Occupational health and safety in water & wastewater treatment Low bidding and quality data don't mix in iaboratories Landfiil methane now generating 23 megawatts Purifying stormwater — two approaches Deveiopments in flow monitoring Reports from the U.K.
FOR A SAFE ENVIRONMENT CALL US! Ammonia & Nitrate Monitors
Sludge Blanket
Parts Per Million
Level Detectors
Dissolved Oxygen Analyzers
The only blanket interface monitor/controller which automatically retains a clarifier blanket
lyzers with features such as automatic cali
i|^ CtMmtk
Contronlc Development's Ammonia Monitor is based on use of an ion-selective electrode
which measures the concentration of ammo
nia. The principle used involves raising the pH of the sample by the addition of alkali to con
interface following a disturbance, exhibits continuous clarifier profiles on a computer and controls up to four sludge pumps auto
vert ammonium ions to ammonia. The instru
ment's microprocessor converts the electrode output signal to calculate ammonia concentration, while compensating for the temperature of the sample. The result is dis played as Nitrogen {NH4-N).
matically to maintain the desired interface
level.The Model 2500 has no moving parts and
Microprocessor-based dissolved oxygen ana bration, self-diagnostics, stepped current output control, low cost multi-channel elec
tronics, and low maintenance self-cleaning probes. Four channel conversion available. Request Bulletins 9010/9040 and 64/90.
can be virtually maintenance free. Request Bul letin 2500.
Circle 200 on Reader Service Card
Circle 201 on Reader Service Card
BATTERY POWERED HAZARDOUS AREA SAMPLER
ifyoi!i'<reat WAT!
Circle 202 on Reader Service Card
EFFLUENT SAMPLER
A WORLD FIRST IN RISK-FREE WASTE WATER
The EPS 1021 Effluent
Sampler is designed to extract samples of liquid from an open channel or tank and deposit them in
SAMPLING
drinking
either a single composite container or sequentially
The 1511 Zone 1 portable
water...
waste water sampler is a
sanitary sewage...
into an array of
unique world first — the
24 X 1/2 litre containers
only electrically operated (with intrinsically safe power pack) sampler of its type which is fully approved for Zone 1
process water... wastewater
for subsequent retrieval and analysis.
hazardous environments,
^rude sewage
providing an alternative to
* Settled sevwige
traditional pneumatic samplers.
* Final effluent
* Raw sludge * Most industrial effluents
MEETS ALL INTERNATIONAL
STANDARDS The 1511 complies with the many international safety EPS 1021
standards and is certified
Effluent Sampler
by BASEEFA for use in Zone 1 environments with
To MISA Specifications
the following classifica
Circle 204 on Reader Service Card
tions, E Ex ib MB t4.
REGAL
AUTOMATIC LIQUID SAMPLING WHEREVER IS NEEDED
gas chlorinctors* can mean • lower costs • less downtime • faster service
01 1 mpC 0AMDI CD oLUUUt OAmrLtn The EPS 1030 Sludge Sampler
Wide Range of Appllcatlons
is designed to extract samples ot sewage sludge from a flowing
With Up to 60% FEWER parts and only TWO
rDoving parts, REGAL Gos Chlorinators mean lower
sludge holding tank via the tank wall. The machine represents the only really practical method of acquiring sludge samples on a
programmable portable
wastevrater sampler provides cost effective automatic sampling to assist in monitoring municipal and industrial
regular basis and is unique in Its ability to sample sludges containing a high level of nonhomogeneous suspended solids.
wastewater.
used in automatic switchover and remote and
A general purpose unit designed to extract samples of most liquids including crude sewage and even some sludges from an open source and to deposit them into a container or sequentially into an array of 12 or 24
multi-point applications. Available with maximum chlorine flow meter capacities up to 600 lbs ot chlorine feed per 24 hours (10kg per hour}. Don't put it off—put them on! Call or write for details. 'And sulphonalors for dechlorination. Circle 207 on Reader Service Card
NOW WARRANTED 3 YEARS
pipeline or alternatively from a
The EpidOIIT
first costs and lower repair costs. And because they are 100% field-serviceable with same-day factory handling for replacement parts, they mean less downtime and uninterrupted on-line service. REGAL Gas Chlorinators mount directly on the cylinder with special heavy-duty yoke, or can be
Typical Appllcatiotts
* Anaerobic digester feeds/ contents/outputs
* Mechanical dewatering device feeds
* Road tanker loading/ discharge terminals * Sea tanker loading terminals
separate containers for subsequent analysis. EPIC IOIIT Portable WaslewaterSampler To MISA Specifications
* Consolidation tank feeds EPS 1030
Sludge Sampler
Circle 205 on Reader Service Card
EXCLUSIVE CANADIAN REPRESENTATIVE
CANCOPPAS LIMITED 1045 SOUTH SERVICE ROAD, OAKVILLE, ONTARIO L6L 6K3
TELEPHONE (416) 847-2740
FAX (416) 827-6984
Circle 206
ISSN-0835-605X Editor and Publisher TOM DAVEY
(416) 727-4666
June/July 1992, Vol. 5 No. 3 Issued July, 1992
CONTENTS
Associate Editor SANDRA DAVEY Sales Director STEVE DAVEY
US lab team develops risk assessment curriculum
(416) 727-4666
B.C. Sales Representative RON GANTDN (604) 274-3849 Sales Representative PENNY DAVEY (416) 727-4627 U.S. Representative AL STIVER (416) 244-5502
14
A review of home water treatment devices
Article by Brian Doherty
18
Landfill methane now generates 23 megawatts
20
EC's blue flag designates safe UK bathing beaches Report by Tom Davey
23
Technical Advisory Board Robert B. Baker, M.A.Sc., P.Eng. Totten Sims Hubicki Associates
George V. Crawford, P.Eng. Gore & Storrie Ltd.
Rod Holme, P.Eng. Proctor & Redfern Ltd.
Peter Laughton, M.Eng., P.Eng. R.V. Anderson & Associates
Allan Churcti, C.Chem.
Church & Trought Mike Provart, M.Sc., P.Eng. M.M. Dillon Ltd. Dr. Howard Goodfellow Goodfeliow Consultants Ltd.
Robert Ferguson, P.Eng. Metro Toronto Works Dept.
Value not price is vital in choosing environmental lab
25
services
Article by Tom Davey Ontario digester gas code Article by R.J. Willcocks
the debate continues
27
Purifying stormwater via a groundwater enhancement system
29
Article by John Van Egmond
34
AWWA water research is alive and well
R. Bruce Smith, LL.B.
Blake Casseis Graydon Dr. Earl Shannon, P.Eng. CH2M Hill Engineering Ltd.
Use of health risk assessment in the management of environmental liabilities
46
Article by Dave Whaley
Peter Turgoose, A.Sc.T.
New standards for testing water fittings for
Canron West Pipe (BC)
toxicity
Environmental Science & Engineering is a bi-monthly business publication published by Davcom Communications Inc. An all Canadian publication, ES&E provides au thoritative editorial coverage of Canada's municipal and Industrial environmental control systems and drinking water treat ment and distribution.
ES&E's readers include consulting engi neers, industrial plant managers and en gineers, key provincial and federal envi ronmental officials, water and waste-water treatment plant operators and contractors. ES&E welcomes editorial contributions
but does not accept any responsibility whatsoever for the safekeeping of con tributed material. Environmental Science
& Engineering, 10 Fetch Or., Aurora, Ontario, Canada, L4G 5N7, Tel: (416) 727-4666 Fax:(416)841-7271. All advertising space orders, copy, art work, film, proofs, etc. should be sent to EnvironmentalScience& Engineering,c/o Pro-Art Graphics, 70 Ferrier St. Mart^ham, Ontario, Canada, L3R 2Z5, attn: Gary Welch
Second Class Mall
Registration No. 7750 Printed in Canada, by Pro-Art Graphics Ltd. No part of this publication may be rep roduced by any means without written permission of the publisher. Yearly subscription rates: Canada $45.00 for one year, $80.00 for two years, $8.00 per single issue; cheques must accom pany subscription orders. Directory & Buyers' Guide $35.00.(G.S.T. extra)
Article by Bob Stevens
50
Waterloo recycling centre meets materiai diversion objectives
54
Conference Previews Cetech (Toronto Oct. 20-22) Aqua 92(Vancouver Sept. 9-11)
57-60
62
Development of flow measurement technology
78
Article by Peter Baker Departments Editorial Comment
4
Classifieds
Industry Update
6
Product Review
R&D News
39
52
Reader Service Card
65-74 64a
CHECK THE LABEL
Cover Story: Britain's inland waters need more mon itoring says a UK Royal Commission. The Leeds and Liverpool Canal played a significant role In the Industrial Revolution and the area was made famous by George Orwell's book. The Road to Wigan Pier. See UK report on page 76. Photo Tom Davey
If the date on the address label on the front cover
reads JUNE 92, your sub
scription has expired as of this Issue. To avoid missing the next issue, simply send
a cheque for $48.15(G.S.T. inc.)and the address label to ES&E.
Information presented in ES&E Is collected from a variety of sources presumed to be accurate and complete. ES&E cannot be held responsible for the accuracy of the information presented. Readers are encouraged to contact authors,agencies and companies directly for verification and/or clarification. Material In ES&E only conveys information and should not be considered as legal or professional advice.
Environmental Science & Engineering, July 1992
3
Editorial Comment
By Tom Davey
Will Gold's lustre be burnished or tarnished?
When Charles Darwin pub
origin.
lished his Origin of Spe cies. he posed the biggest
If Professor Gold's theory holds, there could be more gas and oil in the Pre-
challenge to conventional
thinking since Copernicus and Galileo
Cambrian Shield, which covers much of Eastern Canada, than the oil-rich Mid
postulated that our world was not the
dle East.
In 1989 the drill at Siljan indeed struck oil but only about 80 barrels was observed. "It was not coming up at a rate at which it was economically viable, but
centre of the universe.
Now a new challenger to orthodox thinking is emerging in the form of Tho mas Gold, a 71 year old multi-talented engineer who is presently a Professor Emeritus at Cornell University. He has served as a consultant to NASA,taught astronomy at Harvard and been prin cipal scientific officer at the famed Royal Greenwich Observatory in England. There are. he says, vast reserves of hydrocarbons available deep within the Earth which are not biological in origin. Conventional wisdom decrees that all
such fossil fuels were produced biolo gically. Indeed popular educational programs, as well as textbooks, unequivocably state that fossil fuels are bio logical in origin. His startling theses have often shaken the very pillars of the geology,chemistry and energy establishments. Unlike Ga
it showed there was oil down there." Professor Gold said.
In late 1991. a new drill hole was
Tom Davey
ration began in a geological formation known as the Siljan Ring where they originally planned to drill more than five kilometres deep in a search for oil or gas. The Siljan Ring is the site where an enormous meteorite impacted the Earth some 360 million years ago. The site there is believed to be similar
to the Canadian Shield. It is so old that it
lileo. he has not been threatened with
is believed no sedimentary rocks, the source of conventional hydrocarbons,
the rack unless he recants — but he has
could lie beneath it. Moreover,scientists
been subject to ridicule and the con temptuous dismissal of this theories. Professor Gold's startling theory is revolutionary. He says that most hyd
and geologists, supporting the abio
genic theory believe the impact crater could in fact be the seal of a vast reser
voir of gas or oil of non-biological
rocarbons were formed from non-bio
begun closer to the centre of the impact ring where there was even less sedimen tary rock. Small quantities of oil in the second hole were reached at a depth of about 3.8 kilometres, a depth which is still economically viable. Early in 1992. the drill hole passed the 4 kilometre mark and was still going. While still unproven. the abiogenic theory gives hope that many huge reser voirs of methane and oil could lie in
countries which are presently impover ished because they lack energy re sources.
But. if Professor Gold is wrong, a car eer rich in honors, including the 1984 Gold Medal of the Royal Astronomical Society, might turn into a scientific culde-sac. If he is correct, the implications of a world with an abundance of clean-
burning methane will have profound environmental impacts. Both the economic and environmen
logical sources buried within the earth for some 4.5 billion years. He does not deny that some hydrocarbons were
tal potential of such new energy sources could be staggering. Any massive
formed from biological sources (biogenic) in the conventionally accepted
substantially reduce acid rain. and. as
manner. However, he postulates that there are vast reserves of (abiogenic) methane available at great depths where geologists have never thought to look. Abiogenic methane might also have 'leaked" from great depths into conven tional reserves.
One petroleum geologist responded sarcastically to this thesis: "It's on the same level — and I'm not being face tious — as saying the sugar plum fairies
switchover to methane from coal would the combustion of methane releases less carbon than either oil or coal, the
May 25, 1992
Dear Mr. Davey,
I ao pleased t I convey ny waroesc congraculatioi and best wishes to you ■n receiving a 1992 Environmental Achieveaent Award in tt-
CoBDunications category.
The efforts of individuals like you, and
organizations such as Environaent, Science and Engineering Magazine, serve as a reminder that the goal of sustainable development is within our reach. You aay take great pride in your achieveaents and in the recognition you have received as a winner in the Coaaunications category. You have contributed in a significant way to protecting, vlng and rehabilitating the <
American Gas Institute and the Swe
dish Power Board,drilling for abiogenic energy began in 1986 in Sweden. Explo-
sources of methane adds a third dimen sion to his thesis.
When Martin Luther challenged the powerofRome in 1517. he nailed his95
With every good wish.
theses to the door of All Saint's Church
at Wittenberg. Now Professor Gold has confidently, and irrevocably, nailed his
will cure cancer." More recent critics
include Lloyd Snowden of the Geologi cal Survey of Canada, who says the evi dence that oil and gas are biological in origin is overwhelming. But. with the financial backing of the
greenhouse effect of carbon dioxide build-up might be somewhat mitigated. As scientists now feel CO: build-up has begun profound climatic changes with a warming trend, the possibility of new
m story on page 44.
thesis to the doors of academe for his
peers and the world to judge. The drill bit at Siljan. both metaphorically and in reality, could be a revolution which
might herald the dawn of a new energyrich Industrial Age — or tarnish a dis tinguished academic reputation.
Environmental Science & Engineering, July 1992
U-Liner'' The Proven
Solution Sewer rehabilitation with U-Liner is
both proven and cost effective. Installation is fast and simple. You get long lasting results — and you get them without ground breaking (or road breaking) technology. U-Liner is installed through existing
manholes — yet it is tough, strong and durable. Jointless, ultra-smooth results
put an end to root intrusion, leaking joints and costly back ups.
Uniform wall thickness, factory quality control and our experienced engineering mean you can rely on U-Liner to hold up the load — even in collapsing, cracked and badly deteriorated sewers. v. <v;, .
^.;.'
• 't-
,
Using TV monitored internal lateral cutting, the polyethylene U-Liner no-dig solution saves time, money, traffic and neighbourhood disruption. U-Liner sewer rehabilitation — the environmental choice.
The Pipe Within A Pipe
U-LineKPipe
aEQ, U-LINER '
TORONTO
I* **' ■*■» •
'•V- •.A'?'>^
#21 —4161 SladeviewCr.
.'•'M
i .'':^
VANCOUVER 6325 - 171 Street
Mississauga, Ontario L5L 5R3
Surrey, B.C. V3S 7K4
Tel: 416-607-0011 Fax:416-607-4463
Tel: 604-328-0300 Fax: 604-574-4563
For more information, Circle reply card No. 185
Industry update several years experience in this field. This type ofunit has been installed for a few months in the various filling cen ters of the Dehon Group in France. Bel gium. Switzerland and Spain. Each re clamation unit is made up of a distilla tion group and has storage and mix ing capacity. The distillation system removes the polluted product from the recovery cy linders(under the condition that it is not a mixture which cannot be reprocessed). Then the product is separated from the
Alliston WPCP submersible pumps running since fall of 1989
oil in a distillation tank.
Each station, dedicated to one type of refrigerant(R 12. R 22. R 502) reclaims the product which is then analysed in a laboratory in order to check sys tematically that the specifications of the product meet those required by the producer. So the product, when redistributed, always meets the original specifica tions.
Anaerobic technology The Alliston Water Pollution Control
Plant had four submersible sewage pumps, each with variable frequency, installed in its recent expansion. The Flygt submersibles were installed on the return sludge system. Two were Model CP 3127LT; each with 7 kw. 51 1/s at
8.45 m TDH.The other two pumps were Model CP 3085MT; each with 1.6 kw. 19 1/s at 4.1 m TDH. Each of the four
pumps has its own Eldurail variable fre quency drive which is tied into the main plant flow meter for automatic return
sludge flow variation. The two larger pumps have been running since the fall
Reclamation of CFCs
from New Brunswick
of 1989. The Alliston WPCP is owned and
operated by the Ontario Ministry of the Environment. Construction cost of the
expansion was approximately $9.1 mil lion and took almost two years to com plete. The 5681 m^ (1.25 MIGD) plant was commissioned in the summer of 1990. Proctor & Redfern carried out the en
vironmental study report, plant design, and construction supervision. Con struction was carried out by SutherlandSchultz of Kitchener.
to the specifications ofa brand-new pro duct. Indeed only this reclaimed pro
In France
duct will be available to maintain the
Distributors of CFCs have had to cope with new ecological requirements and consequently have set up a system of collection and CFCs.
reclamation of used
These products must be reprocessed
treats municipal and food processing waste
existing installations after the European CFC production stops in June 1997. COG AL.the engineering company of the Dehon group — a leader in distribu tion of refrigerants in Europe — has designed a reclamation unit based on
in California The City of Tulare. California, wanted "a simple, efficient, low-maintenance method of treating combined poultry/ dairy/municipal waste." when it began searching for a suitable system to add to its existing municipal wastewater treat ment plant.
Due to the expansions of the City's industrial park, and other factors, the existing treatment plant had to be up graded. A new system had to effectively treat 2.6 million gallons per day.consist ing of approximately 28% domestic wastewater and 72% dairy/poultry wastewater (Haagen-Dazs. Louis Rich. Adohr's. Kraft General Foods, Dairy men's Co-op).
After initial investigation by the City's consultant, it was concluded that anae robic treatment would be the most cost-
WATER IS OUR ONLY BUSINESS CERTIFIED WATER ANALYSIS Up to 56 parameters Water Potability Analysis
WATER TREATMENT DIVISION • Filtration Systems for iron, Manganese and Sulphur Gas removal
Bacterial Analysis Trace Metals Analysis Environmental Testing
• Softeners • Filters for drinking water • Ultra Pure Water Systems for Hospitals and Laboratories • Municipal Water Control Valves up to 16 inches
Canadian Quality Products & Services in Domestic, Industrial and Municipal Markets For Over 13 Years WHEN IT COMES TO SERVICE WE DELIVER! Enquiries Welcome, Our Booth #405 At Aqua '92 WSH LABORATORIES LTD. 3851B - 21 STREET, CALGARY, ALBERTA, CANADA T2E 6T5
TELEPHONE:(403) 250-9164, TELEFAX:(403) 291-4597 For more informatior}, Circle reply card No. 140
Environmemal Science & Engineering. July 1992
Continuous Emission
Monitoring The Westech
Westech provides a single sourcefor all your C.E.M. needs . .. •Applications Engineering •Staff Training •Systems Design
• Qualified Service
•Assembly
•Installation
'Testing
•Eabrication
•Start-up
commissioning
Whether you require a simple single component system or a complete multi-componentpackage with data acquisition and mass flow, Westech is the choicefor today's environmental needs.
Solution Measured components include: NO,N0„ NOx,S0„ Hfl, TPS,HCl, HE,HCN, Cf C10„ CO,, CO,0„ THC,VOC,Opacity and MassElow. Whatevertheproblem,Westech has the experience and the equipment to provide the solution.
Westech has been Canada's
leading packager of Analytical Systems for Process and Environmental Measurement in
air and waterfor 25 years.
t
HALIFAX
MONTREAL
TORONTO
SARNIA
REGINA
CALGARV
EDMONTON
VANCOUVER
TEL:(902)865-5486
TEL:(514)367-4036
TEL:(416) 890-5265
TEL:(519) 383-6320
TEL:(306) 757-5006
TEL.;(403) 252-8803
TEL:(403)464-4740
TEL:(604) 278-5112
FAX:(902)865-2157
FAX:(514) 631-0857
FAX:(416)890-6213
FAX:(519)383-6322
FAX:(306) 757-2205
FAX:(403) 253-6803
FAX:(403) 467-1605
FAX:(604) 278-5126
For more information, Circle reply card No. 141
Environmental Science & Engineering. July 1992
Industry update effective means of handling the increased loading and meeting effluent limits. Pilottestingofseveral systems indicated that the ADI-BVF® technology engin eered by ADIfrom Fredericton,NB would be the best choice for the City's needs. As a result, the City proceeded with instal lation of a full-scale BVF™ system. The BVF reactor is a 31 million gallon lined basin in which the organic matter in the wastewater is converted into bio-
gas and other end products. The reactor is covered with a floating, flexible, in sulated membrane cover which pre vents escape of odors and allows for collection and use of biogas. Sometime in 1992 a portion of the biogas will be burned in a 450 kw engine-driven ge nerator. It will supply the electrical
energy needs of the entire (municipal and industrial) waste treatment facili ties.
The system is providing BOD remov als of over 90 percent. The reactor is designed to handle up to 4.4 million gallons per day(at a COD of3700 mg/1). in anticipation of future industrial park expansions. The anaerobic system ef fluent is discharged into two aeration basins and four waste stabilization
ponds for polishing, and finally crop irrigation. Due to the large sludge storage capa-
MacViro recently held a successful 'beat the recession' reception at Its head office. Shown left to right are Sid Glllespie, President of MacViro Consultants, Jill Almond, P.Eng.,Assistant Project Manager, Marathon Realty,Howard Shrlmpton,P.Eng.,Vice
President of MacVIro, Nick Vardin, P. Eng., Commissioner of Public Works and the Environment, City of Toronto. Photo Tom Davey
city of the ADI-BVF reactor, sludge wasting is not anticipated for several years.
ADI provided all engineering ser vices. from pilot plant study through facility commissioning and start-up. in cluding design, development of specifi
cations and drawings, construction supervision, and production of a pro cess operating manual. The system was installed in 1989 for a cost of approximately S5 million, while the co-gen unit was added in 1991 at a cost of $1 million. ES&E
Letter to the Editor Dear Tom.
ROBERT B. SOMERVniEoo- mc.
Our corporate announcement in the February/March 1992 issue of your ma gazine went across very smoothly and leads us to believe that we have made the
correct decisions with respect to style and message to stimulate thought and comment on our activities. We have had
feedback from as far away as the Maritimes that our professional colleagues have noticed and commented on the announcement. Our friends closer to
home have also done so in great
We Go Under
numbers. The feedback reminds us that we have
many friends out there who wish us well.
It has also paved the way to some extent to the formation of some new friend
Major Hlgh"ways^
Conservation Areas
'Landfills
ships. Please accept our thanks for your
Rivers
input and advice on the development of what we consider to be a bold announ cement.One that has been so successful
Waste Sites
in its effect in carrying the message of our business launch.
For A Trenchless Environment '^Directional Drill" Canada — CAM TYHURST Phone: 519-776-8727 Fax: 519-776-6616
Thank you for your encouragement and good advice on these matters and for the other enjoyable philosophical
US. — FRED BRITT Phone: 903-784-0866 Fax: 903-784-2995
discussions we have shared.
H.A. Barran, P.Eng., M.B.A. Manager, Engineering Hardat A. Barran Engineering Inc.
For more iriformation, Circle reply card No. 186
Environmental Science d Engmeering, July 1992
A talented pair of English feet were the first to sprint over the "Impenetrable Physiological
Fill in your answer on the coupon below, and we'll send you our color ful "MSU 12 Foot Wall Poster"
Featuring The Worlds Greatest Feats. Even if you don't get the
Barrier." He ran the mile in under
4 minutes(3 min. 59.4 seconds) on
May 6, 1954? Whose now famous feet were they, anyway?
correct answer.
World Famous Feats Up for Grabs. Sometimes the hands are faster than the feet. MSU provides hands on security at the leading end of an upward or downward climb. Our entry and exit ladders are carefully crafted for maximizing strength and safety.
We design and manufacturer our own off-theshelf, wide range of corrosion resistant Safety Steps, Ladders, Platforms, Guard Rails, Manhole Grates. We also custom design and fabricate spe cial safety equipment to match your specific applications. MSU products provide maximum security and safety for climbing or descending... whether outside a tower, chimney or inside a shaft. We're into safetyfeetfirst.
#1114, MSU Entry and Exit Ladder with
extended, widened
freestanding supports. Use in
applications
Those are the Famous Feet of:
that do
not permit
Please rush me your "MSU Wall of Fame Poster" Featuring
attachment
12 of the Worlds Greatest Feats.
to roofs
#1112.. MSU Entry and Exit Ladder
with extended,
widened supports for easy access.
Boll -on designfor chimneys, roofs, silos and tanks.
MSU Mississauga Ltd. 2222 South Sheridan Way, Mississauga Ontario L5J 2M4 (416) 823-4340 Fax (416)823-4947
Name: Title:
Company: Address::
City:
Province/State:
Postal Code:
MSU Mississauga Ltd. 2222 South Sheridan Way, Mississauga, Ontario Canada L5J 2M4 MSU 2R MINUTE JB90
For more information,
Circle reply card No. 116
Industry Update Telecom funds two
Ontario air quality showed slight improvement in 1990 The number of ozone incidents des-
creased slightly during 1990 according to a report on air quality in Ontario re leased by the Ministry of the Environ ment. In 1990, there were 13 days where ozone levels exceeded the provincial air quality criteria of 80 parts per billion, down from 36 and 18 such days for 1988 and 1989 respectively. The report also states that undesir able air quality levels were reached on a
grad student projects Mark O'Neill, a doctoral student at Car-
drocarbons, nitrogen dioxide and ozone. In the early 1980s, there was an improvement for carbon monoxide and total reduced sulphur emissions, but in the last eight years average carbon mon oxide levels have remained constant.
In spite of a slight improvement, ground level ozone guidelines were ex
ceeded more often than the guideline of any other air pollutant in Ontario dur ing 1990. While naturally occurring number ofoccasions and that moderate ozone in the stratosphere is beneficial to to poor air quality was recorded for at life by shielding the earth from harmful
ultra-violet(U.V.)radiation given off by the sun. high concentrations ofozone at include such contaminants as ozone, ground level are a major health and en suspended solids, sulphur dioxide,total vironmental concern. At ground level, reduced sulphur, nitrogen dioxide and ozone, a component of smog, is injuri ous to species of vegetation and can hydrocarbons. According to the report, ambient air cause eye and lung irritation. The Ontario routine air monitoring quality in Metro Toronto was worse least one hour at all Air Quality Index
sites. The provincial air quality criteria
leton University, is studying the use of carbon dioxide in a supercritical state as a way of removing toxic substances from plastics. Judith Schneider, can didate for a master's degree in biology at the University of Ottawa, is looking at the impact of a commonly-used her bicide on aquatic life. Both are the first recipients of Environmental Research Scholarships offered by Telecom Canada.
Mr. O'Neill thinks supercritical car bon dioxide may be a very effective way
of removing toxic substances within plastics as well as the residue of those they may contain,e.g. plastic containers for pesticides. Carbon dioxide is super critical when it is above its critical tem
that in Montreal, Vancouver. Boston,
network has a total of 418 instruments:
perature and pressure. In this state it is a very dense gas that can penetrate solids, such as polymers, which are composed of densely-packed fibers. Supercritical
Atlanta and Chicago for the most recent comparable year, 1989. This was based on a system where each city was ranked according to five individual criterion contaminants (carbon monoxide, nit rogen dioxide, ozone, sulphur dioxide, total suspended particulates) using all the data measured in the monitoring networks in each metropolitan area. Ten-year trends show a slight im provement for sulphur dioxide, total suspended particulate levels and a sig nificant improvement in lead levels but little change in suspended particles, hy
279 continuous monitors and 139 hi-
carbon dioxide will make contact with
volume particulate samplers. Out of 48
the toxic chemicals within the fibers as
ozone stations, 45 recorded at least one
well as those adhering to them.
Bacteria-based biosensor â&#x20AC;&#x201D; better than fish? British researchers are developing a bio sensor that may detect a wider range of pollutants than present systems using fish. It will be able to monitor intakes at water treatment works.
The Water Research Centre (WRc),
Luton College of Higher Education and the Cranfield Institute of Technology claim to have developed a system that is cheaper,simpler and easier to maintain than conventional systems. The bac teria Synechococcus is immobilised bet ween inorganic filters on an electrode. The electrode is placed in a flow of water
occasion where the one-hour Air Qua
lity Index for ozone was exceeded. For suspended particles, 25 out of the 43 stations recorded levels of suspended particles in excess of the 24-hour cri terion.Copies ofthe rt-porUAir Quality in through the ministry's Public Informa tion Centre, at 135 St. Clair Ave. West.
able.
Ontario â&#x20AC;&#x201D;1990,PIBS 1804,are available
Toronto. Ontario. M4V 1P5,(416) 3234321.
current which can be monitored by
Ms. Schneider is examining the ef fects of a herbicide used extensively by
the forestry industry to prepare refores tation sites, and by utilities to control weeds on rights-of-way in wooded areas.
computer.
But after rainfalls, the herbicide may be
Any pollutant disrupting the meta bolic processes produces a measureable
carried by surface and underground
reduction in the electric current.
She says previous research has shown
water run-off into nearby waterways.
The scientists believe that the system
that the herbicide will kill off much of
will be more responsive to pesticides and herbicides. A field prototype will be available by the end of 1991. The WRc team is now ready to design a biosensor
the algae in streams and rivers, thereby reducing the number ofinsects that feed on it. To measure more precisely the
to monitor wastewater.
extent of this adverse effect,she plans to construct two sets of artificial channels in a stream. Into the different channels
VP Elected
in one set she will put varying concen
John F. Gartner, P.Eng., President of Gartner Lee Limited and a Consulting Engineering Geologist has been elected
trations of herbicide. The other control set will remain untouched.
Vice President of the Canadian Geos-
chemical mediator, potassium ferricyanide, are added to the water to activate
Mines and Resources National Indus
the bacteria and electrons produced by their metabolic processes are trans ferred from the mediator to the elec
trial Advisory Committee to the Geolo gical Survey of Canada. The Survey is celebrating its 150th Anniversary this
trode. This generates a small electric
year.
10
tract toxic substances from sand but
very little such work has been done on plastics. He favours carbon dioxide in its supercritical state because it is nontoxic. inexpensive, and readily-avail-
cience Council.This Council represents some 16.000 geoscientists in Canada.In addition, he was recently appointed Chairman of the Minister of Energy
drawn from the intake. A nutrient and
He says there has been some research on the use of supercritical fluids to ex
By comparing the diversity of insects, their number and size before and after the treatment. Schneider will determine
changes and consequently,any harmful effects the herbicide may have pro duced. Telecom
Canada
established
the
$2500 annual scholarships, one each at Ottawa's two universities,in 1991 as part of its 60th Anniversary celebration.
Environmental Science & Engineering. July 1992
Industry Update Pipe Association
leyfield. Quebec was elected Chairman of the Board. Wilf Gray, Concrete Pipe Company of Mississauga. Ontario is
formed
Vice-Chairman and Bob Wood. Con
Canadian Concrete
A group of some 30 producers of con crete pipe, and suppliers of materials has formed the Canadian Concrete
Pipe Association with its head office in Toronto. At the present time Quebec and Ontario concrete pipe producers have provincial associations (Tubecon in Quebec and QCPA in Qntario).
Those two groups are now affiliated to the new organization that will also
cond general meeting to be held in Quebec next June.
members are elected for a two year
Chairman Tache says"that coordina tion of research and development, pro motion. education and government re lations pertaining to the marketing of high quality precast concrete was
term.
tewater and storm drainage products in
Several proposals for possible course of action were formulated by the mem bership for immediate consideration by the Board of Directors who. after study, will submit an action program at a se
Canada, will be of benefit to. and in the best interest of all concerned" — the
Cast Pipe. Guelph. Ontario is Secretary Treasurer. All three executive board
industry,the specifiers,the builder(con tractor) and the general public". continued overleaf
maintain close contacts with its Ameri
can counterpart, the American Con crete Pipe Association.
The Board of Directors is composed of representatives from the Maritime pro
AT YOUR SERVICE FOR 20 YEARS
vinces. Quebec. Qntario. the Western
provinces and two representatives from the suppliers associate group. Gilles Tache. Brunet Concrete Products ofVal-
Calgary Conference The 44th Annual Conference of the Western Canada Water and Wastewater
Association
and
the
Annual Con
The first Canadian made complete portable open channel flow monitoring system.
ference of the Alberta Chapter. Cana dian Public Works Association will take
Infiltration & Inflow
place at the Westin Hotel. Calgary, Al berta. Tuesday. October 13. 1992 to Fri day. October 16. 1992.
studies
Overflow studies David Suzuki,the TV personality and environmental scientist will give the Keynote Address, "Our Environment: New Challenges and New Technolo gies."
Sewer System evaluations
Monitoring of industrial
Learn what's new at Western Cana
da's biggest industry conference and exhibition. Municipal Expo '92 will be held at the Stampede Grounds at the same time and you can see hundreds of exhibits by suppliers and manufac turers of water, wastewater and public works equipment. Contact Gordon Smith(403)261-6965 or WCWWA Office (403).259-4041.
discharges
WE HAVE WHAT YOU NEED: • Water quality kits • pH meters • Water level indicators
• Portable gas chromatographs • Reverse osmosis system • Laboratory & field equipment
• Water and wastewater samplers
Contract Chemist Available
PLEASE ASK FOR OUR CATALOG
Ph.D./C.Chem. available for short
term assignments/small projects. Site Assessment, Monitoring/Samp ling & Analysis, Certificates of Appro val, Site Health & Safety Plan, Con tingency Plan, Lab. Packing, Canada and US EPA Regulations. Detailed resume on request: P.O. Box 701, Stn. B, North York, On tario, M2K 2P9, Fax (416) 3673476.
Environmental Science <S: Engineering, July 1992
GENEQ inc. 223 SIGNET DRIVE, TORONTO, ONTARIO, CANADA M9L 1VI TEL:(416) 747-9889 FAX:(416)747-7570 8047 JARRY E., MONTREAL, QUEBEC,CANADA H1J 1 MS TEL:(514) 354-2511 FAX:(514) 354-6948
For more information, Circie repiy card No. 117 11
Industry Update tions contractor for the space centre,
Cement Industry Tackles Waste Management At a Symposium entitled Cement Industry Solutions to Waste Management, engin eers and scientists from fifteen countries
will discuss current practices and new technologies in waste disposal. The Symposium will be held at the Conven tion Centre in Calgary. Alberta,October 7, 8&9, 1992.
The meeting will focus on the mul titude of ways that portland cement and concrete can be used to recycle, encap
sulate,stabilize or destroy a wide variety of industrial and domestic waste pro ducts. A special session will be devoted to energy and resource recovery from certain types of waste in the high tem peratures ofthe cement kiln,the key ele ment in the cement manufacturing process.
Dealing with the disposal of a broad range of waste products,from domestic garbage to hazardous industrial sludges, has become a major challenge for both the public and private sectors in Canada, and other countries. Portland cement
can be used to chemically or physically alter specific wastes to allow safe land filling. Concrete can be used for encap sulation or containment of waste to pro vide safe storage. Concrete has been
Solarchem cleans up space shuttle launches Solarchem Environmental Systems Inc. ofRichmond Hill,Ont.recently beat out three U.S.competitors to supply a clean up system for waste water created at the National Aeronautics and Space Ad ministration's Kennedy Space Center in Florida.
Solarchem's Rayox® system will treat
announced that Solarchem won the
$231,465 (U.S.) contract. The system will be built in Richmond Hill and should be delivered by Novem
sprayed over large volume wastes as a shield to reduce leachates to acceptable levels. These and several other topics will be addressed by symposium speakers. Organic wastes such as used tires, domestic garbage and waste petroleum products all contain potential energy that can be used as a partial fuel replace ment in the portland cement manufac turing process. Selected inorganic wastes can be recycled as raw feed for cement manufacturing. Speakers at the Sym posium will present cases where these processes are an integral part of the day to day cement manufacturing process. New research that is ongoing to find more and better ways to dispose of waste will also be presented. The Symposium is sponsored by the
ber.
Call for papers for PCA01993conference The Pollution Control Association of
Ontario will be hosting its Annual Con ference from April 4-7. 1993 at the Regal Constellation in Toronto.
A strong Technical Program is planned, encompassing diverse aspects of pollu tion prevention and control, including topics covering academic, legal, muni cipal and industrial fields. These will be held in conjunction with a large equip ment exhibit and an Operations" Challenge. Those interested in presenting a paper or poster on behalfof your organization, please FAX a one page abstract to the PCAO office at(416)502-1786,attention Mrs.Sandy Pickett. Abstracts should be received by September 30. 1992.
Canadian Portland Cement Associa
tion, representing the Canadian portland cement manufacturing industry. For more information,contact: Robert
W. Piggott P.Eng., Regional Director, Canadian Portland Cement Associa
tion, 201-1155 West Pender Street, Van couver, British Columbia V6E 2P4.
New directory gives
Phone: (604) 685-0582, Fax: (604) 6851574.
envlro-contacts Entries range from abandoned mines to zoo associations. They include govern ment departments — federal to munici pal — the acts they administer and the programs they run with all the contact
the water used to clean the launch pad of spent rocket fuel and other toxic che micals formed in combustion following each space shuttle launch. The system destroys toxic contaminents in the water by using ultra violet light to create hydroxyl radicals. These are atmospheric scavengers with an appetite for electrons and willing to break up toxic compounds to get them. EG&G Florida Inc., the base opera
names and numbers. There are sections
on research labs, university programs, conferences and resource books. Any one sourcing environmental products or services will find over 5,600 listings all classified and cross-referenced by sub-
Groundwater Control For Both Worlds Griffln provides services for your groundwater or remediation problem tti
CLEAN
Construction Dewatering • Recharging Eductor Systems Wellpolnts Slurry Walls Deep Wells MAC Hydraulic Sewage Bypass Submersible Pumps Open Pumping
99
fS
DIRTY
• Recovery Wells • Vapour Extraction • Remedial Dewatering • Biological Treatment • Air Stripping
• Carbon Treatment • In Situ Treatment
• Slurry Trenches • Landfill Gas Venting • Sludge Handling
GRS
IT.
GRIFFIN
Griffin Groundwater Control Services
GrifTin Kemediatiofi Services
Guelph, Ontario, 1-519-763-9400
For more information, Circle reply card No. 118 12
Environmental Science <& Engineering. July 1992
Industry Update ject or category of use. And for help with regulations and compliance there is a directory of lawyers practicing environ
Summa to represent Great Lakes Instruments in Eastern Canada
mental law.
The Canadian Environmental Direc
tory also provides statistics on our na tional performance, overview essays on critical issues and a chronology of events of the past year. $175. Canadian Almanac & Directory Publishing Co. Ltd. (416) 362-4088 Fax: 362-4181.
For more Information
Great Lakes Instruments have appoin ted Summa Engineering Limited to sell its product line. As GLLs Canadian re presentative east of Manitoba, Summa will be selling the complete product line with the exception oflevel instrumenta tion and the Zullig Dissolved Oxygen James D. Burke, GLLs International
services described in this
Sales Manager, said the company is confident that Summa's engineering expertise will help serve clients" process
issue, use the
Solutions fofi Down-to-Earth< Problems
Sensor.
on any of the products or
Reader Service card.
High-Tech i
Soil Soil Augers/Core Samplers/ Soil Recovery Augers
needs. Details from Summa; Phone
Good for any type ofsoil sampling,
(416)624-3188 Fax:(416) 624-1293.
disturbed or undisturbed.
Water CITY PRICES
TONIOHT'S WEATHER;THUNDERY
Ground Water
EveningStandard LONDON,TUESDAY, JUNE, 1992
The hi-tech tennis rackets BULIMIA
are ruining the game ||
nOE OF ANGER AT WATER BILLS Complaints up 130% as chiefs' pay soars by Tony Maguire ANGRY home-owners bombarded the
water industry watchdog with a
record mountain of complaints last
Sampling Vehicle A self-contained truck or trailer mounted
method of purging wells or extracting ground water samples.
Port-a-Reels Manual or hydraulically-operated portabili ty for purging wells and extracting samples.
Discrete Liquid Sampler Sample below the surface ofliquids at any predetermined depth or pull a series of samples from various depthsfor a composite sample.
New Dual Valve Liquid Sampler Recover samples from the bottom of any container or ground water wells to check for contaminants heavier than water,
including hydrocarbons.
Thames — that he will not tolerate "excessive" returns to
shareholders because their money is locked into a cast iron
year as big water bills followed hard hivestmenl. The water firms are gradually changing their attitude to on bumper pay rises for the men at the their customers,althou^ according to Mr Byatt, there was
top.
still a long way to go. Ian Byatt, director general of the watchdog Ofwat. re However, be pointed out that many customers did not vealed today that complaints leapt by 130 per cent — to fuUy understand that water firms ntntded big profits to help
10.S3S. The vast majority were about Ui price of water,
them maintain the investment needed to provide pure Mr Byatt warned the water firros — led by Roy Warts's drinking water and clean rivers.
Privatized UK Water Boards hit the headlines in June with complaints up 130%. Angry home-owners bombarded the water industry watchdog with a record number of complaints last year as big water bills followed hard on bumper pay rises for the top executives. Ian Byatt. director general of the watchdog Ofwat. revealed in a June "92. report that complaints leapt by 130 percent — to 10,635. The vast majority were about the price of water. He warned the water firms that he will not tolerate "excessive"" returns to share
holders because their money is locked into a cast iron investment. However,he pointed out that many customers did not fully understand that water firms needed big profits to help them maintain the investment needed to provide pure drinking water and clean rivers. Many customers criticise the profits made by water companies and complain about large price increases. It is important that the companies should be profitable otherwise investors will not provide the funds essential for the completion ofthe £28 billion investment program.(Approximately $60 billion). More than 70 per cent of water firms" profits are reinvested. Although share holders need a return on investment, he said,"this should not be excessive given the low risk nature of the industry."" Mr. Byatt warned he will review the water industry"s prices in 1994. TD
Gas Soil Gas Vapor Probes/ Dedicated Vapor Points Monitor underground storage tanks.
Retract-A-Iip Pre-site investigations for soil gasorfor tracking vapor plumes.
We specialize in custom
design applications to meet your specific needs.
Swjce 1942 Art's Manufacturing & Supply 105 Harrison
American Falls, ID 83211
1-800-635-7330 For more information,
Circle reply card No. 119
Environmental Science d Engineering. July 1992
13
us lab team develops risk assessment curriculum Fellow scientist John Knezovich, an environmental chemist and tox-
icologist, said the curriculum does not attempt to answer the question of how much is enough. Rather, the course is designed to give decision makers the skills necessary to gather facts on a caseby-case basis. Varied Skills Because each environmental inci
dent is unique, the model curriculum focuses on the scientific principles and procedures used to develop a realistic method for assessing potential health and environmental risks posed by Individuals assessing risk must examine a multitude of parameters, including, dis tance from the water table, type of waste and the probability of it reaching the popula tion. Photo by S. Davey
You're a city of icial who's dis
covered that an underground tank at a gas station has been leaking solvent into the soil for more than 10 years.Yourjob is to assess the risk to residents and draft a cleanup plan. You could make your recommen dations based on generic data found in handbooks,perhaps issued by a regula tory agency several years ago. Or, you could rely on specific data on the effects of the solvent on humans, the charac teristics of the soil in your area and the
most modern technology available for cleanup.
Assessing risk Five scientists at Lawrence Livermore
National Laboratory have taken on the job of providing tomorrow's decision makers with the knowledge and the tools to make more realistic assessments of risk to humans and the environment
from chemicals leaked, spilled or re leased into the soil, the water or the air.
The scientists, all specialists in envi ronmental sciences, have developed a model curriculum,"Realistic Methodsfor Risk Assessment." It is currently being taught at the UCLA's School of Engin eering and Applied Science.The course, which attracted 25 students this quarter, will be taught soon at Stanford Univer sity and the University of California, Davis.
Environmental sciences leader Lynn
Anspaugh said development of the model risk assessment curriculum will
be integrated into the new Risk Science Program to oe directed jointly by the 14
Lab and UC Davis at the Davis campus. Part of the funding for this effort comes from the Lab.
Risk assessment is not an easy job and debate continues to rage,even in the scientific community, over acceptable levels of exposure — if any — to chemi cals and radioactive elements.
chemicals.
The decision on how best to respond to an incident can be made only after all the facts are determined, Knezovich said.
Tom McKone, who brings his back ground in engineering and chemistry to the group, said there are no actuarial tables for assessing risks to the public from exposure to low concentrations of chemical substances in the environ ment.
So many complex mechanisms are
Bruce Ames, a noted cancer expert speaking at the Laboratory recently, said that many"religious-like" efforts to eliminate traces of synthetic chemicals that are carcinogens in water,food pro ducts and hazardous waste ignore the
involved — human metabolism, for
example — that it is impossible to build a generic model that will apply across the board, McKone added. Each of the members of the scientific
fact that the world is filled with natural
team is responsible for those portions of the curriculum falling into his area of
substances, half of which also cause
expertise.
cancer in high-dose tests with rodents. What's acceptable? According to Lab scientist Jeff Daniels, no one argues over the effect of a high dose ofa systemic poison,such as cyanide. The individual taking the poi son will probably die. On the other hand, if the poison is dumped into a landfill, the individual assessing risk must look at a number of things: the permeability of the ground, the dump's distance from a water table, the changes in the poison over time and distance, and the probability of its reaching a human being or the food chain and in what minute concentra tions.
Then comes the tough question, ac cording to Daniels, who holds environ mental science and engineering de grees: What minute fraction of what's left, taken in over what period of time constitutes an acceptable level of ex posure?
Knezovich, for example, deals with the fate ofchemicals in the environment as well as looks at risk assessment as a
tool for evaluating ecosystem impacts. Daniels deals with dose-response mod els and McKone researches human ex
posure through multiple pathways and the characteristics of air, water and soil as isolated media.
Anspaugh looks at the transport and fate of radionuclides as well as the dose, health effects and risk of radioactive
material in the environment. David Layton, the fifth member of the team, uti lizes his background in water re sources.
Lawrence Livermore National La
boratory, managed by the University of California for the U.S. Department of Energy,conducts research and develop ment important to national goals, in cluding national defense. Current re search programs include weapons, energy, biomedicine and the environ ment.
Environmental Science & Engineering, July 1992
rsj
>c
D
EZ>
Technitrol•Eco Inc.
CALGARY ENVIRONMENTAL
Environmental Consultants,
Laboratory Analysis & Industrial Expertise
TRADESHOW AND CONFERENCE Formerly Haztech Canada
since 1963
OCTOBER 20 & 21,1992 Convention Centre, Calgary, Alberta
MONTREAL•TORONTO • VANCOUVER
EXHieiTS
Environmental Audits
UST Removal
Impact Studies
Operational Permits Industrial Hygiene
Risk Assessment
Decommissioning Plant Compliance
Air Quality Emissions Monitoring Toxicity Testing Hydrogeology Failure Analysis
Audits
Accredited Laboratories
Waste Management
Sampling & Analysis Site Characterization
WOFlKSHOF>S
Get your share of the sales action, book your exhibit space today! Caii:
EDMONTON
(403) 258-0705 FAX 253-5750
Managed and Produced by
s
CANADIAN EXHIBITION MANAGEMENT INC. For more information, Circle reply card No. 121
For more information, Circle reply card No. 120
International Symposium
ENVIRONMENTAL
"Cement Industry Solutions to Waste Management" Sponsored by: Canadian Portland Cement Association Location: Calgary Convention Centre, Calgary, AB When:
October 7-9, 1992
Fee:
$395(Can) until Sept. 15, 1992 $450(Can) after Sept. 15, 1992
(403) 469-2400 FAX 469-1398
CALGARY
121 Hymus Blvd. Pointe Claire, Quebec H9R 1E6 Phone:(514)697-3273 Fax:(514)697-2090
m
CONFERENCE
AUDITING
HATCH
ENVIRONMENTAL PROTECTION SERVICES
Hatch has performed audits in a variety of industries to assess the environmentai status of a facuity and/ or site.
For information & registration forms, contact: Robert Piggott,P.Eng., Regional Director
Services offered inciude:
Canadian Portland Cement Association 201-1155 West Pender St.
Vancouver, British Columbia V6E 2P4 Telephone:(604)685-0582 FAX:(604)685-1574
The meeting will focus on the multitude of ways that portland cement and concrete can be used to recycle, stabilize or destroy a wide variety of industrial and domestic waste products. A special session will be dovoted to energy and resource recovery from certain types of waste in the high temperatures of the cement kiln. Dealing with the disposal of waste products, from domestic garbage to hazardous industrial sludges, has become a major challenge for both the public and private sectors in Canada,and other countries.Pordand cement can be used to chemically or physically alter specific wastes to allow safe land filling. Concrete can be used for encapsulation or containment of waste to provide safe storage. Concrete has been sprayed over large volume wastes as a shield to reduce leachates to acceptable levels. These and several other topics will be addressed.
■ Environmental Regulatory Compliance Audits m Environmental Liability Assessments
m Occupational Health & Safety Audits m
Waste ivilnlmlzatlon Audits
■ Environmental Management System Audits ■ Integrated Audits For more information piease contact: Hatch Associates Ltd.
2800 Speakman Drive Mississauga, Ontario L5K 2R7
Tei: (416) 855-7600
Fax: (416) 855-8270
For more information. Circle reply card No. 122 For more information. Circle reply card No. 123
Environmental Science & Engineering, July 1992
15
Worker Safety
Apricot paste causes fatal explosion
Worker safety is a primary goal of the industrial hygiene profession. Oc
casionally, we contribute to the body of knowledge related to
worker safety by determining the cause of unusual accidents after the fact. One
Clayton was supplied with samples of the apricot paste from the exploded drum and asked to determine what had
caused the drum to explode so violently. Our initial speculation was that a fer mentation process had produced high levels ofethanol. However,gas chroma-
such unusual, and unfortunately fatal, accident occurred in Windsor. Ontario.
Clayton Environmental Consultants" Windsor laboratory was consulted to
Slnce acids will react with
help determine the cause of the acci
metal, the paste should have been stored in a plastic or plastlc-llned drum according to Its material safety
dent.
A worker was opening several old steel drums known to contain an apri cot concentrate paste used to produce a juice blend. The drums were over five years old and the contents were to be dis posed of. The worker assigned to open
data sheet.
the drums found that the normal drum
opener would not work because the lids were deformed. He then tried a torch to
open the drums. While the worker was using the torch, a flash from one of the
tographic analysis of the residual paste in the drum's headspace showed no evi dence of fermentation. This fact was
drums occurred. He moved the drum, added some water, and used a hand
confirmed by another laboratory at a
grinder to cut the top off the drum.Dur ing this process,the drum exploded and
yzed the same paste. The apricot paste had a pH of3.5 indi cating that it was very acidic. Since acids
killed the worker.
large Canadian brewery which anal
Reader Feedback on Worker Safety Dear Tom, Your article on Charles Dickens'con
tribution to the early environmental movement(a great writer was felled by an early Punch â&#x20AC;&#x201D; Feb/Mar '92) was a fascinating piece. As you point out, had this article been published the environ mental movement may have started a century earlier. Your comments remin ded me ofsome ofthe early history ofthe chemical industry in my own home town Widnes in England where I got my firstjob as a laboratory technician in the mid-1950's. Even then the pollution was pretty grim since most of the chemical companies payed little attention to air quality. A century earlier, Widnes had been the largest chemical manufacturing town in the world and the air pollution was so bad that it was claimed that there
were very few days when it was possible to see the sun (the sun doesn't shine often in Widnes, anyway!). Apart from the general pollution of the environ ment, workers in the plants faced enor mously high levels of exposure to toxic chemicals.
the steel drum.
Some of the paste was placed in a small glass vessel with steel wool and heated in an oven to 60 degrees to ac
celerate any reaction. After 24 hours of this treatment, gas chromatographic analysis ofthe vapor in the headspace of the glass vessel showed a hydrogen gas content of over 90 percent. The paste was very thick, and during the period in the oven, pockets of gas had formed in the paste. The reaction of the paste with iron was confirmed by analyzing the residual paste from the explosion for its iron content. The analysis confirmed the presence of iron in the paste. Com mercial apricotjam purchased from the local supermarket and used as a control had no detectable quantity of iron. Based on the concentration of iron in
evidenced by the large number of dis carded bread crusts that littered the
plant. This situation was first brought to light at one of the earliest Government enquiries into industrial working con ditions. However, when some of the
workers were called upon to testify at the hearing, they had absolutely no com plaints about their working conditions.
In fact they were convinced that the ex posure to the acid fumes protected them against the much greater scourge of tuberculosis! It would also seem that even from the
earliest days ofthe industrial revolution, workers have been acutely aware of the health and safety hazards that they faced. However, due to social or eco
nomic conditions they usually had no other choices.I think it is important that journals such as yours attempt to bring some sense of realism into the environ
mental debate.To this end,the historical
perspective is important since it con firms that we have achieved major im provements in environmental quality. Keep up the good work.
In the muriatic acid (hydrochloric) Bernard Fleet Ph.D. plant the level of corrosive acid fuijies (Dr. Fleet is president of TRSI. Pro was so great that the workers there ra fessor at the University of Toronto, and pidly lost most of their teeth. This was an ES&E contributor.) 16
will react with metal, the paste should have been stored in a plastic or plasticlined drum according to its material safety data sheet. The initial reason for not using the apricot paste was that the paste had been shipped to our client in a steel drum in which the lining had eroded. A suggestion by one of the che mists with a food processing back ground led to the hypothesis that the explosion might have been caused by hydrogen gas produced by the reaction of the acidic apricot paste with iron in
the paste and the amount of paste in the drum, it was estimated that at least one
mole of hydrogen gas was present in the drum at the time of the explosion. The initial flame observed could have been
hydrogen gas trapped in a pocket at the top of the drum. The hydrogen gas may have been above the upper explosive limit due to the lack of air in the drum
headspace. After the drum was left open for a few minutes and air had diffused in
(and hydrogen gas diffused out), the concentration of hydrogen in the headspace was in the explosive range and sparks from the hand grinder set off the explosion. A subsequent coroner's inquest ac cepted and made recommendations based on these findings. The informa tion from Clayton Environmental Con sultants" accident investigation and the subsequent recommendations should help minimize such accidents in the
future. ES&E qi^qIq ^gpiy
i\Iq 256
For more information
on any of the products or services described in this
issue, use the Reader Service card.
Environmental Science & Engineering. July 1992
R.F. Calibration 'W'
Now You Can Avoid IVIovind Thousands Of Gallons
By Barely Moving A Finger. Now Thars A Switch!
need be entered. The push
Pumping thousands of gallons of process media in and out Capacitance switch takes time,
up to 8 relay control points, including lead/lag pump sequencing. In fact, the Sentinel can be pre-calibrated
The only thing easier than using the Sentinel is calling Magnetrol
effort, and may even be hazardous. With Magnetrol's
before installation so that no
for a free demonstration.
level change is required!
Call(416)678-2720 today.
of a tank to calibrate an R.F.
button user interface calibrates
protection against dangerous and expensive spills. Free Demonstration
new SentinelÂŽ Point Level
Swftch, this problem has been Virtually eliminated.
Simpllflfid Calibration Thanks to iagneCai, a microprocessorbased procedure, the Sentinel simplifies ^ .calibration so only two probe point= (one smai',e\oi change) '
Powerful Sell-Diagnostics The same electronics that
make the Sentinel easy to calibrate also make it safer.
-
Self-diagnostic circuitry checks the entire systemâ&#x20AC;&#x201D;including the integrity of the probeâ&#x20AC;&#x201D; every 10 seconds. This not
only saves time on routine maintenance checks, it provides an extra measure of
Magnetiol The complete levei specialist
msm
i i;
Water supply management
A Review of In-Home Water Treatment Devices semi-permeable membrane which al lows water and small organic molecules to pass but traps larger molecules, such as salt and heavy metals. As with the car
drink
bon filters, the filter membrane must be
changed on a regular basis as it even tually will become clogged. Most reverse osmosis units include a sediment filter
and a carbon filter to remove organic material, so these filters must also be
changed on a regular basis. Reverse os mosis filters are very effective at remov ing heavy metals such as lead, alumi num and other trace metals. They will also soften the water to a certain extent
but very hard water will tend to clog the membrane. Reverse osmosis units de
pend very heavily on water pressure to function correctly. Although the mini mum operating pressure for these units is 40 PSl, the higher the pressure, the more effective the unit will be. Most
Public mistrust of municipal water supplies tias led to a boom in the bottled water industry. Potable water vending machines are common in parts of Florida.
home reverse osmosis units are very slow and will only produce up to one litre of water per hour,while the smaller units may take several hours to produce
Photo: Steve Davey
a litre of water. For this reason, most
Every so often Municipal water
removing a large percentage of odours, chlorine,THMs,organic chemicals and pesticides and smaller percentages of
units have a pressurized holding tank so that treated water is readily available. Reverse osmosis units are also very was teful as typically only 10 to 25 percent of the water going into the unit makes it past the membrane.The rest ofthe water goes down the drain. Some units also run all the time, even when the holding
door to door water filter salesman is on
aluminum. But the effectiveness of the
tank is full and this can also waste a
the loose. But have you ever taken the time to think about what these people are selling? Although there are many
filter is very dependent on the size of the
significant amount of water. Reverse os mosis is a technique used in full scale
suppliers will begin to receive a plethora of phone calls, gener ally from the same area, with questions regarding the quality of mu nicipally supplied drinking water. This is usually an indication that the local
trade names and manufacturers, there
are really only four different types ofinhome water treatment devices, granular
water but this only extends the life of the filter slightly, as it only removes a small percentage of what has been trapped by the filter. Carbon filters are effective in
filter and the contact time with the
water. The larger the filter and the lon ger the contact time,the more effective it will be at removing those substances. In
treatment plants. Its most common ap plication is in the desalination of seawater.
other words those small units that fit
activated carbon, reverse osmosis, dis tillation and water softeners.This article
right on the tap are totally useless. Gra
briefly describes each of these systems and explains what they will and will
remove lead or other heavy metals and
Water distillation units boil water, collect the steam and condense the
will not soften the water. The most im
steam back into water. Anything that
not do.
portant thing to remember about a car bon filter is that it must be changed on a regular basis. Once the filter is clogged it will not remove anything and may even release some previously filtered out ma terial back into the water.Clogged filters can also become a breeding ground for bacteria that would actually impair the water quality. Granular activated car bon is one of the techniques used at full scale water treatment plants where the source water is of poor quality.
will not go into steam is, therefore, re
Granular Activated Carbon
Granular activated carbon filters ty pically contain charcoal that has been activated by exposure to steam under intense heat. This process produces a vast array of tiny channels. As water passes through the filter, contaminants stick to the walls of the channels. These
filters will eventually become clogged and have to be replaced. Some systems provide a backwash system with hot
nular activated carbon filters will not
Reverse Osmosis
*AWWA Ontario Section Technical
and Research Committee 18
A reverse osmosis system works somewhat like a sieve. They contain a
Distillation
moved from the water. Distillation units
are very effective at removing chlorine, dissolved solids and heavy metals such as lead.They are typically not very effec tive against organic compounds such as pesticides and THMs. Other than a re-
gularcleaning,distillation units require no routine maintenance. Some units do include a carbon filter and in these
cases, the filter must be changed on a regular basis. Like reverse osmosis, dis tillation is also a very slow process with most household units producing some thing in the order of one litre per hour. Distillation is also relatively expensive
Envirottmenta! Science & Engineering. July 1992
by Brian Doherty* as typical units consume about 6 cents worth of electricity for each litre of water produced. One word of caution about these
and the customer is giving you a hard time, one of the points that you always should make is that drinking water only accounts for about twenty percent ofthe
treatment devices if you are thinking about using them at a location,such as a cottage, that is not serviced with treated drinking water. All three of the above devices will only work if all the bacteria
home water treatment devices is avail able from both the Provincial and Federal Ministries of the Environment.
In addition, the Canadian Consumer
drinking water oniy accounts for about twenty percent of the toxic chemicais that we absorb
has been first removed from the water so
toxic chemicals that we absorb into our
Magazine, 1990 no. 7 & 8, produced by
in an application such as thatyou would also require a unit such as a chlorinator
bodies. Eating and breathing account for the remaining eighty percent. Further information regarding in-
the Consumers Association of Canada,
or ozonator to disinfect the water.
contained an excellent article on this
topic.
Water Softeners Water softeners have been available
for a number of years and, although there are several makes available, most function in the same manner. It is dis
solved calcium and magnesium that makes water hard. Water softeners re
move these minerals by running the water through a resin bed that is satur
DISSOLVED OXYGEN TRANSMITTER
ated with sodium ions. The water ex
changes calcium and magnesium(hard ions) for sodium (soft ions) in the resin bed. Eventually the resin bed will be come saturated with hard ions and it
"D.O. measurements made affordable with new transmitter"
The Model 4320 Two-Wire Dissolved Oxygen Transmitter System includes a highly reliable D.O. Sensor and an indicating D.O. Transmitter. EIT's new instrument provides a 4-20 mA signal proportional to the dissolved oxygen sensed over ranges of 0-5, 0-10, or 0-20 PPM. The design also reduces the new system's Installation costs. For more information, Circle reply card No. 130
must be regenerated. This is accom plished by running a brine solution through the resin bed.The hard ions are replaced by the soft ions in the brine
drain. The only maintenance required
DISSOLVED OXYGEN MONITOR
is the addition of salt to the unit on a
"For control applications
regular basis so the unit should be lo cated where it is easily accessible. Per sons on sodium reduced diets should be wary of drinking softened water as the process does add sodium to the water. In addition, soft water is usually more cor
where measurement
solution and then flushed down the
rosive and can leach the lead out oflead
solder-s, thereby, increasing the lead content of the water. Typical household units can remove about 20,000 grains of hardness between regeneration. Scar borough's water has a hardness of 9.3 grains per imperial gallon which means the filter would have to regenerate every 2,100 gallons and would consume about 2 kilograms of salt in the process. The amount of water used in the regenera tion process varies greatly from unit to unit, but some can use up to 300 gallons per cycle which is not only wasteful but could also get expensive if your family
mi u.u.
integrity is critical" The Model 5520 Dissolved Oxygen Monitor Is designed for continuous measurement of D.O. wherever accurate D.O. measurement is needed. Using a field proven galvanic membraned sensor, this new D.O. monitor can be programmed to provide a 4-20 mA output over any range from 0-2 to 0-20 PPM. Also provided is a separate 4-20 mA output proportional to temperature over ranges from 0-10 to 0-50 degrees C. Two programmable alarms are standard, with adjustable deadband for on/off control. For more information, Circle reply card No. 147
uses a lot of soft water.
If you do get enquiries about water quality and in-home treatment devices Environmental Science & Engineering, July 1992
utnma
Summa Engineering Limited 1275 Eglinton Avenue East Unit 49, Mississauga Ontario L4W 2Z2
noineenno OlimitedO
Tel.: (416) 624-3188 Fax: (416) 624-1293 Summa Engineering Limited 3300 Boul. Cavendish
Suite 225, Montreal Quebec H4B 2M8
Tel.: (514) 487-7801 Fax: (514) 487-0058 19
Energy from waste
Landfill methane now generates 23 megawatts
Eastern Power Developers de
veloped the concept, and is currently operating the Brock West Landfill Gas Power Plant
fI I I I
in Pickering east of Metro-Toronto. A 23 Megawatt facility, the plant will save over 2000 tons of acid rain emissions per year by displacing coal fired power.The project is the first of its kind in Canada, and is able to satisfy the electrical needs of6000 homes.The power plant is fuelled by landfill gas produced by the anae robic bacteria present in the refuse. This
I M 1 M I t I I M 1 I I
I M I
I I 1,1 I
resource would otherwise have to be
■»f i ^ I 1
flared (eg: wasted). Metro-Toronto and the Town of Pic
kering will be paid an estimated $14 million over the first ten years of opera tion in the form of royalties by Eastern Power Developers Inc. Ontario Hydro purchases all of the power produced by this facility, under a 20 year contract with Eastern Power Developers Inc. a wholly Canadian owned company,cur rently in the process of developing an other landfill gas fuelled power plant at
Two centrifugal blowers which draw 5000 ftVm each from the landfill site, and feed It to the burners on the boilers.
the Keele Valley Landfill Site in Maple, Ontario. Methane is one of the most potent
greenhouse gases and has been iden tified as a major contributor to global continued overleaf
Bringing government and business together
Buyers and decision makers from business, private industry and the Ontario municipalities comprise the most powerful buying forces in Ontario. THE VISITORS • MUNICIPAL DELEGATES • MUNICIPAL BUYERS & DECISION MAKERS • &
PRIVATE INDUSTRV& BUSINESS SEEKING SOLUTIONS FOR • PLANT MANAGEMENT • PROPERTY NUNAGEMENT • NUNUFACTURING • MAINTENANCE •
Meet the challenge
Make that important connection with government (& private industry by showing your products & services at this exposition. THE EXHIBITORS • ENVIRONMENTAL • TECHNICAL • PLANNING & CONSULTATION •
HEALTH & SOCIAL • PUBLIC WORKS • RECREATIONAL • PUBLIC SAFETY • OFFICE EQUIPMENT & FURNISHINGS • GOVERNMENT & GENERAL SERVICES •
Free admission: Passes to the exposition are available from exhibiting companies or by photocopying this advertisement pre-registration is not available for this trade event.
THE SHOW FOR PRIVATE INDUSTRY & MUNIdPALITIES PLAN YOUR VISIT NOW FOR A UGUST 24 - 251992!
THE ONTARIO MUNICIPALITIES SHOW 1992 METRO TORONTO CONVENTION CENTRE This event is beiiiE held in conjunction with the 93rd ANNUAL CONFERENCE OF THE ASSOCI ATION OF MUNICIPALITIES OF ONTARIO. FOR INFOR.SIATION CONTACT JOCELYN FIELD
TEL: (416) 971-9526 • FAX: (416) 971-9682
20
Atttm
For more Information, Circle reply card No. 131
Environmental Science & Engineering. July 1992
IntroducingAccuWeirZero SubmergencePumps
HigherPumping Rates in Low Recharging Wells ccuWell Zero Submergence Bladder Pumps from Isco are the fastest and most efficient way to purge and sample low recharging wells.
Unlike most bladder pumps, AccuWell Zero Submergence Pumps do not require submerg ence in several feet of water to operate. In fact, our patented design allows you to efficiendy pump in as little as 2" of water. Zero submergence pumps save you time in low recharging wells, plus they offer you these additional benefits;
11 Faster and easier decontamination than regular bladder pumps.
H Meet EPA guidelines for true representative sampling.
^ Four different models to meet your exact monitoring requirements.
m Rapid sampling at the water surface. Find out how AccuWell Zero Submergence Pumps can save you time and money in your groundwater monitoring and remediation programs.
♦>»v*
ti. PI 1 ^-M-
^|1
II I' liii^i^^
1
•m
Nortech Control
Equipment, Inc.
fC| ^'1
135-4 The West Mall
(r-—«-'
Ftobicoke, ON M9C IC2 Phone: (800) 263-3427 (416)622-7820 fax: (416) 622-6776
"4
ISCO
"""T 'H
Quality products for monitoring the world's water For more information, Circie repiy card No. 132
Landfill Methane continued BOILER BO. 1
warming. Landfill gas consists of 50% CO2 and 50% methane. This plant is an economically self sufficient greenhouse
FROH LAMDFILI
NDFILL
SITE
gas reducer. The process used at the Brock West Power Plant involves piping the landfill gas from the gas collection system to two boilers located in an adjacent power plant building. The landfill gas is burned in each boiler by a low BTU gas burner, thus heating the water to pro
STACK
BOILER NO. 2 LANDFILL GAS BLOWERS H GH PRESSURE STEAH
EASTERN POWER DEVELOPERS INC. TURBINE
Steam produced by the boilers is used to drive a full condensing steam turbine, which in turn drives a 23 megawatt syn chronous generator. The steam is con densed back to water by a wet surface
BASIC SCHEMATIC LOU PRESSURE STEAM
WET SURFACE AIR-COOLED CONDENSER
air-cooled condenser and returned to
feedwater and the wet surface air-cooled
condenser spray water is taken from two infiltration galleries near West Duffins Creek. The boiler feedwater make-up is further purified by a reverse osmosis unit and a mixed bed deionizer.
To maximize the efficiency of the plant, the flue gases from each boiler
GENERATOR
BROCK WEST POWER PLANT
duce steam.
the feedwater heating system before being reintroduced to the boilers. Make-up water for both the boiler
TO ONTARIO HYDRO
r
'
CONDENSATE PUHPS
pass through an economizer before be ing expelled up the stack.Three stages of feedwater heating using turbine extrac tion steam improve the plant efficiency. The plant is staffed by 13 licensed sta tionary engineers who operate and maintain the plant on a 24 hour/day, 7 day/week basis. The electricity generated by the plant
is stepped up from 13,800 V to 44,000 V by a transformer, and then transmitted to Ontario Hydro's grid. Air quality in both the Town of Pic kering and the Province of Ontario has improved as a result ofthis project. Prior
to the power plant going into service the landfill gas was burned in four flares. Now it is burned in two new boilers which
provide better mixing of the fuel which ensures more complete combustion. The higher point of discharge from the stack also results in better flue gas dispersion. By displacing 23 megawatts of On tario Hydro's coal fired power, the Brock West Power Plant has reduced
...is mass flow
MASS FLOW METERS
acid rain emissions(SO2) by over 2,000 tons per year and has reduced green house gas emissions (CO2) by over 250,000 tons per year. For more information, Circle reply card No. 249
ENVIRONMENTAL S®Q®K!(S® Ss.
August-September Closes August 27
KENT
(overrun issue) Indoor air quality Typical Filtration System
Instrumentation developments Pipe specification and installation
Fluoride, ammonia & nitrate monitors ABB KENT TAYLOR 1825 Dundas St. E., Unit #7, Misslssauga, Ont.
L4X 1L6(416)629-1428 Fax (416)629-3171
Valve & hydrant maintenance
•FLOW •PRESSURE
Corrosion prevention and control Coatings and water quality
• LEVEL •ANALYTICAL
•CONTROL
CETECH '92 show special Trenchless technology To reserve space, or for further details, phone Steve Davey, Sales Director — (416)727-4666.
For more information, Circie reply card No. 133 22
Environmentai Science & Engineering. July 1992
U.K. Report
by Tompavey
EC's blue flag designates safe UK bathing beaches the Conqueror defeated Harold in 1066 in what was the first Battle of Britain.
"'•j"'' tVui.
BYPASS CONTRa
'fV-'-vrV
MANHOLE
L^3r.^«.^ r~..-
'.•'.r e'
STORMWATER OUTL£T MA^MOLE
UNDS^PLOW CXniETPlPE
drawn inwards and downwards to the STORM DISCHARGE
SANITARY SEWER CXMTROL MANHOLE
REG-LPFLO VORTEX VALVE
EXISTING DRY WEATHER FLOW BYPASS
Hastings has a two mile long outfall into the English Channel, giving additional beach protection. A major departure from the conven tional approach was the installation of five Storm King Overflows along with 10 Reg-u-Flo Vortex Valves(see drawings). With the Storm Kings, solids are
STORMWATER SEWER
REG^imO VORTEX VALVE
centre base and directed straight to the sewerage system with the comparatively clean water diverted from the system, into the streams and ultimately to the sea.
SYSTEM SCHEMATIC
MAX PSMITTED DISCHARGE
SANITARY SEWB1
TOWWTP
OF A TYPICAL STORM KING DYNAMIC SEPARATOR INSTALLATION
There's a new Battle of Britain
being fought on UK beaches — this time the prize is the covetted blueflag of the Euro pean Community.In 1976 an EC Direc
When first installed in 1984, the sys tems were comparatively new.Since the
flood control equipment was installed, the system has been monitored by con sultants on behalf of Southern Water, a STORMWATEH SEWER
privatized water board. Bexhill-on-
overloading of the sewerage system. A short sewage outfall was sealed and the flow diverted to Hastings where William
Sea's EC blue flag — still flying the sum mer of'92 — is the final seal of approval that the system has worked as designed. For more information, Circie repiy card No. 248
tive laid down strict standards before an
Announcement
EC 'blue flag', could be flown. The blue flags are an EC seal ofapproval,indicat ing those beaches which have EC safe water quality standards forbathing. Na turally there are strong economic con siderations for holiday resorts quali fying for the right to fly the blue flag. But even in 1992,many British beaches still could not meet the blue flag stan dards. When I was there in June, the
issue was a continuing media event sim ply because not qualifying for the flag can be costly to some resorts. A rival UK beach safety flag was being touted but I think the EC flag will be the one sought out by vacationers.
As in Canada, many factors can con tribute to beach water quality. In recent years,the(UK)Consumers Association carried out its own viral and bac
teriological tests on 15 beaches over a ten day period and only one,Bexhill-on-
Sea, a Kent resort on the English Chan nel, passed on both counts. A major factor in Bexhill's success was the minimization of animal fecal
matter being flushed into the sea during flood conditions. In addition to the en
gineering approach, Bexhill also sup plied additional litter bins and 'doggie
X Adei Ashamaiia, P.Eng
Donald Kemp, P.Eng
The President of MacViro Consultants Inc.,Sid Glllespie,P.Eng.,Is pleased to announce the appointment of Adei F. Ashamaiia, P.Eng., as Manager of the Water Resources Engineering Group and F. Donald Kemp, P.Eng., as Manager of the Water and Wastewafer Treatment Group. Mr. Ashamaiia has more than 25 years of diversified experience In Canada and abroad Including municipal engineering, water resources, hydrotechnlcal studies, stormwater management, and hydraulic and hydrologic analyses. Mr. Kemp has more than 15 years of experience In Industrial and municipal wastewafer treatment, water treatment and environmental planning. MacVIro Is a firm of consulting engineers, planners and scientists specializ ing In the environment.
bins'for animal feces while also forbid
ding some areas of beaches to dogs. Bexhill also undertook several public works, designed to relieve flooding and
MaeVIro Consultants Inc.
For more information, Circie repiy card No. 134
Environmental Science & Engineering, July 1992
23
We're SSCAN-GRODYNE,with rhany years of experience in providing industry with analytical and environmental measurement packages — from portable instruments to elaborate systems — permanent or mobile configurations. Whether your requirements are for continuous emission monitoring, ambient air or water
quality, we have the proficiency to recommend, design, and provide the start-up and commissioning of your project.
In addition, SSCAN-GRODYNE supplies only the finest, quality-built instrumentation. To you, this means maximum system up time, superior product performance and lower cost of ownership. Brand names include HORIBA, environnement SA, KURZ,PANAMETRICS, NOVALYNX.
So the next time you have a need for monitoring expertise, SSCAN-GRODYNE can be quite instrumental to the efficiency and cost-effectiveness of your installation. Call us for full information on our products and systems — available nationally.
SSCAN-GRODYNE 7222 Flint Place S.E., Calgary, AB T2H 1Y8 Phone:(403) 253-2241 Fax:(403) 253-2275
jr more informaiioh, Circle reply card No. 135
Fighting the iow bid mentaiity
By Tom Davey
Value — not price — is vital in choosing environmental lab services
Imagine the scenario. Your worst fears have been realized and doctors
have recommended surgery. But, once sedated, your fears have given way to more reassuring thoughts as they wheel you along the corridors enroute to the operating theatre. You know you have had X-rays, brain scans and a bat tery of tests done on state-of-the-art equipment. Then results were inter preted by specialists with years of train ing. Moreover,as a Canadian you know that our medical teams are among the best in the world. As the anaesthetic is administered
you are surrounded by a team ofgowned masked experts, the cream of the medi cal profession, trained and dedicated to restoringyou to health. Collectively they represent decades of intensive research and training. As the anaesthetic takes over your mind, you replay this com bination of high-tech health expertise as a final reassurance. But suddenly a star tling thought occurs: after all this stateof-the-art training and technology, what
if the actual scalpel blade was chosen with price the determining factor? The situation is not as far fetched as it
seems. Many purchasers of environ mental laboratory services are driven by price, not quality. Considering the fact that millions, sometimes hundreds of millions of dollars, could rest on the
accuracy and integrity of environmen tal analyses, it is as senseless to drive down lab fees through a low bid ethos as it would be to 'low-bid' scalpel blade purchases. Literally and metaphorical ly lab fees are but the tip of the moun tainous costs of environmental remedi
ation projects, real estate deals, litiga tion, corporate reputations and other
Don Mackay, Ph.D, P.Eng, a professor of chemical engineering at the University of Toronto, wrote a brilliant article in the February 1989 issue of ES&E in which he coined the phrase: the incomprehensibility of tinyness. He also suggested remedial action in Canada was suffering from 'jurisdictional overkill' or, as he put it paralysis by analysis.
geon to perform a vascectomy?"* Put simply all labs are not alike.Some are better equipped than others; some are better staffed; others are simply bet ter run. Moreover the analytical field has seen quantum leaps in its capabili ties in recent years which are virtually unmatched in any field. What other sci entific profession could match this pro gress of upgrading testing capabilities from one part per ten thousand to parts per quadrillion in less than three decades? Dr. Don Mackay,writing in an earlier ES&E, called this The incom
prehensibility of tinyness: "We are now dealing with concentrations in the range of nanograms, picograms or femtograms per litre. Even scientists have difficulty remembering what these prefices mean," he noted.
Put simply all labs are not alike. Some are better equipped than others: some are better staffed: others are simply better run.
Canadian Association of Environmen
tal Analytical Laboratories (CAEAL); what about errors and omissions insur
ance on analyses performed; what about knowledge and coverage of envi ronmentally significant parameters? These are some of the questions clients should be asking before they come to the area of price. Value, not price, is your best safe guard. Earlier this year a BC man was jailed for 90 days for an environmental offence. But corporate executives face other hazards as well as jail terms. In a recent Ontario case, the court was criti
cal ofthe cost cutting measures imposed by a Vice President which "overloaded" one of his more junior officers, leaving him insufficient time to deal with en vironmental issues. Both the President
and Vice president of Bata Industries Limited were convicted offailing to take "all reasonable care to prevent the cor poration from causing or permitting an unlawful discharge" under the Ontario Water Resources Act.**
Not only were fines of $12,000 each
environmentally related projects. We are not talking about buying blin dly here.The lab industry is highly com petitive and there is nothing wrong with trying to get the best deal for your com pany. But quality control and quality as surance(QC/QA) — not mere price — should be the motivational factors. Re
cently I posed the question during a pre sentation at the Association of the Che mical Profession of Ontario annual
meeting: "Do your clients use the low bid scenario when contemplating a sur-
It cannot be stressed too strongly that the cost of analytical data is minuscule at the front end; the factors they apply to are often astronomically costly as end results.
Don't be afraid to ask some questions. Does your lab use published and ap proved methodologies recognized by such agencies as the EPA or MOE re garding recommended sampling fre quencies; what about round robin studies performed by Environment Ca nada, Environment Ontario or the
Environmental Science & Engineering. July 1992
imposed, but the corporation was for bidden from indemnifying the two di rectors for the payment of their fines. While laboratories were not a factor in
the ES&E report ofthis case,the senten ces were a chilling reminder ofthe value of reliable analytical environmental data obtained from reputable labora tories.
* A reportofthls meeting was published in May '92 issue of ES&E, page 22. ** Both cases are reported on page 55, ES&E May '92. 25
fl
fmt CANVIRO, our quality program begins with your Initial contact with our laborator From sample container preparation through the reporting of your results, established QA/QC procedures are strictly followed. A dedicated QA/QC officer oversees and revlev
fhe enfire process. Analysis Is performed on state-of-the-arf equlpmenf using approvi
methodologies that meet all requirements of regulatory guidelines. Our staff of higt
qualified personnel Is dedicated to ensuring analytical procedures are applied propei and that data Is Interpreted correctly.
State-of-the-art equipment, approved methodologies, an Intensive QA/QC program a dedicated personnel. Your best solution for meeting analytical needs.
CANVIRO Analytical Laboratories Ltd. 50 Bathiurst Dr., Unit 12,
Waterloo, Ontario N2V 205 For more information, Circle reply card No. 124
Phone; 1-519-747-2575 Fax: 1-519-747-3806 Member of the Canadian Association of Environmental Analytical Laboratories (CABAL)
26
Environmental Science & Engineering, July 1992
Wastewater treatment operations
By R.J. Willcocks, P.Eng.
Ontario digester gas code â&#x20AC;&#x201D; the debate continues
Anumber of consulting engin
eers as well as suppliers of products and civil servants make up the committee which has worked on the preparation of the B105 Digester Gas Safety Code over the last number of years. It is the intention of the Regulators that the Code will be
come a national standard which would
parallel other CSA or Government standards.
There are a number of existing anae robic digestion systems in Ontario and elsewhere in the Country for that matter, that do not meet the requirements ofthe Code as is mentioned in the article. My question is whether or not systems which were installed during the late
1970's or 1980's to previous versions of the Code are really that "Unsafe". There has been pressure to issue a Code for digester gas safety which is enforceable and mandatory for some time.Previous versions ofthe Code have
been used by designers but compliance was optional. Designs for many MOE operated plants going back to the early 1980's required compliance with the Code. The MOE Design and Equip ment Section Issued Design Guidelines in 1983 for MOE operated plants which
Code compliant digester tanks at H.M. Baiiey Water Pollution Control Plant in Sas katchewan. Designed by Gore & Storrie, an 11.4 MUd expansion was completed late 1991.
problem areas are possibly the digesters
siderably more quickly than a relatively minor design change. By their nature, digester gas systems require propor tionally higher maintenance. Because it
basic digester gas safety questions are not that complex and were resolved by earlier versions of the Code. The real which have had no work done to them
is an Installation Code, there is little
were based on the B105-81 Code. These
since they were constructed in the early
Guidelines named specific equipment requirements and gave suggested sys tem layouts for the various components ofthe digester gas system.In some cases, systems and materials which were per mitted by the Code itself were not con sidered acceptable for MOE plants. As someone who has designed sys tems to meet "Codes" going back to the
1970's or before that. With the current state of Provincial
mention of maintenance requirements in the Code.There is no minimum oper
SR105 code in the 1970"s, I am con-
and Municipal expenditures, who is ex pected to complete this expensive work? How does Code enforcement raise the
money required? Any operator can tell you how difficult it is to get annual oper ating budgets approved even to allow for the recent changes in other regulatory requirements such as sludge disposal.
With the current state of Province and Municipal expenditures, who is expected to compiete
this expensive work?
cerned that successive revisions make
changes without apparent reason. Cer tainly the changes for the most part, are minor. Successive revisions give the im pression that previously accepted prac tices are now unsafe.The need for man
datory inspections gives this impression to the layman who has not followed the evolution of the Code. Designs of com plex systems evolve over time but surely *LaFontaine, Cowie, Buratto & Associates
let alone worry about routine main tenance of systems as they start to wear out. If an expansion at a plant is not planned,how is a costly expenditure for modifying the gas system incorporated into an annual budget? The cost would exceed the emergency reserve fund which most plants have to make major repairs. In an installed system, minor "design" changes can be expensive to implement.
ator qualification requirement either. The Ministry training programme gives courses in operation of digester systems and the licensing process may cover this requirement in Ontario. Other provin ces may not have a similar system. Let me deal with the implementation schedule. Aside from the economics,the
CGA has indicated that they are con
siderably behind schedule in the review of designs which are being submitted. As an example, drawings were submit ted to the CGA in January 1991 foranew
digester system which we designed to the 1987 version of the Gas Code. As of the
time the digesters were commissioned in April 1992, there was no formal com menton those drawings by CGA.In that time period, the 1987 Code was re placed. A field inspection by CGA staff of the installed system before com
missioning, revealed some relatively minor deficiencies in the design with respect to the new code as compared to the 1987 Code.
An example ofa deficiency is the need for check valve on the discharge from the low pressure gas booster to the boiler. This was not indicated as a re-
It seems to me that lack of main
tenance can make systems unsafe con
Environmental Science & Engineering, July 1992
contlnued overleaf 27
Wastewater treatment operations con t quirementofthe 1987 Code but is shown on a schematic in the 1981 Code. CGA staff indicated that this 1981 schematic
is still applicable in spite of the many changes in the Code. I am not sure that anyone outside of CGA would even consider that such a situation exists.
Many people may not even have the 1981 Code.
The 1981 Code required gas boosters for all boilers even when it was not re
quired for some low pressure burners. On one ofour projects, we did not install the gas booster because the burner could operate at a pressure as low as 75
does not totally comply with the Code or as otherwise approved. The MOE Ap provals Branch was indicated as being the appropriate authority to apply to with respect to this deviation although the system is owned by the municipality. Having taken more than a year to get any comment on the gas system and knowing how hard pressed the MOE Approvals Branch is to issue a CofA for a project for systems with which they are more familiar, it would be interesting to see how the process would work. I ex pect, the path of least resistance would be to follow the letter of the Code. In the
spectors could use the lists for orders against municipalities for unsafe work places.This seems to be the real thrust of where the Gore and Storrie article was
pointing. In the project which I referred to, the Ministry of Labour gave their approval of the plant as originally de signed.The CGA staffsuggested getting a deviation for the check valve which
suggests their agreement to the system as installed. Who takes responsibility of arguing with the MOL inspector whe ther their directive is truly a safety issue? As soon as such orders are given,it is dif ficult for anyone to take the respon sibility to have it rescinded. If a Code is "Enforceable",it gives the
able to indicate to the CGA and the
meantime, these digesters are produc ing gas which is being flared off to the atmosphere which is of concern to an
connotation that the provisions of the
MOE (who operate the plant) that the
other Branch of the MOE.
Code are defensible in a court of law. It
mm of water column. Because the code
was not mandatory at that time, we were
booster was not necessary and this was
accepted. A gas booster may be required when the gas burner requires a mini mum operating gas supply pressure
This is certainly a minor variation and has very little to do with safety. If however there were an accident at this
which is above a minimum digester
operating pressure or there is too much line loss in the connecting line between the digester and the boiler. How this relates to safety I'm not sure. Burner controls are designed to be failsafe and
when gas supply pressure is lost the bur ner is shut off. Most burners will switch
to the back-up fuel automatically. To meet the new mandatory code, a compressor which is expensive and complicates the system considerably is required for all low pressure systems.
would be interesting to see how the courts would interpret the contradictory provisions ofthe newCode as compared to earlier ones especially in light of the permitted deviations aspect. As a start, permitted deviations could be given to all systems which have been installed and inspected using the 1981 or 1987
Our designs 15 years ago,
versions of the Code at least until the
were safer than American
implementation frenzy dies down or for some specific time frame. As noted
designs are now and I am not aware that there have been
major problems in the United States either.
above schematics in the 1981 Code
still apply. Operator safety was the underlying reason for the need for this Code going back 15 years. Any real hazards were addressed in earlier Codes and by the
New boilers must be located at least 15
MOE Guidelines.The lack of minimum
metres from the digester, and in most
maintenance requirements may be of more concern than design. Catas trophic failures in Ontario in anaerobic digesters have certainly been infrequent and possibly non-existent in my 20-year experience. Our designs 15 years ago, were safer than American designs are
cases, the gas booster will be required because of the line pressure losses. This is a technical consideration and should
not be a regulatory consideration. The next question is whether it is "safer" to allow the gas pressure to equalize back into the digester where it can be controlled(our design as recom mended by the boiler supplier) or to keep the gas at the higher pressure be tween the digesters and the remote boiler, where there is no means to re
lieve it except to atmosphere or through the boiler (1981 Code). This is of even more concern in larger plants where gas
is stored at high pressure. There is no means to vent stored gas to the waste gas burner and the sphere over-pressure re lief releases gas directly to the atmo sphere if the pressure is too great in the sphere. This is supposedly a "Prohi bited" practice although it is obviously a safety consideration under the pressure vessels code. For a high pressure system, the discharge check valve is technically required. There is provision to allow the operat ing authority to grant a deviation to the new Code for "minor" variations and
this was suggested in this case. Techni cally however, it is now "illegal" for the system to be in operation if the system 28
plant, even an unrelated one, what would the liability implications be? It certainly seems that the thought process in implementing the Code is incomplete and whenever it is tied to the legal sys tem it will certainly be complicated more. There is obviously a transition period as the CGA (Canadian Gas As sociation) receives frantic calls from operating authorities to do a back-log of inspections and this will self-correct
now and 1 am not aware that there have
been major problems in the United States either. The more complex that a system is made,the more difficult it is to properly maintain and operate. A num ber of the cover failures for example have occurred because ofoperation and maintenance which are not covered in
itself.
the code. It is too bad that the current code has been formalized at a time when cost res
traints will make it virtually impossible to comply with. That is not to say that Operator safety should be sacrificed for a cost. These ongoing inspections will simply sit in files until and unless an accident occurs when they will be used to delegate liability probably when the non-compliance with the code would have very little to do with the accident. I have already seen cases where the CGA deficiency list serves as the basis for operator safety committees to con sider to refuse to work in the digester area of a plant. Ministry of Labour in
What would prompt an owner to
spend considerable amounts of money to change what was accepted in the 1981 Code for example, when there are many systems in Ontario which were installed in the early 1970's which have not ex perienced problems? Commercial buildings do not totally revise natural gas installations when the natural gas installation code is revised. In both
cases workers are put at "risk" or are they? Certainly there are many homes with very old natural gas furnaces as well. There are more natural gas explo sions in homes than digester gas explo sions in sewage treatment plants. continued next page
Environmental Science & Engineering. July 1992
New technologies
By John Van Egmond^
Purifying stormwater via a groundwater enhancement system
Flooding after rainfal s has in
fluenced many developments. Emerging design methods have included roof storage, on site
retention, infiltration, and storm water
quality.
street surface, channelization, inlet structures to divert water from the street
surface,and underground pipes systems to divert the water receiving bodies. Ex ceptions include unfiltered drainage
unit in this case. For peak capture the invert ofthe unit is set above the invert of the catchbasin lead. The unit diverts the
peak flow only shown in Drawing 4.
wells in some cities and the dissolution caves in others.
INCOMING DIRTY FLOW
EXISTING CATCH8ASIN
FLOOD, CATCHBASIN
The SAGES system includes easily removal fdters. a support grate, a well like device, and extraction chains. Fil
ters are graded from coarse to fine in the
direction of flow. The graded design re moves successively finer contaminants.
FILTERS
UNIT
CLEAN FLOW DRAWING
I
The graded filter resists premature cak ing. The support grate allows the filters to rest on a flat surface, thereby spread ing the media to fill the entire unit at depth.
RAIN
FLO\
Although several configurations are possible,those shown in Drawings 2.3.4 will suffice for discussion. In Drawing 2 is an existing system with catchbasin and storm sewer. Flooding flows
TIME EXISTING
SYSTEM
DRAWING
2
("flood)occurs when the capacity ofthe
The discharge through the SAGES filters will take principally one of two Depending on the design need, the unit forms, while partial flow develops inter can be used for pre-peak capture(Draw mediate cases. In both cases the total ing 3) or peak capture (Drawing 4). head available under storm conditions is then "fixed"except during partial flow For Pre-peak capture of storm water, catchbasin lead or sewer is exceeded.
The SAGES unit (Drawing 1) pre sents a new technology for municipal designer's options. The system can re duce the volume of storm water, the amount of erosion, and the contami
nant load reaching receiving bodies. A portion of the storm water is captured, then diverted at the point of origin, say at the catchbasin. from the system into the ground. Storm water management systems have large existing inventory. Most wes
the invert of the unit must be below the
invert of the existing catchbasin lead. Pre peak capture can be used when flows are too large for the existing sys tem. there is pollution and it must be treated at source, or when combined
tern storm water management systems
reaches the storm sewer until peak flows exceed the capacity ofthe unit. Peaks are
Wastewater treatment operations
The implementation of the Code
If the lowest filter has a permeability much lower than the upper filters,and if the "clogged" permeability of the upper filter remains greater than the per meability of the lowest filter, a constant/
sewers must be upgraded. No water
in North America include: shaping of the non-street surface, shaping of the
continued
conditions.
FLOOD INVERT PIPE INVERT SAGE
discharged into the existing storm sewer only when the invert ofthe pipe is below water. Flooding of the system will only occur when the hydraulic capacity of the system components are collectively exceeded. The hydrographs are shown in Drawing 3.
should not be over dramatized. It would
be my. opinion that more effort should be made in upgrading digester process design to make digester operation more predictable and efficient for sludge sta bilization. I would hope that those who are responsible for implementation
In some circumstances it may be de sirable to capture only Peak flows in the SAGES unit. In this case pollution cap ture must not be mandatory (say dis charge to storm water treatment plant is already in place downstream)in the pre-
SAGES RAIN
PRE
PEAK
CAPTURE
flow
would consider the real world realities.
peak phase. Flow is diverted to the exist
It seems that too many regulations are being implemented too quickly without consideration of costs. Certainly no operator should work in an unsafe
ing storm sewer system until the hy draulic capacity of the sewer or catch basin lead is exceeded locally. Only the peak flow is captured and treated by the
workplace but is it really unsafe? More dialogue should take place on the Code implementation. Perhaps this article will prompt some discussion.
near constant head outflow will result (Drawing 5). If the clogging ofthe filters *John Van Egmond is the inventor and is relatively rapid, and approaches that President of SAGES Storm Water of the lower filter with the lowest perProducts.
Environmental Science & Engineering, July 1992
TIME
EXISTING
SYSTEM DRAWING
WITH
SAGES
3
continued overleaf 29
New technologies con t contaminated, it is clear the total con
IFLOO INVERT SAGES INVERT PIPE
taminant load is washed into the storm
sewer system. As long as the flow reach ing the units is less than their hydraulic capacity, all of the sediment/contami nant load is captured.The sediment will lead to plugging,but not decreasing cap ture rates through the filter(unless there is a loss ofintegrity ofthe units).The for
RAIN
FLOW
TIME
MAINTENANCE
mation of interior cakes in the inter RAIN
STORM
media pores in deep filters may actually increase capture of contaminants.
SAGES PEAK CAPTURE
EVENT
DRAWING 5
Activated carbon is shown in most
SAGES configurations to be the bottom or last filter media. Carbon can remove
FLO\
dissolved and particulate matter.Freundlich presented a method for estimating the adsorption ofchemicals on receptor
TIME
EXISTING
SYSTEM DRAWING
WITH
SAGES
4
meability, decreasing flow will result. The units use mechanical and ad
sorption filters to remove contaminants. Mechanical filtration occurs by various mechanisms. These mechanisms in
clude interception, inertia, gravity, dif fusion, and hydrodynamic trapping. For adsorption chemicals attach them selves to free receptor sites and mecha nically to the filter media. While there is some debate as to if the
entire rain event or just the first flush is
sites of carbon as follows: X/M =
FfCg^''^. Based on Freundlich, and
tant.The unit provides the designer with another tool for flow reduction,flow di
version, erosion control, and pollution control and the technology provides enhanced opportunities in ground
data commonly available, it is possible
water management.
to estimate the life of these units once
Sources:
the
1. DRIVER, NANCY E.; Techniques for estimation of storm runoff loads, vo
average
contaminant
concen
trations are known. A minimum life of
one year is advocated. If unusual events occur additional filters may be added,or the unit may be disabled temporarily. Modern storm water design incor porates the lessons of 4,000 years of de sign effort. Recently, we have become more aware that storm water modelling is a whole system problem. Both flow volumes and contaminants are impor-
SERVING CANADA SINCE
lumes and selected constituent con centrations in urban watersheds in
the United States, US Department of the Interior, parer 2363), GB990.7 5 1990, USBN 890600400,1990. 2. TCHOBANOGLOUS, GEORGE ET AL: Water Quality, 1987, AddisonWesley, TD365.t38 1985, ISBN 0201 -05433-7, 1985. Circle reply card No. 258
Announcement
1978
Manufacturers and Suppliers of major equipmentfor water and
Summa Engineering Limited is pleased to announce the appointment of Angeio J. Valente to the position of National Sales & Marketing Manager. Angeio is a graduate of Seneca Col lege in the Electronic Technology Program. He has had 16 years of Sales & Marketing experience in Process Con
wastewater treatment
trol Instrumentation in both the Industrial
and Municipal field. The last position was held at Fischer & Porter Canada Ltd.
where he was the Marketing Manager, Disinfection Systems, responsible for
CANADA WIDE REPRESENTATION
the Introduction of the Fischer & Porter
8070 Jorry Est Anjou, Que, H1J 1H5 Tel:(514) 351-4632 Fax:(514) 352-3711
560 Bayvlew Avenue,Suite 219 Newmarket, Ontario L3X 1W1 Tel:(416)836-9490 Fax:(416)836-9070
For more information, Circle reply card No. 125 30
ultraviolet disinfection product line to the Canadian market. His many years of sales management experience will en force our plans for growth in the indus trial sector Canada.
In
Ontario
and
across
Environmental Science & Engineering. July 1992
.m:
New smoothwall interior
BOSS 2000: technical data
BOSS 2000 provides a corrugated exterior for superior strength, as weii as a thick smoothwall interior for maximum fiow. With a
Manning's 'n' value of .012, BOSS 2000 provides excellent hydraulic characteristics. Full size range BOSS 2000 is available in 4" to 36" diameters as non-perforated pipe, perforated pipe, or perforated pipe with polyester SOCK™ filter. Custom fittings are available on request. Easy to Install BOSS 2000 is light in weight for ease of transporting, handling and installation, requiring minimum work crews and equipment. It can be safely cut to size on-site — even using a chain saw! Once installed, it is highly resistant to both abrasion and chemical attack in most applications. Head Office
Big '0' Inc. 254 Thames Road East Exeter, Ontario MOM 1S3
(519) 235-0870
34601 Vye Road Abbotsford, B.C. V4S 4N7 (604)850-0753
• Manning's coefficient of 'n' = .012 at flow velocity of 0.75 m/s • Pipe stiffness of 320 kPa at 5% deflection as per ASTM D2412 • Recommended for use in soils having a pH range of 1.25 to 14, where it provides exceptional resistance to corrosion • Excellent impact resistance under winter conditions for yearround installation
Make the move to BOSS 2000 now! Ask for the BOSS 2000 brochure
... your introduction to a new era of optimum hydraulics, installation ease and dependable performance.
6014 - 64th Street
101 de Lauzon
Taber, Alberta H)K2G0 (403)223-3521
Boucherville, RQ. J4B106 (514)449-5004 1 (800) 361-1895
TM BOSS and SOCK are registered tradernarks of Big '0' Inc.
For more information, Circle reply card No. 126
Innovative techinology working for you
Making cement while protecting the environment nomically attractive opportunities have been exhausted. The next major poten tial opportunity is resource recovery
RELATIVE ENERGY REQUIREMENTS
(per unit volume)
from wastes.
The cement kiln is a rotary furnace 4 to 6 m in diameter and 50 to 200 m long. In order to make cement clinker, the
cement kiln, by necessity, possesses several unique characteristics which also ensures the safe combustion of or
Primary
Plastics
Copper
Ceramics,
Steel
Advanced
Glass
Concrete
ganic wastes. • The gas in the burning zone of a kiln reaches about 2000°C for a period of
Extruded
Vjtrilied
Cement
three seconds. A commercial inciner
Aluminium
Clay
Products
ator by comparison often burns
The Canadian cement industry
has a huge potential to provide an environmentally friendly solution to the management of some of society's wastes. We believe our proposals are safe, conserve scarce energy resources, reduce the cost of manufacturing cement, and could re duce CO2emissions,a contributor to the
global warming problem. The proposal is the recovery of re sources from wastes in a cement kiln.
Resource recovery may be in the form of partial replacement of kiln fuel using or ganic wastes or in the form of partial re placement of materialsfor raw feed using inorganic wastes from other industrial
below 1000°C for about Wi seconds.
These high temperatures make the cement kiln one of the most efficient
By Peter Walsanen, P.Eng*
devices for combustion of organic clay, sand and gypsum are common
wastes available.
in
• Disposal of ash is eliminated as any
Canada.
incombustible material becomes in
The plants are usually located near the major raw material — the limestone quarry — as close to the major markets as possible.The raw materials are quar
corporated in the cement clinker or in
sources
for
the
materials
used
the cement kiln dust, a by-product. • Any changes in stack emissions bet ween making cement with fossil fuels
ried, crushed and blended for unifor
versus waste fuels are minimal, and
mity. The raw materials are then pro portioned depending on the type of cement being made, mixed, ground
may actually decrease. Consequently no significant additional emissions
and blended.
are added to the atmosphere. Tests may be required on a site specific
In an energy efficient plant, the raw materials are fed through a preheater
exists.
tower where the heat from the exhaust
basis for confirmation, if doubt
• Unlike many industrial furnaces, the
gases from the kiln is transferred to the
kiln's raw materials are alkaline and
Many waste materials can be utilized
raw materials to conserve kiln fuel. The
by the cement industry to replace the
raw feed passes through the kiln at a rate controlled by the slope and rotational speed of the kiln. Fuel is forced into the
trap both hydrogen chloride and sul phur oxides as stable compounds of
processes.
normally used constituents that are re
quired to make cement. By replacing a raw material with one that is perhaps partially or fully processed, the energy requirements of the kiln may be re duced. The waste that is incorporated does not have to be disposed of which reduces the demand on existing landfill or storage facilities. The specific treatment that will be examined in this paper is partial fuel replacement with organic wastes. The same technology applies to all organic
waste fuels such as scrap tires, refuse derived fuel from municipal garbage, solvents, wood wastes, some industrial
sludges and shredder fluff from auto mobile recycling. Concrete is made from sand, stone,
cement and water. I will be describing the cement manufacturing process, the gray powder — not concrete. To make cement, a source of lime, iron, silica,
alumina and gypsum are required. Limestone, steel manufacturing wastes,
lower end of the kiln. The materials are
These are the characteristics which
partially fused at temperatures around
make a cement kiln suitable for burning
1500° to produce a product called clin
organic wastes.
To give some scale to the potential for contributing to the waste management problem, 1 will give you some exam cement. ples. A major cost of cement manufactur • Ifevery plant in Canada replaced 20% ing is energy. In 1990 the industry used of its kiln fuel with tires, a typical re 52 million Giga joules of energy which placement rate, we could consume all is the equivalent of about 1.3 billion lit of the 26 million tires wasted each ker. After cooling,the clinker is blended with a small amount of gypsum, and ground very fine to produce portland
res of oil.
year.
Since the dramatic increase in energy • If the industry replaced 15% ofits kiln costs in the early 70"s, process changes fuel with Refuse Derived Fuel(RDF) have been made resulting in a 25% re assuming that 60% of garbage is re duction in energy use per tonne of cyclable and/or non combustible and production. the remaining 40% is suitable for During the same period a switch to RDF,the industry could use the RDF cheaper more available fuels occurred. from about 10% of Canada's 16 mil
• Bunker oil usage dropped from 39% to 2%.
• Natural gas usage dropped from 49% to 24%.
• While coal and coke usage increased
*Regional Director, Canadian Portiand Cement Association
32
cement clinker instead of contribut
ing to acid rain.
lion tonnes of municipal garbage. • Ifevery plant in Canada replaced 47% of its kiln fuel with hazardous indus trial wastes, we could use 100% of the one million tonnes available of or
ganic hazardous industrial wastes
from 12% to 74%.
-Further energy conservation is tech nically possible although the most eco
which are currently being treated offsite.
Environmental Science & Engineering, July 1992
AlOrOFPUMP WITHOUT A LOT OF NOISE
AUTO-START
GORMANBUPP
" •
i
Mobile Sewage Pumping Unit handles emergencies quietly and efficiently. Gorman-Rupp's new portable sewage pumping system has a sound-suppressing enclosure that reduces operating noise levels below EPA 76 DBA Standard. This makes it ideal for
emergency standby and sewage by-pass jobs in heavily populated areas. The unit features a 6" T Series self-priming, centrifugal solids-handling pump. It can pump up to 1,500 gpm and handle 3" diameter solids with heads to 120 feet. Pump will cycle automatically in response to signal from submersible trans ducer liquid level control - allowing reliable, unattended opera tion. The entire unit - including controls - can be locked for extra security and safety. Meets Transport Canada regulations. Other features include: A removable coverplate for easy access to pump interior that permits fast removal of clogs
without disconnecting piping or hoses. Centralized control panel with engine start switch, suction and discharge pressure gauges, elapsed running time meter plus other features. Steel frame with heavy-duty torsion bar suspension and hydraulic surge brakes. Removable canopy for easier servicing. Extra large capacity fuel tanks for 24-hour service. Full complement of running lights and reflectors for high road visibility. Contact us now for complimentary fully descriptive literature!
GORMANRUPP
For more information,
Circie reply card No. 105
Gorman-Rupp of Canada Ltd. 70 Burwell Rd., St. Thomas, Ontario N5P 3R7 Phone:(519)631-2870 • Fax:(519)631-4624• Telex: 064-73530 "Distributors across Canada"
Water Treatment
Water research is alive and weii in Ontario The Ontario Section AWWA is in
the process of preparing a series of articles focusing on research activi ties on practical process improve ments in water treatment and pro duct development. Two pilot plant studies being par tially funded by the Ontario Ministry ofthe Environment,Environmental Technologies Program include: membrane filtration of highly col oured soft water and the use of ozo-
nation and granular activated car bon for organics reduction. Operating authorities such as Metro Toronto and the MOE are
undertaking studies to lower alumi num residuals in treatment plants which use aluminum sulphate as a primary coagulant. Basic research of this pature, when combined with work being carried out by the AWWA Research Foundation, will provide considerable guidance to other ope rating authorities for future impro vements to water supply facilities. Future articles will provide details of
faced with a period of unpreceden ted challenges. The identification of new contaminants, emerging regu lations and heightened public aware ness of water quality have all contri buted to the situation.
To meet this challenge the indus try requires new responses. Alterna tive treatment technologies such as ozonation and granular activated carbon (GAG) adsorption must be investigated. Because these techno logies represent a significant depar ture from current practice, they will require a more thorough investiga tion than has been traditionally associated with treatment plant up grading. Since many utilities will be facing this situation, there is an urgent need and a potentially subs tantial market for a tested modular
drinking water treatment pilot plant which could be marketed in Ontario and elsewhere.
The Ontario MOE (Drinking Water Section),the Brantford Public
study results and contact individuals
Utilities Commission, the Regional Municipality of Ottawa-Carleton
from whom more data can be received.
and the Windsor Utilities Commis
Other topics to be covered include:sum mary of research activities related to
sion are developing and testing such a pilot plant in association with the University of Waterloo, with the funding from the MOE Environ mental Technologies Program. The study will also provide valuable data, particularly with respect to ozone,for possible process modifica tions at the three municipalities. Work on the project began in Novem ber 1990 and is anticipated to be complete by November 1993. The pilot plants will be"modular" in that any of the units within the treatment configuration can be added,removed or repositioned with little difficulty. Unit processes being considered include: presedimentation tanks, rapid mix chambers,
control of zebra mussels and oxidation
by-products
(e.g.,
ozonation
by
products).
Design,evaluation and marketing of a modular drinking water pilot plant for the 1990s The drinking water treatment industry in Ontario is currently
Drinking Water Conference The Fifth
National Conference on
Drinking Water will be held on Septem ber 13-15. 1992 in Winnipeg, Manito ba.
The theme of the conference is "Dis
infection Dilemma: Microbiological Control vs. Byproducts". The con ference technical program will consist oforal presentations and poster presen tations concerned with the issues of dis
infection technology, trihalomethanes and other disinfection byproducts, emerging regulations and guidelines, monitoring and anlysis. A public forum with the theme"How Safe is Our Drink
ing Water?" is also scheduled. Registration information can be ob
tained through the following: Fifth Na tional Conference on Drinking Water, Box 25172. 1650 Main Street. Winnipeg, Manitoba, R2V 4C8. Telephone: (204) 339-3330, Fax:(204) 334-9813. 34
flocculation/sedimentation tanks, flotation units,settled water storage tanks, ozone contactors, filters and GAC contactors. Parameters which will be moni
tored include: temperature, pH, hardness, alkalinity, turbidity, dis infectant residuals, U V,colour,total organic carbon (TOG), trihalo methanes (THMs) and trihalomethane formation potential (THMFP), chlorine demand, major ions, coliforms, heterotrophic plate count (HPC) organisms, heavy metals, nitrogen compounds and phosphorus. Also being considered are: threshold odour number(TON), total organic halides(TOX)and total organic halide formation potential
(TOXFP), ozonation by-products (e.g., formaldehyde), other chlorination by-products, assimilable orga nic carbon (AGG), specific organics (volatile and extractable), Giardia and additional odour monitoring (flavour profile analysis and chromatographic sniffing). Aluminum in Metro Toronto's
drinking water The current debate on aluminum
in drinking water is affecting all the utilities using aluminum based coa gulants. While some researchers argue that the presence of aluminum in the brain cells causes Alzheimer's
disease, others hypothesize that the disease itself alters body chemistry to allow accumulation of aluminum.
Some researchers have proposed that an immediate goal should be set to reduce aluminum in drinking water below 50 q/L with a 5-year goal of 10 fj/h. The average aluminum levels in the drinking water in Metropolitan Toronto are well below the Ontario
Drinking Water Objectives(ODWO) guideline of 100 q/L. Metropolitan Toronto's Works Department is con sidering options to further reduce the level of residual aluminum in
drinking water to address healthrelated concerns and some of the
operational problems experienced in
tbe distribution system. Two inde pendentstudies for the Works Depart ment recommended optimizing the coagulation process by suppressing
pH by the addition of sulphuric acid which resulted in minimum soluble aluminum in the treated water. Further in-house bench-scale tes
ting was carried out to confirm the required dosages of sulphuric acid and to estimate the costs. It was
determined that 24 to 30 mg/L of sulphuric acid would be required to suppress the pH of water (after prechlorine and alum) to 6.9. Prelimi nary cost estimates indicate that the
cost of using sulphuric acid at Metro's filtration plants would be around $3 million, exceeding the current total budget for all the che micals.
Gurrently,Metropolitan Toronto's Works Department is investigating other options such as the use of nonaluminum based coagulants for water treatment. The final selection
of the process(es)is likely to be affec ted by the input from various public and government agencies. Report by the Technical & Reseach Committee Ont. Section AWWA.
Enviroumeiiial Science & Engineering. July 1992
Water Treatment
Lead is the hottest AWWA item in US cement of corrosion control. How
ever, this change will not have a prac tical effect for most water utilities
since statistically the 15ppb level would be expected to be achieved only after a year ofoperation with cor
m
much controversy and negotiations on other provisions in the bill. Most sub committee members expressed reser vations about the bill which they in tended to bring up at full committee. It is noteworthy that the subcommittee
rosion control rather than at the
members raised the concerns which
o'nset.
were expressed in grassroots letters from AWWA members — in some cases using
H.R. 2840 was reported out of sub committee on November 4, 1991, after
the exact words verbatim.
New lead standards may be impos sible to meet
Lead legislation remains the hottest item on the AWWA legislative agenda. H.R. 2840, The Lead Contamination Control Act Amendments of 1991 intro
duced by Rep. Waxman (D-CA) have been marked-up by the House Health and Environment Subcommittee and
reported out to the full committee. At subcommittee mark-up Rep. Edolphus Towns (D-NY) introduced amendments which were unanimously adopted by the subcommittee.The most significant change made in H.R.2840 by theTowns amendments was deleting the provision prohibiting EPA from using PQL (Practical Quantitation Limits). Other changes were an attempt to ad dress the impractical lead standards which trigger corrosion control or lead service
line
removal; however, the
changes will have no practical effect
We never know
what projects will come down the pipe.
since it is doubtful that the amended
level can be achieved by water utilities. In addition to removing the prohibition on the use of PQL, the Towns amend ments make the following changes: • Retains the Tap Water Lead Limit (TWLL) trigger of lOppb at one exceedance; however,it allows 1 sample to exceed lOppb for each multiple of sample sets taken. (The minimum number of required samples is de fined as 1 sample set.) • Corrosion control timeframes are ad
justed so that water utilities are not penalized by the failure of a state agency to act. This eliminated the re quirement to remove lead service lines if a state agency did not act with in the schedule mandated in the bill.
At the National Research Council's Institute
for Environmental Chemistry, we apply inno vative technology to environmental issues. lEC assists Canadian industry by creating
technology to safeguard the quality of our air, land, and water. Toward this goal, we perform market-driven R&D and transfer technology designed for environmental applications. To discuss partnerships, licences, and other ways we can benefit your organization, con tact our Manager of Business Development, Terry Kimmel, at (613)990-6618, or fax (613)952-1275.
However, the time allowed for corro
sion control studies essentially re mains unchanged. • Water utilities would have one year to reach the TWLL oflOppbatthe 99th percentile before lead service line re moval would commence if the lead
Making the environment our business National Research
Conseil national
Council Canada
de recherches Canada
NKCfOC Canada
concentration did not exceed 15 ppb at the 90th percentile after commenFor more information, Circle reply card No. 102
Environmental Science & Engineering, July 1992
35
Water Treatment Chlorine ban proposed for water disinfection
CWWA adopts AWWA position statement
Throughout the summer of 1991, Greenpeace vessels dropped anchor
on home water treatment devices
in ports throughout the Great Lakes.
The purpose of the voyage was to promote zero toxic discharge into the Great Lakes System. The single
The Board of Directors of the Cana dian Water and Wastewater Asso
ciation has approved the adoption by CWWA of the position statement
most targeted chemical in the cam paign was none other than chlorine.
put forward by the American Water
The stated objective of the mission
treatment devices.
was to eliminate the manufacture
Public water supply authorities across Canada have expressed gro
and use of chlorine, including chlo
Works Association on home water
The position statement reads: "Home water treatment devices are
not required to protect public health when consumers are receiving water from a public water supply system that meets state, provincial, andfederal health standards or regu lations."
rine used for water disinfection.
wing concern with some of the mar
This summer's voyage ended in Traverse City, Michigan at the end ofSeptember to coincide with a meet ing of the International Joint Com
keting techniques used by some
Bonk, P.Eng., Executive Director,
home water treatment device sales
Canadian Water and Wastewater
agencies, particularly those which imply that local tap water supplies
mission (IJC).
are unsuitable or unsafe.
Association, 24 Clarence St., 3rd Floor, Ottawa, ON, KlN 5P3, Tel: (613) 238-5692, Fax:(613) 237-2965.
Ontario Section and other sections
in water treatment.
for the International Joint Commis
of AWWA to emphasize to the IJC, the enormous implications of ban ning chlorine from treatment of drinking water. Chlorine has been the leading defense against trans mission of diseases such as typhoid, diptheria, cholera and dysentry in water supplies. Extensive research
The costs in Canada of converting the vast majority of our water plants
sion, has advised that input of the
For further details contact: Steve
Submissions were made by the
to an alternate disinfectant such as ozone would cause extreme economic
hardship to customers ofcommunity systems. Benefits to the Great Lakes as a result of banning chlorine are
has been conducted to establish
less well defined than the benefits of chlorine in water treatment.
significant correlation of medical
The Honourable E.D. Fulton,
effects to chlorine at the levels used
Chairman of the Canadian Section
Ontario Section and others concer
ning the use of chlorine for water disinfection will be addressed in IJC recommendations. These recom
mendations will be made to the gov ernments of Canada and the United States in the Commission's Sixth
Biennial Report on Great Lakes Quality. (Ontario Section, Pipeline)
80 Years of Flow Measurement Experience Badger Meter is
â&#x20AC;˘OPEN CHANNEL
Flumes/Weirs/
dedicated to the
Compound
deveiopment and
Measurement
manufacture of
â&#x20AC;˘CLOSED PIPE
quaiity
Pressure Transit-Time
instrumentation for water and
Uitrasonio/Fiow
TubesWenturis/
wastewater
Turbines Non-Full Ultrasonic
markets.
Transit-Time
Pressure pipe, open channel, non-fuli pipe,
ACCESSORIES Recorders/
retrofit or new
Data Logger
with Level
applications. Badger has the expertise and knowledge to
Badger Meter
insure success.
Talk to the
P.O. Box 581390
Flowmeter People. Talk to Badger.
Tuisa, OK 74158-1390 (918) 836-8411 FAX:(918)832-9962
For more information, Circie reply card No. 106 36
EnvirnnmenrnI Srii'iirp iK' Ftioiiuvrinv liilv 1992
Ever feel everyone "knows the answer"
...until you have a prohlem? DITYT» DIMECH*
Solving problems in the waterworks fitting industry is a Terminal City tradition.
-Push Joint D.I. - MechanicalJoint D.I.
TER-MECH - Mechanical Joint Grey Iron
Terminal City provides you with access to technical product data through factory consultation.
Terminal City provides you with a complete fitting lineCompact Ductile Iron-AWWA C153, 4 inch through 16 inch; DITYT® or DIMECH®
Ductile Iron and Grey Iron-AWWA CIIO, 4 inch through 24 inch; TER-MECH or TYTON
Ductile Iron and Grey Iron-ANSI BIG.I, 3 inch through 30 inch; Flanged Fittings Terminal City also provides a variety of "Special" fittings for specific installation needs. One "Special" will do the work of two or more standard fittings.
Make the Right Connection...CALL
IRON WORKS LTD. Manufacturers of Waterworks Fittings, Gate Valves and Fire Hydrants 1909 Franklin Street,Vancouver, B.C. V5L1R1
•
Phone(604)253-7525 •
FAX(604)253-6365
For more information, Circle reply card No. 107
Environmenlai Science & Engineering. July 1992
37
Water Treatment
AWWA explores new communications strategy During an issues identification/ communication strategy session,
held recently in Chicago,30 key lea ders ofAWWA focused on the lack of
public confidence in water supplies and in the safety of drinking water. The group determined that in order
for the water supply community to improve its image, a two-way com munication strategy with the public could be very effective. Communication strategist Dr.
Peter Sandman of Rutgers University led the group in coming to the conclu sion that minimizing the possible health risks for drinking water, dis missing community reactions as irrational, and treating the public as if it were unable to understand the
scientific aspects of risk were not effective ways to achieve public con fidence. "One-way communication may be leading to an outraged public and stricter government regulation.''
Dr. Sandman's presentation argued that public reaction is foster ed more by outrage (non-technical factors) than by hazard (scientific data). For example, when people don't have choices, they become angry. People feel safer with risks that are natural versus industrial.
Less outrage is generated from a risk that is familiar than one that is not.
And the list goes on. By ignoring the outrage factors, utilities may have overlooked a critical factor in
building public confidence.
Mulfiparameter Water Qualify Data Systems
High Performance .^| .• 8 basic measuremenfs with *.J
The AWWA Public Information
Department is encouraging utilities to begin to recognize outrage, i.e., public feelings, and use a two-way communication process with the public. The Blue Thumb campaign can assist utilities in this process by opening the door for dialogue. It provides an opportunity for utilities to show how they safeguard and manage water and protect public
o_ne 3-1/2 inch diametei probe; • m Situ measurements to
!jO metofs in fresl- a-cC r
I
seC'vater. and pr'sundv ,"er
• d rect PC compoiibiity Durable and Sellable •"
health. It invites the public to join with them to solve serious environ
• 2-year warranty covers sl!„ parts and laboi, plua potd
shipment back to you
"One-way communication may be leading to an outraged public and stricter government regulation."
"
• watertight marine construction
mental and water problems. Here are some tips to help you begin to incorporate public involve ment components into your com munication programs:
terfper-jiure
Free Customer Support
s-j'inity
dissoivsd oxygen rr
• applications assistance
,
• training video
• When interacting with the public, recognize the importance of com munity input. In short, recognize that their opinions are as important as yours.
Easy to Use & Calibrate • 12-volt battery-operated •fieid-repiaceable probes
con-juc'cnce
. rcoox
conductivity
"•
• menu-driven software
have stood with them on issues of
deptn/ievel
I-
HOSKIN SCIENTIFIC LTD.
Vancouver (604)872-7894
.
'lam
Burlington (416)333-5510 Montreoi (514) 735-5267
♦he 'eoder
ic riurnble, n .ultiparameter
Water Quality Monitoring Instruments - think RELIABILITY
For more information, Circle reply card No. 108 38
• To the extent possible, involve the community in the decision-making process. After all, you need their support for rate hikes. They'll be more likely to vote with you if you concern to the entire community. • Identify and respond to the needs of different audiences. Although "public" is a collective word, there are in fact, many publics, each affected differently by an issue. Don't avoid environmental and pub lic interest groups just because they have been adversaries in the past. These organizations should be iden tified and spoken with about their concerns. You may find more com mon ground on source protection and other issues than you think.
Environmental Science & Engineering, July 1992
R&D News Zero Discharge Process
A process was described to delegates at the 27th Central Canadian Symposium on Water Pollution Research which
treats all process streams and washwater at the Black Photo Corporation main processing plant in Markham.
the effluent clarification and sludge thickening processes that may occur in the sedimentation tank, and accounts
for the interactions occurring between the aeration tank and the final settling tank. A computer program is used to obtain design results.
Ontario. A.R. Keen and R.J. Sinukoff of
ALTECH Environmental Consulting discussed this system which provides total water reuse and a dry sewer. Before the system was installed, up to 70.000 USGPD of wastewater were discharged from the facility. The closed loop pro cess treats and recycles water resulting in a final system by-product of up to 200 USGPD of mixed photochemical con
Contaminated Sediments In Halifax Harbour
Institut Maurice-Lamontagne scientist J.N. Gearing, together with D.E. Buck ley and J.N. Smith of the Bedford Insti
tute ofTechnology, have extracted cores of the 15-20 cm of sediments that have collected in Halifax Harbour over the
past 100 years to develop a chronology
basis for control measures such that en
vironmental impact is minimized and guidelines are met. The paper in the Canadian Journal of Civil Engineering presents an impact assessment of chlo rinated wastewater discharges from two water treatment plants in Edmonton.
of contamination. As described in the
centrate which is incinerated. Black's has now achieved a 97% reduction in process water usage.
Canadian JournalofFisheries andAquatic Sciences, pollutant hydrocarbon con
Design of Activated Sludge Systems A computerized algorithm published in the Water Pollution Research Journal of Canada was developed by O.Moreno.R. Leduc and R. Gehr for design and ana lysis of the steady-stage step-feed acti vated sludge system with secondary sedimentation. These University of Sherbrooke and McGill University sci
since about 1900. Aliphatic con taminants characteristic of sewage and urban runoff have had a steady expo nential growth over time, while aroma tic hydrocarbon combustion products are currently declining slightly. Heavy
entists took into account both the bio-
Plant Discharges The discharge ofchlorinated water from treatment plants to receiving water
degradation occurring in the aeration tank and the solids-liquid separation process. The algorithm also deals with
its toxic effects on aquatic biota and potential health hazards. A paper by University of Alberta scientists S.J. Stanley and D.W. Smith describes a transverse mixing model that incor porates both mixing and pollutant decay in assessing the environmental impact of these discharges. The results of such an analysis can be used as a
centrations have increased
100-fold
Metals In St. Marys River Sediments National Water Research Institute sci
entist A. Mudroch investigated the geo chemistry and distribution of several heavy metals in the bottom and suspen ded sediments in the St. Marys River. Ontario/Michigan. As reported in the Water Pollution Research Journal of Ca nada. elevated concentrations were ob
metals in the sediments increased from
served at the Canadian shore in the vi
1890 to 1970.
cinity of the Algoma Steel slag dump and near the Algoma Steel slip, par ticularly in the bottom sediment. Con
Chlorinated Water Treatment
centrations of Cr. Cu and Ni in sus
pended and bottom sediments increased
bodies has caused concern because of
continued overleaf
Newfor Wastewater Testing
Optional self-cleaning By-Pass Y Strainer is now available to reduce clogging and fouling
Hach CL17
Chlorine Analyzer Around-the-clock monitoringforjust pennies per hour* The CLI7 Chlorine Analyzer provides the continuous, accurate, on-line monitoring
required for optimum chlorine residual control. Thousands of facilities have discovered that the CL17 is the affordable way to eliminate expensive overfeeding while assuring full-time compliance.
■ USEPA-approved DPD colorimetric chemistry (for drinking water and wastewater) ■ Operates unattended for 30 days between reagent changes ■ Dual programmable alarms
■ Selectable recorder output and optional computer Interface kit *Based on five years of use excluding depreciation
For more informolion, request llleralure numbers 3879 and 1320. HACH COMPANY
HACH
P.O. Box 389
Loveland, Colorado 80539 U.S.A.
Service Centre in Winnipeg m Sales outlets throughout Canada
Telephone:(303)669-3050 Fax:(303)669-2932 For more information, Circle reply card No. 109
Environmental Science & Engineering. July 1992
39
R&D News at various locations along the river indi cating several different sources of these trace elements. The concentrations of
trace elements were generally con siderably lower in suspended sediments than in the bottom sediments.
Reduction In Pulp Mill Effluent Toxicity J.S. Gibbons and coworkers at the Pulp
developed to estimate chlorophyll a,
Wheeler and M. Kalin measured the
suspended minerals, and dissolved or ganic carbon concentrations simulta neously from a single measurement of the sub-surface volume reflectance spec trum in the optically complex waters of Lake Ontario. To estimate such aquatic
biological polishing of zinc and other heavy metals by perlphyton com munities at a polymetallic mine in Buchans. Newfoundland. As described at
the 27th Central Canadian Symposium on Water Pollution Research,six polish ing ponds were constructed in series near the effluent creek. The perlphyton population,growing on branches in the polishing ponds, was able to concen trate zine by a factor of 500. and barium by a factor of 22.900 over ambient water levels. Periphytic algal populations with proper scale-up may therefore provide substantial polishing capacity in
and Paper Research Institute ofCanada have assessed the effect of biological treatment on the environmental quality of high-yield mechanical pumping ef fluents. As described in a paper accep ted for publication in fVater Research, untreated effluents from one chemither-
wastewater from
momechanical pulping (CTMP) and three thermomechanical pulping mills were acutely lethal to fathead minnows
lAWPRC
Fate of Immiscible Fluids in the Saturated Zone
and the water flea Ceriodaphnia with 48 h LC50 values of 2.2% to more than 50%. The effluents also caused chronic ef fects at concentrations of0.01% to 5.3%.
After biological treatment, acute lethal ity occurred only with Ceriodaphnia using the CTMP biotreated effluent. Remote Sensing of Lakes In a paper published in the Journal of
active and decom
missioned base metal mines.
In the sub-surface, significant quan tities of chemicals will be dissolved by groundwater in contact with non-aque ous phase liquids(NAPL) and can re sult in groundwater contamination. A suitable understanding of NAPL fate in the subsoil is required to evaluate sour ces of existing dissolved chemical plumes,to predict plume migration,and to evaluate purging strategies where
concentrations requires a quantifica tion. as a function of wavelength, of the amount of scattering and absorption that may be ascribed to a unit concen tration of each aquatic component. Cross section spectra are presented for Lake Ontario and Lake Ladoga in Russia.
Great Lakes Research, R.P. Bukata and
colleagues from the National Water Re search Institute and the USSR Academy
Removal of Metals by Perlphyton Communities
of Sciences describe a model which was
Barringer Research scientists W.N.
NAPL remains in the sub-surface. Uni
versity of Waterloo scientist N. Guiguer
"Corrosion Fighting" Specialty Fittings ROBAR
Robar's specialty waterworks fittings are manufactured with corrosion-resistant
coatings and materials ... a sample of these products are shown below ...
msnnlE
The Original'
2606X11 SUInless Steel Service
All Stainless Steel
Saddle.
Repair Clamps.
trenchless
pipeline replacement The new TRS Hydrahaul system can replace watermains and sewers right under busy city streets without excavating a trench! Ductile and cast iron, steel, concrete and clay can be replaced with new PVC, PE and steel pipelines, size for size or largerXhan original.
Bronze 2706 Saddles Corrosion Protective
With Wide Stainless
Coating 1S06 Couplings
Steel Straps.
With Stainless Steel Bolts.
We Don't TKNCHliSSâ&#x20AC;˘ REPIACEMENT â&#x20AC;˘SYSTEMS
Dig it!
Trenchless Replacement Systems Ltd. 1600,144-4 Ave. S.W., Calgary, AB., T2P 3N4 Tel.(403)279-9876 Fax (403)236-9058 For more information, Circle reply card No. 110 40
For further details, please contact...
41*
ROBAR INDUSTRIES LTD. 12945 - 78th Avenue, Surrey, B.C. V3W 2X8 Phone (604) 591-8811 FAX (604) 591-5288 Toll Free 800-663-6553
For more information, Circle reply card No. Ill
Environmental Science & Engineering. July 1992
4
The Victaulic system...the complete,fast, economical and reliable wayto join pipe. Sludge clean-out and maintenance
Saving money in municipal treatment
are a snap. Each joint is a two-bolt
plant piping since 1925.
expansion are easy. Products are
The Victaulic system not only saves substantial time during initial installation, it also helps reduce
operation and maintenance costs.
union. Add-ons, changes, and
available for AWWA ductile or IPS steel, stainless, aluminum and PVC—even a transition coupling from ductile to steel.
Grooved end plug, butterfly, ball
You work with only two bolts,
and check valves are installed with
compared with 8 to 12 for flanges. No bolt hole alignment problems.
Easy field or shop pipe preparation.
two couplings. Fittings are grooved, ready for field installation. And products are available worldwide. Next municipal waste treatment,
New Vic-Plug® valve provides exceptional flow,
low maintenance, and fast, easy grooved coupling installation.
water treatment, lift station or
pump house, put the Victaulic system to work. We'U go the limit and beyond to save you time and reduce costs.
For more information, contact
i0^3^I i O vA goes the limit...
your Victaulic Distributor, or write
and beyond.
Victaulic Company of Canada Limited, Rexdale, Ontario M9W Only Victaulic has a complete line of couplings,
fittings, and valvesfor AVJWA ductile and IPS steel, stainless, aluminum, or PVC pipe.
5N7. Or call 416-675-5575. FAX; 416-675-5729.
For more information. Circle reply card No. 112
Vicuulic and Vic-Plug are registered trademarks of Vicuulic Company of Canada Limited.
©1989 Vicuulic. All rights reserved.
R&D News has developed a numerical model des cribing the fate of residual immiscible fluids in saturated porous media. A simulation presented in Water Science and Technology illustrates that immisc ible liquids can act as a continuous source of contamination in an aquifer for many decades. Oxygen Transfer in Diffused Aeration
In a paper accepted for publication in Water Research, K.I. Ashley, D.S. Mavinic and K.J. Hall describe the results of their research undertaken to examine the effect of orifice diameter, air flow rate, and reduced tank surface area on
University of Quebec in Trois-Rivieres was to evaluate tadpole blood parame
tamination. As described in a poster presentation at the 27th Central Cana dian Symposium on Water Pollution Research, tadpoles were exposed to dif ferent concentrations of cadmium over
R.J. Tkacz revealed the occurrence of and sediments downstream from textile
mills. The dyes were found in 1985 and 1986,but not in 1987 possibly because of improved waste treatment procedures. As described in the Water Pollution Re
search Journal of Canada, the most con taminated area was downstream from
mance of a centre-fed clarifier. Two
indicators of cadmium contamination.
tion Research Journal of Canada, the re sults ofthe model simulations indicated
in both cases that clarifier performance is significantly affected by the unsteadi ness ofthe flow. A steady state analysis at the peak flow gave lower effluent con or the step increase in the MESS. Artificial Marshes for
Water Quality Control An artificial lake in the southern sector
of He Notre-Dame, Montreal includes a
lAWPR^^ Atmospheric Transport of Pollutants
In a joint Atmospheric Environment Service â&#x20AC;&#x201D; Freshwater Institute research
project, measurements of seasonally high concentrations of over 90 polychlorinated biphenyl congeners and over 30 organohalogen pesticides were analyzed by R.M. Hoff, D.C.G. Muir and N.P. Grift. The seven cases of high est concentrations of pesticide species all point to long range transport from the south, especially the southern United States and the Caribbean. The
concentrations of PCBs and organohalogens were strongly dependent on tem perature. The results published in En vironmental Science and Technology indi cate that modelling predictions of the
Biomonitors for Cadmium
tration, and a sudden increase in the MESS. As described in the Water Pollu
centrations than either the diurnal flow
tration of textile mills in the basin.
The objective ofa research study under taken by S. Ricard and coworkers at the
Modelling of Clarlfler Performance University of Windsor scientist J.A. McCorquodale and U.S. colleagues used a computer program to predict the effects of unsteady flow on the perfor cases were considered: diurnal varia tion in flow at a constant MUSS concen
Granby which has the largest concen
Three dyes were positively identified in addition to a mutagenic degradation product of one of them.
particulate
various periods oftime. At the end ofthe
parameters.
fifteen dyes in water, suspended solids
of
test periods various blood parameters were determined. Preliminary results indicate that the blood parameters, mainly the erythrocyte length to width ratio and the proportion of thrombocytes. seem to be good quantitative
bubble diffused aeration system. These scientists from the B.C. Ministry of En vironment and the University of British Columbia found that increasing the flow rate significantly increased the
Dyes in the Yamaska River A study ofthe Yamaska River in Quebec during 1985-1987 by R.J. Maguire and
concentrations
matter.
ters as bio-indicators of cadmium con
oxygen transfer in a pilot scale coarse
overall oxygen transfer coefficient and standard oxygen transfer rate, but only marginally increased the energy effici ency and the oxygen transfer efficiency. Decreasing the orifice diameter signifi cantly increased the values of all four
air
600 meter beach with a swimming area of approximately 15,000 mE In order to maintain satisfactory water quality, a "filter-lake" complex was established consisting of four ponds of varying
depth where aquatic plants of different native species were introduced. As des cribed to delegates attending the 27th Central Canadian Symposium on Water Pollution Research by G.Vincent of the Montreal Botanical Garden, in
take pipes draw water into the first marsh which then circulates by gravity through the three remaining marshes with substantial reductions in nitrate,
orthophosphate, ammonir.m, total phosphate,suspended solids, and filter able carbon.
Trace Metals In Drinking Water In a paper published in the Canadian Journal of Civil Engineering. Dayton & concentration of PCBs in air can be Knight scientists I. Singh and D.S. made knowing the vapour pressure, Mavinic of the University of British temperature dependence, and expected Columbia describe the results of their
WILLMS & SHIER/BARRISTERS & SOLICITORS Environmental and Waste Management Approvals, Municipal Law, Land Use Planning and Development,
For more information, Circle reply card No. 113 42
Environmental Science <& Engineering, July 1992
R&D News research on the signincance of building and plumbing specifics on trace metal concentrations in drinking water. The
published in the Journal ofEnvironmen tal Quality, were examined to assess the
influence of various factors on trace
level up to 600 mm increased the nit rogen removal efficiency. The domi nant micro-algae(Chlorhonttidium) was strongly influenced by the water tem
metal
perature.
contact with forest soil.
ion Enrichment In Forest Snowmelt
For more information,contact Dr. H.R. Eisenhauer, Canadian Asso
concentrations
in
first
flush
drinking water samples and "running" hot water samples was investigated. Lead was influenced primarily by build ing type, copper by plumbing age and type, and iron by location. A substantial number of first flush samples exceeded regulatory levels, and there were even some such cases after prolonged flushing.
Forestry Canada scientists P.W. Hazlett
Lakes Watershed, Ontario. The results,
modifications to snowmelt water after
and N.W. Foster together with M.C. ciation on Water Pollution Re search and Control,Conservation English. Wilfred Laurier University, de termined ion concentrations in snow- and Protection, Environment Ca melt run-off. forest floor percolate, and nada, Ottawa, ON K1A 0H3, Tel: mineral-soil percolate collected in a to (819) 953-9365, Fax: (819) 953lerant hardwood forest at the Turkey 9029.
Retardation of Phosphorus Losses in Runoff
Phosphorus loading in surface water bodies due to runoff from cropland is a major water quality concern. Losses of water, soil and different forms of phos phorus from five runoff plots treated with polyvinyl alcohol(PVA)were com pared to losses from five untreated plots by University of Guelph scientists M.H. Marsh and P.H. Groenevelt. As des
cribed in the Journal of Environmental Quality, run-off and soil and phospho rus losses were reduced as much as 80%
during the first year after application of PVA. and by 40% during the second year. Corn grain yield was 12% higher than on the control plots. Contaminated Sediments in Lake St. Louis
Particle size distribution, geochemical
Ordering the most
up-to-date inforrnation
in the world
is as easyas ordering
composition, and concentrations of a number of heavy metals were deter
this.
mined in radio-dated cores from Lake
St. Louis by A. Mudroch and S.R. Joshi to assess the significance of the lake as a sink of contaminants transported through the St. Lawrence River. As des cribed by these National Water Re search Institute scientists in Revue des
sciences de i'eau. the concentration pro files of mercury in the cores indicated a continuous input ofthis metal along the southern shore of the lake. In contrast,
the mercury input into the northern part ofthe lake has decreased reflecting con trol of mercury losses implemented by industry over the past 15 years. Tertiary Treatment with Micro-Algae
J.B. Serodes and colleagues from Laval University evaluated design criteria for a pilot plant treating secondary munici pal effluents using filamentous bioflocculating micro-algae. Using a sequen tial batch reactor as described in the
Canadian Journal of Civil Engineering. the best removal rate was reached for
25% draw volume. At 20-22°C.up to four cycles per day could be achieved giving a removal efficiency of approximately 2 g of nitrogen per day per square meter of basin(200 mm deep)with negligible nit rogen residual. Increasing the water Enviromtiental Science & Engineering. July 1992
CISTI IS THE FASTEST WAY to find the most up-to-date scientific, technical, and medical information in the world.
A service of the National Research Council, CISTI helps Canadian engineers and scientists in industry and the public sector access vital information from a world-wide network of resources.
CISTI Information Specialists save you precious time and money because they're connected to the most current and complete information resources. They can pinpoint specific data with unmatched efficiency. For more information about CISTI, and our new "Urgent Services", contact; Canada Institute for Scientific and Technical Information
at (613) 993-1600 or fax (613) 952-9112. To get you the information you need while it's hot, we'll even deliver!
KtCCNtC
M National Research Conseil national Council Canada
de recherches Canada
Canada
For more information, Circle reply card No. 114 43
Industry Awards
ES&E editor wins Environment Canada's
top communications award The Publisherand EditorofEnvironmen
tal Science & Engineering. Tom Davey has won Environment Canada's top award for
environmental
communications.
The Minister of State for the Environ ment. Pauline Browes, announced the
awards at an open air ceremony on Scarborough Bluffs at the Guild Inn. Toronto. The minister said in the citation that
Tom launched the magazine in 1988 with
his son Steve.
It is now ack
nowledged as the leadingjournal ofits kind for environmental professionals." she said. In hercitation she noted that Tom was the first Canadian ever to win a J.H.
Neal Award from the American Busi ness Press in New York. Later he be came the first writer outside the United States to win a Schlenz Medal from the
Water Environment Federation in Wa
shington. DC. He has now won 35 awards for his writing, including a pre vious Environment Canada Award and national awards from the Canadian Business Press and the Canadian Sci ence Writers Association.
The magazine was launched at
Finalists were unaware of the results until the announcements. At the ceremony Tom Davey, left, is pictured with his guest John Elliott and ES&E Sales Manager Penny Davey,just before the presentation. STD Photo
Steve's initiative in 1988 and the whole
family became involved. Steve had pre viously worked for Southam as Manag ing Editor of Water & Pollution Control and Process Industries Canada. Steve is Past President of the Ontario Pollution
Tom received a handsome award car
ved from Canadian shield granite. For mer environment minister Tom McMil lan was the Master of Ceremonies. He told the audience that he had had an
Control Association,(OPCEA) and a
article published in the very first issue of
Director of the PCAO.
ES&E
Tom's wife Sandra, who has edited
many environmental studies for the University of Toronto, became Associ
when
he
was
Environment
Minister. The other fi nalists were Oldies 900
ate Editor. She too holds an award from the PCAO for her editorial work on the
CJVI Radio of Victoria. B.C.. and Wally Longul of TV Ontario. The Awards were presented on May
history book Recollections and has
25 by the Minister of State for the Envi
edited the PCAO Newsletter for some 15
ronment. Pauline Browes.
years. She has also organized over 50 conferences PCAO.
and
seminars
for
the
Their daughter Penny joined the ma gazine as Advertising Manager and re cently was elected a Director of OPCEA.
Tom has given papers at countless seminars ranging from a World Health Organization Symposium in Rome. Italy, in 1982 to international conferen ces in Canada such as 'Waterscapes '91' in Saskatoon where speakers from 21 nations attended. Additionally he has
given papers at Queen's University, the University of New Brunswick and at
ogy North of the Northwest Territories. In the category of Corporate Environ mental Leadership, the winner was S.C. Johnson Wax. of Brantford. Ontario.
The company has been consistently in volved in environmental projects, and has set the pace in our country by offer ing consumer products with reduced environmental impact, implementing
internal recycling programs, and sup porting environmental projects throughout Canada. The other fi nalists were: Northern
Telecom of Brampton. Ontario and In the Lifetime Achievement category, Petro-Canada of Calgary. Alberta. the winner was Dr. Ian McTaggartIn the category of Environmental Lea Cowan. of Victoria. BC. A renowned dership by a Municipality,the winner was wildlife expert, he is credited with mak the City of Richmond. BC. Richmond ing wildlife management a branch of has implemented environmental pro applied science. Dr. McTaggart-Cowan grams in its own operations and for city has made major contributions to envi residents. It is also purchasing land for ronmental understanding over his long environmental protection and a muni career,serving government, universities cipal trails system. and non-government organizations. The other fi nalists were: the City of In the Non-Profit Organization cate Baie-Comeau. Quebec,the Township of gory. the winner was the Environment Ernestown. Ontario, and the City of Youth Alliance, of Vancouver. BC. an
environmental organization set up and run by young Canadians to involve high school students in environmental pro
Hull. Quebec. The Environmental Science Fair Project
given many lectures at the University of
tection. The other fi nalists were: the Bruce
award went to Kim Nguyen of Prince Rupert. BC. for a study of the environ mental impact of phosphate-free deter
Toronto.
Trail Association of Ontario, and Ecol
gents.
AWWA and PCAO conferences. He has
44
Environmental Science & Engineering. July 1992
Higfilights of the Fenwick team, from left to right:
Through innovation, odr highly
Introdudag Fenwkk
Dominique Levesque, M.Sc.
qualified team has established
Laboratories...
Manager of Organics Thirteen years experience including five as chief analytical chemist with Environment New Brunswick.
L_
environmental testing for quality,
Dr. Julie Marr,Ph.D. Manager of Research Eight years experience, particularly in the
cost, sample size, and turnaround
area of shellfish toxins.
time;ideal for MISA and other
Robert Boss,B.Sc. Manager of Development
Thirteen years experience, developer of RCAp.
regulatory programs
originator and exclusive provider of the nationalh recognized Rapid ^hemkal Analysis mnnrnm fRCAn)
Dr. David Jomieson,PhD. Senior Scientist
Forty-one years experience including fifteen OS leader of a National Research Council
analytical chemistry group.
Shirley BdrgaC B.Sc.
imm
RCAp Inorganics Manager
Fourteen years experience, managing over 9
one million pieces of analytical data yearly.^E Sean Mullaly, B.Sc.
Vice President and General Manager Twelve years experience, currently President of the Canadian Association for " Environmental Analytical Laboratories. Ross Kean, M.Sc. Manager of Inorganic Chemistry Fifteen years experience, seven as manager with the Ontario Research Foundation.
Dr. Ross McCurdy,Ph.D. President
Twenty years experience, professor and^^jg researcher at Dalhousie University omjQOH Technical University of
r
^
new industry standards in
nstitute of Conodo (f
fenwick is a full-serviqmp^mm
^rter Member
iabaratory,providing comprehensf
for Cnvironmei^^^^595 Fenv&l^l^
l^v certified/n a£^y^nlifox. Novo SciHif ^din the CAE^^^tamdu,B3H 4M2 . ^L. '^•^fBlfi nrrf
organic and inorganic analytical; services.
_
For more information, Circle reply card No. 115
^uite
;—
I t A I t A t ^ AI I i A i i > I I A t . I * i i i I I A i
Occupational health & safety
Use of health risk assessment In the
management of environmental liabilities sures are within safe levels.
As a minor component, health risk assessments may also include at least qualitative consideration of other ef fects of environmental contamina tion of fi nancial concern, such as
damage to property (for example cor rosion of structures or land erosion
caused by vegetation loss in con taminated soil). In the U.S.A., such pol lution effects of economic concern are called "welfare effects".
Generally, health risk assessments
fall into one of three categories of scale, complexity and cost: • small in scale, qualitative, costing about Cdn $15,000/30,000;
• intermediate in scale, quantitative for exposure to a few indicator con taminants over the few most relevant
Diver entering confined space to check out zebra mussels problems — photo cour tesy Aquatic Sciences.
There are many instances when
private clients or government agencies would like to have a quantitative estimate ofthe de gree of risk of a particular set of cir cumstances to human health. This is
government agency or an independent consulting firm,to avoid any question of conflict of interest. Risk assessment can be conducted to
risks due to environmental contamina
sures from the news media. It is often
important for a business with such cor porate stakes to see that an exercise in risk assessment is performed by an ob jective scientific organization,such as a 46
consideration of environmental fate
and transport pathways for a suite of significant contaminants, costing about Cdn $80,000/120,000.
These are only broad guidelines of complexity and cost. Each risk assess
meet a variety of specific objectives,
ment situation has to be evaluated in
such as:
dividually, and customized for appro priate scope and budget. In general,the procedures used follow the approach of the United States En vironmental Protection Agency, which has led the world in the development of
particularly the case when assessing the • to determine the degree to which an adverse health impact is reduced by potential impacts associated with expo employing various environmental sure to hazardous agents in the environ clean-up options at a contaminated ment, mainly chemicals or radioactive site; materials. Such a quantitative risk esti mate is called a Human Health-Based • to develop a clean-up criterion for a contaminant in a particular environ Environmental Risk Assessment and mental medium (such as soil, air or may estimate past, present or future ex groundwater) where a credible clean posures and the likely resulting hazards up criterion does not exist; or to health. Such health risk assessments are then • to develop a less strict, site-specific clean-up criterion, based on reason considered together with cost, technical able and prudent scientific reasoning, feasibility ofclean-up and other societal when the criterion in general use is pressures to select preferred strategies not practical for implementation. for managing or remediating health tion. It is important that the scientific process of risk assessment and the re lated but different process of risk ma nagement be kept separate, preferably performed by different parties. A corporation can have a variety of stakes in managing an environmental liability, such as public image as a cor porate citizen, trust in its products or services, tort liability,clean-up orders or prosecutions by government or pres
environmental transport pathways, costing about Cdn $35,000/50,000; or • large, fully quantitative, complete
Usually a baseline risk assessment is
performed first, estimating the risk to health ifthe site is left in its current state,
the methods of risk assessment. The use
of these quantitative risk assessment methods is widely required by US regulations. In Canada, risk assessments are not
driven by regulation, but a variety of private and public sector stakeholders are realizing the value of supporting a risk management decision with a risk assessment, based on reasonable, pru dent assumptions and sound scientific principles.The risk assessment approach in Canada is presently able to be more creative than is permitted in the USA, where acceptable procedures are fairly standardized and legislated.
that is, the "do nothing" clean-up op tion. From there, the effects of applying different clean-up technologies or of cleaning up to various levels of cleanli Health and Welfare Canada is now ness can be estimated for comparison. considering the development of guide Conversely,the process can be run in lines for the conduct of risk assessments reverse, starting with exposure levels in Canada, but the drive to standardize considered safe, and reasoning back by is unlikely to gain strong momentum transport through environmental path until some Canadian jurisdiction be ways, to a level of contamination con gins to require risk assessment input sidered acceptable at the source (a into the decisions made by environmen clean-up criterion level). tal risk managers. Health risk assessment can also be
used to determine whether work expo
The first step in a health risk assess ment is called Hazard Identification
Environmental Science
Engineering, July 1992
By David A. Whaley,Ph.D., R.O.H., C.I.H. which involves ideniifying the most re levant contaminants of concern at a
particular site (usually chemicals or radioactives) and their likely sources of release. Examples ofsources would be a spill of fuel in the soil, emissions from an incinerator stack,or the discharge of untreated process wastewater from a factory into a nearby pond or stream. What then follows is a series of pro
skin), and showering (offgasing. caus ing exposure by inhalation), or is taken up by the roots of vegetables consumed by humans, or by the roots of forage or silage eaten by beef and dairy cattle or
based on the"weight ofevidence"classi fication system ofthe USFPA.This clas sification determines (qualitatively) how likely it is that a hazardous material could actually cause cancer in humans. Tests with bacteria or experimental animals may be suggestive, but do not prove that chemicals or radioactivity ac tually can cause human cancer. Of all the kinds ofevidence considered in such
a judgement, evidence coming directly from experience with humans is the most compelling, such as from an acci
cesses. described here as if all the needed data were available. However,
often the necessary information about a contaminant does not exist. This is
dental release to the environment,or an
where the creativity ofthe risk assessor is challenged â&#x20AC;&#x201D; to attempt the most rea sonable estimates of the missing infor mation. using information available for closely related toxic chemicals or radio-
unintended workplace exposure.There fore. a scientific judgement should be made as to how much weight to give the available evidence that a material may cause human cancer.
actives. Sometimes the information
It is widely acknowledged that the
exists, but is faulty or conflicting, requir ing careful scientific judgement to use
numeric estimates of risk derived from
the most credible information avail
by poultry which enter the human
able.
food supply. Each potential pathway should be evaluated for its relevance to a par ticular site. The most relevant pathways for a site are selected by weeding out those pathways which could not have a significant impact under the cir cumstances at that site. Where possible, this weeding out process should use cre dible quantitative information. For each remaining important environmen tal pathway, the potential exposure for
this process contain some uncertainty. At present, risk assessments are expec ted to provide a feel for how dangerous a situation is. within an accuracy of about 10-fold to 100-fold. So much key infor mation is unknown or only approx imately known at this time, that this degree of uncertainty in the values es timated is presently considered accept able. The current approach is to use a series of conservative assumptions throughout the process, to intentionally overestimate the risk. It is felt that, using this approach, if the level of risk cal
Once the contaminants of concern are identified, the health risk assess
ment proceeds to the next phase, called the Toxicity Assessment which deter
mines the following information for each contaminant;(1) the most impor tant toxic effect to appear at low expo sure levels and(2)the minimal exposure level to cause this toxic effect. From this
information.(3) a safe exposure level is then estimated for that contaminant.
Currently, such toxicity information is handled somewhat differently, depend ing on whether the contaminant ofcon cern is able, or is not able, to cause can
cer.The results ofthe toxicity assessment are inherent to the toxic materials being considered, and will not be different from site to site.
The next portion of the risk assess ment is called the Exposure Assessment. which is site-specific, that is. developed uniquely for a particular contaminated site. First, the most susceptible nearby individuals, called the "critical recep tors". are identified. Examples ofcritical receptors are nearby people, for exam ple. who live just outside the property boundary of the contaminated site. Other critical receptors could be highly susceptible persons,such as very young, elderly or sick people. Secondly,from each identified source ofcontamination,all possible pathways by which each contaminant of concern can move through the environment to expose a critical receptor person are identified and evaluated.
An example of a potential environ mental pathway could begin from con tamination of groundwater with oil from a leaking underground storage tank. The contaminated groundwater is then taken from a well for use as drink
ing water(exposure by ingestion). bathing(exposure by absorption through the
each contaminant of concern to each
culated is judged to be acceptable.'then
critical receptor is estimated quantita tively. The last portion ofthe risk assessment
conclusions, because of the conserva
is the Hazard Characterization, which
risk estimate.
we are reasonably confident with the
tive assumptions used to develop this However,as the science of health risk
At present, risk assessments are expected to provide a
feel for how dangerous a situation is
combines the exposure estimate with the toxicity information to arrive at an over-all estimate of risk. For each con
taminant of concern, the exposure to one or several critical receptors by all pathways are combined, and compared with the safe exposure levels, as pre viously determined by the toxicity as
assessment matures, we are already see ing considerable refinements, such as better information on toxicity. and on environmental fate and transport, assis ted by computer modelling. These new developments are enabling risk asses sors to approach progressively more ac curate and realistic estimates of risk.
For completeness, there is a second type of risk assessment, which evaluates the impact of an uncontrolled release or environmental contamination on wild life and its habitat. This is called an
ecological risk assessment. The science
sessment. The hazard characterization
ofecological risk assessment has not yet developed as far as the science of(hu
is specific for the site and provides the findings, generally quantitative, upon
often employed in a rigorous fashion.
which are based the fi nal conclusions of the health risk assessment.
A thorough risk assessment should include some key qualitative informa tion.such as the degree ofscientific con
man)health risk assessment, and is less The U.S. Environmental Protection
Agency has developed a Guidance Manual,forecological risk assessments. In Canada, many risk assessors antici pate that ecological risk assessments
fidence which the risk assessor has in
will be an area of future interest and
the quality of the information available to him to perform the risk assessment.In the case of cancer-causing materials, a
development, but at a slower rate than the anticipated rate of growth in health risk assessment. ES&E
qualitative classification should also be
For more information,
made for each contaminant of concern.
Circle reply card No. 250
Environmental Science & Engineering, July 1992
47
GLOBAL COMMITMENT
TO QUALTTY & SERVICE leader in the field of geotechnical engineering for more than 30 years, Colder Associates
has, during the last decade, developed an extensive range of environmental services.
Our new corporate logo, an expansion of the established symbol, reflects these
broader capabihties as well as geographi cal expansion - to 50 locations in North America, Europe and Austraha.
In a related corporate development. Colder Associates Ltd. has identified an Environmental Division. Our
success is based on delivering services from a network of local offices, but we recognize the advantages to our clients of providing focused and fully integrated environ mental services. Divisional structure wiU help us to use our extensive professional resources more effectively in responding to our clients nationally and internationally.
, Golder
We shaU maintain our commitment to service and
Associates
quality as we serve our cHents' needs in the future.
Offices throughout Canada, the United States, Europe and Australia. MISSISSAUGA
2180 MeadowA'ale Blvd., Mississauga, Ontario L5N 5S3 Tel:(416) 567-4444 Fax:(416)567-6561
For more information, Circie repiy card No. 116
VANCOUVER
224 West 8th Avenue, Vancouver, B.C. V5Y 1N5 Tel:(604)879-9266 Fax:(604)879-5014
The Globe's timely mea culpa
The Globe & Mail has been a venerable
media
institution
for some 150 years and worthy to be ranked among the world's
great newspapers. Courage and fairness have always been Globe attributes, but now one might add a rare commodity in newspapers — humility. The Globe is not above a little self
Focus on real issues ing editorial. Where coverage on PCBs is concerned, the Globe repents freely and does not spare itself from critical Bravo for the editorial The Media's Ecofailure. It is very seldom that a news self analysis. The editorial drew plaudits from paper takes the time to question its own stories, and The Globe and Mail is to be Douglas Langley, President of Environ congratulated for doing so. ment Protection Laboratories. This edi torial, and Mr. Langley's letter are re Issues such as PCBs, incineration of produced below. wastes, dioxins and so on have been
deprecation as instanced in the follow
generally overblown and have deflected political and economic attention away from far more serious environmental
and social problems.
THE GLOBE AND MAIL CANADA'S
NATIONAL
Nfi-WSPAPER
The media's eco-fallure
Metals such as mercury, which have killed many and maimed thousands, are routinely found in our fish and food stuffs. Lead is known to be present in Toronto's tapwater, as well as in various foods, and its impact on the develop ment ofhuman intelligence is becoming well established. Chloroform — a mam
This newspaper has often criticized gov ernments that hurl public money at envi ronmental problems without sufficient study. We have been equally harsh with environmentalists who prod govern ments into hasty action with shrill warn ings and skewed information. What we have rarely done is examine the third culprit: ourselves. The news media's role in fuelling un founded environmental fears was under
lined last week by a landmark court judgment on urea-formaldehyde foam insulation. In dismissing the compensa
than try to determine the veracity of what they hear — as deadlines approach and editors scowl — reporters seek reaction from the accused party (usually a gov ernment or company) and print it along with the accusation. This Is known as objectivity.
ran 222 stories on the health risks of
UFFI in their houses, Mr. Justice Ren6
smoking,a habit that killed 38,357 Cana
Hurtubise of the Quebec Superior Court said that media organizations were as
dians In 1989.
much to blame as consumer activists for
That Is precisely the problem: the media deplore uncertainty. Mired in lazy habits, we prefer the cut-and-dried to the complex, the cry of outrage to the cau tious rumination. "Scientists unsure about health effects of UFFI" makes a
pallid headline. "UFFI home residents claim vomiting, headaches" makes page
This failure of perspective Is most ob vious in environmental accidents. When
a truck carrying leaky transformers spilled oil laced with PCBs along the Trans-Canada highway In 1985, news papers gave the story banner treatment. Many people were frightened and the government spent millions repaving the road. Surely this would have been the time to put the dangers of PCBs into focus. To their credit, some newspapers tried. Not hard enough. Six years later, governments are spending tens of mil
Douglas Langley
lions of dollars to remove PCBs from
sites across the country,largely because of unfounded public fears.
one.
None of this means that the media
Realizing this, many environmentalists have learned to serve up clear, unam biguous opinions, preferably couched In terms of an angry accusation. Rather
How many environmental stories has The Globe and Mail(or any other major paper) published about these com pounds? The public would be better ser ved by having attention focused on the problems that really exist and really af
So it is that The Globe and Mall pub lished 386 stories in the past six years about polychlorinated biphenyls, a family of substances whose only proven health effect is to cause acne, eye dis fect human health,rather than on PCBs charges and vomiting in people who in and dioxins, whose human impacts are gest\hem.In the same period.The Globe . either not documented or are trivial.
tion claims of homeowners who used
whipping up hysteria about the risks of UFFI — risks which he found unproven. "The physical and chemical effects of UFFI," said Judge Hurtubise, "remain the object of speculation and uncer tainty."
malian carcinogen — and other trihalomethanes are found in drinking water of most Ontario municipalities, often at levels higher than U.S. or World Health Organization guidelines.
should Ignore genuine environmental threats. It Is our job, however,to maintain a sense of proportion. So far, we are falling.
Environmental Science & Engineering. July 1992
The Globe and Mail has taken a bold
first step in recognizing its lack of per spective in printing environmental stories. We look forward to seeing an emphasis on the real environmental issues.
D.G. Langley President, Environment Protection Laboratories, Inc., Toronto 49
Water treatment
By Bob Stevens*
New standards for testing water fittings for toxicity
For many years, water supplies
in the United Kingdom were conveyed in traditional ma terials such as clay pipes and copper and brass tube. Joints were sealed with hemp,pitch,and solder.The
behaviour of these materials in contact
with water was quite well understood,at least to the level of toxicity awareness. National standards were established for
metal fittings in contact with water to ensure uniformity ofsize and durability and safety in use. The post-war years have seen enor mous changes, with plastics and pet rochemical products now being used for purposes that previously only tradition al materials could serve. Among these uses have been replacements for copper
and other metal piping systems,flexible hoses, plastic reservoir liners, valve bodies, washers, gaskets, sealants, and adhesives.
The novelty of these replacement ma terials means that they have no "track record" of safety as they have not been previously tested.The harmful potential of untested materials is great. For in stance, one fatal outbreak of Legion naires' disease in the U.K. has been
Materials testing In many countries,includingthe U.K.
and the United States, work has begun on testing and approving for use the many different items and formulations
The novelty of these replacement materials means that they have no "track record" of safety
traced to the growth oflethal bacteria on of nonmetallic materials for water ap the surface of nonapproved rubber gas kets in a hot water system. Furthermore, plications. In the U.K.,the end result is a the list of possible additives in these British Standard (comparable to the replacement materials runs to several American National Standards Institute pages,so that it is not feasible to approve [ANSI] standard in the U.S.), known as any intended application solely on the BS 6920 of 1990.This standard describes the tests which must be applied and ways of conducting them for a material to receive approval for use and subse quent entry to a national approved list of fittings. One of the first to be involved, Clay ton Environmental's U.K. laboratory is
basis of written details.
now one of three approved laboratories in the U.K. conducting this testing. Some 800 water fittings products are examined in the U.K.each year,at a cost
of around 800 pounds sterling per pro duct. The testing takes about 10 weeks, and is planned to simulate the con ditions which the material will encoun ter in its end use. The tests include:
• Taste and appearance of water after contact with the product • Growth of aquatic microorganisms • Cytotoxicity testing • Extraction of potentially toxic metals
Taste and appearance. Although listed first, this test is actually performed last, only after all other tests have been satis fied. Volunteers in our Birmingham la boratory have been assessed for their
sensitivity to the principal types of water taint, which have agreed-upon descrip tive names — chlorophenolic, "pen cils," rubber, musty, and so on. From these volunteers, a panel of 12 has been identified. Every week or so they are asked to leave their normal work for an hour to taste and comment
on the range oftest waters.Ofcourse,the water is never swallowed, and it is not
even tasted if there is any noticeable odour. Taste testing is done with the In-
*Public Analyst/Analytical Laboratory Head, Clayton Environmental Con sultants, Birmingham, England. The old and ne\w. Striking modern water tower combines aesthetics with efficiency in Metro Toronto. Gore & Storrie designed this water tower storage project. 50
continued overleaf
Environmental Science & Engineering. July 1992
WET OR DRY, FLYGT KEEPS PUMPING IT OUT. Flygt's wet CP pumps are easy to install. They can be mounted quickly and simply on guide bars and lowered into the liquid. The discharge connection is fixed to the sump floor so that when the pump is lowered on the guide bars, it automatically engages the discharge connection and releases automatically when it is raised.
Flygt's dry CT pumps are installed alongside the pump sump and mounted on a stand with inlet pipes. Like all Flygt pumps, they are submersible and cannot be damaged by accidental flooding.
All of our C pumps are compact, efficient, and available in sizes from 1 to 700 HP.
Backed by years of application engineering experience, they can reduce operating costs by up to 75%. They provide reliable perfor mance and the peace of mind you have come to expect from Flygt.
For complete information on our versatile C pumps,contact your local Flygt representative. Good Ideas Take Flygt. For more information, Circie reply card No. 127
Flygt
inniifTni
ITT Fluid Technology Corporation FLYGT CANADA,300 Labrosse Ave., Pointe-Claire, P.O. H9R 4V5 (514)695-0100 Telex: 05-821844 Telefax:(514) 697-0602 Vancouver•Calgary » Edmonton ■ Saskatoon ■ Winnipeg ■ Hamilton ■ Etobicoke ■ Sudbury ■ Ottawa ■ Pointe-Ciaire ■ Quebec ■ Vai d'Or ■ Moncton ■ Halifax ■ St. John's (Nfld.) USA: FLYGT CORPORATION, Norwaik, Conn.
Waterfittings cont'd Experience The Versatile
Classifieds
Bentomat
Bentonite Geocomposite Liner
Easy to Install Budget Priced
CARBONITE FILTER MEDIA
Landfilis, Ponds, Lagoons Tank Farm Containment BEMALUX, INC.
ANTHRACITE FILTER MEDIA
also suppliers of quality filter sands and gravel
Tel: 800-361-1939
ANTHRAFILTER MEDIA & COAL LTD. ^20 Sharp Rd.,R.R.#6, Brantford, Ont. N3T 5H6
Fax:(514) 332-0132 London, Toronto,
Tel:(519)751-1080 Fax:(519)751-0617
Sudbury, Montreal
ternational Standards Organization (ISO)wi ne tasting glasses,but no one yet has spoken of a water with "a preten tious nose belying its humble origins and relative youth." Not everyone has the required sen sitivity or ability to discriminate,and the job is complicated by the fact that we all tend to show an in-built preference for the water we grew up with. People who grewup with hard water find it more dif ficult to spot problems when the water tested is from Birmingham's soft water supply! Growth of aquatic microorganisms. This test assesses whether any sub stance can leach out ofthe material that
will encourage bacteria to grow on its surface. In the test, a portion of the test material is incubated in a bottle con
taining tap water and an inoculum of river bacteria. SLUDGE SLU MANAGEMENT
LI
Complete Digester
SEPARATION SPECIALISTS
and
SOLID
Lagoon Cleaning
KOMLINE-SANDERSON LIMITED
Land Appiication Systems
BRAMITON ONTARIO lewiwl
(AI6|A5]-S3]0
Program Development
noNr\tnRto TECHNICAL
SERVICE
COMPLETE FLOW MEASUREMENT APPLICATION • DESIGN • RETROFIT •INSTALLATION • ACCURACY•
temporary &
"MISA" Spec Applications Support
The test is conducted in our microbiol
ogy laboratory, using cell cultures in petri dishes. Microscopical examina tion of the cells shows whether they are being adversely affected. Extraction of potentially toxic metals. The test measures levels of aluminium,
Tel: (416) 648-3463 1435 Jerseyvllle Rd. W., Jerseyville, Ontario LOR IRQ
Flow Meter Calibration
Cytotoxicity testing. This test assesses whether any chemical is leached out which is damaging to mammalian cells.
permanent
63 Mclntyre Place KItctiener, Ontario N2R 1G3 (519)748-8024
antimony, arsenic, barium, cadmium, chromium,iron, lead, manganese, mer cury, nickel, selenium, and silver which might have leached into water from coming in contact with the water fitting. This testing is performed using atomic absorption and inductively coupled plasma instrumentation. In each case, maximum permitted levels of metals lost to the test water are set by the British standard.
The British standard is quite similar to ANSI 61 in the U.S. To date, we have
not tested any samples using the U.S. standard, although we have used the British standard ofU.S.customers wish
SALES • SERVICE • RENTALS
Environmental Specialists
N^M INSTRUMENTS LTD.
Wastewater Samplers Groundwater Sampling Level Control & Flowmetering Plant Air Clean Up Portable Test Equipment: pH, Turbidity
Suspended Solids,'02, DO, Conduotivity
2495 Haines Road, Mississauga, Ontario L4Y1Y7,Tel (416) 277-0331, Fax (416) 277-2588
D.S.I.L. Drilling Inc. (drilling contractors) • Monitor well installations
• Angle borehole capabilities
• Mineral exploration • Geotechnlcal applications
• Instrument Installations
"Serving Eastern, Central & Western Canada Since 1956" Tel: (416) 751 -6565, Fax: (416) 751-7592
ing to sell their products in the U.K.Test ing against the ANSI standard is an area we intend to explore this year. Conclusion
With increasing frequency, the com mittee that approves water fittings is asking for analysis for particular toxic or potentially toxic compounds in water,depending on the composition of the plastic used. This field of testing is very sophisticated, requiring gas chromatography/mass spectrometer (GC/ MS)facilities to be used. With the formation of the "Internal
Market"in Europe,work is underway at Centre Europeene pour Normalisation (CEN), the European equivalent of ANSI and the British Standards Insti
tute (BSl), to set one Euro standard for
testing water fittings. Of course, we be lieve the British way is best and will seek to persuade our partners to adopt it. ES&E
52
Circle reply card No. 257
Thank you
We wish to thank all of our
customers for their continued support. We appreciate working with clients who understand the
benefits of quality analytical data, delivered on time at competitive fees.
ENVIRONMENT PROTECTION
LABORATORIES INC.
6850 Goreway Drive, Toronto, L4V IPl, Tel: (416) 673-3255, FAX:(416) 673-7399
„ Engineering, r- ■ T , 1992 mm Environmental Science & July
For more information, Circle reply card No. 128
53
Solid waste management
Waterloo recycling centre meets material diversion objectives overall recycling efforts. The facility in corporates a floor area of 3,500 m^, ex cluding administration and Table 1 breaks down the material types and quantities processed. The MRC is designed to receive all materials inside the building. Separate
receiving/storage areas are provided for
/GLASS STORAGe/
newspaper, OCC, telephone books, mixed paper, source-separated glass and commingled material. Each of
[ STCRAGg/
these streams has a dedicated truck door
for access to the tipping floor area. Newspaper and OCC are separately front-end loaded from their respective tipping areas directly onto the baler feed conveyor. Contaminants are removed by hand prior to loading the conveyor. The bales produced are stored in the building, or are loaded directly into waiting transfer trailers, prior to ship
BALE SrORACE /
/FWE PAPEft SORTING/
ment to market.
The source-separated glass and com mingled materials undergo processing via their respective conveyor systems. The processing of curbside coloursorted glass focuses on contaminant removal, while processing of the com mingled stream includes contaminant removal,colour-separation of glass, fer rous and aluminum cans removal, and
GENERAL ARRANGEMENT PLAN
The Regional Municipality of Waterloo Material Recycling Centre (MRC) is designed to
receive, process, store and ship "blue box" material from single and multi-family residential units and apartments, and industrial,commercial and institutional recyclable materials, including corrugated cardboard(OCC) and, in the future, mixed office paper. Blue box
was completed in February, 1991. The facility was officially declared "open" May 31, 1991 by Ontario Environment Minister Ruth Grier. The official open ing featured local school children par-
colour-sorted glass is being processed, the operation is primarily restricted to contaminant removal. After separation, the sorted glass is conveyed to indivi-
tems and MacViro Consultants Inc.
In the case ofthe former, when curbside
materials include source-
separated newspaper including OCC and telephone books, curbside coloursorted glass, and a commingled compo nent comprising ferrous cans, alumi num cans,plastic containers and, mixed glass. The Materials Recycling Centre is owned by the Regional Municipality of Waterloo and is operated undercontract by Laidlaw Waste System Ltd. The building and building services were de signed by Reider, Hymmen and Lobban Architects and MacLaren Engineers Inc., while the processing equipment selec tion and layout were designed and com missioned by Resource Integration Sys 54
Construction of the facility began in the fall of 1989 and was completed by the end of 1990. Start-up and com missioning ofthe processing equipment
plastic(PET)bottles removal. Colour-sorting ofglass is achieved by conveying the mixed glass past manual sorting stations. Provision for sorting clear, coloured and mixed broken glass streams is provided for both conveyor lines;one handlingthe source-separated mixed glass, the other handling com mingled materials including some glass.
With over a year of operation now logged, the MRC has successfully met Its material throughput design rates and Is playing a key role In the Region's overall recycling efforts. ticipating in a clever recycling demon stration using the plant's equipment and set to music pointing towards the future â&#x20AC;&#x201D; "2001 A Space Odyssey". With over a year of operation now logged, the MRC has successfully met its material throughput design rates and is playing a key role in the Region's
dual roll-off storage containers located outside the building for delivery to market.
Separation of the ferrous, aluminum and plastic components of the com mingled stream is achieved by convey ing this material past a magnetic sepacontinued overleaf
Environmental Science & Engineering. July 1992
LIQUID CARBONIC BREAKTHROUGH TO CONTROL EMISSION POLLUTION
MEET CLEAN AIR COMPLIANCE AND GENERATE ADDED INCOME The new Liquid Carbonic Vapor Recovery System safely reduces emission pollution at point of transfer. With this new technology you get a host of advantages: ■ Low capital investment ■ Recovery of valuabie chemi cals to improve your cash fiow ■ Fast response to changing
petroleum liquid terminals
Use the coupon below to get details on Liquid Carbonic's advanced soiution to vapor poilution.
and tank farms,
manufacturing and process ing plants using soivents, and soivent manufacturing plants.
LIQUID CARBONIC VAPOR RECOVERY SYSTEM FLOW SCHEMATIC
stream flow rates and RECUPERATOR
concentrations ■ Economical and
easy operation ■ Low power requirements ■ Low maintenance—replacing expensive adsorber/absorber
SECONDARY SEPARATOR
VAPOR LADEN |& GAS INLET
LN2 CONTROL
beds is eliminated
VALVE
■ Fast instailation
■ Pure cooiing/recovery medium—nitrogen —that doesn't pollute the air Soive emission pollution probiems at ■ chemical terminals and
CONDENSATE DRAIN
GASOLINE/CHEMICAL IICAL STORAGE TANK
CHEMICAL REACTOR
»
tank farms,
Liquid Carbonic Inc. 255 Brimley Road Scarborough, Ontario M1M 3J2
Telephone:(416)266-3161
For further information, write for Form Number 6898 Vapor Recovery Brochure Attention Department ADV,
Liquid Carbonic Inc. 255 Brimley Road Scarborough, Ontario M1M 3J2
NAME
TITLE
COMPANY
TEL.
ADDRESS
CITY
PROV.
POSTAL CODE
LIQUID CARBONIC
PRODUCTS PRODUCED
LIQM161 RC
For more information, Circle reply card No. 129 Environmental Science & Engineering. July 1992
55
Solid waste management con't rator and manual sorting stations on a dedicated conveyor system. The ferrous material is collected using an overhead rotating belt magnetic separator. Fer rous cans, after magnetic separation, pass through a can flattener for volume reduction before being conveyed to a roll-off container located outside the
building. Aluminum and plastics are separated from the commingled stream by manual sorters. These separated materials are dropped into chutes then conveyed to portable storage cages lo cated inside the building. Plastic bottles are passed through a perforator prior to being caged. The perforator increases the storage capacity of the cages and ultimately improves the bales produced. When sufficient quantities of alumi num and plastics have accumulated,the respective cages are rolled to the baler feed conveyor and the contents dis charged onto the conveyor for baling. Although ferrous baling was not origin ally intended, if the ferrous market dic tates, the roll-off storage container is delivered into the building and its con tents unloaded onto the baler feed con
veyor for baling. Presently ferrous material is being baled. The heavy duty baler features an elec tric eye in the feed hopper to initiate bale production and an auto bale tying me chanism for hands-off operation. All
floor sorting operations. The control console is equipped with a programm able controller, programmed to start and stop equipment with the approp riate commands and in proper sequence. Light indication is provided for each piece of equipment on the console to denote status of operation. Adjustment of conveyor speeds(for those conveyors
state-of-the-art.
equipped with variable speed drives; namely the conveyors which pass by manual sorting stations) is from the control room as well. Local start/stop buttons are provided for each piece of equipment, allowing local overriding of the central control system. From the outset, numerous design features were incorporated into the MRC to ensure the facility is, and con tinues to be, state-of-the-art. Present
material quantities to be processed are such that primarily manual sorting is more
cost-effective
than
automated
TABLE 1
2010 DESIGN BASIS
tonnes/day
tonnes/yr
tonnes/day
tonnes/yr
tonnes/day
tonnes/yr
tonnes/day
News
8,546
34.2
11,503
46.0
9,000
36.0
7,712
443
occ
9.072
36.3
12,156
48.6
6,225
24.9
3.028
17.4
-
-
-
250
1.0
-
1991 EXPECTED
1991 ACTUAL(l)
1990 DESIGN BASIS
tonnes/yr
Mixed Paper
present and for the foreseeable future, several design features have been incor-
From the outset, numerous design features were incorporated into the MRC to ensure the facility is, and continues to be,
MATERIALS AND QUANTITIES PROCESSED AT MRC
MATERIAL
ing of the coloured glass component into "green" and "brown" streams if de sired.Space has also been allowed in the present layout to accommodate a second commingled conveyor sorting system, essentially doubling the plant capacity. Since manual sorting will be used at
-
-
Ferrous
1,139
4.6
1,.533
6.1
800
3.2
1,450
8.3
Aluminum
85
0.34
114
0.46
225
0.9
90
0.5
Plastics
285
1.14
384
1.54
125
0.5
83
0.5
Glass
2,563
10.2
3347
13.8
2,425
9.7
626
3.6
Totals:
21,690
86.8
29,137
116.6
19,050
76.2
12,989
74.6
porated to maximize operator efficiency. All sorting conveyors are provided with variable speed drives allowing optimi zation of speed settings depending on the number of pickers and the material mix. The variable speed capability also allows better control of conveyor mate rial depths which directly impacts sort ing performance. Spring loaded shear gates are provided on both the com mingled and source-separated glass feed conveyors to provide additional material depth control while minimiz ing breakage of glass. Other features in clude sorting platform height adjust ment, optional glass sorting techniques (hand picked or projection of glass against an impact plate using "pad dles"), and conveyor half-speed pedals at each sorting station. Operators can activate the half-speed switches when the conveyor burden depth becomes ex cessive. All of these features help to im prove the manual operations at the MRC,ultimately improving the overall operation's economics. Table 1 provides a breakdown of the materials processed at the MRC,includ
ing annual and daily tonnages. As shown in the table, total daily tonnages processed are comparable to the expec ted quantities established at the design phase. Processing totals for certain items have increased, while others have
(1) May through December, 1991(174 Processing Days)
decreased, reflecting changing market conditions since design was initiated in 1989.
baling system controls are located at the baler. The baler is operated indepen dently ofthe glass and commingled con veyor systems by a dedicated baler/forklift operator. Conveyor systems are manually oper ated from a control console located in
the process control room. The process control room is located on the mez
zanine level of the MRC, overlooking the conveyors. This arrangement pro vides clear viewing of the conveyor and 56
sorting. The equipment layout has been designed however to accommodate, in
With its first year complete,the MRC has successfully met its own recycling goals and is an integral part of the Re
the future, an air classifier for auto
gion's efforts to meet the Minister's re
mated plastics removal,an eddy current separator for automatic aluminum cans capture, and a vibratory screen for au tomatic separation of two size fractions of glass. Any or all of these features could be installed if future quantities dictate. In addition, the present glass sorting conveyor system will, with minor upgrading, allow for further sort-
cycling targets. The Regional Munici pality of Waterloo must be commended
for its initiative in developing this im portant project. Under the Region's leadership, the MRC's development by the private sector,including conception, design, construction and operation, provides an excellent model for others to follow. Circle reply card No. 259
Environmental Science & Engineering. July 1992
CETECH A two day conference on Environmental
Solutions for Canadian Industry October 20& 21,1992 Toronto International Centre
6900 Airport Road This two-day conference organized by Envi ronmental Science & Engineering Magazine features legal and technical experts who will focus on the formidable environmental com
pliance problems that confront industry mana gers and engineers daily.
Who should attend: Environmental Affairs Director
CETECH
Environmental Engineer Plant Manager General Manager Corporate Affairs President
Conference Topics □ □ □ □ □ □ □ □ □ □
Are You The Designated "Jaillee" Environmental insurance in Canada
Transportation of Dangerous Goods Indoor Air Quality and Outdoor Emissions
Conducting an Air Emissions Inventory A New CFC Recovery Technology Direct Industrial Discharges Pollution Prevention Strategies MISA, CAP and Safe Drinking Water Act Strategies for Hazardous Waste Management
□ High Efficiency Electrolytic Wastewater Treatment
□ Occupational Health & Safety □ Environmental Risk Assessment □ Could Backflow Contaminate Your Plant's Drinking and Process Water? □ Communications, the Achilles Heel of industry
Environmentally — what you don't know can hurt you Never before have senior industrial managers and engineers faced such formidable problems. Now, in
addition to complex economic and manufacturing situations, industries face increasingly stringent environmental regulations. Then there are air qua lity requirements inside the plant — as well as a host of occupational health and safety liabilities.
Expert advice can be expensive
— lack of it can be devastating
Environmental violators not only face heavy fines, but also jail terms. Yet, pollution abatement pro jects are sometimes prohibitively costly. To cope with the complexities of legal liabilities, compliance requirements and other factors, today's busy mana gers and engineers require the assistance of top experts from various disciplines. This conference delivers the experts — at a fraction of the cost of a consultation.
Technical Program (subject to change)
Environmental Science & Engineering magazine staff have put together a range of expert presenta tions — designed to help senior staff to cope with these issues.
This conference can help you avoid costly litigation, and perhaps even save money on process or other adjustments. For a fraction of the price ofa personal consultation, the presentations wiii enable you to hear and question some of the top experts in the country.
October 20, 1992 MORNING SESSION — Cost: $95.00 9:00 a.m. — 12:30 p.m.
Legal Liabilities — what you don't know can hurt you
Liability Issues In The 1990's Are You The Designated "Jaillee" The Beta case and its implications. This precedent setting case has far reaching impiications for ailsenior management people. The sentencing decision was unusual, both in the relative seve rity of the fines and particularly in the fact that the corporation was forbidden from indemnifying the two directors for the pay
MISA, CAP and Safe Drinking Water Act — How They Affect Industry Environmental regulations have been evolving in Canada over the past decade. There are great cycles of activity in the envi ronmental regulatory field, followed by more relaxed periods. The ebb and flow Is tied to economic reality, and to prevailing government's determination to regulate. This paper wiii review the current status of IVflSA, CAP and the Safe Drinking Water Act and other proposed provincial regulations; as well as some of the emerging federal legislation on environmental manage ment.
James N. Bishop, B.Sc. — vice president. Environment Protection Laboratories, formerly director of Water Resources, Ontario MOE.
Transportation of Dangerous Goods: The Regulatory Maze The transportation of dangerous goods is heavily regulated in Canada and there is considerable overlap In jurisdiction bet
ween the provincial and federal governments. This paper wiii provide an overview of the applicable regulatory frameworks and will address new and upcoming requirements imposed as a result of international agreements.
Speaker to be confirmed.
Lunch Break
ment of their fines.
Roger Cotton, LL.B., LLM.— partner and head of the Environmental Law Group at Fasken Gampbell & Godfrey.
AFTERNOON SESSION — Cost: $95.00 2:00 p.m. — 4:30 p.m.
Air Pollution Control
A Legal View of Environmental Insurance In Canada
The Blue Bottle — A Canadian
- Which policies apply at the time of an environmental "occur
Environmental Protection
rence" or loss?
- What coverage may be available under your comprehensive general liability policies? - What is the proper interpretation of pollution exclusion clauses?
- Does coverage extend to ciean-up costs imposed by statute? - Trends in American case law and the reaction of Canadian
Technology The Blue Bottle technology with world-wide patent protection facilitates capture and recycling of CFCs from both concentra ted and dilute emission streams. It has been developed to reduce CFC emissions to "zero" and to provide 100% recovery yield of high purity product suitable for direct reuse.
courts.
Data available from the first commercial scale trials to be car
- Future trends in Canada for insurance protection from envi
ried out in collaboration with SEARS and TRANE Engineering Service Agency wiii be discussed.
ronmental risk.
Bruce Smith, LLB. — partner, Blake, Gassels & Graydon.
Dusanka Filipovic, P.Eng., and Michaei Hirtenstein, Ph.D., Haiozone Recycling inc.
Free trade show pass Discover the latest technology, products, and services for prevention, minimization, control, handling and management ofpollutants at the CETECH exhibition. CETECHis a special exhibit section ofPMDS — Cana da's largest Plant Management & Maintenance/De sign Engineering Show. Over 10,000 industry person nel and 500 exhibiting companies attended PMDS in 1990. Registered conference delegates receive a free pass to the trade show.
Sources and Occurrence of
Indoor Volatile Organic Compounds (VOCs) increased awareness of the importance of indoor air quality (lAQ) has fueled much of the research over the past 10 years. The need to identify and measure airborne V^OCs in indoor environments because of potential deleterious effects on human health has been demonstrated. A variety ofindoor sources can emit a wide range of VOCs,some of which are potential irritants
and cause discomfort or more serious toxic effects. For the
investigator, understanding VOC sources, the character of emissions and their fate, can help solve lAQ problems.
Philip Feiiin, M.Sc. — principal and director. Concord Environmental.
Conducting an Air Emissions Inventory
Who should attend: Environmental Affairs Director
Environmental Engineer Plant Manager General Manager Corporate Affairs
The requirements for plants and manufacturing facilities to account for all their waste products are constantly being tighte ned. Until recently, most plants were required to account for their air emissions of contaminants on a per source and, typi cally, one time basis. This procedure was, in Ontario, handled through the familiar Certificate of Approval process, instituted many years ago by the Ministry of the Environment (MOB). Regardless of these regulatory initiatives, every industry should know what its atmospheric releases of materials are at any time, in this way, the degree of compliance with current regulations, and the impact of intended changes can be assessed. Any remediation work needed can then be done efficiently.
President
Alan D. Church, C.Chem. — environmental management consultant. Church & Trought inc.
Strategic Planning for Hazardous Waste Management
October 21, 1992
A review of critical issues facing any firm involved in planning a comprehensive, long-term strategy for managing hazardous chemical wastes. It aims'to address technical issues, including the selection of optimum treatment technologies and strategies
MORNING SESSION — Cost: $95.00 9:00 a.m. — 12:30 p.m.
Direct Discharge
as well as the economic factors involved in these decision
making processes, using the modern approach of "full-cost environmental accounting".
Bernard Fleet, Ph.D., M.Sc. — president. Toxics Recovery Systems international inc., and Adjunct Professor, University of Toronto.
Good Housekeeping Practices for Industry in the 1990's The purchase or sale ofindustrial property, or the expansion of an existing operation, frequently requires consideration that hazardous materials are present and the need for eventual site remediation. Sometimes the cost of cleanup can run into mil lions of dollars, implementing good housekeeping practices and practicing corporate due diligence now may help to mini mize clean-up costs in the future. The way existing industrial operations are managed can reduce, improve or compound the problems on site. Recommendations will be presented to assist with site specific business decisions including site planning, audits, operation, equipment purchase, and cost planning.
Reducing Environmental Impact: Is it a Waste? Many manufacturers and processors are facing tougher envi ronmental regulations, requiring expensive wastewater treat ment and solid waste disposal. Experience has shown that costs can be saved by altering the way processors look at their wastewater.
Water conservation, reuse, and the recovery of solids from wastewaters for reuse or feed to livestock, are examples of measures that reduce environmental impacts and costs.
George Crawford, P.Eng.
manager, industriai Wastewater Section,
Gore & Storrie Limited.
Ian McCiymont, P.Eng., and John Mcirvine, Ph.D., Proctor & Redfern Limited
Trenchless Pipeline Renovation — An Environmental Protection
High Efficiency Electrolytic Wastewater Treatment Test results and applications of this world-wide patented process for a wide variety of industrial wastes will be demons trated. The successful destruction of chlorinated benzenes and
PCBs is covered, together with the ESi closed-loop system for discharge-free operation. The importance of by-product hydro gen is referred to as a means of further reducing operating
Strategy Renovating service and process pipelines, especially those underground, is an important economic part of an environmen tal protection strategy. Over time, a leaking pipeline can cause widespread ground contamination leading to costly soil ciean-up. No-Dig renovation techniques such as deformed polyethylene liners, provide a new option for prevention and repair.
Ian J. Doherty, P.Eng. — technicai director, Samuel Pipe Liners, inc.
costs.
Michael E. Neaie, M.Sc., C.Chem., MRSC.(U.K.) — Effluent Strategies inc.
Lunch Break
AFTERNOON SESSION — Cost: $95.00
Communications, the Achilles
2:00 p.m. — 4:30 p.m.
Heel of Industry
Occupational Health & Safety
Environmental communications have become theAchiiies Heel
Environmental Risk Assessment Based on Human Health Industries or government agencies often need to have a quanti tative estimate of the degree of risk to human health in a particu lar scenario of exposures to hazardous agents, such as chemi cals.
of commercial enterprise, with perception dominating reality in today's media coverage. The paper wiii cover the basics of communications, including writing press releases for both marketing and other media announcements.
Tom Davey, publisher. Environmental Science & Engineering magazine.
Such an estimate Is called a Human Health-Based
Environmental Risk Assessment. A Risk Assessment may esti mate past, present, or future exposures and likely resulting hazards to health.
About the organizers
David A. Whaiey, Ph.D., R.O.H., C.i.H., D.i.H. — environmental and industrial hygiene toxicologist.
This conference is sponsored by Environmental Science &Engineering magazine. Over the past 17 years, ES&E staffers have organized numerous conferences and seminarsfor the Pollution Control Association of Ontario, the Air and Waste Mana gement Association and Environment Canada, on pollution abatement, waste management and environmental legal affairs. In May 1992, Tom Davey, the magazine's publisher, was presented with Environment Canada's top award for envi
Your Plant Water System; Is it Safe? The water within your plant's distribution system should be both safe to drink and of high enough quality for processing requirements. Many case histories are on file where contamina tion of a product or sickness has occurred due to use or consumption of water that has become unsafe. Cross-connections within your plant's water system can allow such things as gasoline, anti-freeze, arsenic compounds, or even propane gas and wine to enter your supply piping.
ronmental communications.
Michael Birks — manager, Febco |Canada|.
HOW TO REGISTER: To register for the conference, please fill in and return the registration form below. For further details, contact Steve Davey (416) 727-4666. (Canceiiation deadline: October 12, 1992.) Price:
One Session
-$ 95.00
Three Sessions -$195.00
Two Sessions
-$150.00
Full Registration - $240.00
(GST included) (GST #122654049)
Note: Second delegate from each company receives a 50% discount.
Please fax or mail this form to Environmental Science & Engineering, 10 Fetch Cr., Aurora,ON,L4G 5N7, Fax:(416)841-7271. Please make cheques payable to Environmental Science & Engineering. Name:
Company:. Address:—
Phone:
Fax:.
Please register me for the following sessions: □ Legal Liabilities □ Air Pollution Control □ Occupational Health and Safety Account Number:.
□ Direct Discharges □ Cheque enclosed □ Please invoice □ VISA:
. Expiry Date:
.Signature: .
THE ENVIRONMENTAL SOLUTION FOR CANADIAN INDUSTRY DISCOVER THE LATEST ENVIRONMENTAL
TECHNOLOGY, PRODUCTS AND SERVICES FOR
CANADIAN INDUSTRY AT CANADIAN
CETECH
MANUFACTURING WEEK
OCTOBER 20-22, 1992 TORONTO INTERNATIONAL CENTRE
CETECH is a special environmental exhibit section of FMDS — CANADA'S largest Plant Management& Maintenance/Design Engineering Show.With over 700 exhibiting companies and four shows at Manufacturing Week,this is a "Must Attend" event for engineers, consultants and other environmental decision makers.
A two-day conference organized by Environmental Science & Engineering Magazine features legal and technical experts who will focus on the formidable environmental compliance problems that confront industry managers and engineers daily. For further details on the conference,contact Environmental Science & Engineering Magazine, Tel:(416)727-4666, Fax:(416)841-7271. CETECH is co-sponsored by Ontario Pollution Control Equipment Association Participating sponsor: Air & Waste Management Association (Ontario Chapter)
Reed Exhibitions is a member of the Reed Exhibition Companies(REC), the world's largest exhibition organizer.
FOR MORE INFORMATION ON ATTENDING MANUFACTURING WEEK PLEASE CONTACT:
Reed Exhibition
Reed Exhibitions Inc.
Gompanies
800 Denison Street, Unit 7, Markham. Ont. L3R SM9
Teh (416) 479-3939
Fax:(416)479-S144
( o T7t m I t t f d
For more information, Circie reply card No. 136
I II
t X I
■ iI t
Aqua '92, Vancouver B.C.
AQUA '92 National Water Show and Conference List of Exhibitors ACTIVE CHEMICALS LTD.
DOUGLAS BROS. DIV. OF ROBERT MITCHELL
James C. Wilson, President Description; Oilsop will separate anytwo immersible fluids having different speci fic gravities. Booth #459
Paul Jones, Western Manager Description: Piping systems, metal fa
ALBERTA ECONOMIC
ENVIRONMENTAL SCIENCE &
brication Booth #445
LYNCH RESOURCES LTD.
Roy Campbell, President Description: Water leak detection, pipe line and cable locating utility installa tions, sales & service crews Booth #345
DEVELOPMENT AND TRADE
ENGINEERING
MANCORP INDUSTRIAL SALES LTD.
Behrooz Sadre-Hashemi, Director —
Steve Davey, Sales Director Description: Publication Booth #579
F.G. Sheffer, President Description: Water treatment recyciing system, high pressure washers
Trade Show Promotion
Booth #405/406/408
GUNDLE LINING SYSTEMS INC.
APPLIED MICROSYSTEMS
Steve McBeath, Marketing Manager Description: Manufacture instrumenta tion for water monitoring Booth #242 AZCO INDUSTRIES LTD. Vladimir Stuchlik, President Description: Ozonation equipment for water purification Booth #231
Tanya Woodlye, Marketing Assistant Description: Pond Liners Booth #413 HONEYWELL LIMITED
Carlo Caponio, Marketing Com munications Specialist Description: Water quality control products Booth #412A
Booth #346/347 NALCO CANADA INC.
Priya Lalico, Product Specialist Description: Video and posters on water reuse/recovery Booth #240 NORECOL ENVIRONMENTAL CON SULTANTS LTD.
BOA INDUSTRIAL CONTROLS LIMITED
Frank Van der Have, Environmental
Niko R. Zorkin, Ph.D., President Description: Picture displays
Sales
brochures Booth #569
W.T. Crane, President Description: Package water & waste water treatment plants Booth #456
Description: Multi parameter water quality monitoring instrumentation by Hydro Lab Booth #307
BARTOSCH TIDECO INDUSTRIES
IDEAL DISTRIBUTORS LTD.
William Payne, General Manager Description: Piping systems, metal
Brian Carrell, President
HOSKIN SCIENTIFIC LIMITED
fabrication Booth #445
Description: Water filtration ozone ge nerators, controls for monitoring ozone
BLUE WHITE INDUSTRIES
chlorine & pH controls Booth #304
W. Heath Race, National Sales Description: Chemical injection pumps, flowmeters Booth #306
THE BOSS/WATER MARKETING CORPORATION
Neal Y. Beaumont, President Description: Bottled drinking from BC Booth #463 BRINECELL
Tim Themy-Kotronakis, President Description: Separating H2O and NaCI chlorozone generators Booth #578
y2"-24" diameter used for water & gas lines, slurry & conduit lines, etc.
J & L INDUSTRIAL TANKS LTD.
John Greig, Manager Description: Glass fused to steel tanks, poly tanks, reflectix insulation, Norgard fire retardant Booth #577
treatment Booth #349
John Castelli, Manager of Communica tions
Description: Activated carbon products, systems and services Booth #241 COLUMBIA GEOSYSTEMS LTD.
Neil McLeod, President Description: Manufacturer and installer
Greg Jackson, Marketing Manager Description: gear motors,gear reducers, mechanical and electronic adjustable speed drives, brake motors,torque mon itoring systems Booth #419
Don C. Ingram, President Description: Pipeline rehabilitation for sewer & waterlines Booth #318 & 319 SCHONSTEDT INSTRUMENT
KISEKI WASTEWATER INC.
COMPANY
Bill Elligson, President Description: Manufacture, sell and ser vice micro organism augmentation
O.K. Davis, Manager Locator Products Description: Magnetic & cable locators designed for detecting buried iron and steel objects and tracing underground cables and pipes Booth #421
Booth #230
LIMNOTECK RESEARCH AND DEVELOPMENT INC.
SIERRA-MISCO
of geomembrane liner systems for water and waste containment pond liners, landfill liners — floating reservoir
Chris Perrin, President, Senior Aquatic Ecologist Description: Water quality and fisheries management consulting and research
covers Booth #457
services Booth #457
62
S.E.W. EURODRIVE CO. OF CANADA
SAMUEL PIPE LINERS INC.
JACUZZI CANADA
CORPORATION
Booth #423-B
LTD.
Serges Ouimet, Director, Sales and Dawn VanZant, Corporation Relations/ Marketing Business Development Description: Pumps and water systems Description: Ozone generator, water Booth #563 CARBON
POLYTUBES(WEST)INC. Brandon McCaffery, Sales Manager Description: Polyethylene pipe tubing
INTERNATIONAL PLASTICS LTD.
CALDERA RESOURCES LTD.
CALGON
POINT FOUR SYSTEMS INC.
Tjarda Barratt, Vice President Description: Oxygenators, water quality monitoring systems, aerators, engineer ing services Booth #550
Steve Little, Sales Manager Description: Joint restraint devices, Rainbird sprinklers, various plastic pip ing systems, PVC valves, water work accessories Booth #545B
water
and
James Sabran, Vice President, Marketing Description: Manufacture remote mon itoring for water & waste water man agement Booth #458
Environmental Science & Engineering. July 1992
Aqua '92, Vancouver B.C.
Tentative Program — September 9-11,1992 OPENING PLENARY Confirmed: John Cashore, Minister of Environment, Lands and Parks, Vic
toria. Invited: Kim Campbell, Minister of Justice and Attorney General of Ca nada; John A. Eraser, Speaker of the House of Commons, Canada
nois; Dr. Eerdinand Hager. Sonofloc.
Coodinator,B.C. Federation of Agricul
Vienna, Austria.
ture. Victoria. B.C.
SESSION 4: WATER CONSERVA TION CASE STUDIES SESSION 5: TREATMENT AND RE USE OF MUNICIPAL WASTEWATER Consultants Inc., Vancouver
AND POLICIES Confirmed: Bill Lightowlers, Canadian Environmental Industry Association, White Rock, B.C.; Bill Andrews, West Coast Environmental Law Association
Vancouver. Invited: Richard Taylor.
Union of B.C. Municipalities. Rich
(Note; The instmctors are the co authors of the Municipal Water Pric ing Guidelines)
QUES AND TECHNOLOGIES
SESSION 10: TRENCHLESS TECH
Confirmed: Michael Payne, Payne En gineering Geology, Sysney, B.C.; Bar ney Hiney, H-Two-O Environmental Service. Victoria; Kathy Wong. Advan
NOLOGY WORKSHOP
California; John Bell, Bell and Reading
SESSION 2: CLEAN AND SAFE DRINKING WATER
mental Canada,North Vancouver,B.C.; Donald Tate, Environment Canada.Ot tawa. Ontario
SESSION 6: INNOVATIVE TECHNI
ced Polymer Systems. Redwood City.
mond. B.C.
WORKSHOP Confirmed: Roger McNeill. Environ
Confirmed: Troy D. Vassos, Novatec
SESSION 1: NEW REGULATIONS
SESSION 9: WATER RATE SEHING
Engineering Ltd., Vancouver. Invited: Lome Mastin, Inonization Technol
ogy Corporation, Langley, B.C.
Confirmed: Michael Alldritt, Canadian Constmction Association. National Re search Council Canada. Vancouver;
Phil Coller, Iseld Inc.. San Diego, Cali fornia; Mike Smith, Trench Replace ment Systems, Inc., Calgary, Alberta; Jeffrey Addis, City of Vancouver. Vancouver
Confirmed: John Bell. Bell and Reading
Engineering, Vancouver; Dr. John Blatherwick. City of Vancouver; Dr. V.E. Mudie, Stanchem, Inc.. Etobicoke. On tario; Dr. Peter Huck, U of Alberta. Edmonton. Invited: Jack Bryck, Dayton
and Knight Ltd.,West Vancouver; Doug Neden. GVRD. Burnaby.
SESSION 7: INDUSTRIAL PER SPECTIVES ON WATER REGULA TION
SESSION 11: MANAGING WATER IN SMALL AND MEDIUM INDUSTRIES Confirmed: Cristina Jacob.GVRD.Bur
naby; David Van Seters. Peat, Marwick,
SESSION 8: GROUNDWATER MA NAGEMENT AND PROTECTION
Stevenson and Kellogg, Vancouver, Canada.Invited: Lucy Keating. Partner, Commexus Inc., Waterloo. Ontario
SESSION 3: WATER TREATMENT IN MAJOR INDUSTRIES Confirmed: W.H. Goodman, Nalco
Chemical Company, Naperville. Illi
Confirmed: Richard F. McNichol, Pre
sident,CPI Group ofCompanies,Langley. B.C.; Robert Palmquist. Senior Geologist. Applied Geotechnology.Inc. Bellevue; Margaret Crowley, Policy
SESSION 12: PUBLIC INFORMA TION AND CONSENSUS BUILDING Confirmed: Lucy Keating. Commexus Inc.. Waterloo. Ontario
Exhibitors List SMARTTURNER LIMITED
WATERGROUP INDUSTRIAL
Glen Monaghan, Regional Manager Description: Munioipai and industriai
Bryan Laird, National Sales Manager Description; Commercial/industrial
pumps and mixers
water filters, water softeners, deionizers, delkalizers, reverse osmosis systems,
Booth #344
deaerators Booth #323
SESSION 13: CANADIAN MARKET OPPORTUNITIES FOR THE 90s Invited: Tony Dorey, Chairman, Eraser Basin Management Board. Eraser Ba sin Management Program. Vancouver. B.C.
TERMINAL CITY IRON WORKS LTD.
Gordon Eden, Sales Manager
WATTS REGULATOR OF CANADA
Description; Manufacturer of water
Flyman Posner, Manager Description; Valves and regulators
fittings Booth #320
Booth #303 TYLER PIPE
Joel Blair, Utilities Sales Manager Booth #308
UV — WATERGUARD SYSTEMS D.F. Sommervilie, President
Description; Uitravioiet sterilization systems Booth #412 A right
WESTCOAST HYDRANT SERVICES LTD.
Bob Sheilds, President/General Manager
Description; Water main cleaning, fire hydrant & valve services, watts BFP's & ACV's Booth #570
SESSION 14: TRANSFERRING AND MARKETING TECHNOLOGY Confirmed: Aldyen Donnelly. SPARK. Burnaby, B.C.; Alan Cornford, Simon Eraser Univeristy, Burnaby, B.C.
Registration and exhibition informa tion contact: AQUA '92, P.O. Box
86278, North Vancouver, B.C. V7L 4S8. Phone 604-985-1143, Fax 604985-1192.
Environmental Science & Engineering. July 1992
63
FINALLY A TANK THAT'S GOOD TO THE LAST DROP Sloped to centre drain
Most economical way to store bulk products
Sturdy steel support frame Capacities from 100 to 6500 Imp. gallons
Open top and closed top units
Easily cleaned and virtually maintenance free
Better chemical corrosion resistance than F.R.R â&#x20AC;&#x201D;
stainless steel or mild steel Custom accessories to meet
your specifications
j4w -Arnnann OF CANADA LTD. 794 McKay Road, Pickering, Ontario L1W 2Y4 Tel:(416)683-8222 Fax:(416)683-2969 Toronto line:(416)798-7686
Leaders in engineering and technology in container systems For more information, Circie repiy card No. 137
Product Review Sampler survives submersion for 7-1/2 years! While conducting a monitoring project in Southern California in 1984,this Isco
Sampler was swept down a major trunk line. After an extensive search revealed
no sign of the sampler, it was pre sumed destroyed.
sampler still attached.The missing sam pler was retrieved intact! After its rescue,the sampler was close ly inspected for damage. The controller showed no signs of leakage! And, other than a radical change in color and a dead battery from being submerged in raw sewage for almost eight years, the Isco sampler seemed unscathed.The bat tery was replaced and the sampler was found to be completely functional.
meter probe measures temperature, pH, specific conductance, conductivity, re sistivity, TDS, redox, salinity, D.O., % saturation, and depth to 300 feet. It can spot check, log with a watertight display unit, connect to a laptop PC, or other RS-232 or SDI-12 device. Mea surement methods are U.S. EPA-
approved. Hydrolab For more information, Circle reply card No. 151
ISCO
For more information, Circle repiy card No. 150
Two Inch groundwater quality monitor
In January 1992, a sampling crew, conducting routine cleaning and main tenance on a siphon tube located down stream from the original sampling site, snagged a suspension harness with a
Making DSP more affordable for scientists
and engineers National Instruments announced that it
will include its NI-DSP high-level, ready-to go digital signal process (DSP) software library at no charge with its DSP plug-in boards for PC AT and
Hydrolab has introduced a new mon itor for 2 in. wells. Just one 1.7 in. dia-
Laboratories Environmental and Industrial Analytical Services Trace Metals, Organic and Inorganic Analyses Waters, Soil, Sediments, Vegetation, Rocks and Minerals, Air Particulates, MISA, Reg. 309, Decommissioning Guidelines, Drinking Water Guidelines, Sewer Use By-laws, Effluents, Industrial Waste, QA/QC, Special Projects and Methods Development. We have a team of highly professional and experienced staff \«ho would meet your specific requirements and standards.
Alpha Laboratories Inc. 285 Lesmill Road, Don Mills, Ontario M3B 2V1
Tel:(416)449-2166 / Fax:(416)449-0816 "Serving Industry & Gov't. Over 25 Years"
BARRINGER LABORATORIES
L^r^ ||r 1
• environmental and discharge analyses • Reg. 309 and MISA compliance • Phytotoxicology and Water Quality
• fire assay and field sampling services
Main Lab: 5735 McAdam Rd.,
Mississauga, Ontario, L4Z 1N9, Tel: (416) 890-8566, Fax:(416) 890-8575
Other Labs: Calgary, AB Denver, GO Kirkland Lake, ON
Timmins, ON Red Lake, ON Thunder Bay, ON Montreal, PQ
Macintosh NuBus computers. Scientists and engineers can use NI-
DSP to develop real-time digital signal and data processing applications on the company's AT-DSP2200, NB-DSP2305, NB-DSP2301,
and
NB-DSP2300
boards. NI-DSP includes a high-level software library of 32-bit, single-preci sion, floating-point analysis functions for Fourier and spectral analysis, digital filtering, waveform generation, statisti cal analysis, vector and matrix algebra, and numerical analysis. National Instruments
For more information.
Circle reply card No. 152
Excellence in ■nni —1, ihhh LsbowtonBs HI1
LintitBd
Environmental Analysis
SanBB Consulting
for Over 25 Years
■■■■■ Chemists
14 Abacus Road Phone (416) 458-4505 Brampton, Ontario Fax (416) 458-7303
Environmental
Canada L6T 5B7
New LabWIndows for DOS Version 2.2 National Instruments has announced a new version of its LabWindows soft
ware development system for DOSbased data acquisition and instrument control applications. LabWindows Version 2.2
features
many new enhancements to the analy-
Environmental Science & Engineering, July 1992
65
Laboratories
Product Review sis libraries for real-time digital signal processing (DSP) using the AT-DSP2200 board, to the User Interface Lib
rary(UIL)for interactive graphics, and to the data acquisition library for sup port of the SCXI signal conditioning system. National Instruments For more information, Circle reply card No. 153
Pumps for abrasive slurries and liquids
CanTest Ltd Professional
cmTzSf
Analytical Services Suite 200 1523 West 3rd Ave
Environmental Analysis
Vancouver, B.C.
Hazardous Waste Characterization
V6J 1J8
Occupational Health & Safety
Tel: 604 734 7276
Fax; 604 731 2386
OVER 20 YEARS OF ANALYTICAL EXCELLENCE
Comprehensive
hNVIRONMENTAL
• Complete MISA Parameters
• Regulation 309 Compliance • Dioxons/Furans
• Air Analysis • Soil Decommissioning
Laboratories
• Ontario Drinking Water Criteria
CANVIR® Bathurst IJrive, Wacerloo, Oncario N'2V 2C5 Tel: (519) 747-2575
Fax (519) 747-380q
Chemex Labs Environmental Services ►Analysis of trace metals/lnorganics/organlcs/radlolsotopes ►Water & waste analyses ►Contaminated site and hazardous waste monitoring ►Certified by CAEAL/Registered with BG MOE ►On-site composite sampling services Vancouver, BC (604) 984-0221 MIsslssauga, ON (416) 624-2806 Rouyn. PQ (819) 797-1922
Designed to handle the highly abrasive media found in mines, mineral process
ing plants, quarries, sand and gravel pits, the 5500 and 5600 series pumps from Flygt cover a wide range of flow
and can be submerged to a depth of 20m.
These pumps are equipped with new ly developed slurry seals and are de
signed for ease of access to internal components for minimum disruption
Clayton ENVIRONMENTAL CONSULTANTS
A Marsh & McLennan Company
949 McDougall Avenue Windsor, Ontario N9A
1L9
ENViFtONMENTAL AND INDUSTRIAL HYGIENE ANALYTICAL LABORATORY SERVICES
Regulation 309 • Ivtetals • Inorganics • Organlcs Volatile Organlcs • BTEX • Asbestos • PCBs Gas Bag Analysis • Odour Panels • Isocyanates
Inquiries about additional analytical services are encouraged
(519)255-9797
FAX (519)255-9304
and maintenance. The 5500 series is available in six alternative power capa^
cities, ranging from 2 to 44KW, with
three different pump housing options. The 5600 series has drive units ranging from 5.9 to 90KW. ITT Flygt For more information, Circle reply card No. 154
Conical bottom
storage tanks
OIILL©ini
M. M. DILLON LIMITED
Environmental Laboratories
YELLOWKNIFE
OTTAWA LONDON CAMBRIDGE
Certified by Canadian Association of Environmental & Analytical Laboratories MISSISSAUGA
(416)568-1414
FAX
(416)568-1339
TORONTO WINDSOR WINNIPEG
GCG DILLON CONSULTING LIMITED EDMONTON
•
RED DEER
PORTER DILLON LIMITED HALIFAX
•
SYDNEY
Aco-Assmann has introduced a new
line-up of conical bottom storage tanks with capacities from 100-3500 gallons. Conical bottom tanks provide the most economical way to store bulk li quids. The full drain design allows utili zation of every last drop of liquid. Manufactured from either linear or
crosslink polyethylene, the uniform wall construction means excellent im
pact and corrosion resistance at a frac tion of the cost of stainless steel. 66
Setting the standard for *
ENVIRONMENT PROTECTION LABORATORIES INC.
service
* quality * turnaround time
6850 Goreway Drive, Toronto, L4V IPl, Tel; (416) 673-3255, FAX: (416) 673-7399 Environmenlal Science & Engineering. July 1992
Laboratories
Product Review
Analytical Laboratory A Division of Gore&Stonie Limited
• Environmental Analytical Services •Specific Analysis Certified by CABAL • MISA, Sewer Use Compliance Testing
All Ago conical tanks can be easily cleaned, and are virtually maintenance free. The complete discharge feature al lows for quick cleaning and minimizes the chance of contamination when
changing to a different product.
• Hazardous Waste Characterization
Aco-Assmann
•Site Decommissioning Guideline Testing
For more information, Circle reply card No. 155
55 Research Rd.,Toronto. Ont. M4G 2G8,Tel;(416)696-0390, Fax:467-5227 1-800-563-9275
Microprocessor-based, Comprehensive Environmental Anaiyticai Services
In-line turbldlmeter
Air Quality » Water Quality » Hazardous Waste
systems
• Complete MISA Parameters
• Emission Testing
• Reg. 309 Compliance • Polychlorlnated Dibenzodioxins/Furans
• Ontario Drinking Water Criteria • Odorous Compounds • Rush Analysis Available
• Ambient Air Monitoring
Mann Testing Laboratories Ltd. Professional Analytical Services Since 1972 5550 McAdam Road, MIsslssauga, Ontario L4Z 1P1 Phone: (416) 890-2555 Fax: (416) 890-0370
Designed to meet the stringent require ments ofclean water applications,these ■new in-line turbidimeter systems mea sure ultra-low turbidity levels, as well as levels to 60 NTU's. They are suitable for
critical monitoring and controlling of final product clarity of aggressive or flammable chemicals where side stream
XRAL ENVIRONMENTAL
instruments cannot withstand operat ing parameters.
A DIVISION OF SGS SUPERVISION SERVICES INC. Since 1878
ANALYTICAL SERVICES
MISA • Process/Wastewater • Soil • Solid Waste
Elemental Scans • Characterizations • RGB's • Sampling "16 SGS Locations Across Canada"
1903 Leslie St. Don Mills, Ontario MSB 2M3
Tel: (416) 445-5809 Fax: (416) 445-4152
ZENON ENVIRONMENTAL LABORATORIES •QUALITY ASSURED-DELIVERY GUARANTEED" PROVIDING COMPLETE ENVIRONMENTAL ANALYSIS ACROSS CANADA
Burlington, Ontario (416)332-8788 Vancouver, B.C.(604)444-4808 Montreal, Quebec(514)493-4733
A key feature of these new tur bidimeter systems is the LED pulsed light sources and photodetectors. The light sources are alternately pulsed, with the photodetectors alternately reading an active signal and a reference signal. A ratiometric algorithm eliminates error factors due to electronic drift light
Consultants
source aging, electronic gain, and photodetector scale factors.
Acres International Limited Consulting Engineers Environmental Assessment•Waste Management•Industrial Hygiene Environmental Audits• Air Quality•Environmental Modeling Wildlife Management• Land Use Planning
Great Lakes Instruments, Inc. For more information, Circie reply card No. 156
Schlumberger introduces insertion-type vortex shedding fiowmeter
480 University Avenue,Toronto, Canada MSG 1V2• Tel. 416-595-2000•Fax 416-595-2127 St. John's • Sydney • Halifax • Niagara Falls • Burlington • Winnipeg • Calgary • Vancouver
Ainley and
A
Associates Limited CONSULTING ENGINEERS & PLANNERS
INTEX 3500'" insertion-type vortex
Water Supply S Sewage Disposal • Roads & Bridges • Flood Conitoi Solid Waste Disposal • Municipal Drams • Land Use Planning
COLLINGWOOD
BARRIE
BELLEVILLE
OTTAWA
280 Pretty River Parkway
48 High Street
205 Dundas Street
Box 917, R.R.5
(705) 445-3451 Fax (705) 445-0968
(705) 726-3371 Fax (705) 726-4391
(613) 966-4243 Fax (613) 966-1168
Fax (613) 822-1573
Environmental Science & Engineering, July 1992
(613) 822-1052
shedding flowmeters feature advanced, dual piezoelectric sensor technology. Accuracy is +1% of reading with 0.25% repeatability. 67
Product Review
Consultants
INTEX 3500 is recommended for in
Environmental Auditing and Management Planning Waste Management solutions
stallation in line sizes from 2" to 36"(51 to 915 mm). The meter has a high turn down, low-flow sensitivity, to 1.3 ft/sec
(0.4 m/sec), and a wide temperature range of-400 to 650°F (-240 to 343°C). They can be used to measure the flow
of gases,liquids and saturated or super heated steam.Its sensors are immune to
to the 4 Rs
ENVIRONMENTAL CONSULTING LTD.
Wastewater Treatment
design engineering Air, soil, waste and water analytics, studies and troubleshooting
Environmental and occupational health and safety specialists Serving industry in Canada
fluid noise, maintaining a high level 225Sheppard Ave. W., Willowdale, Ontario M2N 1N2
of sensitivity. Schlumberger
(416) 226-0148
For more information, Circie repiy card No. 157
R.V. Anderson Associates Limited 1-1/2" turbo-meter consulting engineers and architect
features built-in strainer
Water Resources
Environmental Planning Land Development Transportation Tunnels and Shafts Architecture Municipal Services
TORONTO (416)497-8600 OTTAWA (613)226-1844
WELLAND (416) 735-3659 OSHAWA (416)434-2544 SUDBURY (705)671-9903(Dennis Consultants)
Water Pollution Control
Water Supply
AquaticSciences inc.
Environmental Scientists Commercial Divers
UNDERWATER AND ENVIRONMENTAL SERVICES
Sensus' W-120-S Turbo-Meter has an
operating range of 4 to 120 gallons per minute (0.9 to 36 mVh) and complies
• spil l site investigations and cleanups
with ANSI/AWWA Standard (most recent revision).
• underwater video inspections
• impact assessments
C701
A v-shaped strainer is built into the bronze maincase to prevent debris from entering the measuring chamber and damaging the meter's rotor. The V/2" W120-S Turbo-Meter includes a down
stream test plug to make on-site mea surement accuracy testing more access ible and convenient. The Model W-120-S Turbo-Meter fea
• water quality monitoring
P.O. Box2205, Station B, St. Catharines, Ontario L2M 6P6
ENVIRONMENTAL ENGINEERING
(416)641-0941
INTERNATIONAL BRITISH COLUMBIA
SASKATCHEWAN
SERVICES
ALBERTA
ONTARIO
tures Sensus' patented Right Angle Magnetic Drive which eliminates con ventional worm or miter gears. A num ber of standard reading, and Electronic Communication Registers (ECRs) are
ASSOCIATED
ENGINEERING
available. Sensus
For more information, Circle repiy card No. 158
C.C. TATHAM & ASSOCIATES LTD. Consulting Engineers
New pH monitoring system
Specialists In a comprehensive range of Environmental and Municipal Engineering 115 Hurontario Street, Suite 201,
Collingwood, Ontario L9Y 2L9
Tel.(705)444-2565 Fax(705)444-2327
CHMHILL
Consulting Engineers
CH2MHILL ENGINEERING
Waterloo • Toronto • Calgary • Edmonton • Vanqpuver • Lethbridge Wastewater Collection & Treatment
EC1000 Process pH Monitoring System is designed for monitoring and controll ing pH in many industrial and munici pal applications. The electrode assembly features a 68
Hazardous & Solid Waste Management Water Resources & Environmental Planning
• Water Supply Strategies • Analytical Testing • Field Sampling & Flow Measurement
WINNER OF THE AWARD OF EXCELLENCE - WASTEWATER
CANADIAN 1990 NATIONAL ENVIRONMENTAL AWARDS PROGRAM
FOR THE STUDY & DESIGN OF A MUNICIPAL SLUDGE MANAGEMENT SYSTEM
Environmental Science & Engineering, July 1992
Product Review
Consultants
li Clayton
SPECIAUSTS IN ENVIRONMENTAL
ENGINEERING,INDUSTRIAL HYGIENE, AND LABORATORYSERVICES
ENVIRONMENTAL CONSULTANTS A Marsh & McLennan Company
• Underground Storage Tank Management, investigations and Remediations • Environmental
WINDSOR [519)255-9797
II
TORONTO C41B}498-74'14
Assessments
I
Audits
• Ambient Air Monitoring and Source Testing • Analytical Laboratory Services
Dames & Moore. Canada
■==!i^
the environmental professionals
Consultants in Hydrology, Waste Management, Environmental Engineering and Hydrogeology 7560 Airport Rd., Mississauga, Ontario
L4T 2H5
Tel: (416) 671-9921 Fax: (416) 672-7784
Comprehensive consulting services in engineering and
unique reference electrode design that replaces conventional porous junctions with a free-flowing, non-clogging liquid/ liquid interface. Because there is no porous material to clog, free electrolyte flow is assured and the electrode lasts
longer
because it
cannot
become
fouled.
As the system is microprocessorbased, reliable sample monitoring cov ers the full 0-14 pH range. In addition to pH measurement, the system also measures millivolt (mV) po tentials and temperature. Hach Company For more information, Circie reply card No. 159
Hazardous Waste Site Monitor OVA Organic Vapour Analyzer is a light, portable instrument ideally suited to performing a variety of analysis re quirements, both qualitative and quan titative, for waste site management.
, Golder
Assocmtes
Offices fhoughouf North America, Europe andAustraiia.
environmental sciences
internationally
MISSISSAUGA
Tel: (416)567-4444 Fax: (416)567-6561 VANCOUVER
Tel: (604) 879-9266 Fox: (604) 879-5014
ENGIfsJbfcMS PLAMSJB=S AFOHTECJTS
» ENVIRONMENTAL ASSESSMENT AUOITS & PLANNING » MUNICIPAL AND INDUSTRIAL WASTEWATER TREATMENT • PLANT DECOMMISSIONING • SITE REMEDIATION • SOLID AND HAZARDOUS WASTE MANAGEMENT
» WATER SUPPLY. TREATMENT AND DISTRIBUTION
The dual mode OVA 128GC can de
termine THC or the extent of specific volatile organic contamination in air, water or soil; the level of respiratory pro tection required and can confirm the identity and concentration of chemicals
OIILL©n Consulting Engineers • Planrters EnvironmentaJ Scientists
present. M. M. DILLON LIMITED
OTTAWA LONDON CAMBRIDGE
TORONTO WINDSOR WINNIPEG
GOG DILLON CONSULTING LIMITED EDMONTON
PORTER DILLON LIMITED HALIFAX
SYDNEY
RED DEER
YELLOWKNIFE
DILLON ENVIRONMENTAL LABORATORIES MISSISSAUGA
Other versions are available for fugi tive emission monitoring and other ap plications. All ova's are certified in trinsically safe for use in Class 1, Divi sion 1, Groups A,B, C and D areas. Nortech Control Equipment Inc. For more information,
Circle reply card No. 160
Professional
TORONTO, ONT
(416) 477-8400
Services in
VANCOUVER, B.C.
(604) 299-4144
Environmental
Management
Gartner Lee
Environmental Science & Engineering, July 1992
NIAGARA FALLS, NY (716) 285-5449
Stack Gas
Monitoring System In response to demands for reliable, simple to use stack monitors, Nortech introduced the RF Series of instru
ments. Available as portable or station ary monitors, the RF Series uses an unique gas filter corelation technique to 69
Consultants
Product Review
Environmental/Occupational Health and Safety
PROFESSIONAL CAPABILITIES: • Environmental Engineering 'Training programs •Legal compliance/clesignated substances > Ventilation assessment/design > Air emission control • Air monitoring 'Environmental audits •Indoor air quality • WHMIS • Noise monitoring and control
•Workplace and safety audits •Asbestos
GOODFELLOW CONSULTANTS INC.
Telex: 06-218242
2000 Argentia Road, Plaza III. Suite 301 Mississauga, Ontario L5N 1V9 Canada•(416)858-4424
Fax:(416)858-4426
Bore S.Sborrie Limibed Consulting Engineers WASTEWATER • WATER •SOLID & HAZARDOUS WASTES•DRAINAGE WATER RESOURCES•ENERGY RECOVERY •ENVIRONMENTAL PLANNING
offer users extremely stable and accur
LABORATORY SERVICES—ANALYTICAL & PROCESS R&D
ate readings. Instruments are not affec ted by vibration, absence of oxygen or the presence ofothergases in the sample
255 Consumers Road, North York, Ontario M2J 5B6
Telephone (416) 499-9000 Fax (416) 499^687 Ottawa •Thorold • Barrie•Cambridge • Mississauga • Kingston • London
stream.
Applications include monitoring car bon dioxide (CO2), oxides of nitrogen
(NO/NOx) sulphur dioxide (SO2) and others.
Nortech Control Equipment Inc. For more information,
Circle reply card No. 161
Environmental Consultants
Ai INTERK
aAAA^ Environmental Division
• Hydrogeologic Investigations • Site Remediation
• Hazardous Waste Management
Unicase design solves three problems
OTTAWA
• Water Supply and Treatment
TORONTO
TEL: (613) 226-5442 FAX: (613) 226-5529
TEL: (416) 635-5882 FAX: (416) 635-5353
• Environmental Audits
• Groundwater Modeling
A Division of Inters Information Technologies (Canada) Ltd.
a
Consultants for water and pollution control projects
Knox Martin Kretch Limited Consulting Engineers, Planners, Landscape Architects
Nord integral gearmotor construction assures application matched perfor mance. With the Nord gearmotor de sign,the possibility of adding an under sized or oversized motor is virtually eliminated. These gear drives are also factory filled with oil to prevent damag ing dry start-ups. For added protection, Nord introduced the Quadrilip sealing system that provides twice the leakage efficiency offered by the double lip seals.
a
220 Advance Boulevard, Brampton, Ontario. L6T 4J5 (416) 459-4780 Fax. (416) 459-7869 Kitchener (51 9) 743-61 1 1 Cobalt (705) 679-5979
1^ PONDAINE,CDWIE,BUR4nO &>lSBaaATES UMITED Consulting Engineers
Windsor, Ontario
WATER TREATMENT AND DISTRIBUTION • ENVIRONMENTAL ASSESSMENTS WASTEWATER COLLECTION AND TREATMENT • STORMWATER DRAINAGE LAND DEVELOPMENT • ROADSANDBRIDGES • STRUCTURAL INVESTIGATIONS INFRASTRUCTURE STUDIES • MECHANICALAND ELECTRICALSYSTEMS 3260 DEVON DRIVE, WINDSOR,ONTARIO, N8X4L4
(519) 966-2250
BRANCH OFFICE-WOODSTOCK
FAX:(519) 966-5523
(519) 539-2015
Nord helical-worm gearmotors and speed reducers are available to meet a wide variety of application needs. An input cover for belt, chain or direct coupled input. Scoop motor mounting, platform motor mounting C-face and lEC input flange motor mounting. Customers can choose from two styles
MacVlro Consultants Inc.
of adjustable speed drives. The Nordisc traction drive offers a 7:1 adjustable speed range for applications up to 5 HP. Nord also offers the Titan belt type drive 70
7270 Woodbine Avenue, Third Floor • Morkham, Ontorlo. L3R 4B9 • Telephone:(416)475-7270 • TeleFAX;(416)475'5994
Consulting Engineers, Planners and Scientists, Specializing In the Environment Environmental Science d Engineering. July 1992
Consultants
Product Review
•Hydrogeology •Waste management •Engineering geology
MALROZ ENVIRONMENTAL ENGINEERING
•Environmental audits MALROZ Engineering inc. 168 Montreal St., Kingston, Ont. K7K 3G4
•Site decommissioning
Tel:(613)548-3446 Fax:(613)548-7975
& rehabilitation
Marshall Mackiin Monaghan Limited
with up to a 6:1 speed range capable of handling speed applications up to 125 HP.
The wormwheels are made from high strength centrifugally cast bronze. All worms are carburized and precision ground. Bearings are rated for a mini mum 5000 hours B-10 life per AGMA standard 2001. Nord
For more information,
Circle reply card No. 162
Comminutors for solids reduction in wastewater
Consulting Engineers Surveyors Planners
Specialists in Environmental Planning and Engineering, Hydrogeology, Waste Management and Water Resources
I
80 Commerce Valley Drive East Thornhill, Ontario L3T 7N4 (416)882-1100 Fax:(416) 882-0055
TORONTO, EDMONTON
Burlington, Mississauga, Whitby
Proctor & Redfern Limited Consulting Engineers Architects Planners Environmental Scientists Water Supply, Treatment, and Distribution
Pollution Control Inc., a manufacturer
of physical, chemical, and biological wastewater treatment equipment lo cated in Florence, Kentucky, offers a complete family ofcomminutors for the
Wastewater Collection and Treatment
reduction of solids in wastewater flows.
Solid and Hazardous Waste Management
The PCI comminutors reduce the solids
Hamilton
Kenora
Kingston
Kitchener
St. Catharines Sault Sic. Marie
London
Sudbury
North Bay
Thunder Bay
Ottawa
Windsor
45 Green Belt Drive. Don Mills, Ontario M3C 3K3 Fax: (416) 445-5276
Tel: (416) 445-3600
in order to accelerate the biological phase of the process and assure the thorough treatment. The comminutors offered by Pollu tion Control Inc. feature heavy duty, corrosion resistant, cast aluminum con
struction. The low overall weight of the units assures ease of installation and 8IMCOE ENOINEERIIMO GROUP LIMITED
Consulting Engineers & Architects WATER SUPPLY • POLLUTION
CONTROL
DRAINAGE • SCADA
ARCHITECTURAL SERVICES
345 Kingston Rood, Pickering, Ontario L1V 1A1
Tel: (416) 286-2285
Fox: (416) 286-1361 Ottawa
London
Cambridge Regina
Stanley
Saskatoon
Calgary Edmonton
Environmental
Vancouver
Engineers, Scientists, Project Managers
Enquiries:
Water, Air, Soils
(519) 622-3060
handling. The drives are weatherproof. Class No. 3 reduction type worm gear ing. The gearbox is protected from heavy shock loads by a torque clutch in the driveline minimizing the possibility of drive shaft damage in the event of blockage. The comminutor can be sup plied with additional protection if the optional control panel is supplied. The control panel contains automatic rever sing controls. Once the comminutor en counters a hard object obstructing rotation it will briefly reverse the motion of the cutting drum jarring the object loose. It will then resume rotation in the
normal direction. This optional feature minimizes the possibility of overload of the drive motor and structural damage to the unit. Pollution Control Inc.
TECHNITROL•ECO INC. Environmental Consultants — Laboratory Analysis
Industrial Expertise Since 1963 ENVIRONMENTAL AUDITS IMPACT STUDIES RISK ASSESSMENT WASTE MGMT.
SAMPLING & ANALYSIS
• SITE CHARACTERIZATION • DECOMMISSIONING
• INDUSTRIAL HYGIENE
• PLANT COMPLIANCE AUDITS
• STACK SAMPLING • TOXICITY TESTING
• UST REMOVAL • PERMITTING
Engineering. July 1992
Atomic Absorption Software
• AIR QUALITY
• MICROBIOLOGY
121 HYMUS BLVD., POINTE-CLAIRE, QUEBEC H9R 1E6 TEL.(514)697-3273 FAX:(514)697-2090 Environmental Science
For more information, Circle reply card No. 163
The DPIOOO software will collect and
analyze data from most models of atomic absorption instruments using either analog or RS232 data. Compa tible with graphite, flame, cold vapor 71
Consultants
Product Review and fiydride systems.
• Water Resources • Instrumentation and Controls •
Software plots raw data, does base line and drift corrections, displays stan dard curves and produces customized reports. Can be used for standard addi tion and CLP protocols. Automatically
• Supervisory Control and Data Acquisition
links to all LIMS and most other soft
THORBURN PENNY LTD. Consulting Engineers • Water Supply • Environmental Planning • Water Pollution Control
ware programs. Labtronics Inc. 400 Main Street East
Milton, Ontario
Tel:(416)875-2144 Fax;(416) 875-2145
For more information,
L9T 4X5
T,F: 1-800-263-4178
Circle reply card No. 166
Stationary MISA-grade Sampler
Complete Environmental Service
engineers architects
Water Supply ♦ Waste Water ♦ Needs Studies ♦
planners
Environmental Assessment ♦ Environmental Audits
sIms
♦ Solid Waste Management ♦ MISA TEL.(416)668 9363 WHITEY FAX.(416) 668 4045
hubicki
COBOURG ♦ TORONTO 4 KINGSTON 4 HUNTSVILLE 4 SIMCOE
totten
BRACEBRIDGE 4 OTTAWA 4 SAULT STE. MARIE 4 WATERLOO
UMA Engineering Ltd. Telephone:(416)238-0007 ENVIRONMENTAL CONSULTANTS & PROJECT MANAGERS
TO GOVERNMENT,INDUSTRY, PRIVATE SECTOR HAUFAX'TORONTO-OTTAWA'LONDON'SUDBURY'WINNIPEQ-REQINA'SASKATOON-LETHBRIDQECALGARY-EDMONTON-BURNABY-WHITEHORSE-YEUOWKNIFE AND THE U.SA
ISCO 3700 Series Stationary Water
ENVIRONMENTAL NOISE & VIBRATION
^ \
• Measurement, Prediction, Assessment, Expert Testimony • Design and Specification of Control Measures • Road, Rail & Air Traffic, Manufacturing Plants, Industrial Processes, Landfill Sites, Quarries, Presses, Blasting
Consulting Engineers 1720 Meyerside Drive, Mississauga, Ontario L5T 1A3
Samplers offer advanced features and reliability. Patented, non-contacting li quid presence detector achieves accu rate and repeatable sample volumes and will automatically compensate for
Tel:(416)670-4922, Fax:(416)670-1698 Halifax (902)455-3112 Waterloo (519)746-3415
changes in sample load. Easier to program than most VCRs. the two line,40 character display promts the user to the next step. A printer output and the ability to link the sampler to a
WILLMS & SHIER/BARRISTERS & SOLICITORS
computer eliminates guesswork during the sampling routine. Samplers are available in a variety of configurations and offer the user a choice of power sup
Environmental and Waste Management Approvals, Municipal Law, Land Use Planning and Development. Occupational Health and Safety, Environmental and Civil Litigation Richmond Street West
plies and other sampling accessories.
Toronto. Ontario
Nortech Control Equipment Inc. For more information, Circle reply card No. 171
MagMaster Flowmeter ABB Kent-Taylor has announced the
introduction of'MagMaster',a magnetic XCG Consultants Ltd.
flowmeter claimed to be so revolution Suite 904
519/741-5774 Fax 519/741-5627
50 Queen Street N
Kitchener, Ontario
N2H 6P4
Providing Senior Consulting Advice on Environmental Matters
Engineering
Richard J. Rush MASc, PEng
Stephen G. Nutt MEng,PEng
Consultants
Principal
Principal
Environmental
PUT OUR FORTY YEARS OF EXPERIENCE ON YOUR TEAM
72
ary it could define new standards. This DC magmeter combines the benefits of DC mags with the noise re jection capability of AC mags. Microp rocessor signal processing enables this meter to achieve an accuracy of+/-0.2% with a 1000:1 turndown ratio.
ABB Kent-Taylor For more information. Circle reply card No. 170
Environmental Science & Engineering, July 1992
Literature Review For information on advertising in this section call ES&E at(416) 727-4666 Concrete Pipe Seals
pH Recorder and
Tylox super-seals do not require messy time consuming lubricant ap plications.Seals are automatically in jected with siiicone,allowing mantles to roll over the compressional area of gaskets, ensuring water tight seais. The mantle sections' final resting area is between the annular space, reducing extensive sheer forces. r\/laterial conforms to, or exceeds, C.S.A. or A.S.T.M. specifications.
Controllers The fvlodel RCP75,is a pH Recorder and Controller with a strip chart re corder for a permanent record. One roll of chart paper will run approx imately 1 month at 1' per hour,fvlodel RCDp75 Is the same as the l^odel RCP75 with a Digital read-out. The fvlodel 1CP75 is a pH Indicator-Con troller If a permanent record is not required.
Hamilton Ken
Analytical Measurements of
Circle reply card No. 226
Canada Ltd.
Circle reply card No. 220
Need a pump? Contact the experts first
CANVIRO Analytical tfERS/aiU
Laboratories Ltd. Our quality program begins with Ini tial contact with our laboratory. From
sample container preparation through the reporting of your results, estab lished QA/QC procedures are stric tly followed. A dedicated QA/QC of
Vmmic
York Fluid Controls has handled
thousands of diaphragm pump ap plications for over 21 years. As spe cialists In this industry, we have an extensive background and service to all types of industries in Canada.
'h" & V
Engineered Plastic
Air
Diaphragm Pump #
EnjiiiMm FUiK Pi>n«i hr Canute
ficer oversees and reviews the entire
Available from 172" to 3" sizes and
SctnnU
process. Analysis is performed on state-of-the-art equipment using ap proved methodoiogles that meet ail requirements of reguiatory guide-
flow to 240 gpm these Versa fvlatic pumps move virtually any products that flow through a pipe including most chemicals, sludges, slurries,
iines.
solvents, etc.
CANVIRO Analytical
Versa fVlatic is stocked in Canada by
Laboratories Inc.
York Fluid Controls Limited.
Circle reply card No. 227
York Fluid Controls Ltd.
Circle reply card No. 221
Super Press Sludge SUPERPRESS: SLUDGE
DEWATERJNG USING BELT FILTERS
Sa/i/LU
SouCamSanwier
of belt filters suited to all kinds of
sludge(municipal and Industrial) de pending on Its final destination: land fill, compost. Incineration. Superpress sludge belt filters are safe, easy, reliable and economical to operate. Throughput, dryness and chemical consumption guarantees are provided. Degremont Circle reply card No. 225
tamlnated and undisturbed; can be collected In clear PVC tubes to allow
viewing of stratigraphy, without dis turbing the sample. Solinst Canada Ltd.
f
Circle reply card No. 222
Soiinst
n uupcmimt
Instrument Control and
Data Acquisition J IEEE-488 and 2 VXIbus Control, 1 Data Acquisition, and Analysis.
Soil Core Sampler For microbiological or geochemical analysis of soil and porewater. Sam pler collects continuous 5' by 2"core samples without a drilling rig or the use of drilling fluids. Samples retain up to 98% pore fluids; are uncon-
Belt Filters Degremont offers a complete range
Free 1992 catalogue of Instrumenta
tion products for PCs workstations, and more. Features IEEE-488.2 in terfaces and software, plug-in data
acquisition boards, VXibus con trollers, DSP hardware and software and signal conditioning accessories. Application software for complete acquisition, analysis, and presenta tion of data,including graphical Inter faces. Application tutorials and train ing classes also detailed. National Instruments
Circle reply card No. 223
Instrument Rentals tnvironmratol I
REMTfl
Select from over40 different environ
mental Instruments for daily, weekly or monthly rental. Dust, fvtist. Fibre Monitors• FiDs•GCs•PIDs• LEL,
Toxic & Oxygen Monitors Radiation Meters Water Quality Meters Decon Trailers. NOW AVAILABLE
insobutyiene and other cal gas & support accessories. HAZCO Canada, Inc. Circle reply card No. 224
Product Review Flexscourâ&#x201E;˘ stainless steel ming pool for over three hours and hired a scuba team to take photos of the unit functioning underwater in adverse con ditions. After the photo shoot, the sam pler was disassembled to check for leakage. Not a drop was found â&#x20AC;&#x201D; even the humidity indicating paper had not changed colour! In addition to the environmentally
underdralns
sealed controller, Isco 3700 Series Sam
plers feature exclusive, STORM'" pro gramming to allow both first flush samples and flow weighted samples to be collected in the same sampler. The patented pump revolution counting sys tem and innovative LD90'" non-contac
Environmentally sealed Isco samplers Some sampler manufacturers claim their products are sealed against submersion. To make a point,Isco submerged a stock 3700 Series portable sampler in a swim
Capacitance systems for effective pump protection A dry pump can be a costly event on positive displacement pumps, par ticularly the progressive cavity type. When dry, these pumps will not run for long without overheating, causing cos tly repairs and downtime.
ting liquid detector provide precise sample volume delivery in any liquid.
Sequential and composite sampling models are offered with a variety of bot tle configurations for use in a wide range of applications. Isco Circle reply card No. 175
ted into being the sensor such as a clean out port.This has proved to be a very low cost, reliable technique. ARJAY Circle reply card No. 176
Underdralns are at the heart of every granular media filter. If the underdrain is well designed, durable and efficient, the filter will provide many years ofcon tinuous service. If not, the underdrain,
and perhaps the entire filter may require replacement after only a few years use. Flexscour underdralns provide a dur able, corrosion-resistant system for col lecting filtered effluent and accurately metering uniform air/water backwash flows. Innovative design features elimi nate the two flow problems that have plagued other combined air/water cleaning systems:improper sizing ofva riable diameter orifices, and media dis
placement by surging or irregular flows. Separate ducts for air and water and improved orifice sizing are the keys to uniform flow distribution.
Want to upgrade your knowledge of environmental affairs-see page 57.
EIMCO Process Equipment Circle reply card No. 177
Portable waste water
sampler for hazardous environments
Capacitance detection circuits have proven to be an extremely reliable and low cost method of dry-pump protec tion. The probe is fabricated to form a capacitor with ground as one side and the pumped fluid being the medium dielectric.
The other side of the capacitor (re ferred to as the sensor) is connected to the control circuit. The physical con
figuration of the probe can suit the size and type of pump.The most common is to have the sensor plate and ground con nection imbedded in a PVC ring flange which mates to the inlet port of the pump. On some large pumps a part of the pump's construction can be conver74
Epic 1511 automatically extracts rep resentative samples ofliquids including crude sewage and some sludges for ana lysis.Powered by a separate intrinsically safe power pack, the 1511 can be pre programmed to control start times,sam pling interval (or flow impulse), run times, sample volume and number of samples per container. Operated in flow-proportional mode the 1511 can be initiated by an approved flow meter. Two interchangeable base modules cover sample container sizes up to 12L composite, or 24 individual containers. The sampler is operated by a plug-in programmer unit comprising an alpha numeric LCD display and four push button controls. Programming options include: choice of 8 European lan guages, security code access, diagnostic self-test routine, programmable sample routines and remote operation.
1
Cancoppas Circle reply card No. 178
Environmental Science & Engineering, July 1992
Schlumberger Provides Solutions Schlumberger Neptune® ARB™ System Introduced in 1964,the Neptune® Automatic Reading & Billing Sys tem Is the encoder register of choice for over 400 water utilities today.
r,
• Easily mounted to any Neptune® meter,the ARB'"encoder system transmits the actual register reading,In an electronic data format to a remote, accessible location.
• Proven reliability In over 4,000,000 Installations throughout North America.
ARB'" suits all applications: • ARB V'" for Indoor settings
• ProRead ARB'" for pit Installations and large meter vault settings. • ProRead ARB'" for reprogrammable, utility defined metering In formation.
For more information, Circle reply card No. 188
Schlumberger Reading Systems Schlumberger Industries Is dedicated to the development of fVleter Reading Systems that will maximize the efficiency of your water utility.
• Neptune® Unlgun'" System — specifically designed for data cap ture and management with the ARB'" system. Eliminates routebooks and data entry through a hand held mini-computer and PC based software system.
• Central Meter Reading(CMR'")— Schlumberger offers both Out bound and Inbound telephone based systems for single or multlutllltles.
• Introduced ARB'" data transmission through Radio Frequency at the '92 National AWWA Conference In Vancouver.
• Schlumberger guarantees compatibility of ARB'" encoder regis ters with our present and future reading systems.
For more information, Circle reply card No. 189
Schlumberger FloSearch™ System The FloSearch'" System Is designed for profiling customer water usage patterns.
• Applications Include leak detection, meter sizing, demand meter ing and peak usage studies.
• The FloSearch'"transmitter and FloSearch'"recorder continuously
ri
sample and record usage data. • PC based software generates reports of flow vs. time and water usage vs. flowrate In both graphical and tabular formats. • Usage data files may be exported to word processors, spread sheets, DOS,etc.
For more information, Circle reply card No. 190 ^Se/j/umbemeM
Schlumberger jIndustries
Schlumberger Industries
Measurement Division — Canada 7275 West Credit Ave.
Mississauga, Ont.
Regional Sales Offices 1209-59th Ave. S.E., 6555, boul. Metropolitain est, Suite 140 Suite 402, Caigary, Alberta St-Leonard, Quebec
L5N 5M9
T2H2P6
(416)858-4211
(403)253-0055
H1P3H3
(514)327-9998
For more information, Circle reply card No. 181
Technical Service Group 7275 West Credit Ave.
Mississauga, Ont. L5N 5M9
(416) 858-4211
UK Report
By Tom Davey
Royal Commission urges more monitoring of UK inland waters
While the European Com
munity's blue flag con troversy on the safety of Britain's ocean beaches
ways because its monitoring was'inade quate, subjective and piecemeal.' While the last decade has seen a
for bathers continues, a new study calls for more monitoring of the nation's inland waterways.
'small but real' deterioration in the qua lity of rivers in England and Wales, fol lowing an earlier two decade improve Professor Gareth Morris,a member of ment period, Britain relies too heavily the UK Royal Commission on Environ on its waterways as a convenient dump mental Pollution, launched a critical for waste, the report alleges. report Freshwater Quality* June 10, The People using inland waters for recrea study said the government had little tion and sport need the equivalent ofthe idea of the true state of Britain's water 'blug flag' scheme used by the EC to
designate safe beaches. Inland waters need such a scheme. For some reason,
the public had become very sensitive to water quality on ocean beaches, but lac ked the same sensitivity to fresh water areas where pathogenic organisms could be more durable. Professor Mor ris noted. Another commission member. Pro fessor John Lawton, said the commis
sion wanted a national monitoring and sampling program for British groundwaters. He called for biological mon itoring â&#x20AC;&#x201D; checking the health of life forms in and around the waterways â&#x20AC;&#x201D; rather than relying on limited chemical tests of the waters.
"It does not require a degree in che mistry to realize there are more than three kinds of things getting into the nation's waterways. Many aquifers were contaminated with industrial solvents
and leachate from landfdl sites,causing some authorities to abandon them as
drinking water sources," he said. The commission was critical of the
fact that there was no national program to check rivers and lakes for nutrient
discharges, such as phosphates, stem ming from agricultural and domestic wastes. Sewage treatment plants may have to be forced to strip out phosphates before discharging treated wastewaters into rivers, the report said. Small sewage treatment plants were singled out for being largely unaccountable for their discharges into streams. Indeed,a personal observation would
confirm this. While touring one inland canal in June, I noted some fish kills on a stretch of water downstream of a river
diversion which 'tops up'the canal sys tem as it loses water due to canal lock
operations. Anglers who regularly fished in the area said the fish kill was
sudden and severe,saying it almost cer
tainly had come from a pollution 'slug' entering the canal from the stream
British scientists from the Institute of Freshwater Ecology compare water colour images obtained from an airborne scanner in England'sfamed Lake District. Remote
diversion.
sensing estimates the concentration of algae by measuring the amount of light reflec ted from particles in suspension.The sensing can also help measure the'greenhouse effect.'The Lake District has other environmental roots.The poet William Wordsworth lived in the area, often visited by his friend Sir Humphrey Davy,the eminent chemist
meters of rivers in north-west England did not meet water quality targets be cause of untreated sewage overflows.
who invented both cathodic protection and the miners' safety lamp which did not explode in the presence of methane. His lab assistant, Michael Faraday, went on to
nowledged that the National Rivers Au
become the father of electricity and become both the first man to liquefy chlorine and the first to discover benzene in 1825. All modern electrolytic and electroplating pro cesses, as well as anything using electric motors, such as pumping stations, owe a debt to Michael Faraday's experiments with electrochemistry, electric currents and magnets.(See ES&E Oct.'91 â&#x20AC;&#x201D; page 13). 76
The report said that some 1,200 kilo
However,
the
commission
ack
thority was confronting many of the problems highlighted in the report. *Sixteenth Report of the Royal Commis sion on Environmental Pollution, Fresh water Quality', HMSG 57 pounds sterling.
Environmental Science & Engineering, July 1992
COMPLIANCE SOLUTIONS THAT PAY BY
AER-O-FLO ENVIRONMENTAL THE 4 R's ^' \
a/
• 98% Solids Reduction
• 98% FOGs Reduction
• 80% BODs Reduction
• $ Cost Reduction
Utilizing the Aer-0-Flo fully automatic Chemfloat system, food processors across Canada are experiencing dra matic reductions in solids, fats, oils, greases (FOGs), BODs and costs.
compact and operator friendly. It will treat your waste for dimes not dollars.
This low retention time, non-biological process is another guaranteed solution by Aer-0-Flo Environmental, where our product is your satisfaction.
The PLC controlled, low maintenance, com pletely stainless steel process is easy to install.
Aer-0-Flo — your environmental solution company
Aer-0-Flo Drumshear
Aer-O-Float
The Proof
Fine Rotating Screen
Flotation System
& The Pudding
AER-O-FLO ENVIRONMENTAL INC.
Your environmental solution company 1175 Appleby Line, Unit B2, Burlington, Ontario L7L 5H9 Tel:(416) 335-8944, Fax:(416) 335-8972 For more information, Circle reply card No. 182
Environmental Science & Engineering. July 1992
77
By Peter Baker*
Instrumentation
Development of flow measurement technology 3. The advent of the "smart" pres sure transmitter, has permitted greater flexibility when using square law den sity dependant flow meters (pitot tubes, orifice plates, etc.). The ability to re motely re-range D/P flow transmitters allows production plants to ensure opti mum accuracy of a flow element when process conditions or fluids change. Enhancements to the electronics por tion of the transmitter enable the trans
mitter to perform flow calculations (ie. square root, enthalpy, control) without extra equipment. 4, The largest revolution in flow mea surement has been the development of coriolis mass flow meters. These meters,
operating on the principle ofthe coriolis force (the same force that causes a boomerang to return), measure mass
Accurate flow measurements are vital to efficient wastewater treatment operations
Precise measurement of flow is becoming an increasingly cri
tical factor contributing to the quality of a manufacturing plant's output. Repeatable and accurate flow metering also impacts the financial and environmental success ofindustrial
processes.In the 1900"s. mechanical and positive displacement flow meters are quickly becoming obsolete and cus tomers are searching for alternate me thods of flow measurement. Electronic
flow metering technologies are rapidly developing to provide the accuracy, re peatability and reliability companies require to compete globally. The pub lished specifications of these new meters suggests that the "art" of flow metering has matured to an exact sci ence. Four methods of metering flow whose popularity has literally exploded in recent years are: 1 Magnetic flowmeters. 2 Vortex flowmeters.
3 Smart D/P transmitters.
4 Coriolis mass flow and density metering. 1. Magnetic flowmeters (magmeters) have been used in the process industries to meter conductive fluids since the
1950"s. The early popularity of mag meters was chiefly the result of the per formance of the AC type magmeter.The DC pulsed magmeter, introduced later, overcame some of the inherent limita-
"Account Manager, ABB Kent-Taylor 78
tions of the AC magmeter (quadrature voltage,phasing,heating,zero shift etc.). The DC pulsed mag was however
limited to relatively clean processes in which "hydro-dynamic" noise was not present. The AC magmeter was still used in these "tough" applications(slur ries. medium and high consistency pulp, etc,). Recent developments in DC pulsed magmeters have changed this. Several companies have introduced a new high power/high signal DC mag meter that provides the user with all the benefits of a DC mag and the excellent signal to noise ratio benefits of an AC magmeter. Additionally, advances in digital signal processing allow the DC magmeters transmitter(the secondary) to effectively reject spikes caused by, among other things, cationic substan ces (chelating agents etc,). 2. When vortex meters were first in troduced, to the market in the 1960"s
some developed a poor image. This image was the result of the method that vortex meters used to sense the fre
quency of the vortices. New frequency sensing technologies have permitted the vortex meter to accurately and reliably measure a broad range of processes. Vortex meters work well measuring high temperature processes, for example,
flow directly without being affected by changes in viscosity, specific gravity or flow profile. They do not require tem perature or pressure compensation and can deliver repeatable accuracies better than .2%. Recent developments in cor iolis metering technology have resulted in sensors that are virtually insensitive to ambient vibrations and electronics
that can provide simultaneous mass flow, equivalent volumetric flow, den sity, viscosity and temperature outputs. Some manufacturer's electronics can
also perform alarm and control (FID and batch) functions on any of these measured variables.
In today's competitive marketplace, accurate, repeatable and reliable mea suring equipment is a necessity of a modern manufacturing facility. Devel opments in flow measuring equipment, when properly applied, give the manu facturer or processor implementing these innovations a competitive edge. Ad Index Aco-Assman Aer-O-Flo
64
ISCO
77
Kent Taylor
21 22
Analytical Meas
Komiine Sanderson
52
Liquid Carbonic
Canviro Labs Ceiech
73 52 13 36 31 52 15 15 2 26 61
55 23 17 79 52 9 20 73 35 43
Degremont
73
Dominion Soil
52 30 80
Antlirafilter
Arts Mfg Supp Badger Meter Big 0 Can Am ins Can Ex Man Can Port Cem Assn
Cancoppas
Ego Equipment Eimco
Env Prot Labs Fenwick Labs
53
steam. The vortex meter is not affected
Goider
by changes in specific gravity; however, the viscosity of the process will limit the
Gorman Rupp Griffin Hach
minimum
Hazco
45 51 11 48 33 12 39 15 73
Hydrolab
38
down).
measurable
flow
(turn
Flyjt Geneq
Hatch
Macviro
Magnetrol Mann Test Labs Monitario
MSU Mississauga Munic Show National Ins NBC NBC Bobar
BobL 8. Summerville
Samuel Pipe Systems Scan Grodyne
40 8 5 24
Schlumberger
75
Soiinst
73 19 15 41 52 40 37 7 42
Summa Technitrol
Terminal City Terratech TBS
Victaulic Westech
Willms& Shier York Fluid Cont
73
For more information, Circle reply card No. 260
It'll cost you 11.5 million to get rid ofthis peak. So you'd better be sure it's real. All labs are not created equal.
like a track record. In business
Environmental decisions you make
For you, it's a matter of confi
since 1972, we number among our clients the government agencies that set the guidelines you have to
dence. Confidence that the facts
millions of dollars.
meetâ&#x20AC;&#x201D;and the consultants who
truth.
Mann's Quality Assurance and Quality Control program covers all aspects of sample processing. Sample integrity is rigorously recorded and controlled. Sample processing is continually recorded and monitored by our LIMS 3000 system. Sample test results are me ticulously validated via fortification studies, extraction blanks, analysis of replicates and much more. Assign your most important and challenging environmental testing
helped them set the guidelines.
based on less than reliable labora
tory results could cost you
you asked for are the truth, the whole truth, and nothing but the
To find out how Mann Testing Laboratories can be of service to
you, call us at (4l6) 890-2555. Or fex your request to(4l6)890-0370. Mann Testing Laboratories Ltd. 5550 McAdam Road, Mississauga, Ontario L4Z IPl. In western
Canada call (403) 462-6575 or our toll fi-ee number
1-800-563-MANN. The difference between accu rate and Mann-accurate is a matter
work to Mann. We are one of the
of experience, a matter of obses
few Canadian laboratories work
sive attention to detail, a matter of
MANN TESTING LABORATORIES LTD.
ing in this field that has anything
pride in doing things right.
QUAUTY RESULTS ON TIME.
For more information, Circle reply card No. 183
I' W"
m i m
SEPARATES PROBLEM it LIQUIDS EFFECTIVELY RESULTING CLARIFIED
OUTPUT MEETS and EXCEEDS
COMPLIANCE REGULATIONS f
chemicals
Depurator. Removes emulsified oil and suspended solids from water. Low cost, higti capacity. Efficient WEMCO Depurator flotation machines are used
extensively in the aluminum, petroleum and petrochemical Industry for wastewater and process water treatment.
Wastewater
Pacesetter. Used for oil/water
Silver Band. High performance
separation in oil production applications, and for liquid/liquid separation in chemical production facilities. Unique Propack'" crossflow plates achieve 99% efficiency with gravity-flow separation. Compact, high capacity units have low operating and
fouling, cleans water with 99% efficiency. Low media replacement rate. Fast (14 minute) media cleaning cycle. Simple installation, low
maintenance costs. Pressurized
maintenance.
down-flow media filter removes
suspended solids and hydrocarbons from produced water. Shell media resists
units available for specific applications.
Separation and Filtration Equipment for Municipal and Industrial Operations Process
EIMCO Equipment A DIvlaJon of Bakor Hughes Canada Inc.
5155 Creekbank Road
259 Midpark Way S.E.
Misslssauga, Ontario
Ste. 220
4940 Chlsholm St., Ste. 1 Delta, B.C.
L4W 1X2
Calgary, Alberta T2X 1M2 Tel:(403) 256-6821 Fax;(403) 256-7071
Tel:(604) 946-0421 Fax:(604) 946-7837
Tel:(416)625-6070 Fax:(416)625-3519
V4K 3X2
For more information, Circle reply card No. 184
1 Holiday Street 5th Floor, East Tower Point Claire, Cue. H9R 5N3 Tel:(514)695-9531 Fax:(514)695-8099