will feel it touches. If no touch on hands, lean guide and bur left and right until getting feel. 77


Bone Expander Set Surgical Instruments Bone Expander

Order Code: BEP(M) 00

Osteotomes have been utilized in a variety of techniques designed to prepare implant sites in maxilla, to elevate the floor of the maxillary sinus and to expand the atrophic edentulous ridge. Despite its effectiveness, the surgical mallet is not well tolerated by patients. Using a drill to prepare implant sites in maxilla and mandibular also have a risk of maxillary perforation and penetration into the nerve 2 3 0 1 mandibularis. 7 9 As safe alternative and complementary instruments to the 4 5 6 8 10 osteotomes and drills, 11 Bone Expander can be used for preparation of implant sites, atraumatic ridge expansion and condensing of bone.

Description

Code

0

1.2mm Initial Drill

MSD 1218M

1

1.0/1.6mm Bone Expander

2

Apical/Neck(Ă˜)

Length

1.2

16

BEP 1716

1.0 / 1.6

17

1.3/2.3mm Bone Expander

BEP 1723

1.3 / 2.3

17

3

1.7/3.1mm Bone Expander

BEP 1731

1.7 / 3.1

17

4

2.4/3.7mm Bone Expander

BEP 1737

2.4 / 3.7

17

5

3.0/4.4mm Bone Expander

BEP 1744

3.0 / 4.4

17

6

3.5/5.1mm Bone Expander

BEP 1751

3.5 / 5.1

17

7

Driver(short)

MHDC 2520

Color Code

For Contra Angle

8

Driver(long)

MHDC 2525

9

Driver(short)

MHDR 2513

For Ratchet Wrench

10 11

Driver(long)

Torque Wrench

Open Wrench

MHDR 2518

DTW 0060

OW 002

78

(mm)


0

1

2

Pic 1

Pic 2

Pic 3

3

IFI35xx

Pic 4

4

IFI40xx SFN38xx

5

Pic 5

IFI48xx IFI65xx SFR45xx

Pic 6

6

IFI55xx IFI65xx SFW53xx

Pic 7

*Option: MSD 2016(Pic 3->)

Protocol DIO Implant Bone Expander hardens Bone density to erase difficulties caused from Osseointegration of soft or Poor Bone. (This procedure shows the method of Implantation of SFW 5312) Pic 1

In order to give depth and direction to desired surgical area, 1.2mm drill is used. (800 rpmn 1200rpm is the capable engine speed)

Pic 2

To expand the implantation site, 1.6mm Bone Expander (Color Code: Yellow) is used (Check Laser Marking) *Connect the Bone Expander with Adapter. Then finish with Ratchet Wrench.

Pic 3

Use 2.3 Bone Expander (Color Code: Yellow) to expand the desired surgical area. (Check Laser Marking)

Pic 4

Use 3.1mm Bone Expander (Color Code: Yellow) to expand the desired surgical area. (Check Laser Marking)

Pic 5

Use 3.7mm Bone Expander (Color Code: Red) to expand the desired surgical area. (Check Laser Marking)

Pic 6

Use 4.4mm Bone Expander (Color Code: Green) to expand the desired surgical area. (Check Laser Marking)

Pic 7

Continue by using 5.1mm Bone Expander to expand the desired surgical area. (Check Laser Marking) Hardening the Bone has a risk of Ischemia which makes the Doctor to check whether sufficient bleeding is occurring. Give Scrape to the desired surgical area to increase bleeding - Bleeding help Osseo Integration. Implant SFW 5312 to the expanded hole by Bone Expander

79


Sinus Lift Kit Surgical Instruments Sinus Lift Kit Custom designed kit comprised of 6 tools used in sinus procedures

Code

Surgical Instruments

Sinus Elevator & Membrane Lift Tips

80

Order Code: SLK 01

Description

DSNK 01

Membrane Detach Elevator

DSNK 02

Membrane Elevator

DSNK 03

Membrane Elevator

DSNK 04

Bone Graft Packer

DSNK 05

Membrane Elevator


Osteotome Kit Surgical Instruments Osteotome Kit

Diameter(L)

0

Order Code: OST 01

Image

Code

OSE 2228

Ø2.8

Application

Sinus Elevation

Ø2.2

1

OSL 2028

Ø2.8

SM/ IFI/ FTN Initial Drill

Ø2.0

2

OSL 2130

Ø3.3

OSL 2133

Ø3.9

OSL 3039

SFR 45xx/ IFI 40xxM Compaction

Ø4.6

OSL 3546

SFW 53xx/ IFI 48xxM/ FTN 50xxB Compaction

Ø2.1

3 Ø2.1

4

FTN 33xxB

Ø3.0

Compaction

SFN 38xx/ IFI 35xxPM Compaction

Ø3.0

5 Ø3.5

81


Bone Planer Set Bone Planers are used to flatten the uneven bone during osteotomy reparation

Size & Code Narrow

Regular

Wide

Ă˜5.65

Ă˜5.9

30 10

5.5

Ă˜4.95 BP 5010

BP 5710

BP 5910

Protocol

1 Guide Drilling Drill through the cortical bone at the selected site for the implant placement.

2 Initial Drilling Select an appropriate drill stopper according to the desired depth of implant placement.

*Handpiece speed is recommended to be in a range between 400~600 rpm.

82

3 Bone Planing Insert its guide part into a drilled osteotomy site and remove the uneven bone.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.