Previews of BCWWA•PCAO•AWWA•AWMA•Toronto Envt. Show meetings Private labs fight back,form lAETL Canada — an ES&E photo report Who speaks for our engineers & chemists? — an editorial comment
Biosolids handling options — an international perspective Air pollution across Canada — how are our provinces doing? Cobourg treats landfill leachate
FOR A SAFE ENVIRONMENT CALL US! Ammonia & Nitrate
Sludge Blanket
Parts Per Million
Monitors
Level Detectors
Dissolved Oxygen Analyzers
The only blanket interlace monitor/controller which automatically retains a clarifier blanket
Microprocessor-based dissolved oxygen ana
Interface following a disturbance, exhibits continuous clarifier profiles on a computer and controls up to four sludge pumps auto
bration, self-diagnostics, stepped current
Contronic Development's Ammonia Monitor Is based on use of an ion-selective electrode which measures the concentration of ammo
nia. The principle used involves raising the pH of the sample by the addition of alkali to con vert ammonium ions to ammonia. The instru
ment's microprocessor converts the electrode output signal to calculate ammonia concentration, while compensating for the temperature of the sample. The result is dis played as Nitrogen {NH4-N).
lyzers with features such as automatic cali output control, low cost multi-channel elec
tronics, and low maintenance self-cleaning
matically to maintain the desired interface
probes. Four channel conversion available. Request Bulletins 9010/9040 and 64/90.
level. The Model 2500 has no moving parts and can be virtually maintenance free. Request Bul letin 2500. Circle 201 on Reader Service Card
Circle 203 on Reader Service Card
Amperometric Chlorine Residual Analyzer
Circle 202 on Reader Service Card
BATTERY POWERED HAZARDOUS AREA SAMPLER ISO 9001 CERTIFIED
EFFLUENT SAMPLER
A WORLD FIRST IN RISK-FREE
The EPS 1021 Effluent
Sampler is designed to extract samples of liquid from an open channel or tank and deposit them in either a single composite container or sequentially into an array of
WASTE WATER SAMPLING The 1511 Zone 1 portable
waste water sampler is a
B O (<
unique world first — the
24 X 1/2 litre containers
only electrically operated (with intrinsically safe power pack) sampler of its type which is fully
for subsequent retrieval and analysis.
approved for Zone 1
Typical Applications * Crude sewage
hazardous environments,
Check these features:
providing an alternative to traditional pneumatic samplers.
ay Economical
(uses inexpensive non-toxic/non-hazardous butter) IC Low Maintenance
* Settled sewage * Final effluent
* Raw sludge
' Most industrial effluents
MEETS ALL INTERNATIONAL STANDARDS
(sell cieaning cell)
ay Easy to Install Q'Continuous sampling
ISO 9001 CERTIFIED
The 1511 complies with the many international safety
(SOmi/min)
EPS 1021
standards and is certified
ay Meets EPA Requirements
Effluent Sampler To MISA Specifications
by BASEEFA for use in
(40CFR 136 table IB Nol/17)
Zone 1 environments with
ay Unaffected by pH Swings
Circle 223
(up to 1pH)
the following classifica
Circle 224 on Reader Sen/ice Card
tions, E Ex ib MB t4.
ay Operates without need for buffer
AUTOMATIC LIQUID SAMPLING
(raw waterpH up to 7.2)
SC Wide Operating Range (.OOlppm to tOOppm)
Circle 680
WHEREVER IT'S NEEDED
SLUDGE SAMPLER
Aulo-Pacing Valve
The EPS 1030 Sludge Sampler is designed to extract samples of sewage sludge from a flowing pipeline or alternatively from a
Wide Range of Applications
□ Low cost
□ High Quality □ Easy to Install
ISO 9001 CERTIFIED
The Epic lOUT programmable portable
sludge holding tank via the tank wail. The machine represents the only really practical method of
wastewater sampler
□ Universal
provides cost effective
□ Linear
I automatic sampling to
□ Low feed capability □ Controls over-feeding □ L.E.D. Display □ WIN atrtomate any gas
acquiring sludge samples on a
■■ assist in monitoring municipal and industrial
regular basis and is unique in its
ability to sample sludges
wastewater.
.
chlorlnator
FOXCROFT
containing a high level of nonhomogeneous suspended solids.
A general purpose unit designed to extract samples of most liquids including crude sewage and even some sludges from an open source and to deposit them Into a container or sequentially into an array of 12 or 24
Typical Applications
* Anaerobic digester feeds/ contents/outputs
* Mechanical dewatering device feeds
* Road tanker loading/ discharge terminals
separate containers for subsequent analysis.
* Sea tanker loading terminals * Consolidation tank feeds EPS 1030
Sludge Sampler
Circle 226 on Reader Service Card
ISO 9001 CERTIFIED
Circle 227 on Reader Service Card
EXCLUSIVE CANADIAN REPRESENTATIVE
CANCOPPAS LIMITED
1045 SOUTH SERVICE ROAD, OAKVILLE, ONTARIO L6L 6K3 TELEPHONE (416) 847-2740 FAX 416) 827-6984 For more information, Circle reply card No. 260
Environmental Science & Engineering, March 1993
ISSN-0835-605X Editor and Publisher TOM DAVEY
February/March 1993, Vol.6 No. 1 Issued March, 1993
CONTENTS
(416) 727-4666 Associate Editor SANDRA DAVEY Sales Director STEVE DAVEY
(416) 727-4666 Sales Representative PENNY DAVEY (416) 727-4627 B.C. Sales Representative RON GANTDN (604) 274-3849
Technical Advisory Board Robert B. Baker, M.A.Sc., P.Eng.
Every drop counts — Canada's first national
16a
conference on water conservation
By Rod Holme Conference Previews — AWWA,BCWWA,AWMA,PCAO,
Toronto Env. Show
A\IU
The value of water demands realistic pricing mechanism
By The Hon. Jean Charest
IO
^
Totten Sims Hubicki Associates
Allan Church, C.Chem.
Church & Trought
Behind the smokescreen: the state of Canada's air
A Pollution Probe Report
20
George V. Crawford, P.Eng. Gore & Storrie Ltd.
Robert Ferguson, P.Eng. Metro Toronto Works Dept. Dr. Howard Goodfellow Goodfellow Consultants Ltd.
Rod Holme, P.Eng.
Tough new regulations for Ontario's pulp and paper Industry 22 Biosolids disposal — an International overview of current
^^
and future trends
By Brian Evans
Proctor & Redfern Ltd.
Peter Laughton, M.Eng., P.Eng. DEE R.V. Anderson Associates
Staff training In health and safety Is vital By David A. Whaley
34
Mike Provart, M.Sc., P.Eng. M.M. Dillon Ltd.
Dr. Earl Shannon, P.Eng. CH2M Hill Engineering Ltd. R. Bruce Smith, LL.B. Blake Cassels Graydon Environmental Science & Engineering is a bi-monthiy business publication published by Davcom Communications inc. An ail Canadian publication, ES&E provides au thoritative editorial coverage of Canada's municipal and industrial environmental control systems and drinking water treat ment and distribution.
ES&E's readers include consulting engi neers, industrial plant managers and en gineers, key provincial and federal envi ronmental officials, water and waste-water treatment plant operators and contractors. ES&E welcomes editorial contributions
but does not accept any responsibility whatsoever for the safekeeping of con tributed material. Environmental Science
& Engineering, 10 Petch Or., Aurora, Ontario, Canada, L4G 5N7, Tel; (416) 727-4666 Fax:(416)841-7271. All advertising space orders, copy, art work, film, proofs, etc. should be sent to EnvironmentalSciences,Engineering, c/o Pro-Art Graphics, 70 Ferrier St. Markham, Ontario, Canada, L3R 2Z5, attn: Gary Welch
Global environmental market could reach
44
$454 billion US by year 2000 By James Higgins
Laboratories fight back with the formation of lAETL Canada
A'A
By Tom Davey
"*3
Toxiclty monitoring using on-line resplrometry By Terry Innes A review of government and private laboratories legislation and data quality
64a
By J.N. Bishop
64b
Cobourg finds landfill leachate solution By G. Scott
64d
Combined use of heat and oxidants for controlling Zebra Mussels
74
Departments
Industry Update
8
Product Review
R&D News
39
Reader Service Card
Classifieds
62
Literature Review
49, 59 56a
69
Canadian Publications Mall Sales
Product Agreement No. 181897 Second Class Mall
Registration No. 7750 Printed in Canada, by Pro-Art Graphics Ltd. No part of this publication may be rep roduced by any means without written permission of the publisher. Yearly subscription rates: Canada $45.00 for one year, $80.00 for two years, $8.00 per single Issue; cheques must accom pany subscription orders. Directory & Buyers' Guide $35.00.(G.S.T. extra)
Canadian BimoMt Ml Prvu
Cover photo shows the Lemieux Island Water Purification Plant, which serves the nation's capital. Currently under way is a $51 -million,six-year program,which began in 1989 to rehabilitate the plant and expand capacity to 400 fvlL/d. Major process works include a new low lift pumping station and six dual media filters. The low lift pumping station, now nearing completion, has been designed to accommodate an ultimate capacity of600 M L/d.The filters are expected to be constructed in 1994.The expansion is designed by Gore & Storrie Limited, which also designed the first 190 ML/d plant in 1929. See story on p. 70. Information presented in ES&E is collected from a variety of sources presumed to be accurate and complete. ES&E cannot be held responsible for the accuracy of the information presented. Readers are encouraged to contact authors, agencies and companies directly for verification and/or clarification. Material in ES&E only conveys information and should not be considered as legal or professional advice.
Environmental Science & Engineering, March 1993
Editorial Comment
By Tom Davey
What about the voice appropriation of environmental professionals?
The world ofarts and let ers has entered a new area of con
work included Joan ofArc, was a multi ple'voice appropriation'offender,being
troversy: voice appropriation,
neither female nor French. Worse still,
the very latest fashion in politi cal correctness. Apparently women should not appropriate the voices of men
he was actually an Irishman with a su perb command of English. He used his genius in Pygmalion when he created the cockney flower girl Eliza Doolittle, a clear cut case of voice appropriation.
when they create fiction; black men
should not capture the voices of white males and presumably tall whites should not write about short men.
If a picture can be worth a thousand words then a rejected painting vividly illustrates the voice appropriation phe
Then, as if to rub it in to the cultural
giving Shaw several cultural canon law citations.
The Canada Council, the closest
thing to cultural nationalization that we have, has examined the 'voice approp riation" issue. One report stated that, while formal guidelines were not the answer, "There should be a recognition that cultural appropriation is a serious is sue and requires ongoing debate by staff, juries and advisory committees, as well as the artistic community at large." As these Canada Council juriesjudge funding applications, the directive is a compelling warning to those writers and artists who are not yet fully weaned from their state stepmother. But the cultural community is not without its own powerful voices of rea son. The 'voice appropriation' issue re ceived a brilliant rejoinder from the pen of Alberto Manguel, 1992 winner of the Canadian Authors' Association Award
for his novel: 'News from a foreign country.'
"Cutting one person's tongue would not give another a voice, but turns the silencer into a dictator", he wrote in a
Globe & Mail column prior to his award.
He wrote that priests in ancient Egypt once held prerogatives on certain sub jects; that Chinese emperors had exclu sive use ofsome colours and that in Nazi
Germany, Jews were forbidden to write about'German' subjects. This moved me to ponder a possible ban on Charles Darwin â&#x20AC;&#x201D; after all he
was not a monkey,even though he based his Origin of Species on the primates. Then my thoughts,too, began to evolve. I wondered about the staging oiHamlet, Shakespeare, not being Danish; then we might stop reading Gibbon's Decline and Fall ofthe Roman Empire,the author being English, not Italian. George Bernard Shaw, whose body of
than PCBs. But benzene has also been found in
analytical chemist that we can detect benzene at all, at the trace levels found
in drinking water. It is possible, likely even, to ingest a thousand times more benzene in a single day from breathing
told that, as a white woman,she "ought not to be painting coloured women at all." Writers also received similar stric
more toxic than PCBs. Benzene, for
example, a known carcinogen, is but one of several toxic compounds found in gasoline which are far more lethal
commissars, Pygmalion was reincar drinking water in minute quantities.In nated in the cinematic \nt My Fair Lady, deed it is only through the skill of the
nomenon. Artist Lyn Robichaud was
tures.
The protesters seemed blissfully un aware that the cars they drove contained chemical compounds which are far
For over two decades we
have been subjected to a deluge of drivel about environmental matters. The
spectre of polychlorlnated biphenyls(PCBs)has been repeatedly invoked to terrify society about risks which usually bear little relevance to epidemiology or toxicology.
downtown urban air,than one might get from drinking municipal water supplies during the same period of time, yet I have never heard any media activist put these health risks in perspective. In spite of viewing countless hours of environmental TV coverage, I have sel dom seen an engineer â&#x20AC;&#x201D; other than a token academic â&#x20AC;&#x201D; among the legions of talking heads commenting on ecologi cal issues. And despite the millions of words written about dangerous chemi cals,I have never heard a single analyti cal chemist quoted, or interviewed, in newspaper articles or on TV. What we have seen, ad nauseum on TV, are the
viewpoints of certain media environ mentalists, most of whom would be for
With his great love of phonetics and unmatched insights into English ac cents,Shaw was literally one ofthe great voice appropriators of all time. And he used his great literary gifts to campaign against war, poverty, social injustice and pomposity. But has anyone ever commented on the voice appropriation ofenvironmen tal engineers and chemists? For overtwo decades we have been subjected to a deluge of drivel about environmental matters. The spectre of polychlorlnated biphenyls (PCBs) has been repeatedly invoked to terrify society about risks which usually bear little relevance to epidemiology or toxicology. In one case, media hype by British tabloids resulted in a shipment ofCana dian PCB wastes being rejected in Lon don. Like some voyage of the damned, the unfortunate ship returned across the Atlantic to sail up the St. Lawrence."Vio lence erupted at Bale Comeau as protes ters tried to block the PCBs from being returned to Canadian soil. Ironically, the PCBs probably posed a lesser threat than the jostling crowds waving picket signs.
bidden, by law, to operate, let alone design, pollution abatement facilities. Environmental professionals have rightly concluded that their technical knowledge is best leavened by exposure to other, less focussed views. They have acknowledged that their critics, includ ing the arts fraternity, might well endow their scientific training with a broader, more ecosystemic vision. In short they feel they can learn from other 'voices' and viewpoints. For example. Dr. David Suzuki was a keynote speaker at a recent Western Canada "Water & Wastewater Associa tion Conference in Edmonton and
Colin Isaacs, formerly Executive Direc tor of Pollution Probe, was keynote speaker at the'92 AWWA drinking water conference in Niagara Falls. Seldom does either speaker spare their hosts from criticism.
Environmental professionals also in vite reporters and TV producers to par ticipate in, as well as report on, their conferences. This willingness to hear other voices shows a wisdom and gener osity of spirit which our cultural and media mandarins might well emulate.
Environmental Science & Engineering, March 1993
Continuous Emission
Westech provides a single sourcefor all your C.E.M. needs ... •Applications Engineering •Staff Training •Systems Design • Qualified Service
Monitoring
• Testing •Start-up & commissioning Whether you require a simple single component system or a complete multi-componentpackage with data acquisition and mass flow, Westech is the choicefor today's environmental needs.
The Westech
•Assembly
• Installation
•Fabrication
Solution
Measured components include: NO,N0„ NOx,SO2,Hfi,TRS,HCl, HE,HCN, Ck, C10„ CO,, CO, 0^, THC,VOC,Opacity aruiMassFlow. Whateverthe problem,Westech has the experience and the equipment to provide the solution.
Westech has been Canada's
leading packager of Analytical Systems for Process and Environmental Measurement in
air and waterfor 25 years.
HALIFAX
MONTREAL
TORONTO
SARNIA
REGINA
CALGARY
EDMONTON
VANCOUVER
TEL:(902) 865-5486
TEL:(514)367-4036
TEL:(416)890-5265
TEL:(519)383-6320
TEL:(306) 757-5006
TEL:(403) 252-8803
TEL:(403)464-4740
TEL:(604) 278-5112
FAX:(902)865-2137
FAX:(514)631-0857
FAX:(416)890-6213
FAX:(519) 383-6322
FAX:(306)757-2205
FAX:(403) 253-6803
FAX:(403) 467-1605
FAX:(604) 278-5126
For more information, Circle reply card No. 139
Ne
Introducing the CENTRIPRESS™ Advanced Dewatering System.(ADS) The new CENTRIPRESS™ ADS Series
design increases capacity by up to 50% when compared with an original CENTRIPRESS™ System of comparable size. This is significant since the original CENTRIPRESS™ System has set the standard of performance in "High Solids" dewatering since 1986. The new technology has been developed and proven in full scale sewage operations in Europe, and is now available in the U.S. and Canada exclusively with the Humboldt CENTRIPRESS™ ADS Series.
Here's what's new about the CENTRIPRESS™ ADS Series:
Improved design of feed and polymer addition systems. Up to 50% more throughput per machine size with "High Solids" performance. Lower power consumption per GPM of feed.
Higher torque capability. Decreased space requirements. Offered in a range of capacity sizes to match your plant flow needs. Look into this improved technology before you write your next dewatering specification
Look to Humboldt technology for better performance
i
m
Introducing the Humboldt BIOLIFT™ Advanced Thickening System. A patented process which brings new technology and new levels of performance to WAS thickening.
The Humboldt BIOLIFT^'^ System is highly adaptable and can handle a wide range of flow rate and feed concentrations without
time- consuming shutdowns. Performance of the Humboldt BIOLIFT'^
System is automated to require little or no operator attention.
Here's what's new about the Humboldt
BIOLIFP^^ System: • Positive air pulse control of solids discharge.
• Minimal sludge blanket in clarification zone for better recovery. • Closed-loop, fully automatic control adjusts to changing feed conditions. • Increased capacity with lower power consumption. • Single unit capacities to 1500 GPM. Look to Humboldt BIOLIFT'^ technology for more cost-effective WAS thickening.
Control & Metering Ltd. One Westside Drive, Toronto M9C 1B2
(416)626-8411 Humboldt Decanter Inc.
3200 Points Parkway, Norcross, GA 30092 (404)448-4748, FAX (404)416-9377
HUMBOLDT
A KHD
For more information, Circie repiy card No. 141
Industry update
Sewer
Anywhere and Save
Big 'O' Inc. signs Mexican joint-venture agreement Big 'O'Inc., a Canadian company spe cializing in the manufacture of cor rugated High Density Polyethylene pipes used in liquids gathering and con trol systems, announces the signing of a Joint-Venture agreement which will lead to the manufacture of pipe in Mexico.
The Environment One Grinder
Pump powers the low pressure sewer system providing wastewater storage, grinding and pumping in a single unit. Utiliz ing small diameter sewer piping (32 mm -100 mm),shallow buried to the terrain contour,
the Grinder Pump station can discharge the wastewater verti cally more than 28 metres or move it horizontally up to 3.3 kilometres.
The Agreement, signed with Tubos y Elementos Presforzados, S.A.(TEPSA) of Mexico City, provides for the transfer of Canadian technology and manufac turing process knowledge developed by Big 'O' over the last 25 years, together with training and on-going assistance in the operations of the business in Mexico.
The initial capital equipment that will be supplied by Big 'O" and other Cana dian companies will exceed $10 million. It is expected that future equipment sales to this venture will be significant as the Joint-Venture participates in the strong Mexican market for infrastruc ture products. The signing of this Joint-Venture agreement follows the commitment that was made by Big 'O' to pursue inter national markets for its technology,and has been encouraged by the oppor tunities that have been given to Cana dian companies under the provisions of the North American Free Trade Agree
Ontario Clean Water Agency.
The primary goal of this new Crown corporation will be to help municipali ties plan and develop water and sewage services in a way that protects human health and the environment. The agen cy will encourage the conservation of resources by promoting efficient use of existing facilities and will support pro vincial land use planning and growth and settlement objectives.
The Ontario Clean Water Agency will operate and maintain existing provincially-owned water and sewage facilities throughout Ontario and will develop new facilities, as needed, to meet future
water and sewer demands. The agency will enter into partnership with local governments by providing assistance for upgrading and new development of municipal water and sewer services. It will help co-ordinate and finance large projects shared by neighbouring mu nicipalities.
The agency will assist municipalities to plan and to develop water and sewage systems that will meetcurrent needs and future demands. It will be a source of
technical advice for the municipal sec tor, providing support for the improved efficiency of the operation of municipal water and sewer systems and for water conservation
measures. This Crown
corporation will be formally established through legislation.
Oxygen reduces
ment(NAFTA),
"Big 'O" was the first Canadian com pany to recognize the enormous poten tial for large diameter corrugated poly ethylene pipe for use in liquids gather
chlorine In Alberta
ing and control systems.The knowledge that has been developed in this market area is now providing the company with significant international market oppor
Praxair Canada Inc. (formerly Linde year, multi-million dollar contract to supply 31 tonnes a day of liquid oxygen
tunities, of which Mexico is the first to
to Alberta Pacific's new mill in Pros
be concluded," said Grant Kime, Presi
perity. The oxygen will be used by the
pulp mill Canada) has just been awarded a five-
dent of Big 'O' Inc., in Exeter, Ontario. mill for oxygen delignification, white Big'O'anticipates the Mexican JointVenture will create and maintain 50jobs in Canada and provide the resources required to continue the development of technology for use in Mexico and other international jurisdictions. Big'O'expressed gratitude for the as sistance provided by Townsend Trade Strategies of Ottawa and Toronto who conducted the initial assessment of the
Call us today for more information; 416 845-4209
Ontario Sewage Equipment 20 Shepherd Road
Mexican market opportunity, guidance on the search for the Joint-Venture part ner, and assistance in the development of the business agreements.
Ontario Forms
liquor oxidation and oxygen extraction bleaching. Alberta Pacific will be the first Alberta pulp mill to use oxygen for white liquor oxidation, "Not only will the oxygen save costs, compared with traditional chemicals used in the pulp bleaching process, it is more environmentally beneficial by re ducing or eliminating chlorinated or ganic compounds," according to Michael E. DeDomenico, President of Toronto-based Praxair Canada Inc,
This was extremely important to Al berta Pacific as ajointfederal/provincial environmental assessment board was
Clean Water Agency
Oakville, ONL6K2G5
On February 9,1993,the Premier ofOn
Fax: 416 845-6321 Circle reply card No. 142
tario announced the creation of the
concerned about the potential dis charge of chlorinated organic com pounds into the Athabaska-Peace River system, he added.
Environmental Science & Engineering, March 1993
Industry update in small quantities might damage ner
Mercury free batteries
vous systems and, perhaps increase the
will reduce landfills'
risk of cancer.
toxic loading Battery Technologies Inc.(BTI) and the Ontario Ministry of Environment have announced successful completion of BTI's project to eliminate mercury from the new Rechargeable Alkaline Man ganese(RAM)battery system. Aded in
part by the Ministry's Environmental Technologies Program, BTI, through a patented process, has successfully manufactured and demonstrated mer
cury free RAM batteries in both labora tory and large scale commercial quantities. Traditionally mercury has been used in alkaline batteries to control the evolu
tion ofinternal gassing. Recently the use of mercury and other heavy metals found in batteries, including lead and cadmium, have come under close scru
tiny from government regulators and legislators because of health hazards and environmental implications. According to the Canadian Stan dards Association,over 13 metric tons of
mercury from batteries are disposed of annually in Canada. In the United States,an estimated 170 tons of mercury, 200 tons ofcadmium and 260,000 tons of lead,contained in used batteries are dis
carded annually.These metals may leak into ground water tables and,if ingested
As a low cost 1.5 volt alkaline battery with a 3-4 year shelf life. RAM products are completely interchangeable with today's household batteries. The elimi nation of mercury together with the re usable nature of RAM products will provide consumers with a more econo mical and environmentally safer alter native to both single use and recharge able Nickel Cadmium consumer bat teries.
BTI is licensing the manufacturing and marketing rights of the RAM tech nology to companies worldwide. To date, licenses have been signed by com
vestment is expected to create about 8,000 jobs. The announcement is part of a series of capital investment plans revealed by the Premier. Mr. Rae said about $6 bil lion will be invested in Ontario infras
tructure over the next ten years and create more than 100,000 jobs. He said that, ofthe $258 million allot ted to water and sewer facilities, more
than $90 million will be spent in 1993-94 in support of 120 projects and will put about 2,800 people to work. Mr. Rae praised the participation of Ontario municipalities in sharing the costs of developing new sewer and water facilities. However, he said, there was a
panies in Canada, Australia. Hungary and two in the US,including the Rayovac Corporation.
"growing realization" that the private sector could be an important partner in future projects. The Premier noted the participation
JobsOntario commits
lion expansion of the Ingleside sewage
of Kraft General Foods in the $12.5 mil
$258 million for sewer and water construction JobsOntario will invest $258 million in
treatment plant. There, in addition to a provincial contribution of $6.1 million and funding from Osnabruck Township of $1.4 million, Kraft is contributing $5 million,
the upgrading and construction of new sewer and water facilities throughout
Haion's phased out for fire extinguishers
Ontario. Premier Bob Rae said at the
Ottawa-Carleton
Regional
Offices.
Feb. 1.
With municipal and third party par ticipation, over $400 million will be spent over the next four years. The in-
Banning halon fire extinguishers may aid the ozone layer â&#x20AC;&#x201D; but increase the dangers of fire. continued on page 10
SLUDGE DEWATERING SERVICES
A COMPLETE SERVICE â&#x20AC;&#x201D; Reduce your sludge disposal costs by mobilizing the TRIMAX HI-SPEED CENTRIFUGE DEWATERING SYSTEMS for your next dewatering project. For Further Information Contact:
TRIMAX ENVIRONMENTAL SERVICES LTD. Phone:(403) 466-7920 Environmental Science & Engineering. March 1993
Fax: (403) 469-4465 For more information, Circle reply card No. 231
Industry update A recent agreement by 87 countries to phase out the manufacture of halon fire extinguishers will eventually eliminate a potent threat to the ozone layer. But experts believe that the ban will make some fires harder to put out and could
severe than originally believed, the
Lt;l.. speaking at a press conference in
schedule has been advanced several
Toronto.
times since 1987. most recently on Nov. 25 in Copenhagen.
Has Toronto become
Quote
a satirist's dream?
Halons are up to 10 times more effec tive in putting out fires than other
"Ozone molecules each consist of three
"Tax revolt is in the air... Just about every
oxygen atoms which protect us from the
chemicals.
harmful effects of the sun's ultra violet
Halons. unlike other fire extingui shers. not only extinguish fires swiftly but are chemically inert, nontoxic. and harmless to delicate equipment,includ ing computer circuits. No other extin guishers combine all these features. Like the chlorofluorocarbon (CFC) chemicals widely used as refrigerants,in
rays. CFCs in the stratosphere are mical compounds, the most significant of which is chlorine. Chlorine strips one oxygen atom from the ozone molecule leaving one oxygen molecule. Free oxy gen atoms exist in the stratosphere which combine with the oxygen atom
aspect of Toronto governance seems to be in the grip of political crazies, from officials in the NDP provincial govern ment down into the Metro and local city governments. No satirist could imagine the gallery of Napoleons. Trotskyites.
sulators and solvents, the halon chemi
attached to the chlorine atom. This re
overgovernment," says the Globe &
cals used as fire extinguishers are so resistant to decomposition that once re leased. they can remain in the atmos phere for many years without break ing down. In 1987 an international agreement
sults in two oxygen molecules and frees the chlorine to destroy another ozone molecule. This process is repeated 100.000 times before that single chlorine
Mail's Terrence Corcoran.
cost lives.
broken down into their individual che
molecule is neutralized.
known as the Montreal Protocol set a
"Simply put — if all the ozone were brought down to the higher pressure
timetable for phasing out the produc
level at the earth's surface, it would be
tion and use of CFCs and a few other
compressed to the thickness of a 3 mm plate of glass. The chlorine atoms being released by the CFCs are in effect shoot ing bullet holes through that thin layer protecting us from the sun's harmful ultra violet rays." Bill Chalmers, P.Eng. HTS Engineering
ozone-destroying chemicals. The manufacture of halons is also to
be ended, although their use can con tinue until supplies are exhausted. But because the destruction of the ozone
layer has proved to be faster and more
Corrosion Fighting" Specialty Fittings ROBAR
Robar's specialty waterworks fittings are manufactured with corrosion-resistant
health fascists, environuts. dunder heads. socialists and numbskulls who
patrol the council meetings and back rooms of Toronto's various levels of
"Toronto-area politicians spend most of their time harranguing one another over senseless schemes. One notewor
thy example, from two Toronto city councillors ofthe NDP persuasion, was a plan to create an energy and water savings company.At a cost of merely SBbillion. or $14,000 per average con
sumer. the company would "retrofit" every home, office building, industrial structure and institution in the city for
energy efficiency. People would recover the cost in one year, said one of the councillors."
Reduce Sludge Disposal Costs By up to 60%!
coatings and materials ... a sample of these products are shown below ... 2606 All SUInless
The Original*
Steel Service
All StainlessSteel
Saddle.
Repair Clamps.
Bronze 2706 Saddles Corrosion Protective
With Wide SUlnless
Coating 1506 Couplings
Steel Straps.
With Stainless Steel Bolts.
The revolutionary Heliman-Spehr waste drying system significantly reduces sludge volume, which means reduced costs for waste haulage, dumping and/or incineration. Even dewatered sludge can be reduced by as much as an additional 70% • Effective on ail types of water based sludge or slurry. • Reduces liquid waste to a powder. • Envircnmentaiiy friendly system produces clean condensate as a by-product. • Low cost, energy efficient operation. • Non-polluting, closed loop system, with no exhaust to atmosphere. • Significant odour reduction.
• Modular design is expandable and can fit any size application. • Field-proven German technology, now manufactured in Canada.
Start saving today! Call us at(416) 231-9216 1
For further details, please contact...
ROBAR INDUSTRIES LTD. 12945 - 78th Avenue, Surrey, B.C. V3W 2X8 Phone (604) 591-8811 FAX (604) 591-5288 Toll Free 800-663-6553
10
For more information, Circle reply card No. 232
Bfwipr
BEP TECHNOLOGIES
245 Norseman Street
TECHNOLOGIES
1 A DIVISION OF BESTOBELL CANADA LIMITED
Toronto, Ontario M8Z 2R5
Tel ;(416) 231-9216 Fax :(416) 231-9121
See us at the Toronto Environmental Trade Show - booth #334 For more information, Circle reply card No. 233
Industry update UK cuts off late payers The numberofUKhomes disconnected
has almost trebled in the past year to 21,286. The Office of Water Services is
trying to find how many of these cus tomers are in real financial difficulties.
Ian Byatt, Ofwat's director, said: "These are very worrying figures." In the Central British region, the number of disconnections multiplied more than 10-fold to 4,797.
Miss Anne Taylor, Labours shadow environment minister, said: "The in crease in domestic disconnection is a
scandal. The water companies seem to be all too ready to cut off people's supply when disconnections should only be a last resort with the permission of a magistrate." She called on Mr. Byatt to take legal action to prevent prices rising so steeply. "Bills have to be paid," he responded. "I will not permit companies to raise their charges to cover their bad debts.
hold electric heater. When combined
with a system for extracting vapors from the soil, the method shows promise for speeding the cleanup process. A small scale test of the electrical
heating-vapor extraction method was conducted recently at the lab's Site 300 test site according to Michael Buettner, an electronics engineering group leader.
put in place at gas dispensing areas to clean up existing spills and to stop spilled gasoline and other petroleumbased materials from spreading through the soil to the ground water.
The Queen would not be amused
He said this was the first demonstration
London's drinking water contains pes
of the technology at a contaminated
ticides and 34 reservoirs are sometimes
site.
contaminated with sewage, the UK Drinking Water Inspectorate reported. Thames Water, the biggest supplier in
The test showed that the vacuuminduced extraction removal rate of the
common solvent trichloroethylene from soil was more than doubled by the addition of electrical heating. A large scale test is planned for later this year when electrical heating and vapor ex traction are to be combined with steam
injection for cleaning a gasoline spill from the soil and ground water at the Lab's main site in Livermore.
Buettner said such a system, when made economically feasible, could be
Britain, had the worst record of 29 water
companies studied.
Some 80 percent ofThames Water sup ply areas failed to meet statutory re quirements at least sometime during 1991, said the report. Since London is the largest UK water supplier, its record dragged down the UK average. Five per cent of all Thames Water samples failed to reach required standards compared to the national average of 1.3 percent.
This would not be fair to those who
have paid." Mr. David
Walker, Severn
Solace In Blunderland as
Trent
water board spokesman responded to the figures saying:"We always try to dif ferentiate between those who can't pay and those who won't pay." He added that the company had taken a relaxed position on late payers in the previous year, but was now catch ing up on some customers who have not paid for two and a half years. Mr.Byatt admitted that after the water industry was privatised, disconnections
Red Queen gets health folio cated the mine was ideal to accept railtransported garbaae from Metro Toronto
whichhad spentS5.6 million lookingfor a new dump and putting an option on the mine site.
Ironically, Mrs. Griefs policies have already resulted in Metro Toronto los ing some $225 million in tipping fees,
fell to a low in 1990-91 of9.205 before ris
ing to 15,255 last year and increasing by 177 per cent, in the later year. On average across Britain, one household in every thousand is discon nected each year â&#x20AC;&#x201D; though water com panies say that about 80% are recon nected within a few days. "So it looks like it's won't pay. rather than can't pay," said Mr. Walker.
Electrical soil-cleaning process A new technology for cleaning gasoline and other solvents from soil and ground water has been successfully tested at Lawrence Livermore National Labora
tory's Site 300 experimental test facility near Tracy, Calif., and may one day come to local gasoline station or minimart gas dispensing areas. Electronics engineers and scientists at Lawrence Livermore are perfecting the art ofenhancing cleanup of soil and ground water contaminants by heating the soil electrically. In this process,elec tric currents flow through the soil heat ing it up in much the same ways as the heating element in a common house
because she refused to stop private firms shipping garbage to cheaper dumps in the U.S. At the same time she was ada mant that York, Peel and Durham Re
gions mustbe considered as repositories for Metro's rubbish.
This is the same NDP government which opposes the North American Free Trade Act in its mission to protect I was delighted to learn that Ruth Grier Canadian jobs. So far the province has was recycled from environment to health spent $27 million in searching for new minister in the latest NDP cabinet shuf dump sites in areas which vehemently fle. She had repeatedly rejected pro resist them. Simultaneously she denied posals to dispose of Metro Toronto's the real job creation benefits the Kirk garbage in a disused mine at Kirkland Lake where some 70 jobs might have been created in an area of high unem ployment. "Municipalities must look after their own garbage," she said, while insisting that Regional municipalities â&#x20AC;&#x201D; just as politically autonomous as Metro Toronto â&#x20AC;&#x201D; must accept Toronto's garbage. The proposed new landfill sites com prise .some of the best, and incidently
land Lake site would bring to an area which badly needs them. In his classic Alice in Wonderland.
Lewis Carroll created the Red Queen, now cited the world over as the epitome ofconvoluted reasoning. While now out of the environmental folio, Ruth Grier
still holds a cabinet position which must give her solace in the NDP's blunderland. Now Ruth Grier is Ontario's new
some of the most beautiful farmland in
health minister,I wonder ifshe will insist
Canada. By contrast,the Kirkland Lake
that Toronto's hospitals accept only those patients who became sick within Metro's borders? Tom Davey
site is a barren, wOrked-out mine. Pre
liminary hydro-geological studies indi
Environmental Science & Engineering. March 1993
Business update New environmental consortium targets U.S. site remediation market
Jean Charest (left) with Ruth Grier and Dusanka Fillpovich (right)
Environment Ministers
help launch new CFC collection and
recycling industry Jean Charest. Federal Environment Minister and the then Ontario Environ
ment Minister Ruth Grier joined Halozone Technologies Inc. at the official opening of a new pilot facility in Mississauga, Ont. to capture, purify and recycle CFCs. The Ontario Ministry of the Environ ment is providing $894,066 under its En vironmental Technologies Program to
A new Canadian firm. North American Environmental Services Inc.. has been
five thousand. NAES founders include: Hector Jac
incorporated by a founding group of highly qualified environmental engin eering, contracting and technical ser vice companies to undertake property clean up work collectively outside of Canada, primarily in the United States. Companies with the required experi ence and skills, and a proven record of delivery and capability, are being in vited to participate in this enterprise.
ques. President, Jacques Whitford and Associates Limited, Halifax; Bernard
Poulin. President, Le Groupe S.M.. Montreal; Douglas G. Langley, Presi dent, Environment Protection Labora tories Inc.. Toronto; Dr. Michael J. O'Connor. President. O'Connor Asso
ciates, Calgary, and John Bennett, Pre sident, Bennett Remediation Services Inc., Vancouver.
The selection of firms is aimed at a
Douglas G. Langley, Chairman and
balance of complementary capabilities to thoroughly remediate environmen tally contaminated sites. When fully subscribed it is anticipated that 30 to 40 companies will participate with com
C.E.O. and John Bennett. President,
formally announced formation of the new company which is opening an of fice in Washington, D.C., in early 1993.
bined annual sales in excess of $500
For information contact David C. Graham at 301 Metcalfe Street, Ottawa.
million and a technical and administra tive work force of between four and
Ontario. Canada. K2P 1R9. Tel. (613) 232-1949. Fax:(613) 232-9343.
Scepter, Canron combine plastic pipe businesses
The newbusiness is owned equally by
both parties and will conduct business under the name Scepter/Canron Inc. Thomas Torokvei, of Scepter, has been appointed Chairman and Chief Execu
support the Halozone Blue Bottle™ pro
Canron Inc.. Toronto, a wholly-owned
ject over the next three years to help cap ture ozone-destroying chlorofluorocar-
subsidiary of Ivaco Inc., Montreal and Scepter Manufacturing Co. Ltd., Toron
bons.The Montreal Protocol,established
to, have jointly reported closing of the previously announced combination of the Scepter and Canron plastic pipe
ron. has been appointed President and Chief Operating Officer. Prior to the merger both companies operated coast-to-coast in Canada and
business.
were active in the United States market.
in 1987 by the United Nations, sets a 1995 deadline for ending international CFC production.
tive Officer and Paul Graddon, of Can
Choose The World Leader in On-site Remediation of Soil and Groundwater.
Full-Service Consulting and Remediation Contracting □ Environmental Assessments and Audits
□ Geology and Hydrogeology □ Engineered Solutions □ Cost-Effective Remediation
Technologies
□ Rapid Site Closures
Groundwater Technology Canada Ltd. / Ltee 65 Locations Worldwide
12
Mlssissauga, Ontario (416) 670-1700 Anjou, Quebec (514) 353-6939 Halifax, Nova Scotia (902) 453-0585
For more information, Circle reply card No. 234
Groundwater Technology
Environmental Science & Engineering, March 1993
Economic redevelopment Economic redevelopment plus environmental responsiveness are twin requirements of the 90s. G&S has the tools and expertise for the extensive long-term strategic planning required to achieve both sustained economic growth and ecological protection. Economic redevelopment doesn't have to come at the expense of the environment.
Beside the lake, beneath a park,Lome Park Water Treatment Plant in Mississauga is
North America'sfirst underground water works. It combines essential treatment ser
vices with aesthetic and recreational con
siderations â&#x20AC;&#x201D; plus unrestricted access to the lakeshore. This plant is unmanned, being remotely controlled from nearby Lakeview WTP. it
Environmental
responsibility Cost
effectiveness While pushing at the frontiers of technology
Our treatment plants and processes, while meeting the most stringent pollution abate ment regulations, are also energy-efficient, operator-friendly, and in harmony with their surroundings.
for innovative alternatives to environmental
problems, G&S
realizes that
Green Solutions must also be cost-effective. Cost-effectiveness
is delivered through energy-effi cient designs and low-mainten ance building systems.
Set between an urban community and the environmentally sensitive Joshua Creek, the 32,000 mVd Oakville South-East
WPCP quietly serves both residential and industrial communities of Oakville. Ontario.
Gore & Storrle Limited, Consulting Engineers, 255 Consumers Road, North York, Ontario, M2J 5B6
Telephone:(416)499-9000 Fax:(416)499-4687 With offices in Ottawa, Barrie, r\/lississauga, Thorold, Cambridge, Kingston, and London For more information, Circle reply card No, 235
Environmental Science & Engineering, March 1993
13
Industry update bottled water. The Southern Water au
Saab's drive for cleaner air A car that actually removes smog from polluted city air has been developed.
thority declined to compensate con
sumers, saying it had been diligent in alerting people and keeping them in
puter-controlled engine management
generation of vehicles comply with exist ing Californian emission levels, the toughest in the world, and even those proposed for 1999. Trionic uses a mic
system are cleaner than when sucked in.
roprocessor capable of making two mil
said:"Three years ago no-one was even
It causes less pollution running from New York to Los Angeles than a gas lawnmower cutting grass for two hours.
lion calculations a second. The micro
testing for cryptosporidium.We are now carrying out routine analysis, although we do not have to. Back in April we
The emissions from the vehicle's com
A demonstration of Saab's Trionic en
gine management system and direct ig nition proves that such a car scrubs clean the traffic-polluted air that it takes in.
Engineers directed exhaust from a 40year-old two-stroke car emitting blue smoke straight into the air intake of a Saab 9000 fitted with the Trionic equip ment.
A pollution sensor was set up in the new car's exhaust. Pollution readings were a fraction of those of the fumes at the intake.
The Trionic system means Saab's new
CIDA drainage project for UMA UMA Engineering and a joint venture partner. W-E-R- Engineering Ltd. of Calgary recently concluded contract negotiations with the Canadian Inter national Development Agency(CIDA) to undertake an integrated five year drainage research project in the State of Rajasthan. India. The Rajasthan Agricultural Drain age Research Project(RAJAD)is a joint undertaking of the Canadian Govern ment and the Rajasthan State Govern
processor controls engine combustion by simultaneously monitoring and ad justing the ignition, timing, fuel injec tion and turbo boost pressure hundreds of times a second.
The microchip at the heart of the sys tem was first developed by General Mo tors of America. When CM took a 50 per cent stake in Saab in 1990 the chip be came available to Saab engineers, who advanced it significantly. Together with Trionic. Saab uses di rect ignition, which gives a more reliable multi-spark at every plug.The condition within every combustion chamber is monitored for optimum performance using a "super sensor". failures.
Some residents of the Isle of Wight discovered that compensation for water contamination is not guaranteed. Some 18.000 people living on the island had to boil their water for five days because cryptosporidium had contaminated the water. Customers had to boil or buy the
formed.
A spokesperson for Southern Water
detected it and immediately gave war
nings. We feel we have done ourjob and that preventative medicine is better than compensation afterwards. Of course, if there were regulations saying we should make a cash payment to customers who were affected we would be happy to abide by them."
A guaranteed standards scheme was agreed with the water companies when the industry was privatized in 1989. But in May OFWAT,the industry watchdog, proposed a revised scheme and a new code of practice about compensating customers. New regulations to the Sec retary of State for the Environment may be made. At the moment the existing scheme provides for a flat rate payment
of5 pounds in respect of each failure to meet guaranteed standards. Payments have to be claimed in writing by the cus tomer within three months of the inci
dent. There is nothing about compen sation in case of contamination.
ment. Canada's commitment is $62.07
million over a five year period. The 25.000 hectare drainage research initiative will be the first major applica tion of horizontal subsurface drainage technology in India. In addition to Ca nadian engineering and other pro fessional expertise provided through the UMA/W-E-R Joint Venture, CIDA
will also utilize the expertise of Cana dian drainage contractors to install over 10.000 km of drain piping. The project at peak will provide twenty Canadian professional advisors and researchers in the disciplines ofirri gation. drainage, and environmental engineering, human resources, social anthropology, agricultural economics, agricultural extension, agronomy, in strumentation and controls,soil science
and hydrogeology.
No compensation The UK Drinking Water Inspectorate
has reported that 98.7 per cent of 3.57 million water samples tested last year were acceptable. Thames Water author ity scored the highest proportion of 14
Polyethylene Sheeting Being Manufactured at Columbia's Calgary Plant
Technical Support Columbia supports consulting
Total Containment Solutions Columbia offers North American
engineers with technical data, budgetary cost information and
facility operators 20 years' experi
alternative containment solutions.
for environmental containment
ence in creating leak-free solutions
problems. Total Responsibility Columbia is Canada's only manu facturer of wide polyethylene sheeting. Columbia also installs long-life liners and liner covers using the unique Columbia weld system.
1415 28th St. N.E., Calgary, AB T2A 2P6 Tel:(403) 273-5152 Fax:(403) 235-6864
COLUMBIA
m
GEOSYSTEMS
"Columbia for long-life environmental protection"
For more information, Circle reply card No. 254
Industry update Du Pont launches CFC substitutes In the us,Du Pont has announced com
mercial availability of three products to replace chlorofluDrocarbons(CFCs)in commercial refrigeration applications such as supermarket display cases and freezers, in refrigerated transport sys tems and in ice-making machines. The nonflammable substitutes are
the latest additions to Du Font's family of"Suva" refrigerants and follow start up of the company's facility in Deepwater, N.J., to produce millions of pounds annually of hydrofluorocarbon (HFC)-125.Two of the products,"Suva" HP80 and "Suva" HP81, are blends of
hydrochlorofluorocarbon (HCFC)-22, HFC-125 and propane (R-290). They are 90 percent less ozone depleting than R-502, the CFC-containing product they replace, and offer an 80 percent reduction in global warming potential. The third alternative,"Suva" 125, is a
non-ozone-depleting product targeted to replace R-502 in other low tempera ture applications. These latest products offer super markets, in particular, an immediate option to move away from the CFCbased R-502, says the company. The easy equipment conversions these sub stitutes provide make the CFC phaseout
New UK rules on
genetically modified organisms New regulations governing the con tained use of genetically modified or ganisms (CMOS) came into force in Britain February 1. They are designed to provide adequate controls for any work conducted with such organisms,in con ditions intended to prevent their escape into the surrounding environment. Rules governing the deliberate re
and the types of organism used, in line with a prescribed system,carry out a risk assessment, and adopt controls,includ ing suitable containment measures. In addition, special plans must be drawn up to deal with any emergency, and the regulations insist that HSE be notified of any accidents involving GMOS.
New Industrial
Research Chair at U of O
lease of CMOS into the environment
will be covered by another set of rules planned to be set before parliament soon.
The University of Ottawa has launched
The latest regulations, based on wideranging consultations, implement a European Commission Directive. They
in membrane separation science and technology. Research conducted by the
a new $1.8 million dollar research chair
introduce for the first time in the UK a
British Gas/Consumers Gas/National
procedure through which consent must be sought for certain work with CMOS, as well as covering the human health and environmental protection aspects
Science and Engineering Research Council(NSERC)Industrial Research Chair in Membrane Separation Science and Technology will focus on the pro cesses surrounding the purification of natural gas. The chair's research may
of such activities.
The regulations stipulate that anyone intending to carry out GMO work must notify the Government's Health and Safety Executive (HSE) and, in certain cases classed as involving higher risks, wait for permission before beginning the work.They must classify operations.
much more feasible in the critical food
also lead to advances in environmental
cleanup technology such as water treat ment and purification. Following the inauguration ceremony a tour of the laboratories was led by chair-holder, Takeshi Matsuura.
ARTHUR TECHNOLOGY
ELECTRONIC LEVEL & FLOW TRANSMITTERS
supply industry.
Du Font's"Suva" HP refrigerants will minimize the cost for servicing existing systems because only limited changes are required in the conversion process. HFC-125 is targeted primarily foruse in new equipment.It also is under develop ment for use in sterilant gas applica
ON-LINE AND LABORATORY RESPIROMETERS MONITOR
tions.
In 1993, Du Pont will commercialize
"Suva" HP62, a non-ozone-depleting blend of HFC-143a, HFC-125 and
I
HFC-134a. The product's high energy efficiency makes it the option with the lowest total global warming potential. It will be targeted for new equipment in the same industries currently served by
Stability, Aeration, Nitrification, Return Siudge
R-502.
Du Pont has had "Suva" refrigerants commercially available since 1990 and has three commercial-scale plants operating. In addition to its "Suva" refrigerants, Du Pont has four other families of CFC
substitutes — "Formacel" foam expan sion agents, "Dymel" propellants, "Axarel"cleaning agents and "Solderel" no clean solder paste. The company has invested more than $400 million in the development and
SERIES 700
Toxiclty, BOD, Treatabillty
CONTROL
I
Submersible
berehole/probe level transmitters for deep wells or burled storage vessels. SERIES 310
... anti much more
Meosures level ond flow in
opplicotions using PARSHALl flumes ond weirs, such os sewoge, woste, or paper stock.
• Test microbial
respiration rates in undiiuted iiquid samples.
SERIES 200
• On-iine respirometer monitors up to three
Monitors liquid levels in tonks ond reservoirs
contoining
sources - even upstream
seowoter, oils,
in timed sequence.
or corrosive
moteriols. 3115 Halpern Street St. Laurent, PQ H4S 1P5
Pi©
Telephone:(514) 335-9071 FAX:(514) 335-9339
^uontime
^
PRESSURE SENSORS
(Canada) Inc.
3115 Halpern Street, St. Laurent, PQ H4S 1P5
Tel.:(514)335-3263 Fax:(514)335-9339
^
commercialization of CFC alternatives.
Circle reply card No. 236
Environmental Science & Engineering. March 1993
Circle reply card No. 237 15
A "Solution" for ZEBRA MUSSELS We are therefore focusing much of our technical expertise on this subject. We are consulting with experts to establish dosage levels and techniques best suited to help control the
The issue of zebra mussels
Is attracting Increasing attention from municipalities, utilities, government agencies and Industries around the Great Lakes.
spread of zebra mussels.
One solution Involves the use
of JAVEX-12™sodlum
hypochlorlte, which kills the
If you'd like to discuss this current problem, or be kept
zebra mussel larvae.
Informed of the latest
Information, please fill out tf
I" "nl/i'i
Yes, please keep me Informed on the use of JAVEX-12 sodium hypochlorlte for controlling zebra mussels. For current project □ For future project □ For research purposes □ Your name Title
Organization Address
d Postal Code
Phone; (
)
Mail to: Colgate-Palmolive Canada Inc. 255 WIcksteed Ave., Toronto. Ontario M4H 1G8 Phone: (416) 421-6000
Fax: (416) 425-9320
ore m
Envirofunenral Science & Engineering, March 1993
Water treatment
By Rod Holme*
Every drop counts — Canada's first national conference on water conservation
Every Drop Counts",Canada's
which was jointly developed by the Canadian Water and Wastewater Asso
First National Conference and Trade Show on Water Conservation was held in
ciation and the Rawson Academy, has Full Cost Pricing and Conservation as principal objectives, and makes use of marginal cost pricing theory. It is avail able exclusively through CWWA in
Winnipeg from February 4-6. Spon sored by Environment Canada under the Green Plan, the Conference in
cluded participation by a broad range of federal and provincial agencies and as sociations, including the Canadian Water
and
Wastewater
Ottawa.
The Water Audit Handbook is partly based on the audits undertaken last year at ten federal facilities, including the
Association,
which held its Annual Meeting in con junction with the Conference. Total attendance exceeded expec tations, with over 400 registrants rep resenting the public and private sectors across Canada, not to mention a strong international presence. Addressing the opening session, San
Centre Block of the Parliament Build
ings. This is available free from Envi ronment Canada, and outlines the
simple procedures that were used to identify significant potential savings at all the facilities that were studied.
dra Postel of the Worldwatch Institute introduced a theme that was to be heard
frequently throughout the Conference — paying thefull cost of water. She also commented on the fact that two thirds of
world water use is for agricultural pur poses. A modest reduction in this con sumption can make available signifi cant additional quantities for domestic
use, particularly in the developing world. A series of concurrent sessions over a
day and a halfcovered the role of Muni cipalities. Industry, Consumers and Agriculture in Water Conservation, prior to the delegates participating in 15 Workshops. These covered a detailed range of water conservation issues from education and training, to regulations, pricing, water audits, implementation and pollution prevention. The great value of these workshops was the opportunity to discuss ideas and experiences, since one of the main con clusions of the Conference was the ur
Rod Holme
overall water conservation awareness.It
Canada are too low!
Some of the strategies that need im provement involve replacement pro grams in municipalities, where low par ticipation can lead to small savings.The Region of Waterloo,Ontario, was one of the trade show exhibitors,covering their program to replace all fixtures in the homes of a designated group of volun teers, and to monitor electronically water consumption in these homes in comparison with a group where no changes were made.They are predicting reductions of 30% on this basis. Interes-
Have you thought of checking your water meter in the dead of night to see how much water your empty buiiding is using?
gent need for more effective informa tion transfer. There is an enormous
amount of duplication and re-inventing the wheel taking place. The proven suc cesses need to be more broadly com municated, and more importantly, the not so successful strategies need to be better understood.
Case studies presented at the Work shops demonstrated that water conser vation is real and achievable. Industry in particular was able to show very real savings with very fast paybacks, even with the recognition that water rates in
*Vice President,Water Supply,Proc tor & Redfern Limited and Chair, On tario Section,American Waterworks Association.
There is now a need to see the expand ing audit process translated into im plementation of projects, to actually achieve the savings, and to encourage is also interesting to note that the newly created Ontario Clean Water Agency has water conservation and demand man
agement as one of its mandates. It was also suggested at the Conference that the broad benefits and implications of water conservation — or efficiency as it is being called in some quarters — need to be better explained to a Canadian public who see vast quantities of fresh water all around them.
At the closing session of the Con ference,the Federal Minister ofthe Envi
ronment,Jean Charest, made three sug gestions to further the work at the Con ference. He commented that these sug gestions were practical, and able to be self financing through realistic pricing and the savings to be realized from re duced consumption. His suggestions were: • All sectors of the economy, private and public, should develop specific plans and programs to increase the
efficient use of water. tingly, many of the water audits under taken at industrial and government • Such plans and programs must pro pose clearly defined actions: that is. facilities over the last two years have pointed to minimum savings of the they must go beyond general goals and promises, so they can result in same magnitude. The Workshops also noted that water reductions that are measurable and can be wasted from some simple but tailored to the uses involved. long undetected causes. Water pipes • We must do a betterjob ofdisseminat flowing free to waste are more common ing information, avoiding duplica tion and enhancing co-operation. than any of us imagined. Have you thought of checking your water meter in Mr.Charest also made mention ofthe the dead of night to see how much water emphasis on realistic pricing and the your empty building is using? substantial benefits and short paybacks Two new publications were released for water conservation measures. There during the Conference. These were En appeared to be a consensus of those at vironment Canada's Municipal Water tending the Conference that economic and Wastewater Rate Manual, and their factors would be the driving force be
Water Audit Handbook. The Manual,
Environmental Science & Engineering. March 1993
hind the success of water conservation. 16A
Conference special
Spring Conference Previews • New Environmental Technologies
Papers on:
• StormCeptor — A High Energy Gra vity Separator • Landfill Design, Construction and Operation Methods • Egg Shaped Digester Technology • Pilot Scale Testing of Systems for Ter Comes to Canada tiary Treatment of Landfill Leachate • Floating Diffuser Aeration Systems for Energy Efficient Upgrades • Anaerobic Treatment of Sanitary • The ZenoGem™ Process for Oily Landfill Leachate • Landfill Issues
• Landfill Leachate and Odour Control
Using RBCs
The 22nd Annual Conference
• Legislation and Public Education • MOE Policy Towards Future Servic ing of Communities • MOL Guidelines for Applying Waste on Land
Pollution Control Association of Ontario
April 4-6
Regal Constellation Hotel 900 Dixon Road, Toronto 22 Years of Technical Environmental
Leadership Monday April 5, 1993 — Opening Plenary Session Panel Discussions
• Our Changing Environmental En gineering Field • Public Perception, the Media and the Environmental Agenda
AWMA Ontario Section
1993 Spring Conference Environmental Management: Issues and Emerging Technologies April 25-28, 1993 College Inn, Guelph, Ontario
• Methods of Introducing Public Edu cation Programs in The United
Wastewater Treatment
• On-Line Phosphorus Analyzer • Evaluation of the Feasibility of Bio logical Excess Phosphorus Removal in the Halton Region • Water Audits — The Potential for Re
ducing Water Consumption • Full-scale,Side-by-side Comparisons of In-waste Oj Transfer Efficiency — Fine & Coarse Bubble Diffusers
States
• Investigations of Phosphorus Re moval Involving Use of the ClariConservation:The Waterloo Approach Cone Technology Tuesday, April 6, 1993 — Papers on: • Current Trends in Meeting Ontario's • CSOs — Stormwater Management and Treatment Stringent Phosphorus Limit • Commissioning of An Automated • Combined Sewer Overflow Control
• How to Educate the Public in Water
Wastewater Treatment Plant — A
Case Study • Reducing Costs in Wastewater Treat ment Plants
in Ontario
• Demonstration of Advanced High Rate Treatment for CSO Control in Metro Toronto
• The issue of Total BOD, versus Car • The Longfield Davidson UV Treat ment Facility for Stormwater bonaceous BOD, as a Parameter for • The Role of Tunnels in solving the WPCP Effluent Limits CSO Problem • Sludge Accountability — The Key to Control of Biological Treatment Pro- Contact Sandy Pickett (416) 502-1440 Fax:(416) 502-1786.
• Exposure Modelling in Epidemiological Studies • Providing Information on Health and the Environment to Canadians
with Special Reference to Human Exposure
Air & Waste Management Association
Concurrent Session 2 Bio-Remediation
• Bioremediation of Contaminated Soils
Opening Plenary Session: Today's Envi ronmental Management Issues • Corporate Environmental manage ment in Light of Today's Legal and Commercial Pressures
• Due Diligence • From Command and Control to
"Voluntary Compliance • The Total Quality Environment Paradigm: A Strategy for Global Competition Concurrent Session 1
Human Exposure
• Epidemiology and landfill sites • Models to Predict Exposure at Con taminated Sites
• Exposure Assessments: Ambient and Indoor Air 16B
• Bioremediation: Where do we stand
today?
ONTARIO SECTION
• Bioremediation of Contaminated Sediments • Biosurfactants and Soil Reme diation
• Removal of Volatile Organics from Waste Air Streams
Advances in
Site Remediation Technologies • Overview of Site Remediation Issues
& Technologies
Concurrent Session 3 Advances in
• In-Situ Vacuum Extraction & Treat
Air Pollution Control Technologies
• Paper from Inco • Wet Limestone FGD System at
Ontario Hydro — Lambton TGS • The Design of a Dry Absorption System For Cleaning Gas From Municipal Waste Incinerators • The Petroleum Industry's Response to Control of Air Pollution
Concurrent Session 4
ment Technology • Solvent Extraction Technology For Oily Soils • Membrane & Perevaporation Tech nologies For Groundwater Treat ment
• Photochemical Destruction of Pol lutants in Contaminated Water: The Advanced Oxidation Process
cont'd on top of next page
Environmental Science & Engineering, March 1993
Conference special Solid Waste Management: Technologies and Issues • Interim Guide for Air Issues at Landfill Sites • Leachate Collection and Treatment
• State of the Art Incineration
Technologies Contact: Cindy Lasage (416)923-2918 Fax:(416)923-7521
lie education program Tuesday, April 20 • Efficiency & effectiveness — public • Conservation & Recycling expectations of performance • Municipal Water Treatment • Building public relations using the • Industrial Waste media • Operations Forum II and Student • Gaining the confidence of the pub Papers lic • Municipal Water • Skills development programs • Developments in privatization (inter national perspective) • Partners in tendering or selection
• Municipal Wastewater • Communication and Public Involvement
Wednesday, April 21 processes • Water audits — City of Toronto Technology Transfer Seminars Contact Astrid Tallon, (416) 252-7060. (choose one) Fax:(416) 252-3908. • Sludge Recycling • Water Conservation Strategies & Experiences British Columbia Water and Wastewater Association 21st Annual Conference
April 19-21, 1993 Coast Vernon Lodge
1993 Joint Annual Conference American Water Works
Vernon, B.C
Association, Ontario Section Ontario Municipal Water Association
Citadel Inn, Ottawa May 2-5, 1993
Contact Catherine Gibson
• Tel:(604)936-4982 • Fax:(604)931-3880
Reminder
Monday, April 19 • Municipal Water • Municipal Wastewater Treatment • Environmental Issues
Use the Reader Service
Card to get infonnation on products in this issue.
• Operations Forum I
Water — meeting today's realities through partnerships Topics include: • Treatment realities — quality and efficiency • The balancing act between disinfec tion by-products & microbial risks • Pilot plant study with Ottawa River water
• Plant rehabilitation vs new construc tion
• Composite correction program for water treatment facilities
• Distribution realities sustaining the infrastructure
• An integrated infrastructure manage ment plan — case study • Needs study experience • Partners in watermain rehabilitation
• Water quality and distribution system security for metropolitan Toronto • MNR — Water efficiency • OMWA political brief — municipal water works industry in the Province
BACKED BY 40 YEARS OF
EXPERIENCE,
direction
We understand; at NEO Valves, our recent expansion to offer a complete valve line for wastewater treatment projects is backed by 4 decades of steady growth in the supply of specialized valves.
WE'RE READY Recently we've earned further recognition in your FOR YOUR VALVES to the select group of manufacturers we represent. The next time you need valves for your project, we urge you BUSINESS to call us. Regardless of the requirement, you'll find that marketplace with the addition of RED VALVES and CLOW
we're knowledgeable, and responsive.
Now offering a complete line of valves engineered
. . . After all. we've spent the last 40years getting ready for your business.
for wastewater
of Ontario
• Employment equity — what does it mean to you? • User pay — full cost pricing • A federal and provincial perspective on TFIM guidelines • Bill 208 and safety audits • The plant inspection program of the MOE — its purpose and future
You didn't become a decision-maker in water
environment management overnight: you earned it through education and on the job growth.
applications
NEO VALVES 465 Norfinch Drive, Toronto Ontario MSN 1Y7
• The new "how to apply manuals" of the Approvals Branch — their origin, purpose and implementation • Water efficiency — designing a pubEnviwnmental Science & Engineering. March 1993
Tei:(416) 661-6G2G Fax:(416)661-6787
For more information, Circle reply card No. 159 16C
Canadian literature
ES&E included In The Dictionary of Canadian Quotations John Robert Colombo has come out
with a completely new collection of Ca nadian quotations; "thoroughly con temporary in its emphasis on the past few years, yet blending the modern with the eternal and the witty with the pro found." says the blurb. The Dictiouaty ofCanadian Quotations offers more than 6,000 quotations on some 900 subjects including some from Tom Davey. Some quotes are from his
they behave more like lovers — passion ately devoted, sincere in their love and highly suspicious of anyone whom they think might violate their beloved." Environmental Science & Engineering,
June-July 1990. "Environmental neglect is wide-spread across Canada, but no one does it with the elan and panache of La Belie Pro vince. Ignoring the constraints imposed
Dec. 1989.
by formal treatment processes,the Que-
"Government offices seldom operate at the vibrant pace of their counterparts in the private sector. Usually a languorous ambience pervades, as though bar biturates were being wafted through the
becois cleverly opted to harness the tur bulence of the St. Lawrence River in a
"The training of environmental engineers is no less rigorous than doctors or aero nautical technicians... Yet repeatedly en
Sewage (An art critic's view) "The strong WASP influence in Upper
spontaneous, free-form, high-volume, raw-sewage discharge mode. Inevitably, some critics carp about ineffectual treat ment; but all admit the Quebec effluent, like a good wine, retains its bouquet,that the effluent travels well, and that capital costs are negligible!" Environmental Science & Engineering June-July 1990 and also published in "AH
Canada ensured that waste treatment in
The Views Fit To Print"
vironmental decisions are based on the
Canada reached a high state of technical excellence. The final effluents though were rather sterile, lacking the variety, colour, and exuberance of a truly great artform.The resulting sludges are some what bland and generally lacking in bou quet. Pathogens too would appear not to travel well in the receiving waters. In fact the situation might be compared to the Bolshoi Ballet, where perfection of tech nique has been achieved at the expense of artistic spontaneity!" Environmental Science & Engineering,
book.^// The Views Fit To Print: others are
from regular ifScfeir editorials:
ducts like some Muzak."
invisible
chemical
Ail the Views Fit to Print(1985) Environmentalism
sayings — soothsayings might be a more appropriate word — of people with little formal training on the subjects." Environmental Science & Engineering, Nov. 1989.
"Then there's the ubiquitous spokesper son from Friends of the Earth and Energy Probe, and many other groups who seem to multiply like amoeba. Collec tively they produce more negatives than Eastman Kodak. I don't know why they call themselves friends of the Earth —
Engineering "Engineering still remains The invisible Profession — which, when it is not being ignored, is often scorned ... it must be really heartwarming being an engineer — getting blamed for environmental poli cies shaped by government lawyers — then taking the blame for environmental neglect across the country." Environmental Science & Engineering, Dec. 1989. Credit cards
CONTRACTING & TREATMENT EQUIPMENT REQUIREMENTS? CALL CAPITAL PETROLEUM SERVICES LTD.
As one of Canada's leading environmental contractors we otter an experienced statt to work with environmental en gineering firms implementing groundwater treatment,
plant decommissionings and soil remediation. Please add
"While you can buy virtually anything by credit card from symphony concerts to holidays in Spain, you need cash or a cheque up front to renew your driver's licence or auto licence plate. With the same credit card, you can of course order the most expensive meal, com plete with wine — in a town you have never visited before from a maitre d'
whose name you cannot pronounce. Credit cards enable you to buy AlkaSeltzer in Alberta, quiche in Quebec, suits in Saskatchewan and tires in Toron
us to your tender list! As Canadian dealers we otter the following remediation equipment.
• perox-pure™ U.V. enhanced oxidation
to — but you absolutely must pay cash to buy a five dollar bottle of plonk at a liquor store three blocks from your home in any province in Canada." Environmental Science & Engineering, Oct. 1988.
• Carbonair G.A.C. units
• Carbonair Air Strippers • Carbonair pre-engineered packages
Business
"Politicians, unfortunately, seem congenitally blind to the inevitability — even the desirability — of periodic industrial
Call us for your equipment needs! For references and information call:
ns ^hPET
cqpirqL PETROLEum SERVICES
LTD.
274 Enterprise St., Box 205, Vars, Ontario KOA 3H0 Tel:(613)443-1001 / Fax:(613)443-2205
fluctuations which let obsolescent tech
nologies wither, while encouraging vib rant new technologies to develop and prosper. In ecology it's called the bal ance of nature; in politics, it's called cor porate cruelty." AH the Views Fit to Print(1985) Stoddart Publishing Co. Limited 34 Lesmill Road, Toronto, Canada M3B 2T6 ISBN 0-7737-2515-6
For more information. Circle reply card No. 140 16D
Environmental Science & Engineering. March 1993
GORMAN-RUPP HAS THE WASTEWATER PUMPING SYSTEM TO FIT YOUR NEEDS Gorman-Rupp manufactures a complete line of pre-engineered, factory-built packaged lift stations. Whether it's a small or large wastewater collection system, we can provide an efficient, reliable pumping system including motors, controls, valves and piping ready for hook-up on site. Electronic Pressure Switch features dependable, solid-state construction and provides accurate, trouble-free monitoring of wet well liquid level. Bubbler Control design eliminates problems common to other bubbler systems. Controls are NEMA rated, UL/CSA Listed and will easily interface with users telemetry. Gorman-Rupp lift stations feature self-priming, solids-handling T-Series pumps specially designed for dependable wastewater handling. Mounted high and dry above the liquid being pumped with only the suction line in the sump,there's no need to disconnect the piping for servicing. A removable coverplate provides quick, easy access to the pump interior for removal of clogs or maintenance of components. And, no special tools are needed. T-Series pumps
I
Base-mounted "autostart" pump station with bubbler control and
standby engine automatically drives pump if power fails and eliminates need for expensive generator set.
are available in 3", 4",6",8" and 10" sizes with
capacities up to 3,200 gpm and heads to 130'. Rugged,economical fiberglass-reinforced enclosures house all equipment. They resist corrosion, mildew, mold and fungus and provide all-weather protection. Compact,low silhouettes and forest green colour blends in perfectly with surrounding landscaping. Enclosures provide easy access to interior equipment for
b
maintenance and service. Vandal-resistant
designs give added security. Ask us how we can help you with your next lift station project.
6' x6' above-ground lift station
features two 3" to 6" T-Serles pumps deliver ing 50-1,200 gpm on a single pump operation.
TM
For more information, Circle reply card No. 124
7' xlO' above-ground lift station features two 3" to 8" T-Series pumps with capacities from 50-2,100 gpm on a single pump operation.
GORMANRUPP Gorman-Rupp of Canada Ltd. 70 BurwellRd.,St. Thomas, Ont.N5P3R7 Phone:(519)631-2870 Fax:(519)631-4624 Telex: 064-73530 Distributors across Canada. Consult the Yellow Pages for your nearest Gorman-Rupp distributor. Environmental Science & Engineering, March 1993
17
By Jean Charest, P.O., M.P.
Guest comment
The value of water demands
realistic pricing mechanisms ince many of us pay so little for
S
water, we often don't think
about how much we consume.
But the underlying reality is
Indeed, in 1985 the Eederation of
Canadian Municipalities estimated a $7.5-billion shortfall in the money needed to repair and improve water sup-
that our water is a finite resource forever
being recycled, at an enormous cost. As one of millions of Canadians who make their home in the St. Lawrence
addressed. Under the Green Plan, we have made a
Basin, I have seen firsthand what hap pens when we take water for granted.
promising start, but there is still much to be done. And this is an issue needing action not by government alone but by all sectors of society. All of us use water daily, and all of us can and must help improve water quality and conserve
The St. Lawrence and the Great Lakes
constitute the largest freshwater reser voir in the world,but it is under strain as we draw on it to meet the demands of
unprecedented population growth and industrial activity. The same problems can be seen elsewhere in Canada â&#x20AC;&#x201D; for
example, in the Eraser River Basin in
M. Charest with ES&E's Penny Davey at the 1992 AQTE Congress.
The challenge Is to enhance our prosperity by using water resources, but without depleting or degrading them.
ply and sewer systems. If more Canadi ans were paying a price in line with the real costs of supplying their water, more money would be available to help cover these costs. More realistic prices would also reduce consumption and lessen the demand on our water treatment sys tems. helping to avoid expansion and investment in new systems. At home, we only see water when it flows between the tap and the drain. What we don't see is the process before and after this stage. To provide water at the turn of a tap. it must be drawn from the source,purified, and distributed. Af ter it goes down the drain, it must be cleaned again in a sewage treatment plant before it is returned to the original source. In order to ensure adequate treatment and good water quality, the price consumers pay should include the
vation. One of the most notable of these
entire cost of this circulation, from source back to source.
is Tom Davey, Publisher and Editor of
Yet today, many urban centres still
BC.
The challenge is to enhance our pros perity by using water resources, but without depleting or degrading them.
That is the aim of programs such as the St. Lawrence Action Plan, launched in
1988. It is also one of the main goals of Canada's Green Plan. As Minister of the Environment. I have worked to see that
goal achieved â&#x20AC;&#x201D; in particular, through the Great Lakes/St. Lawrence Pollution Prevention Plan and the Eraser River Action Plan.
I am pleased to see many other Cana dians doing their share for water conser-
Environmental Science & Engineering.
Through this magazine, Tom has worked diligently to draw attention to water treatment and distribution issues.
In recognition, on May 25. 1992. Envi ronment Canada awarded Tom his se cond Environmental Achievement Award,
in the category of Communications. The award goes to Canadian authors,jour nalists. film-makers and broadcasters
who have significantly raised public awareness of environmental issues.
In the magazine's first issue five years ago.Tom MacMillan.then Environment Minister, wrote an article on the water
pricing issue. He argued that Canadians undervalue their water resources and
that municipalities, which are respons ible for water pricing, had to bring prices into line with the cost of supplying the resource.
18
Eurther. our rate of consumption is growing. At the current pace, our use of water may double over the next 20 years. This increase will push the cost of pro viding the resource even higher,jeopar dizing the quantity and quality offuture supplies. "These imbalances must be
water resources.
In Eebruary Environment Canada hosted Canada's first national con ference and trade show on water conser
vation in Winnipeg. It brought together representatives of municipal govern ments. industry, and agriculture to ex change information on realistic water pricing, water conservation programs and technologies, water efficiency and consumer education. There was also a
trade show bringing equipment sup pliers and buyers together. Eor Canada to preserve its abundance of clean water for future generations we shall inevitably have to move toward more realistic water pricing.
Florida doubles water
consumption every 15 years Elorida's population has been doubling every 19 years since 1830 when record keeping began. "The current 13 million residents will
foster indiscriminate water consump have 4 million new neighbours by the tion by charging consumers too little. year 2000 plus 20 million more by 2050. Eor example. Montreal and substantial said Allen R. Overman, an agricultural engineer at the University of Elorida. portions of other large cities such as Overman projects Elorida. now the Toronto,'Vancouver, and Calgary use a nation's fourth largest state, will be run low. flat rate for unlimited use. At an ning neck-and-neck with the current average of 36 cents for every 1.000 litres population leader California sometime of water,Canadians pay less than halfof in the next century. what Europeans pay. California also has been doubling its Since many of us pay so little, we con population every 19 years, but the Gold sume enormous amounts â&#x20AC;&#x201D; an average en State is showing recent signs of a of 390 litres a day per person. And.only slowdown. Overman said. five per cent of this is actually used for Limited water supplies may be the drinking and cooking. The rest goes one thing standing in the way of a con down the drain, in showering, bathing, washing the dishes, doing laundry, and gested future in Elorida. Between 1950 and 1980, while population increased flushing the toilet. This consumption threefold, public water use and irrigation rate is high compared with the 200 litres increased eightfold. Since I960, public a day used in Britain and Sweden, and consumption of Elordia's water supply the 150 litres a day in Erance and has been doubling every 15 years. Germany. Environmental Science & Engineering, March 1993
Drip proof, gaoketed
Slam lock and removable handle.
drain channel.
Drain pipe elbow
f
Tamper proof
â&#x2013;
installed, ready
hardware.
for drain pipe
Simple to cast in place.
connection.
Continuous
Welding to CSA
piano hinges.
W47.2 All stainless
Certification
steel hardware.
Strong;
Gas springs for
withstands live
smooth and easy
load of 14 [\N per sg^uare meter and
operation. Flush design eliminates
tripping hazards.
also available H20
wheel loading for occasional traffic.
ust hatched Type "M" superior aluminum access hatches. Canadian designed and CsiY\ad\aY\ built
by MSLJ. install type "M" hatches where secure acceee is rec[uired in wells, cham bers, reservoirs, tanks and pumping stations. Single and double door stock sizes available, and MSU can also tailor build type "M" hatches to match the dimensions that you reiguire. Certified welding equality. MSU is certified by the Canadian Welding Bureau to CSA standard W47.2M-19S7 which provides for the certification of com panies engaged in the fabrication of aluminum and specifies the minimum reci_uirements which a company must meet and adhere to in order to obtain and maintain certification, detailed information available on reo|_uest including stock price list, specification details, material specifications and installation instructions.
MSU MISSISSAUGA LTD. 2222 South Sheridan Way, Mississauga, Ontario, Canada L5J 2M4 Voice: 416-823-4340 Fax: 416-823-4947 1-800-268-5336 For more information, Circle reply card No. 125
Environmental Science c6 Engineering. March 1993
19
Air pollution
Behind the smokescreen: the state of
Canada's air â&#x20AC;&#x201D; a Poilution Probe report borne organics or heavy metals. Large industrial sources,such as the kraft pulp mill in The Pas, and smelters in Flin
Flon and Thompson create significant local air quality problems. These two smelters also contribute 540.000 tonnes of SOt to eastern Canada's acid rain
problem annually. The Manitoba Mi
nistry of Environment spends some what over 2.2% of its total budget on air quality issues.
t
Ontario's large industrial base and large urbanized population conspire to pro duce a rich mix of air quality problems in the province; urban smog, airborne toxic chemicals, acid rain, and green house gas emissions. According to the Ontario Ministry of Environment. To ronto's air quality in 1989 was worse than that of Chicago, Atlanta or Boston.
Increasingly VOCs are being cited in air pollution articles. Photo shows a catalytic converter used in the UK which destroys volatile organic compounds at lower tem peratures than conventional direct incineration methods.
British Columbia is blessed with spec tacular geography, but air pollution threatens to obscure many beautiful views. The Lower Eraser Valley is often shrouded in smog,and many valleys in the interior of B.C. experience smoke pollution from large-scale burning of forestry and other wood wastes. Aging pulp mills are major sources of sulphur dioxide and hydrogen sulphide. To some extent, cities like Vancouver and
Victoria have made efforts to pick up the slack. The current efforts to develop a Clean Air Strategy for B.C. may indicate a shift in provincial priorities. The new vehicle emission and testing program in the Greater Vancouver Regional Dis trict is a very positive development, and should help cut ground-level ozone pol lution in that region. B.C. spends an estimated 10% of its environment bud
get on air issues. Alberta's air monitoring and public re porting services are of a far higher ca libre than those of British Columbia, Saskatchewan and Manitoba. However,
Canada's oil patch is also the nation's largest per capita emitter of carbon dioxide, and lacks any clear strategy or reduction targets for controlling green house gases. As a consequence of largescale energy production and refining activities, significant quantities of vola tile organic compounds are released in Alberta. Alberta is the third largest emit ter of sulphur dioxide after Ontario and Quebec. Sulphur dioxide emissions are actually on the increase, and are being
deposited in sensitive regions, largely 20
outside provincial boundaries. It re mains to be seen whether or not the
much-heralded new Clean Air Strategy for Alberta results in concrete improve ments with regard to these and other air quality concerns. Alberta spends 3% of its environment department budget on air quality management.
Saskatchewan has a small population base, and an abundance of wide open spaces. As a consequence, the province seems to enjoy fairly good air quality. Unfortunately, since air quality reports are published sporadically for only two cities (Regina and Saskatoon), it is im possible to say whether industrial emis sion sources such as steel mills and
power plants result in locally degraded air quality elsewhere in the province. Carbon monoxide levels in Regina have on occasion exceeded guidelines, but otherwise, residents of these two cities
are able to breathe reasonably clean air. Dust can be a problem in rural areas. The province is preparing a Clean Air Strategy,but it is not expected to be com pleted for at least another year. The Sas katchewan Ministry of Environment and Public Safety spends about 3% of its budget on air related issues. Manitoba's air quality also benefits from both a limited industrial base and
a windy, dry climate, which helps to dis perse pollutants.The Province conducts only limited air monitoring in a handful of communities, and its air quality re port is four years out of date. Virtually no monitoring is carried out for air
On the positive side. Ontario spends a larger percentage (9%) of its environ ment budget on air quality issues than most other provi nces. which makes pos sible a comprehensive air quality mon itoring program. An aggressive acid rain control program, launched in 1985, is
projected to cut SOj emissions by 60% by 1994. Ontario's regulatory frame work forstationary airpollution sources is weak and outdated. The province has no strategy in place to fight urban smog, and badly needs a car emissions testing program. While new garbage incinera tors have recently been banned in On tario, 100 biomedical waste incinerators
continue to operate, without pollution controls, says the Pollution Probe report.
Quebec has a strong manufacturing and industrial base, and as a consequence, experiences significant point-source air pollution problems, especially in sec tors such as aluminum production. Urban smog is also a serious problem, particularly along the St. Lawrence Val ley. Strong regulations on acid rain ha ve resulted in encouraging reductions in SOjemissions. A number oflarge waste incinerators operate in Quebec, and very large new incinerators are pro posed. Up-to-date public information on air quality is not easy to come by in Quebec: no annual air quality reports have been produced till now for the pro vince. However, the Montreal Urban
Community does publish a report each year on its local air quality. The provin cial environment ministry's ability to protect air quality has very likely been weakened by the closing down ofthe Air Resources branch in 1991. and the divi
sion of its responsibilities into several services. In the year 1990-91, Quebec
Environmental Science & Engineering, March 1993
Air pollution spent 1.2% of its environment ministry budget on air quality issues. New Brunswick is experiencing con siderable acidic deposition. Unfor tunately.the watersheds in much ofcen
Even so. the Department of Environ ment's allocation of one-half staff per son to cover all air issues (including public complaints) seems inadequate.
tral and southern New Brunswick are
have been able to operate in P.E.I, with out permits and without monitoring.
sensitive to acid rain, while those in southwestern New Brunswick are ex
tremely sensitive. While New Brunswick is now taking action to control domestic SO2 emissions, provincial programs on ground level ozone and global warming are still very hesitant, and not reassur ing. Ground level ozone is a problem during summer months in Saint John and surrounding areas. New Brunswick has relatively high per capita COjemis sion rates, due to a predominance of primary processing industries, a high reliance on electric resistance space heating,and until recently,the export of power to the U.S. Open burning of gar bage still occurs on a regular basis at roughly 200 small dump sites across the province. The province's most recent annual air quality report is three years out of date, and covers only the city of Saint John. New Brunswick's Environ
ment Ministry has 125 staff,of which six
To-date. industries and incinerators
Nova Scotia's air quality is clearly not a priority issue for the Nova Scotia gov ernment. An air quality report has not been published for the province since
to local sources,such as the Newfound
land Processing Refinery near Come By Chance, and the Corner Brook Pulp and Paper Mill. Yukon and Northwest Territories: the
arctic has traditionally been viewed by Canadians as a pristine environment; the source of the "clean, cold arctic air
masses" that so often sweep down on
the mid 1980"s. Acid rain seems to be of
our southern cities. However, research
little concern, despite the fact that numerous rivers in the province have lost their salmon populations. Incinera tion of garbage is officially encouraged through provincial capital grants, and at least one major incinerator operates without any pollution controls. Nova Scotia has moved quickly, however, to regulate the capture and recycling of CFCs from refrigeration systems. The province is also beginning to consider the issue of global warming, and has released a tentative draft global warm ing strategy. The Nova Scotia Deparment of Environment spends 2.5% of its operating budget on its air quality
ers have for some time been observing that arctic plants and animals bioaccumulate a wide range of chemical con
branch.
are devoted to air-related issues.
Prince Edward Island has a population base much smaller than that of many Canadian cities, and 60% of its popula tion is rural. This fact, and the prevail ing ocean breezes combine to provide most islanders with good quality air.
very small industrial base, serious air pollution problems seem to be restricted
Newfoundland devotes a mere one per cent of its Environment Department budget to air quality. This low priority is reflected in the absolutely minimal levels of air monitoring and public in formation. Because the province has a
taminants. such as cesium. DDT and
toxaphene. This is of particular con cern to northern peoples, whose tradi tional diet relies very heavily on game and fish. Most of these contaminants
have been transported by air and water from distant regions, where they are used in industry and agriculture. Since the break-up of the Soviet Union, countless horror stories have
come to light about appalling environ mental practices and conditions at faci lities all over the former U.S.S.R. Clean
up of these sites and updating of decrepit smokestack industries depends on massive infusions of international
aid. Until such funding is made avail able. the Canadian arctic will continue
to suffer from long-range air-borne transport of toxins. ES&E
Insertion Flowmeters Tools for every measurement task...
Utilities across Nortti America are striving to cut costs and eliminate unnecessary energy consumption. The Heath insertion Flowmeters provide leakage detection, hydraulic analysis and monitoring to help utilities run their systems and ongoing audits with the highest possible level of
efficiency. Flowmeters may be used to measure the velocity of both gases and liquids in pipelines.
The Heath Fiowmeter is inserted into a pipeline for measure ment or withdrawn for inspection without interruption to the line flow or reducing pressure when fitted with an isolation valve, its large operating ranges of up to 100 to 1 make the Heath Fiowmeter an easy, accurate and economical alternative to conventional metering methods.
.1
The Heath Mini Fiowmeter for smaller diameter pipelines or larger pipelines with restricted access and the Heath Waste Fiowmeter for measurement of potable water provide utilities with a complete range of Fiowmeter tools.
HEATH
i
Consuftants
... creative environmental solutions to liquid and energy losses.
2085 Piper Lane London, Ontario N5V 3S5
(519)659-1144 Fax:(519)453-2182
6923 Farreii Rd. S.E. Branch Offices: Montreal, RQ.(514)331-1580 Calgary, Alberta T2H 0T3 Saskatoon, Sask.(306)242-1713 (403)258-0151 Fax:(403)258-0577 Vancouver, B.C.(604)980-9552 Toronto, Ont.(416)464-9107
Pulp and paper regulations
Tough new regs for Ontario's Pulp and Paper Industry Environment Ontario has released a
comprehensive clean water regulation targeting a wide range of substances from Ontario's 26 pulp and paper mills, including organochlorines. Ontario's goal is for a zero discharge of organo chlorines by 2002. "We must safeguard health. More than 30 million people.6 million in On tario. depend on the Great Lakes for their drinking water. The Great Lakes can no longer sustain this kind of toxic
work together to ensure the environ mental and economic sustainability of our industry, our resources and our communities."
rine discharge for the eight kraft mills, measured by AOX*. is set at 1.5 kilo grams/tonne of pulp by Dec. 31. 1995 and at 0.8 kilogram/tonne of pulp by
All four categories of pulp and paper Dec. 31. 1999. In order to achieve the mills (kraft. sulphite/mechanical, cor goal of zero discharge of AOX by 2002. rugating. de-inking/board/fine papers/ the kraft mills must also submit AOX tissue) must meet the limits proposed in Elimination Plans to the government the regulation for all substances. Com under the following schedule: pared to 1990. a number of substances • initial AOX Elimination Plans to be will be reduced dramatically by 1995. produced 6 months after regulation including: is passed • chloroform. 96 per cent reduction overload." the MOL said when releas • interim plans by Dec. 31. 1995 and ing the regulation, Leb. 2. • phenol, 88 per cent reduction • final AOX Elimination Plans by Dec. In its 1992 report on the Great Lakes, • Biochemical Oxygen Demand 31. 1998. Copies of the Draft Effluent Limits the International Joint Commission (BOD).84 per cent reduction stated that organochlorines are "dan • toluene. 83 per cent reduction Regulationsfor the Pulp and Paper Sector gerous to the environment, deleterious The regulation includes limits that (PIES #2100) and supporting technical must be met by 1995 for the following materials including backgrounders and to the human condition,and can no lon ger be tolerated in the ecosystem, whe substances: Biochemical Oxygen De reports can be obtained by calling the ther or not unassailable scientific proof mand (BOD), total suspended solids, Ministry of the Environment's Public total phosphorus, chloroform, toluene, Information Centre at (416) 323-4321. of acute or chronic damage is univer sally accepted." phenol. 2.3.7,8-TCDD (dioxins) and Z3,7.8-TCDL(furans). Discharges from *AOX: Adsorbable Organic Halides, an The new environment minister Bud pulp and paper mills will also have to analytical method for measuring all orga Wildman said."We recognize the chal lenge this new regulation poses for our meet a stringent toxicity test; the waste- nochlorines collectively rather than In forest industry. We will be discussing waters must be safe enough for fish to dividually. Organochlorines are a family with them how to develop new technolo survive. of carbon-based compounds bound by In addition, the limit of organochlo- chlorine atoms. gies to meet those challenges. We must
New Low Cost SLUDGE DEWATERING System The DAB will dewater septage sludge to 20-28% dry solids, primary and secondary wastewater sludges 18-22% dry solids. When dewatering Incoming septage at 1 to 2 solids, COD, BOD, TSS, collforms, etc, removal rates are 93 to 99%, high
performance for this low cost and easy to operate,simple treatment system. The DAB system relies on the combined results of decantation and filtration using a patented membrane with collection pip ing to evacuate the water separated from sludge.
• Dally treatment volume per system up to 45,000 gallons. • Capital and operation costs low relative to the performance. • Technology developed In Sweden and transferred to North America.
• Several systems operating successfully, meeting objectives, available to visit.
• High organic matter and suspended solids no problem for DAB dewatering; plus the flexibility to dewater other sludges.
• Solids can be composted or chemically stabilized for Sludge In
beneficial use.
VALORACTION
inc.
C.P. 892, Sherbrooke ' Qc, Canada J1H 5L1 Tel: (819) 864-7942' Fax: (819) 864-7954 For more information, Circle reply card No. 122 22
Environmental Science & Engineering, March 1993
Environmental Monitoring and Compliance
As environmental regulations continue to tighten, Aquatic Sciences Inc.(ASI) has moved to develop the In-house technical staff and expertise to help Industry understand and comply with the new legislation. ASI offers a full range of effluent and environmental effects
monitoring. Working directly with our clients, we go beyond paper solution, giving extensive technical back-up to realistic and cost-effective programs.
I
Industrial/Municipal monitoring services Include: on-slte treatablilty studies for "end of pipe" compliance, primary device flow calibrations, analytical and toxiclty testing. In addition, extensive field resources allow
ASI to specialize In receiving water studies such as plume delineations, hydrology and bathymetry, assimilation capacity studies and sediment transport and deposition. Other related services Include benthic
surveys, In-situ bloassays and habitat resource Inventories. If you need more Information, please contact our Environmental Service Department.
AquaticSciencesInc. UNDERWATER AND ENVIRDNMENTAL SERVICES
45 Hannover Drive, Unit 1 P.O. Box 2205, Station B St. Catharines, Ontario Canada L2M 6P6
Tel. (416) 641-0941 Fax (416) 641-1825 For more information, Circle reply card No. 126 Environmental Science & Engineering. March 1993
23
U.S. Report
By Steve Davey
US FDA focusses on bottled waters
The US Food and Drug Administration has pro
posed tougher standards for bottled water along with new rules to ensure that the bottled product meets the same health standards as municipal water supplies.
FDA proposals will set uniform definitions for water des cribed as 'mineral",'spring",'distilled" and 'purified". In the US there is a general agreement that bottled waters are safe but a 1991 report by the General Accounting Office of the US Congress said the FDA would set tighter stan dards. FDA Commissioner David Kessler said: "We want to
ensure bottled water is labelled truthfully. Ifthe label says its mineral water, it should be mineral water. If it's from a
municipal source, the water should be so labelled." Established bottled water firms will probably welcome the proposals. In the US bottled water can be priced at up to 1.000 times the price of municipal tap water. In the US and Canada some consumer groups have argued there is some
This water vending machine customer spent $5 getting a week's supply for tiis family. ES&E photo
times little difference between certain bottled waters and
some tap supplies. But consumers have clearly voted with their cheque books in favour of bottled waters, now esti
Our own enquiries indicated the water charges in the area were significantly higher than those charged in the Greater
mated to be a S2 billion business in the United States
Toronto area.Certainly our own family water rates in Aurora are about half what the American family was spending on
alone.
FDA proposals will define mineral water as bottled water with at least 250 parts per million in total dissolved minerals. Additionally, it would have to originate from a protected groundwater source. Spring water would also have to origi nate from a protected underground source. Bottled water from municipal water supplies would have to be clearly labelled as such unless it was further processed so it could be designated as 'distilled" or 'purified" water. Bottled water which is not sterile and marketed for infants
must have this information on the label along with a state ment that the water should be used as directed,or according
vended water alone.
Toronto Environmental Tradeshow & Conference Exhibitors* 3M CANADA INC. ANACHEMIA SCIENCE ANACHEMIA SOLVENTS ARCTURUS B&W TECH.
BARRINGER LABS
to infant formula rules.
BEP TECH.
FDA will also require that bottled waters meet current federal standards for municipal tap water but lead levels allowed in bottled water will be lower than the tap water standard of 15 ppb. The new proposals do not cover carbonated,seltzers,soda or tonic water products which the FDA considers to be
BIG '0' INC. BIOMAN PRODUCTS CALGON CARBON CORP. CAMPBELL SCIENTIFIC CAN-ROSS ENV. CANADA INSTITUTE CANCOPPAS LIMITED CAPITAL PETROLEUM SERV. CARSWELL CENTRAL VERMONT PUB. SERV. CORP.
soft drinks.
Early reports did not mention drinking water vending machines where consumers fill up their own (US) gallon containers for 25 cents. These are almost as familiar as soft
drink machines at most Florida supermarkets. These machines are connected to the municipal supplies and. because of the benign climate are often installed out side the supermarkets with pop machines, giving 24 hour availability. Some are inside the buildings but the long store hours give consumers easy access to the vending ma chines. Some machines we saw had both reverse osmosis and
activated carbon, followed by UV as a disinfectant. These machines are extremely popular but — at 25 cents a US gallon — the cumulative costs make them expensive on a regular basis.
We questioned one man who spent $5 filling up large plas tic containers which he loaded up in his car. As he kept load ing the vending machine with quarters, he told us he did not like the taste of municipal water and estimated that he spent at least $250 each year on vended water for drinking
CHEM-KING
CHEM-STOR CLEMMER INDUSTRIES CONCORD RESOURCES CONVAULT CSE CANADA SOIL EXCHANGE DANATEC EDUCATION SERV.
DAVIDSON ENV. DELSAN GROUP EAGLE-PICHER ENVIR. SERV. ENVIROCLEAN LABS
HALOZONE RECYCLING HAROLD MARCUS HAZCO SERVICES IND. COMPLIANCE & SAFETY INDUSTRIAL ENV. SUPPLY
INDUSTRIAL PLASTIC FABS. INDUSTRY SCIENCE & TECH. JACQUES WHITFORD ENV. LAKEFIELD RESEARCH MANN TESTING LABS MEDISTOR METEX
MEY-CAN EQUIP. LTD. MILLGARD ENV. MOUNT ROYAL RECYCLING PCB CONSULTANTS PHILIP ENV.
PLASTICS CANADA QED ENV.SYSTEMS R & R DRILLING SUPPLY R&R CANDRUM RADIAN CANADA REPUBLIC ENV. REVERE-SETON ROCHESTER MIDLAND
SAFEWARE SCAND. AIR MEAS. SEALTEC COR. PROT. SOLMAX
ENVIRONMENT CANADA ENV. CONTAINMENT SYSTEMS ENV. SCIENCE & ENGINEERING MAGAZINE ENV. SYSTEMS CANADA EQUITY ENV.SERV.
SPHAG SORB
FOX ENV. COMPANY
VR SYSTEMS WALKER IND.
GOLDER ASSOCIATES GRUNDFOS CANADA GUNDLE LINING SYSTEMS
SPILKLEEN
SPILL TECH IND. SYSTEMS PLUS THE STATE GROUP THOMAS ENV. TROW
YORK FLUID CON. ZORBIT TECH.
See page 48 for further details
*asofFeb. 18. 1993
purposes. 24
Environmental Science & Engineering. March 1993
May 11 & May 12
Presenting The 7th Annual Toronto Environmental Conference
and Workshops and Tradeshow at The International Centre, Toronto
Environmental
Compliance
A% f p
'93 The new regulatory challenges The new management standards Presented by Environmental
Science &
Engineering Magazine
One-day conference -i- One day of workshops featuring an essential update on Canada's new generation of environmental management challenges and standards including:
%/ The new MISA regulations and
The new National Pollutant Release Inventory Canadian
Ontario's new incentives for pollution prevention
Environmental
Ontario's new waste reduction legislation
Regulation &
New CSA guidelines for environmental management
Compliance News
The New Standard for Environmental Auditing Chaired by
^ Spills reporting, response and clean-up requirements
Wiiims & Shier
Environmental Science & Engineering. March 1993
25
May 11th The 7th Annual Toronto Environmental Conference
All ' *1 y 9:00 to 9:40 John R. Willms Willnis & Shier
9:40 to 10:20 Bruce P. Powers Ani>us
Environmental
Environmental
Compliance '93 Ontario's environmental laws and regulations: A compliance overview • The EiivironmeiUal Protection Act(EPA)- A compliance overview • The new MiSA regulations • Ontario's new streamlined system of orders and approvals • Air pollution Inventory requirements • Hazardous waste regulations • Waste reduction regulations • Soil contamination • Liability of plant managers and workers • Trends in regulation, enforcement and penalties
The new National Pollutant Release Inventory: How to comply • The equivalent of SARA: Title III in the US, the new NPRI requires polluting companies to compile and maintain inventories. Are you prepared? Here's the steps you need to take now. How to sample and analyze air, solid & liquid wastes. How to keep and maintain records for NPRI compliance and for inhouse .source reduction, record keeping and due diligence. Using computerized databases. 10: 20 to 10:40 am • 20 minute coffee break
10:40 to 11:20 Terry Stopps Ontario Ministry of Environment and
Energy
11:20 to 12:00 William (Bill)
Glenn, Waste Reduction Consultant
Ontario's new Pollution Prevention Program: How to reap the rewards The trend in government policy is to encourage pollution prevention. The latest government initiative: The Pollution Prevention Pledge Program is now up and running. Find out about this innovative new program and how your organization can reap the rewards of going beyond compliance.
Ontario's New Waste Reduction law: A simple compliance program Ontario's New Waste Management Act 1992 (Bill 143) requires companies to compile waste and packaging audits and to initiate programs to reduce, reuse and recycle. This presentation provides a summary of your responsibilities under the act and provides a step-by-step guide to establishing and putting in place a simple compliance program.
12:00 to 2:00 pm. Luncheon Break. Visit trade show exhibit area. 2:00-2:40 Alan Knight Cdn. Standards
Association (CSA)
New Canadian Standards for Environmental Management • The Canadian Standards Association will, in 1993, be publishing its Guidelines for the 'Voluntary Implementation of Environment Management Systems. EMS is a set of internationally-accepted
principles that outline the fundamentals of Environmental Management.What are those fundamentals and how can they be applied to your organization?
2:40 - 3:20 Richard Harris KPMG Environmental
Services
Pulling together: The organization of an in-house environmental team Putting together an environmental management team to handle the many facets and functions of environmental compliance and liability. How should environmental responsibilities be distributed? What is the role of senior management? What is the role of outside consultants? What is the relationship between environmental management, occupational health and safety? How do you account for environmental costs and benefits'?
3:20 to 3:40 3:40 to 4:20 Ed Villeneuve Noranda Inc.
• 20 minute coffee break
A working environmental management system in practice • A policy/organizational structure • direct assistance to site and plant operations* environmental auditing • communications with employees at all levels • communicating regulatory information • reviewing capital expenditures • training and education in environmental matters • research.
4:20 to 5:00 Alex Keen Altech Ltd.
Practical steps to implement Environmental Management Systems Practical procedures to enable small and medium-size companies to implement the new Environmental Management Standard. • Gaining the support of senior management;• Environmental management planning; • Setting priorities; • Setting realistic budgets.
Registration form on page 28
Advance Notice .... May 12th .... One day only ... at:
The 7th Annual Toronto Environment Show
6 Essential 'Due Diligence' Workshops Choose from Track A,B, or 0
ENVIRONMENTAL AUDITING
SITE ASSESSMENTS & SITE REMEDIATION Practical Course
□
Canadian Standards Association
Introducing: The New Canadian Standard for
Environmental Auditing
The Canadian Standards Association (CSA) in cooperation with the Canadian Environmental Auditing Association (CEAA) will be launching the new Canadian Standard for environmental
auditing in May. This Standard is set to become the universally accepted benchmark for environmental auditing practitioners across Canada. This morning workshop session will be one of the first to introduce the standard to environmental
professionals and provide participants with a guide to how it will work and how it will affect your environment auditing activities. Essential for environmental managers and consultants
I A double workshop session led by Marc Trudei ot KPMG Environmental
I and John Payne ot HBT AGRA Site Assessment - A
Phased Approach
This intensive practical twin workshop provides a step-by-step guide to site assessment, decommissioning and remediation. The first part of the workshop provides an overview of the 3-phase approach to site assessment including: Phase 1- Visual inspections; Phase 2Sampling & Analysis in Environmental Investigations and Phase 3- Resolution & Remediation.
Remediation Action Plans,
Decommissioning & Clean up
Step-by-step guide to preparation and implementation of remedial action plans, current decommissioning and site remediation techniques and technologies. An essential workshop for all those dealing with actual or potential contaminated land
HAZARDOUS
MANAGEMENT,
MATERIALS AT WORK AND IN TRANSIT Two essential updates for superuisors S staff
RESPONSE, CLEAN-UP
The Complete Hands-on Course for all
The Comprehensiue and A workshop led by members of the
SPILLS:
transport S plant personnel
3 a workshop presented by leading
consultants in practical spills response and clean-up
Spills Management, Reporting & Response Legal requirements regarding spills reporting in federal and provincial jurisdictions. What is a spill? When should it be reported? Who should be notified? Spills in transit Preparation, planning and due diligence measures -Essential first emergency response training for drivers and operators. In-plant spills • Building the spills response team • health and safety considerations for first responders • Spills procedures • Emergency response preparedness • The role of SAC, CANUTEC • Practical demonstrations & evaluations of current
spills response technologies.
,
A double workshop session featuring Harry
^ I OussorenotTrow Consulting, David Hunter ot the law firm Aird & Berlis and Dr. Eric
Smith. President ot PCS Disposal Inc.
Clean-up of small-scale
oil & gasoline spills
• Applicable legislation • Who is liable? • A review of current clean-up technologies and approaches to the clean-up of smallscale oil and gasoline spills. Illustrated by three case histories featuring typical spill situations and how they were successfully responded to and remediated.
Clean-up of small-scale PCB spills
Low-level PCB contamination resulting from leaking transformers pose a special problem for those seeking to maintain compliance and implement cost-effective clean-up solutions. What are the allowable limits? Who should you contact for clean up advice? Yoin questions answered.
A popular annual workshop led by Jan Ghymlk, President CANWIT CONSULTING.
WHMIS - Update & Refresher - Including WHMIS II - It's the law!
Refresh your memory and those of your key supervisory staff! Keeping up to date with WHMIS symbols and requirements is not only necessary to keep your employees safe, it is also the bedrock of compliance. This popular WHMIS refresher workshop will give you the opportunity to make sure you know the WHMIS hazard symbols; the WHMIS labelling requirements, and have a full understanding of Material Safety Data Sheets. Also, find out what's new with
WHMIS II recommendations regarding hazardous wastes. Get all the details in a
presentation you and your staff can enjoy.
A hands-on workshop led byJan Ghymlk, President GANWIT
0
CONSULTING
Transportation of Dangerous Goods Update and refresher
Recent amendments to TOO Regulations require that "the person who is directed to handle, offer for transport or transport dangerous goods, be trained or work under the direct supervision or guidance of a trained person." The Regulations require that persons receive training every 36 months. Some retraining is required with each amendment schedule. Such a schedule was published in Cda. Gazelle Pt. /, Dec. 26th, 1992. This
refresher workshop will ensure you and your key supervisory staff have a good comprehension of new TDG classifications and safety marks, the documentation required for transporting dangerous goods, and the reporting of different occurrences. A MUST workshop for TDG workers, responders and those involved in supervisory roles.
Sponsored by: ENVIRONMENTAL SCIENCE & ENGINEERING
10 Fetch Or., Aurora, Ontario Canada L4G 5N7 Telephone (416) 727-4666 / Fax: (416) 841-7271
Environmental Science & Engineering, March 1993
Location: Toronto International Centre
27
How to register: To reserve your place at the 7th Annual Toronto Environmental Conference and Trade Show, phone our registration desk at (416)727-4666 and speak to Steve Davey, or fax (416)841-7271. Then mail the completed Registration Form (below), accompanied by payment(cheques payable to Environmental Science & Engineering Magazine.) to Environmental Science & Eneineerine, 10 Fetch Cr., Aurora. ON L4G 5N7.
May 11
May 12
May 11 +12
The registration for the one-day
To attend Conference
conference
The registration for your choice of one-day workshop sessions (choose from Track A,B, or 0 above) is just $295 per person. 1/2 day morning/afternoon workshop registration is $195 per
"Environmental
person
Compliance '93" on May 11 is just $295 per person.
plus Workshops (two days), total registration is just $395 per person. (You pay just $100 for the 2nd day of workshops)
Cancellations
Please note that refunds will be given for cancellations received in writing by April 21, 1993. We regret that refunds cannot be given after this time. Delegate substitution is permitted at all times. Please note, if you register for the seminar and do not attend, you are liable for the full registration fee, unless you cancel within the time period stated above. For further information
Should you have any questions or require assistance with registration, please phone the Registration Desk at (416)727-4666. N.B. Environmental Science & Engineering reserves the right to change the program content without further notice and assumes no liability for these changes.
7th Annual Toronto Environmental Conference and Workshops
Fax to: (416)841-/271
REGISTRATION FORM
(please photocopy this form for multiple registrations)
Mail to; Envitonmenlal
Science &
✓YES!
Please reserve a place for me and my colleagues at the 7th
Engineering
Annual Toronto Environmental Conference,Tradeshow and
10 Pelch Cr.
Workshops. I wish to attend:(Check one of the boxes below)
Aurora, ON L4G 5N7
□ Two days - Conference Plus Workshops in Track: (circle a, b or c). I enclose $395 (plus $27.65) GST)= $422.65 (cheques payable to Environmental Science & Engineering Magazine )
□ One day Conference (May 11) i enclose $295 (plus $20.65 gst) = $315.65 □ One day of Workshops (May 12) in Track a/ Track B/Track C (Please circle which workshop track you want to attend).Ienclose $295 (plus $20.65 GST) =$315.65 (cheques payable to Environmental Science & Engineering )
Q 1/2 day workshop only in Track a/ Track B/Track C (Please circle which workshop track you want to
attend and indicate whether you would like to attend the a.rn. or p.tn. workshop).Ienclose $195 (plus $13.65 GST) =$208.65 for 1/2 day registration (cheques payable to Environmental Science & Engineering Magazine ) ..Expiry:
□ I wish to pay for the above by VISA Account#..
Name:
Signature:..
Company/Org:.
Name:
NOTICE To ensure accuraie
regisiralion. please make
Job title:....
sure thai ihc label on the
registration rorm contains
Company:.
current and correci
information. Make any
changes necessary to the label. To register
Street:
City:
.Prov:
Code:.
additional names, please
photocopy this order form. Thank you.
28
Environmental Science & Engineering. March 1993
Sludge Management
*By Brian Evans
Biosolids disposal — an international overview of current and future trends
Theimplemcntalion and under-
slanding of biosolids (sludge) management and disposal has undergone significant changes in recent times. Up to the mid I98()s environmental professionals oversaw the ultimate selection of biosolids dis
posal options. Alternatives were clearly evaluated on the basis of technical
merit, environmental impact and cost effectiveness. The focus fell heavily on the technical considerations and there
was typically minimal review by the public and treatment plant staff. Times have changed dramatically. Professionals involved in wastewater treatment now march to the beat ofa dif
ferent drummer. Typically, environ mental interest groups decide early on which disposal options they will not ac cept. Then by selective lobbying with support from politicians and aggressive lesial advisors, they may be able to su
perimpose their preferred
disposal
method on the environmental assess
ment process. While the evaluation pro cess has to consider «// alternatives, in
creasingly these become superficial with the realization that the option favoured by the outside interests in the environmental process will probabh have to be implemented. Typical examples can be found in Metropolitan Toronto where the three large treatment plants have safely and effectively been disposing of solids by incineration for many years. Now there is a strong move afoot to convert these plants to composting. Similarly, on the liquid side, treatment proposals are be ing generated all across the heavily pop ulated Golden Horseshoe of Lake On tario for marshland treatment ofincom
ing sewage in place of the existing sewage treatment plants. While it is easy to criticize the marshland concept be-
FIGURE 1
BENEFICIAL USE OF BIOSOLIDS
cau.se of its ineffectiveness in cold tem
peratures. and the absurdity of turning Lake Ontario into one giant wetland, it is more difficult to argue against the beneficial use of biosolids. The current trend in wastewater treat
ment to optimization, reuse and benefi cial use of biosolids has changed the focus dramatically.The public and poli ticians are in complete support of the above initiatives because they not only reduce capital spending but also are seen to be environmentally friendly. Clearly as environmental professionals we have to adopt a new approach to the future of biosolids disposal. Approvals Issues The selection of any solids handling train is usually governed by the ultimate disposal options selected. Key con siderations in this step are: • Long term viability Does the proposed option provide a long term solution with long term dis posal sites or variable markets for the products or is it likely to be phased out as a result of stricter environmental
Form of sludge Agriculture and lartdscape planting
Processing
Dewatered sludge—i- (not processed-
Products
Use
-Dewatered sludge-Fertilizer
Drying
-Dried sludge
Composting-
-Compost —
Fertilizer
regulations in the future? • Can it be approved? increasingly this is a problem with incineration. Public resistance will
probably prevent introduction of any Fertilizer Soil conditioner
Wastewater
- Granulated ash
'— Incinerated a
sludge
Gardening soil
Construction
materials
,— Incinerated ash -
- (not processed]-
-Incinerated ash—i—Soil conditioning additive -Subbase course materials
-Subgrade materials -Aggregate of concrete — Asufaruto lira - Raw material of cement
I— Mudcap of reclamalion Granulation • burning Granulation ash
Melting • burning-
Light weight
-Burned-
goods
-Brick
-Permeability brick - Clay pipe Pressure forming- -Burned goods• burning —
Molten slag-
- Interlocking brick
-Molten slag
-Subbase course materials
Forming
-Formed slag —
-Tile - Decorations
TliicKened sludge -
Anaerobic digestion —Methane-
EElectric power generation Drive of blower Fuel
Dewa'ered sludge-
Multiple-effect evapolalion
So:id fuel -
Drying Incineration/Melting—Water heat-
- District air conditioning - Electric power generation
Reproduced from Design of Municipal Wastewater Treatment Plants, Vol. I and II. WEF Manual of Practice No. 8, ASCE Manual and Report on
Engineering Practices No. 76,1992.
w ith composting there is concern over odour production. • Sludge quality Will the faltering MISA (Municipal Industrial Strategy for Abatement) program result in a sufficient im provement of sludge quality to allow for continued beneficial uses of the
end product especially in large urban areas? If the high levels of heavy me tals and organics found in urban areas cannot be reiluced. will we be
forced to try and implement an al most unapprovable process such as incineration?
(rtot processed)—
Aggregate of concrets
^ Hneigy -
incineration in the near future while
• Viability of available markets Ifsludge management is privatized as is becoming increasingly common, will there be significant markets available at an appropriate price to Justify introducing the process or even privatization? • Storage requirements Most environmentally friendly dis
posal options require some form of winter storage. Will there be future *R.V. Anderson Associates Limited, Toronto. continued overleaf
Environmental Science & Engineering. March 1993
29
Sludge Management cont'd up in the ultimate solids disposal pro in philosophy will have a majoreffect cess. either in the form of ash or in on the quality of the solids because of sludge applied to land. The quality dressed then an ultimate disposal op the change in the RPS : WAS ratio. and quantityofthe.se solids will deter tion should be fairly easy to select. The impact of side streams is becom mine the feasibility of any disposal However, the ultimate option will be ing increasingly important. These option selected. heavily weighted towards options which side streams are generated from unit • Finally, a key process item which has can show beneficial use with minimal operations such as thermal con long been ignored but become essen capital outlay. Therefore the potential to ditioning. digestion and dewatering tial is the ubiquitous solids balance. privatize any option should receive high and provide a significant source of, An accurate and dynamic solids ba lance will provide operations staff TABLE 1 with an ongoing and immediate indi ESTIMATED MUNICIPAL SLUDGE PRODUCTION cation of the impacts of any process BY TREATMENT PLANT SIZE' change on solids handling and dis Percent Biosolids Produced posal. The increasing attention paid {dry tons/yr) Size (M USGPD) No. of Plants of Total to cost-effective operation will make tolerance oron-site storage?
Once these concerns have been ad
0-2.5
14,168
1,189,810
2.5-5
631
515,504
8
5-10
352
588,445
9
10-20
187
622,478
9
20-50
Emerging Technologies There are many new emerging tech nologies which will receive much con sideration in the future when evaluating
125
924,896
14
50-100
40
676,091
10
beneficial use alternatives of biosolids
100
41
2.324.274
34
15,544
6,843.493
disposal. • Animal feed production In this process irradiation is used to destroy pathogens and bacteria. This final product is relatively low in me tals (depending on the overall bio solids quality). Testing on animals found slight elevations in iron and lead in livers, but these were judged to be insignificant. • Biobrick production In this process, sludge solids sub stitute for sawdust and the tempera ture of brick production stabilizes the sludge. This idea has been around for over 100 years and has good potential
TOTAL
1.
this essential in the future.
17
Based upon analysis of data from the 1982 Needs Survey supplied by the U.S. EPA Sludge Task Force, 1983.
Reproduced from Activated Sludge Process Design and Control: Theory and Practice. Water Quality Management Library Volume 1. Technomic Publishing Company, Doncaster Penn. 1992.
priority. As has become evident from the pre vious discussion, the beneficial use of
biosolids should be the focus of any fu ture solids disposal philosophy. Figure I represents the most feasible beneficial use alternatives. Process Issues The nature of wastewater solids re
quiring disposal is affected by several in plant processes. These should be car efully considered before selecting an ul timate disposal option. • The ratioof raw primary sludge(RPS) to waste activated sludge (WAS). Ty pically the higher the ratio of RPS : WAS the easier the sludge is to handle with a greater propensity for energy recovery due to a higher volatile so lids content. However. RPS has signi
soluble BOD. Not only does this have the potential to overload aera tion systems, but has secondary im
pacts such as potential biofouling of fi ne pore diffusers. poor settling sludge in the final clarifiers and an increase in mixed liquid suspended solids.
in the future. The bricks look,feel and
The role of inorganic solids, largely ignored in the past, will play an in creasing role in the future. Inorganic solids basically remain in the treat ment process and with the exception ofa small quantity in theeffiuenl.end
smell like ordinary bricks and when tested with 15%-30% and 50% solids by volume,were found to be not as strong as the original but well within ASTM
ment.Traditional trends were to max
imize the process of handling raw sewage suspended solids in the solids handling train at the expense of the liquid train. Studies in Canada have indicated that the solids handling
mated to be equivalent to normal dis-
TABLE 2
ESTIMATED DISTRIBUTION OF MUNICIPAL SLUDGE
BY MANAGEMENT METHOD AND TREATMENT PLANT SIZE'
Percent of Sludge Managed by This Method by Plant Size Management Method
ficant drawbacks such as odour, a
health risk from pathogens and re quires many operational and health safeguards. • Direction of suspended solids treat
standards. However, costs are esti
Landspreading on food chain crops Landspreading on non-food chain
Large 10 mgd
Small
Medium
<1 mgd
1-10 mgd
31
22
10
12
8
17
11
12
18
Percent
of Total
crops
Distribution and marketing
11
13
19
Landfill
31
35
12
15
1
1
32
27
Incineration
Ocean disposal
Other, e.g., long-term lagooning TOTAL
1
0
4
4
17
12
12
12
100
100
100
100
costs on an annualized basis are
roughly equal to that ofthe liquid side
costs. Recent advances in process op timization and computerization have tilted the preferred process in favour of liquid side treatment. This change 30
1.
Based upon data supplied by the U.S. EPA Sludge Task Force, 1983.
Reproduced from Activated Sludge Process Design and Control: Theory and Practice. Water Quality Management Library Volume 1. Technomic Publishing Company, Doncaster Penn. 1992.
Environmental Science & Engineering, March 1993
posal costs.
Cement from sludge The sludge is flocculated sequentially with carbon dioxide and calcium di
Sludge liming This unique process called N Viro.
wastewater treatment capabilities. In
uses cement kiln dust to stabilize
422.000 dried tons of stabilized sludge produced 158.000 were disposed of by various means. Of this quantity 122.000 dried tons or almost 80% were disposed of by agricultural utilization and of the remaining 20% a significant portion
1981 it was estimated that of a total of
sludge, rendering it suitable for land application. The process is allied to the liming of sludge, but farmer resis
oxide at which point it is fed into a kiln. The resultant clinker is ground with gypsum to produce portland ce ment quality. This process has par ticularly good potential in Canada.
tance to the addition of excess lime
may have a negative effect. An important, truly Canadian solu-
went to landfill with a smallest fraction
going to incineration and sea disposal. Throughout the 1980s as more treat ment has been introduced,largely in the province of Quebec, this quantity has risen significantly. Currently the major developments in wastewater treatments are occurring on
TABLE 3
ANNUAL BIOSOLIDS DISPOSAL IN EUROPE
(1000 D.T. BIOSOLIDS/ANNUM) Agriculture
Landfill
Incinerator
Sea
Total
West Germany
698
1286
196
0
2180
France
234
446
170
0
850
Italy
270
440
90
0
800
both coasts with Vancouver consolidat
Netherlands
127
55
6
11
199
ing its sewage treatment and in Mari
Spain
173
28
0
79
280
England and Wales
507
151
66
234
958
Sweden
108
72
0
0
180
Switzerland
113
80
57
0
250
57
67
74
0
200
Austria Source:
time Canada communities such as Halifax. Saint John and Truro investi
gating advanced sewage treatment for the first time. Therefore the quantity of sludge produced per capita of sewered population is expected to rise through
WRC Survey of Engineer Sludge Treatment and Disposal Practices
out the 1990s. The trend will be towards
- 1984 data.
more beneficial uses ofend products via land utilization and composting.
Reproduced from Municipal Sludge Management: Processing, Utilization and Disposal. Water Quality Management Library, Volume 4. Technomic Publishing Company, Doncaster, Penn. 1992.
United States
Vermiculture
tion which has not been considered as
Long maligned as a way to treat sludge, the use of earthworms is gain ing significant popularity, largely be cause of their use in backyard composters. Sludge is fed to the earth
important to date, will become increas ingly popular in the future. This option
worms at 50% moisture and the cast
solution.
Canada
for the Highland Creek Treatment
remaining 70% on sewered communal
clear-out areas of forest. Not only does this option meet the requirements of beneficial use and being environment ally friendly, but it is also a practical
qualities, with a wide range of uses. Oil from sludge This process was originally devel
process is currently being designed
the US rely on septic systems with the
is the use of solids as fertilizer in the
ings are used as soil conditioner. The final product has excellent fertilizer
oped in Germany and has been fur ther developed at the Wastewater Technology Centre in Canada. The
The overall breakdown of biosolids utilization in the United States is similar to Canada. About 30% of the citizens in
systems. Table 1 indicates that while most of
the treatment plants are in the small category, the largest percentage of sludge produced is in the large plant category. Table 2 shows the breakdown of ultimate disposal options. As can be expected, the smaller plants have a pre
WORLDWIDE PERSPECTIVE
In the early 1980s Canada was. for its
ference for beneficial end uses whereas
size, one of the most well serviced coun tries in the world. Of the estimated 25 million Canadians. 74% lived in sew ered communities of which 37% were in
the larger concentrate more on incin
Plant in Toronto and is being evalu ated for the future Halifax Sewage
eration.
In the US 42% of the disposal can be classed as beneficial, by far the largest
TABLE 4 SLUDGE DISPOSAL AND UTILIZATION IN JAPAN
Treatment Plant in Nova Scotia. The Method of Disposal or Beneficial Use
dried sludge is heated to 30()°-350°C for 30 minutes in an oxygen free en
Sludge Type
vironment. The final volume of oil
Liquid
and char is less than the original. The oil produced is a Number 5 fuel oil meeting ASTM standards and is suit able for use in boilers and blast fur naces. It is estimated that two barrels
Landfill
Construction
Ocean
Works
Dumping 7.1
Dewatered
Composted Dried
334 10.5 8.0
Incinerated Ash
Metal Slag
of oil per dry tonne of sludge are pro
Total DS 1000 t/a
duced.
Total %
Aggregate production This process combines incineration
Agricultural and Landscaping
712
96
82.0
-
8.6
Other 195
11.5
54 3.9
0.5 32.0
3.2
110
8.0
14.5 789 6.2
3.4 157
%
437
19
50
7.3
3.8
0.4
6.1
2.8
1,117
2.9
46
Total
Dry Solids 1000 t/a
10.0
26.5
0.7
1.9
1.1 57.9 0.5
1,364 1X.0
1988 data
Reproduced from Municipal Sludge Management: Processing, Utilization and Disposal. Water Quality Management Library, Volume 4. Technomic Publishing
of dewatered sludge and municipal refuse in a rotary kiln.The ash is fused at approximately 1 100°C and is suit able for use as road aggregate. How
Ontario. 23% in Quebec and 9% in Bri
category, while incineration is next at
ever. due to the lack ofincineration of
tish Columbia and Alberta. These ratios
27% and landfill third at 15%. Ocean dis
municipal rei'use. this process has lit tle potential in Canada at the cur
will have changed somewhat in the 1980s as communities in Quebec and the coastal provinces improved their
da. the trend in the US will be to convert
rent time.
Company, Doncaster, Penn. 1992.
Environ mental Science & Engineering. March 1993
posal accounts for only 4%. As in Cana continued overleaf 31
Sludge Management cont'd the larger plants to more beneficial land uses, phasing out incineration. Europe With the Increasing trends towards globalization. Canadian attention will focus on what Is being done In the large industrialized regions ofthe world such as Western Europe and Japan. In Eu rope.the countries are a m 1 xture of hIghly industrialized and largely agricul tural. In Table 3. the typical disposal quantities in the various countries are
North America and will probably en counter the same fate in Europe. The Increased use of landfill is noted
increased beneficial use of wastewater
solids in recent years. This Is exem
plified by the reduction in the number of incinerators installed. After a rapid In
especially in countries where there are large populations living In sprawling
crease up to 1982 when 102 were In
urban areas. These countries such as
stalled. the trend continued to 1987 with
Germany. France. Italy, contribute a significant portion to the overall sludge qtiantity and are all noted to have great er landfill use than agricultural or in cineration use. However, in communi
a total of 149 being operational. How ever this began to slow to the current time when LSI were in place. Recently Japan has also started moving away from the standard Incineration option
ties which tend to be more agricultural
and tended to focus more toward alter
outlined.Tho.se listed account for96% of
or have a greater affinity with the sea.the
native beneficial uses.
all the sludge produced. The WRc sur
use of agricultural and sea disposal is
As can be seen In Table 4. ofthe total
vey related that there were .S.5 million
obvious. These countries include the
dry tonnes ofsludge for disposal In vari
Netherlands. Spain. England and Wales. In a recognizetl environmentally conscious country such as Sweden.60% ol the sludge is disposed of by agricul
of 1.364 tonnes of blosollds requiring disposal, incineration remains the most popular disposal method accounting for 58% of the total. Dewatering is se cond at 32%. Landfill remains the most
ture. whereas In smaller industrialized countries,such as Switzerland and Aus
common disposal destination account ing for 82%.followed bv laml utilization
tria. incineration plays a larger role. Japan
at"l2%.
ous ways.
• 37% was recycled to land Including agriculture, horticulture, land recla mation. forestry and parkland • 44% was disposed of at landfill sites • 9% was incinerated
• 7% was disposed of at sea • 3% was disposed of at other outlets including on-site at sewage works, la goons. stockpiling, sacrificial land, sludge farm, process products, and unrecorded outlets.
it can be seen ofthe major countries
producing sludge, that there are some significant differences between Canada and Europe. It should be noted that ocean dumping has been outlawed in
Japan has in recent years become
known as the most technically advan ced In environmental solutions and en
vironmental specialists tend to look to Japan for technical solutions. However, the country's overall environmental
record Is not as glamorous as portrayed and any Japanese solution will there fore be treated with some scepticism. The Japanese trend has been for an
SOLID & LIQUID WASTE ONE SYSTEM PROCESSES BOTH
25 Gal./hr.; 4 Tons/day: $98,000 US IDEAL FOR
• Remote Camps (Oil; Forestry; Mining) • Small towns with restricted budgets •
•
in central Canada will be towards Intro
ducing or converting to more environ mentally friendly options such as composting and land utilization. There will be an Increased awareness of new
emerging technologies which offer good future potential. Also It Is highly likely that the private industry will take an Increaslnginterest in privatizingbiosollds handling and disposal. In eastern and western Canada, many ofthe larger communities are receiving sewage treatment for the first time and other larger cities are looking to con solidate and improve their wastewater all these communities
more attention will be paid to options such as land disposal and landfill, de pending on which Is the most cost effec
Minimize hauling, landfilling, & risk Generate energy
tive. In eastern Canada, where landfill
space Is not as great a concern as in cen tral Canada, look for more use of land
fi ll disposal. In Western Canada, the
(heat, cooling, steam) •
The question that should be asketl at this juncture Is where will Canada be heading for the remainder of this de cade. Clearly, central Canada will have very little new development of wastewater treatment plants and hence solids disposal programs. The current trends
treatment. In
Hospitals and Industrial Parks
PAYS FOR ITSELF
•
Future Trends
large metropolitan areas will probably follow similar practices to Central Ca
Stabalise costs;
nada with the more rural areas favour
maintain control
ing land utilization.
In conclusion, look for major devel opments in biosolids disposal to occur
FEATURES
•
No operator req.
on the east and west coasts in the short
•
Handles all wastes
term and for a total revamping of the
•
Fits on trailer
ficial use of biosolids countrywide. The increased involvement of politicians and the general public in the decision making process will alter the role of the engineer to that of implementing a pre
current processes to include more bene
Ei^c^
EnEco Systems Inc. 2628 Granville St.
Van..B.C V6H 3H8
Tel:(604) 649-4518 32
Fax:(604) 224-3063
For more information, Circle reply card No. 120
ferred solution ratherthan recommend
ing one. ES&E
Eiiviroiinwnia! Science & Engineering. March 1993
Trace and ultra Trace Analysis... Polarography and Voltammetry made easy ■ Multimode electrode makes polarography routine ■ Software allows individual analysis of substance peaks
■
Memory cards store methods and data
■ Zoom function for post-analysis of curves Please check for
□ demonstration
□ literature
Name
Company
Dept.
Address
City
Prov.
Telephone
PC
Fax (area code)
^Metrohm
(area code)
BRINKMANN
OualHy products lor research and control.
NEW Automated Distiller
for NH3-H and other distillations • Pushbutton selection of distillation parameters • Safety shield Interlock • Acld/base-reslstant housing • Easy front access to all components for service/maintenance • Easy-to-read volume/time LED displays □ Call me to arrange a demonstration
Company
□ Please send literature
Dept.
Address
Citv
Prov.
Teleohone
Fax
P.O.
BUchi
BRINKMANN Ouality products for research and conlrol.
Select lon/pH Analysis... Automatic Multiple Standard Addition • GLP test for pH electrode function • Multi-point calibration with regression calculation
• Automatic multiple standard addition or subtraction techniques
• Storage of linear or non-linear calibration curves
□ Have a representative call □ Send literature only JiMefnihm CANPC 197B-2
BRINKMANN
Quality products foi research and c
User-friendly. iCW*k V «
In the complex world of piping, it's nice to hove user-friendly Victoulic® compo nents to rely on. With just a wrench and o little lubricant, it's the easiest system there is to
For more information, contact your Victaulic Distributor, or write Victaulic Company of Canada Limited, Rexdale, Ontario M9W 5N7. Or call 416-675-5575. FAX: 416-675-5729.
install.
The entire Victaulic system works the some way—couplings (like the patented rigid Zero-Flex® shown above), fittings, valves, flange adapters, reducers and more. Use Victaulic just once, and you'll discover there isn't a faster, easier, or more reliable way
iOtauliC
to connect pipe.
Best of all, you'll find the Victaulic system helps you save on total installed costs, as well
as future retrofit and expansions. We think that's as user-friendly as it gets.
Victaulic and Zero-Flex are registered trodemarks of Victaulic Compony of Canada Limited. ©1990 Victaulic. All rights reserved.
Environmental Science & Engineering. March 1993
For more information, Circle reply card No. 101
Health & Safety
staff training in Heaith and Safety is vitai under the Workers" Compensation Act. This includes providing first aid sta tions. each in the charge of an indivi dual trained in first aid by a recognized training agency. That individual's cer tificate of training must be promi nently displayed.
For companies whose staff work with hazardous waste in the USA. US law
requires that these staff people must complete the US OSHA 40-hour hazar dous waste course for Superfund(aban doned. badly contaminated) environ mental sites, as well as complete followup supervised work on one ofthese sites, plus complete annual 8-hour refresher courses. As well, supervisors at these sites must complete additional training. The handling of flammable liquids such as gasoline can be very dangerous if not conducted with proper work prac tices and equipment. It would be con sidered self evident due diligence that an employer of workers in Ontario who are handling such materials must en sure that those workers are approp
Sewer and water main projects can be hazardous without proper safety procedures.
Oneofthe key components of
an employer's Health and Safety Program is staff train ing. Or. starting from a dif ferent point of view, the most important type of training regarding liability ma nagement is often perceived to be train ing in health and safety. Staff training is provided with the intent to influence attitude and behaviour.
In my experience, health and safety training can be planned, developed and delivered most effectively if a few basicprinciples and approaches are kept in
for Industrial Establishments or for
It is a given that any work considered to require training of a particular group
Construction, whichever applies, under
of staff should also include the direct
and Safety Acts. As another example, workers respon sible for operating heavy vehicular machinery above ground in Ontario
supervisors of those staff members in the same training. A supervisor may claim to know all about the subject of the training. Even if that is so.it is wise for the supervisor to have experienced the
same person-to-person interactions and examples given, so they can be subse quently reinforced, directly with the work force.
In Canada, workers handling Con trolled Products in a manufacturing,
mind, as numbered below.
construction, mining,commercial, pro
First, an employer must be absolutely sure what training is mandated by law and.in a crunch, what is likely to be con sidered by a regulator or a court as clear evidence of due diligence, even if not explicitly required in law. Beyond these
fessional. or institutional workplace must be trained in the Workplace Ha zardous Materials Information System (WHMIS). Similarly, if workers are in volved in any hauling of Dangerous
minimum matters, there are a number
trained in the Transportation of Dan gerous Goods. This applies even when hauling from one workplace to another under the management of the same company, when that hauling occurs along a public thoroughfare,such as by truck, rail or water. Such training must contain information specific to those dangerous goods likely to be encoun tered by these workers. In Ontario, employers who pay pre miums into the workers compensation system have certain obligations speci fied by the First Aid Regulations made
of other matters which it is helpful to address in some form of staff training. Second, each type of training should
be planned for a defined target audi ence. Training time costs not only the expense of providing the expert trainer but also, in most cases, the expense of the time spent by trainees, usually dur ing business hours. Payroll overhead time costs may be particularly high for training of management and pro fessional staff. Costs may also include travel and accommodation. 34
riately trained. This would include training in the provisions of the Gas oline Handling Act and Code and the relevant provisions in the Regulations
Goods, then those workers must be
the provincial Occupational Health
should be aware of the requirements of the provincial Regulation for Roll Over Protective Structures. Similarly, the
Ontario Ministry of Labour Engineer ing Data Sheet on materials handling using Fork Lift Trucks requires exten sive training of truck operators. Such data sheets are treated as defacto regula tions by the Ministry in that they are used as the basis for Ministry orders.
Similar examples can be found in the other provinces and the territories. Third, the general goals and specific objectives of the training should be clearly written into the training plan, and clearly explained in the training itself. The training objectives should de fine who the minimum target groups should be. in order to meet the goals of fulfilling regulatory requirements of reasonable due diligence. Presentation of the objectives to those being trained helps them remain focussed on the main points (the forest) while they are dealing with details ofthe subject matter (the trees). Fourth, and much less important; specific, preferably quantifiable objec tives for training theoretically provide
Environmental Science & Engineering, March 1993
By David A. Whaley, Ph.D., R.O.H., C.I.H., D.I.H. the basis for evaluating the effectiveness of the training program. I put it in this very provisional way. because training gurus like to make it all sound cut and dried: that meeting specific, quantita tive objectives shows that the training was effective. In the real world it doesn't
often operate this way. Training in health and safety can bejudged effective if morale is good in the workforce and if. also, work-related accidents, hazardous
exposures and occupational illnesses are either prevented altogether or are significantly decreased since the train ing was introduced or upgraded. It is difficult to quantitate morale,but it is a very real phenomenon, having a large effect on absenteeism, work qua lity and output.(Obviously, work force morale does not depend only on the adequacy of health and safety training, but such training is a well advised com ponent of a conscious program to en hance work force morale.) As well, it is
particularly difficult to document the success of preventative training activi ties when no serious events have yet occurred and when success is defined as
the continuing absence of an adverse, unexpected event. Fifth,the above points emphasize that it is central to the success of a training program that top management is em phatically supportive. This support should be prominently displayed to all stakeholders in documents such as mis
sion statements, policies, company newsletters and the minutes of the Joint
Health and Safety Committee. What is needed is a management commitment
to effective training, not just the mini mum to demonstrate compliance or due diligence. If management understands both the importance of training and the great difficulty ofdocumenting its effec tiveness in preventing adverse out comes, a trainer can proceed. Without this support, roadblocks will have a
magical way of cropping up,just when the trainer thinks support has been achieved. This aspect may require some creative salesmanship. Sixth, an employer is very well ad vised to keep records of all stafftraining.
vocabulary the audience will understand: and use instructors who like people and have reasonably good "people skills". Ninth, the organization of the presen tation is important for effectiveness, in corporating selected repetition of main points for emphasis. The best way to present a topic is to start by summariz ing what you will cover, then explain with examples, then end by summariz ing what you have just said. Sometimes, necessary adjustments of schedule to accommodate questions
This should include, as a minimum,
make it difficult to follow all these
who attended(printed name plus signa ture), dates, outline of subject covered, where presented, who presented, as well as a separate file of the presenters' cre dentials and experience. All audiovisuals or printed materials used and
guidelines in a strict fashion,and,some
handed out should also be on file.
Seventh, the most effective training has two components,(1) a generic part, applying to a wide variety of situations and generally orienting those trained in the subject, and(2)specific material ap plicable to the workplace of the par ticular target audience. For example, WHMIS training should not only include universally ap plicable material on the relevant regu lations and the meanings of technical matters such as LDjqS or risk phrases, but also address the specific priority controlled products used at work by the particular target audience. Eighth, I would fivefundamental principles of training adults: Keep it simple; Tell the truth: Don't scare them; Use
times, the initial overview and final re
view get inserted into responses to ques tions. So,again,flexibility in presenting is important, but the general guideline remains valid.
Tenth,it is advisable to keep the num
ber of main points few, no more than three to four maximum,better only two.
It's fine to develop, explain and give examples, but the substantive content should be restricted to a few points at any one presentation event. From the point of view of providing effective training, it is important that the trainer ensure that management, who is res
ponsible for justifying the cost of train ing sessions, is clearly aware that effec tive training is spread out over time,into reasonable bite-sized pieces, that the memory can conveniently accept and retain. It is then up to the trainer, in developing his material,to plan for con tinuity, that is, developing a set of pre sentations which build on one another,
in sequence. Eleventh, the length of the training should be carefully planned to meet the goals and objectives identified. If dura tion of training is determined by other factors,such as cost or containment of a
confrontational labour relations pro blem, rather than actually enhancing the stated training goals or achieving objectives,then the training is less likely to be effective. In such cases,the money spent to deliver suboptimal training does not achieve the optimal "bang for the buck".Conversely,if the duration of training is tailored for the training need, to meet a broader operational objective, then it is possible for it to be effective.
For example, WHMIS training should be tailored to the complexity and scale ofthe workplace operation and the degree of possible hazard from use of the Controlled Products at that work
ES&E's editor at a Texas chemical plant which had strict safety precautions for workers and visitors.
Environmental Science & Engineering. March 1993
place. In my experience, for staff en gaged in construction or industrial operations, or engaged in environmen tal investigations or clean-ups, initial WHMIS training should last for a mi nimum of a half day and is better ad vised to be allocated one full day. 35
Health & Safety cont'd Twelfth, the frequency of training .ses sions reviewing the same or similar
minutes. For example, interrupt the talking every 30 to 45 minutes with a
material must also be tailored to the
demonstration, audio visual material,
specific workplace operations.This.too.
or questions, or some other form of au
would reflect the scale and complexity of the operation and the general anti cipated level of hazard as determined from the material safety data sheets, and.perhaps,consultation with a health and safety professional. At the moment, the frequency of ref resher training for WHMIS is not speci fied by law. though I understand this matter is under regulatory review. It is generally agreed by health and safety professionals that annual WHMIS ref reshers should be provided, which can be considerably shorter than the initial training, say about one hour. First aid training and training in transportation ofdangerous goods must be repeated every three years. For environmental workers likely to
dience participation.
work at hazardous waste sites in the US.
the annual 8 hour OSHA refresher
course is mandated by US law. Thirteenth. I strive to organize presen tations to break them up into sections,or "pieces", which get shorter as the train ing day progresses, to avoid overly tax ing the attention span. It is best if each piece of a presentation does not last more than 30 minutes, at the most 45
Fourteenth, instruction is far more ef
nuinely interested in their health, safety and morale at work. Within that context,
however, it is important to not let the questions take over your presentation time window. This requires judgement, flexibility and sensitivity to the audien
fective. if shared by two instructors, ra
ce's reactions.
ther than if presented by only one in structor. This is more expensive, but far more effective. Different voices and per sonalities are taking turns in the pieces ofthe presentation,and.ideally,feel free to interject a thought oftheir own during the other's presentation.This helps con siderably to maintain genuine atten
Judgement is required to prioritize each unexpected issue raised by ques tions. and allot answering time in accor dance with the goals of the training. Flexibility is required in that substan tial time spent on the questions may require clipping some time from other planned parts of the presentation. The presenter has to be able to make these prioritized adjustments on his feet.
tion.
Fifteenth. I prefer to operate infor mally. There are two good strategies to assist in informality: keep the groups small and encourage interruptions with questions. Training groups tend to be most effective if they do not exceed 15 to 20 persons at a time.
Sometimes, a question is an oblique way of bringing up a very real and criti cal health or safety concern. If the pre senter can be sensitive to identify the real concern and address it to the best of
his ability, given the work circumstan
I also try to encourage spontaneous, thoughtful questions throughout the
ces. he will have furthered one of the
presentation. This definitely helps keep audience attention. Scheduling of the presentation should allow time for such questions.The flip side ofthis approach is that it can lead to delays in the sche dule. if not carefully managed. It is im portant that the presenter be perceived as a friend of those being trained, ge
worker morale.
main
training
goals, to
enhance
Sixteenth, a matter already alluded to above is that I try to intersperse oral pre sentation time with audio-visual mate
rials and participatory activities. You can use samples of materials or small continued overleaf
THd\ADAPTABLE,ECONOMICAL ALTERNATIVEFOR LIQUID STORAGE AND HANDLING SCAT(Secondarily Contained Above-Ground Tank)system is a safe alternative to drums and other portable containers for storage and/or dispensing of petroleum products, waste oils, chemicals and other liquids. SCAT, UL-142 Listed, has a bulk storage tank, fully enclosed by a welded roof and containment reservoir to protect the contents from rain water and airborne contaminants.
storage/Collection Tank
Portable Fuel Station
With capacities from 270 to 20,000 gallons, SCAT delivers cost-effective performance for any size operation.
U.S. Patent No. 5,088,530
llipYj
y\yji)
Canadian Patent Pending
For complete information, write or caii today: industrial Environmental Supply, Inc. P.O. Box 36210
Greensboro, NC 27416-6210 800-768-4817
(919)274-4817
Ši99i ies, inc
For more information, Circle reply card No. 106 36
Environmental Science
Engineering, March 1993
Engineered water and wastewater treatment
equipment FMC provides practical solutions to your equip ment needs with one of the most complete lines of water and wastewater treatment equipment available. Our product design and development Is the result of over 70 years experience with installations across North America and around the world.
The FMC equipment line includes: screw pumps, bar screens, travelling water screens, grit collec tors, rectangular sludge collectors, travelling bridge collectors, circular sludge collectors, thickeners, aerators, air diffusers, flocculation
equipment, rotary distributors and auxiliary equipment. You can rely on FMC to meet your equipment requirements. Consult with us. FMC of Canada Limited, Material Flandling Operation, 650 Hood Road, Markham Ontario L3R 4S7
(416) 474-7500 FAX (416) 474-7542
-FMC For more information, Circle reply card No. 102
ISCO) the world leader in
Water Monitoring Instrumentation. Automatic Wastewater Samplers • Portable
• Refrigerated • Sequential • Composite • Flow-through
i>.
Health & Safety cont'd equipment from the workplace or of a source material from nature, such as a piece of ore containing asbestos. Ideally, these objects are small enough to be handled. If the ma terials are toxic, make sure the containers are secure, but transparent.
For sensory experience of less portable or more complex topics, a presenter can intersperse spoken material with flip charts, wall charts, projection slides, overhead projections, videos, or audio recordings. But never dependon the visuals to do aiiyour training work. Nothing is more deadly than a long ses sion restricted to passive viewing, even if well produced. Vi deos can be very compact, that is. package a lot of information into a short time effectively, and very vivid (more easily remem bered). But there is no substitute for direct verbal interaction
between an instructor and the persons being trained. I know of one company which has marketed interactive video for WHMIS training. Such interactive video might be useless for initial group training in WHMIS, but can be quite useful, if made available to staff over a period of time, to be used by individuals during work breaks, say 15-20 minutes at a time. As such, interactive video can serve as a comprehen sive review and reinforcement. If an employer is going to invest in leasing or purchasing such equipment, he should also create incentives for staff to spend their work break time in this way. Properly used, this could be an adequate sub stitute for an annual review.
1n
For more information, Circle reply card No. 117
Seventeenth, where training is mandated by law or con sidered a requisite of due diligence, it is important to issue to the staff who participated some evidence of attendance. This can take the form of a certificate, which can be displayed on the office wall; however,I find a wallet card generally more
Open ChannelFlow Meters
useful for staff. The certificate or wallet card should indicate
• Ultrasonic
• Submerged Probe • Bubbler • Variable Gate • Flow Transmitters
For more information, Circle reply card No. 118
For sales and service information contact:
Nortech Control Equipment,Inc. 135-4 The West Mall
Etobicoke, ON M9C 1C2 Phone:(800) 263-3427
the type of training, date of training and be signed by the trainer. It may include the name of the company paying for the training. Eighteenth, it is a good idea to encourage (or require) attenders to fill out evaluation questionnaires, to be filled out anonymously, which must be submitted, in order to
receive a certificate or wallet card indicating attendance. This can provide very valuable feedback, to better hone and adapt future presentations, so they will better suit the needs of the staff. Nineteenth,Ihave not dealt here in detail with the content
of health and safety training because it will vary widely among different types of work operations. The overall goals
of the training program are to enhance a realistic sense of security among workers, and thereby enhance morale. In general, the first specific goal of health and safety train
ing is to identify potential hazards, whether they be ex posure hazards from chemical, physical or biological agents, or safety hazards. The second specific goal of health and safety training is to train workers in the choice, limita
tions, use and care of protective equipment, particularly pro tective fabrics and respirators. The third major goal is to
identify the safe practices by which to conduct work, and clearly indicate, also, what practices are unsafe. It can be
helpful to develop written work procedures, or even a pro
cedures manual.
Notice that the mode of presentation in verbal training and a written presentation, such as this one. are very dif
(416) 622-7820 fax:(416) 622-6776
ferent. For example,Ihave presented here 19 points of guid
ance. This would be far too much for a verbal presentation. In written communications, there are also rules for effective communication which writers are well advised to follow. For more information. Circle reply card No. 107
■SCO
Quality products for monitoring the world's water 38
However, you have the advantage, as a writer, that your reader can stop in the middle, and take up again, once ref reshed. Also, the reader can readily come back to the earlier text to check on something that may not have sunk in. For several reasons, a written communication can hold a greater amount of substantive material than a verbal one. ES&E For more information. Circle reply card No. 250
R&D News
Supplied by the Canadian Association on Water Pollution Research & Control
Modelling the Activated Sludge Process
dioxide. Other methods of generating hydroxyl radicals and other oxidants,as
In a paper accepted for publication in fVarer Research, Laval University scien
well as other methods of oxidation that
tist P. Lessard and a U.K.colleague pre
water treatment, are also discussed in
sent the results for the evaluation of a model for carbonaceous and nit
this review.
have been suggested for organic waste-
rogenous substrate removal with refer ence to a comprehensive set of data ob tained from a 10-day monitoring study at the Norwich Sewage Works in eastern England. Substrate removal and the production, thickening, and recycle of biomass (suspended solids) were well replicated by the model. Sensitivity tests with the model suggest that recycled flows from a sludge consolidation tank were a significant factor in the longer
Precipitation of Phenols from Wastewater
Bacterial Leaching of Metals from Sludge
In a paper presented at the 8th Eastern Regional CAWPRC Conference,McGill University's J.A. Nicell described the work undertaken by himself and Uni versity of Windsor scientists J.K. Bewtra and K.E.Taylor on the development of a process for the polymerization and pre cipitation of phenols from wastewater by horseradish peroxidase enzyme. Batch and semi-batch experiments re vealed that the catalytic lifetime of the enzyme may be extended by maintain ing a low instantaneous enzyme con
INRS-Eau scientists D. Couillard and
centration in the reaction mixture. The
G. Mercier studied the biological solubilization of metals from anaerobically digested sewage sludge in a con tinuously stirred tank reactor using Thiobacillusferrooxidans. As described in a paper accepted for publication in Water Research, a minimal mean hydraulic re
instantaneous enzyme concentration was shown to be an important para meter in the design of a waste treatment
lAWPRC
term maintenance of aerator biomass concentration.
Oxidative Destruction of Organics in Wastewater National Water Research Institute sci
entist J.H. Carey has published a review of various processes that have been sug gested for the oxidation of organic com pounds in wastewater. As described in the Water Pollution Research Journal of Canada,the most widely applicable pro cesses are based on the generation of hydroxyl radicals by the photolysis of hydrogen peroxide,ozone and titanium
The leached sludge was more easily dewatered than untreated sludge. No sig nificant changes were observed in the total nitrogen and phosphorus content of the sludge which was a better quality product for agricultural use.
system. The process results in a con tinuous stirred tank reactor configura tion were also described.
sidence time of 18 hours resulted in the
Quality Assurance for Dioxin Analysis
solubilization of52% of the copper,62% of the zinc, and 78% of the manganese.
Environment Canada has issued a re
port on the internal quality assurance continued overleaf
Echotel® III Ultra n Two-Wire
Loop Powered Intrinsically Safe Non-Contet Level Transmitter
one msu transportable safety fiandle secures a multitude of fioles
► Microprocessor-based electronics allow user selection of range, span, transmitter or single point switch modes.
► Dedicated Echo Loss and Fault LEDs.
safe!handle
► Self-Test.
► Adjustable span from 12-228 Inches. For a FREE Brochure,
MSU MISSISSAUGA LTD.
2222 South Sheridan Way, Mississauga Ontario L5J 2M4
For complete information 1-800-268-5336 Fax:416-823-4947
Call: 416-678-2720 or Fax: 416-678-7407
^ Magnetrol^ Mississauga, Ontario, Canada
REGISTERED ISO 9001 • 2299.1
For more information, Circle reply card No. 111
For more information, Circle reply card No. 112 39
R&D News requirements for the analysis of dioxins in environmental samples. Developed by the Dioxin Quality Assurance Ad visory Committee, the report outlines those elements of a laboratory quality assurance program that are considered essential to ensure the reliability of dio xin data. Performance criteria by which data can be assessed are also estab
lished in this report. By focusing on principles and performance rather than procedural details, laboratories have the flexibility to follow specific sample processing procedures of their own choosing, and the need to develop re ference methods for individual environ
mental matrices is simplified or elimi nated.
Sediment Contamination In the St. Lawrence River Sediment data collected in Lac SaintLouis and Lac Saint-Pierre were ana
lyzed to determine the volumes and dis tribution of modern sediments and to estimate the volume of contaminated
.sediment. The estimates published by N.A. Rukavina and R.J. Delorme in a National Water Research Institute re
port are only preliminary but represent the first values for contaminated sedi
ment volume developed from a large
FINALLY,ENVIRONMENTAL PROTECTION SYSTEMS
and consistent data set. Results will be
useful as a model for incorporating exist ing chemical data to permit the calcula tion of contaminant levels, and as a
structure for planning future contami nant surveys.
Natural Degradation of Kraft Bleachery Effluent
Changes occurring in the pH-stable fraction of the high molecular weight (HMW)fraction of combined C- and E-
stage bleachery effluent from hardwood and softwood kraft mills were followed
by L. Roy-Arcand and F. Archibald over a 16-week period. As described at the 8th Eastern Regional CAWPRC Con ference. the HMW adsorbable organic halogen(AOX)showed substantial and continuing mineralization by both day light-dependent and daylight-indepen dent mechanisms. The results of this
THAT ARE COST EFFECTIVE
Pulp and Paper Research Institute of Canada study suggest that HMW kraft bleachery AOX degrades abiotically to release chloride over a relatively short time span under conditions similar to those typical of many receiving waters. Dynamic Model of the Anaerobic Wastewater Process
In a paper published in Wciut Science and Technology^ R.M. Jones and col leagues from the Wastewater Technol ogy Centre and McMaster University, present the results from a dynamic modelling study conducted on a pilot scale anaerobic fluidized bed. A model
structure was postulated based on the results observed in the dynamic expe riments. An extended Kalman filter
state estimation algorithm,employed to provide estimates of unmeasured pro cess states and parameters, improved the performance of the model, helped locate model inadequacies, and pro PALLETTANK BASIN WITH STEEL STAND
DOUBLE WALL STORAGE CONTAINMENT SYSTEM
• Portable, Lightweight, Minimum Space required • Made from chemical-resistant polyethylene • Other sizes available upon request
vided
information to direct further
model development. Phosphorus Transport in Agricultural Runoff H. Ng. J. Marsaiek and T. Mayer have undertaken a study on the Nissouri Creek agricultural watershed to deter
mine the temporal variation in phosophorus and to assess the role of sedi ments in transporting phosphorus in agricultural runoff. These National Water
Research
Institute
scientists
found that somewhat more than halfthe
phosphorus runoff was associated with sediment particles while the remainder
to\ y4to -A/mtann OFCANADA LTD. 794 McKay Road, Pickering, Ontario L1W 2Y4 Tel:(416)683-8222 Fax:(416)683-2969 Toronto Line:(416)798-7686
Leaders in engineering and technoiogy in container systems Manufacturers Reps required for Western Canada 40
For more information, Circle reply card No. 113
was in soluble form. Concentrations of
total and soluble phosphorus were higher by an order of magnitude in the spring and fall than in summer. Higher proportions of particulate phosphorus were observed during the early phases of runoff.
continued overleaf
Environmental Science & Engineering, March 1993
CLEANSE
THE SELF-CLEANING STATION ■ Significantly cuts your operation and
The first pump's startlevel is reached, and
maintenance costs
■ Automatic, trouble-free pumping
the duty pump then starts automatically. The flush valve opens
■ Cleaner station environment
for about 30 seconds,
■ Easy installation in new or old stations
stirring the sump water and resuspending any
■ Reduces inspections
settled solids.
MACTEC® control to govern starts, stops and alarms,
|—^
for storing data, and helping j In system diagnosis.
1/
s
j
-
When the pump's preset stop-level Is reached, the pump stops and the valve opens automatically, ready for the next cycle.
!
\
For further Information on Auto-Cleanse™ or any other Flygt system or pump, contact your Flygt technical representative today.
Good Ideas Take Flygt.
New 4901
non-electrlcal flush valve for automatic
1
Flygt
NEVAGLOG®
impeller for clog-free
sludge prevention
sewage
and removal.
pumping.
ITT Fluid Technology Corporation ITT Flygt, 300 Labrosse Ave., Pointe-Claire, P.O. H9R 4V5 (514)695-0100 FAX:(514) 697-0602 Vancouver ■ Calgary ■ Edmonton ■ Saskatoon ■ Winnipeg ■ Hamilton ■ Etobicoke ■
Sudbury ■ Ottawa ■ Polnte-Claire ■ Quebec ■ Val d'Or ■ Moncton ■ Halifax ■ St. John's (Nfld.)
For more information, Circie repiy card No. 103
R&D News Reduction of Trihalomethane
tests conducted on a surface water sup
mented incidents of livestock and wild
Formation Potentiai
ply for a community in northeastern
life poisoning attributed to cyanobacterial toxins. In a paper published in Water Science and Technology. S.L. Kenefick and colleagues from the University
The UVOX process, developed to re duce the high concentrations of trihaiomethanes resulting from chlorine disinfection of surface waters, has been
described by C.R.E. Jansson. Jansson Consulting Services, in a paper pub lished in the Water Pollution Research
Journal ofCanada.The process involves irradiating the water supply with ultra violet light in air-cooled units to pro duce hydroxyl radicals from the photo lysis of hydrogen peroxide. Pilot plant
Saskatchewan were successful in reduc
ing trihalomethane formation potential to very low levels. The process also slightly enhanced the ability of ultra violet light to inactivate Giardia cysts. Contamination of Prairie Drinking Water Sources
Algal blooms in eutrophic lakes have been regarded by some as primarily an aesthetic nuisance for recreational and
drinking water uses despite well docu-
of Alberta and the Saskatchewan Re
search Council describe the results of a
survey conducted on three eutrophic water supply lakes and eight rural dug outs experiencing cyanobacterial blooms. Atnong other things,the results showed that cyanobacterial odourcausing compounds in water did not provide reliable warningofthe presence of the hepatotoxin microcystin LR in these cyanobacterial blooms. Determination of Chiorobenzenes and Hexachiorobutadiene in Sediments
Ordering
Existing methods to extract chioroben zenes and hexachiorobutadiene in sedi
the most
ment samples are time consuming and produce large quantities of waste sol
up-to-date
vents. National Water Research Insti tute scientists H.B. Lee and T. Peart to
gether with R. Hong-You. Wastewater Technology Centre, have developed an improved method using supercritical fluid extraction in place ofconventional
information in the world
solvents. The method is both cost effi
cient and environmentally friendly. Under optimized conditions,the extrac tion time is only 25 minutes and recover ies range between 75 and 85 percent.
is as easy as ordering
Residual Chlorine Decay G.D. Milne. S.J. Stanley and D.W. Smith conducted field investigations of the mixing and decay of discharge plumes containing 2.0 mg/1 of total re sidual chlorine(TRC)in the North Sas
this.
katchewan River downstream from two
water treatment plants in the City of Edmonton. As described by these Uni versity of Alberta scientists in a paper accepted for publication in Water Re search.environmental concentrations of
CISTI IS THE FASTEST WAY to find the most up-to-date scientific, technical, and medical information in the world.
A service of the National Research Council, CISTI helps Canadian engineers and scientists in industry and the public sector access vital information from a world-wide network of resources.
CISTI Information Specialists save you precious time and money because they're connected to the most current and complete information resources. They can pinpoint specific data with unmatched efficiency. For more information about CISTI, and our new "Urgent Services", contact: Canada Institute for Scientific and Technical Information
at (613) 993-1600 or fax (613) 952-9112. To get you the information you need while it's hot, we'll even deliver!
Ntcctac
1^1 Council NationalCanada Research de Conseil nationalCanada recherches
Canada
For more information, Circle reply card No. 114 42
TRC within the receiving stream body were found to be a function of the hyd raulic mixing characteristics of the re ceiving stream and of the chemical decay of the residual chlorine. First order decay coefficients for TRC were obtained by modelling the chlorinated plume mixing and fitting the decay co efficient to the observed field data. Model of the Anaerobic Granule Consortium
Biotechnology Research Institute scien tist S.R. Guiot together with University of Calgary's J.W. Costerton and a French colleague have provided a model of the anaerobic granule consor tium. Their paper in Water Science and Technology presents a synthetic review of studies conducted recently and con solidated by other literature insights that substantiate a multi-layered struc-
Environmental Science & Engineering, March 1993
R&D News tured model ofthe population organiza tion in the anaerobic granule. Syntrophic bacteria associations would be located „ between an external, pre dominantly acidogenic. layer including also H2-consuming bacteria, and an aceticlastic core. Such a structural ag gregate is a stable metabolic arrange ment that creates optimal nutritional conditions for all its members.
Removal of Metals from Municipal Sludge J.F. Blais and coworkers at INRS-Eau
studied metal removal from municipal sludge in laboratory reactors by acid
league have traced environmental changes which have accompanied de velopment around the Rochester Basin
and rivers compare favourably with conventional methods.
of eastern Lake Ontario based on the
Settling of Fine-Grained Sediment
hydrocarbon content of sediments. As described to delegates attending the an
Knowledge of the settling characteris tics of fine-grained sediment is impor tant for designing and operating reser voirs and settling ponds. National
nual conference of the International
Association on Great Lakes Research,
the sediments prior to the mid-1800s contained low concentrations of hyd rocarbons that are dominated by landplant wax components. The concentra tions of these have continued to rise since the late 1800s as the erosion of soil and nutrients from watershed areas ac
celerated. Petroleum began to appear in
Water Research Institute scientist B.
Krishnappen has developed a computer model which can realistically predict the settling times ofsediments in a vari ety of settling ponds because it accounts for the previously overlooked process of flocculation. The model can be used to
treatment and two microbial leaching processes. As described in Water Science and Technology, the use of a microbial leaching process with elemental sulfur
the late 1800s and has become an im
evaluate the efficacy of ponds in trap ping fine sediments from agricultural
portant portion ofthe hydrocarbon con
and other sources.
and/or ferrous sulfate as substrate re
Acid Volatile Sulfide in Freshwater Sediments
quired less acid for metal extraction and reduced the metal content by 83-100%. A five day bioleaching process using sul fur oxidizing bacteria, with sulfur as the substrate, was superior to a 10-day pro cess using iron oxidizing bacteria with ferrous sulfate as substrate.
Pollution History by Sediment Core Analysis National Water Research Institute sci entist R. Bourbonniere and a U.S. col
tent of modern sediments.
For more Information,contact Dr. H.R. Eisenhauer, Canadian Asso
I. Sekerka and J.F. Lechner have devel
oped a reliable, efficient procedure for determining acid volatile sulfide in freshwater sediments. The approach of these National Water Research Institute
scientists is based on converting the ionic sulfide into gaseous hydrogen sul fide by treatment with an acidic solution and then quantitatively monitoring the gas produced. The results obtained for
ciation on Water Pollution Re
search and Control, Conservation and Protection, Environment Canada, Ottawa, ON K1A 0H3, Fax:(819)953-9029.
sediments from various Canadian lakes
Newfor Wastewater Testing Optional self-cleaning By-Pass Y Strainer is now available to reduce clogging and fouling
Hach CL17
Chlorine Analyzer Around-the-clock monitoringforjust pennies per hour* The CL17 Chlorine Analyzer provides the contmuous, accurate, on-line monitoring
required for optimum chlorine residual control. Thousands of facilities have discovered that the CL17 is the affordable way to eliminate expensive overfeeding while assuring full-time compliance.
■ USEPA-approved DPD colorimetric chenustry (for drinking water and wastewater) ■ Operates unattended for 30 days between reagent changes ■ Dual programmable alarms ■ Selectable recorder output and optional computer interface kit *Based on five years of use excluding depreciation
For more information, request literature numbers 3879 and 1320. HACH COMPANY P.O. Box 389 Loveiand, Colorado 80539 U.S.A. Service Centre in Winnipeg
Sales outlets throughout Canada
Telephone:(303)669-3050 Fax:(303)669-2932
For more information, Circle reply card No. 115
Environmental Science & Engineering, March 1993
43
By James Higgins, Ph.D., P.Eng.^
Environmental economics
Global environmental market could reach
$US454 billion by year 2000
Theannual watersupply budget in the United States amounts
to US $100 to $150 billion. The Associated General Contrac
tors (AGC) estimate American water
and wastewater treatment area.
There is a continuing trend towards the use of more secondary sewage treat ment (biological bacterial degradation of dissolved organic solids) and tertiary
ment. BC has a poor record with only 55% primary treatment.20% with secon dary and a further 20% discharging di rectly into receiving waters with no treatment at all.
supply infrastructure needs $139 billion between now and year 2000. Potable water treatment facilities will require $4 billion in work annually and the water purification equipment and services
sewage treatment (chemical removal of nutrients, metals and dissolved inorga nics). The Atlantic provinces have the poorest records in the area of sewage
The U.S. government expects US $60 billion to be spent by the year 2000 in order to meet requirements of the Clean
treatment. Newfoundland,for instance,
pal wastewater treatment capital expen
market has been forecast at $8 billion
discharges over 80% of its sewage un treated even by primary treatment(me chanical removal of solids). Quebec also has a very poor record with 65% of sewage from communities over 1000 re ceiving no treatment and much less than 20% receiving only secondary treatment.(The province has. however, committed to provide at least some
ditures will total about $3 billion by 1995. with three times this amount being
annually in 1990.
In Canada, there are approximately 1500 sewage treatment facilities serving about two thirds of our population. The rest either are not connected to collec
Water Act amendments of 1987. Munici
directed towards operations and main tenance.The AGC estimate $508 billion
will have to be spent before the year 2000 on U.S. wastewater treatment infra
tor systems or discharge sewage di rectly into bodies of water. Although the percentage of Canadian communities with some form of sewage treatment in
treatment for all communities over 5000
Solid Wastes Handling and Control The Solid Wastes Handling and Con
creased from 63% in 1983 to 70% in 1989.
by 1995.) In Ontario the situation is
trol area involves the collection, han
over 700 ofthem will require new sewage treatment plants. These plus upgrades of sadly neglected existing facilities will
much better with over 60% of com
munities having some level of tertiary
dling. treatment and disposal of ordin ary solid wastes (municipal, industrial
treatment and a further 15%.secondary.
and commercial), hazardous wastes
provide long term opportunities for en vironmental companies in the water
structure.
On the prairies. Manitoba has the best
and a variety of special wastes (e.g.. nu
record with over 90% secondary treat
clear. toxic, medical)as well as facilities,
products and services involved with re cycling. incineration and other solid TABLE 1 GLOBAL ENVIRONMENTAL MARKET BY TERRITORY
waste treatment facilities. Already American public spending for solid waste disposal amounts to US $7 billion annually while in Canada it amounts to
($US Billion) YEAR 1990
YEAR 2000
$600 million.
NORTH AMERICA 115
154
CANADA
7
12
MEXICO
3
19
125
185
UNITED STATES
EUROPE UNITED KINGDOM FRANCE GERMANY REST OF EEC REST OF W. EUROPE
EASTERN EUROPE/CIS
ASIA/PACIFIC JAPAN AUSTRAL1A/N.Z. TAIWAN
HONG KONG S. KOREA REST
11
29
10
21
21 15
36 34
6
12
15
22
78
154
24
39
2
3
5
30
â&#x20AC;&#x201D;
1
3
14
8 22
46
105
Air Pollution Control The Air Pollution Control area in
volves air pollution control equipment and instrumentation,scrubber technol
ogy and systems,pre-treatment technol ogy. combustion modification tech niques. continuous air monitoring and analysis systems and indoor air quality systems. With new legislative initiatives such as recent amendments to the U.S.
Clean Air Act and Ontario's proposed Clean Air Program (CAP), many feel par ticular growth will occur in this area over the next few years. Expenditures on air pollution abatement from mobile sources (e.g.. cars and trucks) totalled US $20 billion in North America in 1985
while a further $18 billion was spent on abatement from industrial, public and other stationary sources. Water and Wastewater Treatment The field of water and wastewater
treatment is a particularly broad area to REST OF WORLD
TOTAL WORLD
6
10
255
454
*Environmental Technologies Deve lopment Corporation, Toronto, On tario.
44
Environmental Science & Engineering. March 1993
I
J 1!^
M
1^.
TGO
TOTAL sludge handling, transport, and storage than anyone else in SYSTEM Unmatched engineering exper SOLUTION! •tise, proven in major projects
There are many companies in the field of siudge handiing, transport, and storage that can seii you various bits and pieces of a siudge system. But at Asdor, we offer you something more...The Total System Solution to all your sludge problems! This includes some of the finest, field-proven sludge handling equipment in the world, such as: •Edwards & Jones Filter Presses
•Spaans Shafted and Centerless Screw Conveyors •Putzmeister Cake Pumps •Spaans Archimedes Screw Pumps But ail of these, as robust and time proven as they may be, are stiii just pieces of the big picture. Asdor's Total System Solution completes the pic ture by providing you with the foiiowing vaiue-
North America.
worldwide, including L.A., Cairo, Washington, Columbus,Toronto, & San Antonio. •innovative design capabilities to meet even the most difficult challenges. •Budget oriented and time sensitive project management skills, with on-site responsibility. •The ability to draw upon the vast, worldwide tech nical and financial resources of Asdor's family of associated companies. Why go to pieces over your sludge handling needs? Let Asdor's unique Total System Solution replace 'piece' meal answers with peace of mind.
added features:
For a free needs assess
• More years of experience in every phase of
ment, please call or write us today.
1255 Nicholson Road
Newmarket, ON L3Y 7V1 (416)836-7700 For more information,
25 Main Street
Belleville, NJ 07109-3057 1-800-387-3635
See us at the OPCEA Show.
Circie reply card No. 104 45
which society will have to pay particular attention in future. The Potable and In
few very large players (e.g., Laidlaw. Waste Management Inc.. BFI). Annual
dustrial Water segment involves water supply, purification, water disinfection,
revenues in North America for this sec
panies have diversified into the Envi ronmental Services sector,(e.g., Laidlaw
tor are already more than $30 billion.
with Tricil and WMI with Chemical
groundwater monitoring, laboratory testing and technologies for water treat ment. The Wastewater Treatment seg ment involves the collection, treatment
Many Waste Management .sector com
Waste Management).
Environmental Services Sector
Closely related to the Waste Manage
Environmental Equipment Sector
ment seetor is the Environmental Ser-
The supply ofequipment for the envi ronmental industry is a large, highly fragmented sector. There are thousands of firms which supply everything from
and disposal of industrial and munici pal wastewaters, wastewater treatment
technologies and the remediation of
instruments to incinerators. The North American market for this sector is at least $15 billion. Here in Canada the
contaminated water streams.
In Canada over 90% ofthe population — 2500 communities — are connected
market is already $1.4 billion, having grown a whopping 43% in the last five years. We believe the equipment sector (and the related environmental techno logies sector) will continue to show strong growth, becoming the predomi-
to some sort of water supply system. Water demand is growing at 12% per year, much higher than population growth. However,continuing deteriora tion of existing infrastructure, strong demands for new facilities, forecasts of
water shortages, conservation activities, and heightened public awareness of and concern for water purity will make water purification and supply a strong growth area during the 1990s. Waste Management Sector The Waste Management sector is the largest sector and involves the collec tion, handling, disposal and brokering of both hazardous and non-hazardous
wastes, and often the operation oftrans
nent sector in the environmental field.
Dr. Higgins
vices sector. This rapidly growing sector encompasses such areas as the opera tion of treatment plants, recycling plants, composters, specialty materials handling facilities, incinerators and used oil recovery facilities. Also includ ed are businesses carrying out water and air pollution monitoring services for industry. Annual revenues for this sec
fer stations and landfills. The sector is
tor in North America are in the $10 bil
fiercely competitive and dominated by a
lion range and growth rates are high.
Environmental Technologies Sector This is the largest sector and is a catch-all area which comprises a wealth
of processes, technologies, products, chemicals,organisms,catalysts and ma terials. Often it is associated with par
ticular types of equipment. It is the least evolved of the market sectors but is be
coming increasingly important as waste generators draw on new technologies to continued
Liquid and Diy Storage Systems with the "No Painting" Difference
one msu transportable safety handle secures a multitude of holes
6ild5S-fused-fo s/ee/ hcfth ^ides for bu/ ^ainfer)3ir\ce
Urdhane sealant
jpetween alljofirfs. Bolted consfntcfion
and lonq
lif&. ^ Hiqh malihi
hrdfswifh. -
s\jsterv\ allows
tasi!erecfioni djsdssemhlu ^rejocMion.'
corrosion-
safe!handle
rtsisfzinf phstio &t\C9psul3fcd htdUs.
MSU MISSISSAUGA LTD. 2222 South Sheridan Way, Mississaugo Ontario L5J 2M4
For complete information 1-800-268-5336 Fox: 416-823-4947 For more information, Circle reply card No. 108
Aquastore® and Permaglas® Storage Systems are the ultimate in flexibility, durability and low maintenance.
Greatario Industrial Greatario Industrial Storage Systems Ltd.
Get full details by contacting:
P.O. Box 3613, Gueiph, Ont. NIH 6P1 Telephone (519)«763«5933
Storage Systems Ltd.
46
For more information, Circle reply card No. 109
Environmental economics cont'd reduce pollution. Due to the variety of participants, this sector defies precise quantification and probably exceeds $5 billion per year.
Analytical Services Sector Over 1,000 companies make up this fragmented sector which is concerned with the analysis of samples to deter mine the existence,extent and character
Remediation Sector The remediation market sector is less
fragmented than others and involves fewer companies. It includes those that clean up waste sites, ones involved in decommissioning services, cleaning up oil, chemicals and other spills, and firms involved in asbestos removal and
disposal. The sector enjoys revenues of about $5 billion annually and growth rates average 10% in most of its subsectors, with some growing at 25% per year or more.
Consulting & Engineering Sector This sector involves several hundred
firms, usually relatively small and pri vately-held ones. It covers not only the design of pollution control facilities, but also consultation and interpretation on environmental laws, project engineer ing,environmental audits,environmen tal risk analyses, compliance audits, as sistance with obtaining environmental permits, and a host of other activities. Many firms have geographical and/or technical specialties. Sector growth rates are above 25% per year in many cases and the sector market is in the $12
billion range.
of contaminants. Competition is strong and is growing as more companies seek
The world market for
tions and many others. In some cases,
the services provided are only a part of the services the organization in total provides, (e.g., part of a law firm may devote itself to environmental law).This sector is worth at least a billion and pro bably worth several billion dollars an nually in North America. Global Environmental Market
products, technologies, processes, and services for cleaning up the environment
The world market for products, tech nologies, processes, and services for cleaning up the environment was esti
was estimated to be worth about US $255 billion in
in 1990 and is projected to grow at about 6% per year to $454 billion by the year
1990 and is projected to grow at about6% per year to $454 biiiion by the year 2000.
ready estimated to be anywhere from
mated to be worth about US $255 billion
2000. The total Canadian market is al
US $5 to 7 billion annually. We agree
with the latter figure and feel it will grow to exceed $12 billion by the year 2000. In the U.S., the environmental market was
worth $115 billion in 1990 and is grow
to compete in an already crowded mar ket currently worth about $2 billion in North America alone.
ing at about 5% per year. Indeed, the American market already makes up over 2% of GNP and this too is expected
to grow. In the European Community, the market is already worth about 51
Information Sector
This last sector is a grab bag of areas providing support services to the other environmental industry sectors and to the customers they serve. Included are market research companies, insurance companies, law firms, financial institu
billion ECU and there it is forecast to
grow at8% per year between now and the year 2000. For more information,
Circle reply card No. 116
Anniversary
Ontario Conference ON THE Environment (formerly Ontario Waste Management and Industrial Waste Conferences)
June 13 - 16, 1993 ❖ Four Seasons ❖ Inn on the Park ❖ Toronto, Ontario The Ontario Conference on the Environment will provide new insights into environmental problems and solutions.
Pollution prevention ❖ 3Rs and waste reduction ❖ Multi-media technologies ❖ Eco-system approaches for cleaning up and restoring land, water and air For more information please contact: Ministry of the Environment, 12th floor, 2 St. Glair Ave., W., Toronto, Ontario M4V 1L5
Attn.: Murray Cheetham, Conference Co-ordinator,
® Ontario
Phone:(416) 323-5184 Fax:(416) 323-5031 For more information, Circle reply card No. 110
Environmental Science cfe Engineering, March 1993
47
/li bV 'v r/' 7th ANNUAL
(,i»«»^TORONTO ENVIRONMENTAL TRADESHOW AND CONFERENCE formerly HAZTECH CANADA
May 11 & 12, 1993 Toronto International Centre of Commerce, Misslssauga, Ontario, Canada
BOOK YOUR EXHIBIT SPACE TODAYI For further information contact:
Canadian Exhibition Management Inc. #240, 4936 - 87 Street Edmonton, Alberta, Canada T6E 5W3
Phone: (403) 469-2400 Fax: (403) 469-1398
For more information, Circle reply card No. 105 48
-
,
-
> ■
Environmental Science & Engineering. March 1993
E^o
o C d)
Ss-g « >
joWg
!t ® S 0 ® a
18 B £ e 'I m ® E
(/)
_
CO
CO
(0
E CO
(D
^ <b \
£
CO
^
E o <u —^ "O ^
Q. 0) D
E CL T3
□□□□□
O > D. _I O
^ o€.i:£
:3 > ® o
~ ^ I CO .£
TO i: i_ ro ®
<D
zo O °) 58 .O D -JS ® C ® O ^ c O) M o 2 5 CD Z o — C
<.E o o
lu ® ® 5
i®^o 3 ® O£ (O au.?
,E □
S O 5 58
®
N
>
CO c
< O)
®
c
-§ >><CD cox. I" 55 > ® ® 9?
'3 < 15 -i >o □
> CL F O < Q
□□□□
m ^•--
ES&t MAR/93
SEWER PROBLEMS?
Save time and money with no-dig
U-Liner™ pipe.
Pipeline Rehabilitation
High Density Polyethylene
Fast — Trenchless
Long Continuous Lengths
Tight Fitting
Laterals Cut Internally
U-Line
Vancouver
(416) 607-0011
Toronto
SafcHL HHi DIIIEB.EQ
(604) 574-1366
Please fill in other side & mail.
Over 1100 Pages of the Most Current
Information on Environmental Engineering
$134.95, 0-07-013158-9
1152 pages, 365 illus.
STANDARD HANDBOOK OF ENVIRONMENTAL ENGINEERiNG by R.A. Corbitt
field, this first-of-its-kind hand
Written by 36 top experts in the
book helps you put important environmental engineering
principles into practice. Principles and techniques are IllustratecJ
with over 900 tables, charts,
drawings, and photographsproviding essential technical data and helpful engineering guide
lines. Individual chapters are devoted to air quality control,
management.
water supply, wastewater disposal, solid waste management, stormwater and hazardous waste
copy(ies) of Standard Handbook of Yes, send me Environmental Engineering @ $134.95 (O 07-0i3i58-9)
Tel.#:
□ AMEX
Valid Date:
□ MASTERCARD
Accept my*: □ Enclosed Cheque/Money Order
□ VISA Card No:_
Street:
Expiry Date: Signature: Name:
City/Prov.:
Postal Code:
ES&E MAR/93
*add $3 for the first book, plus 50 cents for each additional book ordered, for shipping & handling. Add 7% GST to total (after shipping).
Product Review New auto-start, silent pumping unit
Canadian made aluminum access hatches MSU Mississauga has introduced the Type M Access Hatch. The watertight, gasketed drain chan nel keeps water out of underground structures; this is particularly important for drinking water reservoirs. The con tinuous piano hinges are attached with vandal-proof, stainless steel hardware. Gas springs are supplied with etich hatch to assure easy operation and max imum safety. The Type M is of flush design; the operator is not exposed to any trip hazards.
MSU Mississauga is certified by the Canadian Welding Bureau to CSA
Standard W47.2-m"1987. MSU Mississauga For more information, Circle reply card No. 172
New Product Recovery System
Gorman-Rupp has introduced a new. portable sewage pumping system de signed for emergency standby and sewage-by-pass operations.
jBP*
The silent unit features a 6" T-Series
self-priming, centrifugal solids han dling sewage pump with submersible transducer liquid level control. Fourcylinder. air-cooled diesel engine and pump are close coupled to prevent mis alignment of the rotating members. Extra large capacity fuel tanks hold enough fuel for 24 hours of continu ous operation. Sound-proof installation provides quiet operation and the entire unit, in cluding controls, can be locked for added security for unattended automa tic operation. The pump system is mounted on tough steel frame with tor sion bar suspension and hydraulic surge brakes for easy maneuverabilit\ on the highway or in the field. Gorman-Rupp
The model Keck PRS-90 is designed for the efficient recovery of floating hyd rocarbons. It uses a stainless steel blad
der style pneumatic pump coupled to a unique floating skimmer attachment. This skimmer attachment is available
for 2 inch and larger wells and can ac commodate ground water fluctuations in excess of 24" (longer travel attach ments available.)
Laboratories
BARRINGER LABORATORIES
Where your concerns are our concerns QUALITY - TURNAROUND - PRICE
For more information, Circle reply card No. 170
5735 McAdam Road, Mississauga, Ontario L4Z1N9 Cold water meter
416-890-8566 Toll Free: 800-263-9040 Fax:416-890-8575
Kent Meters T-3000 turbine cold water
meter, with large S'A" hermetically sealed register can be easily read. The hermetically sealed register is permanently sealed and is nitrogen filled to prevent condensation. The meter functions well, even completely under
ini lUM lA
water. The turbine T-3000 meter is de
BA5 Labomtories Limited
Consulting Environmental Chemists
signed for applications where larger pipe sizes and Hows are required. The meter is available in sizes \ Vi" through 12". with flow ranges from 4 GPM to
Excellence in
Environmental Analysis for Over 25 Years 14 Abacus Road Phone (416) 794-2522 Brampton, Ontario Fax (416) 794-2338 Canada L6T 5B7
6500 GPM.
The turbine meters unique throated design increases the lluid velocity through the meter, greatly enhancing low flow metering accuracy. The taped shape of the working chamber allows easy removal for inspection or service when the top cover is removed, without having to remove the meter from the line. Kent Meters
For more information.
Circle reply card No. 171
(TMxrnsr
CanTesl Ltd Professional
Analytical Services Suite 200
Environmental Analysis
1523 West 3rd Ave
Vancouver, B.C.
Hazardous Waste Characterization
V6J 1J8
Occupational Health & Safety
Tel: 604 734 7276
Fax: 604 731 2386
OVER 20 YEARS OF ANALYTICAL EXCELLENCE
Environmental Science & Engineering, March 1993
49
Laboratories
Product Review The PRS-90 is designed for field por tability and rapid installation.
Comprehensive • Complete MISA Parameters
Environmental
Geneq Inc. For more information,
• Regulation 309 Compliance
Circle reply card No. 173
• Dioxins/Furans
• Air Analysis • Soil Decommissioning
Laboratories
• Ontario Drinking Water Criteria
New flow and plug systems
CANVIR®
Filter Innovations new flow and plug systems continuously remove oils and organiccontaminants from industrial &
50 Bachurst Drive, Waterloo, Ontario N2V 2C5 Tel: (519) 747-2575
Fax; (519) 747-3806
natural waters.
Jg Chemex Labs Ltd.
ElECTRir
►Water Potability Testing ►Contaminated Sites Testing
PRNEL
►Waste Characterization
►Sewer Discharge Sampling & Testing ►Acid Rock Drainage Prediction ►Accreditations with CAEAL and BCMOE
Vancouver, BC (604) 984-0221
Clayton ENVIRONMENTAL CONSULTANTS
A Marsh 8i McLennan Company
949 McDougall Avenue Windsor, Ontario N9A
1L9
Mississauga, ON (416) 624-2806
FR- 90 BHG flLTD?
FJI-50
ENVIRONMENTAL AND INDUSTRIAL HYGIENE
CHNNlSTfR
ANALYTICAL LABORATORY SERVICES
Regulation 3D9 • Metals • Inorganics • Organics Volatile Organics ' BTEX • Asbestos • RGBs Gas Bag Analysis • Odour Panels • Isocyanates
Inquiries about additional analytical services are encouraged (519)255-9797
HCWTiR
FAX (519)255-9304
Setting the standard for
to sewers or natural watercourse.
* service
iS ENVIRONMENT PROTECTION LABORATORIES INC.
The discharge systems permit con tinuous process operations while meet ing or exceeding government regula tions for the direct discharge of etiluents
* quality turnaround time
6850 Goreway Drive, Toronto, L4V IPl, Tel: (416) 673-3255, FAX: (416) 673-7399
Each "System" has two important fea tures: (a) It permits the continuous absorption or oil. greases. PCBs. pentachlorophenols. (b) Upon saturation it signals and shuts down the discharge systems. Filter Innovations For more information,
Circle reply card No. 174
Meeting the needs and expectations
Respirometers
of our clients with accurate defensible data
The real time data that wastewater oper
for environmental decision making.
ators
ENVIRGCLEAN laboratories inc. (519)686-7558
LONDON
1-800-268-7396
receive
from
the
Arthur
res
pirometers are an inside look into what is goingon biologically within the waste-
/I -LAldlL TT.jyi'i mf '
FINE ANALYSIS LABORATORIES Complete analytical services conducted according to MOE, EPA, APHA, ASTM at competitive prices. ENVIRONMENTAL* ORGANIC* DRINKING WATER AGRICULTURAL* SOIL* INDUSTRIAL* INORGANIC WASTEWATER * METALS * FEED
LABORATORY RESPIHOMETER
Packages include: 35 Parameter of water quality analysis ($55.00/sample) 16 Parameter of soil quality analysis ($50.00/sample)
With FINE ANALYSIS LABORATORIES you can be assured of high quality,
prompt service and an average turn around time of 4 business days.
ON-LINE RESPIROMETEB
83 BIGWIN RD., UNIT #8, HAMILTON, ONT. LOR IPO (416) 574-4977 50
Eiivironmemal Science & Engineering. March 1993
Product Review water treatment process.
ditions such as for frost protection.
The laboratory and on-line instru ments report anticipatory wastewater operation data that mean protection for
Sensus
For more information,
Circle reply card No. 176
the biomass from toxic kill and shock loads, determination within 10-15 min
utes of inOuent treatability and fast readouts of the amount of food (BOD) present at any point in the treatment
troduced a new six page brochure des cribing its complete line of rotating screen systems for the removal of gross solids from municipal and industrial wastewater streams.
New brochure on
rotary screens Pollution Control Inc. has recently in
process. The operator can predict llnal BOD within minutes, and can quickly see the effect of adjustments he makes to the rate of return sludge, length of treat
The PCI rotating micro screens are designed for optimum solids removal with the ability to easily change the
Laboratories/Consultants Comprehensive Environmental Anaiyticai Services Air Quality • Water Quality • Hazardous Waste
ment time or the amount of aeration.
The respirometers use unique short term tests that were developed by Arthur Technology and are taught at two-day customer training schools.
' Complete MISA Parameters
• Emission Testing
' Reg. 309 Compliance • Polychlorinated Dibenzodioxins/Furans » Ambient Air Monitoring
• Ontario Drinking Water Criteria
Arthur Technology
• Odorous Compounds • Rush Analysis Available
Mann Testing Laboratories Ltd.
For more information, Circle reply card No. 175
Professional Analytical Services Since 1972 5550 McAdam Road, MIsslssauga, Ontario L4Z 1P1 Phone: (416) 890-2555 Fax: (416) 890-0370
Sensus SR II® water meters
xral environmental
Sensus SR II water meters are available
A DIVISION OF SOS SUPERVISION SERVICES INC.
in %" through I" sizes and include a
ANALYTICAL SERVICES
selection of direct read and electronic
encoder registers for use with the TouchRead® System and other Sensus automatic meter reading (AMR) sys tems.
MiSA • Process/Wastewater • Soil • Solid Waste
Elemental Scans • Characterizations • RGB's • Sampling "16 SGS Locations Across Canada"
1903 Leslie St. Don Mills, Ontario MSB 2M3
Tel: (416) 445-5809 Fax: (416) 445-4152
ZENON ENVIRONMENTAL LABORATORIES "QUALITY ASSURED—DELIVERY GUARANTEED" PROVIDING COMPLETE ENVIRONMENTAL ANALYSIS ACROSS CANADA
Burlington, Ontario (416)332-8788 Vancouver, B.C.(604)444-4808 Montreal, Quebec(514)493-4733
Ainley and These oscillating piston-type positive displacement meters have bronze maincases guaranteed for 25 years and fea ture a specially designed hydro-dynamically balanced piston in a dualported measuring chamber to provide plenty of long lasting service. Measure ment accuracy is guaranteed to meet
A COLLINGWOOD
Associates Limited CONSULTING ENGINEERS & PLANNERS
BARRIE
280 Pretty River Parkway
48 High Street
(705) 445-3451 Fax (705) 445-0968
(705) 726-3371
Fax (705) 726-4391
OTTAWA
BELLEVILLE 205 Dundas Street
Box 917, R.R.5
(613) 966-4243 Fax (613) 966-1168
(613) 822-1052 Fax (613) 822-1573
AWWA new meter standards for fi ve full
years and repaired meter accuracy stan dards for an additional ten years — a full 15 years of guaranteed accuracy. SR
II
Water
Meters feature
her
metically sealed registers housed in a special locking bonnet. The registers can be exchanged without removing the meters from service by using a special tool. The meters are available with steel,
bronze or engineered plastic bottom plates to meet a variety of service con
ALTECH ENVIRONMENTAL CONSULTING LTD.
Environmental Auditing and Management Planning Waste Management solutions to the 4 Rs Wastewater Treatment
Environmental and occupational health and safety specialists Serving industry in Canada
design engineering Air, soil, waste and water analytics, studies and Iroubleshooting
225Sheppard Ave. W., Willowdale, Ontario M2N 1N2
Environmental Science & Engineering, March 1993
(416)226-0148 51
Product Review
Consultants
mesh size to adapt the screening system to the prevailing characteristics of the wastewater stream.
R.V. Anderson Associates Limited consulting engineers and architect Water Pollution Control
Water Supply
L
Water Resources
Environmental Planning Land Development Transportation Tunnels and Shafts Municipal Services Architecture
TORONTO (416)497-8600
WELLAND (416) 735-3659
OTTAWA
SUDBURY (705)671-9903(Dennis Consultants)
(613)226-1844
Aquatic Sciences Inc.
OSHAWA (416)434-2544
Environmental Scientists Commercial Divers
UNDERWATER AND ENVIRONMENTAL SERVICES
The system operates with the was tewater streatn flowing to the interior of a horizontal drum which is comprised of the screening panels. The wastewater will pass through the screens with the solids being retained within the interior of the drum. The solids then move via a
series of baffles or plows to the opposi ng end of the drum for further dewatering and/or disposal. Typically the was tewater which is reclaimed is recycled back through the biological treatment system. Pollution Control Inc. POLLUTION CONTROL INC.
• spil l site investigations and cleanups • underwater video inspections
• impact assessments
'Si
• water quality monitoring
P.O. Box2205, Station B, St. Catharines, Ontario L2M 6P6
li)S Driinishticir Ki»li»rv Screens
(416)641-0941
w
ENVIRONMENTAL ENGINEERING SERVICES
y INTERNATIONAL
BRITISH COLUMBIA SASKATCHEWAN ALBERTA
ONTARIO
ASSOCIATED ENGINEERING For more information.
C.C. TATHAM & ASSOCIATES LTD. Consulting Engineers
Circle reply card No. 177
Smart flow transmitters
Specialists In a comprehensive range of Environmental and Municipal Engineering
Seaflow".s new FT400 flow computer, when combined with their wide range in.sertion flow sensor, makes a powerful field adjustable How system. The FT400 flow computer is mounted in a module directly on the How sensor which is inserted into the pipe line by a
115 Hurontario Street, Suite 201,
Collingwood, Ontario 1.9Y 2L9 Tel.(705)444-2565 Fax(705)444-2327
one and one half inch or two inch con
I
Consulting Engineers
CH2MHILJ.
ClfMHILL, ENGINEERING 5 Waterloo • Toronto • Calgary • Edmonton • Vanqpuver • Lethbridge
• Wastewater Collection & Treatment
■ Hazardous & Solid Waste Management • Water Resources & Environmental Planning
• Water Supply Strategies • Analytical Testing • Field Sampling & Flow Measurement
nector. It is field programmable in eight digit digital display for rate and total. 4 to 20 milliamp output pulse output. Sensor/Computer range is from 2 gal lons a minute in a one and one halfinch
pipe to 7300 gallons a minute in a ten inch pipe (0.3 to 30 feet per second.)
WINNER OF THE AWARD OF EXCELLENCE - WASTEWATER
Sealand Sales
CANADIAN 1990 NATIONAL ENVIRONMENTAL AWARDS PROGRAM FOR THE STUDY <S DESIGN OF A MUNICIPAL SLUDGE MANAGEMENT SYSTEM
Clayton
For more information, Circle reply card No. 178
SPECIALISTS IN ENVIRONMENTAL
ENGINEERING,INDUSTRIAL HYGIENE,
New on-line turbldlmeter
AND LABORATORY SERVICES
ENVIRONMENTAL CONSULTANTS A Ivlarsli & IvtcLennan Company
WINDSOR [519)255-9797 TORONTO (416)498-7444
52
• Underground Storage Tank Management, Investigations and Remedlations
Tile new Micro 200on-line turbidimeter offers the ultimate in ease ofuse. while at
' Environmental
the same time,offeringgrealer accuracy. The Micro 200 incorporates a mem
Assessments I
Ambient Air Monitoring and Source Testing Analytical Laboratory Services
Audits
brane keypad user interface, a long life, easy to change lamp module, conden sation-free measurement, and text help Enviroiimeiital Science & Engineering. March 1993
Product Review
Consultants-
screens to guide the user. This ensures that all routine maintenance from calib
ration to cleaning to lamp replacement is performed without any tools. The Micro 200 provides ±1% accur acy and 0.0001
resolution
on the
0-1.0000 NTU range. Full scale range is 100 NTU. The sensor configuration al lows for easy cleaning, no condensation and most importantly, an immediate response to a change in turbidity.
□ELCAN
SISs
Eastern Region Toronto Tel: (416M41-4111
SPECIALIZING IN:
Fax: (416)441-4131
• ENVIRONMENTAL ASSESSMENT AUDITS S PLANNING
Prairie Region Calgary
• MUNICIPAL AND INDUSTRIAL WASTEWATER TREATMENT
Tel: (403) 276-9861
• PLANT DECOMMISSIONING
Fax: (403) 277-6902
• SITE REMEDIATION
Pacific Region
• SOLID AND HAZARDOUS WASTE MANAGEMENT
Vancouver
. WATER SUPPLY. TREATMENT AND DISTRIBUTION
Tel: (604) 525-9333
Offices across Canada and Overseas
Fax: (604) 525-9458
HP Scientific
For more information, Circle reply card No. 179
PIILLOn Professional Consulting Services Planning Engineering
Display graphics for turbidity
Environmental Science
The new Micro 200 BW on-line tur-
hidimeter introduces display graphics to the measurement of turbidity. The unit provides a graphic history of tur bidity for the previous 24 hour period, often eliminating the need to review chart recordings. The Micro 200 BW also incorporates ESP (Extra Sensor Perception) to allow connection of the optional backwash sensor. Properly
Toronto * London • Cambridge • Windsor • Ottawa • Halifax • Sydney Fredericton • Winnipeg • Edmonton • Red Deer • Ye II o w k ni f e • International 100 Sheppard Avenue East. Toronto. Ontario M2N 6N 5 (4 16) 229-4646
Consultants In
used the backwash sensor will allow
• Environmental Planning • Ecological Science
operators to minimize the amount of
• Geosclence
• Planning • Implementation • Monitoring • Remediation
Gartner Lee TORONTO (416)477-8400
VANCOUVER (604)299-4144
NIAGARA FALLS, NY (716)285-5448
COMPREHENSIVE CONSULTING SERVICES IN ENGINEERING AND ENVIRONMENTAL SCIENCES INTERNATIONALLY
0.0001 resolution on the I NTU range. The Micro 200 BW will easily provide raw water, settled water, filter effiuent. filter to waste finished water, and back
wash turbidity measurement using one measurement system. HP Scientific
Golder
'Associates
For more information, Circle reply card No. 180
Single point level detection system
U—PI
• Engineering
water needed to backwash a filter while
ensuring that the filter has been cleaned to a predetermined standard. In the turbidity mode the Micro 200 graphically displays the current reading as well as the high. low. and average for the previous 24 hour period. The Micro 200 provides accuracy of ±1% and
The Environment
© GOODFELLOW CONSULTANTS INC.
50 offices throughout Canada, the United States. Australia and Europe. BURNABY MISSISSAUGA
Tel: (604) 298-6623 Fax: [604] 298-5253 Tel: (416)567-4444 Fax: (416)567-6561
Environmental/Occupational Health and Safety PROFESSIONAL CAPABILITIES: • Workplace and safety audits
> Environmental Engineering "Training programs • Legal compliance/designated substances " Ventilation assessment/design • Air monitoring " Air emission control • Indoor air quality " Environmental audits • Noise monitoring and control •WHMiS
• Asbestos
20(X) Argentia Road, Plaza III. Suite 301 Mlsslssauga, Ontario L5N 1V9 Canada • (416) 858-4424
Telex: 06-218242
Fax: (416) 858-4426
Gore St Storrie Limited Consulting Engineers WASTEWATER • WATER • SOLID & HAZARDOUS WASTES • DRAINAGE WATER RESOURCES • ENERGY RECOVERY • ENVIRONMENTAL PLANNING LABORATORY SERVICES - ANALYTICAL & PROCESS R&D
The new model I3L single point level detection system features high quality construction for superior performance
255 Consumers Road, North York, Ontario M2J 5B6 Telephone (416) 499-9000 Fax (416) 499-4687
Ottawa • Thorold • Barrie • Cambridge • Mississauga • Kingston • London
in conductive and non-conductive ma-
Eiiviiviinieiilal Science & Engineering. March 1993
53
Product Review
Consultants
Hydromantis,Inc.
1685 Main St. West, Suite 302 Hamilton, Ontario L8S 1G5
Consulting Engineers
FAX (416) 522-0031
Tel. (416) 522-0012
Water and Wastewater Engineering • Water Resources Modelling • Simulation • Integrated Computer Control Expert Systems • Neural Networks
s
Consultants for water and pollution control projects
Knox Martin Kretch Limited Consulting Engineers, Planners, Landscape Architects
a
220 Advance Boulevard, Brampton, Ontario. L6T 4J5 (41 6) 459-4780 Fax. (41 6) 459-7869 Kitchener (51 9) 743-61 1 1 Cobalt (705) 679-5979
terials of all kinds. Its integral level sens ing element and special shield driver circuitry Ignore conductive material buildup on the level sensing element surface, providing reliable point level detection.
The 13L"s explosionproof enclosure and intrinsically safe level probe permit this system to be used in hazardous areas. FM and CSA explosionproofsys tem certification is pending. With its extremely rugged level probe, rated to 232°C(450° F).the system can be used in a wide variety of applications. Also, the probe's stainless steel and Teflon con struction permits use in highly corrosive media. Great Lakes Instruments
For more information,
Circle reply card No. 181
Portable
shallow well sampler
Environmental Management Consultants for Water and Pollution Control Projects Tel.
Fax.
Brampton (416)459-4780 (416)459-7869 Kitchener (519)743-6111 (519) 743-3330
Cobalt
(705) 679-5979 (705) 679-5750
Ideal for purging shallow monitoring wells, the Model 5750 shallow well sam
pler from GEOGUARD. may also be utilized for cleaning GEOGUARD bladder pumps and tubing assemblies, or for any small volume pumping ap plications.
Consultants Limited Consulting Engineers, Pianners, Landscape Architects 220 Advance Boulevard, Brampton, Ontario L6T 4J5
1^ FOMAINE,CDWIE,BUB^TTO St/lSaCIATES UMITED Consulting Engineers
Windsor, Ontario
WATER TREATMENT AND DISTRIBUTION • ENVIRONMENTAL ASSESSMENTS WASTEWATER COLLECTION AND TREATMENT • STORMWATER DRAINAGE LAND DEVELOPMENT • ROADS AND BRIDGES • STRUCTURAL INVESTIGATIONS INFRASTRUCTURE STUDIES • MECHANICAL AND ELECTRICALSYSTEMS 3260 DEVON DRIVE, WINDSOR,ONTARIO, N8X 4L4 (519) 966-2250 FAX:(519) 966-5523
BRANCH OFFICE-WOODSTOCK
(519) 539-2015
The shallow well sampler is a port able. peristaltic pump with a 26 ft. lift which produces flow by squeezing a flexible %" ID silicone tube. The medi
cal grade silicone tubing is the only pump component that comes in contact with the liquid. The user can pump in forward or reverse as well as vary the
MacVIro Consultants Inc. 7270 Woodbine Avenue. Third Floor • Markham, Ontario. L3R 4B9 • Telephone:(416) 475-7270 • TeleFAX;(416) 475-5994
Consulting Engineers, Planners and Scientists, Specializing In the Environment
•Hydrogeology
available. GEOGUARD
•Waste management
MALROZ ENVIRONMENTAL ENGINEERING
pumping rate with an adjustable motor speed controller. The unit is contained in a rugged ABS housing with an aluminum chassis, operating from a 6 Amp-hour. 12 VDC rechargeable gel cell battery; 115 VAC/ 12 VDC power converter; or 12 VDC power cords for connection to a car bat tery or lighter socket. An AC model (5751)for stationary applications Is also For more information,
•Engineering geology
Circle reply card No. 182
•Environmental audits MALROZ Engineering Inc. 168 Montreal St., Kingston, Ont. K7K 3G4 Tel:(613)548-3446 Fax:(613)548-7975
•Site decommissioning & rehabilltatlDn
Clamp-On Flowmeter Clamp-On Flowmeter System 990N from Controiotron is ideal for upgrade
and retrofit applications as it requires 54
Environmental Science c£ Engineering. March 1993
Marshall Mackiin Monaghan Limited
Product Review
i
no process or flow shutdown for instal lation andean be installed in minutes — often with the old flowmeter left in-line.
Consulting Engineers Surveyors Planners
Specialists in Environmental Planning and Engineering. Hydrogeoiogy, Waste Management and Water Resources
System 990N requires very little main tenance. since the flowmeter is com
pletely non-intrusive and there are no
TORONTO, EDMONTON
moving or exposed parts to wear or he damaged by the flow stream.The paten ted MultiPulse measurement technique is entirely digital, and calibration ac curacy will not degrade over time. Sys
Burlington, Mississauga, Whitby
80 Commerce Valley Drive East Thornhill, Ontario L3T 7N4
(416) 882-1100 Fax: (416) 882-0055
Proctor & Redfern Limited
tem 990N uses ultrasonic transit-time
Consulting Engineers Architects Planners
technology.
Environmental Scientists Water Supply, Treatment, and Distribution Wastewater Collection and Treatment
Solid and Hazardous Waste Management Hamilton Kenora Kingston Kitchener London North Bay Ottawa St. Catharines Sault Sie. Marie Sudbury Thunder Bay Windsor
1
45 Green Belt Drive, Don Mills, Ontario M3C 3K3 (416) 445-3600
Fa.x: (416) 445-5276
9^
Stocking costs are minimized be cause System 990N is field programm able for pipe diameters 0.25" to 360". via a simple hand-held keypad. Accuracy is typically within 1% of flow rate over a How range of 1000 to 1. All industry standard outputs are avail able as well as RS-232C computer inter face. Digital, analog and graphics dis plays. with stripchart and datalogger screens, are optional. Controlotron
DDtTD©®© SIMCOE ENGINEERING GROUP LIMITED
Consulting Engineers & Arctiitects WATER SUPPLY • SCADA
For more information,
•
POLLUTION CONTROL •
ARCHITECTURAL SERVICES
•
DRAINAGE ENERGY AUDITS
Circle reply card No. 183
345 Kingston Rood, Pickering, Ontario L1V 1A1 Telephone 416-509-2285 Fox 416-509-1361
Air operated pump control system
TECHNITROL• ECO INC. Environmental Consultants — Laboratory Analysis Industrial Expertise Since 1963 • ENVIRONMENTAL AUDITS • IMPACT STUDIES • RISK ASSESSMENT • WASTE MGMT.
SITE CHARACTERIZATION DECOMMISSIONING
• INDUSTRIAL HYGIENE
PLANT COMPLIANCE AUDITS UST REMOVAL
• STACK SAMPLING • TOXICITY TESTING
• SAMPLING & ANALYSIS
PERMITTING
• MICROBIOLOGY
• AIR QUALITY
121 HYMUS BLVD., POINTE-CLAIRE, QUEBEC H9R 1E6 TEL.(514)697-3273 FAX:(514)697-2090
THORBURN PENNY LTD. Consulting Engineers • Supervisory Control & Data Acquisition Systems • Instrumentation & Controls
Environmental Audits Water Resources Water Pollutlon Control
• Environmental Planning
Water Supply
MILTON: Tel.:(416)875-2144 STONEY CREEK: Tel.:(416)643-8166 OTTAWA: Tel.:(613)247-0111
Environmenial Science & Engineering. March 1993
Fax:(416)875-2145 Fax:(416)643-8171 Fax:(613)247-0114 55
Product Review
Consultants engineers
lyi
Complete Environmental Service
architects
Water Supply • Wastewater • Needs Studies
planners
Environmental Assessment • Environmental Audits
Solid Waste Management • MISA
totten
sims
TEL.(416)668 9363 WHITBY FAX.(416)668 0221
hubicki
environments, and makes installation
COBOURG • TORONTO • KINGSTON • WATERLOO
associates
BRACEBRIDGE • OTTAWA • SAULT STE. MARIE • SIMCOE
TRITON ENGINEERING SERVICES LIMITED
The Diagencx PCTrOOO pump control system aulomaticiiiiy controls and ad justs the air pressure to the feed pump in six individual preset stages oftime and pressure. The time and pressure ol'each stage is fully adjustable. The PCTrOOO comes in a water proof NEMA 4 enclosure to protect the mic roprocessor from the elements in harsh
MUNICIPAL ENVIRONMENTAL TRANSPORTATION WATER RESOUROES
quick and simple. The PChOOO can con
trol any air operated diaphragm feed pump. Internal components are easily accessible for maintenance and adjust ments.
Air or core blow dov\n can also be
automatically conlroiled by the PC60()()
if the filter press is equipped with the proper components. DIagenex
Consulting Engineers
For more information, Circle reply card No. 184
HEAD OFFICE:
ORANGEVILLE • FERGUS • GRAVENHURST • KITCHENER
51 Townline, Orangeville, Ontario L9W IVl Tel:(519)941-0330 Fox:(519)941-1830
Pipe Inspection system
UMA Engineering Ltd. Telephone:(416)238-0007 ENVIRONMENTAL CONSULTANTS & PROJECT MANAGERS
TO GOVERNMENT,INDUSTRY, PRIVATE SECTOR HALIFAX-TORONTOOTTAWA'LONDON-SUDBUHY'WINNIPEQ-REQINA'SASKATOON-LETHBRIDGECALGARY-EDMONTON-BURNABY-WHITEHORSE-YELiOWKNIFE AND THE U.SA
The Versa Trac pipe inspection system
ENVIRONMENTAL NOISE & VIBRATION
consists of: Minilracs. colour CCD
• Measurement, Prediction, Assessment, Expert Testimony • Design and Specification of Control Measures ' Road, Rail & Air Traffic, Manufacturing Plants, industrial Processes, Landfill Sites, Consulting Engineers Quarries, Presses, Blasting 1720 Meyerside Drive, Mississauga, Ontario LS I 1A3 Tel:(416)670-4922, Fax:(416)670-1698 Waterloo (519) 746-3415
camera,onboard light. !()()() feet of conirol cable, power supply, joystick hand controller, powered cable winch, cable counter and camera mounts (for 6"
through 36" pipe). Each minitrac is individually pow ered by a built in motor which provides proportional speed eontroi in both for ward and reverse. To address 6" and H"
pipes the tracks are conllgured nose to WILLMS & SHIER/BARRISTERS & SOLICITORS
tail with the camera mounted in front of
Environmental and Waste Management Approvals.
the lead track. In pipes 10" and larger, the tracks are configured side by side,
Municioal Law. Land Use Planning and Development.
with
4 King Street West. Suite 900, Toronto, Ontario M5H 3X2 (416) 863-0711 Fax:(416)863-1938
the
camera
mounted
between
them.The system can be operated in dry or fiooded pipelines; the complete sys tem is depth rated to !()() feet. Inutstun For more iniormation,
Circle reply card No. 185
Sewer pipe surveying unit XCG Consultants Ltd.
519/741-5774
Suite 904 50 Queen Street N
Kitctrener, Ontario
Fax 519/741-5627
N2H 6P4
Providing Senior Consulting Advice on Environmental Matters Environmental
Engineering Consultants
Richard J. Rush
Stephen G. Nutt
MASc, PEng Principal
MEng,PEng Principal
PUT OUR FORTY YEARS OF EXPERIENCE ON YOUR TEAM
Tlie Model 1512 Pipe Profiling Sonar by Marine Electronics produces high reso lution eotour images of the interior of liquid filled pipes or boreholes. The image produced is effectively a crosssection through the pipe. The .sonar is moved through the pipeeitheron a float (if the pipe is not fully surcharged)or on skids or a conventional wheeled tractor
as used for camera surveys of sewer 56
Enviiviiiuciilal Science & Engineering. March 1993
Product review pipes. The sonar will only work when submerged in liquid unlike a camera system which requires the pipe to be drained before conducting the survey. Accurate quantified data is obtained unlike the subjective interpretation of a conventional camera picture. The images obtained using the sonar may be recorded live using a domestic video recorder in either PAL or NTSC for
mats. Additionally images may be saved to an internal hard disk drive which allows restoration of the full resolution
image at a later date. Hubbard Hume
RS232 data are collected from up to four instruments at a time and brought into the Labtronics Spreadsheet. Routines are then called that will automatically plot Standard Curves, using up to 10 unique standards, perform run correc tions,calculate unknowns,and generate QC Charts. Sample information can be dow nloaded directly from your LIMS and results can be sent directly back.
AAnalyze is a complete, flexible, ready to use package for IBM PCs and com patibles. Labtronics Inc.
For more information, Circle reply card No. 186
Sensors cleaned
For more information,
Circle reply card No. 189
Uninterrupted pipeline flow ensured
automatically
10.26 pH turn canTROL PRntESS
^ra^lD.35 M OUTPUT
The Pipeline Delumper® has been de veloped to eliminate stoppages in pipe lines and clogging of pumps due to solids in the flow. The fluid type pre ssure rate Pipeline Delumper has the full put through capacity of the pipe to which it is connected. It breaks up clus ters, delumps agglomerates and breaks
rugged impeller teeth passing through a heavy bar grating to reduce the size of the product. The machine does not clog because the design uses rugged rotor teeth which completely clear the slots of the bar grating and at the same time clean the entire pipe cross section area. There is very little loss of pressure head.
Heavy and light sludge and slurries, including sewage sludges, are readily processed. Franklin Miller For more Information, Circle reply card No. 188
up globules. It ensures free flow.
The Pipeline Delumper® is an in-line fully enclosed, pipe tight machine oper ating under pressure, vacuum or gravity in liquid, pneumatic or dry systems. Its patented working principle employs
Afterburners oxidize Process Emissions Self-contained afterburners can effi
ciently oxidize a variety ofprocess emis sion gases to help meet air-quality re-
CORROSION PROTECTION SYSTEMS Utilizing an outside water, steam or cleaning solution source, the model
TB701 Analyzer/Controller can be pre programmed to activate the TBl-Bailey Hydraulic Sensor Cleaner for automa tic pH sensor cleaning. Designed to eliminate labour-inten sive manual sensor cleaning, the auto matic cleaner may be used in any submersible installation or when ap plied to a minimum 2 inch NPT backthreaded in-line process. The TB701 can be programmed through an intrinsic cycle timer (0-999 hours) for clean times from 0-999 se conds and recovery times from 0-999
seconds. A "hold outputs (yes/no)" function oversees the cleaning cycle without upsetting recorder and digital outputs. The BID controller automati cally holds its output. The TB701 pH Analyzer/Controller comes with sensor self-diagnostics and multiple control options,including a bi directional controller with adaptable gain, Elsag Bailey For more Information, Circle reply card No. 187
TOC Software
Pipes, flanges, valves and fittings can be buried — but not forgotten. Corrosion will attack, and repairs can be costly. So protect your valuable assets with Densyl Tape and Profiling Mastic. It's long-lasting protection that's easy to apply. • No abrasive blasting • No special equipment or training • Goes on wet or corroded surfaces
• No VOC's, non-toxic
• More cost-effective than paints • Proven long service life • Meets AWWA Standard C21 7-90
for cold-applied petrolatum tapes Call for a literature package. Or, we'll
send a technical representative for an on-site demonstration and analysis of your needs.
AAnalyze is a full featured package for collecting and analyzing TOC data.
LEADERS IN CORROSION PREVENTION
Houston: (713)821-3355 Toronto: (416)940-8255 ©1993 Dense North T^merica Inc.
For more information. Circle reply card No. 130
Environmental Science & Engineering, March 1993
57
Product review gulations. These units are designed and manufactured by Lindberg. A Unit of General Signal. The afterburners help oxidize volatile organic compounds and incinerate process fumes at a pre determined and adjustable temperature
flow volume and transmits a 4-20 mA
signal for use with recorders, indicator and computer equipment. Model IRT provides instantaneous flow rate indication,totalization of flow
volume and transmits a 4-20 mA signal
(from 600 to 2000 F) in an FM/I.R.I.
for communications with recorders, in
approved combustion system. They are pre-piped and wired and have a remov able. wall mount type control panel for separate mounting and easy remote operation. Excess air operation provides the most effective incineration; adjustable air injector and combustion blower with
dicators and like equipment. The unit requires 24 VDC nominal power and has three wiring terminals for easy con nection. This product is unique because it is a fully solid state transmitter at tached directly to the meter for more precise accuracy and long term per formance. Kent Meters, Inc.
filter/silencer further enhance combus
For more information, Circle reply card No. 192
tion efficiencies. Ceramic fibre insula
tion conserves energy through its excep tionally fast heatup and recovery rates. Lindberg
Rate-of-Flow recorder features universal
For more information, Circle reply card No. 191
compatibility
Kent's new IT & IRT
The Meter Master System III. Model 100
Integral Transmitters with 4-20 mA output
Rate-of-Flow Recorder is compatible with all meter types and small enough to fit inside residential meter boxes. The
Kent Meters. Inc.. has developed new integral transmitters with 4-20 mA out put for use with Model C-700 Positive Displacement and Model T-3000 Tur
ompact and portable System III. Model 100 includes a patented magnetic strapon sensor to log the meters magnetic pulse count without any alteration to the
bine cold water meters.
meter. The recorder is submersible and
Model IT provides totalization of
can be secured, if required.
The Model 100 System III Rate-ofFlow Recorder is easy to use and doesn't require a pc at the meter site or in the field. Capable ofstoring up to 20 records prior to downloading, the self-contained recorder interfaces with user friendly system software compatible with gener
ic hardware and disc operating systems. Reports are generated in standard ASCII format for graph generation and export to other database programs. Meter-Master Rate-of-Flow Recor
ders have helped water utilities increase revenues and reduce capital expen ditures. Applications include demand
monitoring, evaluating and proper meter sizing, customer rate structuring, leak detection, resolving customer dis putes and conservation programs. Sensus Technologies For more Information, Circle reply card No. 193
Versatile new leak-tight
Environmental Law
sewer system The Environmental Law Group at Blake, Cassels & Graydon addresses the increasingly complex issues affecting business, municipalities and the environment. The Group provides an extensive range of legal services in all areas of environmental law including: • • • • •
Environmental Assessments & Approvals Environmental Litigation, Prosecutions & Hearings Waste Management & Disposal Transportation & Handling of Dangerous Goods Occupational Health & Safety
• Insurance Claims • Environmental Audits
• Due Diligence (Mergers & Acquisitions) • Sale of Land & Secured Transactions
For more information contact:
With the introduction of its new Boss®
Poly-Tite Gasketed Sewer System. Big "O'Inc. has claimed a first for Canada's
polyethylene pipe industry. The key to the system is its new. gas keted pipe connection. Designed and factory-tested to meet CSA certification standards, the system provides the Bell & Spigot sealed joint required by sani tary sewer systems and those storm sewers needing leak-tight performance. Boss Poly-Tite leak-tight sewer sys tems feature the strength and durability of Big 'O' high density polyethylene (HDPE) pipe. A proven performer in the municipal pipe field. HDPE pipe combines a corrugated exterior for max-
Toronto
Burton H Kellock, Q.C. (416) 863-2400
Schlumberger Industries
John D Brownlie, Q.C. (416) 863-2400
Ottawa
Calgary
Gordon Cameron
Aleck Trawick
(613) 788-2200
(403) 260-9600
Measurement Division
Vancouver
Marvin R V Storrow, Q.C. (604) 631-3300
Introduces new toll free numbers
Phone: I-800-3NE-PTUN(E) 1-800-363-7886
Fax:
Blake,Cassels & Graydon Barristers & Solicitors
I-800-463-METE(R) 1-800-463-6383
Turn-key universal metering programs and Information management systems
For more Information, Circle reply card No. 131 58
Environmental Science & Engineering. March 1993
TURNAROUND TIME (TAT)
Do you know the TAT for your lab? Does your lab know? At EPL, we view TAT as an essential part of our unique approach to quality, service, and capability. We will not only negotiate a realistic TAT with you, we will track it, report it, and meet it.
If accuracy and scheduling are important to you,call EPL. And if you want a TAT report for your projects ail you have to do is ask.
ENVIRONMENT PROTECTION
r LABORATORIES INC.
6850 Goreway Drive, Toronto, L4V IPl, Tel: (416) 673-3255, FAX:(416) 673-7399
For more information, Circle reply card No. 127
Environmental Science & Engineering, March 1993
59
Product review imum strength and resilience with the smooth inner wall required to handle the optimum flow of sewer systems. It is currently available in diameters of 100mm to 375mm. A full range of CSA certified thermoplastic fittings completes the system. Larger pipe dia meters are now being developed, and will be introduced during 1993. For municipal engineers, the system is an excellent choice for either sanitary or storm sewer applications. Since all its components — both HDPE pipe and fittings — meet stringent CSA stan dards, the new leak-tight system pre
al sewer systems. Big 'O' Inc. For more iriformation, Circle reply card No. 194
Balers to reduce volume of domestic solid waste POM balers are suitable for compress ing raw garbage, domestic refuse, and industrial waste. The resulting bales are safe, cost effective and environmentally sound for removal to local landfills.
The baler — designed by COPEX of Erance — operates very simply. Materi al is fed into a hopper and compacted by
sents a viable alternative to convention
a hydraulic piston.The compressed and formed bale is then tied securely with flat bands and ejected for removal to a landfill site. Volume of waste is reduced
by five or six times. The baler's capacity is twelve to forty metric tons of waste per hour, with bales from 5.4 to 12.9 square feet in volume,depending on the model. A special system collects gases and leachates after compaction of the bales. The POM baler is claimed to reduce
X ENVIRONMENTAL PHASE 1 ENVIRONMENTAL PROPERTY ASSESSMENTS
SOIL AND OROUNDWATER INVESTIOATIONS SITE REMEDIATION 6E0L0GYAND HYDROOEOLOGY
[/ SITE DECOMMISSIONING [/ SAMPLE COLLECTION AND LABORATORY ANALYSIS
transportation costs significantly be cause fewer trips are needed to deliver the compacted refuse to landfills. Se curely bound bales are readily stored in a holding area and removed as a group, ensuring full load trips to the landfill. Simple trailers or wagons can be uti lized to transport the bales, instead of more expensive garbage trucks or co vered vehicles. Smaller communities can share the use of a mobile POM
baler, which can readily be moved from place to place. The baler can improve the operating efficiency of landfill sites by stacking bales vertically up to twenty-six feet high,instead of dumping loose refuse in successive layers. Stacking bales en ables operators to handle fifty metric tons of waste per hour,and increases the useful life of the landfill by 20% to 40%. COPEX
[/ GROUNDWATER TREATMENT SYSTEMS
For more information,
Circle reply card No. 195
[/ WASTE AUDITS
[/ OHS,TDG AND WHMIS CONSULTING [/ 100% CANADIAN OWNED AND OPERATED
Ammonia & nitrate monitors Contronic Development's Ammonia Monitor is based on use of an ion-selec tive electrode which measures the con
7900 Canadian Drive
Niagara Falls, Ontario, L2E 6S5 (416) 357-6424 FAX (416) 357-6447
ple by the addition of alkali to convert
•
ammonium ions to ammonia. The in
70 East Beaver Creek Road, Unit 24 Richmond Hill, Ontario, L4B 3B2
strument's microprocessor converts the elctrode output signal to calculate am monia concentration, while compensat ing for the temperature of the sample. The result is displayed as Nitrogen (NH4N). Cancoppas
(416)889-0070
FAX (416)889-0078 •
148 Colonade Road South, Suite 205 Ottawa, Ontario, K2E 7R4
(613) 727-0216
FAX (613) 727-1806
For more information. Circle reply card No. 132 60
centration of ammonia. The principle used involves raising the pH ofthe sam
For more information, Circie repiy card No. 196
Environmental Science & Engineering, March 1993
WE'RE ON TOP OF SLUDGE MANAGEMENT...
46' Floating Sludge Cover, Fergus, Ontario
WITH OUR FIBERGLASS
SLUDGE HOLDING TANK COVERS The corrosion resistant solution for odour control.
Engineered covers designed to meet your project needs.
CANBAR INC.
canbar
Expect the best...since 1872 Box 280, 1 CanbarSt, Waterloo, Ontario, Canada N2J 4A7 Telephone (519) 886-2880, Fax (519)886-5546 Visit our booth at the PCAO Conference for more details For more information, Circle reply card No. 128
Product review New sludge dewatering system good for septage
Classifieds
SLUDGE SLU MANAGEMENT
CARBONITE FILTER MEDIA
WE'RE MOVING AS OF FEBRUARY 15, 1993 Our new phone and fax numbers will be: Phone number:(416)878-2800 Fax number:(416) 878-7332
ANTHRACITE FILTER MEDIA
also suppliers of quality filter sands and gravel
Our new mailing address wiil be: P.O. Box 60069
ANTHRAFILTER MEDIA & COAL LTD.
300 North Service Road West
OAKVILLE, Ontario
L6M 3H2
^20 Sharp Rd., R.R,#6, Brantford, Ont. N3T 5H6 Tel: (519) 751-1080 Fax: (519) 751-0617
Our new 24 hour spills response phone number:(416)878-2800
Circle reply card No. 133
Circle reply card No. 134
noMI
about 95% is evacuated and can be di
RIO.
TECHNICAL
rectly introduced into a wastewater
SERVICE
treatment plant without requiring fur
COMPLETE FLOW MEASUREMENT APPLICATION
"MiSA" Spec Appiications Support
temporary & permanent
ther treatment. Valoraction
For more Information, Circle reply card No. 199
• DESIGN • RETROFIT• INSTALLATION • ACCURACY• Flow Meter Calibration
A variety of sludges have been effec tively treated using the DAB Swedish technology,including biological, physi cal and chemical sludges from was tewater treatment plants, sludges from livestock transportation wastewaters, oily refinery sludges, pulp and paper mill green liquor and domestic septage. The system relies on the combined re sults of decantation and filtration using a patented membrane with collection piping to evacuate the water separated from the sludge. For septic tank sludges,the system in cludes a mixing bar screen, a storage reservoir, a sludge pump, a polymer mixing/metering system and the DAB dewatering unit. The filtrate, with its or ganic and solids fraction reduced by
63 Mclntyre Piace Kitchener, Ontario N2R 1G3 (519)748-8024
For more Information, Circle reply card No. 135
New 'high performancelow cost water pollution monitors
SALES • SERVICE • RENTALS
A new range of high performance, low
Environmental Specialists
cost, ion-selective instruments for mon
Wastewater Sampiers Groundwater Sampiing Levei Controi & Flowmetering Plant Air Clean Up
NiylM
Taylor.
Portable Test Equipment: pH, Turbidity Suspended Solids, Og, DO,(Conductivity
INSTRUMENTS LTD.
Known as the EIL8230 Series, these
2495 Haines Road, Mississauga, Ontario L4Y1Y7, Tel (416) 277-0331, Pax (416) 277-2588 For more Information, Circle reply card No. 136 Plant Facilities & Mobile Services
BLASTAL
Blast
Steel Grit
Cleaning
Sandblasting
Protective
Aikyd Enamels Epoxy Coatings
Glass Bead
BLASTAL COATINGS SERVICES INC.
"Leaders In Quality & Performance"
Coatings
Plastic Flame Coating
748-5443
For more information, Circle reply card No. 137 ENWno^
CANDRUM
microprocessor-based instruments comprise models for three types of mon itoring application — ammonia,nitrate and fluoride. They are aimed primarily where anti-pollution programmes call for optimum controi ofthe sewage treat ment process to ensure that discharges comply with strict consent limits and that potable water abstraction facilities are adequately protected.
Zinc Rich
Clarlfiers, Pipe, Tanks, Structural Steel, Concrete, Small Parts 42 Taber Road, Rexdaie Ontario
itoring or controlling sewage treatment and for monitoring river quality, efflu ent discharge and the purity of potable water has been developed by ABB Kent-
Candrum Sells DOT Approved
Advanced features normally associ ated with much more expensive instru ments include automatic two point ca libration, fault diagnostics and an optional serial communications link for remote interrogation and modification by a PC or main frame computer. As well as providing low-cost access to State-of-the-art pollution monitoring
Drums To The
Waste Handling Industry. Always In stock and ready to ship are thousands of open and closed top plastic and steel drums for new product or waste. Drum disposal available and approved by the M.O.E. Fast delivery always available. Free Brochure Call 416-841-8160 or 1-800-668-3786 Serving Ontario and Quebec
technology, the EIL8230 Series ionselective monitors incorporate several features for minimizing maintenance, thereby reducing the overall cost of ownership. ABB Kent Taylor For more Information, Circle reply card No. 197
For more Information, Circle reply card No. 138 62
Environmental Science & Engineering. March 1993
Analytical labs
Photo report by Tom Davey
Laboratories fight back with the formation of lAETL Canada hundred members expected in the near future. The Canadian chapter expects a similar rate of growth. lAETL has many roles where it strives to improve the state-of-the-art; it also plays a strong advocacy role in articulat ing the collective interests to Congress, state and federal regulators. With the advent of government 'fee for service" from government labs and other incur sions into the domain of private sector laboratories, a Canadian Chapter of lAETL clearly could fulfil a vital role as a militant voice for private sector labs. The meeting was not without its light
Chair
Douglas Langley President, Environment Protection Laboratories, Toronto, Ont.
Laboratories from the private sector
demonstrated
nation
wide support at the founding meeting of the Canadian Chap ter of the International Association of
Environmental Testing Laboratories (lAETL).
er moments. When the interim board was introduced it was noted with sur
Treasurer Bill Neaves
prised good humour that at least three of the members of the board had gained their degrees or were connected with Dalhousie University: including Doug las Langley, President, Environment
Manager, Enviroclean, London, Ont,
"Credible laboratory data is one of the
Protection Laboratories, Bill Neaves,
cornerstones of environmental deci
Manager of Enviroclean, London, Ont. and Dr. Ross McCurdy, Fenwick
sion-making. That credibility is the re sult of combining standardization of methods, careful control of the analyti cal process, and accountability of the laboratory to the data user. In Canada the data user is virtually unprotected, with little chance of assessing objec tively the quality of information gener ated by any laboratory. Accredited commercial labs whose competence has been assessed through a nationally re cognized program will go a long way toward providing that protection. "For many types of goods and ser
Laboratories, Halifax NS.
Astonishingly, the first meeting drew attendees from Atlantic Canada to the
Pacific at the inaugural meeting in Brampton. Ontario, delighting the meeting's chair, Doug Langley. When he called for a motion from the floor which
would allow the present interim execu tive to continue until elections could be
carried out,the motion was unanimous
ly carried. lAETL was formed on January 20, 1988 when it was incorporated in the state of Virginia. The first annual con ference later that year attracted 70 regis trants. That it was a great success was shown by the fact that the 1989 con ference doubled its registration. Mem bership is growing steadily with several
Douglas Langley spoke forcefully when he outlined the steps taken. He said he firmly believed that lAETL Canada would create an economically stronger environmental testing industry through an improvement in the quality of data generated."A strong economic base will also enhance the industry's international competitiveness," he stressed.
He outlined projected membership benefits including the development of industry benchmarks, standard con tracts, errors and omissions insurance, reduction of accreditation costs and va rious discounts for lAETL members.
he said. In his address. Bill Neaves said that:
vices, Canadians have been served well
by the Standards Council of Canada and the National Standards System. This network of accredited Testing,Cer tification and Standards Writing Orga-
His vigorous call for mandatory nation al and international accreditation was
continued overleaf
clearly appreciated by the applause it generated. Dr, Barry Loescher said
having
worked on both sides of the fence, he
was convinced that the private sector could do work equally well, yet at sub stantially less real costs than govern ment laboratories. At the same time,the
President
Dr. Barry Loescher, President, Zenon Laboratories Burlington, Ont.
increased private sector work would promote and strengthen the com petitiveness of a high-tech Canadian industry sector, namely laboratories. "The recent Ontario government ini tiative of charging back municipalities for work done was an unfortunate step in the wrong direction. The MOE fee schedule was blatantly commercial and the unrealistically low prices would serve as a benchmark to "further dep ress pricing in our beleagured industry,"
Environmental Science & Engineering, March 1993
Board member
Alan Maynard Senior Partner, Analytical Services Laboratories, Vancouver, B.C. 63
MME IN CMUDA 'T.C.* waterworks products are100% Canadian-made V
CANADIAN LABOUR-1992 PAYROLL OF OVER $4 MILLION CANADIAN DESIGNED FOR CANADIAN CONDITIONS
CANADIAN MATERIAL PURCHASES-OVER $2.5 MILLION IN 1992 i.'. 'KC'S''. ^
TpANADIAN iANUFACTURING SKILLS & TECHNOLOGY CANADIAN PLANT FACILITIES & ENGINEERING STAFF CANADIAN PRODUCTS THAT MEET OR EXCEED
^.W.W.A. STANDARDS CANADIAN FULL FACTORY BACK-UP SERVICE CANADIAN TAXPAYER-EMPLOYEES
Why is it so important to buy Canadian waterworks products? At Terminal City we believe that Canadian water should flow through Canadian products in order to maintain Canadian payrolls throughout industry. Buy Canadian and support the good life...it's your standard of living. i1
TYTON
DITYT^ C153-88.
4INCH-16INCH
GATE VALVE
\
TC-C71P
COMPRESSION FIRE HYDRANT
TC-20P SLIDE GATE
FIRE HYDRANT
Make the Right Connection...CALL
I
*7etUHC*uU
IRON WORKS LTD.
Manufacturers of Waterworks Fittings, Gate Valves and Fire Hydrants
1909 Franklin Street,Vancouver,B.C.V5L1R1 • Phone(604)253-7525 • FAX(604)253-6365 For more information, Circle reply card No. 129 64
Environmental Science & Engineering. March 1993
Industrial process
By Terry Innes*
Toxicity monitoring using on-iine respirometry The use of on-line respirometry for tox icity monitoring of the influent to the wastewater treatment plant at the Polysar Rubber Corporation Sarnia Ont. Manufacturing Plant was initiated from
the very beginning of treatment plant start-up in 1982. Over the past 10 years the on-line respirometer has assisted in preventing plant shutdowns and in maintaining the health of the micro organisms. The Polysar Biox Wastewater Treat ment Plant is an extended aeration type of biological treatment,and has an aver age inlluent How of 5 MGD. The plant includes the following processes: pH adjustment, oil-water separation, preaeration. aeration and final clarification.
Because of the number of units, and
the variety of chemicals in the influent, the Biox unit needed some sort of pro tection from toxic overload kill of the
microorganisms. Besides requiring an immediate warning of any unfavorable conditions which could prove toxic to the microorganisms, the operators also needed to know the potential health of the bacterial system under normal oper ating conditions. Polysar decided on a combination of an on-line Total Oraan-
Laboratories fight back nizations is recognized internationally, both as a member of the International
Organization forStandardization(ISO) and as a model of industry and govern
ment working together to ensure the quality and safety of products and ser vices in the marketplace. As a result, the CSA label is recognized throughout North America as a synonym for safety in consumer products while the Warnock Hersey certification label on con struction materials can be found in
nearly every commercial building in Canada.
"Ultimately,the public interest will be served best if all environmental mon
itoring data is generated within the National Standards System. The CAEAL (Canadian Association of En vironmental Analytical Laboratories) certification program is an important
first step in that direction. Through lAETL, commercial labs can work to
gether to help complete the process and ensure that the industry is effective in
providing the public with the credible information it needs." he concluded.
With nation-wide representation at its first meeting, it is clear that lAETL Canada has a bright future. For more information, Circle reply card No. 245
Instrument Mechanic Terry Innes checks the refilling cycle of the on-line respirometer manufactured by Arthur Technology and represented in Canada by Quontime Inc. ic Carbon (TOC) analyzer and an on line respirometer. The TOC analyzer works very well for reporting when the plant is getting a high organic loading, but it does not reflect the effect on the plant micro organisms. To monitor the potential "health" of the system, an on-line respirometer is used. The respirometer helps to deter mine whether the influent streams are a
good food source for the mic roorganisms.or toxic. The respirometer is fed a proportional mixture of Return Activated Sludge(RAS) and raw influ ent to form a Mixed Liquor Volatile Sus pended Solids (MLVSS) concentration that simulates upstream the conditions in the aeration tanks. The adjustable
cycle time of the respirometer is set on a twenty-minute cycle, so that each res piration test is twenty minutes in length. The respirometer pumps unfiltered sample automatically from the up stream seed tank into its 4-litre test
will happen in 3 or 4 hours in the aera tion tanks.
Under normal operating conditions, with a healthy bacterial system, and a good, non toxic food source,the respira tion rate is about 45 ml/I/hr.
When a slow increase in organics ap pears. the respiration rate will drop off slightly, then return to normal, even with extended periods of high organics. because the plant microorganisms will acclimatize themselves to the higher or ganic loading. This is one reason Poly sar feels that a TOC analyzer alone is not informative enough for their use. There can still be healthy "bugs" even with
elevated
TOC.
If
the
mic
roorganisms are not suddenly "shoc ked" with high toxics and organic load ings. and as long as the respiration rate remains around 45 ml/l/hr.operators at Polysar know they have a healthy sys tem. Thus far. the on-line respirometer has detected spills of toxins and periods of abnormal pH. When this happens, samples are collected to determine poss ible cause. A toxic kill would require replacement of the plant's mic roorganisms â&#x20AC;&#x201D; a very costly process,
chamber, where the sample is tested. The instrument then discharges the sample, rinses itself, prints out the re sults and prepares to receive another sample. The test is repeated on fresh and one which would also involve shut samples every twenty minutes through ting down the wastewater treatment out the day. The output of the on-line plant for at least a month. respirometer is fed to a computer in a control room for analysis. Changes of *Waste Operations Dept. Polysar principal interest are low respiration rates, which would indicate toxicity. By Rubber Corporation, Sarnia, Ont. testing upstream a proportional mixture of RAS and raw influent, the res
pirometer tells the operator"now" what
For more information, Circle reply card No. 201 64A
Drinking water
A review of government and private labs â&#x20AC;&#x201D; legislation and data quality
Ontario'sDrinking WaterSur
veillance Program, which began in the mid-80"s. is showing sig'ns of wear and tear. DWSP was initiated in response to growing public demand for readily ac cessible information on the quality of Ontario's drinking water. The program met these requirements in the form of annual reports on drinking water qua lity at many locations around the pro vince. However, the reports have become increasingly difficult to inter pret.and the real value ofthese reports is seriously diminished because the public at large, and the media, are simply una ble to interpret the data. This is pri marily due to the number of qualifying statements that the Ministry makes in discussing the levels of chemicals that
The 1990 DWSP reports make little effort to translate the data into language that the lay public can easily under stand.Instead,confusing data qualifiers are used, and a bewildering array of ab breviations and acronyms lace the re
is clear that this(T style of reporting is inconsistently applied within MOE's different laboratories.
leased toward the end of 1992. There are
numbers reported for municipal tap
two general problems with these reports. First, the data is presented in a confus ing. often obfuscating manner.
detection limit and should not be obfus
Second,the data is often not generally being acted upon. For example. King ston has significant detections of ben zene. toluene, ethylbenzene. and styrene in its treated drinking water. The report explains these by saying "the detection of benzene, ethylbenzene. toluene, and xylene. at low trace levels may be a la boratory artifact derived from the analy tical methodology". Well â&#x20AC;&#x201D; it may be. and it may not be. Is it sufficient to sim ply shrug it off as a lab error? If it is a lab error, why was it reported? Is it time that MOE reviewed its QA/QC and report ing methodology? What if benzene and other organic chemicals are present but are mistakenly attributed to "labora tory artifacts"? In another example,desethylatrazine was reported at over 2,500 ng/L in the raw water at Kingston. Rather than ex pressing concern that this pesticide by product would be present in the raw drinking water for one of Ontario's major cities, and rather than try to track
cated by a(T qualifier. Furthermore, it
down the source of this material, the
DWSP finds.
ports. For example,the health guidelines for some chemicals are provided, but the source is unknowable, since the re
ports do not identify a key for the abbreviations used.
Nor do the reports follow a consistent approach in selecting a guideline. Sometimes the guideline will be conser vative, sometimes not.
However,the most puzzling numbers
are those qualified with a "{T". This symbol means"Trace", which is defined in the report as denoting "that the level measured is greater than the lowest level detectable by the method, but lies so close to the detection limit that it cannot he con
DWSP 1990 problems A series of DWSP reports was re
fidently quantified". However, the detec tion limits are sometimes five or six or seven or even ten times lower than the water. These levels are not close to the
Potable water.
Portable plant. Graver Monoplants are pre-engineered and pre-assembled into self-contained water treatnnent units easily transported and quickly installed. Seventeen standard sizes are available to treat from 20
1 :
gpm to 500 gpm,for municipal plants and wherever addi tional or improved water is needed. Each Monoplant contains clarification, filtration, chemical feed and gravity backwash systems. Conservatively designed, the Monoplant pro duces water with an effluent turbidity of less than 1 JTU.
For complete information, contact Ecodyne Ltd., Graver Water Division, Oakville, Ontario, 416/827-9821;
Calgary, Alberta, 403/255-9797
WE MAKE WATER WORK For more information, Circle reply card No. 160 64B
Environmental Science <& Engineering. March 1993
By J.N. Bishop^ report states:"This result was thought to be anomalous by the laboratory analyti
duct off the shelves. Some of them were
cal staff. If it was an anomaly, why was
into local sewers, and yet the levels they
the test not repeated? Why wasn't this result verified? If it is an anomaly, why was it reported? I don't know the an swers to these questions, but I do know that in the private laboratory sector, this would not be an acceptable comment on such a serious analytical outcome. And it should not be acceptable to the people in Kingston, who drink this water. Lindsay's treated water had benzene levels of 1.2 ppb,toluene at 2.4 ppb. and o-xylene at 1.3 ppb.The fact that each of these chemicals are found at the same
time of year consistently in treated and distributed water, but not in raw water, would indicate that the source of con tamination lies within the treatment
plant itself. Municipal staff are "still in vestigating". but the public has no way of knowing whether these chemicals will show up in their water again, or the level they might have to consume, or from what source. Also, since the pro blem results showed up in mid-1990.the
public has every right to know what the investigation showed, and whether they have been consuming benzene and other hazardous chemicals since 1990.
I would also point out that the level of benzene reported for some municipali ties. like the level of toluene, is in the same order that has caused bottled
water manufacturers to pull their pro-
prevented from putting their product were dumping were often lower than the level of benzene or toluene currently
being found in the tap water of cities like Lindsay.
Lindsay also had hexachlorocyclopentadiene reported in treated water and in its distribution system at levels
up to 170 ng/L. While this number is well below the U.S. EPA guideline, it is not much below the New York State
guideline. This underlines one of the basic problems with the DWSP pro gram. namely â&#x20AC;&#x201D; these data should form the basis for instant response from both MOE and the municipalities when such chemicals are reported in the drinking water. These are not small blips mar ginally above a detection limit â&#x20AC;&#x201D; these are major peaks indicating serious con tamination and warranting serious ac tion. They deserve more than just a comparison to the highest available guideline or a scientific shrug of the shoulders, accompanied by the refrain that the result was probably just bad MOE lab data.
Other DWSP problems
The DWSP program consistently re ports significant levels of trihalomethanes (THMs) in treated water in all municipal water supplies. Levels vary, but they are always present and are
sometimes close to 350 ppb in some wa ter supplies. Of course, the Ontario Drinking Water Objective is currently 350 ppb. leaving Ontario and the rest of Canada as the only jurisdictions in the world with guidelines this high for this chemical. Recently, the Ministry of the Environment and Health and Welfare
Canada are said to be moving toward a lower guideline of 50 ppb for THMs. However, it is worth noting that there are many, many drinking water plants in Ontario that do not currently meet this guideline and the question must be asked: is the guideline going to be changed,and if so. will there be changes in the water treatment plants to help these municipalities meet the guide lines? Or will Canada and Ontario's
THM guidelines remain artificially high in order to avoid such expen ditures?
In closing. I believe that DWSP is a very worthwhile, environmentally use ful program. However, the data report
ing needs re-examination.The MOE lab needs to find a more consistent way to
report trace levels, and the Ministry needs to use the data it generates to act upon potential drinking water pro blems. instead of reporting problem data and then questioning the validity of their own data. ES&E
Circle reply card No. 200 *Environment Protection Laboratories
ECODYNE LAMELLA SETTLERS You can't settle for less You can save space and instal lation time when you specify
Ecodyne Lameiia Settlers. Ecodyne's 10 years experience in Lamella Settlers includes
single installations up to 90 MGD, treating a variety of raw waters including Great Lakes water. Graver Water Division
Custom designs are available with plastic or stainless steel plates, galvanized or SS selfsupporting troughs. No field assembly, no maintenance required. You can't settle for less.
We make water work
2201 Speers Road Oakville, Ontario L6L 2X9 Telephone (416)827-9821 Fax (416)827-8428
Other Ecodyne Divisions specialize In cooling towers, evaporators and other process equipment for municipalities, industry, and utilities across North America. For more Information, Circle reply card No. 161
By G. Scott, M..Sc., P.Eng.*
Leachate treatment
Cobourg finds landfill leachate solution A leachate treatment system is now un der construction in the Town of Co
bourg, Ont. which promises to solve a long-standingdifficulty for many ofOn tario's municipal pollution control plants. Cobourg was one of five municipali ties selected by the Ontario Ministry of the Environment(MOE)to participate in the Municipal-Industrial Strategy for
FIGURE 1 FEED AND EFFLUENT COD (mg/L)
/I 16
14
Abatement(MISA) Sewer Use Control
Demonstration Project. Extensive sampling and analyses were carried out at both of the Town's Water Pollution Control Plants
(WPCPs). An industrial monitoring program was conducted as part of the study. Eighteen industrial discharges were monitored, including landfill leachate which is hauled by tanker truck to the Lucas Point WPCP from the
Town's Sanitary Landfill Site. A number of violations with respect to the current Cobourg Sewer Use By-law and pro posed Model Sewer Use By-law were confirmed. Most importantly, the land fill leachate was identified as a dis
charge which did not meet the sewer use by-laws and also as a discharge likely to have a significant impact on the stabi lity of WPCP operation. The Lucas Point WPCP is a conven
tional activated sludge plant with a ca pacity of 5,865 mVd. The plant consists of a single primary clarifier, aeration tank and secondary clarifier. The plant will be expanded to double this capacity in 1993 with the addition of duplicate primary and secondary treatment units.
Leachate Quantities and Strengths The volume of leachate delivered to
the WPCP is weather dependent, exhi biting high peaking factors.The average daily flows over the last 5 years range from 7.0 mVd to 362.6 mVd with an an
nual average of 26.8 mVd. Leachate is hauled to the 'WPCP when the 150 m'
holding tanks at the landfill are full. This increases the impact on the plant due to the shock loading effect. The BOD;(Biochemical Oxygen De mand)concentration in the leachate is high and typically varies between 4,500 mg/L during the wet spring period and 8,000 mg/L during the drier fall period. BOD; values of up to 20,000 mg/L have been recorded, indicating that leachate strength can vary greatly. TSS and Phe nol concentrations are also high and in excess of municipal by-law limits. Simi larly,TKN and NH;concentrations are greatly above desirable levels. *Totten Sims Hubicki Associates 64D
12-
J v 10-1 "a •§
a i 8.
§ ^ 66u ^ 4-
2-
OH 0
5
10
15
20
25
30
PROJECTDAY
Leachate Pretreatment Studies
As a result of the MISA monitoring program, a study was commissioned in 1990 to determine the impact of the leachate on the Lucas Point WPCP.
XCG Consultants Limited were engaged by TSH to conduct this study which was completed in May 1991. The study indi
cated that the BOD;of the leachate was predominantly soluble and likely to impose a high organic load on the aera tion tank. Frequently, BOD; loadings exceeded the aeration tank design capa city. In addition, the leachate exerted a high ammonia loading on the plant,
averaging 800 mg/L. Despite the fact the
c/»x
6C
addition to testing the SBR alternative it was decided to test a Rotating Biological Contactor (RBC) unit in parallel with the SBR.
As a first step in the study, leachate toxicity testing was conducted by mea suring respiration rates of leachate spiked MLSS (Mixed Liquor Suspen ded Solids). These confirmed the lea chate was not toxic.
Three 570 litre SBR reactor tanks
were operated in parallel. The tanks were batch fed from a common leachate
holding tank. Air was supplied from the WPCP blower to a coarse bubble diffuser in each tank. A sub-surface de
canting mechanism allowed decanting without withdrawal of floating scum. A impacting significantly on the plant and 24 hour cycle offeed: aerate:settle: decant jeopardizing operational stability. was maintained. Control was provided "The XCG study also considered me using a PLC. thods of pre-treating the leachate and The SBR study was divided into two recommended biological treatment us phases. In Phase I, the three SBR units ing Sequencing Batch Reactor (SBR) were operated at 10,000 mg/L MLSS and technology designed to bring the leach Food to Microorganism (F:M)ratios of ate strength within the Town ofCobourg 0.2,0.1 and 0.05. The units were allowed Sewer Use By-Law Limits. The report to reach equilibrium and then run for recommended a full pilot plant treata- one month. This phase determined that bility study be carried out to define the the optimum F:M ratio was 0.1. design parameters for the SBR. The During Phase II the optimum F:M Town accepted the recommendations of ratio of 0.1 was maintained in the three this study and decided to proceed with SBR's and the units were operated at the pilot plant study. 15,000, 10,000 and 5,000 mg/L MLSS. Due to the general lack of experience After establishing equilibrium the units with biological treatment of leachate in were run for two weeks. The Phase II results suggested an MLSS of 10,000 mg/L Ontario, the Ministry of the Environ ment expressed an interest in the Pilot as optimum. Plant Study and agreed to co-fund the The SBR's performed extremely well, achieving COD(Chemical Oxygen De study with the Town. Rupke and Associ ates Ltd, were engaged by TSH to carry mand) removal rates of 95% and amouttheon-sitepilotstudy inJuly 1991.In continued overleaf WPCP continued to meet its effluent
limits it was considered the leachate was
Environmental Science & Ettgineering, March 1993
Landfill leachate cont. monia removal rates of 99%. Full ef
fluent analyses confirmed that the SBR could readily achieve the desired results and pretreat the leachate to meet the sewer use by-law limits. A solids produc tion rate of0.6 grams solids per gram of BOD5 removed was predicted.The units experienced a foaming problem which will be mitigated using a defoaming agent in the full scale plant. Since the leachate was found to be phosphorus
to providing the process flexibility ne cessary for treatment of the highly vari able leachate. The end result of the
process is a design which solves the pro blem of leachate treatment for Cobourg and improves the operation ofthe Lucas Point WPCP.
SBR technology is an extremely flex ible process and allows maximum con trol over the treatment cycle. This cou
pled with the 'batch" type delivery of leachate to the plant makes the SBR process uniquely suited for this appli cation.
The design of the full scale unit is complete and construction is about to start. The unit is expected to be on-
stream by late 1993 and the project is seen as an exciting development in the field of leachate treatment.
deficient, phosphorus was added to pre
WATER TREATMENT &
vent the reaction from becoming limited due to this factor. The full scale unit will
use phosphoric acid to maintain ade quate phosphorus levels. The RBC portion of the study in volved the use of a single 46.5 m^ fourstage pilot scale RBC unit. The RBC
CONTROL EQUIPMENT VALVES • METERS • CONTRaLS • SYSTEMS
unit was fed from the same leachate
CLAYTON
VAL-MATIC
VAL-MATIC
CONTROL VALVES
AIR VALVES
CHECK VALVES
storage tank as the SBR's and also con trolled using the PLC. The RBC results were not as promis ing as those from the SBR. The RBC unit was slower to start which would
make it less adaptable to the seasonal variation in inflow ofleachate. The unit was also unable to achieve nitrifica tion.
MILWAUKEE
PRATT
WAFER STYLE BUTTERFLY VALVES
AWWA BUnERFLY
Based on the success ofthe pilot plant study the Town decided to proceed with design of a full scale SBR unit for lea chate pre-treatment.
VALVES
Design of Sequencing Batch Reactor Technology for Landfill Leachate Pre-treatment
Landfill leachate presents quite a challenge for any biological treatment process. Highly variable flows and BOD5 strengths, high ammonia levels and low temperatures(during peak win ter and spring flow conditions)are by no
WATER SPECIALTIES
ENDRESS + HAUSER
METERS
PROPELLER & TURBINE FLOW METERS
MAGNETIC FLOW METERS
WATER TREATMENT
PRV STATIONS
WASTE WATER TREATMENT
NUSGNiCS ULTRASONIC FLOW
means characteristics of an ideal feed stock,
SBR technology has been suc cessfully applied to leachate treatment in the past and several other plants are currently in the design stage following successful pilot plant studies. Neverthe less. experience with operating SBR fa cilities for leachate treatment is limited.
Accordingly, during final design of the SBR.a great deal of attention was given
Toxic shock syndrome The biggest polluter in the US is the military's "toxic empire" — more than
[13@[a]
20.000 sites contaminated with millions of tons of toxins and hazardous chemi
cals. according to recent reports. Of the 20.000 reported contaminated sites on U.S. Defence Department land, only 404 have been cleaned up. The Pentagon produces well over a ton of toxic waste every minute — an output rivalling that of the top five U.S. chemical companies combined, says the magazine Mother Jones.
BCA INDUSTRIAL CONTROLS LIMITED HEAD OFFICE: 9688-187TH ST., SURREY, B.C., CANADA, V4N 3N6 ® (604)888-4141/FAX:(604)888-3565 #5 -6115 4TH ST., S.E., CALGARY, ALBERTA, CANADA,T2H 2H9 lar(403) 253-1949 / FAX:(403) 253-2405
For more Information on the above equipment, please circle the following reader service numbers: Clayton Control Valves (circle 151) Val-Matic Air Valves (circle 152) Val-Matic Check Valves (circle 153) Milwaukee Butterfly Valves (circle 154) Pratt AWWA Butterfly Valves (circle 155)
Water Specialties Flow Meters (circle 157) Endress + Hauser Flow Meters (circle 158) Water Treatment (circle 159) PRV Station (circle 165) Waste Water Treatment(circle 166)
Nusonics Flow Meters (circle 156)
Environmental Science & Engineering, March 1993
65
Guest comment
Media reporting criticized over Ontario Farm Groundwater Quality Survey ment.scientists and professionals in the groundwater industry have been aware of these contamination problems and attempting to find solutions to them
In early November 1992, results of the Ontario Farm Groundwater Quality
sampling of farm water supply wells
luted, tests show.40% on farms unfit for
bacteria contamination of domestic
Perhaps what is most disappointing
use", "Drinking Water Unfit in Many
farm wells and shallow groundwater re sources in agricultural areas is a signifi cant problem that deserves attention. However,this is hardly news as govern-
to our association in the media coverage
(1300 in total)and monitoring wells(144 Survey, funded by Agriculture Canada, in total) installed in adjacent farm were reported on in newspapers across fields. The study confirmed that nitrate and Canada with titles such as "Well pol
Ontario Wells", "One-third of Rural Ontario wells unfit for use",etc. The sur
vey report covered the results of a single
for decades.
of the survey report is the fact that im portant "good news' findings were not given equal billing with the 'bad news' findings. For example, little mention was made of the effective absence of
significant pesticide and herbicide con tamination in groundwater. which is contrary to the general perception that this form of contamination is a wides
pread and serious threat to human health in rural areas.
In our opinion, the survey findings suggest that proper construction prac tices and suitable water well locations .1
are of paramount importance in rural
».
areas. In other words, shallow wells
without casing or seals at surface are at a much greater risk of contamination than deeper drilled wells. Also, well locations near feed lots, manure piles or septic systems should be avoided. The survey results also suggest that agricul tural practices such as fertilizer applica
Kruger
:
tion on farm fields be re-examined as a
step towards protecting a valuable na tural resource.
Groundwater is a safe and economi
Why settle for less?
Introducing the Kruger/Fuchs ATAD system.Your first choice for effective, effi cient and economical sludge treatment. Quality Our Autothermal Thermophllic Aerobic Digestion(ATAD)process has provided
excellent performance w/orldwide. It's recognized by the EPA as a process that can meet the new Part 503sludge regulations for land application of municipal wastewater sludge, which Includes PFRP and Class A requirements.
cal source of water supply for a large number of people in rural areas and will remain so provided it is developed and protected by common sense actions. It is unfortunate that the positive aspects of groundwater are rarely mentioned in the media. We believe that the public should be aware of the occurrence and
benefits of groundwater in Ontario to appreciate and protect this natural re source.
Speed Our ATAD system features a sludge holding time of just six days In most cases.
That's up to 75% less than with other aerobic or anaerobic methods, saving both space and time. And It's easy to operate, which reduces training time and operating personnel.
Well Association
Heavy metal?
Price
Our autothermal process requires no additional heat, providing significant energy savings.The quick digestion cycle uses smaller tanks,further reducing capital costs. No added chemicals or expensive nitrification equipment are needed, either.
Dependable. Fast. Affordable. There's only one choice for sludge treat ment: Kruger/Fuchs ATAD. More than just A TAD better. Licensed from Kruger in Canada and the Pacific N.W. of U.S.A. by
SANITHERM ENGINEERING LIMITED 1385 Crown Street, North Vancouver, B.C. V7J 1G4 Telephone:(604) 986-9168•Telefax:(604)986-5377 For more information, Circle reply card No. 241 66
J. Rennlson, President, Ontario Water
Australia has just launched three pla tinum bullion investment coins — to be known as the Australian Koala — inter
nationally, GoldCorp Australia says. GoldCorp Australia, operator of the mint that makes the coins for the Aus
tralian government, said it will intro duce the legal tender coins, which will contain two ounces, 10 ounces and one
kilogram of platinum. Apart from the mixing of Imperial measures with metric, we wondered if
the "kilogram" was a misprint or if they have sturdier pockets Down Under. Environmental Science & Engineering. March 1993
f•
John Allen, P.Eng.
John Blanchet,P.Eng.
Dave Brierley, P.Eng.
Ken Collicott, P.Eng.
Division Manager,
Division Manager,
Senior Environmental
Ottawa
Victoria
Division Vice President
P
Engineer
mf,
Boh Curtis, P.Eng.
Euan Ferguson,P.Eng.
Naz Hijazi, Ph.D, C.Chem.
Boh Kieley, P.Eng.
Director & Division
Senior Environmental
Chief Chemist &
Manager,
Manager, London
Engineer
Environmental Consultant
St. Johns
Wouldn't you smile too?
ENVIRONMENTAL ENGINEERING DIVISION Brian Lemke,P.Eng.
Andy Liu, P.Eng.
Jim McGregor
Jose Paradela
Senior Environmental
Senior Process
Procurement
Regional Vice President,
Engineer
Engineer
Manager
Latin America
WESTERN CANADA: John Blanchet
Phone:(604)385-8721 Fax:(604)383-8099 EASTERN CANADA:
David Brierley Phone:(416)441-4111 Fax:(416)441-4131
i« Jeff Plant, M.B.A.,P.Eng. Indra Prashad,P.Eng. Division Manager Toronto
Environmental Engineer
Randy Rosin, P.Eng.
Hugh Tracy, P.Eng.
Senior Environmental
Chief Environmental Engineer
Engineer
For more information, Circle reply card No. 242
Kent Can Canada Is Ready For Change And Kent Can Make The Difference... Kent can reduce unaccounted for water Meeting AWWA standards, Kent's C-700 is perhaps the most technologically advanced water meter on the market today. The C-700 meter is a performance proven leader offering accuracy down to 1/8 gpm,
Kent can give you competitive water meter prices Let Kent prove that water meter prices don't have to increase year by year. Check to see if Kent is listed as an approved vendor in your specifications. Kent can
protect your
the best linear
metering future
accuracy and pressure loss of only 6.2 psi at 20
Incorporating state-of-the-art
technology, the highest quality
gpm.
standards and
Kent can streamline
product compat ibility, Kent can show you how "open design
your ordering requirements
architecture" can
With more than 23
protect your
representatives
metering future. Kent also provides the longest and most comprehen sive warranty program in the industry.
from St. Johns to Victoria who maintain stock
locally and are responsive to your individual needs Kent
is able to deliver your water meter orders
efficiently with daily shipments.
Change To Kent For The Future In Water Metering
Mississauga Ontario L4W 2S7 Canada
A 1111 mpip
Phone 416-238-9622 Fax:416-238-5640
ASEA BROWN BOVERI
Kent Meters, Inc. 1200 Aerowood Drive, Unit 35
For more information, Circie reply card No. 205 68
Environmental Science & Engineering, March 1993
ENVIRONMENTAL LABORATORIES INC.
Need the address or phone number ofa consultant, equipment supplier
COMPLETE ENVIRONMENTAL ANALYSIS
or lab, use ES&E's
January Directory issue
TSL is a comprehensive analytical lab certified by CAEAL,the govern ment of B.C. and ACPO.
Eimco Reactor Clarifier
EIMCO
EIMCO Reactor-Clarifier solids con
Reactor-Clariffer
tact units combine chemical addition
and mixing, solids contact fiocculatlon, clarification and sludge removal in a single basin. They provide effi cient removal of suspended solids and are ideal for lime softening. A low speed turbine maintains large vol
WATER•SOIL•INDUSTRIAL WASTE•AIR•OIL
REGULATION 309 DECOMMISSIONING SEWER BYLAWS DRINKING WATER LAKEFILL GUIDELINES MISA GC-MSD SAMPLING EXCESS MATERIAL GUIDELINES
umes of flocculated solids recirculat
ing within the conical reaction well. Influent water and chemicals are In
troduced directly into the recirculation stream, optimizing chemical usage and floe growth. Sludge set tles out and Is collected by a bottom rake whilst clarified water rises up and is collected by a launder
1301 FEWSTER DRIVE
MISSISSAUGA, ONTARIO L4W1A2
(416)625-1544
system. EIMCO
Circle reply card No. 242
T.S.L.*** An environment of Quality and Service For more information, Circle reply card No. 251
Outstanding Waste Reduction Pereormance Awards COMPETITION DEADLINE MAY 30,1993
■ Who is eligible?
■ Judging criteria
Organizations which have reduced hazardous or liquid
A panel of five waste management experts representing industry, government, education and the media will evaluate the applications. Entries will be evaluated on: • Quantity and toxicity of waste reduced, reused or recycled • Environmental benefits and cost savings • Evidence of involvement by both management and line personnel • Situation complexity and innovation employed • Applicability of the method to other companies
industrial waste are eligible.
Winning this award will demonstrate to employees, customers, shareholders and the local community that your
company is committed to protecting the environment. All companies in Ontario that have reduced large or small quantities of hazardous or liquid industrial waste since January 1, 1986 are encouraged to apply. There will be one overall winner and additional awards of merit.
■ Award presentation
•W
Awards will be presented by the Minister of Environment at the Technology Transfer Conference. Employees who contributed to the program will be recognized.
Chrysler Canada's Windsor Assembly
■ For further Information
Plant won the
1992 award. OWMC
Mr. R. F. Nowina,
president, Donald Chant (left) presents award to plant environmental
Ontario Waste Management Corporation 2 Bloor St. W., 11" Floor Toronto, Ontario M4W 3E2
co-ordinator Sue
Tel:(416) 923-2918
Forest and Chrysler
Or call toll-free: 1-800-268-1178
e.xecutive R. A.
Renaud.
©WAAC HAZARDOUS WASTE REDUCTION AND TREATMENT SPECIALISTS
For more Information, Circle reply card No. 252
Environmental Science & Engineering. March 1993
71
[NVimiNii! PfflKINfi We're SSCAN-GRODYNE, with many
years of experience in providing industry with analytical and environmental measurement packages— from portable instruments to elaborate systems — permanent or mobile configurations.
Whether your requirements are for continuous emission monitoring, ambient air or water ,v
quality, we have the proficiency to recommend, design, and provide the start-up and commissioning of your project.
•' I
In addition, SSCAN-GRODYNE supplies only the finest, quality-built instrumentation. To
-• - "-fi'.j'- [gi ' '*-'
i
''•!
you, this means maximum system up time,
T"'*> '»*'•
»
•
-• •.'
J'"
■ '■■ '
superior product performance and lower cost
of ownership. Brand names include HORIBA, environnement SA, KURZ, PANAMETRICS, NOVALYNX.
So the next time you have a need for monitoring expertise, SSCAN-GRODYNE can
be quite instrumental to the efficiency and co.st-effectiveness of your installation. Call us
for full information on our products and systems -5- available nationally.
m
SSCAN-GRODYNE
7222 Flint Place S.E., Calgary, AB T2H 1Y8 Phone: (403) 253-2241 Fax: (403) 253-2275
0 m
•
.
11
BRANCHES ACROSS CANADA
r
For more information, Circie repiy card No. 253 72
Environmental Science & Engineering, March 1993
COMPLIANCE SOLUTIONS THAT PAY BY
AER-O-FLO ENVIRONMENTAL THE 4 R's • 98% Solids Reduction • 98% FOGs
,V^r^
Reduction
• 80% BOD5
jQ-f 'f -
Reduction
• $ Cost
„ 1
Utilizing the Aer-O-Flo fully automatic Chemfloat system, food processors across Canada are experiencing dra matic reductions in solids, fats, oils, greases (FOGs), BODs and costs. The PLC controlled, low maintenance, com pletely stainless steel process is easy to install.
Reduction
compact and operator friendly. It will treat your waste for dimes not dollars.
This low retention time, non-biological process is another guaranteed solution by Aer-0-Flo Environmental, where our product is your satisfaction.
Aer-0-Flo — your environmental solution company
Aer-0-Flo Drumshear
Aer-O-Float
The Proof
Fine Rotating Screen
Flotation System
& The Pudding
1TPSSS
T SSE
Circle reply card No. 143
Circle reply card No. 144
Circle reply card No. 145
AER-O-FLO ENVIRONMENTAL INC.
Your environmental solution company 1175 Appleby Line, Unit B2, Burlington, Ontario L7L 5H9 Tel:(416)335-8944, Fax:(416)335-8972
For more information, Circle reply card No. 146
Report from the Third Int. Zebra Mussel Conference Combined use of heat and oxidants for controlling Zebra Mussels The objective of the research was to examine the combined use of heat and
chemical oxidants for controlling zebra mussels in power plants. Previous re search has shown that either chemical
oxidants or high temperatures are lethal to zebra mussels. Heat treatment is an
effective control option for power plants, but in some portions of power plants water can not be raised to lethal
temperatures for zebra mussels(e.g.,ser vice water systems). Studies were conducted at an Erie
County Water Authority's Raw Water Pump Station located along the Niagara
Donald K. Harrington, John Van Benschoten, James N. Jensen, and Thomas Brady, University at Buffalo; Don Lewis, John Sferazza, Aquatic Sciences Inc; Edward Neuhauser, Niagara Mohawk.
from the acclimation temperature to the desired exposure temperature over a period of approximately one hour. Oxi dants were introduced at the beginning of an experiment(chlorine) or approx imately 15 minutes prior to reaching the desired exposure temperature (ozone). Sampling(n = 10 mussels per replicate) was performed at defined intervals and
River in the Town of Tonawanda, New
mussel mortality was determined by vis
York. The addition of oxidants (chlo rine and ozone) at various concen
ible gaping and unresponsiveness to gentle probing roughly 48 hours after
trations (chlorine at 0.5 and 0.1 mg/L sampling. Study results showed that the com and ozone at 0.5 mg/L) were examined at elevated temperatures (25, 30, 32, 34, bined use of heat and oxidants can be and 36°C). Control experiments were more effective than either treatment alone. For example, mussels acclimated conducted using heat alone. The influ ence of acclimation temperature (0-5, to 0-5°C and exposed solely to 32°C 10-15, and 20-25°C) also was studied. required 11.4 hours to obtain 95 percent mortality. For the same temperature Experiments were conducted using Nia gara River water and continuous flow conditions but with 0.5 mg/L chlorine or stirred tank reactors. Most treatments 0.5 mg/L ozone, 95 percent mortality were run in triplicate with approxi was reached in 3.5 and 3.3 hours,respec mately 100 mussels per replicate reactor. tively. At a given exposure temperature, Water temperatures were increased the effectiveness of the combined use of
heat and oxidants increased with dec
reased acclimation temperature. Lor ex ample. at 32°C and 0.5 mg/L chlorine,95 percent mortality occurred in 3.5 and 5.9 hours for mussels acclimated at 0-5°C
and 20-25°C,respectively. At 36°C, mini mal differences were observed between
mortality due to heat alone and the com bined use ofheat and oxidant,suggesting that at or above 36°C heat treatment alone
is an effective treatment strategy. Laboratory data were compared to data collected from a field scale heat
treatment conducted during September, 1992 at Niagara Mohawk's Dunkirk Steam Generating Station. No oxidants were used during the treatment and mussel mortality was determined at va rious points in the plant. In general, good agreement was observed between laboratory and field scale results. At 3435°C for one hour, field scale treatment
resulted in 50 to 60 percent mortality compared to 40 percent mortality for laboratory experiments. Based on labo ratory studies, 95 percent mortality for the field scale test would have occurred
at 3.1 hr; with the addition of 0.5 mg/L chlorine the time for 95 percent mor tality is estimated at 1.7 hr. Circle reply card No. 249
1
S^pUilLSiUJI They are ail at stake when you select an environmental laboratory. Whether it's wastewater monitoring for AUSA compliance, evaluation of hazardous waste, or a full-scale site investigation
you need a lab that you can depend on to provide reliable data, quickly and cost-effectively.
For more than two decades Enviroclean has earned
a reputation for promptness and reliability as a full-service laboratory serving clients both in government and industry. That reputation has been built on a commitment to quality. Our quality assurance program is designed to ensure that every piece of analytical data is
scientifically correct and can stand up to scrutiny. And we back up that commitment with regular participation in interlaboratory quality assurance programs which test our performance against other labs. We don't claim to
be perfect, but when you choose Enviroclean, you can count on getting our best. Always.
ENVIROCLEAN Environmental Laboratory Services 74
For more Information, Circle reply card No. 150
921 Leathome St.
London, Ontario M5Z 3M7
Phone:(519)686-7558 Fax:(519)686-6374
Environmental Science & Engineering. March 1993
m
FIBRESEP INTERCEPTOR PRODUCTS
Attention Consultants, Plant Engineers, Plumbing Inspectors, Environmental Officials and Contractors!
Fibresep Limited offers a full line of Canadian
made
interception products that are cost effective, chemically inert and easy to install. The products facilitate sani tary sewer and storm sewer applications.
Advantages include : • Compact treatment chamber • No scouring • Easy to clean • Easy to install • Chemically inert
Applications include : • Service Stations
• Grocery Stores • Garages • Fast Food Outlets
• Machine Shops • Wholesale Food Outlets
Applications include :
• Factories • Restaurants
• Street sewers in road
• Fish and Meat Processors
allowances
• Service connections for: • Petroleum service stations • Factories
• Commercial, residential
& industrial parking lots
Interceptors For Sanitary Wastewater Separation The Fibresep line of oil & grease separators are of proven
design, capable of meeting cur rent regulatory requirements and able to accommodate wide variations in waste flow without loss of contents.
Fibresep Limited currently pro duces its products from Fibreglass Reinforced Plastic. In the summer of 1993 raw materials will be converted from
FRP to post-industrial thermo
The Stormceptor System For Stormwater Treatment
Advantages include : • large retention capacity for
The Stormceptor System is a
retained oil & solids
treatment device that removes
and locks up oil spills and sedi
• chemically inert and imperme
plastic using a new and unique manufacturing process. For more information contact:
Fibresep Limited, 2336 Royal Windsor Drive, Oakville, Ontario, L6J 4Z2
able to retained waste
ment in storm sewers at "the
source". The patented "lock up" feature allows for a compactsized treatment reservoir, and
prevents scouring of the trapped contents during periods of heavy stormwater flow.
• light weight for easy handling Telephone:
by contractors
416-338-6388
• cost effective - can be installed
Fax:
in 3 hours
• high strength to withstand below ground pressures
for more information, Circle reply card No. 147
416-338-6420
Fibresep
Industrial solvents
Tougher regulations led to complete systems approach to surface cleaning sign, Dow offers a detailed system speci fication and price quotation package. Having evaluated many major equip ment manufacturers, Dow can make a
recommendation of the best cleaning process for the customer. In the third phase. System Implementation, Dow provides start-up assistance, "system optimization" and on-site training. Fol lowing these steps, ongoing systems support services, including supplies, training, process enhancements and equipment upgrades are offered. Customer Commitment
Dow has also developed the family of
PRIMACLEAN'"surface cleaning pro ducts. Customers are currently using these new aqueous, water rinsable (also known as semi-aqueous) and general cleaning products on trials. Dow also offers the resources of a new state-of-the
art Cleaning Technology Center at its Midland, Michigan headquarters, where cleaning products and equip ment
are
tested
to
find
the
best
solutions.
For more information, Circle reply card No. 248
Announcement
Proposed regulations will require companies to seek alternative technologiesfor their surface cleaning processes.
The Dow Chemical Company has cre ated a new systems approach to help surface cleaners make an efficient tran
sition from 1,1,1-trichloroethane to an
alternative process. The Canadian En vironmental Act(CEPA)and the Mon treal Protocol are accelerating the need
to change to new cleaning products; yet, many companies do not have the re sources to develop alternatives. In addi
drop-in solution to surface cleaning.The only way to solve it is to assist in the onsite development of cleaning specifica tions and system design that is parti cular to each customer. By combining our existing R&D and technical exper tise with the cleaning equipment sup pliers we've created the Advanced Cleaning Systems."
tion, exclusive reliance on internal de
Systems Approach Targets Changing
velopment can be very costly,time con suming and questionably successful.
Environment
Marc Salatino, Dow Canada market
ing manager says: "Environment Ca nada's proposed regulations will require companies to seek alternative technolo gies for their surface cleaning processes. The need for understanding each cus tomer's manufacturing process require ments for surface cleaning is critical. This is radically changing the market ing approach because not all systems are compatible or suitable in all appli cations. There will be no offthe shelf or 76
Advanced Cleaning Systems can pro vide an integrated alternative clean ing system to chlorinated solvents. A service agreement may include the sup ply of equipment, technical services, and cleaning products or a combination of all three. This service approach con sists ofthree phases.In System Develop ment,the first phase,an on-site analysis of the customer's cleaning needs is con ducted. After extensive testing, an opti mum cleaning process is recommended. During the second phase. System De-
CANVIRO Analytical Laboratories Ltd.is pleased to announce that Stan Kolanko, B.Sc., M.B.A., has joined us in the capacity of Marketing Special ist. Stan has over 15 years of pro gressive sales and marketing experi ence in Ontario with a good back
ground in the chemical industry and environmental regulations. With the addition of Stan's knowledge and ex pertise, CANVIRO Labs continues its commitment to providing superior service to current and potential clients.
CANVIRÂŽ For more information, Circle reply card No. 148
Environmental Science & Engineering. March 1993
ilMNN MANN
TESTING
LABORATORIES
r
(416) S90-2555
Customer Service
Air Emissions
Environmental Analysis
Twentieth Anniversary of Quality Results on Time* • Occupational Health and Safety • Air Emissions Effluent Characterization • Soil, Water, Air and Food Residues
Call our Customer Service Department and let ttiem make your life easier! In Ontario Tel. 416-890-2555 Fax. 416-890-0370
In Alberta Tel. 403-462-6575 For more information, Circle reply card No. 149
Certified by CAEAL, CSA, Standards Council of Canada and New York State (ELAP)
Toll Free 1 - 800 - 563 - MANN 5550 McAdam Road Mississauga, ON L4Z IPl
Storage solutions
Tensioned geomembrane floating covers pass test of time for wastewater and potabie water appiications million gallon potable water installa tion serving Fairmont Hot Springs. B.C. where temperatures drop to -30 to -35C. and the lake freezes to 60 centimetres thick.
Two of the firm's largest installations are at the Halton Region sludge tank farm nearToronto and at Fletcher Chal
lenge Canada's Elk Falls paper mill, near Campbell River. B.C. At Halton. floating covers provide protection for some 64,000 cubic metres ofsludge contained in 8 in-ground tanks with operating depths of6.5 metres. The stabilized sludge, generated by seven wastewater treatment plants which pro cess over 40 million imperial gallons daily, is stored in the tanks over winter and spread onto fields during the plant ing months. The floating roofs contain odours, reduce the natural loss of nut rients and eliminate the influx of rain water.
The Fletcher Challenge Canada's Elk Falls paper mill uses a floating cover on a 20,000m^ chemical treatment basin.
With over 30 tensioned geomembrane floating covers in service throughout Canada, the concept for potable water and wastewater storage has passed the test of time. Columbia Geosystems,Ltd. a Calgary-based firm, pioneered the floating cover in the early 70's. Neil McLeod. Columbia Geosystems President says there are installations as large as 20,000 square metres. The com pany's first 1.430 square metre floating cover on a 500.000 gallon in-ground pot able water tank is still in service at
Grand Forks. B.C.and after 18 years has developed no tears or leaks.
The firm's RE'VOC® system is designed for in-ground and tank fluid storage at water utilities, wastewater treatment
plants, pulp and paper mills, pet rochemical and mining operations and food processing. Basically, the cover floats on the sur face of the liquid being stored. As the level moves up and down, so does the cover. A series of perimeter tension ca bles and counter-weights keep the lid flat and prevent it from rotating or shift ing with the wind. Although flexible,the covers — made of 60 to 80 mil low. medium and high density polyethylene and Hypalon — are far from flimsy. Some weigh 30 met78
ric tonnes or more.
Economics is an overriding con sideration in selecting a floating cover. Construction costs are only 10% the cost offixed structures while requiring much less time to complete. They require less maintenance and can withstand severe climatic conditions such as at the 1.2
The Elk Falls floating cover is on a 20.000 square metre chemical effluent treatment basin. The 7.5 metre deep basin is used to smooth out pH swings created by mixing dissolved chlorine and sulphides from the pulping process. The floating cover allows operators to contain odours, particularly hydrogen sulphide. The mill generates some 200.000 cubic metres ofeffluent per day. of which 100.000 pass through the equa lization basin. This mill was featured in the November 1992 ES&E as a cover
story. ES&E
Circle 256
AD INDEX Abb Kent Taylor
70
Deican
67
MOE
47
Ago Assman
40
Dense
57
Monitarlo
62
ADI
69
Ecodyne
Aer-0-Flo Anal. Meas. Anthrafilter
73
Eimco
64b, 64c 71,80
MSU Mississauga 19, 39, 46
69
Eneco
32
National ins.
62
Env. Prot. Labs
59
Neo Valves
69 16c
Aquatic Science
23
Envirociean
74
NRC
Arcturus
60
75
Ont. Sewage Equip.
Asdor
45
Fibresep Fiygt
41
BCA ind
65
FMC
37
OWMC Quontime
BEP
10
Gore & Storrie
13
Robar
Biake Casseis Gray.
58
Gorman Rupp
17
Samuel Pipe
Greatario Groundwater Tech.
46
Sanitherm
11
12
Schiumberger
79
Biastai
Brinkman
62 card
Can. Am. ins.
62
Hach
43
Summa
Can. Ex. Man.
48
Heath Cons.
21
Tech. Serv. Lab
Canbar
61
Humboidt Decant.
Cancoppas
2
Can drum
62
Canviro Labs
76
Capital Petrol Colgate Palm.
16d
16,69
6,7
42 8 71 15 10
card
card 71
Ter. City iron Works
64
62
ind. Env. Supp.
36
Terratech
isco LCI
38
Trimax
69
Vaioraction
22
Magnetroi Mann Testing
39
Victauiic
33
77
Westech
5
9
Environmental Science & Engineering, March 1993
Schlumberger Provides Solutions Schlumberger Neptune® ARB™ System Introduced in 1964,the Neptune® Automatic Reading & Billing Sys tem is the encoder register of choice for over 400 water utilities today.
(I
• Easily mounted to any Neptune® meter,the ARB™ encoder system transmits the actual register reading,in an electronic data format to a remote, accessible location.
• Proven reliability in over 4,000,000 installations throughout North America.
ARB™ suits all applications: • ARB V™ for indoor settings
• ProRead ARB™ for pit installations and large meter vault settings. • ProRead ARB™ for reprogrammable, utility defined metering in formation.
For more information, Circie repiy card No. 236
Schlumberger Reading Systems Schlumberger Industries is dedicated to the development of Meter Reading Systems that will maximize the efficiency of your water utility.
• Neptune® Unigun™ System — specifically designed for data cap ture and management with the ARB™ system. Eliminates routebooks and data entry through a hand held mini-computer and PC based software system.
• Central Meter Reading(CMR™)— Schlumberger offers both Out bound and Inbound telephone based systems for single or multiutilities.
• Introduced ARB™ data transmission through Radio Frequency at the '92 National AWWA Conference in Vancouver.
• Schlumberger guarantees compatibility of ARB™ encoder regis ters with our present and future reading systems. For more information. Circle repiy card No. 237
Schlumberger FloSearch System The FloSearch™ System is designed for profiling customer water usage patterns.
• Applications include leak detection, meter sizing, demand meter ing and peak usage studies.
• The FloSearch™ transmitter and FloSearch™ recorder continuously sample and record usage data. • PC based software generates reports of flow vs. time and water usage vs. flowrate in both graphical and tabular formats. • Usage data files may be exported to word processors, spread sheets, DOS,etc. For more information. Circle reply card No. 238
Schlumberger
-ilumberger Industries
asurement Division — Canada
75 West Credit Ave.
isissauga, Ont.
Regional Sales Offices 1209-59th Ave. S.E., 6555, boul. M6tropolitain est. Suite 140 Suite 402, Calgary, Alberta St-Leonard, Quebec
^ 5M9
T2H 2P6
H1P3H3
6)858-4211
(403) 253-0055
(514) 327-9998
For more Information, Circle reply card No. 239
Technicai Service Group 7275 West Credit Ave.
Mississauga, Ont. L5N 5M9
(416)858-4211
Underdrawis Air + WErter Separate ducts fen air and water and improved orifice sizing are the keys to uniform fiow distribution NEOPRENE
SEAL
AIR HEADER AIR ORIFICE WEEP ORIFICE
ORIFICE SHIELD
AIR DUCT
WATER DUCT WATER ORIFICE
FILTRATE BACKWASH
FLUME PLATE
FLUME CHANNEL
â&#x20AC;˘ Copposion-Resistant
HiM Unifopm Flow DtstpHnitlon ReAiced WastiWatop Use No false Floop
RoquiPed Ideal Retpoflt
The underdrain is the heart of every granular media filter. If the underdrain is well designed, durable and efficient, the filter will provide many years of continuous service. If not, the underdrain, and perhaps the entire filter may require replacement after only a few years use. Flexscour underdrains provide a durable, corrosion-resis tant system for collecting filtered effluent and accurately metering uniform air/water backwash flows. Innovative design features eliminate the two flow problems that have plagued other combined air/water cleaning systems: improper sizing of variable diameter orifices, and media displacement by surging or irregular flows.
^EIMCO Process Equipment A Baker Hughes company 5155 Creekbank Road
Mississauga, Ontario L4W1X2 Tel;(416) 625-6070 / Fax:(416) 625-3519
259 Midpark Way S.E.
4940 Chisholm St. / Ste. 1
Ste. 220
Delta, B.C. V4K 3X2
Calgary, Alberta T2X 1M2 Tel:(403) 256-6812
Tel:(604) 946-0421 Fax:(604) 946-7837
Fax:(403) 256-7071 P.O. Box 300
1 Holiday Street 5th Floor, East Tower Pointe Claire, Que. H9R 5N3 Tel:(514)695-9531 Fax:(514)695-8099
For more information, Circle reply card No. 240
Salt Lake City, Utah 84110 (801) 526-2000 Fax:(801) 526-2005 U.S. Patent #5019259