Dr Paul Moore BDS ISCD Certified International Trainer for Computerised Dentistry GATE CLINIC DOCK ROAD, GALWAY, IRELAND Contact : tel: 00353 91 547592 email: drpmoore@mac.com web: www.gateclinic.com 1

Saturday 13 April 13


The Diagnostic Capabilities of Volume Cat Scan Images. Saturday 13 April 13


Introduction the Range of the Diagnostic Applications Prescription and Report Orthodontics Wisdom teeth Endodontics Pathology Trauma TMJ Airway / Sinus Studies Saturday 13 April 13

Dental Implants Initial Assessment Treatment Planning Maximising Prognosis Radiographic / Surgical Stents Implant Planning Software Options


Introduction Visualisation facilitates treatment and understanding. Understanding facilitates rational clinical decisions, patient understanding, acceptance.and informed consent. With the advantage of relatively low radiation compared to conventional cat scans ( from 6 - 35 times less radiation than full scale hospital cat scans). Distortion free images, allowing real measurements in three dimensions. No superimposition of structures. Allows investigate the related hard tissues, airway spaces and their relationship to vital structures such as the inferior nerve bundle in the mandible ( lower jaw) Documentation, legal records, communication with colleagues and patients Saturday 13 April 13


Prescription and Report

“3D Scan” Request Form.

Scanning options

All requests for a Cat Scan must be accompanied by a specific signed prescription including the purpose the scan is required.

A combination of voxel size and height of scan Voxel size

Scan Time

Scan height

Scan required: Mandible only

• 0.4 voxel

3cm height

10 seconds Maxilla only

• 0.3 voxel

• •

6 cm height 8 cm height

• •

6 cm

6 cm

20 seconds 40 seconds

Mandible and Maxilla 8 cm

• 0.25 voxel •

• 0.2 voxel

13 cm height 22cm height

Full

13 mm

Stent to be worn Nobelguide double scan (see 3)

Saturday 13 April 13

20 seconds

0.4 Voxels

10 seconds

0.3 Voxels

40 seconds

0.2 Voxels

20 seconds

0.4 Voxels

10 seconds

0.3 Voxels

40 seconds

0.2 Voxels

20 seconds

0.4 Voxels

10 seconds

0.3 Voxels

40 seconds

0.2 Voxels

20 seconds

0.4 Voxels

10 seconds

0.3 Voxels

40 seconds

0.2 Voxels

YES


6cm 20Sec 0.4Voxel • Approximate Dose = 32uSv • Dose in multiples of OPG = 2 For comparison,the I-CAT protocol illustrations, a 6cm mandible scan would give approx 32uSv Emotion 6 Hospital scanner for a 6cm height scan on the mandible this would give approx 228uSv.

Saturday 13 April 13


I Cat Vision • Allows viewing of Dicom 3 data • Compatible with windows computers • No charge for single disc • ID canal • Multiple measurements no distortion

Saturday 13 April 13

OPG adjustable

TMJ

3 Dimensional

Coronal

Axial

Sagittal

Printable

“JPG” able

Exportable


Saturday 13 April 13


Orthodontics

Saturday 13 April 13

.


Orthodontics

Saturday 13 April 13

.


Palatally impacted canine,

Orthodontics

. Saturday 13 April 13


Orthodontics

Odontome Assessment

. Saturday 13 April 13


Orthodontics

Saturday 13 April 13

Odontome Assessment

.


Orthodontics

Unerupted Canines

. Saturday 13 April 13


Wisdom Teeth

. Saturday 13 April 13


Endodontics

. Saturday 13 April 13


Endodontics

. Saturday 13 April 13


Endodontics

. Saturday 13 April 13


Pathology

. Saturday 13 April 13


Trauma

. Saturday 13 April 13


TMJ

. Saturday 13 April 13


Implants

Initial Assessment

. Saturday 13 April 13


Locator Overdenture Case Treatment Planning Vertical dimension appears satisfactory on the OPG view. BUT......

. Saturday 13 April 13


Treatment Planning Cross section of ridge shows inadequate width despite good soft tissue ridge form

. Saturday 13 April 13


Treatment Planning

. Saturday 13 April 13


Maximising Prognosis

. Saturday 13 April 13


Implant Planning Software Options

Viewing only

Diagnosis

CoDiagnostics

Diagnosis

Implant Simulation Model Based Stent Model Based Guide

Simplant

Diagnosis

Implant Simultation

NobelGuide

Diagnosis

Implant Simulation

Lithiographic Model Lithiographic Model

. Saturday 13 April 13

Scan Generated Model Scan Generated Model


Implant Planning Software Options

. Saturday 13 April 13


Treatment Planning

. Saturday 13 April 13


Saturday 13 April 13


Saturday 13 April 13


Treatment Planning

Vertical Dimension Increase, ID Nerve Lateralisation, Implants, Cerec

. Saturday 13 April 13


Treatment Planning

. Saturday 13 April 13


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.