PRODUCT CATALOG COLOSSO IMPLANTS SYSTEM LIVING THE PRACTICALITY
Working to make the world smile
THE COMPANY Since its founding in 1998, Emfils, a leading provider of dental implants in Brazil, brings to market a product line that meets all the needs of professionals. Its mission is to provide an implant system practical, safe and efficient access to dentists with the best value in the market and, thus, enabling the implant treatment to more people. Since its inception, Emfils is dedicated to enabling continued research to optimize the time of the dentists in their daily practice with maximum security. Their releases always gather what is most modern in the world market, with the characteristic that only Emfils offers: practicality in its design! The production process of Emfils is one of the most advanced in the market. With the latest technology in micromachining, the company ensures accuracy and repeatability of all products it manufactures. Emfils follow the strictest international quality standards, in accordance with ISO 9001, ISO13485, MDD 93/42/EEC and DRC-59 (ANVISA) procedures that ensure accuracy and control of all their products.
STUDY, DEVELOPMENT AND DIVULGATION CENTER FOR COLOSSO IMPLANTS NATO is the center of studies, development and dissemination of the Colosso implants and has a clinical staff and highly qualified technical and scientific. Residents of surgery, prosthesis and graduate students regularly seek professional development in NATO. According to the mission of Emfils, the NATO viable clinically therapy to implant a larger number of people. The Clinical Director of NATO is Professor Dr. Adolfo Embacher Filho. Pioneer changed the paradigms of the implant system in of inserting implants, technical and scientific improvements later adopted by the market and established worldwide. Specialist in Prosthodontics in Implant Dentistry and Doctor of Oral Surgery and Maxillofacial Traumatology in his 30 years of implant dentistry, has performed or supervised more than 15,000 implants.
Procedures Manual - FIRST IMPLANT SYSTEM DEVELOPED in Brazil supported by a doctoral thesis - REASONED IN Simplicity, Security And Convenience Clinic - First implant with surface treatment to the top - The smallest WORLD DENTAL TECHNICIAN KIT (one key)
Training and information. Emfils, committed to lead and provide as much information about their products, has developed a complete Procedures Manual with rich information about the Implant System. In this manual, in addition to knowing specific technical details of each product, you can also study and analyze real clinical cases with photographs that show details of each step, whether surgical or prosthetic.
- Surgical Instruments and Prosthetic OPTIMIZED - CERTIFIED COMPANY - OVER 98% OF CUSTOMER SATISFACTION - SCIENTIFIC SUPPORT AVAILABLE FOR CLINICAL QUESTIONS
SEE in Emfils website MANUAL OF PROCEDURES
INTERNAL HEXAGON IMPLANT cOLOSSO EcI EVOLuTION
SELECTION OF PROSThETIc cOMPONENTS INTERNAL hEXAgON *
STANDARD TRANSMUCOSAL ABuTMENT PTP-3303; PTP-3304; PTP-3305; PTP-3306; PTP-4003; PTP-4004; PTP-4005; PTP-4006; PTP-5003; PTP-5004; PTP-5005; PTP-5006.
screwed prosthesis abutment
*
product
STANDARD HEALING CUP
screw M2
TITANIUM TRANSMUCOSAL ABuTMENT PTC-3302; PTC-3303; PTC-3304; PTC-3305; PTC-3306; PTC-4002; PTC-4003; PTC-4004; PTC-4005; PTC-4006; PTC-5002; PTC-5003; PTC-5004; PTC-5005; PTC-5006.
*
NON-ROTATIONAl TRANSMuCOSAl ABuTMENT PTHC-3302; PTHC-3303; PTHC-3304; PTHC-3305; PTHC-3306; PTHC-4002; PTHC-4003; PTHC-4004; PTHC-4005; PTHC-4006; PTHC-5002; PTHC-5003; PTHC-5004; PTHC-5005; PTHC-5006.
*
CPC-3302; CPC-3303; CPC-3304; CPC-3305; CPC-3306; CPC-4002; CPC-4003; CPC-4004; CPC-4005; CPC-4006; CPC-5002; CPC-5003; CPC-5004; CPC-5005; CPC-5006.
switching same plat. prosthetic attachment
*
TITANIUM ANGLED TRANSMUCOSAL ABuTMENT PTA-33153; PTA-33154; PTA-33155; PTA-33156; PTA-33203; PTA-33204; PTA-33205; PTA-33206; PTA-40153; PTA-40154; PTA-40155; PTA-40156; PTA-40204; PTA-40205; PTA-40206; PTA-40207; PTA-50153; PTA-50154; PTA-50155; PTA-50156; PTA-50204; PTA-50205; PTA-50206; PTA-50207.
STANDARD AESTHETIC HEALING CUP
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
CEC-3342; CEC-3343; CEC-3344; CEC-3345; CEC-3346; CEC-4052; CEC-4053; CEC-4054; CEC-4055; CEC-4056; CEC-5062; CEC-5063; CEC-5064; CEC-5065; CEC-5066.
* 30 N.cm prosthetic torque
7,0mm
8,5mm
10,0mm
11,5mm
13,0mm
14,5mm
16,0mm
Surgical maximum torque
Ø 3,3mm 3307
3308
3310
3311
3313
3314
3316
90
N.cm
Surgical maximum torque
Ø 4,0mm 4007
4008
4010
4011
4013
4014
4016
90
cemented prosthesis abutment
70
N.cm
TRANSFER ABuTMENT CLOSED TRAY PTMF-3312; PTMF-4012; PTMF-5012.
TRANSFER ABuTMENT OPEN TRAY PTMA-3312; PTMA-4012; PTMA-5012.
N.cm
Surgical maximum torque
Ø 5,0mm 5007
5008
5010
5011
5013
5014
5016
TRANSFER ABuTMENT WITh REMOVABlE HEXAGON PTHR-3312; PTHR-4012; PThR-5012.
ANAlOg OF INTERNAl HEXAGON IMPLANT ECI AND CRC EVOLUTION ACI-3310; ACI-4010; ACI-5010.
TRANSFER ABuTMENT ClOSED TRAy FOR PTP
TRANSFER ABuTMENT OPEN TRAy FOR PTP
TFPTP-4013; TFPTP-5013.
TAPTP-4013; TAPTP-5013.
clinical
laboratory
STANDARD TRANSMUCOSAL ABuTMENT PROTECTION
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENT
PPP-4004; PPP-5004.
BuRNOuT ABuTMENT WITH CrCoMo EDGE OF ThE TRANSMuCOSAl STANDARD
PTPA-4010; PTPA-5010.
BuRNOuT ABuTMENT OF ThE TRANSMuCOSAl STANDARD PEPP-4015; PEPP-5015.
PElP-4015; PElP-5015.
TRANSFER ABuTMENT TRANSMUCOSAL ClOSED TRAy FOR PTC
TRANSFER ABuTMENT TRANSMUCOSAL OPEN TRAy FOR PTC
PROTECTI ON FOR ThE TITANIUM TRANSMUCOSAL ABuTMENTS
PTT-4012; PTT-5012.
PTTA-4012; PTTA-5012.
PPT-4004; PPT-5004.
BuRNOuT ROTATIONAl ABuTMENT WITh CrCoMo EDgE OF ThE TRANSMUCOSAL
ANAlOg OF ThE TITANIuM TRANSMUCOSAL ABuTMENT PTCA-4012; PTCA-5012.
BuRNOuT ABuTMENT OF THE TRANSMUCOSAL PPET-4015; PPET-5015.
PlET-4015; PlET-5015.
TRANSFER ABuTMENT ClOSED TRAy FOR PThC
TRANSFER ABuTMENT OPEN TRAy FOR PThC
TFPThC-4013; TFPThC-5013.
TAPThC-4013; TAPThC-5013.
PROTECTI ON FOR NON-ROTATIONAl TRANSMUCOSAL ABuTMENTS
ANAlOg OF ThE NON-ROTATI ONAl TRANSMUCOSAL ABuTMENT
PPT-4004; PPT-5004.
PThCA-4012; PThCA-5012.
BuRNOuT NON-ROTATI ONAl ABuTMENT WITh CrCoMo EDgE OF ThE NON-ROTATIONAl TRANSMUCOSAL
BuRNOuT NON-ROTATIONAl ABuTMENT OF ThE NON-ROTATIONAl TRANSMUCOSAL PETh-4015; PETh-5015.
PlETh-4015; PlETh-5015.
TRANSFER ABuTMENT ClOSED TRAy FOR ANglED TRANSMUCOSAL
TRANSFER ABuTMENT OPEN TRAy FOR ANglED TRANSMUCOSAL
TRANSMUCOSAL ANglED ABuTMENT PROTECTION
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENT
TFPTA-5012; TFPTA-6012.
TAPTA-5012; TAPTA-6012.
PPTA-5051; PPTA-6051.
PTAA-5013; PTAA-6013.
BuRNOuT ROTATI ONAl ABuTMENT WITh CrCoMo EDgE OF ThE ANglED TRANSMUCOSAL
BuRNOuT ABuTMENT OF ThE ANglED TRANSMUCOSAL PETA-5015; PETA-6015.
PlETA-5015; PlETA-6015.
15°
PPL-3314; PPL-4014; PPL-5014; PPC-3311; PPC-4011; PPC-5011.
ANglED ADJuSTABlE ABuTMENT WITh BAND PAC-33151; PAC-33152; PAC-33153; PAC-33251; PAC-33252; PAC-33253; PAC-40151; PAC-40152; PAC-40153; PAC-40251; PAC-40252; PAC-40253; PAC-50151; PAC-50152; PAC-50153; PAC-50251; PAC-50252; PAC-50253. 15°
*
hEXAgONAl ABuTMENT PHC-3302; PHC-3304; PHC-3306; PHC-4002; PHC-4004; PHC-4006; PHC-5002; PHC-5004; PHC-5006.
25°
*
ADJuSTABlE ANglED ABuTMENT PAC-3315; PAC-4015; PAC-5015; PAC-3325; PAC-4025; PAC-5025.
TITANIuM ABuTMENT WITh HEXAGON PTCh-3315; PTCh-4015; PTCh-5015.
*
BuRNOuT ABuTMENT WITh CrCoMo EDGE AND HEXAGON
TITANIuM ABuTMENT WITHOUT HEXAGON
O´RING RETENTION ABuTMENT
PTSh-3315; PTSh-4015; PTSh-5015.
PRO-3301; PRO-3302; PRO-3303; PRO-3304; PRO-3305; PRO-3306; PRO-4001; PRO-4002; PRO-4003; PRO-4004; PRO-4005; PRO-4006; PRO-5001; PRO-5002; PRO-5003; PRO-5004; PRO-5005; PRO-5006.
*
BuRNOuT ABuTMENT WITh CrCoMo EDGE WITHOUT HEXAGON
PPlEh-3315; PPlEh-4015; PPlEh-5015. PPlE-3315; PPlE-4015; PPlE-5015.
*
prosthesis over denture
ADJuSTABlE STANDARD ABuTMENT
*
*
cemented or screwed prosthesis
*
*
25°
*
*
ADJuSTABlE AESThETIC ABuTMENT
BuRNOuT ABuTMENT WITH HEXAGON
BuRNOuT ABuTMENT WITHOUT HEXAGON
PEC-3311; PEC-4011; PEC-5011.
PPCh-3315; PPCh-4015; PPCh-5015.
PPSh-3315; PPSh-4015; PPSh-5015.
O´RINg RETENTION BuRNOuT MINI-ABuTMENT MPPO-3010
INTERNAL HEXAGON IMPLANT cOLOSSO cRc EVOLuTION
SELECTION OF PROSThETIc cOMPONENTS INTERNAL hEXAgON *
STANDARD TRANSMUCOSAL ABuTMENT PTP-3303; PTP-3304; PTP-3305; PTP-3306; PTP-4003; PTP-4004; PTP-4005; PTP-4006; PTP-5003; PTP-5004; PTP-5005; PTP-5006.
screwed prosthesis abutment
*
product
STANDARD HEALING CUP
screw M2
TITANIUM TRANSMUCOSAL ABuTMENT PTC-3302; PTC-3303; PTC-3304; PTC-3305; PTC-3306; PTC-4002; PTC-4003; PTC-4004; PTC-4005; PTC-4006; PTC-5002; PTC-5003; PTC-5004; PTC-5005; PTC-5006.
*
NON-ROTATIONAl TRANSMuCOSAl ABuTMENT PTHC-3302; PTHC-3303; PTHC-3304; PTHC-3305; PTHC-3306; PTHC-4002; PTHC-4003; PTHC-4004; PTHC-4005; PTHC-4006; PTHC-5002; PTHC-5003; PTHC-5004; PTHC-5005; PTHC-5006.
*
CPC-3302; CPC-3303; CPC-3304; CPC-3305; CPC-3306; CPC-4002; CPC-4003; CPC-4004; CPC-4005; CPC-4006; CPC-5002; CPC-5003; CPC-5004; CPC-5005; CPC-5006.
switching same plat. prosthetic attachment
*
TITANIUM ANGLED TRANSMUCOSAL ABuTMENT PTA-33153; PTA-33154; PTA-33155; PTA-33156; PTA-33203; PTA-33204; PTA-33205; PTA-33206; PTA-40153; PTA-40154; PTA-40155; PTA-40156; PTA-40204; PTA-40205; PTA-40206; PTA-40207; PTA-50153; PTA-50154; PTA-50155; PTA-50156; PTA-50204; PTA-50205; PTA-50206; PTA-50207.
STANDARD AESTHETIC HEALING CUP
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
CEC-3342; CEC-3343; CEC-3344; CEC-3345; CEC-3346; CEC-4052; CEC-4053; CEC-4054; CEC-4055; CEC-4056; CEC-5062; CEC-5063; CEC-5064; CEC-5065; CEC-5066.
* 30 N.cm prosthetic torque
7,0mm
8,5mm
10,0mm
11,5mm
13,0mm
14,5mm
16,0mm
Surgical maximum torque
Ø 3,3mm 3307
3308
3310
3311
3313
3314
3316
90
N.cm
Surgical maximum torque
Ø 4,0mm 4007
4008
4010
4011
4013
4014
4016
90
cemented prosthesis abutment
70
N.cm
TRANSFER ABuTMENT CLOSED TRAY PTMF-3312; PTMF-4012; PTMF-5012.
TRANSFER ABuTMENT OPEN TRAY PTMA-3312; PTMA-4012; PTMA-5012.
N.cm
Surgical maximum torque
Ø 5,0mm 5007
5008
5010
5011
5013
5014
5016
TRANSFER ABuTMENT WITh REMOVABlE HEXAGON PTHR-3312; PTHR-4012; PThR-5012.
ANAlOg OF INTERNAl HEXAGON IMPLANT ECI AND CRC EVOLUTION ACI-3310; ACI-4010; ACI-5010.
TRANSFER ABuTMENT ClOSED TRAy FOR PTP
TRANSFER ABuTMENT OPEN TRAy FOR PTP
TFPTP-4013; TFPTP-5013.
TAPTP-4013; TAPTP-5013.
clinical
laboratory
STANDARD TRANSMUCOSAL ABuTMENT PROTECTI ON
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENT
PPP-4004; PPP-5004.
BuRNOuT ABuTMENT WITH CrCoMo EDGE OF ThE TRANSMuCOSAl STANDARD
PTPA-4010; PTPA-5010.
BuRNOuT ABuTMENT OF ThE TRANSMuCOSAl STANDARD PEPP-4015; PEPP-5015.
PElP-4015; PElP-5015.
TRANSFER ABuTMENT TRANSMUCOSAL ClOSED TRAy FOR PTC
TRANSFER ABuTMENT TRANSMUCOSAL OPEN TRAy FOR PTC
PROTECTI ON FOR ThE TITANIUM TRANSMUCOSAL ABuTMENTS
PTT-4012; PTT-5012.
PTTA-4012; PTTA-5012.
PPT-4004; PPT-5004.
BuRNOuT ROTATIONAl ABuTMENT WITh CrCoMo EDgE OF ThE TRANSMUCOSAL
ANAlOg OF ThE TITANIuM TRANSMUCOSAL ABuTMENT PTCA-4012; PTCA-5012.
BuRNOuT ABuTMENT OF THE TRANSMUCOSAL PPET-4015; PPET-5015.
PlET-4015; PlET-5015.
TRANSFER ABuTMENT ClOSED TRAy FOR PThC
TRANSFER ABuTMENT OPEN TRAy FOR PThC
TFPThC-4013; TFPThC-5013.
TAPThC-4013; TAPThC-5013.
PROTECTI ON FOR NON-ROTATIONAl TRANSMUCOSAL ABuTMENTS
ANAlOg OF ThE NON-ROTATI ONAl TRANSMUCOSAL ABuTMENT
PPT-4004; PPT-5004.
PThCA-4012; PThCA-5012.
BuRNOuT NON-ROTATI ONAl ABuTMENT WITh CrCoMo EDgE OF ThE NON-ROTATIONAl TRANSMUCOSAL
BuRNOuT NON-ROTATIONAl ABuTMENT OF ThE NON-ROTATIONAl TRANSMUCOSAL PETh-4015; PETh-5015.
PlETh-4015; PlETh-5015.
TRANSFER ABuTMENT ClOSED TRAy FOR ANglED TRANSMUCOSAL
TRANSFER ABuTMENT OPEN TRAy FOR ANglED TRANSMUCOSAL
TRANSMUCOSAL ANglED ABuTMENT PROTECTION
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENT
TFPTA-5012; TFPTA-6012.
TAPTA-5012; TAPTA-6012.
PPTA-5051; PPTA-6051.
PTAA-5013; PTAA-6013.
BuRNOuT ROTATI ONAl ABuTMENT WITh CrCoMo EDgE OF ThE ANglED TRANSMUCOSAL
BuRNOuT ABuTMENT OF ThE ANglED TRANSMUCOSAL PETA-5015; PETA-6015.
PlETA-5015; PlETA-6015.
15°
PPL-3314; PPL-4014; PPL-5014; PPC-3311; PPC-4011; PPC-5011.
ANglED ADJuSTABlE ABuTMENT WITh BAND PAC-33151; PAC-33152; PAC-33153; PAC-33251; PAC-33252; PAC-33253; PAC-40151; PAC-40152; PAC-40153; PAC-40251; PAC-40252; PAC-40253; PAC-50151; PAC-50152; PAC-50153; PAC-50251; PAC-50252; PAC-50253. 15°
*
25°
*
ADJuSTABlE STANDARD ABuTMENT
ADJuSTABlE ANglED ABuTMENT
PHC-3302; PHC-3304; PHC-3306; PHC-4002; PHC-4004; PHC-4006; PHC-5002; PHC-5004; PHC-5006.
PAC-3315; PAC-4015; PAC-5015; PAC-3325; PAC-4025; PAC-5025.
TITANIuM ABuTMENT WITh HEXAGON PTCh-3315; PTCh-4015; PTCh-5015.
*
BuRNOuT ABuTMENT WITh CrCoMo EDGE AND HEXAGON
PTSh-3315; PTSh-4015; PTSh-5015.
*
BuRNOuT ABuTMENT WITh CrCoMo EDGE WITHOUT HEXAGON
PPlEh-3315; PPlEh-4015; PPlEh-5015. PPlE-3315; PPlE-4015; PPlE-5015.
*
O´RING RETENTION ABuTMENT
TITANIuM ABuTMENT WITHOUT HEXAGON
prosthesis over denture
ADJuSTABlE STANDARD ABuTMENT
*
*
cemented or screwed prosthesis
*
*
25°
PRO-3301; PRO-3302; PRO-3303; PRO-3304; PRO-3305; PRO-3306; PRO-4001; PRO-4002; PRO-4003; PRO-4004; PRO-4005; PRO-4006; PRO-5001; PRO-5002; PRO-5003; PRO-5004; PRO-5005; PRO-5006.
*
*
ADJuSTABlE AESThETIC ABuTMENT
BuRNOuT ABuTMENT WITH HEXAGON
BuRNOuT ABuTMENT WITHOUT HEXAGON
PEC-3311; PEC-4011; PEC-5011.
PPCh-3315; PPCh-4015; PPCh-5015.
PPSh-3315; PPSh-4015; PPSh-5015.
O´RINg RETENTION BuRNOuT MINI-ABuTMENT MPPO-3010
SELECTION OF PROSThETIc cOMPONENTS INTERNAL hEXAgON
EXTERNAL HEXAGON IMPLANT cOLOSSO IhE EVOLuTION
*
STANDARD TRANSMUCOSAL ABuTMENT
screwed prosthesis abutment
PTPHE-3504; PTPHE-3505; PTPHE-3506; PTPHE-4104; PTPHE-4105; PTPHE-4106; PTPHE-5004; PTPHE-5005; PTPHE-5006.
*
TITANIUM TRANSMUCOSAL ABuTMENT PTCHE-3502; PTCHE-3503; PTCHE-3504; PTCHE-3505; PTCHE-3506; PTCHE-4102; PTCHE-4103; PTCHE-4104; PTCHE-4105; PTCHE-4106; PTCHE-5002; PTCHE-5003; PTCHE-5004; PTCHE-5005; PTCHE-5006.
*
NON-ROTATIONAl TRANSMuCOSAl ABuTMENT PTHCHE-3503; PTHCHE-3504; PTHCHE-3505; PTHCHE-3506; PTHCHE-4103; PTHCHE-4104; PTHCHE-4105; PTHCHE-4106; PTHCHE-5003; PTHCHE-5004; PTHCHE-5005; PTHCHE-5006.
product
STANDARD HEALING CUP
screw M2
CPCHE-3502; CPCHE-3503; CPCHE-3504; CPCHE-3505; CPCHE-3506; CPCHE-4102; CPCHE-4103; CPCHE-4104; CPCHE-4105; CPCHE-4106; CPCHE-5002; CPCHE-5003; CPCHE-5004; CPCHE-5005; CPCHE-5006.
* 30 N.cm prosthetic torque
switching same plat. prosthetic attachment
STANDARD AESTHETIC HEALING CUP
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
CECHE-3542; CECHE-3543; CECHE-3544; CECHE-3545; CECHE-3546; CECHE-4152; CECHE-4153; CECHE-4154; CECHE-4155; CECHE-4156; CECHE-5062; CECHE-5063; CECHE-5064; CECHE-5065; CECHE-5066.
TRANSFER ABuTMENT CLOSED TRAY
6,0mm
7,0mm
8,5mm
10,0mm
11,5mm
13,0mm
14,5mm
16,0mm
70
N.cm
Surgical maximum torque
Ø 3,3mm prosthetic platform 3,5mm
3307
3308
3310
3311
3313
3314
3316
90 N.cm Surgical maximum torque
Ø 4,0mm prosthetic platform 4,1 mm
4007
4008
4010
4011
4013
4014
4016
90
N.cm
Surgical maximum torque
Ø 5,0mm prosthetic platform 5006 5,0 mm
5007
5008
5010
5011
5013
5014
5016
cemented prosthesis abutment
PTMFhE-3512; PTMFhE-4112; PTMFhE-5012.
TRANSFER ABuTMENT OPEN TRAY PTMAHE-3512; PTMAHE-4112; PTMAhE-5012.
ANAlOg OF EXTERNAl HEXAGON IMPLANT HE EVOLUTION ACIhE-3510; ACIhE-4110; ACIhE-5010.
clinical
laboratory
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENT
TRANSFER ABuTMENT ClOSED TRAy FOR PTP
TRANSFER ABuTMENT OPEN TRAy FOR PTP
STANDARD TRANSMUCOSAL ABuTMENT PROTECTI ON
TFPTP-4013; TFPTP-5013.
TAPTP-4013; TAPTP-5013.
PPP-4004; PPP-5004.
BuRNOuT ABuTMENT WITH CrCoMo EDGE OF ThE TRANSMuCOSAl STANDARD
PTPA-4010; PTPA-5010.
BuRNOuT ABuTMENT OF ThE TRANSMuCOSAl STANDARD PEPP-4015; PEPP-5015.
PElP-4015; PElP-5015.
TRANSFER ABuTMENT TRANSMUCOSAL ClOSED TRAy FOR PTC
TRANSFER ABuTMENT TRANSMUCOSAL OPEN TRAy FOR PTC
PTT-4012; PTT-5012.
PTTA-4012; PTTA-5012.
TRANSFER ABuTMENT ClOSED TRAy FOR PThC
TRANSFER ABuTMENT OPEN TRAy FOR PThC
TFPThC-4013; TFPThC-5013.
TAPThC-4013; TAPThC-5013.
PROTECTI ON FOR ThE TITANIUM TRANSMUCOSAL ABuTMENTS
BuRNOuT ROTATIONAl ABuTMENT WITh CrCoMo EDgE OF ThE TRANSMUCOSAL
ANAlOg OF ThE TITANIuM TRANSMUCOSAL ABuTMENT
PPT-4004; PPT-5004.
PTCA-4012; PTCA-5012.
PROTECTI ON FOR NON-ROTATIONAl TRANSMUCOSAL ABuTMENTS
ANAlOg OF ThE NON-ROTATI ONAl TRANSMUCOSAL ABuTMENT
PPT-4004; PPT-5004.
PThCA-4012; PThCA-5012.
BuRNOuT ABuTMENT OF THE TRANSMUCOSAL PPET-4015; PPET-5015.
PlET-4015; PlET-5015.
BuRNOuT NON-ROTATI ONAl ABuTMENT WITh CrCoMo EDgE OF ThE NON-ROTATIONAl TRANSMUCOSAL
BuRNOuT NON-ROTATIONAl ABuTMENT OF ThE NON-ROTATIONAl TRANSMUCOSAL PETh-4015; PETh-5015.
PlETh-4015; PlETh-5015.
15°
*
*
ANglED ADJuSTABlE ABuTMENT WITh BAND
TITANIuM ABuTMENT WITH HEXAGON
PPLHE-3512; PPLHE-4112; PPLHE-5012; PPChE-3510; PPChE-4110; PPChE-5010.
PACHE-35151; PACHE-35152; PACHE-35153; PACHE-35251; PACHE-35252; PACHE-35253; PACHE-41151; PACHE-41152; PACHE-41153; PACHE-41251; PACHE-41252; PACHE-41253; PACHE-50151; PACHE-50152; PACHE-50153; PACHE-50251; PACHE-50252; PACHE-50253.
PTCHHE-3515; PTCHHE-4115; PTChhE-5015.
15°
*
25°
*
ADJuSTABlE STANDARD ABuTMENT
ADJuSTABlE ANglED ABuTMENT
PHCHE-3502; PHCHE-3504; PHCHE-3506; PHCHE-4102; PHCHE-4104; PHCHE-4106; PHCHE-5002; PHCHE-5004; PHCHE-5006.
PACHE-3515; PACHE-4115; PACHE-5015; PAChE-3525; PAChE-4125; PAChE-5025.
cemented or screwed prosthesis
ADJuSTABlE STANDARD ABuTMENT
*
TITANIuM ABuTMENT WITHOUT HEXAGON PTSHHE-3515; PTSHHE-4115; PTShhE-5015.
*
BuRNOuT ABuTMENT WITh CrCoMo EDGE AND HEXAGON
BuRNOuT ABuTMENT WITh CrCoMo EDGE WITHOUT HEXAGON
PPLEHHE-3515; PPLEHHE-4115; PPlEhhE-5015.
PPLEHE-3515; PPLEHE-4115; PPlEhE-5015.
*
*
*
ADJuSTABlE AESThETIC ABuTMENT PEChE-3511; PEChE-4111; PEChE-5011.
BuRNOuT ABuTMENT WITH HEXAGON
BuRNOuT ABuTMENT WITHOUT HEXAGON
PPCHHE-3515; PPCHHE-4115; PPChhE-5015.
PPSHHE-3515; PPSHHE-4115; PPShhE-5015.
prosthesis over denture
*
*
25°
O´RING RETENTION ABuTMENT PROHE-3501; PROHE-3502; PROHE-3503; PROHE-3504; PROHE-3505; PROHE-3506; PROHE-4101; PROHE-4102; PROHE-4103; PROHE-4104; PROHE-4105; PROHE-4106; PROHE-5001; PROHE-5002; PROHE-5003; PROhE-5004; PROhE-5005; PROhE-5006.
Colosso Implants Unique Body Abutment
Colosso Implants Unique O´Ring Evolution
Transfer Abutment of the Colosso Implant Unique Body
Transfer Abutment of the Colosso Implant Unique Body
PTCU-3512
PTCU-3512
Analog of the Colosso Implant Unique Body Abutment
Analog of the Colosso Implant Unique Body O-ring
ACP-3018
product
ACO-3018
screw M2
product
70
70
N.cm
Surgical maximum torque
screw M2
N.cm
SEE in Emfils website MANUAL OF PROCEDURES
Surgical maximum torque
10,0mm
11,5mm
13,0mm
14,5mm
16,0mm
2510
2511
2513
2514
2516
3010
3011
3013
3014
3016
Ø 2,5mm
SEE in Emfils website MANUAL OF PROCEDURES
10,0mm
11,5mm
13,0mm
14,5mm
16,0mm
2510
2511
2513
2514
2516
3010
3011
3013
3014
3016
Ø 2,5mm
Ø 3,0mm
Ø 3,0mm
Drills The drills available in System, aims to facilitate drilling. The drilling with increasing diameters generates less friction, hence less heat, giving the dentist more safety during surgery. More drills provide more options for drilling in surgery at no extra cost.
SEQUÊNCIA DE BROCAS DO SISTEMA Colosso A - Spear Drill 2,0mm (Installation of the Abutment Colosso Evolution or O´ring Colosso Evolution 2.5mm diameter). B - Pilot Drill 2.0/2.5mm C - Helical Drill 2.5mm (Installation of the Colosso Evolution Abutment or O´ring Colosso Evolution 3.0mm diameter).
Spear Drill
D - Pilot Drill 2.5/2.8mm
With 2,0mm diameter this drill is used for accurately initiate the drilling of the surgical cavity and break the resistance of the cortical bone. It features a pointed shape, similar to a spear that favors the stabilization during drilling start.
E - Helical Drill 2.8mm (Installation of the Colosso IHE Evolution, Colosso ECI Evolution or Colosso CRC Evolution 3.3mm diameter). F - Pilot Drill 2.8/3.2mm
Pilot Drill
G - Helical Drill 3.2mm (2.0mm at cortical for endosteal installation of the Colosso CRC Evolution cervical portion).
It features a cylindrical terminal portion of 5.0mm height without cutting edge to provide stability to the partial cut of the next diameter. It has a laser marks corresponding to the length of 7.0 mm.
H - Helical Drill 3.5mm (Installation of the Colosso IHE Evolution, Colosso ECI Evolution or Colosso CRC Evolution 4.0mm diameter).
Helical Drill
I - Helical Drill 3.8mm (2.0mm at cortical for endosteal installation of the Colosso CRC Evolution cervical portion).
The first of the sequence defines the depth of cut, the others enlarge the diameter. They feature laser marks on their body indicating the lengths of the implants Colosso.
J - Helical Drill 4.2mm K - Helical Drill 4.5mm (Installation of the Colosso IHE Evolution, Colosso ECI Evolution or Colosso CRC Evolution 5.0mm diameter).
Visit the Emfils website AND WATCH THE OF IMPLANT SYSTEM HAND’S ON
L - Helical Drill 4.8mm (2.0mm at cortical for endosteal installation of the Colosso CRC Evolution cervical portion).
ECIE, CRCE and IHEE implants 5,0mm implants
4,0mm implants
3,3mm implants
BAPC-2511
BALC-2020
2,5mm implants
BAPC-2811
BAHC-2520
BAPC-3211
BAHC-2820
BAHC-3220 BAHC-3520 BAHC-3820 BAHC-4220 BAHC-4520 BAHC-4820
de 3,0mm implants
ICPE and ICOE implants
NOTE: ON LOW DENSITY BONES (TYPE 4) THE LAST DRILLS RELATED TO EACH DIAMETER SHALL BE USED ONLY ON THE FIRST TWO THIRDS OF THE ARITIFICAL SOCKET. ON HIGH DENSITY BONES (TYPE 1 and 2) THE NEXT DRILL SHALL BE USED ON THE INITIAL FIRST THIRD OF THE ARTIFICIAL SOCKET. * DRILLS TO BE USED FOR TOTAL ENDOSTEAL CRCE INSTALLATION
SEE THE USE OF DRILLS IN IMPLANT SYSTEM HAND’S ON
SuRgIcAL AND PROSThETIc INSTRuMENTS SuRgICAl KIT COLOSSO EVOLUTION ECE-0504
hEXAgONAl KEy 1.2 CHCC-1210; CHLC-1220
The System Colosso Evolution offers to Emfils customers an assembly that makes the Osteointegrable Implant System Colosso the most competitive in the market. Surgical and Prosthetic lets you install all three types of implants that comprise the System: External hexagon, hexagon and Internal Body only. Moreover, it is the only one who has only a 1.2 mm hex wrench, tighten all screws that have the same thread pitch pattern M2. With the tools essential for the implementation of the first surgical procedure, is accompanied by the Intermediate Short and long for the insertion of implants single body, a metal case suitable for sterilization in an oven or autoclave and has universal Torque Tester, which allows measurements of 25 N. up to 75 cm N.cm. The instrumental support of the Surgical Kit is aluminum, accommodates and organizes all drills sequentially instrumental in identifying niches with laser and protected by rings of silicon. The Surgical Kit Colosso Evolution joins technical and scientific knowledge with the already known versatility and practicability of the entire system.
ONE KEY TIghTENS ALL ThE SYSTEM’S ScREwS
It laser markings correspond to 2.0mm, 4.0mm and 6.0mm height related to the cervical porti on of the implants Colosso, allowing they can be used at the height selecti on of the prostheti c, surgical and lab components.
UNIVERSAL TORQUE TESTER TC-0504
• SPEAR DRIll 2,0MM - BAlC-2020 • PIlOT DRIll 2.0/2.5MM - BAPC-2511 • hElICAl DRIll 2.5MM - BAhC-2520 • PIlOT DRIll 2.5/2.8MM - BAPC-2811 • hElICAl DRIll 2.8MM - BAhC-2820 • PIlOT DRIll 2.8/3.2MM - BAPC-3211 • hElICAl DRIll 3.2MM - BAhC-3220 • hElICAl DRIll 3.5MM - BAhC-3520 • hElICAl DRIll 3.8MM - BAhC-3820 • hElICAl DRIll 4.2MM - BAhC-4220 • hElICAl DRIll 4.5MM - BAhC-4520 • hElICAl DRIll 4.8MM - BAhC-4820 • BIDIgITAl KEy ShORT - CBCC-8310 • BIDIgITAl KEy lONg - CBlC-8320
• TORquE TESTER WITh INVERTER AND ADP - TC-0504 • hEXAgONAl KEy 1.2MM ShORT - CHCC-1210 • hEXAgONAl KEy 1.2MM lONg - CHLC-1220 • INTERMEDIATE 2.4MM ShORT - INCC-2415 • INTERMEDIATE 2.4MM lONg - INLC-2420 • INTERMEDIATE 2.0MM ShORT - INCC-2015 • INTERMEDIATE 2.0MM lONg - INLC-2020 • INTERMEDIATE ShORT uNIquE BODy IMPlANT - ICCU-3008 • INTERMEDIATE lONg uNIquE BODy IMPlANT - ILCU-3013 • PARAllElOMETER (2) - PRC-2223 • DEPTh gAugE - PRC-2530 • DRIll EXTENDER - PBC-3055 • INSTRuMENT hOlDER - SIC-0504 • SuRgICAl BOX - ECC-0504
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
Its action inverter, indicated by arrows, is placed on the cable end. It measures from 25 up to 75 N.cm, thus being prosthetic and surgical.
INTERMEDIATE FOR INTERNAl HEXAGON 2,4 mm
IINTERMEDIATE FOR EXTERNAl HEXAGON 2,0 mm
Available in two sizes: Short and long, they are connected to the two body implants Colosso and actuated by the bidigital key or torque tester providing implant placement continuity.
Available in two sizes: Short and long, they are connected to the two body implants Colosso and actuated by the bidigital key or torque tester providing implant placement continuity.
INTERMEDIATE 2.4MM CONTRA-ANglE
BONE ChISEl COlOSSO
Available in two sizes: Short and long they connect the contra-angle to the two body implants Colosso, so they may be installed by motor at a speed of approx. 30 turns/minute.
Available in two sizes: Short and long for Colosso Implants Internal and External hexagon. Intended to remove the bone that eventually may overlay the implant cover cap hindering its removal.
SAFETy RINg KIT
CIRCULAR SCALPEL
INCC-2415; INLC-2420
INCC-2015; INLC-2020
ESL-3320; ESL-4020; ESL-5020 ESC-3310; ESC-4010; ESC-5010
ICCA-2420; ILCA-2425
BCl-3320; BCl-4020; BCl-5020 BCC-3310; BCC-4010; BCC-5010
KASB-0008
SAFETY IN ThE MAKINg OF ARTIFIcIAL ALVEOLAR
While drilling they assure the intended depth for the artificial socket making. fixed on the drill by a screw with hexagon 1.2mm. Avaible in 8 diameters: 2,5mm; 2,8mm; 3,2mm; 3,5mm; 3,8mm; 4,2mm; 4,5mm e 4,8mm.
Available in two sizes Short and long for Colosso Implants Internal and External hexagon. It is used for exposing the implants with keratinized gum over them. * products sold separately from the Surgical Kit
SuRgIcAL AND PROSThETIc INSTRuMENTS
BONE KIT 4 IN 1 KO - 2801P
The Bone Kit 4 in 1 is designed to provide more practicality to the dentist in complex procedures. In one kit you rely on instrumental to graft bone compressor, expander expander bone and bone screw, which allows performing advanced procedures with a single kit. Fully Autoclavable.
DEVELOPED FOR ADVANcED PROcEDuRES PRAcTIcE
gRAFT hAND-DRIVER • graft Kit Case; • hand-Driver; • Drills for short contra-angle,diameters: 1.1mm; 1.3mm and 1.6mm; • Drills for long contra-angle, diameters: 1.1mm; 1.3mm e 1.6mm; • Fixati on rod for the hand-driver screw; • Fixati on rod for the contra-angle screw; • 12 Fixati on screws: - 1,6 x 4,0mm - 2,0 x 4,0mm - 1,6 x 6,0mm - 2,0 x 6,0mm - 1,6 x 8,0mm - 2,0 x 8,0mm - 1,6 x 10,0mm - 2,0 x 10,0mm - 1,6 x 12,0mm - 2,0 x 12,0mm - 1,6 x 14,0mm - 2,0 x 14,0mm • Bone Expander with Thread: - Ø 2,0mm - Ø 2,5mm - Ø 3,0mm - Ø 3,5mm - Ø 4,0mm - Ø 4,5mm • Expander Point: - Ø 2,0mm - Ø 2,5mm - Ø 3,0mm - Ø 3,5mm - Ø 4,0mm - Ø 4,5mm • Compactor Point: - Ø 2,0mm - 3,0mm - Ø 2,8mm - 3,7mm - Ø 3,2mm - 4,2mm - Ø 4,0mm - 5,0mm • Surgical hammer.
CMKE-22106
CMKE-22106 BER-3011; BER-3013; BER-3016 BER-5411; BER-5413; BER-5416 ERgONOMIc DESIgN QuIcK hITch
CPCM-2771 CPCA-2728 PEO-1604 - PEO-2004 PEO-1606 - PEO-2006 PEO-1608 - PEO-2008 PEO-1610 - PEO-2010 PEO-1612 - PEO-2012 PEO-1614 - PEO-2014 EXPR-2025 EXPR-2525 EXPR-3025 EXPR-3525 EXPR-4025 EXPR-4525
used for capturing and fixing the graft screws with Philips connection, the graft hand-Driver has ergonomic design for ease of use and safety procedures. It is also used as the cable ends of expanders and compressors.
SURGICAL HAMMER MAR-1225
PEXP-2070 PEXP-2570 PEXP-3070 PEXP-3570 PEXP-4070 PEXP-4570 PCOM-2030 PCOM-2837 PCOM-3242 PCOM-4050 MAR-1225
LESS TRAuMA IN PROcEDuRE
It is made of stainless steel and contains a Teflon shield that ensures the efficiency of its use with minimal trauma to the procedure. It is optionally used in compressors and expanders.
BONE COMPACTOR KIT KCO-2807A9
BONE EXPANDER KIT KEO-2807A9
BONE EXPANDER KIT WITH THREAD KEOR-2807A9
• Made of stainless hardened steel; • Concave point; • used to lift up the maxillary sinus fl oor; • Acti ve tapered part in 4 diameters (2mm - 3mm; 2,8mm - 3,7mm; 3,2mm - 4,2mm; 4mm - 5mm); • Diameter marking on each instrument side; • Supplied with Compactor Kit Case; • used with hand-driver (CMKE); • Autoclavable.
• Made of stainless hardened steel; • Convex point; • It is used when the bone thickness is thin; the bone expansion is carried out under pressure for the Colosso implant placement; • Acti ve parallel part in 6 diameters (2mm; 2,5mm; 3mm; 3,5mm; 4,0mm e 4,5mm); • Diameter marking on each instrument side; • Supplied with Expander Kit Case; • used with the hand-driver (CMKE); • Autoclavable.
• Made of stainless hardened steel; • With thread to facilitate the inserti on in areas difficult to reach; • used connected to the torque tester; • Active parallel part in 6 diameters (2,0mm; 2,5mm; 3,0mm; 3,5mm; 4,0mm e 4,5mm); • laser marking of the diameter on the base of each instrument and on the end with thread, indicating the depth; • Supplied with Expander Kit Case; • Autoclavable.
BONE gRAFT KIT KE-1585
• graft Kit Case; • hand-Driver; • Drills for short contra-angle, diameters: 1,1mm; 1,3mm e 1,6mm; • Drills for long contra-angle, diameters: 1,1mm; 1,3mm e 1,6mm; • Fixati on rod for the hand-driver screw; • Fixati on rod for the contra-angle screw; • 12 Fixati on screws: 1,6 x 4,0mm - 2,0 x 4,0mm 1,6 x 6,0mm - 2,0 x 6,0mm 1,6 x 8,0mm - 2,0 x 8,0mm 1,6 x 10,0mm - 2,0 x 10,0mm 1,6 x 12,0mm - 2,0 x 12,0mm 1,6 x 14,0mm - 2,0 x 14,0mm • Autoclavable.
Product Catalog 2011. Issue 1. illustrative images. Products may change without notice.
Resellers, products and Emfils services: www.emďŹ ls.com SAC Itu (Company) Rio de Janeiro SĂŁo Paulo Campinas Portugal Peru
0800 772 8910 + 55 (11) 4813.8900 + 55 (21) 2421.1975 + 55 (11) 2628.1371 + 55 (19) 2511.6664 +351 22 832 3845 +511 625 9743