The New Cleaning Standards for Evaporators & Condensers


IT'S CLEA


Healthy Air & Air Conditioning Best Performance?

ANING TIME


MAINTENAN CLEANING of air conditioning system

»

The temperature regulation in domestic, recreational or working spaces is one of the themes that, since 70s, has involved more and more specialized technicians, manufacturers of air conditioning systems and developers in order to create more performing machines, with low consumption and with an attractive design to become an integral part of furnishings of various locations. However, only in the last decade, awareness of the need and benefits of proper maintenance developed for the consumer, and especially among specialized technicians. If initially these systems were rather simple because they consist of one condenser for each evaporator, today there is no longer a 1 to 1 ratio. There are now singlephase multi-zone systems for residential systems or small industrial systems and large industrial systems VRF (Variable Refrigerant Flow) where a large number of evaporators can be connected to a single condensing unit. Furthermore, these systems are increasingly heat pumps able to introduce both hot and cold air into the environment.


NCE

and

5


MAINTENAN IMPORTANCE

"

If the size of the system is directly proportional to its cost, the maintenance, however, has nothing to do with it. In fact, all the systems, each one in its specificity, require regular and periodic cleaning and maintenance of both the external and the internal units, in order to preserve optimal working conditions and to guarantee the quality of the air supplied into the rooms. Clearly, the cleaning of splits, which are inserted in visible areas of working and domestic spaces, requires diligence and greater care to avoid damaging the surrounding spaces. During the assessment on the specificity of the cleaning of air conditioning systems, another factor to be taken into consideration is the size of devices and, consequently, of their internal components which have gradually reduced their dimensions. The smaller the area to clean, the more demanding and difficult should be its cleaning. For this reason, the intervention of specialized technicians, who use specific and technologically adequate tools, is required. The lack of maintenance of systems or improper practices can lead to insufficient performance, poor air quality and premature damages of the system and its components.

6


NCE E

The appropriate and periodic cleaning is the basic challenge to guarantee the maximum performance and efficiency of the system, the correct indoor air temperature and its healthyness. 7


ADVAN

MAIN

+

Energy efficiency System performance Breakage prevention Longevity of the system Air quality

8


NTAGES of a CORRECT NTENANCE The old proverb "If it is not broken, do not fix it" is not applicable to air conditioning systems. Any professional technician can confirm the existence of problems in the air conditioning systems, which could have been easily avoided with adequate preventive maintenance. The solution to obtain the results, which are expected from correct maintenance, is to follow procedures to improve the condition of the equipment and to test any imminent problems without damaging the system or the surrounding space. Proper maintenance procedures can improve:

- Energy efficiency: clean and properly maintained systems produce more BTUs per Watt of input with obvious savings on utility bills for the consumer. - System performance (comfort): the dirt accumulated on finned coils and on a fan can quickly lead to the decrease of the heat exchange and to the reduction of the air output level Furthermore it becomes more difficult to control the temperature and umidity may develop. - Breakage Prevention: prevention of any kind of breaks by the cleaning procedures and inspections, should be the top priority of any successful maintenance. Besides the right qualification of the maintenance technician is extremely important in order to avoid any problem or damage during cleaning and maintenance. - Longevity of the system: correct maintenance can extend the system's life time by identifying imminent serious problems and risolve situations that can cause abnormal usury. - Air quality delivered into rooms: the

cleaner the split the cleaner the room air. It is necessary to remove dirt, pollen, dust, grease, growth of microbes and molds before air quality start to worsen. Unpleasent odor when turning on the conditioning systems can be an obvious symptom of this problem. The purpose of a technician, who is about to start a cleaning operation, should be to maintain and to improve these requirements. BEFORE starting the maintenance (where it is possible), he should inform the customer of the actual system's condition and the problems that have to be resolved. These processes of accurate checkup, cleaning, maintenance and postmaintenance confirmation of the improvements obtained, can guarantee that the work has been carried out correctly and to attract its attention to the importance of appropriate and scheduled maintenance in order to minimize the risk of system failure.


FREQUENCY air conditioning

CLEANING an MAINTENANC

*

It is recommended to carry out cleaning and maintenance of external and internal units AT LEAST WITH EVERY SEASONAL CHANGE, before switching on and after switching off the system. If it is a heat pump servicing should be carried out when changing from heating to cooling mode. It is advisable that the technician proposes a more regular cleaning and maintenance program depending on the system's location. Particularly oxidized and highly dirty environments request more frequent intervention.


for correct

nd

CE


EQU PERSONAL PROTECTIVE EQUIPMENT During the air conditioning cleaning and its maintenance, it is necessary to wear adequate personal equipment in order to protect yourself from any contact with potentially dangerous substances. These tools are safety glasses and gloves. To ensure adequate protection, it is advisable to check the hazard instructions and warnings indicated on labels, technical and safety data sheets of each cleaner.

12


UIPMENT and TOOLS for air conditioning cleaning 13


A/C PROTECTIVE COVERS Sometimes mini-splits can be particularly complicated to disassemble. Therefore cleaning may be difficult and intervention might take more time, furthermore very expensive damages could appear. Errecom is proud to present the solution for this problem: WALLY*. A transparent polyethylene (PE) cover that ensures complete protection for the area around the mini-split during cleaning operations. Thanks to WALLY the technician can clean the evaporator and its heat exchanger with a minimum disassembly, leaving the split on the wall. Cleaner, rinsing water and dirt will flow into the 20-litre bucket (included in the kit of no.10 covers), without damaging the surrounding surfaces.

*not for sale in the USA

14


How to apply WALLY:

1. Make sure that the mini-split is

properly and completely covered.

2.

Make sure to tighten the closing slider correctly in order to avoid splashing and dirt leaks.

3.

Insert Wally's drainpipe into the bucket, supplied with every kit, to ensure drainage and the collection of dirt accumulated during cleaning process.

For the cleaning of ceiling air conditioners, Errecom offers CEILY that makes it possible - thanks to its reusable metal frame - to clean these types of air conditioners without any risk of damaging the ceiling and the underlying floor. In presence of delicate adjacent surfaces, the use of additional protective sheets is highly recommended.

15


CLOTHES It is always useful to have handy some microfiber clothes or sponge when cleaning the cases and the condensate drain pans in order to remove any water droplets. It’s useful to keep in mind that, in case of particularly difficult dirt, the mechanical action increases the cleaning power of the cleaner.

SOFT BRISTLE BRUSHES Soft bristle brushes are particularly suitable for removing the most intense dirt from the pipes. Small brushes can be useful to reach the dirt settled in extremely narrow points.

Double White Brush

Art.-Nr.

RL1035.01

€ -

-

-

Green Brush

Art.-Nr.

RL1034.01

16

€ -

-

-


Wally

Mini-Split Cover

Art.-Nr.

PM1006.01

PM1006.S1

Description

Bucket with 15 Wally

Box with 15 Wally

€ -

15

-

-

15

-

Ceily

PE Cover for Ceiling Air Conditioner Cleaning

CEILY is a plastic cover with a metal frame specifically designed to guarantee the cleaning operation of ceiling air conditioner without dirtying the surrounding area. CEILY is delivered in a practical bag containing both the metal structure and the protective cover. Spare PE covers are available.

Advantages:

No dirt on surrounding surfaces. Fast and easy installation.

Art.-Nr.

PM1010.01 PM1011.01

Ceily

Description

Spare plastic cover

€ -

01

01

-

-

17


JETGUN OR MANUAL SPRAY PUMPS Very frequent splits or external units are situated in restricted areas, difficult to reach, far from water or energy sources or next to surfaces that should not be damaged. In this case it is important to have available an easy-to-handy and to carry equipment, that provides you with water and cleaner with right pressure and flow. JETGUN is an autonomous system that allows you to spray cleaners or rinse water directly onto the unit to be treated without any additional energy source. It consists of a practical shoulder bag with 3 internal bags and a pressure spray gun. The bags are named accordingly: CLEANER and H2O, in order to easily identify the contents of both. The bags are removable, this you can fill them in the simplest way and wise. In case you use liquid cleaners that need to be deluted with water, thanks to the practical removable bag you can prepare your cleaner immediately in the bag by adding any kind of water available. JETGUN guarantees the best delivery and diffusion of cleaners. It is an indispensable tool to achieve the result of perfect cleaning.

18


JG

Jet Gun

Portable High Pressure Cleaning Machine for A/C Units JET GUN is a practical portable hight pressure water jet machine with shoulder strap specifically developped to be used with acid and alkaline cleaners, difinfectants and water to treat indoor and outdoor air conditioner units. The 3 re-sealable bags included can be filled with acid or alkaline cleaners, disinfectants or water. They can be interchanged quickly according to the desired application. JET GUN works with approx rechargeable battery that allows uninterrupted use for 30 minutes. Thanks to the 6 BAR pressure (85psi) JET GUN increases the cleansing power of the cleaners without damaging the finned batteries of the evaporator and condenser units. Thank to the adjustable nozzle you can easyly change from fan to liquid jet. Features: Discontinued Jet: up to 90 L. Battery features: 12 V-2200 mAh lead rechargeable battery Working pressure: 6 BAR (85 psi) Pipe lenght: 300 cm Including: Battery charger 110-220 V 3 re-sealable and interchangeable 9 L bags for cleaners and water Adjustable spray tip converts from steam to mist. Art.-Nr.

VP1050.01

01

56

Spare parts Art.-Nr.

RPL001.01 Shoulder strap FL1100.01

*Warning: Insert the cleaner after filling the bag with water.

Plastic bag

€ -

01

01 19


CLEANERSfor

air conditioning syste

CLEANING ACID OR ALKALINE CLEANERS? Cleaners are divided into: acid cleaners and alkaline cleaners. A substance is identified as ACID if it has a pH scale from 0 to 7. It is defined basic or ALKALINE, if it has a pH scale from 7 to 14. A substance with a value of pH 7 scale means NEUTRAL, such as distilled water at 25°C.

The best result will be achieved due to the correct choice of the cleaner. It depends on the kind of dirt, the type of surface to be treated, and the pH scale of the cleaner. ACID CLEANERS are indicated to remove limescale deposits, such as saline-type INCRUSTATIONS, rust, cement, gypsum residues and the residues of other types of rigidities . However, an acid product tends to corrode the alloys with which it comes in contact. Therefore, it is essential to ensure its complete removal by an abundant rinsing. ALKALINE CLEANERS are indicated for removing ENVIRONMENTAL DIRT, ORGANIC RESIDUES, fats, oils or residues caused by smog. It is necessary to pay attention to the AGGRESSIVITY OF THE PRODUCT. If the cleaner is too aggressive, you run the risk of discolouring the plastics or surfaces of the system.

20


em There are lots of products to clean external and internal units on the market but it is not easy to choose the right one. Without any doubt first of all you should consider its quality. But you should also consider the type of dirt to remove and the surface to treat paying attention to the pH of the product.

LIQUID CLEANERS, CLEANERS IN AEROSOL CAN OR FOAM CLEANERS? The choice of the type of dispersion, in order to remove more effectively the dirt, is also very important. There are liquid cleaners, cleaners in aerosol cans and foam cleaners. LIQUID CLEANERS are particularly suitable for removing dirt that needs to be wet (ex. earthy dirt). These cleaners are very cheap and easily to dose during preparation and application. They can be used either with trigger, with manual spray pumps or with pressure guns. This kind of cleaner is the most recommanded solution for medium-large systems. LIQUID CLEANERS IN AEROSOL CAN are the best solution for removing dirt that requires high release power (ex. greasy dirt). Thanks to the constant pressure exerted, the cleaner penetrates deeply able to reach even narrowest places. Excellent solution for cleaning operations on medium-small systems and for quick cleaning in closed environments thanks to the quick dry. FOAM CLEANERS IN AEROSOL CAN enable perfect adhesion of the cleaner even on parts where liquid flows down. The expanding foam is incorporating dirt even very difficulti to reach, wets and detaches it. A rinsing is needed to speed up the removal of the foam. For this reason, the use of foamy cleaners is often recommended combined with liquid cleaners in aerosol cans. Foamy cleaners are also particularly suitable for cleaning of medium-small systems.

ERRECOM supplies a complete range of acid and alkaline cleaners, in foamy, liquid, and aerosol forms, specifically designed for cleaning of internal units, filters, external units and condensate drains. 21


of


ACTIONS for the proper

CLEANING INTERNAL UNITS


CLEANING FILTERS The indoor unit filters are the main receptacle for dust, grease and contaminating particles which, if not properly eliminated, are reintroduced into the ambience together with the cooled or heated air by the air conditioner. You cannot clean filters perfectly and remove all particles that cause unpleasent odors by using only water. For proper cleaning, it is necessary to: - remove the air filters from their place. - rinse the filter with water by sliding it in the opposite direction to the air flow, removing the most superficial layer of dust. - spray the specific CHINOOK filter cleaner over the entire filter. - leave for 5 minutes. - rinse. - wait until the filter is completely dried before mounting. It is possible to speed up drying of the filter using compressed air, taking care not to damage the filter itself due to extremely strong air jet.

24


C

Chinook

Indoor Units Filter Cleaner

CHINOOK is a cleaner specifically developed for filter cleaning of any type of indoor unit. It is not aggressive but safe for the system components and the technical. Thanks to its rapid and extremely effective application it supplies high satisfaction. CHINOOK easily removes smog, dust and mold, as well as microbial contaminants. CHINOOK has a pleasent scent and is ready to use (dilution not necessary). Benefits: Easy to remove smog, dust, mold and microbial contaminants. Can destroy origins of unpleasent odors. Removes non-water-like dirt. Suitable for the HACCP plan.

Art.-Nr.

AB1077.K.01

Description

1 Litre Bottle

€ -

06

570 25


EVAPORATOR CLEANING Do not use compressed air or nitrogen during the evaporator and fan cleaning. These could push the dirt even deeper into the system.

1.

Before proceeding with the indoor unit cleaning, it is advisable to ask the customer about the air conditioner performance, to explain him the necessary maintenance and the advantages of an accurate and periodic cleaning.

2.

Examine the working area and protect nearby surfaces if necessary. After customer's permission, remove fragile or delicate objects from the workspace.

3. You can place carefully a ladder or a chair below the workspace if necessary.

4.

Turn the system on to the minimum temperature if permitted by weather conditions and observe the temperature of the air coming out. Use an infrared thermometer to ensure that the temperature is below 12 °C and to have further confirmation of the correct functioning of the system before disassembly.

5.

Pay attention to any unusual noises from the indoor unit.

6.

Before proceeding with the disassembly, it is recommended to inspect visually the evaporator looking for: -correct routing, strapping and installation of electrical cables -correct and safe installation and assembly of the indoor unit -damage on covers and grids -damage on the system fans -bacteria colonies and its smell if present If you reveal something unusual we suggest you to inform the customer so he has the possibility to examine the problem before maintenance.

7.

Disconnect the electricity and check that electric current in the system is disactivated.

26


8.

We recommend reading the disassembly guidelines provided by the manufacturer before maintaining a new system type for the first time. Most manufacturers offer you online portals where you can find service guides and video tutorials to facilitate disassembly and maintenance.

9.

Always wear appropriate PPE when cleaning and maintaining any type of air conditioning system (goggles and gloves).

10.

Remove the external filter cover, the grids and the case following the disassembly instructions provided by the manufacturer in order to access to the finned coils.

11. Protect the area around the split by fixing

WALLY onto the split. Wally is the plastic cover with an quick-action system and an regulatable slider according to the size of the split to be cleaned. Thanks to the shape, the operator can safely clean the evaporator without risking soiling walls or surrounding surfaces. The cleaner, the rinsing water and the dirt will be conveyed into the drainpipe and can freely flow into the collection bucket and then be disposed of according to the current legislation. In case of particularly delicate floors or nearby surfaces, it is suggested to lay protective sheets.

12. Protect the electrical and electronic parts

with an adhesive tape. If an electrical contact gets wet, you should dry them with nitrogen or compressed air.


CLEANING OF FINNED BATTERIES AND METAL COMPONENTS 13.

It is possible to clean the evaporator by using liquid or foamy cleaners in aerosol can. Please refer to the information provided on page 21 to choose the right cleaner according to the necessary action. CLEANERS IN AEROSOL CAN:

PCI

Power Clean - IN

High Pressure Cleaner in Aerosol Can for Air Conditioners POWER CLEAN IN is an evaporator cleaner in a special aerosol can which has been designed to achieve a consistently high delivery pressure able to remove even the most stubborn contamination that accumulates between the finned batteries. In just 10 seconds it guarantees the cleaning of a standard air conditioner (size up to 90 cm). It is available in the following formats:

200 ml (10 seconds of pure power) for 1 indoor unit up to 90 cm. 400 ml (20 seconds of pure power) for 2 indoor units up to 90 cm or 1 indoor unit over 90 cm. 600 ml (30 seconds of pure power) for 3 indoor units up to 90 cm. Benefits Specifically indicated for a correct and frequent cleaning of evaporators. Rinsing not required. It dries off quickly. Art.-Nr.

Description

AB1063.J.01 200 mL Aerosol Can AB1063.N.01 400 mL Aerosol Can AB1063.U.01 600 mL Aerosol Can 28

€ -

12

1008


ECF

Evaporator Cleaner Foam

Foam Cleaner in Aerosol Can for Air Conditioners

EVAPORATOR CLEANER FOAM is a foamy cleaner for air conditioners, which, thanks to its foam formulation, adheres perfectly to the fins of the air conditioner ensuring a high degree of effectiveness. Thanks to its long cannula this foam can penetrate very deeply. It purifies the air distribution duct, incorporating and expelling all contaminating particles (dust, dirt, allergens and microorganisms) which can affect the air quality. It is the perfect way to clean, refresh and purify the A/C system. The synergical action with EVAPORATOR CLEANER guarantees deeper cleaning and faster drying. Benefits Removes contaminating particles even in spots very difficult to reach adhering to surfaces. Releases fresh and clean scent. Suitable for the HACCP plan. Art.-Nr.

Description

€ -

30 24 12

4800 2376 1344

Description

€ -

24 12

2376 1344

AB1049.F.01 100 mL Aerosol Can AB1049.J.01 200 mL Aerosol Can AB1049.N.01 400 mL Aerosol Can

EC

Evaporator Cleaner

Liquid Cleaner in Aerosol Can for Air Conditioners

EVAPORATOR CLEANER is a fast cleaner for air conditioners which purifies an air distribution duct, incorporating and expelling all contaminating particles (dust, dirt, allergens and microorganisms) which can affect air quality and create unpleasent odors. To achieve deep cleaning we recommend the application of EVAPORATOR CLEANER FOAM (left to act 5 minutes)immediately after EVAPORATOR CLEANER. This sequential application will facilitate the foam flow towards the condensate drain ensuring perfect cleaning and reducing drying times of the treated unit. Benefits Quick and effective treatment. Easily directionable jet thanks to the cannula. Leaves fresh and clean scent in the indoor air. Suitable for the HACCP plan.

Art.-Nr.

AB1084.J.01 200 mL Aerosol Can AB1084.N.01 400 mL Aerosol Can


CLEANING OF FINNED BATTERIES AND METAL COMPONENTS LIQUID CLEANERS:

J

Jab

Scented Cleaner for Air Conditioners and Plastic Surfaces JAB is a scented cleaner with fast and effective action, specially formulated for the total cleaning of indoor units. It acts on both air conditioner and plastic surfaces, without damaging them. JAB is the perfect cleaner in areas with food processing. Its composition is biodegradable and little aggressive. In addition JAB is safe for the technical. JAB can be diluted with water up to 1:5, depending on the type of dirt to be removed. The more concentrated in the application the more it will be effective. Benefits Specially developed to clean evaporators and plastics Releases a pleasantly clean scent. Special trigger to change application type quickly from liquid to foamy. Suitable for the HACCP plan.

Art.-Nr.

Description

AB1068.K.01 1 Litre Bottle AB1068.P.01 5 Litres Tank AB1068.D.01 10 Litres Tank 30

€ -

06 02 01

570 168 48


EJ

Eco Jab

Biodegradable Alkaline Cleaner for Air Conditioner ECO JAB is a very effective evaporator cleaner developed with consideration of the environmental protection. It doesn`t contain acids, phosphates, solvents and soda. Thanks to the use of natural surfactants, this product i highly biodegradabile. ECO JAB even surpasses current European laws. It is not aggressively on materials. It is an extremely rapid and effective cleaner to remove organic residues, dust and mold. It is safe for the operator and does not leave harmful traces in the environment. Depending on kind and level of the dirt to be removed, ECO JAB is dilutable with water up to 1:6. The more concentrated in the application the more it will be effective. Benefits High biodegradability. Not perfumed. Particularly suitable for areas with food processing. Special trigger to change application type quickly from liquid to foamy.. Suitable for the HACCP plan.

Art.-Nr.

Description

AB1071.K.01 1 Litre Bottle AB1071.P.01 5 Litres Tank AB1071.D.01 10 Litres Tank

PH7

€ -

06 02 01

570 168 48

PH7 Cleaner

Non-Aggressive Cleaner for Air Conditioners PH7 CLEANER is a delicate, ready to use and vast spectrum cleaner. Due to its special chemical formula and pH it works both on grease and salt layer. Thanks to this technology, PH7 CLEANER can adapt and clean every type of surface. Its rapid action allows it to act effectively and deeply on rigidities, grease and organic residues. After rinsing it is easy to remove. Neutralizes completely any type of unpleasant smell in evaporators. Benefits Non-aggressive due to its neutral pH. Removes bad smells and releases a pleasant clean freshness. Thanks to the special trigger, it can be applied both in liquid and foamy. Suitable for the HACCP plan.

Art.-Nr.

Description

AB1219.K.01 1 Litre Bottle AB1219.P.01 5 Litres Tank AB1219.D.01 10 Litres Tank

€ -

06 02 01

570 168 48 31


UNC

Universal Nano Cleaner

Universal Alkaline Cleaner for Air Conditioners

UNIVERSAL NANO CLEANER is a regenerating, perfumed, fast-acting alkaline cleaner. It removes organic residues and accumulated dirt, avoiding its reappearance. Non-aggressive on surfaces, it can be used frequently to maintain system efficiency. Depending on the type and level of the dirt to be removed, UNIVERSAL NANO CLEANER is dilutable with water up to 1:5. The more concentrated in the application of the more it will be effective. Benefits If used pure, it is ideal for the condenser cleaning. Thanks to the special trigger, it can be applied both in liquid and foamy. Suitable for the HACCP plan.

AB1105.K.01

1 Litre Bottle

€ -

06

AB1105.D.01

10 Litres Tank

-

01

Art.-Nr.

AB1105.P.01

EU

Description

5 Litres Tank

-

570

02

168 48

Evo Ultra

Evaporators Cleaner

EVO ULTRA is a formula of active substances. Deluting it with water you can create an ultimate powerful cleaner for evaporators which can effectively clean the surfaces by removing even the most stubborn deposits of organic residues, grease and incrustations. For a correct use see p.46 32

Art.-Nr.

AB1225.Q.S1

€ -

06

570


C

Clench

Alkaline Evaporator Cleaner with Anticorrosive Protection

CLENCH is a highly performing alkaline cleaner. It was specially developed for evaporators' cleaning that require an important descaling treatment. Its highly alkaline formula makes CLENCH as effective as an acid-based cleaner, removing stubborn saline origin's dirt, but still presenting a great safety level for system components. This product is ideal to restore neglected plants or those ones under severe environment aggression as kitchens, food productions, frying areas or slaughter houses. Depending on the type and level of the dirt to be removed, CLENCH is dilutable with water up to 1:5. More product is concentrated, more effective it is. Benefits Ideal to restore neglected plants. Ideal for system under the environment aggression. Anticorrosive protection. Art.-Nr.

Description

AB1069.K.01 1 Litre Bottle AB1069.P.01 5 Litres Tank AB1069.D.01 10 Litres Tank

€ -

06 02 01

570 168 48

CLEANING OF FINNED BATTERIES AND METAL COMPONENTS TABS CLEANERS:

ET

Evo Tabs

Purifying Cleaner in Tablets for Evaporators EVO TABS is a 20 grams effervescent tablet which, diluted in 5 liters of water, generates an evaporator cleaner having a good purifying action. It removes non-excessive dirt and leaves fresh and clean scent. EVO TABS can be dissolved in any water line, regardless of its hardness: Its formula eliminates limestone excess and leaves no streaks. The obtained cleaner can be dispensed with any usual means of application including spray pumps. Benefits Gentle cleaner for frequent use. 5 liters in 20 grams.

Art.-Nr.

AB1089.01.JA

Description

18 Tablets

€ -

12

33


14.

SANITATION

Whether an aerosol puilitor, PH CLEANER or JAB was used, in addition to cleaning, the fin batteries were also sanitized. If you have used one of the other Errecom products mentioned and intend to sanitize, it is recommended that you apply LUXEDO or SWORD.

L

Luxedo

Scented Purifying Treatment for Evaporators LUXEDO is a regenerative scented treatment for evaporators. Its fast and effective action is optimal for the complete maintenance of the indoor units. LUXEDO removes organic residues and dirt which has been accumulated over the years, slowing down their reappearance. It also has an intense purifying and reconditioning action. It is not aggressive for the surfaces and the operator. The product is also suitable for the HACCP plan. Benefits Specifically designed for evaporator cleaning. Intense purifying and reconditioning action. Suitable for the HACCP plan. Art.-Nr.

Description

AB1073.K.01 1 Litre Bottle AB1073.P.01 5 Litres Tank AB1073.D.01 10 Litres Tank 34

€ -

06 02 01

570 168 48


S

Sword

Scented Revitalizing Cleaner for Evaporators

SWORD is a regenerative and perfumed fast-acting treatment. It has an intense purifying action protecting surfaces from corrosion and ensuring a complete maintenance of the indoor units. SWORD is not aggressive on surfaces and can be used frequently to maintain the efficiency of the air conditioning system. It is safe for the operator and leaves a pleasant fresh fragrance in the air. Depending on the type and level of the dirt, SWORD is dilutable with water up to 1:3. More product is concentrated, more effective it is. Benefits Specifically designed for evaporator cleaning. Intense purifying and reconditioning action. Suitable for the HACCP plan. Art.-Nr.

Description

AB1074.K.01 1 Litre Bottle AB1074.P.01 5 Litres Tank AB1074.D.01 10 Litres Tank

15.

€ -

06 02 01

570 168 48

DISINFECTION

If a disinfectant action is required, apply SANIBACT, the surgical medical presidium by ERRECOM.

SB

SaniBact

Concentrated Disinfectant with Bactericide and Virucidal Efficacy

SANIBACT is a disinfectant Presidio Medico Chirurgico, specifically developed for the cleaning of evaporators, ventilation channels and any surface where a deeper level of disinfection is required. SANIBACT is a highly concentrated product: It should be deluted 1:25. To have more effective result, the product can be used pure, thanks to its special 1L packaging with trigger. ATTENTION: do not use SANIBACT concentrated on surfaces in contact with food. It is effective against the following viruses: Influenza, Hepatitis B/C, HIV, Rota viruses, Noro virus, and Ebola Virus. Concerning the bacteria, SaniBact passes the tests EN1276 EN 13697. For molds, it passes the EN13697 test. Benefits Thanks to its special trigger, it can be applied both in liquid and foamy It guarantees the highest level of hygiene during the cleaning process. Suitable for the HACCP plan.

Art.-Nr.

Description

AB1085.K.01 1 Litre Bottle AB1085.P.01 5 Litres Tank AB1085.D.01 10 Litres Tank

€ -

06 02 01

570 168 48 35


ANTICORROSIVE PROTECTION

16.

It is always recommended to apply an anticorrosion treatment, especially in particularly oxidizing environments.

NAP

No-Age Plus

Anticorrosive Protective Spray Treatment for Air Conditioners

NO-AGE PLUS is an anticorrosive and antioxidant treatment. It has been specially developed to be applied on finned batteries of indoor units (in particularly oxidizing environments), condensers and covers of external units after cleaning operations. Once applied, NO-AGE PLUS forms a transparent and thick protective film, resisting to humidity, smog, salt, sand and dust. Benefits Aerosol treatment for uniform application. Transparency.

Art.-Nr.

Description

AB1103.YW.01 750 mL Aerosol Can 36

€ -

12

672


CASE AND PLASTIC PARTS' CLEANING 17.

It is advisable to clean evaporator plastic parts and their cases with alkaline cleaners. Errecom has evaluated and manufactured a complete range of alkaline evaporator cleaners which guarantee deep and thorough cleaning of splits, each in its specialization. Rinse with water when necessary and leave the cover open for drying.

S

Starlux

Cleaner for Case and Plastic Surfaces STARLUX is a non-aggressive foam cleaner for air conditioning units' plastic and metal cases in one step. It easily removes dust, finger marks, stubborn nicotine, grease and environmental dirt. After covering the surface to be cleaned with a light layer of foam, wipe with a cloth to leave everything clean and tidy. Benefits: Removes general grime, finger marks and grease from plastic and metal surfaces.

Art.-Nr.

AB1226.N.01

€ -

06

570

Note: If it is not integrated in the detergent, use a safe and good quality antimicrobial treatment on the evaporator surface. In some cases, when the fan is too dirty, it may be easier to remove and clean it outside.


CONDENSATE DRAIN AND PUMP CLEANING

18.

For a thorough cleaning of the condensate drain, disconnect the pipe and, with the help of a funnel, pour a small quantity of DRIZZLE in order to remove dirt and obstructions. If the drain is particularly dirty, it is suggested to connect a pump to the condensate drainpipe terminal during the entire evaporator washing operation in order to facilitate the flow of cleaners and the release of the drain. Always clean all the residues in the drain pan and under the exchanger using towels or brushes. If the system has a condensate pump, the pump tank must be removed and cleaned. Assure the cleaning of a float and of a screen if present. Use only nitrogen or CO2 to drain the condensate drain line. Make sure to keep aggressive cleaners outside the pump. Fill and test pump operation before finishing.

19.

Inspect all the cables and pipes inside the evaporator to check for rubbing marks.

20.

Inspect and check the holding of electrical connectors, fins and terminals.

21. Reassemble the components of the unit, leaving

the WALLY still installed the way any residual water can flow out. When reassembling the units, make sure that no cables or sensors were moved or damaged and that no electrical components got wet.

22.

Do a quick test of the indoor unit by turning on again the power and setting the control on the fan. This will ensure that there are no suspicious noises and that excess water can escape from the coil. If you are not familiar with the manufacturer's guidelines to do tests, we advise to review the technical manual to be aware of the specific recommended test procedure. Even though there are some good general testing procedures to follow, nothing can do better than the manufacturer's guidelines, especially for complex systems.

38


D

Drizzle

Drain Tubes Cleaner DRIZZLE is a specific fast-acting and effective chemical product, formulated to remove dirt and clogging of condensate drain tubes in A/C systems. Benefits Removes scale. Removes organic residues. Eliminates molds and algae. It prevents the formation of new clogging. Non-corrosive on metals.

Art.-Nr.

AB1078.K.01

Description

1 Litre Bottle

€ -

06

570

39


40


STEPS

for perfect

EXTERNAL UNIT CLEANING

41


CONDENSER CLEANING 1. Before proceeding with the outdoor unit cleaning, it is advisable

to inquire the customer on the air conditioner performance, to explain how the maintenance will be done and which are the advantages for a correct and periodic cleaning.

2.

Examine the working area and protect nearby surfaces if necessary. On customer's permission, remove fragile or delicate objects from the workspace.

3. Place securely a ladder or a stool in the workspace if necessary. 4.

Turn on the system to minimum temperature and observe the temperature of the air coming out. This information helps to ensure that the system does not have substantial operational problems before starting maintenance. Warning: do not insert a temperature probe into the fan! Use an infrared thermometer.

5. Pay attention to any unusual noise from the outdoor unit. 6.

Before proceeding with the disassembly, it is recommended to inspect visually the condenser looking for: - traces of condensate leaks or related stains nearby the outdoor unit - correct inclination of the condensate drain when visible - correct routing, strapping and installation of electrical cables - correct and safe installation and assembly of the outdoor unit - suitable switch sizes and disconnectors - traces of lubricant visible above or around the condensing unit or to the valves. Such traces can indicate refrigerant gas leaks - damage on covers or grids - damage on the system fans - missing charging valve screws or caps - damaged pipe insulation - bacteria colonies and its unpleasent smell If there is any abnormality, you should better inform the customer in order to make it possible for him to ask you to examine the problem before starting the maintenance.

7.

Disconnect the electricity and check the absence of electrical current in the system. WARNING: the inverter systems contain large capacitors that can hold the electrical charge for a few minutes after the system has been disconnected from the power supply. Be very careful and thoroughly follow the manufacturer's recommendations and safety measures.

42


It is recommended to read the disassembly guidelines provided by the manufacturer before maintaining a new type of a system for the first time. Most manufacturers have online portals where you can find service guides and video tutorials to help you with disassembly and maintenance.

8.

Always wear appropriate PPE when cleaning and maintaining any air conditioning system (goggles and gloves). Cleaning the condenser exchanger is a very critical point in the maintenance of all air conditioning systems, as they often have very close fins that can easily get clogged. It is important to use appropriate cleaners and water at controlled pressure to avoid damaging of the exchanger and electrical components.

9.

Most systems release air from the sides and can be cleaned in the opposite direction to the air flow by removing the front or upper grill. Many technicians clean the condensers from outside to inside: this option is acceptable in those cases where it is difficult to access inside the condenser and the system is not so dirty. In fact, usually it is suggested to wash every component of the system in the opposite direction to the air flow in order to facilitate the escape of accumulated dirt. When the cleaning is done with the air jet, take care not to push the dirt deeper into the exchanger.

10.

If the control panel and motors are in the area to be cleaned, it is advisable to cover them with a plastic cover or with adhesive tape, protecting them from getting wet. If any electrical component gets accidentally wet, nitrogen or compressed air can be used to dry it completely before testing.

43


11.

FINNED BATTERIES CLEANING

Here below is the most efficient cleaning method for finned batteries, according to Errecom experience:

a.

Rinse the exchanger with water, working from top to bottom and in the direction opposite to the air flow, from the inside to the outside.

b. Apply the acid cleaner on the entire exchanger from top to bottom.

44


NAC

Nano Acid Cleaner

Concentrated Acid Cleaner for Condensers

NANO ACID CLEANER is an acid condenser cleaner that, thanks to its formula, effectively descales the treated surface, removing the most stubborn deposits. It is particularly suitable for dissolving the dirt deposited in the cracks of finned batteries. NANO ACID CLEANER can be diluted with water up to 1:8, depending on the type of scale to be removed. More product is concentrated, more effective it is. It is recommended to avoid contact with varnished parts. Rinse thoroughly. Benefits:

Specifically designed for condenser cleaning. Ideal for restoring the efficiency of the condenser heat exchange. Removes the most stubborn incrustations. Thanks to the special trigger, it can be applied in both foamy and liquid form.

Art.-Nr.

AB1107.K.01 AB1107.P.01 AB1107.D.01

AT

Description

1 Litre Bottle 5 Litres Tank 10 Litres Tank

€ -

06 02 01

570 168 48

Acid Tabs

Acid Cleaner in Tablets for Condensers

ACID TABS is an acid cleaner for condensers recommended for frequent use and for the removal of non-deep deposits. With a single 20-gram tablet, 5 L of degreasing and descaling detergent can be produced. It removes limescale and saline excesses (smog, excrements, etc.) releasing a pleasant clean scent. It does not damage materials and plastic surfaces. It is recommended for all those condensers located in seaside or high pollution places that get cleaned frequently. For more resistant dirt it is advisable to dissolve 2-3 Tabs in 5 liters of water to obtain a cleaner with higher cleaning power but still delicate and non-aggressive. ACID TABS can be dissolved in any line water, regardless of its hardness: their formula in fact eliminates limestone excess and leaves no stains. The obtained cleaner can be dispensed with any usual application means including spray pumps. Benefits: Degreasing and descaling cleaner for frequent use. 5 L in 20 grams.

Art.-Nr.

AB1102.01.JA

Description

18 Tabs

€ -

12

45


Ultra Cleaning TECHNOLOGY Acid Ultra, Alkaline Ultra and Evo Ultra are pure active substances specifically developed and formulated to delute with water for the cleaning of AC/R Evaporators and Condensers. We are proud to have created these eco-friendly products, to significantly reduce the quantity of common traditional concentrated cleaners and thus to diminish the impact on the ecosystem. Indeed, Acid Ultra, Alkaline Ultra and Evo Ultra are packed in 250 mL glass bottles to create 5L of cleaner to remove even the most stubborn dirt. The optimal recommended dilution is 50 mL per liter of water. The supplied dispenser allows you to obtain the desired quantity of cleaner with the precision that a so much performing chemical product needs, without diluting the whole product in a single solution. The extraordinary formula of these active substances helps you to overcome the limits of water hardness. In fact, these products can be diluted with any type of water, including very hard ones without leaving any residue on surfaces.

c. Let the acid cleaner act for 5-10 minutes. d. Rinse the acid cleaner. e. Apply the alkaline cleaner on the entire exchanger from top to bottom.


AU

Acid Ultra

Acid Cleaner for Condensers ACID ULTRA is an active substances' formula that diluted with water create an ultimate powerful acid cleaner for condenser able to descale even most stubborn deposits (rust, salt deposits) and restoring the efficiency of the condenser heat exchange. Art.-Nr.

AB1222.Q.S1

AU

€ -

06

570

Alkaline Ultra

Alkaline Cleaner for Condensers

ALKALINE ULTRA is an active substances' formula that diluted with water create an ultimate powerful alkaline cleaner for condenser which can effectively degrease surfaces by removing even most stubborn deposits of organic residues, grease, dust, pollen and smog.

Eco MISSION

Art.-Nr.

AB1223.Q.S1

€ -

06

570

47


NAC

Nano Alkaline Cleaner

Concentrated Alkaline Cleaner for Condensers

NANO ALKALINE CLEANER is an alkaline condenser cleaner that, thanks to its formula, effectively degreases surfaces by removing even most stubborn deposits of organic residues, grease, dust, pollen and smog. NANO ALKALINE CLEANER can be diluted with water up to 1:8 depending on the type of dirt to be removed. More product is concentrated, more effective it is. It is recommended to avoid contact with varnished parts. Benefits Specifically developed for condenser cleaning. Ideal for restoring the efficiency of the condenser heat exchange. Removes stubborn organic residues: grease, dust, pollen and smog. Thanks to the special trigger, it can be applied both in foamy and liquid. Art.-Nr.

Description

AB1106.K.01 1 Litre Bottle AB1106.P.01 5 Litres Tank AB1106.D.01 10 Litres Tank 48

€ -

06 02 01

570 168 48


Alkaline Tabs

AT

Alkaline Cleaner in Tablets for Condensers ALKALINE TABS is an alkaline cleaner for condensers recommended for frequent use and for the removal of not deep deposits. A single 20g tablet produces 5 L of delicate and non-aggressive detergent which releases a pleasant clean scent. It does not damage materials and plastic surfaces. For more resistant dirt it is advisable to dissolve 2-3 Tabs in the 5 liters of water in order to obtain a cleaner with greater cleaning power but still delicate and non-aggressive. ALKALINE TABS can be dissolved in any line water, regardless of its hardness: their formulation in fact eliminates excess limestone and leaves no stains. The cleaner obtained can be dispensed with any usual application means including spray pumps. Benefits Delicate cleaner for frequent use 5 L in 20 grams

Art.-Nr.

AB1221.01.JA

C

Description

18 Tabs

€ -

12

-

Chisel

Alkaline Condenser Cleaner with Anticorrosion Action

CHISEL is a high-performance alkaline cleaner formulated for cleaning condensers that need an intense descaling action. Its strongly alkaline composition allows CHISEL to act like an acid by removing stubborn dirty of saline origin, but it is safer for the system components. The anticorrosive components contained in CHISEL prevents the creation of new points of corrosion. It is the ideal product for neglected and subjected to strong environmental aggression systems. It can be used frequently to maintain the efficiency of the air conditioning system. It can be diluted with water up to 1:3 depending on the type of dirt to remove. More product is concentrated, more effective it is. Benefits Particularly suitable for restoring neglected implants. Suitable for applications in very aggressive environments. It has an anticorrosive action.

Art.-Nr.

Description

AB1070.K.01 1 Litre Bottle AB1070.P.01 5 Litres Tank AB1070.D.01 10 Litres Tank

€ -

06 02 01

570 168 48 49


ER

EcoRestore

Biodegradable Alkaline Condenser Cleaner

ECORESTORE is an effective condenser cleaner designed in complete respect for the environment: it does not contain acids, phosphates, solvents and soda. The biodegradability is guaranteed at very high levels, thanks to the use of natural surfactants: actually, these components have a great level of biodegradability, which is even higher than the one required by the current European laws. It is not aggressive for the materials and is therefore an extremely fast and effective cleaner to remove the most of organic residues, dust and mold. ECORESTORE is safe for the operator and does not leave traces that can be harmful to the environment. ECORESTORE can be diluted with water up to 1:4 depending on the type of dirt to remove. More product is concentrated, more effective it is. Vantaggi Highly biodegradable. Specifically designed to clean condensers. Due to its odourlessness it is particularly suitable for environments with food industry. It can be applied both in liquid and foamy thanks to the special trigger. Suitable for the HACCP plan. Art.-Nr.

Description

AB1072.K.01 1 Litre Bottle AB1072.P.01 5 Litres Tank AB1072.D.01 10 Litres Tank

R

€ -

06 02 01

570 168 48

Restore

Delicate Alkaline Cleaner for Condensers

RESTORE is an efficient scented cleaner for condensers with a non-aggressive formula, recommended for frequent cleaning. Its composition doesn’t damage the materials of the external unit and is safe for technicians. It easily removes environmental dirt. It has a purifying action and is the ideal cleaner for condensers installed in area in contact with food. RESTORE can be diluted with water up to 1:3 depending on the type of dirt to be removed. The more concentrated the product will be used, the more effective it will be. Benefits Made for cleaning delicate surfaces. Suitable for applications in environments where food is present. It can be applied both in liquid and foamy forms thanks to the special trigger.

Art.-Nr.

Description

AB1067.K.01 1 Litre Bottle AB1067.P.01 5 Litres Tank AB1067.D.01 10 Litres Tank 50

€ -

06 02 01

570 168 48


32

page

UNC

Universal Nano Cleaner

Universal Alkaline Cleaner for Condensers

f. Let the alkaline cleaner act for 5-10 minutes. g. Rinse the alkaline cleaner abundantly from top to bottom to remove any residue. Clean any residue

or dirt from the condenser base and the condensate pan.

If you want to clean faster, the dirt is not particularly intense and the condenser is not large, you can use the aerosol can cleaner.

PCO

Power Clean-OUT

High Pressure Cleaner in Aerosol Can for Condensers POWER CLEAN OUT is a condenser cleaner in a special aerosol can which has been designed to achieve a consistently high delivery pressure, that allows removing even most stubborn dirt that accumulates between the plates. POWER CLEAN OUT is indicated for both types of condensers with remote units and integrated ones. Benefits Specifically indicated for a correct and frequent cleaning of condensers. Rinsing is not necessary.

Art.-Nr.

AB1063.YW.01

Description

750 mL Aerosol Can

€ -

12

672 51


PROTECTIVE ANTI-CORROSIVE TREATMENT 12.

It is always advisable to apply a PROTECTIVE ANTI-CORROSIVE TREATMENT after the cleaning operation, since most outdoor units are often installed in poorly protected environments. For this purpose, it is possible to apply

NA

No-Age

Protective-Anticorrosive Treatment for External Units

NO-AGE is a protective treatment, specially develped for all those systems that are exposed in highly oxidizing environments (seaside, heavily polluted sites) where salt and acid rain reduce significantly the condenser life. Once you have cleaned the condenser with acid or alkaline cleaners, spray NO-AGE directly on it: this solution generates a microfilm that does not limit the heat exchange of the condenser, but reduces the ability of dirt (such as salt and smog) to stick on surfaces, protecting the metals thanks to an anticorrosive barrier. Benefits Extends the condenser life. Thanks to the special trigger, it can be applied in both foamy and liquid forms.

Art.-Nr.

Description

AB1100.K.01 1 Litre Bottle AB1100.P.01 5 Litres Tank AB1100.D.01 10 Litres Tank 52

€ -

06 02 01

570 168 48


36

page

NAP

No-Age Plus

Anticorrosive Treatment - Protective Spray for external units

For specific anticorrosive protection of copper pipes, ERRECOM has formulated

NAG

No-Age Gelly

Anticorrosive Protective Treatment for Copper Pipes in A/C Systems

NO-AGE GELLY is an anticorrosive protective treatment with transparent and dense consistency applicable on copper pipes by using a special brush incl. in the packaging. Once applied, NO-AGE GELLY will build a thick and transparent protective film, resistant to moisture, smog, salt, sand and dust. Benefits Spreadable with the appropriate brush. Extends condensers' life time.

Art.-Nr.

Description

AB1104.M.01 500 mL Can

€ -

-

53


13.

A/C CASE CLEANING

50

page

50

page

32

page

If the case consists of metal, we recommand you to use acid or alkaline cleaners, specific for external units and regarding the type of dirt to be removed. If the case consists of plastic, we advise you to proceed with alkaline non-aggressive cleaners for external units, such as:

54

UNC

Universal Nano Cleaner

Universal Alkaline Cleaner for Condensers R

Restore

Delicate Alkaline Cleaner for Condensers ER

EcoRestore

Biodegradable Alkaline Cleaner for Condensers


14.

CONDENSATE DRAIN CLEANING

(in case of HEAT PUMP) Clean the condensate drain with DRIZZLE. Always remove all the residues present in the drain pan and under the exchanger using towels and brushes.

D

Drizzle

Condensate Drainpipes Cleaner DRIZZLE is a specific fast-acting and effective chemical product, formulated to remove dirt and clogging from the condensate drainpipes in A/C systems. Benefits Removes scale. Removes organic residues. Eliminates algae and mold. Prevents the formation of new clogging. Non-corrosive toward metals.

Art.-Nr.

Description

AB1078.K.01 1 Litre Bottle

€ -

06

570

15.

Assemble all the previously dismantled components following the instructions provided by the manufacturer. 55


Leave the system running for at least 10 minutes on ventilation mode, in order to allow it to stabilize and let the exchanger dry before starting any test. The systems have specific charges that can vary basing on the length of the lines at system startup. Therefore we do not recommend connecting pressure gauges to the system during the test. In case that the connection to the refrigeration system is necessary, the best choice for testing ia a pressure gauge or a Bluetooth probe.

56

FUN


CHECKING the correct NCTIONING of air conditioning systems

Subsequent tests should be carried out: - Measure the fan amperage of the compressor and of the condenser at minimum temperature - Measure the voltage - Check the temperature of the condenser line - Measure the temperature of the incoming and outgoing air It is also possible to confirm the cooling capacity (quantity of BTU of heating : use two thermo-hygrographs, one at the inlet and the other at the outlet, to calculate the air temperature. Many Bluetooth probes automatically calculate the cooling capacity which can be verified in the manufacturer's manual. By comparing the manufacturer's data with the actual delivered capacity, it is possible to confirm if the system is working correctly or not. For more detailed tests, it is fundamental to take into consideration the manufacturer's recommendations.

In some cases, if the system seems to be discharged, it is recommended to check the charge several times according to the manufacturer's specifications. If it is allowed by the environmental conditions, let the system work long enough to confirm the production and the correct drainage of the condensate. Make sure there is no condensate dripping or leaking from the split. If the system is a heat pump, test both types of use (hot - cold). Make sure to clean everything inside and outside and carefully check the entire system to confirm that the system is working properly and there are no unusual noises. Make sure that all screws and caps have been placed correctly and that all tools and materials used for cleaning and maintenance have been stored. Record the basic parameters: - Measure the amperage of the compressor, dispenser and CFM - Check the voltage applied - Measure the temperature of the outlet air and delta T - Check the suction pressure and overheating at full cooling Inform the customer that the operation has been completed and explain in detail the work done. Ask the customer with which setting you should leave the device to him.

57


TO DO: - Carefully prepare the area to clean - Clean thoroughly - Protect electrical and electronic components - Use safe and specific cleaners based on the type of dirt and the type of surface to be cleaned - Use specific equipment - Use a safe water pressure level for cleaning operations - Use non-invasive verification methods - Communicate with the customer in order to raise awareness on the need and usefulness of scheduled maintenance and cleaning

NOT TO DO: - Damage surfaces around the system - Adopt the philosophy "If it's not broken, don't fix it" - Compromise the electrical and electronic components with water - Damage fins of the finned coils with aggressive chemicals - Use compressed air or nitrogen on fins - Consider the air conditioning system as a kind of general customary equipment - Not inform the customer of what is being done and the importance of professional and scheduled maintenance.


additional

ADVICES

TIPS - In case of particularly stubborn dirt, remember that the chemical cleaning action of a cleaner can be increased by the mechanical action of the technician. - Sense of cleanliness: every component must be washed in the opposite direction to the air flow in order to facilitate the escape of accumulated dirt. - During the cleaning operation of indoor units, please make sure that there are no individuals or pets present and to enter the room only after having aerated the space. - It is always recommended to use specific products and suitable equipment. 59


Note

60


Note

61


Note

62


63


Vers:EN_01.PULIZIA.20

follow us on

ERRECOM SPA Via Industriale, 14 25030 Corzano (BS) Italy +39 030 971 9096

64

info@errecom.it - errecom.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.