Battery Water Deionisation Systems Producing up to 540 litres/hr of high purity water
The Elga Process Water range of battery water deionisation systems produce up to 540 litres/hr of purified water for rechargeable batteries. They provide the pure water you demand at the turn of a tap, efficiently and cost effectively. All systems produce water complying with the strict specifications for battery water, with none of the inconvenience of handling and storing old fashioned carboys or conventional distillation equipment.
Top-it-up 125 and 250 Systems
Floor Standing Cylinder Deionisers
• Wall mounted to maximise efficient use of space
• These systems are regenerable, and cylinders can be replaced in a matter of minutes
• Colour change indicator shows when cartridge is exhausted • No electrical supply required
• Convenient disposable resin cartridges enable change over in seconds
• Two models available depending on the output requirements – Top-itup 250 systems provide twice the output of the Top-it-up 125
• Optional 6 metre coiled delivery line and trigger applicator can be connected to either system
• All floor standing systems are supplied with a spare cylinder as standard, to ensure purified water supply continuity
• Using our own transportation service we will collect the exhausted unit from your premises and replace it with a freshly regenerated cylinder • Optional 9 metre coiled delivery line and trigger applicator can be connected either directly to the system or various points on a piped distribution system
Battery Water System Performance & Dimensions Maximum Operating Temperature
Dimensions
0 C l/h psi bar
Top-it-up 125
60
90
6.0
35
Top-it-up 250
60
90
6.0
35
B119
240
70
4.8
35
880
220
210
18.0
B224
360
70
4.8
35
1095
225
225
34.0
B500
540
70
4.8
35
1130
263
263
50.0
Height mm
Width mm
Depth mm
Weight kg
385
92
110
2.5
660
92
110
4.2
Treated Water Quality Deioniser Model
Conductivity
Resistivity
Residual Solids
Average pH
μS/cm
MΩ-cm
mg/l
Top-it-up 125
<1
<1
<0.5
Neutral
Top-it-up 250
<1
<1
<0.5
Neutral
B119
10 - 50
0.02 - 0.1
<10
4-7
B224
10 - 50
0.02 - 0.1
<10
4-7
B500
10 - 50
0.02 - 0.1
<10
4-7
Output Capacity - Litres Deioniser Model
Feed TDS mg/L
50
150
250
350
450
550
Top-it-up 125
800
270
160
115
90
72
Top-it-up 250
1600
540
320
230
180
145
B119
6730
2245
1350
960
750
610
B224
12500
4200
2520
1805
1400
1080
B500
25800
8600
5160
3690
2870
2350
Notes Capacity guidelines above are to: A 10μS/cm endpoint for Top-it-up 125 and 250 systems. A 50μS/cm endpoint for B119, B224 & B500 systems. System Types Top-it-up 125 and 250 – Disposable cartridges. B119, B224 & B500 – Operate using ELGA Process Water’s resin voucher exchange service. System Monitoring B119, B224 & B500 systems – A battery operated conductivity meter monitors the quality of treated water and indicates when the resins are exhausted, or an optional mains powered conductivity indicator is available. For higher flow rate applications consult ELGA Process Water.
ELGA Process Water Marlow International Parkway, Marlow Buckinghamshire SL7 1YL, UK tel. +44 (0) 1628 897000 fax. +44 (0) 1628 897001 email sales.uk@veoliawater.com www.elgaprocesswater.com
ELGA Process Water Orbital House Redwood Square East Kilbride G74 5PR, UK tel. +44 (0) 1355 588140 fax. +44 (0) 1355 588141 email sales.uk@veoliawater.com www.elgaprocesswater.com
LITR3670 Rev D: 09/10. In keeping with the progressive nature of the company, we reserve the right to amend details without notice
Maximum Maximum flow Operating Deioniser Model Pressure