TECHNICIAN’S HEATING
CATALOG Y O U R S I N G L E S O U R C E F O R H E AT I N G PA R T S
TECHNICIAN’S HEATING CATALOG
AIR QUALITY CHEMICALS ELECTRICAL GRILLS REGISTERS HEATING CONTROLS HYDRONICS/STEAM MOTORS & ACCESSORIES GAS HEATING NOZZLES OIL HEATING PIPE & FITTINGS TESTING EQUIPMENT THERMOSTATS TOOLS VENTING TECHNICAL INFORMATION
To our customers, We are very excited to offer this new catalog for the heating technician. We have tried to put this catalog together in an easy to use format. All items listed have both the manufacturer part number as well as the Webb part number. This makes it easy to go on-line for further information including availability and pricing. In the back, you will find some very “unique” stuff that we have assembled thanks to other organizations and industry experts. The sections on “Troubleshooting”, “Helpful Hints”, and “Test Procedures” are courtesy of Dan Holohan, Carlin and Westwood Products. The Cross Reference Charts came to us from Beckett, Honeywell, Allanson and Taco. Peerless Heating gave us sizing radiation as well as the section on antifreeze. We are grateful for their help. With 295 pages of heating parts and accessories, we trust you will find this catalog useful both in the office and in the service technician’s truck. F.W. Webb has over 70 locations throughout New England and upstate New York and in excess of $100 million dollars of inventory to service your needs. Give us a call today, we think you will be glad you did. Sincerely, Jeff Pope President F.W. Webb Company
Easy Ordering INTERNET! www.fwwebb.com We accept MasterCard, VISA and Business American Express. F.W. Webb is in no way responsible for errors, omissions or typos in the Heating Catalog. Furthermore, the pictures, ads and editorials contained in the Heating Catalog are copyrighted and cannot be used in full or any part without express permission of the publisher.
IFC.indd 1
3/24/08 12:33:30 PM
F.W. Webb Company
HEATING EQUIPMENT
F.W. Webb Company is the Northeast’s leading distributor of these premier heating equipment manufacturers.
First Co. Smith
logo page.indd 1
4/8/08 8:45:30 PM
F.W. Webb Company
TECHNICIAN’S HEATING CATALOG Table of Contents Section 1 2 3 4
5
6
7 8
Page Air Quality
1
Chemicals
10
Electrical
16
Grills/Registers
19
Heating Controls
25
Hydronics/Steam
41
Motors & Accessories
84
Gas Heating
89
Air Cleaners, Humidifiers, Dehumidifiers, Air Filters Pipe Thread Sealers, Lubricants, Hand Cleaners, Cleaners & Degreasers, Fuel Oil & Boiler Chemicals, Fuel Oil Chemicals Wires, Fuses, Wire Nuts, Fittings, Boxes, Plates, Devices, Breakers, Testers, Light Bulbs, Staples Filter Grills, Sidewall Grills, Sidewall Registers and Diffusers, Floor Registers & Returns, Floor Diffusers, Multi-Pattern Ceiling Diffusers, Ceiling Diffusers, Baseboard Diffusers, Baseboard Grilles, Diffuser Boot & Damper, Forced Air Zone Controls, Static Pressure Control, Universal Zone Control Systems Primary Controls, Aquastats, Combination Controls, Pressuretrols, Fan & Limits, Switching Relays, Fan Controls, Fan Centers & Contractors, Low Voltage Transformers, Heat Manager, Boiler Reset Expansion Tanks & Accessories, Backflow Preventers, Air Vents, Gauge Glass, Relief Valves, Pressure Reducing Valves, Low Water Cut-Offs & Feeders, Flow Switches, Circulators & Accessories, Valves, Zone Valves, Flow Control Valves, Manifolds & Heaters, Tankless Coils, Radiants Burner & Blower Motors, Circulator Motors & Accessories, Blower Parts, V-Belts Gas Burner, Ignition Modules, Gas Valves, Thermocouples & Thermopile Generators, Pilot Burners & Orifices, Hot Surface Ignitors, Regulators, Track Pipe, Yellow Gas Pipe Fittings & Accessories, Gas Pipe, Tubing & Fittings, Shut Offs
continued4
TblContent.indd 1
3/24/08 12:34:10 PM
F.W. Webb Company
TECHNICIAN’S HEATING CATALOG Table of Contents Section 9 10
11 12 13 14 15
16
TblContent.indd 2
Page Nozzles
126
Oil Heating
131
Pipe & Fittings
153
Testing Equipment
161
Thermostats
171
Tools
188
Venting
208
Technical Information
228
Hago Oil Burner Nozzles, Delavan, Nozzle Adapters, Nozzle Changers, Telescoping Mirrors, Nozzle Boxes Oil Burners, Replacement Parts & Accessories, Electrodes, Tune Up Kits, Transformers, Terminal Kits, Ignition Cable, Buss Bars, Fuel Oil Filters, Spin-On Filters, Filter Refill Cartridge, Filter Draining System, Replacement Cartridges, Oil De-Aerator, Oil Lines, Handpump, CO2 Blowout Gun, Magnetic Valves, Pumps, Oil Burner Coupling & Accessories, Burner Blower Wheels Flare Fittings, Brass Flare Fittings, Black Malleable Fittings, Fittings & Nipples, Tank Bushings, Nipple Box, Schedules 40 & 80 Black Pipe Electrical Meters, Combustion Testing Accessories, Oil Burner Testing Low Voltage Thermostats, Line Voltage Thermostats, Digital Thermostats, Programmable Thermostats, Subbases, Thermostat Guards Soldering Kits, Solder & Paste, Brushes, Vacuum Cleaners, Safety Tools, Flashlights & Batteries, Hand Tools, Power Tools, Screws & Drill Bits Power Venters & Draft, Combustion Air, Power Venters & Draft Regulators, Power Venter Parts & Controls, Power Venters, Power Venter Parts, Z-Flex, Chimney Troubleshooting, Helpful Hints, Cross Reference
Index
i–x
3/24/08 12:34:12 PM
SECTION
1
Air Cleaners LIFEBREATH® Heat Recovery Ventilators (HRVs)
1
Model No. 155MAX 200MAX Airflow wg (Pa) CFM(L/S) CFM(L/S) .1 (25 Pa) 150 (71) 207 (97) .2 (50 Pa) 146 (69) 200 (94) .3 (75 Pa) 134 (63) 184 (87) .4 (100 Pa) 121 (57) 171 (70) .5 (125 Pa) 106 (50) 152 (71) Defrost Type Recirculate Recirculate Dimensions H X W X D (in.) 19 X 33.62 X 14.75 19 X 33.62 X 14.75
19 X 49 X 14.75
mfr# 155MAX 200MAX 195DCS
webb# 164614 164615 164617
description Heat Recovery Ventilator Heat Recovery Ventilator Heat Recovery Ventilator
AIR QUALITY
Our compact, electronically-powered HRV moves stale, contaminated, warm air from inside the house to the outdoors. At the same time it draws fresh, oxygen-laden air from outside and distributes it throughout the house. Stale, polluted air is constantly being replaced by an equal quantity of fresh, clean air. • The perfect balance of clean, fresh air. • Installation flexibility. • Most efficient HRV available. • Automatic defrost. • Easy clean filters. • Built-in dehumidistat. • Aluminum heat exchange core. • Premium ball bearing motor. 195DCS CFM(L/S) 203 (96) 191 (90) 182 (86) 167 (79) 155 (73) Damper
HEPA Filtration GSHH3K — Fresh Air & Heat Recovery • In addition to the benefits of the HEPA Filtration Fresh Air Ventilation System, this model as a heat recovery system that preheats air from outside before circulation it throughout the home, resulting in increased comfort. • Recirculation mode available. • Offers 70-105 CFM of fresh air. • Provides a total of 270 CFM of fresh/filtered air. • Installation kit included.
Standard • True HEPA filter included with each unit. • Whole-house HEPA air purification. • Easy installation. mfr# description GSHH3K HEPA Filtration/Fresh Air/Heat Recovery
• Up to 2,500 sq. ft. capacity. • Two pre-filters included. • 2-year warranty. webb# 250097
GuardianPlus™ Air Systems are the only whole-house filtration devices on the market to feature an electronic, low voltage wall mounted control switch for convenient operating flexibility. • Remote control of the systems operating modes. • All electric, low voltage device. • LED indicates systems’ operation mode and signals filter maintenance.
The F.W. Webb Heating Catalog
1_Air Quality_p9.indd 1
F.W. Webb Company
1 3/23/08 7:45:12 PM
Media Whole House Air Cleaners
SECTION
SECTION
1
1
AIR BEAR® Right Angle
RATED MEDIA SIZE MFR# AIR FLOW inches (mm) 447380-002 2000 cfm (3398m 3/hr) 5 D X 20 H X 241/2 W
UNIVERSAL APPLICATION WEBB# Right/Left Hand Installation 202347
MEDIA SIZE MFR# DESCRIPTION inches (mm) WEBB# 255649-102 Air Bear Replacement Media 20 H X 25 W X 5 D 184307 255649-105 Air Bear Replacement Media 16 H X 25 W X 5 D 283321 255649-101 Air Bear Replacement Media 16 H X 25 W X 3 D 202348 255649-103 Air Bear Replacement Media 20 H X 20 W X 5 D 283320
AIR BEAR® Supreme • Air Bear filters capture and hold pollutants inside the filter, allowing air to flow freely through the system. • Highly-efficient, 100% electrostatically-charged synthetic material. Features extended surface pleats that have a higher dirt-holding capacity than competitive filters. • Mounts directly to heating and cooling systems. MFR# DESCRIPTION RATED AIR FLOW MEDIA SIZE inches WEBB# 455602-019 AIR BEAR® Supreme 2000 2000 cfm (3398m 3/hr) 20 H X 241/4 W X 5 D 202345 ® 455602-119 AIR BEAR Supreme 1400 1400 cfm (2379m 3/hr) 20 H X 241/4 W X 5 D 202346
F200E Media Air Cleaner
1
The F200E Media Air Cleaner captures a significant amount of the airborne particles from the air circulated through the unit. Recommended high efficiency media air quality product. • W8600B RF AIRWATCH filter change indicator included. • Integral pressure sensors signal when filter change is required based on increased pressure drop threshold at filter. • Filter change status is transmitted to wall-mounted RF AIRWATCH Indicator. • High efficiency charged-media filter captures particles as small as 0.3 microns. • Rugged zinc-coated, roll-formed cabinet resists corrosion and can support weight of residential furnace and evaporator coil. • Mounts in any position.
AIR QUALITY
• Air Bear filters capture and hold pollutants inside the filter, allowing air to flow freely through the system. • Highly-efficient, 100% electrostatically-charged synthetic material. Features extended surface pleats that have a higher dirt-holding capacity than competitive filters. • Built-in ductwork for installations that require a 90° duct adapter. • Mounts directly to heating and cooling systems.
Media Whole House Air Cleaners
AIRFLOW Additional REPLACEMENT mfr# dIMENSIONS CAPACITY FEATURES FILTERS webb# F200E1003 16” X 20” 1200 cfm Includes FC200E FC100A1003, 370495 high efficiency filter, FC200E1003 pressure sensor and RF AIRWATCH indicator. F200E1011 20” X 20” 1400 cfm Includes FC200E FC100A1011, 370496 high efficiency filter, FC200E1011 pressure sensor and RF AIRWATCH indicator. F200E1029 16” X 25” 1400 cfm Includes FC200E FC100A1029, 370497 high efficiency filter, FC200E1029, pressure sensor and FC100C1009 RF AIRWATCH indicator. F200E1037 20” X 25” 2000 cfm Includes FC200E FC100A1037, 370498 high efficiency filter, FC200E1037, pressure sensor and FC100C1017 RF AIRWATCH indicator.
F100F Media Air Cleaner The F100F Media Air Cleaner captures a significant amount of the airborne particles from the air circulated through the unit. • High efficiency media filter captures particles as small as 0.3 microns. • Mounts in the return air duct. • Rugged zinc-coated, roll-formed cabinet resists corrosion and can support weight of residential furnace and evaporator coil. • Mounts in any position.
F.W. WEBB CARRIES THE COMPLETE LINE OF 90% AFUE FURNACES.
2 1_Air Quality_p9.indd 2-3
F.W. Webb Company
www.fwwebb.com
AIRFLOW MAX. Additional REPLACEMENT mfr# dIMENSIONS CAPACITY FEATURES FILTERS webb# F100F2002 16” X 25” 1400 cfm Includes FC100A filter. No FC100A1029, 370491 AIRWATCH indicator. Dealer FC200E1029, private labeling available. FC100C1009 F100F2010 20” X 25” 2000 cfm Includes FC100A filter. No FC100A1037, 370492 AIRWATCH indicator. Dealer FC200E1037, private labeling available. FC100C1017 F100F2028 16” X 20” 1200 cfm Includes FC100A filter. No FC100A1003, 370493 AIRWATCH indicator. Dealer FC200E1003 private labeling available. F100F2036 20” X 20” 1400 cfm Includes FC100A filter. No FC100A1011, 370494 AIRWATCH indicator. Dealer FC200E1011 private labeling available.
The F.W. Webb Heating Catalog
F.W. Webb Company
3 3/23/08 7:45:28 PM
SECTION
SECTION
1
1
Indoor Air Quality Field Controls
Humidifiers & Accessories
Field Controls
HE120 Whole-House Drum Humidifier
Field Controls offers a complete line of UV-Aire products for any home or business. There are duct-mounted UV-Aire models designed for forced-air heating and cooling systems. These models continuously attack airborne mold, bacteria and viruses as they circulate through the ductwork.
HE265 Bypass Flow-through Humidifier
HE120
Standard Models: UV-12, UV-18 • Hinged cover for easy accessibility. • Includes patent pending angle bracket and duct board mounting kit. • Installs easily and plugs into a standard 120V outlet.
• Humidifier pad is coated with Aglon antimicrobial agent. • Capable of humidifying the largest area, up to 4,200 sq. ft. (386 sq. M) of any Honeywell flow-through humidifier.
• Purifies air in areas up to 500 square feet. • Plugs into any standard 120V outlet. • Attractive, compact design (15”H X 12”W X 12”D).
HE265
Portable Model: UV-1500C • Purifies air in areas up to 1500 square feet. • Plugs into any standard 120V outlet. • Sits on the floor, hangs on the wall, or installs in drop ceiling (24”H X 18”W X 6”D). • Replacement Kit: 1 carbon filter, 4 high-efficiency carbon filters, 1 UV Lamp.
UV-1500C
HE225
24 hours a day / 7 days a week!
1_Air Quality_p9.indd 4-5
F.W. Webb Company
HE365
HM509DG115 TrueSTEAM 9-Gallon Humidifier with TrueIAQ digital IAQ control • Provides humidity independent of equipment operation, allowing homeowners to reach their desired humidity setpoints regardless of air temperature. • Uses up to 70 percent less water to produce even more moisture than traditional whole-house humidifiers. • LED lights indicate when system is running or needs service. Lights also provide feedback to the installer during installation.
webb# 216010 216011 216012 216013 303117 303118 303115 303116
F.W. Webb with WebbConnect™ allows you to: . figure jobs ® WebbConnect . get pricing . order material
4
HE225 Bypass Flow-through Humidifier with H8908B Humidistat • Humidifier pad is coated with Aglon antimicrobial agent. • Small footprint, light weight and reversible components allow for easy mounting on either warm air supply or cold air return of any forced air furnace. • Includes: summer shut-off damper humidifier pad, mounting template, self-piercing saddle valve, 24 Vac transformer and wire, standard Humidistat.
• Replacement Kit: 4 high-efficiency carbon filters, 1 UV Lamp.
mfr# DESCRIPTION UV-12 12” Duct Mounted Unit UV-18 18” Duct Mounted Unit UV-12BULB Replacement Lamp 12” UV12 UV-18BULB Replacement Lamp 18” UV-C UV-500C 500 sq. ft. Portable Air Purifier UV-500RK Kit Replacement 500C UV-1500C 1500 sq. ft. Portable Air Purifier UV-1500RK Kit Replacement 1500C
• Bypass Flow-through Humidifier with H8908B Humidistat. • Humidifier pad is coated with Aglon antimicrobial agent. • Small footprint, light weight and reversible components allow for easy mounting on either warm air supply or cold air return of any forced air furnace. • Includes: mounting template, humidfier pad, self-piercing saddle valve, standard Humidistat.
HE365 Powered Flow-through Humidifier with H8908B Humidistat
Portable Model: UV-500C
UV-500C
AIR QUALITY
For homes and businesses without a forced-air system, Field Controls has developed two new portable UV-Aire models. The portable models combine the purifying power of UV with high efficiency and carbon filtration to reduce dust, pollen, odors and VOC’s.
1
• Bypass Drum Humidifier with standard humidistat. • Includes: mounting template/hardware, saddle valve, 24 Vac transformer and wire, bypass tubing, summer shut-off damper, convertible humidistat control.
www.fwwebb.com
mfr# TYPE HE120A1002 Bypass Reservoir HE225A1006 Bypass Flow-through HE265A1007 Bypass Flow-through HE365A1006 Powered Flow-through HM509DG115 Steam Reservoir
CAPACITY (GAL. PER DAY) MOUNTING 17 GAL Duct Mount 12 GAL Duct Mount 17 GAL Duct Mount 18 GAL Duct Mount 9 GAL Duct or Remote Mount
webb# 370514 372375 370515 370516 370519
Models S2000 & S2020 Steam Humidifiers • Computer watchdog circuit. • Automatic drain/flush system. • Automatic maintenance mode. • Interlocking wiring for Fan Control. • Humidifies without a call for heat. CAPACITY mfr# DESCRIPTION (GAL. PER DAY) S2000 Humidifier Steam 2800 sq. ft. 15GP 16 GAL S2020 Humidifier Steam 3500 sq. ft. 20GP 22 GAL
The F.W. Webb Heating Catalog
VOLTAGE 120 Vac 220 Vac
F.W. Webb Company
webb# 252475 252476
5 3/23/08 7:46:30 PM
SECTION
SECTION
1
1
Humidifiers & Accessories
Humidifiers & Accessories Skuttle Humidifiers
Bypass Humidifier Models S1-HU12MB, S1-HU17MB • Manual humidistat. • B ypass humidifier mounts easily on the warm or return plenum and delivers 12 to 17 gallons per day (depending on the model).
Models 45 & 90
Power Humidifier Model S1-HU18MP • Manual humidistat. • Fan-powered unit mounts easily on the warm air plenum and delivers 18 gallons per day.
Steam Humidifier Models S1-HU12DS, S1-HU12RS • • • • • • • •
Multiple installation options: duct mount, room mount or remote mount. 1 20V and 230V options. Self-contained immersed electrode design. Disposable steam-generating cylinder. High water level and foam detection monitoring. Capacities 12 lbs./hr. Pure, sterile steam delivering premium indoor air quality. Digital automatic humidistat.
mfr# S1-HU12MB S1-HU17MB S1-HU18MP S1-HU12DS S1-HU12RS
45SH
Model HE360 Powered Flow-through Humidifier Powered Flow-through Humidifiers use the warm air furnace blower to provide whole house humidification. • Capable of humidifying the largest area, up to 4,200 sq. ft. (386 sq. M) of any Honeywell flow-through humidifier. • Interior components designed for quick maintenance and service. • Includes easy-to-use humidistat which mounts on the wall or duct for more installation flexibility. • Perfect Climate comfort Center™ control can be installed instead of the humidistat for improved aesthetics and convenience. • Standard testing per ARI Standard 610.
webb# 21872 21873
• Designed to fit today’s narrower plenums — as narrow as 14”. • Reversible side panels with unique snap-lock fittings permit easy-change left-side or right-side by-pass installation. • New, improved wicking and water distribution system allows for non-level plenums. • Durable thermoplastic cabinet resists rust, corrosion and warpage. • Low profile makes unit ideal where space is limited.
2002
Bypass Flow-through Humidifiers use the warm air furnace blower to provide whole house humidification. • Preassembled for quicker installation. • Small footprint, light weight and reversible components allow for easy mounting on either warm air supply or cold air return of any forced air furnace. • Interior components designed for quick maintenance and service. • Includes easy-to-use humidistat which mounts on the wall or duct for more installation flexibility. • Perfect Climate comfort Center™ control can be installed to replace both the thermostat and humidistat for improved aesthetics and convenience. • Standard testing per ARI Standard 610. • Includes: Bypass Flow-through Humidifier, humidifier pad, mounting template, self-piercing saddle valve 24 Vac transformer and wire, humidistat.
description By-Pass Humidifier — 10 Gals./Day By-Pass Humidifier — 17 Gals./Day
Models 2000, 2001 & 2002
description webb# 12 GPD By-Pass Humidifier 24V with Manual Humidistat 101987 17 GPD By-Pass Humidifier 24V with Manual Humidistat 101766 18 GPD Power Humidifier 120V with Manual Humidistat 96789 12 lbs./hr. Duct Steam Humidifier 240V 360354 12 lbs./hr. Room Steam Humidifier 240V 360351
Model HE260 Bypass Flow-through Humidifier
mfr# 45SHI 90SHI
1 AIR QUALITY
Models 45 & 90 Drumatic By-Pass Type Furnace Humidifiers are designed to deliver high humidity output when used on warm-air heating systems. Fresh water flows into the distribution pan where the drum rotates and absorbs moisture over the surface of the evaporator pad. The unit features rugged construction with stainless steel cabinet for many years of service. When used in conjunction with the Skuttle® Flushing Timer, service can be drastically reduced to once a year in most cases. The unit allows for flexibility in installation, and can be mounted on either the return air or warm air plenum. ®
mfr# 2000 2001 2002
description Hi Capacity By Pass Flow Thru Humidifier Flow Thru Humidifier — 18 Gals./Day Fan Powered Humidifier — 19 Gals./Day
webb# 166955 151604 151605
Model 190 • Unique snap-lock fittings and reversible components allow quick installation and maintenance. • Uses minimal water and electricity. • Durable thermoplastic cabinet resists rust, corrosion and warpage. • Interior components designed for easy cleaning or replacement. 190
mfr# 190SHI
description webb# By-Pass Humidifier — 17 Gals./Day — Plastic Drum 67466
Replacement Parts mfr# A04-1725-034 A04-1725-033 A05-1721-042 B48-0000-000 A01-1722-018 A01-1722-020
description webb# mfr# description webb# Pad For 90SH 34403 000-0208-000 Humidifier Tablet 80023 Pad For 45SH 34537 SK0-0055-001 Humidistat 80024 24V Motor 56947 A00-1309-005 Float Only For Valve 80039 Float Valve f/45-90 79698 A04-1725-052 Evaporator Pad f/2000 193289 Drum Assembly f/45 79699 A04-1725-051 Evaporator Pad f/2000/2002 201822 Drum Assembly f/90 79700
Self Piercing Needle Valve mfr# Description Webb# 2162 3/8” to 1” 85170
CAPACITY PLENUM OPENING ELECTRICAL mfr# (PER DAY) HEIGHT WIDTH DIMENSIONS RATINGS WEBB# S1-HE260A1044 17 GAL 125/8” 93/4” 155/16”H X 12”W X 91/4”D 24 Vac 341760 S1-HE360A1050 18 GAL 141/16” 131/2” 151/4”H X 14”W X 101/4”D 24 Vac 341761
6 1_Air Quality_p9.indd 6-7
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
7 3/23/08 7:46:52 PM
SECTION
SECTION
1
1
Humidifiers/Dehumidifiers & Accessories
Standard Air Filters
Pleated Air Filters
H46
Physical Data Frame: One-piece moisture-resistant chipboard. Media: Fiberglass or Synthetic. Support Grille: Perforated corrosion resistant steel or expanded wire on both sides of the filter. Sealant: Hot-melt resin. Important Features • One-piece moisture resistant chipboard frame prevents broken corners. • Support grilles on both sides for exceptional strength. • Media and grilled continuously glued to the inside perimeter of the frame for rigidity. • Filters are UL 900 Class 2 listed.
Physical Data Media: High loft, non woven cotton/synthetic blend. Media Support: Diamond shaped expanded metal. Pleat Design: V-Pleat. Frame: Moisture resistant carrier board. Important Features • Media maximizing V-Pleat design. • Expanded metal grid prevents media flutter while in operation. • Diagonal and horizontal support members provide frame strength. • Filters Media pack is sealed to eliminate air bypass. • Average ASHRAE efficiency is 25 – 30%. • Average arrestance is 90% – 92%.
HUMIDITY RATINGS, mfr# APPLICATION COLOR VOLTAGE Operating H46C1000 Dehumidification Beige 24 Vac, 120 Vac, 240 Vac 20% - 80% RH H46D1032 Humidification Beige 120 Vac, 240 Vac 10% - 60% RH
webb# 99184 100813
H69 Mount in return air duct of a forced air heating system to control a central humidifier or dehumidifier. • External knob on front of case provides control point adjustment. • Humidity sensing element is moisture-resistant nylon ribbon wound around three bobbins. H69
Humidity Ratings, mfr# Application Operating H69A1014 Humidificaton Or Dehumidification 35% - 65% RH
webb# 107381
H600 Operates humidification equipment on RH fall or dehumidification equipment on FH rise. • Sensing element of thin, moisture sensitive nylon ribbon provides reliable operation even when ambient temperature conditions change. • Fully enclosed, dust free, SPDT, snap-acting switch. • Removable setting knob prevents tampering. • Mount vertically on 2” X 4” junction box (not to be duct mounted). • Includes alternate scale and faceplate for horizontal mounting. H600
mfr# H600A1014
description Dehumidifier/Humidifier
webb# 106671
Sail Switch S688 Used in forced air systems to activate electronic air cleaners, humidifiers, or other auxiliary equipment in response to airflow from system fan. • Used in electric air systems to prove minimum airflow. • Allows auxiliary equipment, such as humidifiers, duct heaters, or damper motors to be wired independently of blower motor. • Senses vertical or horizontal airflow with appropriate selection of bias spring. • Consists of polyester film sail mounted on an SPDT, Micro Switch snap-acting switch. S688
mfr# S688A1007
description Air Flow Switch
1” Mfr# & size 10X10X1 10X20X1 10X25X1 12X12X1 12X24X1 14X20X1 14X22X1 14X25X1 15X20X1 15X25X1 16X20X1 16X25X1 20X20X1 20X25X1 25X25X1
1_Air Quality_p9.indd 8-9
F.W. Webb Company
webb# 9781 9780 153476 194765 56657 111266 166946 79886 9789 80190 7570 7569 7568 7567 30780
Mfr# & size 10X20X2 12X24X2 14X20X2 14X25X2 15X20X2 15X25X2 16X20X2 16X25X2 20X20X2 20X25X2 25X25X2
Other sizes available.
• Constructed of space-age, non-corrosive materials. • Patented 4-stage loading design/peak & valley webbing • Contains No Foam to clog or deteriorate. • Cleans easily and effectively — No oil sprays or expensive cleaners required! Mfr# 16X20X1A2000 16X25X1A2000 20X20X1A2000 20X25X1A2000
webb# 79629 79631 79635 79637
Cut to Size Washable Air Filter
webb# 55516
www.fwwebb.com
webb# 112256 80191 151312 151313 9786 80192 9785 9792 9791 9790 56659
Electrostatic Air Filters
Mfr# SM100
8
2”
webb# 109647
The F.W. Webb Heating Catalog
1 AIR QUALITY
Humidity Controller Provide automatic control of a humidifier or dehumidifier for dehumidification and mildew control in air conditioning systems. • Positive ON-OFF settings permit manual operation of controlled equipment. • Impact-resistant, molded plastic cover mounts on wall. • Fully enclosed, dust free, SPST, snap-acting switch. • Sensing element of thin, moisture sensitive nylon ribbon provides reliable operation even when ambient temperature conditions change. H46
Air Filters
2”
1” Mfr# & size 10X10X1P 10X20X1P 12X24X1P 14X20X1P 14X25X1P 15X20X1P 16X20X1P 16X25X1P 20X20X1P 20X25X1P 25X25X1P
webb# 165504 165486 151311 112360 112358 112359 76474 76475 76477 112357 112356
Mfr# & size 12X24X2P 14X20X2P 14X25X2P 15X20X2P 16X20X2P 16X25X2P 20X20X2P 20X25X2P 25X25X2P
webb# 112366 112365 112361 112364 76479 76480 76481 76482 165508
Other sizes available.
PopUP™ Media Replacement Filter • No Assembly Required—No combs, pleat spacers or end caps. Filters literally pop-up ready to use, saving you time on the job. • Application Flexibility—Available in six universal sizes that fit Honeywell models and other brands. • Homeowner Friendly—Self-assembly feature helps generate easy replacement sales. • Extra Filtration—Unique design offers an additional 1” of filtration depth compared to standard cartridge replacement filters. • Meets American Lung Association® Health House® guidelines. Mfr# Sizes webb# • Collapsible Design— POPUP1620 16 X 20 322036 Less chance of damage POPUP1625 16 X 25 322035 to filter. POPUP2020 20 X 20 POPUP2025 20 X 25 Mfr# Sizes POPUP2200 Replaces Space-Gard®/ Aprilaire® 2200 POPUP2400 Replaces Space-Gard®/ Aprilaire® 2400
F.W. Webb Company
322034 322033 webb# 322037 322038
9 3/23/08 7:47:02 PM
Pipe Thread Sealers
SECTION
SECTION
2
2
Lubricants
Thread Sealants RectorSeal® No. 5® pipe thread sealant is a
soft-set, slow drying compound which seals, lubricates, and protects threaded pipe and fittings. It can be pressurized immediately for piping up through 2” and 100 psi. for use on threaded galvanized steel, iron, brass, copper, aluminum, stainless steel, polyethylene, fiberglass reinforced, PVC & CPVC pipe. description webb# 110947 1/2 Pint 16882 1 Pint 16883 1 Quart 16884 1/4 Pint
RectorSeal® T Plus 2® pipe thread sealant
is a non-setting, multi-purpose compound which contains Teflon plus synthetic fibers to create a stronger seal. For use on threaded galvanized steel, iron, brass, copper, aluminum, stainless steel, polyethylene, fiberglass reinforced, PVC, CPVC & ABS pipe. mfr# description webb# 23431 1 Pint 150352
RectorSeal® Tru-Blu™ pipe thread sealant with Teflon is a fast-dry, flexible set thread sealant designed for high vibration environments such as refrigeration and industrial applications. For use on threaded galvanized steel, iron, brass, copper, aluminum, stainless steel, polyethylene, fiberglass reinforced, PVC, & CPVC pipe. mfr# description webb# 31431 1 Pint With Teflon 68533
Pipe Thread Grease Y70 pipe thread grease is sold in 21/2 oz. net weight single tubes. Y70 grease is especially compounded to provide excellent lubrication at temperatures ranging from 32 to 175°F. It will not run at high temperature and remains plastic at low temperature. mfr# description webb# Y70AA-1 21/2 oz. Tube 188175
10 2_Chemicals_p15.indd 10-11
F.W. Webb Company
mfr# description ProDope® 15-420 1/2 Pint 15-427 1 Pint Grrip™ 15-510 1/4 Pint Joint Sealant 15-515 1/2 Pint Joint Sealant Real-Tuff™ 15-615 1/4 Pint Joint Sealant 15-620 1/2 Pint Joint Sealant 15-625 1 Pint Joint Sealant 15-630 1 Quart Joint Sealant MegaLoc™ 15-806 1/2 Pint Joint Sealant 15-625 1 Pint Joint Sealant BluBloc™ 15-707 1/2 Pint Joint Sealant with Brush 15-711 1 Pint Joint Sealant
webb#
Chemicals mfr# description Lube Oil 40-404 With Extenda Spout Thread Cutting Oil 40-115 1 Quart Clear 40-120 1 Gallon Clear 40-215 1 Quart Dark 40-220 1 Gallon Dark 40-225 5 Gallon Dark 40-240 55 Gallon Dark
11236 11237 11238 11239 11241 11242 11243 55504
PERMATEX INDUSTRIAL
190100 68694 68693 152701
PERMATEX Thread Sealants INDUSTRIAL & Gasket Silicone mfr# description webb# High Performance Thread Sealant 56521 50 ml. Tube 44407 Thread Sealant with Teflon 80632 4 oz. Can 44387 80633 16 oz. Can 44388 Black Silicone Adhesive Sealant 81173 3 oz. Tube, Carded 44395 81158 11 oz. Cartridge 44394 Sensor-Safe Blue RTV Thread Sealant 80022 3 oz. Tube, Carded 44329 80023 12 oz. Tube, Boxed 44325 Ultra Blue® RTV Silicone Gasket Maker 81724 3.35 oz. Tube, Carded 44381 High-Temp Red RTV Silicone Gasket 81160 3 oz. Tube, Carded 44358 85915 7.25 oz. Automatic Tube 44372 81409 11 oz. Cartridge 44368 Aviation Form-A-Gasket® No. 2 80009 1.5 oz. Tube, Boxed 44315 80016 3 oz. Tube, Boxed 44316 80011 11 oz. Tube, Boxed 44317 Pipe Joint Compound 80045 16 oz. Bottle 44393 Rubber Adhesive/Sealant 80855 11 oz. 44395
Thread Cutting Oils
webb# 11292 15255 15257 15254 15256 15258 15260
Lubricants
mfr# description webb# Ultra Slick™ Synthetic Lubricant With PTFE 81943 12 oz. Aerosol Can 72961 Fast Break® Super Penetrant 80052 16 oz. Aerosol Can 44396 Silicone Spray Lubricant 80070 16 oz. Aerosol Can 44332 Anti-Sieze Lubricant 80078 8 oz. Brush Top 44337 80208 16 oz. Brush Top 44340
• Cools threads and pipe during operation. • Speeds metal removal. Ridgid thread cutting oils are free of chlorine and other halogens, PCBs and heavy metals. Complete material safety data sheet available. Dark Oil – Traditional mineral oil with low odor and antimist formulation. Nu-Clear Oil – Clear mineral oil with low odor and antimist formulation. Special low temperature properties maintain workable viscosity to -20F. Stainless Steel Oil – High performance mineral oil formulated to produce superior quality threads on stainless steel and black pipe. Water Washable – Synthetic thread cutting fluid cleans easily off concrete, clothing, and piping with water. Biodegradable.
2 CHEMICALS
mfr# 25631 25551 25431 25300
Thread Sealants
mfr# Description Webb# 70835 1 gal. Nu-Clear 178052 41575 5 gal. Nu-Clear 17035 70830 1 gal. Dark 199558 74007 1 qt. Stainless Steel 214680 74017 1 qt. Water Washable 214682 74022 1 gal. Water Washable 223739
Spray Lubricant mfr# description L3-12 11 oz. Spray WD-40 WD40 11 oz. Spray
webb# 52684 200106
Hand Cleaners PERMATEX INDUSTRIAL mfr# description webb# 12756W Wipes/Tub 94920 Waterless Soft Gel Hand Cleaner Heavy Duty 51-224 16 oz. Citrus 262024
Leak Lock mfr# description webb# 93807 1.3 oz. 222295 93804 4 oz. 222296
www.fwwebb.com
The F.W. Webb Heating Catalog
mfr# description Trounce® 03-013 14 oz. Tub, Cream Fast Orange® 25-108 7.5 oz. Bottle 25-116 15 oz. Bottle 25-218 1 gal. Bottle w/Pump Blue Label™ 01-013 14 oz. Tub, Cream
webb# 57963 57965 57966 68447 249527
F.W. Webb Company
11 3/23/08 7:53:57 PM
SECTION
SECTION
2
2
Cleaners & Degreasers Degreasers Super Degreaser Heavy Duty Mechanical Degreaser
MFR# DESCRIPTION WEBB# 57-121 16 oz. 111159
Super Foam Cleaner No Rinse Degreaser Super Foam Cleaner is non-corrosive and 100% biodegradable. Its fast-acting foam will clean away all grease, grime, dirt, oxidation, and oil without the need to rinse with water. Use to deodorize and eliminate the source of unwanted odors while it cleans. Good for cooling coils, boiler jackets, garage floor, engines, motors, white walls, printing presses. • Self-rinsing, fast breaking foam. • CFC free, low V.O.C. • Will not contaminate oil. MFR# DESCRIPTION WEBB# 56-099 16 oz. 111160
Mfr# Description Webb# WNDGAL 1 Gallon 72320
Soot Remover Stick
Zipp™
Destroys soot quickly by catalytic low temperature ignition. Fits through combustion chamber openings. Non-corrosive, non-explosive.
Is a quick drying degreaser for cleaning electrical equipment and small mechanical parts. Removes oil and grease in hard-toreach places.
Mfr# Description Webb# 35-515 Soot Remover Stick 58554
Speedy Dry Absorbant Mfr# Description Webb# 50 50 lb. Bag 67396
mfr# description Cold Galvanizing Compound 82039 16 oz. Aerosol Can
Zipp™ II Soot Spray It reaches where vacuum cleaners can’t. Cuts vacuum time by 50-100%.
PERMATEX INDUSTRIAL
Mfr# Description Webb# 35-620 16 oz. Soot Spray 73795
webb# 52914
Colco Cements MFR# DESCRIPTION WEBB# 325 30 lb. Bucket Refractory Cement 209729 HTDCEM6LB 6 lb. Can Hydraulic Cement 202085 MORTAR 25 lb. Bag Mortar Mix 69661 READYMIX 25 lb. Bag Ready Mix Cement 70309 STICON 50 lb. Bag Stic On 69663
2_Chemicals_p15.indd 12-13
F.W. Webb Company
Mfr# Description Webb# 82645 12 oz. Zipp II Spray 193971
Liquid Burnisher
Is a foaming cleaner-degreaser that emulsifies and flows away grime and dirt. Use on heating and air conditioning equipment and all types of machinery that can be rinsed with water or wiped with a rag. Non-flammable.
Is an electrical contact point cleaner. Flushes off metallic oxides caused by moisture, arcing, greasy films or dirt. Mfr# Description Webb# 88412 6 oz. Liquid Burnisher 69642
Mfr# Description Webb# 88436 14 oz. Grime Solv 69640
Acid-Away® Is a unique chemical treatment for use in air conditioning and refrigeration systems that have experienced burnout, or operating systems that are showing a buildup in acid content. Mfr# Description Webb# 45004 4 oz. Acid Away 90566
Did you know? offers a full line of environmentally friendly chemicals
MFR# DESCRIPTION WEBB# 56-130 16 oz. 261713
12
Is an environmentally safer version of Zipp™. This quick drying degreaser removes grease, oil, wax, tar, gum, grime, dirt, carbon and greasy stains from most hard surfaces.
Grime-Solv™
Grease Gone Heavy Duty Degreaser Grease Gone is unmatched in its ability to liquefy and lift greasy grime to allow it to be wiped away easily. It cuts through greasy build-up fast and works well on hundreds of applications where heavy oils, grease and grime removal is required. For use on all industrial and farm mechanical parts, tools, machinery, engines, fuel oil related components, bicycles, refrigeration parts and much more. Safe on all hard surfaces. • Biodegradable, phosphate free. • Liquefies grease, carbon, dirt for easy clean up. • Fast and effective. • Will not give “hot” reading in waste oil.
2
Mfr# Description Webb# 82642 14 oz. Zipp Spray 69641
CHEMICALS
Super Degreaser is the environmental answer to degreasing. It’s biodegradable formula air dries, is non-chlorinated and will not contaminate oil. Super Degreaser removes all oil-based grease (tar, dirt, grime, slime, carbon, engine deposits), leaves no film and is safe on all plastics and metals. No rinsing necessary. • USDA Authorized. • CFC free. • Will not contaminate oil.
Windshield Wash
Cleaners & Degreasers
www.fwwebb.com
F.w. webb is the exclusive distributor of the Energy Star Rated Trio Cast iron boiler. The F.W. Webb Heating Catalog
F.W. Webb Company
13 3/23/08 7:54:12 PM
SECTION
SECTION
2
2
Fuel Oil & Boiler Chemicals Cryo-tek™ — 100 Anti-freeze When used undiluted, gives anti-freeze protection to –100°F (–73°C) for hydronic heating, cooling, potable water and closed loop solar systems. Non-toxic. Contains chemical ingredients to prevent corrosion. For homes, recreational vehicles, mobile homes, trailers, boats and industrial use. Excellent heat transfer agent for solar systems.
mfr# description Boiler System Cleaner 36-135 1 Quart Hydronic System Cleaner 36-335 32 oz. Steam Boiler Cleaner 36-213 8 oz.
Water Management Inc.
RhoGard™ — Aluminum Safe Multi-Metal Anti-freeze • Hydronic system freeze, corrosion and scale protection fluid. • Contains PRO-TEK™ inhibitors. • Burst protection to –100° F. • Environmentally friendly. description 5 Gallon RhoGard
webb# 361918
webb# 277253
Hydro-Solv™ 9100 — Hydronic System Cleaner for New and Used Systems • Specially formulated for Hydronic systems. • Clean, solder-flux, cutting oil, rust and dirt. • Removes scale and corrosion from fouled systems. • Removes bacteria. • Efficiently cleans aluminum, brass, copper, iron and steel. • Environmentally friendly. mfr# RHOMAR9100
14 2_Chemicals_p15.indd 14-15
description 1 Gallon System Cleaner
11268 11270
webb#
webb# 277254
F.W. Webb Company
MFR# DESCRIPTION WEBB# 61-621 8 oz. Cherry 244244 61-630 8 oz. Mint 316296 61-625 8 oz. Orange 316295
11272
Killem is an oil soluble product, EPA approved as a biocide, for the control of bacteria and fungi growth in oils and refined fuels. Killem will control micro-organisms in fuel oil storagetanks, fuel oil and other refined or partially refined oils. Killem will reduce tank corrosion, slime mats, odors, fuel oil filter deposits and plugging, fuel-water separator deposits, excess carbon deposits and smoke.
2
Mfr# Description Treats (gal) Webb# 00119 16 oz. Bottle 1,920 88153
Aquasorb™ Is the most powerful water and sludge dispersant for fuel tanks. Prevents ice blockage, sputtering flame, and sludge. Avoids corrosion-caused leaks. Mfr# Description Webb# 68404 1 Quart Aquasorb 69638
69646
Hot 4 in 1 Heating Oil Treatment Totally disperses water and controls waxing and gelling.
69645
Refractory/Retort Repair Cement
• Approved for major boiler manufacturers. • Protects aluminum, brass, copper, iron and steel. • Prevents scale. • Removes oxgen. • Keeps efficiency high. • Environmentally friendly. • Compatible with Anti-Freeze. description 1 Gallon PRO-TEK
11266
Furnace Cement
PRO-TEK™ 922 — Boiler Treatment for Aluminum and Multi-Metal Systems
mfr# RHOMAR922
Heavy duty, long lasting fuel oil deodorizer. Good for all types of deodorizing problems — just flip up cap or unscrew lid for desired effect. Great for oil spills in enclosed spaces, service trucks, homes, offices, cars, boats, R.V.’s and basements. They will eliminate the foul odor and replace it with a sweet cherry scent. • Pleasant cherry, orange or mint scent. • Long-lasting, self-dissolving gel. • Biodegradable. • Environmentally friendly.
webb#
Boiler System Treatments
Rhomar
mfr# RHOMARAF
mfr# description Boiler Weld Liquid 41-135 1 Quart Hydronic Leak Seal 36-338 16 oz. Sealant Boiler Weld Powder 41-222 1 lb. Powder
Killem
CHEMICALS
MFR# DESCRIPTION WEBB# GAL Gallon 48610 5GAL 5 Gallon 48611 30GAL 30 Gallon 48612 55GAL 55 Gallon 48613 Cryo-Tek™ Anti-Freeze Test Kit 67868 35-271 Cryo-Tek™ Inhibitor 35-275 6 oz. 85027
Heavy Duty Deodorant Gel Cup
Boiler & Heating System Stop Leaks
Anti-Freeze
Fuel Oil Chemicals
• Provides strong bonding for setting firebrick, sealing flue pipes, chimney collars and for sealing around chamber doors and burner cones. • Preferred cement of choice by heating professionals. • Non-asbestos, high temperature 3000°. • Will not sag, crack, crumble, shrink, or pull away. • Non-freezing to -7°F. • Environmentally safe and non-toxic. MFR# DESCRIPTION WEBB# 40-365 1/2 Gallon 243248
Odor Out Spray and Odor Absorbent Powder Fuel Odor Neutralizer/Remover Cherry scented Odor Out comes in spray or powder form. Can be used in air conditioning filters, window units, central units and automobiles for a breath of fresh air. • Stops odor. • Absorbs oil. • Refreshes the air. • Neutralizes fuel odors resulting from spills. • Use in heating and air conditioning ducts. MFR# DESCRIPTION WEBB# 61-520 16 oz. Spray 243249 61-620 1 lb. Powder 243250
Hot 4 in 1 is the best at: • Dispersing water. • Getting rid of sludge. • Improving atomization— reducing soot. • Preventing waxing and gelling. Mfr# Description Treats (gal) Webb# 4-1 16 oz. Bottle 275 70277
Meltdown Meltdown is specifically formulated to dissolve gelled fuel back into solution and return the flow in approximately 20 minutes. It will not harm fuel pumps, nozzles, or any precombustion components. Meltdown is an emergency fuel treatment only: Hot is recommended for preventative maintenance. Mfr# Description Treats (gal) Webb# 00330 1 Gallon Jug 200 91323
SBG SBG means “sludge be gone.” SBG is formulated to eliminate sludge and water. SBG’s specially formulated chemical base dissolves the sludge into a combustible substance in such a way as not to clog nozzles, while assuring clean filters and strainers. Helps to improve atomization and will provide more efficient combustion. Mfr# Description Treats (gal) Webb# SBG 32 oz. Bottle 1,000 179166
www.fwwebb.com
The F.W. Webb Heating Catalog
8-Way™ Is a complete boiler water treatment for both steam and hot water systems. • Removes sludge & rust scale. • Unhibits boiler & steam line corrosion. • Prevents oxygen pitting. • Inhibits lime scale. • Prevents surging and foaming. Mfr# Description Webb# 68712 1 Quart 8-Way 69639
Water Finding Paste Mfr# Description Webb# 61-405 2 oz. 55862
WP-3 Advanced Heating Oil Additive Sludge Buster & De-Icer Concentrate Next generation of fuel oil additive that stabilizes fuel, dissolves sludge, lowers pour point and disperses water. Helps prevent fuel line freeze-ups. • Stabilizes fuel and dissolves sludge. • Inhibits rust and tank corrosion. • Lowers pour point for better cold weather combustion. • Melts ice and helps prevent fuel line freeze-ups. MFR# DESCRIPTION WEBB# C50W 8 oz. Bottle, (treats 275 gal. tank) 253448 C50-1W 1 Gallon “Tip-N-Pour” Bottle 259930
F.W. Webb Company
15 3/23/08 7:55:45 PM
Electrical Wire-THNN-Romex
1/2”
3
3
Wire Nuts
description webb# 18/2 UL, 500’ 18/3 UL, 500’ 18/4 UL, 250’ 18/5 UL, 250’ 18/6 UL, 250’ 18/8 UL, 250’
SECTION
2597 2598 88328 70312 149494 149495 69880
Red, 500’ White, 500’ Black, 500’ Blue, 500’ Green, 500’
69881 69882 69883 69884 71444
14/2, 250’ 12/2, 250’
70047 70048
mfr# Wire Nuts WT1-1 WT2-1 WT3-1 WT4-1 WT6-1 30-092
Boxes
description webb# Gray Blue Orange Yellow Red Green
70049 70037 69898 69899 69900 261630
Fittings mfr# Coupling TC-511
description webb# 1/2” SS
Connector EFC50 1/2” X 3/8” EMT Flex EMT to Box Connector TC-501 1/2” SS Connector AC90
3/8” 90D Flex
69901 69902 69903 70301
BX/Conduit/Fuses mfr# description webb# Wire (BX With Ground, 250’) 122MC BX 12/2 71443 142MC 14-2 Light Aluminum 72551 144 BXL 14-4 BX Wire With Ground 241235 Conduit 12EMT 1/2” EMT Pipe 69885 1/2” EMT Aluminum SS 86982 BLB1 Aluminum Greenfield FLXALM038 3/8”, 100’ 69886 Steel Greenfield FLXSTM038 3/8”, 50’ 72550 Ent Tubing A51AEB1 1/2” Blue Ent Tubing 79302 A51AGA1 3/4” Blue Ent Tubing 148584 Fuses (S Type) GSL15 15A, 125V 69887 GSL20 20A, 125V 69888 GSL30 30A, 125V 69889 Fuses (Edison Type) GTL15 15A 69890 GTL20 20A 69891 GTL30 30A 69892 Cartridge Fuses OT15 15A, 250V 69893 OT20 20A, 250V 69894 OT30 30A, 250V 69895 OT40 40A, 250V 69896
16 3_Electrical_p18.indd 16-17
F.W. Webb Company
One Hole Strap 1901 1902 Connector C500 Duplex Connector DC5500
1/2” 3/4”
Offset Nipple RN50 Corner Pull El’s TL201 Knockout Plugs K050S BL112 EMT Body BLB1 Conduit Body SCV1 Steel Strap M-50 Lock Nut EL100D
69904 136167
3/8” Romex to Box
69906
Duplex 3/8” RX/BX
70298
BX/MC to Box Connector C510 3/8” SS 1/2”
1/2” FEM/FEM
69905 75307 86984
3/4”
86985 86986
1/2 lb., Aluminum/SS
86982
1/2”
1/2 lb., Aluminum
3/8”, 1-Hole Strap 1/2” Zinc
Electrical
86983
148155 84974
www.fwwebb.com
mfr# Square Boxes 521510-1234 52171-1/2-3/4E Handy Box 58361-1/2
Plates description webb# 4” Square, 11/2”D 4” Square, 4”D
69908 75306
21/8W
69909
Octagon Boxes 54151-1/2 4”, 11/2D 54151N 4”, 11/2D With Clamp Square Extension Rings 53151-1/2 Square, 1/2” KO
71439 71440 86976
Switch Box LXWV Plastic Box P118R P122R Ceiling Box
21/2D NMC With BRK
S12ORAC
4” Round
N/O 1G 18CU N/O 22.5 Cube
86978 158692 71441
(cont.)
mfr# Recepticle, 1 Gang SP8W SP8 SP8I Recepticle, 2 Gang
description
webb#
White Brown Ivory
92409 92428 92429
SP82I Switch, 1 Gang
Ivory
92437
SP1 SP1I Switch, 2 Gang
Brown Ivory
92426 92427
SP2I Ivory Porcelain Recepticle
92432
288 Switch Plate
With 1 Plug
86980
TP1W
White
92408
3 electrical
mfr# Thermostat Wire TW18/2-500 TW18/3-500 TW18/4-250 TW18/5-250 TW18/6-250 TW18/8-250 Flexible Tube 12LQ100 THHN 14 Solid Wire THHN14SOLRED500 THHN14SOLWHT500 THHN14SOLBLK500 THHN14SOLBLU500 THHN14SOLGRN500 Romex Wire NMB14/2WG250 NMB12/2WG250
SECTION
158656
Devices
Plates mfr# description Red Oil Burner Switch Covers 41001 Cover Burner Switch 41006 4” Square Single Switch 41009 4” Square Two Switch 41005 1G Handybox Cover 41009 1G Switch Box Cover Plain Switch Covers 11413 4” Square With Switch & Recepticle Cover
webb# 69912 69910 69911 69916 69911 71442
11401
4” Square Single Cover
69912
11410
4 X 4 Two Switch Cover
69913
11402
Duplex Recepticle Cover
69914
52C6
4” Square Blank Cover
69915
54C1
4” Round Blank Cover
76733
10004
Handi Box Switch Cover
69918
10001 Handi Box Blank Cover 10002 Handi Box Duplex Recepticle Cover Red Gas Burner Switch Covers
69919
41025 41026 41024
4” Square Single Switch 4” Square Two Switch Handybox Cover
69924 69925 69926
41020
1G Switch Box Cover
76732
The F.W. Webb Heating Catalog
mfr# Toggle Switch
description webb#
660G
Single Pole, Brown
69921
6601G
Single Pole, Ivory
75310
3232
Brown
69922
32321
Ivory
75311
With Pull Chain
69923
15A, Brown 15A, Ivory 15A, White
92424 92425 92407
Brown Ivory
92420 92421
Duplex Recepticle
Current Tap 1406 GFI Recepticle 1591 15911 591SW 3-Way Switch 663GB 663IG
69920
F.W. Webb Company
17 3/23/08 8:15:30 PM
SECTION
3
Electrical Breakers
Miscellaneous
mfr# description webb# Square D Circuit Breakers Q0120 Single Pole, 20A 76722 Q0220 Two Pole, 20A 76723 ITE Circuit Breakers Q0115 Single Pole, 15A Q120 Single Pole, 20A Q215 Two Pole, 15A Q220 Two Pole, 20A Q230 Two Pole, 30A Homeline Circuit Breakers HOM115 Single Pole, 15A
76724 92497 92447 77329 92449 216375
Testers mfr# Multimeters
description webb#
BPY13 Voltage Detector 1010 Volt Tester 970C E217
Mini Analog
86966
AC Detector
86968
Tester With Probe, 60-500V Low Voltage Tester 5-50V
86969
White Flourescent F40CW/ES F96T12/CW/ES F96T12/CW/HOES
34W Energysaver 60 W Energysaver 95W Energysaver
70206 86981 150624 150625 150627
Staples mfr# Insulated Staples P100-5 SN40-I-100 Staples SN40-100
18 3_Electrical_p18.indd 18
CP58 Ground Rod Clamp
5/8” x 8”
142382
GA203 G5 Duct Seal 31-601
1/2” – 1” 5/8” All Copper
92462 92462
1 lb. Block
70251
BX/MC
75308
8’
53597
Extension Cords EC530825 EC530830 EC530835 EC630830 AD050802
12/3, 25’ 12/3, 50’ 12/3, 100’ 12/3, 50’ 3 Tap 3 Tap Adapter
49103 49104 49105 49107 49112
Test Cord w/Clips 7328
6’
55793
Jumpers Cables IJW18 JW18
18” Insulated 18”
Roto Splitter RS101A Quik-Lok Cord Set 48-76-40081
253289 69734
Firomatic Thermal Switches
description webb# 75W 100W
description webb#
86970
Light Bulbs mfr# Rough Service 75A/RS/IF 100A/RS/IF
mfr# Ground Rod
description webb# Small Insulated #5 1/2 X 1” Romex
69907 86979
1/2 X 1” BX/MC
70299
F.W. Webb Company
mfr# TS150B TS300B HW165
description For Round Junction Box For Square Junction Box Replacement Wheel
webb# 9814 75890 9809
Omco Thermal Cutoffs mfr# description Thermal Cutoffs 95010 165° Round 9600TC 200° Round 95010A 165° Square 9601TC 200° Square Thermal Replacement Fuses 95009A 165° 9509TC 200°
webb# 70269 70270 70271 70272 70273 70274
www.fwwebb.com
3/23/08 8:15:34 PM
SECTION
4
Grills / Registers
Filter Series 19FG
Grills
Series 100M
• 1/2” space fins. • Face fits inside frame. • Removable face. • Positive locking latch (filter not included). mfr# 19FG-12X12W 19FG-20X20W 19FG-24X12W 19FG-24X14W 19FG-24X24W
• Multi-louver damper. • Individually adjusted face bars. • Steel. • White finish.
Outside DIMENSIONS WEBB# 1411/16” X 1411/16” 69109 2211/16” X 2211/16” 55548 2611/16” X 1411/16” 109822 2611/16” X 1611/16” 109761 2611/16” X 2611/16” 69113
Sidewall Grills
Series 19H Horizontal Steel • Grill. • 1/2” curved lanced. • Steel. • White finish. mfr# size WEBB# 19H-8X8W 19H-10X4W 19H-10X6W 19H-10X8W 19H-10X10W 19H-12X10W 19H-12X4W 19H-12X6W 19H-12X8W 19H-12X12W 19H-14X4W 19H-14X6W 19H-14X8W 19H-14X10W 19H-14X12W 19H-14X14W 19H-16X8W 19H-16X12W 19H-16X14W 19H-16X16W 19H-20X12W 19H-24X6W 19H-24X24W
8” X 8” 10” X 4” 10” X 6” 10” X 8” 10” X 10” 12” X 10” 12” X 4” 12” X 6” 12” X 8” 12” X 12” 14” X 4” 14” X 6” 14” X 8” 14” X 10” 14” X 12” 14” X 14” 16” X 8” 16” X 12” 16” X 14” 16” X 16” 20” X 12” 24” X 6” 24” X 24”
75993 69114 54265 69115 69116 69117 54263 54266 54275 54262 109101 54267 69118 69119 54272 54273 54269 83346 83327 58812 54261 54271 55555
The F.W. Webb Heating Catalog
4_Grills_Registers_p24.indd 19
mfr#
Size
100M-8X8W 100M-10X4W 100M-10X6W 100M-12X4W 100M-12X6W 100M-12X8W
8” X 8” 10” X 4” 10” X 6” 12” X 4” 12” X 6” 12” X 8”
webb# 110264 109372 69098 84976 69100 69101
4
Series 10M • Multi-louver. • 1/4” lanced. • Steel. • White finish. • Vertical face deflectors. mfr# 10M-10X6W 10M-12X6W
Outside DIMENSIONS WEBB# 111/2” X 71/2” 12358 131/2” X 71/2” 12359
grills / registers
Sidewall Registers and Diffusers
Series 10V • Multi-louver. • 1/2” lanced. • Steel Series 10V. • White finish. Outside mfr# DIMENSIONS WEBB# 10V-8X8W 10V-10X4W 10V-10X6W 10V-10X8W 10V-12X4W 10V-12X6W 10V-12X8W 10V-14X6W 10V-14X8W
91/2” X 91/2” 111/2” X 51/2” 111/2” X 71/2” 111/2” X 91/2” 131/2” X 51/2” 131/2” X 71/2” 131/2” X 91/2” 151/2” X 71/2” 151/2” X 91/2”
F.W. Webb Company
109590 48781 48782 48783 48784 48785 48786 48787 48788
19 3/23/08 8:20:26 PM
Grills / Registers Floor Registers and Returns
SECTION
SECTION
4
4
Grills / Registers Ceiling Diffusers
Floor Diffusers
Series 20
Series 30
Series 41
Series 60
• Floor register. • O.B. damper. • Steel. • Dura-beige finish.
• Stamped diffuser. • Steel. • White or Dura-beige finish. mfr#
OUTSIDE DIMENSIONS WEBB#
• Steel – White finish. • Accessories. • Series 62 installation frame. • Series 64 Knob Damper.
mfr#
OUTSIDE DIMENSIONS WEBB#
41-2X10
39/16” X 115/16” – Beige
12373
mfr#
OUTSIDE DIMENSIONS WEBB#
30-6X10 30-6X12 30-6X14 30-8X10 30-8X12
77/8” X 117/8” 77/8” X 137/8” 77/8” X 157/8” 97/8” X 117/8” 97/8” X 137/8”
41-2X10W
39/16” X 115/16” – White
80773
1101-8W
131/2” Square
41-2X12
39/16” X 135/16” – Beige
12374
41-2X12W
39/16” X 135/16” – White
179164
41-2X14
39/16” X 155/16” – Beige
12375
41-4X8
55/8” X 95/16” – Beige
41-4X10
55/16” X 115/16” – Beige
12376
41-4X10W
55/16” X 115/16” – White
80776
41-4X12
55/8” X 135/16” – Beige
12377
41-4X14
55/8” X 155/16” – Beige
12378
12385 12386 12387 12388 12389
Series 35
mfr#
OUTSIDE DIMENSIONS WEBB#
35-4X10 35-4X12 35-6X10 35-6X12 35-6X14 35-6X24 35-6X30 35-8X10 35-8X12 35-8X14 35-8X16 35-8X20 35-8X24 35-10X12 35-12X12 35-12X14 35-12X24 35-14X12 35-14X14
57/8” X 137/8” 57/8” X 117/8” 77/8” X 117/8” 77/8” X 137/8” 77/8” X 157/8” 77/8” X 257/8” 77/8” X 317/8” 97/8” X 117/8” 97/8” X 137/8” 97/8” X 157/8” 97/8” X 177/8” 97/8” X 217/8” 97/8” X 257/8” 117/8” X 137/8” 137/8” X 137/8” 137/8” X 157/8” 137/8” X 257/8” 157/8” X 137/8” 157/8” X 157/8”
155275 155276 12394 12395 12396 12397 12398 54278 12399 12400 163692 93611 54279 12402 108612 12403 54277 112194 112195
Floor Diffusers
Series 41F
• BBD grille. • 1/3” lanced. • Steel. • White or Dura-beige finish. 80768
Series 65 • Steel – White finish. • Accessories. • Series 67 thermoplastic installation frame. • Series 68 thermoplastic Knob Damper.
6” Diameter
12369
150-8W
8” Diameter
12370
• Face only. • Steel. • Dura-beige finish.
150-10W
10” Diameter
12371
67P-8XB
8” Round Collar
12362
mfr# 41F-2X10
OUTSIDE DIMENSIONS WEBB# 39/16” X 115/16” 12379
850-4X12
4” X 12” Flr Del
54285
155-6XB
6” Damper Knob
12365
41F-2X12
39/16” X 135/16”
12380
155-8XB
8” Damper Knob
12366
41F-2X14
39/16” X 155/16”
12381
155-10XB
10” Damper Knob
12367
41F-4X10
55/16” X 115/16”
12382
41F-4X12
55/8” X 135/16”
12383
41F-4X14
55/8” X 155/16”
12384
Multi-Pattern Ceiling Diffusers
Series 65
Series 67
Series 68
Baseboard Diffusers Series 71-15
Series 5400 • White. • Aluminum.
mfr#
OUTSIDE DIMENSIONS WEBB#
71-15W 71B-15
15 X 41/2” X 23/4”, White, With Damper 15 x 41/2” X 23/4”, Beige, With Damper
AL173OBD-6
6” X 6”
215459
AL173OBD-8X8
8” X 8”
215460
AL173OBD-10X10 10” X 10”
215461
73647 12404
90790
• Deluxe diffuser. • Steel. • Dura-beige finish.
AL175OBD-6
6” X 6”
90791
AL172OBD-8
8” X 8”
90793
AL174OBD-8X8
8” X 8”
90795
mfr#
AL175OBD-8
8” X 8”
90796
AL175OBD-10
10” X 10”
90801
mfr# 71-18
OUTSIDE DIMENSIONS WEBB# 18 X 5” X 23/4”, Beige, With Damper 12356
AL174OBD-10X10 10” X 10”
90800
71-18W
18 X 5” X 23/4”, White, With Damper
73648
AL163OBD-12
12” X 12”
90804
73-18
18 X 5” X 23/4”, Beige, Less Damper
12357
AL164OBD-12
12” X 12”
90805
73-18W
18 X 5” X 23/4”, White, Less Damper
73649
40-2X12 40-4X10 40-4X12 40-6X12
20 4_Grills_Registers_p24.indd 20-21
39/16” X 135/16” 55/16” X 115/16” 55/8” X 135/16” 77/8” X 155/8”
F.W. Webb Company
54286 54287 54285 54283
webb#
MV2
2 Way Assembly (8X8)
94854
MV3
3 Way Assembly (8X8)
94856
MV4
4 Way Assembly (8X8)
94857
MV360
Diffuser Round With DMP Plastic
243143
Series 71-18
6” X 6”
OUTSIDE DIMENSIONS WEBB#
4
The stepped collar design accommodates 6, 7, 8” or 4, 5, 6” round ducts. Unneeded sections are removed using tearaway bands, no cutting or assembly required. Cut a 9 1/4” diameter hole in the ceiling, attach the Model MV to ductwork and tighten four screws. Mounting clips rotate into position securing the unit in place. • Virtually Airtight Damper—Far superior to any on the market, our patented damper has a rubber gasket for a virtually airtight shut-off. • Damper Handle (Key)—Adjust damper with the screwdriver or included handle (key) which can be removed or left in place. • Mounting Clips—Mounting clips are sized to fit under joists with screws long enough to reach over furring or other obstructions. mfr# Description
AL174OBD-6
Series 40
55542 83035 55543
No Assembly Required
• Series 73 same less damper. • Steel. • Dura-beige or white finish.
mfr# DESCRIPTION WEBB#
OUTSIDE DIMENSIONS WEBB#
20-14X6W 151/4” X 71/4” – White 20-14X8 151/4” X 101/16” – Beige 20-24X6 251/4” X 71/4” – Beige
Diffuser Boot and Damper All In One
Outside mfr# DIMENSIONS WEBB# 150-6W
mfr#
grills / registers
• Floor grille. • Steel. • Dura-beige finish.
111077
Baseboard Grilles
• Series 73 same less damper. • Steel. • Dura-beige or white finish.
www.fwwebb.com
The F.W. Webb Heating Catalog
Did you know that we stock hart & cooley registers/ grills in Many locations? F.W. Webb Company
21 3/23/08 8:20:45 PM
SECTION
SECTION
4
4
Grills / Registers Forced Air Zone Controls Model SMD Side Mount Damper Model SMD is an opposed blade damper. Constructed of clear anodized aluminum with stainless steel direct drive linkage. Model SMD is used in rectangular or square duct. The damper can be oriented in any position although it is typically installed into the side of the duct. Model SMD is available in sizes 6 x 4 thru 30 x 20 in even inch increments. For odd sizes, filler strips can be added. When ordering, specify width by height. Ex. SMD 14 x 8. The actuator will be on the 8” side. mfr# size 8” X 8” 10” X 10” 12” X 8” 12” X 10” 12” X 12” 14” X 8” 14” X 10” 16” X 8” 16” X 10” 18” X 8” 18” X 10” 20” X 8” 20” X 10” 24” X 8” 24” X 10”
105077 107801 102809 107556 107583 105501 107317 108012 107090 97827 106870 106634 100121 105370 106202
Model BMD Bottom Mount Damper Model BMD is an opposed blade damper. Constructed of clear anodized aluminum with a stainless steel direct drive linage. Model BMD is used in rectangular or square ducts. The damper can be oriented in any position although it is typically installed into the top or bottom of the duct. Model BMD is available in sizes 4 x 6 thru 18 x 28 in even inch increments. For odd sizes, filler strips can be added. When ordering, specify height by width. Ex. BMD 8 x 14. The actuator will be on the 14” side. mfr# size 8X10BMND 8X12BMND 8X14BMND 8X16BMND 8X18BMND 8X20BMND 8X24BMND 10X14BMND 10 X16BMND 10X20BMND 10X24BMND
22 4_Grills_Registers_p24.indd 22-23
8” X 10” 8” X 12” 8” X 14” 8” X 16” 8” X 18” 8” X 20” 8” X 24” 10” X 14” 10” X 16” 10” X 20” 10” X 24”
webb# 99943 99966 99979 99999 100019 100035 100063 102999 103022 103062 103098
F.W. Webb Company
Universal Zone Control Systems
Model RD-SR Round Damper – Spring Return Model RD-SR is a round, single blade damper for applications where fast acting, apring open or spring closed actuation is necessary. Model RD-SR can be set to either spring close or spring open by adjusting a set screw. Powers open in 15 seconds and spring closes in 5 seconds or vise versa. Available in sizes 4 thru 14 inches. When ordering, specify round diameter and spring return designation. Ex. RD-SR-8 mfr# size 6URD-ESR 8URD-ESR 10URD-ESR 12URD-ESR
6” Round 8” Round 10” Round 12” Round
Model UZC Revision C
webb# 97668 97692 104546 104572
Static Pressure Control
The Ultra-Zone model UZC is a 3 zone control panel that features auto changeover between the heating and cooling modes. The UZC will accept the first call of heating or cooling and turn the systems on and close the dampers to the zones that are not calling. If another zone calls for the opposite mode, the UZC will hold that call until the first call is satisfied or until a selected time (0 – 60 min.) has passed. Once accomplished, the UZC will go through a time delay to purge the conditioned air out of the system. mfr# Description UZC3
Universal Zone Control System
webb# 190374
Model PRD Model PRD pressure regulating damper is a single blade, steel, barometric damper with a counter balanced weighted arm. The PRD provides an economical solution for bypassing excess air when zone dampers close. Damper adjustment is done by adjusting the supplied weights and by offsetting the arm. SIZES: 12’ x 8”, 12” x 10”, 12” x 12”, 20” x 8”, 20”x 10”, 20” x 12” Other sizes available upon request. mfr# size PRD12X8 PRD220X8
12” X 8” 20” X 8”
webb# 106218 93991
Model PRD-RD Model PRD-RD pressure regulating damper is a single blade, round variation of a barometric relief damper. This is the simplest, most economical way of bypassing excess static pressure in multi-zone applications. Resistance is controlled by offering the arm and adjusting the weights. The arm can be inserted into either side of the damper for added versatility. SIZES: 8’, 10”, 12”, 14”, 16” Other sizes available upon request. mfr# size PRD-RD10 PRD-RD12
10” Round 12” Round
Zone Control Systems Model ST-2 Model ST series panels are for single stage heating and cooling with manual changeover. Zone 1 is the “master” zone which controls the heating and cooling mode and also the fan operation. The ST-2 is a 2 zone panel and the ST-3 is a 3 zone panel. Zones 2 and 3 will only operate in the same mode that the zone 1 thermostat is in. Each thermostat can turn the system “on” and “off ”, but only in the same mode. It is recommended the zones 2 and 3 have no switching subbases for the thermostats. The ST panels can be used with mechanical or digital programmable thermostats that are non-power stealing. Open-Close switches on the control panels near the damper terminal blocks allow for continuous air circulation. This switch controls the damper position when the heating and air conditioning system is at rest. The ST panels can be wired together or to the STLX panel to create larger zoning systems up to 11 zones. mfr# Description ST-2
Mini 2-Zone Control Panel
Zone Control Systems Models DMX-2, DMX-4, DMX-6, DMX-8 The DMX series of control panels were built with the installer in mind. This panel provides all the necessary features for a complete zoning system with the simplicity of a basic panel. The DMX is sold as a two, four, six or eight zone systems and is expandable. It is compatible with single stage, two stage and heat pump equipment and will control these with standard single stage thermostats. This feature is controlled by a timer built into the DMX that will bring on the second stage after 5 to 35 minutes, which is determined in the field. Another feature of the DMX is auto changeover from any zone. Any zone can call for heating or cooling at any time allowing for total comfort. The DMX has a field adjustable time of 2 or 3 and 31/2 min. For the purge time between a heating and cooling call. During this time the system will purge the air into the last calling zone with the fan running. After the purge time there will be an additional period where all dampers open and the HVAC equipment is at rest. This time period will be a total of 5 minutes including the purge. The most installer-friendly feature of the DMX panels is that it will work with virtually any 3 or 4 wire thermostat. This includes the new power stealing thermostats that have been less than 25 ma current draw. Each zone requires only 3 wires R-Y-W and an optional 4th wire G for fan control from any zone. Other installer-friendly features: • LED lights to show damper and system operation. • Automatic Reset fuse to protect panel from shorted wires. • Field selectable timer (0 to 60 min.) to control changeover to opposing call. • Built in Emergency Heat Switch. • Can use SAS for system protection mfr# Description DMX2
Zone Control System
4 grills / registers
8X8SMND 10X10SMND 12X8SMND 12X10SMND 12X12SMND 14X8SMND 14X10SMND 16X8SMND 16X10SMND 18X8SMND 18X10SMND 20X8SMND 20X10SMND 24X8SMND 24X10SMND
webb#
Grills / Registers
webb# 100277
webb# 99679
NCM
webb# 93993 153618
mfr# Description NCM300 3-Zone Control Panel
www.fwwebb.com
The F.W. Webb Heating Catalog
webb# 99691
F.W. Webb Company
23 3/23/08 8:20:56 PM
SECTION
4
Grills / Registers Parts & Accessories MAN/MA-5P
Thermostats
Two position, power open-power close actuator. Use with standard opposed blade dampers. (MAN).
EWT-DP Digital programmable thermostat for use on all zones on all series of control panels. Simple 5/2 programming. Battery powered (3 AA alkaline batteries required). mfr# Description EWT-DP-261 Digital/Programmable Thermostat
mfr# Description MAN
webb# 104693
A SPDT thermostat used for individual damper control or as zone thermostat on any ULTRA-ZONE control panel. Single stage, mercury switch. 3 wires required. Available in white.
EWT
3-Wire Mercury Thermostat
Monitors cooling coil tempeatures and protects agaianst coil freeze-up. Stops compressor below 37° and restarts above 47°. (Not adjustable) Mounts on a 3/4” suction line. mfr# Description CPLS
webb# 98411
TSB-M
Plate mounted 24V 40VA transformer for use with ULTRA-ZONE dampers and control systems. mfr# Description Plate Mounted Transformer
webb# 163845
Replacement relay for older style ULTRA-ZONE panels and the DTT series ULTRA-ZONE panels. mfr# Description RR
Plug In Replacement Relay
webb# 99402
SAS mfr# Description
6-Wire Subbase Heat/Cool Subbase
97594
Freeze Control
RR
6 wire subbase for use with EWT thermostat. Use this subbase for zone 1 system changeover on ST series ULTRA-ZONE control panels or any zone on all other control panels. Not for use for damper control without an ULTRA-ZONE control panel. Available in white.
TSB-M TSB-E351
webb#
T40-VA
T40-VA
mfr# Description
99765
Two Position Actuator
CPLS
EWT
mfr# Description
webb#
webb#
SAS
Supply Plenum Sensor
webb# 190375
98411 105530
F.W. Webb with WebbConnect™ allows you to: . figure jobs WebbConnect® . get pricing . order material 24 hours a day / 7 days a week!
24 4_Grills_Registers_p24.indd 24
F.W. Webb Company
www.fwwebb.com
3/23/08 8:21:04 PM
SECTION
5
Primary Controls Oil Primary Controls R7184 Interrupted Electronic Oil Primary
R7184
TIMING, mfr# description Safety Switch R7184A1026 Electronic Oil Primary 15 Seconds R7184B1024 Electronic Oil Primary with 15 second valve on delay 15 Seconds R7184U1004 Electronic Oil Primary with selectable valve and blower delays 15 Seconds R7184A1012 Electronic Oil Primary with selectable valve and blower delays 30 Seconds R7184A1034 Electronic Oil Primary 30 Seconds
webb# 216080 225220 247196 241963 360153
R8184G Protectorelay® Oil Burner Control Provides automatic, nonrecycling control of an intermittent ignition oil burner system. • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat. • Solid state flame sensing circuit. • LED on terminal strip indicates system lockout. • Manual trip lever opens safety switch for system maintenance. • C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required. TIMING, Saftey Switch 45 Seconds 15 Seconds 30 Seconds 45 Seconds
Includes — — — Alarm
webb# 31365 30882 54123 91415
HEATING CONTROLS
R8184G
mfr# R8184G4009 R8184G4066 R8184G4074 R8184G4082
5
R8184M Protectorelay® Oil Burner Control Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit. • Solid state flame sensing circuit. • Enclosed safety switch must be manually reset after safety shutdown. • R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment. • C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required. mfr# Timing, Safety Switch R8184M1051 45 Seconds
webb# 54121
R8184M
RA117 Protectorelay® Controls One-piece, stack mounted oil burner primary controls that cycle the burner on and shut down the burner on flame loss or system malfunction. • Combine a Protectorelay® unit for cycling the burner and a Pyrostat® flame detector for sensing temperature changes of flue gases up to 1000F. • Manual reset of safety switch required after ignition failure complestely shuts off main burner.
RA117
mfr# Ignition Type RA117A1047 Interrupted
The F.W. Webb Heating Catalog
5_HeatingControls_p40.indd 25
webb# 31367
F.W. Webb Company
25 3/23/08 8:39:56 PM
Primary Controls Primary Controls
SECTION
SECTION
5
5
Primary Controls Provide the advanced technology control your need for clean, efficient, reliable oilheat performance. Standard Features: • Interrupted ignition. • Limited reset. • Limited recycle. • Communication port. • Diagnostic LED. • Ambient range from –4-°F to +147°F. Advanced Features: • 15-second pre-purge. • Selectable post-purge. • Alarm contacts.
Models 40200-02, 42230-02 Electronic Oil Burner Primary Controls Features: • UL approved. • CSA Approved. • Interrupted duty operation. • Provides a 10 second ignition period after electronic flame detector circuit senses flame to prevent nuisance lockouts. • Provides 15 second safety switch timing (40200-02). • Provides 30 second safety switch timing (42230-02).
Model 48245 • 45 second safety switch timing with externally mounted manual reset button. • Bright red LED lamp indicates lockout condition.
Primary Controls
mfr# 7455U 7456U 7457U
Cadmium Sulfide Flame Detector Photoconductive flame sensing device for sequencing oil burner systems. • On flame failure, the light sensitive cadmium sulfide cell, in conjunction with flame sensing circuitry, causes the Protectorelay® control to shutdown the main oil burner. • Glass-to-metal hermetic seal in plug-in cell prevents deterioration by humidity, soot or oil fumes.
mfr# description Interrupted Duty Control 40200-02S 15 Seconds 42230-02 30 Seconds 48245-S 45 Seconds 50200-02S 15 Seconds With Alarm Contacts 60200002S 10 Seconds 6020002S015120 120 Seconds Post Direct Vent
26 5_HeatingControls_p40.indd 26-27
F.W. Webb Company
webb# 73839 111000 152935 153891 153892 194926
webb# 73254 82183
Cad Cell Eyes mfr# E81-5
description Type M For Honeywell, Blister Pack
webb# 69677
5
L4006 Aquastat® Controller Immersion type controllers for limiting or refulating temperatures of liquids in boilers/tanks. • Totally enclosed Micro Switch™ snap-acting switches operate on temperature rise to setpoint. • Visible control point scale and external adjustment screw permit easy setting. • Horizontal or vertical insertion of the sensing element. • Models available for strap-on mounting.
The Beckett GeniSys™ Advaned Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 Vac thermostat terminals compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15-second lockout time. Features and Benefits: • Thermostat and boiler control compatible. • Programmable valve-on delay and motor-off delay. • Three status lights for system monitoring and diagnostics. • Two communication ports for adding alarm contacts, programming display, and/or future wireless communications. • Welded relay protection with redundant motor relays. • Limited reset and limited. • Sleek, modern design. • Cad cell resistance indicator. • Technician Pump Prime mode. • 5 Year Warranty. Lockout VALVE-ON MOTOR-OFF mfr# TIME DELAY TIME2 DELAY TIME2 webb# 7505A 0000 15 Seconds — — 379489 7505P 1515 15 Seconds 15 Seconds 15 Seconds 379490 mfr# 52040U
description Alarm Module
Differential
Insulation Depth
Webb#
L4006A1009
5°F Fixed
11/2”
31352
L4006A1678
5°F to 30°F Adj. 3°C to 17°C Adj.
Mfr#
L4006
L4006A1959
Application
High Or Low Limit
Switching Action
SPST, Contacts Break On Temperature Rise
L4006A1967
L4006B1007
Circulator
L4006E1067
High Limit: Manual Reset
L4006H1004
High Limit: Strap-On Mounting On Well Mount
L6006A1145 L6006A1244 L6006C1018
Circulator Control and High Limit or Low Limit
SPST, Contacts Make On Temperature Rise
3”
2°F Fixed, 1°C Fixed 5°F to 30°F Adj. 3°C to 17°C Adj.
L4006A2007
30223
5°F Fixed 3°C Fixed
102322
11/2”
69620
3”
72981
11/2”
31353
3”
35044 110566
SPST, Contacts Break On Temperature Rise
Manual Reset
11/2”
SPDT
5 F to 30 F adj.
1½” - 3”
HEATING CONTROLS
• Interrupted duty, recycle type operation. • Latch-up feature after 3 consecutive lockouts. • Amber LED + Red LED indicates latch-up. • Self diagnostic test on each call for heat. • 1 second preignition. • Prepurge. • Postpurge. • 15 second trial for ignition. • Red LED solid on lockout indicator. • Alarm contacts close during lockout and latch-up.
description Cad Cell Eye With 30” Leads Cad Cell Eye With 60” Leads, 2 pc.
Single Function Aquastats
GeniSys™ Advanced Burner Control 7505
Model 60200-02
mfr# E80-1W E80-2W
Aquastats
description webb# R7184A1075 15 Seconds Safety 214258 R7184B1032 15 Seconds With Pre Purge 214259 R7184P1064 Pre Purge—Adj Post Purge 214260
Model 50200-02 • Interrupted duty, recycle type operation. • Latch-up feature after 3 consecutive lockouts. • Amber LED + Red LED indicates latch-up. • Self diagnostic test on each call for heat. • 1 second preignition. • 15 second trial for ignition. • Red LED solid on lockout indicator. • Red LED blinking recycle indicator. • Alarm contacts close during lockout and latch-up.
Cad Cell Kits
31356 72982 30224
webb# 379491
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
27 3/23/08 8:40:05 PM
SECTION
SECTION
5
5
Aquastats
Aquastats
Single Function Aquastats
Direct or Indirect Fired Storage Water Heater Temperature Controls
L4008; L6006 Remote Bulb Controller For limiting or regulating temperature of liquids in boilers or tanks. Can also sense duct or outside air temperature. • Remote temperature sensing element detects and responds rapidly to temperature changes. • Totally enclosed Micro Switch™ snap-acting switch. • Visible control point scale and external adjustment screw permit easy setting. • Horizontal or vertical mounting of the remote element into boiler, tank, or other container. Case mounts to a vertical surface.
EZ-Temp 90200 Microprocessor Temperature Controls • Microprocessor-operated. (Processor coordinates limit and diagnostic functions). • Easy remote sense. (Electronic sensors, wired to control). • Select from break-on-rise, make-on-rise or SPDT operation.
Mfr#
Application
Switching Action
Differential
Webb#
L4008A1015
High Or Low Limit
SPST, Contacts Brake On Temperature Rise
5°F To 30°F Adj.
105321
90200A Single Limit Temperature Control for Water Heaters
L4008E1156
High Limit: Manual Reset
SPST, Contacts Break On Temperature Rise
Manual Reset
30869
Single limit temperature control for direct fired storage water heater (and similar applications). One break-on-rise contact, single sensor.
SPDT
5°F To 30°F Adj.
101714
Install Pak—Includes temperature control, J-Box, immersion well (5.5” length),
Circulator Control And Low Limit
L4008
L6006A1192 L6006C1018
sensor and mounting hardware. UL Listed.
30224
Service Pak—Includes temperature control only. Replacement for Carlin Model 90200AL3S. UL Recognized.
L4103 Combination Aquastat and High Limit Controller ®
mfr# L4103A1019 L4103A1000
Temperature ratings 100°F To 240°F Stop Set At 150°F 100°F To 240°F Stop Set At 150°F
Insulation Depth 4” 21/4”
webb# 54128 30871
Direct Fired Storage Water Heater Temperature Controls • Serviceman reset protection. (Latch-up after three consecutive lockouts1) • Power-independent lockout. (Power cycling won’t reset from lockout or latch-up) • Diagnostic LED’s. (Power On, Call for Heat, and Lockout/ Latch-up) • SMC Technology2.
Dual limit (operating limit and manual reset high limit) microprocessor temperature control for direct-fired storage water heaters (and other similar applications). Two break-on-rise contacts in series (one for operating limit and one for high limit), single sensor.
Install Pak—Includes temperature control, J-Box, immersion well (5.5” length), single sensor and mounting hardware. UL Listed.
Service Pak—Includes temperature control only. Replacement for Carlin Model 900000BL1S. UL Recognized. Mfr#
28 5_HeatingControls_p40.indd 28-29
DESCRIPTION
OPER. TEMP. LIMIT (F)
HIGH LIMIT (F)
Webb#
90000BL1S
Dual Limit Control Install Pak
90°–160° / 8° Diff.
180° / 10° Diff.
379492
90000B1S
Dual Limit Control Only
90°–160° / 8° Diff.
180° / 10° Diff.
379493
F.W. Webb Company
DESCRIPTION
OPER. TEMP. LIMIT (F)
Webb#
90200AL3S
Single Limit Control Install Pak
120°–160° / 6° Diff.
379496
90200A3S
Single Limit Control Only
120°–160° / 6° Diff.
379497
5
Hot Water Boiler Temperature Controls Universal Dual Limit Temperature Control for Hot Water Boilers with Manual Reset
Install Pak—Includes temperature control, J-Box, immersion well (1.55” length),
Universal Dual Limit Temperature Control for Oil-Fired Water Heaters with Manual Reset
90000
Mfr#
Dual limit (operating limit and manual reset high limit) temperature control for hot water boilers (and other similar applications). Two break-on-rise contacts in series (one for operating limit and one for high limit), single sensor.
EZ-Temp 90000B Microprocessor Temperature Controls • Multiple sensor option (1 or 2). (Using individual and/or dual sensor assemblies) • Easy remote sense. (Electronic sensors, wired to control) • Smart manual reset. (Manual reset only if operating limit doesn’t open)
90200
HEATING CONTROLS
Immersion-type controller for oil-fired water heaters. Can also sense water temperature and cycles the burner through the oil primary. • L4103A has a sensing element and a high limit sensor with automatic reset. • Mounts on a horizontal immersion well in water heater wall. • Adjustable temperature setting scale. L4103
• Self-Checking program. (Control lockouts on diagnostic failure). • Diagnostic/status LED’s. (Power On and Call for Heat).
www.fwwebb.com
single sensor and mounting hardware. UL Listed.
Service Pak—Includes temperature control only. Replacement for Carlin Model 900000BL8S. UL Recognized. 90200D Single Limit Temperature Control for Hot Water Boilers Single limit temperature control for hot water boilers and or circulator control (and similar applications). One break-on-rise and one make-on-rise (SPDT) contact, single sensor.
Install Pak—Includes temperature control, J-Box, immersion well, sensor and mounting hardware.
Service Pak—Includes temperature control only. Replacement for Carlin Model 90200DL1S. Mfr#
DESCRIPTION
OPER. TEMP. LIMIT (F)
HIGH LIMIT (F)
Webb#
90000BL8S
Dual Limit Control HWB Install Pak
100°–200° / 15° Diff.
240° / 5° Diff.
379494
90000B8S
Dual Limit Control HWB Only
100°–200° / 15° Diff.
240° / 5° Diff.
379495
90200DL1S
Single Limit Control (SPDT) HWB Install Pak
50°–240° / 10° Diff.
379498
90200D1S
Single Limit Control Only (SPDT) HWB
50°–240° / 10° Diff.
379499
1) Latch-up mode shuts down the control after three consecutive lockouts, and requires a special procedure to reset. This ensures the owner will call in a licensed technician to troubleshoot and correct burner problems. 2) The 90000 provides two limit relays. Carlin’s patented SMC Technology (Safety Monitoring Circuit) monitors the contacts of both relays. Lockout occurs if a limit relay contact is found closed when it should be open.
The F.W. Webb Heating Catalog
F.W. Webb Company
29 3/23/08 8:41:09 PM
Aquastats
SECTION
SECTION
5
5
Aquastats
Multi-Function Aquastats L4081 Multiple
Aquastat®
Multi-Function Aquastats
Controllers
L8148 Aqaustat® Relay
High limit, low limit and/or circulator controllers used to regulate boiler water temperature in gas- or oil-fired hydronic heating systems. • Immersion type, liquid-filled sensing element actuates two snap switches. • Controller may be mounted in any position and does not require leveling.
L4081
Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors. • Include transformer and accessory terminals for adding a remote low limit controller.
MFR#
APPLICATION
SWITCHING ACTION
DIFFERENTIAL
WEBB#
L4081A1023
High Or Low Limit
SPST, High & Low Limit
High Limit: 10°F Fixed Low Limit: 10°F - 25°F Adj.
31355
L6081A1010
High Or Low Limit, High Limit and Cirulcator
SPST, Contacts Break On Temperature Rise
10°F Fixed
31358
L7224U Universal Oil Electronic Aquastat® Controller
mfr# L7224U1002
description Universal Oil Electornic Aquastat Controller
webb# 213990
L8124 Triple Aquastat® Relay Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems. Including domestic hot water service. • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems. • Mount directly to boiler. MFR#
L8124
VOLTAGE
INSULATION DEPTH
mfr# DESCRIPTION 3150 HydroStat™ Control
5
webb# 379324
EW201 EW202 EW221
3/4” STD Electro-Well™ 1/2” STD Electro-Well™
379325 379326 379327
48-101 48-102
Remote Mnt Kit 24” Remote Mnt Kit 24”
379328 379329
3/4” Long Electro-Well™
Combination Controls Aquastat, Multi-Function — Aquastat and Oil Primary
WEBB#
L8124B1039
30873
R8182 Combination Protectorelay® and Hydronic Heating
L8124C1003
67707
Immersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems. • Use in intermittent Ignition applications. • Capable of zone control with zone valves. • Flame failure during the running cycle results in a 45 second attempt to restart. If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted. • C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required.
L8124A1015
L8124L1011
120 Vac
11/2”
101738 11771 11771
24 Vac/120 Vac
3”
31359
L8151 Triple Function Aquastat® Relay Combines high limit protection with low limit and circulator control for use in hydronic heating systems that include domestic hot water service. • Provides multizone control by using a separate thermostat and R845 Relay for each zone. • Includes internal transformer to power a 24 Vac thermostat (heat anticipator set at 0.2A). • Shielded capillary allows convenient mounting.
5_HeatingControls_p40.indd 30-31
• Replaces Cold Start and Triple-Action Aquastats® • Install it on existing immersion well for full temperature functionality, or • Install it on an Electro-Well™ to add low water cut-off protection. • Simple dial-type temperature and differential settings. • Easy to wire - uses the same terminal designations as common Aquastat models. • Dynamic Temperature Display. • Four on-board diagnostic indicating lights. • Saves time, materials and wiring.
30872
L8124G1020
30
HYDROLEVEL HydroStat™ Model 3150 COMPANY Universal Temperature Limit and Low Water Cut-Off for Oil Fired Boilers
L8124A1007
L8124E1016
L8151
webb# 30874 76220 31360
HEATING CONTROLS
L7224
The L7224U Controller provides electronic temperature sensing in a UL limit-rated control with a single sensing probe. The L7224U controls circulator, oil burner and boiler temperature. The L7224U replaces the L8124A, L8124C and L8148A Controllers. • Universal control for oil-fired boilers. • Communications port for future field added advanced feature modules. • Mounts either horizontally or vertically, directly on the boiler. • Adjustable low limit differential. • Replaceable fuse emitting diodes (LED). • Mounts on standard 1/2” (13 mm) or 3/4” wells. • Replaceable relays. • Provides multizones control with • Separately replaceable sensor, used in separate circulators and R845 Relays or conjunction with the L7142U, produces a R888 Zone Relay Panel. limit rated system. • Low limit disable.
L8148
mfr# Differential Operating Range, High Limit L8148A1017 8ºF Fixed 120ºF To 240ºF L8148E1265 15ºF Fixed 180ºF To 240ºF L8148J1009 8ºF Fixed 140ºF To 240ºF
mfr# L8151A1052
Voltage 120 Vac
F.W. Webb Company
webb# 72987
www.fwwebb.com
MFR# R8182D1079
Mounting
Operating Range, High Limit
High Limit; 10°F Fixed; Low Limit/Circulator; 10°F To 25°F Adj.
130°F to 240°F Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay
Vertical
R8182D1111
Horizontal
R8182H1070
On Junction Box
The F.W. Webb Heating Catalog
Differential
F.W. Webb Company
WEBB# 69622 31363 30881
31 3/23/08 8:41:27 PM
SECTION
SECTION
5
5
Combination Controls
Fan & Limits
Aquastat Wells
Snap Disk Controls Snap Disk Fan Controls
Sturdy brass and copper construction for long service life. mfr# Description PMW2S 1/2” Well Assembly PMW3S 3/4” Well Assembly
webb# 55512 55513
mfr# Description PMW3SE 3/4” Long Well Assembly 1213712 1/2” Long Well Assembly
Types for regulation of fan or blower or for high limit safety control.
webb# 31377 86211
MFR# 3F02-125
Pressuretrols 3F02-125
Mercury-Free Pressuretrol® Controller
L404F
• 1/4” IPS. • 600 PSI-750°F.
mfr# Description 2740101 1/4” Straight Brass Pigtail 2740201 1/4” Angle Brass Pigtail 1459 1/4” Straight Pigtail 1460 1/4” Angle Pigtail
3L05-1
webb# 54177 54178 75631 75632
Fan or Limit Controls Provides high limit protection for warm air furnaces or controls blower operation. Features: • Interchangeable with competitive makes. • Limit control has “universal” contacts capable of handling millivolts to 240 Vac. • Limit control equipped with adjustable stop to limit setting. Shipped to 200°F. • U.L. recognized and C.S.A certified.
Fan & Limit Controls
Fan Types Without Enclosure
L4064B Fan & Limit Controllers 5C02-1
For control of high limit and fan motor in all types of forced air heating systems. Element Insertion Length
L4064B2210 L4064B
Fan On
Fan Off
65°F To 215°F
50°F To 200°F
Mounting
11/2”
L4064B2228
5”
L4064B2236
8”
Surface
WEBB#
Limit Types Without Enclosure
54125
Range Differential Element SWITCH MFR# (Degrees) (Degrees) Length Action 5C02-1 150°F To 250°F Fixed 25°F 3” Open On Rise 5C02-51 150°F To 250°F Fixed 25°F 7” Open On Rise
54126
Integrates control of combustion blower and circulating fan operations in a gas warm air appliance. Integrates control of burner and circulating fan operations in an oil furnace.
ST9103A1002
32 5_HeatingControls_p40.indd 32-33
HEAT FAN OFF DELAY
COOL Fan ON DELAY
COOL FAN OFF DELAY
AMBIENT TEMPERATURE RANGE (F)
WEBB#
Field adj. 30 or 60 sec.
Field adj. 60, 100, 140 or 180 sec.
Field adj. 4 or 30 sec.
Fixed 30 sec.
–40° F to +160° F
362719
Fixed 0 sec.
Fixed 0 sec.
–40° F to +150° F
110788
Adj. 60, 90, 120, 150 Adj. 60, 90, 120, 150 (set at 150 sec.) 50/60 Hz (set at 150 sec.)
F.W. Webb Company
www.fwwebb.com
webb# 74494 187898
webb# 74495 188190
Ideal for replacement of similar type controls. Features: • Particularly well suited for use where space limitations are a problem. • Small bimetal sensing element is completely in air stream to give quick response. • Fan control has adjustable range with direct reading temperature dial. • Limit has adjustable cut-out setting.
ST9103 Electronic Fan Timers HEAT FAN ON DELAY
5
Flush Mount Fan or Limit Controls
ST9101; ST9141 Electronic Fan Timers
ST9120U1003
Range Cut-Out Differential Element SWITCH MFR# (Degrees) (Degrees) Length Action 5C22-2 70°F To 125°F Adj. 25°F To 50°F 3” Close On Rise 5C22-52 70°F To 125°F Adj. 25°F To 50°F 7” Close On Rise
69621
Electronic Fan Timers
MFR#
Temperature Range Differential Switch MFR# (Degrees) (Degrees) Action Function webb# 3F05-4 140°F To 180°F 20°F SPST Fan Control (Close On Rise) 188188 3L05-1 135°F To 175°F 40°F SPST Limit Controls (Open On Rise) 119139 3L05-6 210°F To 250°F 40°F SPST Limit Controls (Open On Rise) 188189
Warm Air Controls
Fan & Limits / Electronic Fan Timers
MFR#
Adjustable Snap Disc Fan and Limit Controls
HEATING CONTROLS
Pigtail Siphons
webb# 187892
This adjustable snap disc thermostat allows you to set the temperature set point to match your specific needs which simplifies inventory. Features: • 1/4” quick disconnect terminals are standard. • Replaces the majority of fixed disc thermostats now on heating equipment and various appliances.
Residential Pressure Control Provide control for steam pressure. Adjustable Operating • Sensitive pressure-actuated diaphragm mfr# pressure range webb# expands or contracts with pressure L404F1060 2 psi - 15 psi 31361 variations, moving a lever machanism L404F1367 1 psi - 8.0 psi 31362 that operates the snap-switch. • Use L404F as high limit safety controller for steam boilers. • Contain SPST snap-acting switch. • Adjust setpoint without removing the cover. • Set differential using a dial located inside the case.
Fixed Temperature settings Switch Heater Cut-In Cut-Out Action Voltage 125°F Adjustable Close On Rise 24 Vac
757-1
Range Differential SWITCH MFR# Description (Degrees) (Fixed Degrees) Action 757-1 Fan 70°F To 160°F 25°F Close On Rise 758-1 Limit 110°F To 200°F 25°F Open On Rise
The F.W. Webb Heating Catalog
F.W. Webb Company
webb# 119137 119138
33 3/23/08 8:42:00 PM
SECTION
SECTION
5
5
Switching Relays
Fan Centers & Contactors
Hydronic Switch Relay
General Purpose Relays
RA89, RA832, R845 Hydronic Switching Relay
Provide general purpose switching for air conditioning equipment. • Molded terminal numbers and circuit diagram on top of relay provide easy identification for wiring and checking system operation. • Base designed for easy replacement of competitive relays. • Plug compatible with Steveco 90-340 and Mars 90340.
• Provide intermediate switching of a line coltage device from a low voltage controller. • Integral transformer provides low voltage power for control circuit. ELECTRICAL RATINGS, mfr# APPLICATION PRIMARY VOLTAGE RA89A1074 For switching one line voltage load 120V RA832A1066 For switching two line voltage loads having a common power source 120V R845A1030 One pole line voltage, the other line or low voltage 120V
RA89
webb# 30226 30227 30225 R8222
Circulator Switching Relays SR501
Taco Switching Relays combine clearly labeled PC board layouts with advanced features that allow for total system customization. External indicator lights provide instant diagnostic feedback, making a snap of service calls or new installation start-ups. All switching relays are UL and CSA listed, use standard “ice cube” replaceable relays, and are compatible with conventional and programmable thermostats. EXP Switching Relays can be expanded up to 20 zones with priority. Taco Switching Relays are available in one, two, three, four, and six zones. Switching Relays
SR504-EXP
Plug-In PowerPort Cards
PC600
mfr# Description webb# PC600 Post Purge Timer Plug-In Card For EXP Relay 190583 PC605 Priority Protection Plug-In Card For EXP Relay 190584 PC610 Universal Timer/Pump Exercise Plug-In Card 190585
R8225 Fan Relay Provide general purpose switching for air conditioning equipment. • Molded terminal numbers and circuit diagram on top of relay provide easy identification for wiring and checking system operation. • Base designed for easy replacement of competitive relays. • Plug compatible with Steveco 90-340 and Mars 90340.
Switching Relays with PowerPort Options mfr# Description webb# SR501-EXP 1 Zone Circulator Relay With Priority & 3 Powerports 368218 SR503-EXP 3 Zone Circulator Relay With Priority & 3 Powerports 179537 SR504-EXP 4 Zone Circulator Relay With Priority & 3 Powerports 179738 SR506-EXP 6 Zone Circulator Relay With Priority & 3 Powerports 179739
COIL RATINGS VOLTAGE WEBB# 24 Vac 54120 24 Vac 69623 120 Volt 66708 208/240 Volt 103218
R8225
MFR# SWITCHING R8225A1017 SPDT
5
COIL RATINGS VOLTAGE WEBB# 24 Vac 35050
HEATING CONTROLS
mfr# Description webb# SR501 1 Zone Circulator Relay 179522 SR502 2 Zone Circulator Relay With Priority 179523 SR503 3 Zone Circulator Relay With Priority 179524 SR504 4 Zone Circulator Relay With Priority 179536 SR506 6 Zone Circulator Relay With Priority 179525
MFR# SWITCHING R8222B1067 SPDT R8222D1014 DPDT R4222D1013 DPDT R4222D1021 DPDT
Fan Center R8239 Control Center
Add-On Power Controls
Include NEMA standard transformer for excellent voltage control. Provide low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or heatingcooling circuits. • Convenient connections for thermostat, and heating-cooling equipment wiring. • Mount on standard 4 x 4 junction box.
mfr# Description webb# PC700 Boiler Reset Control for EXP Relay 191074 PC702 Two Stage Boiler Reset Control For EXP Relay 255596 PC705 Variable Speed Pump Injection Control 192529
Application
Power Supply
R8239A1052
For single- or two-speed fan
40 VA
120 Vac
R8239B1076
For system with F50 Electronic Air Cleaner humidifier and blower motor
50 VA
120 Vac 208 Vac 240 Vac
Mfr#
R8239
Primary Secondary
SWITCHING ACTION Webb#
26.5 V
SPDT
72904
DPDT
98528
Electronic Controls Replacement Parts PC700
mfr# Description SR120-001RP 120 Volt Relay Replacement Cube SR024-001RP 24 Volt Relay Replacement Cube
R8285 Control Center
webb# 189579 189580
Provides low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling, or air conditioning systems. • Low voltage terminal board provides convenient connections for thermostat and heating/cooling equipment wiring. • Mounts on standard 4” x 4” junction box.
Air Handler Controls mfr# Description HAFC201 Fan Control With Time Delay HAFC101-1 Fan Control
34 5_HeatingControls_p40.indd 34-35
F.W. Webb Company
Mfr#
webb# 245500 189578
R8285
www.fwwebb.com
Application
R8285A1048 For single- or two-speed fan
The F.W. Webb Heating Catalog
Power SWITCHING Supply Primary Secondary ACTION Webb# 40 VA
120 Vac
26.5 V
F.W. Webb Company
SPDT
105673
35 3/23/08 8:42:39 PM
SECTION
SECTION
5
5
Low Voltage Transformers
Heat Manager
24 Volt General Purpose Transformers
Heat Manager
AT140A, AT150A, AT175A General Purpose
7512
Provide power to 24 Vac circuits in heating/cooling control systems. Intended for use in systems with predictable, uniform loads. Can be used in any application that does not exceed the listed ratings.
Mfr#
AT140
Electrical RaTings Primary Voltage
AT140A1000
120V
AT140A1018
120V 208V 240V
AT150A1007 AT175A1008
Electrical Connections Primary
Secondary
Mounting
(2) Screw Terminals
Foot-mounted, plate-mounted on 2 X 4” or 4 X 4” outlet box, clamp-mounted using outlet box knockout, or panel-mounted.
9” Lead Wires, 40 VA 9” Lead Wires, 50 VA 9” Lead Wires, 75 VA
Webb# 35059 98623 96118 94775
AT150F, AT175F Circuit Breaker Transformer Electrical Ratings Mfr#
Output
AT150F1022 24 V At 50 VA AT175F1023 24 V At 75 VA AT150F1030
24V At 75 VA
7512
Electrical Connections
mfr# 7512
Webb#
120V 208V 240V
9” Lead Wires
9” Lead Wires
191283
9” Lead Wires with all lead wires through conduit screw
9” Lead Wires with all lead wires through conduit screw
191284
Gas Boiler Heat Manager
9” Lead Wires
9” Lead Wires
244103
Designed specifically for gas boilers. Its action is similar to outdoor reset method, but does not require an outdoor sensor. Heat manager works with the existing boiler control/Aquastat™ to reduce fuel consumption, wear on parts, and flue emissions.
208V 277V 480V
9” Lead Wires with all lead 9” Lead Wires with all lead wires through conduit screw wires through conduit screw
Electrical Electrical Connections RaTings Primary Voltage Primary Secondary
120V
210651
Mounting
Webb#
9” Lead Wires
(2) Screw Terminals
4 X 4” plate-mounted protruding into junction box
98600
9” Primary Lead Wires Through Plate
9” Secondary Lead Wires through plate
4 X 4” plate-mounted without protruding into junction box
100749
(2) Screw Terminals
Foot mounted; Plate mounted on 4” X 4”, 4” octagon, or 2” X 4” electrical boxes (transformer all above plate or 3/4 above plate); or clamp mounted via a juntion box knockout
AT72D1683
AT72
AT72D1691
208V 240V With 40VA Output Rating
webb# 268686
Secondary
• • • • • •
24V control circuit step-down transformer designed to power any 24V control system, including thermostats, gas valves and relays.
AT72D1188
description Beckett Heat Manager
Primary
AT72 NEMA Standard Transformer
AT72D1006
Improves overall heating system efficiency. Guaranteed to reduce heating fuel consumption 10–20%. Reduces boiler on/off cycles by up to 30%. Reduces wear and tear on boiler and components. Works with any fuel. 15–30 minute installation.
Primary Voltage
24 Volt NEMA Rated Transformers
Mfr#
• • • • • •
9” Lead Wires
5 HEATING CONTROLS
AT175F1031
AT150
24V At 50 VA
HeatManager is a microprocessor controlled fuel economizer for residential boiler heating systems. HeatManager automatically adjusts burner firing patterns and average boiler water temperature to match system heat load. Its action is similar to outdoor reset method, but does not require an outdoor sensor. Heat manager works with the existing boiler control/ Aquastat™ to reduce fuel consumption, wear on parts, and flue emissions.
Improves overall heating system efficiency. Guaranteed to reduce gas consumption for heating 10–20%. Reduces boiler on/off cycles by up to 30%. Optimized for cold-start gas boilers. Reduces wear and tear on boiler and components. 15–30 minute installation.
mfr# 7550U
description PurePro Gas Heat Manager
webb# 356228
mfr# 7518
description Temperature Sensor For 7512, 7550U
webb# 268687
7550U 30222 107255
AT87 NEMA Standard Transformer Used primarily for powering 24V air conditioning circuits. Can also be used in other applications that do not exceed the listed ratings. • Meets “NEC Class 2 not wet. Class 3 wet” and UL 1585 requirements. • Meets NEMA Standard DC20-1992.
Mfr#
AT87
36 5_HeatingControls_p40.indd 36-37
Electrical Electrical Connections RaTings Electrical Primary Ratings Voltage Primary Secondary output
AT87A1106
120V, 208V 240V
AT87A1155
480V
AT87A1189
277V
F.W. Webb Company
Mounting
Webb# 35059
13” Leads
(2) Screw Terminals
24 V At 50 VA
Foot-Mounted or 4” X 4” plate
12” Lead Wires
12” Leads
24 V At 48 VA
Foot-Mounted
F.W. Webb with WebbConnect™ allows you to: . figure jobs ® WebbConnect . get pricing . order material 24 hours a day / 7 days a week!
98962 99404
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
37 3/23/08 8:43:56 PM
Boiler Reset
SECTION
5
5
Boiler Reset
One Stage Setpoint Control
Boiler/DHW Controls (cont.)
150
264 Four Stage Boiler Control
The One Stage Setpoint Control 150 is a microprocessor-based control with a digital display and a remote sensor. The 150 has an extremely wide setpoint range and is accurate to within +-0.5째F. Pulse width modulation control logic is provided for slow responding systems. Either heating or cooling systems can be controlled through the SPDT output relay.
The Four Stage Boiler Control 264 is a microprocessor-based four stage boiler control. The 264 stages and has Equal Run Time Rotation of the boilers and also operates the system pump. Single burner or Lo-Hi fire boilers can be rotated. A single high efficiency front end boiler can also be used with the fixed lead option. A Tekmar Indoor Sensor or Zone Control can be connected to the 264 in order to provide Indoor Temperature Feedback from single or multiple zones.
mfr# 150 150
SECTION
description 1 Stage Setpoint Control
webb# 214639
264
Boiler/DHW Controls
mfr# 264
description 4 Stage Boiler Reset Control
webb# 214642
256 One Stage Boiler 268 Eight Stage Boiler Control
The Boiler Control 256 is a microprocessor-based control designed to regulate the supply water temperature from a single boiler based on the outdoor temperature. To avoid boiler short cycling and large temperature swings, the 256 is able to continuously adjust the boiler differential. The 256 includes control functions such as Warm Weather Shut Down (WWSD) and Minimum Boiler setting. The control has a liquid crystal display (LCD) that normally displays the Boiler Supply temperature, but can display other temperatures and settings. 256
mfr# 256
description 1 Stage Boiler Reset Control
The Eight Stage Boiler Control 268 is a microprocessor-based eight stage outdoor reset control with a built-in night setback timer and digital display. The 268 can stage and rotate single burner boilers or Lo/Hi fire boilers. A combustion air damper relay is also provided. Base loading of multiple boilers onto an existing inefficient boiler can be accomplished through a Fixed Last option. A single high efficiency front end boiler can also be used with a Fixed Lead option.
webb# 214641 268
mfr# 268
description 8 Stage Boiler Reset Control
webb# 214643
360 Mixing Control Floating Action
The Boiler Control 260 is a microprocessor-based control designed to regulate the supply water temperature from a single boiler based on either outdoor air temperature or a DHW demand. The 260 can control either DHW pump or valve and provide DHW Priority. A Tekmar indoor sensor can be connected to the 260 in order to provide indoor temperature feedback from the heating system. 260
mfr# 260
description 1 Stage Boiler/DHW Reset Control
The Mixing Control 360 is a microprocessor-based outdoor reset control designed to operate a 24 floating action 2, 3, or 4-way valve. The 360 also provides for boiler minimum protection, system pump operation, an operation. As well, a tekmar indoor sensor can be connected to the control to provide indoor temperature feedback.
webb# 210840
mfr# 360
description Floating Action Mixing Control
webb# 283490
HEATING CONTROLS
260 One Stage Boiler & DHW
5
261 Two Stage Boiler & Setpoint The Boiler Control 261 is a microprocessor-based two stage boiler designed to regulate the supply water temperature from a single two stage boiler or two single stage boilers based on either outdoor air temperature of a setpoint demand. The 261 can stage and rotate two single fire boilers or is can stage a single Lo/Hi fire boiler. The 261 also operates the system pump. 261
mfr# 261
description Dual Boiler Control
Stand Alone Heating Controls 363 Universal Reset Control Mixing, Boiler & DHW
webb# 255401
262 Two Stage Boiler & DHW/Two Stage DHW The Boiler Control 262 is a microprocessor-based boiler outdoor reset control that has two modes of operation. Mode 1 operates as two stage boiler and DHW, and mode 2 operates as two boilers or Lo/Hi fire boiler for DHW applications. A Tekmar Indoor Sensor, Digital RTU, or Zone Control can be connected to provide indoor temperature feedback from single or multiple zones. An optional Remote Display Module 040 and DHW indirect sensor can also be added. 262
38 5_HeatingControls_p40.indd 38-39
mfr# 262
description 2 Stage Boiler/DHW Reset Control
F.W. Webb Company
363
The Universal Reset Control 363 is a microprocessor-based control capable is providing both a reset boiler supply temperature and a reset mixed supply temperature based on outdoor air temperature. For a mixing device, the 363 can use either a variable speed injection pump or a floating action mixing valve. The 363 is also capable of controlling an indirect Domestic Hot Water (DHW) storage tank and/or a setpoint load. Individual zone temperature control can be achieved by using either a conventional thermostat system, or by connecting a Tekmar Zone Control(s) to the 363. mfr# 363
description Universal Boiler Reset Control
webb# 245725
webb# 214640
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
39 3/23/08 8:44:19 PM
SECTION
5
Boiler Reset Miscellaneous 132 Pump Sequencer Stand-by / 2-Stage
The Pump Sequencer 132 is a micro processor-based control intended for either stand-by or two stage pump operation. The 132 includes features such as equal run time rotation, exercising, and warm weather shut down (WWSD). As well, the 132 offers two separate alarm contacts to indicate pump failures. mfr# 132
description Pump Sequencer
webb# 245724
132
Sensors 080 Universal Sensor Enclosure
The Universal Sensor Enclosure 080 is designed for mounting a universal sensor either into a standard 3/8” I.D. well, or strapped onto the surface of a 1” to 4” diameter pipe. The end of the enclosure has a knock out to connect 1/2” conduit. 080 Universal Sensor Enclosure 071 Universal Sensor mfr# description 080 Universal Sensor Enclosure 070
webb# 214649
070 Outdoor Sensor mfr# description 070 Outdoor Sensor -60 to 140°F
mfr# description webb# 071 Universal Sensor -60 to 255°F 214647
076 Indoor Sensor webb# 214646
mfr# description 076 Indoor Sensor -60 to 140°F
Room Temperature Units
071
054 Room Temperature Unit mfr# description 054 Room Temperature Unit
webb# 214648
webb# 214645
076
054
Thermostat Programmable Thermostat 510 — One Stage Heat
The 510 is a microprocessor-based thermostat intended for one stage heating applications. The 510 allows for up to two auxiliary sensors. The auxiliary sensors can be used to measure air temperature to get an average temperature for large areas. The auxiliary sensors can be used to measure slab temperature in order to limit the minimum and/or maximum allowed slab temperature. Or the auxiliary sensors can be used to display the outdoor temperature and/or a remote temperature. Indoor use only, 32 to 122° F mfr# 510
description 1 Stage Programmable Thermostat
webb# 264609
tekmarNet® 4 Thermostat 541 — One Stage Heat
The tekmarNet® 4 thermostat 541 operates one stage of heating equipment. The 541 can operate as alone device, or communicate with a group of tekmarNet® 4 thermostats. Indoor use only, 32 to 122° F mfr# 541
40 5_HeatingControls_p40.indd 40
description 1 Stage tekmarNet 4 Thermostat
F.W. Webb Company
webb# 310358
www.fwwebb.com
3/23/08 8:44:28 PM
SECTION
6
Expansion Tanks & Accessories Fill-Trol • Provides accurate system make up. • Eliminates need for a separate automatic fill valve. • Fully adjustable up to a maximum working pressure of 100 psig. • Factory pre-charged to 12 psig.
Boiler Trim Packages Each PurePro® Boiler Trim Kit gives you everything you need for a quality boiler installation. Each kit includes a Micro Bubble Air Eliminator or Air Purger/ Air vent, Expension Tank, Boiler Fill/Backflow Preventer, and two Service Check Valves. It is so complete we even include the nipples! PurePro® Boiler Trim Kits are the only trim packages that give you a mix of the leading manufacturers to give you the product brand you prefer in a single easy-to-carry box. mfr# PPBTK-ISTD PPBTK-114STD PPBTK-IDLX PPBTK-114DLX
mfr# Description Webb# 109 2 Gal. 147 110 4.4 Gal. 148
Fill-Trol Valve Repair Kit mfr# 109-15
Amtrol Minitrol Arrestor mfr# Description Webb# 500 1/2 MPT 164
Description Webb# PurePro® 1” Standard Boiler Trim Kit 316483 PurePro® 11/4” Standard Boiler Trim Kit 316484 PurePro® 1” Deluxe Boiler Trim Kit 316485 PurePro® 11/4” Deluxe Boiler Trim Kit 316486
• Diaphragm-type. • Butyl diaphragm material. • Pre-pressurized expansion tank. • Designed for close-loop hydronic heating systems. • Provides separation of system water from air cushion. mfr# 15 30 60 90
mfr# Description Webb# ST5 2 Gal. 53629 ST12 4.4 Gal. 53630
mfr# SX30V SX40V SX60V SX90V
Tank Vol. 14 Gal. 20 Gal. 32 Gal. 44 Gal.
Webb# 120 121 122 123
Flexcon Expansion Tanks HT Series Vent# 700-C 700-C 700-C
See page 282 for Cross Reference information.
6_Hydronics-Steam_p83.indd 41
6
• Operating Temperature: 240°F. • Working Pressure: 100 psig.
Extrol Combination Packages
The F.W. Webb Heating Catalog
• Diaphragm-type. • Pre-pressurized expansion tank. • Designed for potable hot water systems. • Eliminates relief valve spills. • Control pressure build-up. • Protects plumbing fixtures. • Extends water heater life. • Eliminates hot water waste.
SX Series
Description Webb# 2 Gal. 116 4.4 Gal. 117 7.6 Gal. 118 14.0 Gal. 119
Mfr# FILL-Trol# Purger# 3000-1 30 443 OR 444 3000-114 30 443 OR 444 6000-114 60 444
Therm-X-Trol
Hydronics/steam
Expansion Tanks
Extrol
Webb# 72184
Webb# 127 30064 128
Constructed with time tested clench ring technology, HT tanks feature butyl diaphragms engineered for longer life. Butyl rubber is the material of choice for American heating systems as it offers low permeability rates at higher temperatures. Our symmetrical tank and diaphragm shape maximizes tank drawdown, and minimizes diaphragm wear. mfr# 15F 30F HTX60
Description Webb# 2 Gallon 34480 4 Gallon 34483 7 Gallon 34484
F.W. Webb Company
41 3/23/08 8:55:18 PM
SECTION
SECTION
6
6
Expansion Tanks & Accessories Air Scoops Mfr# 431F 432F 433F 434 435
Description 1” 11/4” 11/2” 2” 21/2”
Accessories 3 Ply – Nylon Vinyl – Braided Retains full flexibility down to 0°F. mfr# 531
Vortech Air Separators The Taco Vortech Air Separator is designed to provide an enhanced level of air removal in hydronic heating, cooling or combination systems. Air is quickly and effectively separated and vented through a factory installed Taco 3/4” Hy-Vent. Mfr# VRTX100-1 VRTX125-3 VRTX150-1 VRTX200-1
Description 5/8” X 50’
Description 6’
Air Vents Spirovent
Junior Microbubble™ Separator mfr# Desc. 443 1” 444 11/4” 445 11/2” 446 2”
Mfr# “A” 443 1” 444 11/4” 445 11/2” 446 2”
“B” 4” 4” 5” 6”
“C” 21/2” 21/2” 31/2” 31/2”
Mfr# “U” 443 1” 444 11/4” 445 11/2” 446 2”
F.W. Webb Company
The Spirovent® Air Eliminator employs a patented Spirotube® coalescing medium that “scrubs” the air from the system fluid. Simple to install with a straight in-line design it is available in the Junior Series for residential and light commercial applications. Solid brass construction, integral patented air release mechanism and a 20 year limited warranty.
Webb# 131 132 133 134
Tappings (NPT) Ins.
Dimensions
®
“V” 1/8” 1/8” 1/8” 1/2”
Spirovent® Junior
“Z” 1/2” 1/2” 1/2” 1/2”
6
mfr# description webb# 34JR VJR– 075FT, 3/4” Brass 68419 1JR VJR– 100TM, 1” Brass 67312 114JR VJR– 125TM, 11/4” Brass 67313 112JR VJR– 150TM, 11/2” Brass 68420
Spirotop® Air Release Valve The Spirotop® Air Release Valve is essentially the vent head used on all products through 12”. It has a 1/2” bottom connection and can be used in places where other float vents have been used. Carries a 20 year Limited Warranty and is designed not to leak by means of a dry air chamber. Spirotop®
mfr# description webb# 12TOP VTP– 050FT 79701
Hydronics/steam
Mfr# Description Webb# 440-2 1/2” Tank Drainer with Shutoff Valve 24913
6_Hydronics-Steam_p83.indd 42-43
mfr# description webb# B911S-12 Bronze 1/2” Solder 58518
PV Series SuperVent™ Air Eliminator The unique design of the Honeywell PV Series SuperVent™ breaks apart air bubbles, absorbs stagnant air pockets and eliminates troublesome air from hydronic heating systems.
Webb# 361140 361139 361138 361137
Tank Drainer
42
Webb# 72329
mfr# description webb# 9DSM3-12 1/2” Solder 28643 9DM3-12T 1/2” Threaded 73896 9DM2-34 3/4” Threaded 28644
Air Purgers
Air Separator The Taco 4900 Series Air Separators are designed for the complete elimination of air from closed loop heating and cooling systems up to a maximum temperature of 240°F and a maximum pressure of 150 psi. Features: • Patented PALL ring design. • Eliminates air induced system noise. • Minimal pressure loss. • Vent can be closed. • Large surface contact area. • Protective vent plate. • Rugged dependability. • Maximum air removal. • Convenient expansion tank connection tapping. • No minimum run of pipe requirement. • Bidirectional flow.
Dual check backflow preventer with atmospheric vent for continuous pressure.
• Used on boiler supply feed lines to provide make-up water to the boiler and prevent backflow when supply pressure falls below system pressure. • An assembly of Watts 9D Backflow Preventer and 1156ºF feed water pressure regulator.
Webb# 74790
Washing Machine Hose mfr# 298002
Backflow Preventers
Series 911 For hot water boilers
• ASME construction. • 125 psig working pressure. • Tangential type air separator.
Description Webb# 1” 194008 11/4” 194009 11/2” 194011 2” 194012
Mfr# Description 49075T1 3/4” Air Separator 49100T1 1” Air Separator 4900125T1 11/4” Air Separator 49150T1 11/2” Air Separator
Combination Backflow Preventor & Fill Valve
Reinforced Garden Hose
Webb# 34492 34493 34494 24907 24908
Backflow Preventers
F.W. Webb stocks burnham heating products! www.fwwebb.com
MODEL# SIZE Connection type webb# PV075 3/4” NPT 359554 PV075S 3/4” Sweat 359555 PV100 1” NPT 90568 PV100S 1” Sweat 359556 PV125 11/4” NPT 90569 PV125S 11/4” Sweat 250734 PV150 11/2” NPT 318442 PV200 2” NPT 262124 PV-001RP Replacement Air Vent Assembly 372144
The F.W. Webb Heating Catalog
F.W. Webb Company
43 3/23/08 8:55:25 PM
SECTION
SECTION
6
6
Air Vents DuoVent High Capacity Air Vent with Manual Vent Feature Provides automatic air venting for hot or cold water distribution systems. Features: • Body and cover are brass construction. • Air vent with silicone rubber seal. • Suitable for use with glycol systems. mfr# description webb# 590719 1/8” DuoVent Air Vent 13699
Varivents mfr# description webb# ANG 925005 Angle 78959 STR 925006 Straight 78960
Float Type Air Vents • Rugged cast bronze body. • Compact size to fit the smallest spaces. • Serviceable design – take apart feature. • Improves system efficiency.
Dole® Flow Regulator
mfr# description webb# 700C 1/8” Hydronic Air Vent 53628 700QC 1/8” Hydronic Air Vent With Check 361597
For Water Management and Energy Conservation
Vent Rite Air Valves Non-Vacuum Vents
Bell & Gossett
Automatic Air Vents
No. 87 Automatic Air vents are designed to vent the accumulation of troublesome air wherever it can be trapped. The No. 87 has a combination of 1/2” FPT / 3/4” MPT connection. SYSTEM mfr# PART# DESCRIPTION Connection webb# 87 113021 Automatic Air Vent Combination 150718 3/4” NPTM 1/2” NPTF DT-2 113041 Drain-O-Tank 1/2” NPTM 470
Air Vents
417 Coin Vent Installed on water or steam radiators. The coin vent features special hydroscopic cellulose discs in the valve body. When dry the discs allow air to be released from the system. Once the air is purged the discs would then come in contact with system water, and would swell to create a positive shut-off. 400-3, 426, 418-3 Hy-Vents Taco Hy-Vents in 1/8”, 1/4” and 11/2” x 3/4” threaded connections, the high capacity float style vents can be placed either on the boiler or at the high point throughout the system. 409 Vent The Taco 409 air vent is a heavy duty cast iron vent rated to 300 psi system operating pressure. It features a stainless steel float and internal mechanisms, a 3/4” system connection and a 1/4” outlet tapping. mfr# description webb# 417-3 1/8” Coin Vent 24902 400-3 1/8” Hy-Vent 24903 426 1/4” Hy-Vent 80195 418-3 1/2” X 3/4” Hy-Vent 166978 409-1 3/4” Cast Iron Vent 85064
44 6_Hydronics-Steam_p83.indd 44-45
F.W. Webb Company
mfr# description webb# 1 Adjustable Angle Vent 496 11 Angle Vent 26209 31 1/8” Straight Vent 26211 33 1/4” Straight Vent 26212 35 3/4” M X 1/2” F Main Vent 26213 75 3/4” M X 1/2” F Main Vent 26216 77 3/4” M X 1/2” F Main Vent 26217
Use For
Mfr#
Free Standing Radiators
1 11
connectioN 1/8” Male
mfr# 2010100 2010400
size webb# 30784 1/2” 54174 3/8”
6
This is one of the best tools around for cutting gauge glass. It’s the only tool recommended for cutting Redline and High Pressure Glass. It cuts easily and cleanly and leaves clean straight edges.
#1
Vent Port
Oper. Press
O.A. HT.
3/32”
3 psi
31/4” Yes
1/16”
6 psi
23/4” —
Adj.
1/8” Male
1/16”
6 psi
33/4” —
33
1/4” Male
1/16”
6 psi
33/4” —
Main Vents
35
3/32”
3 psi
—
77
Complete Gauge Glass Sets
WP-1
31
75
mfr# size webb# Standard Clear 8GAGE 5/8” X 8” 69725 10GAGE 5/8” X 10” 69726 12GAGE 5/8” X 12” 55789 18GAGE 5/8” X 18” 69727 High Pressure 12RGAGE 5/8” X 12” 69728 18RGAGE 5/8” X 18” 68729 Gauge Glass Washers GGW58-100 Standard 16819 GGW3-12 High Pressure 244237 CONE-1819-00 Brass Washer 3964 CONC-140806 Glass Gauge Nut 3966
Gauge Glass Cutters
Convector & Risers
3/4” Male X 1/2” Female
mfr# description webb# GB2 2” GPM Flow Regulator 6830 GB212 21/2” GPM Flow Regulator 6831 GB3 3” GPM Flow Regulator 6832 GB312 31/2” GPM Flow Regulator 6833 GB4 4” GPM Flow Regulator 6834 GC5 5” GPM Flow Regulator 6835 GC6 6” GPM Flow Regulator 6836
Gauge Glass and Washers
3/32”
5 psi
—
1/8”
31/2 psi
—
WP-1
Dole Air Vents for One Pipe Systems mfr# description webb# 1A 1/8” Angle Adjustable Vent 6822 1933A 1/8” Angle Vent 6826 1933S 1/8” Straight Vent 6827 1933SS34 Straight Air Vent 45100
Dole Air Vents for Hot Water Systems mfr# description webb# 4 3/4 M X 1/2 F Air Vent 45096 9 1/8” Coin Vent 45097 10 Valve Key 45098 10-4 Valve Key 54194
www.fwwebb.com
Hydronics/steam
Quick, uniform distribution of heat to all radiation is the first essential to perfect performance. This requires balancing the radiation by controlled venting. Vent-Rite #1 Non-Vacuum vents are adjustable and all vents are designed for positive action and straightline venting. They function automatically to vent the air.
The Dole Flow Regulator is self-cleaning and designed to deliver a constant volume of water flow output over a wide pressure drop range. The regulators are designed for a maximum system pressure of 200 PSI. Multi-orifice flow inserts are used, where posible, in regulators with rates between 1 GPM and 4 GPM.
Gauge Glass
997
997
F.W. Webb with WebbConnect™ allows you to: . figure jobs WebbConnect® . get pricing . order material
Our #997 gauge glass cutter replaces the older tool whith the external chain. Because there is no more wrapping around of the chain, this tool is much easier and faster to use. It allows you to cut standard gauge glass up to 3/4” in diameter. mfr# description webb# WP-1 Gauge Glass Cutter 162182 997 Glass Squeeze & Snap Cutter 55790
24 hours a day / 7 days a week! The F.W. Webb Heating Catalog
F.W. Webb Company
45 3/23/08 8:55:31 PM
SECTION
SECTION
6
6
Relief Valves Hot Water Boiler Relief Valves
Safety Relief Valves
Automatic Reseating T & P Relief Valves for hot water supply tanks and heaters
Model# 40XL-5 40XL-8 40XL-4 40XL-7
Size (DN) M=MALE F=Female Inlet & Outlet
Thermostat Length
5”
3/4” M X 3/4” F
8”
1” M X 1” F
4” 7”
CSA Temp. Steam Rating BTU/hr.
ASME Pressure Steam rating BTU/ Hr @ 150 PSI set Pressure
200,000
1,437,600
500,000
2,134,000
Webb# 34982 28623 47070 47071
• These combined two-in-one Temperature and Pressure relief valves provide the least expensive and proven means for protection against both excessive temperature and pressure emergency conditions. • Fully automatic temperature and pressure relief protection for domestic hot water supply tanks and heaters based on the latest ANSI Z21.22 listing requirements for temperature discharge capacity. mfr# description webb# 100XL-4 3/4” X 4” Insert, 150 psi 28639 100XL-8 3/4” X 8” Insert, 150 psi 28640
• Connects to 3/4” temperature and pressure relief valve drain connections. • For use on T & P relief valves with up to 100,000 BTU/hr. rating. • Model 100DT for use with side mounted relief valves. Drop length is 48”.
46 6_Hydronics-Steam_p83.indd 46-47
F.W. Webb Company
125 PSI
150 PSI
Model#
Size
740
3/4” X 1
30 PSI
1,352,000
740
1” X 11/4”
1,300,000
1,899,000
740
11/4” X 11/2”
2,105,0000
3,075,000
174A
3/4”
650,000
1,695,000
2,070,000
2,445,000
740
11/2” X 2”
2,900,000
4,237,000
1”
1,005,000
2,635,000
3,215,000
3,795,000
740
2” X 21/2”
5,250,000
7,672,000
174A
11/4”
1,682,000
4,399,000
5,370,000
6,340,000
174A
11/2”
2,020,000
5,290,000
6,460,000
7,630,000
174A
2”
3,815,000
9,970,000
12,170,000
14,370,000
374A
3/4”
—
—
—
550,000
30 lb. Safety Relief Valves mfr# description webb# 1040705 3/4” X 3/4” M X F 30 lb. Relief Valve 56434 1040805 3/4” X 3/4” F X F 30 lb. Relief Valve 56435
Steam Boiler Safety Valves Series 315 and 415 ASME rated and tested steam safety relief valves
mfr# description webb# N36M1-12 1/2” 28641 N36M1-34 3/4” 28626
ASME Steam Discharge Capacity lbs/hr @ 15 psi webb#
315-M1 3/4” X 3/4” 415-M1 3/4” X 3/4”
375 450
Pressure Relief Valves Series 250
Series N36 Water service vacuum relief valves • Automatically vents a closed system if vacuum occurs. • Allows air to enter the system. • Relieves vacuum conditions which could siphon the water from the system and burn out a water heater or collapse a tank.
6
mfr# description webb# 3L-34 3/4”, 150 psi 28625 53L-150-12 1/2”, 150 psi 34983 53L-175-12 1/2”, 175 psi 73185
Vacuum Relief Valves
• For low pressure steam heating equipment. • Standard relief pressure 15 psi. mfr# size
Model 53L – same as Model 3L except 1/2” inlet/ outlet. Relief Valves for Hot Water Supply Systems design certified and listed by CSA. Does not comply with ASME requirements. Model 3L – ASME rated, design certified and listed by CSA. Size 3/4”, NPT male inlet x NPT female outlet. ASME construction and tested, listed and certified by the National Board of Boiler and Pressure Vessel Inspectors.
50 PSI
925,000
174A
Drain Lines Models 100DT Drain lines for T & P relief valves
(National Board Certified Ratings) BTU Steam Discharge Capacities (lbs./hr.)
Series 53L/3L Poppet type pressure relief valves for protection against excessive pressure
Hydronics/steam
Series 100XL Self-closing T & P safety relief valves for hot water storage tanks and heaters
100 PSI
mfr# description webb# 530C-12 1/2” Adjustable Relief 55815 530C-34 3/4” Adjustable Relief 85003
Safety Relief Valves Settings and Relieving Capacities
(National Board Certified Ratings) BTU Steam Discharge Capacities (lbs./hr.)
30 PSI
• Designed for use as protection against excessive pressure build-up in systems containing water, oil and air. • Adjustable pressure relief range 50-175 psi. • Maximum pressure 300 psi. • Maximum temperature 180°F.
mfr# description webb# 740-30-34 3/4”, 30 psi 54607 740-30-1 1”, 30 psi 54608 740-30-112 11/2”, 30 psi 54610 740M-30-114 11/4”, 30 psi 54609 740-30-2 2”, 30 psi 54611
Safety Relief Valves Settings and Relieving Capacities Size
Series 530C Calibrated pressure relief valves
• For hot water heating boiler pressure protection.
mfr# description webb# 174A-30-34 3/4”, 30 psi 28627 174A-40-34 3/4”, 40 psi 81202 174A-50-34 3/4”, 50 psi 78961 174A-100-34 3/4”, 100 psi 78962 174A-150-34 3/4”, 150 psi 78964 174A-30-1 1”, 30 psi 28628 174A-30-112 11/2”, 30 psi 28630 174A-30-2 2”, 30 psi 28631 174A-75-34 3/4”, 75 psi 78973 374A-30-34 3/4”, 30 psi 31452
Model#
Pressure Relief Valves
Series 740 Iron body ASME rated water pressure relief valves
• For hot water heating and supply boilers. • Pressure protection only. • Series 174A bronze body construction resists corrosive water conditions of water supplies. • Model 374A has iron body with bronze inlet; 550,000 BTU/hr. rating.
Water Heater T & P Safety Relief Valves
mfr# description webb# 100DT 3/4” X 48” 57843
Commercial Hot Water Boiler Relief Valves
Series 174A, Model 374A ASME water pressure safety relief valves
• The combined two-in-one Temperature and Pressure relief valve provides the least expensive and most proven means for protection against both excessive temperature and pressure. • Fully automatic temperature and pressure relief protection for hot water supply tanks and heaters based on the latest ANSI Z21.22 Listing Requirements for temperature discharge capacity.
Relief Valves
• For tanks and hydronic heating systems. • Protects against over-pressure. • Minimizes hammering with flash steam. • Low differential pressure – 3 psi between opening and closing. • Meets ASME Pressure Vessel & Boiler Code, Section IV. • Sizes and material – 3/4” - 1” NPT – bronze body & seat. – 2” NPT – cast iron body, brass seat. • EPDM rubber diaphragm and seat disc. • Maximum temperature 250°F. • Maximum operating pressure range . 30 – 125 psi. mfr# description webb# 250-34-30 3/4” Relief Valve 30247
— 72337
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
47 3/23/08 8:55:37 PM
SECTION
SECTION
6
6
Pressure Reducing Valves Bell & Gossett
Pressure Reducing Valves Reducing valves fill the system to a preset pressure for optimum performance. • Fast fill feature reduces start-up time and labor. • Low inlet pressure check valve help prevent loss of system pressure if the supply water drops below system pressure. • Convenient cleanable strainer is designed to prevent dirt and sediment from entering the system. • Brass body construction is highly resistant to corrosion – ideal for water systems. Combination “Dual Units”
Mfr# F-3
pART# 110197
COMPONENT vALVES
BODY MATERIAL
Relief, FB-38
Brass
Connection in inches BOILER
FILL
WEBB#
1/2 NPT
1/2 NPT
479
Mfr#
BODY pART# MATERIAL
B-38
110190
B7-12
110196
FB-38
110192
FB-38TU
110193
size inches
factory setting adjustable Connection (PSIG) range (PSIG)
1/2”
Brass
3/4” 1/2”
WEBB# 476
NPT
12
10-25
Union
475 477 54727
Relief & Reducing Valves
• Reliable electronic operation. • Time delay prevents burner short cycling. • Low maintenance – no blowdowns. mfr# description webb# 400 24V 58383 450 120V 58847 45-215 Standard 3/4” Probe 79506 1100 Mini 268513 1150 Mini 120V 310462
mfr# description webb# 24 Vac Auto Reset LNA0243S-1 3/4” NPT Short Probe 254727 LNA0243N-1 3/4” NPT Probe with Test Button 254721 LNA0242S-1 1/2” NPT Probe with Test Button 254723 120 Vac Auto Reset LNA1203S-1 3/4” NPT Short Probe 252237 LNA1203N-1 3/4” NPT Probe with Test Button 254722
Low Water Cutoffs Replacement Parts mfr# description webb# P2N-1 1/2” NPT Probe 254729 P3N-1 3/4” NPT Probe 254728
VXT Water Feeder
• Adjustable delay before feed. • Adjustable feed amount. • Can be used with any low water cut-off. • Two feed cycles. • Lock-out after second cycle.
Feed water pressure regulators and dual control for hot water boilers Series 1156F/1450F • Used on boiler feed lines to provide make up water to the system. • Series 1450F – combines features of 1156F and rugged iron body diaphragm relief valve. Set @ 30 psi.
6_Hydronics-Steam_p83.indd 48-49
mfr# description webb# 170SV 120V With Auto Reset 46825 550 120V With Manual Reset 58382
The Taco LWCO provides reliable protection for all types of boilers, from small residential hot water boilers to large industrial steam boilers. The LWCO can also activate alarm systems or automatic water feeders. A probe uses the boiler’s water to complete an electrical circuit. As long as water covers the probe, the electronic circuit. If the water level drops below the probe, the circuit is broken, shutting down the burner and protecting the boiler.
HYDROLEVEL
Pressure Reducing Valve
Low Water Cutoff
Complete float and dual switch assembly. Maximum steam pressure 15 psi. mfr# description webb# SAN89D Float & Dual Switch Assembly 80060
www.fwwebb.com
6
mfr# description webb# VXT24 24V 58385 VXT120 120V 79688
Model SAN89D Float and switch assemblies for servicing low water cut-offs
mfr# description webb# SB1156F Bronze 1/2” Union, Solder 28647 TB1156F Bronze 1/2” Union, Threaded 28646 B1156F 1/2” Bronze 204996 S1450F Dual Relief, 1/2” Union, Solder 28649 T1450F-12 Dual Relief, 1/2” Union, Threaded 28648 56CB102-1 1/2” Gasket f/1156-1450 91291 N256-34 Bronze 3/4”, Threaded 68148
F.W. Webb Company
• Reliable electronic operation. • Low maintenance. • No moving parts in boiler water. • Easy to install. • 100% factory tested.
Reducing Valve
48
HYDROLEVEL For Hot Water Boilers
Low Water Cutoffs
Hydronics/steam
mfr# description webb# 329-3 1/2” Fast Fill Reducing Valve 24897 329-T3 1/2” Threaded Fast Fill Reducing Valve 24898 334-T3 1/2” Fast Fill Dual Control 24899 335-3 1/2” Bronze Reducing Valve 24901 3350-1 1/2” Union Cartridge Style Pressure 222606 Reducing Valve
Pressure Reducing Valve
Low Water Cut-Offs
HYDROLEVEL For Steam Boilers
Pressure Reducing Valves FB-38
Low Water Cut-Offs & Feeders
The F.W. Webb Heating Catalog
F.W. Webb stocks Buderus heating products! F.W. Webb Company
49 3/23/08 8:55:48 PM
Low Water Cut-Offs & Feeders
SECTION
SECTION
6
6
Low Water Cut-Offs & Feeders
Low Water Cut-Offs — Electronic for Steam Boilers
Low Water Cut-Offs — Mechanical for Steam & Hot Water Boilers
Series PS-800
• For residential, commercial, and industrial applications. • Heavy duty. • Includes No. 2 switch. • Maximum boiler pressure 50 psi. • Use with TC-4 on hot water systems.
• For residential and commercial applications. • Electronic operation.
PS-800
New Features: • User friendly diagnostics. – Red low water and shorted probe LED. – Green power and test LED. • Higher probe sensitivity: 7,000 ohms. • No lock out with loss of power if probe is in water. • Delay on Make (DOM) feature (15 seconds). • Delay on Break (DOB) feature (10 seconds). • No blow down of control required when mounted directly into boiler tappings. • Test button standard on all models. • Options available include – Manual reset. – Extended barrel, remote and short probe models. – 120 volt and 24 volt models (24 volt models meet ANSI specification Z21.13a). • Power consumption 1.7 VA. • Provisions to add alarm or automatic water feeder. • Maximum ambient temperature 120°F. • Maximum steam pressure 15 psi. • Maximum water temperature 250°F.
Low Water Cut-Offs — Mechanical for Steam Boilers Series 67
Series 67
• For residential and (where codes allow) commercial applications. • Electro-Mechanical operation. • Automatic reset feature resumes operation after a power outage when water is on probe. • No blow down required. • 6,000 ohms probe sensitivity. • Maximum ambient temperature 120°F. • Maximum steam pressure 160 psi. • Maximum water temperature 250°F. mfr# Model# description webb# RB-120 144675 120V Low Water Cut-Off (Probe Type) With Test Light 12460 RB-122 120V Low Water Cut-Off 268720 RB-24 24V Low Water Cut-Off 167151
6_Hydronics-Steam_p83.indd 50-51
F.W. Webb Company
6
Series 69 Built-in Low Water Cut-Offs
RB-120
50
• For residential and commercial applications. • For boilers of any steaming capacity. • Quick hook-up fittings provided. • Lever-operated, full port ball valve for easy blow down. • Adjustable BX outlet for easy installation. • Dual precision switches for dependable operation of the low water cut-off and alarm or electric water feeder. • Optional features: – Low voltage switches for self-generating millivolt circuits. – Manual reset switch. • Large float chamber. • Maximum steam pressure 20 psi. mfr# Model# description webb# 67 149400 Low Water Cut-Off 12438 67-G 149600 Low Water Cut-Off f/Millivolt Service 12439
Low Water Cut-Offs — Electronic for Hot Water Boilers
RB-120
mfr# Model# description webb# 63-M 143100 63 With Manual Reset 12453
Hydronics/steam
mfr# Model# description webb# PS-800 Series — Water PS-801-120 153875 120V Low Water Cut-Off (Probe Type) 69796 PS-802-24 153917 24V Low Water Cut-Off (Probe Type) 67716 PS-850 Series — Steam PS-851-120 153895 120V Low Water Cut-Off (Probe Type) 12457 PS-851-M-120 153986 120V Low Water Cut-Off (Probe Type) With Manual Reset 12462 PS-852-M-24 153918 24V Low Water Cut-Off (Probe Type) With Manual Reset 12461
63-M
www.fwwebb.com
Series 69
• For residential and commercial low pressure steam boiler applications. • For boilers of any steaming capacity. • For mounting in 21/2” NPT boiler side tappings. • Insertion lengths available in 13/16 – 41/8”. • Packless bellows. • Adjustable BX outlet for easy installation. • Dual precision switches for dependable operation of the low water cut-off and an alarm or electric water feeder. • Optional low voltage switches for self-generating millivolt circuits. • Maximum steam presssure 20 psi. mfr# Model# description webb# 69 153900 Low Water Cut-Off With 41/8” Insertion Length 12441 169 155100 69 Low Water Cut-Off With 31/8” Insertion Length 69795 369 155300 69 Low Water Cut-Off With 13/4” Insertion Length 12444
The F.W. Webb Heating Catalog
F.W. Webb Company
51 3/23/08 8:55:49 PM
Low Water Cut-Offs & Feeders
SECTION
SECTION
6
6
Low Water Cut-Offs & Feeders
Low Water Cut-Offs — Mechanical for Steam Boilers
Water Feeders — Electric
Series 101-A
Series 150S Low Water Cut-Off/Pump Controllers
Series 150S
• For commercial and industrial low or high pressure boiler applications. • For boilers of any steaming capacity. • Monel bellows provides corrosion resistance. • Snap action switches for high temperature service. – 1 Single pole, single throw switch for pump control. – 1 Single pole, double throw switch for low water cut-off and alarm actuation. • Optional features: – Manual reset. – 2 Single pole, single throw switches. – 2 Single pole, double throw switches. – Float block. – BSPT threads. • Maximum pressure 150 psi.
Series 101-A
Water Feeders — Mechanical
Water Feeders — Electric
Series 47-2 Mechanical Water Feeders/Low Water Cut-Offs
Series WF Uni-Match®
Series 47-2
F.W. Webb is the largest distributor of weil-Mclain Boilers!
6_Hydronics-Steam_p83.indd 52-53
F.W. Webb Company
www.fwwebb.com
• For steam and hot water boilers with cold water feed. • Continuous maintenance of minimum safe water level, independent of electrical service. • Proportional feed action. • Quick hook-up fittings provided. • Quick-change replaceable cartridge valve and strainer. • Optional features – No. 2 switch. – Manual reset. • Model 47 can be field upgraded with a No. 2 switch to add low water cut-off function. • Maximum water supply pressure 150 psi. • Maximum boiler pressure 25 psi. • Maximum inlet water temperature 120°F. mfr# Model# description webb# 47-2 132800 Low Water Cut-Off/Feeder With No.2 Switch 12431
6 Hydronics/steam
• For low pressure steam boilers with cold water feed. • Three position slide allows the timing cycle to be matched to that of the major low water cut-off manufacturers. • Field adaptable feed rate – 1, 2, or 4 gpm. • Electronic operation provides consistent, accurate cycle-to-cycle repeatability. • Universal design simplifies selection and reduces stock. • Can be used with mechanical or electronic low water cut-off controls. • Manual feed button. • Includes 3/8 NPT thread x 1/2” tubing adapters for quick installation with 1/2” copper tubing • Easy to clean strainer. • Maximum water pressure 150 psi. • Maximum boiler pressure 15 psi. • Maximum water temperature 120°F. • Maximum ambient temperature 100°F. • Maximum power consumption (during water feed only). – 15 VA at 24 Vac. – 20 VA at 120 Vac.
Series 51-2 Mechanical Water Feeders/Low Water Cut-Offs
mfr# Model# description webb# WF-2-U-120 169560 120 Volt Electric Water Feeder 69797 WF-2-U-24 169550 12 Volt Electric Water Feeder 47073
52
• For low pressure steam boilers with cold water feed. • Eliminates necessity to manually add water to the boiler. • Can be used with mechanical or electronic low water cut-off controls. • Quick-change replaceable cartridge valve and strainer. • Manual feed button. • Model 101-A features a 120 Vac solenoid. • Model 101-A-24 features a 24 Vac solenoid and a separate 50VA transformer. • Maximum water supply pressure 150 psi. • Maximum boiler pressure 25 psi. • Maximum inlet water temperature 120°F. • Maximum power consumption. – 40 VA at 24 Vac. – 40 VA at 120 Vac. mfr# Model# description webb# 101A 169400 120 Volt Electric Feeder 12435 101A-24V 169500 24 Volt Electric Feeder 12436
mfr# Model# description webb# 172702 150SM Steam Low Water Cut Off 12463
Series WF
(cont.)
Series 51-2
• For low pressure steam and hot water boilers larger than 5,000 sq. ft. capacity with cold water feed. • Quick change replaceable cartridge valve and strainer. • Optional features – No. 2 switch. – Manual reset. – Float block. • Proportional feed action. • Model 51 can be field upgraded with a No. 2 switch to add low water cut-off function. • Maximum water supply pressure 150 psi. • Maximum inlet water temperature 120°F. • Maximum vessel pressure 35 psi. mfr# Model# description webb# 51-2 135000 Low Water Cut-Off/Feeder With No.2 Switch 12433
The F.W. Webb Heating Catalog
F.W. Webb Company
53 3/23/08 8:55:51 PM
Low Water Cut-Offs & Feeders
SECTION
SECTION
6
6
Water Feeders — Make-Up
Replacement Parts
Series 21
For Series 67 Low Water Cut-Offs
• For boiler receiver tanks. • Direct mounting eliminates need for equalizing connections. • Proportional feed action. • Mounting Flange – six 7/8” bolt holes on a 53/4” bolt circle. • Soft seat provides positive seal. • Maximum water supply pressure 150 psi. • Maximum inlet water temperature 120°F. • Maximum vessel pressure 35 psi.
Series 21
Low Water Cut-Offs & Feeders
Model 6667
mfr# Model# description webb# 6667 153825 Head Mechanism 12484 67-12 318800 Gasket 55578 11-MV 3009200 Replacement Switch For Millivolt Service 12486 11 3009100 Replacement Switch 12485 SA67-2 344200 Float & Bellows Assembly 12498 14-B 310447 Bown-down Valve 12487 37-39 313200 Bown-down Valve Gasket 12489
Series 67 Components
mfr# Model# description webb# 21 126400 Make-Up Water Feeder 12437
Blow Down Valve Series 14-B
Series 14-B
• For McDonnell & Miller control blow down valve replacement. • Full-ported ball action valve. • Teflon® seats provide bind free, leak tight ball movement. • Easy open handle keeps hands away from hot water and steam. • Gasket and mounting screws included. • Maximum pressure 30 psi.
6 Hydronics/steam
mfr# Model# description webb# 14B 310447 Blow Down Valve 12487
Blow Down Valve mfr# description webb# H23W Dirt pocket cap for McDonnell & Miller (3/4”-NPT) with gasket and (4) bolts 259932 H23-1W Blow Down Kit for McDonnel & Miller (dirt pocket cap, 69869 full flow ball valve, nipple, gasket, (4) bolts
For Series 150 Low Water Cut-Offs mfr# Model# description webb# 150-HD 173000 Head Mechanism With Mercury Switch 12483 150-14H 325500 Head Gasket (for raised face head flange, 8 holes) 79944
For Series 851 Make-Up Water Feeders 150-HD
F.W. Webb with WebbConnect™ allows you to: . figure jobs ® WebbConnect . get pricing . order material 24 hours a day / 7 days a week!
54 6_Hydronics-Steam_p83.indd 54-55
F.W. Webb Company
www.fwwebb.com
150-14H
mfr# Model# description webb# 347100 SA101-38 Strainer Basket (includes Tetraseal O-Ring & bolts) 12499
For Series 51/51-2 Water Feeder/Low Water Cut-Offs mfr# Model# description webb# 51-2-HD 135100 Head Mechanism With No. 2 Switch 85014 SA51-101-102 342500 Valve & Strainer Kit 12497 F-26 304100 Gasket 55581 37-27 312800 Gasket 55582 51-2-HD
For Series 63 Low Water Cut-Offs mfr# Model# description webb# CO-12 302600 Head Gasket 12490
The F.W. Webb Heating Catalog
F.W. Webb Company
55 3/23/08 8:56:10 PM
Low Water Cut-Offs & Feeders
SECTION
SECTION
6
6
Flow Switches Test-N-Check Valves
Replacement Parts
(cont.) For Series FS4-3 General Purpose Liquid Flow Switches
Series TC-4
mfr# Model# description webb# FS4-15SS 310451 Stainless Steel Paddle Kit 108733
For Series 47/47-2 Mechanical Water Feeder/Low Water Cut-Offs
Paddle Kit
mfr# Model# description webb# SA47-0101-102 341600 Valve, Cartridge & Strainer Assembly Kit 12494 37-26 312800 Gasket 12488 2 110000 Switch 30246 2-M 110100 Switch With Manual Reset 69798
Series TC-4
• For hot water boilers. • Simplifies ASME CSD-1a. code mandated testing of low water cut-offs by eliminating the need to drain the system. • Includes one upper and one lower valve for mounting at crosses in equalizing lines. • Restricts water flow when the low water cut-off ’s blow down valve is open. • Adjustable built-in vacuum breaker in upper valve provides rapid evacuation of water from the float chamber. • 1” NPT. • Maximum temperature 250° F. • Maximum pressure 160 psi. mfr# Model# description webb# TC-4 195000 Test-N-Check Valves, Set of 2 55575
Series 47/47-2 Components
Flow Switches — Liquid Series FS4-3 General Purpose Liquid Flow Switches
Series FS4-3
• Universal design serves the widest variety of applications. • For starting or stopping electrically operated equipment such as signal lights, alarms, motors, automatic burners, metering devices and others. • Replacement for common flow switches from Johnson/Penn, Potter/Taco, Watts, Hydrolevel and other manufacturers. • 1” NPT. • Two electrical knock-outs allows connection from either end. • Sensitivity adjusting screw makes flow adjustment easy. • Single pole, double throw snap switch. • Hardened stainless steel bearings minimize friction. • Sealed Monel bellows. • Four stainless steel paddles included – 1”, 2”, 3”, & 6”. • Optional features – Time delay. – Two SPDT switches to make or bread two separate circuits. – Reinforced paddles. – Materials on construction suitable for corrosive liquids. – Fire sprinkler service – Model F34-3F only. – BSPT threads. • Minimum temperature (fluid or ambient). • Maximum temperature 300°F. • Maximum pressure 160 psi.
6 Hydronics/steam
mfr# Model# description webb# FS4-3 114400 General Purpose Flow Switch 12477
F.W. Webb stocks Peerless boilers!
56 6_Hydronics-Steam_p83.indd 56-57
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
57 3/23/08 8:56:38 PM
Flow Switches
SECTION
SECTION
6
6
Flow Switches — Liquid
(cont.) Series FS8-W General Purpose Liquid Flow Switches
FS8-W
Circulators & Accessories Bell & Gossett
• For general purpose applications with environmental exposure, or those requiring a water-tight, dust tight, or a NEMA.4X rates flow switch. • 1” NPT. • Sealed Monel Bellows. • Single pole, double throw snap switch. • For stainless steel paddles included – 1”, 2”, 3”, and 6”. • Sensitivity adjusting screw makes flow adjustment easy. • Optional features –BSPT threads. – Gold plated contacts. • Minimum temperature (fluid or ambient) 32°F. • Maximum temperature 225°F. • Maximum operating pressure 160 psi. • Replacement for NEMA 4X-style flow switches from Potter/Taco, Watts, Penn and other manufacturers. mfr# Model# description webb# FS8-W 120601 General Purpose Flow Switch With NEMA 4X Enclosure 111265
Low Water CutOffs & Feeders
Three-Piece
Mfr# Series 100
100 NFI
Series HV
HV NFI
102210
1
2 NFI
102214
2
2”
Series 100
3/4
100 BNFI
106197
1 & 11/4
485
1/12
115 - with built-in overload protection 1/6
30074 486 85470
Compact Design/Series LR Motor characteristics@60 Hi
Mfr#
FLANGE SIZE INCHES Part # Construction (NPT)
HP
VOLtage
WEBB#
LR-20BF
106506
1/20
115 - with built-in overload protection
34524
Cast Iron
3/4, 1, 11/4, 11/2
Series LR
Maintenance-Free Circulators
NRF
Mfr#
pART#
flange size inches (NPT)
WEBB#
NRF-22
103251
3/4, 1, 11/4, 11/2
119280
www.fwwebb.com
6
Replacement Parts Parts for Series 100 Booster Pumps description
100 N FI
100 BI
100 AB
Bronze Bearing Assembly Bearing Assembly With NFI Impeller
189134
Plastic Impeller
189132
Bronze Impeller
100 BHR
WEBB#
189034
72154 53646
189132 118431
118431
53645 55265
Coupler Assembly
118705
118705
118705
118705
28553
Flange Gasket Set - Ring Type
118368
118368
118368
118368
46366
F.W. Webb Stocks Buderus, burnham, peerless, smith and weil-mclaiN Commerical Boilers.
F.W. Webb is the exclusive distributor of the Energy Star rated TRIO cast iron boiler
6_Hydronics-Steam_p83.indd 58-59
106189
Hydronics/steam
• For general purpose applications where high sensitivity is required and moderate or low flow rates are encountered such as air conditioning, heating and hydronic systems, water, fuel oil, some viscous liquids and oils in process work. • In-line configuration eliminates need for a pipe tee. • High flow capacity. • 1/2” NPT. • Single pole, double throw snap switch. • Switch compartment is completely sealed to protect it from the liquid. • Sensitivity adjusting screw makes flow adjustment easy. • Optional features – BSPT threads. – Gold plated contacts. • Minimum temperature (fluid or ambient) 32°F. • Maximum temperature 225°F. • Maximum operating pressure 100 psi.
F.W. Webb Company
BRONZE
Cast Iron Wet/Rotor/NRF
mfr# Model# description webb# FS1 113200 High Sensitivity Flow Switch – 1/2” NPT Body 12476
58
Flange Motor characteristics@60 Hz Size Inches model # Part # model # Part # (NPT) HP VOLtage WEBB# CAST IRON
Series FS1 High Sensitivity Liquid Flow Switches
Series FS1
Oil Lubricated Circulators
The F.W. Webb Heating Catalog
F.W. Webb Company
59 3/23/08 8:56:51 PM
Circulators & Accessories Bell & Gossett
Replacement Parts
SECTION
SECTION
6
6
Circulators & Accessories “00” Series Cartridge Circulators
(cont.)
• Unique replaceable cartridge design– field serviceable. • Unmatched reliability–Maintenance free. • Quiet, efficient operation. • Standard high capacity output–compact design.
Parts for Booster Pumps description
HV NFI
HV BI
HV AB
HV BNFI
WEBB#
2” Bearing Assembly
189165
189165
189165
189165
53643
2” Impeller
189128
189128
53644
Coupler Assembly
118705
118705
118705
118705
28553
118373
118373
118373
118373
53636
Flange Gasket Set
description
1” PR
21/2”
LD-3”
HD-3”
WEBB#
Bearing Assembly (C.I. or Bronze)
189105
189105
189105
189105
55267
Coupler Assembly
189110
Mfr#
118723
118723
118723
31298
007
Larger Residential Zones
24866
Radiant Heating Zones
58701
69659
3/4”, 1”, 11/4” & 11/2” Flanged
Body Gasket, 100 Series P04080 P04080 P04080
72154
67559
Light Commercial Zones
47074
0011
High Flow - Radiant
69932
11/4” & 11/2” Flanged Replaces HV
194 - 1542F
11/4” & 2” Flanged Replaces 2”
194 - 2124F
3/4”, 1”, 11/4” & 11/2” Flanged
Not Included
Oil Wick Set
118395 118395 118395 118395 118395 118395 118395
Low Water Cut53645 Offs & Feeders 55265
Seal Kit (Booster Pumps)
118681 118681 118681 118681 118681 118681 118681
53642
P04890 P04890 P04890
53646
Body Gasket, PD35-37
P54710 P54710
Seal Kit, PD 60 Series
0013
“00” Series
186499 186499
Not Included
High Lead Loss - Radiant
0012-1 IB, AB IB, AB IB AB WEBB# 189105 186863 185260 185262
companion flanges
0010 0012
118844 189034 189134 189165 189136 189140
Body Gasket, HV Series
WEBB#
Residential Zones
009
Bearing Assemblies description
application
005 008
53642
Coupler Assembly
connection size
• Direct drive–low power consumption. • Universal flange to flange dimension. • Manufactured in a variety of sizes to match system requirements. • Residential and light commercial applications.
High Velocity
92024 216599
High Head - Geothermal
223094
application
WEBB#
Residential Zones & Radiant
370056
Larger Residential Zones
370057
application
WEBB#
Larger Residential Zones
254379
3-Speed with Integral Flow Check (IFC) Mfr#
connection size companion flanges
00RMS-F-IFC
3/4”, 1”, 11/4” & 11/2”
Not Included
Flanged
0010MS-F-IFC
Cast Iron with Integral Flow Check (IFC)
46366
Mfr#
connection size
companion flanges
007-F5-IFC 008-F6-IFC
Mfr #
Pump Shaft Size
Pump Series
HP
Frame Size
Motor shaft size
WEBB#
00R-F-IFC
118473
1/2”
PD-35 & PD-37
1/2 - 3/4
B&G
1/2”
259934
0010-F-IFC
3/4”, 1”, 11/4” & 11/2”
Not Included
Flanged
Radiant Heating Zones
Larger Residential Zones
0011-F-IFC
256090 282665 309249 309248
Bronze
Bell & Gossett
B&G Replacement Circulator Couplings For B&G
Mfr#
connection size
companion flanges
application
WEBB#
006-BC
1/2” Sweat
—
Recirc
24874
006-B
3/4” Sweat
—
Recirc
24873
3/4” FNPT Threaded
—
Recirc/Boosters
74756
Larger Residential Zones
24875
Radiant Heating Zones
67560
High Head Loss - Radiant
54563
006-BT4
mfr# description webb# Couplings H24-40W 1/12 – 1/6 HP Spiral 118705 69681 H24-10W 1/12 – 1/6 HP Zinc Spring 118705 28553 H24-60W 1/4 – 1/3 HP Cast Iron Spring 118723 69659 H24-15W 1/12 – 1/6 HP Cast Iron 118705 259933 H24-62W 1/2 – 3/4 HP 118473 259934 186410 1 HP Cast Iron 53639
007-BF5 008-BF6
3/4”, 1”, 11/4” & 11/2”
Flanged
009-BF5
Not Included
0010-B 0011-BF
11/2” Flanged
Hydronics/steam
Coupler Selection
6
67561 High Head
0012-B
201889 242596
Priority Zoning Circulators — Cast Iron Modular PC Board Design with Built-in Transformer & Relay Mfr # 007-ZF5-5
connection sizes
companion flange
application
WEBB#
3/4”, 1”, 11/4” & 11/2” Flanged
B&G
Larger Residential Zones
87921
“00” Taco Timer “00” Timer
60 6_Hydronics-Steam_p83.indd 60-61
F.W. Webb Company
www.fwwebb.com
Mfr # 265-1
The F.W. Webb Heating Catalog
Description
WEBB#
Analog Timer With Dust Cover
178946
F.W. Webb Company
61 3/23/08 8:57:11 PM
Circulators & Accessories
SECTION
SECTION
6
6
Replacement Parts
Circulators
Water Circulation – “00” and 100 Series
110, 111, 112, 113, 120 Red Baron Circulators Designed to efficiently circulate heated or chilled water in residential or light commercial Hydronic Systems. These circulators may also be used for zoning large installations and are available in bronze construction for domestic hot water applications.
Cast Iron Circulators Mfr#
110 Red Baron
connection companion size ranges WEBB#
110
24867
111 112
3/4”, 1”, 11/4” & 11/2” Flanged
Not Included
2” Flanged
Included
113
mfr# description webb# 005-019RP Cartridge Assembly f/005, 006, CI 79720 005-020RP Cartridge Assembly f/005, 006, Bronze 77195 007-042RP Cartridge Assembly f/007, CI 30334 007-045RP Cartridge Assembly f/007, Bronze 75479 008-044RP Cartridge Assembly f/007, 008, CI 79716 0010-021RP Cartridge Assembly 0010 CI 241912 0011-009RP Cartridge Assembly 009 CI 213967
24869
Low Water CutOffs & Feeders
24870
120
24871
Bronze Circulators Mfr#
connection companion size ranges WEBB#
111B
24876 3/4”, 1”, 11/4” & 11/2” Flanged
Not Included
112B
Description
WEBB#
110-251BF
3/4”
110-252BF
1”
110-253BF
11/4”
110-254BF
11/2”
24887
251
3/4”
30335
252
1”
253
11/4”
254
11/2”
24884 Bronze Threaded Freedom Flange Set
Ductile Iron Freedom Flange Set
24885 24886
30336
WEBB#
194-1543F
11/2”
Ductile Iron f/0012 Circulator
110880
194-2124
2”
Ductile Iron f/0012-F2 Circulator
188276
6_Hydronics-Steam_p83.indd 62-63
WEBB# 244091 247630 249998 254109 249999 264308 264298 264299
mfr# description webb# Bolt Kits - PurePro BP-392 Circulator Bolt Kit 165153 Flange Gaskets T36 Taco/B&G/Grundfos 190128 Red Rubber Flange Gasket T36-BR Taco/B&G/Grundfos 224560 Black Rubber Flange Gasket
6
purepro boiler trim packages are the only packages that give you the leading brand products in a single easy-to-carry box.
Circulator Couplings
Description
F.W. Webb Company
description 3/4” IPS PurePro Shut Off Flange 3/4” Sweat PurePro Shut Off Flange 1” IPS PurePro Shut Off Flange 1” Sweat PurePro Shut Off Flange 11/4” IPS PurePro Shut Off Flange 11/4” Sweat PurePro Shut Off Flange 11/2” IPS PurePro Shut Off Flange 11/2” Sweat PurePro Shut Off Flange
Replacement Parts
30338
Flange size
62
Mfr # 67778 67784 67779 67785 67780 67786 67781 67787
30337
2” 0012 Threaded Freedom Flange Sets Mfr#
Designed to isolate all 2 bolt flanged circulator pumps. Available in 3/4”, 1”, 11/4” and 11/2” Sweat and IPS connections. Features: • Full port forged brass ball valve. • Brass body and flange. • Solid chrome-plated brass balls with Teflon® seats. • Blowout proof stem sealed with Teflon®. • Vinyl coated handle. • Additional “T” handle included. • Includes mounting nuts and bolts. • Rated at 600 psi WOG.
mfr# description webb# 1600-160RP Cartridge Assembly f/1600 Series 54556 1600-169RP Flange Gasket f/1600 Series 79715 1600-846CRP Water Seal Kit f/1600 Series 54557
24878
Flange size
mfr# description webb# 59896167 UP1542FR Circulator 10961 59896268 UP1542FC Circulator 244415 59896341 UP515-58FC 3SP 250404 59896343FRC UP515-58FRC 3SP 255945 Flange Sets 519601 3/4” 10962 519602 1” 10963 519603 11/4” 10964 519605 11/2” 10965
Flanged Ball Valve
1600 Series Replacement Parts
24877
Freedom Flange Sets 005, 0070011, 0013, 0014 & 110-113 Mfr#
Features: • Built-in motor protection for long life. • Stainless steel construction for corrosion resistance. • Multiple fittings for a variety of applications. • 4-pole motor for low energy consumption. • Whisper-quiet operation for sound sensitive installations. • The New Brute II (UP 15-42) has 50% more starting torque for dependable starts in the worst conditions.
Hydronics/steam
110B
mfr# description webb# 007-003RP Circulator Gasket/O-Ring f/007 80202 0012-006RP Circulator Gasket/O-Ring f/0012 241913 110-009RP Circulator Coupling 54553 110-275RP Pump Seal 54555 110-361RP CI 110 Bearing Assembly 24931 111-058RP CI 111 Bearing Assembly 69778 112-120RP CI 112 Bearing Assembly 54548 120-067RP CI 120 Bearing Assembly 55775 110-362BRP Bronze 110 Bearing Assembly 54550 256-003RP Shutoff Flange Gasket Set 180071 110-023RP Circulator Gasket/Full Face 46365 006-047RP O Ring Replacement 254931 007-007RP Circ GSKT 2PK 58302
“00” Replacement Cartridges
24868
Circulators & Accessories
mfr# description webb# 110-009RP 110 Coupler 54553 TP425 110 Coupler 69669
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
63 3/23/08 8:57:52 PM
Valves
SECTION
SECTION
6
6
Valves
Thermostatic Radiator Actuators
Danfoss
T5086
RA 2000 Thermostatic Radiator Valve
Control room temperature by modulating the flow of hot water or steam through free-standing radiators, convectors or baseboard units. • T5086 nonelectrical thermostatic actuator mounts directly on V5086 valve body and modulates hot water or steam flow through valve in response to room temperature changes. • No electric power required.
New Danfoss RA 2000 thermostatic radiator valves utilize the latest vapor-filled bellows system. Based on a modulating proportional principle, a drop in ambient temperature causes the valve to open. This increases the supply of hot water or low-pressure steam entering the radiator. Conversely, a rise in ambient temperature causes the valve to close. This decreases the supply of hot water or low-pressure steam entering the radiator. Technical Data Limitations
Application Temperature mfr# TYPE Range Includes webb# T5086A1009 Hot Water, Steam 43º F To 79º F Integral Sensor, 108024 Integral Setpoint Hot Water, Steam 43º F To 79º F Remote Sensor, Remote 96700 T5086B1007 Setpoint, 6’6” Capillary 43º F To 79º F Remote Sensor, Remote 98010 T5086C1005 Hot Water, Steam Setpoint, 6’6” Capillary
T5086A
TYPE
Maximum temperature (ºF)
Maximum Diff. pressure (water)
maximum static pressure
maximum steam pressure
Maximum test pressure
RA2000
250
20 PSI (46 ft.)
145 psi (335 ft.)
15 psig
232 psi (536 ft.)
RA Operators
T5086B-C
013G8220
(Bodies Nickel Plated Bronze)
013G8200
Built-in
Valve-mounted Sensor and Dial
79121
013G8220
Built-in
Tamper-resistant Valvemounted Sensor and Dial
201603
013G8202
Remote
Valve-mounted Dial and Remote Sensor
6”
Heat-Gard™
mfr# 5321-1 5322-1 5323 5331-C1 5332 5333-2 5431-1
Description, Size & Type Connections webb# 68956 1/2” Angle NPT Union Connection 68964 1/2” Straight NPT Connection 68960 3/4” Straight Sweat Connection 54562 3/4” Angle NPT Connection 68965 3/4” Angle NPT Union Connection 68961 3/4” Straight NPT Union Connection 68957 1/2” Straight NPT Union Connection
Heat-Gard™ Thermostatic Operators mfr# 5201-2 5203-2 5206-2
Description webb# Direct Mount (Liquid) 68972 Remote Sensor 6’ Capillary 54565 Wall Mount 6’ Capillary 68975
F.w. webb stocks purepro energy saving products. 64 6_Hydronics-Steam_p83.indd 64-65
F.W. Webb Company
www.fwwebb.com
013G8562
013G8565
Max. sensor temp. (ºF)
Design
45-86
Webb #
201231 140
013G8562
Wall Mount
Combined Remote-mounted Sensor and Dial
6”
201626
013G8565
Wall Mount
Combined Remote-mounted Sensor and Dial
16’
79122
013G8564
RA2066 2 X 6 Cap. Tubes
Operator with Separate Remote-mounted Sensor
3’ + 3’
013G8564
50-90
212918
RA 2000 Valves Mfr #
valve size
pattern
connections inlet x Outlet
connections inlet x outlet
Webb #
013G8015
1/2”
1.6
013G8020
3/4”
2.7
013G8025
1”
013G8032
11/4”
2.8
224035
013G8014
1/2”
1.6
79123
013G8019
3/4”
013G8024
1”
013G8031
11/4”
2.8
203286
013G8013
1/2”
1.6
213827
013G8018
3/4”
2.7
013G8023
1”
013G8030
11/4”
013G8044
1/2”
013G0140
1/2”
Straight
Angle
Side Mount Angle
167179 FPT X MPT
2.8
2.7
FPT X MPT
2.8
163179 152732
201232 201627
79124
FPT X MPT
2.8
79120
2.8 Straight
2.7
6 Hydronics/steam
The Taco Heat-Gard™ Thermostatic valves keep a heating system comfort balanced by eliminating cold spots and overheating. Its proven design and reliable operation make it the simplest way to prevent energy waste and reduce heating costs. The Heat-Gard valve is made so that the complete cartridge can be replaced under pressure without draining the system, delivering a higher level of uninterrupted comfort control.
temp. range (ºF)
Description
013G8200
Heat-Gard™ Thermostatic Valves
capillary length
Mfr #
79118 Double Solder Union
1-PS with Vacuum Braker
79119 241897
RA to RA 2000 Adapter Mfr # 013G8070
The F.W. Webb Heating Catalog
Description
Design
WEBB#
RA to RA2000 Adapter
Allows RA2000 Operators to fit RA Valves
178946
F.W. Webb Company
65 3/23/08 8:58:13 PM
SECTION
SECTION
6
6
Valves Tempering/Mixing Valves Hot water extender tempering valves Series N170
For commercial applications, mixes cold and hot water to extend capacity of water heater, storage tanks and hot water boiler tankless heaters. Features: • All bronze construction. • Interchangeable thermostat. • High capacity. mfr# description webb# N170M2-34 3/4” 68775 N170M2-1 1” 68776 N170M2-114 11/4” 68777 N170M2-112 11/2” 68778
Purge & Balance Ball Valve Residential purge and balancing valve Series RPV • Provides a unique and low cost solution for start-up purging and balancing of hydronic heating loops. • Accurate balancing and drip tight shutoff. • Rugged, dual-ball valve design. • High-volume purging. mfr# description webb# RPVS-34 3/4” 28650 7866801 3/4” 58728
Series 70A
mfr# description webb# 70AF-12 1/2” 28642 70A-34 3/4” 28632 L70A-34 3/4” 81201 869100 Repair Kit f/70A 34164
Flow Control Valve Model P3 Multi-orifice flow control for tankless heaters • Designed to limit the flow of water to equipment. • Used for tankless heater installations.
5000 Series Mixing Valve The 5000 Series Mixing Valve is a dual purpose mixing or diverting valve. It is ASSE 1017 approved, providing shut-off reliability on either a hot or cold water supply failure. The high flow and low headloss characteristics make the 5000 Series ideal for domestic water, radiant applications, installations with large variations in flow rate and supply conditions, and installations requiring tightly controlled water temperature. The valves unique design and advanced thermostatic element ensures a stable mixed water temperature throughout the extended 85° – 150°F range. The 5000 Series provides fail-safe security and the ultimate performance in a mixing valve. mfr# description webb# 5002 1/2” Sweat Union Connections 188569 5003 3/4” Sweat Union Connections 161218 5004 1” Sweat Union Connections 76566
Replacement Parts for Mixing Valves mfr# description webb# 507-046RP 508/526 Mixing Valve Element 24932 5002-002RP Set of 3 Gaskets for Mixing Valve 247482
mfr# description webb# P3S-12 1/2” 28633
66 6_Hydronics-Steam_p83.indd 66-67
F.W. Webb Company
www.fwwebb.com
Gate, Check & Stop/Waste Valves mfr# description webb# Gate Valves T300-12 1/2” IPS 26181 T300-34 3/4” IPS 26182 T300-1 1” IPS 26183 T300-114 11/4” IPS 26184 T300-112 11/2” IPS 26185 T300-2 2” IPS 26186 T300-212 21/2” IPS 26193 T300-3 3” IPS 26194 T300-4 4” IPS 26195 T300S-12 1/2” COP 26187 T300S-34 3/4” COP 26188 T300S-1 1” COP 26189 T300S-114 11/4” COP 26190 T300S-112 11/2” COP 26191 T300S-2 2” COP 26192 Check Valves M31-12 1/2” IPS 26202 M31-34 3/4” IPS 26203 M31-1 1” IPS 26204 M31-114 11/4” IPS 26205 M31-112 11/2” IPS 26206 M31-2 2” IPS 26207 M31S-12 1/2” COP 26196 M31S-34 3/4” COP 26197 M31S-1 1” COP 26198 M31S-114 11/4” COP 26199 M31S-112 11/2” COP 26200 M31S-2 2” COP 26201
Stop & Waste Valves SW-12 1/2” COP 12COP 1/2” COP 12IPS 1/2” IPS 34COP 3/4” COP 34IPS 3/4” IPS
19714 39759 34564 19715 19713
Boiler Drain DO-12 12DO 34DO
39760 19716 19713
1/2” 1/2” 3/4”
Ball Valves General purpose ball valves are threaded-end and solderend valves feature bubble tight shut-off. Threaded mfr# Size webb# T103-12 1/2” 73303 T104-34 3/4” 73304 T105-1 1” 74526 T106-114 11/4” 165712 T107-112 11/2” 165713 T108-2 2” 165714
Sweat mfr# Size webb# C203-12 1/2” 73305 C204-34 3/4” 73306 C205-1 1” 74520 C206-114 11/4” 165717 C207-112 11/2” 165718 C208-2 2” 165719
The F.W. Webb Heating Catalog
Forged Brass Ball Valves Full Port Ball Valves Mfr# description webb# Regular Pattern, 150 WSP/600,400 WOG 101-043 1/2” S-1001 C X C 210974
Specialty Ball Valves Ball Valves with Compression Ends Mfr# description webb# Conventional Port with Waste 101-553 1/2” T-802 87116 101-554 3/4” T-802 87117 101-555 1” T-802 87118 Female X Sweat Ball Valves -Full Port Mfr# description webb# For Connecting Boilers to Copper Tube 101-623 1/2” T-1007 IPS X SWT 111123 101-624 3/4” T-1007 IPS X SWT 111124
Bronze Heating and Radiator Valves Mfr# description webb# Steam Angle Radiator Valves 110-103 1/2” T-431 IPS 81605 110-104 3/4” T-431 IPS 68791 110-105 1” T-431 IPS 11038 110-106 11/4” T-431 IPS 11039 110-107 11/2” T-431 IPS 80127 Hot Water Angle Valves 110-113 1/2” T-437 IPS 68792 110-114 3/4” T-437 IPS 68793 110-115 1” T-437 IPS 68794 110-116 11/4” T-437 IPS 72020 Radiator Gate Valves 110-135 1” T-435 IPS 68795 110-136 11/4” T-435 IPS 68796 Union Elbows 110-163 1/2” T-438 IPS 68799 110-164 3/4” T-438 IPS 68800 110-168 1” T-438 IPS 68801 110-169 11/4” T-438 IPS 68802 110-165 1/2” S-438 SWT 68803 110-166 3/4” S-438 SWT 68804
6 Hydronics/steam
For residential installations, mixes cold and hot water to extend capacity of water heater, storage tanks and hot water boiler tankless heaters. Features: • All brass or bronze construction. • Adjustable knob for temperature control. Specifications/Models: • Model 70A-F – Sizes 1/2”, solder connections, temperature range 120°–160°F. • Model 70A – Sizes 3/4”, solder connections, temperature range 120°–160°F. • Model L70A – Sizes 1/2”, solder connections, temperature range 100°–130°F.
Valves
Balancing Valves Mfr# description webb# 110-154 3/4” S-439 C X C 68797 110-155 1” S-439 C X C 68798
Replacement Handles Mfr# description webb# 110-170 RAD Valve Handles 112610
F.W. Webb Company
67 3/23/08 8:58:38 PM
Valves
Accu-Flo
SECTION
SECTION
6
6
Zone Valves
Accu-Flo Balancing Valve
Low Voltage Zone Valves
• Modified venturi design. • Blow-out proof system. • Ball valve construction. • Calibrated nameplate for presetting. • Built-in drain port. • All brass interior parts. • Rated to: 11/2” – 2”: 300 psi, 250°F. 21/2” – 4”: Class 125.
V8043 Two-Position Normally Closed Zone Valves
mfr# ACUF-075-AC ACUF-100-AC ACUF-125-AC
V8043B1029
size & Connection webb# 3/4” Sweat 253479 1” Sweat 253480 11/4” Sweat 253481
Two-way ON-OFF low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. • All models may be installed without disassembling the valve. • Complete powerhead may be removed or replaced without breaking water line connections or draining the system. • Actuator motor may be replaced without removing valve body or draining the system. pipe connections Mfr # V8043A1011 V8043A1029 V8043E1012
type
flow capacity
electrical connections
1/2”
18” Leads
3/4”
V8043E1020
1”
V8043E1061
3/4”
V8043E1079
1”
V8043E1028
1/2”
V8043F1036
3/4”
V8043F1051
1”
3.5 Cv
WEBB# 99622 83080 80682 80683
Sweat
105843
8 Cv
With End Switch
84886 106724
3.5 Cv
30231 31376
Zone Valve Replacement Head
Balance Sweat Valves
Mfr #
400D3916-048 E180W
Description
Electrical rating
electrical connections
WEBB#
Replacement Head for V8043 with End Switch
24 Vac, 50/60 Hz
Screw Terminal Block
69631
Replacement Motor Only
24 V
—
69632
V8043 Two-Position Normally Open Zone Valves
Two-way ON-OFF low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water, and some models for steam. • All models may be installed without disassembling the valve. • Complete powerhead may be removed or replaced without breaking water line connections or draining the system. • Actuator motor may be replaced without removing the valve body or draining the system. • Manual opener is not included in normally open valves.
body webb# Bronze 11053 Bronze 11054
6 Hydronics/steam
Amtrol Balancers are precision-machined valves designed for controlling the amount of liquid in individual lines within a system. Balance is set by the location of the lever, which turns a precision-fitted diverter in the valve body to reduce the flow through the valve. The diverter stem packing is heat resistant and need not be removed when connection are being soldered. • Bronze construction. • Packing does not need to be removed for soldering. • Precision lower adjustment. mfr# size BR1 1/2” BR2 3/4”
size
pipe connections Mfr # V8043B1027
size
type
electrical connections
WEBB#
3/4”
Sweat
18” Leads
88050
V8044 Two-Position Diverting Zone Valves
F.W. WEBB stocks Petite Baseboard. V8044A1044
Three-way diverting low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water, and some models for steam. • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. • All models may be installed without disassembling the valve. • Complete powerhead may be removed or replaced without breaking water line connections or draining the system. • Actuator motor may be replaced without removing the valve body or draining the system. pipe connections Mfr # V8044A1044 V8044E1011
68 6_Hydronics-Steam_p83.indd 68-69
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
size
3/4”
type
Sweat
electrical connections
WEBB#
18” Leads
100957
With End Switch
106177
F.W. Webb Company
69 3/23/08 8:58:58 PM
SECTION
SECTION
6
6
Zone Valves Line Voltage Zone Valve
ESP Zone Valves™
V4043
The heart of the ESP Zone Valve™ is the Energy Storage Principle. The ESP is a gear driven, capacitor powered valve. Its unique, patented technology replaces the typical spring with a Prostar Gold Cap Capacitor for returning the valve to its normal position. Moreover, the old style synchronous AC motor has been replaced with an exceptionally reliable high torque, high efficiency miniature motor. These Taco innovations replace two failure items, the synchronous motor and the spring, to deliver dependability. When a thermostat calls, the processor makes sure the capacitor is fully charged, then sends power to the motor. Once at the Open position, the motor turns off. The LED remains lit as long as the thermostat is calling. One the zone has been satisfied, the capacitor discharges some of its stored energy and the motor turns the ball to the Closed position.
On-OFF and diverting line voltage valves consist of an actuator motor and valve assembly for controlling the flow of hot or chilled water. • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. • All models may be installed without disassembling the valve. • Complete powerhead may be removed or replaced without breaking line connections or draining the system. • Motor can be replaced without removing the valve body or draining the system. • Suitable for heating and cooling applications.
V4043
Zone Valves
Mfr #
application type
V4043A1010
valve size
1/2”
Water
V4043A1259
Pipe connections
3/4”
Flare Sweat
ESP Zone Valve
WEBB#
Mfr #
102957
E050C
106214
E075C
40003918-006
valve size
Pipe connections
Conversion kit for converting old style valve bodies to accept 40003916 Actuator. Includes brass plate with drive shaft and rubber ball, large O-ring and four screws.
Two-way V8043A,E,F: V4043A, water valve body
561-5
571-2
Mfr #
tubing size (I.D.)
24v AC Thermostate circuit rating
WEBB#
1311-102
3/4”
0.4A
74483
Mfr #
tubing size (I.D.)
24v AC Thermostate circuit rating
WEBB#
1361-102
3/4”
0.2A
74482
WEBB#
By-Pass 3-Way. 125 psi, 55’ Pump Head
3/4” Sweat
80045
1/2” Sweat
79424
3/4” Sweat
24925
1” Sweat
24926
11/4” Sweat
24927
Transformer for 3 Zone Valves
24930
Standard 2-Way, 125 psi, 55’ Pump Head
description
WEBB#
F19-0097
Motor Assemblies: For 1311-102, -103, -104 For 1361-102, -103, -104 Water seal replacement kit not included
74489
6
Zone Valve Thermostat Application 24 Volt Thermostat
size & Type connections webb# Thermostat (1) 30340
Zone Valve Controls Taco switching relays combine clearly labeled PC board layouts with advanced features that allow for total system customization. External indicator lights provide instant diagnostic feedback, making a snap of service calls or new installation start-ups. All switching relays are UL and CSA listed, use standard “ice cube” replaceable relays, and are compatible with conventional and programmable thermostats. EXP Switching Relays can be expanded up to 20 zones with priority. Switching Relays are available in one, two, three, four and six zones. mfr# description webb# ZVC403 3 Zone Valve Control 165792 ZVC404 4 Zone Valve Control With Priority 165793 ZVC405 5 Zone Valve Control 165794 ZVC406 6 Zone Valve Control With Priority 165795
Zone Valves Mfr #
Zone Valve Transformer
mfr# description webb# 551-078RP Power Head f/551, 552, 553 69779 555-050RP Power Head f/570 Series 34894 AN024Q4A1 ESP NO/NC Actuator Head 251775
Parts & Accessories
6_Hydronics-Steam_p83.indd 70-71
size & type connections
Zone Valves
ZVC404
F.W. Webb Company
application
Replacement Parts
2-Wire, 24V valves with screw terminal wiring panel and auxiliary switch
70
242523
569-2
mfr# 568-19
3-Wire, 24V valves with screw terminal wiring panel and auxiliary switch
F84-0433
1” Sweat
Hydronics/steam
Two types of valves, 2-wire or 3-wire, for zoning hydronic systems up to 50 PSI. Features: • Self aligning barrel-type stem uses line pressure to seal off without binding on opening and closing. • Valve stem made of stainless steel. • Automatic recycling manual operator shows valve position at all times.
F84-0433
242522
573-2
571
Valve Assemblies: For 1311-102, 1361-102 (3/4”)
252725
3/4” Sweat
570-2
69630
Hydronic Zone Controls
F19-0104
1/2” Sweat
ESP 2-Way. NO/NC 24 VAC, 300 psi
Mfr #
WEBB#
Hydronic Controls
F19-0097
WEBB#
Heat Motor Zone Valves
572-2
1311-102
size & type connections
E100C
Conversion Kit for Valves Mfr #
application
Zone Valve Controls with PowerPort Option
74490 74491
ZVC404-EXP
www.fwwebb.com
mfr# description webb# ZVC404-EXP 4 Zone Valve Control with Priority & 2 Power Ports 255092 ZVC406-EXP-2 6 Zone Valve Control with Priority & 2 Power Ports 360216
The F.W. Webb Heating Catalog
F.W. Webb Company
71 3/23/08 8:59:39 PM
SECTION
SECTION
6
6
Flow Control Valves Bell & Gossett
Flo-Control™ Valves Prevent gravity flow in forced hot water systems and permit summer/winter operation of indirect water heaters. • Removeable top cap allows easy cleaning and service without removing pipe connections. • Manual operating position for vertical lift disc to permit gravity circulation. mfr# Part # webb# SA3/4 107034 55268 SA1 107108 55269 SA11/4 107019 53631 SA11/2 107020 467 SA2 107021 468 SB3/4 107024 73183
Bell & Gossett
Circuit Setter® “RF”
Calibrated Balance Valves for Low Flow Applications
mfr# Part # webb# RF-3/4S 117411 111271
72 6_Hydronics-Steam_p83.indd 72-73
F.W. Webb Company
Copper Manifolds – ALB
Bell & Gossett
Available with 3”, 4”, & 6” on center and standard, barbed or swedged ends!
Circuit Setter® Plus Calibrated Balance Valves with NPT and Solder Connections
The Bell & Gossett Circuit Setter Plus calibrated balance valve is a precision machined ball type, triple purpose balancing instrument. It is precisely calibrated for use as a presettable balance valve, variable orifice flow meter and positive shut-off service valve. Valves are furnished with a calibrated nameplate and memory stop indicator which permits the valve to be preset to a fixed open position and then closed for service without disturbing valve setting. Construction Body: Bronze Ball: Brass Seat Rings: Glass and Carbon filled TFE Readout Valves: Brass with EPT check valves Stem “O” Ring: EPDM Maximum Working Pressure NPT Models: 300 psig Sweat Models: 200 psig Mfr #
Part #
Size
Conns.
CB-1/2S
117412
1/2
199863
CB-3/4S
117413
3/4
165900
CB-1S
117401
1
CB-11/4S
117402
11/4
Sweat
WEBB#
11/2
202614
2
202615
CB-1/2
117414
1/2
76559
CB-3/4
117415
3/4
76560
CB-1
117416
1
76561
CB-11/4
117103
11/4
CB-11/2
117104
11/2
CB-2
117105
2
76564
CB-21/2
117106
21/2
111269
76562 76563
111270
Copper Red Ring Monoflo® Fittings Copper Red Ring Monoflo Fittings let you use a single pipe to serve as both supply and return main. • Connect risers to the main, assuring proper diversion of water to each heating unit regardless of type and its position in the system.
Copper Manifolds with Standard Ends CC100 50 24 1 X 1/2 X 24 BR
3”
191815
CC100 75 24
1 X 3/4 X 24 BR
3”
209014
Part# size webb#
CC125 50 24
11/4 X 1/2 X 24 BR
3”
190876
108119
3/4” X 1/2”
455
CC125 75 24
11/4 X 3/4 X 24 BR
3”
190877
108120
1” X 1/2”
456
CC150 50 24
11/2 X 1/2 X 24 BR
3”
223340
108121
1” X 3/4”
457
CC100 50 18
1 X 1/2 X 18 BR
4”
191816
108122
11/4” X 1/2”
458
11/4” X 3/4”
459
11/2” X 3/4”
460
CC100 75 18
1 X 3/4 X 18 BR
4”
241217
108123
CC125 75 18
11/4 X 3/4 X 18 BR
4”
209015
108124
CC100 50 12
1 X 1/2 X 12 BR
6”
190876
CC100 75 12
1 X 3/4 X 12 BR
6”
241190
CC125 75 12
11/4 X 3/4 X 12 BR
6”
192193
CC125 50 24 FS
117404
3
ctr to ctr webb#
166711
117403
117107
size
192558
CB-11/2S
CB-3
mfr#
Copper Manifolds with Female (Swedged) Branch Ends CC100 50 24 FS 1 X 1/2 X 24 F SW 3” 224314
CB-2S
NPT
All manifolds are Type L copper, 6’ in length with a branch every 3”, 4”, or 6” on center. Contractor cuts to fit each application. Perfect for boiler header, zone manifolds, return manifolds or radiant manifolds.
Bell & Gossett
11/2 X 1/2 X 24 F SW
3”
221190
Monoflo® Fitting
6 Mono-Flow Tees
Hydronics/steam
The Bell & Gossett Circuit Setter “RF” calibrated balance valve is a precision machined ball type, triple purpose balancing instrument. It is precisely calibrated for use as a presettable balance valve, variable orifice flow meter and positive shut-off service valve for low flow applications. Valves are furnished with a calibrated nameplate and memory stop indicator. This permits the valve to be preset to a fixed open position and then closed for service without disturbing valve settings. Construction Body: Bronze Ball: Brass Seat Rings: Glass and Carbon filled TFE Readout Valves: Brass with EPT check valve Stem “O” Ring: EPDM Maximum Working Pressure Sweat Models: 200 psig
Manifolds & Heaters
mfr# description webb# 302-203 3/4” X 1/2” T-570 C X C 73369 302-205 1” X 3/4” T-570 C X C 73370 302-207 11/4” X 3/4” T-570 C X C 73371
Steel Boiler Headers mfr# description webb# 06703
11/4” X 1”, 2 Zone
91036
06704
11/4” X 1”, 3 Zone
91037
06705
11/4” X 1”, 4 Zone
91038
06700
11/4” X 3/4”, 2 Zone
95148
06701
11/4” X 3/4”, 3 Zone
95149
06702
11/4” X 3/4”, 4 Zone
95150
Flo-Checks mfr# Part # webb# 218-3 3/4” IPS Unviersal (C.I.) 30339 219-4 3/4” Horizontal (Bronze) 24888 241-4 1” Horizontal (Bronze) 24889 220-6 1’ Universal (C.I.) 24890 221-6 11/4’ Universal (C.I.) 24891 222-6 11/2’ Universal (C.I.) 24892 223-5 2’ Universal (C.I.) 24893
F.W. Webb is a master distributor of bradford white water heaters! www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
73 3/23/08 8:59:56 PM
SECTION
SECTION
6
6
Baseboard Petite 7
Baseboard Petite 9
®
Residential Hydronic Baseboard Radiation
High Capacity Baseboard Radiation Petite 9® Packages
Petite 7 hot water baseboard radiation offers the decorating advantages homeowners want most . . . the ease of assembly installing contractors demand . . . plus the performance excellence that assures long-term customer satisfaction.
Assembled Baseboard
• Low profile design. • Simple installation. • Superior performance.
Petite 7
Petite 7® Accessories
Petite 7® Packages Assembled Baseboard mfr# P77A2 P77A3 P77A4 P77A5 P77A6 P77A7 P77A8 P77A10
size Webb# 2’ X 3/4” 76168 3’ X 3/4” 24617 4’ X 3/4” 24616 5’ X 3/4” 24615 6’ X 3/4” 24614 7’ X 3/4” 24613 8’ X 3/4” 24612 10’ X 3/4” 67311
mfr# P7C3 P7C4 P7C5 P7C6 P7C7 P7C8
size webb# 3’ 24623 4’ 24622 5’ 24621 6’ 24620 7’ 24619 8’ 24618
Includes front panel, back panel, damper with pivot, hanger brackets all assembled and shipped in a single carton, 2” splicer set included with each 5’, 6’, and 8’ length.
Element Only mfr# 7ME4-2 7ME4-3 7ME4-4 7ME4-5 7ME4-6 7ME4-7 7ME4-8
size webb# 2’ X 3/4” 151644 3’ X 3/4” 24629 4’ X 3/4” 24628 5’ X 3/4” 24627 6’ X 3/4” 24626 7’ X 3/4” 24625 8’ X 3/4” 24624
Each carton contains four elements plus necessary plastic glides.
mfr# desc. webb# End Covers P105 3”, Right Hand 91183 P106 3”, Left Hand 91184 Hinged Valve End Cover P83 4”, Right Hand 24632 P84 4”, Left Hand 24633 Hinged Inside Corner P89 90° 24634 P90 135° 24635 Hinged Outside Corner P93 90° 24636 P94 135° 24637 Wall Trim P95 4” 24638 Splice Strip (3 pieces) P96 2” 24639 P97 7” 24640 P98 14” 24641 Tubing Support Hanger P102 Supply 24645 P103 Return 24646 Hanger Bracket P104 Snap In 24643
Baseboard Ratings
I=B=R Hot Water Ratings – Forced Circulation Based on 65° F Entering Air Temperature P77A Assembly with 3/4” Element (I=B=R Rated) Flow rate
GPM 4 1
BTUH per linear foot of active length at average water temperatures indicated °F
150° 155° 160° 165° 170° 175° 180° 185° 190° 195° 200° 205° 210° 215° 220° 225° 230° 235° 240° 410 440 480 510 540 570 600 630 670 700 730 760 800 840 870 900 930 960 990 390 420 450 480 510 540 570 600 630 660 690 720 760 790 820 850 880 910 940
Petite 9
mfr# P9CU100-2 P9CU100-3 P9CU100-4 P9CU100-5 P9CU100-6 P9CU100-7 P9CU100-8
Model P9CU75 complete assembled units (single pack) include one length each of back panel, front panel, damper-louver and 3/4” heating element. 10 GA. front panel, plus required support brackets and element cradle expansion clips. Panel joiner included with 5’, 6’, & 8’ lengths.
6_Hydronics-Steam_p83.indd 74-75
F.W. Webb Company
www.fwwebb.com
mfr# P9CO-2 P9CO-3 P9CO-4 P9CO-5 P9CO-6 P9CO-7 P9CO-8
size webb# 2’ 24597 3’ 24596 4’ 24595 5’ 24594 6’ 24593 7’ 24592 8’ 24591
Model P9CO enclosure only assembled (single pack), includes one length each of back panel, 18 GA front panel, damper-louver and 1” heating element, plus required support brackets and element cradle expansion clips. Panel joiner included with 5’, 6’, & 8’ lengths. Element Only mfr# E75-2 E75-3 E75-4 E75-5 E75-6 E75-7 E75-8
size webb# 2’ X 3/4” 24590 3’ X 3/4” 24589 4’ X 3/4” 24588 5’ X 3/4” 24587 6’ X 3/4” 24586 7’ X 3/4” 24585 8’ X 3/4” 24584
mfr# desc. webb# Hinged End Caps P9-REC 4”, Right Hand 24598 P9-LEC 4”, Left Hand 30322 Hinged Valve End Cap P9-VECR 6”, Right Hand 24599 P9-VECL 6”, Left Hand 30323 Hinged Inside Corner P9-IC 90° 24600 P9-ICB 135° 24601 Hinged Outside Corner P9-OC 90° 24602 P9-OCB 135° 76170 Wall Trim P9-WJ 4” 179521 Standard Panel Joiner P9-PJ 2” 24606 Fill In Section P9-FIS 14” 76173 Return Tube Hanger P9-RTH Upper 24608 Support Bracket P9BR 76172
E75 3/4” CU tube elements only elements and cradles individually boxed.
Baseboard Ratings
6
model# Flow rate hot water — BTU/HR./Lin.ft. Rate LB./HR. 140° 150° 160° 170° 180° 190° 200° 210° 220° P9 3/4” 2000 470 560 650 750 850 940 1040 1140 1240 P9 3/4” 500 445 530 620 710 800 890 980 1080 1170
Design Line is made of durable, rust proof, corrosion resistant extruded aluminum. It’s perfect for high moisture areas such as bathrooms. Durable, Long Lasting—Design Line construction is of sturdy extruded aluminum with locking die cast accessories. All are finished with baked-on enamel paint. Design Line can take abuse from vacuum cleaners, mops, and brooms with no dents or dings. Slim, Low, Silhouette—Design Line takes the bulk out of baseboards. Mounts close to the wall and rises only 6 1/2 off the floor. Design Line gives you more freedom for furniture placement. mfr# Bath3 Bath4 Bath5
74
size webb# 2’ X 3/4” 24583 3’ X 3/4” 24582 4’ X 3/4” 24581 5’ X 3/4” 24580 6’ X 3/4” 24579 7’ X 3/4” 24578 8’ X 3/4” 24577
Enclosure Only
Petite 9 ® Accessories
Hydronics/steam
Includes front panel, back panel, damper with pivot, hanger brackets, and heating element with plastic glides all assembled and shipped in a single carton, 2” splicer set included with each 5’, 6’, and 8’ length.
Enclosure Only
®
The F.W. Webb Heating Catalog
DESCRIPTION webb# 3’ Design Line Kit 257722 4’ Design Line Kit 257723 5’ Design Line Kit 257724
F.W. Webb Company
75 3/23/08 8:59:57 PM
Tankless Coils
Freestanding Option: All vertical models are now available as a freestanding unit on forced circulation installations. When ordering, specifiy “FM” for floor mount before model no.
SECTION
SECTION
6
6
Everhot External Tankless Water Heaters
Onix™ Radiant Hose
Everhot External Tankless Water Heaters service a wide range of domestic, commercial, and industrial applications — virtually anywhere there is a requirement for instantaneous hot water on demand. Capacities range from 4 gallons per minute to 125 gallons per minute. Models are available in both vertical and horizontal styles, with special models for radiation heaters, swimming pool heaters, indirect tank heaters, and converter applications. Standard Features: • Solid copper shell. • Reinforced copper, integral finned tubing. • Air vent coupling. • Attractive red jacket. • Three year warranty.
Onix Staple Up™ is the fastest, quietest, least expensive, and most hassle free way to install under floor radiant heating. Onix conducts heat through the flooring to warm your room quietly and evenly without changing your finished floor height. No need to install aluminum plates with this application. They’re simply not needed.
weight (lbs)
Sq. Ft. heat surface
female boiler fittings
male domestic water fittings
No. 6 “Deluxe”
37
17.43
2”
1/2”
123/4”
153/4”
8647
No. 8 “Deluxe”
43
23.98
2”
3/4”
123/4”
173/4”
8648
No. 10 “Super”
51
30.23
2”
3/4”
123/4”
193/4”
8649
Model #
diameter
jacket height
Webb #
Onix Fittings
Trufin Tube Tankless Heaters mfr# Boiler Series
Description GPM Webb#
V1-5
5” X 121/4” – 8 BH
5
National- U.S. (17-18, 70-101-109-209, 300) Crane (2-8-11-12, 202-300-302) 71/4” Dia. – 6 BH 5 Thatcher (G-OP)
77654
8630
SelfTite™ Clamps mfr# description webb# Onix SelfTite 663019-10 3/8” 68296 663022-10 1/2” 110640 663025-10 5/8” 88446 663029-100 3/4” 88440 6643244-10 1” 378859
Onix Couplings For making field repairs. Use Onix Couplings to make field repairs and connections when necessary. Be sure to use Watts Radiant’s SureClamps or SelfTities when making all field splice repairs and closely follow all guidelines. Order clamps separately. mfr# description webb# 677062-10 3/8” Onix Coupling 268945 677182-10 1/2” Onix Coupling 378860 677101-10 5/8” Onix Coupling 242627 677121-10 3/4” Onix Coupling 218873 677122-10 1” Onix Coupling 378861
Onix Elbow Fittings
For connecting Onix supply lines to baseboard or fan coils. Use these new Onix Elbow Fittings to make transitions to baseboards, radiators, or fan coils when using Onix as supply/return piping. Onix elbows make a neat, professional connection. Onix’s flexibility make it the preferred product for fast, easy connections, especially in retrofit applications. mfr# description webb# 185075-10 3/4” Onix x 3/4” Elbow 251571 185074-10 1/2” X 3/4” F SWT 263363 185625-10 5/8” X 3/4” F SWT 264421
Onix Stainless Steel T20 Fittings mfr# description webb# P689001-10 3/8” Onix X 3/4” BSP 253019 P689002-10 1/2” Onix X 3/4” BSP 283494
Onix Unwinder PE-5
Peerless (JO, JOT, 2, 2T)
61/4” X 141/4” – 12 BH
5
91059
SelfTite Pliers mfr# description webb# 669100 SelfTite Pliers 233449
8639
PF-5
Peerless (JO, JOT, EC, 2-2T, 7-7PF, 60-61-81, 8” Dia. 8 BH WB, LC/LCE)
5
ECT-5
Peerless (ECT-Steam)
51/8” c 11” – 8 BH
5
8635
TR-5
Trianco (Newport Horizon, DBC)
71/2” X 71/2” – 8 BH
5
69930
WE-624 WE-625 WE-626 G05
Weil-McLain (65-66-68-EG) Weil-McLain (42-62) 7” Dia – 8 BH Weil-McLain (Water Boilers – Specify Series) Weil-McLain (Gold) 73/4” Dia – 6 BH
4 5 6 5
92504 8618 8619 94757
65-S-5 Weil-Mclain (65-66-68–EG–Gold Steam Boilers)
6” X 10” – 8BH
5
8622
Other sizes/models available.
76 6_Hydronics-Steam_p83.indd 76-77
F.W. Webb Company
www.fwwebb.com
SelfTite Onix Repair Kits
Each SelfTite Repair Kit contains two double-ended barbs and four clamps in a kit. Each kit includes instructions to help insure that the repair is done properly. Be sure to pressure test the repair after work is performed.
6
Watts Radiant’s Onix Unwinder allow Onix coils to be quickly and easily unwound for easier and faster hose layout of the jobsite. The center post allows the Onix coil to move around without sliding off the Unwinder. Heavy-duty ballbearing construction means years of use and easy turning. mfr# description webb# 669231 Onix Hose Unwinder 84295
Hydronics/steam
T105
Burnham (V-1, V-7, V-9 – Specify Series)
mfr# description webb# 086061-160 3/8” X 160 Onix 68294 086061-180 3/8” X 180 Onix 68293 086061-200 3/8” X 200 Onix 68292 086081-50 1/2” X 50 Onix 210639 086081-200 1/2” X 200 Onix 68341 086081-300 1/2” X 300 Onix 165588 086101-50 5/8” X 50 Onix 204433 086101-100 5/8” X 100 Onix 204434 086101-300 5/8” X 300 Onix 192983 086121-50 3/4” X 50 Onix 76508 086121-100 3/4” X 100 Onix 90560 086161X-50 1” X 50 Onix 378858
Radiant
mfr# description Packaging webb# 660075 3/8” Onix SelfTite 2 Splices, 4 SelfTites 68298
Onix Barbs
For transitioning Onix to sweat fittings. Sweat Onix Barbs into copper tees or ball valves for easy field manifold connection. mfr# description webb# 684001-10 3/8” Onix X 1/2” Fitting Barb 68295 685001-10 1/2” Onix X 1/2” Fitting Barb 68344 686001-10 5/8” Onix X 1/2” Fitting Barb 88444 687001-10 3/4” Onix X 3/4” Fitting Barb 76507 688001-10 1” Onix X 1” Fitting Barb 194795
The F.W. Webb Heating Catalog
F.W. Webb carries Watts Radiants’ in-floor heating and snow melting products!
F.W. Webb Company
77 3/23/08 9:00:11 PM
SECTION
SECTION
6
6
Radiant Radiant PEX
Crimp X Male NPT Adapters
Radiant PEX Coils
mfr# description webb# PCMC33X-10 1/2” Crimp X 1/2” MPT 155494 PCMC44X-10 3/4” Crimp X 3/4” MPT 155496 PCMC55X-10 1” Crimp X 1” MPT 223666
For heating and snowmelting. Cross-linked polyethylene tubing manufactured with an EVOH oxygen barrier. All sizes are manufactured to ASTM F-876 and F-877 standards and to SDR-9 dimensions. E-PexB is durable, flexible, and has excellent flow characteristics. mfr# description webb# PB032061-600B 3/8” — 600’ 247399 PB032081-100B 1/2” — 100’ 155403 PB032081-300 1/2” — 300’ 273855 PB032081-600B 1/2” — 600’ 204253 PB032081-1000B 1/2” — 1000’ 223342 PB032101-600B 5/8” — 600’ 179259 PB032121-100B 3/4” — 100’ 194260 PB032121-600B 3/4” — 600’ 194258 PB032161-100 1” X 100’ 273865 PB032181-100 11/4” X 100’ 378865 PB032201-100 11/2” X 100’ 378866
Radiant Pex Sticks mfr# description webb# 81007368 3/4” and 20” Stick 318652 81007367 1” and 20” Stick 318653
Crimp X Crimp Brass Couplings mfr# description webb# PCC22X-10 3/8” Crimp Coupling 155481 PCC33X-10 1/2” Crimp Coupling 155482 PCC66X-10 5/8” Crimp Coupling 263150 PCC44X-10 3/4” Crimp Coupling 155484 PCC55X-10 1” Crimp Coupling 252496 PCC77X-10 11/4” X 11/4” Crimp Coupling 269339
Crimp X Male Sweat (copper fitting) Adapters mfr# description webb# PC637X-10 3/8” Crimp X 1/2” Male Sweat Adapter 155451 PC650X-10 1/2” Crimp X 1/2” Male Sweat Adapter 155453 PC660X-10 1/2” Crimp X 5/8” Male Sweat Adapter 263147 PC670X-10 3/4” Crimp X 5/8” Male Sweat Adapter 263148 PC675X-10 3/4” Crimp X 3/4” Male Sweat Adapter 155455 PC700X-10 1” Crimp X 1” Male Sweat Adapter 256252 PC725X-10 11/4” Crimp X 11/4” Male Sweat Adapter 378867
Crimp X Female Sweat (copper) Adapters mfr# description webb# PC750X-10 1/2” Crimp X 1/2” Female Sweat Adapter 155458 PC775X-10 3/4” Crimp X 3/4” Female Sweat Adapter 155470 PC780X-10 1” Crimp X 1” Female Sweat Adapter 269333 PC785X-10 11/4” Crimp X 11/4” Female Sweat Adapter 269334
78 6_Hydronics-Steam_p83.indd 78-79
F.W. Webb Company
Crimp X Female Sweat (Copper Fitting) Elbow mfr# description webb# PCE34-10 1/2” Crimp X 3/4” Female Sweat Elbow 255116 PCE64-10 5/8” Crimp X 3/4” Female Sweat Elbow 283046 PCE44-10 3/4” Crimp X 3/4” Female Sweat Elbow 254528
Crimp X Crimp Elbows (Equal Elbows) mfr# description webb# PCE33X-10 1/2” Crimp X 1/2” Crimp Elbow 155440 PCE44X-10 3/4” Crimp X 3/4” Crimp Elbow 155442 PCE55X-10 1” Crimp X 1” Crimp Elbow 252489 PCE77X-10 11/4” Crimp X 11/4” Crimp Elbow 378868
PEX Swivel Crimp Fittings CazzBrass Crimp Swivel Fittings mfr# description webb# P689001-10 3/8” X 3/4” BSP Fitting 253019 P689002-10 1/2” X 3/4” BSP Fitting 283494
PEX Compression Fittings SS-T20F PEX Compression Fittings mfr# description webb# PX690001-10 3/8” SS-T20F PEX Compression Fitting 244196 PX690002-10 1/2” SS-T20F PEX Compression Fitting 244197 PX690003-10 5/8” SS-T20F PEX Compression Fitting 244198 PX690004-10 3/4” SS-T20F PEX Compression Fitting 251420
Mid-run Bend Supports
Helps make bends in walls and joist cavities. mfr# description webb# PSBM33X-10 3/8” and 1/2” Mid-run Bend Supports 209453 PSBM55X-10 5/8” and 1/2” Mid-run Bend Supports 243255
Terminal Bend Supports
The RadiantPEX-AL Advantage. RadiantPEX-AL is a composite pipe engineered for radiant floor heating. It’s proven, long lasting and maintenance-free. Installers like it because it’s lightweight, durable and can be shaped to fit any jobsite. The aluminum layer protects boiler systems against corrosion and it has superior temperature and pressure ratings. The RadiantPEX-AL Is Built to Last. RadiantPEX-AL pipe and fittings are manufactured to American Standard Testing Methods for requirements and test methods for materials, workmanship, dimensions, environmental stress cracking, sustained hydrostatic pressure strength, thermo-cycling resistance and bend strength, among other tests. RadiantPEX-AL meets or exceeds these specifications. The RadiantPEX-AL Press Fittings. Watts Radiant’s line of Press fittings offers a clean, reliable method of connections for RadiantPEX-AL. The Stainless Steel sleeve creates a permanent, unyielding union on the outside, while the double O-rings form a dependable internal seal. A polyethylene insulator protects against corrosion between brass and aluminum pipe layers. Choose from a wide variety of fitting styles and sizes to suit your needs and use just one tool to make all your connections. Press fittings are listed by NSF to NSF-PW and NSF-rfh and carry the UPC mark.
RadiantPEX-AL Coils RadiantPEX-AL is a PEX-AL-PEX tubing. It can be shaped to fit any job-sote condition. Use it for all floor heating and snow melting, as well as supply piping for other hydronic applications. Also available in sticks. mfr# description webb# RL08-300-OR RadiantPEX-AL, 1/2” X 300’ Coil 361074 RL08-1000-OR RadiantPEX-AL,1/2” X 1000’ Coil 361076 RL10-300-OR RadiantPEX-AL, 5/8” X 300’ Coil 361077 RL12-100-OR RadiantPEX-AL, 3/4” X 100’ Coil 361079 RL16-100-OR RadiantPEX-AL, 1” X 100’ Coil 361082
RadiantPEX-AL Compression Fittings RadiantPEX-AL SS-T20 (3/4” FBSP) Compression Fitting mfr# description webb# RLC01B08T20 Adapter, SS-T20 (3/4” FBSP) X 1/2” Compression 361260
6 Hydronics/steam
PEX Crimp Fittings
Radiant PEX-AL
Radiant
The RadiantPEX-AL Compression Fittings. The RadiantPEX-AL fitting system from Watts Radiant is as simple as it looks. All you need is a box-end wrench to tighten the nut. Made of solid brass, these fittings are for long, trouble-free service. Double O-rings and a brass compression ring insure a leak-proof connection. A polyethylene insulator protects against corrosion between brass and aluminum pipe layers. Compression fittings are listed by NSF to NSF-rfh.
Helps pipe transition out of the slab. mfr# description webb# PSB23X-10 3/8” and 1/2” Terminal Bend Supports 204603 PSB45X-10 5/8” and 3/4” Terminal Bend Supports 209454
PEX Plates
F.w. webb stocks
Aluminum plates for underfloor & sandwich applications. PEX Plates are the traditional way to install PEX in underfloor and sandwich applications. mfr# description webb# P700524-100 PEX Underfloor Plates 5” X 24” 251425 P700250-20 Extruded Aluminum Plate 31/2” X 48” 361601
www.fwwebb.com
Products. The F.W. Webb Heating Catalog
F.W. Webb Company
79 3/23/08 9:00:35 PM
SECTION
SECTION
6
6
Radiant
Radiant
Radiant CinchClamp
Onix CustomCut Manifolds
Stainless Steel Manifolds
Manifold End Cap
These connections are a cinch to make.
M-16 CustomCut
1” and 11/2” Stainless Steel Manifolds
These Manifold End Caps are used to cap off the end of a stainless Steel manifold when a vent-purge assembly is not used. Nickel-plated brass. Sold individually.
Why it’s a cinch: • Ratcheting tool provides easy one-tool assembly. • Connections can be dry-fit. • Connections can be made with wet tubing. • Final connections take only seconds. • CinchTool only releases when connection is complete, ensuring a perfect connection. • Can visually verify whether connection is completed – tab of clamp is “pinched”. • Connection rated to 160 psi @ 73ºF; 100 psi @ 180ºF. • Clamp is an interlocking ring, forming a complete 360º uniform, watertight seal. • Corrosion resistant, annealed stainless steel. • Uses ASTM F1807 brass or ASTM F2159 plastic insert fittings (plastic for potable systems only). • Warning: To ensure a perfect seal, the PEX pipe must be above 32ºF when the CinchClamp is applied.
Priced as a single manifold, not in pairs.
These manifolds truly represent state-of-the art quality and design. Stainless Steel manifolds are made of heavy-walled, DIN-standard stainless steel tubing from Germany’s finest steel mills. This tubing is carefully milled and machined by CNC machines, and robotically welded to meet the most exacting professional standards.
mfr# description webb# 204237 3/8” x 1” Brass Truck x 48” Long 240626 204237BV 3/8” x 1” Brass Truck x 48” Long w/BV 244052
Radiant PEX CrimpRing™ CustomCut Manifolds CrimpRing M-16 CustomCut Manifolds, 1/2” Barbs
Stainless Steel Cinch Clamps mfr# description webb# PCCC2X-10 3/8” CinchClamps 274166 PCCC3X-10 1/2” CinchClamps 274181 PCCC6X-10 5/8” CinchClamps 274926 PCCC4X-10 3/4” CinchClamps 274183 PCCC5X-10 1” CinchClamps 274185
mfr# description webb# PCCR2X-100 3/8” CrimpRing 155477 PCCR3X-100 1/2” CrimpRing 155478 PCCR6X-100 5/8” CrimpRing 263151 PCCR4X-100 3/4” CrimpRing 155480 PCCR5X-100 1” CrimpRing 253172 PCCR7X-100 11/4” CrimpRing 269554
Radiant PEX Base Branch CustomCut Manifolds
mfr# description webb# 205250 1/2” Brass Base Branch M-16 X 1” Brass Trunk X 48” long 155165
mfr# description webb# P669231 PEX Unwinder 190243
Mini Ball Valve For balancing and system service; supplied loose for field installation. Mini Ball Valves allow you to purge, balance, isolate, and regulate the flow of fluid to each individual circuit or manifold. Order Onix fittings to match.
This new Valve Actuator is an optional feature for mounting directly to the balancing manifold. The Valve Actuator provides on/off flow control to individual radiant circuits. Actuator is 24 Vac with four wires to connect to the thermostat and circulating pump. mfr# description webb# PZ656104 Valve Actuator SS Manifold 244194
80 6_Hydronics-Steam_p83.indd 80-81
F.W. Webb Company
For connecting stainless manifolds to NPT fittings. mfr# description webb# D4201480N Transitional Fitting, 1” FBSP X 1” MNPT 251406
BSP to BSP Transition Fitting mfr# description webb# D3517020N Transition Elbow, 1” FBSP X 1” MBSP 319494
These 1” X 1” Manifold Couplings are used to connect two manifold pairs. For example, an M-4 can be connected to an M-3 using the coupler to make a M-7. Nickel-plated brass for corrosion resistance. Sold in pairs, or bags of 10 pairs.
Stainless Steel Manifold Accessories
mfr# description webb# D4201700-S Circuit Isolation Cap 251410
Circuit Isolation Mini Ball Valve
mfr# description webb# D4201725NR SS Trunk ISO Valve Red Handle 256486 SS Trunk ISO Valve Blue Handle
251403
Stainless Steel Manifold Pressure Test Kit
The F.W. Webb Heating Catalog
6
For unused circuits in stainless steel manifolds.
The Isolation Ball Valves with Temperature Gauges include gauges to measure supply and return temperatures in °F for troubleshooting or system balancing.
D4201730NR
mfr# description webb# D402178N 1” X 1” Manifold Coupling 251408
Circuit Isolation Plug
mfr# description webb# D665161 Flowmeter Manifold Pressure Test Kit 251424
www.fwwebb.com
BSP to NPT Transition Fitting
Add-a-Zones make it easy to add additional capacity to a manifold already installed. Just thread them onto the end of a manifold, or use them as a one-branch manifold (M-1).
Specially fitted for stainless steel manifolds.
mfr# description webb# 445332 1/2” Mini Ball Valve for 3/8” – 5/8” Barbs 218873
mfr# description webb# D4201715N Vent-and-Purge Assembly 251405
1” x 1” Manifold Coupling
Transitional Trunk Isolation Ball Valves with Temperature Gauge
Valve Actuator
The Vent-and-Purge Assembly allows purging of the zone at the manifold location. The Vent-andPurge Assembly consists of a 1” BSP sleeve nut for attaching to the end of the manifold, and a 3/8” manual air vent valve. Also includes a 1/2” hose fitting with a built-in ball valve to allow zone draining and filling. Nickel-plated brass. Sold Individually.
Add-a-Zone
mfr# description webb# D3804000SS Stainless Steel Add-A-Zone 1” 378864
Pex Unwinder Our Pex Unwinder handles all sizes of coils. The coil sits on the tripod and is held in place as it unwinds with four guide-bars. The PEX feeds through a guide-ring on top of the unwinder.
mfr# description webb# D3803002SS 1” Flowmeter Manifold, SS, 2-Outlet 251396 D3803003SS 1” Flowmeter Manifold, SS, 3-Outlet 251397 D3803004SS 1” Flowmeter Manifold, SS 4-Outlet 251398 D3803005SS 1” Flowmeter Manifold, SS 5-Outlet 378862 D3803006SS 1” Flowmeter Manifold, SS 6-Outlet 251399 D3803007SS 1” Flowmeter Manifold, SS 7-Outlet 378863 D3803008SS 1” Flowmeter Manifold, SS 8-Outlet 251400 D3803010SS 1” Flowmeter Manifold, SS 10-Outlet 251401 D3803012SS 1” Flowmeter Manifold, SS 12-Outlet 251402 D3807610SS 11/2” Flowmeter Manifold, SS 10-Outlet 368564
Vent-and-Purge Assembly
Hydronics/steam
Copper Crimp Rings
mfr# description webb# PC204250 1/2” CrimpRing M-16 X 1” Brass Trunk X 48” long 244053 PC204250BV 1/2” CrimpRing MBV M-16 X 1” Brass Trunk X 48” long 255324
Matching fittings and accessories are made of solid brass and heavily plated with nickel to match the appearance of the manifold trunk. Standard features include flow balancing valves and flow meters. Manifolds are sold in pre-mounted pairs.
mfr# description webb# D063064N Manifold End Cap 251404
For circuits on the supply manifold. The Circuit Isolation Mini-ball Valve is used to either positively shut-off a circuit, or to adjust the flow of a circuit on a manifold. Features a large handle for easy adjustment and control. Nickel-plated brass for corrosion resistance. May be used on any manifold with 3/4” BSP circuit threads (Stainless Steel Manifolds). mfr# description webb# D4201712-N Circuit Isolation Mini Ball Valve 251412
F.W. Webb Company
81 3/23/08 9:01:04 PM
mfr# description webb# 862HS1542 15 mm SubRay Header Stick 250394 862HS1842 18 mm SubRay Header Stick 250395
Sleepers
ClipTwister ScrewClip Tool
Install Aluminum Conduction Rolls above the sleepers, not below. Locating aluminum above the pipe reduces thermal striping. Try it and see for yourself. Each strip should be spaced about 1/2” apart, and installed perpendicular to the sleepers. Do not cover the header sticks with aluminum if your finish floor is nailed down. Use one roll for every 70 sq. ft. of heated floor.
The ClipTwister ScrewClip Tool is designed to install the ScrewClips easily into board-type insulation using a standard cordless drill. The ScrewClip is designed to hold 3/8” or 1/2” Onix, or 3/8”, 1/2” and 5/8” PEX. Simply screw the clip into the insulation, and snap the tubing into the clip.
mfr# description webb# 862ACS1650 862 Aluminum Cover 16” X 50’ 250387
C-Covers C-Covers (optional) are heavy steel covers that fit in the radiant channels. They come in 15 mm and 18 mm thickness. Typically used to protect supply/return lines that may run parallel to nailed strip flooring. Also used under superthin tile floors to support cement boards. Protects the tubing against errant mails or other fasteners. mfr# description webb# 862CC1848 862 C-Cover 18 mm (2” X 4’) 250389
Tools Basic Tubing Cutter
mfr# description webb# 862S1860 862 Sleepers, 18 mm (6” X 60”) 250397
Corner Sweeps Corner Sweeps are made of Group 1 Baltic Birch. This CNC-routed piece provides a nailing surface where the PEX turns a corner between the Header Sticks. Most rectangular rooms will need one or two sweeps per pipe circuit. For complex rooms see the SubRay Manual for guidance. mfr# description webb# 862 Corner Sweep, 18 mm (8” X 8”)
250391
Grippers Grippers are made of Group 1 Baltic Birch and are used for holding E-Pex tubing. Holds down with one screw. They are made to the same thickness as the Header Sticks and Sleepers. Not required for Onix. They are slightly less that 2” wide, so don’t used them for spacing the sleepers across the floor. Use two grippers for each PEX circuit, where it enters/leaves the floor. mfr# description webb# 862G18 862 Gripper, 15 mm 250393
82 6_Hydronics-Steam_p83.indd 82-83
F.W. Webb Company
mfr# description webb# PTC300 Cutter 269616
Cinch Tool mfr# description webb# 0651060 Cinch Tool 274186
Ratcheting Cinch Tool mfr# description webb# 0651059 Ratch Cinch Tool 372759
mfr# description webb# P667450 ClipTwister Screwtip Tool 244183 PAC1620 Foamboard ScrewClip 111524
Electric Floor Warming
Staple Guns & Staples
HeatWeave mats warm almost any floor covering. They work great in new construction or remodeling and in projects of any size.
mfr# description webb# 668510 Onix 3/8” Staple Gun 68301 P668509 PEX 1/2” Staple Gun 204414 668018-1660 Staples for both 3/8” & 1/2” 68302
Staple Gun Accessories mfr# description webb# 668515 Staple Gun Extention Arm Kit 250386 668521 Staple Plate Conversion Kit (3/8” Onix) 166064
NailTites For securing Onix to subfloors using a hammer. NailTites are used to hold Onix wherever a staple gun cannot get into a tight area. These NailTites are strong and easy to use. These NailTites can also be used for wires, pipe, or other unique installation applications. mfr# description webb# 691060-100 Onix 3/8” NailTites 68297 691083-100 Onix 1/2” NailTites 68346
mfr# description webb# 0650872 15” Crimpall Tool Kit 261726 0650879 19” Crimpall Tool Kit 269555 RLPAJ15-K1 15” Pressall Jaw Kit 361424
Foamboard Stapler The Foamboard Stapler is designed to staple 3/8” and 1/2” onix, and 3/8” to 3/4” PEX to a wide variety of foam insulation boards. The stapler comes fully assembled and used 1.6” and 2.4” plastic staples. Use 1.6” staples for 1” insulation boards, and 2.4” staples for 2” (or thicker) insulation boards. The Foamboard Stapler holds up to 120 staples. Reduce pipe installation time and increase productivity.
The best fastener for 3/8” and 1/2” underfloor PEX applications. Our LockDown Fastener is designed specifically for underfloor PEX applications. Its loose hold allows PEX to move during expansion and contraction of the tubing. Use LockDown for attaching 3/8” or 1/2” PEX; do not use it for 5/8” PEX as it will fit too tightly. Order five LockDowns for 10’ of PEX. Follow our Installation Guidelines carefully. The LockDown won’t pop open like other similar clips you may have seen. Try it and you’ll like it! mfr# description webb# P667100-100 PEX Lockdown Fastener, 3/8” –1/2” 243260
mfr# description webb# P667400 Stapler 241962 P667300-300 (300) 1.6” Staples 245750 P667350-300 (300) 2.4” Staples 243806 P667350-1200 (1,200) 2.4” Staples 243807
Heat Cold Rooms You can heat most rooms with a HeatWeave floor. Send in your plans for a free evaluation.
6
Feel Wonderful HeatWeave is true radiant heating. It feels like a gentle foot massage or a walk on a warm beach. Warm floors are also dry floors and that’s important in your bathroom, kitchen, or sunroom.
LockDown Fasteners
Crimpall Tool Kit
Warm Your Floors
Hydronics/steam
Sleepers are installed 2” apart to form the 2” radiant channels that hold the radiant tubing. Sleepers are made in two thicknesses, 15mm (for 3/8” PEX) and 18 mm (for 1/2” PEX and 3/8” Onix). Made with 11 laminations to ensure a precise fit on your radiant floor. Allow about 30 sleepers for each 100 sq. ft. of floor.
862CS18
Aluminum Conduction Roll
Radiant
t
Cabinet-grade Baltic Birch Header Sticks are used to hold loops of Pex at opposite ends of a room. Special Patent-pending design holds PEX without squeaking or popping. They are made in two thicknesses, 15 mm and 18 mm. Order 15 mm components for 3/8”; order 18 mm for 1/2” PEX or 3/8” Onix. They are built with 11 laminations and CNC routed to precise dimensions to give floor manufacturers to ensure fastener holding capacity. Each stick is 42” long and contains three bends (one bend pictured). If using strip hardwood flooring, run sticks the same way as (parallel to) the flooring. Allow for enough length of Header Sticks to run along two opposite walls.
6
t
Header Sticks
6
t
SubRay™ Radiant System
SECTION
t
Radiant
SECTION
Control Your Comfort Your HeatWeave FloorStat™ uses an underfloor sensor for selecting temperature selection. An optional Programmable FloorStat turns your system on and off based on your personal schedule. Both models contain a Ground Fault Circuit Interrupter (GFCI).
Contact your local F.W. Webb representative for ordering information.
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
83 3/23/08 9:01:42 PM
SECTION
SECTION
7
7
Burner & Blower Motors Oil Burner Motors
Taco Circulator Motors
Features: • Totally enclosed and semi-enclosed construction (semi-enclosed are totally enclosed except for shaft end). • Split phase or capacitor start designs. • Single phase. • Sleeve bearing. • Manual reset thermal protection. O600, O601, O004 • Electronically reversible. • NEMA M or N flange designs.
Split Phase MFR#
HP
RPM
O600
1/8
1725
O100
Encl.
amps
Nema frame
Webb#
2.8
48N
45616
115
TENV SemiEncl. TENV SemiEncl.
O601
1/6
O004
1/4
3450
2.5
48M
45615
2.7 4.8
45617
48N
70050
PSC Oil Burner Motors Permanent slip capacitor (PSC), lower amp draw, cooler operation, fewer failures and delivers more power. Ball bearings for longer life. description 1/7 HP 3450 HP, 115V Beckett AF II
webb# 208685 95780
webb# 222401 263169
Commercial Oil Burner Motor mfr# description For 201, 301 CRD, Carlin 27656S 1/4 HP, 115V, 60HZ, 1 Phase, 3450 rpm
MFR#
HP
B206
1/4
B207
1/3
B208
1/2
RPM
Volts
amps
1775
115
6.1
Nema frame
SERVICE FACTOR
5.0 7.2
45608
RPM
Volts
amps
D164
3/4
1725
115
10.0
56
45610
SERVICE FACTOR
Bell & Gossett
webb#
4.8
X002 1/3
7.8
X004 1/2 X009
3/4
1075
3
115
1.25
9.6 10.2
1725
115
Nema amps frame 2.7 3.0
SERVICE FACTOR
48Y
1.4
Description
Webb#
110 Circulator Motor Assembly, 1/2 HP
54554
Webb# 69856 69857
webb# 54553 69669
B & G Circulator Motors Series 100 booster pumps
45611
description
100 NFI
100 BI
100 AB
100 BHR
Webb#
Power Pack Motor
111034
111034
111034
111034
53634
Ring Motor Mount Set
118223
118223
118223
118223
53535
booster pumps
111034
description
HV NFI
NV BI
HV AB
HV BNFI
Webb#
Power Pack Motor
111061
111061
111061
111061
71975
description
1” PR
Webb#
Power Pack Motor
111031
71974
7
B & G Circulator Couplings H24-40W
5.0 Sleeve
1/8
Webb#
30 OV “A” MFR# HP RPM SPDS Volts amps BRG CAP DIM SHAFT Webb#
X000 1/4
1/12
Volts
mfr# description 110-009RP 110 Coupler TP425 110 Coupler
Split Phase, NEMA Service Factor HP
X700 X701
RPM
Taco Circulator Couplings
45609
1.25
MFR#
HP
MFR#
Webb#
1.35
48Y
Nema frame
MFR#
110-223RP
Features: • Permanent split capacitor. • Single phase. • Direct drive, air over. • Open enclosure. • Sleeve bearing. • Automatic reset thermal protection. • 21/4” resilient rings. • 21/2” enlarger bands included. • 1/2” x 4” shaft with flat. • 11/2” extended thru bolts. • Grommeted lead exit. • 36” leads. • Reversing plug.
Permanent slip capacitor (PSC), automatic thermal overload protection system, lower amp draw and sealed ball bearings.
description 1/6, 1/7 HP, 115V, 48M, 3450 rpm 1/4 HP, 115V, 48M, 3430 rpm
B206, B207, B208
Direct Drive Fan and Blower Motors
PSC Oil Burner Motors
mfr# 98022S 98630S
Features: • Split phase or capacitor start designs. • Drip proof. • Sleeve bearing. • Resilient base. • Automatic reset thermal protection. • Electronically reversible. • NEMA mounting dimensions.
• Resilient ring mount. • Automatic reset. • Fits Taco hot water circulators. • CCW fixed rotation (viewed opposite shaft end).
motors / accessories
mfr# 21805U 21444U
Features: • Split phase. • Single phase. • Dripproof. • Sleeve bearing.
Belted Fan and Blower Motors
Split Phase, NEMA Service Factor
Volts
1/7
Circulator Motors & Accessories
41/4 43/4
10.0 51/2 15.0 53/4
mfr# description webb# B & G Couplings H24-40W 1/12 – 1/6 HP Spiral 118705 69681 H24-10W 1/12 – 1/6 HP Zinc Spring 118705 28553 H24-60W 1/4 – 1/3 HP Cast Iron Spring 118723 69659 H24-15W 1/12 – 1/6 HP Cast Iron 118705 259933 H24-62W 1/2 – 3/4 HP Cast Iron 118473 259934 186410 1 HP Cast Iron Spring 53639
H24-10W
45612 1/2 X 4
45613 45614 91941
2761 H24-60W
84 7_Motors_Access_p88.indd 84-85
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
85 3/23/08 9:05:58 PM
Blower Parts
“Lau-Pak” – Sleeve Sealed Type with Insulator Self-aligning, factory packed with a supply of plastic petroleum assuring proper lubrication during long life of bearing. Self-aligning porous bronze sleeve pressed in housing.
38-2443-01 38-2443-02 38-2443-03
5/8”
1”
91943 91942 91944
Lau Oil Type – Sleeve Bearings with Insulator Self aligning, self-oiling, with bronze bushing held in housing under light, uniform spring pressure, which provides uniform distribution of lubricant through pores of bushing. Drive type oil cup. Temp. range mfr# DIA. mIN. MAX. od 38-2404-01 38-2442-01 38-2442-02
5/8” Lau 3/4” Lau
1” Lau
40°F 135°F 113/16” 40°F 135°F 113/16” 40°F 135°F 21/2”
webb# 91945 91946 91947
3/4”**
1”
40°F 40°F 40°F
135°F 113/16” 135°F 113/16” 135°F 113/16”
91954 91955 91956
5/8” 3/4”
1”
270-069-01 270-072-01 270-089-17 270-089-12 024768-10 024768-04
91957 91958 91959
5/8” 3/4”
1”
(Packaged 12 per bag) Resilient rubber pads that snap easily into place. Eliminates vibration, wear and noise on blowers, fans, motors, etc.
mfr#
Heavy neoprene cushioned. Reoilable porous bronze bushing in a pressed steel ball unit, firmly held in a housing of two-piece interlocking steel. Self-aligning static free and quiet operating. This high quality pillow block will assure many years of trouble-free performance.
38-2521-01
38-2204-01 38-2086-01 38-2087-01
5/8” 3/4”
1”
86 7_Motors_Access_p88.indd 86-87
40°F 40°F 40°F
135°F 135°F 135°F
webb# 91951 91952 91953
F.W. Webb Company
5/8” 1/2” 5/8” 5/8” 3/4”
91960
5/8” 3/4” 5/8” 3/4” 5/8” 3/4” 3/4” 1” 3/4”
5” 5” 6” 6” 7” 7” 8” 8” 6”
119014 91966 119015 91967 119016 111068 119009 119013 91967
Steel Steel Steel Steel Steel Steel Steel Steel Steel
For use where operating conditions exceed the limits of sleeve bearing or where repititive failures occur. These bearings are pre-lubricated at the factory and require no further lubrication or attention. They are equipped with seats for positive grease retention and protection against contaminants. mfr# Temp Range
dia. O.D. webb#
38-2588-01 38-2590-01
3/4”*
-20°F +250°F -20°F +250°F
1”*
113/16” 217/32”
119008 163604
* With interlocking thrust collar
Sleeve Bearing Bracket Kit Especially designed to fit most blowers from 9” to 16” sizes. This sturdy, compact, 10 gauge steel bearing and bracket is completely assembled ready to mount. The sintered bronze ball assembly is securely held in a spherical rubber isolating liner to assure maximum absorbtion of vibration, quiet operation, constant self-alignment and long life. Packaged in pairs with Shaft and Hardware Group. • Ideal for replacing. • obsolete pillow blocks. • Streamlined bearing may also be used in some evaporative cooler applications.
SHAFT MAX SHAFT mfr# dia. h.p. length 029175-01 3/4”
3/4 HP
20”
webb# 119010
Motor Adjustment Grommets Resilient rubber tips for use with tail-piece assembly to reduce motor vibration and noise.
webb# 91961
mfr#
Shafts Resilient rubber tips for use with tail-piece assembly to reduce motor vibration and noise.
webb# 91970
7
Packaged 6 per bag.
Motor Adjustment Kit
Oil Type – Sleeve Bearings with Insulator
Tail-piece for proper belt tension adjustment. 38-2523-01
91966 91967 91968 91969 119314 185821
31/4” Cast Iron 31/4” Cast Iron 4” Cast Iron 4” Cast Iron 31/4” Die Cast 4” Die Cast
mfr# Shaft Dia Material webb#
38-2525-01
mfr#
webb#
Whether steel, die cast, or cast iron all pulleys are tested for smooth, true running to insure quiet operation and long belt life. 38-2507-01 38-2213-01 38-2508-01 38-2214-01 38-2509-01 38-2215-01 38-2217-01 38-2218-01 38-2214-01
webb#
Motor attachment and adjustment hardware for 9”, 10”, 12”, and 15” blowers.
Pillow Black Sleeve Bearings
1/2”
O.D.
Blower Pulleys
Vibro Pads
Motor Mounting Hardware Kit 91948 91949 91950
(cont.)
Precision built for perfect balance, to assure smooth, quiet, vibrationless performance. Permits speed variation of approximately 30%. Grooves are accurately finished for proper belt seating, insuring maximum drive efficiency and long belt life. Finished for corrosion resistance and tested for true running.
(Packaged 12 per bag) mfr# DIA. webb#
Sealed Type Ball Bearings with Insulator
Variable Pitch Motor Pulleys
mfr# Shaft
38-2209-01
webb#
Conaire
Thrust Spacer Kit
* With Thrust Collar and Spacer ** With Journal
Temp. range mfr# DIA. mIN. MAX.
Blower Parts
motors / accessories
3/4”*
38-2431-01 38-2206-01 38-2207-01
mfr#
This cartridge type bearing has been designed to give you fast, easy interchangeability. It will fit any “spider type” bracket used on 9”, 10”, and 12” blowers.
38-2091-01 38-2272-01 38-2090-01
7
Sheet metal thrust collar in 3/4”, 5/8” and 1” size. All with hollow head (Allen) set screws. Kit consists of one pair packaged with thrust washers.
38-2491-01 38-2491-02 38-2491-03
Cartridge Type Sleeve Bearings
Temp. range mfr# DIA. mIN. MAX. od
7
mfr# DIA. webb#
webb#
40°F 135°F 113/16” 40°F 135°F 113/16” 40°F 135°F 21/2”
3/4”
SECTION
Thrust Collar Kit
Conaire
Temp. range mfr# DIA. mIN. MAX. od
SECTION
Self-aligning, self-oiling with sintered bronze bushings and drive type oil cups.
webb# 91962
www.fwwebb.com
mfr#
shaft dia. O.D.
38-2450-01 38-2449-01 38-2094-01
3/4”
1” 1” Heavy Duty
127/32” 127/32” 21/2”
The F.W. Webb Heating Catalog
mfr# DIA. Length 38-2205-01 38-2096-01 38-2095-01
5/8” 3/4”
1”
20” 20” 25”
webb# 91963 91964 91965
webb# 163602 119007 163599
F.W. Webb Company
87 3/23/08 9:06:12 PM
SECTION
7
V-Belts PurePro® V-Belts 4L V-Belts – 1/2” top width mfr#
description
webb#
mfr#
description
4L220W 4L230W
4L, 22”
100568
4L390W
4L, 39”
69710
4L, 23”
185481
4L400W
4L, 40”
69711
4L240W
4L, 24”
215878
4L410W
4L, 41”
69712
4L250W
4L, 25”
69696
4L420W
4L, 42”
69713
4L260W
4L, 26”
69697
4L430W
4L, 43”
69714
4L270W
4L, 27”
69698
4L440W
4L, 44”
69715
4L280W
4L, 28”
69699
4L450W
4L, 45”
69716
4L290W
4L, 29”
69700
4L460W
4L, 46”
69717
4L300W
4L, 30”
69701
4L470W
4L, 47”
69718
4L310W
4L, 31”
69702
4L480W
4L, 48”
69719
4L320W
4L, 32”
69703
4L490W
4L, 49”
69720
4L330W
4L, 33”
69704
4L500W
4L, 50”
69721
4L340W
4L, 34”
69705
4L510W
4L, 51”
104305
4L350W
4L, 35”
69706
4L520W
4L, 52”
104421
4L360W
4L, 36”
69707
4L530W
4L, 53”
185482
4L370W
4L, 37”
69708
4L540W
4L, 54”
104680
4L380W
4L, 38”
69709
4L550W
4L, 55”
104829
4L560W
4L, 56”
104969
4L570W
4L, 57”
105106
Note: Additional sizes in stock
webb#
Mars FHP B-Belts MARS FHP – 4L B-Belts mfr#
description
mfr#
description
94424
32” B
webb# 191186
94438
46” B
webb# 191204
94425
33” B
191187
94439
47” B
191205
94426
34” B
191188
94440
48” B
191206
94427
35” B
191189
94441
49” B
191207
94428
36” B
191190
94442
50” B
191208
94429
37” B
191191
94443
51” B
191209
94430
38” B
191192
94444
52” B
191210
94431
39” B
191193
94445
53” B
191211
94432
40” B
191194
94446
54” B
191212
94433
41” B
191195
94447
55” B
191213
94434
42” B
191196
94448
56” B
191214
94435
43” B
191201
94449
57” B
191215
94436
44” B
191202
94437
45” B
191203
Note: Additional sizes in stock
88 7_Motors_Access_p88.indd 88
F.W. Webb Company
www.fwwebb.com
3/23/08 9:06:13 PM
SECTION
8
Gas Burner G3B Power Gas Burner 60K - 180K BTU The G3B is a power gas burner for natural or propane gas—completely assembled, using premix combustion and hot surface ignition with lame rectification flame sensing. Features: • Converts from propane to natural gas with just an orifice change— no conversion kit needed. • Factory-packaged with combustion control and gas fuel train. • 60,000 to 180,000 Btuh—ideal for small to large homes. • Quiet and clean. • Dependable, hot surface ignition for quick, clean light-off. • Compact, efficient flame pattern. • Does not require a refractory liner—fires with or without a combustion chamber. • Ideal for high-efficiency wet-based boilers. • Superior for use in 2, 3, 4 or 5-section boilers. • Calibrated air throttle for easy adjustment. • Universal mounting flange. • Low-energy motor—only 0.40 amp • Includes 1-year warranty. mfr# 74245 74252
description G3B With 6” Tube G3B With 9” Tube
webb# 185221 95235
EZ-Gas Power Gas Burner 50K - 275K BTU
mfr# 9859210AFR1A 9859210BFR1
The F.W. Webb Heating Catalog
description webb# EZ-Gas 10” A 150K - 275K 379487 EZ-Gas 10” B 50K - 175K 379488
F.W. Webb Company
89
8 Gas heating
Features: • Converts from propane to natural gas with just an orifice change— no conversion kit needed. • Fires negative or positive chambers from 50,000 to 275,000 Btuh input. • Provides dependable, direct-spark ignition of main flame—for quick, clean light offs. • Comes standard with time-tested solid state ignition and state-of-the-art microprocessor control technology. • Factory-packaged with combustion control and gas fuel train. • Shipped completely assembled and wired—for “EZ” installation and start-up. • Diagnostic LED lights annunciated operating mode: Self-check, Flame-on, Recycle, Lockout and Latch-up. • High-efficiency, compact flame pattern design ensures clean, quiet operation. • Does not require a refractory liner—fires with or without a combustion chamber. • Available with custom welded air tube flange (and/or optional pedestal) to accommodate most appliance mounting requirements. • Includes 1-year warranty.
Ignition Modules
780-001
SECTION
8
8
Ignition Modules
Gas Ignition Controls
Replacement Controls and Components
Universal Ignition Controls
Ignition Control Units
Robertshaw’s Universal Ignition Control Uni-Kits feature a flame sense circuit that will work equally well on a one rod (local sense) or a two rod (remote sense) application. 780-001 (Nonlockout) The automatic recycle features assure that, in the event of flame failure, main gas is disabled and the spark repetition sequence is restarted until pilot gas is ignited. Only after pilot ignition has been re-established can main gas be returned to the burner. 780-002 (Lockout) These kits have a lockout feature to shut off all gas in the furnace, should pilot ignition fail to occur after a predetermined time period. The 780-002 provides 3 tries for ignition, each ignition period is 90 seconds followed by a 6 minute time delay between ignition attempts. After 3 tries if no pilot flame is sensed, unit goes into lockout and must be reset at the thermostat.
780-015 Add-on lockout module. Using the 780-015 module with 780-715 module will give application lockout timing function for use on LP gas, 60 second timing lockout on pilot and main gas flow. 780-735 Lockout Model. Flame rectification system. Use with gas valves 7000 BDER and 7100 DER. Has 60 second lockout timing. 780-845 Universal lockout model has three 90 second valve trials interrupted by a six minute purge cycle before 100% lockout.
mfr# 780-001 780-002
780-785
SECTION
description Non-Lockout Lockout
780-735
mfr# 780-015 780-735 780-845
webb# 118693 75124
description Non-Lockout Flame Rectification System Lockout Flame Rectification System Gas Ignition Control
webb# 105020 73462 167191
780 Series Hot Surface Ignition Module
Automatic Pilot Relight Kits
The 780 Series Hot Surface Ignition Modules are designed for use on gas fired heating systems The system acts on a demand for heat by a switch or thermostat to supply power to the ignition control. On non pre-purge models, the ignitor will be energized immediately and remain on for wither of two optional selected ignitor heat-up time approximately 17 or 34 seconds. For models with the prepurge option, there is a time delay equal to the heat-up time selected before the ignitor is energized.
The Robertshaw 785 Series automatic Pilot Relight Kits are designed for use on rooftop heating equipment, water heaters, boilers, space heaters, unit heaters, dryers, and other commercial, industrial, and residential appliances where the problem of pilot outage may occur. It should only be applied to those systems which already incorporate the necessary pilot-safety control system.
mfr# 780-785 780-787
description Gas Ignition Control Gas Ignition Control
785-001
webb# 167059 246666
mfr# 785-001
description Automatic Pilot Relight Kit
webb# 79497
Pilot Relite Control 780-910 Universal Hot Surface Ignition Module
Uni-Kit®
The relite control generates sparks until a pilot flame is sensed between the electrode and ground. When flame current is sensed between the electrode and pilot burner ground, the relite control stops sparking. If the flame is extinguished during the heat call, the relite control will begin sparking the instant the flame goes out.
780-910
mfr# 780-910
description Universal Hot Surface Ignition Module
webb# 155174
5059-23
The Hot Surface ignition Unit is a microprocessor based gas ignition control designed primarily for direct ignition and burner supervision applications such as gas furnaces, boilers, water heaters and other similar devices.
900-575 Module Tester The 900-575 Test Kit is designed specifically for the professional service technician. Now an electronic ignition module — intermittent pilot, direct spark, hot surface can be quickly and accurately diagnosed at the job site. The 900-575 Tester will diagnose all the circuit functions on an I.C.U. Checking for proper sequence of operation and/or failure. No more guessing which part to replace. With the 900-575 change out the defective part the first time, not on a return call back. 900-575
90
F.W. Webb Company
description webb# Spark Plug and 1/4” Spade Connectors 79497
Ignition Module for Hot Surface Ignition Systems
Test Equipment
mfr# description 900-575 Ignition Module Tester 720001W Quick Look Tester Q/L
ELECTRICAL mfr# INPUT VOLTAGE RATING 5059-23 24 Vac 0.03 Amps
webb# 152947 360275
MFR#
50E47-150
50E47-70
50E47 Prepurge time (in seconds)
4 Seconds
45 Seconds
0 Seconds
50E47-140 50E47-150 50E47-170
www.fwwebb.com
Lockout time
Ignitor warm-up time
The F.W. Webb Heating Catalog
17 Seconds 7 Seconds
45 Seconds
30 Seconds 0 Seconds
Webb# 83843 192971 85263 152586
F.W. Webb Company
91
8 Gas heating
The 780-910 Universal Hot Surface Ignition Module Uni-Kit is designed for use on gas fired systems. It is equipped with a self diagnostic green LED for quick troubleshooting. The LED indicates if the system is in normal operati on, has gone into lockout, has a weak flame signal, or has an internal error (a defective module).
Ignition Modules
SECTION
SECTION
8
8
Ignition Modules Spark Ignitor
Ignition Controls G600, G670
Q347
G600/G760 ignition controls are reliable, proven circuitry replacements for G60, G67 controls. In most cases the replacement controls have mounting configurations identical to the original device. Replacement controls feature precision timing for lockout models.
Produces spark for direct ignition of main burner. • Includes inner Kanthal electrode with ceramic insulator, bracket and Kanthol ground strap. • Use with S87C, D, K; S89E, F and Q354A.
Note: G600/G670 ignition control replacement parts must be used only for field replacement of existing equipment. These replacement parts must not be used for new field applications. MFR#
100% Lockout
G600AX-1C
remarks
Webb#
Yes
24 Vac, Terminal Bard Wiring
97579
No
24 Vac, 1/4” Spade Wiring Connections
192971
No
G670AW-1C
G600
damper plug
mfr# Rod Angle Q347A1004 Standard Orientation Q347
S8610U
The G779 Universal Replacement Intermittent Pilot ignition Control replaces many existing intermittent pilot controls made by various manufacturers. It is a safety control designed for indirect burner ignition and supervision. The G779 can be used with all gas-fired appliances with a maximum firing rate of 400,000 Btu/hr. G779
Applications The G779 replaces existing intermittent pilot ignition controls with the following specifications: • Flame detection using flame rectification technology (ability of a flame to conduct and rectify current). • Integral or remote flame sensing. • Non-100% lockout, 100% lockout, or 100% shutoff with continuous retry. • Trial for ignition period greater than or equal to 25 seconds. • Prepurge period less than 1 second. • Pilot burners with flow rates of 1,500 Btu-hr or less. • Operating with or without vent dampers.
Specifications Operating voltage Ignition source Prepurge Number of trials before 100% shutoff Trial time for ignition Retry delay period Flame failure response time Type of gas mfr# G779LHA-1C
92
24 Vac at 50/60 Hz High voltage spark, capactive discharge Less than one second One 25 Seconds 5 Minutes 0.8 Seconds Natural, Liquified Petroleum (LP), manufactured, mixed or LP gas-air mix
Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) Intermittent Pilot Ignition Modules. Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers, and other heating appliances. • Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances. • Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed. • For use in single rod of dual rod/remote sense applications. • Includes relay contacts for use with any intermittent pilot has control string with maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended. Ignition Lockout Ignition Trials mfr# Description trial time timing to lockout webb# S8610U3009 Intermittent Pilot Control Continuous Retry 90 Sec. Max. Continuous Retry 74468
Universal Hot Surface Ignition Module S8910U Provides operating control of a direct ignition system using a 120 Vac hot surface ignitor. • Provides easy field-replacement of a wide range of hot surface ignition modules manufactured by Honeywell, Robertshaw, and White-Rodgers. Refer to the product specifications sheet for specific models that can be replaced by the S8910U. • For 120 Vac (up to 5.0A) hot surface igniter (Norton 201/271 or equivalent). S8910U
8
The S8910U can be used only for direct replacement of specific installed models. Check the product specification sheet before replacing an existing hot surface module with the S8910U. If the existing module is not listed, do not use the S8910U to replace it. Always use the selection tab specified in the product specification sheet for the existing module being replaced. Replacement of an unlisted module or use of a selection tab other than specified can result in appliance malfunction. Ignition Lockout Ignition Trials mfr# Description trial time timing to lockout webb# S8610U1000 Hot Surface Ignition Control 4 Sec. or 7 Sec. 4 Sec. or 7 Sec. 1 or 3 92054
description webb# Universal Intermittent Pilot Ignition Control 110805
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
93
Gas heating
The G779 is not designed to replace ignition controls with the following specifications: • Pilot flame detection by any means other than flame rectification. • Trial for ignition period of less than 25 seconds. • Prepurge period greater than or equal to 1 second. • Standing pilot applications.
Universal Intermittent Pilot Module S8610U
Universal Replacement Intermittent Pilot Ignition Control G779
webb# 188466
Ignition Modules
SECTION
SECTION
8
8
Gas Valves
Gas Ignition Modules
Water Heating
S89C Hot Surface Ignition Module
Domestic, Commercial & Recreational Vehicle Water Heater Thermostat Uni-Kits® 110 Series The 110-Series Water Heater Thermostat Uni-Kit® and Commercial Water Heater Thermostat Uni-Kit were designed for universal replacement applications. All models feature built-in, noncycling Energy Cut-Off (ECO) system to shut off all gas to the water heater in case of excessive water temperatures. All models have a 51/2” sensing element and vary by inlet and outlet size, shank length, regulator type and setting.
Provide electronic control of 120V hot surface ignition systems used in furnaces, boilers and other heating appliances. • S89C is for systems with combination ignitor-sensor. • Use with Norton 201 Hot Surface Ignitors or equivalent. • Lockout after one trial for igniting if main burner fails to ignite. • Reset from thermostat after lockout. mfr# S89C1087 S89C1095
S89C
Lockout timing 6 Sec. 15 Sec.
ignition Trial TIme 6 Sec. 15 Sec.
webb# 95080 152200
MFR#
110-202
Ignition sequence
typical gas control
Gas type
Webb#
Continuous Retry (after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place)
VR8304M Dual Valve Combination Gas Control
LP/Natural
74467
S9200U1000
–40° F to +175° F
30 seconds
HSI HEAT HEAT WARMUP POST- ON FAN OFF FAN TIME PURGE DELAY DELAY 17/27 or 30/30 seconds
15 seconds
30 or 60 seconds
60, 90, 120, or 180 seconds
85376
23/8”
3.5” W.C. Natural Gas
246749
13/8”
3.5” W.C. Natural Gas
73452
Domestic and Commercial LP Gas Water Heater Thermostat Uni-Kits®
Temp. Setting
110-262
160º
110-265
160º
110-285
180º
Shank Length
PresSure regulator setting
Webb#
1/2” Inverted
1/2” Pipe
Flare
Preset @ 10.0 (Adjustable from 9” W.C. - 12” W.C.)
13/8”
73449
COOL FAN ON DELAY
5 seconds
1/2” Pipe
1/2” Inverted Flare (Left hand Threads)
13/8”
Preset @ 10.0 (Adjustable from 9” W.C. - 12” W.C.)
11/2”
73450 75123
700 (70000GO) Commercial 700-800 Series bleed gas diaphragm valves feature: automatic pilot valve, bleed gas operator, inlet and outlet screens, manual “gas cock” valve, pilot adjusting key, pilot gas filter and pressure regulator (optional by model). Pressure Regulator Factory set at 3.5” W.C. MFR#
INLET size (FPT)
Outlet SizE (FPT)
PresSure regulator setting
Reducer bushings included (NPT) Capacity 3/4” x 1/2”
Webb#
700 “Thermopile” Type Diaphragm Gas Valves 700-885
3/4”
3/4”
None
305,000
2
186756
Gas Water Heater Controls
COOL FAN OFF DELAY
GAS CONTROL USED WITH
Webb#
0 or 60 seconds
Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
372843
For replacement of standard gas water heater controls with built-in E.C.O. (energy cut-off ). Features • Automatic shut-off of amin and pilot gas in the event of pilot failure. • Pilot gas cock with safe lighting feature. • Pilot gas filter. Specifications Inlet Size: 1/2” NPT Outlet Size: 1/2” Inverted Flare Mounting: 3/4” NPT, 11/4”, shank length, 41/2” bulb insertion length Pilot Connection: 1/2” compression fitting 37C63U-114 MFR# 37C63U-114
F.W. Webb Company
Outlet Size
Left Hand Thread — Outlet: Replaces Model R65RR
F.W. Webb is a master distributor of the full line of rego products! 94
INLET size
Right Hand Thread — Outlet: Replaces Model RPL
Controls a standard induction-type circulating fan motor. • Main burner ignition using a 120V hot surface igniter. • Flame rectification circuit to monitor flame presence. • Monitoring of system pressure switch, high temperature limit, and rollout functions. • Appliance operation/safety requirements controlled via microprocessor. • Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM™ thermostat. • LED system status, performance and diagnostic indication. • Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances. • Twinning capability • EnviraCOM™ communication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control. PREPURGE
4.0” W.C. Natural Gas
1/2” Inverted Flare
www.fwwebb.com
The F.W. Webb Heating Catalog
main burner
pilot
Temp. Range
shank length
Webb#
3.5” W.C.
Adjustable
70° F – 160º F
11/4”
188187
F.W. Webb Company
95
8 Gas heating
MFR#
AMBIENT TEMP. (F)
13/8” 1/2” Pipe
Webb#
The 110 Series Water Heater Uni-Kits® are designed for universal replacement applications. All models feature built-in, non-cycling Energy Cut-Off (ECO) system to shut off all gas to the water heater in case of excessive water temperatures. All models have a 51/2” sensing element and vary by shank length.
S9200U1000 Universal Hot Surface Ignition Integrated Furnace Control
S9200U1000
PresSure regulator setting
110-326
MFR#
Y8610U3003
shank length
110-202
Complete kits converting conventional standing pilot system to intermittent pilot system. For use with 24 Vac gas-fired atmospheric furnaces, boiler and heating appliances. • Y8610U kits are for use with natural of LP gas; provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. • Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed. Y8610U
Outlet size
110-206
Y8610U Universal Retrofit Intermittent Pilot Gas Burner ignition Systems
MFR#
Inlet Size
SECTION
SECTION
8
8
Gas Valves
Gas Valves
Gas Oven Safeties
Gas Valves
1720 (TS) “J” and “K” Magnet Heads
Pilot, Direct and Hot Surface Ignition 700 Series
The 1720 Series Replacement Magnet Kit is used with 1710 Series Bodies in TS Automatic Safety Valve applications. All models have FLOW INTERRUPTION so that no gas can flow to the main burner while the reset button is depressed. 1720 Series Kits are designed to replace many individual TS magnet types. Each magnet head kit is tapped for 1/8” pipe with fittings to adapt to 3/16” and 1/4” compression tubing. Also included: spring and diaphragm components, gasket and assembly screws. 1720-801
mfr# 1720-801 1720-802
description Pilot Size Gas Oven Safety With Tubing Kit – “J” Head 1/8” Pipe, 3/16” Tubing, 1/4” Tubing Gas Oven Safety With Tubing Kit – “K” Head 1/8” Pipe, 3/16” Tubing, 1/4” Tubing
These 700 Series Gas Valve Uni-Kits® are designed for intermittent pilot, direct spark and hot surface applications. They incorporate a manual valve, pilot valve, and main gas pressure regulator. Each Uni-Kit includes all the necessary parts and instructions needed to convert to direct spark or hot surface applications.
webb# 75107 85431
MFR#
The 4020 Safety Pilot Valves provide gas shutoff in case of pilot outage. When the reset button is depressed, gas will flow to the pilot only. Main gas will not flow until the pilot is operating and the reset button has been released. Pilot inlet and outlet connections are 1/2”tubing, unless otherwise indicated. 100,000 BTU/HR capacity. Ambient Temperature 32° – 350°F. 4020-010
main burner
4020-010
48”
4020-011
54”
pilot
Temp. Range
Webb#
11/64”
186656
15/64”
75110
1/2” Pipe
The 4030 Series is the same as the 4020 Series except they have a pilot outlet only. Pilot gas is supplied through a drilled passageway to the pilot valve chamber and outlet. Pilot outlet is ¼” tubing. MFR#
Capillary Length
inlet/outlet size
4030-001
reset button length
1/2” Pipe
4030-002
48”
3/8” Pipe
4030-003 4030-005
54”
73475
11/64”
189056
700-506
3/4”
3/8”
3.5” Nat. Gas
350,000
85381
700-059
1”
1”
4.0” Nat. Gas
720,000
167052
stand-by pilot outlet
Inlet size
inlet adapter fittings included
Webb#
12”
1
1/8” Tubing
7/16” Tubing
3/8” Tubing & 1/2” Pipe
94210
The 4060-700 (MSC) Series has a thin flexible capillary and is used with a 4700 (U) or 4750 (ELO) Series Thermostat. Any excess capillary on a replacement valve may be coiled out of the way as required (caution should be taken to avoid crimping) and will not affect the valve operation.
96
12”
4060-702
21”
4060-703
12”
F.W. Webb Company
3/4”
capacity
1/2”
X
X
1/2”
3/8”
Webb#
1/2”
1/2”
1/2”
None
100,000
2
192864
700-502
1/2”
1/2”
1/2”
3.5” W.C. Nat. Gas
100,000
2
186752
700-503
1/2”
3/4”
1/2”
None
240,000
1
94207
700-505
3/4”
3/4”
Straight-Thru
None
300,000
2
73457
700-506
3/4”
3/4”
Straight-Thru 3.5” W.C. Nat. Gas
300,000
2
73458
700-507
1/2”
3/4”
Straight-Thru 3.5” W.C. Nat. Gas
240,000
1
192865
700-511
3/4”
3/4”
Straight-Thru 3.5” W.C. Nat. Gas
300,000
2
193214
The 700-200 Series snap-action and snap-throttle (modulating) hydraulic controls are combination gas valves, thermostatically operated by a remote temperature sensing bulb. These controls combine a manual valve (gas cock), an automatic pilot safety valve, pressure regulator (optional by model) and a snap-acting or snap-throttle hydraulic operator for total temperature control. All models feature 3-position main gas outlets and pilot outlet, pilot gas filter, pilot adjustment key and automatic pilot valve.
inlet size 7/16” Tubing 3/8” Tubing
MFR#
Webb#
3/8” Tubing
73477 94209 111051
www.fwwebb.com
capacity
Reducer bushings included (NPT) 1/2” X 3/8”
Webb#
100,000
2
73454
Snap Action Models 700-201
inlet adapter fittings included
3/8” Tubing
700-201
internal Inlet 3 Position pressure size outlet capillary regulator (FPT) (FPT) length setting 1/2”
1/2”
36”
None Snap Throttle Models
700-204 700-205
The F.W. Webb Heating Catalog
1/2” 1/2”
1/2” 1/2”
36”
None
160,000
2
73455
36”
3.5” W.C. Nat. Gas
100,000
2
85383
F.W. Webb Company
97
8 Gas heating
Bushing type
4060-701
pressure regulator setting
700 Snap-Action and Snap-Throttle Hydraulic
Capillary Length
Capillary Length
side (FPT) w/ plugs
700-501
4060-700 (MSC) Safety Valve
MFR#
Inlet Straight size Through (FPT) (FPT)
73476
The 4060 (MSA) Series safety valve has a heavy capillary.
4060-001
Webb#
Pool Heater Models
4060 (MSA) Safety Valve
MFR#
capacity
The 700 millivolt gas valves are wall thermostat actuated combination gas valves. These controls combine a manual gas cock, automatic pilot safety valve and a millivolt operator. The automatic pilot safety is separate from the gas cock and provides gas shutoff in case of pilot outage. Standard features include: pilot outlet, pilot gas filter and pilot adjusting key. Valves can be mounted in any position except upside down.
167050
15/64”
1/2” Pipe
pressure regulator setting
700 Millivolt
Webb#
43/64”
straight through
700-056
MFR#
4030 (FMEA) with Pilot Outlet Only
OUTLET SIZE (FPT)
Universal Models Intermittent Pilot, Direct Spark & Hot Surface
4020 (FMDA) with Pilot Inlet and Outlet
MFR#
Inlet size (FPT)
SECTION
SECTION
8
8
Gas Valves
Gas Valves
Gas Valves (cont.)
Gas Valves (cont.)
700 24 Volt Combination Valve
710 Low Profile Gas Heating Valves
These valves feature a manual valve (gas cock), an automatic pilot safety valve, inlet/outlet screens, pilot outlet, pilot gas filter and pilot adjustment key. The automatic pilot safety valve is separate from the gas cock and provides gas shutoff in case of pilot outage. Valves can be mounted in any position except upside down.
The 710 low capacity gas heating valves are designed for recreational vehicles and other applications with limited space. All models include a manual valve (gas cock), automatic pilot safety valve, pilot outlet, pilot gas filter and pilot adjusting key. The control can be mounted in any position except upside down and all models have 3-position outlets.
MFR# 700-400 700-401 700-402 700-406 700-426 700-438 700-442
3 position outlet Inlet straight side (FPT) Pressure size thru with regulator (FPT) (FPT) plugs setting Snap Action Models 1/2” 3/4” Straight-Thru Uni-Kit 1/2” 3/4” 1/2” None 1/2” 3/4” 1/2” Uni-Kit 3/4” 3/4” 3/4” 3/4” Straight-Thru 3.5” S.W. 1” 1” Nat. Gas 1” 1”
capacity 240,000 240,000 240,000 300,000 300,000 720,000 720,000
Reducer bushings included (NPT) 3/4” X 1/2” 1 1 1 2 2
MFR# Webb# 186748 79496 192862 73456 204405 215820 103214
710-201 710-203
710-203
710-205 710-402 710-501
700-406
700 Diaphragm/Solenoid Valves
MFR#
Pressure regulator setting
capacity
Reducer bushings included (NPT) 3/4” X 1/2”
Webb#
1/2” 1/2” 3/4”
3/4” 3/4” 3/4”
Straight-Thru 1/2” Straight-Thru
None 3.5” W.C. Nat. Gas
300,000 240,000 300,000
2 1 2
118694 204528 167053
MFR#
720-079
720-051 720-079
700 Line Voltage
MFR#
Inlet straight size thru (FPT) (FPT)
700-451
1/2”
3/4”
700-454
3/4”
3/4”
side (FPT) Pressure with regulator plugs setting 120 Volt Models 1/2” None 3.5” W.C. Nat. Straight-Thru Gas
Webb#
240,000
1
186750
300,000
2
75115
705 Millivolt Operators The 705 Series millivolt operator kit is designed to allow field conversion of 700 & 710 Series manual gas valves to wall thermostat control. These operators are also replacements for specific 700-500 Series gas valves. MFR# 4020-010
98
block color 48”
F.W. Webb Company
pressure sensitive setting None
186765 94208
side outlet pressure ½” fpt with regulator plugs setting capacity Standard Model 1/2” 3/4” Uni Kit 150,000 • Universal Model — Intermittent Pilot — Direct Spark — Hot Surface 1/2” 3/4” Uni Kit 150,000
InleT size (FPT)
outlet size
Webb# 75113 90878
8
The 720 Series Dual Valve Gas Controls are designed for a wide variety of heating applications and can be used to replace most constant pilot valves, including dual valve (six function) models. The 720 Series constant pilot gas valve is a six function valve incorporating the manual valve, safety shutoff magnet, dual automatic valves (hence the term dual valves”), main gas regulator, and pilot adjustment. 720-406
MFR# 720-400 720-401 720-402 720-403 720-406 720-474
Inlet size (FPT) 1/2”
1/2” 1/2”
OUTlet size (FPT)
SIDE OUTLET pressure REDUCER BUSHINGS STRAIGHT 1/2” FPT regulator THRU WITH PLUGS setting CAPACITY 3/4” X 1/2” 1/2” X 3/8” • Uni IG 1 • • None 150,000 1 • • 1 3/4” • • 1 Uni IG • 150,000 2 Standing Pilot Models — Stop Opening with Convertible Pressure Regulator 1/2” • • • 150,000 1
Webb# 17056 73460 167057 186770 73461 186771
Webb# 192867
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
99
Gas heating
capacity
Reducer bushings included (NPT) 3/4” X 1/2”
186764
720 Series Dual Valve Gas Controls
These controls combine into one compact valve: a manual gas cock, automatic pilot safety valve and a silent line voltage operator. The automatic pilot valve is separate from the gas cock and provides gas shutoff in case of pilot outage. Valves can be mounted in any position except upside down. 3 position outlet
73459 85422
The 720 Electronic Ignition Gas Valves are designed for a wide variety of heating applications. The valves incorporate a manual valve, dual automatic valves and a main gas regulator. Controls are multiposition and can be mounted in any position (except upside down).
24 Volt Diaphragm Models – Have No Safety Magnet 700-417 700-422 700-454
Webb#
720 Series Hot Surface Gas Valves
These controls are single function, diaphragm types and are excellent replacements for solenoid gas valves. Standard features include: pilot outlet, pilot gas filter and pilot adjustment key. Valves can be mounted in any position except upside down. 3 position outlet Inlet straight side (FPT) size thru with (FPT) (FPT) plugs
Inlet reducer pressure size 3 position bushings cap. regulator (FPT) outlet incl. (fpt) length setting Application Hydraulic Models — Snap Action 18” Recreational None Vehicles 1/2” 1/2” (2) 1/2” X 3/8” 36” 3.5” W.C. Wall Furnaces Nat. Gas Replaces TV-27 24 Volt Models 3.5” W.C. Wall Furnaces 1/2” 1/2” (2) 1/2” X 3/8” N/A Nat. Gas 12 VDC, 24 VAC Millivolt Models Note: Use two lead thermopliles only. Space Heaters 1/2” 1/2” (2) 1/2” X 3/8” N/A None Replaced B-67
SECTION
SECTION
8
8
Gas Valves
Gas Valves
Commercial Gas Thermostats
SmartValve™ System
4200 (FD) Body Type #2 and Body Type #3 MFR# 4200-005
InleT INLET/ size OUTLET (FPT) SIZE #2 1/2” Pipe
PILOT Side
SV9501
CAPILLARY MOUNTING LENGTH POSITION 48” 4-Way
BULB SIZE 3/16” X 143/4” Nickel
Combines gas flow control and electronic intermittent pilot sequencing functions into a single unit. • Suitable for a wide range of gas-fired appliances including residual furnaces, roof-top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking units • Replaces SV9500, SV9501 and SV9502 control. See installation instructions for specific models. Ignition sequence includes timed trial for ignition
Webb# 186685
4200 (FD) Body Type #1 MFR# 4200-025 Uni-IGI
BODY TYPE #2
INLET INLET OUTLET OUTLET SIDE REAR SIDE SIDE PILOT CAPILLARY MOUNTING “f” “H” “E” “G” OUTLET LENGTH POSITION 150° to 550° F (Degrees) 3/8”
3/8”
Pipe
3/8”
Pipe
4200
Pipe
3/8”
Pipe
Side & Rear
54”
4-Way
3/16” X 141/4”
#2
3/8”
3/8”
Pipe
Pipe
3/8”
Pipe
3/8”
Pipe
Side & Rear
4-Way
3/16” x 141/4”
54”
Webb#
SV9501 MFR# SV9501M2528 SV9502H2522
75113
Nickel
Low (200° F) to 550° F (Degrees) 4200-025 Uni-IGI
BULB SIZE
Q3400A1024
90878
Nickel
GAS IGNITION VALVE UNIT DESCRIPTION Nonlockout Models — Caution: Do not use on LP. Gas Applications 780-715 Natural Gas Only — Nonlockout Pressure regulator is 700-055 3/4” X 3/4” (Nonlockout) factory-set at 3.5” W.C. 350,000 Btu Max
V800 MFR#
Webb#
V800A1070 75113
V800A1088
Packages Available FLAME SENSOR 3098-134
ELECTRODE ASSEMBLY 760-56
PILOT RELIGHT 5059-23
WIRING HARNESS F115-0084
Specifications MFR# 21D18-3
COIL VOLTAGE 60 Hz 24 Vac
F.W. Webb Company
INLET/ OUTLET SIZE 3/4” X 3/4”
3.5” W.C.
1/2” X 3/4”
INCLUDES One 3/4” X 1/2” Reducer Bushings/Adapters Two 3/4” X 1/2”, One 1/2” X 3/8” Reducer Bushings/Adapters
Webb# 35054 35055
ELECTRICAL RATING 0.61 amps
INLET/ OUTLET SIZE 3/4” X 3/4”
CAPACITY A.G.A. STANDARD GAS 280,000
VR8200
Combination gas controls for use in 24 Vac. gas-fired, standing pilot appliances with capacities from 20 to 200 cfh. • Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment. • Compact size. • Provide two automatic valves. • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. LITE-RITE (OFF-PILOT-ON) lighting sequence. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure. • Compatible with ECO connector. MFR#
GAS TYPE Natural Only
TYPE OF GAS
PRESSURE INLET/ REGULATOR OUTLET SETTING SIZE
OPENING CHARACTERISTICS
www.fwwebb.com
INCLUDES
Webb#
1/2” X 3/8” Reducer
Webb# 188185 VR8200A2132
100
Natural Or LP
PRESSURE REGULATOR SETTING
The F.W. Webb Heating Catalog
Natural
3.5” W.C.
1/2” X 1/2”
Standard
Bushings; 38389014 bag assembly- 3/4” straight flange with O ring screws and wrench; and 393891 Natural to LP Gas Conversion Kit
F.W. Webb Company
68550
101
8 Gas heating
Control system designed to eliminate standing pilots by converting to cycle–pilot controls with automatic spark ignition. Gas valve functions are terminated on a printed circuit board that exits through the mercury flame sensor receptacle housing, on the terminal panel side. Features • Eliminates gas wasted by a standing pilot. • Eliminates pilot outage problems due to occasional drafts. • Each package contains the controls and hardware needed for conversion to cycling pilot operation. • Uses existing pilot burner and wiring. GAS VALVES 38C84-426
TYPE OF GAS
VR8200 Continuous Pilot Dual Automatic Valve Combination Gas Controls
Cycle-Pilot® Retrofit Kit
MFR# 21D18-3
154343
Ignitors
Provide complete control of continuous pilot gas-fired central furnaces and boilers. • Include pilot flow adjustment screw. • Complete safety shutoff on pilot flame failure. • LITE-RITE (OFF-PILOT-ON) lighting sequence.
The Uni-Line 712 series pilot ignition system features flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. The 712 series pilot ignition system features quick and easy installation with complete in-depth instructions and trouble shooting information.
21D18-3
Webb# 210227 214000
V800 Low Voltage Combination Gas Controls
®
712-016
OPENING CHARACTERISTICS Standard Opening Slow Opening
Gas Valves,Electronic Single Stage — Standing Pilot
712 Series Intermittent Pilot Ignition Uni-Kits
MFR#
PrePurge None 15 Sec.
Ignitor For SmartValve
Kits
Uni-Kit
PRESSURE REGULATOR SETTING 3.5” W.C. 3.2” W.C.
TEMPERATURE RATINGS -40° F To 175° F -40° F To 175° F
Gas Valves
VR8300
SECTION
SECTION
8
8
Gas Valves, Electronic Single Stage — Standing Pilot
Gas Valves, Electronic Single Stage— Direct Ignition
VR8300 Continuous Pilot Dual Automatic Valve Combination Gas Control
VR8345 Universal Electronic Ignition Combination Gas Control
Combination gas control for use in 24 Vac. gas-fired standing pilot appliances with capacities from 30 to 300 cfh. • Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment. • Compact size. • Provide two automatic valves. • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure. • Compatible with ECO connector. • LITE-RITE (OFF-PILOT-ON) lighting sequence.
Universal electronic ignition combination gas control for use with direct spark ignition, hot surface ignition or intermittent pilot ignition in 24 Vac, gas-fired appliances, with capacities from 30 to 415 cfh. • Control includes manual valve, two automatic operators, pressure regular, pilot adjustment, pilot plug and ignition adapter. • Replaces virtually any IP, HSI, or DSI gas control • For use with natural or manufactured gas or LP gas. Includes converter kit to adapt from natural to LP gas. • Compact size. • All adjustments and wiring connections accessible from top of control. • Four-inch swing radius allows easy rotation into position inside the tightest furnace vestibules. • Clearly marked, keyed terminal block allows quick attachment of wires and IP/DSI/ HSI jumper. • Internal inlet screen blocks contaminants in gas line from entering valve.
MFR# VR8-300A4516
PRESSURE INLET/ REGULATOR OUTLET SETTING SIZE 3.5” w.c.
3/4” X 3/4”
INCLUDES Two 3/4” X 1/2” Reducer Bushings; 383200EOO adapter, Q340 (36”) thermocouple with adapters, 393691 Natural to LP Gas Conversion Kit
VR8204A2076
-18° F to +79° F
F.W. Webb Company
3.5” w.c.
1/2” X 1/2”
Standard
TYPE OF GAS
VR8345M4302
3/4” X 3/4”
3.5” w.c.
Natural
INCLUDES Two 3/4” X 1/2” NPT Reducer Bushings and one 1/2” X 3/4” NPT Bushing
Webb# 93587
Provide complete control of continuous pilot gas-fired central furnaces and boilers. • Include pilot flow adjustment screw. • Easy to install, adjust and service; all adjustments and connections are accessible from top of control. • Add separate energy cutoff (ECO) where codes call for dual safety shutoff. • Complete safety shutoff on pilot flame failure. • LITE-RITE (OFF-PILOT-ON) lighting sequence. • ECO connector for V800 models. Part No. 392451-1.
VS830
MFR#
INLET/OUTLET SIZE
VR820A1047
!/2” X 3/4”
VR820A1054
3/4” X 3/4”
PRESSURE REGULATOR SETTING
TYPE OF GAS
3.5” w.c.
Natural
Webb# 35056 35057
WAGS Water and Gas Safety Valve The WAGS Water and Gas Safety Valve™. The WAGS valve shuts off the water supply (plus has supply for gas-fired water heaters) when it detects a water leak, preventing disastrous flooding and damage to structures and belongings. WAGS
mfr# WAGS7200
size & Connection Water and Gas Safety Shut-Off Valve for Hot Water Heaters
webb# 243562
FloodMaster, inc. Water Feed
Alarm/Shut-off System Kit
INCLUDES 3/4” X 3/8” Reducer Bushing 393691 Natural to LP Gas Conversion Kit
Webb# 76221
www.fwwebb.com
• • • • • •
Easy installation. mfr# description No wiring — just plug in. FLOODMASTER Alarm/Shut-Off Kit No maintenance. Audible alarm and interface with your home security system. NSF 61/UL/CE/CSA. Reusable.
The F.W. Webb Heating Catalog
F.W. Webb Company
webb# 242185
103
8 Gas heating
MFR#
PRESSURE REGULATOR SETTING
VS830 Millivoltage Combination Gas Controls
Combination gas control for use in 24 Vac. gas-fired intermitent pilot appliances with capacities from 20 to 200 cfh. • Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment. • Use with S86F,H; S8600F,H and S8610 Control Modules. • Compact size. • Provide two automatic valves. • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • ON-OFF lighting sequence. VR8204
MFR#
INLET/ OUTLET SIZE
Gas Valves, Millivolt
86743
VR8204 Intermittent Pikot Dual Automatic Valve Combination Gas Controls
PRESSURE INLET/ OPENING TEMPERATURE REGULATOR OUTLET CHARACTERRATINGS SETTING SIZE ISTICS
VR8345
Webb#
Gas Valves, Electronic Single Stage — Intermittent Pilot
102
Gas Valves
SECTION
SECTION
8
8
Thermocouples & Thermopile Generators Thermocouples and Pilots 1950 & 1951 Thermopiles The 1950 and 1951 Thermopiles (pilot generators) are designed for use on self-positioned gas control systems.
Mfr# 1950-001 1950-002 1950-003 1950-532 1950-548 1951-001 1951-536
Includes PG9 Connection Length Pilot Adapter Webb# Type 82642 36” • 194065 48” • Two Lead 186640 60” • 192848 36” 186641 48” 73469 36” • Coaxial 111602 36”
1970 Uni-Couples 20 to 30 Millivolts The 1970 Series Uni-Couples unique design allows for installation to virtually all pilot burners. The versatile zip nut may be pushed, pulled or threaded onto the thermocouple’s rolled threads for proper positioning in every application. The stainless steel tip (longer life), extended cold junction (greater voltage output potential), copper tube (corrosion protection with low electrical resistance), and lock washer equipped coaxial connection (resists loosening due to vibration or changes in ambient temperature) make the Uni-Couple the single most versatile thermocouple available today. LENGTH 18” 24” 30” 36” 48” 60” 72”
webb# 167188 167189 167190 85375 155170 186644 85441
The 1960-027 is a special low-mass or quick dropout thermocouple. It is usually found on applications that require an oxygen depletion system on the thermo safety. Also found on many L.P. gas applications that require a quick dropout of the thermo safety if there is a loss of pilot flame. Note: Has standard thermocouple threads. Will not fit applications with metric threads. mfr# 1960-027
LENGTH 27”
webb# 217093
Replacement Parts Thermocouple Test Adapter Adapter to test thermocouple and thermopile closed circuit. mfr# Description 10-238 Thermocouple Test Adapter
104
webb# 73470 73471 186645 73472 152596 73473 188181
F.W. Webb Company
Mfr#
Length (IN)
K15DS-18H K15DS-24H K15DS-30H K15DS-36H K15FS-24H K15FS-36H K15WS-48H
18 24 30 36 24 36 48
TYPE
Standard BASO
Snap in BASO Standard BASO w/ Fittings
Webb# 184577 183556 183557 184579 183561 183562 183563
Increases length of 11/4” and 13/8” shank models to approximately 3”. webb# 80696
Junction Block Adapter The 1922-001 adapter allows the high limit switch to be connected into the thermocouple cicuit on valves without the sloted magnet. mfr# Description 1922-001 Junction Box Adapter Junction Block Adapter Y99AN-1H
webb# 75109 178174
The 1980 Series Snap-Fit Thermocouples offer easy installation into the majority of pilot burners. Both slim and standard thermocouple types are available in the 1980 Series without complicated adapters, but with the extra insulation from high ambient temperatures that the brass sheath offers when needed. The 1980 is constructed of the same materials as used in the 1970. LENGTH 18” 24” 30” 36” 48” 60” 72”
The K15 Series Thermocouples are designed for use in standing pilot ignition systems. They are used primarily with BASO brand automatic pilot controls and pilot burners. K15DS models are standard thermocouples. K15FS models are snap-on thermocouples that allow for fast, easy assembly. The K15WS model is a wholesale thermocouple that is supplied with additional fittings.
webb# 167043
1980 Snap-Fit Thermocouples
mfr# 1980-018 1980-024 1880-030 1980-036 1980-048 1980-060 1980-072
K15 Series
Shank Extension
mfr# Description 10-250 Shank Extension
F.W. Webb stocks gas stoves and fireplaces! www.fwwebb.com
“Super Slim Jim™” Universal Replacement Thermocouples
Standard BASO® Thermocouple
“Husky” High Performance Thermocouple
Mfr#
Length (IN)
K19AT-18H K19AT-24H K19AT-30H K19AT-36H K19AT-48H K19AT-60H
18 24 30 36 48 60
TYPE
Webb#
“Super Slim Jim”
183569 183570 183571 152513 155142 183574
Replacement Thermopile Generators Q313
Provide power for millivoltage, self-powered control systems. • Eliminate the need for outside power source. • Easy push-in installation. • Include spade terminals. • Individually skin packed, each unit ordered represents one thermopile generator. Lead Length Resistance
Mfr# Q313A1055
47”
2.90 ohm
includes
Webb#
1/2” thermopile
188174
attaching nut
K16 Series
Q313A1139
Push-in clip
83335
The K16 Series are heavy-duty, high performance thermocouples that provide high output for residential, commercial, and industrial applications. The “Husky” is a replacement for BASO 17D, 50, 58D, 87D, 88D, 97D, 107D, and K15DA thermocouples. The K16 is packed with adapters to allow the necessary replacement. K16BT models are standard thermocouples. K16RA models are nickel plated thermocouples. K16WT models are wholesale thermocouples that are supplied with additional fittings.
Q313A1170
PG9 adapter (part #393948)
85874
Q313A1188
1/2” thermopile
Mfr#
Length (IN)
K16BT-18H K16BT-24H K16BT-30H K16BT-36H K16RA-60C K16WT-48H
18 24 30 36 60 48
TYPE “Husky”
“Husky” Nickel Plated “Husky” with Fittings
The F.W. Webb Heating Catalog
Webb# 183564 152511 183565 96960 194088 183568
35”
2.89 ohm
Push-in clip,
attaching nut Includes junction box for series hook up with high limit switch
Q313A1005
84659
86741
Universal 30 mV Thermocouple Q340 There is a Q340 for every gas-fired heating system application. • Replace almost any 30 mV thermocouple. • Average operating life of ten years. • Available in a variety of lead lengths. Mfr#
Length (IN) Webb#
Q340A1066 Q340A1074 Q340A1082 Q340A1090 Q340A1108
18” 24” 30” 36” 48”
30876 30877 30878 30879 36216
F.W. Webb Company
105
8 Gas heating
mfr# 1970-018 1970-024 1970-030 1970-036 1970-048 1970-060 1970-072
1960-027 Low Mass Thermocouple
Thermocouples & Thermopile Generators
Pilot Burners & Orifices Anderson & Forrester Inc.
SECTION
SECTION
8
8
Gas Orifices & Gauging Drills Gauging Drill Kit — GDK4080
Plastic box contains 41 drill sizes: #40 – 80, and GB3020H tapered broach. Model# Description Webb# ANFGDK4080 Gauging Drill Kit 188739
Tapered Broach — GB3015 Gauging Drill Kit Tapered Broach
Three cornered broach. Tapered from .003” to .013”. A must for cleaning Pilot Orifices. Model# Description Webb# ANFGB3015 Three Cornered Broach 180504
Gauging Reamer Kit — GRK5000 Have the correct size reamer when you need it. Our kit contains each size in a slim plastic case.
Gauging Reamer Kit
Model# Description Webb# ANFGRK5000 Gauging Reamer Kit 180593 ANFGR5070 Gauging Reamer, #70, 5 PK 180602 ANFGRK080 Gauging Reamer, #80, 180598
Gas Orifices & Gauging Drills
Compression Fittings
Pilot Tube
Break-away type separates upon tightening.
Just bend and cut to length! Keep a few on your truck to take care of clogged pilots! 3/16” pilot tube, 17” long with 4 port orifice hood.
Model# Description Webb# ANFCF639 1/8” Short Breakaway Nut 180414 ANFCF640 3/16” Short Breakaway Nut 180415 ANFCF641 1/4” Short Breakaway Nut 180388 386449-1 1/4” Breakaway Nut 102371 ANFCF642 1/4” Medium Breakaway Nut 180599 EMPR1633-2 1/8” Long Breakaway Nut 181653 386449-4 1/4” Long Breakaway Nut 223431
RBS4590-065 RBS4590-067 RBS4590-069 RBS4590-071 RBS4590-072
Includes all tools needed to assemble MI100 adapters. Model# Description Webb# ANFMIK100 Master Adapter Kit 180533 ANFFMI100 Universal Adapter 180532
1/8” Short Breakaway Nut
3/16” Short Breakaway Nut 1/4” Short Breakaway Nut 3/8” Short Breakaway Nut
7/16” Short Breakaway Nut
Mfr# 10-383
The MIK131 orifice cabinet contains 23 of those orifices most commonly used. Over 300 orifices in proportion to normal demand. Model# Description Webb# ANFMIK131LP Orifice Assortment 188738
mfr# Description ANFCO400-72 LP, 1/2” Hex, 3/8-40 UNS ANFCO401 Blank, 1/2” Hex, 1/2-27 NPT ANFCO403 Bored, 1/2” Hex, 3/8-27 UNS ANFCO404 Blank, 9/16” Hex, 1/2-27 UNS ANFCO406 Blank, 1/2” Hex, 3/8-27 UNS
A full range of diameter sizes in 50’ lengths, and for convenience, 5’ lengths with fittings. Mfr# O.D. Size
181654 181729 93031 93030 93028 186719 189070
webb# 180416 180419 180421 180422 180424
Length webb#
11-016
7/16”
5’
94204
11-017
3/8”
5’
155172
11-191
1/8”
50’
153380
11-193
1/4”
50’
155171
11-195
3/8”
50’
155173
11-291
1/8”
5’
212789
11-292
3/16”
5’
73442
11-293
1/4”
5’
73443
Replacement Coil For 4075 Series Mfr# 40-752
description Replacement Coil
webb# 186651
8
In one kit you now have 32 of the most needed pilot orifices with over 100 pieces. These are replacement pilot orifices for Penn Baso, Robertshaw, General Controls, Honeywell and White-Rodgers. A must for every efficient serviceman. Cabinet is made of heavy gauge steel with durable baked enamel finish and radius bottom sections for easy removal.
mfr# Description webb# ANFPO505 Blank, 1/2” Hex, 1/8-27 NPT 180541 ANFPO508 Blank, 1/4” Hex, 1/4-28 UNF 180544 ANFPO511 Blank, 1/2” Hex, 7/16-27 UNS 180546 ANFPO518 Blank, 3/8” Round, 11/32-32 Special 180549
Anderson & Forrester Inc. Orifices mfr# 10-030 10-261
Model# Description Webb# ANFMI132 Pilot Orifice Assortment Kit 180534
Gas heating
Master Pilot Orifice Assortment Kit — MIK132LP
Gas Type tube size orifice size webb# LP 1/4” or 3/16” .010 186598 LP 1/4” .0088 186605
Master Orifice Kit
106
webb# 189026
Orifice Hex Plugs
Serviceman’s Orifice Kit
Serviceman’s Friend
description 3/16” X 17” Pilot Tube
Aluminum Tubing
Orifice Caps
Serviceman’s Orifice Assortment Kit — MIK131LP
Replacement Parts & Accessories
(cont.)
EMPR2972 1/4” Long Breakaway Nut EMPR1633-4-2 1/4” X 1/8” Long Breakaway Nut
Master Adapter Kit — MIK100
Master Adapter Kit
Pilot Burners & Orifices
Serviceman’s Friend — TL051
Pilot gas mfr# usage type
tube orifice size size webb#
For use with flow meter and other applications. One end of fitting has 1/8” pipe thread, 1/4” pipe thread and special 5/16” X 32 thread. Opposite end has regular hose fitting, also 1/8” straight pipe thread. Hose can be used on either end.
10-066 10-043 10-045
3/16”
#70 & #71 #70 & #71 #40A
NAT. NAT. & L.P. L.P.
3/16” 3/16”
.018 .014 .013
178927 85387 186600
F.W. Webb stocks barbeque grills and accessories, even turkey cookers!
Model# Description Webb# ANFTL051 Serviceman’s Friend 180578
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
107
Pilot Burners & Orifices
SECTION
8
8 Pilot Kits
Q314
1810-100 Universal 2BLC Pilot Uni-Kit®
1830-700 Pilot Electrode Series
Nonprimary-aerated, insert orifice type pilot burner for main burner ignition with Q340 or Q390 Thermocouple for Pilotstat safety control operation. • Use with Q313 Thermopile Generator for 750 mV powerpile applications.
The 1810-100 Universal 2 BLC Pilot Uni-Kit is designed to replace the obsolete Model 2B/2BLC Pilot which is no longer in production. The kit includes fittings for 1/4” tubing and an adapter and fittings to adapt to 3/16” tubing. Each kit comes with a Natural gas orifice installed and includes a separate L.P. gas orifice.
The 1830-700 Series Pilot Uni-Kits are designed for use with the O.E.M. style Pilot Ignition Systems. The electrode is permanently riveted to the pilot frame and the spark gap is fixed at 1/8”. These pilots can be used to replace existing pilot assemblies or when retrofitting standing pilot applications when and exact replacement is desired. Each Uni-Kit comes with a natural gas orifice installed and a separate L.P. gas orifice. Pilot tubing size is 1/4”.
Q314A4586 Q314A6094 Q314A4585
TYPE OF GAS
MOUNTING BRACKET
DIRECTION OF FRONT TIP
B
Front Left Right
LP; Natural
Webb# 80635 86742 86744
Q327 Primary-aerated, spud orifice-type pilot burner for main burner ignition with Q340 or Q390 Thermocouple for Pilotstat safety control operation. • Use with Q313 Thermopile Generator for 750 mV powerpile applications. Mfr# Q327A1626
Q347
DESCRIPTION TYPE OF GAS Webb# Bat Wing
88371
LP; Natural
Q345 Nonprimary-aerated, combination pilot burner and ignitor. Used with the S86, S8610, or S8670 in intermittent pilot systems. • Includes pilot burner with bracket, ceramic-insulated Kanthal flame rod/spark ignitor and ground strap. Mfr#
Direction of front tip
Q345A1305 Q345A1313
Front Left
TYPE OF GAS Webb# Natural
152195 152196
Q345A
Combination Type Pilot Burner The J991MDA-2 through J999MDA-2 models are universal replacement pilot burners for J10(-)DDA, J11(-)DDA (D10and D11) types. The pilot burners are individually packaged in a plastic bag. 10 bags per carton. Mfr#
TIP POSITION NATURAL GAS ORIFICE
J992MDA-2H J997MDA-2H J998MDA-2H J999MDA-2H
2 7 8 9
Y90AA-3223 Y90AA-3221 Y90AA-3223 Y90AA-3223
LP GAS ORIFICE
Webb#
Y90AA-4213 Y90AA-4211 Y90AA-4212 Y90AA-4212
183617 118696 118697 183554
Multi-Mount Universal Pilot Burner #8
J999MHA-2
#9
J999MKA-2
The J Series BASO universal replacement pilot burners are supplied in three models. Mounting brackets on all four sides of each burner permit adaptation to almost any application. The pilot burners are individually packed in a plastic bag. 10 bags per carton. • Three tapped holes in each bracket for vertical adjustment. • Natural and LP gas orifice supplied. • Nuts and bolts furnished in each package. Mfr#
J999MYA-2
108
J999MHA-2H J999MKA-2H J999MHA-2H
TYPE OF PILOT NATURAL GAS ORIFICE LP GAS ORIFICE “L” Channel Shell “Y” Channel
F.W. Webb Company
Y90AA-7223 Y90AA-7221 Y90AA-6221
Y90AA-4211 Y90AA-4210 Y90AA-4211
Webb# 118696 118699 183620
www.fwwebb.com
mfr# description 1810-100 Universal Pilot Uni-Kit
MFR# 1890-705
webb# 87067
Flame pattern type Standard
lead length 24”
1820 Series PG6 Replacement Pilot Uni-Kits®
1850/1851 Mini Pilot 100’s
The 1820 Series UniKits are designed to replace those hard-to-find ITT-General PG9 type pilots. Each Uni-Kit come with a natrual gas orifice installed and a separate L.P. gas orifice. A special 1/4” tubing adapter is provided that allows use of original tubing with nut and ball sleeve.
Mini-Pilot 100’s are nonaerated (no primary air) and can be used on all gases with no orifice change. The pilots are positionsensitive and care should be taken to install them in their correct position. (TOP stamped into casting at top when applied).
Flame pattern MFR# (Degrees) 1820-009 90 Right 1820-019
90 Left
1820-029
90 Right
1820-039
90 Left
type of gas Natural and L.P. Gas Orificies Included
with thermopile •
Webb# 186617
•
186618
Pilot Only
75116 755117
1830 (2CH & 2C) Incinerator-Target Pilot Uni-Kits® The 1930 Series Pilot Uni-Kit is designed to be used with all Uni-Line and competithive thermocouples. Kits include an adaptor that converts a threaded thermocouple/thermopile model 2CH to a snap-in thermocouple type model 2C. Each kit comes with a natural gas orifice installed, and a separate L.P. gas orifice. Hood MFR# type 1830-001 2 1830-002 1830-003 1830-004 1830-005 1830-011
5
mounting bracket type
6
2 4
flame pattern type Standard
Webb# 75118
90 Degrees Left
111048
90 Degrees Right
166784
25 Degrees Left
189032
3-Way (A)
111049
4
3-Way (C)
85399
90 Degrees Left
152595
1830-013
5
7
1830-015
3
4
1830-210
2
1830-213
4
1830-489
6
2 6
The F.W. Webb Heating Catalog
Standard
186622 75119
3-Way (A)
85434
3-Way (B )
192842
Tube MFR# Length Horizontal Angle Type #2 Kit 1851-051 24” 1851-052 36” Horizontal Angle Type #4 Kit 1851-152 36” Vertical Bottom Inlet Type #6 Kit 1851-252 24” 1851-253 36”
Inlet Size (Tubing)
Webb# 186617
Webb#
3/16” & 1/4”
192844 192845
3/16” & 1/4”
192847
3/16” & 1/4”
167046 85438
1890-100 (#11) Pilot Uni-Kit® The 1890-100 Pilot Uni-Kit includes fittings for 1/4” tubing and an adapter and fittings to adapt to 3/16” tubing. The kit comes with a Natural gas orifice instlled and includes a separate L.P. gas orifice. mfr# description 1890-100 36” Mini-Pilot, Type #6
webb# 167187
1898 Series Pilots 1898 Series Pilots are used with 4060 (MSA and MSC) Series Safety Valves. Suitable for natural or L.P. gas using the .14 universal orifice. MFR# 1890-022
tubing size 3/16”
tubing size Webb# .14 85384
Gas Ignition Controls Replacement Sensors mfr# 10-277
description S1 Sensor has 1/4” quick-connect terminal
F.W. Webb Company
webb# 203364
109
8 Gas heating
#2
#7
Pilot Burners & Orifices
Pilot Burner
Mfr#
Q314
SECTION
Hot Surface Ignitors
SECTION
SECTION
8
8
Regulators
Gas Ignition Controls
325 Series L-Model Line Regulators & OPDs, #2 Inlet Regulators
Robertshaw’s 41-400 Series Norton Hot Surface Ignitors deliver dependable ignition heating systems of every description. From furnaces and boilers to rooftop heaters, infrared burners, unit heaters, water heaters and many other types of HVAC equipment. The 41-400 Series Hot Surface Ignitors are made of high-purity recrystallized silicon carbide (Crystar™) which combines physical and thermal strength with stable electrical properties. The 41-400 Series are designed to reach ignition temperature(s) within 17 seconds. They have 8-gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity. The lead wires are also enclosed with a special high-temperature fiberglass insulation providing total electrical protection.
Features: • CSA certified for up to 5-psi inlet pressure. • Over-pressure protection device (OPD) to limit downstream pressure in case of regulator failure. • Maxitrol OPD approved and tested with the regulator. • Regulators or OPD’s can be ordered as separate items — or as a factory assembled unit. • Self-aligning valve with lever action for dead end regulator lockup. • Optional vent limiter eliminates the need to run vent piping to an outside area. Benefits: • Meets new ANSI standard Z21-80 for line pressure regulators — for use on piping systems such as CSST or semi-rigid copper tubing up to 5-psi. • OPD provides required downstream over-pressure protection for supply pressures in excess of 2-psi. • Pounds to inches regulator provides precise control from pilot flows to full regulator capacity. • Meets many utility specifications.
41-400 Series Hot Surface Furnace Ignitors
41-401
41-402
41-403
41-404
41-405
Factory lead wire MFR# Model length Webb# 41-401 271A 41/2” 73444 41-402 271W 19” 73445 41-403 51/2” 73446 271M 41-404 41/2” 110330 41-405 271D 51/2” 111617 41-406 271Y 101/2” 73447 111061 41-407 271 41-408 271N 153382 41-409 271 80697 41/2” 41-410 111618 271N 41-411 111619 41-412 271NM 51/2” 111620 41-413 201C 13/8” 189061
Outlet Pressure Range (all models) Certified spring, 7-11 in w.c. 41-406
41-407
41-408
Vent Limiters 41-409
41-411
mfr# webb# Automatic 12A04 77527 12A06 192793 12A09 109780 12A39 192794 Outdoor Vent Cap 13A15 246350
41-410
41-412
41-600 Series Hot Surface Furnace Mini-Ignitors
41-602
Robertshaw’s 41-600 Series Norton Hot Surface Mini-Ignitors deliver dependable ignition heating systems of every description. All Norton ignitors are engineered for easy handling, simple installation and trouble-free operation. MFR# 41-602 41-604 41-605
housing length None 4”
comments Amana #20165702 Armstrong #44744-2
Webb# 250353 241291
2.5”
York Replacement Conversion Kit #473-20937-001
241292
Glo-Stix™ are a durable universal direct upgrade for replacing most silicon carbide igniters.
URK24V
comments 24V Hot Surface Igniter 120V Flat Universal Kit
325-5AL-1
1” 1/2”
325-5AL-34
3/4”
325-5ALX-12
1/2”
325-7L-114
11/4”
325-7L-112
11/2”
3098-134
110
panel type
48”
E
F.W. Webb Company
description Gas Regulator, to 2 PSI
Webb# 252139
Gas Regulator, to 2 PSI
252140
Lever Operated Regulator
223959
252142 252141
2 PSI Inlet
224151
Attention: To comply with the
ANSI Z21-80 Standard for Line Pressure Regulators, installations exceeding 2-psi nominal require a tested and approved overpressure protection device (OPD) for use with the regulator. (Over-pressure protection is not required for supply pressures up to and including 2-psi.)
224152
Capacities and Pressure Drop — 2-psi, regulator only Model number (pipe size) 325-3L (3/8”, 1/2”) 325-5AL (1/2)” 325-5AL (3/4”, 1”)
MFR# OPD47 OPD48
Webb# 309804 268458
OPD600
Outlet Pressure Set Point 7.0” W.C. 10.0” W.C. 7.0” W.C. 10.0” W.C. 7.0” W.C. 10.0” W.C.
1/2 psi
(34 mbar) 145 (4.1) 110 (3.1) 335 (9.5) 150 (7.0) 335 (9.5) 150 (7.0)
Operating Inlet Pressure Max Capacity 3/4 psi 1 psi 11/2 psi 2 psi btu/hr (52 (89 (103 (138 Total load of all appliances mbar) mbar) mbar) mbar) 200 (5.7) 250 (7.1) 250 (7.1) 250 (7.1) 250,000 180 (5.1) 230 (6.5) 250 (7.1) 250 (7.1) 425 (12.0) 425 (12.0) 425 (12.0) 425 (12.0) 425,000 420 (11.9) 420 (12.0) 420 (12.0) 420 (12.0) 475 (13.5) 550 (15.6) 550 (15.6) 550 (15.6) 550,000 420 (11.9) 535 (15.1) 550 (15.6) 550 (15.6)
description
Webb#
3/8”, 1/2” — For use with 325-3LX 1/2” — For use with 325-3LX 1/2”, 3/4” — For use with 325-5ALX 3/4”, 1” — For use with 325-5ALX
2 lb. Pressure System
The Mercury Flame Sensor is a mechanical device that provides the existence of an acceptable pilot flame. When the bulb is heated by a pilot flame, the mercury is vaporized, causing pressure in the capillary and diaphragm, causing the snap-switch to open one set of contacts, and close a second set. These contacts control the pilot valve and the main valve. element Length
1/2”
325-5AL-12
Mercury Flame Sensors
MFR# 3098-134 3098-156
body sizes
OPD’s
Nitride Hot Surface Igniter MFR# URK24V URK120VF
MFR# 325-3L-12
bulb style #19 #20
description Replaces bulb styles #9 or #13. Replaces bulb styles #17 or #18.
Webb# 118711 205641
www.fwwebb.com
The F.W. Webb Heating Catalog
Length of Runs: A = 100’ B = 15’ C = 10’ D = 25’ E = 20’ Allowable drop: 1 PSI up to reg. 3” w.c.-reg. to appliance
F.W. Webb Company
8 Gas heating
41-605
Factory Model 601TB 601XBM 601XBM + Harness & Brackets
325-5ALX
111
Regulators
SECTION
SECTION
8
8
Rubber Seat Poppet Design Appliance Regulators
CounterStrike®
RV12, RV20, RV47 & CV47 and RV48 Main burner and pilot applications part number RV12 RV20 RV47 & CV47 RV48
RV12
RV20
RV47 & CV47
pipe sizes
capacities to 25 CFH 65 CFH 125 CFH 250 CFH
1/8” 1/4” & 3/8” 3/8” & 1/2” 1/2” & 3/4”
Part Number RV20L-38 RV47CL-12 RV47CL-38 RV47L-12 RV47L-38 RV48CL-12 RV48CL-34 RV48L-12 RV48L-34 RV48-12 RV48-34
Body Sizes
outlet pressures
inlet pressures to 1/2 psi (35 mbar) 2 psi
1.0” to 12” w.c.
1/2 psi (35 mbr)
description Gas Grill Regulator Appliance Regulator Nat. Appliance Regulator Regulator Nat. Appliance Regulator
3/8” 1/2” 3/8” 1/2” 3/8” 1/2” 3/4” 1/2” 3/4” 1/2” 3/4”
LP Appliance Regulator Nat. Appliance Regulator Gas Regulator
Webb# 185902 185903 188932 197256 188933 185905 185904 185907 185906 77528 77529
RV48
pipe sizes
Main Burner Range of Regulations 30,000 (.85)
1/8” X 1/8” 1/4” X 1/4” 3/8” X 3/8” 3/8” X 3/8” 1/2” X 1/2”
RV20 RV47 RV47A RV48
65,000 (1.84) 125,000 (3.5) 230,000 (6.5) 250,000 (7.1) 400,000 (11.3)
1/2” X 1/2” 3/4” X 3/4”
RV48C
As part of our ongoing process of continuing improvement, Omega Flex has developed an improved version of CounterStrike®. This is a second-generation product that is an effective but affordable tool in increasing the protection of CSST gas piping systems from the damage caused by nearby, indirect lightning strikes. This version takes CounterStrike’s proven capabilities to an even higher level. CounterStrike is a patented CSST innovation based on our existing TracPipe® CSST product, but that is engineered to significantly decrease the potential for lightning induced damage to fuel gas piping systems. CounterStrike has been designed with a proprietary jacket material in place of the standard yellow jacket. This black jacket has energy dissipating properties that will help protect the stainless steel pressure liner as well as other fuel gas system components if the CounterStrike becomes energized due to lightning. CounterStrike with the black, protective sleeve uses the same easy to install AutoFlare® with the yellow coating. It is sold on wooden reels of varying lengths to meet the needs of the gas piping contractor. CounterStrike meets building code requirements (ASTM E84) with respect to flame spread and smoke density. This permits installation in drop ceilings used as return air plenums, and is UL Listed for 1, 2, and 4 hour through penetration firestop systems without removal of the jacket.
Capacity Chart — expressed in Btu/h (cubic meters/h) — 0.64 sp gr gas part number RV12
Track Pipe, Yellow Gas Pipe Fittings & Accessories
MFG# Size REEL LENGTH FGPCS375-250 3/8 250 FGPCS500-250 1/2 250 fgpcs500-100 1/2 100 FGPCS750-250 3/4 250 FGPCS750-100 3/4 100 FGPCS100-180 1 180 FGPCS125-150 11/4 150 FGPCS150-150 11/2 150 FGPCS200-150 2 150
LB/REEL 29 40 22 55 22 60 66 91 92
webb# 368348 368160 368349 368159 368350 368344 368345 368346 368347
Contact your local F.W. Webb representative for certification information on TracPipe installation.
Note: Minimum main burner regulation capacity for all models (except “N”) is 150 Btu/h
8 Gas heating
Gas Valves 1751 Add-On Pressure Regulator Kits The 1751 Series Add-on pressure regulator kits are available for use on the following factory model types; 7000, 7010, 7100, 7200 & 7222. SUITABLE FOR
1751-003
MFR# 1721-003
REGULATOR TYPE 3.5” W.C. Nat. Gas
1751-007
Regulator Cover Plate
NAT. GAS
L.P. GAS
Webb# 85406 192839
F.W. Webb stocks Rinnai Continuums and the complete line of heaters!
4080 Pressure Regulators The 4080 Series Pressure Regulators are designed for main burner and pilot duty applications. The regulator is convertible with settings at 4” W.C. Natural gas and 10” W.C. L.P. gas on the 4080-032 and 4080-035. MFR#
pipe size
4080-035
3/4” X 3/4”
regulator type 4” (Fixed) W.C. Natural Gas 10” (Fixed) W.C. L.P. Gas
suitable for
Webb#
Nat. Gas
73478
4080-035
112
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
113
SECTION
SECTION
8
8
Track Pipe, Yellow Gas Pipe Fittings & Accessories
Track Pipe, Yellow Gas Pipe Fittings & Accessories
Flexible Gas Tubing MFG# Size Pkg. Qty
AutoFlare® Fittings Brass Fitting AutoFlare Insert Straight Mechanical Fittings, Reducing Fittings
webb#
Corrugated Stainless Steel 300 Series with Polyethylene Jacket TRPFGP-SS4-375-100 3/8” 100’ Reel 216967
Flexible Gas Tubing
TRPFGP-SS4-375-250
3/8”
250’ Reel
216966
TRPSS4-500-50
1/2”
50’ Reel
250003
TRPFGP-SS4-500-100
1/2”
100’ Reel
219618
TRPFGP-SS4-500-250
1/2”
250’ Reel
87389
TRPSS4-750-50
3/4”
50’ Reel
250003
TRPFGP-SS4-750-100
3/4”
100’ Reel
219619
TRPFGP-SS4-750-250
3/4”
250’ Reel
87390
TRPSS4-100-50
1”
50’ Reel
25000
TRPFGP-SS4-100-180
1”
180’ Reel
87391
TRPFGP-SS4-100-180
1”
180’ Reel
87391
TRPSS4-125-50
11/4”
50’ Reel
250001
TRPFGP-SS4-125-150
11/4”
150’ Reel
205453
TRPFGP-SS4-150-150
11/2”
150’ Reel
219620
TRPFGP-SS4-200-150
2”
150’ Reel
219621
Straight Fitting
Reducing Fitting
Termination Mount
90° Termination Mount
Meter Termination
fgp-ss4-375 fgp-ss4-500 fgp-ss4-750 fgp-ss4-1000 FGP-SS4-1250 FGP-SS4-1500 FGP-SS4-2000 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EDH (AGA Size)
15
19
25
Jacket O.D. (max.)
.668
.868
Inside Dia. (nom)
.440
.597
Wall Thickness (in.)
.01
.01
31
37
46
62
1,108
1.38
1,665
1,920
2,590
820
1.040
1,290
1,525
2,060
.01
.01
.012
.012
.012
Flange Mount Fitting
90° Elbow Flange Mount
Underground Gas Pipe
Underground Gas Pipe
114
1/2” 3/4”
1” 11/4” 11/4” 11/2” 11/2” 2”
F.W. Webb Company
100’ Coil 100’ Coil 100’ Coil 100’ Coil 100’ Coil 200’ Coil 100’ Coil 200’ Coil 200’ Coil
Straight Straight Straight Reducing Straight Reducing Straight Straight Straight
3/8” (1/2” NPT) 1/2” 3/4”
3/4” – 1/2” NPT
1” 1”– 3/4” NPT 11/4” 11/2” 2”
24/box 24/box 24/box 16/box 16/box 16/box 6/box 4/box 4/box
216968 87393 87394 219624 87395 219625 205454 219622 219623
Mounting Bracket
MFG#
type
pkg. qty. Size
TRPFGP-TM-375 TRPFGP-TM-500 TRPFGP-TM-750 TRPFGP-TM-1000 TRPFGP-90TM-375 TRPFGP-90TM-500 TRPFGP-MT6-500 TRPFGP-MT12-500 TRPMT6-750
Termination Mount Termination Mount Termination Mount Termination Mount 90° Termination Mount 90° Termination Mount 6” Meter Termination 12” Meter Termination 6” Meter Termination
12/Box 12/Box 8/Box 8/Box 8/Box 8/Box 1 ea. 1 ea. 1 ea.
3/8”
Flange Fittings TRPFGP-FF-375 TRPFGP-FF-500 TRPFGP-FF-750 TRPFGP-FF-1000 TRPFGP-FF-1250 TRPBFF-375 TRPBFF-500 TRPBFF-750 TRPBFF-1000 TRPFGP-BFF-114 TRPFGP-ELLS-375 TRPFGP-ELLS-500
Iron Flange Iron Flange Iron Flange Mount Iron Flange Mount Iron Flange Mount Brass Flange Brass Flange Brass Flange Brass Flange Flange Bracket 90° Elbow Flange Mount 90° Elbow Flange Mount
12/box 12/box 8/box 8/box 4/box
3/8”
TracPipe by TracPipe Outlet
MFG# Size Pkg. Qty webb# 3/8”
TRPFGP-FST-375 TRPFGP-FST-500 TRPFGP-FST-750 TRPFGP-RST750-500 TRPFGP-FST-1000 TRPFGP-RST1000-750 TRPFGP-FST-1250 TRPFGP-FST-1500 TRPFGP-FST-2000
pkg. qty. webb#
216985 216986 216987 216988 216989 241888 S720800 242755 242756
www.fwwebb.com
— — — — 1 ea. 8/box 8/box
webb# 217405 217406 217407 219626 217401 217402 246855 246856 250428
1/2” 3/4”
1” 3/8” 1/2” 1/2” 1/2” 3/4”
216975 87398 87399 87376 216976 153621 216963 216964 216965 222077 216981 216982
1/2” 3/4”
1” 11/4” 3/8” 1/2” 34” 1” All 3/8” 1/2”
8 Gas heating
* EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity. This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.
TRPUG375-100 TRPUG500-100 TRPUG750-100 TRPUG100-100 TRPUG125-100 TRPUG500-200 TRPUG150-100 TRPUG150-200 TRPUG200-100
type Size
Termination Mount, Meter Termination
Description/Dimensions
Part number Size (inch)
MFG#
TracPipe by Pipe Outlet
MFG#
type Size Pkg. Qty webb#
TRPFGP-TF500-T500 TRPFGP-TF750-T750 TRPFGP-TF1000T1000 TRPFGP-TF750-T500 TRPFGP-TF1000-T500 TRPFGP-CPLG-375 TRPFGP-CPLG-500 TRPFGP-CPLG-750 TRPFGP-CPLG-1000
Tee Tee Tee Tee Tee Coupling Coupling Coupling Coupling
1/2” X 1/2” 14/box 3/4” X 3/4” 12/box
1” X 1” 1/2” X 3/4” 1” X 3/4” 3/8” 1/2” 3/4” 1”
The F.W. Webb Heating Catalog
10/box — — 24/box 24/box 16/box 16/box
253452 222079 222081 222082 216977 216978 216979 216980
MFG#
type Size
TRPT500-500 TRPT750-750 TRPT750-500 TRPT1000-1000
Tee Tee Tee Tee
Tee
webb#
1/2” FIP 3/4” FIP 3/4” X 1/2” FIP
1” FIP
Coupling
222078 222084 S661838 222080
TracPipe by Pipe Outlet Tee
F.W. Webb Company
115
SECTION
SECTION
8
8
Track Pipe, Yellow Gas Pipe Fittings & Accessories TracPipe Accessories
Underground TracPipe Accessories
Spare Split Rings
Shrink Cuffs
MFG# Size
Full Striker Plate
Track Pipe, Yellow Gas Pipe Fittings & Accessories
TRPRING-375 TRPRING-500 TRPRING-700
(Two required for each run)
webb#
MFG# Size
222083 242572 242210
3/8” Spare 1/2” Spare 3/4” Spare
Shrink Cuffs
Striker Plates MFG# Description Size Pkg. Qty webb# Half Striker Quarter Striker
Floppy Strip Wound Conduit
TRPFGP-SP-025 TRPFGP-SP-050 TRPFGP-SP-100
Quarter Striker Plate Half Striker Plate Full Striker
3” X 2” 3” X 7” 3” X 12”
500/box 100/box 50/box
Vent Tees
87381 87380 87379
Pipe Wrap
Coated Manifold
3/4”
1” 11/4” 11/2” 2” 21/2”
50’ Coil 50’ Coil 25’ Coil 25’ Coil 25’ Coil 25’ Coil
1/2” 3/4”
1” 11/4” 11/2” 2”
216990 216991 216992 216993 216994 242757 242758
MFG# Size TRPVT-38 3/8” TRPVT-12 1/2” TRPVT-34 3/4” TRPVT-1 1” TRPVT-200 11/4” TRPVT-112 11/2” TRPVT-2 2”
webb# 216995 216996 216997 216998 216999 242759 242760
Underground TracPipe Pipe Wrap
MFG# Desc.
216969 216970 216971 216972 205456 216973
Tube Cutter
TRPTC-151 TRPTC-152
webb#
Tube Cutter for 3/8” – 11/4” Tube Cutter for 11/4” – 2”
242814 216984
MFG# Desc. TRP915-10H-12
Yellow Outdoor
webb# 242814
Bulk Hose
Manifold Bracket
Spiral Reinforced Series 7132 LP Gas Hose
Manifolds MFG# Description Size Pkg. Qty TRPFGP-MI-PC TRPFGP-MB2 TRPTERM-BRAC TRPP-LC
3/8”
TracPipe Tools
MFG# Description Size Pkg. Qty webb# Floppy Fits 3/8” Floppy Fits 1/2” Floppy Fits 3/4” Floppy Fits 1” Floppy Fits 11/4” Floppy Fits 2”
TRPHST-38 TRPHST-12 TRPHST-34 TRPHST-1 TRPHST-300 TRPHST-350-6 TRPHST-2
webb#
MFG# DESCRIPTION webb# TRPFGPGC-2 Bonding Clamp 1”–11/4” 373300 TRPFGPGC-1 Bonding Clamp 3/8”–1/2”– 3/4” 373301
Floppy Galvanized Steel Conduit TRPFGP-FPY-375-50 TRPFGP-FPY-500-50 TRPFGP-FPY-750-50 TRPFGP-FPY-1000-50 TRPFPY-1250 TRPFPY-1500
Vent Tees
(Use when required by local codes)
Coated Manifold 3/4” X 1/2” X 1/2”(4) Manifold Bracket * Flange L Bracket * Load Center w/Bracket *
1 ea. 1 ea. 1 ea. 1 ea.
webb# 246854 217403 222077 216983
Load Center w/Bracket
Features a smooth, abrasion resistant cover and the flexibility of the 4 spiral reinforcements result in a hose that is easier to handle and glides smoothly over any surface. • Tube: Black Nitrile. • Cover: Perforated Black Neoprene. • Reinforcement: Multiple Textile Braids. • Temp. Range: -50°F to 180°F.
8 Gas heating
mfr# DESC. Webb# HOS1X125WFIT 1” X 125’ 185593 HOS1X150WFIT 1” X 150’ 185595 HOS1X175WFIT 1” X 175’ 206544
F.W. Webb stocks miller furnaces!
Accessories Black Pipe Wrap Tape mfr# 9054 9052 16-002
116
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
size 4” X 100’ 2” X 100’ 2” X 100’ Yellow
webb# 75684 81161 72769
F.W. Webb Company
117
Track Pipe, Yellow Gas Pipe Fittings & Accessories
SECTION
SECTION
8
8
Track Pipe, Yellow Gas Pipe Fittings & Accessories
Dormont Stainless Steel Gas Connectors
Dormont Stainless Steel Gas Connectors
Residential Stainless Steel Gas Appliance Connectors
(cont.)
Dormont’s complete line of flexible, corrugated, Supr-Safe® stainless steel connectors attach all types of gas appliances to gas utility lines. . .easily and safely. We carry the largest inventory in the business, with connectors ranging from 3/8” through 11/2” O.D.
Stainless Steel Gas Connectors
F.W. Webb Company
Range Connectors with End Fittings (cont.) 30-4141-18 5/8” 1/2” 18” 3/4 mnpt 30-4141-24 5/8” 1/2” 24” 3/4 mnpt 30-4141-36 5/8” 1/2” 36” 3/4 mnpt 30-4144-18 5/8” 1/2” 18” 3/4 mnpt–3/4” mnpt 90 30-4144-24 5/8” 1/2” 24” 3/4 mnpt–3/4” mnpt 90 30-4144-36 5/8” 1/2” 36” 3/4 mnpt–3/4” mnpt 90 30-4144-48 5/8” 1/2” 48” 3/4 mnpt–3/4” mnpt 90 30-4242-18 5/8” 1/2” 18” 3/4 fnpt 30-4242-24 5/8” 1/2” 24” 3/4 fnpt 30-4242-36 5/8” 1/2” 36” 3/4 fnpt 30-4242-48 5/8” 1/2” 48” 3/4 fnpt 30-4242-60 5/8” 1/2” 60” 3/4 fnpt 30-4242-72 5/8” 1/2” 72” 3/4 fnpt 40-4142-24 1” 3/4” 24” 3/4 mnpt–3/4 fnpt
213943 213944 197947 67650 55306 67651 67653 55305 67652 55307 55308 185457 185459 184568
Stainless Steel Gas Connectors
End Fittings mfr# Description
webb#
Dryer 20 Series (Fittings for 1/2” OD Connectors) 90-2032 1/2” fnpt for 1/2” OD (3/8” ID) DOR90-2042 3/4” fnpt for 1/2” OD (3/8” ID) Dryer 30 Series (Fittings for 5/8” OD Connectors) 90-3031 1/2” mnpt for 5/8” OD (1/2” ID) 90-3041 3/4” mnpt for 5/8” OD (1/2” ID) 90-3032 1/2” fnpt for 5/8” OD (1/2” ID) 90-3042 3/4” fnpt for 5/8” OD (1/2” ID)
246634 179505 185463 209028 185462 185461
Commercial Supr-Safe® Disconnect Gas Appliance Connectors – BPQ Series Stainless Steel corrugated hose, encased in a stainless steel braid, covered with a thick Super-Flex coating and fitted with an A Type “Push-to-Connect” quick disconnect coupling.
Supr-Safe®
mfr# description 1/2” Quick Couplings 1650BPQ36 1/2” X 36” 3/4” Quick Couplings 1675BPQ36 3/4” X 36” 1675BPQ48 3/4” X 48” 1675BPQ60 3/4” X 60” 1675BPQB48 3/4” X 48” (B Type) 1” Quick Couplings 16100BPQ24 1” X 24” 16100BPQ36 1” X 36” Connectors with Restraining Device 1650BPQR36 1/2” X 36” Supr-Safe® Gas Connector Kits 1650KIT36 1/2” X 36” 1675KIT48 3/4” X 48” Supr-Swivel™ Kits with Restraining Device 1650BPQSR36 1/2” X 36”
webb# 213236 185435 185436 185438 204050 216370 216371 163869 163864 217546 163871
Replacement Gas Connectors with Plastic Coating 1650BP36 1/2” X 36” 163873 1675BP36 3/4” X 36” 163874 16100BP60 1” X 60” 242455
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
8 Gas heating
118
Description MFR# od id lENGTH tHREAD tYPE WEBB# Water Heater, Gas Log, Space Heater, Connectors with Fittings 10-2121-12 3/8” 1/4” 12” 3/8 mnpt end 242096 10-2121-18 3/8” 1/4” 18” 3/8 mnpt end 202067 10-2121-24 3/8” 1/4” 24” 3/8 mnpt end 185424 10-2121-30 3/8” 1/4” 30” 3/8 mnpt end 246859 10-2121-36 3/8” 1/4” 36” 3/8 mnpt end 244976 10-2121-48 3/8” 1/4” 48” 3/8 mnpt end 246858 10-2222-12 3/8” 1/4” 12” 3/8 fnpt end 185448 10-2222-18 3/8” 1/4” 18” 3/8 fnpt end 188283 10-2222-24 3/8” 1/4” 24” 3/8 fnpt end 215474 10-2222-36 3/8” 1/4” 36” 3/8 fnpt end 213164 10-2222-48 3/8” 1/4” 48” 3/8 fnpt end 245962 10-3131-12 3/8” 1/4” 12” 1/2 mnpt end 256880 10-3131-18 3/8” 1/4” 18” 1/2 mnpt end 209723 10-3131-24 3/8” 1/4” 24” 1/2 mnpt end 256858 10-3131-36 3/8” 1/4” 36” 1/2 mnpt end 209724 Dryer Connections with Fittings 20-2122-18 1/2” 3/8” 18” 3/8 mnpt/fnpt 163856 20-2122-30 1/2” 3/8” 30” 3/8 mnpt/fnpt 163857 20-2222-36 1/2” 3/8” 36” 3/8 fnpt 192747 20-2222-48 1/2” 3/8” 48” 3/8 fnpt 206103 20-3122-12 1/2” 3/8” 12” 1/2 mnpt–3/8 fnpt 191054 20-3122-18 1/2” 3/8” 18” 1/2 mnpt–3/8 fnpt 192608 20-3122-24 1/2” 3/8” 24” 1/2 mnpt–3/8 fnpt 191055 20-3122-36 1/2” 3/8” 36” 1/2 mnpt–3/8 fnpt 192613 20-3122-48 1/2” 3/8” 48” 1/2 mnpt–3/8 fnpt 192610 20-3122-60 1/2” 3/8” 60” 1/2 mnpt–3/8 fnpt 192611 20-3122-72 1/2” 3/8” 72” 1/2 mnpt–3/8 fnpt 191056 20-3131-12 1/2” 3/8” 12” 1/2 mnpt 166786 20-3131-18 1/2” 3/8” 18” 1/2 mnpt 209421 20-3131-24 1/2” 3/8” 24” 1/2 mnpt 166228 20-3131-36 1/2” 3/8” 36” 1/2 mnpt 209422 20-3131-48 1/2” 3/8” 48” 1/2 mnpt 166229 20-3131-60 1/2” 3/8” 60” 1/2 mnpt 209423 20-3132-36 1/2” 3/8” 36” 1/2 mnpt–1/2 fnpt 215815 20-3132-48 1/2” 3/8” 48” 1/2 mnpt–1/2 fnpt 224158 Range Connectors with Fittings 30-3131-12 5/8” 1/2” 12” 1/2 mnpt 245963 30-3131-18 5/8” 1/2” 18” 1/2 mnpt 218889 30-3131-24 5/8” 1/2” 24” 1/2 mnpt 193511 30-3131-30 5/8” 1/2” 30” 1/2 mnpt 201236 30-3131-36 5/8” 1/2” 36” 1/2 mnpt 79589 30-3131-48 5/8” 1/2” 48” 1/2 mnpt 179822 30-3131-60 5/8” 1/2” 60” 1/2 mnpt 212867 30-3131-72 5/8” 1/2” 72” 1/2 mnpt 218890 30-3132-24 5/8” 1/2” 24” 1/2 mnpt–1/2 fnpt 204534 30-3132-30 5/8” 1/2” 30” 1/2 mnpt–1/2 fnpt 163854 30-3132-48 5/8” 1/2” 48” 1/2 mnpt–1/2 fnpt 163855 30-3232-12 5/8” 1/2” 12” 1/2 fnpt 185449 30-3232-18 5/8” 1/2” 18” 1/2 fnpt 68547 30-3232-24 5/8” 1/2” 24” 1/2 fnpt 68548 30-3232-36 5/8” 1/2” 36” 1/2 fnpt 68549 30-3232-48 5/8” 1/2” 48” 1/2 fnpt 68692 30-3232-60 5/8” 1/2” 60” 1/2 fnpt 185458 30-3232-72 5/8” 1/2” 72” 1/2 fnpt 185460
Description MFR# od id lENGTH tHREAD tYPE WEBB#
119
Track Pipe, Yellow Gas Pipe Fittings & Accessories
SECTION
SECTION
8
8
Dormont Stainless Steel Gas Connectors
R. W. Lyall Propane Piping Systems
(cont.) Type S — “Push-To-Connect”
Lower Installation Costs — Fewer Repairs Over Time
Dormont makes connecting and disconnecting moveable/castered equipment easier and safer with the Supr-Quik® quick disconnect coupling (Type A). Supr-Quik® is the only quick disconnect coupling designed specifically for the needs of the foodservice industry. Features: • “Push-to-Connect” allows for easy one hand reconnect of gas line. mfr# A50 A75 Push-to-Connect
Gas Pipe, Tubing & Fittings
description 1/2” Quick Disconnect Fitting 3/4” Quick Disconnect Fitting
Residential Application
The LycoFit® connection system by Lyall, which requires no pipe preparation or special training, is much easier and faster to install compared to other mechanical fittings, electrofusion, and thermal fusion methods. Even more important is that installation failures due to bad pipe cuts, poor fusion, and weak connections are eliminated in the process. Add to that the durability of Lyall chemically resistant fittings and you will no longer have to concern yourself with re-installation due to typical joint failures.
webb# 163860 163861
Multi-Plane Supr-Swivel™ Fitting The Multi-Plane Supr-Swivel™ fitting is designed to meet the challenges that a gas connector faces in action. It dramatically increases the connector’s range of movement and flexibility. As castered equipment is moved in and out and from side to side the gas connector is subject to stress in multiple places. Only the Dormont Multi-Plane Supr-Swivel™ can relieve these multiple stresses. mfr# S75
Supr-Swivel™
description 3/4” Gas Swivel Connector
webb# 163859
Coiled Restraining Device For maximum safety, a restraining device in required under the ANSI & CGA standards for the safe installtion of all types of moveable/castered gas appliances. Dormont also include commercial mounting hardware to attach the heavy duty restraining device to both the wall and equipment. mfr# description Restraining Device Coils RDC-36 for 36” Commercial flex RDC-48 for 48” Commercial flex
Coiled Restraining Device
LYCOFIT® Mechanical Fittings
webb# 163862 163863
Fitting — (for use with Dormont Gas Connectors Only) description webb# 1/2” Flare X 1/2” MIP (Tapped 3/8” FIP) 215631
• 100% leak-proof, easy to install. • Cost effective, maintenance free joining system. • Unprecedented performance levels and proven reliability. • Excellent durability resistant to harsh chemicals and cracking. • Simple installation, no fusion equipment required. • No measuring or calculating required. • Absolutely no slippage or pull-out.
Victor, F.W. Webb’s lp gas division, has their own web site: www.victormfg.com
F.W. Webb Company
LYCOFIT® is a mechanical fitting for connecting underground Polyethylene (PE) gas piping systems. Lyall offers over 900 configurations allowing for varied installation requirements. Patented 100% Leak-Proof Design The LYCOFIT® fitting takes advantage of the natural sealing properties of the PE pipe, in a superior patented design that uses a barbed spigot to seal the inside diameter (ID) of the PE gas pipe, and a completion sleeve that provides the force necessary for a leak-proof, reliable connection every time. By using the polyethylene as the gasket material, this assures a positive seal between the coupling and the pipe regardless of the outside condition of the pipe. The system eliminates the use of O-rings and rubber gaskets that could leak on scratched pipe or deteriorate under adverse conditions like exposure to chemicals. Compact LYCOFIT® designs allow for installation in confined spaces. Eliminates Pull-Out The design provides a connection so strong that it provided enough gripping power to eliminate pull-out 100% of the time. In ASTM Quick Burst and Tensile Testing, PE Pipe fails before the LYCOFIT® coupling every time! Instant Visual Check LYCOFIT® provides the installer with a full visual quality check — first “pipe-on” and the “sleeve on” in each installation for a gas tight connection.
Contact your local F.W. Webb representative for certification information for Lyall products.
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
121
8 Gas heating
mfr# 70-3031
120
Lyall provides a wide variety of product sizes and configuration to meet residential needs.
SECTION
SECTION
8
8
Gas Pipe, Tubing & Fittings R. W. Lyall Propane Piping Systems
R. W. Lyall Propane Piping Systems
(cont.)
LYCOFIT® Mechanical Fittings mfr# description PE Pipe to Copper Tube Adapter
webb#
Double End Couplings
1/2” CTS 1” CTS 1” CTS 1/2” IPS 3/4” IPS 1” IPS 11/4” IPS 11/2” IPS 2” IPS
183448 179004 179005 183453 183449 183450 183451 179012 183452
Stop & Go Couplings
LYCLC010B-SGR LYCLC050W-SGR LYCLC060Y-SGR
1/2” CTS 1/2” IPS 3/4” IPS
mfr# description Webb# 3-Way Tee Couplings
179025 179027 179028
LYCLC010B-3TR LYCLC030B-3TR LYCLC050W-3TR LYCLC060Y-3TR LYCLC070Y-3TR LYCLC090Y-3TR LYCLC200Y-3TR
1/2” CTS
1” CTS 1/2” IPS 3/4” IPS 1” IPS 11/4” IPS 2” IPS
179029 179031 183470 183467 179037 183520 183469
90° Elbow Couplings
LYCLC010B-ELR LYCLC030B-ELR LYCLC060Y-ELR LYCLC070Y-ELR LYCLC080X-ELR
1” CTS 3/4” IPS 1” IPS 11/4” IPS
179040 179042 183458 183459 183460
11/4” IPS 2” IPS
179086 179087
1/2” CTS
Repair Couplings
Reducer Couplings LYCLC080X-DER LYCLC200Y-DER 1/2” CTS X 1/2” CTS 1” CTS X 1/2” CTS 1” CTS X 1/2” IPS 1” CTS X 3/4” IPS 11/4” CTS X 1/2” CTS 1/2” IPS X 1/2” CTS 3/4” IPS X 1/2” CTS 3/4” IPS X 1/2” IPS 1” IPS X 1/2” CTS 1” IPS X 1/2” IPS 1” IPS X 3/4” IPS
1” IPS X 1” CTS 2” IPS X 11/4” IPS
179063 179066 179067 179068 179069 179073 193507 179074 179077 182465 179080 179081 179084
mfr# description Mechanical Tapping Tees LC080010B-TT 11/4” IPS X 1/2” CTS LC080030D-TT 11/4” IPS X 1” CTS LC080050W-TT 11/4” IPS X 1/2” IPS LC080060Y-TT 11/4” IPS X 3/4” IPS LC080070Y-TT 11/4” IPS X 1” IPS LC200010B-TT 2” IPS X 1/2” CTS LC200030B-TT 2” IPS X 1” CTS LC200050W-TT 2” IPS X 1/2” IPS LC200060Y-TT 2” IPS X 3/4” IPS LC200070Y-TT 2” IPS X 1” IPS
webb#
mfr# description Webb# Anodeless 90° Bend Rigid Riser
179131 179133 216004 179141 179143 198639 216006 179154 179156 179157
LYCSTDLY050010T LYCSTDLY060010T LYCSTDLY060050T LYCSTDLY060060T LYCSTDLY070010T LYCSTDLY070030T LYCSTDLY070050T LYCSTDLY070060T LYCSTDLY070070T LYCSTDLY080080T LYCSTDLY090090T LYCSTDLY200200T
Test Cap, Mechanical Tapping Tees LCTESTCAP Fits all Lyall Mechanical Tapping Tees
Transition Fittings
mfr# Threaded Steel End LYCLT060S060Y-BT LYCLT070S030B-BT LYCLT070S070Y-BT LYCLT080S080X-BT LYCLT090S090Y-BT LYCLT200S200Y-BT
Anodeless Flexible Riser
description 3/4” NPT X 3/4” IPS 1” NPT X 1” CTS 1” NPT X 1” IPS 11/4” NPT X 11/4” IPS 11/2” NPT X 11/2” IPS 2” NPT X 2” IPS
webb# 198865 202405 198870 215614 202399 202400
LYCSTDLY060010FX-T 3/4” NPT X 1/2” CTS LYCSTDLY060050FX-T 3/4” IPS X 1/2” IPS LYCSTDLY060060FX-T 3/4” IPS X 3/4” IPS LYCSTDLY070010FX-T 1” NPT X 1/2” CTS LYCSTDLY070050FX-T 1” NPT X 1/2” IPS LYCSTDLY070060FX-T 1” IPS X 3/4” IPS
192494 192628 192630 192631 192632 192634
Anodeless LPG Flexible Tank Risers
End Caps
LYCLC010B-ECR LYCLC050W-ECR LYCLC060Y-ECR LYCLC070Y-ECR LYCLC080X-ECR LYCLC200Y-ECR
1/2” CTS 1/2” IPS 3/4” IPS
1” IPS 11/4” IPS 2” IPS
179014 183457 179021 183455 179023 179024
Lyall Polyethylene Ball Valves Available through special order. Continental Fittings Continental Chamber Tools Lyall Sourceheadness
1” NPT X 1” IPS 11/4” NPT X 11/4” IPS 2” NPT X 2” IPS
8
252451 252452 252456
Lyall Meter Manifolds mfr# Manifolds, Multi-Meter LYCM080KPL070C LYCM080KPL070A
description 1 1/4” X 3 Port 1 1/4” X 1 Port
webb# 318127 318128
Manifolds, Corrugated Stainless Steel Tubing (CSST)
Steel Pipe to PE Pipe Transitions 3/4” NPT X 3/4” IPS
LYCSTDLY050010FX-PGS 1/2” NPT X 1/2” CTS LYCSTDLY050050FX-PGS 1/2” NPT X 1/2” IPS LYCSTDLY060060FX-PGS 3/4” NPT X 3/4” NPT
183510 183511 183512 179062
LYCMIP0600600504PD
www.fwwebb.com
3/4” NPT X 1/2” NPT, 4 Outlets
252464
Brackets for Risers & Manifolds LYCBRKL-9 LYCBRKL-6
F.W. Webb Company
1” NPT X 1” CTS 1” NPT X 1/2” IPS 1” NPT X 3/4” IPS 1” NPT X 1” IPS 11/4” NPT X 11/4” IPS 11/2” NPT X 11/2” IPS 2” NPT X 2” IPS
193302 192989 180062 180063 193893 193894 193895 193896 183406 180066 193897 193898
LYCLC060S060Y-SPB LYCLC070S070Y-SPB LYCLC080S080X-SPB LYCLC200S200Y-SPB
122
1/2” NPT X 1/2” CTS 3/4” NPT X 1/2” CTS 3/4” NPT X 1/2” IPS 3/4” NPT X 3/4” IPS 1” NPT X 1/2” CTS
The F.W. Webb Heating Catalog
9” Wall Mount 6” Wall Mount
F.W. Webb Company
253223 252457
123
Gas heating
LYCLC010B010A-RR LYCLC030D010B-RR LYCLC030D050W-RR LYCLC030D060Y-RR LYCLC040B010B-RR LYCLC050W010B-RR LYCLC060Y010B-RR LYCLC060Y050W-RR LYCLC070Y010B-RR LYCLC070Y050W-RR LYCLC070Y060Y-RR LYCLC070Y030B-RR LYCLC200Y080X-RR
(cont.) Lyall Risers
Lycofit® Mechanical Tapping Tees
LYCLC375010B-GCR 3/8” O.D. Flare X 1/2” CTS 179091 LYCLC500010B-GCR 1/2” O.D. Flare X 1/2” CTS 179093
LYCLC010B-DER LYCLC030B-DER LYCLC030D-DER LYCLC050W-DER LYCLC060Y-DER LYCLC070Y-DER LYCLC080X-DESR LYCLC090Y-DESR LYCLC200Y-DESR
Gas Pipe, Tubing & Fittings
Gas Pipe, Tubing & Fittings Continental Con-Stab I.D. Seal Fittings mfr# Full Coupling LYC3259-52-1012-00 LYC3259-52-1013-00 LYC3259-52-1014-00 LYC3259-52-1015-00 LYC3259-52-1017-00 LYC3259-52-1004-00
description
webb# 269238 269239 269289 269240 269241 269237
Reduced Couplings LYC3259-54-1404-00 LYC3259-54-1304-00 LYC3259-54-1204-00 LYC3259-54-1312-00 LYC3259-54-1413-00 LYC3259-54-1513-00 LYC3259-54-1514-00 LYC3259-54-1715-00
1” IPS X 1/2” CTS 3/4” IPS X 1/2” CTS 1/2” IPS X 1/2” CTS 3/4” IPS X 1/2” IPS 1” IPS X 3/4” IPS 11/4” IPS X 3/4” IPS 11/4” IPS X 1” IPS 2” IPS X 11/4” IPS
269254 269252 269251 269253 269255 269256 269257 269258
90 Degree Elbows LYC3259-51-1012-00 LYC3259-51-1013-00 LYC3259-51-1014-00 LYC3259-51-1015-00 LYC3259-51-1017-00 LYC3259-51-1004-00
1/2” IPS 3/4” IPS 1” IPS 11/4” IPS 2” IPS 1/2” CTS
269219 269220 269221 269222 269223 269218
1/2” IPS 3/4” IPS 1” IPS 11/4” IPS 2” IPS 1/2” CTS
269213 269214 269215 269216 269217 269212
Reducing Tee’s LYC3259-49-1304-00 LYC3259-49-1404-00 LYC3259-49-1413-00 LYC3259-49-1715-00
3/4” IPS X 1/2” CTS 1” IPS X 1/2” CTS 1” IPS X 3/4” IPS 2” IPS X 11/4” IPS
269259 269260 269261 269262
3/4” IPS 1” IPS 11/4” IPS 2” IPS 1/2” CTS
8
8
269264 269265 269266 269267 269263
mfr# Double End Couplings LYCLC050W-DER LYCLC060Y-DER LYCLC070Y-DER LYCLC080X-DESR LYCLC090Y-DESR LYCLC0200Y-DESR LYCLC010B-DER Stop and Go Couplings LYCLC050W-SGR LYCLC060Y-SGR LYCLC010B-SGR Reduced Couplings LYCLC050W010B-RR LYCLC060Y010B-RR LYCLC060Y050W-RR LYCLC070Y060Y-RR LYCLC070Y50W-RR LYCLC070Y010B-RR 3 Way Tee’s LYCLC050W-3TR LYCLC060Y-3TR LYCLC070Y-3TR LYCLC090Y-3TR LYCLC080X-3TR LYCLC200Y-3TR LYCLC010B-ELR 90 Degree Elbows LYCLC060Y-ELR LYCLC070Y-ELR LYCLC080X-ELR LYCLC090Y-ELR LYCLC010B-ELR
Gas Pipe, Tubing & Fittings LYCOFIT® Installation Tools
R.W. Lyall Risers (Required Coupling)
description Webb#
1” IPS 11/4” IPS 11/2” IPS 2” IPS 1/2” CTS
183453 183449 183450 183451 179012 183452 183448
1/2” IPS 3/4” IPS 1/2” CTS
179025 179028 179025
1/2” IPS 3/4” IPS
179073 193507 179074 179080 182465 179077
1/2” IPS X 1/2” CTS 3/4” IPS X 1/2” CTS 3/4” IPS X 1/2” IPS 1” IPS X 3/4” IPS 1” IPS X 1/2” IPS 1” IPS X 1/2” CTS
183470 183467 179037 183520
1/2” IPS 3/4” IPS
1” IPS 11/4” IPS 11/2” IPS 2” IPS 1/2” CTS
183469 179040
mfr# Anodeless Rigid Risers
size
LYCSTDLY050010T LYCSTDLY060050T LYCSTDLY060060T LYCSTDLY070070T LYCSTDLY080080T LYCSTDLY090090T LYCSTDLY200200T
(NPT OUTLET X PE INLET) 1/2” NPT X 1/2” CTS 3/4” NPT X 1/2” IPS 3/4” NPT X 3/4” IPS 1” NPT X 1’ IPS 11/4” NPT X 11/4” IPS 11/2” NPT X 11/2” IPS 2” NPT X 2” IPS
webb#
193302 180062 180063 183406 180066 193897 193898
Adoneless Flexible Risers (48”) LYCSTDLY060010FX-T LYCSTDLY060050FX-T LYCSTDLY060060FX-T
3/4” NPT X 1/2” CTS 3/4” IPS X 1/2” IPS 3/4” IPS X 3/4” IPS
192494 192628 192630
Transition Fittings (Threaded Steel X PE Pipe) 16” Overall Length LYCLT060S060Y-BT 3/4” NPT X 3/4” IPS 198865 LYCLT070S070Y-BT 1” NPT X 1” IPS 198870 LYCLT080S080X-BT 11/4” NPT X 11/4” IPS 215614 LYCLT200S200Y-BT 2” NPT X 2” IPS 202400
mfr#
size Webb#
Service Head Flexible Risers 48” Tank Risers (No Coupling Required) 183458 183459 183460
3/4” IPS 1” IPS 11/4” IPS 11/2” IPS 1/2” CTS
179040
Repair Couplings Call Victor Mfg.
LYCSHAFC050010B-48 LYCSHAFC050050W-48 LYCSHAFC060060Y-48
183510 183511 183512 179062
1/2” NPT X 1/2” CTS 1/2” NPT X 1/2” IPS 3/4” NPT X 3/4” IPS
261880 261881 261884
Dual Quick Ratchet Press (QRP-200) Designed for manual installations, the dual ratchet design of the QRP-200 makes it simple to install of medium to large sized piping systems. Installs all LYCOFIT® couplings from 3/4” IPS through 2” IPS.
mfr# LYCQRP-100
description 1/2” CTS — 1” IPS
webb# 179095
Accessories for QRP Tool mfr# description Pipe Jaw Vise-Grip LYCAPJ010 LYCAPJ050 LYCAPJ060 LYCAPJ070 LYLF-BOXQRP
1/2” CTS 3/4” CTS / 1/2” IPS
1” CTS / 3/4” IPS 11/4” CTS / 1” IPS Tool Box for QRP-100
webb#
183540 179097 179098 183518 179100
8
Time is money
Service Head Flexible Risers 84” LYCSHAFC050010B-84 LYCSHAF050050W-84 LYCSHAFC060060Y-84
Steel Pipe to PE Transitions (With Mechanical Coupling) LYCLC060S060Y-SPB 3/4” NPT X 3/4” IPS LYCLC070S070Y-SPB 1” NPT X 1” IPS LYCLC080S080X-SPB 11/4” NPT X 11/4” IPS LYCLC200S200Y-SPB 2” NPT X 2” IPS
Tools that make every job quick and easy LYCOFIT® Tools allow for quick and easy installation of LYCOFIT® fittings. These tools provide perfect alignment and precision installment each and every time, without special training or time consuming measurements required. Quick Ratchet Press (QRP-100) The QRP-100 is a light weight, durable, single ratchet field assembly tool that installs all LYCOFIT® couplings from 1/2” CTS/IPS through 1” CTS.
1/2” NPT X 1/2” CTS 1/2” NPT X 1/2” IPS 3/4” NPT X 3/4” IPS
261885 261886 261889
PE Coated 12 ga.-500’
359306
500’
183516
To make sure you do each operation quickly, easily, and properly every time Lyall offers the right tools to assure the job is done correctly.
Locator Wire VCTTRACERWIRE Detection Tape “Caution Gas Line Below” MISUD21
124
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
125
Gas heating
3 Way Tee’s LYC3259-50-1012-00 LYC3259-50-1013-00 LYC3259-50-1014-00 LYC3259-50-1015-00 LYC3259-50-1017-00 LYC3259-50-1004-00
Repairing Couplings LYC1359-56-1200-00 LYC1459-56-1200-00 LYC3238-14-4415-00 LYC3238-14-4417-00 LYC0459-56-1200-00
SECTION
Lycofit Mechanical Fittings
3/4” IPS 1” IPS 11/4” IPS 2” IPS 1/2” CTS
1/2” IPS
SECTION
Gas Pipe, Tubing & Fittings R.W. Lyall Propane Piping Systems (cont.)
webb# 183440 183535
Accessories for LAP Tool mfr# Pipe Clamp
LYCAPJ080-1 LYCAPJ090 LYCAPJ200-1 LYCAPJ200PB-01 LYCLF-BOXLAP
description
Standard – 11/4” IPS Standard – 11/2” IPS Standard – 2” IPS Pull-Back – 2” IPS Tool Box for LAP-100
webb#
179105 193027 179105 179108 179109
Specifications • Meets or exceed all requirements for the Categorization of Mechanical Fittings within ASTM D2513-90c Category 1, and requirements from the Code of Federal Regulations, Title 49 Part 192.281 and 192.283. • Meets or exceeds NFPA-58 – 1002, DOT and ISO requirements. • Listed with IAPMO/UPS and CSA • Conforms to the Mechanical Fitting Specification as defined in ASTM F 1924. A complete set of specifications and test results for the product are available upon request.
F.W. Webb Company
8
8
Yellow Plastic Gas Pipe
mfr# Description Webb# IPS Sizes YGP12SDR93-50 1/2” IPS X 50’ 165570 YGP12SDR93-100 1/2” IPS X 100’ 165738 YGP12SDR93-150 1/2” IPS X 150’ 165739 YGP12SDR93-200 1/2” IPS X 200’ 165740 YGP12SDR93-500 1/2” IPS X 500’ 183399 YGP34SDR11-50 3/4” IPS X 50’ 165571 YGP34SDR11-100 3/4” IPS X 100’ 165741 YGP34SDR11-150 3/4” IPS X 150’ 165742 YGP34SDR11-500 3/4” IPS X 500’ 183429 YGP1SDR11-100 1” IPS X 100’ 165572 YGP1SDR11-150 1” IPS X 150’ 165743 YGP1SDR11-200 1” IPS X 200’ 165744 YGP1SDR11-500 1” IPS X 500’ 183430 YGP114SDR10-100 11/4” IPS X 100’ 165574 YGP114SDR10-150 11/4” IPS X 150’ 165747 YGP114SDR10-200 11/4” IPS X 200’ 165748 YGP114SDR11-100 11/4” IPS X 500’ 165573 YGP114SDR11-150 11/4” IPS X 150’ 165745 YGP114SDR11-200 11/4” IPS X 200’ 165746 YGP114SDR11-500 11/4” IPS X 500’ 183431 YGP112DR11-150 11/2” IPS X 150’ 165575 YGP112SDR11-500 11/2” IPS X 500’ 183432 YGP2SDR11-50 2” IPS X 15’ 165776 YGP2SDR11-100 2” IPS X 100’ 165749 YGP2SDR11-150 2” IPS X 150’ 165750 YGP1DR11-200 2” IPS X 200’ 165751 *YGP3SDR115-200 2” IPS X 500’ 165752 *YGP3SDR11-500 3” IPS X 500’ 165752 *YGP4SDR115 4” IPS 165579 * Special Order CTS Sizes YGP12CTS090-100 1/2” CTS X 100’ YGP12CTS090-200 1/2” CTS X 200’ YGP12CTS090-500 1/2” CTS X 500’ YGP12CTS099-50 1/2” CTS X 50’ YGP12CTS099-100 1/2” CTS X 100’ YGP12CTS099-300 1/2” CTS X 300’ YGP1CTS099-75 1” IPS X 75’ YGP1CTS099-150 1” IPS X 150’ YGP1CTS099-200 1” IPS X 200’ YGP1CTS099-300 1” IPS X 300’ YGP1CTS099-500 1” IPS X 500’ YGP1CTS102-75 1” IPS X 75’ YGP1CTS102-150 1” IPS X 150’
193140 193141 183524 202853 165581 203239 165762 165754 165755 165756 183525 165763 165758
www.fwwebb.com
Shut Offs
Gas Ball Valves Models T-204 – System 2®
The new Jomar System-2 FIP to Flare, Flare to Flare and MIP to Flare valves are new products with vision. Equipped with all the features of the Blue-Cap®. • Raised wrench flats for installation ease. • It can be used in temperatures from -40°F to 300°F, making it ideal for outside use in extremely cold or warm climates. • The T-handle can be reversed into a locked position, by turning the handle to the off position, removing the tamper proof alien screw and reversing the handle 180° into the slot. • Each valve is shipped with plastic thread protectors to prevent leak causing nicks. • AGA and CGA design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/air mixture. • AGA and CGA listed 0.5, 2 lb, 5 lb, System. Mfr# Desc. Webb# Model T-204 – FIP x FL JOM101-502 1/2” x 3/8” FIP X FL JOM101-503 1/2” FIP X FL
165040 58791
Model T-203 – System 3® Equipped with all the features of the Blue-Cap®, the System-3 has additional features making it the best value on the valve market today. • A 1/8” NPT side tap allows a manometer to be inserted into the valve to test line pressure, eliminating the test tee and the labor to install it. • It can be used in temperatures down to -40°F to 300°F, making it ideal for outside use in extremely cold or warm climates. • The handle can be reversed into a locked position. Combined with the tamper proof screw, the possibility of unauthorized use is sharply reduced. • AGA and CGA design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/ air mixture. • UL Listings: LP Gas, flammable liquids, natural and manufactured gas, air, N2,inert gases including helium, CO2. • The valve is rated 150 WSP/600 WOG. Remove the plug and you have a drainable ball valve for any fluid system. Mfr# Desc. Webb#
Model T-204 – FL x FL JOM101-601 1/2” x 3/8” FL X FL JOM101-602 3/8” FL X FL JOM101-603 1/2” FL X FL JOM101-604 5/8” FL X FL
178937 184941 184942 184940
Model T-204 – MIP x FL JOM101-702 1/2” X 3/8” MIP X FL JOM101-703 3/8” MIP X FL
164856 164857
Model T-204 – System 3®
Model T-203 – FIP X FIP JOM102-301 3/4” FIP X 5/8” FL JOM102-203 3/4” FIP X 5/8” FL JOM102-303 1/2” FIP With Side Tap JOM102-304 3/4” FIP With Side Tap JOM102-305 1” FIP With Side Tap
178938 151303 151304 151305 178939
Model T-203 – FL X FL JOM102-402 3/8” FL With Side Tap JOM102-403 1/2” FL With Side Tap JOM102-404 5/8” FL With Side Tap JOM102-405 1/2” FEM X FL Side Tap
151306 151307 151308 167285
8
Jomar’s Blue Cap® II Manual Gas Valve, Model T-204 is American Gas Association Laboratories design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/air mixtures. The Blue Cap® II may be used as a 150lb. steam valve/600 W.O.G.
Gas heating
LycoRing® Lightweight, disposable plastic ring that easily slips over the PE pipe and securely grips the pipe while inserting the pipe onto the LYCOFIT® spigot. The LycoRing® is included with the matching LYCOFIT® fitting and can be used with all LYCOFIT® configurations that use QRP and LAP tools, including tapping tee outlets. LycoRing® is provided with each LYCOFIT® fitting and eliminates the need for additional gripping tools to install fittings.
126
SECTION
Pressure rated PE 2406 IPS and CTS Gas pipe for natural gas distribution and service lines.
Large Auto Press (LAP-100) This heavy duty hydraulic tool is designed to provide thousands of worry free installations quickly and easily. Installs 11/4”, 11/2” and 2” IPS LYCOFIT® couplings. mfr# description Hydraulic Tool & ENERPAC™ LYCLAP100 11/4” IPS — 2” IPS LYCAHP100 ENERPAC™
SECTION
Mfr# Desc. Webb# Model T-204 – FIP X FIP JOM101-401 1/2” FIP X FIP JOM101-402 3/8” FIP X FIP JOM101-403 1/2” FIP X FIP JOM101-404 3/4” FIP X FIP
184937 184938 184939 184935
Model T-204 – With Tear Drop Handle JOM101-413 1/2” FIP JOM101-414 3/4” FIP
184575 184576
The F.W. Webb Heating Catalog
• • • • •
Is wholesale only is made in the usa has true 40,000 btu’s on 40 gallon has a patented “hydrojet” system Has a patented 304L Stainless Steel “Screenlock” system • has a factory installed T&P valve • has a patented “vitraglass” lining
F.W. Webb Company
127
SECTION
8
Shut Offs Gas Ball Valves T-2000N Series
Blue Top® Gas Ball Valves CSA Certified One Piece Design mfr# description Lever Handle Model T-3000 101-025 1” T-1001 IPS 101-026 11/4” T-1001 IPS 101-027 11/2” T-1001 IPS 101-028 2” T-1001 IPS
webb# 75918 75919 75920 75921
Flare Valves 102-112 3/8” Flare X 1/2” FIP 102-113 1/2” Flare X 1/2” FIP 102-118 1/2” Flare X 3/4” FIP 102-114 5/8” Flare X 3/4” FIP
75914 75915 75916 73309
102-212 102-213
3/8” Flare X 1/2” MIP
73307 73308
102-312 102-313 102-314
3/8” Flare X 3/8” Flare
1/2” Flare X 1/2” MIP
1/2” Flare X 1/2” Flare 5/8” Flare X 5/8” Flare
75911 75912 75913
T-Handle Model T-3001 Massachusetts Code 101-612 3/8” T-3001 IPS 75917 101-613 1/2” T-3001 IPS 57841 101-614 3/4” T-3001 IPS 57842
Jomar’s T-2000N Series of steel valves are designed for rugged industrial applications of steam, water, oil, gas and corrosive materials. They are UL approved for LP gas, natural and manufactured gas, LP gas air mixtures and anhydrous– ammonia. They feature solid ball construction, 2nd generation P.T.F.E. seats, two piece standard port design. Double Viton O-Rings prevent stem leakage. Special 2000 PSI seats available upon request. • Conforms to federal specification WW-V-35. • Latch-Lock Feature: Valve comes complete with latch lock, which may be locked in open or closed position. • Pressure Rating: 2000 W.O.G. Mfr# Desc. Webb# Model T-CS-2000N-SS JOM100-952 1/2” 184958 JOM100-954 3/4” 184951 JOM100-955 1” 184955 JOM100-956 11/4” 184956 JOM100-958 2” 184957
Dimension in Inches
Lever Handle With Side Tap Model T-3100 102-513 1/2” T-3100 IPS 94075 102-514 3/4” T-3100 IPS 94076 102-515 1” T-3100 IPS 94077 102-522 102-523
3/8” Flare X 3/8” Flare 1/2” Flare X 1/2” Flare
94078 94079
Gas Cocks mfr# Size Square Head 10584-12 1/2” 10584-34 3/4” 10584-1 1” 10584-114 11/4” 10584-112 11/2” 10584-2 2”
c
d CV**
1/4”
2.07
0.37
1.76
4.33
6.8
webb#
3/8”
2.07
0.37
1.76
4.33
6.8
437 438 439 440 441 442
1/2”
2.34
0.50
1.92
4.33
9.8
3/4”
2.80
0.69
2.40
5.83
25
1”
3.23
0.87
2.56
5.83
35
11/4”
3.57
1.00
2.74
7.76
47
11/2”
4.04
1.25
2.98
7.76
81
2”
4.63
1.50
3.17
7.76
105
mfr# description webb# Lock Head VCTS80E41 3/4” Locking Meter Valve 250084 VCTS80F41 1” Locking Meter Valve 250085
128
size a b
F.W. Webb Company
** The CV Factor is the gallons of water per minute passed through the valve with 1 PSI pressure drop.
www.fwwebb.com
SECTION
9
Nozzles
Hago Oil Burner Nozzle Series The Webb Part Number is the nozzle gal size, spray angle, and spray pattern, preceeded by HAG. Example: Spray Pattern
Hago 1.00 – 80H
is
Webb Number HAG100-80H
description spray angle flow rate range
“H” - HOLLOW CONE - RED CAPS This series distributes the atomized oil particles evenly toward the outside of the spray cone. These nozzles are particularly well suited for low firing rates and burners with a hollow air pattern. Normally used in wider spray angles.
30° 45° 60° 70° 80° 90°
.65 - 9.00 GP .40 - 9.00 GPH .40 - 9.00 GPH .40 - 9.00 GPH .40 - 9.00 GPH .50 - 9.00 GPH
“S-S” - SEMI SOLID CONE - BLUE CAPS Most suitable for general applications where exact air pattern or spray pattern requirements can’t be established. Droplet distribution is relatively even across spray cone in smaller flow rates, but becomes more hollow as flow rates increase.
30° 45° 60° 70° 80° 90°
.65 - 20.00 GPH .40 - 35.00 GPH .40 - 35.00 GPH .40 - 35.00 GPH .40 - 35.00 GPH .50 - 20.00 GPH
“B” - SOLID CONE - BLACK CAPS Designed to give optimum combustion efficiency on high static pressure flame retention burners which specify a “B” pattern. As compared to our “ES” pattern, somewhat more fuel is concentrated towards the center of the spray.
30° 45° 60° 70° 80° 90°
.40 - 2.00 GPH .40 - 2.00 GPH .40 - 2.00 GPH .40 - 2.00 GPH .40 - 2.00 GPH .40 - 2.00 GPH
“ES” - SOLID CONE - GREEN CAPS Our original solid cone series for low flow rates. Available for applications specifying a solid “ES” pattern.
30° 45° 60° 70° 80°
.40 - 1.75 GPH .40 - 1.75 GPH .40 - 1.75 GPH .40 - 1.75 GPH .40 - 1.75 GPH
“P” - SOLID CONE - GREEN CAPS The “P” type is an extension of our “B” and “ES” series for firing rates of 2.00 GPH and above. It produces a solid cone pattern in the low rates and becomes more hollow as the flow rate increases. Specially designed with a pocketed disc to reduce combustion noises and pulsation.
30° 45° 60° 70° 80°
2.00 - 15.00 GPH 2.00 - 35.00 GPH 2.00 - 35.00 GPH 2.00 - 35.00 GPH 2.00 - 35.00 GPH
“DFN” - DUAL FILTRATION - YELLOW CAPS Available in hollow (DFN-H) and solid cone (DFN-B) patterns, the DFN nozzles give enhanced protection against clogging in the very low flow rates.
45° 60° 70° 80°
.30 - 1.00 GPH .30 - 1.00 GPH .30 - 1.00 GPH .30 - 1.00 GPH
The F.W. Webb Heating Catalog
9_Nozzles_p133.indd 129
F.W. Webb Company
9 Nozzles
129 3/24/08 12:22:42 PM
Nozzles Oil Burner Nozzle Series (cont.) Technical Information FLOW RATING FLOW RATES IN USGPH @ 100 psi 125 140 150 175 200 250 300 GPH psi psi psi psi psi psi psi 0.34
0.35
0.37
0.40
0.42
0.47
0.52
0.35
0.39
0.41
0.43
0.46
0.49
0.55
0.61
0.40
0.45
0.47
0.49
0.53
0.57
0.63
0.69
0.45
0.50
0.53
0.55
0.60
0.64
0.71
0.78
0.50
0.56
0.59
0.61
0.66
0.71
0.79
0.87
0.60
0.67
0.71
0.73
0.79
0.85
0.95
1.04
0.65
0.73
0.77
0.80
0.86
0.92
1.03
1.13
0.70
0.78
0.83
0.86
0.93
0.99
1.11
1.21
0.75
0.84
0.89
0.92
0.99
1.06
1.19
1.30
0.85
0.95
1.01
1.04
1.12
1.20
1.34
1.47
0.90
1.01
1.06
1.10
1.19
1.27
1.42
1.56
1.00
1.12
1.18
1.22
1.32
1.41
1.58
1.73
1.10
1.23
1.30
1.35
1.46
1.56
1.74
1.91
1.20
1.34
1.42
1.47
1.59
1.70
1.90
2.08
1.25
1.40
1.48
1.53
1.65
1.77
1.98
2.17
1.35
1.51
1.60
1.65
1.79
1.91
2.13
2.34
1.50
1.68
1.77
1.84
1.98
2.12
2.37
2.60
1.65
1.84
1.95
2.02
2.18
2.33
2.61
2.86
1.75
1.96
2.07
2.14
2.32
2.47
2.77
3.03
2.00
2.24
2.37
2.45
2.65
2.83
3.16
3.46
2.25
2.52
2.66
2.76
2.98
3.18
3.56
3.90
2.50
2.80
2.96
3.06
3.31
3.54
3.95
4.33
2.75
3.07
3.25
3.37
3.64
3.89
4.35
4.76
3.00
3.35
3.55
3.67
3.97
4.24
4.74
5.20
3.25
3.63
3.85
3.98
4.30
4.60
5.14
5.63
3.50
3.91
4.14
4.29
4.63
4.95
5.53
6.06
3.75
4.19
4.44
4.59
4.96
5.30
5.93
6.50
4.00
4.47
4.73
4.90
5.29
5.66
6.32
6.93
4.25
4.75
5.03
5.21
5.62
6.01
6.72
7.36
4.50
5.03
5.32
5.51
5.95
6.36
7.11
7.79
5.00
5.59
5.92
6.12
6.61
7.07
7.91
8.66
5.50
6.15
6.51
6.74
7.28
7.78
8.70
9.53
6.00
6.71
7.10
7.35
7.94
8.49
9.49
10.39
6.50
7.27
7.69
7.96
8.60
9.19
10.28
11.26
7.00
7.83
8.28
8.57
9.26
9.90
11.07
12.12
7.50
8.39
8.87
9.19
9.92
10.61
11.86
12.99
8.00
8.94
9.47
9.80
10.58
11.31
12.65
13.86
8.50
9.50
10.06
10.41
11.24
12.02
13.44
14.72
9.00
10.06
10.65
11.02
11.91
12.73
14.23
15.59
9.50
10.62
11.24
11.64
12.57
13.43
15.02
16.45
130 9_Nozzles_p133.indd 130-131
F.W. Webb Company
SECTION
9
9
Nozzles Oil Burner Nozzles
Brand Interchange HAGO DELAVAN MONARCH DANFOSS STEINEN NS H H 50 - 2.0 40 - 2.25 Hollow A H .40 - 9.0 .40 - 8.50 .40 - 3.00 Red Caps PL PH 2.25 - 8.5 2.50 - 8.5 Q S-S .50 - 3.00 Semi-solid W AR B .40 - 35.0 .40 - 8.0 .50 - 2.00 .60 - 35.00 Blue Caps SS 4.50 - 28.0 B Solid B R S S .40 - 2.0 .40 - 2.00 .40 - 2.00 .60 - 2.00 .40 - 2.00 Black Caps P Solid B PLP S S 2.0 - 35.0 2.00 - 35.0 2.25 - 35.0 . 40 - 3.00 2.00 - 4.00 Green Caps
The Webb Part Number is the nozzle gal size, spray angle, and spray pattern, preceeded by NOZ. Example: Delavan Webb Number 1.00 – 80H is NOZ100-80H
Available Oil Burner Nozzle Sizes Del-o-flow type a & B
Type A or Del-O-Flo A Hollow Cone (Creates stable flame at low flows)
NOTICE: The Interchanges shown above are “Rule of Thumb” recommendations only. Combustion tests must be made on every installation to assure proper performance. Burner manufacturer’s recommendations should always be followed.
Pressure vs Flow For general purposes, change in flow rate due to change in pressure can be estimated as being approximately equal to the square root of the pressure ratio. TIP: Another way to describe the relationship of pressure vs flow is to remember that in order to double the nozzle flow, you would have to quadruple the line pressure. Simpler yet — contact us for one of our handy Pressure vs Flow Pocket Calculators at no charge.
Type B or Del-O-Flo B Solid Cone (for large burners & where air pattern is heavy in the center or for long fires)
Type W (Can be used in place of A or B Types in reducing specific problems)
GPH .40 .50 .55 .60 .65 .70 .75 .80 .85 .90 1.00 1.10 1.20 1.25 1.35 1.50 1.65 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 8.50 9.00 10.00
45°
60°
70°
80°
TYPE W 90°
GPH .40 .50 .55 .60 .65 .70 .75 .80 .85
The F.W. Webb Heating Catalog
GPH .40 .50 .55 .60 .65 .70 .75 .80 .85 .90 1.00 1.10 1.20 1.25 1.35 1.50 1.65 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 4.00 4.50 5.00
30°
GPH .50 .55 .60 .65 .70 .75 .80 .85 .90 1.00 1.10 1.20 1.25 1.35 1.50 1.65 1.75 2.00
45°
45°
60°
70°
80°
80°
90°
90°
TYPE ss
Del-o-flow type a & B
Type SS Semi Solid (Designed to work where type B’s may be too solid; interchanges well with other SS types) www.fwwebb.com
30°
45°
60°
70°
80°
90°
60°
70°
9 Nozzles
0.30
SECTION
LEGEND Normally Stocked Special Order Limited Inventory Not Available
F.W. Webb Company
131 3/24/08 12:22:43 PM
Nozzles Oil Burner Nozzles
SECTION
SECTION
9
9
Nozzles Nozzles Accessories
(cont.)
Telescoping Mirrors
Burner/Nozzle Selection Nozzle Interchange Chart
Manufacturer
spray angles 30° – 90° Hago/Sid Harvey H SS (up to 2.0) SS (over 2.0) ES/P B Monarch NS/PL R/AR (up to 2.0) R/AR (Over 2.0) PLP Danfoss AS AH
Delavan A SS A or W B B Delavan A R-D/AR/D A/A or W B Delavan W or B A
Use Delavan’s line filter for extra filtration in burner applications of 2.00 GPH or less. These offer four times the filtering area of a standard nozzle stainer and twice the protection. A plugged line filter can cause a pressure drop. Check the pressure on the outlet side of the filter while the unit is flowing to see that it is the same as the pump pressure. If less, replace filter.
Aero Burner
R. W. Beckett
model F-AFC HF-US HF-AFC SV-SSV AF/FG (F) AF/AFG (M) AFII (FB) AFII (HLX) 99 FRD (Std.) 100 CRD (Std.)
The Carlin Co. Elite EZ-1 Elite (EZ-2,3) Mectron 3M 5M Riello Burners
Intertherm
Wayne Home Equipment
Weil McLain
F3, F5 F10 F15, %20 R35.3, R35.5 Press Series MAC 1265 MSH 066 MSH 066 P100 EHASR MSR HS HS EG1 QB180 (150 PSI) QB300 (140 PSI)
80 W, A or B 80 W, A or B 80 W, A or B 70 or 80 B 60, 70 or 80 A or B (100-150 PSI) 60 or 70 A or B (100-150 PSI) 45, 60 or 70 A, W or B (140-200 PSI) 45, 60 or 70 A, W or B (140-200 PSI) .50 - .75 GPH 60 A .85 - 2.25 GPH 45 A, 60 A or B .50 - .75 GPH 60 A .85 - 2.25 GPH 45 A, 60, A or B .75 - 1.10 GPH 60 .50 - 1.00 GPH 70 A .50 - .85 GPH 60 SS .100 - 1.65 GPH 60 or 70 All Flow Rates 60 A, B or SS 60 W, B or Del-O-Flo A (Up to .85 GPH) .40 - 1.25 GPH 60 or 80, W or A 1.25 - 2.50 GPH 60 or W or B 2.00 - 5l00 GPH 45 or 60, W or B .50 - 1.25 GPH 60 or 45, B or W 2.00 - 12.00 GPH 60 or 45, B or W P/N 6601-181 or .55 GPH 90 W .50 - 80 A .65 - 80 A .50 - 1.00 GPH 60, 70 or 80, A or B .75 - 3.00 GPH 80, 70, or 60 ** .75 - 2.75 GPH 80, 70, or 60 ** .50 - 2.50 GPH 80, 70, or 60 ** .50 - 3.00 GPH 80, 70, or 60 B .50 - 3.00 GPH 80, 70, or 60 ** .55 - 1.80 GPH 45, 60, 70, 80 A or B 1.75 - 3.00 GPH 45, 60, 70, 80 B
Nozzle Adapters Long (Female) Standard (Female)
Mirror Parts Telescoping Mirrors
MFR#
DESCRIPTION
12269
Rectangular Mirror Head Assembly
12672 13148
Round Mirror Head Assembly Swivel Bracket Assembly
110 Nozzle Box
MFR#
DESCRIPTION
33175 12640 12275
Mini Mirror With Handle Round Mirror With Handle Rectangular Mirror With Handle
9_Nozzles_p133.indd 132-133
WEBB# 42211 42210 42209
Delavan nozzle boxes handle all brands of nozzle vials. Our 110-nozzle and 55-nozzle boxes are made up of heavy-gauge steel with rugged hinges and snap-latch construction finished in baked-on jet black enamel.
55 Nozzle Box
mfr# description webb# 26846-4 110 Nozzle Box – (5” X 35/8” X 1115/16”) 42207 26846-5 55 Nozzle Box – (5” X 13/4” X 1115/16”) 42206
Hago Nozzle Box 37011
55 Nozzle Box
269290
Other nozzle brands available.
thread size
part #
Webb#
1/8”
28738-1
249791
1/8”
28737-7
69633
9 F. W. Webb with WebbConnect™ allows you to: . figure jobs WebbConnect® . get pricing . order material 24 hours a day / 7 days a week!
mfr# description webb# 34478 Nozzle Changer 42208
F.W. Webb Company
249795 249792
Nozzle Boxes
Delavan’s versatile nozzle changer passes through the small openings of the flame retention-disc. Just snap off outer socket and use the inner socket alone to remove the nozzle. For wider openings, snap on outer socket and use like a standard nozzle changer. The nozzle changer fits the hex of the adapter (3/4”), and the nozzle hex (9/16”).
132
69634
Complete Mirror Assemblies
Nozzle Changer: Two in One
Nozzle Changer
WEBB#
Nozzles
Nozzle Adapter
All nozzle adpaters are med of brass, with precision machined mating surfaces for proper sealing. IMPORTANT specialty 1/2” or 1/4” pipe thread size. All nozzle adapters 9/16-24 UNEF internal thread
Three types of flame inspection mirrors are available. . . the round (33/4” dia.), the rectangular (115/16 X 33/4”) or mini (11/8 X 3”). They are furnished with handles, which telescope down to fit into a service technician’s kit. A cloth bag is provided to protect the mirror finish.
delavan nozzle
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
133 3/24/08 12:22:45 PM
Oil Heating
SECTION
SECTION
10
10
Oil Heating
Oil Burners
Oil Burner Replacement Parts & Accessories
Model AFG The Model AFG oil burner retains the familiar chassis, air tubes and controls found in the popular Model AF, but has an air turbo injector and a high efficiency blower wheel for high static pressure firing under most draft conditions. It is ideal for firing positive pressure heating appliances as well as for overcoming poor draft conditions. Specifications: Capacities 0.40 to 3.00 gallons per hour 56,000 to 420,000 BTU/hr. input
Replacement Parts & Accessories
Air Tube Combinations
Standard Pedestal
Model SF B2007 Chassis
The model SF offers fuel efficiency over a broad firing range. A one-piece flame retention burner head assures a highly efficient flame. This clean, hot flame is virtually unaffected by poor chimney or draft conditions. Specifications: Capacities 1.25 to 5.50 gallons per hour 175,000 to 770,000 BTU/hr. input mfr
description
webb#
Model AFG Chassis (With PSC motor, Ignitor & Suntec A Pump unless noted) B2007 Beckett Clean-Cut pump, R7184B-1032 interrupted, pre-purge B2009
With C554A cad cell, electrical box (no primary control)
Model SF Chassis (With Ignitor & Suntec A Pump) B711 R7184A-1075 interrupted, Beckett F84 valve
34984 119304 1715
F.W. Webb stocks:
134 10_Oil Heating_p155.indd 134-135
F.W. Webb Company
www.fwwebb.com
Adjustable Split Flange Burner Cover
mfr#
description
Air Tubes AF35
webb#
35/8” Less Head for AF/AFG/SR
109060
AF44
41/2” Less Head for AF/AFG/SR
70068
AF53
55/8” Less Head for AF/AFG/SR
75935
AF65
65/8” Less Head for AF/AFG/SR
70069
AF72
71/4” Less Head for AF/AFG/SR
70070
AF90
9” Less Head for AF/AFG/SR
70071
AF104
101/2” Less Head for AF/AFG/SR
70072
AF130
13” Less Head for AF/AFG/SR
AF160
Nozzle Line Oil Heater
Outside Air Intake
Junction Box
mfr#
description
70073
3616
Universal Flange Gasket
16” Less Head for AF/AFG/SR
70074
5432
Adjustable Mounting Flange
AF 30X2T
Burner Tube For Miller
74838
5850
Adjustable Split Flange
70076
585101
LSI Air Tube Combo
256881
5606
Extended Pedestal Kit
1724
5685
Standard Pedestal
1722
mfr#
description
3666
A&S Bulkhead Locknut Fitting
571801
Bulkhead Fitting
51621
Nozzle Line Oil Heater
51747
Ouside Air Intake
51814U
AF/AFG Burner Cover
5770
Junction Box Mounting Kit
firing rate
webb#
webb# 58219 1721
69611
Air Tubes with Head SF65FT 65/8” for SF
2.50 – 5.50
1717
SF65FT
2.50 – 5.50
1718
Burner Heads F0 For AF/AFG/SR
0.40 – 0.75
1797
F3
For AF/AFG/SR
0.75 – 1.25
1798
F4
For AF/AFG
0.85 – 1.35
154497
5880
Low Fire Baffle
70080
F6
For AF/AFG/SR
0.85 – 1.65
1799
5394
8” Tube Connector Assy
70077
F12
For AF/AFG/SF/SR
1.10 – 2.00
1800
51483
Fire Pin Screw Stop
151839
F22
For AF/AFG/SF/SR
1.65 – 2.50
1801
213U
Nozzle Adapter
154063
F31
For AF/AFG
2.50 – 3.00
1802
31231U
Air Guide
215542
F37
For AF/AFG
2.25 – 3.00
1811
3384
33/8 Static Disc
245753
51360
F3 With Porc Ring
112185
51785U
NX6 Slot
368849
NLH90LC
NX Draw Assy
378118
51815U
NX9 Slot
368848
51811U
NX Electrode (Pk 2)
368850
71/4” for SF
The F.W. Webb Heating Catalog
F.W. Webb Company
95780 119305 69607 245955
10
1741
OIL HEATING
boilers!
Extended Pedestal
Air Tube Combinations
135 3/23/08 9:40:24 PM
Oil Heating
SECTION
SECTION
10
10
Riello Burners & Burner Parts
EZ Model Oil Burners
40 Series Oil Burners
All Carlin EZ models have a durable, stainless steel end cone design that holds the flame closer to the retention ring while maintaining a cool surface temperature. It delivers a compact flame that burns cleaner, hotter and more efficiently. Combine that with a nozzle line heater to establish combustion quickly, a 14,000-volt solid state ignitor, and a wide selection of advanced control systems, and you’ll have a smooth, clean ignition even under the most severe conditions!
• Efficiency ratings of close to 90%. • 10 second prepurge cycle. • Completely pre-wired for easy installation. mfr# F3 Burner 8511100S F5 Burner 8512100S
rate (Gph) Tube
Output (btuh) SH#
webb#
0.50 – 0.95
6” Long
70,000 – 133,000
620-30
93170
0.75 – 1.75
6” Long
105,000 – 210,000
620-35
83820
mfr#
webb# 246032
EZ-2 With 4100 Ignitor, Cad Cell, 1 Stage Pump 84801 EZ2 Burner With Control
68805
9687605JP
57829
EZ Pro Burner Box With 5” Tube
mfr#
description
3948873
6” F3 Air Tube
Fits F3, BF3 & M3
110885
3948973
6” F5 Air Tube
Fits F5, BF5 & M5
111078
3005885
Universal Flange
Fits F3, 10 & M3, 5, 10
209578
7001029
530 E Primary Control
Fits all 40 Series and Mectron Oil
77625
mfr#
3005843
Burner Motor
Fits F3, 5, 10 & M3, 5, 10
90144
3002280
Cad Cell Eye
Fits all 40 Series and Mectron Oil
90145
3005844
Capacitor
Fits all 40 Series and Mectron Oil
90146
3002279
Oil Valve Coil
Fits all 40 Series and Mectron Oil
90147
3007077
3/8 Crushable Metal Washer
Fits all 40 Series and Mectron Oil
90148
Air Tube and Combustion Head Assemblies — “Carlin Super Tube” with Nozzle Line Heater 78071 5” Air Tube/Head Assembly f/EZ-1 Chassis 78089 7” Air Tube/Head Assembly f/EZ-1 Chassis 78105 9” Air Tube/Head Assembly f/EZ-1 Chassis 78113 11” Air Tube/Head Assembly f/EZ-1 Chassis
57831 57832 57833 57834
3005869
Electrode Porcelain
Fits all 40 Series and Mectron Oil
90149
7001010
Fuel Pump (new)
Fits F3, 10 & M3, 5, 10
90151
84764 84772 84780
68807 68808 68809
7010002
O Ring Pump Cover
Fits all 40 Series and Mectron Oil
90152
3000443
Pump Drive Key
Fits all 40 Series and Mectron Oil
90153
3005856
Mounting Gasket
Fits F3, 10 & M3, 5, 10
90655
3005719
Pump Screen
Fits all 40 Series and Mectron Oil
90656
7001059
Capillary Tube
Fits F5
91101
3006503
Capillary Tube
Fits M3
91103
3006329
Electrode Assembly
Fits F5 & M5
91104
3006330
Electrode Assembly
Fits F3 & M3
91105
3006925
Pump Stem
Fits all 40 Series and Mectron Oil
91106
C7001071 Metric/NPT Pressure Gauge Adapter
Fits all 40 Series and Mectron Oil
91100
3005847
1/4 Female Metric Adapter
Fits all 40 Series and Mectron Oil
197977
3006571
3/8 Male Metric Adapter
Fits all 40 Series and Mectron Oil
197979
3001023
Vacuum Gauge
Fits all 40 Series and Mectron Oil
90760
3001022
Pressure Gauge
Fits all 40 Series and Mectron Oil
90761
7001001
Emergency Service Kit
Fits all 40 Series and Mectron Oil
90762
7001002
Emergency Service Kit L/Motor
Fits all 40 Series and Mectron Oil
90763
2623539
By Pass Plug
New Style
254415
3001162
Primary Gas Control
Fits all 40 Series
153322
3006966
Electrode Support
246332
3007568
Bleeder Fitting
216801
7001026
2 Line Kit
Fits BF5
256110
7001084
Post Purge Control
Fits BF3 & BF5
223829
F.W. Webb Company
webb#
www.fwwebb.com
Carlin Oil Burner Replacement Parts & Accessories description
webb#
5” Air Tube/Head Assembly f/EZ-2 Chassis 7” Air Tube/Head Assembly f/EZ-2 Chassis 9” Air Tube/Head Assembly f/EZ-2 Chassis
Standard Air Tube and Combustion Head Assemblies 20180 5” Standard Air Tube/Head Assembly f/99,100 Chassis 20230 7” Standard Air Tube/Head Assembly f/99,100 Chassis 20313 9” Standard Air Tube/Head Assembly f/99,100 Chassis
2603 2604 2605
Mounting Flange and/or Pedestal 82560S 31/2” Heavy Duty Aluminum Universal Flange/Gasket 23317S EZ-1, 2, 3 – 99,100 Pedestal 97406 Outside Air Inlet Boot, EZ-1
57835 2618 111001
Air Bands 77594S
EZ-1
166967
Air Shutters 77586S EZ-1 83956S EZ-2
166966 166970
Blower Wheels 28530 41/4” OD X 215/16” W, 1/2” Bore, 100 CRD 77933 51/16” OD X 2” W, 1/2” Bore, f/EZ-1,2,3 28605 51/4” OD X 2” W, 1/2” Bore, 99 FRD
2755 149499 152698
Flame Retention Ring Assemblies 54901S f/99 FRD, 100 CRD 77438S f/EZ 1,2,3
54084 149498
Miscellaneous Parts 40287 Flange Gasket f/EZ, 99/100/201/301/601/701 77438S Instant Opening Oil Valve f/EZ-1,2,3 – 99,100, 102 81570S Head Positioning Bar Kit EZ-1 84715S Head Positioning Bar Kit EZ-2 66795S Nozzle Line Heater EZ-1,2,3 – 99,100
2617 149508 149501 149502 75556
The F.W. Webb Heating Catalog
F.W. Webb Company
10 OIL HEATING
10_Oil Heating_p155.indd 136-137
description
EZ-1 With 4100 Ignitor, Cad Cell, 1 Stage Pump 9687600JI EZ1 Burner With Pre-Post Purge Control Less Tube
Oil Burner Replacement Parts & Accessories
136
Oil Heating
137 3/23/08 9:40:37 PM
Oil Heating
SECTION
SECTION
10
10
Electrodes mfr# 123
description Arco Set/2
137C
ABC 41/4” Set/2
Electrodes webb# 69738
69739
144A
A = 41/4” ABC 6” Set/2
69740
146
A = 6” ABC 4” Set/2
222857
151E
151F
mfr# 188P
description Carlin 200 Set/2
webb# 69737
598
Weil McLain Set/2
253181
604
Wayne Set/2
179771
605
Wayne Set/2
151361
605A
Wayne Set/2
75580
605B
Wayne Set/2
74877
605C
Wayne Set/2
75581
605D
Wayne Set/2
77224
28550
Beckett Set/2
Beckett Set/2
246744
151R 151R2
Beckett Set/2, A = 27/16” Beckett Set/2, A = 3”
69741 111220
86341
Carlin Set/2
188N
188N4
Carlin 501 Set/2
Carlin Set/2
Carlin EZ1 Set/2
description 7/16” X 1/8” X 6” Set/2
webb# 119312
2M4 2M6
9/16” X 3/16” X 4” Set/2 9/16” X 3/16” X 6” Set/2
118652 119311
3M4 3M6
9/16” X 1/8” X 4” Set/2 9/16” X 1/8” X 6” Set/2
118654 118656
Wayne Blue Angel Set/2
75583
605I
Wayne Set/2
69735
69736
606
Wayne Set/2
75584
69749
Carlin Set/2
F.W. Webb Company
216131
51484U 51805U 5780 5782
AF II Electrode Kit AF II Electrode Kit AF/AFG Electrode Kit, Thru 9” AF/AFG Electrode Kit, Over 9”
112591 95783 1817 1819
www.fwwebb.com
mfr# Description 144INS ABC 151EINS Beckett 188BINS Carlin 1M4P 7/16” X 1/8” X 4” Male 1M6P 7/16” X 1/8” X 6” Male 2F4P 9/16” X 3/16” X 4” Female 2F6P 9/16” X 3/16” X 6” Female 2M4P 9/16” X 3/16” X 4” Male 2M6P 9/16” x 3/16” X 6” Male 3F6P 9/16” X 1/8” X 6” Female 3M4P 9/16” X 1/8” X 4” Male 3M6P 9/16” X 1/8” X 6” Male 4M4P 1/2” X 1/8” X 4” Male 4M6P 1/2” X 1/8” X 6” Male
webb# 95425 95451 250499 79358 77227 201845 92532 179389 77228 79361 179395 77231 77377 77229
Porcelain Squeeze & Snap Cutter 4M4C
154923
1/2” X 1/8” X 4” Set/2
997 This tool is great for cutting standard gauge glass. It will even cut short pieces of 1/2” long or less. Just set the stop to the length you need, squeeze the “trigger” and rotate the glass until it snaps cleanly in two!
Tune Up Kits
Fits Blue Angel Model HS Contents: 1 J-Pump Coupling End 2 Electrode Assemblies w/Buss Bar 1 Oil Line Assembly 1 Gun Setting Gauge 1 Pump Coupling 1 90° Elbow 1 Electrode Support 1 Buss Bar Support
mfr# 997
description Porcelain Squeeze & Snap Cutter
webb# 55790
Tip Setting Gage In order to avoid Carbon Impingement, ignitor tips must always be placed just outside the nozzle spray pattern. This tip setting gage allows you to accomplish this easily and accurately while at the same time setting the correct spark gap.
Wayne
Carlin
Fits M, MSR, MH, ER, ERA, EH, EHA, EHASR, OE, OEA Contents: 2 Electrode Stems 2 Electrode Assemblies w/Insulator 2 Buss Bars (8”) 2 Insulator Bushings 1 Oil Line Assembly 1 Coupling 1 J-Pump Coupling End 1 90° Elbow 1 Buss Bar Support
For Carlin Elite Burner Contents: 2 Electrode Assemblies 1 12” Oil Line Assembly 1 Red Tip Setting Gauge 1 Yellow Setting Gauge 1 Pump Coupling Kit 1 Instruction Sheet mfr# Type Webb# 31156 Wayne 93026 31157 Blue Angel 93027 CK780 Carlin 162187
The F.W. Webb Heating Catalog
mfr# Description 40445 Tip Setting Gage
webb# 69675
10
Electrode Setting Gauge
OIL HEATING
10_Oil Heating_p155.indd 138-139
605F
Beckett Electrode Kits
A = 81/2”
138
75582
152275
A = 81/2” 188N6
Wayne Set/2
28551
Carlin Set/2
A = 7/8” 188K
mfr# 1M6
Blue Angel 605E
188B
Electrode Porcelains Only
(cont.)
95424
Beckett Set/2
151G
188
Oil Heating
For setting oil burner electrodes at all nozzle spray angles. mfr# 40445 40448 T500 Z2000U
for model webb# All Models 69675 Carlin Elite 241987 Electrode Tee Gauge, Nozzle Head 95837 Tool Setting Electrode 242671
F.W. Webb Company
139 3/23/08 9:40:54 PM
SECTION
SECTION
10
10
Oil Heating
Oil Heating Ignition Cable
Electronic Transformer Kit
17K Electronic Transformers
120 Volt Primary, 50/60 Hz, 17,500 Volt Secondary, 23mA, MPG mfr# 2275 2275U 2275-456 2275-605 2275-619 2275-620 2275-628G 2275-629 2275-630 2275-653
mfr# 2275KIT
description Constant Duty Ignitor Only Ignitor With Universal Plate Aero Ignitor With Base Beckett Ignitor With Base S Wayne Ignitor With Base M Wayne Ignitor With Base E Beckett Ignitor Base AF/AFG Carlin Ignitor 200,201 Carlin Ignitor With Base 99,100 CRD Weil McLain Ignitor With Base QB
webb# 243650 253254 244238 244239 243651 244240 243646 245677 243648 245657
description f/Aero f/Beckett S f/Wayne M f/Wayne E f/Beckett AF/AFG f/Carlin 99,100,101 CRD f/Wayne Blue f/Weil McLain f/Carlin 200,201,500,501 CRD
webb# 244660 250027 243652 250028 243647 243649 245661 245658 245659
Base Plates mfr# 2600 2601 2602 2603 2604 2605 2606 2608 2609
10K Transformers
120 Volt Primary 60 Hz, 10,000 Volt Secondary, 23mA, MPG description webb# Carlin Transformer, 12K Volts 28658 ABC Transformer 69765 Aero Transformer 28663 Nu Way Transformer 69766 Beckett Transformer S 28655 Wayne Transformer M 28661 Wayne Transformer E 28662 Beckett Transformer AF/AFG 28654 Carlin Transformer 200,201, 500, 501 CRD 28657 Carlin Transformer 99, 100, 101 CRD 28656 ABC Sunray Transformer 213520 Wayne Blue Angel Transformer 52694 Beckett AFII Transformer 214061
See page 283 for Cross Reference information.
140 10_Oil Heating_p155.indd 140-141
F.W. Webb Company
description webb# Ignitor Kit 244985
Electronic Transformer Kit Includes: 2 Units, CAT 2275 Electronic Transformer One each of the following mounting plates: 2600 Aero 2601 Beckett S 2604 Backett, A, AF 2605 Carlin 99, 100, 101 2602 Wayne Hi Speed M/MH 2603 Wayne E 2606 Wayne Blue Angel One 54-740 Universal Contact Replacement Kit
Universal Transformers
120 Volt Primary 60 Hz, 10,000 Volt Secondary, 23 mA, MPG mfr# 421-BT290 421-BT332 421-BT636
description Ignition Transformer Ignition Transformer Ignition Transformer
webb# 69769 69771 28660
mfr# description webb# Cad Cell Control/Ignitor 40100-02-BKS 15 sec f/Beckett 71826 40100-02-CAS 15 sec f/Carlin 71827 Constant Duty Ignitor (14K) 41000-S Ignitor Only 75592 41000-SO-BK1 With Base, Beckett AF/AFG 71824 41000-SO-BK2 With Base, Beckett S/SR 215613 41000-SO-SC With Base, Carlin 210,301 194794 41000-SO-CAS With Base, Carlin EZ-1,2,3 –99,100 71825 41000-SO-WA2 With Base, Wayne E 88136 41000-SO-WA1 With Base, Wayne HS 73195 41000-SO-WA3 With Base, Wayne M 88137 41000-SO-WM With Base, Weil McLain 215992 41000-SO-KIT Universal Ignitor Kit 95236 Base Plate Kit 41020-00-AR Aero 94773 41020-00-BK1 Beckett AF/AFG 94768 41020-00-BK1 Beckett S/SR 192261 41020-00-CAS Carlin Residential 94767 41020-00-CSC Carlin Small Commercial 166752 41020-00-WA2E Wayne E 94769 41020-00-WA1 Wayne HS 75591 41020-00-WA3 Wayne M 94770
mfr# Description 251C 25’ Ignition Cable, GTO-15 3P 100’ Ignition Cable, Red Silicone
Buss Bars mfr# DescRIPTION Flat Buss Bars F6 6” Long F12 12” Long Round Buss Bar ST12 12” Long
A
Mini Kit #34 mfr# 51826U 51824U 51825U 51771U 51805U 51837U 51827U 51840U
description Ignitor With Carlin 99/100 Base Ignitor With Beckett S Base Ignitor With Wayne M Base Ignitor With Beckett AF/AFG Base Ignitor With Beckett AF II Base Ignitor With Weil Mclain Base Ignitor With Wayne E Base Ignitor With Carlin 200 Base
webb# 249439 318775 318776 67646 95783 249440 277501 318774
F.W. Webb stocks furnaces! www.fwwebb.com
A small but highly selective assortment of popular RAJAH ignition terminals. 20 Cage terminals 12 Spring snap terminals 20 Ring terminals 10 Right angle terminals 12 Stud ferrule terminals
Transformer Kit #54 An excellent selection of the most used transformer terminals, good variety. 6 Short adapter spring 6 Long adapter spring 2 Thumb nut on cage 2 Spring plunger 4 Button contact, short 2 Button contact, long 6 Cage on cage 6 Ram’s horn on cage 4 Ram’s horn on hex 2 Ram’s horn clip 6 10-32 hollow studs 6 10-32 hex studs mfr# Description 34 Mini 34 Ignition Terminal Kit 54 Transformer Ignition Terminal Kit
The F.W. Webb Heating Catalog
webb# 54595 54596
webb# 69733 55809 151217
Ignitor and Transformer Terminals
Ignition Terminal Kits
Electronic Transformers
webb# 54600 188183
H
O A B C D E F G H I J K L M N O P Q R S
B
I
P mfr# ACT AEBF AS-10 ASN B-10 CC-1 CT CT-TS EBF HS10-32 RX4 S-15 SF SS SS-BS1032 SSN SS-TS YL-10 YS-10
C
D
E
F
J
K
L
M
Q
R
S
description Angle Cage Extended Angle Thermoplastic Short “A” Spring Angle Spring Snap Brass Button Contact Cage on Cage Straight Cage Cage on 10-32 Threaded Screw Extended Thermoplastic Hollow Stud Tapped 10-32 Ram’s Horn on 10-32 Hex Base Beckett Spring Stud Cable Ferrule Spring Snap Cable Terminal Snap Spring 10-32 Hex Base Spring Snap Spring Snap on 10-32 Screw Long “Y” Spring Short “Y” Spring
F.W. Webb Company
G
N
webb# 94196 188184 94193 108982 69746 94200 94197 69744 188185 94202 94201 162186 94187 119310 94189 108532 69745 69723 69724
10 OIL HEATING
mFR# 2714-633 2721-411 2721-456 2721-572 2721-605 2721-619 2721-620 2721-628G 2721-629 2721-630 2721-631A 2721-647 2721-658
14K Electronic Transformers
• 15,000 Volts. • UL listed. • 19 strands of copper wire. • All vinyl insulation for low temperature flexability. • Flame retardant, will not support combustion. • Tested to withstand oil, moisture, salt atmosphere and sunlight. • Large .275 outside diameter for sturdy construction.
141 3/23/08 9:41:43 PM
Oil Heating Fuel Oil Filters 77FW The 77FW is the perfect fuel filter for oil fired heating appliances used in small to average sized homes and commercial buildings. It is ideal for final filtration in central fuel oil distribution systems. The 77FW may be used in one or two-pipe systems. mfr# description webb# 77FW 10 GPH Complete Fuel Oil Filter 259959
99FW The 99FW is perfect for oil fired furnaces in larger homes and commercial buildings. It may be used in one or two-pipe systems. Its large dirt capacity makes the 99FW ideal where heavy contamination of oil causes premature clogging of smaller filters. mfr# description 99FW 24 GPH Complete Fuel Oil Filter
webb# 187636
PurePro 77FW & 99FW Fuel Oil Filter Feature: • Leakproof construction with machined gasket seat and UL listed gasket compounds. • High quality wool felt filter elements that remove all solid contaminants. • Iron nd steel construction for maximum integrity and durability. • Low pressure drop, suitable for gravity flow and one or two pipe systems on pressure type burners. • Micronic filtration suited to the smallest oil burner nozzle. • Bonding treatment of center core in filter element eliminates lint. • Step design element offers largest dirt capacity with true depth filtration. • Listed by Underwriters’ Laboratories.
SECTION
SECTION
10
10
Oil Heating
Spin-on Filters • Epoxy coated and UL Listed. • 1/8” NPT tapping for vacuum gauges and bleeding. • Cast aluminum top. • Seamless one piece canister (drawn steel). • 10 Micron filter media. • Perforated metal center support tube. • Spring pad (no metal to epoxy contact). • Nitrile gasket (prevents swelling) for easy removal of element. mfr# description webb# High Efficiency Filtration F100W Complete, 10”, 17gph, 3/8” NPT 69858 F-100-2W Complete With Bracket 73202 F-100-6W Complete With Bracket & Gauge 265045 F100-14W Color Coded Vacuum Gauge 153602 F100-4W Complete With Vac Gauge 265044 F100-10W Res Filter Element Only 69860 Commercial Duty Filtration F100-1W Complete, 10”, 37gph, 3/8” NPT 265046 F-100-3W Complete With Bracket 265047 F-100-5W Complete With Bracket & 14W Gauge 265048 F100-7W Complete With Bracket & Gauge 265049 F100-11W Spin-on Filter Element Only 85958
Fuel Oil Filter Refill Cartridges 88-CRW & 101W • High quality wool felt filter elements that remove all solid contaminants. • Crafted with special “step design” wool felt. • Step design element offers largest dirt capcity with true depth filtration. • Special center core bond treatment eliminates line. • Micronic filtration suited to the smallest oil burner nozzle. • For models 77FW and 99FW, 1A25, 2A-700A, they offer unsurpassed quality and dependability. mfr#
description
88-CRW
Wool Felt Replacement Cartridge f/77W
101W
Wool Felt Replacement Cartridge f/99W
• Replaces FB4 filter. • Heavy gage canister with EPOXY COATING on the inside – FIRST in the industry! • Listed by Underwriters Laboratories. • UL GPH and pressure ratings EXCEED comparable OEM filters. • 360º screwdriver slot makes disassembly for element changing easy. mfr# description F80-1W Complete 30 GPH
webb# 9830
142 10_Oil Heating_p155.indd 142-143
F.W. Webb Company
mfr#
description
RF-1W
Replacement Cartridge f/77FW, 1A25
RF-2W
Replacement Cartridge f/99FW, 2A-700A
RF-4W
Designed to fit other FB4-style filter brands
for FB3
4FO
w/gasket for FB4
4FOLG
for FB4
73256
6FO
for FB6
69761
8FO
for FB8
69762
10FO
for FB10
76701
69760 9831
Gaskets description Fulflo F84 Cover Gasket
webb#
webb#
F96
Fulflo Vent Screw Gasket
69866
55401
F97
Fulflo Hex Nut Gaskets
69868
G90
1A25A Cover Gasket
69867
GAS
Gasket for FB4/6/8/10
9838
69865
A bucket with a parts strainer tray in the top. The oil serviceman simply places all oil filter cartridges in the strainer tray for 24 hrs. The cartridges may then be disposed as normal trash, since the EPA no longer considers them hazardous waste. mfr#
description
EZCHANGE
Filter Draining System
webb# 190768
webb# 74469 187637 79946
Fuel Oil Filter Replacement Cartridges
10
Made of bonded felted fibers. Replacements for C-40, C-50 and C-60 fuel oil filters.
webb# 9832 55399 9834 9835 9837
www.fwwebb.com
3FO
mfr# description
The F.W. Webb Heating Catalog
OIL HEATING
F.W. Webb Stocks peerless boilers!
webb#
F95
• Crafted from continuous spun Rayon fibers. • Exclusive gear tooth design for maximum surface area. • Enhanced depth filtration. • 16-tooth gear design of the RF-Series rayon elements provides exceptional performance. • The RF-Series has a third more surface area. • The RF-Series has 20% more volume than the competitive product.
For use on domestic or commercial oil burner systems up to 40 gph capacity, with “honeycomb” filter cartridge. description Complete, 15 gph Complete, 20 gph With Bracket Complete, 32 gph Complete, 40 gph Complete, 50gph
description
EZ-Change Filter Draining System
Fulflo Fuel Filters mfr# FB3 FB4B FB6 FB8 FB10
mfr#
mfr#
RF-1W, RF-2W, RF-4W Series
Fuel Oil Filter
Fulflo Filter Elements
webb#
RC20
C40 Repalcement Cartridge
69364
RC30
C50 Repalcement Cartridge
9816
F.W. Webb Company
143 3/23/08 9:42:29 PM
Oil Heating Tiger Loop® Oil De-Aerator One pipe system for all light oil burners. The guarantee for efficient and trouble-free oil heating. • Fewer breakdowns. • Less soot build-up. • Cleaner exhaust gases. • Lower oil consumption. • Easier trouble spotting. • No return line leakage. • Simpler and cheaper installations. • Smaller pipe dimensions. • More burners on one suction line. • Fewer problems with long oil lines. • Longer-lasting oil filter. Max. nozzle capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . 19 gph Max. return oil pumped into the Tigerloop: . . . . . . . 31 gph Max. oil flow: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 gph Max. operating temperature: . . . . . . . . . . . . . . 105°F (40°C) Max. ambient temperature: . . . . . . . . . . . . . . . 105°F (40°C) Operating pressure in feed line: . . . . . . . . . . . . . . Max. 10 psi Pressure test of pipe system: . . . . . . . . . . . . . . . . . Max. 85 psi Pump and tank connections: . . . . . . . . . . . . 1/4” inner thread mfr# DescRIPTION webb# S220 Tigerloop 69674 S220-8W Tigerloop With Spin on Filter 318508
Steel Flexible Braided Hose These hoses have 1/4” NPT fittings on both ends. Made from Nitrate rubber (inside), which is impervious to oil, water and air, plus a steel braided outer casing, for strength and flexibility. mfr# size webb# S220-24 24” 91056 S220-36 36” 91057 S222-36W 3/8” Flex SS Oil Line 92069
Oil Lines Soft annealed copper tubing in both 3/16” and 1/4” OD sizes. Assembled with machined brass flared fittings. Tubing is supplied straight unless specified. description webb# 3/16” X 5” 72190 3/16” X 8” 179387 3/16” X 12” 55798 3/16” X 16” Coil 69672 1/4” X 16” Coil 69673 1/4” X 12” 55797 Connector Tube Assembly 70077 61/2” Jet Line 91131
144 10_Oil Heating_p155.indd 144-145
F.W. Webb Company
SECTION
10
10 Suntec Pumps
Handpump A combination pressures and vacuum Handpump for air or liquids — to clean lines, free stuck valves, prime pumps, build up test pressure or vacuum in lines and tanks. Handpump Assembly mfr# T30W T30-4W T30-6W
description Webb# Handpump 253699 Quick Con Kit 308436 Carry Case 308437
CO2 Blowout Gun The Blowout Gun is ideal for cleaning out clogged instrument transmission lines and other lines where no automatic means for blowing out is available. The Blowout Gun uses CO2 cartridges and incorporates a 1/4” female connection that can be adapted to any fitting. It is completely safe for all petroleum products. For use with other liquids it is best to check with the supplier of the liquid. mfr# T32-W
description CO2 Blowout Gun
webb# 55801
V4046A, B For ON-OFF control of oil flow to domestic oil burner equipment. • Power interruption closes the valve immediately. • Mount directly to pipeline or on support bracket. webb# 31373 31374
webb# 55297 247220
Anti Hum mfr 518
description Silent Flo Anti Hum Devise
Model A1, A2 Mini Pumps
J & H Pumps
mfr# DESCRIPTION WEBB# S70 Suntec New Style Mini Pump Gasket 204569 S190-7 Suntec New Style Mini Pump Gasket (10 pk) 259936 S71 Suntec H/J/K Pump Gasket 70053 S150-55 Suntec H/J/K Pump Gasket (10 pk) 259935 S72 Suntec S1/S2/R3/R4 Pump Gasket 70055 S75 Suntec Mini Pump Gasket 70052 W83 Webster M Pump Gasket 69864
Bleeders mfr# DESCRIPTION WEBB# SP335 1/8 Pump Bleeder 246500 SP336 1/4 Pump Bleeder 246501 SP337 Suntec Mini/J/H Pump Bleeder 69862
By Pass Plugs mfr# DESCRIPTION WEBB# SP351 Suntec 1/16 A & B Mini Pump By Pass Plug 68283 SP352 Suntec 1/8 J/H/K Mini Pump By Pass Plug 69863
Strainers
Oil Valve Kit mfr description 5669 Delay Oil Valve Kit 2182602U Delay Oil Valve Kit — Solid State
mfr# description webb# Booster Pumps BB-1020M 15 GPH, Complete 47077 BB-1030M 30 GPH, Complete 47078 Mini Pumps A2VA-7116 1 Stage 3450, 3 GPH, CW-R 70060 B2VA-8216 2 Stage 3450, 3 GPH, CW-R 70061 A1VA-7112 1 Stage 1725, 3 GPH, CW-R 70062 A2VA-3006 1 Stage 3450, With Solenoid 3 GPH, CW-R 252037 A2YA-7916 1 Stage 3450, 7 GPH, CW-R 70063 J Pumps J3BA-100 1 Stage 1725, CW-R 70064 J3BB-100 1 Stage 1725, CW-L 70065 JJ2BB-100 1 Stage 3450, CW-L 70266 H Pumps H3BA-100 2 Stage 1725, CW-R 70066 H3BB-100 2 Stage 1725, CW-L 70067 Accessories 3753895 Non Delay Cord Set 252038 3753898 Delay Cord Set 252039 3713824 Oil Valve 244411 PRV-38 3/8 Oil Safety Valve 52760
Gaskets
Magnetic Valves
Operating Valve mfr# Pressure Opening Time V4046A1074 300 psi 3 sec. to 8 sec. V4046B1049 300 psi Immediate
Oil Heating
webb# 1742
www.fwwebb.com
mfr# DESCRIPTION WEBB# 135721HK Suntec J & H Pump Strainer 70054 3715732HK Suntec 1 Stage Mini Pump Strainer 69861 SSC110 Suntec 2 Stage Mini Pump Stainer 152804 SSC111 Suntec A & B Mini Pump Stainerw/High Cover 73255 SSC126G Riello Strainer With O-Ring 118986 SSC127 Danfoss New Style Pump Strainer 150483 SSC128 Danfoss Old Style Pump Strainer 150484
The F.W. Webb Heating Catalog
Mini Pumps Automatic By-Pass: No plug required for piping conversion. Bleed/Return Plug: Full flow rate when open. Closing or restriction of return line will not cause overpressure or overfire. Patented Shaft Seal: Mechanical type carbon and steel guaranteed to 30 psi inlet pressure. Trochoidal Gear Set: 15 GPH flow rate. Less friction loss on 2 line systems and reduced rumming vacuum. Closer tolerances for quiet operation. Lower operating torque with guaranteed curves. High Lift Capacity: Guaranteed 14’ – 2 line system. Nozzle Pressure: Adjustable to 210 psi at 3450 RPM – steady setting. Easy Maintenance: Loosen 2 screws and twist off cover. O-ring stays in place (best seal against leaks.) mfr#
description WEBB#
071N1151 071N1152
3450 RPM RH Rotation Direction RH Nozzle Port Location 1725 RPM RH Rotation Direction RH Nozzle Port Location
88331 70279
CleanCut Fuel Pump The Beckett CleanCut Pump uses a solenoid valve, rather than the diaphragm and cone valves used in conventional pumps. Solenoid valves open and close instantly when electrical current to the pump turns on and off. This provides higher-pressure cut-ons and cut-offs— for cleaner, more efficient burner operation. And since there are fewer moving parts, there are fewer potential problems. mfr 21844U 21887U
description Clean Cut Fuel Pump With Solenoid Valve PD Timer Pk
F.W. Webb Company
webb# 246748 264286
10 OIL HEATING
mfr# S213-5 3608 S213-12 S213-16 S214-16 S214-12 5394 5636
SECTION
145 3/23/08 9:43:03 PM
Oil Heating Oil Burner Couplings & Accessories mfr# KK100 KK120 KK112
description Pioneer 3 Pc. Kit (Carded) Pioneer 5 Pc. Kit (Carded) Pioneer 12 Pc. Kit
SECTION
SECTION
10
10
Burner Blower Wheels webb# 178208 224702 69658
mfr# 21438U 21439U 2288 2459U 2999U
description AF II 150 Burner Wheel AF II 85 Burner Wheel SF Burner Wheel AF Burner Wheel AFG Burner Wheel
Oil Heating
Lynn Products Instant-Glo “Quickie”
webb# 152235 95779 216421 69608 69609
mfr# 1001 1002 1003 1004
model# firinG rate 100 .75 – 1.25 gph 200 1.35 – 1.75 gph 300 1.75 – 2.25 gph 1004 .65 – 1.00 gph
dimensions 111/2”W X 11”L X 103/4”H 12”W X 133/4”L X 12”H 12”W X 18”L X 12”H 11”W X 101/4”L X 101/4”H
webb# 12407 12408 12409 69782
Quick Chamber
Instant-Glo Timesaver Made from Vac-cast Kaowool, 3/4” or 1” wall thickness and floor with stainless steel straps. S85-500W S85-510W
mfr# 1009 1011 1013
154484 54598
Nylo-Flex #88 4 Pc. Kit Nylo-Flex 99A 6 Pc. Kit
model# #9 #11 #13
firinG rate .65 – .85 gph 1.00 – 1.25 gph 1.35 – 1.75 gph
dimensions webb# 9”ID X 101/2”OD X 143/4”H 68999 11”ID X 121/2”OD X 151/2”H 12410 13”ID X 141/2”OD X 16”H 12411
Instant-Glo Timesaver
Kaowool Rope Excellent as gasket material or as an alternative to asbestos rope. 25’ length of rope packaged in plastic bag. S85-200W 21437U S85-220W 12CP CPNYL30 516RD 716BLU 12BLK
Beckett AF/AFG 313/32 Beckett AFII Carlin 99/100/101 23/8 12” Nylo-Flex Coupling Shaft 30” Nylo-Flex Coupling Shaft Nylo 5/16 Red Fitting End Nylo 7/16 Blue Fitting End Nylo 1/2 Black Fitting End
12” Coupling Shaft 35
mfr# Temp. Limit 9400 1000° F 9401 1000° F 9404 1000° F
28556 95778 28555 68441 88088 68438 68439 68440
Kaowool Dry Blanket Kaowool Rope
Soft fiber blanket — can be formed at shape of existing chamber. mfr# Temp. Limit 9449 2300° F 9450 2300° F 9451 2300° F
description webb# 48” X 18” X 1” 69793 56” X 14” X 3/4” 69149 48” X 16” X 1/2” 69150
Kaowool Dry Blanket
Nylo End Fittings
Coupling Cutter
description webb# 3/8” X 25’ 69784 1/2” X 25’ 69785 1/4” X 25’ 112594
Kaowool Strip
74876
Excellent as gasket material or as an alternative to asbestos rope. Packaged in master cartons of 6 pcs. per ctn.
Coupling Cutter Kaowool Strip
mfr# 9500 9501 9506
description 150” X 2” X 1” 300” X 1” X 1/4” 300” X 1” X 1/2”
webb# 77985 77986 77987
10 OIL HEATING
Kaowool Board Can be used as target wall, floor, burner block and many more applications.
F.W. Webb stocks airco furnaces!
mfr# 1019 1022 1023 1025
description 20” X 20” X 1” 15” X 24” X 3/4” 20” X 20” X 3/4” 36” X 18” X 1/2”
webb# 12418 12417 217172 12420
Kaowool Board
146 10_Oil Heating_p155.indd 146-147
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
147 3/23/08 9:44:54 PM
Oil Heating Lynn Products
SECTION
SECTION
10
10
Oil Heating
Lynn Products
(cont.) Kaowool Wet Blanket Soft, moist fiber blanket that can be formed to shape of existing chamber as a liner.
Kaowool Wet Blanket
mfr# 1032 1033 1034
model# description Kit A (1) 14” X 48” X 1/2” Kit B (1) 14” X 48” X 1/2” & (1) 16” X 16” X 1/2” Kit C (1) 16” X 48” X 1/2” & (1) 16” X 16” X 1/2”
(cont.) Full Brick — Insulating Firebrick (25 per carton) mfr# K23
webb# 12414 12415 12416
description 2000°F — for chambers 1. to 2.5 gph
size 9” X 41/2” X 21/2”
webb# 12422
size 9” X 41/2” X 11/4”
webb# 69792
Split Brick — Insulating Firebrick (45 per carton) mfr# 5075
description 2000°F — for chambers 1. to 2.5 gph
Kaowool Cement Wet Combustion Chamber
mfr# 5601
The strongest wet from combustion chamber in the industry. Round chamber with bottom — thickness 1/2” minimum.
Wet Chamber
mfr# 1038 1039 1040 1041
firinG rate .65 – .85 gph .85 – 1.00 gph 1.00 – 1.25 gph 1.25 – 1.50 gph
dimensions 9” Inside X 15”H 10” Inside X 15”H 11” Inside X 15”H 12” Inside X 15”H
webb# 69786
Burner Head Protector
Gaskets for Miller-Gun Mobile Home Furnace mfr# Model#
description Size
9510 Gasket Kit for Miller
Kit contains one each of the following: #3001-000 Burner Gasket #301195-000 Flue Gasket #301181-000 Pouch Gasket #301205-000 Burner Plate Gasket
73812
9511
#3001-000
Burner Gasket (20 pcs. per pkg.)
61/2”OD X 43/8”ID
76584
9514
#301195-000
Flue Gasket (20 pcs. per pkg.)
71/16”OD X 51/8”ID
76583
9512
#301181-000
Pouch Gasket (20 pcs. per pkg.)
10” X 131/2”
76585
9513
#301205-000
Burner Plate Gasket (20 pcs. per pkg.)
101/4” X 16”
76586
webb#
Weil McLain Clamber Kit
description Clean out cover gaskets (20 pcs. per pkg.)
size 3”OD X 2”ID
mfr# model# description Burnham V1, V3, & V7 Series Boilers 1064 V1 Series Wet moldable rear refractory 1065 V3 Series Ceramic fiber blanket “Base liner” 1066 V7 Series H.B. Smith Model FD-12 1068 F12 Chamber Kit Miller Mobile Home Furnace 1029 Fits Models: CMF, MOC & MGC Peerless Wet-Base Boilers 1067 Fits Models: JO/JOT 1071 Fits Models: WB, WV, WBV 1073 Ultimate PFD 1093 Peerless EC 1074 Burnham V7 w/Swing Door Utica Starfire II 1095 Utica Starfire III 1096 Weil-McLain 1060 Fits models: 66,68/68V Weil-McLain – Gold 1072 Fits models: WG/WGO
webb# 154091 223347 154092 246331 12421 94008 112637 252724 221718 310463 155218 251773 71970 151283
Oil Absorber Mat For repairing and installing burners, pumps, oil lines, nozzles, filters, etc. These mats will easily absorb the oil that may be released during this service work and are conveniently folded and disposed of after the work is complete.
Gaskets for Duomatic Furnace mfr# 9515
webb# 69151
Replacement Combustion Chamber Kits
webb# 249185 69787 69788 69789
Burner Head Protector mfr# description 1030 Fits 4” OD Burner Heads (Beckett)
description Waterglass Adhesive For Kaowool (1 quart)
mfr# 8055
webb# 178699
description size Bale of 100 18” X 18” X 1/4”
webb# 86306
10
Vermiculite
148 10_Oil Heating_p155.indd 148-149
F.W. Webb Company
www.fwwebb.com
mfr# Vermiculite 1 Water Glass WTRGLASS
The F.W. Webb Heating Catalog
description
OIL HEATING
Colco webb#
4’ Cubic Bag
69664
1 Quart Can
69663
F.W. Webb Company
149 3/23/08 9:44:57 PM
Oil Heating
SECTION
SECTION
10
10
Domestic Oil Tanks
Oil Heating The safest most reliable tank you can buy. They are a logical and responsible choice.
80 UL • Welded lap joint. • Ergonomic handle on each head for easy handling. Outside Finish • Preparation: Washed and Phosphered. • Electrostatic powder paint, Black. Technical Specifications • Steel ASTM A-569. • Tested at pressure 5 to 7 PSIG. • UL 80 Label.
• 100% Safe. ECOGARD double bottom system with leak detection system. • Environment Friendly. Responds to environmental concerns and requirements. • Guaranteed Durability. Polyurethane coating for external protection on PROTEC20. • Warranties: Up to a 25-year warranty and 2 million dollars in liability insurance coverage. • Peace of Mind. With 50+ years of experience, Granby Tanks is known for its quality and proven track record in innovation and design.
Dimensions Mfr#
#products
models
H
W
L
209101
120, US gals. Vertical
47”
23”
30”
12 ga
170 lbs.
88334
138-12
2080
138, US gals. Vertical
44”
27”
30”
12 ga
157 lbs.
68243
Domestic Oil Tank
138R-12
3005224
138, US gals. Horizontal Round
60”
26”
—
12 ga
170 lbs.
153622
In reference to: UL Listing
220-12
2070
220, US gals. Vertical/Stubbies
44”
27”
48”
12 ga
218 lbs.
179514
240V12
2020
240, US gals, Narrow/Vertical
47”
23”
60”
12 ga
264 lbs.
870721
275-12
2040
275, US gals, Vertical
44”
27”
60”
12 ga
252 lbs.
34558
120
Requires outlet opening of 1/2” minimum to be located underneath the tank only. Requires all top openings to be 2” minimum diameter. Tanks which do not meet above requirements cannot be UL 80 labeled.
gauge weight
Webb#
275F-12
2045
275, US gals, Horizontal
27”
44”
60”
12 ga
252 lbs.
34559
330
2050
330, US gals, Vertical
44”
27”
72”
12 ga
290 lbs.
34410
330F-12
2055
330, US gals, Horizontal
27”
44”
60”
12 ga
320 lbs.
79398
Double Bottom Leak Detection and Containment System
Alarm System Safety Double bottom tank with leak detector • Standard float leak detection system. • Optional electronic alarm. system eliminates leakage risk. 15-year warranty plus $2 million* in insurance coverage Residential Oil Tanks with ECOGARD dimenSions Mfr#
CAPACITY
model
gauge
H
W
L
weight
Webb#
244201
275 US gals.
Vert.
12 ga.
44”
27”
60”
290 lbs.
378840
245201
330 US gals.
Vert.
12 ga.
44”
27”
72”
334 lbs.
379850
Aboveground Skid Tanks UL 142 Polyurethane External Coating
Technical Specifications • Steel ASTM A-569. • Tested at pressure 5 to 7 PSIG. • External Finish: Grey Alkyd paint. • Skids have been proof tested under severe UL 142 requirements. dimenSions
Aboveground Tank
Mfr#
models
H
L
gauge
Emergency vent diameter (f)
weight
Webb#
3011423
300 US gals.
38”
60”
12 ga.
3”
370 lbs.
86395
3020445
500 US gals.
50”
48”
7 ga.
4”
845 lbs.
110490
Underground Tanks Single Wall Protected
150 10_Oil Heating_p155.indd 150-151
Mfr#
CAPACITY
model
gauge
H
W
L
weight
Webb#
204201P
275 US gals.
Vert.
12 ga.
44”
27”
60”
252 lbs.
308269
204701P
275 US gals.
Horiz.
12 ga.
44”
27”
60”
252 lbs.
318917
205201P
330 US gals.
Vert.
12 ga.
44”
27”
72”
295 lbs.
308685
205701P
330 US gals.
Horiz.
12 ga.
44”
27”
72”
295 lbs.
319170
10
dimenSions
Mfr#
models
Dia. x length
A
B
C
D
gauge
weight
Webb#
3020344
500 US gals.
50” X 5’
5”
9”
9”
5”
7 ga.
830 lbs.
69927
3039342
1000 US gals.
50” X 10’
9”
16”
16”
8”
7 ga.
1350 lbs.
69928
F.W. Webb Company
dimenSions
Residential Oil Tanks with ECOGARD & PROTEC20
opening location
Underground Tank
Residential Oil Tanks with PROTEC20
www.fwwebb.com
Mfr#
CAPACITY
model
gauge
H
W
L
weight
Webb#
244201P
275 US gals.
Vert.
12 ga.
44”
27”
60”
290 lbs.
379917
245201P
330 US gals.
Vert.
12 ga.
44”
27”
72”
334 lbs.
379918
The F.W. Webb Heating Catalog
F.W. Webb Company
OIL HEATING
Technical Specifications • Steel ASTM A-569, A-635 or A-283 Gr. C. • Tested at pressure 5 to 7 PSIG. • External Finish: Black Alkyd paint. • UL 58 label.
Better External Protection The polyurethane coating could resist to pressure up to 25 psi (maximum operating pressure is 1 psi.), ensuring high safety and protection against leakage caused by corrosion Lifetime The finish prevents external corrosion and is UV resistant to protect colors 20-year extended manufacturer’s warranty* plus $2 million in insurance coverage
151 3/23/08 9:46:03 PM
Oil Heating
2 in 1 Safety Tank System
SECTION
SECTION
10
10
Oil Heating
2 in 1 Safety Tank System
Vent Caps
GRANBY double-wall tanks are designed to offer the highest level of environmental protection. Every inner GRANBY tank is made of blowmolded, high-density polyethylene that is seamless and absolutely leak-proof and corrosion-resistant. In addition, GRANBY tanks feature top connections to ensure the oil stays where it should. The outer tank is made of leak-proof corrosion resistant steel which is capable of containing at least 110% of the capacity of the inner tank for maximum protection. GRANBY tanks are completely rust-free, inside and out. The outer tank is made of galvanized steel, rollseamed (no welds) with an oil and fire resistant seal, making it one of the safest and most reliable tanks on the market. GRANBY uses state-of-the-art technology to ensure maximum storage safety and minimum space requirements. Features: • Weld-free galvanized steel outer tank capable of holding 110% of the inner tank. • Seamless high-density polyethylene inner tank. • Highly visible optical leak alarm. • 55% lighter than a 12-gauge steel tank with a larger storage capacity. • C orrosion resistant steel filling system and external 2” thread, allowing for an even level in each tank when installed in groups. • Cover for outside use.
mfr# description With Screen 4037 11/4” With Screen 4038 11/2” With Screen 4039 2” With Screen Mushroom Vent Caps 4021 3/4” Threaded 4022 1” Threaded 4023 11/4” Threaded 4024 11/2” Threaded 4025 2” Threaded
Mfr#
CAPACITY US Gals.
Dimensions H
W
L
Webb#
R2335191861
165
61”
28”
29”
367737
R2335191862
275
61”
28”
43”
367736
mfr# R2335001863 R2350000999 R2350000026 R2350000027 R2315007012
R2335100222
R2335100749
R2335100757
description Sealed Fuel Oil Gauge (165 and 275 G.) Vent Alarm 2in. NPT 3/8” Duplex Bushing with fittings 1/2” Duplex Bushing with fittings Duplex kit #1: (duplex bushing & vent alarm not) Tie Down kit (need one for 165 G and two for the 275) Galvanized cover for outside application (for 165 G.) Galvanized cover for outside application (for 275 G.)
webb# 9813 91128 91127
webb# 367735 367733 372844 379919
mfr# 3312 3315 3320 3515 3212 3215 3220 3412 3415 3420 3100
description 11/4” Male Straight Adapter 11/2” Male Straight Adapter 2” Male Straight Adapter 11/2” Male 45° Adapter 11/4” Female Straight Adapter 11/2” Female Straight Adapter 2” Female Straight Adapter 11/4” Female 45° Adapter 11/2” Female 45° Adapter 2” Female 45° Adapter Unifil Standard Cap
mfr# description Hinge Type 4164 2” Male Thread 4171 2”
378972 371966
webb# 69643
webb#
Detects the presence of water in petroleum and petroleum based products. Turns violet on contact with water. mfr# 61-405
description Water Paste
webb# 55862
Metal Gas Cans & Accessories mfr# 11010 11410 11910 11915 12020 12040 12910
description webb# 5 gal. Gas Can 256832 Gas Can Carrier With Strap 256833 Metal Lid Gasket 256834 Metal Lid for 5 Gal. Can 256835 11/4” Screw-on Spout 256836 3/4” Screw-on Spout 256837 Metal Spout Gasket 256838
55873 55844
mfr# description webb# Slip-Thru 4468 2” X 3/8” X 3/8” 55877 Solid Body 4-Way Tap DupleX Slip-Thru 4475 2” X 3/8” X 3/8” 55847 DupleX Bushing 4476 2” X 1/2” X 1/2” 55848
www.fwwebb.com
webb#
The F.W. Webb Heating Catalog
10 OIL HEATING
10_Oil Heating_p155.indd 152-153
description Tank Patch
Tank Bushings
273737
mfr# description Duple X Fittings 4482 3/8” Comp X 3/8” IPS 4484 1/2” Comp X 1/2” IPS
F.W. Webb Company
webb# 54498 57838 69871 69870 36644 57840 58842 54499 57839 58843 36643
part# webb# UF122 79475
Replacement Parts
152
mfr# S216W
Tank Fill Adapters
Fill Boxes
367732
Instantly stops small leaks in steel tanks. A powerful permanent magnet holds a flexible plug against the hole and against existing pressure. Saves time. Can be re-used. The quickest tank repair possible.
55864 55865 55866 55867 55868
mfr# description 04346 Unifil Nozzle Connector
Accessories
Oil Tank Patch™
F.W. Webb stocks riello parts!
55878 77847
F.W. Webb Company
153 3/23/08 9:47:45 PM
Oil Heating Tank Gauges Ventalarm®
Gauges
Scully tank gauges feature durable and leak-proof construction. They have easy to read level indicators and are simple to install. • One unit fill alarm and level indicator saves installation costs. • Protects against spills. mfr# 01402 01406 01409 01413 01444 01445 01456
desc. Depth 11/2” X 11/4” 26” – 27” 11/2” X 11/4” 42” – 44” 2” X 11/4” 26” – 27” 2” X 11/4” 42” – 44” 2” X 11/2” 26” – 27” 2” X 11/2” 42” – 44” 2” X 2” 42” – 44”
part# webb# VG125-26 20197 VG125-42 20196 VG126-26 70303 VG126 20199 94512 76536 95164
SECTION
SECTION
10
10
Tank Fill Signals Used for above and below ground tanks Ventalarm® Signals
Inline Fusible Valves
Scully tank fill signals whistle when the tank is filling. When the whistle stops, the tank is full. The calibrated whistle stems allow for product expansion and may be cut for flat style tanks. A patented screen keeps the whistle chamber free from pipe scale and bugs. mfr# 00201 00202 00215 00216 00209 00275
description 11/4” X 11/4” 11/2” X 11/2” 2” X 11/4” 2” X 11/2” 2” X 2” 2” X 2” (Vert/Flat)
part# webb# VS201 20192 VS202 20193 VS521 70304 VS530 110528 VS270 79005 VS524 94064
®
• Inexpensive and accurate level indicator. • Leak-proof construction with non-rusting zinc casting. • Dual bushing fits both 11/2” & 2” tank holes. mfr# Depth 01421 26” – 27” 01422 42” – 44”
part# EG216 EG215
webb# 69875 34260
Snorkel® Gauges • Takes clean, dry fuel from 1” below the surface. • Provides a return line opening. • Two piece assembly makes installation easier. • One unit fits both 11/2” & 2” tank bushings. mfr# Depth part# 01416 42” – 44” TS120 10159 Replacement Vial & Gasket
webb# 69876 69094
Globe Valve, 1/2” X 1/2” NPT
87707
9800
mfr# B100HCV B100CV
description 3/8” X 3/8”, Silver cap 3/8” X 3/8”, Brass cap
webb# 9804 9805
100HVC B200HCV B200CV B105HVC 105HVC* B205HVC
3/8” X 3/8”, Silver cap 1/2” X 1/2”, Silver cap 1/2” X 1/2”, Brass cap
87708 95598 9806 76575 76484 76576
3/8” X 3/8”, Flare, Silver cap 3/8” X 3/8”, Flare, Silver cap 1/2” X 1/2”, Flare, Silver cap
* Cast Bronze
Lever Valves B300F
Globe Valve, 3/4” X 3/4” NPT
84867
B105F B205F
Globe Valve, 3/8” X 3/8” NPT Globe Valve, 1/2” X 1/2” Flare
9799 70302
mfr# B100L
description 3/8” X 3/8”, With Access
webb# 9807
• Installs without removing the existing vent pipe. • Special leak-proof fitting joins and seals Vent alarm to pipe. • No threading or additional fittings required. mfr# 00203
OEM Replacement Gauge Vial description With Gasket
Handwheel
description part# webb# 11/4” X 11/4” VS221 20195
mfr# HW165
Burner (Angle) Fusible Valves Compression Pipe Couplings • Lets you replace a tank without removing fill and vent pipes. • Rugged design makes pipe connections secure and leak free. • Gaskets keep any fumes from leaking. mfr# 01116 01117 01122
description 11/4” 11/2” 2”
part# webb# AF251 69872 AF252 69873 AF253 70305
mfr# B104CFS B204CFXL B204CF
description 3/8” X 1/4”, Short Shank 1/2” X 1/4”, Short Shank 1/2” FL X 1/4” NPT, Short Shank
webb# 91992 70051 246671
B104F B104CF 104CF* B204CFL
3/8” COMP X 1/4” NPT 3/8” Flare X 1/4” NPT 3/8” Flare X 1/4” NPT 1/2” Flare X 1/4” NPT
9797 9794 164598 70051
B104FXL 3/8” COMP X 1/4” NPT B104CFXL 3/8” Flare X 1/4” NPT
9798 30214
description webb# f/Fusible Valve & Thermal Switch 9809
Oil Tank Valves Hard Seat Oil Tank Valves mfr# 111-203
description 1/2” M X 3/8” M T-561
webb# 179512
webb# 82561
F.W. Webb Company
Wireless Fuel Level Monitor • • • •
Monitor oil level from your kitchen. No more trips outside or into the basement. Installs in both basement and outside above ground tanks. Takes 10 minutes to install—no wiring needed.
mfr# 7000 7012 7015 7050
description Rocket Fuel Monitor with 2” Adapter Rocket Adapter 11/4” NPT Rocket Adapter 11/2” NPT Rocket Wireless Receiver only
webb# 308056 308057 308058 308060
www.fwwebb.com
10
Tank-Filter Fusible Valves mfr# description 191TF 1/2” X 3/8”, Bottom Outlet 141TFSBV* 1/2” X 3/8”, Bottom Outlet
webb# 9803 111862
3/8” X 3/8”, Straight
9802
140TFSBV* 3/8”, Bottom Outlet
75892
131TF
OIL HEATING
description webb# 42-44” Vertical Tank Gauge 78055 Replacement top kit w/gaskets 78054
10_Oil Heating_p155.indd 154-155
Globe Valve, 3/8” X 3/8”, Cast Brass
Check Valves webb# 9793
* Cast Bronze
Clearview Indoor-Outdoor
154
100F
B200F
Oil Tank Gauge
mfr# 4495
mfr# description B100F Globe Valve, 3/8” X 3/8”, Brass
Compression Ventalarm® Signals
Econ-O-Gages
mfr# 8000 8005
Oil Heating
F.W. Webb stocks burnham heating products!
* With Sludge Bypass Feature
The F.W. Webb Heating Catalog
F.W. Webb Company
155 3/23/08 9:49:03 PM
Flare Fittings Grooved Polyethylene–Coated Soft Copper Tubing for Fuel Oil Polyethylene coating features controlled double wall containment Oil Pro-Tec® features a revolutionary concept in fuel oil tubing. The Uniquely designed polyethylene coating protects both the environment from oil contaminants and the copper tubing from corrosion. The coating features special grooves that contain the fuel oil in the event of a line failure and provides for early leak detection. mfr# 38X50CTD 38X100CTD 12X50CTD 12X100CTD
description Orange Copper 3/8” X 50’ Orange Copper 3/8” X 100’ Orange Copper 1/2” X 50’ Orange Copper 1/2” X 100’
SECTION
SECTION
11
11
Insulated Hangers
Brass Flare Fittings
Inso-Line Strap Hanger
#42 Flare X Flare Union
• Nails included. • Copper coated for corrosion resistance. • Prevents vibration noise. Mfr# Pipe Size Hanger Length Webb# 601-1 1/2” 6” 46 601-2 3/4” 6” 47
Inso-Line & Plain Glide Clips • Copper-clad nails included. • Allows silent sliding of supported tubing. Mfr# Pipe Size Webb# 604-1 1/2” 75 604-2 3/4” 72656 604-3 1” 77
webb# 201445 201446 213315 213316
#48 Flare X Male (MPT) Union
Mfg# Code Size webb# U2-2 U2-3 U2-4 U2-5 U2-6 U2-8 U2-10 U2-12 U2-14
SAE18UN SAE316UN SAE14UN SAE516UN SAE38UN SAE12UN SAE58UN SAE34UN SAE78UN
19795 19796 19797 19798 19799 19801 19802 19803 19804
1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4 7/8
#42R Flare X Flare Reducing Union Mfg# Code Size UR2-64 UR2-86 UR2-108 UR2-84 UR2-106 UR2-128
Standard Copper Tubing mfr#
SAE38X14UN SAE12X38UN SAE58X12UN SAE12X14UN SAE58X38UN SAE34X12UN
webb#
3/8 X 1/4 1/2 X 3/8 5/8 X 1/2 1/2 X 1/4 5/8 X 3/8 3/4 X 1/2
30291 34574 34820 34818 34819 34821
#46 Flare X Female (FPT) Union
C/T14K100 C/T38K100 C/T12K100
Mfg# Code Size webb# U3-3A U3-4A U3-4B U3-6A U3-6B U3-6C U3-6D U3-6E U3-8B U3-8C U3-8D U3-8E U3-10C U3-10D U3-10E U3-12E
C/T14L100 C/T38L100 C/T12L100
C/T14OD100 C/T38OD100 C/T516OD100 C/T12OD100 C/T58OD100
SAE316ODX18FA SAE14ODX18FA SAE14ODXFA SAE38ODX18FA SAE38ODX14FA SAE38ODXFA SAE38ODX12FA SAE38ODX34FA SAE12ODX14FA SAE12ODX38FA SAE12ODXFA SAE12ODX34FA SAE58ODX38FA SAE58ODX12FA SAE58ODX34FA SAE34ODX34FA
3/16 X 1/8 1/4 X 1/8 1/4 X 1/4 3/8 X 1/8 3/8 X 1/4 3/8 X 3/8 3/8 X 1/2 3/8 X 3/4 1/2 X 1/4 1/2 X 3/8 1/2 X 1/2 1/2 X 3/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4 3/4 X 3/4
19747 19748 19749 19754 19755 19756 19757 19758 19759 19760 19761 19762 19763 19764 19765 19767
#114 Swivel Nut • • • • •
Is wholesale only is made in the usa has true 40,000 btu’s on 40 gallon has a patented “hydrojet” system Has a patented 304L Stainless Steel “Screenlock” system • has a factory installed T&P valve • has a patented “vitraglass” lining
156 11_Pipe&Fittings_p163.indd 156-157
F.W. Webb Company
www.fwwebb.com
Mfg# Code Size webb# US4-4 SAE14SWIVELNUT US4-6 SAE38SWIVELNUT US4-8 SAE12SWIVELNUT US4-10 SAE58SWIVELNUT US4-86 SAE12X38SWIVELNUT US4-108 SAE58X12SWIVELNUT
1/4 3/8 1/2 5/8 1/2 X 3/8 5/8 X 1/2
The F.W. Webb Heating Catalog
78995 77598 77599 78996 95739 95738
Mfg#
Code
Size
webb#
U1-2A U1-3A U1-4A U1-4B U1-4C U1-4D U1-5A U1-5B U1-5C U1-6A U1-6B U1-6C U1-6D U1-6E U1-8B U1-8C U1-8D U1-8E U1-10B U1-10C U1-10D U1-10E U1-12D U1-12E U1-14E
SAE18MUN SAE316X18MUN SAE316X14MUN SAE14X18MUN SAE14MUN SAE14X38MUN SAE14X12MUN SAE516X18MUN SAE516X14MUN SAE516X38MUN SAE38X18MUN SAE38X14MUN SAE38X38MUN SAE38X12MUN SAE38X34MUN SAE12X14MUN SAE12X38MUN SAE12X12MUN SAE12X34MUN SAE58X14MUN SAE58X38MUN SAE58X12MUN SAE58X34MUN SAE34X12MUN SAE34ODX34MUN SAE78X34MUN
1/8 X 1/8 3/16 X 1/8 3/16 X 1/4 1/4 X 1/8 1/4 X 1/4 1/4 X 3/8 1/4 X 1/2 5/16 X 1/8 5/16 X 1/4 5/16 X 3/8 3/8 X 1/8 3/8 X 1/4 3/8 X 3/8 3/8 X 1/2 3/8 X 3/4 1/2 X 1/4 1/2 X 3/8 1/2 X 1/2 1/2 X 3/4 5/8 X 1/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4 3/4 X 1/2 3/4 X 3/4 7/8 X 3/4
19769 19770 19771 19772 19773 19774 19775 19776 19777 19778 19779 19780 19781 19782 19783 19784 19785 19786 19787 19788 19789 19790 19791 19792 19793 19794
#446 Flare Cap Mfg#
Code
Size
webb#
N5-3 N5-4 N5-5 N5-6 N5-8 N5-10
SAE316CAP SAE14CA SAE516CAP SAE38CA SAE12CA SAE58CAP
3/16 1/4 5/16 3/8 1/2 5/8
19735 19736 19737 19738 19739 19740
PIPE & FITTINGS
webb# mfr# webb# K Tubing 187618 2525 C/T14K60 2526 C/T38K60 191720 2539 C/T12K60 150326 111921 C/T58K60 L Tubing 190615 2551 C/T14L60 2552 C/T38L60 190614 2553 C/T12L60 91639 Refrigeration Tubing (for Oil Lines) 2578 C/T18OD 2579 C/T316OD 2580 C/T14OD 92012 2581 C/T516OD 58835 2582 C/T38OD 150328 2583 C/T12OD 58836 2584 C/T58OD 58837
Flare Fittings
#447 Flare Plug Mfg#
Code
Size Webb#
P2-3 P2-4 P2-5 P2-6 P2-8 P2-10
SAE316PL SAE14PL SAE516PL SAE38PL SAE12PL SAE58PL
3/16 1/4 5/16 3/8 1/2 5/8
19741 19742 19743 19744 19745 19746
11
#461 Flare Bonnets Mfg#
Code
Size
webb#
B1-4 B1-6 B1-8 B1-10
SAE461-4 SAE38BONNET SAE12BONNET SAE461-10
1/4 3/8 1/2 5/8
185393 185395 185396 185391
F.W. Webb Company
157 3/23/08 9:51:39 PM
Flare Fittings Brass Flare Fittings
11
11
Code
Size
webb#
T2-2 T2-3 T2-4 T2-5 T2-6 T2-8 T2-10 T2-12
SAE18T SAE316T SAE14T SAE516T SAE38T SAE12T SAE58T SAE34T
1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4
19856 19857 19858 19859 19860 19861 19862 19863
#44R Flare X Flare X Flare Reducing Tee Mfg#
Code
Size WEbb#
TR2-446 TR2-664 TR3-668 TR2-886 TR2-10106 TR2-10808 TR2-10810 TR2-868 TR2-8810 TR2-884
SAE14X38T 1/4 X 3/8 34825 SAE38X14T 3/8 X 1/4 34826 SAE38X12T 3/8 X 1/2 34827 SAE12X38T 1/2 X 3/8 34833 SAE58X38T 5/8 X 3/8 34838 SAE58X12T 5/8 X 1/2 34839 SAE58X12X58T 5/8 X 1/2 X 5/8 191825 SAE12X38X12T 1/2 X 3/8 X 1/2 192879 SAE12X58T 1/2 X 5/8 192880 SAE12X14T 1/2 X 1/4 95513
#45 Flare X Flare X Male (MPT) Tee
45° Elbow
Code
Size
webb#
T1-3A T1-6C T1-8D T1-5B T1-6B T1-8C T1-10D T1-8B
SAE316ODX18MT2 SAE38ODX38MT2 SAE12ODX12MT2 SAE516ODX14MT5 SAE38ODX14MT5 SAE12ODX38MT5 SAE58ODX12MT5 SAE12X14MT
3/16 X 1/8 3/8 X 3/8 1/2 X 1/2 5/16 X 1/4 3/8 X 1/4 1/2 X 3/8 5/8 X 1/2 1/2 X 1/4
19865 19872 19875 19881 19883 19886 19888 85451
#481 Forged Flare Nut Mfg#
Code
Size Webb#
NS4-3 NS4-4 NS4-5 NS4-6 NS4-8 NS4-10 NS4-12 NSR4-64 NSR4-65 NSR4-86 NSR4-106 NSR4-108
SAE316NUT SAE14RNUT SAE516RNUT SAE38RNUT SAE12RNUT SAE58RNUT SAE34SRNUT SAE38X14NUT SAE38X516NUT SAE12X38NUT SAE58X38NUT SAE58X12NUT
3/16 19722 1/4 34570 5/16 34813 3/8 34571 1/2 34572 5/8 34814 3/4 34815 3/8 X 1/4 78997 3/8 X 5/16 78998 1/2 X 3/8 85455 5/8 X 3/8 212746 5/8 X 1/2 95512
F.W. Webb Company
Mfg#
Code
E2-2 SAE1890 E2-3 SAE31690 E2-4 SAE1490 E2-5 SAE51690 E2-6 SAE3890 E2-8 SAE1290 E2-10 SAE5890 E2-12 SAE3490 ER2-64 SAE38X1490 ER2-86 SAE12X3890 ER2-106 SAE58X3890 ER2-108 SAE58X1290
Size
webb# 19847 19848 19849 19850 19851 19852 19853 19854 34823 34824 94502 94503
1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4 3/8 X 1/4 1/2 X 3/8 5/8 X 3/8 5/8 X 1/2
#49 Flare X Male (MPT) Elbow Mfg#
Code
Size
webb#
E1-2A E1-3A E1-3B E1-4A E1-4B E1-4C E1-4D E1-5A E1-5B E1-5C E1-6A E1-6B E1-6C E1-6D E1-6E E1-8B E1-8C E1-8D E1-8E E1-10C E1-10D E1-10E E1-12D
SAE18M90 SAE316X18M90 SAE316X14M90 SAE14X18M90 SAE14M90 SAE14X38M90 SAE14ODX12M90 SAE516X18M90 SAE516X14M90 SAE516X38M90 SAE38X18M90 SAE38X14M90 SAE38X38M90 SAE38X12M90 SAE38ODX34M90 SAE12X14M90 SAE12X38M90 SAE12X12M90 SAE12ODX34M90 SAE58X38M90 SAE58ODX12M90 SAE58ODX34M90 SAE34ODX12M90
1/8 3/16 X 1/8 3/16 X 1/4 1/4 X 1/8 1/4 1/4 X 3/8 1/4 X 1/2 5/16 X 1/8 5/16 X 1/4 5/16 X 3/8 3/8 X 1/8 3/8 X 1/4 3/8 X 3/8 3/8 X 1/2 3/8 X 3/4 1/2 X 1/4 1/2 X 3/8 1/2 X 1/2 1/2 X 3/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4 3/4 X 1/2
19823 19824 19825 19826 19827 19828 19829 19830 19831 19832 19833 19834 19835 19836 19837 19838 19839 19840 19841 19843 19844 19845 19846
#564 Flare X Female (FPT) Elbow Mfg#
Code
Size Webb#
E3-6C E3-6D E3-8D E3-8E E3-10C E3-10D E3-10E
SAE38ODX38F90 SAE38ODX12F90 SAE12ODX12F90 SAE12ODX34F90 SAE58ODX38F90 SAE58ODX12F90 SAE58ODX34F90
3/8 X 3/8 3/8 X 1/2 1/2 X 1/2 1/2 X 3/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4
19813 19814 19818 19819 19820 19821 19822
www.fwwebb.com
MFR# MAL1845 MAL1445 MAL3845 MAL1245 MAL3445 MAL145 MAL11445 MAL11245 MAL245 MAL21245 MAL345
Cross SIZE WEBB# 12559 12560 12561 12562 12563 1” 12564 11/4” 12565 11/2” 12566 2” 12567 21/2” 12568 3” 12569
1/8” 1/4” 3/8” 1/2” 3/4”
45° Street Elbow MFR# MAL18S45 MAL14S45 MAL38S45 MAL12S45 MAL34S45 MAL1S45 MAL114S45 MAL112S45 MAL2S45
SIZE WEBB# 1/8” 12574 1/4” 12575 3/8” 12576 1/2” 12577 3/4” 12578 1” 12579 11/4” 12580 11/2” 12581 2” 12582
MFR# MAL1845 MAL14CR MAL38CR MAL12CR MAL34CR MAL1CR MAL114CR MAL112CR MAL2CR
SIZE WEBB# 1/8” 12759 1/4” 12760 3/8” 12761 1/2” 12762 3/4” 12763 1” 12764 11/4” 12765 11/2” 12766 2” 12767
Coupling MFR# MAL18CO MAL14CO MAL38CO MAL12CO MAL34CO MAL1CO MAL114CO MAL112CO MAL2CO MAL3CO
SIZE WEBB# 12774 1/4” 12775 3/8” 12776 1/2” 12777 3/4” 12778 1” 12779 11/4” 12780 11/2” 12781 2” 12782 3” 12784
1/8”
90° Elbow MFR# MAL1890 MAL1490 MAL3890 MAL1290 MAL3490 MAL190 MAL11490 MAL11290 MAL290 MAL21290 MAL390
SIZE WEBB# 1/8” 12503 1/4” 12504 3/8” 12505 1/2” 12506 3/4” 12507 1” 12508 11/4” 12509 11/2” 12510 2” 12511 21/2” 12512 3” 12513
90° Street Elbow MFR# MAL18S90 MAL14S90 MAL38S90 MAL12S90 MAL34S90 MAL1S90 MAL114S90 MAL112S90 MAL2S90 MAL212S90
SIZE WEBB# 1/8” 12547 1/4” 12548 3/8” 12549 1/2” 12550 3/4” 12551 1” 12552 11/4” 12553 11/2” 12554 2” 12555 21/2” 12556
90° Reducing Elbow MFR# SIZE WEBB# MAL14X1890 1/4” X 1/8” 12518 MAL38X1490 3/8” X 1/4” 12519 MAL12X3890 1/2” X 3/8” 12521 MAL12X1490 1/2” X 1/4” 12522 MAL34X1290 3/4” X 1/2” 12523 MAL34X3890 3/4” X 3/8” 12524 MAL34X1490 3/4” X 1/4” 12525 MAL1X3490 1” X 3/4” 12526 MAL1X1290 1” X 1/2” 12527 MAL114X190 11/4” X 1” 12529 MAL114X3490 11/4” X 3/4” 12530 MAL114X1290 11/4” X 1/2” 12531 MAL112X11490 11/2” X 11/4”12532 MAL112X190 11/2” X 1” 12533 MAL112X3490 11/2” X 3/4” 12534 MAL2X11290 2” X 11/2” 12535 MAL2X11490 2” X 11/4” 12536 MAL2X190 2” X 1” 12537 MAL2X3490 2” X 3/4” 12538 MAL212X290 21/2” X 2” 12539 MAL212X11290 21/2” X 11/2”12540 MAL3X21290 3” X 21/2” 12541 MAL3X290 3” X 2” 12542
The F.W. Webb Heating Catalog
Bushing
Plug MFR# Solid BCI18SOPL BCI14SOPL BCI38SOPL BCI12SOPL BCI34SOPL BCI1SOPL BCISO2PL Cored BCI12PL BCI34PL BCI1PL BCI114PL BCI112PL BCI2PL BCI212PL BCI3PL
SIZE WEBB#
1/4” 3/8” 1/2” 3/4” 1” 2”
1380 1381 1382 1383 1371 197665 1388
1/2” 3/4” 1” 11/4” 11/2” 2” 21/2” 3”
206693 203284 1385 1373 1387 1375 1376 1377
1/8”
Cap MFR# MAL18CA MAL14CA MAL38CA MAL12CA MAL34CA MAL1CA MAL114CA MAL112CA MAL2CA MAL212CA MAL3CA
SIZE WEBB# 1/8” 12851 1/4” 12852 3/8” 12853 1/2” 12854 3/4” 12855 1” 12856 11/4” 12857 11/2” 12858 2” 12859 21/2” 12860 3” 12861
MFR# SIZE WEBB# BCI14X18BU 1/4” X 1/8” 1257 BCI38X14BU 3/8” X 1/4” 1258 BCI38X18BU 3/8” X 1/8” 1259 BCI12X38BU 1/2” X 3/8” 1260 BCI12X14BU 1/2” X 1/4” 1261 BCI12X18BU 1/2” X 1/8” 1262 BCI34X12BU 3/4” X 1/2” 1263 BCI34X38BU 3/4” X 3/8” 1264 BCI34X14BU 3/4” X 1/4” 1265 BCI34X18BU 3/4” X 1/8” 1266 BCI1X34BU 1” X 3/4” 1267 BCI1X12BU 1” X 1/2” 1268 BCI1X38BU 1” X 3/8” 1269 BCI1X14BU 1” X 1/4” 1270 BCI1X18BU 1” X 1/8” 1271 BCI114X1BU 11/4” X 1” 1272 BCI114X34BU 11/4” X 3/4” 1273 BCI114X12BU 11/4” X 1/2” 1274 BCI114X38BU 11/4” X 3/8” 1275 BCI114X14BU 11/4” X 1/4” 1276 BCI114X18BU 11/4” X 1/8” 76976 BCI112X114BU 11/2” X 11/4” 1277 BCI112X1BU 11/2” X 1” 1278 BCI112X34BU 11/2” X 3/4” 1279 BCI112X12BU 11/2” X 1/2” 1280 BCI2X112BU 2” X 11/2” 1283 BCI2X114BU 2” X 11/4” 1284 BCI2X1BU 2” X 1” 1285 BCI2X34BU 2” X 3/4” 1286 BCI2X12BU 2” X 1/2” 1287 BCI212X2BU 21/2” X 2” 1290 BCI212X112BU 21/2” X 11/2” 1291 BCI212X114BU 21/2” X 11/4” 1292 BCI212X1BU 21/2” X 1” 1293 BCI3X212BU 3” X 21/2” 1296 BCI3X2BU 3” X 2” 1297 BCI3X1BU 3” X 1” 1300
Tee
Union MFR# MAL18UN MAL14UN MAL38UN MAL12UN MAL34UN MAL1UN MAL114UN MAL112UN MAL2UN MAL3UN
SIZE WEBB# 1/8” 54291 1/4” 30254 3/8” 30255 1/2” 30256 3/4” 30257 1” 30258 11/4” 30259 11/2” 30260 2” 30262 3” 30263
MFR# MAL18T MAL14T MAL38T MAL12T MAL34T MAL1T MAL114T MAL112T MAL2T MAL212T MAL3T
F.W. Webb Company
SIZE WEBB# 12586 1/4” 12587 3/8” 12588 1/2” 12589 3/4” 12590 1” 12591 11/4” 12592 11/2” 12593 2” 12594 21/2” 12595 3” 12596
1/8”
PIPE & FITTINGS
Mfg#
Flare Fittings
Black Malleable Fittings #55 Flare X Flare Elbow
Mfg#
11_Pipe&Fittings_p163.indd 158-159
SECTION
(cont.)
#44 Flare X Flare X Flare Tee
158
SECTION
11
159 3/23/08 9:51:42 PM
Fittings – Nipples
SECTION
SECTION
11
11 Schedule 40 Nipples
Black Malleable Fittings (cont.) Reducing Tee (cont.)
Reducing Tee
160 11_Pipe&Fittings_p163.indd 160-161
MFR# SIZE WEBB# MAL112X114X112T 11/2” X 11/4” X 11/2” 12667 MAL112X114X114T 11/2” X 11/4” X 11/4” 12668 MAL112X114X1T 11/2” X 11/4” X 1” 12669 MAL112X114X34T 11/2” X 11/4” X 3/4” 12670 MAL112X114X12T 11/2” X 11/4” X 1/2” 12671 MAL112X1X112T 11/2” X 1” X 11/2” 12672 MAL112X1X114T 11/2” X 1” X 11/4” 12673 MAL112X1X1T 11/2” X 1” X 1” 12674 MAL112X1X34T 11/2” X 1” X 3/4” 12675 MAL112X34X112T 11/2” X 3/4” X 11/2” 12677 MAL34X12X34T 11/2” X 3/4” X 1” 12679 MAL112X34X1T 11/2” X 3/4” X 3/4” 12680 MAL112X12X112T 11/2” X 1/2” X 11/2” 12681 MAL2X2X212T 2” X 2” X 21/2” 12684 MAL2X2X112T 2” X 2” X 11/2” 12685 MAL2X2X114T 2” X 2” X 11/4” 12686 MAL2X2X1T 2” X 2” X 1” 12687 MAL2X2X34T 2” X 2” X 3/4” 12688 MAL2X2X12T 2” X 2” X 1/2” 12689 MAL2X112X2T 2” X 11/2” X 2” 12690 MAL2X112X112T 2” X 11/2” X 11/2” 12691 MAL2X112X114T 2” X 11/2” X 11/4” 12692 MAL2X112X1T 2” X 11/2” X 1” 12693 MAL2X112X34T 2” X 11/2” X 3/4” 12694 MAL2X114X2T 2” X 11/4” X 2” 12695 MAL2X114X114T 2” X 11/4” X 11/4” 12697 MAL2X1X2T 2” X 1” X 2” 12699 MAL2X1X1T 2” X 1” X 1” 12702 MAL2X34X2T 2” X 3/4” X 2” 12704 MAL1X12X2T 1” X 1/2” X 2” 12706 MAL212X212X3T 21/2” X 21/2” X 3” 12707 MAL212X212X2T 21/2” X 21/2” X 2” 12708 MAL212X212X112T 21/2” X 21/2” X 11/2” 12709 MAL212X212X114T 21/2” X 21/2” X 11/4” 12710 MAL212X212X1T 21/2” X 21/2” X 1” 12711 MAL212X212X34T 21/2” X 21/2” X 3/4” 12712 MAL212X2X212T 21/2” X 2” X 21/2” 12713 MAL212X2X2T 21/2” X 2” X 2” 12714 MAL212X112X212T 21/2” X 11/2” X 21/2” 12716 MAL212X112X2T 21/2” X 11/2” X 2” 12717 MAL3X3X212T 3” X 3” X 21/2” 12719 MAL3X3X2T 3” X 3” X 2” 12720 MAL3X3X112T 3” X 3” X 11/2” 12721 MAL3X3X114T 3” X 3” X 11/4” 12722 MAL3X3X1T 3” X 3” X 1” 12723 MAL3X3X34T 3” X 3” X 3/4” 12724 MAL3X212X212T 3” X 21/2” X 21/2” 12726 MAL3X212X2T 3” X 21/2” X 2” 12727 MAL3X2X3T 3” X 2” X 3” 12729 MAL3X2X2T 3” X 2” X 2” 12730
F.W. Webb Company
Reducing Coupling MFR# SIZE WEBB# BCI14X18CO 1/4” X 1/8” 12789 BCI38X14CO 3/8” X 1/4” 12790 BCI38X18CO 3/8” X 1/8” 12791 BCI12X38CO 1/2” X 3/8” 12792 BCI12X14CO 1/2” X 1/4” 12793 BCI12X18CO 1/2” X 1/8” 12794 BCI34X12CO 3/4” X 1/2” 12795 BCI34X38CO 3/4” X 3/8” 12796 BCI34X14CO 3/4” X 1/4” 12797 BCI34X18CO 3/4” X 1/8” 12798 BCI1X34CO 1” X 3/4” 12799 BCI1X12CO 1” X 1/2” 12800 BCI1X38CO 1” X 3/8” 12801 BCI1X14CO 1” X 1/4” 12802 BCI114X1CO 11/4” X 1” 12803 BCI114X34CO 11/4” X 3/4” 12804 BCI114X12CO 11/4” X 1/2” 12805 BCI114X38CO 11/4” X 3/8” 12806 BCI114X14CO 11/4” X 1/4” 12808 BCI112X114CO 11/2” X 11/4” 12808 BCI112X1CO 11/2” X 1” 12809 BCI112X34CO 11/2” X 3/4” 12810 BCI112X12CO 11/2” X 1/2” 12811 BCI2X112CO 2” X 11/2” 12813 BCI2X114CO 2” X 11/4” 12814 BCI2X1CO 2” X 1” 12815 BCI2X34CO 2” X 3/4” 12816 BCI2X12CO 2” X 1/2” 12817 BCI212X2CO 21/2” X 2” 12818 BCI212X112CO 21/2” X 11/2” 12819 BCI212X114CO 21/2” X 11/4” 12820 BCI212X1CO 21/2” X 1” 12821 BCI3X212CO 3” X 21/2” 12822 BCI3X2CO 3” X 2” 12823 BCI3X112CO 3” X 11/2” 12824 BCI3X114CO 3” X 11/4” 12825 BCI3X1CO 3” X 1” 12826
Floor Flanges MFR# SIZE WEBB# MAL12FLFLG 1/2” 12879 MAL34FLFLG 3/4” 12880 MAL1FLFLG 1” 12881 MAL114FLFLG 11/4” 12882 MAL112FLFLG 11/2” 12883 MAL2FLFLG 2” 12884
www.fwwebb.com
1/8” — 1” SIZE
part# webb# part# webb# part# webb# part# webb# part# webb# pART# WEBB# 1/8” 1/4” 3/8” 1/2” 3/4” 1”
LOSE C 1 11/2 2 21/2 3 31/2 4 41/2 5 51/2 6 61/2 7
NIP18XCLO 14121 NIP14XCLO 14132 NIP38XCLO 14143 NIP18X1 89013 NIP14X1 90178 NIP18X112 14122 NIP14X112 14133 NIP38X112 14144 NIP18X2 14123 NIP14X2 14134 NIP38X2 14145 NIP18X212 14124 NIP14X212 14135 NIP38X212 14146 NIP18X3 14125 NIP14X3 14136 NIP38X3 14147 NIP18X312 14126 NIP14X312 14137 NIP38X312 14148 NIP18X4 14127 NIP14X4 14138 NIP38X4 14149 NIP18X412 14128 NIP14X412 14139 NIP38X412 14150 NIP18X5 14129 NIP14X5 14140 NIP38X5 14151 NIP18X512 14130 NIP14X512 14141 NIP38X512 14152 NIP18X6 14131 NIP14X6 14142 NIP38X6 14153 NIP38X612 153667 NIP18X7 110506 NIP14X7 93181 NIP38X7 67730
71/2 8 81/2 9 91/2 10 101/2 11 12 13 14 15 16 17 171/2 18 19 20 21 22 24 26 27 28 30 36 40 42 43 48 53 54 60
NIP38X712 213295 NIP12X712 225065 NIP18X8 89010 NIP14X8 90181 NIP38X8 110509 NIP12X8 14166 NIP34X8 14183 NIP38X812 90197 NIP12X812 90217 NIP18X9 153003 NIP14X9 86243 NIP38X9 213167 NIP12X9 14167 NIP34X9 14184 NIP34X912 209203 NIP18X10 153238 NIP14X10 90179 NIP38X10 79993 NIP12X10 14168 NIP34X10 14185 NIP34X1012 225069 NIP14X11 206628 NIP38X11 90199 NIP12X11 14169 NIP34X11 14186 NIP14X12 90180 NIP38X12I 153004 NIP12X12 14170 NIP34X12 14187 NIP38X13 225073 NIP12X13 91833 NIP34X13 209208 NIP14X14 85164 NIP12X14 85163 NIP34X14 92234 NIP34X15 83865 NIP38X16 242818 NIP12X16 250310 NIP14X18 14776 NIP38X18 14784 NIP12X18 14792 NIP34X18 14800
NIP12XCLO NIP12X1 NIP12X112 NIP12X2 NIP12X212 NIP12X3 NIP12X312 NIP12X4 NIP12X412 NIP12X5 NIP12X512 NIP12X6 NIP12X612 NIP12X7
14154 184981 14155 14156 14157 14158 14159 14160 14161 14162 14163 14164 90214 14165
NIP34XCLO 14171 NIP1XCLO NIP34X112 NIP34X2 NIP34X212 NIP34X3 NIP34X312 NIP34X4 NIP34X412 NIP34X5 NIP34X512 NIP34X6 NIP34X612 NIP34X7
NIP34X20
14172 14173 14174 14175 14176 14177 14178 14179 14180 14181 86309 14182
NIP114X112 NIP1X2 NIP1X212 NIP1X3 NIP1X312 NIP1X4 NIP1X412 NIP1X5 NIP1X512 NIP1X6 NIP1X7 NIP1X712 NIP1X8 NIP1X812 NIP1X9 NIP1X912 NIP1X10 NIP1X1012 NIP1X11 NIP1X12 NIP1X13 NIP1X14 NIP1X15 NIP1X16 NIP1X17 NIP1X1712 NIP1X18
14188 90247 14189 14190 14191 14192 14193 14194 14195 14196 14197 14198 225068 14199 210728 14200 243409 14201 225066 14202 14203 218014 86475 83866 95382 247341 225067 14808
90233
NIP1X22 NIP14X24 14777 NIP38X24 14785 NIP12X24 14793 NIP34X24 14801 NIP1X24
198537 14809
NIP34X28 250047 NIP34X30 14802 NIP1X30 NIP34X36 14803 NIP1X36 NIP34X40 250050 NIP1X40 NIP34X42 14804 NIP1X42
14810 14811 250046 14812
NIP14X30 14778 NIP12X30 14794 NIP14X36 14779 NIP12X36 14795
NIP14X48 14781 NIP12X48 14797 NIP34X48 14805 NIP34X54 14806 NIP12X60 14799 NIP34X60 14807
The F.W. Webb Heating Catalog
NIP1X48 NIP1X53 NIP1X54 NIP1X60
F.W. Webb Company
PIPE & FITTINGS
MFR# SIZE WEBB# MAL18X18X14T 1/8” X 1/8” X 1/4” 12601 MAL14X14X18T 1/4” X 1/4” X 1/8” 12603 MAL38X38X14T 3/8” X 3/8” X 1/4” 12605 MAL38X14X14T 3/8” X 1/4” X 1/4” 12608 MAL12X12X1T 1/2” X 1/2” X 1” 12609 MAL12X12X34T 1/2” X 1/2” X 3/4” 12610 MAL12X12X38T 1/2” X 1/2” X 3/8” 12611 MAL12X38X12T 1/2” X 3/8” X 1/2” 12613 MAL12X38X38T 1/2” X 3/8” X 3/8” 12614 MAL12X14X12T 1/2” X 1/4” X 1/2” 12615 MAL34X12X12T 3/4” X 1/2” X 1/2” 12622 MAL34X12X34T 3/4” X 1/2” X 3/4” 12621 MAL34X14X34T 3/4” X 1/4” X 3/4” 12625 MAL34X34X114T 3/4” X 3/4” X 11/4” 12616 MAL34X34X12T 3/4” X 3/4” X 1/2” 12618 MAL34X34X14T 3/4” X 3/4” X 1/4” 12620 MAL34X34X1T 3/4” X 3/4” X 1” 12617 MAL34X34X38T 3/4” X 3/4” X 3/8” 12619 MAL1X1X12T 1” X 1” X 1/2” 12626 MAL1X1X112T 1” X 1” X 11/2” 12627 MA1X1X114T 1” X 1” X 11/4” 12628 MAL1X1X38T 1” X 1” X 3/8” 12631 MAL1X1X12T 1” X 1” X 1/2” 12632 MAL1X34X1T 1” X 3/4” X 1” 12633 MAL1X34X34T 1” X 3/4” X 3/4” 12634 MAL1X34X12T 1” X 3/4” X 1/2” 12635 MAL1X12X1T 1” X 1/2” X 1” 12636 MAL1X12X34T 1” X 1/2” X 3/4” 12637 MAL1X12X12T 1” X 1/2” X 1/2” 12638 MAL1X14X1T 1” X 1/4” X 1” 12639 MAL114X114X2T 11/4” X 11/4” X 2” 12640 MAL114X114X112T 11/4” X 11/4” X 11/2” 12641 MAL114X114X1T 11/4” X 11/4” X 1” 12642 MAL114X114X34T 11/4” X 11/4” X 3/4” 12643 MAL114X114X12T 11/4” X 11/4” X 1/2” 12644 MAL114X1X112T 11/4” X 1” X 11/2” 12646 MAL114X1X114T 11/4” X 1” X 11/4” 12647 MAL114X1X1T 11/4” X 1” X 1” 12648 MAL114X1X34T 11/4” X 1” X 3/4” 12649 MAL114X1X12T 11/4” X 1” X 1/2” 12650 MAL114X34X114T 11/4” X 3/4” X 11/4” 12651 MAL114X34X1T 11/4” X 3/4” X 1” 12652 MAL114X34X34T 11/4” X 3/4” X 3/4” 12653 MAL114X12X114T 11/4” X 1/2” X 11/4” 12655 MAL114X12X1T 11/4” X 1/2” X 1” 12656 MAL112X112X2T 11/2” X 11/2” X 2” 12661 MAL112X112X114T 11/2” X 11/2” X 11/4” 12662 MAL112X112X1T 11/2” X 11/2” X 1” 12663 MAL112X112X34T 11/2” X 11/2” X 3/4” 12664 MAL112X112X12T 11/2” X 11/2” X 1/2” 12665
Fittings – Nipples
11
14813 210727 14814 14815
161 3/23/08 9:51:43 PM
Fittings – Nipples
SECTION
SECTION
11
11
Schedule 40 Nipples (cont.)
Tank Bushings
11/4” — 3”
part# webb# part# webb# part# webb# part# webb# part# webb# SIZE 11/4” 11/2” 2” 21/2” 3”
11_Pipe&Fittings_p163.indd 162-163
F.W. Webb Company
NIP3XCLO 14264
NIP3X3 NIP3X312 NIP3X4 NIP3X412 NIP3X5 NIP3X512 NIP3X6 NIP3X612 NIP3X7 NIP3X712 NIP3X8
14265 14266 14267 14268 14269 14270 14271 79300 14272 79301 14273
NIP3X9 NIP3X912 NIP3X10 NIP3X1012 NIP3X11 NIP3X12
14274 86318 14275 86307 14276 14277
NIP3X14
67735
NIP3X16
75575
NIP3X18
67324
NIP3X20
67736
NIP3X22 NIP3X24
67737 67325
NIP3X30 NIP3X36
67326 67327
www.fwwebb.com
mfr# description Double Tapped – Outside Hex 4571 11/2” X 3/8” 4580 2” X 11/4” 4581 2” X 11/2” Double Tapped – Inside Hex 4572 11/2” X 1/2” 4576 2” X 3/8” 4577 2” X 1/2” 4578 2” X 3/4” 4579 2” X 1” 4591 3” X 2” 4602 3” X 11/2” 4603 4” X 2” 4605 4” X 3”
webb# 85408 55855 55856 84430 55851 55852 55853 55854 55858 55859 55860 77848
Nipple Box mfr# 3080 3081 3082 3083 3084 3091
size webb# 1/2” 75250 3/4” 75251 1” 75252 11/4” 75253 11/2” 75254 1/2” & 3/4” 75267
Nipple Packs Close X 6” – 1 Each mfr# 12PAK 34PAK 1PAK 114PAK 112PAK 2PAK
size 1/2” X CLO-6” 3/4” X CLO-6” 6” X CLO-6” 11/4” X CLO-6” 11/2” X CLO-6” 2” X CLO-6”
webb# 79416 79417 79418 79419 79420 79421
Schedules 40 & 80 Black Pipe mfr# Plain End D/P14BPE D/P38BPE D/P12BPE D/P34BPE D/P1BPE D/P114BPE D/P112BPE D/P2BPE D/P212BPE D/P3BPE D/P4BPE
size
webb#
1/4”
179384 79878 45484 45500 45518 45533 45488 45504 45522 45474 45508
3/8” 1/2” 3/4”
1” 11/4” 11/2” 2” 21/2” 3” 4”
Threaded & Capped Ends D/P38BTC 3/8” D/P12BTC 1/2” D/P34BTC 3/4” D/P1BTC 1” D/P114BTC 11/4” D/P112BTC 11/2” D/P2BTC 2” D/P212BTC 21/2” D/P3BTC 3” D/P4BTC 4” Plain End D/P14XHBPE 1/4” D/P12XHBPE 1/2” D/P34XHBPE 3/4” D/P1XHBPE 1” D/P114XHBPE 11/4” D/P112XHBPE 11/2” D/P2XHBPE 2” D/P212XHBPE 21/2” D/P3XHBPE 3” D/P4XHBPE 4”
45473 45490 45507 45524 45477 45493 45511 45527 45480 45514 45475 45525 45478 45494 45512 45528 45482 45498 45516 45486
PIPE & FITTINGS
LOSE NIP114XCLO 14204 NIP112XCLO 14219 NIP2XCLO 14235 NIP212XCLO 14250 C 1 11/2 NIP114X112 90247 2 NIP114X2 14205 NIP112X2 14220 21/2 NIP114X212 14206 NIP112X212 14221 NIP2X212 14236 3 NIP114X3 14207 NIP112X3 14222 NIP2X3 14237 NIP212X3 14251 31/2 NIP114X312 14208 NIP112X312 14223 NIP2X312 14238 NIP212X312 14252 4 NIP114X4 14209 NIP112X4 14224 NIP2X4 14239 NIP212X4 14253 41/2 NIP114X412 14210 NIP112X412 14225 NIP2X412 14240 NIP212X412 14254 5 NIP114X5 14211 NIP112X5 14226 NIP2X5 14241 NIP212X5 14255 51/2 NIP114X512 14212 NIP112X512 14227 NIP2X512 14242 NIP212X512 14256 6 NIP114X6 14213 NIP112X6 14228 NIP2X6 14243 NIP212X6 14257 61/2 NIP2X612 213045 7 NIP114X7 14214 NIP112X7 14229 NIP2X7 14244 NIP212X7 14258 71/2 NIP112X712 225057 8 NIP114X8 14215 NIP112X8 14230 NIP2X8 14245 NIP212X8 14259 81/2 NIP112X812 225072 9 NIP114X9 14216 NIP112X9 14231 NIP2X9 14246 NIP212X9 14260 91/2 10 NIP114X10 30269 NIP112X10 14232 NIP2X10 14247 NIP212X10 14261 101/2 11 NIP114X11 14217 NIP112X11 14233 NIP2X11 14248 NIP212X11 14262 12 NIP114X12 14218 NIP112X12 14234 NIP2X12 14249 NIP212X12 14263 13 NIP114X13 210739 14 NIP114X14 86474 NIP112X14 79994 NIP212X14 67731 15 NIP114X15 83867 16 NIP112X16 210719 NIP2X16 91158 NIP212X16 67732 17 171/2 18 NIP114X18 14816 NIP112X18 14824 NIP2X18 14832 NIP212X18 67733 19 NIP114X19 190331 20 NIP112X20 190334 NIP212X20 67734 21 NIP112X21 90251 NIP2X21 90307 22 NIP212X22 75574 24 NIP114X24 14817 NIP112X24 14825 NIP2X24 14833 NIP212X24 86476 26 NIP114X26 215917 27 NIP2X27 210730 28 30 NIP114X30 14818 NIP112X30 14826 NIP2X30 14834 NIP212X30 200226 36 NIP114X36 14819 NIP112X36 14827 NIP2X36 14835 40 NIP2X40 210732 42 NIP114X42 14820 NIP112X42 14828 NIP2X42 14836 43 NIP112X43 216472 48 NIP114X48 14821 NIP112X48 14829 NIP2X48 14837 53 54 NIP114X54 14822 NIP112X54 14830 NIP2X54 14838 60 NIP114X60 14823 NIP2X60 14839
162
Copper Tubing
11
F.W. Webb offers an inventory reduction program called dealers choice!
The F.W. Webb Heating Catalog
F.W. Webb Company
163 3/23/08 9:51:53 PM
Electrical Meters Digital Multimeters
DM384
DM383B
SECTION
SECTION
12
12 Clamp-On Multimeters
DM383B
DM384
DM5B
The DM383B is a best seller among HVAC and appliance technicians. The new EasyView Display™ makes reading the extra-large 4000count display simple in dark work environment or bright sunlight, plus the range and function indicators provide you with more on-screen information making this a solid value.
The DM384 is full-sized multimeter specifically upgraded to meet the needs of today’s HVAC/R technicians, plant maintenance professionals, and electricians. MIN/MAX capture for unattended monitoring, capacitance for checking run/start capacitors, and frequency for quick verification of generators, inverters, and control circuit operation. The new EasyView Display™ allows for superior viewing in either sunlight or dark work environments.
DM5B offers the functions, ranges and accuracy typically found in full-sized multimeters. The meter, replaceable test leads, and manual are conveniently packaged in a pocket-sized case. Never get caught without a meter again.
Features: • NEW – EasyView Display™. • Measures up to 1000V DC, 750V AC, Amps, Resistance and Continuity. • Diode check function. • 3-3/4 digit, 4000-count display. • MAX capture mode. • Data Hold. • Low battery indication. • On-screen range and function indicators. • Ruggedized to withstand a 10’ drop. • Five year limited warranty.
mfr# Multimeters
description webb#
BPY13 Voltage Detector 1010 Volt Tester 970C E217
Mini Analog
86966
AC Detector
86968
Tester With Probe, 60-500V Low Voltage Tester 5-50V
mfr# DM384 DM383B DM5B
Features: • Auto ranging. • Measures 750 V AC/DC. • Measures AC and DC current to 5 amps. • Test continuity – provides a quick audible tone. • Measures resistance to 30 Megohms. • 3-3/4 digit, 3200 count display with function icons. • Auto power off. • Fuse protected current ranges. • 500 volt input protection on ohm continuity and diode functions. • Low battery indicator. • One year limited warranty.
DL279
DL250
DL49
Features: • 400 Amps AC. • 600 Volts AC and DC. • Resistance to 40 Megaohms. • Continuity. • Capacities to 10,000 microfarads. • Temperature to 750°F (400°C). • .01 µA DC resolution for flame safeguard circuit testing. • Diode check function. • Time-stamped record function. • Autoranging with manual ranging capability. • Data hold. • 13/8” Jaw capacity. • UL and CE listed CAT III. • 3 year limited warranty.
Features: • 400 Amps AC and DC. • 600 Volts AC and DC. • Resistance to 40 kilohms. • Continuity. • Autoranging. • AC Amps peak hold. • Data hold. • 1 mV DC resolution allows use of DMM adapters. • 11/4” Jaw capacity. • UL and CE listed CAT III. • 3 year limited warranty.
Digital Clamp-on Adapters CA383 To enhance your multimeter capacity The CA383 measures AC current only and is compatible with the DM383, DM410, and DM420. • AC Amps 20, 200 or 40, 400 (meter dependent). • Output – Ac Amps, 1mA per 1 A. CA383 mfr# description webb# CA383 Probe Clamp-on AC 189405
Pocket Thermometers 300A
description Webb# Full-Sized Multimeter 152242 Industrial Quality Digital Multimeter 189406 Pocket-Sized Multimeter 242691
These highly functional stick thermometers give you MIN/MAX record capability for unattended monitoring. They have ergonomic 20 degrees tilt heads and pocket-clip stem covers. Features: Accessories: • -58 to 302°F. • Colors: Cherry, Royal Blue, Goldenrod, Smoke, • MIN/MAX record. and Emerald. • Data hold. • Batteries: UEi #AB14. • CE and NSF listed. • Resolution: 0.1 to 199.9°F, 1°F from 200 to 302. • 3 year limited warranty.
86969 86970
12_TestingEquip_p173.indd 164-165
F.W. Webb Company
Webb# 213173 217600
DL49
300A
164
mfr# Description DL279 Digital Clamp-on Multimeter DL49 Digital Clamp-on Multimeter AC/DC
12
TESTING EQUIPMENT
Testers
Features: • NEW – EasyView Display™. • 750 Volts AC and 1000 Volts DC. • 10 Amps AC and DC. • .01 µA DC resolution for flame safeguard circuit testing. • Frequency to 40 Megahertz. • Capacitance to 40,000 Microfarad. • Resistance to 40 Megohms. • Analog bar graph. • Continuity. • Diode check function. • MIN/MAX captures and data hold. • CE listed CAT III. • Five year limited warranty.
Electrical Meters
www.fwwebb.com
The F.W. Webb Heating Catalog
mfr# description webb# 300A Digital Pocket Thermometer 214774
F.W. Webb Company
12
165 3/23/08 9:55:33 PM
Electrical Meters
INF200
SECTION
SECTION
12
12
Electrical Meters
Infrared Thermometers
Carbon Monoxide Detectors
INF185
INF155
CO71
C091
CO100
Features: • 0 to 788°F (-20 to 420°C). • Laser targeting. • Displays MIN/MAX, differential, average and current temperatures. • Nine measurement memory for all five temperature displays. • Backlight. • Switchable °F or °C readings. • Distance to spot ratio of 8 to 1. • Adjustable emissivity from 0.30 to 1.0. • User programmable Hi/Lo alarms. • Low battery indicator. • 1 year limited warranty.
Features: • 0 to 700°F (-18 to 370°C). • Laser targeting. • 7-second auto hold. • Backlight. • Switchable °F or °C readings. • Built-in carrying strap. • Distance to spot ratio of 8 to 1. • Auto power-off. • Low battery indicator. • 1 year limited warranty.
Features: • Measures CO (in ambient) from 0 to 999 ppm. • Tri-color LED indicates concentrations at 3 levels complying with residential and work place standards. • Auto Zero at turn on. • Backlit display. • MAX continually updates highest CO reading. • Audible Alert triggers above 35 ppm indicating dangerous CO concentration. • 3 year limited warranty.
Features: • 0 to 1999 ppm CO. • Internal pump pulls gas samples quickly and steadily. • Flue probe and flexible hose connect easily and securely. • Switchable backlight • Unique pump standby switch extends battery life and speeds testing. • Thumb wheel for easy zero adjust. • Sensor warranted for 2 years. • 2 year limited warranty.
Features: • 0 to 1999 ppm CO. • ±2 ppm or ±5% of reading accuracy. • Resolution, 1 ppm. • Signal output, 1 mV DC = 1 ppm CO. • Response time 90% of reading in 60 seconds. • Duty Cycle, 2000 hours. • Electrochemical sensor. • Low battery indicator. • 1 year limited warranty.
mfr# INF185 INF155
INF150
description webb# Infrared Laser Thermometer 217983 Infrared Thermometer 241307
CO71 C091
Leak and Pressure Detectors
CD200
CD100A
CD100A
EM150
Features: • 50 ppm min. detection. • Long 18” gooseneck for hard to reach areas. • Visual leak detection by color coded LED’s. • Separate user adaptable alarm for predetermined level detection. • Precision sensor detects even the smallest leaks. • “Tip-light” in sensor cap illuminates the search areas. • Adjustable tick rate to locate leaks quickly and easily. • Fast response time of less than two seconds to 40% LEL. • Headphone jack. • 3 year limited warranty.
Features: • 50 ppm min. detection. • Long 18” gooseneck for hard to reach areas. • “Tip-Light” insensor cap illuminate the search area. • Sensor provides accurate detection. • Audio and visual tic rate, fully adjustable. • Headphone jack. • 1 year limited warranty.
Features: • Measures -20° to 20° water gauge (WG). • 0.05” WG resolution below 10” WG. • Integral protective boot. • Easy to use. • Large LCD display. • Automatic zero with manual reset. • Automatic and manual power-off. • Long battery life. • Includes 18” tubing and fitting. • 1 year limited warranty.
mfr# Description CD200 Gas Leak Detector CD100A Combustible Gas Leak Detector EM150 Electronic Manometer
Webb# 217633 217632 193481
mfr# Description CO71 Carbon Monoxide Detector With Alarm C091 CO Gas Analyzer CO100 Digital Carbon Monoxide Multimeter
Webb# 217940 184340 184346
Accessories CO100
mfr# Description Webb# TA1K Single Input Temperature Adapter 184335
ATT29 K-Type Temperature Probe 184323 ATT36 8” Surface Probe With Handle 221152
ATL55
Multimeter Test Leads
TESTING EQUIPMENT
EM100A
CD200
221047
Electrical Tester MA1 The MA1 is a high sensitivity direct reading AC ammeter. it is designed to simplify the setting of oil and gas heat anticipators. Features: • Ranges: 0-1.2 AC Amps. • Accuracy: ±3% of full scale. • 1 year limited warranty. mfr# MA1
MA1
166 12_TestingEquip_p173.indd 166-167
F.W. Webb Company
12
description webb# AC Ammeter 57341
www.fwwebb.com
12
The F.W. Webb Heating Catalog
F.W. Webb Company
167 3/23/08 9:55:51 PM
Electrical Meters
SECTION
SECTION
12
12
Electrical Meters
Current Clamp
Analog/Digital Multimeters
801400
179
AC Current clamp with safety shrouded banana plugs for multimeters. Measure ac current from 1A to 400A. Output to meter is 1 mA/A. Frequency response: 48Hz to 1000 Hz. Maximum conductor size: one 30 mm (1.18”) or two each 25 mm (0.98”).
Features: • 6000 count resolution. • 0.09% accuracy. • MIN/MAX average. • True-rms, AC voltage and current.
Model# Description 80I-400 400 amp Current Probe
Webb# 94311
80PK-22 Immersion Probe • Type-K thermocouple for use in liquids and gels. • Measurement range: -196 to 1090°C (-320 to 1994°F). • Accuracy: ±4% (-196 to -110°C), ±4.4°C (-110 to -40°C), ±2.2°C (-40 to 275°C), ±0.75% (275 to -1090°C). Model# Description 80PK22 Immersion Thermocouple Probe
179
Webb# 94313
• Converts a DMM to a thermometer. • For use with type-K thermocouples in low voltage applications. • Measurement range: -50 to 1000°C (probe dependent). • Accuracy: 2.5% ±2°C (-50 to -20°C), 0.5% ±2°C (-20 to 350°C), 1.75& ±2°C (350 to 500°C), 2% ±2°C (500 to -1000°C).
Webb# 94318 94319 166138
335A & 333A • Large, backlit display (on the 335) is easy to see. • Auto shut-off maximizes battery life so the meter works when you need it. • In-rush current function (on the 335) for measuring starting current for motors, lightening, etc. • Small body and jaws fit perfectly in your hand and into tight places. • Improved low current measurements accuracy from new microprocessor technology. • Meter controls are positioned so current measurements can be done with one hand. • Handy display hold keeps measurements on the display.
Webb# 94316
• Type-K thermocouple for fast temperature and superheat measurements of pipe surfaces. • Durable ribbon sensor. • Measurement range: -29 to 149°C (-20 to 300°F) for pipe diameters from 6.4 to 34.9mm (1/2” to13/8”). • Accuracy: 1.9°C over measurement range. Webb# 95549
335
Model# Description 335A 600 amp Clamp Meter 333A 400 amp Clamp Meter
Webb# 94317 94324
TESTING EQUIPMENT
Model# Description 80PK-8 Type K Pipe Clamp
• Sleep mode – 30 minutes. • IEC 61010 rating– CATIII – 1000V. • Battery access door the enables changing batteries without breaking the calibration seal.
Clamp Meters
80PK-8 Pipe Clamp Temperature Probe
80PK-8
Features: • 0.05% + 1 basic DC accuracy. • Backlit display with larger digits. • MIN/MAX Mode. • True-rms. • Peak MIN/MAX – 250 µSec. • Relative mode. • Diode test. Model# Description 179 True-rms Multimeter With Holster 87-5 True-rms Multimeter FLK116 Multimeter Thermometer
87-3
80TK Thermocouple Module
Model# Description 80TK Thermocouple Module
• CAT IV rated, easy access door. • Backlight. • Lifetime warranty.
87-5
Contact Probes
80PK-22
12
F.W. WEBB CARRIES THE COMPLETE LINE OF 90% AFUE FURNACES. 168 12_TestingEquip_p173.indd 168-169
F.W. Webb Company
www.fwwebb.com
12 The F.W. Webb Heating Catalog
F.W. Webb Company
169 3/23/08 9:56:05 PM
Electrical Meters
SECTION
SECTION
12
12
Electrical Meters
Test Leads & Probe Sets
Digital Thermometers
TL220 Industrial Lead Set
52 Series II
• One pair each of TL22 silicone test leads, AC 20 heavy duty alligator clips and TP20 sharp industrial test probes. • Category III, 1000V, 10A rating.
The Fluke 52 is the most advanced, yet affordable, handheld thermometer in the industry. The Fluke 52-2 offers high accuracy, high performance and simple operation. Features: • Number of inputs — Dual. • MIN/MAX/AVG recording with • Rugges design with holster. time stamp. • Splash/dust resistant. • Differntial (T1-T2) readout. • Dual display with backlight.
TL75 Hard Point Test Lead Set • One pair (red,black) comfort grip probes with PVC insulated test leads with right angle shrouded banana plugs. • Recommended for general purpose measurements. • Category III, 1000V, 10A rating, UL listed. TL220
mfr# Description TL220 Industrial Test Lead Set TL75 Test Lead Set TL75
Webb# 94330 94331
Fluke 16 Multimeter with Thermometer Three tools in one: Thermometer, flame rod tester with microamp function, and multimeter with capacitance. Includes an 80PK-1 bead probe thermocouple and an 80AK temperature memory. Features: • Accurate temperature measurement from -40 to 750°F (-40 to 400°C). • Capacitance up to 10,000 microfards. • MIN/MAX recording with relative time stamp records the highest and lowest voltage readings during 100-hour period. • High resistance ranges to 40 megohms.
52 Series II
AC70A Alligator Clips • Slide-on alligator clips for test probes with 1.93mm to 2.13mm long tips. • Gold-plated jaws provide 8mm opening. • Catagory III, 600V, 10A rating.
Alligator Clip
Model# Description AC72 Alligator Clip AC76A
Fluke 61 Infrared Thermometer
Webb# 166140 Fluke 16
Electrical Testers Fluke 7 Series The economical Fluke 7 series is ideal for first-level electrical troubleshooting. The compact design and slide switch offer one-handed operation. Features: • 4000 count digital display. • Auto selection simplifies voltage measurements in power environments. • Automatic readings of volts AC (600V). • Automatic readings of volts DC (600V). • 400 Ohm range/continuity beeper. • TL75 test leads included with meter. • High visibility yellow plastic housing make it easy to locate on the job or your toolbox.
Volt Alert
Model# Description 52-2 Thermometer 16 Thermometer, Multimeter 61 Infrared Thermometer
12_TestingEquip_p173.indd 170-171
Webb# 94325 166138 251580
Fluke 61
VoltAlert™
Amp-Master Thermostat Circuit Meter
VoltAlert™ AC voltage testers from Fluke are easy to use – just touch the tip to a control wire, conductor, or outlet. When it glows red, you know there’s voltage in the line. Electricians, maintenance, service, safety personnel and home owners can quickly test for energized circuits and defective grounds on the factory floor, in the shop, or at home. Model# Description 7-600 Electrical Tester 1AC-A1-11 Voltage Meter Detector
T80W Precisely measures thermostat control circuit current to allow correct setting of the heat anticipator. Avoids repeat service calls to remedy short cycling or override problems. Connects at either the thermostat or relay. Features: • Accurately measures thermostat control circuit draw to correctly adjust heat anticipator setting. • Meter dial matches T87F heat anticipator scale. • “Service Truck Tough” with high impact case.
Webb# 155271 155269
T80W
170
The newest addition to the Fluke family of temperature products is the Fluke 61. This infrared thermometer is the ideal tool for measuring surface temperature of rotating, hard-to-reach, electrically live, or dangerously hot targets. Features: • Bright laser beam provides easy targeting. • Display clearly supplies data at a glance. • Shock-absorbing holster increases ruggedness. • 0.2°C (0.5°F) resolution. • Backlight illuminates the screen in the dark. • Automatic sleep mode after 7 seconds extends battery life.
F.W. Webb Company
www.fwwebb.com
TESTING EQUIPMENT
Fluke 7 Series
12
Model# Description T80W Low Voltage Tester
The F.W. Webb Heating Catalog
Webb# 69695
F.W. Webb Company
12 171 3/23/08 9:56:30 PM
Combustion Testing Accessories
PCA 25
Fyrite Pro
Oil Burner Combustion Kit
Fyrite
SECTION
SECTION
12
12
Bacharach
Pump Testers
Smoke Candles
Combustion and Environmental Analyzers
T10W
Generate smoke by chemical reaction. it eliminates costly equipment & time consuming operations by pinpointing leaks. Smoke tests will effectively and inexpensively reveal leaks and other faults in heating and air conditioning duct work, furnaces, tanks, piping, and sewerage/waste collection systems.
mfr# 24-8043
description webb# Combustion Analyzer, PCA 25 155163
24-8205
Fyrite® Pro 125 Tester With Printer
10-5022 T42W 10-5064 11-0071 10-5030 11-0021 10-5060 T50-2W T50-3W 11-7032 T50-4W 13-7019 13-3000 17-7002 17-0026
Oil Burner Combustion, Utility Testing Kit Tempoint Thermometer, 1000°F, (6” Stem) Fire Efficiency Finder Efficiency Fire Finder With Oil Gas Burner Combustion, Utility Testing Kit Fyrite Diaphragm Fluid Oxygen Bottle, 3 Pack PurePro CO2 Tester Repair Kit PurePro CO2 Tester Recharging Kit CO2 Indicator PurePro CO2 Indicator Fluid, 0 - 60% MZF Draft Gauge, Remote, +0.05 to 0 to -025”W Draftrite Pocket Gauge, +0.10 to 0 to -014”W Manometer Manometer Case
Precisely sets pump pressure and checks cut-off with accuracy not possible using non-liquid gauges. Gauge liquid dampens pulsation allowing precise measurement and cutoff test with just the turn of the knob — no disconnecting! “Service Truck Tough” carrying case with complete instructions. • Quick-connect fittings require only finger tightening. • Brass construction with color coded hoses. • Fits popular 3/16” and 1/4” nozzle line fittings. • Stainless steel liquid filled gauge, range 0-300 PSI. • Easy-to-follow instructions – rugged carrying case.
247726 68938 68923 68943 85022 68939 68912 68942 68917 68918 68919 68941 68913 68920 68924 68925
mfr# description webb# T10W Pump Tester Kit 253697
mfr# EM200
description webb# Duel Input Manometer 284231
Smoke Tester — Polycarbonate Barrel
Manometer
Features: • Virtually unbreakable polycarbonate barrel. • Hardware all brass and stainless steel. • Sampling tube hooks into smokepipe. • Fits into Brigon and Bacharach cases. • Lifetime silicone lubrication. mfr# T40W T40-1W
T40W
description webb# Smoke Test Set 68921 Smoke Test Paper 68922
T15W
description webb# Suction Line Analyzer #2 Oil 253698
Pressure & Vacuum Gauges mfr# S100-500 48363 165296 Riello 3001023 7050010
description webb# Sling Psychometer, +25°F + 120°F Mercury Filled 68945
Safety Monitors and Detectors mfr# 19-8004 24-7070
mfr# T15W
Indoor Air Quality mfr# 12-7011
Suction Line Analyzer
description webb# Vacuum Gauge, 1/8 0-30 75587 Pressure Gauge, 0-300psi, 1/8 155222 Vacuum Gauge Liquid Filled 0-30 253503 R35 Vacuum Gauge R35 Pressure Gauge
description webb# Monoxor® II CO Analyzer With Case 68915 Replacement O2 Sensor 68931
90760 90761
mfr# Description 41900 30 Second – 12/pk. 41901 60 Second – 12/pk.
# cu. ft. webb# 4,000 69678 8,000 69679
Hole Plugs Fits hole in flue pipe after sample has been taken. Designed for 5/16” holes that accomodate Lynn Combustion Efficiency Analyzer Probe. mfr# 6010
description webb# 100 per package 213991
Heating System Evaluation Forms A two-part carbon form listing all necessary check-points for a complete evaluation. One part is for company records and one part can be left with the customer. mfr# 6008
description webb# 50 per package 70265
Dial Thermometers mfr# description webb# Threaded Connection 1449 With 1/2” MIP Well 87133 1449C 1/2” Well Only 87135 Sweat Connection 1450 With 3/4” Sweat Well 75534 1450W 3/4” Sweat Well Only 243272
TESTING EQUIPMENT
Sling Psychrometer
Analyze suction line problems (ie. air leaks, restrictions, dirt, etc.) using this clear tubing service tool. Vacuum gauge liquid dampens pulsation allowing precise measurement and protects gauge from hydraulic shock damage. Actually see what’s happening inside that problem suction line! • Thick wall clear tubing withstands vacuum – does not collapse. • Brass construction with stainless steel tubing clamps. • Fits popular 3/8” and 11/2” suction line fittings. • Gauge range 0 – 30” Hg. • Easy-to-follow instructions.
UEI Electronic Manometer
MZF Draft Gauge
Oil Burner Testing
Boiler Pressure Testing Gauge • Plastic face. • Supplied with protective filter washer. • 3/4” FHT brass swivel connection. mfr# description webb# 1423 0-160# psi Water Test Gauge 75294 Adapter for Water Test Gauge 1402 Hose X 1/4” Adapter 91070
Monoxor II
Leak Detection Leakator 10
172 12_TestingEquip_p173.indd 172-173
mfr# 19-7051
12
description webb# Leakator® 10 Kit, Complete With Case 80817
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
173 3/23/08 9:57:39 PM
Low Voltage Thermostats
SECTION
SECTION
13
13
Low Voltage Thermostats Heating and Cooling Thermostats
T87K, T87N — The Round
200 Series
The Round T87K and T87N thermostats provide electronic control of 24Vac heating and cooling systems with the classic twist to set dial. • Mercury Free. • Classic Styling. • Premier White®. • Separate temperature setting and thermometer. • The T87K heat only works with 2 or 3 wire heat only systems. • The Easy-To-See has enlarged scale and raised numbers—plus it clicks at every 2ºF change.
The 200 Series Thermostats are designed and engineered for outstanding performance. 200 Series Thermostats are mercury free and environmentally safe. Their unique hermetically sealed-in-glass switch design requires no leveling and provides optimum protection from contamination. Decorative Wall Plate is included with all models to cover old thermostat mounting marks.
®
®
T87K
Setting Temperature Range: 40ºF to 90ºF. MFR#
Application
200 Series
stages
Comments
includes
T87K1007 Heat only gas or oil systems
1 Heat
—
—
T87N1000 Heating and cooling systems
1 Heat/1 Cool
—
—
1 Heat/1 Cool
Easy-To-See model with large raised markings and a click at each 2º setpoint change
6 in. (152 mm) cover ring and switch position labels
T87N1026 Heating and cooling systems
webb#
32-623-050
200-402
32-583-050 32-741-850
200-502
32-571-850
316293
Special Energy-Conserving Model
316294
webb# 360312
S483 Used as a freeze warning device. Completes circuit to household lamp on temperature fall, indicating inoperative heating equipment. • Plugs directly into wall outlet. • Lamp plugs into receptacle at bottom of Winter Watchman device. • Not precision calibrated for use as a thermostat. • Useful when house is unoccupied to notify a neighbor of a temperature drop. so heating source fault can be rectified before freeze-up occurs. mfr# MOUNTING sensor element Switching Action Color webb# S483B1002 Vertical Bimetal SPST Beige 35053
200-403
32-623-051
200-503
32-741-851
13_Thermostats_p190.indd 174-175
www.fwwebb.com
application
heat anticip. range
2 Wire 24 Volt Heating
.18 to 1.0 AMP
2 Wire Millivolt Heating
None
2 Wire 24 Volt Heating
.18 to 1.0 AMP
186647
2 Wire Millivolt Heating
None
192850
SPST
SPST
webb# 178928 186646 85415 192849
Replacement Subbases
400/405 Series thermostats are mercury free and environmentally safe. Their unique hermetically sealed-in-glass switch design requires no leveling and provides optimum protection from contamination. The basic 400/405 thermostat can be used as a heating only, cooling only, or zone system thermostat, depending upon how the subbase is wired. The 400/405 Series thermostats, when used with the 490/495 Series Universal Switching Subbase, will replace most heating/cooling applications. Decorative Wall Plate is included with all models. It can be used to cover old thermostat mounting marks. mfr#
System switch functions
fan switch functions
application
webb#
400-400
48° F to 86°F
24 Volt Heat/Cool
.18 to 1.0 Amp
188516
mfr#
System switch functions
fan switch functions
application
webb#
490-400
Heat-Off-Cool
Auto-On
Universal
186739
9200 Series The New 9200 Series Low Voltage Thermostats combine the reliable sealed-in-glass mercury switch with the latest design technology contemporary looks in vertical and horizontal models. No subbase is required and they will mount directly to the wall or on a standard junction box. mfr#
DIAL temp range
application
9200H
SPDT
24 Volt Heat/Cool
SPST
2-Wire Millivolt or 24 Volt
9204H
F.W. Webb Company
39°F to 75°F
switch action
400/405 Series
Winter Watchman
174
48°F To 86°F
316292
400/405 Series
S483
factory#
200-501
Accessories MFR# Description 50010944-001 Range Stop T87K, N
mfr# 200-401
dial temp. range
13 thermostats
24 Volt Thermostats
The F.W. Webb Heating Catalog
heat anticipation range
webb# 146034
.02 to 1.6 Amps
155175
F.W. Webb Company
175 3/24/08 11:44:22 AM
SECTION
SECTION
13
13
Line Voltage Thermostats
Line Voltage Thermostats Medium Duty Line Voltage Thermostat
MLV2 Line Voltage Heating Thermostat
T651
Features: • Single or double pole applications. • UL listed. Compatible With: • Baseboard, ceiling cable, or other radiant heat applications. Electrical Ratings: For 120/240V systems up to 22 Amps. Temperature Control Range: 45ºF to 90ºF (7º to 32º). Accuracy + 1ºF over a range of 50ºF to 95ºF. MFR# Description MLV2 Line Voltage T-Stat
Mfr#
Color
T651A2028
Brushed champagne gold and dark pewter faceplate; beige and brown case.
T651A
webb# 320352
Operating Temperature Range
35ºF to 95ºF
Includes
Use With
Webb#
Locking cover screw; thermometer; vertical, horizontal and balnk faceplates; wall plate and adjustable range stops
Q473A, B
30230
13 thermostats
Control Line voltage valves, motors, contactors, electric heat, elements, duct furnaces, and fan coil units in heating/cooling systems. • Automatic cooling and heating anticipation. • Mount on standard vertical or horizontal outlet box.
Heavy Duty Line Voltage Thermostats T6051, T6052 Used to control fan coils, fans, motor starters, valves, contactors, and circular motors in heating and/or cooling systems. • Provide good line voltage comfort control. • Use with Q651A,B subbase for system and fan switching. • Removable setpoint knob locks setpoint and prevents tampering. • With locking cover.
Line Voltage Wall Thermostat (Heating and Cooling) T26 For line voltage control of residential, commercial, or industrial heating or yearround air conditioning. Heat or cold anticipators are not required. The liquid-charged temperature sensing element and highly efficient diaphragm and leverage provides close temperature control. • Attractive beige colored, high-impact plastic enclosure. • Close differential without the need for anticipators. • Bimetal thermometer supplied as standard except where indicated. • Equipped with adjustable dial stops. T26
TYPE OF Selector mfr# Adjustment application Switch T26S-18C Knob SPDT None
T6051
webb# 103864
Mfr#
Application
Operating Temperature Range
Switching Action
T6051A1016
Heating and cooling
50ºF to 80ºF
SPDT
T6052A1015
Two stage heating or two stage cooling
46ºF to 84ºF
2 SPDT switches
Includes
Use With
Locking cover Q651A, B subbases Horizontal for system mounting and fan adapter switching
Webb# 85849 106257
Electric Heat Thermostats T498 Provide line voltage control of electric heating systems. • Easy to install; color-coded leads. • Include thermometer. • Include long-lasting Micro Switch™ mechanism; makes on temperature fall. • Rugged, plastic mounting base. • Mount on standard 2” X 4” outlet box or 4” X 4” junction box.
F.W. Webb is the exclusive distributor of trim kits for time-saving installations.
T498 Mfr# T498A1778 T498A1810 T498B1512 T498B1553
176 13_Thermostats_p190.indd 176-177
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
Switching Action STST
DPST
Includes
Webb#
Range stops, locking cover and extra knob decal for recalibration
99655
—
99991
Thermometer, range stops, locking cover and extra knob for recalibration, Positive OFF
97766
Positive OFF, makes double line break with setting dial in OFF position
98242
F.W. Webb Company
177 3/24/08 11:44:24 AM
Digital Thermostats
SECTION
SECTION
13
13
Digital Thermostats
Digital Non-Programmable Thermostats
Non-Programmable Thermostats
SWITCH POSITION
Compatible With: • Most 24V gas, oil, and electric heating systems. • 2 wire hydronic systems. • Millivolt systems. • Hydronic air handlers. Temperature Control Range: • 45ºF to 90ºF (70º to 32º)
T8400
MFR# Description D110 Heating Only
webb# 314729
color
System
FAN
Webb#
Premiere White
HEAT-OFF
NONE
246656
T8400C1008
Heating & cooling systems
Taupe
OFF-HT-COOL
AUTO-ON
251834
T8400C1099
Heating & cooling systems
Premiere White
OFF-HT-COOL
AUTO-ON
253428
T8775A, T8775C
Features: • Electronic accuracy. • Can be mounted horizontally or vertically. • Large, easy-to-read digital display. • EL (electro luminescent) backlight. • System or battery powered, 2 “AA” batteries included. • Low battery indicator. • Decorative wall plate is available. Compatible With: • Most 24V gas, oil, and electric heating and cooling systems. • 2 wire hydronic systems. • Millivolt systems. • Hydronic air handlers.
Application Heat only systems
The Digital Round™ Non-Programmable Thermostats
D210 Heating Thermostat
D210
Mfr# T8400B1018
thermostats
Electronic Thermostat provide temperature control for 24V heating/cooling systems. • Large display for quick easy readability. • Manual changeover from heat to cool eliminates unexpected system operation. • Selectable heating cycle rate for a variety of applications. • Setpoints are permanently held in memory (no batteries used) and retained during power outages.
Features: • Electronic accuracy. • Universal decorative wall plate is available. • Vertical style. • Large, easy-to-read display. • Universal replacement. • Low battery indicator.
D110
13
T8400 Electronic Thermostat
D110 Heating Thermostat
The T8775A Thermostat provides 24V control of heating only systems. The T8775C Thermostat provides single-stage temperature control for 24V heating-cooling systems with manual changeover from heat to cool. • Attractive styling complements any decor. • Large easy-to-read display. • The temperature reading is easily seen from a distance. • Backlit display. • No batteries required. • Powered through heating-cooling system controls.
T8775A
MFR# Description webb# D210 Heating Only 364078 Vertical/Horizontal Mounting
MFR#
Application
stages
setting temperature range (F)
WEBB#
T8775A1009 24 Vac gas or oil heat only systems
1 Heat
Heat: 40ºF to 90ºF
264102
T8775C1005 24 Vac gas, oil and electric heating with cooling, including 1 heat/1 cool heat pumps
1 Heat/ 1 Cool
Heat: 40ºF to 90ºF; Cool: 45ºF to 99ºF
264103
D111 Heating & Cooling Thermostat
D111
Features: • Electronic accuracy. • Can be mounted horizontally or vertically. • Large, easy-to-read digital display. • EL (electro luminescent) backlight. • System or battery powered, 2 “AA” batteries included. • Low battery indicator. • 5 or 2 minute compressor delay. • Decorative wall plate is available.
PRO 3000 Basic Non-Programmable Thermostats
Compatible With: • Most 24V gas, oil, and electric heating and cooling systems. • 2 wire hydronic systems. MFR# Description webb# • Millivolt systems. D111 Heating/Cooling 241267 • Hydronic air handlers. Vertical/Horizontal Mounting • Single stage heat pumps.
The PRO series provides non-programmable thermostats for 24 Vac conventional and heat pump systems or 750 mV heating systems. • Non-programmable digital thermostat. • Backlit digital display – both current and set temperatures are easy to read in various lighting conditions. • Basic operation – easy-to-use slide switches allow you to select the heat or cool mode, and operate the fan. Setting Temperature Range: Heat: 40ºF to 90ºF; Cool: 50ºF to 99ºF Mounting: Horizontal Switching Positions MFR#
Application
Color SYSTEM
TH3110D1008 1 Heat/1 Cool Conventional Premier and Heat Pump White®
178 13_Thermostats_p190.indd 178-179
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
Fan
COOL-OFF-HEAT AUTO-ON
Stages 1 Heat/1 Cool
F.W. Webb Company
WEBB# 359670
179 3/24/08 11:44:27 AM
Digital Thermostats
SECTION
SECTION
13
13
Digital Thermostats
FocusPRO™ 5000 Digital Non-Programmable Thermostats
Deluxe Digital Non-Programmable Models
The FocusPRO™ non-programmable digital thermostat provides electronic control of 24 Vac conventional and heat pump systems or 750mV heating systems. • Non-programmable digital thermostat • Large, clear backlit display – easy to read in various lighting conditions • Display size options – available in large screen or standard • Easy change battery door – flip out door allows for easy battery replacement without removing or disassembling the thermostat Setting Temperature Range: Heat: 40ºF to 90ºF; Cool: 50ºF to 99ºF Mounting: Horizontal 300-204
Switching Positions MFR#
Application SYSTEM
Fan
WEBB#
mfr# 300-201 300-203 300-204 300-206
APPLICATION 1 Heat / 1 Cool 2 Heat / 2 Cool Gas Electric Heat Only 1 Heat / 1 Cool
webb# 167348 107584 167346 96833
Stages
Comments
TH5220D1003 Heating and cooling systems
HEAT-OFF-COOL- AUTO-ON AUTO-EM, HEAT
Up to 2 Heat/2 Cool
Standard Display
367581
TH5220D1029 Heating and cooling systems
HEAT-OFF-COOL- AUTO-ON AUTO-EM, HEAT
Up to 2 Heat/2 Cool
Large Display
367580
TH5320U1001 Heating and cooling systems
HEAT-OFF-COOL- AUTO-ON AUTO-EM, HEAT
Up to 3 Heat/2 Cool
Large Display
367992
9500
TH5110D1006 Heating and cooling systems
HEAT-OFF-COOL- AUTO-ON AUTO
Up to 1 Heat/1 Cool
Standard Display
306203
TH5110D1022 Heating and cooling systems
HEAT-OFF-COOL- AUTO-ON AUTO
Up to 1 Heat/1 Cool
The 9500 Series are the clear alternative to traditional mechanical thermostats. The modern design allows attractive and consistent temperature control.
Large Display
283539
Economy Thermostat
13 thermostats
The line of Deluxe Digital Thermostats offers state-of-the-art control in a stylish, slimline package with an easy-to-read LCD display. Designed for residential or commercial needs, these new models will handle single stage, multistage or heat pump applications. All models provide automatic changeover, a day/night button for an alternate temperature setting and remote sensing capability. They also provide short cycle protection during normal operation, a keypad lock and a cover lock.
Accessories mfr# description 10-528 Indoor Sensor 10-529 Remote Outdoor Sensor
9500
mfr# 9500 9505 9520
webb# 106402 167354
description/Applications Digital, 24V, 1 Heat / 1 Cool Gas / Electric Systems Millivolt Compatible, 1 Heat / 1 Cool Gas / Electric Systems, Single Stage Heat Pumps Digital Heat Pump, 2 Heat / 2 Cool, Heat Pump Systems
webb# 112206 222415 222415
Accessories mfr# description 10-528 Indoor Sensor 10-529 Remote Outdoor Sensor
F.W. Webb stocks energy saving products!
180 13_Thermostats_p190.indd 180-181
F.W. Webb Company
www.fwwebb.com
webb# 106402 167354
F.W. Webb stocks Rinnai Continuums and the complete line of heaters!
The F.W. Webb Heating Catalog
F.W. Webb Company
181 3/24/08 11:44:29 AM
Programmable Thermostats
SECTION
13
13
Programmable Thermostats
Programmable Thermostats
Programmable Thermostats
DP511 Digital Programmable 5-2 Heating & Cooling Thermostat
DP711TS Digital Programmable 7 Day Touch Screen Heating & Cooling Thermostat
Features: • Energy Star certified. • Separate programs for weekdays and weekends. • Preprogrammed – up to 4 programs per day. • Separate programs for heating and cooling. • Either system powered with battery backup or battery powered, (2) “AA” batteries included. • Large lighted liquid crystal display. • 5 minute air conditioning compressor. • Temporary and constant temperature override. • Total isolation between system power and thermostat. • Keyboard lockout. Compatible With: • Most single stage 24V gas, oil, electric heating and air conditioning systems, including single stage heat pumps. • 2 wire hydronic systems. • Hydronic air handler systems. Temperature Control Range: • 45ºF to 90ºF Program Settings: • 4 preset programs per day heating and cooling. All may be easily reprogrammed in 1º and 15 minute increments with programming dial. Circuit Protection: • Circuit protection is built-in, no isolation relays required.
Features: • 7 Day Programming – 4 Periods Per Day. • Smart Recovery. • Default ENERGY STAR® Approved Program. • Lighted Display. • Hold Button. • Touch Screen Lockout Code. • 2 or 5 Minute Delay. • Temporary Temperature Override. • Filter Monitor. Compatible With: • Low Voltage (24 Volt) Systems. • Single Stage Heat Pumps. • High Efficiency Systems. • Millivolt Systems (Wall Furnace). • Single Stage Heating and Cooling Systems. Temperature Control Range: • 45ºF to 90ºF
DP711TS
DP722 Digital Programmable 7 Day Heating & Cooling Thermostat With Universal Compatibility
DP711 Digital Programmable 7 Day Heating & Cooling Thermostat
DP711
182 13_Thermostats_p190.indd 182-183
Features: • Energy Star certified. • Preprogrammed – up to 4 programs per day. • Separate programs for heating and cooling. • Battery powered, (2) “AA” batteries included. • 5 minute air conditioning compressor delay. • Temporary and constant temperature override. • Display illuminates at the touch of light button. • Program lock feature. Compatible With: • Most 24V gas, oil, electric heating and air conditioning systems. • 2 wire hydronic systems. • Millivolt systems. • Single stage heat pumps. • Hydronic air handler systems. Temperature Control Range: • 45ºF to 90ºF
F.W. Webb Company
DP722
www.fwwebb.com
13 thermostats
DP511
SECTION
Features: • Controls up to 2 Stages of heating and cooling plus auxiliary and emergency heat. • ENERGY STAR Compliant, Default ENERGY STAR approved program. • Auxiliary and emergency heat indicators. • IAQ independently programmable fan. • 4 periods per day. • Decorative wall plate is available for thermostat. • Optional smart recovery. • Multimode keyboard lockout with user programmable 3 digit code. • Programmable high and low setting limits. • Dual power capable (system/battery). • Programmable fan delays for heat, cool, in both on and off. Compatible With: • Most 24V Gas, Oil, Electric Heating and Air Conditioning Systems. • Multi-stage Heat Pumps. • 2 Wire Hydronic Systems. • Hydronic Air Handlers. • Millivolt Systems. Temperature Control Range: • 45ºF to 90ºF
The F.W. Webb Heating Catalog
F.W. Webb Company
183 3/24/08 11:44:31 AM
Programmable Thermostats
SECTION
SECTION
13
13
DPH521 Programmable 5-2 Heat Pump Thermostat
Pro 4000 5-2 Programmable Thermostat The PRO series provides programmable thermostats for 24 Vac conventional and heat pump systems or 750 mV heating systems. • Weekday/Weekend programming – 5-2 (Weekdays, Weekends) programming to fit your lifestyle. • Backlit digital display – both current and set temperatures are easy to read in various lighting conditions. Setting Temperature Range: • Heat: 40ºF to 90ºF
FocusPro™ 6000 5-1-1 Day Programmable Thermostat The FocusPRO™ programmable thermostat provides electronic conrol of 24 Vac conventional and heat pump systems or 750 mV heating systems. • Weekday/Weekend programming – use as 5-1-1 (Weekdays, Saturday, Sunday) or 5-2 (Weekdays, Weekend) programmable thermostat, whichever best fits your lifestyle. • Large, clear, backlit display – easy to read in various lighting conditions. • Display size options – available in large screen or standards. • Adaptive Intelligen Recovery™ – ensures programmed temperature is reached by programmed time. • Temperature range stops – prevents user from setting the temperature too high or too low. Setting Temperature Range: • Heat: 40ºF to 90ºF; Cool: 50ºF to 99ºF Switching Positions MFR#
Stages
COMMENTS
WEBB#
TH6110D1005 HEAT-OFF-COOL-AUTO AUTO-ON
Up to 1 Heat/1 Cool
Standard Display
362718
TH6110D1021 HEAT-OFF-COOL-AUTO AUTO-ON
Up to 1 Heat/1 Cool
Large Display
308152
TH6220D1002 HEAT-OFF-COOLAUTO-EM. HEAT
AUTO-ON
Up to 2 Heat/2 Cool
Large Display
36784
TH6220D1028 HEAT-OFF-COOLAUTO-EM. HEAT
AUTO-ON
Up to 2 Heat/2 Cool
Large Display
367583
Application
SYSTEM
Fan
Setting Temperature Range: • Heat: 40ºF to 90ºF; Cool: 50ºF to 99ºF Switching Positions
Stages
WEBB#
MFR#
13_Thermostats_p190.indd 184-185
SYSTEM
TH4110D1007 1 Heat / 1 Cool Conventional and Heat Pump
COOL-OFF-HEAT
AUTO-ON
1 Heat/1 Cool
245718
TH8110U1003 HEAT-OFFCOOL-AUTO
TH4210D1005 2 Heat / 1 Cool Heat Pump
COOL-OFF-HEAT- AUTO-ON EM. HEAT
2 Heat/1 Cool
367579
TH8320U1008 HEAT-OFFCOOL-AUTO
F.W. Webb Company
Fan
Features: • Menu Driven Programming Guides you through the scheduling process, showing only necessary information and choices on each screen. • Ability to Select Multiple Days allows you to easily customize the thermostat for you unique schedule. • Multiple HOLD options allows you to service or replace the air filter, humidifier pad, ultraviolet lamp or thermostat batteries.
TH8321U1006
184
SYSTEM
VisionPro® 8000 Touchscreen 7-Day Programmable Thermostat
Switching Positions MFR#
13 thermostats
Features: • Energy Star certified. • Separate programs for weekdays and weekends. • Preprogrammed – up to 4 programs per day. • Separate programs for heating and cooling. • Either system powered with battery backup or battery powered, (2) “AA” batteries included. • Lighted display with large liquid crystal display. • 5 minute air conditioning compressor delay. • Temporary and constant temperature override. • Total isolation between system power and thermostat. • For 2 stage heat pump applications. • Includes second stage and emergency heat indicator. Compatible With: • Most single stage 24V gas, oil, electric heating and air conditioning systems, including single stage heat pumps. • 2 wire hydronic systems. • Millivolt systems. • Hydronic air handler systems. Temperature Control Range: • 45ºF to 90ºF Program Settings: • 4 preset programs per day heating and cooling. All may be easily reprogrammed in 1º and 15 minute increments with programming dial. Circuit Protection: • Circuit protection is built-in, no isolation relays required.
Programmable Thermostats
www.fwwebb.com
The F.W. Webb Heating Catalog
HEAT-OFFCOOL-AUTO
Fan
Stages
COMMENTS
AUTO-ON
Up to 1 Heat/ 1 Cool
Selectable to Heat Only or Cool Only
268716
AUTO-ON
Up to 3 Heat/ 2 Cool
Conventional and heat pump systems. The L terminal is an input or output.
283540
AUTO-ON
Up to 3 Heat/ 2 Cool
Includes Dehumidfication Control. Conventional and heat pump systems. The L terminal is an input or output.
283039
F.W. Webb Company
WEBB#
185 3/24/08 11:44:34 AM
Programmable Thermostats
SECTION
SECTION
13
13
Programmable Thermostats Robertshaw
9700i Deluxe Programmable Thermostat
Deluxe Programmable Models
1 Heat / 1 Cool The 9700i is compatible with all standard 24 Volt AC heating/cooling systems, and requires only four wires for standard installation. • Menu Driven (Ease of Programming). • 5/2 Day Programming. • 7 Day Programming. • Large Display.
The line of Deluxe Programmable Thermostats offer state-of-the-art control for residential and commercial applications. Designed for new construction or replacement applications, these models feature 7 day programming with the choice of 2 or 4 program periods per day, a key-pad lock, a cover lock, and optional remote indoor and outdoor temperature sensors. They also include as standard features automatic changeover, permanent program memory retention during any type of power outage, and a smart fan option that can run the fan continually during occupied periods, which is a requirement in many commercial applications.
mfr# STAGING / Application 9700i 1 Heat / 1 Cool / Gas, Electric Systems, Heat Pump
webb# 260855
9701i Deluxe Programmable Thermostat
300
1 Heat / 1 Cool The 970i is compatible with all standard 24 Volt AC heating and cooling systems. • Menu Driven (Ease of Programming). • 5/2 Day Programming. • 24 Hr. Programming. • 7 Day Programming. • Large Display. • Back Lighting. mfr# STAGING / Application 9701i 1 Heat / 1 Cool / Gas, Electric Systems, Oil, Heat Pump
mfr# 10-528 10-529
webb# 250685
1 Heat / 1 Cool The 9801i series thermostats contain all the features and benefits of the award-winning 9700i series, including our simple, menu-driven programming that’s similar to a cell phone. Humidity and temperature control in one easy-to-install, easy-to-program package. The 9801i is compatible with all standard 24 Volt AC heat pump system, up to two stage heat and two stage cool. • 5/2 Day Programming. • 7 Day Programming. • Manual Humidity Control. • Automatic Humidity Control based on Outdoor Temperature. • Remote Indoor Sensor. • Large Display. • Back Lighting.
13_Thermostats_p190.indd 186-187
F.W. Webb Company
description Indoor Sensor Remote Outdoor Sensor
webb# 106402 167354
The 9600 Series are the perfect thermostats for affordable temperature control. This series was engineered to meet the most demanding heating and cooling needs.
9600
mfr# 9600 9610 9615 9620
Application ProgrammING 1 Heat / 1 Cool, Gas / Electric Systems 5-2 Day 3 Heat / 2 Cool, Gas / Electric Systems, Single Stage Heat Pumps 7-Day With Quickset 2 Heat / 2 Cool HTG Cool 7 Day 2 Heat / 2 Cool, Heat Pump Systems 7-Day With Quickset
webb# 92938 163776 318906 206850
Programmable Thermostats
webb# 308532
Universal Staging up to 3 Heat / 2 Cool The new 9725i2 makes installation even easier with our new Setup Wizard. The Setup Wizard allows you to spend 50% less time setting up the thermostat over competitive models. • Installation Wizard. • Adjustable Backlighting. • Cooling System Monitor. • Heating System Monitor. • Multi-language. • 5/2 Program. • 7 Day Programming. • Large Display.
186
webb# 112483 102665 112484 96971
9600
T8000 Provides 24 Vac control of heating and cooling systems with manual changeover from heat to cool. • Preprogrammed for your convenience. • Program up to four time periods and temperature setpoints. • Programs and setpoints are permanently held in memory in the event of power failure. • Large temperature display for quick easy readability.
9725i2 Deluxe Universal Programmable Thermostat
mfr# STAGING / Application 9725i2 1 Heat / 1 Cool / Gas, Electric Systems, Oil, Heat Pump
Application ProgrammING 1 Heat / 1 Cool 5-2 Day 1 Heat / 1 Cool 7 Day 3 Heat / 2 Cool or 2 Heat / 1 Cool Heat Pumps 7-Day 2 Heat / 2 Cool or 2 Heat / 1 Cool 7-Day
Accessories
9801i Deluxe Programmable Thermostat
mfr# STAGING / Application 9801i 1 Heat / 1 Cool / Gas, Electric Systems, Oil, Heat Pump
mfr# 300-224 300-225 300-227 300-229
13 thermostats
Robertshaw
T8000 Mfr# T8000C1010
Application Gas, Oil, Electric Heat-Cool
color Taupe
Power Method PowerStealing
SWITCH POSITION System
FAN
COOL-OFF-HEAT
AUTO ON
Webb# 91332
webb# 250686
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
187 3/24/08 11:44:35 AM
Programmable Thermostats
SECTION
13
13
Thermostat Guards
Programmable Thermostats
Versaguard Universal Thermostat Guards
T8112C Electronic Programmable Thermostat
TG510
Thermostat provides electronic programmable control for 24 Vac heating and cooling systems. • Separate schedules for weekdays and weekends (5-2 Programming). • Program up to four time and temperature settings per weekday schedule. • LCD continuously displays time and day, current program period and room temperature. • Temporarily override the current program with Warmer/Cooler keys. • Battery powered for increased compatibility. • Two AA alkaline batteries included. • Bat Lo is displayed when battery power is low.
Enclose and protect wall thermostats against tampering, damage and unauthorized adjustment of thermostat settings. • Unique double-wall construction provides extra measure of tamper-resistance. • Used in both new and existing applications. • Constructed of opaque polystyrene, clear acrylic, or beige painted steel. • Include opaque polystyrene wallplate, ring base, guard cover, tumbler lock, two keys and optional Honeywell logo insert. • Tamper-resistant lock; key cannot be removed without being in locked position. • All models mount vertically or horizontally on wall or exposed junction box. • Vents in guard base allow airflow for optimum thermostat performance.
TG510
SWITCH POSITION Mfr#
Application
color
System
FAN
T8112C1007
Gas, Oil, or Electric Heat Systems
Taupe
HEAT-OFF-COOL
ON-AUTO
Mfr#
Color
Ring Base Color
TG510A1001
Clear Acrylic
Clear Acrylic
Painted Metal
Opaque Ploystyrene
Webb# 153720
TG510D1005
Outside Depth
Height
Width
21/2”
77/8”
57/8”
27/17”
Outside
511/16”
13 thermostats
T8112C
SECTION
Inside Height
Width
47/16”
47/16”
Webb# 111382
511/16”
97186
TG511 Enclose and protect wall thermostats against tampering, damage and unauthorized adjustment of thermostat settings. • Unique double-wall construction provides extra measure of tamper-resistance. • Used in both new and existing applications. • Constructed of opaque polystyrene, clear acrylic, or beige painted steel. • Include opaque polystyrene wallplate, ring base, guard cover, tumbler lock, two keys and optional Honeywell logo insert. • Tamper-resistant lock; key cannot be removed without being in locked position. • All models mount vertically or horizontally on wall or exposed junction box. • Vents in guard base allow airflow for optimum thermostat performance.
Subbases Switching Subbase Q651 Provide manual system switching for T6051 and T6052 Thermostats. • Provide positive OFF switching of the system. mfr# Q651A1009
APPLication Switch labels Subbase for T6051A HEAT-OFF-COOL, HEAT-OFF-FAN, AUTO-OFF-FAN
webb# 104424
TG511 Mfr#
Color
Ring Base Color
TG511A1000
Clear Acrylic
Clear Acrylic
TG511B1008
Opaque Ploystyrene
TG511D1004 Painted Metal
Opaque Ploystyrene
Outside Depth
Outside Height Width
Inside Height
Width
Webb# 111384
215/16”
61/2”
71/2”
27/8”
63/8”
73/8”
51/16”
61/16”
95871 98142
Q651
188 13_Thermostats_p190.indd 188-189
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
189 3/24/08 11:44:35 AM
SECTION
13
Thermostat Guards
Versaguard Universal Thermostat Guards TG512 Enclose and protect wall thermostats against tampering, damage and unauthorized adjustment of thermostat settings. • Unique double-wall construction provides extra measure of tamper-resistance. • Used in both new and existing applications. • Constructed of opaque polystyrene, clear acrylic, or beige painted steel. • Include opaque polystyrene wallplate, ring base, guard cover, tumbler lock, two keys and optional Honeywell logo insert. • Tamper-resistant lock; key cannot be removed without being in locked position. • All models mount vertically or horizontally on wall or exposed junction box. • Vents in guard base allow airflow for optimum thermostat performance. • TG512A1058 Cover has a hole for access to up, down buttons on thermostat.
TG512
Ring Base Color
Mfr#
Color
TG512A1009
Clear Acrylic
Clear Acrylic
TG512B1007
Opaque
Opaque
TG512D1003
Painted
Opaque
Outside Depth
Outside Height
Width
Inside Height
Width
Webb#
111383 33/8”
71/4”
93/4”
57/8”
83/8”
69629 99107
Plastic Thermostat Guard WTG-EK mfr# description WTG-EK 37/8” X 31/2” X 21/2”
webb# 55791
WTG-EKTG587F1008
F.W. Webb stocks Buderus boilers!
190 13_Thermostats_p190.indd 190
F.W. Webb Company
www.fwwebb.com
3/24/08 11:44:36 AM
SECTION
14 mfr# X3B X4B X5B X6MC
Soldering Kits description webb# Air/Acetylene, Medium Duty 24699 Air/Acetylene, Heavy Duty 24700 Air/Acetylene, Lighter Duty 24701 Air/Acetylene, All Purpose 24702
Hoses AH12 12”, Acetylene H12 12”, LP Snappy Adapter SA To Quick Disconnect Tips Handle G4 For Acetylene H4 For LP “Total LP” Kit LP2 Medium/Heavy Duty LP3 Light/Medium Duty
LP Tips T2 5/16” T3 7/16” T4 1/2” T5 3/4” LP Regulator RLP For LP
24703 24704 24705 24706 24707 24708 24709 24710 24711 24712 24727 24715 24714 24726 24717 24718
24719 24720 24721 24722
24738
ST1
24750
The F.W. Webb Heating Catalog
14_Tools_p210.indd 191
mfr# description webb# Heat Shields HS5 For A-5, T-2, ST-1, ST-5 24730 Replacement Tank & Tank Accessories MT1 Mapp 16 oz. 24759 TK Tank Keys, B & MC Tanks 24768 MCT Tank Adapter 24784 TT150 B Tank Tote 57824 Brazing Rods BF1 Bronzeflow 24760 SF1 Copper/Phosphorus 24761 SS15 15% Silver, 5% Phosphorus 88326 Flint Striker L1 Flint Striker 24766 F1 Replacement Flints 24767 Regulators AG1 Acetylene Fuel Gauge 24786 ROF-LP LP Outlet Fitting 24797 245-03P Nitro Purge Regulator 192708
14
TL44 PL4T
PL8A
MT1
245-03P
24725
Hand Torch Kit STK9 Mapp & Propane Gas
Hand Torch Tip
Accessories
13
TOOLS
Acetylene Tips A2 3/16” A3 1/4” A5 5/16” A8 3/8” A11 7/16” A14 1/2” A32 3/4” Acetylene Regulators ARB Fits “B” Tank ARMC Fits “MC” Tank
mfr# description webb# Self Lighting Torch TX500 TurboLite® Mapp® & Propane 68105 Pro-Line™ Tip Complete PL3T 3/8” Mapp® & Propane 92006 ® PL4T 7/16” Mapp & Propane 92007 PL8A 5/16” Acetylene 92008 PL5A 3/16” Acetylene 92009 PL3A 1/4” Acetylene 201888
F.W. Webb is the exclusive distributor of purepro® trim kits for time-saving installations.
F.W. WEBB COMPANY
191 3/24/08 11:47:05 AM
Solder & Paste
SECTION
SECTION
14
14
Brushes
Soldering Paste
Flame Stop
Brushes
Nokorode Regular Paste Flux
Flare shield for soldering/brazing
Boiler Brushes
Will not freeze or decompose. No odor. Lead free. Recommended for use on all solder alloys including 95/5 and all lead free solders.
Protects wood, painted or metal surfaces from the heat and flame of a torch. Made from 2300°F material with a heavy flexible foil attached. It can be reused over and over again.
®
Nokorode® 95/5 Pre-Tinning Paste Flux Contains 95/5 solder. Great for large diameter fittings or faster soldering of small diameter fittings because it automatically tins before a high temperature is reached. Cuts waste. mfr# description webb# 14115 8 oz. Pre-Tinning 15084
Nokorode Cold Weather Paste Flux ®
Stays soft and sticky in cold weather. Recommended for use on all solder alloys including 95/5 and all lead free solders. mfr# description webb# 14730 1 lb. Cold Weather 73344
mfr# description webb# H2O Flux 10-303 4 oz. Water Soluable 118906 Solder paste w/Brush 10-608 2 oz. 78789 Meshcloth 45-013 11/2” X 10 yd. 56901 Sandcloth 45-030 11/2” X 25 yd. 30308
mfr# model # 9351 Model 1
84027 Weil-McLain Columbia Slant Fin
description Consists of (1) piece of 10” X 12”
webb# 71969
J. W. Harris mfr# 40021 40020 97030 40027 40002 40003 41035 40006 10009 10001 51035 75315 76310 75310 21035 66000 61035 60135 45535 10022
description Stay-Silver Brazing Flux, White, 8 oz. Stay-Silver Brazing Flux, White, 4 oz. Stay-Clean Silver Flux, 7 oz. Stay-Clean Flux, 4 oz. Stay-Clean Flux, 4 oz. Liquid Stay-Clean Flux, 16 oz. Stay-Clean Brazing Rod, 5% Stay-Clean Aluminum Flux, 4 oz., Brush Cap Stay-Brite 8, 1 lb. Stay-Brite 8, 1 lb. Stay-Silver 6, 1/8” x 20” Silver Solder, 5 oz. Roll Silver Solder, 45% 1 Troy oz. Silver Solder, 10 oz. Roll Harris O Brazing Rod Brazing Rod, Dynaflow Brazing Rod, 15% Stay Clean Brazing Rod, 15%, 1/8” Square Brazing Rod Aluminum Solder Kit
webb# 152425 152424 97249 97317 97008 97019 97303 112498 100243 100141 205275 225227 96810 225226 99480 106647 107676 252234 255098 100435
mfr# 84006 84200 84201 84027 84009
description 1/2” X 1” X 27”, Columbia, Flat 11/2” X 11/2” X 30”, Weil-McLain 11/2” X 17/8”, Weil-McLain Horsehair 17/8” X 11/8”, 42” Horsehair 21/8”, 20” Tapered Slant Fin
Silverbrite Solder mfr# 100 30060 57307 75014
mfr# 5050 955 5050BAR
Radiator Brushes mfr# description Copper Fitting Brush w/ Handle 01405 21/2” X 42”, Carbon Steel, 4” Loop 39961 2” X 27”, Horsehair Tube Brush 39962 3” X 27”, Fiber/Horsehair Tube Brush 04964 1/2” X 12” Horsehair Tube Brush 01490 3” X 42”, Tampico Tube Brush 01270 1” X 36” Stainless Steel
mfr# 96010 96020 96031 96051 96071 96100
69592 69593 69594 69606 69595 69596
webb# 68271 255625
Soot Shovel mfr# Desc. S412 Soot Shovel
webb# 253350
description webb# 34409 3/8” X 1/2” 15086 1/2” X 5/8” 15087 3/4” X 7/8” 15088 1” X 11/8” 15089 2” X 21/8” 68640 1/8” X 1/4”
mfr# 61212 61332 61453 61502 61562 61622
description webb# Lead Free Solder 44041 Silvaloy 6 191058 Silvaloy A-56T 191059 Ultra Flux II, 7 oz. 191060
description webb# 15090 3/4” 15091 1” 45093 11/4” 45094 11/2” 45095 2” 68638 1/2”
#6700 Heavy-Duty Copper Fitting Brush
description webb# 1 lb., 50/50 40085 1 lb., 95/5 13375 1 lb., 50/50 Stick 13377
mfr# description webb# 67045 11/4” X 13/8” 244151
mfr# description webb# 70606 14” X 1” 69597 70650 10” Duster 69598
14_Tools_p210.indd 192-193
webb#
mfr# Desc. S405W Soot Saw S402W Heavy Duty
14
#9600 Standard Copper Fitting Brush
Scratch Brushes
F.W. WEBB COMPANY
webb# 58353 68144 68145 68146 81480
13
#6100 Hard-Head Copper Fitting Brush
Solder Spool
192
Specially designed for easier clearing of soot build-up in most narrow passage boilers. Flexible design, effectively breaks up hardened carbon deposits in between sectional studs in narrow passage boilers. Made of tempered steel.
TOOLS
mfr# description webb# 14000 1.7 oz. Solder Paste 15082 14030 1 lb. Solder Paste 15083
Soot Saw
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb has over 70 locations throughout New England and New York! F.W. WEBB COMPANY
193 3/24/08 11:47:07 AM
Vacuum Cleaners
SECTION
SECTION
14
14
Mastercraft
Gloves
Sootmaster
Mfr# size Leather Gloves 238L LG Suede 268L LG Thermal Lined
mfr# 641M 652M
capacity Style includes shipping wGt .50 bushel/17.62 liters Steel, 3 Caster Canvas Hose w/Swivel 35 lbs./15.9 kilos .75 bushel/26.43 liters Steel, 4 Caster 27” Crevice Tool 38 lbs./17.2 kilos
webb# 13113 13114
Accessories & Replacement Parts webb# 13111 13112
Swivel Hose Connector 1455R For 11/2” ID Vacuum Crevice Tool 103-2 27” metal Dacron Filter Bag — Prevents particles from clogging filter assembly CV46A Use with 14” dia. filters
69618
69619 79064
Cloth Filter 1126 14” filter gasket
69617
Filter Frame 1017 14”
249188
Motor Replacement 5041R
250495
14_Tools_p210.indd 194-195
F.W. WEBB COMPANY
LG Unlined, Elastic Back
45373
7015
LG Welders (Red)
45381
4104
LG Imported Leather Palm
45376
6563L
LG Leather Palm w/Cuff
45377
3927L
Leather Palm w/Thinsulate
152951
Cotton Gloves 908 8 oz. Flannel Knit
42362
808
8 oz. Brown Jersey
45384
C110
Sring Knit
45389
322L
• Proprietary motor and patented blower wheel design maximize performance. • Pleated paper filter has more surface area for greater efficiency with longer intervals between changes. • Automatic suction shutoff senses and prevents liquid overflow; integral drain plug makes draining the vacuum easy. • All units convert to a powerful blower with at least 150 mph blowing capacity. • Rugged polypropylene drum is impact and corrosion resistant. • Smooth drum interior for easy emptying of debris. • Power profile for less risk of tip over. • Lower drainage spout, designed to empty all liquid content easily. • Reduced dB level resulting in quieter operation. webb# 252706 202765
Blue, MyGuard Nitrile Gloves provides protection against oils and greases with its petro chemical resistant coating. • Lightly powdered for ease of use. • Puncture resistant, cost effective, disposable. • Textured fingertips for greater grip control. • 5 mils thick in fingers, 4 mils in palm and cuff.
168L
Latex Gloves 3642XL XL Flock Lined
Ridgid Wet/Dry Vac
description 6 Gallon 14 Gallon
MyGuard Nitrile Gloves Petro-Chemical Resistant Nitrile Gloves
69615
Hose Cage 1700 For 14” dia. canisters
mfr# 96877 18718
45362 45368
69614
Flexible Metal Hoses 103-7 11/2” X 6’, Heat resistant packing 118663 103-10 1” X 6’, Heat resistant packing 69616 S410W Soot Snake 7/8” X 48” Fits std 11/2” Vac Hose 71823
mfr# description 72947 VF4000 Replacement Filter 72952 VF5000 Hi Efficiency Replacement Filter
LG Disposable Exam. Latex
Rubber Gloves PVCRUBBER Disposable Rubber Disposible Vinyl Gloves 432M MED Vinyl (100 Pack) 432L LG Vinyl (100 Pack) PVC Gloves 7305 LG Orange PVC Oil Drivers 937M 938L 937XL 3-173 3-193
MED Green 6.5 Mil. LG Green 6.5 Mil. XL Green 6.5 Mil. Monkey Grip (LP) Winter Monkey (LP)
13
webb#
14 TOOLS
mfr# description Disposable Paper Filter Bags 4464 For 641M 4465 For 652M Rubber Lined Canvas Hose – White 7HB-7 11/2” X 10’, Expanded Ends
194
Safety Tools
Mfr# size webb# MG-1103 Large 243251 MG-1104 X-Large 243252
Raingear Yellow 3-Piece Rainsuits PVC Boots Mfr# size webb# 810YL Large 45399 810YXL X-Large 45400
Mfr# size 865-10 10 865-11 11 865-12 12
webb# 45410 45411 45412
42346 202515
95443 216359 246639 244281 87359 87360 222559 181493 181496
Ladders Mfr# size webb# Platform Step Ladder 3514 4’ 47122 Fiberglass Extension Ladder 31024 24’ 47129 Fiberglass Step Ladder 6204 4’ 58281 6206 6’ 58282 6208 8’ 58283
webb# 216662 240988
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. WEBB COMPANY
195 3/24/08 11:47:11 AM
Safety Tools Hats, Goggles, Respirators, Masks, Plugs
Hy Excel Clear Frames 18780 Onyx Lens
webb# 88272 88273 88298 88295
14
14
88288 88290 88291
Moldex Masks 28076 Dust RS900N95 Dust & Mist C3010947 Dust & Mist
88292 88293 88294
Flashlights & Batteries
First Aid Kits • Contains 168 pieces of First Aid treatments. • Neat interior packaging of the contents keeps the kit organized and makes it easy to locate and use the first aid treatments when you need them. • Contents meet requirements of American National Standards Institute Standard Z308.1-1998 for First Aid Equipment in an industrial work environment. • Rugged wall mounting weatherproof plastic case constructed to keep the contents free of dust and moisture.
mfr# IN2 IN3 IN4 IN2KML
description Industrial 2-Cell Flashlight Industrial 3-Cell Flashlight Mini Flashlight Industrial 2-Cell With Magnet
Roughneck Adjustable Focus ISL2D-B ILJ2AA-B
webb# 58520 58521 58522 45301
Mini
Mfr# size 6430 25 Person First Aid Kit FAK6084 First Aid Kit
webb# 72371 244557
88300
V2D-B
BR2D-B BR2AA-B
93584 206620
193974 193973
Swivel-Light Mini
Value Brights
Black Industrial With 2 D Batteries Black Industrial With 2 AA Batteries
206621
206617 206618
Rags Mfr# size 5LBRAGS 5 lb. Bag Terry Rags BAGORAGS 1 lb. Bag Terry Rags OILMANRAG 1 lb. Bag Cloth Rags (Blue) 570900B402LBPB 21/2 lb. Pkg. Handiwipes
webb# 189810 77853 91124 166177
mfr# description Batteries — 4 Packs 6VHD 6V Square 814-4 C-Cell 813-4 D-Cell 815-4 AA 824-4 AAA NM715-4 AA Rechargeable NM724-4 AAA Rechargeable
14_Tools_p210.indd 196-197
48-11-300
12 Volt
130335
48-11-1024
14.4V, 2.4 Amp
192192
48-11-2230
18 Volt
205873
Work Lights 49-24-0155
Rechargeable
151289
49-24-0165
18 Volt
205874
Work Light Bulbs 49-81-0030 2 Pack 49-81-0020 14.4 Volt Krypton Light Bulb 49-81-0010 Universal Chargers 48-59-0255 A/C 48-59-0186
D/C
48-59-0192
Super Charger II 120 Volt
209690 224559 155221 223133 240501 53097
www.fwwebb.com
webb# 93585 40859 40860 40861 40875 243641 243641
GRANBY
F.W. WEBB COMPANY
mfr# Description Webb# Battery Packs 48-11-0080 9.6 Volt 34590
Batteries
F.W. Webb stocks granby oil tanks!
196
14
Worklights, Batteries, Chargers
Roughneck Mini
Swivel-Lite With 2 D Batteries Mini Swivel Light
Swivel-Light Foam
13
Flashlights
Industrial C-Cell R2D Roughneck Adjustable Focus R2AA-BA Mini Roughneck
88285
Paint Spray Respirator 94795 With Cartridge 94797 With Cartridge Organic With Cartridge 94798
Ear Plugs 25329
SECTION
TOOLS
mfr# description Sentry III Hard Hat HP16110 White HP16160 Blue Clear Visor 22644 For Sentry III Goggles 10013 Soft Sided
SECTION
The F.W. Webb Heating Catalog
F.W. Webb stocks Bradford white water heaters! F.W. WEBB COMPANY
197 3/24/08 11:47:14 AM
Hand Tools
SECTION
SECTION
14
14
Hand Tools
13 MFR# DESCRIPTION WEBB# CRT34-73576 12/2 14/2 Wire Strippers 303385
303413 303399
CRT67-789 CRT67-791
10” Waterpump Pliers 123/4” Waterpump Pliers
306413 306414
CRT9-10153
3/8” 14.4V Cordless Drill
303430
CRT9-1295 CRT9-1313 CRT9-16952
7 PC Standard Nut Driver Set 7 PC Metric Nut Driver Set Pump Out Wet/Dry Vac
361501 361502 361509
CRT9-17713
CRT9-17741
2 Gallon Wet/Dry Vac
6 Gallon Wet/Dry Vac
303556
MFR# DESCRIPTION WEBB# CRT9-44602 6” Adjustible Wrench 305297 CRT9-44603 8” Adjustible Wrench 305298 CRT9-44604 10” Adjustible Wrench 305299 CRT9-44605 12” Adjustible Wrench 305300 CRT9-44606 18” Adjustible Wrench 305301
CRT9-26678
Wet/Dry Vac Filter
MFR# DESCRIPTION WEBB# CRT9-42160 5 PC Box End Ratchet Wrench Set 304441
CRT9-42191 304455 CRT9-42195 304459
Circular Saw Wax Strips
303852
CRT9-44664 3 PC Adjustible Wrench Set 305306 CRT9-45076
CRT9-42380 304492 CRT9-42409 304509
305366
7” Diagonal Cut Wide Jaw Pliers
3/8” Cushion Grip Nutdriver
CRT9-45094 81/2” Lineman Pliers 305372
5 PC Combination Ratchet Wrench Set 5 PC Metric Ratchet Wrench Set
305374
8” Long Nose Pliers
CRT9-45285
3/8” Power Electric Drill
CRT9-45381 CRT9-45384 CRT9-45385 CRT9-45386
303903
CRT9-28640
Multi-Angle Reciprocal Saw
303929
CRT9-33122 CRT9-34802 CRT9-34824
122 PC Mechanic’s Tool Set 20 PC 3/8” Socket Set 79 PC 1/2” Socket Set
303999 304105 304119
305437
CRT9-45715
10” Locking Pliers
305439
CRT9-45761
91/2” Arc Joint Pliers
305459
CRT9-45763
8” Long Nose Pliers
305461
CRT9-43375
CRT9-46701 Folding 9 Key Hex Wrench 305596 CRT9-47044
9 PC Combination Wrench Set
CRT9-41063 CRT9-47108
5/16” X 6” Cushion Grip
CRT9-47112 CRT9-47115 CRT9-47116 CRT9-47117
#3 X 6” Cushion Grip Cushion Grip 5/16” X 6” Cushion Grip Cushion Grip 6 PC Cushion Grip Cushion Grip Set #2 X 6” Cushion Grip Phillips Screwdriver
Screwdriver 1/4” X 6” Cushion Grip Phillips Cushion Grip
305681
361515 361514
305379
3 PC Plier Set
CRT9-27996
3 PC Locking Pliers Set
3/16” Cushion Grip Nutdriver
303593
303566
CRT9-45713
14
18”
CRT9-45103 CRT9-17816
MFR# DESCRIPTION WEBB# CRT9-45711 7” Locking Pliers 305435
TOOLS
CRT34-73893 Fluorescent Work Light CRT34-82139 Multi Meter
MFR# DESCRIPTION WEBB# CRT9-37391 25’ Tape Measure 304244 CRT9-37393 30’ Tape Measure 304246 CRT9-37396 12’ Tape Measure 304250 CRT9-41972 5/16” Nutdriver 304422 CRT9-41973 11/32” Nutdriver 304423 CRT9-41974 3/8” Nutdriver 304424 CRT9-41976 1/2” Nutdriver 304426
305395 305396 305397 305398
91/2” Arc Joint Pliers 16” Arc Joint Pliers 7” Arc Joint Pliers 13” Arc Joint Pliers
5 Piece Offset Ratchet Wrench Set
305690 305693 305694 361513
13”
CRT9-37342
198 14_Tools_p210.indd 198-199
15” Prybar
304171
F.W. WEBB COMPANY
CRT9-45570 CRT9-45571
www.fwwebb.com
2 PC Strap Wrench Set Aluminum Strap Wrench
The F.W. Webb Heating Catalog
305413 361500
#2 X 6”
CRT9-47136
8 PC Screwdriver Set
305696
F.W. WEBB COMPANY
199 3/24/08 11:47:17 AM
Hand Tools
SECTION
SECTION
14
14
Hand Tools
6 in 1 Screwdriver mfr# Description Webb# MIS6-1 6 In 1 Screwdriver 44642 MFR# DESCRIPTION WEBB# CRT9-41161 4 In 1 Screwdriver 304329
CRT9-59236 CRT9-59423
10 In 1 Screwdriver Tote Tool Bag
Double Cover Steel Cantilever Tool Box 23” Plastic Tool Box
361512 304271
These models are best suited for trim cutting soft sheet metal and for cutting a multiple of other materials. The P6716-S straight cut avaiation snip is the most versatile of all aviation snip models. mfr# Description Webb# P6716-S Straight Cut, Yellow 44604 Cuts straight and wide curves to the left and right
305899 306016 P6716-L Left Cut, Red Cuts straight and wide curves to the left
CRT9-65247 CRT9-65431 CRT9-66858 CRT9-94853 CRT9-94856
6 Drawer Tool Chest 17” Plastic Tool Box 15 PC Cobalt Drill Set Aluminum Utility Knife High Visibility Utility Knife
305985 306014 306085 306129 361504
CRT9-94857 CRT9-94859
5 Pack Utility Knife Blades 100 Pack Utility Knife Blades
306132 306134
44603
Aluminum Handle Offset Pipe Wrench Nearly 50% lighter than comparable cast-iron models of the same size. Features a jaw opening parallel to the handle and a narrower hook jaw head which provides easy entry into tight spots. 31120 14” — 2” Pipe Capacity 16906 31125 18” — 21/2” Pipe Capacity 16907 31130 24” — 3” Pipe Capacity 16908
P6716-R Right Cut, Green 44605 Cuts straight and wide curves to the right
These models are best suited for making long cuts through soft sheet metal and a multitude of other materials. The offset blade pattern guides the material being cut away from the blades. The offset blade pattern also positions the user’s hand above the material being cut. mfr# Description Webb# P6510-L Offset Left Cut, Red 80234 Cuts straight and tight left curves P6510-R Offset Right Cut, Green Cuts straight and tight right curves
80233
P6716-B is best suited for cutting multiple thicknesses and rolled edges of sheet metal and up to 16 gauge soft sheet metal as well as other thick materials. mfr# Description Webb# P6716-B Right Bulldog/Notch Cut 80236 Short straight cuts
200 14_Tools_p210.indd 200-201
F.W. WEBB COMPANY
www.fwwebb.com
Aluminum End Wrench Ideal for jobs in close quarters, such as where the pipe to be turned is close to a wall, or where several pipes are running close together. The aluminum handle makes the wrench 40% lighter than other malleable iron wrenches, thus making one-handed operation virtually no work at all. 90107 10” — 11/2” Pipe Capacity 247222 90117 14” — 2” Pipe Capacity 247223 90122 18” — 21/2” Pipe Capacity 247224 90127 24” — 3” Pipe Capacity 247225 Hex Wrench Hex jaw design gives multi-sided, secure grip on all hex nuts, square nuts, unions, and valve packing nuts. 31305 E-110 91/2” — 11/8” – 25/8 Pipe Capacity 16927 Cutter Wheels 33100 F-514 f/Steel & Ductile Iron 17202 33105 F-3 f/Steel & Ductile Iron 17197 33110 F-3S f/Steel & Ductile Iron 17198 33120 F-515 f/Steel & Ductile Iron 55087 33125 F-229 f/Steel & Ductile Iron 17200 33145 F-367 f/Steel & Ductile Iron 55085 44185 E-1032 f/Steel & Ductile Iron 17195 Portable Tristand Vises Integral legs and tray fold in for easy carrying and setup. Large vise base overhangs front legs for clear tool swing. Complete with slots for hanging tools, pipe rest, three pipe benders, and ceiling brace screw. 40130 Tristand Yoke Vise, 1/8” - 21/2 17007 72037 Tristand Chain Vise, 1/8” - 6 17008
The F.W. Webb Heating Catalog
mfr# Description Webb# Pipe Taps, Hand Use Only Made from carbon steel in right hand configuration only. These taps are especially suited for restricted area work. All taps have taper of 3/4” per foot. 35815 1/8” Pipe Size 16944 35820 1/4” Pipe Size 16945 35825 3/8” Pipe Size 16946 35830 1/2” Pipe Size 16947 35835 3/4” Pipe Size 16948 35840 1” Pipe Size 16949 35845 11/4” Pipe Size 16950 35850 11/2” Pipe Size 16951 35855 2” Pipe Size 16952 DRILL PIPE THREADS Mfr# Model# SIZE SIZE PER Inch Webb# 35815 E-5112 21/64 1/8” 27 16944 35820 E-5113 7/16 1/4” 18 16945 35825 E-5114 9/16 3/8” 18 16946 35830 E-5115 45/64 1/2” 14 16947 35835 E-5116 29/32 3/4” 14 16948 35840 E-5117 19/64 1” 111/2 16949 35945 E-5118 131/64 11/4” 111/2 16950 35850 E-5119 147/64 11/2” 111/2 16951 35855 E-5120 215/64 2” 111/2 16952 Manual Pipe Threaders (Ratchet & Handle Only) Ratchet knob indicates forward and reverse. Die heads snap in from both sides and lock in place.
13 14 TOOLS
CRT9-47480 CRT9-48343
mfr# Description Webb# Straight Pipe Wrench Sturdy, cast-iron housing and I-beam handle with full floating forged hook jaw, adjustment nut and replaceable hook and heel jaws. 31000 6” — 3/4” Pipe Capacity 16887 31005 8” — 1” Pipe Capacity 16888 31010 10” — 11/2” Pipe Capacity 16889 31015 12” — 2” Pipe Capacity 16890 31020 14” — 2” Pipe Capacity 16891 31025 18” — 21/2” Pipe Capacity 16892 31030 24” — 3” Pipe Capacity 16893 31035 36” — 5” Pipe Capacity 16894 Aluminum Pipe Wrench Nearly 40% lighter than comaprable cast-iron models of the same size. Jaws and all other parts identical to Ridgid Heavy-Duty Wrenches. 31090 10” — 11/2” Pipe Capacity 16909 47057 12” — 2” Pipe Capacity 95189 31095 14” — 2” Pipe Capacity 16910 31100 18” — 21/2” Pipe Capacity 16911 31105 24” — 3” Pipe Capacity 16912 31110 36” — 5” Pipe Capacity 16913 31115 48” — 6” Pipe Capacity 16914
mfr# Description Webb# 38540 Model # OO-R 16992 38555 Model # 12-R 16995 Tube Cutters Nos. 10,15,20 & 30 Clean, square cuts are easily made on copper, brass, aluminum, and thin-wall conduit.Feature a convenient fold away reamer. No. 30 is rated for larger diameter steel and stainless steel tubing. 32915 1/8” — 1” 17069 32925 3/16” — 11/8” 17070 32930 5/8” — 21/8” 151471 32935 5/8” — 21/8” 17071 32950 1” — 31/8” 17072 Mod StD. Mfr# # Decription Wheel Webb# 32915 10 Screw Feed Tube Cutter w/H-D Wheel E-1240 17069 32925 15 Screw Feed Tube Cutter w/H-D Wheel E-1240 17070 32930 20 Screw Feed Tube Cutter F-158 151471 32935 20 Screw Feed Tube Cutter w/H-D Wheel E-1240 17071 32950 30 Screw Feed Tube Cutter w/H-D Wheel E-2191 17072 Midget Tubing Cutters Designed for use in restricted spaces on small diameter, hard and soft copper, aluminum, brass, and plastic tubing. Strong, lightweight slide and wheel housing, large knurled feed screws knob gives easy control of cutting pressure for clean cuts. The Model 118 has a self-feeding cutter wheel that automatically cuts after tightening the knob only once. StD. Mfr# Mod# Decription Wheel Webb# 32975 103 Midget Cutter E-3469 17053 32985 104 Midget Cutter E-3469 17054 86127 118 Self Feeding Midget Cutter E-3469 57823
F.W. WEBB COMPANY
201 3/24/08 11:47:19 AM
Hand Tools
Tubing Cutters Features an enclosed feed screw to eliminate clogging and jamming, grooved rolls for close-to-flare cuts, and a fold-away reamer. Made from high-strength zinc alloy with a spare cutter wheel in the handle. Cuts copper, brass, and aluminum tubing, and thin-wall conduit. Model 205 has all the features of the No. 150, plus a quick-acting mechanism. description WEBB# 1/8” – 11/8” 17065 1/4” – 23/8” 17066
mfr# MODEL 31622 150 33055 205
description STD. WHEEL Enclosed Feed Cutter E-3469 Ratcheting Encl. Feed Cutter E-3469
Quick Acting Tubing Cutters Models 151-156 feature a quick-acting design, I-beam construction, hardened wear surfaces, and thrust bearing slide assemblies for smooth operation. Mfr# Mod# Description 31632 151 1/4” – 15/8” 31642 152 1/4” – 25/8” 31652 154 17/8” – 41/2”
Std. Wheel Webb# E-3469 52695 E-3469 52696 E-2558 52697
No 345 Flaring Tool Model 345 is a precision designed tool for producing 45° flares in soft copper, brass, aluminum, and mild steel (JIC and Bundy) tubing. A hardened, smooth cone provides fast, 45° flares either single or double lap. A single clamp screw provides for easy clamping and removal of tubing. mfr# MODEL TYPE Sizes WEBB# 23332 345 45° S.A.E. Flare 3/16”, 1/4”, 5/16”, 54831 3/8”, 7/16”, 1/2”, 5/8” No. 458R Ratchet Flaring Tool This precision tool provides smooth, uniform flares with minimum effort. The new ratcheting feed screw handle turns easily and requires less motion and effort than a standard handle. Hadened steel flaring cone, accentrically mountei needle bearings, produces rolling action for even metal flow, giving uniform flare walls without galling. mfr# MODEL TYPE Sizes WEBB# 83037 458R 45° S.A.E. Flare 1/8” 3/16”, 1/4”, 5/16”, 17087 3/8”, 1/2”, 5/8”, 3/4”
F.W. Webb is the exclusive distributor of the Energy Star
SECTION
14
14
Mfr# Model# Application Webb# Cutter Wheels 33210 E-702 Heavy Wall PVC, ABS 17180 33165 E-1240 Steel, SS 17181 33175 E-2191 Steel Tubing 17183 33170 E-2558 Aluminum & Copper 17184 33205 E-2990 Steel, Aluminum, Copper 17186 33185 E-3469 Aluminum & Copper 17187 34695 E-3495 Aluminum 17188 33190 E-4546 Steel, SS 17189 33195 E-4546 Steel, SS 17190 33160 F-158 Aluminum & Copper 17192 Wheel Parts 34105 E-1439X Wheel Pin Assembly 54462 34180 E-1452X Wheel Pin Assembly 54463 34345 5 Pack Wheel Screws 54465
Hand Tools
13 Hand Saws
Crimper • Four tools in one: - Bolt Cutter. - Crimper. - Wire Cutter. - Wire Stripper. Newly designed, lightweight, and economical. This convenient sized, multi-purpose tool is made for durability. Handles are plastic coated. mfr# DescRIPTION 40400 Crimper
webb# 249595
400 Series Lever Benders 400 Series Instrument Benders combine accuracy with easy operation. Offset accuracy with easy operation. Offset cushion grip handles eliminate knuckle cracking when forming 180° bends.
TUBE SIZE BEND Mfr# Model# Descr. (OD) Radius Webb# 36097 406 3/8” 15/16” 17084 36132 408 1/2” 1 1/2” 17085 The 456 Tri-Bender is designed to easily bend three different sizes of soft tubing: 1/4”, 5/16” and 3/8” with the same tool. A 90° start angle minimizes effort required to form a bend. mfr# description WEBB# 44852 1/4”, 5/16” & 3/8” Tri-Bender 70311 The 395 Torpedo Level Ideal for general use and work in tight places. Three vials for plumb, level and 45° miter. Full length strong magnetic edge. V-grooved edge for pipe and conduit work. Large top read level vial. mfr# description WEBB# 20233 9” Long Torpedo Level 17179 mfr# Description Webb# Pipe Cutters 32810 Heavy Duty 1A 17019 32820 Heavy Duty 2A 17020 32830 Heavy Duty 3S 17021 32840 Heavy Duty 4S 17022 32845 Heavy Duty 3 Wheel 4S 19401 32850 4-6” Heavy Duty 6S 150000
Hacksaw Frame
Tri-Fold Saw
Mfr# DESCR webb# 4012 44289 2012 With Blade 73794
Mfr# 61836
webb# 58159
14 TOOLS
mfr# 31622 33055
SECTION
Close Quarter Saw Mfr# 906
975 Hacksaw Mfr# 975
webb# 81402
webb# 44297
Swedging Tool mfr# Description webb# Swedging Tool 4330 3/8” X 3/4” 75282 Radiator Spud Wrench 4558 75293 Mill Bastard File 5505 8” 75676 Spring Tube Bender 5162 3/8” 75691 5164 1/2” 75692 4-in-1 Fitting Brush 5150 Complete 79997 5150R Brush Replacement 152822 Hex Key Set 3040 9 Keys, 2” – 37/8” 162669 Radiator Valve Wrench 4947 3-Way
87130
Shurlite Spark Lighter 4437 162670 4438 Replacement Flints 180300 Radiator Vent Valve L/Key 605LK 208676
mfr# Description webb# Long Nose Plier w/Side Cutter 317 71/2” Diagonal Cut Plier
110875
337 7” 110876 Linesman Plier w/Rounded Nose 348 81/2” Tongue & Groove Plier 426 61/2” 430 10” 440 12” 460 16” Wiring Tool
110874 205871 93008 93009 110873
908 Griplock Tongue & Groove Plier GL10 10” GL12 12” Nutdriver Set
95039
EZ7S
57708
7 Piece
58729 58730
rated trio cast iron boiler!
202 14_Tools_p210.indd 202-203
F.W. WEBB COMPANY
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. WEBB COMPANY
203 3/24/08 11:47:21 AM
Power Tools
SECTION
SECTION
14
14
Power Tools
Corded Tools
Electric Tools Cordless Tools
18V Cordless Sawzall 0819-21 With 2 Batteries, Charger, Two Blade Pack & Steel Carrying Case 154834 “The Hatchet” Cordless Sawzall 6514-21 18 Volt
246651
Right Angle Drill 3102-6
Reversible Drill 0234-6 1/2” — 0-850 RPM
Abrasive Cut-Off Saw 6175-20 14”
(cont.)
Accessories mfr# Description Webb# Job Site Radio 49-24-0280 World’s Toughest Radio 252136
13365
129368
Carrying Case 48-55-0711 General Purpose
49273
Reversible Drive 48-06-2871 Right Angle
13237
13
Model 300 Compact Threading Machine Features: • Heavy-duty proven performance. • Lightweight, portable design. • Fast transport and set-up. • Self-contained oil system. • Versatility for threading & grooving. • CSA approved. • Approved to UL Standards. Standard Equipment: Model 300 Compact Threading Machine 1 – No. 811A quick-opening die head 1 – No. 344 Reamer 1 – No. 360 Cutter with E-1032 Cutter Wheel 1 Set 1/2” – 3/4” Alloy Universal Dies 1 Set 1” – 2” Alloy Universal Dies 1 Gallon Nu-Clear Threading Cutting Oil
14 TOOLS
mfr# Description Webb# Combination Kit 0926-24 18V Sawzall, Hammer Drill, Circular Saw, Worklight & Contractor Bag 243054
Electric Tools
mfr# Description Webb# Reversable Drill 1676-6 2 Speed, 1/2” w/Case 13364
mfr# Description Webb# 15682 Compact Threading Machine 49368
129835
Thread Cutting Oils
Cordless Drill 0615-24
Heavy Duty 14.4 Volt With Worklight 129339
Cordless Drill 0627-24
18 Volt Kit
Circular Saw 0840-22
Metal Cut Saw w/ Bag 251343
Sawzall, Light, Driver Drill Combo 0901-24 With Case
Impact Wrench 0879-22 1/2” Square 18 Volt Drive
251342
205872
Deep Cut Portable Band Saw 6238 43/4”
• Cools threads and pipe during operation. • Speeds metal removal. Ridgid thread cutting oils are free of chlorine and other halogens, PCBs and heavy metals. Complete material safety data sheet available. Dark Oil – Traditional mineral oil with low odor and antimist formulation. Nu-Clear Oil – Clear mineral oil with low odor and antimist formulation. Special low temperature properties maintain workable viscosity to -20F. Stainless Steel Oil – High performance mineral oil formulated to produce superior quality threads on stainless steel and black pipe. Water Washable – Synthetic thread cutting fluid cleans easily off concrete, clothing, and piping with water. Biodegradable.
204437
Sawzall 6509-22 With Case & Blades 166577 Metal Cutting Shears 6852-20 18 Gauge
Rotary Hammer 5321-21 11/2”
Super Hawg 1680.21
Roto-Lok
130004
42266
252137
F.W. Webb with Webbconnect
251344
mfr# Description Webb# 70835 1 gal. Nu-Clear 17035 41575 5 gal. Nu-Clear 178052 70830 1 gal. Dark 199558 74007 1 qt. Stainless Steel 214680 74017 1 qt. Water Washable 214682 74022 1 gal. Water Washable 223739
allows you to figure jobs, get pricing, order material,
Caulking Gun 6560-21
204 14_Tools_p210.indd 204-205
12 Volt
24 hours a day/7 days a week!
251345
F.W. WEBB COMPANY
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. WEBB COMPANY
205 3/24/08 11:47:25 AM
SECTION
SECTION
14
14
Power Tools ProPress Tools & Jaws
ProPress Fittings
The heart of the ProPress System is the electro-hydraulic crimping tool fitted with interchangeable crimping jaws and rings. The rugged unit is designed for continuous crimping on all kinds of jobs — big and small. webb# 216815 216386
ProPress Jaw Sets
ProPress Crimp Rings
mfr# size 76677 2” Jaw Assembly
webb# 216814
ProPress Fittings
mfr# size 93667 3-Ring Kit With 21/2”, 3”, 4” Crimp Rings, Ring Actuator and Carrying Case
Adapter C X M
Adapter C X F
Cap C
mfr# size webb# Bronze Adapter C X M 77812 1/2” X 3/8” NPT 216894 77817 1/2” X 1/2” NPT 216895 77822 1/2” X 3/4” NPT 216896 77827 3/4” X 1/2” NPT 216897 77832 3/4” X 3/4” NPT 216898 77837 1” X 3/4” NPT 216899 77842 1” X 1” NPT 216407 77847 1” X 11/4” NPT 216900 77852 11/4” X 1 NPT 216901 77857 11/4” X 11/4” NPT 216408 77862 11/4” X 11/2” NPT 216902 77867 11/2” X 11/4” NPT 216903 77872 11/2” X 11/2” NPT 216409 77877 2” X 2” NPT 216904
mfr# size webb# Bronze Adapter C X F 77887 1/2” X 3/8” NPT 216905 77892 1/2” X 1/2” NPT 216906 77897 1/2” X 3/4” NPT 216907 77902 3/4” X 1/2” NPT 216908 77907 3/4” X 3/4” NPT 216909 77912 1” X 3/4” NPT 216910 77917 1” X 1” NPT 216911 77922 1” X 11/4” NPT 216912 77927 11/4” X 1” NPT 216913 77932 11/4” X 11/4” NPT 216914 77937 11/4” X 11/2” NPT 216915 77942 11/2” X 11/4” NPT 216916 77947 11/2” X 11/2” NPT 216917 77952 2” X 2” NPT 216918
mfr# size Copper Cap C 77712 1/2” 77717 3/4” 77722 1” 77727 11/4” 77732 11/2” 77737 2” XL Bronze Cap C 91432 21/2” 91437 3” 91442 4”
XL Bronze Adapter C X M 91332 21/2” X 21/2” NPT 244804 91337 3” X 3” NPT 244805 91327 4” X 4” NPT 244806
Adapter FTG X F mfr# size webb# Bronze Adapter FTG X F 78002 1/2” X 3/8” NPT 216928 78007 1/2” X 1/2” NPT 216929 78012 1/2” X 3/4” NPT 216930 78017 3/4” X 1/2” NPT 216931 78022 3/4” X 3/4” NPT 216932 78027 1” X 1” NPT 216933 78032 11/4” X 11/4” NPT 216934 78037 11/2” X 11/2” NPT 216935 78042 2” X 2” NPT 216936
206 14_Tools_p210.indd 206-207
90° Elbow C X C Close Rough
Adapter FTG X M mfr# size webb# Bronze Adapter FTG X M 77957 1/2” X 3/8” NPT 216919 77962 1/2” X 1/2” NPT 216920 77967 1/2” X 3/4” NPT 216921 77972 3/4” X 1/2” NPT 216922 77977 3/4” X 3/4” NPT 216923 77982 1” X 1” NPT 216924 77987 11/4” X 11/4” NPT 216925 77992 11/2” X 11/2” NPT 216926
F.W. WEBB COMPANY
webb# 216874 216875 216876 216877 216878 216879 244810 244811 244812
webb# 244852
Coupling C x C with Stop mfr# size webb# Copper Coupling C X C With Stop 78047 1/2” 216937 78052 3/4” 216938 78057 1” 216410 78062 11/4” 216411 78067 11/2” 216412 78072 2” 216939 XL Bronze Coupling C X C With Stop 91342 21/2” 244816 91347 3” 244817 91352 4” 244818
Cross-Over C X C mfr# size webb# Copper Cross-Over C X C 77742 1/2” 216880 77747 3/4” 216881
Cross-Over FTG X C mfr# size webb# Copper Cross-Over FTG X C 78137 1/2” 216950 78142 3/4” 216951
Adapter Flange C X Flange mfr# size webb# Bronze Adapter Flange C x Flange 19728 21/2” 244807 19733 3” 244808 19738 4” 244809
Coupling C x C No Stop mfr# size webb# Copper Coupling C X C No Stop 78172 1/2” 216957 78177 3/4” 216958 78182 1” 216959 78187 11/4” 216960 78192 11/2” 216961 78197 2” 216962 XL Bronze Coupling C X C No Stop 91477 21/2” 244813 91482 3” 244814 91487 4” 244815
90° Elbow FTG X F mfr# size webb# 90° Bronze Elbow FTG X F 77577 1/2” X 1/2” NPT 216853
www.fwwebb.com
mfr# size webb# Copper 90° Elbow C X C Close Rough 77317 1/2” 216817 77322 3/4” 216818 77327 1” 216387 77332 11/4” 216388 77337 11/2” 216389 77342 2” 216819 XL Bronze 90° Elbow C X C Close Rough 91357 21/2” 244825 91362 3” 244826 91367 4” 244827
90° Elbow FTG X C Close Rough mfr# size webb# Copper 90° Elbow FTG X C Close Rough 77347 1/2” 216820 77352 3/4” 216821 77357 1” 216390 77362 11/4” 216391 77367 11/2” 216392 77372 2” 216822 XL Bronze 90° Elbow FTG X C Close Rough 91492 21/2” 244828 91497 3” 244829 91502 4” 244830
45° Elbow C X C mfr# size webb# Copper 45° Elbow C X C 77607 1/2” 216857 77612 1/2” 216858 77617 1” 216404 77622 11/4” 216405 77627 11/2” 216406 77632 2” 216859 XL 45° Bronze Elbow C X C 91417 21/2” 244822 91422 3” 244823 91427 4” 244824
(cont.)
45° Elbow FTG X C
Reducer FTG X C
mfr# size webb# 45° Copper Elbow FTG X C 77637 1/2” 216860 77642 3/4” 216861 77647 1” 216862 77652 11/4” 216863 77657 11/2” 216864 77662 2” 216865 XL 45° Bronze Elbow FTG X C 91537 21/2” 244819 91542 3” 244820 91547 4” 244821
mfr# size webb# Copper Reducer FTG X C 78077 3/4” X 1/2” 216940 78082 1” X 1/2” 216941 78087 1” X 3/4” 216942 78092 11/4” X 3/4” 216943 78097 11/4” X 1” 216944 78102 11/2” X 1” 216945 78107 11/2” X 11/4” 216946 78112 2” X 1” 216947 78117 2” X 11/4” 216948 78122 2” X 11/2” 216949 XL Bronze Reducer FTG X C 91462 21/2” X 2” 244831 91467 3” X 2” 244832 91472 3” X 21/2” 244833 91447 4” X 2” 244834 91452 4” X 21/2” 244835 91457 4” X 3” 244836
90° Elbow CXM mfr# size webb# 90° Bronze Elbow C X M 77492 1/2” X 1/2” NPT 216837 77497 1/2” X 3/4” NPT 216838 77502 3/4” X 1/2” NPT 216839 77507 3/4” X 3/4” NPT 216840 77512 1” X 1” NPT 216841 77517 11/4” X 11/4” NPT 216842 77522 11/2” X 11/2” NPT 216843 77527 2” X 2” NPT 216844
Reducer C X C mfr# size webb# Copper Reducer C X C 78147 3/4” X 1/2” 216952 78152 1” X 3/4” 216953 78162 11/2” X 11/4” 216955 78167 2” X 11/2” 216956
Union C X F 90° Elbow CxF mfr# size webb# 90° Bronze Elbow C X F 77532 1/2” X 1/2” NPT 216845 77537 1/2” X 3/4” NPT 216846 77542 3/4” X 3/4” NPT 216847 77547 3/4” X 1/2” NPT 216848 77552 1” X 1” NPT 216849 77557 11/4” X 11/4” NPT 216850 77562 11/2” X 11/2” NPT 216851 77567 2” X 2” NPT 216852
mfr# size webb# Bronze Union C X F 77752 1/2” X 1/2” NPT 216882 77757 3/4” X 3/4” NPT 216883 77762 1” X 1” NPT 216884 77777 2” X 2” NPT 216887
Union C x M mfr# size webb# Bronze Union C x M 77782 1/2” X 1/2” NPT 216888 77787 3/4” X 3/4” NPT 216889 77792 1” X 1” NPT 216890 77807 2” X 2” NPT 216893
Union C X C Elbow Drop 90° C X F w/ Wall Plate mfr# size webb# Bronze Elbow Drop 90° C X F With Wall Plate 77697 1/2” X 1/2” NPT 216872 77702 3/4” X 3/4” NPT 216873
The F.W. Webb Heating Catalog
mfr# size webb# Bronze Union C X C 77667 1/2” 216866 77672 3/4” 216867 77677 1” 216868 77682 11/4” 216869 77687 11/2” 216870 77692 2” 216871
13
Tee CxCxC mfr# size webb# Copper Tee C X C X C 77377 1/2” 216823 77382 1/2” X 1/2” X 3/4” 216824 77387 3/4” 216825 77392 3/4” X 1/2” X 1/2” 216826 77402 3/4” X 3/4” X 1/2” 216828 77407 3/4” X 3/4” X 1 216829 77412 1” 216393 77417 1” X 3/4” X 1/2” 216830 77422 1” X 3/4” X 3/4” 216831 77427 1” X 3/4” X 1” 216832 77432 1” X 1” X 1/2” 216833 77437 1” X 1” X 3/4” 216394 77442 11/4” 216395 77447 11/4” X 11/4” X 1” 216396 77452 11/4” X 11/4” X 3/4” 216397 77457 11/2” 216398 77462 11/2” X 11/2” X 3/4” 216399 77467 11/2” X 11/2” X 1” 216400 77472 11/2”X11/2”X11/4” 216401 77477 2” 216834 77482 2” X 2” X 11/2” 216835 77487 2” X 2” X 11/2” 216836 XL Bronze Tee C X C X C 91372 21/2” 244837 91402 11/2”X11/2”X2” 244840 91377 3” 244838 91407 3” X 3” X 2” 244841 91412 3” X 3” X 21/2” 244842 91382 4” 244839 91387 4” X 4” X 2” 244843 91392 4” X 4” X 21/2” 244844 91397 4” x 4” x 3” 244845
14 TOOLS
mfr# size 76807 ProPress Crimping Tool Only 76912 ProPress Crimping Tool with 1/2”, 3/4”, 1”, 11/4”, 11/2”, 2” Jaw Sets and Carrying Case
Power Tools
Tee C x C x F mfr# size webb# Bronze Tee C X C X F 77582 1/2”X1/2”X1/2” NPT 216854 77587 3/4”X3/4”X1/2” NPT 216855 77592 1” X 1” X 1/2” NPT 216402 77597 1 1/4 ”X1 1/4 ”X 1/2 ” NPT 216403 78342 11/2”X11/2”X1/2”NPT 216413 77602 2” X 2” X 1/2” NPT 216856 XL Bronze Tee C X C X F 91522 21/2”X21/2”X3/4” NPT 244846 91517 21/2”X21/2”X2” NPT 244847 91532 3” X 3” X 3/4” NPT 244848 91527 3” X 3” X 2” NPT 244849 91512 4” X 4” X 3/4” NPT 244850 91507 4” X 4” X 2” NPT 244851
F.W. WEBB COMPANY
207 3/24/08 11:47:27 AM
Screws & Drill Bits
Hole Saws
webb# 44200 42430 42433 42434 42435 42436 42437 42438 42439 42440 42441 42442 42443 42444 42445 42446 44038 42447 42448 42431 42449 44217 42450 42451 42452 42453 42454 42455 42456 42457 42458 44222
Plumbers Hole Saw Kit Mfr# size 600P Kit
208 14_Tools_p210.indd 208-209
webb# 44242
Wood Boring Bits
Mfr# size webb# 1L 7/16” X 9/16” 44033
Mfr# size WB100 1” WB112 11/8” WB125 11/4” WB137 13/8” WB150 11/2” WB175 13/4” WB200 2” WB212 21/8” WB256 29/16” 38L 23/8” 40L 21/2” 42L 25/8” 44L 23/4” 48L 3” 50L 31/8” 52L 31/4” 56L 31/2” 58L 35/8” 60L 33/4” 64L 4” 66L 41/8” 68L 41/4” 72L 41/2” 76L 43/4” 80L 5” 96L 6”
2L
7/16” X 11/4-6”
44034
4L
1/4” X 9/16”
44035
5L
3/8” X 9/16”
44036
6L
3/8” X 11/4-6”
44037
Hole Saw Accessories Mfr# size Arbor Adapter AA1
webb# 42478
Pilot Drill 4321 1/4” 56PD 1/4”
42477 44237
Extensions 55X 1/2” X 51/2” 12X 1/2” X 12” 18X 1/2” X 18”
42399 42480 42481
webb# 42366 42368 42370 42372 42373 42375 42378 42380 42384 42445 42446 42447 42448 42431 42449 44217 42450 42451 42452 42453 42454 42455 42456 42457 42458 44222
SECTION
14
14
Automatic Feed Wood Bits Mfr# size LL100 1” LL112 11/8” LL125 11/4” LL137 13/8” LL150 11/2” LL175 13/4” LL200 2” LL212 21/8” LL225 21/4” LL256 29/16”
webb# 150057 150058 150059 150063 150064 150065 150060 150061 150062 150066
Ship Auger Bits Mfr# size webb# 29102 5/16” 222418 31007 7/16” 244034 31006 3/8” 244033 31008 1/2” 244035 31034 7/8” 225053 31016 1” 225050 31012 3/4” X 18” 241640 31015 15/16” X 18” 241641
Wood Bit Kit Carbide Tip Hole Saws Mfr# size 12CT 3/4” 14CT 7/8” 16CT 1” 18CT 11/8” 20CT 11/4” 24CT 11/2” 28CT 13/4” 32CT 2” 34CT 21/8” 36CT 21/4” 40CT 21/2”
F.W. WEBB COMPANY
webb# 74573 74574 74575 74576 74577 74579 74581 74582 74583 74584 74585
Mfr# size 32500 6 Sizes
12” Hacksaw Blades
Blades
Reciprocating Blades Mfr# size #TEETH webb# 5 Per Vinyl Pouch 656R 6 X 3/4 6 42467 156R 12 X 3/4 6 42469 956R 9 X 3/4 6 44032 634R 9 X 3/4 4 205647 110R 12 X 3/4 10/14 44188 636RP 6 X 3/4 6 42463
676RC 6 X 7/16 6 314RC 3 X 1/4 14 318RC 3 X 1/4 18 606R 610R 810R 414R 614R 418R 618R 818R 424R 624R
6 X 3/4 6 X 3/4 8 X 3/4 4 X 3/4 6 X 3/4 4 X 3/4 6 X 3/4 8 X 3/4 4 X 3/4 6 X 3/4
6 10 10 14 14 18 18 18 24 24
44031 205646 42459 44187 42464 42468 42460 42465 42461 42432 85478 42462 42466
Mfr# size V218HE 18T V224HE 24T V232HE 32T
Mfr# size HSB12 12” HSB18 18”
webb# 44298 44299 44300 154084 166280 71894
9 X 7/8 9 X 7/8
6 10
165149 95599
650R 6510R 6514R 6118R
6 X 3/4 10/14 6 X 3/4 10 6 X 3/4 14 6 X 3/4 18
166279 205648 205649 264371
Mfr# size HSF12 12” HSF18 18”
webb# 44039 44040
ProTool Lubricant
Pilot Screws Mfr# Desc. webb# WBPS 5 In A Bag 42393
www.fwwebb.com
webb# 42475 42476
PVC/ABS Blades With Handle
Mfr# size # teeth webb# 2 Per Vinyl Pouch 800RG 8 X 3/4 carbide 56262 966G 960G
webb# 42470 42471 42472
PVC/ABS Blades
Reciprocating Blades
webb# 73314
Vari Bit Mfr# size VB1 1/8” - 1/2” VB2 1/4” - 1” VB3 1/4” - 3/4” VB4 3/16” - 1/2” VB8 3/16” - 7/8” VB12 7/8” - 13/8”
Screws & Drill Bits
The F.W. Webb Heating Catalog
Mfr# webb# 68040 164075
Screws
13
mfr# desc. Pkg. QTY webb# Speed Screws 10602 6” X 3/8” 100 58731 11002 7” X 1/2” 100 58732 11032 8” X 1” 100 58733 11040 8” X 11/4” 100 58734 11052 8” X 11/2” 500 49290 11048 8” X 11/2” 250 49289 11058 8” X 2” 100 58735 11078 10” X 3/4” 100 58737 11082 10” X 3/4” 1,000 162356 11086 10” X 1” 100 58736 Plastic Anchor Kits 12502 3/16” X 7/8” 155169 12500 3/16” X 3/4” 155168 12506 1/4” X 1” 49291 Jiffy Point Screws 11012 8” X 1/2” 100 49285 11014 8” X 1/2” 500 78999 11016 8” X 1/2” 1,000 49286 11010 8” X 1/2” 15,000 163406 11022 8” X 3/4” 100 49287 11024 8” X 3/4” 500 79000 11026 8” X 3/4” 1,000 49288 11020 8” X 3/4” 10,000 151371 Jiffy Drill Tip Screws 11202 8” X 1/2” 100 58738 11204 8” X 1/2” 500 79001 11222 8” X 3/4” 100 58739 11224 8” X 3/4” 500 78053 11264 10” X 3/4” 7,000 112685 11268 10” X 3/4” 500 112684 11206 10” X 3/4” 500 155272 Jiffy Chuck 10016 1/4” 49284 10022 5/16” 91413
14 TOOLS
Mfr# size 10L 5/8” 12L 3/4” 14L 7/8” 16L 1” 18L 11/8” 20L 11/4” 22L 13/8” 24L 11/2” 26L 15/8” 28L 13/4” 30L 17/8” 32L 2” 34L 21/8” 36L 21/4” 38L 23/8” 40L 21/2” 41L 29/16” 42L 25/8” 44L 23/4” 48L 3” 50L 31/8” 52L 31/4” 56L 31/2” 58L 35/8” 60L 33/4” 64L 4” 66L 41/8” 68L 41/4” 72L 41/2” 76L 43/4” 80L 5” 96L 6”
Bits
Hole Saw Arbors
SECTION
F.W. Webb stocks superstor water heaters and indirects!
F.W. WEBB COMPANY
209 3/24/08 11:47:29 AM
SECTION
14
Screws & Drill Bits Saw Blades Wood Bits mfr# size Webb# Auger Bits 48-13-0870 48-13-1120 48-13-1250 48-13-1370 48-13-1500 Selfeed Bits
7/8” 11/8” 11/4” 13/8” 11/2”
48-25-1002 1” 48-25-1122 11/8” 48-25-1252 11/4” 48-25-1372 13/8” 48-25-1502 11/2” 48-25-1752 13/4” 48-25-2002 2” 48-25-2122 21/8” 48-25-2252 21/4” 48-25-2562 29/16” 48-25-3001 3” 48-25-3621 35/8” 48-25-4621 45/8” Bellhanger Bits
13250 13259 13261 13263 13265
53600 53601 53602 53603 53604 53605 53606 53607 53608 53609 53610 53611 53612
48-13-7125 1/4” X 12” 67729 48-13-7225 1/4” X 18” 67723 48-13-7325 1/4” X 24” 67727 Twist Drill Bits 48-89-1535 48-89-0171 48-89-1545 48-89-1203 48-89-0218 48-89-0234 48-89-1565 48-89-0265 48-89-0281 48-89-0296 48-89-0328 48-89-0343 48-89-1605 48-89-0390 48-89-0406 48-89-0421 48-89-1625 48-89-0453 48-89-0468 48-89-0484 48-89-0500 48-89-1645
5/32” 11/64” 3/16” 13/64” 7/32” 15/64” 1/4” 17/64” 9/32” 19/64” 21/64” 11/32” 3/8” 25/64” 13/32” 27/64” 7/16” 29/64” 15/32” 31/64” 1/2” 1/2”
74659 74660 74661 74662 74663 74664 74665 74666 74667 74668 74670 74671 74673 74674 74675 74676 74677 74678 74679 74680 74681 247642
mfr# size Webb# Extension Assemblies
mfr# size Webb# Band Saw Blade 48-39-0520 18 Teeth 91044
53613 53614 53615 53616
Carbide Tipped Circular Saw Blade 48-40-4015 48 Teeth 252040
48-28-4001 51/2” 48-28-4006 12” 48-28-4011 18” 48-28-4016 24” Twist Drill Bit Cards/2
48-89-1520 7/16” 74656 48-89-1525 1/8” 74657 48-89-1530 9/64” 74658 48-89-1505 1/16” 74682 48-89-1510 5/64” 74683 48-89-1515 3/32” 74684 Drill Bit Set — 20 Piece 48-89-1105 240499
Rotary Hammer Bits mfr# size 2/Card
Webb#
48-20-4126 11/4” X 22” 111414 48-20-4151 11/2” X 22” 111415
Abrasive Wheel 49-94-1405 14”
53595
Kits mfr# dESC. WEbb# Contractor Bit Kit 49-22-0130 201846
Plumbers Bit Kit 49-22-0065
13283
Hole Saw Kit 49-22-4065
13 Piece
42273
Hole Saw Kit 49-22-4070
7 Piece
42274
Masonry Bits mfr# size 2/Card 48-87-8810 1/4” 48-87-0370 3/8” X 4” 48-87-8830 1/2” X 6”
Phillips Bits #2 — 10 Pk.
mfr# Webb# 48-32-1053 240500
Webb#
Accessories 54322 132630 132633
mfr# dESC. WEbb# Rubber Flex Key Holder 48-66-4040 13282 48-66-4080 54325 Key Chuck 48-66-3350 53597 Quick Change Chucks 48-03-0006 48-66-1360 1/2” Reverse Drill Chuck
111677 132432
Screw Guide 48-32-3020
240498
48-32-1043 252620
Rotary Hammer Chisels mfr# 48-62-2020 48-62-2000
210 14_Tools_p210.indd 210
description Webb# 12” Cold Chisel 83659 12” Bull Point Chisel 111416
F.W. WEBB COMPANY
www.fwwebb.com
3/24/08 11:47:32 AM
SECTION
15
Power Venters & Draft SWG Power Venter Outdoor Mounted Power Venters for Oil & Gas
Stainless Steel Model Shown
The SWG is the safest, most efficient power venter available today. It combines the motor, blower, and vent hood in one complete, easy to install unit that significantly reduces motor noise. The SWG utilizes 100% negative pressure to effectively vent oil and gas-fired furnaces, heaters, boilers, gas-fired water heaters, and fireplaces through the sidewall. Models are available for residential, commercial, and industrial use. Some models are CSA listed and AGA approved. All are ETL listed. The standard SWG Power Venter is designed for walls up to 8” thick. PEK extension kits allow the SWG to be installed in walls up to 16” thick. The PEK kit includes the inner/ outer pipe extension, air flow damper, and one foot of 1/4” aluminum tubing. It is available for models SWG-4 through SWG-8.
15
When to use the SWG:
Specifications Model SWG3 SWG4HD SWG4HDS SWG5 SWG5SS† SWG6 SWG8
Volts 115 115 115 115 115 115 115
†
A 3” 4” 4” 5” 5” 6” 8”
B 5” 6” 6” 7” 7” 8” 10”
C 91/16” 113/4” 113/4” 113/4” 113/4” 113/4” 113/4”
D E 81/2” 75/8” 91/2” 9” 91/2” 9” 103/4” 12” 103/4” 12” 103/4” 12” 117/8” 13”
venting
For use with oil or gas furnaces, boilers, and water heaters. • New construction. • When converting from electric to gas or oil. • To avoid relining a chimney. • When installing an additional heating appliance. • When co-venting a water heater with a furnace. Stainless Steel Model
F webb# 93/16” 54237 9” 68338 9” 250727 121/4” 54239 121/4” 217157 121/4” 54240 141/4” 54240
Sizing the Venter – Use Maximum BTU or GPH Input
MODEL SWG-3
MAX* OIL GPH INPUT
MAX** GAS BTU/HR. INPUT
N/A
70,000
SWG-4HD, 4HDS 1.10
170,000
SWG-5, 5S 1.85
290,000
SWG-6 2.65
416,000
SWG-8 4.75
740,000
MAXIMUM EQUIVALENT FEET OF VENT PIPE AT MAX BTU/HR. INPUT
AT 60% OF MAX BTU/HR. INPUT
VENT PIPE SIZE
21
80
3”
50
100
4”
35
100
4”
65
100
5”
100
100
6”
100
100
7”
16
44
4”
51
100
5”
95
100
6”
100
100
7”
28
78
5”
68
100
6”
100
100
7”
26
72
7”
51
100
8”
70
100
9” * Larger sizes available
The F.W. Webb Heating Catalog
F.W. Webb Company
211
Power Venters & Draft
SECTION
SECTION
15
15
Power Venters & Draft
Combustion Air & Venting for Oil Application
Vent Hoods
ComboVent™
All Field Vent Hoods are made of heavy gauge aluminum and can be used with natural gas, LP gas or oil fired equipment. There are five diameters ranging from 3 to 8 inches. The concentric pipe, angled outlet deflectors and spaced plate design allow for better heat dissipation. This type of construction minimizes the effects of heat on the outside wall. The angled hood design reduces the effects of wind on the venting system. The inner and outer pipe are a continuous structure. This allows for easy installation to power venter or vent pipe and also eliminates possible positive pressure leaks in the wall section. Field Vent Hoods meet the highest standards for safety and reliability, built in accordance with guidelines from NFPA211, NFPA54 and ANSIZ21.47.
Features • Telescoping stainless steel body, accommodates walls up to 14” thick. • Combustion air connection included, provides fresh air directly to burner, coupler rotates 360º for easy installation. • Two piece backing plate, can be mounted at any point during installation, easier to service. • Slotted hood with larger screws, saves time during annual service. • Quick-connect electrical coupling, allows for easy motor access.
CV-4 1.10
.90
VENT PIPE SIZE
35
100
4”
65
100
5”
100
100
6”
100
100
7”
16
44
4”
CV-5 1.85
AT 60% OF MAX INPUT
AT MAX INPUT
51
100
5”
95
100
6”
100
100
7”
1.55
WEBB#
Vent Hood
PVO-300
1.00
1.50
287
150
75
2.25
Webb#
5”
257
6”
346
120
51
179170
172
70
Control Kits (CK) control the operation of SWG Power Venters. See the chart below to select the proper kit for your application. Control Kits are included with the models shown. Control Kits can also control the operation of Field Draft Inducers. Mfg# desc. CK-62 Oil CK-61 Oil CK-20F Gas – 30 mv CK-21 Gas – 30 mv CK-41F Gas – 24V CK-43 Gas – 24V CK-92F Gas – Co-venting multiple appl.
Dia.
145,000
220,000
310,000
Webb#
4”
305
145
64
179169
5”
247
100
54
6”
334
147
74
UNIT DIMENSIONS (INCHES) Model PVG/PVO-300
212
F.W. Webb Company
HEIGHT
WIDTH
DEPTH
OUTLET
7.5
9.25
7.00
4.00
webb# 54247 54246 54243 68339 54245 90732 57567
CK Control Kit
Maximum equivalent horizontal pipe length (feet) BTU/HR Input
PVG-300
15
Required to Operate SWG Power Venter
PVG—Gas & PVG PAK
Model
webb# 46390 45119 45120 46391
Control Kits
0.75
PV Power Venter
Dim. F 75/8” 105/8” 105/8” 105/8”
379341
Maximum equivalent horizontal pipe length (feet) GPH Input 0.50
Dim. E 87/8” 125/8” 125/8” 125/8”
• PVG Power Venter. • PVO Power Venter. • Forced Draft System.
PVO—Oil
0.40
Dim.D 43/8” 65/16” 8” 8”
For use with:
The indoor mounted PVG and PVO Power Venters provide an economical power venting system for gas and oil appliances. All controls are built into these units. A Vent Hood is required to terminate the vent system.
4”
Dim.C 81/2” 81/2” 81/2” 81/2”
* Larger sizes available
Indoor Mounted Power Venters for Oil & Gas
Dia.
Dim.B 5” Dia. 6” Dia. 8” Dia. 8” Dia.
372649
PV Power Venters
Model
Dim. A 3” Dia. 4” Dia. 5” Dia. 6” Dia.
mfg# Oil CK-62 CK-61 Gas CK-20F CK-21 CK-41F CK-43 CK-92F
Draft Proving Switch Gas Pressure Switch Secondary Safety Switch Thermal Post Purge Adjustable Electronic Post Purge Fixed Post Purge Draft Control
MAX oil GPH input 140 psi
Model # SWH3 SWH4 SWH5 SWH6
venting
MODEL
MAX OIL GPH INPUT 100 PSI
MAXIMUM EQUIVALENT FEET OF VENT PIPE
Application All oil fired systems. Thermally activated post purge. All oil fired systems. Adjustable post purge.
x x
x x x x
30 millivolt or 750 millivolt gas fired water heaters and gas fired pool or spa heaters with a manual or internally mounted thermostat. Gas fired instantaneous water heaters with a pressure tap port in the burner manifold. Furnaces, boilers, unit heaters and water heaters operating with a 24 VAC gas valve without factory mounted spillage switches. Draft induced 24 VAC gas valve systems. Includes a 4” MG-1 draft control and post purge. Gas fired furnace or boiler and a 30 millivolt operated water heater. Includes post purge.
x x
x
x x x
x
x
x
x
x x x
x
x
* Control Kits are ETL approved accessories when used in conjunction with the SWG Power Venter. F = Fixed Post Purge
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
213
Power Venters & Draft/Combustion Air
SECTION
SECTION
15
15
Power Venters & Draft/Combustion Air
Air Boosters
When to use an Air Booster:
Combustion Air System
Type AB
• When a room is too hot or too cold. • To improve air delivery to any room in a home or office. • Bad air flow to room additions. • On undersized branch ducts.
CAS-6, CAS-7
• Attaches to any size vent. • Automatic operation. • Adjustable control.
The Fan-in-a-Drum® is a commercial product designed to deliver combustion air into the mechanical room, boiler room or furnace location to overcome a confined space or inadequate air supply. CAS 6 & 7 are dual volt units for oil or gas applications.
electrical data Model
Volts (AC)
AB-6
.6
120
AB-8
Air Booster
Amps
.8
Hz
60
Watts
35 45
RPM
Thermal impectance protection
3000
Yes
maximum temp rating
air flow capacity cfm up to
Webb#
180
225
40470
160
425
49471
How the CAS-6 and CAS-7 work: When the thermostat calls for heat, the Fan-in-aDrum® engages and begins drawing outside air into the structure. When air flow is established, the CAS allows the burner to activate. The Fan-in-a-Drum® diffuses the outside air into the room near the burner to ensure air supply and promote efficienct combustion.
Combustion Air System Direct Connect The Field Combustion Air System (CAS) provides controlled amounts of outside air for proper combustion of oil or gas heating appliances. There are CAS models designed to work with a variety of gas or oil appliances, including models designed specifically for use with Beckett, Carlin, Wayne, Aero and Weil-McLain burners. Model CAS1 CAS2B CAS2C CAS2B-90E
Fuel Oil Oil Oil Oil
Burner Beckett AFII Beckett AFG or AF Carlin EZ-1, CRD, FRD Beckett AF/AFG
Appliance Input Up to 2 gph Up to 2 gph Up to 2 gph Up to 2 gph
Components webb# 4” Intake Air Hood 94164 4” Vacuum Relief Valve Field AirBoot® 94165 ® Field AirBoot 94166 For Furnaces 242091
When to use the CAS:
Fan-in-a-Drum Assembly
Model# CAS-6 CAS-7
CAS-6 OIL (GPH)
CAS-6 GAS (BTU/HR)
8” DUCT
10” DUCT
CAS-3, CAS-4
Intake Air Hood
These models are designed to provide combustion air for appliances when direct connection to the burner is not possible. According to NFPA 54-5.3.4, an Engineered system such as a CAS-3 or CAS-4 may be used to overcome a confined space. The CAS-3 is designed for use with oil appliances. The CAS-4 is for use with gas appliances with 24 VAC gas valve controls. Each is designed for optimum safety and includes a proving device that won’t allow the burner to engage without incoming air flow. Multiple units or additional controls are required for multiple appliance installations. Each is equipped with a two speed control for enhanced versatility.
Fan-in-a-Can Assembly
Model CAS3 CAS4
Fuel Burner Appliance Input Oil Any oil heating Up to 3.25 gph applicance Gas Any gas heating Up to 450,000 24v applicance BTU/HR
Components webb# 4” Intake Air Hood Fan-In-Can 94168 Assembly 6” to 4” Reducer Restrictor Plate 4” Intake Air Hood Fan-In-Can 94169 Assembly 6” to 4” Reducer Restrictor Plate
MAX. EQUIVALENT LENGTH OF PIPE, INCLUDING STARKAP® CAS-7 OIL (GPH)
CAS-7 GAS (BTU/HR)
10” DUCT
12” DUCT
3
420,000
410
1253
6
840,000
469
1167
3.25
455,000
344
1051
6.5
910,000
381
948
3.5
490,000
291
890
7
980,000
311
776
3.75
525,000
249
760
7.5
1,050,000
256
637
4
560,000
214
653
8.25
1,155,000
191
476
4.25
595,000
185
584
9
1,260,000
142
354
4.5
630,000
160
489
9.75
1,365,000
104
260
4.75
665,000
139
424
10.5
1,470,000
74
186
5
700,000
121
369
11.25
1,575,000
51
127
5.25
735,000
105
321
12
1,680,000
31
78
5.75
805,000
79
241
12.75
1,785,000
15
39
6.25
875,000
58
176
12.88
1,803,000
13
33
6.50
910,000
49
151
F.W. Webb stocks sterling baseboard!
Optinal Multiple Applicance Control for use with CAS-3 or CAS-4 Fan-in-a Can Model# HWK
Description Webb# Fan-in-a-Drum® 360684 255944 Fan-in-a-Drum®
MAX. EQUIVALENT LENGTH OF PIPE, INCLUDING STARKAP®
• Too tight construction. • Provide source of fresh air for combustion. • CAS-1 and CAS-2 connect directly to oil burners. • CAS-3, CAS-4 are for multiple appliances or when direct cconnection is not possible.
venting
CAS1, CAS-2B&C
15
Description Webb# Additional water heater control with CAS-4 45536
How the CAS-3 and CAS-4 work: When the thermostat calls for heat, the Fan-in-a-Can™ engages and begins drawing outside air into the structure. When air flow is established, the CAS allows the burner to activate. They diffuse the outside air into the room near the burner.
214
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
215
Power Venters & Draft/Combustion Air
SECTION
SECTION
15
15
Make-Up Air System
Draft Controls
Whole House Make-Up Air System
Type RC Oil or Coal – Residential and Commercial
The Field Make Up Air System solves the “sick house syndrome” caused by too tight home construction. This unique system provides fresh air automatically, using no electricity or special controls. And it actually meters the air flow to keep the home balanced. No negative pressure. No rushes of cold air in winter, hot air in summer. The result is evenly distributed, tempered air that keeps the home fresh, the furnace efficient and the occupants comfortable. The Field Metering Air System consists of an Intake Air Hood which is installed through the wall to allow outside air in. The hood is connected via flexible 6” duct or standard duct pipe (not included) to our metering air device. This device effectively meters the air inflow for proper air circulation, combustion, and balance.
RC — Draft Control
When to use the IAH: • Improve IAQ (Indoor air quality). • Stale air problems. • Too tight house construction. • Inadequate air changes. • Window condensation problems.
DI Series Field Draft Inducers solve the drafting problems caused by short chimneys, undersized flue pipes and negative building pressures. Draft Inducers are designed for easy installation in a wide variety of applications, including oil or gas fired furnaces, water heaters, and boilers. For venting a single appliance, a Draft Inducer Proving Switch (DIP-1) is recommended.
Draft Inducer
When to use a draft inducer: • • • •
Long horizontal vent runs. Undersized flue pipes. Short chimneys. Outside exposed chimney.
pipe dia (in.)
draft inducer (model)
static pressure (in w.c.)
gas firing with barometric draft control input (BTU-HR)
pipe dia (in.)
47
69,000
3
72
105,000
4
75
118,000
5
flow (CFW)
draft inducer (model)
static pressure (in w.c.)
flow (CFW)
input (BTU-HR)
pipe dia (in.)
36
72,000
3
55
96,000
4
65
134,000
5
draft inducer (model)
static pressure (in w.c.)
flow (CFW)
69,000
3 4
111,000
5
120,000
6
.05
82
123,000
6
.05
68
136,000
6
.04
68
279,000
5
.06
190
300,000
5
.07
156
312,000
5
.06
156
308,000
6
.07
210
340,000
6
.08
176
350,000
6
.07
175
330,000
7
.11
225
364,000
7
.09
189
400,000
7
.08
200
353,000
8
.07
240
390,000
8
.06
200
430,000
8
.05
215
522,000
8
.18
683,000
8
.15
355
710,000
8
.13
355
.15
880,000
9
.13
458
916,000
9
.12
908,000
10
.10
472
944,000
10
.08
1,092,000
12
.06
568
1,236,000
12
674,000
9
694,000
10
835,000
12
216
DI-1
DI-2
DI-3
.06
F.W. Webb Company
.05 DI-1
DI-2
DI-3
.06
Dia.
circum.
4RC
4
3-4-5
91/2 - 153/4
94552
5RC
5
4-5-6
121/2 - 19
45129
6RC
6
5-6-7
153/4 - 22
9771
7RC
7
6-7-8
19 - 251/4
9772
8RC
8
7-8-9
22 - 281/8
9773
9RC
9
8-9-10
251/4 - 311/2
9774
MG-1 — Draft Control
A double-acting control for gas fired furnaces and boilers is widely used for conversion burner installations, gas draft-induced appliance operation with mechanical draft inducers or sidewall power venters. It is also recommended for use on gas atmospheric appliances where a draft hood cannot be installed, and can improve combustion stability and draft on many gas atmospheric installations with venting problems.
DI-1
DI-2
DI-3
48 67
.11
458
.09
472
.06
568
recommended pipe sizes
Control size
Dia.
circum.
Webb#
4-MG1
4
3-4
91/2 - 121/2
153629
6-MG1
6
5-6
153/4 - 19
68751
7-MG1
7
6-7
19 - 22
88842
8-MG1
8
7-8
22 - 251/4
163328
Webb#
recommended pipe sizes
Control size
Dia.
circum.
Webb#
10MMG2
10
9-10
281/4 - 311/2
70292
12MMG2
12
11-12
341/2 - 373/4
70293
MFR#
36 .05
Webb#
MFR#
oil or gas firing with barometric draft control
105,000
.04
Control size
MFR#
Type M+MG2 Solid, Oil or Gas Commercial/Industrial
Sizing Specification Chart gas firing with hood draft
recommended pipe sizes
Type MG-1 Gas
Draft Inducers
MFR# Description Webb# DIP1 Draft Inducer Proving Switch 45115
The Field RC is furnished as standard equipment on many leading brands of oil or coal fired heating equipment. It is calibrated to allow for easy adjustment to the furnace or boiler manufacturer’s specifications. Designed for settings from .02” to .08”, this control is so sensitive that instrumentation should be used when adjusting the unit during installation.
45112
F.W. Webb stocks: 45113
45114
www.fwwebb.com
boilers!
The F.W. Webb Heating Catalog
F.W. Webb Company
217
15 venting
mfr# description webb# IAH4 4” Air Intake Hood 94172 IAH6 6” Air Intake Hood 94173
input (BTU-HR)
Power Venters & Draft Regulators
Power Venter Parts & Controls
SECTION
SECTION
15
15
Power Venters
Replacement Parts mfr# description Model HWK Power Venter Accessories 46086400 GSK-3 Spillage Switch Kit
SWG Series Power Venter Motor Assemblies SWG4RMK Replacement Motor Assembly Old Style SWG4HDRMK Universal Replacement Motor Assembly — SWGII4, SWG4HD SWG5RMK Universal Replacement Motor Assembly SWG6RMK Universal Replacement Motor Assembly
Tjernlund Power Venters SideShot® Series Models SS1, SS2, SS1C
webb#
The SideShot® models SS1 and SS2 SideWall Vent Systems include the UC1 Universal Control for increased safety, performance and reliability. Designed for oil fired heating equipment or a deluxe gas vent system. Patented vent termination propels flue gases at high velocities away from the building exterior, a necessity when venting oil fired equipment. Both models can be installed with zero clearance to combustible materials and have stainless steel construction in critical areas. Factory wired safety and operating controls allow for simple interlock with any burner. The new model SS2 features a selfcleaning stainless steel, backward inclined impeller and sealed ball bearing motor for virtually maintenance free installations. Ultra-fine draft adjustment and slide-out access to all internal components.. Easy multiple appliance interlocks with our MAC-Series Multiple Appliance Controls.
46389
69936 69937 69938 94163
CK-91 Gas Fired Appliance and Water Heater Combination Kit 46273100 24 Volt Pressure Switch 84511 46144700 Post Purge Timer/Relay 82654 46082700 TCA-1 Thermocouple Adapter 72434
Verify that the total BTU/hr input of the heating appliance(s) fall within the proper category listed below. Please note the capacity differs between the SS1, SS1C and SS2. To determine equivalent feet, add the total length of straight vent pipe plus 10 feet for each 90 degree elbow and 5 feet for each 45 degree elbow. Vent runs over 15 linear feet should use an approved, insulated vent connector to prevent problems related to condensation. Multiple appliance interlocks require the use of our MAC-Series Multiple Appliance Controls. The SS1 & SS1C feature a bottom or rear vent connection. The inlet collar accepts any brand or type of 6” diameter vent pipe.
CK-62 120 VAC Oil Fired Control Kit 46111100 120 Volt Relay 46086900 WMO-1 Secondary Safety Switch
Accessories for Draft Inducers and Control Kits 46080200 24 Volt SPDT Relay
SS1 Capacity 45127 45118
model SS1
Natural and lp gas
flame retention oil burner
conventional oil burner
max. equivalent feet
Webb#
50,000-160,000 BTU/hr
50,000-220,000 BTU/hr 1.55 gal/hr max.
50,000-180,000 BTU/hr 1.25 gal/hr max.
50 feet
95504
SS1C Capacity (For larger residential and commercial applications) 45116 model
flame retention oil burner
conventional oil burner
max. equivalent feet
WEBB#
50,000-315,000 BTU/hr 2.25 gal/hr max.
50,000-223,000 BTU/hr 1.59 gal/hr max.
50 feet (15.2 meters)
379226
SS1C
CK-61 Adjustable Oil Control 46144700 Post Purge Timer Relay
82654
SideShot® Model SS2 Application Tables Verify that the total BTU/hr input of the heating appliance(s) fall within the proper category listed below. Please note the capacity differs between the SS1, SS1C and SS2. To determine equivalent feet, add the total length of straight vent pipe plus 10 feet for each 90 degree elbow and 5 feet for each 45 degree elbow. Vent runs over 15 linear feet should use an approved, insulated vent connector to prevent problems related to condensation. Multiple appliance interlocks require the use of our MAC-Series Multiple Appliance Controls.
SWG SuperLube This specially designed synthetic lubricant provides quality protection for all SWG Power Venters and other sleeve bearing motors. Lubrication with SWG Superlube protects the motor at operating temperatures from -40º F to 300º F. Adding just 4 to 6 drops a year increases the life of the motor by up to 5 times. SWG SuperLube
218
model SS2
MFR# WEBB# SWGLUBE 90126
F.W. Webb Company
SS2 Capacity Natural and lp gas
flame retention oil burner
conventional oil burner
max. equivalent feet
Webb#
70,000-168,000* BTU/hr
40,000-150,000 BTU/hr
40,000-125,000 BTU/hr
50 feet
197949
* Maximum capacity based on 13% Co2 and Max. 500ºF. inlet temperatures. Consult factory for details.
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
219
venting
SideShot® Model SS1 Application Tables
15
Power Venters
SECTION
SECTION
15
15
Power Venters
Tjernlund Power Venters (continued)
Tjernlund Power Venters (continued)
The SideShot Series is recommended for oil applications. We recommend the use of our HS-Series venters for oil burner inputs larger than the SideShot® Vent System capacities. For Sidewall venting residential/light commercial natural gas, LP or oil fired equipment including: Furnaces, boilers, water heaters and unit heaters. All models feature the new UC1 Universal Control and a diaphragm Fan Proving Switch safety interlock which will shut down heating equipment if a venting malfunction occurs. Built-in adjustable damper also allows regulation for maximum combustion efficiency. UC1 Universal Control features include; adjustable pre and post-purge settings, LED Status/diagnostic indicators, Fan Prover switch monitoring. Interlocks with any 24-120 VAC burner control circuit and also includes “dry” contact actuation option. Easily interlock multiple appliances with our MAC-Series Multiple Appliance Controls.
Used for Side wall venting commercial natural gas or LP fired equipment including: boilers, water heaters and unit heaters. All models feature the new UC1 Universal Control and a diaphragm Fan Proving Switch safety interlock which will shut down heating equipment if a venting malfunction occurs. UC1 Universal Control features include; adjustable pre and post-purge settings, LED Status/diagnostic indicators, Fan Prover switch monitoring. Interlocks with any 24-120 VAC burner control circuit and also includes “dry” contact actuation option. Easily interlock multiple appliances with our MAC-Series multiple appliance controls. Allows for a significant reduction in vent pipe diameter to save on costly materials and labor. Built-in adjustable damper also allows regulation for maximum combustion efficiency.
HS Series Models HS1 & HS2
HS Series Commercial Models: HS3
®
vent pipe model dia.
btu/ hr input
MAX. PIPE LENGTH (FEET) AT STACK TEMP. GAS FIRED 300ºF
*HS1
150,000
100’
4”
6”
*HS2
6”
8”
MAX. PIPE LENGTH (FEET) AT STACK TEMP. GAS FIRED 400ºF
MAX. PIPE LENGTH (FEET) AT STACK TEMP. OIL FIRED 500ºF
60’
35’
200,000
87’
57’
27’
250,000
40’
12’
—
300,000
4’
—
—
150,000
100’
100’
100’
200,000
100’
100’
100’
250,000
100’
92’
—
300,000
30’
—
—
350,000
100’
100’
100’
400,000
100’
100’
100’
450,000
100’
100’
67’
500,000
100’
72’
67’
550,000
94’
—
—
600,000
15’
—
—
350,000
100’
100’
100’
400,000
100’
100’
100’
450,000
100’
100’
100’
500,000
100’
100’
—
550,000
100’
—
—
600,000
67’
—
—
CFM AT 70ºF (Static Pressure) model .0”
.50”
.75”
1.0”
1.4”
WEBB#
*HS3 115 VAC 1/4 HP 2.7 AMPS
158
115
95
12
—
163813
vent pipe dia.
8”
10”
btu/hr input
MAX. PIPE LENGTH (FEET) AT STACK TEMP. 100% DILUTION 300ºF GAS FIRED ATMOSPHERIC WITH DRAFT HOOD OR DRAFT DIVERTER
MAX. PIPE LENGTH (FEET) AT STACK TEMP. 25% DILUTION 400ºF GAS FIRED POWER BURNER WITH BAROMETRIC DRAFT CONTROL
450,000
100’
100’
500,000
100’
100’
600,000
100’
100’
700,000
7’
100’
450,000
100’
100’
500,000
100’
100’
600,000
100’
100’
700,000
21’
100’
WEBB#
163812
Table is based on straight vent pipe. 90 degree elbows are equivalent to 10 feet of straight vent pipe, 45 degree elbows are equivalent to 5 feet of straight vent pipe. Tjernlund Commercial Power Vent Systems include all necessary actuation, operation and safety controls. Tjernlund’s Fixed & Variable Speed Specified Systems are also available with virtually unlimited capacities.
VH1-Series Models: VH1-4, VH1-6, VH1-8
286
235
215
196
158
329222
Specially designed to terminate Tjernlund Side Wall Vent Systems. They are also an approved method of terminating many horizontally vented appliances. Vent hoods feature heavy duty, corrosion resistant aluminum construction. Models VH1-4 and 6 also have an additional heat shield for built in clearances from combustibles. Building exteriors are kept clean while the aesthetics of the structure remain undisturbed. All mounting hardware is included. Model# VH1-4 VH1-6 VH1-8
Description Webb# 4” Vent Hood 163824 6” Vent Hood 163825 8” Vent Hood 379223
* Oil applications must use the SideShot® Vent Systems or HSJ, HS1, HS2 models including UC1 Universal Control with integral Pre and Post-Purge settings.
220
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
221
venting
Model Selection Table
HS-Series Residential/Light Commercial
15
Power Venters
SECTION
SECTION
15
15
Power Venters Parts
Tjernlund Power Venters (continued)
Tjernlund Power Venters (continued)
The UC1 is the new standard interlock control for Tjernlund’s full line of Fixed Speed Power Venters, Draft Inducers and Combustion Air In-Forcers. It can be interlocked with virtually any burner control circuit. Features include: adjustable pre & post purge, LED status/diagnostic indicators, 10 second prover switch delay to avoid burner start up and wind induced short cycling. Interlocks with any 24-120 VAC burner control circuit and also includes “dry” contact actuation option. Selectable voltage eliminates false activation by burner control circuits. After each burner cycle the UC1 will continue to operate in post-purge mode to allow the venter to purge the heater and vent of residual flue gases. A factory post-purge time is set at 2 minutes and is adjustable up to 16 minutes.
part# 950-0670 950-8804 950-0650 950-0640 950-0625 950-0635 950-0016
UC1 Universal Control
Side Wall Vent Systems Parts
The UC1 Universal control is standard in the following models: HSJ, HS1, HS2, HS3, HS4, HS5, SS1, SS1C, SS1R, SS2
* Replacement motors on SS1 with Date codes prior to 26/92 must order entire plenum section.
Power Venter Parts
Description Webb# Interlock Control 379225
MAC1E Multiple Appliance Control Used in conjunction with the UC1 Universal Control to easily interlock up to one additional 24 VAC, 115 VAC or millivolt controlled appliance with Fixed Speed Auto-Draft Inducer, Power Venters (Gas, Oil), Draft Inducers, or In-forcers. It activates the Venter through its connections to the UC1 and in turn relies on the UC1 Fan Prover safety circuit (P1 & P2) to allow its interlocked appliances to operate. Any pre/post-purge settings on the UC1 will be defaulted to the MAC1E. The MAC1E puts an end to difficult and costly job site wiring nightmares. Circuit board housed in oversized 18 gauge electrical box with multiple knock-outs for easy wiring connections. Model# MAC1E
Description Webb# Appliance Control 379227
part# 950-1020 950-1067 950-1030 950-1011
Description Webb# Motor Kit 192933 HST-J, HSJ, HSUL-J, HS115-5, HSI, HSU2-1, HST-1, HS115-1 Timer/Relay 1-10 Minute Adjustable 95506 HST-J, HST-1, HST-2, SS1, SS1C, SS1-R, SS2 Fan Prover With Sensing Tube Kit HS115-J, HSJ, HSUL-J, HST-J, HS1, HSUL-1, HST-1, HS115-1 152845 Wheel Kit 188537 HS1- HSUL-1, HST-1, HS115-1
Accessory Controls Parts part# 950-2080
Description Webb# Gas Pressure Switch 188540 WHKE, WHK-2
WHKE Millivolt Interlock Kit for Use with UC1 Control For use with the UC1 Universal Control, MAC1E or MAC4E auxiliary controls. The WHKE gas pressure switch actuates the Inducer/Venter through the A-B dry contacts on UC1, MAC1E or MAC4E. The Linear Limit switch disables the heater in the event of a venting malfunction. Includes JA1 thermocouple junction adapter. To interlock millivolt water heater(s) only with a UC1 controlled Inducer/Venter add a WHKE for each millivolt heater. To interlock a millivolt water heater and one 24/115 VAC furnace or boiler with a UC1 controlled Inducer/Venter, add a WHKE and a MAC1E. Model# WHKE
Description Webb# Interlock Kit 379224
Fresh Air In-Forcer™
F.W. Webb is the largest distributor of weil-mclain!
Features: • Affordably priced and installs fast. Plugs into electrical outlet. • Automatic clock/timer accommodates various air change requirements and lifestyles. • Warm incoming cold, fresh air by blending it with ambient room air before introducing it into home. • Damper closes during off cycles to prohibit cold air entry and warm air loss. Model# PAI-1T
222
Description Webb# Air In-Forcer 284421
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
223
15 venting
Model# UC1
Description Webb# SS1 Plenum Section (Includes UC1) 95505 SS1, SS1C, SS1-R, SS2 UC1 Control Circuit Board 256369 SS1 Fan Prover Kit 95507 SS1 High Limit Switch 95508 SS1 *Motor with Wheel 5/8” 95509 SS1 Wheel 5/8” Bore 95510 SS2 Prover (Old Style External J Box Mount) 215786
Z-Flex
SECTION
SECTION
15
15
Z-Vent™ Special Gas Vent Aluminum Chimney Liner Kits For Category I Gas Fired Heating Equipment and Gas Fireplaces Aluminum 2-ply Chimney Liner Kit
Mfr# desc. 3X25G 3” X 25’ 4X25G 4” X 25’ 5X25G 5” X 25’ 5.5X25G 5.6” X 25’ 6X25G 6” X 25’ 7X25G 7” X 25’ 3X30G 3” X 30’ 3X35G 3” X 35’ 4X35G 4” X 35’ 5X35G 5” X 35’ 5.5X35G 5.6” X 35’ 6X35G 6” X 35’ 7X35G 7” X 35’ 8X35G 8” X 35’
webb# 74603 74604 74605 215867 74606 74607 249152 74609 74610 74611 203389 74612 74613 74614
B-Vent Connector The V-Vent connector is designed to connect a Z-Flex aluminum chimney liner to a vent connector made of any brand of B-Vent. It is UL listed with our aluminum chimney liner kits and is easy to install. Mfr# desc. 4GC 4” 5GC 5” 6GC 6” 7GC 7” 8GC 8”
webb# 74634 74635 74636 74637 74639
B-Vent Gas Connector To attach two lengths of liner. Mfr# desc. 4BVC 4” 5BVC 5”
224
webb# 74637 74638
F.W. Webb Company
Mfr# desc. Z-Vent Pipe 2SVEPWCF0306 3” X 6” 2SVEPWCF0301 3” X 1’ 2SVEPWCF0301.5 3” X 18” 2SVEPWCF0302 3” X 2’ 2SVEPWCF0303 3” X 3’ 2SVEPWCF0304 3” X 4’ 2SVEPWCF0305 3” X 5’ 2SVEPWCF0308 3” X 8’ 2SVEPWCF0310 3” X 10’ 2SVEPWCF0406 4” X 6” 2SVEPWCF0401 4” X 1’ 2SVEPWCF0402 4” X 2’ 2SVEPWCF0403 4” X 3’ 2SVEPWCF0404 4” X 4’ 2SVEPWCF0405 4” X 5’ Elbows 2SVEEWCF0390 2SVEEWCF0490 2SVEEWCF0345 2SVEEWCF0445
3”, 90° 4”, 90° 3”, 45° 4”, 45°
webb# 95336 95335 192975 179232 95320 245595 95319 210883 192974 249174 206563 192979 224913 192976 204723
95323 95337 249176
Adjustable Wall Thimbles 2SVSWTF03 3” 2SVSWTF04 4”
95327 249175
Stainless Steel Chimney Liner Kit for Oil
Vent Terminations
Kit includes: Liner, deluxe rain cap, liner support, mortar collar, flashing.
Mfr# desc. Termination Coupling 2SVSTPF03 3” Z-Vent Rain Cap 2SVSRCF03
3”
webb# 151212 95328
Z-Vent Top Support/Storm Collar 2SVSLSF03 3”
95332
Z-Vent Adjustable Roof Flashing 2SVSADJF03 3”
95331
Z-Vent Fire Stop Spacer 2SVSFSF03 3”
95329
Z-Vent Fire Stop Support 2SVSFSSF03 3”
95330
Appliance Adapters Mfr# desc. Weil-McLain CGI Starter 2SVEWMFAF03 3”
95321 192973 95322 241497
Condensation Drains 2SVEVWCF03 3”, Vertical 2SVEDWCF03 3”, Horizontal 2SVEDWCF04 4”, Horizontal
Z-Vent™ Special Gas Vent (cont.)
webb#
4” X 3”
193335
Termination Tee 2SVSTTF03 2SVSTTF04
3” 4”
95324 222244
Termination Box 2SVSRTF03 2SVSRTF04
3” 4”
95338 222240
®
Weil-McLain GV (Series 2) Starter 2SVEMGVX03 3”
110578
Weil-McLain GV (Series 3) Starter 2SVEVSTF03 3”
206849
Stainless Steel Drip-Less Type A Connector 2CNNTRC06 6” 91875 2CNNTRC07 7” 91876 2CNNTRC08 8” 215480
Ametek Fan Connector 2SVSACAF03 3”
95341
Z-Vent Sealant 2SILRRTV106X
95333
3 oz. Tube
Utica Boiler Adapter 2SVSUBAF04 4”
249177
Buderus Starter 2SVB03
274892
Locking Bands 2SVSLBF03 2SVSLBF04
3” 4”
202539 192977
The F.W. Webb Heating Catalog
webb#
Used to mate Z-Flex liner to liner, T-Section or stovepipe.
Stainless Steel Stacking Tee with Cap and Removable Nose Spout 2ZRBTXX05 5” 193396 2ZRBTXX06 6” 194014 2ZRBTXX07 7” 201909 Note: Z-Flex tees are designed to be used with both flex and rigid lining systems. Use Type A Connector to attach Flex to Tee section. 3” and 10” nose spouts are not removable.
Stainless Steel Nose Cone Guides Mfr# desc. 4NC 4” 5NC 5” 6NC 6” 7NC 7” 3NC 8”
www.fwwebb.com
15
All Fuel Stainless Steel Z-Flex Mfr# desc.
95326
Condensation Drain Tube Kit 2SVEDTK Drain Tube Kit
webb# 163853 215823 74615 74616 74617 197991 74618 74619 74620 246751 201906 242086
165328
10” X 10”, width adjust from 5” to 10”
Reducers 2SVSR0403
Mfr# desc. 4X25O 4” X 25’ 5X25 5” X 25’ 6X25O 6” X 25’ 7X25O 7” X 25’ 8X25O 8” X 25’ 5X35O 5” X 35’ 6X35O 6” X 35’ 7X35O 7” X 35’ 8X35O 8” X 35’ 5X40O 5” X 40’ 6X40O 6” X 40’ 8X45O 8” X 45’
venting
Kit includes: • 2-ply aluminum liner. • Chimney flashing. • Rain cap. • Mortar collar. • 3 screws.
OEM specified and UL Listed Special Gas Vent for Category II, III and IV heating equipment. Z-Vent is approved as a replacement for high temperature plastic vent. • Simple gasketed connection – no sealant needed. • Features the highest pressure rating in the industry. • The only metallic special gas vent you can cut to length on site. • New fusion welded pipe seams for a smoother finish and better fit. • Compatible with all types of Z-Flex Z-Vent. • AL29-4C Stainless.
Z-Flex
webb# 74622 74623 74624 74625 74626
F.W. Webb Company
225
Chimney
SECTION
SECTION
15
15
Type B Gas Vent — Round Pipe Section size webb# 3” X 6” 306847 3” X 12” 306848 3” X 18” 306850 3” X 24” 306851 3” X 36” 306852 3” X 48” 306853 3” X 60” 306854 4” X 6” 306887 4” X 12” 306888 4” X 18” 306890 4” X 24” 306891 4” X 36” 306892 4” X 48” 306893 4” X 60” 306894 5” X 72” 306957 5” X 12” 306958 5” X 18” 306960 5” X 24” 306961 5” X 36” 306962 5” X 48” 306963 5” X 60” 306964 6” X 6” 307024 6” X 12” 307025 6” X 18” 307027 6” X 24” 307028 6” X 36” 307029 6” X 48” 307030 6” X 60” 307031
mfr# 7GV06 7GV12 7GV18 7GV24 7GV36 7GV48 7GV60 8GV12 8GV18 8GV24 8GV36 8GV48 8GV60
size webb# 7” X 6” 307087 7” X 12” 307088 7” X 18” 307090 7” X 24” 307091 7” X 36” 307092 7” X 48” 307093 7” X 60” 307094 8” X 12” 307116 8” X 18” 307118 8” X 24” 307119 8” X 36” 307120 8” X 48” 307121 8” X 60” 307122
45° Elbow — Sizes 3” to 30” Sizes 3” through 14” adjust easily from 0° to 45°. Sizes 16” through 30” are non-adjustable. mfr# 3GVL45 4GVL45 5GVL45 6GVL45 7GVL45 8GVL45
size 3” Adj. 4” Adj. 5” Adj. 6” Adj. 7” Adj. 8” Adj.
webb# 306866 306907 306977 307043 307103 307131
Type B Gas Vent — Round Adjustable Lengths
Adapters
Increasers
Sizes: 3” to 8”–12” lengths. Adjustable from 3” to 10” Adjustable lengths telescopes onto standard pipe sections for adjustments from 3” to 10” for 12” lengths.
Offers secure, listed connections between Type B Gas Vent and gas vents of other manufacturers. Available in 3”, 4”, 5”, and 6” diameters in male and female end models.
Used to increase vent size.
mfr# 3GV12A 4GV12A 5GV12A 6GV12A 7GV12A 8GV12A
Constructed of 4 sections for smoother bends and less resistance. Adjusts from 0° to 90° easily to clear rafters or ceiling joists. mfr# 3GVL90 4GVL90 5GVL90 6GVL90 7GVL90 8GVL90
F.W. Webb Company
size 3” Adj. 4” Adj. 5” Adj. 6” Adj. 7” Adj. 8” Adj.
webb# 306867 306908 306978 307044 307104 307132
mfr# 3GVWS 4GVWS 5GVWS 6GVWS 7GVWS 8GVWS
size 3” 4” 5” 6” 7” 8”
webb# 306880 306921 306990 307055 307112 307139
Tee Cap provides a closure for the branch of trunk of a tee.
Branch and trunk diameters are the same size. For small branch sizes, use a Reducing Tee up to 6” size. For larger sizes use increaser with standard tee. size 3” 4” 5” 6” 7” 8”
Provides 11/2” spacing.
Tee Cap
Standard Tee — Sizes 3” to 30”
mfr# 3GVT 4GVT 5GVT 6GVT 7GVT 8GVT
size webb# 4” Female 306896 4” Male 306897 5” Female 306966 5” Male 306967 6” Female 307033 6” Male 307034
Wall Strap
Adjustable 90° Elbow — Sizes 3” to 8”
webb# 306876 306916 306984 307049 307109 307136
mfr# 3GVTC 4GVTC 5GVTC 6GVTC 7GVTC 8GVTC
size 3” 4” 5” 6” 7” 8”
webb# 306877 306917 306985 307050 307110 307137
Draft Hood Connector Connects Type B Gas Vent directly to appliance draft hood. Flexible inlet can be shaped to fit oval draft hood outlets.
Increaser Tee — Sizes 4” to 6” Features branch with smaller diameter than trunk size. Convenient connection of furnace and water heater to a common vent. mfr# 4GVTR3 5GVTR3 5GVTR4 6GVTR3 6GVTR4
226
mfr# 4GVAF 4GVAM 5GVAF 5GVAM 6GVAF 6GVAM
size webb# 3” X 12” 306849 4” X 12” 306889 5” X 12” 306959 6” X 12” 307026 7” X 12” 307089 8” X 12” 307117
size webb# 54 X 3” 306918 5” X 3” 306986 5” X 4” 306987 6” X 3” 307051 6” X 4” 307052
mfr# 3GVC 4GVC 5GVC 6GVC 7GVC 8GVC
A 6” 6” 6” 6” 6” 6”
webb# 306857 306898 306968 307035 307097 307125
Pipe Collar Provides a cover for rough wall openings. Fits double wall pipe only. mfr# 3GVPC 4GVPC 5GVPC 6GVPC
www.fwwebb.com
size 3” 4” 5” 6” 7” 8”
size 3” 4” 5” 6”
webb# 306868 306909 306979 307045
The F.W. Webb Heating Catalog
mfr# 3GVX4 3GVX5 3GVX6 3GVX7 3GVX8 4GVX5 4GVX6 4GVX7 4GVX8
size webb# 3” X 4” 306882 3” X 5” 306883 3” X 6” 306884 3” X 7” 306885 3” X 8” 306886 4” X 5” 306923 4” X 6” 306924 4” X 7” 306925 4” X 8” 306926
mfr# 5GVX6 5GVX7 5GVX8 6GVX7 6GVX8
size webb# 5” X 6” 306992 5” X 7” 306993 5” X 8” 306994 6” X 7” 307057 6” X 8” 307058
Bucket Support Use the and hanger for starting a vent at ceiling level. Supports provide proper clearance and automatic positioning. Designed to fit between 16” O.C. Joists. Buckets only – available 9”– 22”. mfr# size 5GVRS6 5” - 6” 7GVRS8 7” - 8”
webb# 306981 307106
Bucket Support Hanger mfr# size 3GVRS4 3 - 4” 5GVRS6 5 - 6”
webb# 306873 306981
Firestop Support For supporting type B Gas Vent starting at appliance level. Serves as firestop, includes support bracket. Support bracket available separately (SB). mfr# 3GVRS 4GVRS 5GVRS 6GVRS 7GVRS 8GVRS
size 3” 4” 5” 6” 7” 8”
webb# 306872 306913 306980 307046 307105 307133
Wall Thimble Adjusts for various wall thicknesses from 4” to 6”. Provides proper clearance for vent from combustibles. mfr# 3GVWT 4GVWT 5GVWT 6GVWT 7GVWT 8GVWT
size 3” 4” 5” 6” 7” 8”
webb# 306881 306922 306991 307056 307113 307140
F.W. Webb Company
227
15 venting
mfr# 3GV06 3GV12 3GV18 3GV24 3GV36 3GV48 3GV60 4GV06 4GV12 4GV18 4GV24 4GV36 4GV48 4GV60 5GV06 5GV12 5GV18 5GV24 5GV36 5GV48 5GV60 6GV06 6GV12 6GV18 6GV24 6GV36 6GV48 6GV60
Chimney
SECTION
SECTION
15
15
Chimney Type B Gas Vent — Round
DuraCap
Temperature Engineered Chimney
Storm Collar
Installed on homes and business structures to protect against wind conditions that can cause waste gases Serves as a counter flashing. Use mastic to seal the vent pipe. to spill back into the structure through the appliance draft hood. mfr# size webb# 3GVSC 4GVSC 5GVSC 6GVSC 7GVSC 8GVSC
3” 4” 5” 6” 7” 8”
306874 306914 306982 307047 307107 307134
mfr# 3GVDC 4GVDC 5GVDC 6GVDC 7GVDC 8GVDC
size webb# 3” Standard 306859 4” Standard 306900 5” Standard 306970 6” Standard 307037 7” Standard 307099 8” Standard 307127
mfr# 4GVFSR 5GVFSR 6GVFSR 7GVFSR 8GVFSR
mfr# 3GVFF 4GVFF 5GVFF 6GVFF 7GVFF 8GVFF
Chimney Sections
size webb# 3” Tall Cone 306860 4” Tall Cone 306901 5” Tall Cone 306971 6” Tall Cone 307038 7” Tall Cone 307100 8” Tall Cone 307128
mfr# 9403GA 9404GA 9405GA 9406GA 9603GA 9604GA 9605GA 9606GA
size 6” X 12” 6” X 18” 6” X 24” 6” X 36” 8” X 12” 8” X 18” 8” X 24” 8” X 36”
webb# 307200 307202 307204 307206 307317 307319 307321 307323
mfr# 9403 9405 9407 9603 9605 9606
size webb# 6” X 12”, SS 307198 6” X 24”, SS 307203 6” X 36”, SS 307205 8” X 12”, SS 307315 8” X 24”, SS 307320 8” X 36”, SS 307322
size webb# 4” Steep Pitch 306903 5” Steep Pitch 306973 6” Steep Pitch 307040 7” Steep Pitch 307102 8” Steep Pitch 307130
mfr# 6HS-015 8HS-015 6HS-030 8HS-030 6HSS-030 8HSS-030
size webb# 6”, 15° 46034 8”, 15° 46070 6”, 30° 46035 6”, 30° 46071 6”, 30°, SS 256236 8”, 30°, SS 245838
mfr# 6HS-AIS 8HS-AIS
size 6” 8”
webb# 153638 46414
Cap Durable, all stainless steel constructed cap is designed to minimize downdraft. Features its own spark arrestor and bird debris screen. size 6” 8” 10”
webb# 46091 46139 46288
Firestop is required at each floor level, except at ceiling support or roof support. Provides correct spacing to combustible materials as the chimney passes through a combustible floor.
of
mfr# size 6HS-FSA 6” 8HS-FSA 8”
products. www.fwwebb.com
mfr# 6F 6FFU12 8F 8FFU 8FFU12
size webb# 6”, Standard 46039 6”, Standard 46040 8”, Standard 46075 8”, Med Pitch 256238 8”, Standard 46076
15
Tall Cone Flashing For flat to 1/12 pitch roofs. Use on flat roofs in snowpack areas to reduce chances of leakage.
Attic Insulation Shield
Firestop Assembly
exclusive distributor
F.W. Webb Company
Round Flashing Available in galvanized and aluminum models flat to 6/12 pitch (Standard) and for steeper pitches of 7/12 to 12/12 pitch, 13/12 to 18/12 pitch and 19/12 to 24/12 pitch.
mfr# 6HS-RCS 8HS-RCS 10FB-RC
F.w. webb is the
228
For use in pairs to permit chimney to “go around” joist, rafters or other projections. Add chimney sections between offsets to produce additional offset. Offsets are available with a stainless steel outer wall for corrosive environments.
Required shield for use in unoccupied attic areas to prevent insulation material from infringing on the 2 in. air space clearance. Stainless Steel
All Fuel Pipe
Flashings
Elbows
Temperature Engineered Chimney
Flashing – Standard Fits flat to 5/12 pitch roofs. Double seamed construction for protection from leakage. Standard flashing with 6” skirt (EFFU and RFFU). Flashing – Steep Pitch Fits 6/12 to 12/12 pitch roofs. Flashing – Tall Cone Fits flat to 1/12 roofs. use on flat roofs in snow-packed areas to reduce chances of leakage (12” riser). mfr# 3GVF 4GVF 5GVF 6GVF 7GVF 8GVF
webb# 306858 306899 306969 307036 307098 307126
Offsets
mfr# size webb# 6FT 6”, Tall Cone 46038 8FT 8”, Tall Cone 46074
Ceiling Support Assembly Use when chimney is installed in flat ceiling. 6” and 8” sizes fit between regular 16” O.C. ceiling joists. Cartoned to contain stainless steel flat black single wall adaptor. (For exposed-beam ceiling installations, use Roof Support Assembly). Flat black finish. mfr# size 6HS-CSA 6” 8HS-CSA 8”
webb# 46080 46128
Anchor Plate Use to support and connect chimney sections to a masonry firebox or an appliance which is specifically listed for direct connection to a plate and chimney system. mfr# 8HS-AP
size 8”
webb# 46134
webb# 46096 46144
Storm Collar Use with flashing to insure water-tight installation. mfr# 6SC 10SC
size 6” 10”
webb# 47072 46289
The F.W. Webb Heating Catalog
F.W. Webb Company
229
venting
Roof Flashings
size 3” 4” 5” 6” 7” 8”
Chimney
SECTION
15
Chimney Temperature Engineered Chimney Roof Support Assembly
Wall Thimble
For exposed-beam ceiling installations. Cartoned to contain stainless steel flat black single wall adaptor. (Use ceiling support assembly when chimney is to be installed in flat ceiling). Flat black finish.
Used with tee branch and chimney section to provide proper clearance to combustible materials. Flat black painted surface for interior wall eliminates need for trim plate.
mfr# size webb# 6HS-RSA12 6” X 11” L/Trim 46083 6HS-RSA24 6” 24” L/Trim 46084 8HS-RSA12 8” Round 46129 8HS-RSA24 8” 46131
mfr# size 6HS-WTP 6” 8HS-WTP 8”
webb# 46090 46138
Roof Brace Kit Use for tall chimneys or in windy areas to stabilize chimney above the roof. mfr# size 6HS-RBK 6” 8HS-RBK 8”
webb# 46100 46148
Chimney Tee Assembly – (HS-TA) Chimney tee, tee branch (made up of one 12” section of chimney), single wall adaptor, pipe and plate and tee cap. Use this combination where connection to chimney is made into branch of tee in “Through-the-Wall” installation.
Chimney Tee – (HS-T, HSS-T) Consists of chimney tee and tee cap in galvanized or stainless steel outer wall. mfr# 6HS-T 6HS-TA 6HSS-T 8HS-T 8HSS-T
size webb# 6” w/Cap 46036 6” w/Cap 153370 6” SS w/Cap 46037 8” w/Cap 46072 8” SS w/Cap 46073
Single Wall Adaptor Included in ceiling support assembly, roof support assembly and tee asembly for easier installation of single wall connector pipe. Stainless Steel. Flat black finish. mfr# 6SWA
size 6”
webb# 46101
Wall Support With Clean Out Supports chimney tee and chimney. Attach brackets to wall above or below heavy gauge base plate. Includes insulated tee cap. mfr# 6HS-WS 8HS-WS
230
size 6” 8”
Support Bracket Assembly Bracket for supporting chimney pipe offset, or for securing outdoor chimney to exterior wall while maintaining proper 2” clearance to wall. mfr# 6HS-SBA 8HS-SBA 10FB-FBA
size 6” 8” 10”
webb# 46099 46147 246982
Chimney Kits Round Kit
Through-the-Wall Kit
Round kit contains stainless steel cap, standard flashing, storm collar, ceiling support and single wall adpator.
Through-the-Wall Kit contains stainless steel cap, tee assembly, round flashing, round storm collar, wall support, painted wall thimble and three support bracket assemblies.
mfr# size 6HS-RKS 6” 8HS-RKS 8”
webb# 46008 46010
Adjustable Roof Support Assembly Designed for sloped or open-beam ceiling construction in retrofit installations. Adjusts from flat to 24/12 roof pitches. mfr# size 6PL-ARSA 6” 8PL-ARSA 8”
webb# 212894 163032
mfr# size 6HS-TWK 6” 8HS-TWK 8”
webb# 46010 72933
Open Beam Kit Open beam kit contains stainless steel cap, standard flashing, storm collar, roof support and single wall adaptor. mfr# size 6HS-RKRS 6”
webb# 213143
webb# 46088 152873
F.W. Webb Company
www.fwwebb.com
SECTION
16
16 technical information
Technical Information Troubleshooting . . . . . . . . . . . . . . . . . . 232-256 Technical Tips . . . . . . . . . . . . . . . . . . . 257-281 Cross Reference . . . . . . . . . . . . . . . . . . 282-295
The F.W. Webb Heating Catalog
16_Troubleshooting_p295.indd 231
F.W. Webb Company
231 3/24/08 4:29:56 PM
Troubleshooting SV950/SV9502 SmartValve™
SECTION
SECTION
16
16
INSET A
CHECK FOR PROPER VOLTAGE AT CONTROL HARNESS (SEE INSET A). VOLTAGE SHOULD BE 24V BETWEEN THERMOSTAT OR PRESSURE SWITCH AND 24V COMMON, AND 24V 2 BETWEEN 24V COMMON AND 24V HOT.
NOTE: BEFORE TROUBLESHOOTING, BECOME FAMILIAR WITH THE STARTUP AND CHECKOUT PROCEDURE. ALSO CHECK PILOT BURNER ELEMENT FOR RESISTANCE LESS THAN 10 OHMS WITH ELEMENT AT ROOM TEMPERATURE.
NO
YES
PLUG HARNESS INTO SmartValve CONTROL. WAIT FOR INTERNAL CHECK DELAY
YES
NO
EFT OUTPUT 24 VOLT COMMON
24 VOLT HOT
CHECK FOR DAMAGED OR MISSING TERMINALS IN CONNECTOR
CHECK: • LINE VOLTAGE POWER • LOW VOLTAGE TRANSFORMER • LIMIT CONTROLLER • THERMOSTAT • WIRING • AIR PROVING SWITCH ON COMBUSTION AIR BLOWER SYSTEM • VENT DAMPER (IF USED) IS OPEN AND END SWITCH MAKES WITH PILOT BURNER CABLE CONNECTED, MEASURE VOLTAGE AT SmartValve HSI ELEMENT 1 2 OUTPUT (SEE INSET B) 24V NOMINAL.
END VIEW OF CONTROL HARNESS CONNECTOR
HSI TERMINALS
PLUG HARNESS INTO SmartValve CONTROL. WAIT FOR INTERNAL CHECK DELAY (SV9501) OR PREPURGE (SV9502)
REPLACE SmartValve CONTROL
NO
IGNITER WARMS UP AND GLOWS RED
REPLACE IGNITER/FLAME ROD ASSEMBLY NO
• TURN ON GAS SUPPLY • PILOT BURNER LIGHTS
CHECK THAT PILOT GAS IS FLOWING. WAIT TO ASSURE PILOT GAS TUBING IS PURGED.
YES
YES
MEASURE VOLTAGE BETWEEN 24V HOT AND 24V COMMON LEADS TO SmartValve CONTROL. MUST 2 MEASURE AT LEAST 19.5 VAC WITH IGNITER POWERED. SEE INSET A TO IDENTIFY PROPER LEAD. THIS CHECK MUST BE DONE WITH THE SmartValve CONTROL CONNECTED AND IGNITER POWERED.
NO
YES
NO
YES
NO
NO
WITH PILOT BURNER CABLE CONNECTED, MEASURE VOLTAGE AT SmartValve HSI ELEMENT 1 2 OUTPUT (SEE INSET B) 24V NOMINAL.
END VIEW OF CONTROL HARNESS CONNECTOR
EFT OUTPUT 24 VOLT COMMON
24 VOLT HOT
CHECK FOR DAMAGED OR MISSING TERMINALS IN CONNECTOR
CHECK: • LINE VOLTAGE POWER • LOW VOLTAGE TRANSFORMER • LIMIT CONTROLLER • THERMOSTAT • WIRING • AIR PROVING SWITCH ON COMBUSTION AIR BLOWER SYSTEM • VENT DAMPER (IF USED) IS OPEN AND END SWITCH MAKES
INSET B HSI TERMINALS
16
NO
REPLACE SmartValve CONTROL
YES
1
REPLACE IGNITER/FLAME ROD ASSEMBLY
REPLACE SmartValve CONTROL NO
• TURN ON GAS SUPPLY • PILOT BURNER LIGHTS
CHECK TRANSFORMER AND LINE VOLT SUPPLY
24 VOLT THERMOSTAT OR PRESSURE SWITCH
NOTE: BEFORE TROUBLESHOOTING, BECOME FAMILIAR WITH THE STARTUP AND CHECKOUT PROCEDURE. ALSO CHECK PILOT BURNER ELEMENT FOR RESISTANCE LESS THAN 10 OHMS WITH ELEMENT AT ROOM TEMPERATURE.
START • TURN OFF GAS SUPPLY • ASSURE SmartValve SWITCH IS IN ON POSITION • DISCONNECT SYSTEM CONTROL HARNESS • SET THERMOSTAT TO CALL FOR HEAT CHECK FOR PROPER VOLTAGE AT CONTROL HARNESS (SEE INSET A). VOLTAGE SHOULD BE 24V BETWEEN THERMOSTAT OR PRESSURE SWITCH AND 24V COMMON, AND 24V 2 BETWEEN 24V COMMON AND 24V HOT.
INSET B
YES
1
INSET A
technical information
IGNITER WARMS UP AND GLOWS RED
24 VOLT THERMOSTAT OR PRESSURE SWITCH
troubleshooting
SV9501/SV9502 SmartValve™ TROUBLESHOOTING SEQUENCE
SV9500 SmartValve™ TROUBLESHOOTING SEQUENCE
START • TURN OFF GAS SUPPLY • ASSURE SmartValve SWITCH IS IN ON POSITION • DISCONNECT SYSTEM CONTROL HARNESS • SET THERMOSTAT TO CALL FOR HEAT
Troubleshooting SV950/SV9502 SmartValve™
YES
NO
CHECK THAT PILOT GAS IS FLOWING. WAIT TO ASSURE PILOT GAS TUBING IS PURGED. RECYCLE CALL FOR HEAT IF NECESSARY.
REPLACE SmartValve CONTROL
YES
MEASURE VOLTAGE BETWEEN 24V HOT AND 24V COMMON LEADS TO SmartValve CONTROL. MUST 2 MEASURE AT LEAST 19.5 VAC WITH IGNITER POWERED. SEE INSET A TO IDENTIFY PROPER LEAD. THIS CHECK MUST BE DONE WITH THE SmartValve CONTROL CONNECTED AND IGNITER POWERED.
YES
REPLACE IGNITER/FLAME ROD ASSEMBLY
NO
CHECK TRANSFORMER AND LINE VOLT SUPPLY
YES
REPLACE IGNITER/FLAME ROD ASSEMBLY
• CHECK THAT PILOT FLAME MAKES GOOD CONTACT WITH PILOT BURNER FLAME ROD. • CHECK FOR GOOD ELECTRICAL CONNECTION THROUGH THE PILOT TUBING. • IF BOTH OF THE ABOVE ARE GOOD, REPLACE IGNITER/FLAME ROD ASSEMBLY
MAIN VALVE OPENS AND MAIN BURNER LIGHTS YES
NO
MAIN VALVE OPENS AND MAIN BURNER LIGHTS YES
CYCLE THERMOSTAT OFF AND BACK ON NO
SYSTEM IS OKAY
1
MAIN BURNER LIGHTS
IGNITER WILL STAY ENERGIZED AS LONG AS APPLIANCE CALL FOR HEAT IS IN PLACE.
2
WHEN MEASURING VOLTAGE AT CONNECTIONS, USE CARE TO ASSURE TERMINALS ARE NOT DAMAGED.
CYCLE THERMOSTAT OFF AND BACK ON
REPLACE SmartValve CONTROL
M17146
SYSTEM IS OKAY
1
232 16_Troubleshooting_p295.indd 232-233
F.W. Webb Company
• CHECK THAT PILOT FLAME MAKES GOOD CONTACT WITH PILOT BURNER FLAME ROD. • CHECK FOR GOOD ELECTRICAL CONNECTION THROUGH THE PILOT TUBING. • IF BOTH OF THE ABOVE ARE GOOD, REPLACE IGNITER/FLAME ROD ASSEMBLY
www.fwwebb.com
NO
MAIN BURNER LIGHTS
IGNITER WILL CYCLE OFF AND BACK ON ONCE DURING THE 90 SECOND IGNITION TRIAL. ALL VOLTAGE MEASUREMENTS MUST BE TAKEN WHILE THE IGNITER IS POWERED.
The F.W. Webb Heating Catalog
2
REPLACE SmartValve CONTROL
WHEN MEASURING VOLTAGE AT CONNECTIONS, USE CARE TO ASSURE TERMINALS ARE NOT DAMAGED. M17143
F.W. Webb Company
233 3/24/08 4:29:57 PM
Electrical System Troubleshooting YES
NO
If it is determined that problem is not fuel related but instead is electrical in nature, follow the boxes until the problem is solved. Then run the unit or a cycle to be sure problem does not repeat.
SECTION
16
16
• Remove primary control cover. • Jump the thermostat T-T terminal on the primary control if not done. • Reset safety switch.
CAUTION Be sure fire chamber is free of any unburned fuel.
Electrical System Troubleshooting troubleshooting
Does burner start?
Electrical Troubleshooting
SECTION
caution
• If the relay contacts pull in but are “chattering”, relay is bad and control needs to be replaced. • If relay contacts pull in and burner runs but still shuts off on safety, replace CAD CELL eye. • If burner starts but stops shortly after (short cycles) without tripping safety switch, check for loose wire and replace primary control.
YES
to test primary control safety shutdown • After burner starts, disconnect one wirelead from the cad cell at the primary F-F terminal. Primary control should shut down on safety after 15 to 45 seconds.
If any problem repeats itself, start over.
Does burner continue to run?
16
Does transformer have good spark? NO
• Check wire contacts. If good, and system has primary control, replace transformer.
YES
YES
Primary Control • Remove the primary control from the burner housing and check if voltage is being supplied to the control at the black and white wires, use a meter. Voltage should be 120 volts. • Do not make contact with transformer springs.
Is 120 volts present? NO
• Reset safety switch. • Check the same white lead with orange lead for power to motor and transformer.
Is 120 volts present?
technical information
Always turn off electrical power when removing or replacing controls and be alert and careful when troubleshooting controls with power on.
• If 120 volts is present and the transformer has a good spark but the motor doesn’t start, the problem can be either the motor or pump. Carefully turn motor fan. If it rotates easily, motor needs to be replaced. If hard to spin, turn power off and remove motor. With motor off the burner, try again. If it doesn’t run, replace motor.
NO
Find and repair open circuit.
Find and repair open circuit.
234 16_Troubleshooting_p295.indd 234-235
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
235 3/24/08 4:29:57 PM
Troubleshooting Fuel System
SECTION
SECTION
16
16
Troubleshooting Fuel System
Is oil flow steady and without air bubbles or foam?
YES
• Remove nozzle assembly; check gap between electrode rods; adjust as necessary. • Check electrode rods–they should be clean with no carbon build up–and check porcelain insulator for cracks; clean and remove any carbon build up. • Reassemble nozzle assembly onto nozzle supply line and direct spray into a container.
• Does oil supply tank have enough oil in it? If not, fill with at least 10 gallons of fuel if tank is 275 gallons. • Are all oil supply line valves open? • Are all oil supply line fittings tight, not to allow air leakage?
Is blast tube free of any obstruction?
A
YES
• Run for a cycle to be sure flame doesn’t cut out.
YES
If any problem repeats itself, start over.
Does unit continue to run without shutting off on safety?
NO
NO
Clean out using a brush.
16
NO
• If noisy, open inspection door. • Nozzle may be too large or unit may need to be vacuumed out.
• Clean or replace CAD CELL eye.
Does unit continue to run without shutting off on safety?
Replace nozzle.
YES
NO YES
Go to Box A.
Is oil flow steady and without air bubbles or foam? YES
Close valve before filter. Place a container under oil filter. Remove can. Remove and check oil filter element.
Is canister full of oil?
See Electrical Troubleshooting.
YES
Remove pump cover. Is pump strainer clean?
NO
NO
With can off and a container under filter assembly, open valve.
Is oil filter element clean?
Does oil flow?
NO
Replace oil filter and gasket. The pump stainer may need to be cleaned or replaced as well.
• Reassemble nozzle line. • Restart burner.
Is flame uniform and relatively quiet?
NO
NO
• • • •
YES
technical information
Is oil flow steady and without air bubbles or foam?
NO
• Check blast tube for any obstructions or carbon build-up on end cone.
Is spray a fine mist with no restriction or dripping?
Repair as needed.
Place a container under pump bleeder and bleed pump.
troubleshooting
Always turn off electrical power when removing or replacing controls and be alert and careful when troubleshooting controls with power on.
YES
• Clean or replace. • Nozzle may also need to be replaced.
YES
• Check coupling between pump and motor.
Is it turning? NO
• Remove motor from burner housing. • Turn pump shaft by hand.
YES
• Check tube for any obstructions or carbon build-up on end cone.
YES
Replace pump. Go back to Box A.
Is blast tube free of any obstruction? NO
Replace coupling.
Does shaft turn freely in direction of arrow on pump cover?
NO YES
• Oil line must be restricted or clogged. • Use a pressure vacuum pump to remove blockage in the oil lines until oil flows unrestricted.
NO
Clean out using a brush.
Go to Box A.
236 16_Troubleshooting_p295.indd 236-237
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
237 3/24/08 4:29:58 PM
Troubleshooting Fuel System
SECTION
SECTION
16
16
If this circumstance occurs, all unburned fuel must be removed and all surfaces wiped clean of fuel all the way to and including the chimney base.
Is safety lockout switch out?
YES
NO
YES
NO YES
Is motor overload switch tripped? Reset.
YES
Does burner start? NO
See Electrical Troubleshooting.
Does burner start? NO
Run unit for a full cycle to be sure problem doesn’t repeat.
• Start checking for voltage at the first control that power is being supplied to on the boiler. • Check all ground wire connections. • Check all electrical contact, wire nuts, and screw terminals. • See Electrical troubleshooting Primary control.
Is oil flow steady and without air bubbles or foam? NO
See Fuel Troubleshooting chart.
YES
• Use an insulated screwdriver to check transformer for spark. Start at either spring and gradually work to halfway point. Spark should be white to blue and should be able to reach half way between springs. Check both directions. • Transformer springs must make full contact with electrode rods. NO
See Electrical Troubleshooting.
238 16_Troubleshooting_p295.indd 238-239
F.W. Webb Company
YES
• Reassemble nozzle line and put transformer back in place. • Reset safety switch.
Is flame steady and does burner continue to run for a cycle without shutting down on safety? NO
• If flame is good but burner shuts off on safety, see Electrical Troubleshooting. • If flame isn’t steady, see Fuel Troubleshooting.
www.fwwebb.com
1. Dirty boiler water in the system. 2. Low water pressure. 3. Bad control or thermostat wiring. 4. Zone valve. 5. The heating supply or radiator being air-bound. 6. A frozen zone. 7. Too small of a nozzle being used. 8. The circulator coupling. Before starting to look for the problem, make sure the thermostats are calling for heat. You may be able to hear the problem at the boiler. A broken circulator coupling inside the housing is an easy fix: turn off the power to the boiler and replace the coupling. Make sure the circulator shaft can turn easily, you may need to oil it or replace the entire circulator. If there’s no noise, check the boiler water pressure gauge there should be at least 15 p.s.i. Add water from the boiler feed valve as needed. Check the supply and return pipes to feel if they’re hot. If the supply and the return aren’t hot, check the boiler temperature gauge. If the temperature is low, check the high limit setting on the aquastat - it should be between 160 to 180 degrees for the winter. The low setting on the aquastat should be at least 20 degrees lower than the high setting. If the supply is hot but the return isn’t, re-check the circulator; be sure that power is being supplied to it. If it is not, check the wiring contacts: if good, check for an open circuit. Power should be being sent to the aquastat or primary control. If there is no power, replace the unit that is bad. If power is being supplied, check to see if the circulator is turning. On a one piece circulator that has the motor bolted directly to the circulating pump housing you should be able to teil if it’s vibrating, if the unit is turning. If the unit is not turning, first try and unfreeze it by turning the motor. If the circulator that isn’t working has a motor attached to the pump housing and uses a coupling to connect them, turn the power off to the boiler. Depending on what type of coupling is used unbolt the motor and coupling and remove them. With the motor removed, check the pump shaft in the housing to make sure it rotates easily: if not, oil or replace the whole assembly. If the circulator is a one piece unit, having the motor attached right to the housing with no coupling, then replacing it is more involved. With the power off, close the valve above the circulator and the one before the feed valve: if there is no valve, or it is not working, close the main water supply valve. With this done, drain the boiler until the boiler gauge reads “0” psi. Disconnect the electrical wiring to the circulator and remove the four bolts which attach it. The replacement circulator should fit right into place. No matter which you do, always replace all gaskets with new ones. If the circulator is working and the system has a zone
The F.W. Webb Heating Catalog
If all else is working the system may be air-bound and you will have to bleed the system. When you feel the return pipe getting hot, and if you see air bubbles leaving the system with the water flow, you know that the system was airbound. You may also need to bleed the radiators. If the return line isn’t coming back hot or isn’t coming back at all, the line might be frozen. The best way to keep pipes from freezing is to insulate them with either foam fitting sleeves or fiberglass wrapping. Electric wrap heating tape works well and is not expensive if used only during the cold season. If everything else is working properly but the supply and the return are just warm and not hot, and if the boiler temperature gauge is showing no more than 160 degrees, the nozzle might have been incorrectly sized. Check the boiler information label for the correct size. If back pressure exists you’ll have to vacuum the boiler. If the nozzle is correct and the previous problem still exists, then the boiler water may be dirty. Dirty water will not rise high enough tin temperature on cold days and will need to be flushed. Replace with clean water and bleed the system of air. First step in troubleshooting the pressure relief valve is to check the boiler pressure gauge reading: if it is 25 p.s.i. or more, proceed with the troubleshooting. Check to see what type of water expansion unit the system is using. If an expansion tank is being used, it is most likely the cause and needs to be drained. When replacing any valve or component that is in the heating system piping and under pressure, turn off power to the boiler, turn water supply off, and drain the boiler of all pressure. A closed system will create a vacuum, you can open the pressure relief valve, which will break the vacuum and drain out the water. When finished, bleed the system of air. Where an Extrol tank is used on the system, it may have become water logged. An easy test to determine this is placing one hand at the top of the tank and the other at the bottom: you should feel a difference in temperature, with one side being hot from the boiler water, the other side remaining cool. If no difference in temperature can be felt, the tank is water logged and needs to be replaced. If a difference in temperature does exist, the Extrol tank is functioning properly. System pressure should return to 15 p.s.i.: if it does not, try draining the boiler drain valve of a small amount of water to drop the pressure gauge reading to 15 p.s.i. This should solve the problem, but it id important to remember when you are finished to listen for the sound of water being added to the boiler and to check the boiler gauge again.
F.W. Webb Company
16 technical information
• Check to be sure electrical power is being supplied to unit (all electrical switches, fuses and circuit breakers are on). • If EMERGENCY switch is off restore power. • Check motor overload switch. • Make sure unit is calling for heat by turning up thermostat. A line voltage thermostat acts as a switch and must make contact to close the circuit.
• Disconnect nozzle line and position it into a container. • Tighten the nut on pump side of line before restarting burner. • Reset safety switch.
valve, check it. If it is not working you can manually open it like a flow-check valve for a temporary fix.
troubleshooting
There can be additional reasons for not having heat. They can include:
MAKE SURE FIRE CHAMBER IS FREE OF ANY UNBURNED FUEL
This is a very dangerous condition and needs immediate attention to correct it. If the primary control does not shut the system down on safety, unburned fuel may continue to be sprayed into the fire chamber.
No Heat with Burner Running
239 3/24/08 4:29:58 PM
No Heat with Burner Running
SECTION
SECTION
16
16
Testing Combination Controls troubleshooting
No sound should be evident, if you hear this, close the valve located right before the feed valve: this will stop the water from entering, the feed valve is not operating correctly and needs to be replaced. There are two types of boiler feed valves: both are “fast-fill”, one, called a dual valve, also functions in combination as a pressure relief valve. If the system is currently using a dual valve, you can either replace it with another valve or add a pressure relief valve into the system along with a feed valve. When installing the new valve, use a piping compound and Teflon tape on all but the first two threads of the valve. Also check whether or not town or local codes require a backflow preventer. If the valve is operating correctly and no water is entering from this point, and you can hear the water running and the boiler continues to release water out the pressure relief valve, an increase in pressure on the gauge, the domestic hot water coil may have a small hole in it. To test for this, close the water supply to the coil and listen to see if it stops the water from entering the boiler.
Westwood Technical information for the service professional
TESTING COMBINATION CONTROLS STOP! READ THIS ADVISORY NOW! These procedures are for use by professional service technicians to test safety controls. They are for professional use only by qualified persons familiar with oil heating systems, equipped with the proper tools and test equipment, familiar with all governing codes and ordinances, and licensed by the proper authority where applicable.
If the water stops flowing, the coil needs to be replaced. If the boiler pressure gauge shows 15 to 25 p.s.i. and the pressure relief valve is still discharging water or dripping, the valve is not seated properly and needs to be replaced. Clean off and lift the lever momentarily to relieve pressure and to reseat the valve. If dripping still continues, the valve needs to be replaced. When installing the new valve, use piping compound and Teflon tape on all but the first two threads of the valve: to ensure that no foreign matter enters the valve body.
16
Bleeding the System of Air 1. Turn power off. 2. Attach a hose to purge valve. 3. Close the shut off valve. 4. Open the purge valve while adding water into the system from the feed valve. 5. After air is removed from the system, close the purge valve and stop adding water. 6. Reopen the shut off valve. 7. Check water pressure (15 to 20 psi.) If more than one zone, continue the same steps for all zones. When the boiler is back on, as the cold water is heated it may bring the boiler water pressure higher than 20 psi. Open the boiler drain valve to bring the pressure back down to 15 to 20 psi, or the pressure relief valve will open to discharge the higher pressure.
technical information
I M P O R TA N T • Boiler temperature must be at least 150° to use these procedures. • Tests must be performed exactly as written in the order listed. • The control must pass all tests to be considered good. • If control passes, reconnect wiring and adjust temperature and differential settings. Whenever the voltmeter icon appears in a test, measure the voltage between terminal 2 and each test terminal. If results match exactly, proceed to the next test. If results differ, stop and condemn control. The light bulb symbol means the terminal should be energized. PROCEDURE FOR TESTING:
HONEYWELL L8024A & L8124A BEFORE TESTING THE CONTROL:
Bleeding the System of Air with Zone Valves 1. Turn power off. 2. Attach a hose to purge valve. 3. Close the shut off valve. 4. Open the purge valve while adding water into the system from the feed valve. 5. After air is removed from the system, close the purge valve and stop adding water. 6. Reopen the shut off valve. 7. Check water pressure (15 to 20 psi.) If more than one zone, continue the same steps for all zones. When the boiler is back on, as the cold water is heated it may bring the boiler water pressure higher than 20 psi. Open the boiler drain valve to bring the pressure back down to 15 to 20 psi, or the pressure relief valve will open to discharge the higher pressure.
1. 2. 3. 4. 5.
With power on, check that there is power between terminals 1 and 2. Turn off power. Use a meter to verify power is off. Disconnect low voltage wires from T-T terminals. Disconnect line voltage wire on B1 terminal. Set high limit above water temperature. Set low limit below water temperature. Set the differential at 10°.
TEST TERMINALS
TEST NO.
B1 C1 ZC ZR
DO THE FOLLOWING:
1
Turn on power
2
Jump T-T terminals
3
Set High Limit below water temperature
4
Set Low Limit above water temperature
5
Remove T-T Jumper
Not for sale. Provided free to the trade. Copies available through your local wholesale supplyhouse.
240 16_Troubleshooting_p295.indd 240-241
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
241 3/24/08 4:30:00 PM
Testing Combination Controls
SECTION
SECTION
16
16 L7224 Series Oil Electronic Aquastat® Controller
HONEYWELL R8182A, H* and W-R 6C93 BEFORE TESTING THE CONTROL: 1. 2. 3. 4. 5.
With power on, check that there is power between terminals 1 and 2. Turn off power. Use a meter to verify power is off. Reset safety switch. Disconnect low voltage wires from T-T and F-F terminals. Disconnect line voltage wire on B1 terminal. Set high limit above water temperature. Set low limit below water temperature. Set the differential at 10°.
TEST TERMINALS
TEST NO.
DO THE FOLLOWING: Turn on power
2
Attach flame simulator to F-F terminals. Jump T-T terminals
3
Disconnect flame simulator from either F teminal. When relay pulls-in, start timing safety.
4
After relay locks out on safety.
5
Reset safety. When relay pulls-in, reattach flame simulator to F terminal. (Relay should continue to run and not lock out)
6
Set High Limit below water temperature
7
Set Low Limit above water temperature
8
Remove T-T Jumper
To discourage unauthorized changing of Aquastat® settings, a procedure to enter the adjustment mode is required. To enter the adjustment mode, press the UP, DOWN, and I buttons simultaneously for three seconds. Press the I button until the feature requiring adjustment is displayed: • HL—High Limit. • LL—Low Limit. • Ldf—Low Limit differential. • F - C—°F or °C. Then press the UP and/or DOWN buttons to move the set point to the desired value. After 60 seconds without any button inputs, the control will automatically return to the READ mode.
UNDERSTANDING HONEYWELL DIFFERENTIALS Low Limit/Reverse Differential On Temp Rise — Adjustable On Temp Fall — 10° Non-Adjustable
EXAMPLE: High Limit set at 180° Burner off = 180° Burner on = 170°
EXAMPLE: Low Limit set at 160° Differential set at 20° Burner off (circ. on) = 170° Burner on (circ. off) = 150°
W
P
16_Troubleshooting_p295.indd 242-243
F.W. Webb Company
To use the L7224U in a cold start boiler application, disable the Low Limit function by pressing the UP arrow button, DOWN arrow button and I buttons simultaneously for three seconds. Then push the I button until LL is displayed. Then press the down arrow button until OFF is displayed.
Text
Description
bt HL LL Hdf Ldf tt tte brn cir Zc Zr err f c
Boiler Temperature High Limit Low Limit High Limit Differential Low Limit Differential Local Thermostat Status Enviracom Thermostat Status Burner Status Circulator Status Zone Control Zone Request Error Code Degrees Fahrenheit Degrees Celsius
Display Shows
16
Table 1. LED Error Codes error code
cause/action
Err1
Sensor fault; check sensor.
Err2
ECOM fault; check EnviraCOM. wiring.
Err3
Hardware fault; replace control.
Err4
B1 fault; check B1 wiring/voltage.
Err5
Low Line; Check L1-L2, 110 Vac.
Err6
Fuse; Check ECOM wires, Replace fuse.
Err7
EEPROM, HL, LL, Hdf, Ldf, Reset to default values.
Err8
Repeated B1 fault (voltage present at B1 when output is turned off); check B1 wiring/voltage.
Display
In the RUN mode, the Aquastat® will flash “bt” (boiler temp) followed by the temperature (i.e., 220), followed by °F or °C.
Westwood Products Inc. South River, NJ 08882
Not for sale. Provided free to the trade. Copies available through your local wholesale supplyhouse.
242
On the L7224U the High Limit, High Limit Differential, Low Limit, and Low Limit Differential can be adjusted to the settings recommended by the boiler OEM.
Adjusting Settings
* The R8182H has no B1 terminal. Instead it uses a wire (usually orange) to connect to the burner. Instead of F-F terminals, it uses two wires, (usually blue or yellow) to connect to the flame detector leads. Adjust the procedure accordingly for this control.
High Limit Differential On Temp Rise — 10° Non-Adjustable On Temp Fall — 10° Non-Adjustable
The following service procedure provides a quick overview for L7224 Series Controllers. For more information, refer to form 69-1384.
technical information
1
B1 C1 ZC ZR
TECHNICIAN’S QUICK REFERENCE GUIDE
Pressing the I button again will display the LL (Low Limit) followed by a three-digit number and the corresponding degree designator. See the table below for an explanation of display readout. After approximately 60 seconds without any key presses, the display will enter a dim display mode. To return to the bright display mode, simply press and release any key.
troubleshooting
PROCEDURE FOR TESTING:
Testing Combination Controls
www.fwwebb.com
To read boiler settings, press the I key to read the parameter of interest. For example, press I (HL) High Limit is displayed, followed by a three-digit number, i.e., 220, followed by ºF or ºC.
The F.W. Webb Heating Catalog
F.W. Webb Company
243 3/24/08 4:30:01 PM
SECTION
16
Testing Combination Controls Action
System response
Thermostat calls for heat.
Circulator starts when water temperature is above Low Limit setting (if applicable). Boiler temperature is checked. Burner starts when water temperature is below High Limit setting.
Boiler exceeds the High Limit.
Burner is turned off. Burner restarts when the water temperature drops below the High Limit setting minus the differential.
Thermostat is satisfied.
Circulator and burner turn off.
Error conditions 1-5.
If an error condition is detected, all outputs except ZC are shut down. Burner is off. Control continues to function and restarts when error is corrected. During the error check sequence, the system checks for drift in the sensor and corrosion in the connections. If error condition 6 or 7 occurs, the control has reset the High Limit, Low Limit and Differential Setting to a default setting and will continue to run at those settings. Performance of the system will be degraded.
Error condition 8.
If the error condition is detected, all outputs except ZC are shut down. Burner is off. Control continues to function and restarts when all three user keys have been pressed longer than 60 seconds.
System condition Boiler is cold, house is cold
check
action
Display is ON; TT-LED is ON B1 LED is ON
120 Vac at B1B2
• If no, replace control. • If yes, check burner and wiring.
Display is ON; TT-LED is ON
Refer to err on display
Installation and Wiring • HeatManager mounts directly to Aquastat™ or electric junction box.
— • 120 Vac at C1-C2, check wiring to pump. • Wiring ok, is pump running? If not, replace the pump. • If pump is running, check for trapped air or closed zone valves.
Boiler is hot, house is cold
Troubleshooting
When attempting to diagnose system performance, reference the LED display to help identify specific areas not working properly. The LED display will scroll “err”, followed by a digit (1-8). See Table 1 for a description of the error and suggested actions. See below for a troubleshooting guide.
diagnostic condition
HeatManager Installation & Wiring
Display is ON; TT-LED is ON C1 LED is ON
120 Vac at C1-C2
Display is ON; TT-LED is ON C1 LED is OFF; ZC LED is ONb
Boiler below the Low Limit temperature, wait for boiler to go above Low Limit temperature.
Display is ON; TT-LED is ON ZC LED is OFFc
Boiler above LL? If yes, check for 120 Vac between ZC and L2
16 technical information
Error conditions 6-7.
Table 3. Troubleshooting Guidea
16 HeatManager
troubleshooting
Table 2. L7224 Controller Operating Sequence
SECTION
• If no 120 Vac, replace control. • If yes, check zone relays, circulators and wiring.
. Refer to Fig. 5 for Display and LED locations. . ZC LED ON indicates ZC terminal power is OFF. c . ZC LED OFF indicates ZC terminal power is ON. a b
Table 3. Troubleshooting Guidea System condition
Boiler is cold, house is cold
diagnostic condition
check
action
Display is OFF
120 Vac system power.
Turn system power on.
Display is ON; TT-LED is OFF
24 Vac T-T
No 24V; replace control
Display is ON; TT-LED is OFF
24V present; disconnect thermostat, short T-T
Boiler starts, check wiring and thermostat
• Complete installation instructions and wiring diagram are supplied with product.
Typical 115/230V Power & Control — Boiler Burner Circuit
. Refer to Fig. 5 for Display and LED locations. b . ZC LED ON indicates ZC terminal power is OFF. c . ZC LED OFF indicates ZC terminal power is ON. a
• Complete installation instructions and wiring diagram are supplied with product.
244 16_Troubleshooting_p295.indd 244-245
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
245 3/24/08 4:30:02 PM
Boiler Controls: Dual Aquastat Multizone
16
16
T T
F F
Boiler Controls: Single High-Limit Aquastat POWER SUPPLY CIRCUIT BREAKER
SINGLE AQUASTAT CONTROL
LINE VOLTAGE THERMOSTAT
L2(NEUTRAL)
SERVICE OR EMERGENCY SWITCH
L1 (HOT)
CIRCULATOR
L2 (NEUTRAL)
IGNITION TRANSFORMER
SERVICE OR EMERGENCY SWITCH
POWER IN
B
W
CIRCULATOR ZONE 1
B
B
EMERGENCY SWITCH
R
2 WIRE
W
IGNITION TRANSFORMER
LINE VOLTAGE THERMOSTAT
POWER IN
W
BURNER MOTOR
B
W
W
B
BURNER MOTOR
LINE VOLTAGE THERMOSTAT
LINE VOLTAGE THERMOSTAT
16 technical information
CIRCULATOR ZONE 2
W
PRIMARY CONTROL
L1(HOT)
LINE VOLTAGE THERMOSTAT ZONE 2
B
troubleshooting
POWER SUPPLY CIRCUIT BREAKER
SECTION
PRIMARY CONTROL
DUAL AQUASTAT CONTROL
LINE VOLTAGE THERMOSTAT ZONE 1
SECTION
W W
EMERGENCY SWITCH
B
B
3 WIRE
2 WIRE
2 WIRE B
R
B
B
W R
W
W B
HIGH
R
3 WIRE W
W
2 WIRE
JUNCTION BOX (1800 BOX)
W
B
B
JUNCTION BOX (1900 BOX)
W
B
W
B
JUMPER
W
B
2 WIRE
B
W
B
LOW
SINGLE HIGH LIMIT AQUASTAT
W
B B
2 WIRE
2 WIRE
2 WIRE
W
W
B
2 WIRE WHT BLK
WHT BLK
CIRCULATOR
CIRCULATOR
2 WIRE WHT
B CAD CELL
W
W
B
BLK
CIRCULATOR
B B
W B
IGNITION TRANSFORMER
B = BLACK WIRE W = WHITE WIRE R = RED WIRE
BURNER PRIMARY CONTROL
BB
B = BLACK WIRE W = WHITE WIRE R = RED WIRE
246 16_Troubleshooting_p295.indd 246-247
F
T
T
BURNER MOTOR
F.W. Webb Company
B
IGNITION TRANSFORMER
W OR B F
CAD CELL
B B W OR B F F
T T
BURNER PRIMARY CONTROL
BURNER MOTOR
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
247 3/24/08 4:30:03 PM
SECTION
SECTION
16
16
Boiler Controls: Triple Aquastat (L8124A)
POWER SUPPLY CIRCUIT BREAKER
LOW VOLTAGE THERMOSTAT LOW VOLTAGE THERMOSTAT
L2 (NEUTRAL) SERVICE OR EMERGENCY SWITCH
12
T T
B 2 B1
LOW VOLTAGE THERMOSTAT
SWITCHING RELAY PRIMARY CONTROL
T T JUMPER TRIPLE 6 AQUASTAT 4 CONTROL 2 1 3 5
L1 (HOT)
troubleshooting
POWER SUPPLY CIRCUIT BREAKER
Boiler Controls: Low Voltage Thermostat
T T
RA117A STACK RELAY
L2 (NEUTRAL) F F
TRIPLE AQUASTAT CONTROL
L1 (HOT) SERVICE OR EMERGENCY SWITCH
C2 C1
12
T T ZRZ C
T T 1 2 3
B2 B1 C 2 C1
16 IGNITION TRANSFORMER
CIRCULATOR IGNITION TRANSFORMER
24V WIRE
STACK RELAY RA117A
POWER IN B
W W
B
NOT SHOWN ADDITIONAL ZONE WIRING R845A RELAY
T
T
THERMOSTAT 24V
BURNER MOTOR
JUMPER R
WHT 2
2 WIRE
1
4
3
BLUE BLK
WHT
WHT
BLK
B
T
T
2
RED
4 WIRE
B W
BLK
3 WIRE
BURNER MOTOR
EMERGENCY SWITCH
W
T T
B
WHT
2 WIRE
WIRE
POWER IN
1
BLK
BLK
WHT
RED
W
2 WIRE
CIR
5
3 MOTOR 4 IGNITION 3
3 WIRE
6
EMERGENCY SWITCH
2 WIRE
6
4
2 WIRE
2
BLUE 3
B = BLACK WIRE W = WHITE WIRE R = RED WIRE
R845A
T
T
BLK
WHT
L2
WHT
BLUE
WHT BLK
T
T
BLK
BLK
WHT
THERMOSTAT 24V
WHT
2
1 BLUE
3
WHT
CIR
4
WHT
BLK
B1
B2
RED
ZR
2 WIRE
W
B
24V WIRE
R
B C2
BLK
WHT
BLUE WHT
BLK
IGNITION TRANSFORMER
B B
B B
CAD CELL
WHT
NOT SHOWN ADDITIONAL ZONE WIRING R845A RELAY
WIRE
BLUE RED
BLUE
R845A
ZC
ZR B2
B1
C1 C2
BLK WHT
BLUE
WHT
BLK
T T
THERMOSTAT 24V IGNITION TRANSFORMER
T
L8124A AQUASTAT RELAY
CIR
1ST ZONE THERMOSTAT 24V
B
T
WHT
BURNER MOTOR
WHT
BLK
L2
BLK
WHT BLK
W
BLUE
WHT
L1
2 WIRE
4 WIRE
WHT
C1
BLK
2 WIRE
BLK
WHT
RED
4 WIRE
B
BLUE
ZC
WHT BLK
5 WHT
RED
WHT
BLK
WHT
L8124A AQUASTAT RELAY
BLUE
6
CIR
5
1
L1
technical information
CIRCULATOR
CIRCULATOR
BURNER PRIMARY CONTROL
BB
2 WIRE WHT
2
3
6
4
1 BLUE 1
WHT
CIR WHT BLK
4 WIRE
5 RED
WHT
BLK
CIR
W OR B BURNER MOTOR
F
F
T T
2 WIRE
16_Troubleshooting_p295.indd 248-249
F.W. Webb Company
BLK
1st ZONE THERMOSTAT 24V
B = BLACK WIRE W = WHITE WIRE R = RED WIRE
248
WHT
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
249 3/24/08 4:30:05 PM
Technical Information
SECTION
SECTION
16
16
Technical Information
R7184 Series Primary Controls TECHNICIAN’S QUICK REFERENCE GUIDE
Any time the motor is running, press and hold the reset button to disable the burner. The burner will remain off as long as the button is held and will return to standby when released.
The following service procedures will help you become familiar with the R7184 series primary controls. For control operation, please refer to the basic control functions described on the next page. For further information, wiring instructions and troubleshooting, please refer to the R7184 Installation Instructions, form number 69-1233.
Table 1. LED indicator Key
Priming the Pump
Cad Cell Resistance Check
STANDBY
status
On
Flame sensed.
Off
Flame not sensed.
Flashing (1/2 sec. on, 1/2 sec. off)
Lockout/Restricted Lockout.
Flashing (2 sec. on, 2 sec. off)
Recycle.
While the burner is firing, and after the ignition has been 2. While the ignition is on, press and release the reset turned off, press and release the reset button (hold 1/2 button (hold 1/2 second or less). If the control has second or less) to check the cad cell resistance. The LED will flash 1 to 4 times, depending on the cad cell not locked out since its most recent complete resistance (see Table 2). For proper operation, it is im heat cycle, the lockout time will be extended to 4 portant that the cad cell resistance is below 1600 ohms. minutes (45 seconds in earlier units), and the ignition will remain on for the entire heat cycle. Table 2. Cad Cell Resistance 3. Bleed the pump until all froth and bubbles are LED Flashes Cad Cell Resistance (ohms) purged. If prime is not established within the 0—400 1 extended lockout time, the control will lockout. 400—800 2 Press the reset button to reset the control and 800—1600 3 return to step 2. S1600
NOTE: The reset button can be held for 30 seconds at any time to reset the control’s lockout counter to zero and send the control to standby. Table 3. R7184 Series Control Features 4. Repeat steps 2 and 3, if needed, until the pump is model Advanced features fully primed and the oil is free of bubbles. Then Interrupted ignition microprocessor-based control. R7184A terminate the call for heat, and the control will All features of the R7184A plus a 15-second R7184B valve-on delay. resume normal operation.
Resetting From Restricted Lockout
If the control locks out three times in a row without a complete heat cycle between attempts, the lockout becomes restricted in order to prevent repetitious resetting by the homeowner. To reset, hold down the reset button for 30 seconds (until the LED flashes twice).
250 16_Troubleshooting_p295.indd 250-251
F.W. Webb Company
a
Typical Sequence of Operation (Fig. 1) 1
led
4
6. RUN. The burner runs until the call for heat is satisfied. The burner is then sent to burner motor-off delay, as applicable, or it is shut down and sent to standby.
R7184Pa
All features of the R7184B plus a burner-off delay: field-selectable 1/2, 2, 4 or 8 minutes.
R7184P/R7184U
All features of the R7184P above, plus dry alarm contact terminals (30 Vac, 2A maximum). All delays can be field disabled together by a DIP switch setting.
. Burner-off delay timings may be different.
www.fwwebb.com
2
VALVE-ON DELAY
3
5
8
MOTOR-OFF DELAY
TRIAL FOR IGNITION
4 LOCKOUT
8. BURNER MOTOR-OFF DELAY. If applicable the fuel valve is closed and the burner motor is kept on for the selected burner motor-off delay time before the control returns the burner to standby.
IGNITION CARRYOVER
6
7 RUN
7. RECYCLE. If the flame is lost while the burner is firing, the control shuts down the burner, enters a 60-second recycle delay, and then repeats the ignition steps outlined above. If the flame is lost three times in a row, the control locks out to prevent cycling with repetitious flame loss caused by poor combustion.
RECYCLE
Fig. 1 Typical sequence of operation. 1. STANDBY. The burner is idle, waiting for a call for heat. When a call for heat is initiated there is a 2- to 6-second delay while the control performs a safe start check.
16 technical information
1. Initiate a call for heat.
R7184 Series Primary Controls (continued)
troubleshooting
5. IGNITION CARRYOVER. Once flame is established, the ignition remains on for 10 seconds to ensure flame stability. It then turns off.
Disable Function
2. VALVE-ON DELAY. As applicable, the ignition and motor are turned on for a 15-second valve-on delay. 3. TRIAL FOR IGNITION (TFI). The fuel valve is opened, as applicable. A flame should be established within the 15-, 30-, or 45-second lockout time. 4. LOCKOUT. If flame is not sensed by the end of the TFI, the control shuts down on safety lockout and must be manually reset. If the control locks out three times in a row, the control enters restricted lockout. Follow the instructions on the front of this card to reset the control.
The F.W. Webb Heating Catalog
F.W. Webb Company
251 3/24/08 4:30:06 PM
3
L1 “DIP Switch S1 - Field Settings” on page 11. Harness NOTE: See Control powered- Call for heat Not Flash Applicable (normal operation) NOTE: Any connector can be used. EnviraCOM thermostats Connector Trial For Ignition =Heartbeat 6 seconds Red LED Status Code Table 6. DIP Switch (S1) settings - Field XFMR Heatsettings. Fan OFF Delay - 60 seconds ON ON Flame present 4 Pressure Switch ope - Ignition Activation Period = 3 seconds a Fixed parameters are those settings which may not be adjusted at any and Error Description Code Straight Spade Flame Flame Sense Signal Input (90 Vac, current limited) CONT EnviraCOM™ diagnostic or communications device Trial For Ignition or R - Flame Recognition Period = 3 seconds Straight Spade COOL Circulator cool speed output Individual Switches HEAT FAN OFF DELAY time. Periodic Blink Call for heat - Low flame current Check: Flame rod for contamination or loose Quick Connect HEAT Quick Connect FUSE b DIP Switch S2 – Safety Timings Pulse Control powered (Standby; No wiring; low gas pressure. HSI Igniter Warm-up Time = 30/30 seconds ON ON EAC Electronic Air Cleaner 120 Vac Output EAC DIP Switch S1 Descriptions SW1 SW2 SW3 SW4 24 VAC 12-pin connector Main Harness See Table 2 on page 7. Call for Heat)Limit Code Table 7. DIPTrial Switch (S2) S1 For Ignition = 8settings seconds - Safety timings Table 5. Fixed Parameters Connector Heartbeat Call for heat Flame sense out of Check/Repair: Flame at burners, if present HEAT SECTION Circulator heat speed output - Ignition Activation Period = 5 seconds COM FLAME SECTION COOL Cool Fan OFF Delay - 0 seconds OFF 10 7 4 1 Heartbeat Call for Heat - Normal Individual Switches 5 valve. Limitoperation switch o - Flame still present replace gas - Flame Recognition Period = 3 secondssequence Fixed Parameter Setting Straight Spade 24 VAC Transformer - 24 Vac CONT Continuous circulation M24909 Cool Fan OFF Delay - 60 seconds ON Pressure Switch Codes Quick Connect OFF AllSW1 other conditionsSW2 Not Applicable DIP Switch S2 Descriptions PLASTIC MOUNTING TRAY Pre-Purge 30 seconds a COM Transformer - Common XFMR Transformer 120 Vac Output The shorter of the two periods listed (17 seconds) applies to the first trial only, M24908 Fig. 2. DIP Switch (S1) Shown with factory default settings; all off 2 Pressure Switch failed Open while theWarm-up longer Time period (27aaseconds) applies to theOFF subsequent OFF trials during the Inter-trial Purge 60 seconds HSI Igniter = 17/27 seconds Fuse Block Fuse Fuse - Automotive Type - 3.0 Amps L1 Flash Code Descriptions: Line 120 Vac hot power supply Heat Fan ON Delay 30 seconds OFF sameTrial callFor forIgnition heat. = 4 seconds NOTE: FIELD SETTINGS (Page 11) Pulse: A 0.25 second flash followed by 3.75 seconds of off time. Fig. 1. Typical Mounting Orientation showing wiring connections to Postpurge the 15 seconds - Ignition Activation Period = 1 second Humidifier 120 Vac output S9200U1000 Heat Fan ON Delay - 60 seconds ON Table 4. Wiring Connections (Class 1, Line Voltage). HUM Heartbeat: Constant 0.5 second bright 0.5 second dim cycles. LED INDICATORS - Flame Recognition Period = 3- seconds The field settings can change EGRATED FURNACE CONTROL Coolbe Fanchanged ON Delay whenever necessary. The 5 seconds - Periodic Blink: 0.5 second on, 0.5 second off. During local history recall, this faultFlame Cod This is the default setting. PARK Circulator Motor Park 120 Vac Input The S9200U1000 provides three indicating LEDs (See Fig. 4 on page 9 takes effect for the next situations which are being influenced by that Connection is flashed as a 1 + 2 pattern. Ignition Retries retries (3 retires total) 6 Unexpected flame for location on board): change. If for example a particular delay is Fan in progress settings are COOL FAN OFF Heat OFF Delay2- and 120 seconds OFF OFF ON Circulator Motor Park 120 DELAY Vac Input Terminal Type (see Fig. 4) Connects S9200U1000 to:PARK Pressure Switch failed HSI Igniter Warm-upOFF Time = 17/27ba seconds During local history recall, this fault is flashed as a 1 +32 pattern. flame to beClosed off afte changed, the currentIgnition delayRecycles setting is not influenced by3 that change. The Trial Flame For Ignition =Amber: 6 secondsindicates flame status recycles (4 cycles total) second dela — Heat Fan OFF Delay 180 seconds OFF ON Neutrals 120 Vac Input Neutral, Transformer Neutral, Electronic Recalling the Status Code History ENVIRACOM COMMUNICATIONS 4-pin connector • IgniterSeeStraight Table 3Spade on page 8 Table field settings are not considered safety critical therefore, changes to Ignition Activation Period = 3 seconds s 12. Test Mode Parameters HEATCirculator FAN ON DELAY Table 9. Control Status Codes — Status Red: indicates general system status and error Quick Connect Air Cleaner Neutral, Neutral, Humidifier (male terminals) Inducer Autobe Restart Delayat any time 1installation. hour - Flame Recognition Period = 3 seconds these parameters can made during and -after Soft Lockout C You may perform the following procedure multiple times to confirm that Heat Fan OFF Delay 90 seconds ON OFF EnviraCOM™ communication is a standard featureHarness on the Neutral Timing codes. ed have Timing Test Mode Parameter Modified ou viewed all the currently stored error codes. Flash S9200U1000. EnviraCOM™ can be used to controlConnector system operation HSI— Igniter Time = 30/30 seconds OFF Red LEDON Status Code NOTE: See “DIP Switch S1 - Field Settings” onHeat pageFan 11. OFF Delay - 60 seconds ONWarm-up ON E-COM Green: indicates EnviraCOM™ bus activity WIRING CONNECTIONS NOTE: Any connector can be used. Fixed Parameter Setting Trial For Ignition = 6 secondsCode a by way of an EnviraCOM™ enabled thermostat and perform advanced seconds Pre-Purge 5 seconds Red LED Statu and Error Description Check /Flash Repair MOUNTING HOLE (X2) o recall the error code history and display it via the red status LED, Straight Spade COOL Circulator cool speed BOARD outputCLIPS (X6) HEAT FAN OFF DELAY Pressure - Ignition Activation Period = 3 seconds 2 69-2087 69-2087 are those settings which 3 may not be adjusted at any 4 69-2087 4 69-2087 a Switch opened during diagnostics when connected to EnviraCOM™ tools Fixed parameters Straight Spade Flame Flame Sense - Signal Input (90 Vac, current limited) Code and Error Desc See- Flame “Troubleshooting” on page 19 for information about specific flash Quick Connect enabled erform Table 3. Wiring Connections (Class 2,diagnostic Low Voltage). Flame Failure ResponseDIP Time Switch S2 – Safety 2 seconds (maximum) Trial For Ignition or Run Mode Recognition Period = 3 seconds seconds the following: HSI Warm-up 17 seconds Timings Pulse Control powered (Standby; No Not Applicable such as the web based EnviraLNK® remote diagnostics application, theElectronic Air time. EAC Cleaner 120 Vac Output Quick Connect 1 4 codes as referenced in the checkout procedures. PARK PARK HUM Call for Heat) Table 7. DIP Switch (S2) settings - Safety S1 2+1 Soft Lockout - Exceed OnWatch QuickLook™ 72Connection and the W8735D Telephone Access Module Fault De-bouncing Time 2 seconds 1. Jumper the thermostat screw-terminal R/2 to HSItimings Igniter Warm-up Time = 30/30 seconds ON ON seconds Ignition Activation 3 seconds HEAT and flame Circulator heat speed output number of retr (TAM). InTerminal additionType to alarms, key information such as state Limit Code Trial For Ignitionprocedures = 8 secondsHeartbeat Use the following only forCall theforintegrated Table 5. Fixed Parameters terminal D/1. Heat - Normalfurnace operation control; Not Applicable (normal operation) (see Fig. 4) Connects S9200U1000 to: Individual Switches Compressor Short Cycle Delay 5 minutes second • Flame Recognition 1 second Ignition Activation Period = 5 seconds current can be sent over the EnviraCOM™ bus. See Table see- individual component instructions for additional checkout Within 0.5 seconds, the red status LED stops normal CONT 13. Continuous circulation M24909 5 Limit switch open Flame Recognition Period = 3 seconds Fixed Parameter Setting Pressure Switch Codes screw D/1 (optional) EnviraCOM™ Data Connection (if used) procedures. operation and turns on solid to indicate that the jumperaisquick overview for6-position Switch S2 20 Descriptions SW1 SW2 Flameprocedure Recognition Period seconds seconds Trial for Ignition 4 seconds This following service procedure provides the This following False service provides aDIP quick overview for the terminal XFMR Transformer 120 Vac Output Table 11. S920001000 EnviraCOM Alarms sensed. Fig. 2. DIP S2 Switch (S1) Shown with factory default IFC. settings; all off information, refer to form 69-2075. 2 Pressure Switch failed Open Check: If inducer is running, inducer could be Pre-Purge 30 seconds C/3 24 volt ground S9200U IFC. For more information, refer to form 69-2075. S9200U For more a The shorter (#5 screw) Heat Cycles to Safety Timings Selection LockHSI Igniter Warm-up Time 10=cycles OFF seconds Heat Fan ON Delay 15 seconds of the two OFF periods Table listed (17 appliesCodes to the first trial only, broken or disconnected, or inducer relay K4 may 17/27a seconds 2. Keep the thermostat screw-terminal R/2 to D/1 jumpered. 8. seconds) Flame status L1 Line 120 Vac hot power supply 2+3 Soft Lockout - Exc NOTE: FIELDS1SETTINGS (Page 11) Trial For Ignition = 4 seconds while the longer period (27 seconds) applies to the subsequent trials during the Inter-trial Purge 60 seconds R/2 Alarm 24 volt hot - Thermostat After a 5 second time-out, the red status LED turns off, have failed. seconds • Heat Fan OFF Delay 0 seconds maximum Ignition Activation Period = 1 second WIRING HARNESSES WIRING HARNESSES Flash Alarm Description Number Comment same call for heat. Amber LED Status Code HUM Humidifier 120 Vac output Check/Repair: Low line voltage; Pressure switchnumber of indicating that error code recall is pending. DIP Switch (S1 and S2) settings - Flame Recognition retries where the las Period = 3 seconds Postpurge 15 seconds W Thermostat Heat Input wiring loose; hose disconnected or leaking; a The field settings can be changed whenever necessary. The change seconds Post-Purge 5 seconds and Error Description Check / Repair Code The following field and safety parameters may be set using DIP Table 1. Main harness plug connector 12-pin This device has no alarms Table 1. Main harness plug connector 12-pin retry was due to the This is the default setting. PARK Circulator Motor Park 120 Vac Input LED INDICATORS 0 Not Applicable water in hose; venting blocked or obstructed. E-COM takes effect for the next situations which are being switches influenced byand thatS2. Refer to Fig. 4 on page5 seconds Cool FanS1 ON Delay G Thermostat continuous fan input switch openin Flame Code 9 for the location of the two (Class 2, Low Voltage) (Class 2, Low Voltage). 3. Within 10 seconds of the red status LED turning off, remove the. seconds Cool Fan ON Delay change. If for example 2 seconds a particular delay is in progress and settings are The S9200U1000 provides three indicating LEDs (See Fig. 4 on page 9 a seconds OFF Control poweredNo flame Not Applicable (normal operation) OFF ON PARK Circulator Motor Park 120 Vac Input Pressure switch failed to close in the ignition 1 Display/Diagnostics 3 Pressure Switch failed Closed Check: If inducer is off; inducer relay (K4) could HSI Igniter Warm-up Time = 17/27 DIP switch blocks. thermostat screw-terminal Ignition Retries The retries retires=total) Y Thermostat cool input / cooling contactor output for 2 Unexpected +4 Soft Lockout Exc 6 be welded. flame - Waiting- for delay setting is notL1influenced change. Pin # R/2 to terminal Function Pin #by that Function2Trial for location on board): sequence For(3Ignition 6 seconds seconds D/1 jumper. Cool Fan OFF Delay changed, the current 0 seconds Heartbeat Control powered- Call for heat Not Applicable (normal operation) EnviraCOM Straight Spade Neutrals thermostats 120 Vac Input Neutral, Transformer Neutral, Electronic maximum flame(shorted); to be off after number the 20 o field settings are not considered safetyXFMR critical therefore, changes to Check/Repair: Terminal wiring -settings Ignition Activation Period = 3 seconds (S1) - Field settings. 1 High Limit Out 1 High Limit Ignition Table Recycles6. DIP Switch 3Out recycles (4 cycles total) Flame present Quick where the last recycle • This activates the error code recall. second delay Pressure switch failed to open in the ignition 3 Connect Display/Diagnostics Air Cleaner Neutral, Circulator Neutral, Humidifier — Flame - Amber: indicates flame status pressure switch contacts (closed when should - Flame Recognition Period = 3 seconds these parameters can be made at any CONT time during and afterFlame installation. 3-pin E-COM EnviraCOM™ diagnostic or communications device 2 Flame Sense - Flame Signal Input (90 Vac, current Polarized limited) 2 Sense - Flame Signal Input (90 Vac, current limited) Neutral sequence Switches — Periodic Status system status beor open); have watera flame failu Auto Restart Delay 1Individual hour Blink- Red: Call indicates for heat - Lowgeneral flame current Check: Flameand rod forerror contamination loosepressure switch hoses connector Soft Lockout Codes HEAT FUSE HSIHot Igniter Warm-up Time = 30/30 seconds ONb OFF 3 24 Vac Hot 3 24 Vac MPORTANT build-up or obstruction. codes. NOTE: See “DIP Switch S1 Field Settings” on page 11. wiring; low gas pressure. 2+5 Soft Lockout - Exc The pressure switch opened in run or trial 98 Display/Diagnostics NOTE: Any connector can be used. Trial For Ignition = 6 seconds EAC DIP Switch S1 Descriptions SW1 SW2 SW3 SW4 If the R/2 to D/1 terminal jumper is not removedNot within the 24 VAC 12-pin See Table 2 on page 7. 4 Used (TBD) 4 Not Used -(TBD) maximum number o for more than connector the allowable timeMain Harness 4 Pressure Switch opened during Check: See if inducer is running. Ignition Activation Period = 3 seconds Fixed parameters are those settings which may not be adjusted at any ConnectorStraight Spade 10 seconds, the history will be erased. — E-COM indicates EnviraCOM™ bus activity Heartbeat - Green: Call for heat - Flame sense out of TrialCheck/Repair: Flame at burners, Check/Repair: if present where the last recycle Flame Flame Sense - Signal Input (90 Vac, current limited) 5 Rollout Switch Out WIRING CONNECTIONS 5 Rollout Switch Out For Ignition or Run Mode Restricted venting; low input Flame Recognition Period = 3 seconds COM FLAME COOL Fixed Parameter Setting Flash Cool Fan OFF Delay 0 seconds OFF 10 7 4 69-2087 69-2087 3 4 present 69-2087 5 Red LEDtheStatus Code time.12 MOUNTING HOLE (X2) Limit switch open 26 Connect Display/Diagnostics sequence - Flame still replace gas69-2087 valve. limit circuit open Quick BOARD CLIPS (X6) voltage; water inahorizontal vent length. Straight Spade 24 VAC Transformer - 24 Vac 24LED, Vac Common 6 24 Vac Common limitDescription remained open l Code and Error 4. Each saved error code6 blinks once on the red status See “Troubleshooting” on page 19 for information about specific flash HSI Igniter Warm-up Time = 30/30 seconds ON ON Table 3. Wiring Connections (Class 2, Low Voltage). Cool Fan OFF Delay 60 seconds ON Flame Failure Response Time 2 seconds (maximum) Quick Connect Flame detected out of sequence 34 Display/Diagnostics OFF All other conditions Not Applicable PLASTIC MOUNTING TRAY three minute 7 High Limit In + Pressure Switch Out 7 High Limit In + Pressure Switch Out Limit Code — E-COM Green: indicates EnviraCOM™ bus activity Trial For Ignition = 8 seconds 1 4 WIRINGstored CONNECTIONS Table 5. Fixed ParametersSetting starting with the most recently error code. codes as referenced in the checkout procedures. PARK PARK HUM COM Transformer - Common Fixed Parameter Flash M24908 — E-COM Green: indicates EnviraCOM™ bus activity 2+1 Soft Lockout - Exceed maximum Red LED Status Code - Ignition Activation Period = 5 seconds Fault De-bouncing Time 2- seconds Connection MOUNTING HOLE (X2) 8 WIRING CONNECTIONS Chassis Ground Soft lockout due to flame current 5BOARD CLIPS (X6) Display/Diagnostics 8 Setting Chassis Ground FixedParameter Parameter Flash a integrated afollowing switch open restricted airflow number through of heat Red Limit LEDDescription Status Code Check: Wiring; retries - Flame Recognition Period 19 = 3 seconds Fuse Block(see Fig. 4) Fuse Fuse - Automotive Type - 3.0 AmpsMOUNTING HOLE (X2) Fixed Setting BOARD CLIPS (X6) Use the procedures onlyCode for 5the control; Flash Code Descriptions: OTE: If there are no error codes to display, the red status LED immediately returns to nor-(ClassTerminal Check /filters; Repair See “Troubleshooting” on page for information about specific flash Type Connects S9200U1000 to: Table 3. Wiring Connections 2, Low Voltage). Heat Fan ON Delay 30 seconds OFF Flame Failure Response Time 2 seconds (maximum) a and Errorfurnace 2 + slow 6 circulator Soft Lockout 9 Valve Common Soft Lockout due to recycle; last recycle 9 Compressor Short Cycle Delay Main Valve Common5 minutes exchanger; clogged fan - Gas Va Code and Error Description Check / Repair mal operation. 85 Display/Diagnostics See “Troubleshooting” on page 19 for information about specific flash Table 3. WiringMain Connections (Class 2, Low Voltage). see individual component instructions for additional checkout Pulse: A 0.25 second flash followed by 3.75 seconds of off time. 1 4 Flameshowing Failure Response 2 seconds (maximum) Fig. 1. Typical Mounting Orientation wiringTime connections to the codes as referenced in the checkout procedures. PARK PARK HUM to Make speed. Pre-PurgeTime 30 secondsHeat Fan ON Delay - 60 aseconds 10 Pressure Switch In 10 Pressure was from pressure switch open 1 4 2 +bright 1 Softsecond Lockout -dim Exceed maximum Check/Repair: Gas supply (pressure, supply, ON checkout codes as Switch referenced in the procedures. PARK PARK HUM Fault De-bouncing 2False seconds 6-position screw D/14. (optional) EnviraCOM™ Data Connection used) Connection S9200U1000 Table Wiring Connections (Class 1, Line(ifVoltage). Constant 0.5 cycles. procedures. The shorter of theIn20 two periods listed (17 seconds) applies- Heartbeat: to the first trial only, 0.5 second Flame Recognition Period seconds 2+1 Soft Lockout - Exceed maximumshut-off Check/Repair: supply (pressure, supply,Other Code Fault De-bouncing Time seconds number of retries valves, gas Gas valve); ignition (HSI element 5. After last error code displays, the Type red status LED to norConnection terminal UseRollout the following procedures only for the integrated control; S2 11 Terminal Rollout Switch In 11602 seconds Switch In -furnace Periodic Blink: 0.5the second on, 0.5 second off. During local history recall, this fault while the longer period (27 seconds) applies to the subsequent trials during (see Fig.returns 4) Connects S9200U1000 to: Repair: Remove restrictions. Increase airflow Inter-trial Purge The maximum number of flame loss 22 Display/Diagnostics number of retries shut-off valves, gas valve); (HSI element 24 volt ground Compressor Short Cycle Delay 5 minutes not properly positioned and ignition glowing); flame Use thecall following procedures only for the integrated isfurnace (#5 screw) mal operation. Heat12 Cycles to Safety Timings Selection Lock (see Fig. Main 4) Valve Connects S9200U1000 to: C/3Connection see individual through furnace (increase motor speed, open flashed control; asTable a 1 + 28. pattern. same forcomponent heat. 10 cyclesinstructions for additional checkout Flame status Codes 12 Terminal Type Main Valve incidents has been exceeded Short Cycle Delay 5 minutes not properly positioned flame sensing (lead-wire grounded, flame 3or+and 1 glowing); Low 24V (Control res COOL FAN OFF DELAY Compressor see individual component instructions additional Heat Fan OFF Delay - 120 seconds OFF forOFF 6-position screw D/1 (optional) EnviraCOM™ Data Connection used) R/2(see Fig. 4) 2ducts, + 3broken Lockout - Exceeded Postpurge Period seconds more add more returns). Terminal(if Type Connects S9200U1000 to: procedures. b checkout 24 volt hot - Thermostat False Flame Recognition 2015 seconds sensing (lead-wire broken orSoft grounded, flame rod not properly positioned, or flame rod During local history recall, this fault is flashed as a 1 + 2 pattern. recover S1 6-position screw D/1 (optional) EnviraCOM™ Data Connection (if used) procedures. terminal maximum number oferror recycles or LED INDICATORS Soft Lockout due to recycle; last recycle 86 Display/Diagnostics False Flame Recognition Period 20 seconds S2 Flash rod not properly positioned, or flame rod contamination); low line voltage. Amber LED Status Code DIP Switch (S1Heat and FanS2) OFFsettings Delay -Connections 180 seconds OFF ON C/3 24 voltwas ground ON Delay seconds terminal Flame Code Igniter/Inducer Harness Plug Connections Igniter/Inducer Harness Plug (#5 screw) where the last recycle/ 4-pin connector • IgniterSee Table 3 on page 8 S2 from limit switch open Heat Cycles to Cool SafetyFan Timings Selection Lock 105 cycles W Thermostat Heat Input a Fig. contamination); lowretries line voltage. Table 8. Flame status Codes The S9200U1000 provides three indicating LEDs (See 4 on page 9 C/3 24 volt (male groundterminals) HEAT FAN ON DELAY Table 9. Control Status Codes (#5 screw) and Error Description Check / Repair Code The following field and safety parameters may be set using DIP retrywiring; was due to the pressure Heat Cycles to Safety Timings Selection Lock 10 cycles Inducer 2 + 3 Soft Lockout Exceeded Check/Repair: Pressure switch slow Table 8. Flame status Codes E-COM Heat Fan OFF Delay 90 seconds ON OFF Table 2. Igniter/Inducer harness plug Connector 4-Pin Table 2. Igniter/Inducer harness plug Connector 4-Pin R/2 24 volt hotGas - Thermostat Ignition Retries 2 retries (3 Unexpected flame- Exceeded - Waiting for Check/Repair: Gas valve leakage. location board): S1 valve failed to energize 17 Thermostat Display/Diagnostics/EnviraLNK®/TAM G Harness continuous fan input switch switches S1retires andtotal) S2. Refer to Fig.for 4 on page on 9 for the location of the two 26+ 3 maximum Soft Lockout Check/Repair: switch wiring; opening slow recycles restricted,Pressure excessive, or obstructed R/2 24 volt hot - Thermostat Flash flamenumber to number be(normal offofafter the 20or or inducer; FlashControlRed S1 OFF poweredflame Code Not Applicable operation) Amber LED Status Code DIP Switch (S1Ignition andRecycles S2) settings Connector LEDNoStatus maximum ofrecycle/ recycles inducer; restricted, excessive, or obstructed DIP switch retries where the last venting; unstable line voltage. Heat Fan OFF Delay Lettering - 60 seconds ON flameON Flash W Thermostat HeatisInput 3 recycles cycles total) Pin # Reference Lettering Function Pin # (4 blocks. Reference Function a Flame second delay Amber LED Status Code Low voltage detected on 24 Vac 125 Display/Diagnostics/EnviraLNK®/TAM — Amber: indicates status Y input Thermostat cool input / cooling contactor output for 2 + 4 Soft Lockout - Exceeded DIP Switch (S1 and S2) settings a L1 retries where the last recycle/ venting; unstable line voltage. and Error Description Check / Repair Code The following field and safety parameters may be set using DIP retry was due (normal to pressure W Thermostat Heat Input and Error Description Check / Repair Code Heartbeat Control poweredCall for heat Not Applicable operation) thermostats E-COM EnviraCOM maximum number of recycles Straight Spade COOL Circulator cool speed output HEAT FAN OFF DELAY — a Status indicates general system status and error and- Red: Error Description Check / Repair The following safety parameters using6. DIP retrySoft wasLockout due to the pressure DIP Switch (S1) Code settings - Field settings. G Thermostat fan input Autofield Restart Delay 1 Table hour XFMR switch opening switches S1 and S2. and Refer to Fig. 4 on page may 9 for be the location of the two 1 IND-HOT 120has Vac 1 set IND-HOT Inducer 120 Vac Codes AInducer badcontinuous fuse been detected (NOTE: This 92 E-COMDisplay/Diagnostics/EnviraLNK®/TAM Flame present where the last recycle was due to Quick Connect codes. G Thermostat continuous fan input OFF Control poweredNo flame Not Applicable (normal operation) switch opening DIP Switch S2 – Safety Timings switches S1 and S2. Refer to Fig. 4 on page 9 for the location of the two Pulse Control powered (Standby; No Not Applicable 3+2 CONT DIP switch blocks. alarm is stored in the Status Code History) Polarized 3-pin E-COM communications device EAC EnviraCOM™ diagnostic ElectronicorAir Cleaner 120 Vac Output a flame failureBad Fuse OFF Control-Igniter poweredNo flame Not Applicable operation) Individual Switches Y Thermostat cool Igniter inputconnector / cooling 2 + 4 Check: Flame Soft Lockout - Exceeded or loose Check/Repair: Gas supply; flame sensor wiring. 2 IGN-HOT 120 Vaccontactor output for 2 120 Vac L1 forcurrent Heat) DIP switch blocks. Table 7.IGN-HOT DIP Switch (S2) settings Safety timings Periodic Blink (normal Call for heat - LowCall flame rod for contamination S1 HEAT Heartbeat Control powered- Call for heat Not Applicable (normal operation) Y ThermostatEnviraCOM cool /thermostats cooling contactor output FUSE 2+4 Soft Lockout Check/Repair: Gas supply; flame sensor wiring. maximum number ofExceeded recycles L1 b Theinput gas valve relay was sensed asfor closed 100 Display/Diagnostics/EnviraLNK®/TAM wiring; low gas -pressure. HEAT Circulator heat speed output Table 6. DIP Switch (S1) settings Field settings. XFMR 2 + 5 Soft Lockout Exceeded Heartbeat Control poweredCall for heat Not Applicable (normal operation) Flame present EnviraCOM thermostats numberwas of(normal recycles theNot lastApplicable recycle due to 5operation) DIP S1 Descriptions SW1 SW2 SW3 3 IND-NEUTRAL Inducer Neutral 3 Switch IND-NEUTRAL Inducer Neutral SW4 Heartbeat Call for Heat - Normal operation wheremaximum 2 69-2087 69-2087 3 settings - Field 4Switches 69-2087 69-2087 Individual 24 VAC when it should beMain open Table 6. DIP Switch EAC (S1) settings. 12-pin connector Harness See Table 2 on page 7. XFMR maximum number of recycles Flame present CONT Polarized 3-pin E-COM EnviraCOM™ diagnostic or communicationsConnector device CONT where atheflame last recycle was due to failure Continuous circulation Individual Switches M24909 Heartbeat Call for heat Flame sense out of Check/Repair: Flame at burners, if present where the last recycle was due to CONT Periodic Blink Call for heat Low flame current Check: Flame rod for contamination or loose Polarized 3-pin E-COM EnviraCOM™ diagnostic or communications device connector 4 IGN-NEUTRAL Igniter Neutral 4 Cool FanSwitches Igniter Neutral a flame failure Pressure Switch Codes COM FLAME COOL OFF Delay - IGN-NEUTRAL 0 secondsS2 Descriptions OFF HEAT 10 Individual 7 4 1 Electronics down 18 Display/Diagnostics/EnviraLNK®/TAM FUSE DIP Switch SW1current SW2 sequence - or Flame valve. the limit circuit opening or the Periodic Blink Call for heat - Low flame Check:wiring; Flame low rod gas for contamination loosestill present2 + 5 b pressure. connector Softreplace Lockoutgas - Exceeded Check: Wiring; restricted airflow through heat HEAT Transformer 120 Vac Output FUSE Spade 24 VAC XFMR Transformer - 24 Vac EAC DIP Switch S1 Descriptions SW1 SW2 SW3 SW4 b Fig. 2. DIP Switch (S1) Shown with factory default settings; all off limit remained open longer than wiring; low gas pressure. 24 VAC 12-pin connector Main Harness See Straight Table 2 on page 7. 2 + 5 Soft Lockout Exceeded Check: Wiring; restricted airflow through heat 2 Pressure Switch failed Open Check: If inducer is running, inducer could be Cool Fan OFF Delay - SW4 60 seconds ON maximum of recycles exchanger; clogged filters; slow circulator Reversed line polarity 33 Display/Diagnostics/EnviraLNK®/TAM24 VAC Quick Connect OFF OFF DIP Switch S1 Descriptions SW1 SW2 SW3 OFF other conditions Notnumber Applicable PLASTIC MOUNTINGEAC TRAY HSI Igniter Warm-up Time = 17/27a seconds minutes 12-pin connector Main Harness See Table 2 on page 7. Connector maximum numberwas of recycles filters; slowthree circulator broken disconnected, or inducer relayexchanger; K4 may clogged Heartbeat Call for heat - Flame sense out of Check/Repair: Flame at burners,All if present where theor last recycle due to fan speed. L1 Line 120 Vac hot power supply COM Transformer - Common COM FLAME COOL Cool Fan OFF Delay 0 seconds OFF 10 7 4 1 Trial For Ignition = 4 seconds NOTE: FIELD SETTINGS (Page 11) Connector M24908 Heartbeat Call for heat Flame sense out of Check/Repair: Flame at burners, if present where the last recycle was due to fan speed. have failed. sequence Flame still present replace gas valve. Earth ground problem 88 Display/Diagnostics/EnviraLNK®/TAM COM FLAME the limit circuit opening or the 3+4 Gas valve error - M COOL Cool Fan OFF Delay - 0 seconds OFF — Period E-COM - Green: indicates EnviraCOM™ bus activity gas valve. 10 7 4 1 WIRING CONNECTIONS a - Ignition Activation = 1 second Straight Spade 24 VAC Transformer - 24 Vac sequence - Flame still present the limit circuit opening or the Pressure HUM Humidifier Vac output Check/Repair: Low line voltage; Fuse Block Fuse Fuse - Automotive Type -120 3.0 Amps limit remained open longer than Repair:switch Remove Increase airflow Fixed Parameter Flashreplace Code Descriptions: Flash welded (Control rest Cool Fan OFF Delay - 60 seconds ONSetting Heat Fan ON Delay - 30Recognition seconds Period Red LED Status Code 2 +restrictions. 6 restrictions. Soft Lockout - airflow Gas Valve Failed Straight Spade 24 VAC - 24 Vac MOUNTING HOLE (X2) - Flame Quick Connect OFF= 3 seconds OFF All other conditions NotAApplicable ATransformer manual reset is required due to RolloutBOARD CLIPS 87(X6) PLASTIC Display/Diagnostics/EnviraLNK®/TAM limit remained open disconnected longer than orthrough Repair: Increase wiring loose; hose leaking;Remove MOUNTING TRAY The fieldMounting settings can be changed whenever necessary. The change three minutes furnace (increase motor speed, Cool Fan OFF Delay - 60 secondsto ON a Pulse: 0.25 second flash followed by 3.75 seconds of off time. error recovers and i Fig. 1. Typical Orientation showing wiring connections the COM Transformer Common to Make Quick Connect OFF All other conditions Not Applicable This is the default setting. PARK Circulator Motor Code and Error Description Check / Repair PLASTIC MOUNTING TRAY Park 120 Vac Input See “Troubleshooting” on page 19 for information about specific flash Limit three minutes through furnace (increase motor speed, Table 3. Wiring Connections (Class 2, Low Voltage). water in hose; venting blocked or obstructed. Automation and Control Solutions Failure Response Time 2 seconds (maximum) open more ducts, add more returns). M24908 next Flame takes effect for the situations which are being influenced by that Heat Fan ON Delay 60 seconds ON been detected five t S9200U1000 COM Transformer - Common Table 4. Wiring Connections (Class 1, Line Voltage). 1 4 open more ducts, add more returns). M24908 codes as in the checkoutOFF procedures.ON - Heartbeat: Constant 0.5 second bright 0.5 second dim cycles. PARK PARK HUM a referenced change. If for example a particular delay is in -progress and settings2are Fuse Block Fuse - Automotive Typeis- 3.0 Ampsdue to gas valve Codes a Descriptions: Flash Code - Periodic Blink:3 0.5 second on, Switch 0.5 During localIf history this fault PARK Circulator Motor Park 120 Vac Input A manual reset required 124 Display/Diagnostics/EnviraLNK®/TAM Heat Fan ONTime Delay 30 secondsLimitée OFF 2 + 1second - Exceed maximum Check/Repair: Gas supplyGas (pressure, supply, Pressure failed Closed Check: inducer isrecall, off; Failed inducer relay (K4) could HSI Igniter Warm-up Time = 17/27 seconds Fault De-bouncing seconds a Flash 2 +Soft 6off.Lockout Soft Lockout - Gas Valve Check/Repair: valve,3 Gas valveOther wiring. Honeywell Limitée Honeywell International Inc. Honeywell Limited-Honeywell ConnectionFuse + 5 Control failed Self Che Fuse Block Fuse Fusewelded - Automotive Type 3.0 Amps Code Descriptions: Connection changed, the current delay setting is Fan notON influenced by that change. The OFF Heat Delay - 30 seconds A 0.25 second flash followed by integrated 3.75 secondsfurnace off time.as a 1 + 2 pattern. condition being detected more times Fig. 1. Typical Mounting Orientation showing wiring connections to the retries shut-off valves, gas valve); ignition (HSI element 2 + 6 number SoftofLockout - GasbeValve Failed Check/Repair: valve, Gas wiring. isofflashed welded. TrialUse For Ignition = 6 seconds to Make Replace S9200U1000 if problem persists. the- Pulse: following procedures only for the error, or restarts failed hardwa 3and + 1Gas 24Vvalve (Control if the Terminal TypeTable (see Fig. 4) Connections Connects S9200U1000 to: Straight Spade 120Typical Vac InputS9200U1000 Neutral, Transformer Electronic COOL FANNorth OFF DELAY - Pulse: 0.25 second flash followed by 3.75 seconds of off control; time. Heat Fan OFF Delay - 120Activation seconds- Heartbeat: OFF OFF Heat FanCycle ON Delay seconds changes to5 minutes ON 1985 Douglas Drive 35 Dynamic Drive 1. Mounting Orientation showing wiring connections to field settings arethe not considered safety critical therefore, allowed maximum Compressor Short Delay- 60 S9200U1000 notwiring properly positioned glowing);Low to Make Replace S9200U1000 if flame problem persists. Terminal Type (see Fig. 4)Neutrals Fig.Connects to: Neutral, 4. Wiring (Class 1, Linethan Voltage). Constant 0.5 second bright second dim cycles. Check/Repair: Terminal (shorted); b - Ignition Period =component 3A seconds restarts if the error r see individual instructions for 0.5 additional checkout During local history recall, this fault is flashed as a 1 + 2 pattern. error recovers) Heat Fantime ON Delay - 60 seconds ON Connect Air Cleaner Neutral, CirculatorS9200U1000 Neutral, Humidifier -Period Heartbeat: Constant 0.5 on, second bright 0.5 second dim cycles. Table 4. Wiring Connections (Class 1, LineQuick Voltage). sensing (lead-wire broken or grounded, flame Other Codes pressure switch contacts (closed when should Flame Recognition = 3 seconds these parameters can be made at any during and after installation. Periodic Blink: 0.5 second 0.5 second off. During local history recall, this fault This covers hardware 6-position screw D/1 (optional) EnviraCOM™ Data Connection (if used) 1V 4Z9 Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 procedures. Heat Fan OFF Delay 180 seconds OFF ON Neutral Flame current caution level while running 4 Display/Diagnostics False Flame Recognition Period 20 seconds Other Codes 4-pin connector • IgniterSee Table 3 on page 8 not properly positioned, or flame rod Connection be open); pressure switchrod hoses have water - Periodic Blink: this fault is flashed as a 1 0.5 + 2 second pattern.on, 0.5 second off. During local history recall,Table flame sense circuit f terminal 9. Control Codes 3 + 1StatusLow 24V (Control restarts if the contamination); Check/Repair: Connection HSI Igniter Warm-up Timeis= flashed 30/30 seconds ON OFF (male terminals) Inducer lowLow linevoltage voltage.transformer and shorts, etc. build-up or obstruction. COOL FAN OFF DELAY S2 NOTE:HEAT FAN SeeON “DIPDELAY Switch S1 - FieldHeat Settings” on page Fan OFF Delay11. - 120 seconds customer.honeywell.com as a 1 + 2 pattern. 24 volt ground Terminal Type C/3(see Fig. 4) Connects S9200U1000 to: (#5 screw) OFF DelayOFF - 90 For secondsb = 6 seconds ON OFF as a 1 + 2 pattern. Heat Cycles to Safety Selection 10 cycles Heat FanOFF 3+1 Low 24V restarts if the Check/Repair: Low voltage transformer and NOTE: AnyOFF connector can be used. local history this fault is flashed error(Control recovers) circuit. Trial COOL FAN DELAY Harness HeatTimings Fan OFF Delay -Lock 120 seconds OFF OFF IgnitionDuring Tablerecall, 8. Flame status Codes Terminal Type (see Fig. 4) Connects S9200U1000 to: b During local history recall, this fault is flashed as a Flash 1 + 2 pattern. TEST MODE 8 Connector error recovers) 2 Code + 3 opened during Soft Lockout - Exceeded Check/Repair: wiring; 4 Pressure Switch Check: See if inducer is running. Pressure switchcircuit. - Ignition Heat Fan which OFF Delay - 180not seconds ON Red LED Status 24 volt hotSee - Thermostat 3 + 6slow Reversed Line Voltage Fixed parameters are those settings may be adjusted at any Heat FanOFF OFF Delay - 60 Activation seconds Period = 3 seconds ON ON 4-pin connector •R/2IgniterTable 3 on page S1 current limited) Straight Spade Flame Flame Sense - Signal Input (90 Vac, maximum of recyclesRestricted or inducer; restricted, or obstructed Voltage be nominally 24 Vac with 120 Vac Heat Fan OFF Delay - 180 seconds OFF- FlameON Trial For Ignition or Run Mode number Check/Repair: venting; low should inputexcessive, Recognition = 3 seconds HEAT FAN ON DELAY TableCode 9. Control Status Codes a Flash PeriodAmber 4-pin connector Inducer • IgniterSee Table 3 on page 8 is equipped with a Test Mode Poor (male terminals) /water Repair LED Status time. Switch (S1Heat and Quick Connect The S9200U1000 feature which allows Voltage should bevoltage. nominally 24 Vac 120 Earth Vac Ground Straight COOL Circulator cool speed output FanS2) OFFsettings Delay - 90 seconds ON OFF the last recycle/ venting; unstable line voltage.Verify on incoming line low with voltage HEAT FAN ON DELAY HEAT FAN OFFDIP DELAY voltage; in horizontal vent length. Table 9. Control Status Code Codes and Error Description retries whereCheck Thermostat Heat InputSpade (male terminals) WHarness Inducer a restarts if the error Heat Fan OFF Delay 90 seconds ON OFF on incoming line voltage. Verify low voltage and Error Description Check / Repair Code HSI Igniter Warm-up Time = 30/30 seconds ON ON The following field and safety parameters may be set using DIP Quick Connect retry was due to the pressure under all thermostat request modes to insure Flash the control to test andEAC verify several Harness DIP Switch S2 – Safety Timings within 5 Connector Pulse Control powered (Standby; No Not Applicable 3 + 2 Bad Fuse E-COM critical parameters. During Test Red LED Status Code Heat Fan OFF Delay 60 seconds ON two ON Electronic Air Cleaner 120 Vac Output under allissues thermostat request modes toloads insureminutes afte Limit Code Trial For Ignition = 8Flash seconds G Connector Thermostat continuous fan input switch opening there are no with other low voltage Table Fixed Parameters switches S15.and S2. Refer to-Fig. 4 on page 9 for the location Table of the a has Red LED Status Code 7. DIP Switch settings - Safety timings Mode, the S9200U1000 alters the selected Safety Timings as described Heat Fan OFFS1 Delay - 60 seconds ON ON OFF(S2) poweredflame Not ApplicableCheck (normal operation) there as arethe nooutdoor issues with voltage loads cleared ErrorNoDescription / Repair Call for Heat) Code - Ignition Activation Period = 5Control seconds such unit other 24 Vaclow contactor. a and DIP switch blocks. Straight Spade COOL Circulator cool speed output HEAT FAN Circulator heatOFF speedDELAY output 5 Limit2 switch Check: Wiring; restricted airflow through heat and Error Description Check / Repair Code cooling contactor output for HEAT + 4 open Soft Not Lockout - Exceeded Check/Repair: Gas supply; sensor wiring. such as the flame outdoor unit 24 Vac contactor. - Flame Recognition Period = 3 seconds Fixed Parameter Setting L1 in Table Straight Spade Y COOLThermostat cool input /Circulator cool14. speed output HEAT FAN OFF DELAY Quick Connect Heartbeat Call for Heat Normal operation Applicable (normal operation) Individual Switches Heartbeat PulseControl poweredCall for (Standby; heat operation) DIPTable Switch – Switch Safety Timings exchanger; clogged fan (limit, rollout, pressure switch EnviraCOM thermostats Control powered No Not Applicable (normal Not Applicable 3 + maximum 2 Fuse filters; slow circulator Check: Wiring number ofBad recycles EAC Electronic Air Cleaner 120 Vac Output CONT Quick Connect 6. S2 DIP (S1) settings - Field settings. XFMR Continuous circulation DIP Switch S27. – DIP Safety Timings M24909 Flame present Pulse Control powered (Standby; No Not Applicable 3 + 2 the last recycle was Bad Fuse Check: Wiring (limit, rollout,bus); pressure switch Call for Heat) where due tospeed. shorted to chassis; EnviraCOM gas valve Table Switch (S2) settings - Safetya timings ® U.S. Trademark Pre-Purge 30 seconds EAC Electronic Air Cleaner 120 Vac Output S1Registered Pressure Switch Codes The shorter of S2 the Descriptions two periods listed (17 seconds)Call applies to theSW2 first trial only, DIP Switch SW1 CONT Polarized 3-pin E-COM HEAT EnviraCOM™ diagnostic or communications device for Heat) shorted to chassis; Table 7. DIP Switch (S2) settings Safety timings a flame failure could beEnviraCOM shorted. bus); gas valve S1 Circulator heat speed output Individual Switches © 2007 Honeywell International Inc. XFMR Transformer 120 Vac Output Periodic Blink Call for heat Low flame current Check: Flame rod for contamination or loose connector Heartbeat Call for Heat Normal operation Not Applicable (normal operation) while the longer period (27 seconds) applies to the subsequent trials during the could be shorted. Individual Switches Repair: Remove restrictions. Increase airflow Fig. 2. DIP Switch (S1) Shown with factory default settings; all off Inter-trial Purge 60 seconds HEAT HEAT Circulator heat speed output Turn off the power and replace the fuse with a 2 Pressure Switch failed Open Check: If inducer is running, inducer could be FUSE 69-2087 69-2087 69-2087 J.Z. 08-07 a Heartbeat b OFF OFF wiring;Not low Applicable gas pressure. Call for Heat - Normal operation (normal operation) Individual Switches 2+5 Soft or Lockout - Exceeded Check: restricted airflow through heat Turn off the replace the fuse with a through furnace (increase motor speed, open HSI Igniter Warm-up Time = 17/27 seconds CONT Continuous circulation same call for heat. fusepower of theand same type. M24909 broken disconnected, or inducer relay K4 Wiring; may EAC L1 Line 120 Vac hot power supply24 VAC DIP Switch S1 Descriptions 15 seconds SW1 SW2 SW3 SW4 12-pin connector Main Harness CONT See Table 2Continuous on page 7. circulation Pressure Switch Codes Postpurge maximum numberhave of recycles exchanger; clogged filters; slow fuse of thecirculator same type. more ducts, add more returns). NOTE: FIELD SETTINGS (Page 11) Trial ForSW2 Ignition = 4 seconds M24909 Cycle power and run heating DIP Switch S2 Descriptions SW1 failed. 3to+appliance 4 appliance Gas valve error - Miswire or Pressure Switch Codes ConnectorXFMR Heartbeat Call for heat - Flame sense out of Check/Repair: Flame at burners, if present Transformer 120 Vac Output where the last recycle was due to fan speed. Cycle power to and run heating LED INDICATORS DIP Switch S2 Descriptions SW1 SW2 Ignition Activation Period = 1 second sequence. HUM Humidifier 120 Vac output Check/Repair: Low line voltage; Pressure switch Fig. 2. DIP Switch (S1) Shown with factory default settings; all off COM69-2087 FLAME COOL Cool Fan OFF Delay - 0 seconds OFF 10 7 4 1 69-2087 8 9 2 sequencePressure failed Open Check: If inducer running, inducer could be Flame Code the limit circuit opening or the welded (Control restarts if the Cool Fan ON Delay 5 seconds XFMR Transformer 120 Vac Output - Flame Switch still present replace gas is valve. a sequence. - Flame Recognition = 3 seconds OFF OFF Period If this failure repeats, replace therecovers control. Hard Fig. 2. DIP Switch (S1) Shown with factory default settings; can all off wiring loose; hose disconnected or leaking; The field settings be changed whenever necessary. The change HSI Igniter Warm-up Time = 17/27 seconds 2 Pressure Switch failed Open Check: If inducer is running, inducer could be The S9200U1000 provides three indicating LEDs (See Fig. 4 on page 9 Straight Spade 24 VAC L1 Transformer 24 Vac broken or disconnected, or inducer relay K4 may error and itLockout has not C Line 120 Vac hot power supply a seconds limit remained open longer than or obstructed. Repair: Remove restrictions. Increase airflowthe control. OFF This is the OFF If this failure repeats, replace default setting. PARK Motor Park 120 Vac 11) Input HSI being Igniter Warm-up Time 17/27 Fan OFFare Delay - 60For seconds ON water in hose; venting blocked NOTE:PLASTICCirculator FIELD SETTINGS (Page Trial Ignition = 4 seconds brokenNot or disconnected, or6inducer relay K4 may flame - Waiting takes effect for the next situations influenced by that Ignition RetriesCoolwhich 2 retries (3= retires total) Quick Connect have failed. beenwiring. detected five times yet) L1 Line 120 Vac hot power supply Unexpected Check/Repair: Gasorvalve leakage. OFF All other conditions Applicable for location on board): TRAY through furnace (increase motor 3 + 4 for three Gasminutes valve error - Miswire Check/Repair: Gas speed, valve NOTE: MOUNTING FIELD SETTINGS (Page 11) Trial For Ignition =settings 4=seconds - in Ignition Activation Period 1 second COM HUM Transformer - Common have failed. Humidifier 120 Vac output Check/Repair: Low line voltage; Pressure switch change. If for example a particular delay is progress and are flame to be off after the 20 + 4 If inducer Gasis valve error - Miswire or Check/Repair: Gasand valve OFF ON PARK Circulator Motor Park 120 Vac Input open more ducts, add returns). welded (Control restarts if the Cycle power appliance runwiring. heating M24908 3 disconnected Pressure Switchswitch failed Closed 3Check: off; inducer relay (K4) could HSI Igniter Warm-up Time = 17/27a seconds - Ignition Activation Period 1 second - Flame Recognition Period 3=seconds Ignition Recycles (4=cycles total) 3to+more Control Self Check, internal HUM Humidifier 120 Vac output Check/Repair: Low line voltage; Pressure wiring loose; hose or leaking; The field settings can be changed whenever changed, necessary. The change second delay — Trial Flame indicates flame status the current delay setting is not influenced by3 recycles that change. The welded Cycle power to5 appliance andfailed run heating a- Amber: error recovers and restarts it has notif the sequence. be(Control welded. For Ignition =Flash 6 seconds - Flame Recognition = 3 seconds Fuse Block Fuse PARK Fuse - Automotive Type -Park 3.0Spade Amps Code Descriptions: is the defaultPeriod setting. Circulator Motor 120 Vac Input Neutrals error, or failed hardware (Control wiring loose; hose disconnected or leaking; 2 + 6 The field can situations be Neutral, changed whenever necessary. Thenot change Heat Fan ON Delay -This 30 seconds OFF water in hose; venting blocked or obstructed. Straight 120 Vac Input settings Neutral, Electronic Soft Check/Repair: Lockout - error Gas Valve Failed Check/Repair: Gas valve, Gassequence. valve wiring. takes effect for theTransformer next which are field being influenced by that recovers and it (shorted); has not — Status Red: indicates general system status and error been detected fivewiring times yet) If this failure repeats, replace the control. settings are considered safety critical therefore, changes to Terminal Ignition Activation Period = 3 seconds This is the default setting. Auto Restart Delay 1 hour PARK CirculatorQuick MotorConnect Park 120 Vac Input restartsthe if the error recovers.) hose; venting blocked or obstructed. - Pulse: A 0.25 second flash followed by 3.75 seconds water of offintime. Soft Lockout Codes Fig. change. 1. takes Typical Mounting Orientation showing wiring connections to the effect for the next situations which are being influenced by that Air Cleaner Neutral, Circulator Neutral, Humidifier to Make Replace S9200U1000 if problem persists. been detected five times yet) If this failure repeats, replace control. If for example a particular delay is in progress and settings are a seconds codes. pressure switch contacts (closed when should - Flame Recognition Period = 3 seconds these parameters can be made Heat at any time during and Time after= 17/27 installation. OFF ON - Heartbeat: PARK Park 120 Vac Input Fan ON Delay - 60Warm-up seconds ON 3 Pressure Switch failed0.5 Closed If inducer is off; inducer relay (K4) could This covers hardware errors like HSI Igniter S9200U1000 Constant 0.5 second bright secondCheck: dim cycles. Table 4. Wiring Connections (ClassCirculator 1,Circulator LineMotor Voltage). Neutral 3 + 5be open); Control failed switch Self Check, run heating change.the If for example a particular delay is in progress settings are OFF ON pressure hosesinternal have water Cycle power to appliance and PARK Motor Park 120 Vac Input changed, current delay setting is not influenced by thatand change. The 3 Pressure Switch failed Closed Check: If inducer iswelded. off; inducer relay (K4) could HSI Igniter Warm-up = 17/27a seconds berecall, flame sense circuit faults, pin Trial For Ignition Time = 6 seconds Other Codes 3 + 5 Control failed Self Check, internal Cycle power to appliance and run heating error, or failed hardware (Control sequence. If this failure repeats, replace the Periodic Blink: 0.5 second on, 0.5 second off. During local history this fault HSI Igniter Warm-up Time = 30/30 seconds ON OFF changed, the current delay setting is not influenced by that change. The Straight Spade Neutrals 120 Vac Input Neutral, Transformer Neutral, Electronic build-up or obstruction. NOTE: “DIP Switch 11. Trial be welded. field settings Any areconnector not considered critical therefore, See changes to S1 - Field Settings” on page For Ignition = 6=seconds Check/Repair: Terminal wiring (shorted); shorts, the etc. - Ignition Activation Period 3 seconds error, orif failed hardware (Control sequence. If thiscontrol. failure repeats, replace Connection NOTE: can be used. safety restarts the error recovers.) Straight Spade Neutrals 120Cleaner Vac Input Neutral, Transformer Neutral, Electronic Trial For Ignition =is6flashed seconds as a 1 + 24pattern. Quick Connect Air Neutral, Circulator Neutral, Humidifier 2 are 69-2087 69-2087 3 - Flame 69-2087 69-2087 5 (Control field settings not be considered safety critical therefore, to Check/Repair: Terminal wiring (shorted); - Ignition Activation Period 3 seconds pressure switch contacts (closed when should 3 + during 1 Low 24V restarts iferror theiserrors Check/Repair: Low voltage transformer and Recognition Period = 3= seconds these parameters can made at any time during and afterchanges installation. restarts if the recovers.) control. COOL FAN OFF DELAY Heat Fan OFF Delay 120 seconds OFF OFF This covers hardware like 4 Pressure Switch opened Check: See if inducer running. Quick Connect Air Cleaner Neutral, Circulator Neutral, Humidifier Ignition Activation Period = 3 seconds Terminal Type (see Fig. 4) Connects S9200U1000 to: b Neutral 3+6 Reversed Line Voltage Polarity or parameters are those settings which may not be adjusted any switch contacts (closed when should - Flame Recognition Period =at 3 seconds these parameters can at any timeFixed during and after installation. During local history recall, this fault is flashed as a be 1pressure + 2 pattern. open); pressure switch hoses have water error recovers) circuit. Straight Spade Flame Flame Sense - Signal Input (90 be Vac,made current limited) This covers hardware errors flame sense circuit faults, pin Trial For Ignition or Run Mode Check/Repair: Restricted venting; low like input Neutral Recognition Period = 3 seconds Poor Earth Ground (Control Igniter Warm-up ON- Flame be open); pressure switch hoses have water build-up or obstruction. time. NOTE: See “DIP Switch S1 - Field Settings” on page 11. Heat Fan OFFHSI Delay - 180 secondsTime = 30/30 seconds OFF ON OFF Quick flame in sense circuit faults, pin shorts, etc. vent 4-pin connector • Igniter3 onconnector page Connect 8 can be used. voltage; water horizontal length. NOTE:See TableAny HSI Trial Igniter = 30/30 seconds ON OFF restarts ForWarm-up Ignition =Time 6 seconds build-up or obstruction. NOTE: See “DIP Switch S1 - Field Settings” on page 11. Voltage should be nominally 24 Vac with 120 Vac if the error recovers HEAT FAN ON DELAY Table 9. Control Status Codes shorts, etc. HSI Igniter Warm-up Time = 30/30 seconds ONopened duringON (male terminals) Inducer NOTE: Any connector can be used. Trial For Ignition = 6 seconds 4 Pressure Switch Check: See if inducer is running. within Ignition Activation Period = 3 seconds Heat FanParameters OFF Delay - 90 seconds ON OFFFor Ignition = 8 seconds onorincoming line voltage. Verify low voltage5 minutes after the fault 3+6 Reversed Line Voltage Polarity Check: Fixed parameters are those settings which may not be adjusted at Table any 5. Fixed Limit Code Trial Harness Flame Straight Spade Flame Sense - Signal Input (90 Vac, current limited) 4 Pressure Switch during Check/Repair: Check:Restricted See if inducer is running. - Ignition Activation Period = seconds 3 seconds Trial For Ignition or opened Run Mode venting; low input has cleared.) Flame Recognition Period = 3 under all thermostat request modes to insure 3 + 6 Reversed Line Voltage Polarity or Check: Fixed parameters are those settings which may not be adjusted at any Poor Earth Ground (Control 1. Line voltage input wiring. Assure Flash Straight Spade Flame Flame Sense - Signal Input (90 Vac, current limited) time. Connector Quick Connect Red LED Trial Status Codeor Run Mode voltage; For Ignition Check/Repair: low inputopen - Flame Recognition Period = 3 seconds Heat Fan OFF Delay - 60 seconds ON - Ignition ONActivation Period = 5 seconds water5inRestricted horizontalventing; ventLimit length. there areheat noline issues withvoltage other voltage loads Assure Poor Ground (Control 1. Line input switch Check: Wiring; restricted airflow through restarts ifEarth the error recovers voltage hotlow lead iswiring. attached to time. Quick Connect = 3a seconds Fixed Parameter Setting voltage; water in horizontal vent length. HSI Igniter Warm-up Time = 30/30 seconds ON- Flame Recognition ON Period and Error Description Check / Repair Code such as the outdoor unit 24 Vac contactor. restarts if the error recovers line voltage hot lead is attached to exchanger; clogged filters; slow circulator fan within 5 minutes after the fault L1. Straight Spade COOL Circulator cool speed output HEAT FAN OFF DELAY HSI Trial Igniter = 30/30 seconds ON ON Limit Code ForWarm-up Ignition =Time 8 seconds Table 5. Fixed Parameters withinhas 5 speed. minutes after the fault 2. Ground wire from control L1. to appliance and cleared.) Quick Connect Pre-Purge 30 seconds Limit Code Trial For Ignition = 8 seconds a Table 5. Fixed Parameters - IgnitionTimings Activation Period = 5 seconds DIP Switch S2 – Safety Control powered (Standby; Not Applicable 3+2 Bad Fuse has cleared.) Check: Wiring (limit, rollout, pressure switch The shorter of the two periodsPulse listed (17 seconds) applies to theNo first trial only, 2. Ground wire from control to appliance and EAC Electronic Air Cleaner 120 Vac Output appliance earth ground. 5 open Check: Wiring; restricted airflow through heat - Ignition Activation Period 5 seconds Recognition Period = 3= seconds Fixed Parameter SettingInter-trial Purge Call for Limit Heat)switchtrials shorted to chassis; EnviraCOM bus); gasground. valve and Table 7.- Flame DIP Switch (S2) settings - Safetywhile timings S1 appliance earth the longer period (27 seconds) applies during the Repair: Remove restrictions. Increase airflow 3. Voltage between line volt Neutral 60 seconds 5 to the subsequent Limit switch open Check: Wiring; restricted airflow throughfan heat exchanger; clogged filters; slow circulator - Flame Recognition Period = 3 seconds Fixed Parameter Setting could be shorted. HEAT Circulator heat speed output 3. Voltage between volt Neutral through furnace (increase motor speed, openappliance chassis. If overline 10 volts, repair and the same callSwitches for heat. exchanger; clogged filters; slow circulator fan speed. Heartbeat Call for Heat Normal operation Not Applicable (normal operation) Individual Pre-Purge 30 seconds Postpurge Turn off the power and replace the fuse with acircuit a chassis. If over 10 volts, repair the 15 seconds more ducts, add more returns). wiringappliance or move the furnace to another with The shorter of the two periods listed (17 seconds) applies to the first trial only, speed. Pre-Purge 30 seconds a The shorter of the two periods listed (17 seconds) applies to the first trial only, CONT Continuous circulation fuse oforthe same type. M24909 wiring move the furnace to another circuit with LED INDICATORS a good earth ground. while the longerS2 period (27 seconds) applies to the SW1 subsequent trials during the Pressure Switch Codes Repair: Remove restrictions. IncreaseFlame airflow Inter-trial Purge 60 seconds Cycle power to appliance and run heating DIP Switch Descriptions SW2 Cool Fan ON Delay 5 seconds Code a good earth ground. while the longer period (27 seconds) applies to the subsequent trials during the Repair: Remove restrictions. Increase airflow Inter-trial Purge 60 seconds through furnace (increase motor speed, open same call for heat. XFMR Transformer 120 Vac Output Hard Lockout Codes The S9200U1000 provides three indicating LEDs (See Fig. 4 on page 9 sequence. Fig. 2. DIP SwitchPostpurge (S1) Shown with factory default settings; all off Repair: Reverse line voltage inputs if line volt hot 2 Pressure Switch failed Open Check: If inducer is running, inducer could be speed, open through furnace motor 15 secondsIgnition Retries same call for2heat. more ducts, add more returns). a total) retires OFF OFF 6 (increase Unexpected flame - Waiting for Check/Repair: Gas valve leakage. If this failure repeats, thetocontrol. for location on board): Repair: Reverse line voltage if line volt hot HSI INDICATORS Igniter Warm-upretries Time =(317/27 seconds lead is notreplace attached theinputs L1 input. Postpurge 15 seconds broken or disconnected, or inducer relay K4 may more ducts, add more returns). L1 Line 120 Vac hot power supply LED flame to be off after the 20 lead is not attached to the L1 input. NOTE: FIELD SETTINGS (Page 11) Trial For Ignition = 4 (4 seconds Cool Fan ON Delay 5 seconds have failed. Flame Code LED INDICATORS Ignition Recycles 3 recycles cycles total) 3 + 4 Gas valve error Miswire or Check/Repair: Gas valve wiring. second delay — Flame Amber: indicates flame status Hard Lockout Codes The S9200U1000 three indicating LEDs (See Fig. 4 on page 9 - Ignition Activation provides Period = 1 second Cool Fan ON Delay 5 seconds Flame CodeCheck/Repair: Low line voltage; Pressure switch HUM Humidifier 120 Vac output welded (Control restarts if the CodesCycle power to appliance and run heating Hard Lockout S9200U1000 provides three indicating LEDs Fig. 4- Red: on page 9 — (See Status indicates general system status error Ignition Retries 2 retries (3 retires - Flame Recognition Period = 3 seconds 6 Unexpected flame and - Waiting for loose; hose Check/Repair: Gasorvalve leakage. forThe location on board): wiring disconnected leaking; The field settings can be changed whenever necessary. The change Autototal) Restart Delay 1 hour Lockout Codes error recovers and it has not sequence. Ignition Retries 2 retries (3 retires total) 6 Unexpected Waiting Check/Repair: valveSoft leakage. This is the setting. for location ondefault board): PARK Circulator Motor Park 120 Vac Input flame to be offflame after -the 20 codes. waterforin hose; venting blocked orGas obstructed. takes effect for the Ignition next situations which are being influenced by that been detected five times yet) If this failure repeats, replace the control. Recycles 3 recycles (4 cycles total) flame to be delay off after the 20 second — Flame Amber: indicates flame status change. If for example a particular delay is in progress and settings are Ignition Recycles 3 recycles (4 cycles total) a OFF ON PARK Circulator Motor Park 120 Vac Input second — Status Flame - Amber: indicates flame statusstatus and error 3 Pressure Switch failed CloseddelayCheck: If inducer is off; inducer relay (K4) could HSI— Igniter Warm-up Time = 17/27 seconds - Red: indicates general system 3+5 Control failed Self Check, internal Cycle power to appliance and run heating Autodelay Restart setting Delay is not influenced by that change. 1 hour changed, the2 current Soft Lockout Codes 69-2087 be welded. For Ignition =- 6Red: seconds —Trialcodes. Status indicates general system status and error 69-2087 69-2087 1 hour The 3 4 69-2087 5 error, or failed hardware (Control sequence. If this failure repeats, replace the Restart Delay Straight Spade Neutrals 120 Vac Input Neutral, Transformer Neutral, Electronic Soft Lockout Codes Check/Repair: Terminal wiring (shorted); field settings are notAuto considered safety critical therefore, changes to - Ignition Activation Period = 3 seconds codes. restarts if the error recovers.) control. Quick Connect Air Cleaner Neutral, Circulator Neutral, Humidifier pressure switch contacts (closed when should - Flame Recognition Period = 3 seconds these parameters can be made at any time during and after installation. This covers hardware errors like Neutral be open); pressure switch hoses have water flame sense circuit faults, pin 2 69-2087 69-2087 3 69-2087 5 6 69-2087 HSI Igniter Warm-up Time = 30/30 seconds 4 4 ON OFF 69-2087 NOTE: See “DIP Switch S1 - Field Settings” on page shorts, etc. 2 connector can be used. 69-2087 69-2087 3 11. 69-2087 69-2087 5 build-up or obstruction. 6 69-2087 NOTE: Any Trial For Ignition = 6 seconds 16_Troubleshooting_p295.indd 252-253 3/24/08 4:30:16 PM 4 Pressure Switch opened during Check: See if inducer is running. Ignition Activation Period = 3 seconds 3+6 Reversed Line Voltage Polarity or Check: Fixed parameters are those settings which may not be adjusted at any
E-COM
4
Polarized 3-pin connector
16
3 4
S9200U1000 Universal Hot Surface Ignition Integrated Furnace Control (continued)
W
ON
G
TECHNICIAN’S QUICK REFERENCE GUIDE
12
ON
ON
D/1
NEUTRALS
1234
ON
C/3
LOCKOUT JUMPER
R/2
troubleshooting
2
Y
TECHNICIAN’S QUICK REFERENCE GUIDE
Technical Information
ON
1
S9200U1000 Universal Hot Surface Ignition Integrated Furnace Control
ON
16
Technical Information
FLAME
E-COM
STATUS
16
Y
technical information
G W
ON
ON
1
NEUTRALS
2
E-COM
FLAME
STATUS
3
E-COM
4
FLAME ON STATUS FLAME E-COM STATUS
NEUTRALS
ON
D/1
ON
1 2 3ON 4
1234
1 2ON
ON
12
ON
LOCKOUT JUMPER LOCKOUT JUMPER
D/1
D/1
C/3
C/3
R/2
R/2
W
1234
ON
W
C/3
G
LOCKOUT JUMPER
12
G
R/2
Y
NEUTRALS
Y
ON
1
G
ON
Y W
3
2
2
ON
D/1
NEUTRALS
2
1
1234
ON
ON ON
1
12
ON
C/3
LOCKOUT JUMPER
R/2
4
3
3
E-COM
FLAME
STATUS
ON
4
4
ON ON
ON
1 2 3 4
ON
252
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
253
Technical Information
SECTION
SECTION
16
16
Technical Information troubleshooting
S9200U1000 UNIVERSAL HOT SURFACE IGNITION INTEGRATED FURNACE CONTROL EGRATED FURNACE CONTROL S9200U1000 UNIVERSAL HOT SURFACE IGNITION INTEGRATED FURNACE CONTROL
S ModifiedHot Timing S9200U1000 Universal S Surface Ignition Integrated F Furnace Control (TAM). In addition to alarms, key information such as state and flame terminalQuickLook™ D/1. (TAM). In addition to alarms, key information such as the state and flamescrew-terminal R/2 to terminal D/1. 72 and the W8735D Telephone Access Modulecurrent 1. Jumper thermostat us activity TECHNICIAN’S QUICK REFERENCE GUIDE TECHNICIAN’S QUICK canREFERENCE be sent over theGUIDE EnviraCOM™ bus. See Table 13.Table 12. Test Mode Parameters Recalling the Status Code History OnWatch ENVIRACOM COMMUNICATIONS • Within 0.5 seconds, the redinformation status LEDsuch stops Flashthe red current sent over the EnviraCOM™ bus. See Table • Within 0.5 seconds, LED stops Flashcan be (TAM). In addition to alarms, key asnormal state and flame Redstatus LED Status Codenormal terminal D/1. 13. Red LED Status Code S9200U1000 Uni operation and turns on solid to indicate that the jumper is TECHNICIAN’S QUICK REFERENCE GUIDE You may perform the following procedure multiple times to confirm that and turns on solid to indicate that the jumper is Th current can be sent over the EnviraCOM™ bus. See Table 13. EnviraCOM™ communication is a standard feature on the • Within 0.5 seconds, the red status LED stops normal Code and Error Description Check / Repair out specificoperation flash This following service procedure provides a quick overview This following service procedure provides a quick overview for the Code for the and Error Check / Repair Table 11. S920001000 EnviraCOM Alarms Test Mode Parameter Modified Timing sensed. Table 11.Description S920001000 EnviraCOM Alarms have viewed all the currently stored error codes. sensed. S9 S9200U1000. EnviraCOM™ can be used to control system operation operation and turns on solidyou to indicate that the jumper is S9200U IFC. For more information, refer to form 69-2075. S9200U IFC. For more information, refer to form 69-2075. 2. Keep the thermostat screw-terminal R/2 to D/1 jumpered. This following service procedure provides a quick overview for the Surface Ignition 2. Keep the thermostat screw-terminal R/2 to D/1 jumpered. 11. S920001000 Alarms by of an EnviraCOM™ sensed. Alarm Alarm After ared 5 second time-out, theEnviraCOM redway status LED turns off, enabled thermostat and perform advanced To recall the error code history and display• it via theTable status LED, S9200U IFC. For more information, refer to form 69-2075. • After a 5 second time-out, the red status LED turns off, furnace control; diagnostics when connected to EnviraCOM™ enabled diagnostic Number tools 2. Keep the thermostat screw-terminal R/2the to following: D/1 jumpered. WI Alarm Description Comment WIRING HARNESSES indicating that error code recall is pending. perform Alarm Description Number Comment Alarm indicating WIRING that errorHARNESSES code recall is pending. checkout such as the web based EnviraLNK® remote diagnostics application, the • After a 5 second time-out, the red status LED turns off, Furnace Control WIRING HARNESSES Alarm Number Comment OnWatch QuickLook™ indicating that error code recall pending. Table 1. Table 1. 72 and the W8735D Telephone Access Module 1. isJumper the thermostat screw-terminal R/2 Description to
Recalling the Status Code History ENVIRACOM COMMUNICATIONS ENVIRACOM COMMUNICATIONS Flash Table 12. Test Mode Parameters Red LED Status Code S9200U1000 Universal Hot S9200U1000 HotTable 12.is aTest You may perform the following procedure multiple times to confirm that Universal Recalling the Status Code History ENVIRACOM COMMUNICATIONS EnviraCOM™ communication standard on the and Error Check / Repair Modefeature Parameters EnviraCOM™ communication is a Code standard feature on Description the Test Mode Parameter Modified you have viewed all the Timing currently stored error codes. S9200U1000. EnviraCOM™ can be used to control system operation You may perform the following procedure multiple times to confirm that S9200U1000. EnviraCOM™ can be used to control system operation EnviraCOM™ communication is a standard feature on the Code and Error Description Check / Repair Test Mode enabled Parameter Timing Surface Ignition Integrated Ignition Integrated by way of an EnviraCOM™ thermostat andModified perform advanced you have viewed all the advanced currently stored error codes. by way of an EnviraCOM™ enabled thermostat and perform To recall the error code history andcan display itSurface viatothe red status LED, S9200U1000. EnviraCOM™ be used control system operation diagnostics when connected to EnviraCOM™ enabled diagnostic tools o recall the error code history and display it via the red status LED, diagnostics when UNIVERSAL connected to EnviraCOM™ enabled diagnostic tools INTEGRATED FURNACE CONTROL S9200U1000 HOT SURFACE IGNITION perform the following: by way of an EnviraCOM™ enabled thermostat and perform advancedsuch as the web based EnviraLNK® remote diagnostics application, the erform the following: To recall the error code history and display it via the red status LED, such as the web based EnviraLNK® remote diagnostics application, the (continued) Furnace Control (continued) Furnace Control diagnostics when connected to EnviraCOM™ enabled diagnostic toolsOnWatch QuickLook™ 72 and the W8735D Telephone Access Module performTelephone the following: 1. such Jumper thermostat screw-terminal R/2diagnostics to OnWatch QuickLook™ 72 and the W8735D Access Module 1. Jumper the thermostat screw-terminal R/2 to as thethe web based EnviraLNK® remote application, the
Recalling the Status Code History
You may perform the following procedure multiple times to confirm that Flash ed Red LED Status Code ou Timing have viewed all the currently stored erroracodes.
a
Table 12. Test Mode Parameters
Test Mode Parameter
4+1 Hard Lockout - Rollout circuit Check/Repair: Flue restrictions; heat exchanger Pre-Purge 5 seconds Pre-Purge 5 seconds open or previously opened. restricted Check/Repair: Flue restrictions; heat exchanger HSI Warm-up 17 seconds Check burner. Check Rollout Switch Pre-Purge 5 seconds seconds HSIincluding Warm-up 17 seconds restricted switch cables. Ignition Activation 3 seconds HSI Warm-up 17 seconds Check burner. Check Rollout Switch including Reset rollout if necessary. econds Ignition Activation 3 seconds switch cables. Do not operate until repairs are made. Flame Recognition 1 second Ignition Activation 3 seconds Reset rollout if necessary. Cycle power to appliance andFlame run heating second Recognition 1 second Do not operate until repairs are made. sequence. a Trial for Ignition 4 seconds Flame Recognition 1 second a to appliance and run heating econds Trialcontrol. for Ignition 4 seconds Cycle power If this failure repeats, replace the sequence. Heat Fan ON Delay 15 seconds Trial for Ignition 4 seconds seconds Fan ON Delay 15 seconds +2 Hard Flue Lockout - Gas valve Check/Repair: Gas valveHeat wiring. If this4 +failure control.circuit 4 Check/Repair: 2+1 Soft Lockout - Exceed maximum Check/Repair: Gas supply (pressure, supply, 1 repeats, Hardreplace Lockoutthe- Rollout restrictions; heatwelded exchanger Pre-Purge 5 seconds relay detected for five times Cycle power to appliance and run heating number of retries shut-off valves, gas valve); ignition (HSI element Heat Fan OFF Delay 0 seconds open or previously opened. restricted Heat Fan ON Delay 15 seconds econds 0 seconds 4+2 Hard Lockout - Gasnot valve weldedpositioned and Check/Repair: Gas valve wiring. sequence. Heat Fan OFF Delay properly glowing); flame HSI Warm-up 17 seconds Check burner. Check Rollout Switch including relay detected for five times Cycle or power to appliance and run heating If this failure repeats, replace the control. sensing (lead-wire broken grounded, flame Post-Purge 5 seconds Heat Fan OFF Delay 0 seconds switch cables. econds Post-Purge 5 seconds Thisconnector device has no alarms 0 Not Applicable sequence. Main harness plugrodconnector Main harness plug 12-pin not properly 12-pin positioned,This or flame rodhas no alarms Ignition Activation 3 seconds device 0 NotifApplicable Reset rollout necessary. If low this line failure repeats, replace the control. a 3. Within 10 seconds of the red status (TAM). LED turning off, remove the Cool Fan ON Delay 2 seconds Post-Purge 5 seconds contamination); voltage. In addition to alarms, key information such as state and flame (Class 2, Low Voltage) . (Class 2, Low Voltage) . terminal D/1. 3. Within 10 seconds of the red status LED turning off, remove the Do not operate until repairs are made. econds Cool Fan ON Delay 2 seconds Table 1. Main harness plug connector 12-pin Code Descriptions: Pressure switch failed to close in the ignition 1 Display/Diagnostics This device has no alarms 0 Not Applicable Flame Recognition 1 second Pressure switch failed to close in the ignition Flash 1 Cycle thermostat current can be sent over the EnviraCOM™ bus. See Table 13. power to Display/Diagnostics appliance and run heating Withinoff, 0.5remove seconds, status LED screw-terminal stops normal R/2 to terminal thermostat screw-terminal sequence - Pulse: A second flash followed bythe 3.75red seconds off•time. 3.0.25 Within 10 seconds of statusofLED turning thethe red D/1 Cool Fan OFF Delay (Class 2, Low Voltage).0 seconds Cool Fan ON Delay 2 seconds Pin Function Pin # Function 2 + 3# R/2a to Softterminal Lockout - Exceeded Check/Repair: Pressure switch wiring; slow sequence econds D/1 jumper. Cool Fan OFF Delay 0 seconds jumper. sequence. Flash Code Descriptions: Pressure switch failed to close in the ignition 1 Display/Diagnostics that the jumper is Trial for Ignition 4 seconds maximum number of recycles or High inducer; excessive, or obstructed - Heartbeat: 0.5 second bright, 0.5 second cycles. operation and turns on solid to• indicate thermostat screw-terminal R/2 todim terminal This following service procedure pr 1 Limitrestricted, Out High Limitfailed Outto open If thisConstant failure repeats, replace the control. Pin # Function Thissequence activates the error code recall.1 Pressure switch in the Display/Diagnostics -code Pulse: A 0.25 second by 3.75 seconds of offfailed time. Cool Fanignition OFF Delay 3 0 seconds Table 11. S920001000 EnviraCOM Alarms • This activates the error retries recall. Pressure switch to open in the ignition - During 3 start-up Display/Diagnostics where the last recycle/flash followed venting; unstable line voltage. thejumper. STATUS LED blinks fast for approximately 2sensed. seconds. If the D/1 S9200U IFC. For more information sequence Heat Fan ON Delay 15 seconds 2 Flame Sense Flame (90 Vac, current 2 Flame Sense - Flame Signal Input (90 Vac, current limited) 1 High Limit Out - Heartbeat: 0.5Signal secondInput bright, 0.5 second cycles. k / Repair sequence retry was due toConstant the -pressure 2. Keep the thermostat screw-terminal R/2 to D/1 jumpered. 4 + 2dim limited) Hard Lockout - Gas valve welded Check/Repair: Gas valve wiring. S9200U1000 continues fast the (8 pulses/second), the control has failed and • Thisblinking activates error code recall. Pressure switch failed to open in the ignition 3 Display/Diagnostics Alarm IMPORTANT switch opening - During start-up the STATUS 2 detected seconds. the 3 24LED Vac blinks Hot fast for approximately 3 24 Vac switch Hot opened in run or trial • After a 5 second time-out, the red status LED turns off, MPORTANT relay forIffive times must be Cycle power to appliance and run heating 2 Flame Sense - Flame Signal Input (90 Vac, current limited) The pressure 98 Display/Diagnostics sequence replaced. Heat Fan OFF Delay 0 seconds The pressure the switch openedhas in run or trial 98 Display/Diagnostics e (normal operation) WIRING HARNESSES If the R/2 to D/1 terminal jumper is not removed within the Number Comment S9200U1000 continuesNot blinking fast (8 pulses/second), control failed and- Standard that pending. If the R/2 to D/12terminal jumper is not removed within forUsed more than the allowable time Usedthe (TBD) 4 Alarm Description Not (TBD) LED Fault sequence. Pattern (Single X Flash): LED flashes X timesindicating at 2HZ, then off error code recall10isseconds, 3 24 Vac Hot IMPORTANT for more than wiring. the allowable time +4 4 Soft Lockout - Exceeded Check/Repair: Gas supply; flame sensor thein history If this failure repeats, replace the control. The pressure switch opened run or trialwill be98erased. Display/Diagnostics must be replaced. Post-Purge 5 seconds 10 seconds, the history will be erased. e (normal operation) maximum number of recyclesRollout Switch Out Table 1. Main harnes for 3 seconds. If the R/2 to D/1 terminal jumper is not removed within the 5 5 Rollout Switch Out This device has no alarms 0 Not Applicable 4 Not Used (TBD) Limit switch open 26 Display/Diagnostics for more than the allowable time - Standard LED Fault Pattern (Single X Flash): LED flashes timesopen at 2HZ, then off- Advanced LimitXswitch 26 Display/Diagnostics where the last recycle was due to (Class 2, L LED Fault Pattern (X +the Y Flash): X Within times at10 2Hz, remainsof the red 10 seconds, historyLED willflashes be3.erased. seconds LED turning remove Cool Fan ON Delay 2 seconds 6 blinks once 24 LED, Vac Common a Flash Code Descriptions: 24 1Vac Common Display/Diagnostics 4.status Each saved erroroff, code blinksthe once on the6 red status LED, 5 Rollout Switch Out for 3aon seconds. flame failure 4. Each saved error code the red status Pressure switch failed to close in the ignition Flame detected out of sequence 34 Display/Diagnostics Limit switch open 26 Display/Diagnostics off for one second, flashes Y times at 2Hz, remains off for three seconds, and thermostat screw-terminal R/2 tostarting terminal Flame detected outat of sequence 34 Display/Diagnostics or contamination or loose with the most recently stored error Pin # High Limit In + Pressure Switch Out 7 code.sequence High Limit In + Pressure Switch Out LED Fault Pattern (X + Y Flash): flashes X times 2Hz, followed remains bythen 6 24 Vac Common -LED Pulse: A 0.25 second flash 3.75repeats. seconds of offsaved time. error code blinks once on D/1 starting with the most7recently- Advanced stored error code. Cool Fan OFF Delay 0 seconds 4. Each the red status LED, w gas pressure. jumper. 2+5 Soft Lockout ExceededflashesCheck: Wiring; restricted airflowoff through heat seconds, and Soft lockout due to flame current 5 Display/Diagnostics Flame detected out of sequence 34 Display/Diagnostics off for one -second, Y times at 2Hz, for three 1 -remains Heartbeat: Constant 0.5 second dim cycles. 8 Ground Softslow lockout due to flame current bright, 0.5 5 second starting Display/Diagnostics 8 switch Chassis Ground 7 High Limit In + Pressure Switch Out with the most recently stored error number of immediately recycles Chassis exchanger; filters; circulator • code. This activates the error NOTE: code recall. If there are no error codes to display, the red status LED immediately nor-ignition Pressure failed toreturns open intothe 3 Display/Diagnostics OTE: are no error codes to display,maximum the red repeats. status LED returns to nor- clogged During start-up the STATUS LED blinks fast for approximately 2 seconds. If the Status Codes Table 10. E-Com 2 Flame Sense - Flame me at burners, Ifif there present wherethen the last recycle was dueMain to Valve Common fan- speed. 9 9 Main operation. Soft Valve LockoutCommon due to recycle; last recycle 85 Display/Diagnostics sequence Softmal lockout due to flame current 5 Display/Diagnostics 8 Chassis Ground mal operation. Soft Lockout due to recycle; last recycle 85 Display/Diagnostics S9200U1000 continues blinking fast (8 pulses/second), has failed NOTE: If the therecontrol are no error codes toand display, the red status LED immediately returns to nore gas valve. the limit circuit opening or the was from pressure switch open 3 IMPORTANT 10 Pressure Switch In Statuswas 10 Pressure Switch InDisplay/Diagnostics from pressure switch open 9 Main Valve Common Table 10. E-Com Codes Green LED Status The pressure switch opened in run or trial 98 mal operation. Soft Lockout due to recycle; last recycle 85 Display/Diagnostics limit remained open longer than Repair: Remove restrictions. Increase airflow must be replaced. 5.jumper Afterislast error code within displays, the red status LED returns to norIf the R/2 to D/1 terminal notpressure removed 5. After last error code displays, the red to nor4 Applicable 11 Rolloutthrough Switch In (increase 11 Rollout Switch In of flame loss The maximum number 22 Display/Diagnostics for more than the allowable time wasoperation. from switch open the 10 Pressure Switch In threestatus minutesLED returns furnace motor speed, - Standard LED Fault X Flash): X times at 2HZ, Code and then off The maximum numberPattern of flame(Single loss 22 LED flashesDisplay/Diagnostics mal 10LED seconds, the mal operation. GreenMain LED Status incidents has been exceeded open more ducts, add returns). 5. After last error code adisplays, the red status returns to history nor- will be erased. 5 R 12 Valve 12 Main Valve incidents has been exceeded 11 Rollout Switch In for 3more seconds. Limit switch open 26 Display/Diagnostics The maximum number of flame loss 22 Display/Diagnostics Flash Code Check / Repair Description Code and mal operation. - Advanced LED Fault Pattern (X + Y Flash): LED flashes X times at 2Hz, remains 6 Soft Lockout due to recycle; last recycle 86 Display/Diagnostics exceeded 12 Main Valve 2+6 Soft Lockout - Gas Valve Failed Check/Repair: Gas valve wiring. 4. Each saved error code blinks once incidents on thehas redbeen status LED, Soft Lockout due to recycle; last recycle 86 Display/Diagnostics a Gas valve, Ign me. Flame detected out of sequence 34 Display/Diagnostics offif for one second, flashes for three was from limit switch open FlashtoCode Check Repair Description Make Replace S9200U1000 problem persists. Rapid remains Flashing off Bus Activityseconds, - Message and being Not Applicable (normalwith operation) Igniter/Inducer Harness Plug Connections Igniter/Inducer Harness Plug Connections 7 High Limit was from limit/ switch openY times at 2Hz, starting the most recently stored error Soft Lockout duecode. to recycle; last recycle 86 Display/Diagnostics s. then repeats. transmitted Igniter/Inducer Harness Plug Connections 8 SoftTable lockout 2. dueIgniter/Inducer to flame current 5 Gas plug Display/Diagnostics valve failed to energize 4-Pin 17 Display/Diagnostics/EnviraLNK®/TAM Table 2. Igniter/Inducer plug being Connector 4-Pin harness Connector was from limit switch open Other Codes Busharness Rapid Flashing Activity - Message NotGas Applicable (normal operation) story recall, this fault valve failed to energize 17 Display/Diagnostics/EnviraLNK®/TAM NOTE: If there are no error codes to display, the red status LED immediately returns to norBlink CodesBus Activity - Received Not Applicable (normal operation) transmitted 9 Connector 4-Pin Ma Table 2. Igniter/Inducer harness plug Table 10. E-ComSingle Status mal operation. Lockout last recycleLettering Low85voltage is detectedDisplay/Diagnostics on 24 Vac input 125 Display/Diagnostics/EnviraLNK®/TAM Gas valve failed to energize 17 Soft Display/Diagnostics/EnviraLNK®/TAM 3 + 1# Low 24VReference (Control restarts if the Check/Repair: Low voltage transformer and on Pin Lettering Function Pin # due to recycle; Reference Function message acknowledgment Low voltage is detected 24 Vac input 125 Display/Diagnostics/EnviraLNK®/TAM 10 P was from pressure switch open ttern. error Blink recovers) Single Bus Activity - Received circuit. Not Applicable (normal operation) Pin # Reference Lettering Function Green LED Status92 Off Display/Diagnostics/EnviraLNK®/TAM (NOTE: 92 Display/Diagnostics/EnviraLNK®/TAM Lowred voltage is detected 24 Vac input Display/Diagnostics/EnviraLNK®/TAM 5. Disconnect After last code displays, the status LEDonreturns to nor- 125 1 IND-HOTmessage acknowledgment Inducer 120has Vacbeen detected 1 IND-HOT A bad fuse has been detected Inducer 120This Vac No Bus Activity Check/Repair: the error S9200U1000 A bad fuse (NOTE: This 11 R The maximum number of flame loss 22 Display/Diagnostics alarm is stored in the Status Code History) Code and Voltage should be nominally within120 operation. from the external mal bus wiring, cycle power and alarm24 is Vac stored the Vac Status Code History) 1 IND-HOT Inducer 120 Vac 12 A bad fuse has been detected (NOTE: This 92 Display/Diagnostics/EnviraLNK®/TAM 2 Igniter 120 Vac 2incidents has been exceeded IGN-HOT Igniter 120 Vac Off IGN-HOT No Bus Check/Repair: on Activity incoming line voltage. Verify lowDisconnect voltage the S9200U1000 a check the bus activity. If there is activity, The gas valve relay was sensed as closed 100 Display/Diagnostics/EnviraLNK®/TAM alarm is stored in the Status Code History) Flash Code Check / Repair Description external wiring, cycleas power and The the gasmodes valve relay was sensed closed 100 Display/Diagnostics/EnviraLNK®/TAM repair external bus wiring/devices before under all thermostat from request tobus insure 2 IGN-HOT Igniter 120 Vac Soft Lockout due to recycle; last recycle 86 when it shouldDisplay/Diagnostics be Inducer open Neutral 3 IND-NEUTRAL Inducer 3 IND-NEUTRAL check the busitactivity. when should openis activity, there are no issues with other Neutral low voltage loadsIfbethere reconnecting the S9200U1000 back. Igniter/Inducer Harness Plug Conn was from limit switch open The gas valve relay was sensed as closed 100 Display/Diagnostics/EnviraLNK®/TAM Rapid Flashing Bus Activity - before Message being Not Applicable (normal operation) / Repair repair bus wiring/devices such as the outdoor unit 24 external Vac contactor. If there is still no activity, replace the control. 3 IND-NEUTRAL Inducer Neutral Electronics down 18 Display/Diagnostics/EnviraLNK®/TAM when it should be open 4 IGN-NEUTRAL Igniter Neutral 4 IGN-NEUTRAL Igniter Neutral Electronics down transmitted 18 Display/Diagnostics/EnviraLNK®/TAM Table 2. Igniter/Inducer ha reconnecting the S9200U1000 back. Gas valve failed to energize 17 Display/Diagnostics/EnviraLNK®/TAM pplicable 3+2 Bad Fuse Check: Wiring (limit, Ifrollout, pressure switch replace the control.a there is still no activity, 4 IGN-NEUTRAL Igniter Neutral Reversed line polarity 33 Display/Diagnostics/EnviraLNK®/TAM Electronics down 18 Display/Diagnostics/EnviraLNK®/TAM Single Blink Bus Activity Received Not Applicable (normal operation) Reversed line polarity 33LED isDisplay/Diagnostics/EnviraLNK®/TAM This active even if a conventional thermostat is controlling the appliance. shorted to chassis; EnviraCOM bus); gas valve Pin # Reference Lette Low voltage is detected on 24 Vac input 125 Display/Diagnostics/EnviraLNK®/TAM message acknowledgment could be shorted. Earth ground problem 88 Display/Diagnostics/EnviraLNK®/TAM Reversed line polarity 33 Display/Diagnostics/EnviraLNK®/TAM a Earth ground 88 Display/Diagnostics/EnviraLNK®/TAM This LED is active even if a conventional is controlling the appliance. (normal operation) 1 IND-HOT Turn off the power thermostat and replaceOff the fuse with aproblem A bad fuse has been detected (NOTE: This 92 Display/Diagnostics/EnviraLNK®/TAM No Bus ActivitySTATUSCheck/Repair: Disconnect the S9200U1000 CODES HISTORY fuse of theAsame type. 87 Display/Diagnostics/EnviraLNK®/TAM is stored in the Status Code History) A manual reset is required due to Rollout Earth ground problem 88 alarmDisplay/Diagnostics/EnviraLNK®/TAM external bus wiring, cycle power and manual reset is required due to Rollout 87 from the Display/Diagnostics/EnviraLNK®/TAM 2 IGN-HOT Cycle power to appliance and run heating Limit Automation and Control Solutions check the busstores activity. Ifthe thereten is activity, STATUS CODES HISTORY The S9200U1000 (10) most recent error codes. These Limit Automation and Control Solutions valve relay was sensed as closed 100 Display/Diagnostics/EnviraLNK®/TAM A manual reset is required due to Rollout 87 The gas Display/Diagnostics/EnviraLNK®/TAM sequence. repair bus wiring/devices before unning, inducer could be codes can beexternal recalled for viewing during troubleshooting and cleared if S9200U1000 UNIVERSAL HOT SURFACE IGNITION INTEGRATED FURNACE CONTROL 3 A manual reset is required dueand to gasControl valve 124 Display/Diagnostics/EnviraLNK®/TAM when it should be open Limit If this failure repeats, replace the control. Automation Solutions Honeywell International Inc. Honeywell Limited-Honeywell LimitéeIND-NEUTRAL A manual reset is required due to These gas valve necessary. 124 Display/Diagnostics/EnviraLNK®/TAM The S9200U1000 stores the ten (10) most recent error codes. reconnecting the S9200U1000 back. d,oneywell or inducer Limitée relay K4 may Honeywell International Inc. Honeywell Limited-Honeywell Limitée welded condition being detected more times welded condition being detected more timesif If there is still no activity, replace the control. codes recalled during troubleshooting and cleared 4 IGN-NEUTRAL e failed. Electronics down 18 Honeywell Display/Diagnostics/EnviraLNK®/TAM A manual reset is required due to gas valve 124 Display/Diagnostics/EnviraLNK®/TAM 1985 Douglas Drive North 35 Dynamic Drive 3+4 Gas valvecan errorbe - Miswire or for viewing Check/Repair: Gas valvethan wiring. than allowed maximum International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive allowed maximum e voltage; Pressure switch necessary. welded condition being detected more times welded (Control restarts if the Cycle power to appliance and run heating Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 isconnected or leaking; Reversed line polarity 33 Display/Diagnostics/EnviraLNK®/TAM a Drive Drive Flame 1985 currentDouglas caution level whileNorth running 4 35 DynamicDisplay/Diagnostics than allowed V 4Z9 Golden Valley, MN 55422 Toronto, Ontario M1V maximum 4Z9 error recovers and it has not sequence. This LED activelevel even if arunning conventional is controlling appliance. Recalling the Status Code the History ENVIRACOM COMMUNICATIONS Flame currentiscaution while 4thermostat Display/Diagnostics Table 12. Test Mode Parameters g blocked or obstructed. Flash been detected timesStatus yet) If this failure repeats, replace the control. RedfiveLED Code customer.honeywell.com Valley, MN 55422 Toronto, Ontario M1V 4Z9 EarthDisplay/Diagnostics ground problem 88 Golden Display/Diagnostics/EnviraLNK®/TAM customer.honeywell.com You may perform the following procedure multiple times to confirm that Flame current caution level while running 4 feature on a EnviraCOM™ communication is a standard the Code and Error Description Check / Repair ; inducer relay (K4) could Test Mode Parameter Modified Timing TEST87MODE 3+5 Control failed Self Check, internal Cycle power to appliance and run heating HISTORY STATUS CODES you have viewed all the currently stored error codes. TEST MODE customer.honeywell.com S9200U1000. EnviraCOM™ can be used to control system operation A manual reset is required due to Rollout Display/Diagnostics/EnviraLNK®/TAM welded. hardware (Control sequence.Check/Repair: If this failure repeats, replace the 4error, + 1 or failedHard Lockout - Rollout circuit restrictions; heatstores exchanger Limitadvanced by way of an EnviraCOM™ enabled thermostat and perform 5 seconds minal wiring (shorted); Automation and Control Solutions TEST MODE TheFlue S9200U1000 the ten (10) most recent error These The S9200U1000 isPre-Purge equipped with a Test Mode feature which allows restarts if theopen errororrecovers.) control. To recall the error code codes. history and display it via the red status LED, The S9200U1000 is equipped with a Test Mode feature which allows previously opened. restricted cts (closed when should diagnostics when connected to EnviraCOM™ enabled diagnostic tools This covers hardware errors like codes can be recalled for viewing during troubleshooting and cleared if perform the following: to test HSI andWarm-up verify several critical parameters. During Test A manual reset is required due toallows gas valve the control 124 Display/Diagnostics/EnviraLNK®/TAM 17 seconds Check burner. Check Rollout Switch including Honeywell International Inc. Honeywell Limited-Honeywell Limitée witch hoses have water the control to test and verify several critical parameters. During Test The S9200U1000 is equipped with a Test Mode feature which such as the web based EnviraLNK® remote diagnostics application, the flame sense circuit faults, pin necessary. welded condition being detected more times Mode, the S9200U1000 alters the selected Safety Timings as described switch cables. r obstruction. shorts, etc. OnWatch QuickLook™ 72 and theseveral W8735D Telephone Access Module Mode, the S9200U1000 alters the selected Safety Timings as described the control to test and verify critical parameters. During Test 1. Jumper the thermostat screw-terminal R/2 to 1985 Douglas 35 Dynamic Drive Ignition Activation 3 secondsDrive North than allowed maximum Reset rollout if necessary. in Table 14. (TAM). In addition to alarms, key information such as state and flame terminal D/1. nducer is running. Do not in operate Table until 14.repairs are made. Mode, the S9200U1000 alters the selected Safety Timings as described 3+6 Reversed Line Voltage Polarity or Check: Golden1Valley, Toronto, Ontario M1V 4Z9 Flame Recognition second MN 55422 Flame current caution level while running 4 Display/Diagnostics current can be sent over the EnviraCOM™ bus. See Table 13. icted venting; low input Cycle power to appliance and run heating • Within 0.5 seconds, the red status LED stops normal Poor Earth Ground (Control 1. Line voltage input wiring. Assure in Table 14. ® U.S. Registered Trademark ® U.S. Registered Trademark orizontal vent length. customer.honeywell.com operation and turns on solid to indicate that the jumper is restarts if the error recovers line voltage hot lead issequence. attached to Trial for Ignition 4 seconds © 2007 Honeywell International Inc. provides a quick overview for the This following service procedure If this failure © 2007 Honeywell International Inc. within 5 minutes after the fault L1. repeats, replace the control. Table 11. S920001000 EnviraCOM Alarms sensed. ® U.S. Registered Trademark TEST MODE 69-2087 IFC. J.Z. For 08-07 S9200U more information, refer to form 69-2075. 69-2087 69-2087 08-07 Heat Fan International ON Delay 15 seconds has cleared.) Ground wire from control to69-2087 appliance andwiring. 2. Keep the thermostat screw-terminal R/2 to D/1J.Z. jumpered. © 2007 Honeywell Inc. 4+2 Hard Lockout - Gas valve 2. welded Check/Repair: Gas valve appliance earth to ground. Alarm The S9200U1000 is equipped with a Test 69-2087 ModeHeat feature which allows cted airflow through heat • After a 5 second time-out, the red status LED turns off, 69-2087 J.Z. 08-07 relay detected for five times Cycle power appliance and run heating Fan OFF Delay 0 seconds 3. Voltage between line voltsequence. Neutral and WIRING HARNESSES ilters; slow circulator fan Comment 69-2087 7 recall is pending. 69-2087Alarm Description 8Number the control 69-2087 indicating that error code 00U1000 UNIVERSAL HOT SURFACE IGNITION INTEGRATED FURNACE CONTROL to test and verify several critical parameters. During Test9 69-2087 8 9 69-2087 appliance chassis. If over 10 volts, repair the peed. If this failure repeats, replace the control. Post-Purgeas described 5 seconds wiring or move the 7furnace to another circuit with Table 1. Main harness plug connector 12-pin alters the selected Safety Timings This device has no alarms 0 9 Mode, the NotS9200U1000 Applicable 69-2087 69-2087 8 69-2087 a good earth ground. (Class 2, Low Voltage). rictions. Increase airflow 3. Within 10 seconds of the red status LED turning off, remove the Cool Fan ON Delay 2 seconds in Table 14. a Flash Code Descriptions: Pressure switch failed to close in the ignition 1 Display/Diagnostics ease motor speed, open thermostat screw-terminal R/2 toENVIRACOM terminal Pin # Function Repair: Reverse line voltage inputs ifStatus line volt hot Recalling the Code History COMMUNICATIONS sequence Pulse: A 0.25 second flash followed by 3.75 seconds of off time. Cool Fan OFF Delay 0 seconds dd more returns). Table 12. Test Mode Parameters ® U.S. Registered Trademark ash D/1 jumper. Red LED Status Code - Heartbeat: Constant 0.5 second bright, lead is not attached the L1 input. 1 High Limit Out 0.5 second dimtocycles. © 2007 Honeywell International Inc. You may perform the following procedure multiple times to confirm • This activates thethat error code recall. EnviraCOM™ communication is a standard feature thein the ignition Pressure switch failedon to open 3 Display/Diagnostics de a and Error Description - During start-up Check / Repair Test Mode Parameter Modified Timing the STATUS LED blinks fast for approximately 2 seconds. If the 69-2087 J.Z. 08-07 you have viewed all the currently stored error codes. 2 Flame Sense - Flame Signal Input (90 Vac, current limited) Hard Lockout Codes sequence S9200U1000. EnviraCOM™ can be used to control system operation S9200U1000 fast (8 pulses/second), the control has failed and Gas + 1 valve leakage. Hard Lockout - Rollout circuit Check/Repair: Fluecontinues restrictions;blinking heat exchanger 3 24 Vac Hot IMPORTANT by way of an EnviraCOM™ enabled thermostat and opened perform advanced Pre-Purge 5 seconds To recall the error code history and display it via the red status LED, The pressure switch in run or trial 98 Display/Diagnostics must be replaced. open or previously opened. restricted If the R/2 to D/1 terminal jumper is not removed within theto EnviraCOM™ diagnostics when connected diagnostic 4 Not Used (TBD) 7 69-2087 8 for moreenabled 9 69-2087 than the allowable time tools theXfollowing: - Standard LED FaultRollout Pattern (Single X Flash):perform LED69-2087 flashes times at 2HZ, then off HSI Warm-up 17 seconds Check burner. Check Switch including 10 seconds, the history will be erased. such as the web based EnviraLNK® remote diagnostics application, the 5 Rollout Switch Out switch cables. for 3 seconds. Limit switch open Display/Diagnostics OnWatch QuickLook™ 72 and the W8735D Telephone Access Module 26 Jumper thermostat R/2 to Ignition Activation 3 seconds Reset - Advanced LEDrollout Faultif necessary. Pattern (X + Y Flash): LED1. flashes X timesthe at 2Hz, remains screw-terminal 6 24 Vac Common 4. Each saved error code blinks once on the red status LED, (TAM). In addition to alarms, key information such as state and flame terminal operate until flashes repairs are Flame detected out of sequence 34 Display/Diagnostics off Do for not one second, Y made. times at 2Hz, remains off for threeD/1. seconds, and Flame Recognition 1 second 7 High Limit In + Pressure Switch Out starting with the most recently stored error current cancode. be sent over the EnviraCOM™ bus. See Table 13. Cycle power to appliance and run heating • Within 0.5 seconds, the red status LED stops normal then repeats. sequence. Soft lockout due to flame current 5 Display/Diagnostics 8 Chassis Ground operation and turns on solid to indicate that the jumper is 6 69-2087 Trial for Ignition 4 seconds This following service procedure provides a quick overview for the NOTE: If there are no error codes to display, the red status LED immediately returns to norIf this failure repeats, replace the control. Table 11. S920001000 EnviraCOM Alarms Main Valve Common Table 10. E-Com Status Codessensed. S9200U IFC. For more information, refer9to form 69-2075. mal operation. Soft Lockout due to recycle; last recycle 85 Display/Diagnostics Heat Fan ON Delay 15 seconds 2. Keep the thermostat screw-terminal R/2 to D/1 jumpered. +2 Hard Lockout - Gas valve welded Check/Repair: Gas valve wiring. 10 Pressure Switch In Alarm was from pressure switch open • After a 5 second time-out,5.the After red status LEDcode turnsdisplays, off, Green LED Status relay detected for five times Cycle power to appliance and run heating last error the red status LED returns to norHeat Fan OFF Delay 0 seconds 11 Rollout Switch In WIRING HARNESSES Alarm Description Number Comment The maximum number of flame loss 22 Display/Diagnostics sequence. Code and indicating that error code recallmal is pending. operation. incidents has been exceeded 12 Main Valve If this failure repeats, replace the control. a Post-Purge 5 seconds Table 1. Main harness plug connector 12-pin This device has no alarms 0 Not Applicable Flash Code Check / Repair Description (Class 2, Low Voltage). Soft Lockout due to recycle; last recycle 86 Display/Diagnostics 3. Within 10 seconds of the red status LED turning off, remove the Cool Fan ON Delay 2 seconds sh Code Descriptions: Igniter/Inducer Harness Plug Connections Pressure switch failed to close in the ignition 1 Display/Diagnostics was from limit switch open Rapid Flashing Bus Activity - Message being Not Applicable (normalscrew-terminal operation) thermostat R/2 to terminal Pin # Function sequence e: A 0.25 second flash followed by 3.75 seconds of off time. Cool Fan OFF Delay 0 seconds transmitted D/1 jumper. Table 2. Igniter/Inducer harness plug Connector 4-Pin Gas valve failed to energize 17 Display/Diagnostics/EnviraLNK®/TAM 1 High Limit Out rtbeat: Constant 0.5 second bright, 0.5 second dim cycles. • This activates the error code recall. Pressure switch failed to open in the ignition 3 Display/Diagnostics Single Blink Bus Activity Received Not Applicable (normal operation) ng start-up the STATUS LED blinks fast for approximately 2 seconds. If the Pin # (90 Vac, current Reference Lettering Function 2 Flame Sense Flame Signal Input limited) Low voltage is detected on 24 Vac input 125 Display/Diagnostics/EnviraLNK®/TAM sequence message acknowledgment 200U1000 continues blinking fast (8 pulses/second), the control has failed and 3 24 Vac IMPORTANT 1 Hot IND-HOT Inducer 120 Vac A bad fuse has been detected (NOTE: This 92 Display/Diagnostics/EnviraLNK®/TAM The pressure switch opened in run or trial 98 Display/Diagnostics st be replaced. Off No Bus Activity Check/Repair: Disconnect the S9200U1000 If the R/2 to D/1 terminal jumper is not removed within the 4 Not Used (TBD) alarm is stored in the Status Code History) for more than the allowable time dard LED Fault Pattern (Single X Flash): LED flashes X times at 2HZ, then off from the external 10 bus wiring, cycle power and 2 IGN-HOT Igniter 120 Vac seconds, the history will be erased. 5 Rollout Switch Out check the bus activity. If there is activity, 3 seconds. The gas valve relay was sensed as closed 100 Display/Diagnostics/EnviraLNK®/TAM Limit switch open 26 Display/Diagnostics repair external bus wiring/devices before 3 IND-NEUTRAL Inducer Neutral anced LED Fault Pattern (X + Y Flash): LED flashes X times at 2Hz, remains 6 24 Vac Common when it should be open 4. Eachthesaved errorback. code blinks once on the red status LED, reconnecting S9200U1000 Flame detected out of sequence 34 Display/Diagnostics or one second, flashes Y times at 2Hz, remains off for three seconds, and 7 High Limit In + Pressure Switch Out IGN-NEUTRAL starting with thethe most recently stored error code. If there is still no activity, replace control. 4 Igniter Neutral Electronics down 18 Display/Diagnostics/EnviraLNK®/TAM n repeats. Soft lockout due to flame current 5 Display/Diagnostics 8 Chassis Ground NOTE: If there are no error codes to display, the red status LED immediately returns to norReversed line polarity 33 Display/Diagnostics/EnviraLNK®/TAM a This LED is active even if a conventional thermostat is controlling the appliance. 9 Main Valve Common Table 10. E-Com Status Codes mal operation. 85 Display/Diagnostics Soft Lockout due to recycle; last recycle 16_Troubleshooting_p295.indd 254-255 3/24/08 4:30:21 PM Earth ground problem 88 Display/Diagnostics/EnviraLNK®/TAM was from pressure switch open 10 Pressure Switch In
econds
4+1
Hard Lockout - Rollout circuit open or previously opened.
TECHNICIAN’S Q
16 technical information
S9200U1000 Universal Hot Surface Ignition Integrated Furnace Control
TECHNICIAN’S QUICK REFERENCE GUIDE
S9200U1000 Universal Hot Surface Ignition Integrated Furnace Control
TECHNICIAN’S QUICK REFERENCE GUIDE
254
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
255
Technical Information Carlin Ignitor Testing Procedure This test procedure consists of three tests. The first test should be the ignitor spark test. The second test is a secondary coil resistance test. The third test consists of an input current test. The following is a step by step procedure to perform these tests. It is important that all three of these tests be performed.
7.
SECTION
SECTION
16
16
resistance is more than 10%, the secondary coil may be failing. Replace the ignitor. If the difference between electrode-to-ground is within 10%, proceed with the input current test.
41000 Ignitor Spark Test
Figure 1
1. Turn off the power to the burner/appliance. 2. Release the ignitor hold down screws or clips. 3. Swing the ignitor plate fully open. 4. Use an ohmmeter to check the resistance from electrode to ground for each of the electrodes. (see figures 2 & 3) 5. The secondary coils are good if the difference between the two readings is less than 10%. 6. If the difference in the electrode-to-ground
256 16_Troubleshooting_p295.indd 256-257
F.W. Webb Company
Figure 3
41000 Input Current Test
1. Turn off the power to the burner/appliance. 2. Disconnect the ignitor wires in the burner junction box. 3. Release the ignitor hold down screws or clips. 4. Swing the ignitor plate fully open. 5. Bend the copper ignitor clips or springs until the clip ends are 1/2” apart. 6. Set a multimeter to read AC milliamps. 7. Using a test power cord with a switch, wire the ignitor blue lead to one of the multimeter leads. Wire the other lead of the mutimeter to the hot side of the test cord. Wire the white ignitor wire to the neutral side of the test cord. 8. Insure the multimeter is set for AC milliamps and turn on the test power cord switch to power the ignitor. If there is no spark, replace the ignitor. 9. Monitor the input current with the multimeter set on AC milliamps for 5 minutes. 10. If at any time the reading drops below 300 milliamps AC, the ignitor should be replaced. 11. Turn off the power to the ignitor. 12. Remove the power test cord. 13. Re-adjust ignitor clip spacing (1 inch 1/8 inch). 14. Wire the ignitor in its original condition (per burner wiring diagram). 15. Replace all components to normal condition.
Figure 4
www.fwwebb.com
Fuel Valves No. 1 fuel oil - 135,000 BTU per gallon No. 2 fuel oil = 140,000 BTU per gallon No. 4 fuel oil = 155,000 BTU per gallon No. 5 fuel oil = 150,000 BTU per gallon No. 6 fuel oil = 153,000 BTU per gallon Natural gas = 1,000 BTU per cubic foot Natural gas = 100,000 BTU per Therm Manufactured gas = 550 BTU per cubic foot Propane = 2,250 BTU per cubic foot Propane = 92,000 BTU per gallon Electricity = 3,415 BTU per kWh Anthracite coal = 13,700 BTU per pound Bituminous coal = 12,500 BTU per pound Wood = 14,000,000 BTU per mixed cord Fahrenheit to Celsius = (°F – 32°) / 1.8 Celsius to Fahrenheit = C° X 1.8 + 32°
EDR for Hot water Radiators Average Water Output in BTUH Temp °F per sq. ft. EDR 150 110 155 120 160 130 165 140 170 150 175 160 180 170 185 180 190 190 195 200 200 210 205 220 210 230 215 240* 220 250 (also for 1 psi steam) The F.W. Webb Heating Catalog
Maximum copper tubing flow rates and BTUH loads (at 20**T) 1/2” = 1 – _ GPM = 15,000 BTUH 3/4” = 4 GPM = 40,000 BTUH
16
1” = 8 GPM = 80,000 BTUH 11/4_” = 14 GPM = 140,000 BTUH 11/2_” = 22 GPM = 220,000 BTUH 2” = 45 GPM = 450,000 BTUH
Pump Head Rule of Thumb Measure longest run in feet. Allow 6 feet of pump head per 100 feet (this incudes an allowance for the fittings and the boiler).
technical tips
41000 Secondary Coil Resistance Test
Figure 2
EDR to Pounds of Condensate per hour (Divide EDR by 4) EDR to GPM (Multiply EDR by 0.005) EDR to BTUH at 1 psig steam pressure (Multiply EDR by 240) EDR to Boiler Horsepower (Divide EDR by 140) EDR to grate Area in Square Feet (Divide EDR by 140) BTUH to EDR (Divide BTUH by 240) BTUH to Boiler Horsepower (Divide BTUH by 33,475) PSIG to Feet of Water (Multiply PSIG by 2.31) Boiler Horsepower to Pounds of Condensate per hour (Multiply BHP by 34.5) Boiler steaming rate (regardless of type or manufacturer) = 1/2 GPM per 1,000 sq. ft. EDR
technical information
1. Turn off the power to the burner/appliance. 2. Disconnect the ignitor wires in the burner junction box. 3. Release the ignitor hold down screws or clips. 4. Swing the ignitor plate fully open. 5. Bend the copper ignitor clips until the clip ends are from 5/8” to 3/4” apart. (see figure 1) 6. Connect a test power cord with a switch to the ignitor leads in the burner junction box. 7. Turn on the test power cord switch to power the ignitor. 8. Check for spark across the ignitor clip ends. 9. If spark occurs, proceed the secondary coil test below. 10. If spark does not jump the gap, or if the spark jumps intermittently, ignitor is defective and should be replaced. 11. Turn off power to the ignitor.
Helpful Tips
Data courtesy of Heatinghelp.com
F.W. Webb Company
257 3/24/08 4:30:24 PM
SECTION
16
16
To increase the concentration of the solution in the system, determine the percent of glycol in solution and apply the following equations: Qa = Vs (Pd - Pt) (100 - Pt) Qa = Quantity, in gallons, to be added Vs = System volume Pd = Percent of solution desired Pt = Percent of solution by test (initial percent) Drain the determined number of gallons from the system and refill with glycol concentrate.
3/4”
1” 11/4” 11/2” 2” 21/2”
0.016 0.027 0.044 0.077 0.105 0.173 0.248
2
3
4
5
6
7
8
9
10 10
TOTAL HEAD (ft)
30 25
9 009
8 7
20 0014
6 5
15
6 10
3 2
5 0 003 0 5
COPPER TUBE - NOM.
0.015 0.025 0.044 0.68 0.095 0.160 N/A
0013 0010
006 008 005 007 0011 10
15
20
25
30
0012
35
40
1
45
TOTAL FLOW (gpm)
Three Speed Circulator Performance Field – 60Hz 0.0
0.5
1.0
1.5
2.0
16 technical information
1/2”
FLOW M3/H
35
Qa = 120 (50 - 30) (100 - 30) Qa - 34.3 gallons required STEEL PIPE - IPS
00 Circ 1
Example: System volume = Vs = 120 gallons Initial percent of solution from test = Pt = 30% (+4ºF freezing point) Percent of solution desired = Pd = 50% (-34ºF freezing point)
PIPE SIZE
Technical Information
TOTAL HEAD (m)
Adding Antifreeze
SECTION
FLOW M3/H 2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
24
3-Speed Circulators
20
6.5 6.0 5.5
00R
16
H High – Speed 3
5.0
M Medium – Speed 2
4.5
L Low – Speed 1
4.0
14
12 3.5 10 3.0 8
2.5
6
TOTAL HEAD (m)
TOTAL HEAD (ft)
18
technical tips
7.0 22
2.0
0010
1.5
4
1.0
2
0.5 0
0.0 0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29 30
TOTAL FLOW (gpm)
258 16_Troubleshooting_p295.indd 258-259
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
259 3/24/08 4:30:25 PM
Technical Information
SECTION
SECTION
16
16
Technical Information Wiring Diagrams
110-120
for SWG Power Venter or DI Draft Inducer CK-61 or 63 for an Oil Fired Boiler, Furnace or Water Heater
3
FLOW (M /H) 2
4
6
8
10
12
14
25
(with standard primary control) 7 6 5
15 4 10
3
TOTAL HEAD (m)
TOTAL HEAD (ft)
20
16
2
technical information
5 1
0
10
20
30
40
50
60
70
FLOW IN GALLONS PER MINUTE
CK-63 for an Oil Fired System with Honeywell (R8184P, R7184P), Carlin 60200-02, or Equivalent Primary Control
Table 1-N
Quick Pipe Sizing Table Recommended Flow Rates in GPM For All Piping Except Branch Connections on Taco Venturi Sytems Nominal pipe or tubing Size In.
Minimum GPM
Velocity ft/sec.
MAXIMUM GPM
VELOCITY ft./sec.
Minimum GPM
Velocity ft/sec.
MAXIMUM GPM
VELOCITY ft./sec.
1/2”
—
—
1.8
1.9
—
—
1.5
2.1
3/4”
1.8
1.1
4.0
2.4
1.5
1.0
3.5
2.3
1”
4.0
1.5
7.2
2.7
3.5
1.4
7.5
3.0
11/4”
7.2
1.6
16.0
3.5
7.0
1.9
13.0
3.5
11/2”
14.0
2.2
23.0
3.7
12.0
2.1
20.0
3.6
steel pipe
copper tubing
23.0
2.3
45.0
4.6
20.0
2.1
40.0
4.1
40.0
2.7
70.0
4.7
40.0
2.7
75.0
5.1
3”
70.0
3.0
120.0
5.2
65.0
3.0
110.0
5.2
31/2”
100.0
3.2
170.0
5.4
90.0
3.1
150.0
5.2
4”
140.0
3.5
230.0
5.8
130.0
3.5
210.0
5.6
5”
230.0
3.7
400.0
6.4
—
—
—
—
6”
350.0
3.8
610.0
6.6
—
—
—
—
8”
600.0
3.8
1200.0
7.6
—
—
—
—
10”
1000.0
4.1
1800.0
7.4
—
—
—
—
12”
1500.0
4.3
2800.0
8.1
—
—
—
—
260 16_Troubleshooting_p295.indd 260-261
F.W. Webb Company
www.fwwebb.com
technical tips
2” 21/2”
The F.W. Webb Heating Catalog
F.W. Webb Company
261 3/24/08 4:30:26 PM
Technical Information
SECTION
SECTION
16
16
Wiring Diagrams
Technical Information Wiring Diagrams
for SWG Power Venter or DI Draft Inducer CK-60 or 61 for an Oil Fired Warm Air Furnace with Electronic Primary Control
for CAS Units CAS-3 Chimney Vent, Single Oil Fired System with Standard Primary Control
16
(operates the venter motor and burner simultaneously)
CAS-3 Power Vent, Single Oil Fired System with Standard Primary Control
technical information
CK-63 for an Oil Fired System with Primary Control
technical tips
262 16_Troubleshooting_p295.indd 262-263
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
263 3/24/08 4:30:27 PM
Technical Information
SECTION
SECTION
16
16
Sizing Expansion Tanks
HT and SXHT Hydronic Heating Expansion Tanks
Wiring Diagrams
Quick Sizing Chart
for CAS Units CAS-4 Power Vent, Single 24 Volt Gas Appliance
boiler output net btuh (1,000’s)
CAS-4 Chimney Vent, Single 24 Volt Gas Appliance
baseboard copper
cast iron
unit heaters connectors
cast iron radiators
20 HT15 HT15 HT15 HT15 30 HT15 HT15 HT15 HT15 40 HT15 HT30 HT30 HT30 50 HT15 HT30 HT30 HT30 60 HT30 HT60 HT30 HT60 70 HT30 HT60 HT30 HT60 80 HT30 HT60 HT30 HT60 90 HT30 HT60 HT30 HT60 100 HT30 HT60 HT30 HT60 125 HT30 HT90 HT60 HT60 150 HT30 HT90 HT60 HT90 175 HT60 HT90 HT60 HT90 200 HT60 HT90 HT60 HT90 250 SXHT30 SXHT30 SXHT30 SXHT40 300 SXHT30 SXHT30 SXHT40 SXHT40 SXHT30 SXHT40 SXHT60 350 SXHT30 SXHT40 SXHT60 SXHT90 400 SXHT30 SXHT40 SXHT60 SXHT90 500 SXHT40 SXHT60 SXHT90 SXHT90 600 SXHT40 SXHT60 SXHT90 SXHT90 700 SXHT60 SXHT90 SXHT110 SXHT110 800 SXHT60 SXHT90 SXHT110 SXHT110 900 SXHT60 SXHT90 SXHT110 SXHT110 1000 SXHT90 SXHT90 SXHT110 SXHT160 1200 SXHT90 1400 SXHT110 SXHT110 SXHT160 SXHT160 1500 SXHT110 SXHT110 SXHT160 (2) SXHT110
16 technical information
Radiation
264 16_Troubleshooting_p295.indd 264-265
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
technical tips
These recommendations are based on average closed systems Fill pressure 12 PSI, relief pressure 30 PSI, system temperature 200°F
F.W. Webb Company
265 3/24/08 4:30:27 PM
Sizing the Boiler to the Radiation
SECTION
SECTION
16
16
Tubular Radiation Rating - Square Feet per Section Height
3 tube
4 tube
5 tube
6 tube
7 tube
14”
2.67
17”
3.25
20”
1.75
2.25
2.67
3.00
3.67
23”
2.00
2.50
3.00
3.50
26”
2.33
2.75
3.50
4.00
4.75
32”
3.00
3.50
4.33
5.00
5.50
38”
3.50
4.25
5.00
6.00
6.75
Column Radiation Rating - Square Feet per Section 3 tube
4 tube
5 tube
6 tube
7 tube
duct height inches
air volume CFM
4”
50
6X4
6”
8”
10”
12”
equivalent air volume round duct ” cfm 5
50
75
6X4
6
75
100
8X4
6X6
6
100
125
10 X 4
6X6
7
125
150
10 X 4
8X6
7
150
175
12 X 4
8X6
8
175
200
14 X 4
8X6
8
200
225
16 X 4
10 X 6
8
225
250
16 X 4
10 X 16
9
250
9
275
275
12 X 6
300
12 X 6
8X8
9
300
400
14 X 6
10 X 8
10
400
500
18 X 6
12 X 8
10 X 10
11
500
600
20 X 6
14 X 8
12 X 10
12
600
8X8
14”
4.00
700
24 X 6
16 X 8
12 X 10
121
700
17”
4.00
800
26 X 6
18 X 8
14 X 10
12 X 12
13
800
5.00
900
30 X 6
20 X 8
16 X 10
12 X 12
14
900
5.00
1000
22 X 8
16 X 10
14 X 12
14
1000
6.00
1100
24 X 8
18 X 10
16 X 12
15
1100
18”
2.25
20”
1.50
2.00
23”
1.67
2.33
26”
2.00
32” 38”
22”
3.00 4.00
1200
26 X 8
20 X 10
16 X 12
15
1200
2.67
3.75
5.00
1300
28 X 8
20 X 10
18 X 12
16
1300
2.50
3.33
4.50
6.50
1400
30 X 8
22 X 10
18 X 12
16
1400
3.00
4.00
5.00
8.00
1500
24 X 10
20 X 12
16
1500
10.00
1600
24 X 10
20 X 12
17
1600
1700
26 X 10
22 X 12
17
1700
1800
28 X 10
22 X 12
18
1800
1900
30 X 10
22 X 12
18
1900
24 X 12
18
2000
44” 45”
5.00
6.00
radiant convector
2000
width
height
sq. ft. per section
5”
20”
2.25
71/2”
20”
3.40
technical tips
3.00
16 technical information
Height
Duct Sizing
cast iron baseboard
266 16_Troubleshooting_p295.indd 266-267
width
height
sq. ft. per linear Foot
21/2”
10”
3.40
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
267 3/24/08 4:30:28 PM
Oil Tank Chart
SECTION
SECTION
16
16
Balancing One-Pipe Steam Systems
BALANCING ONE-PlPE-STEAM SYSTEMS
16_Troubleshooting_p295.indd 268-269
275
550
1000
1080
26”
42”
48”
48”
48”
1”
6 gal.
2
3
5
8
2
14
5
8
14
19
3
23
9
14
26
32
4
33
14
22
40
47
5
43
20
30
55
64
6
54
26
40
72
83
7
65
32
50
90
103
8
77
39
61
110
124
9
89
46
72
130
145
10
100
53
84
151
169
11
113
60
96
173
193
12
125
67
109
196
219
13
137
75
122
220
244
14
149
82
136
244
271
15
161
90
149
269
298
16
174
97
163
294
327
17
185
105
177
319
357
18
197
112
192
345
386
19
209
120
206
371
415
20
221
127
221
397
444
21
231
135
236
424
473
22
241
142
250
451
502
23
251
150
265
477
534
24
260
157
280
504
561
25
268
165
295
531
591
26
275
172
310
558
620
27
–
180
325
584
649
28
–
187
339
611
678
29
–
195
354
637
707
30
–
203
369
663
736
31
–
210
383
689
764
32
–
217
397
715
793
33
–
224
411
740
820
34
–
231
424
764
848
35
–
238
438
789
875
36
–
244
451
812
901
37
–
250
464
835
926
38
–
256
476
857
951
39
–
261
488
879
973
40
–
265
500
899
994
41
–
268
510
918
1014
42
–
271
519
935
1033
43
–
–
530
954
1050
44
–
–
538
969
1065
45
–
–
546
983
1078
46
–
–
552
994
1089
47
–
–
558
1004
1095
48
–
–
560
1007
–
F.W. Webb Company
Vent the mains quickly. This will help the steam get to all the radiators at about the same time. Steam is a gas and it will always look for a way out of the system. When it leaves the boiler, it heads toward the air vents. The bigger the air vent, the more inclined steam will be to head that way. If your system heats unevenly, install a main vent near the end of the each main and watch the difference it makes. Pipe the vent about a foot inches back from the end of the main, and six-to-ten inches up on a nipple to keep it away from any end-of-main water hammer. If you can’t get these exact dimensions, do the best you can. And remember, the bigger the hole, the faster the venting, so it pays to install a tee with a three-quarter-inch tapping for the vent near the end of the main. Don’t try to get by with a tiny hole drilled into the main. Tiny holes don’t vent quickly. Install a “Y’ strainer before the main vent. An old steam system can be plenty dirty! And since steam is moving at high velocity (typically, about 25 mph in a one-pipe system), it picks up particles of rust and sediment. Eventually, this stuff winds up inside the main vent. Before long, your main vents dog and can’t shut. They spit water and lets steam pass to the atmosphere. This creates water-Ievel problems at the boiler. A “Y” strainer, installed vertically before the main vent can protect the vent from system debris and increase its life. Use the strainer as part of your six-to-ten-inch elevation for the main vent and you’ll improve the system’s performance drastically. Then make sure you clean the strainer from time to time!
Vent the radiators based on their size
If your goal is to get all the radiators hot at about the same time on the coIdest day of the year, you’ll have to handle the air in a special way. First, as I said before, vent the mains quickly. That’s important. Then vent the radiators in relation to their size, not necessarily their location throughout the building. The main vents will help get the steam to each radiator at about the same time. Since big radiators contain more air than small radiators, big radiators should have larger air vents than small radiators. That makes sense, doesn’t it? Nevertheless, it’s a fine point in one-pipe steam that’s often misunderstood. Use two vents on oversized radiators. Oversized radiators are always a challenge. No matter what size vent you use, that vent will close once the steam reaches it – even If much of the air remains in that huge radiator. The Dead Men often faced this challenge by drilling and tapping those oversized radiators for a second air vent. They positioned the second vent a few inches lower than the first. The two vents then worked together to let the air out. When steam reached the first vent (the higher of the two), the vent closed. But the second vent (at the lower level) continued to vent air from the radiator. As a result, the radiator heated more completely, and took the Dead Men a step closer to system balance. This trick can work just as well for you!
www.fwwebb.com
The F.W. Webb Heating Catalog
Clean the system. If the boiler water is dirty, the steam will carry water with it when it heads off into the piping. This leads to water level problems at the boiler, of course, but it also creates balancing problems throughout the system. The steam gives up its latent-heat energy to the mist of water that’s traveling with it. That stops the steam dead in its tracks. The radiators furthest from the boiler remain cold while the radiators near the boiler room get warm. The burner often short-cycles when the steam quality is poor. This, too, leads to balancing problems. Check the boiler manufacturer’s cleaning instructions. It can take a day or two to get a boiler’s water back in “clean-steam” shape, but this is often the only solution to those balancing problems. Lower the steam pressure. Steam heating systems ride a wave of pressure from the “cut-in” to the “cut-out” setting of the pressuretrol or the vaporstat. The system must cycle up and down on that wave because that’s how the air vents work. Steam pushes the air from the vents; the vents then shuts on temperature. When the steam condenses, the vents are supposed to open to allow venting to continue. But if the system pressure is too high, the air vents might stay closed. Since air can’t escape from a closed air vent the radiators stay cool and the system goes out of balance. The air vents and the pressuretrol or vaporstat work together to move the air from the system. If you set the “cut-in” setting at one-half psi on a pressuretrol, or at about four ounces on a vaporstat, you’ll never lock the air vents closed. The “cutout” pressure should be as low as possible. There is no reason to raise the steam pressure any higher than it has to be. Highpressure steam actually moves more slowly than low-pressure steam. So when you’re trying to balance that one-pipe system, lower the pressure. Check the near-boiler piping against the boiler manufacturer’s specs. If you want a modern steam boiler to produce good quality, dry steam, you have to pipe it the way the boiler manufacturer recommends. Replacement boilers are much smaller than the boiler of the steam era. They use their near-boiler piping to separate the water from the steam. If you want the steam to reach those faraway radiators, it has to be dry. Proper near-boiler piping plays a huge role in the one-pipe-steam balancing act.
F.W. Webb Company
16
technical tips
268
275
technical information
inches of oil in the tank
tank Cap. gal.
Insulate the steam lines. When steam condenses and turns into water it stops moving. That’s why the Dead Men spent so much time insulating their steam mains. They wanted the steam to condense in the radiators, not in the basement piping. If the asbestos is gone, replace it with a more suitable material and that will help you balance the system because the steam won’t condense as quickly in the basement pipes. Uninsulated steam pipes have about five times the heat loss of insulated steam pipes so wrap them well and give the steam a chance to get where you want it to go.
269 3/24/08 4:30:28 PM
Insulating Steam Pipes WHY YOU SHOULD INSULATE STEAM PIPES When you take an old house under your wing you sometimes also get to take possession of an old steam heating system and an awful lot of asbestos insulation that goes along with it. There was a day when asbestos was touted as a miracle product. Nowadays, we know better, Some homeowners choose to contain the asbestos by carefully wrapping it in plastic while others decide to get rid of it once and for all. If you’re getting rid of asbestos there are a few things I want you to know.
16
16
Now, lake the insulation off that pipe and watch what happens. The heat loss of the pipe jumps to an incredible 13,250 BTUs per hour! That’s more than five times the heat loss that the insulated main suffered. And if your basement is colder (or if that runs through a cold crawl space), the heat loss will be even more extreme. And that’s why your basement is 90-degree cozy — even though you’re freezing in your bedroom. As I said, the load that the uninsulated pipes adds to the system can effectively undersize your boiler. When we size replacement steam boilers, we have to make sure the boiler’s ability to produce steam matches the system’s ability to condense steam. It’s like having an evaporator and a condenser in an air conditioning system. In this case, the boiler becomes the evaporator, and the system becomes the condenser. If the “condenser” (the system) is bigger than the “evaporator” (the boiler) the boiler can run for a long, long time before it shuts off because it wiIl never develop any pressure. This will be most apparent during the spring and the fall because the boiler has to overcome the heat loss of the bare pipe every time it starts. During the winter months, when the boiler runs for a longer time, the pipes won’t have as much of an opportunity to cool off, so the problem won’t be as noticeable. Spring and fall will drive you nuts, though. The heat loss of the piping is what steam boiler manufacturers call the “piping and pick-up” factor. When they rate their steam boilers they allow for a piping “pick-up” load that’s equal to one-third of the system’s total radiation load. In other words, they measure how much radiation there is, and then they add a third more boiler capacity to that to allow for the heat loss of the pipes that connect your boiler to your radiators. And they base this one-third “pick-up” factor on insulated mains because steam mains are supposed to be insulated. When the insulation’s gone, the “piping and pick-up” factor the boiler manufacturer built into the sizing chart will suddenly be too small. You can wind up with an effectively undersized boiler and cold rooms. So insulate all the steam pipes you can see. Tuck ‘em in and keep ‘em warm, And remember that the insulation doesn’t have to be fancy to work. You can use something as simple as batt insulation and duct tape n the aesthetics aren’t important to you (who cares what it looks like in that crawl space?). Your goal should be to give steam the best possible chance to get to where you are.
Insulation makes a huge difference when it comes to steam mains. Here’s an example. Suppose you have a 2-1/2” steel main that runs around your basement. Let’s say it’s 50 feet long. Okay, the original installer covered that main with a one-inchthick layer of asbestos insulation years before you were born, That was pretty standard practice. When the air in your basement is 70 degrees, the heat loss of that insulated main is going to be about 2,450 BTUs per hour. Naturally, if the air in your basement is colder than that, the heat loss from the main will be greater, but let’s figure that the air is 70 degrees, just for the sake of comparison.
270 16_Troubleshooting_p295.indd 270-271
F.W. Webb Company
WHAT YOU SHOULD KNOW ABOUT HARTFORD LOOPS
hThe piping arrangement wasn’t fail-safe, but it was a vast improvement over the old way of returning condensate directly into the bottom of the boiler.
A Hartford Loop is an arrangement of piping between a steam boiler’s header and its gravity-return piping. The end of the header drops vertically below the boiler’s waterline and connects into the bottom of the boiler. We call this pipe the “equalizer” because it balances the pressure between the boiler’s steam outlet and condensate-return inlet. The “wet” gravity return line, which returns the condensate from the system, rises up from the floor to join with the equalizer at a point about two inches below the boiler’s lowest operating water line.
Should you use a Hartford Loop nowadays? I sure think so! Your low-water cutoff should protect the boiler against a sudden loss of water, but if you have a gravity-return system, a Hartford Loop is the cheapest insurance you can buy to back up that low-water cutoff should a return rupture and water suddenly leave the boiler. Low-water cutoffs are great, but believe it or not, there are a few out there that don’t get blown-down once a week. Really!
The Dead Men didn’t always use this piping arrangement. They used to bring the return directly back into the bottom of the boiler without benefit of either a Hartford loop or an equalizer. When they piped a boiler this way, however, the slightest steam pressure would push water out of the boiler and into the return. They solved this problem by using a check valve in the wet return (that’s the pipe below the boiler water line). Before long, though, they found the check valve would fill with sediment and get stuck open. That caused the water to back out of the boiler again, so they developed the equalizer pipe to replace the check valve. Whatever pressure appears inside the boiler will also appeared inside the equalizer pipe if you size that pipe properly. The two forces balance each other, and the water stays in the boiler. Now, you may wonder what happens if a return line breaks. Well, water will flow from the boiler, and the boiler will either crack (dry-fire) or explode (if someone adds water while it’s dry-firing). That’s a sobering thought, isn’t it? Keep in mind there were no low-water cutoffs during the days of coal- and wood-fired boilers. E. N. McDonnell of McDonnell & Miller fame invented the first low-water cutoff in 1923. He had to wait for the invention of the oil burner before his product made any sense. Around 1919, the Hartford Steam Boiler Insurance and Inspection Company got tired of paying the claims on all those broken boilers, so they came up with the idea of this special piping configuration and mandated it for anyone who wanted insurance on their steam boiler. Before long, everyone was calling it the Hartford (or Underwriters) Loop. If you look at the records of boiler failures before and after 1919, you can see that the loop had a very positive impact on our industry. Here’s how the Hartford Loop works. If a return line breaks, water can only back out of the boiler to the point where the wet return line connects into the equalizer. The Loop works like a siphon that runs out of water. The point where the Loop connects to the equalizer is higher than the boiler’s crown sheet, and that’s what provides the safety. Since the water couldn’t instantly vanish from the boiler, it bought the Dead Men some time to notice the problem and save that wood- or coal-fired boiler.
www.fwwebb.com
Hartford Loops
The F.W. Webb Heating Catalog
The Loop connects into the equalizer through a close nipple and here’s why. Steam rises up through the equalizer, just as it does through the boiler sections. When the relatively cool return water meets that steam at the close nipple, the rising steam bubbles quickly condense. Naturally, the return water rushes in to fill the void left by the collapsing bubbles, and this creates a slight water hammer inside the tee connecting the return to the equalizer. If you use a long nippIe instead of a close nipple, the returning water will have more room to move, so it creates more water hammer through its inertia. Long nipples acts like gun barrels in this case, and you should always avoid them. Stick with a close nipple, or use a “Y” fitting. Generally, you should connect the close nipple about two inches below the bottom of the gauge glass, but check the boiler manufacturer’s specs on this. The centerline of the close nipple has to be below the water line, but above the boiIer’s crown sheet. And don’t install the close nipple two inches below the center of the gauge glass because that’s probably too high. You see, when the water leaves the boiler as steam, the level in both the boiler and the equalizer will drop. If it drops below the close nipple, steam will push down through the equalizer, enter the wet return and create water hammer. This usually happens near the end of the firing cycle, and it causes a very noticeable racket. If the system has a dry return (as most one-pipe steam system do) you still need a Hartford Loop. Consider a one-pipe steam system for a moment. The main works its way from the boiler header, around the basement, and then drops for the first time when it returns to the boiler. There are no return pipes below the boiler water line, so there’s no danger of losing the boiler water should an above-the-waterline return pipe break. But keep in mind that the near-boiler piping has an equalizer that keeps the water from backing out of the boiler when steam pressure builds. If you drop directly from the end of your steam main (the return) into the middle of your equalizer, you’ll set up a condition where steam might have access to the return line through the equalizer as the water line in the boiler steams down. By bringing your return line down to the floor, and then rising up into your equalizer (in other words, by building a Hartford Loop), you ensure that steam in the equalizer can never enter the return line and cause water hammer.
F.W. Webb Company
16
technical tips
But let’s say you decide to have that asbestos removed from your steam pipes. Are you going to replace it with a more suitable type of insulation? You should because if you don’t, you’re going to wind up with an undersized boiler. And with an undersized boiler, the rooms in your home will heat unevenly. Some will never get warm enough. Others will be too hot. If your thermostat is in a room that has a cold radiator, you fuel bills will probably also increase because your burner will run longer than it should. You’re also liable to get water hammer noise, especially if the asbestos abatement folks didn’t do a good job of reattaching your pipe hangers. Sags in the pipes cause water to form puddles, and puddles cause problems in steam heating systems.
SECTION
technical information
First, steam is a hot gas that desperately wants to give up its latent heat energy (an amazing 970 BTUs per pound!) and turn back into water. The steam will give up that tremendous amount of energy to anything that’s colder than it is. In most homes, the steam that leaves the boiler is about 215 degrees F. That’s hotter than just about everything else in the house, right? So when the steam hits a cold pipe, it will quickly make that pipe hot by condensing on it and releasing its latent heat energy. And as soon as the steam condenses, it stops moving because, at that point, it’s no longer steam. The colder the pipes are, the faster the steam will condense on them, and that’s why the builders of old houses covered the steam pipes with an asbestos “blanket.” Asbestos insulation keeps the steam hot. It prevents it from condensing too soon. It’s like a thermos bottle. The Dead Men wanted that steam to stay hot so that it would travel further – like to the upstairs bedrooms. You don’t need the basement to be 90 degrees, do you?
SECTION
271 3/24/08 4:30:28 PM
Hartford Loops
SECTION
SECTION
16
16
You base the size of the equalizer on the size of the boiler. Boilers up to 900 square feet EDR (D.O.E. Heating Capacity) should have an equalizer no smaller than 1-1/2”. If the boiler is rated between 900 and 6,400 square feet EDR, use a 2-1/2” equalizer. Boilers sized over 6,400 EDR should have an equalizer that’s four-inch in size. If your equalizer is too small it won’t balance the pressure on the return, and your boiler water line will be very unsteady.
UNDERSTANDING PRIMARY-SECONDARY PUMPING Primary-secondary pumping has become pretty popular nowadays, especially with boiler manufacturers. They love it because it offers a simple way to protect their boilers against low-temperature return water and the resulting flue-gas condensation that low-temperature water causes. This is a legitimate concern because more and more of us are involved with radiant heating where the water returning from the system can be as low as 90 degrees. It’s also a concern when you add a modern boiler to an old gravity hot water system. There’s nothing worse than hitting a hot boiler with cold return water.
If you’re using a condensate return pump, you really don’t need the Hartford Loop. As soon as you add that condensateor boiler-feed pump to a steam system, you open the returns to atmosphere. At that point, the equalizer stops being an equalizer, and becomes just a drip line for the header. All the return water must flow into the pump’s receiver, and from there, into the boiler. The pump has a check valve at its discharge to keep the boiler water in the boiler. Should the check valve fail, the water from the boiler will simply flow into the pump’s receiver, and start the pump. The pump will move the water back in the boiler and then shut off. Then it will do it again – over and over.
There’s nothing complicated about primary-secondary pumping. It all comes down to what happens when water flows through a tee. If water goes in, it has to come out. That’s common sense. But how it comes out makes all the difference in the world. With primary-secondary, you have to set the tees that lead to the secondary circuit no more than 12 inches apart. As the primary flow enters the first of the two tees, it “looks” ahead, and then makes a choice. It can either go straight for 12 inches and be past these two tees leading to the branch circuit, or it can divert through the first tee’s branch and flow through the entire secondary circuit. It becomes a question of which is the easier way.
Should the receiver spring a leak and the check valve fail at the same time, it’s possible for the boiler to lose its water, so you can use a Hartford Loop if the spirit moves you, but there is one large drawback. Every time the pump starts, it will shoot water under pressure through the close nipple and into that bullheaded tee in the header drip. Some of that water will probably fly up into the boiler header where it will create some bodacious water hammer. That’s why I think you’re better off piping your pump discharge into the bottom of the header drip, well below the boiler’s water line.
It’s pretty simple when you get right down to it. When the secondary circulator is off, no water will flow through the secondary circuit because the 12-inch “gap” between the tees in the primary main is the part of least resistance. And it doesn’t matter how large or small the primary and secondary circulators are either. They operate independently because they’re hydraulically disconnected. You size each circulator for the flow rate and pressure drop needs of only the circuit it serves, That’s why you usually wind up with lots of small inline circulators instead of one or two large, base-mounted pumps. The compression tank belongs in the primary main, as does the air separator and the fill valve. Make sure you install your primary circulator so that it pumps away from the compression
272 16_Troubleshooting_p295.indd 272-273
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
The secondary circulators use the common piping between the primary and secondary circuits as their “compression tank.” Always pipe your secondary circulators so they pump away from the primary loop and toward the radiation. On most jobs, you’ll connect your secondary circuits in a manifold off the two primary-to-secondary tees. Pipe the manifold the same way you would if you were connecting it to a boiler. If one or more of your secondary zones are going to serve a radiant heat zone, use a two-, three-, or four-way valve to mix the water returning from your zone into the hot supply water from the primary circuit. Pipe your secondary circulator on the radiation side of the two-, three-, or four-way valve. Use fIow-control valves to stop gravity circulation from the primary to the secondary circuits. I didn’t always preach this but I’ve learned from experience that it pays to have those flow-control valves in place. And depending on the piping configuration, you might need them on both the supply and return sides of the secondary circuits to stop gravity circulation. We call the system I’ve been describing “one-pipe, primarysecondary pumping.” The primary circulator moves the boiler water through the primary circuit. When the flow of cooler water returns from the secondary circuit, the hot primary water, which jumped the “gap” between the two tees mixes with the return water. The hotter water instantly raises the returning water’s temperature and protects the boiler from fIue-gas condensation and thermal shock. If every zone in a one-pipe, primary-secondary system should call at the same time, however unlikely this might be, the primary circuit’s temperature will drop by its full design temperature drop. In large commercial systems, this can lower the supply water temperature to the secondary circuits at the end of your primary loop. To get around this potential problem, you can use two-pipe, primary-secondary pumping instead. With this system, you pipe the primary circuit as a two-pipe direct- or reverse-return system. This gives you a way of delivering the same water temperature to each secondary circuit. You make your connection from the primary to the secondary circuit from a crossover “tunnel” that drops below the level of the primary supply and return mains. The drop in the pipe makes it easier to get rid of the air.
16
technical tips
Now, imagine yourself as the water in that primary main, What would you do? If the secondary circuit’s circulator were off, wouldn’t you choose to flow straight across those 12 inches of straight pipe? I know I would. That’s the path of least resistance. This is why that 12-inch maximum spacing is so important. If you place the tees too far apart, primary water will begin to see the secondary circuit as a path of lesser resistance and begin to flow that way.
tank. That way, you can take advantage of the primary circulator’s full differential pressure. This makes it much easier for you to get rid of any system air that works its way into the piping. Oh, and if you put full-port ball valves in the common piping between the primary and secondary circuits, you’ll be able to get the air out of the system a lot quicker as well.
technical information
Primary-secondary pumping lets you use small, inline circulators - even on large commercial jobs - and that’s a real plus. And in a multiple-boiler system, this simple method of piping gives you a way to lower boiler standby losses and save fuel. When piped properly, no water will flow through an “off” boiler when its secondary circulator stops. And when the water stops flowing, the standby losses practically disappear.
Primary-Secondary Pumping
Balancing is more of a challenge in a two-pipe, primary-secondary system. You have to look carefully at the flow rate needs of each circuit and “tunnel” and make sure you’re delivering the right flow to those time secondary circuits. This type of system usually calls for some thoughtful engineering, so take you time.
F.W. Webb Company
273 3/24/08 4:30:28 PM
Replacing a Steam-Heating Boiler HOW TO REPLACE AN OLD STEAM-HEATING BOILER Here are some tips that I thought you might want to file away somewhere for the next time you encounter an old steam heating boiler. Base the size of the replacement boiler on the connected load, not the building’s heat loss. The boiler’s ability to produce steam must match the system’s ability to condense steam. It really doesn’t matter what the building’s heat loss is. The radiators and pipes are going to condense steam at a certain rate, and if the boiler is too small (which usually happens if you size it based on the heat loss), the steam will go just so far. You’ll wind up with a building that has either hot rooms or cold rooms, and there’s not much you can do to cure the problem at that point.
If the boiler goes back to the Coal Era, know that it may be 75 percent larger than it has to be. It was standard to increase the boiler by that much in the old days because engineers weren’t certain the owners could make proper coal fires. By oversizing, they pretty much guaranteed there would be enough heat – even with lousy firemen. A contractor friend regularly measures the radiation and comes up with steam boilers of, say, 60 horsepower where 100 horsepower boilers are already on the jobs. The smaller boilers work beautifully. Never base the size of a replacement steam boiler on the old boiler’s rating. Survey those radiators. It’s the only way to be certain. Be aware of water levels. This is more important in gravity-return systems than it is in pumped-return systems. If the new boiler’s water level is too high, there may not be enough vertical space between the boiler water line and the end of the steam main (in one-pipe systems), or the lowest steam trap (in two-pipe, gravity-return systems). The result? Returning condensate backs
274 16_Troubleshooting_p295.indd 274-275
F.W. Webb Company
16
16
up into the mains causing water hammer. This usually happens in the middle of the steaming cycle. If the water level of the new boiler is too low, there’s a chance you may turn what was a wet return (a pipe below the boiler water line on a gravity-return system) into a dry return (a pipe that’s above the boiler water line). Here again, your reward for making this mistake is water hammer. If you find an old boiler that’s sitting up on a pedestal, know that it’s there to cover a return line on the building’s first floor. This was once a very common piping practice in apartment buildings. If you install your new boiler off the pedestal you’ll have to create a false water line to avoid water hammer. My book The Lost Art of Steam Heating goes into detail on how to make one of these wonderful devices. You can get a copy in the Books & More section. Check out the replacement boiler’s steaming capabilities. There are several things that make for a good steam boiler. First, if it’s a cast-iron boiler, the interior width of the sections should be as broad as possible. If it’s a steel fire-tube boiler, there should be plenty of space between the tubes. When water turns to steam inside a boiler the steam forms at the point of greatest heat. This is down there at the bottom of the boiler where the static pressure is also the greatest. As the steam bubbles break free from the metal and rise to the surface of the water, each bubble increases in size. If there’s not enough space for this to happen, the bubbles will crowd each other and create surging. It the sections are very narrow, or if the tubes are too close together, the water inside the boiler will fill with steam and become less dense than the water in the gauge glass or the pump controller’s water column. When the burner shuts off, the steam bubbles will suddenly condense. That can drop the water level in the boiler to a point lower than the level in the gauge glass or water column. The water level in the glass or column will then fall into the boiler. That makes the boiler-feed pump short-cycle and the low-water cutoff bounce on and off. Choose a boiler with lots of internal space.
Replacing a Steam-Heating Boiler
Compare the exit velocities of several boilers before you settle for one. The formula for figuring steam velocity is: Steam Velocity = Lbs./Hr X Cubic Volume of Steam (at the system’s pressure) 25 X Internal area of the steam nozzle Base the Lbs./Hr per hour on the Heating Capacity of the boiler. The rest you can get from a steam table and a good piping handbook. The lower the velocity, the drier the steam, and the better the steam boiler. Choose a boiler with the lowest possible exit velocity. Check the steaming rate of the boiler against the time lag of the system. A replacement steam boiler will usually hold less water than the old boiler. Because of this, you may not be able to use that new boiler on a gravity-return system without adding a boiler feed pump (and a false water line). If the job has a condensate pump, you may have to switch over to a boiler feed pump. The only way to know for sure is to find out how much water is in the operating range of the replacement boiler. That’s the vertical space between the center of the gauge glass and the low-water cutoff point. You’ll probably have to ask the boiler manufacturer for this information since few publish it. Once you get it, know that all boilers, regardless of size or type, steam at a constant rate of _ gpm/1,000 sq. ft. EDR (one sq. ft. EDR equals 240,000 BTUH in steam heating work). Now that you know how much water is in the operating range of that new boiler, and since you know its D.O.E. Heating Capacity, you can figure out how long it will fun before it shuts down on low water.
Next, time the lag between steaming and return. Run the old boiler begin timing when the header gets hot. Find how long it takes for the steam to work its way around the system condensate. In a gravity-return system, feel the end of the furthest main and stop timing when it gets hot. In a system with a condensation pump, you’ll stop timing when the pump starts for the first time. Be aware that clogged returns, missing air vents, and poorly pitched pipes can affect a stem’s time lag. If you don’t have enough water in the boiler’s operating range to satisfy the system time lag, you’ll need a boiler feed pump (and a false water line). If the old boiler isn’t operating, you won’t be able to time the lag. At that point, you’ll be making an educated guess, and this is where steam heating crosses the line between science and art, which is why I called my book The Lost Art of Steam Heating. Get yourself a copy at Books & More! Use the boiler manufacturer’s near-boiler piping diagrams. Nowadays, you have to consider near-boiler piping to be a part of the boiler because manufacturers depend on it to act as a separator for carry-over water. Check out the directions in their manuals and follow them exactly. Also, read what the manufacturer has to say about cleaning the boiler system and follow that as well.
Look, too, for a boiler that has as much vertical space as possible between the center of the gauge glass and the steam outlet. Boilers with top outlets generally produce drier steam than boilers with side outlets. You want that outlet to be as far away as possible from the surface of the water to avoid carryover. A sectional cast-iron boiler is less susceptible to changes in boiler water level than a steel, horizontal-fire-tube boiler because of the difference in shape. When the water rises a few inches in a round, horizontal boiler, the steaming space gets smaller because the water is reaching the top of a circle. In a cast-iron, sectional boiler, this doesn’t happen because the water is rising to the top of a rectangle rather than a circle.
www.fwwebb.com
16
technical tips
If you find the building is over-radiated, consider removing radiators, or better yet, use thermostatic radiator valves at the existing radiators. Don’t downsize the boiler figuring each radiator will get “half-hot.” What will actually happen is that a portion of the radiators in the building will get fully hot while the others stay stone cold.
SECTION
technical information
Go from room to room and survey the radiators. Then use a suitable pick-up factor for the piping. If you look in a boiler manufacturer’s catalog you’ll see they’ve already built in a pick-up factor. It’s the difference between the Net load and the D.O.E Heating Capacity load. It’s standard to increase the Net load by a factor of 1.33 nowadays to get to the Heating Capacity. If you notice that radiation is missing from the building, though, or if you see there’s no insulation on the pipes, the piping pick-up may be more than you expect. In cases such as these, protect yourself by using a larger pick-up factor. Measure the radiation and multiply it by a factor of 1.5. Then select the boiler from the D.O.E. Heating Capacity column, not the Net column. You’ll be glad you did this when that boiler starts for the first time.
SECTION
The F.W. Webb Heating Catalog
F.W. Webb Company
275 3/24/08 4:30:29 PM
Converting from Steam to Hot Water CONVERTING FROM STEAM TO HOT WATER HEAT? First things first. Before the 1920s, most steam contractors used cast-iron, column-type radiators. Those are the freestanding ones with the real wide sections. Column radiators were perfect for steam heating because they had a lot of internal space and they allowed the steam to rise up and displace the heavier air In the case of one-pipe steam, the air worked its way out of the radiator air vent. With two-pipe, the air escaped through the steam trap (or that old Vapor gizmo) and left the system through a vent somewhere down the main. Having a radiator with lots of internal space also allowed room for the condensate to get out of the way of the steam.
And that next step is to check to see if your system is one-pipe steam or two-pipe steam. This may seem like an easy thing to do, but don’t go by just one or two radiators. Many systems have a combination of both one- and two-pipe radiators, and that’s perfectly normal - for steam. Look it over. While it’s possible to convert a one-pipe radiator to hot water, it’s sometimes not practical. You have to run a second pipe from the top of each radiator back to the boiler. Some folks use radiant-floor tubing to do this. They drill and tap the top of the radiator section that’s opposite the supply valve and then run either PEX tubing or rubber hose back to the boiler, connecting it to the mains with cable ties as they go. Once back in the boiler room, they use manifolds with individual circuit-balancing valves to make their return connection to the boiler. Most plumbing & heating supply houses sell this gear nowadays.
276 16_Troubleshooting_p295.indd 276-277
F.W. Webb Company
16
16
A conversion from two-pipe steam to hot water is usually easier to do, but examine the system carefully before you make a decision. Many of the older two-pipe systems were Vapor systems. There may be orifices in either the supply valves or the return elbows. Those radiator return elbows may also have tiny check valves or stainless-steel balls that can mess up the flow if you don’t know they’re there. Look the job over carefully and if you have any doubts, go to the Wall and ask for help. Before you break out the tools, do a complete and accurate heat loss calculation on the entire building. Don’t settle for one of those cockamamie rules of thumb that has you measuring the cube of the building and multiplying by an arbitrary number. Rule-of-thumb methods will oversize your system by a ridiculous amount. Take the time to do it right. If you don’t know how to do a heat-loss calculation, check out the Quick Sizing Forms available from The Hydronics Institute (http://www.gamanet.org/ publist/hydroordr.htm) Once you get an accurate heat loss calculation, measure the existing radiation for square footage of Equivalent Direct Radiation (EDR). You’re trying to find out if the radiation that’s already in the building will be able to heat the place once the relatively cooler hot water is flowing through it. Keep in mind that one-psi steam in a radiator will bring the surface of that radiator up to 215 degrees. Hot water, by comparison, is usually only about 180 degrees, tops. A square foot of steam EDR will put out 240 Btuh. Convert that radiator to hot water and you’re only going to get about 150 Btuh out of that same square foot of radiation. So, for instance, if you have a five-tube, 26” high, 10-section, cast-iron radiator running on steam, it will emit 8,400 Btuh. Convert the system to 180degree hot water and you’ll get only 5,250 Btuh out of that radiator. If you’re looking for a fast way to figure out how much EDR is in a radiator, get a copy of my book, The Golden Rules of Hydronic Heating, which you’ll find in the Books & More section. Once you’ve gone through that exercise, ask yourself if this lesser output from the radiators will be enough to heat each room on the coldest day of the year. This depends on the heat loss and that’s why you have to take the time to do both an accurate heat loss calculation AND a survey of the existing radiation. It after you’ve done your homework, you find the existing radiation can carry the heat loss on the coldest day of the year, you can move on to the next step.
Converting from Steam to Hot Water
Check the system for leaks. Keep in mind a steam system is used to seeing only about two-psi steam pressure. If there are leaks anywhere, you might not have noticed them at such a low pressure. This is especially true if the leaks are in the return lines. But when you fill the system with water the static pressure is going to be a lot higher. You’ll notice those leaks for sure! It’s so much better to find them before the conversion, if you can. A two-story hot water system will have at least 12-psi static pressure on it. A three-story building will have 18-psi pressure, and so on. Add in the pump’s pressure along with the pressure of the expanding water as it heats and you can see the dramatic difference between steam and hot water. So before you commit to the job, raise the steam pressure to about 10-psi pressure and walk through the entire system looking for leaks. If they’re there, they should show up under the increased steam pressure. Once you see them, you’ll have a better idea at what you’re up against, and you’ll be able to make the decision as to whether or not you should move on from here. Next, if the system looks sound, you can take out the tools and go to work. You’ll have to remove the innards from all the thermostatic radiator traps and float & thermostatic traps near the ends of the main (if you have them) so the water will be able to flow freely. Again, be especially aware of any old Vapor equipment. There’s a big difference in size between the supply and return lines in a steam system so balancing will always be a challenge when you’re running on hot water. Leave the old radiator supply valves in place if they’re working. You’ll be able to use them for balancing the flow and the heat once you have the system up and running. Most two-pipe steam systems are similar to two-pipe, direct-return hot water systems. The big difference is that, unlike a hot water system, the return line doesn’t increase much in size as it returns to the boiler. With steam, the lines are picking up condensate, not the much greater flow at water you expect to see in a hot water system. Because of this, you may have to redo the return lines to accommodate the greater flow you’ll be seeing once you’ve converted the system. Are you beginning to see why I prefer to fix old steam systems rather than convert them to hot water? The good news, however, is that each two-pipe radiator will have a return that’s at least 1/2” in size. A 1/2” line can safely carry 1-1/2 gpm of hot water and that translates to about 15,000 BTUH, which is usually more than the typical radiator will need to put out to heat the average room.
www.fwwebb.com
The F.W. Webb Heating Catalog
If you’re going to keep the old boiler, you’ll have to change the trim, get getting rid of the gauge glass, the low-water cut-off, pressuretrol and near-boiler piping. If you’re replacing the boiler, you’ll still be getting rid of the existing near-boiler piping and setting the boiler up as you normally would with a hot water system. If you’re not sure how to do this, get a copy of Pumping Away, which is also in the Books & More section of www.HeatingHelp.com. Size your circulator based on your heat loss calculation, not on the existing radiation. Take your gross BTUH load and divide by 10,000 to get the GPM for the pump. To figure pump head, measure the longest piping run, from the boiler to the furthest radiator and back. Allow six feet of pump head for each 100 feet of piping in that longest run. That’s a rule of thumb, but it works well.
Use a good air separator. Every hot water system needs a good air separator. Sizing the compression tank is tricky because there’s going to be so much water in those old steam pipes than you’d expect to find in hot water system of the same BTUH rating. This is important because you base the size of the compression tank on the system’s total water volume. Figure out how much water you have in the system, and then talk with the compression tanks. Don’t depend on their quick-sizing charts in this case. They base those charts on standard systems, not steam conversions. You’ll have to get a count on how many feet of each size pipe you have in the system to estimate the total water volume. Here’s a chart that will help you figure out how much water you can expect to find in each foot of pipe:
Pipe
Gallons in each linear foot
1/2”
016
3/4”
.028
1”
.045
11/4”
.078
11/2”
.106
2”
.170
21/2”
.250
3”
.380
4”
.660
5”
1.040
6”
1.500
16
technical tips
After the 1920s, steamfitters began using cast-iron, tube-type radiators (the ones with the thin sections). These were actually hot water radiators, but they also worked well on steam systems. Building owners preferred them because they were nicer to look at. Tube-type radiators do have push nipples across the top of the sections, so if that’s what you have, you can move on to the next step.
SECTION
technical information
The trouble with those old column radiators, though, is that their makers never intended for them to be used with hot water. Those individual radiator sections aren’t connected across the top, and that presents a challenge with water. You have to look real close to notice this on those old radiators, and it’s the very first thing you should look for when you’re considering a conversion from steam to hot water. If you don’t see those top push nipples, the conversion isn’t going to be very easy - or practical. Water won’t flow well through a sectional radiator that’s not connected across the top. To make it work, you’d have t0 drill and tap each section and install air vents all the way across the top. Or, if you have a LOT of patience, you can wait for the system water to absorb the air and move it to the air separator. This could take months.
SECTION
If you’ve gotten this far, the next question will be, How do I control this hybrid I just created? The best way I know is to run the system on continuos circulator with an outdoor-air rest controller, It costs a bit more to set it up this way, but it is by far the best way I know to operate any hot water system, be it old or new.
F.W. Webb Company
277 3/24/08 4:30:29 PM
Technical Information
SECTION
SECTION
16
16
Technical Information
SR501 Switching Relay Wiring
THERMOSTAT
THERMOSTAT
T
T
R W T T
COM
R W T T
SR501 1 ZONE SWITCHING RELAY
24 VAC COM
POWER T STAT
H
R W T T
WHITE 120 VAC INPUT BLACK
24 VAC COM
4 4 6 6 5 N H 3 N/O N/C N/C N/O
T
T
T
24 VAC
T T ZONE 1
24 VAC
T T ZONE 2
T T ZONE 3
T T ZONE 4
T STAT 1 VALVE 1 T STAT 2 VALVE 2 T STAT 3 VALVE 3 T STAT 4 VALVE 4 T STAT 5 VALVE 5 POWER
T T ZONE 5
ZVC 405 FIVE ZONE ZONE VALE CONTROL
ZONE 1 1 2 3 4
N/O COM N/C
ZONE 2 1 2 3 4
ZONE 3 1 2 3 4
ZONE 4 1 2 3 4
ZONE 5 1 2 3 4
4 4 6 6 5 N H 3 N/O N/C N/C N/O JUMPER 3&4 TO BOILER AQUASTAT RELAY
JUMPER
JUMPER TO: TT ON BOILER
TO: ZC TO: ZR
H N
CIRCULATOR
TO: TT ON BOILER TO: 120 VAC POWER
SYSTEM PUMP
TO: 120 VAC POWER
REMOVE JUMPER. DO NOT CONNECT POWER TO N AND H TERMINALS.
T STAT LIGHT WILL GO * ON AND OFF WITH 24 VAC SIGNAL. POWER LIGHT WILL ALWAYS BE OFF.
SYSTEM PUMP AND BOILER TURN ON WHEN ANY ZONE VALVE OPENS.
Priority Zoning Circulator Controlling SR504/506 Switching Relay
ZVC404/406 with System Pump THERMOSTAT
THERMOSTAT
THERMOSTAT
T
T
T
N
PRIORITY OFF
BOILER 3 4
ON
H
PRIORITY POWER IN PR-IN PR-OUT LIVE NEUT
24 VAC MODE
120 VAC INPUT
ZONE 6 PRIORITY
NORMAL RESET
OFF ON
T T ZONE 1
24 VAC
FUSE (7 AMP MAX)
WHITE 120 VAC INPUT BLACK
FACTORY INSTALLED TRANSFORMER
A AQUASTAT ON DHW HEATER
PRIORITY OFF
T
SR 506
ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6
X X END SWITCH
SIX ZONE SWITCHING RELAY WITH OPTIONAL PRIORITY
ZC ZR
ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6
120 VOLT CIRCULATORS
POWER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6
N/O COM N/C ZONE 6 RELAY
T T ZONE 4
T T ZONE 5
T T ZONE 6
ZVC 406
ZONE 1 1 2 3 4
ZONE 2 1 2 3 4
ZONE 3 1 2 3 4
ZONE 4 1 2 3 4
ZONE 5 1 2 3 4
JUMPER 3&4
ZONE 6 1 2 3 4
120 VAC INPUT
JUMPER 3&4
TO BOILER AQUASTAT RELAY
POWER INPUT
FUSE 1 AMP
REMOVE JUMPER
EXTRA END SWITCH
T T ZONE 3
T STAT 1 VALVE 1 T STAT 2 VALVE 2 T STAT 3 VALVE 3 T STAT 4 VALVE 4 T STAT 5 VALVE 5 T STAT 6 VALVE 6 POWER
OFF
120V RELAY
24 VAC POWER
MAIN END SWITCH
ZONE 6 PRIORITY ON
T T ZONE 2
FIVE ZONE ZONE VALE CONTROL WITH OPTIONAL PRIORITY
THERMOSTATS
SLAVE
A
24 VAC
POWER IN
THERMOSTAT 1 2
WHITE 120 VAC INPUT BLACK
technical tips
PRIORITY ON
FACTORY INSTALLED TRANSFORMER
MASTER PRIORITY ZONING CIRCULATOR
MOTOR END SWITCH
TACO 4 WIRE ZONE VALVE 3 WIRE ZONE VALVE (POWER OPEN, SELF CLOSING)
2 WIRE ZONE VALVE (NO END SWITCH)
CIRCULATOR
CIRCULATOR
TO: 120 VAC POWER
1 2 3
BOILER
16 technical information
4 4 6 6 5 N H 3 N/O N/C N/C N/O
THERMOSTAT
24 VAC
END SWITCH
120 VAC INPUT
THERMOSTAT
POWER T STAT
POWER T STAT
120 VAC INPUT
THERMOSTAT
POWER IN
SR501 1 ZONE SWITCHING RELAY
24 VAC
WHITE 120 VAC INPUT BLACK
N 24 VAC SIGNAL
FACTORY INSTALLED TRANSFORMER
ALTERNATIVE WIRING (24 VAC POWERED INPUT SIGNAL)
FUSE (5 AMP MAX)
SR501 1 ZONE SWITCHING RELAY
ALTERNATIVE WIRING (TANKLESS COIL)
FACTORY INSTALLED TRANSFORMER
TYPICAL WIRING (COLD START)
ZVC403/405 with System Pump
DRY CONTACTS
BOILER
H N
SYSTEM PUMP
TO: “TT” ON BOILER
2 WIRE ZONE VALVE (NO END SWITCH)
1 2 3
TACO 3 WIRE ZONE VALVE
MOTOR END SWITCH
PRIORITY ZONE
SEE NOTE
4 WIRE ZONE VALVE (POWER OPEN, SELF CLOSING)
BOILER SYSTEM PUMP AND BOILER TURN ON WHEN ANY ZONE VALVE OPENS.
278 16_Troubleshooting_p295.indd 278-279
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
NOTE: WHEN A CIRCULATOR IS USED ON THE PRIORITY ZONE INSTEAD OF A ZONE VALVE, JUMPER 3 AND 4 OF THE PRIORITY ZONE.
F.W. Webb Company
279 3/24/08 4:30:31 PM
Technical Information SR501 Switching Relay
THERMOSTAT
TYPICAL WIRING
SECTION
SECTION
16
16
SR504 & SR506 Switching Relay
THERMOSTAT
ALTERNATIVE WIRING
SR501 1 ZONE SWITCHING RELAY
R W T T
THERMOSTATS
COLD START BOILER APPLICATION
SR501 1 ZONE SWITCHING RELAY
24 VAC
Technical Information
R W T T
COM
24 VAC
SR 506
COM
ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6
ZONE 6 PRIORITY ON OFF
SIX ZONE SWITCHING RELAY WITH OPTIONAL PRIORITY
120V RELAY
POWER T STAT
POWER T STAT
ZC
ZR
ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6
120 VOLT CIRUCULATORS
POWER INPUT
4 4 6 6 5 N H 3 N/O N/C N/C N/O
4 4 6 6 5 N H 3 N/O N/C N/C N/O
TO: “TT” ON BOILER
SR 506 POWER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6
ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6
ZONE 6 PRIORITY ON OFF
SIX ZONE SWITCHING RELAY WITH OPTIONAL PRIORITY
120V RELAY 24 VAC POWER
X X END SWITCH
ZC
ZR
ZONE1 ZONE2 ZONE3 ZONE4 ZONE5 ZONE6
120 VOLT CIRUCULATORS
POWER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6
POWER INPUT
JUMPER
TO: “ZC” ON AQUASTAT 120 VAC INPUT
TO: “ZR” ON AQUASTAT
120 VAC INPUT
JUMPER TO: TT ON BOILER
TO: ZC TO: ZR TO: 120 VAC POWER
CIRCULATOR
CIRCULATOR
SR504 & SR506 Switching Relay THERMOSTATS
THERMOSTATS
TANKLESS COIL BOILER APPLICATION
24 VAC POWER
technical tips
COLD START BOILER APPLICATION
24 VAC POWER
SR503
SR503
ZONE1 ZONE2 ZONE3
ZONE1 ZONE2 ZONE3
THREE ZONE SWITCH RELAY WITH OPTIONAL PRIORITY FUSE 1 AMP
N
P
ZC
THREE ZONE SWITCH RELAY WITH OPTIONAL PRIORITY POWER ZONE 1 ZONE 2 ZONE 3
H
X2 X1 ZR ZONE1 ZONE2 ZONE3
FUSE 1 AMP
N
JUMPERS
ZC
H
X2 X1 ZR ZONE1 ZONE2 ZONE3
TO: 120 VAC POWER (NEUTRAL)
TO: 120 VAC POWER (HOT)
TO: 120 VAC POWER (HOT)
TO: “TT” ON AQUASTAT CONTROL
120 VOLT CIRCULATORS
TO: “TT” ON AQUASTAT CONTROL
16_Troubleshooting_p295.indd 280-281
P
POWER ZONE 1 ZONE 2 ZONE 3
JUMPERS
TO: 120 VAC POWER (NEUTRAL)
280
16
FUSE 1 AMP
technical information
120 VAC INPUT
TO: 120 VAC POWER
X X END SWITCH
FUSE 1 AMP
120 VAC INPUT
JUMPER
24 VAC POWER
THERMOSTATS
TANKLESS COIL BOILER APPLICATION
F.W. Webb Company
TO: “ZC” ON AQUASTAT CONTROL
120 VOLT CIRCULATORS
TO: “ZR” ON AQUASTAT CONTROL
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
281 3/24/08 4:30:32 PM
Expansion Tank Cross Reference
SECTION
SECTION
16
16
flexcon
vent-rite
amtrol
watts
state
elbi
B&G
sparco
HT-15
VR-15-FG
15
ET-15
ET-2
XT-15
HFT-15
TK3000-15
HT-30
VR-30-FG
30
ET-30
ET-5
XT-30
HFT-30
TK3000-30
HT-60
VR-60-FG
60
ET-60
ET-7
XT-60
HFT-60
TK3000-60
HT-90
VR-90-FG
90
ET-90
ET-14
XT-90
HFT-90
TK3000-90
SXHT-30
SXVR-30-FG
SX-30
NA
ET-15
XTV-30
HFT-30V
XPS-30
SXHT-40
SXVR-40-FG
SX-40
NA
ET-20
XTV-40
HFT-40V
XPS-40
SXHT-60
SXVR-60-FG
SX-60
NA
ET-36
XTV-60
HFT-60V
XPS-60
SXHT-90
SXVR-90-FG
SX-90
NA
ET-52
XTV-90
HFT-90V
XPS-90
SXHT-110
SXVR-110-FG
SX-110
NA
ET-86
XTV-110
HFT-110V
XPS-110
SXHT-160
SXVR-160-FG
SX-160
NA
ET-96
XTV-160
HFT-160V
XPS-160
282 16_Troubleshooting_p295.indd 282-283
Allanson beckett carlin france sid harvey webster 2275-456 2275U 51828U 41000-SO-AR 10SAY-56 T87E 3-24AB-AER 2275-605 2275U 51824U 41000-SO-BK2 10SAY-05 T90E 3-28AB-BS 2275-458 51805U — — — 3-32AB-BAF 2275-628G 2275U 51771U 41000-SO-BK1 10SAY-04 T92E (1) 3-28AB-BAFR 2275-630 2275U 51840U 41000-SO-SC 10SAY-16 T-95E 313-24AB81 2275-630 2275U
51826U
41000-SO-CAS 10SAY-15
T94E
313-28AB85
2275-633 2275U 2275-653 2275U 2275-619 2275U
51880U 51837U 51825U
41000-SO-LC — 41000-SO-WM 10SAY-32 41000-SO-WA3 10SAY-03
— T96E T93E
12-8AB7 — 313-28AB91
41000-SO-WA2 10SAY-30 41000-SO-WA1 10SAY-31 41000-SO-KIT 10SAY-KIT
T-88E T89-10E T97K
313-25AB78 313-28AB205 —
2275-620 2275U 51827U 2275-647 2275U 51836U 2275-KIT1 2275U 51835
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
Sid Harvey
Thermolok
T-84 T-86 T-34-B T-31N T37
C-792 TSR-10 C-793 C-53 TA-10
T-183B T-80-3M T-92
C-483
T-90 T-95 T-94
TB-11 TC-11 TC-10
T-265 T-28B T-120 T-122 T-29-10B
C-823 C-544 C-794 C-807 C-733
T-88 T-93
C-799 TW-10
T-31N T-18N T-17N
C-456 C-551 C-554
T17M T-21N T1-15
TB-10
16
C-555
cross reference
BURNER & transformer brand AERO BECKETT S BECKETT AFII BECKETT A, AF, AFG CARLIN 17.5, 200, 201 500, 501, CRD CARLIN 99, 100 101, CRD CARLIN 601 & UP WEIL McLAIN WAYNE HI SPEED M/MH WAYNE E WAYNE HS Ignitor Kit
BURNER MFR Allanson Dongan France Webster 10,000 Volt Secondary Mid Point Ground ABC 2721-411 XD-AB207 5LAY-20 313-25AB59 XD-AB201 5LAY-02 313-25AB86 ABC/SUNRAY 2721-631A A10-SV351 LKR-2 313-25AB73 ABC-CRANE 2721-409 313-25AB65 ABC-D&LC 2721-452 ACME/QUIET HEET 421-104 A10-SR12 LGNV ACME-WEATHERALL 2721-457 5LAY-11 3-25AB-AH XD-AR211 5LAY-56 3-24XAB-AER AERO 2721-456 ARCO/AMER.STANDARD 421-216 LGNV ARCO/AMER.STANDARD 421-557 A10-SP18 LGHW 312-26ABE23 312-25ABE1 ARMSTRONG/ESSO 421-340 LGPW-2 BECKETT A, AF 2721-628 XD-BK103 5LAY-04 3-28AB-BAF BECKETT AFG 2721-628G BECKETT AFII 2721-658 3-32AB-BAF BECKETT S 2721-605 XD-BK204 5LAY-05 3-28AB-BS CARLIIN 200 201 500 CRD 2721-629 XD-CR206 5LAY-16 313-24AB81 CARLIN 100 CRD 2721-630 XD-CR205 5LAY-15 313-28AB85 CLEAN BURN 2721-654 5LAY59 CLEAVER BROOKS 421-659 312-8AO97 DUCANE 421-430 A10-SQ182 5LAY-06 313-25AB90 GORDON PIATT 421-661 313-25AB100 JOHN WOOD 2721-069 LENNOX 421-331 XD-DC212 313-25AB62 METAL MASTER 421-262 A10-S32 LGM NU-WAY (LARGE PLATE) 2721-448 313-24AB80 NU-WAY (SMALL PLATE) 2721-572 313-24AB82 SUNRAY 421-104E 312-26AB022 WAYNE (BLUE ANGEL) 2721-647 5LAY-31 313-28AB205W WAYNE E 2721-620 XD-WN208 5LAY-30 313-25AB78 WAYNE HI SPEED M MH 2721-619 XD-WN202 5LAY-03 313-28AB91 12,000 Volt Secondary Mid Point Ground CARLIN 2714-633 A12-SV10 2KACVS-2 12-8AB7 CLEAVER BROOKS 2714-359 A12-SJ10 2KAAVS-1 12-8AO8 BECKETT 2714-656 GORDON PIATT 2714-662 12-8AB02 10,000 Volt Secondary Mid Point Ground UNIVERSAL 6 WAY 421-BT053 312-24ABE203 421-BT104 A10-SR10 LGCV 312-24AB0237 A10-SX10 LGDW 312-24ABE202 421-BT240 A10-SW10 LGEV 312-25AB0237 421-BT276 A10-SQ10 LGDV 312-24AB0202 421-BT290 A10-SJ10 LFBV 312-25AB0202 421-BT299 A10-SV10 LGFV 312-25ABE0202 421-BT332 A10-SF10 LFAV 312-24A0202 421-BT387 LAUV 312-25AX0600 421-BT636 INDUSTRIAL TYPE IGNITION TRANSFORMERS 6,000 Volt Secondary One End Ground 120 Volt GAS APPLICATION 1092-F A06-SA6 6EEGW-2 612-6A7 10,000 Volt Secondary One End Ground 120 Volt OIL APPLICATION 542-A 312-6A0456
technical information
Electronic Transformer Cross Reference
Transformer
T-628
T-246N
F.W. Webb Company
283 3/24/08 4:30:32 PM
Technical Information
SECTION
SECTION
16
16
Technical Information
Gas Valves Selection Guide TRADE REPLACEMENTS (Double-Check Specifications Before Replacement)
Universal Service Part
Direct Service Part Replacement VR8300A4508
VR8300A4516
VR8300A3500
Before Replacement)
SPECIFICATIONS
ACCESSORIES
ACCESSORIES
Includes Includes OpeningService Inlet/Outlet Opening Temperature Universal Direct Service Pressure Part Regulator Inlet/Outlet Pressure Regulator Temperature Characteristics Characteristics Q340 3/4" x 1/2" Natural to LP Q340 3/4" Straight 3/4" x 1/2" 1/2" Natural x 3/8" to LP Remote 3/4"Rod Straight Part Size (in.) ReplacementSetting(standard, (psi) Size (in.) Setting (psi) Range (standard, step) step) Range Thermocouple Reducer Bushing Conversion Kit ThermocoupleFlange Reducer BushingReducer Conversion BushingKit Adapter Flange Standard
Standard VR8300A4516
3/4 x 3/4 VR8300A4508 3.5 in. wc (0.87Standard kPa)
0˚ to 175˚ F 3/4 x 3/4 (-18˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) Two
0˚ to 175˚ F One (-18˚ to 79˚ C)
None
None
Two
NoneOne
COMPETITIVE REPLACEMENT Honeywell Remote Rod 1/2" x 3/8" Reducer Bushing Adapter
Honeywell White-Rodgers
VR8300A4003, VR8300A4011, VR8300A4037, None None VR8300A4045, VR8300A4557, VR8300A4565
VR8300A4003, VR8300A4011, VR8300A4037, 36C01-405 VR8300A4045, VR8300A4557, VR8300A4565 VR8300A3104, VR8300A3120, VR8300A3153, VR8300A3161, 36C03-300,VR8300A3203, 36C03-400, 36C03-433, VR8300A3559, 36C03-258 VR8300A3567, VR8300A3575
1/2 x 3/4 VR8300A3500 3.5 in. wc (0.87Standard kPa)
0˚ to 175˚ F 1/2 x 3/4 (-18˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) One
0˚ to 175˚ F One (-18˚ to 79˚ C)
None
None
One
NoneOne
NoneNone
VR8300A3104, VR8300A3120, VR8300A3153, VR8300A3161, None VR8300A3203, VR8300A3559, None VR8300A3567, VR8300A3575
Standard
3/4 x 3/4 VR8300A4516 3.5 in. wc (0.87Standard kPa)
0˚ to 175˚ F 3/4 x 3/4 (-18˚ to 79˚ C)
One3.5 in. wc (0.87 kPa) Two
0˚ to 175˚ F One (-18˚ to 79˚ C)
One
None
Two
NoneOne
NoneNone
VR8300A4003, VR8300A4011, VR8300A4037, None None VR8300A4045, VR8300A4557, VR8300A4565
VR8300A4003, VR8300A4011, VR8300A4037, VR8300A4045, VR8300A4557, VR8300A4565
VR8204A2076
Standard
1/2 x 1/2 VR8204A2076 3.5 in. wc (0.87Standard kPa)
0˚ to 175˚ F 1/2 x 1/2 (-18˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) None
0˚ to 175˚ F One (-18˚ to 79˚ C)
None
One
None
OneOne
None One
VR8204A1201, VR8204A1219, VR8204A2001, One None VR8204A2175, VR8204A2803
VR8204A1201, VR8204A1219, VR8204A2001, VR8204A2175, VR8204A2803
VR8204M1091
Standard
1/2 x 1/2 VR8204M1091 3.5 in. wc (0.87Standard kPa)
-40˚ to 175˚ F 1/2 x 1/2 (-40˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) None
-40˚ to 175˚ F One (-40˚ to 79˚ C)
None
One
None
OneOne
None One
One VR8204M1075
None
36E01-204, 36E01-205, 36E01-206, VR8204M1075 36E01-305, 36E93-304
One
None
36G22-214
VR8245M2530 Standard
1/2 x 1/2 VR8205A2024 3.5 in. wc (0.87Standard kPa)
0˚ to 175˚ F 1/2 x 1/2 (-18˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) None
0˚ to 175˚ F One (-18˚ to 79˚ C)
None
One
None
OneOne
None One
VR8245M2530
Standard
1/2 x 1/2 VR8245M2530 3.5 in. wc (0.87Standard kPa)
-40˚˚ to 175˚˚ F 1/2 x 1/2 (-40˚˚ to 79˚˚ C)
None3.5 in. wc (0.87 kPa) None
-40˚˚ to 175˚˚ F One (-40˚˚ to 79˚˚ C)
None
None
None
OneOne
NoneNone
VR8205H1003
Slow
1/2 x 1/2 VR8205H1003 3.5 in. wc (0.87 kPa) Slow
0˚˚ to 175˚˚ F 1/2 x 1/2 (-18˚˚ to 79˚˚ C)
None3.5 in. wc (0.87 kPa) None
0˚˚ to 175˚˚ F None (-18˚˚ to 79˚˚ C)
None
None
None
None None
NoneNone
VR8305H4013, None VR8305H4039 None
VR8305H4013, VR8305H4039
3/4 x VR8304H4503 3/4 3.5 in. wc (0.87 kPa) Slow
0˚ to 175˚ F 3/4 x 3/4 (-18˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) None
0˚ to 175˚ F One (-18˚ to 79˚ C)
None
None
None
NoneOne
NoneNone
VR8204H1006, None VR8204H1055 None
VR8204H1006, VR8204H1055
3/4 x VR8345H4555 3/4 3.5 in. wc (0.87 kPa) Slow
-40˚ to 175˚ F 3/4 x 3/4 (-40˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) Two
-40˚ to 175˚ F One (-40˚ to 79˚ C)
None
None
Two
NoneOne
NoneNone
None
None
1/2 x 3/4 VR8304M3509 3.5 in. wc (0.87Standard kPa)
-40˚ to 175˚ F 1/2 x 3/4 (-40˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) One
-40˚ to 175˚ F One (-40˚ to 79˚ C)
None
None
One
NoneOne
NoneNone
None
None
3/4 x VR8304M4507 3/4 3.5 in. wc (0.87Standard kPa)
-40˚ to 175˚ F 3/4 x 3/4 (-40˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) Two
-40˚ to 175˚ F One (-40˚ to 79˚ C)
None
None
Two
NoneOne
NoneNone
None VR8304M4002
None
VR8304H4503
Slow VR8345H4555
VR8345H4555
Slow
VR8304M3509
Standard
VR8304M4507
VR8345M4302
Standard
VR8345M4302
VR8205M1106, VR8205M2310, VR8205M2443, One None VR8205M2450, VR8205M2476
36C01-405 720-406 (7200ER)
36C03-300, 36C03-400, 720-404 36C03-433, (7200ER) 36C03-258
700-400
VR8205M1106, VR8205M2310, VR8205M2443, 36E36-304, 36E22-214 VR8205M2450, VR8205M2476
722-051 (2000DERHC)
720-079 36E36-304, (7200IPER), 36E22-214 720-080 (7200IPER-LP)
36E98-304, 36E24-214, 36E52-214
36E98-304, 36E24-214, 700-052 36E52-214
-40˚ to 175˚ F One (-40˚ to 79˚ C)
None
One
One
NoneOne
None One
VR8345M4302
Standard
3/4 x VR8345M4302 3/4 3.5 in. wc (0.87Standard kPa)
-40˚ to 175˚ F 3/4 x 3/4 (-40˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) Two
-40˚ to 175˚ F One (-40˚ to 79˚ C)
None
None
Two
NoneOne
NoneNone
VR8205Q2555
2-Stage
1.7 in. wc Low Fire; 1/2 x VR8205Q2555 1/2 2-Stage 3.5 in. wc High Fire
-40˚ to 175˚ F 1/2 x 1/2 (-40˚ to 79˚ C)
1.7 in. wc Low Fire; None None 3.5 in. wc High Fire
-40˚ to 175˚ F One (-40˚ to 79˚ C)
None
None
None
OneOne
NoneNone
2-Stage
1.7 in. wc Low Fire; 3/4 x VR8304Q4511 3/4 2-Stage 3.5 in. wc High Fire
-40˚ to 175˚ F 3/4 x 3/4 (-40˚ to 79˚ C)
1.7 in. wc Low Fire; None Two 3.5 in. wc High Fire
-40˚ to 175˚ F One (-40˚ to 79˚ C)
None
None
Two
NoneOne
NoneNone
None
None
36C76-406, 36C76-420, 36C76-463
36C76-406, 36C76-420, 36C76-463 36D13-208, 36D13-405, 36G54-214
VR8345Q4563
VR8305M4066, VR8305M4165, 36G22-214, 36C68-423 VR8305M4231
None
1.7 in. wc Low Fire; 3/4 x VR8305Q4500 3/4 2-Stage 3.5 in. wc High Fire
-40˚ to 175˚ F 3/4 x 3/4 (-40˚ to 79˚ C)
1.7 in. wc Low Fire; None One 3.5 in. wc High Fire
-40˚ to 175˚ F One (-40˚ to 79˚ C)
None
None
One
NoneOne
NoneNone
None VR8305Q4146
None
36D13-208, VR8305Q4146 36D13-405, 36G54-214
VR8345Q4563
2-Stage
1.7 in. wc Low Fire; 3/4 x VR8345Q4563 3/4 2-Stage 3.5 in. wc High Fire
-40˚ to 175˚ F 3/4 x 3/4 (-40˚ to 79˚ C)
1.7 in. wc Low Fire; None Two 3.5 in. wc High Fire
-40˚ to 175˚ F One (-40˚ to 79˚ C)
None
None
Two
NoneOne
NoneNone
None
None
36E96-314
VR8200A2124
Standard
1/2 x 1/2 VR8200A2124 3.5 in. wc (0.87Standard kPa)
0˚ to 175˚ F 1/2 x 1/2 (-18˚ to 79˚ C)
One3.5 in. wc (0.87 kPa) None
0˚ to 175˚ F One (-18˚ to 79˚ C)
One
One
None
OneOne
None One
One
None
3.5 in. wc (0.87Standard kPa) 1/2 x 1/2 VR8200A2132
0˚ to 175˚ F 1/2 x 1/2 (-18˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) None
0˚ to 175˚ F One (-18˚ to 79˚ C)
None
VS820A1088
VR8200A2132
Standard VR8200A2744
One
None
OneOne
None One
One
None
One None + One Elbow
OneOne
One None + One Elbow
One VR8200A2322*
None
36E54-214
Standard
1/2 x 1/2 VR8200A2744 3.5 in. wc (0.87Standard kPa)
1˚ to 175˚ F 1/2 x 1/2 (-18˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) None
1˚ to 175˚ F One (-18˚ to 79˚ C)
None
VS820A1054
Standard
3/4 x 3/4 VS820A1054 3.5 in. wc (0.87Standard kPa)
32˚ to 175˚ F 3/4 x 3/4 (0˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) Two
32˚ to 175˚ F None (0˚ to 79˚ C)
None
None
Two
OneNone
NoneNone
VS820A1005, VS820A1013, VS820A1047, One None VS820A1278, VS820A5204, VS820A1922
VS820A1005, 36C03U-300, VS820A1013, 36C03U-333, VS820A1047, 36C03U-400, VS820A1278, VS820A5204, 36C03U-433 VS820A1922
VS820A1336
Standard VS820A1088
3/4 x 3/4 VS820A1336 10.0 in. wc (2.49Standard kPa)
32˚ to 175˚ F 3/4 x 3/4 (0˚ to 79˚ C)
10.0 in. wc (2.49 kPa) None Two
32˚ to 175˚ F None (0˚ to 79˚ C)
None
None
Two
OneNone
NoneNone
VS820A1211, VS820A1740, VS820A1120, One None VS820A1898, VS820A1872, VS820A1906
VS820A1211, VS820A1740, VS820A1120, VS820A1898, VS820A1872, VS820A1906
VS820A1088
Standard
3/4 x 3/4 VS820A1088 3.5 in. wc (0.87Standard kPa)
32˚ to 175˚ F 3/4 x 3/4 (0˚ to 79˚ C)
None3.5 in. wc (0.87 kPa) Two
32˚ to 175˚ F One (0˚ to 79˚ C)
None
None
Two
OneOne
Yes None
VS820A1807, VS820A2003, VS820A1815, One Yes VS820A1039, VS820A2011
VS820A1807, VS820A2003, VS820A1815, VS820A1039, VS820A2011
*Canadian Numbers
36E96-314 720-082 (7200IPER2-4)
720-082 (7200IPER2-4)
720-400 (7200ER), 720-402 (7200ER)
720-400 (7200ER), 720-402 (7200ER)
720-400 (7200ER), 720-402 (7200ER)
720-400 (7200ER), 720-402 (7200ER)
VR8200A2116, VR8200A2264, VR8200A2322*
VR8200A2744
VR8200A2322* 36C03U-300, 36C03U-333, 36C03U-400, 36C03U-433
*Canadian Numbers
cross reference
Notes: Notes: All piloted valves have a 1/4" compression fitting. All piloted valves have a 1/4" compression fitting. All the VR valves come set for natural gas, but can be converted All the to VRLP valves gas. come set for natural gas, but can be converted to LP gas. The VS820A1054 is for natural gas. The VS820A1336 is for TheLPVS820A1054 gas. is for natural gas. The VS820A1336 is for LP gas. All the VR valves have inlet and outlet pressure taps. The VS820 All the VR valves valves havehave justinlet an outlet and outlet pressure pressure tap. taps. The VS820 valves have just an outlet pressure tap.
720-051 (7200DER)
36E36-304, 36C68-423
VR8205Q2662, VR8205Q2746, VR8205Q2787, 36E54-214 VR8205Q2381
2-Stage
VR8200A2744
36G22-214, 720-051 36C68-423 (7200DER)
36E36-304, 36C68-423
VR8305Q4500
VR8200A2116, VR8200A2264, VR8200A2322*
700-052
VR8304M4002
None3.5 in. wc (0.87 kPa) One
VR8304Q4511
16
720-079 (7200IPER), 720-080 (7200IPER-LP)
720-070 (7200IPER-S7C), 720-071 (7200IPER-S7C), 720-072 720-070 (7200IPER-S7C), 720-071 (7200IPER-S7C), 720-072 (7200IPER-S7C), 720-073 (7200IPER-LP-S7C) (7200IPER-S7C), 720-073 (7200IPER-LP-S7C)
-40˚ to 175˚ F 1/2 x 3/4 (-40˚ to 79˚ C)
VR8345Q4563
700-400
36G22-214 722-051 (2000DERHC)
1/2 x 3/4 VR8305M3506 3.5 in. wc (0.87Standard kPa)
VR8205Q2662, VR8205Q2746, VR8205Q2787, One None VR8205Q2381
720-404 (7200ER)
722-079 (2000IPERHC)
Standard
None
720-406 (7200ER)
36E01-204, 36E01-205, 36E01-206, 722-079 (2000IPERHC) 36E01-305, 36E93-304
VR8305M3506
VR8305M4066, None VR8305M4165, VR8305M4231 None
Robertshaw
For a complete cross-reference, visit www.customer.honeywell.com
284 16_Troubleshooting_p295.indd 284-285
F.W. Webb Company
www.fwwebb.com
technical information
VR8205A2024
COMPETITIVE REPLACEMENT White-Rodgers Robertshaw
NoneNone
VR8300A4516
VR8245M2530
VR8345H4555
TRADE REPLACEMENTS (Double-Check Specifications SPECIFICATIONS
The F.W. Webb Heating Catalog
F.W. Webb Company
285 3/24/08 4:30:33 PM
SECTION
SECTION
16
16
Technical Information
Technical Information
SmartValve™ Control Systems Selection Guide SPECIFICATIONS
SPECIFICATIONS Includes
Ignition/Application
HSI Water Heaters
Universal Gas Type Ignition/Application Service Part
Opening Universal Characteristics Service Part
SV9570A2518
SV9570A2518
Natural
HSI Water Heaters SV9570A2526
Intermittent HSI Pilot with Combustion Air Control and Limit Monitoring Forced Air Furnace
Standard Opening LP
SV9541Q2561 Intermittent HSI Pilot
SV9570A2526
Ambient Temperature Gas Type Range
Natural 0˚ to 150˚ F (-18˚ to 66˚ C) LP
SV9541Q2561 2-Stage
SV9641M4510 Standard Opening
SV9510M2511
SV9510M2511
SV9520M2536
SV9520M2536
SV9510K2539
SV9510K2539 Slow Opening
SV9520H8513
SV9520H8513 Fast-Slow Opening
SV9601M4571
SV9601M4571
SV9501M2528
A.O. Smith
SV9570A2054, SV9570A2070, SV9570A2096
SV9570A2054, SV9570A2070, SV9570A2096
A.O. Smith
A.O. Smith
SV9570A2062, SV9570A2088, SV9570A2187
SV9570A2062, SV9570A2088, SV9570A2187
ICP, Heil, Tempstar, Arcoaire, Comfortmaker, KeepRite No ICP, Heil, Tempstar, Arcoaire, Comfortmaker, Two KeepRite, Mestek, Slant/Fin
ICP, Heil, Tempstar, Arcoaire, Comfortmaker, KeepRite
SV9540Q2464, SV9541Q3098
SV9540Q2464, SV9541Q3098
0˚ to 150˚ F None (-18˚ to 66˚ C)
A.O. Smith No
None -40˚ to 175˚ F (-40˚ to 79˚ C) Two
No
Yes
No
None
None No
Yes
Modine
Yes
-40˚ to 175˚ F (-40˚ to 79˚ C) None
Yes
No
Intermittent HSI Pilot, General Application
Intermittent HSI Pilot, Natural General Application SV9602P4816
SV9602P4816
SV9602P4824
SV9602P4824 Step Opening
SV9602P4832
SV9602P4832
SV9602P4840
SV9602P4840
SV9510M2347, SV9510M2362, SV9410M2902, SV9510M2347, SV9510M2412, SV9510M2362, SV9510M2354, SV9410M2902, SV9510M2412, SV9510M2354, SV9410M2910, SV9510M2388, SV9510M2420 SV9410M2910, SV9510M2388, SV9510M2420
0˚ to 175˚ F (-18˚ to 79˚ C)
Fast-Slow Opening
Roberts Gordon 0˚ to 175˚ F (-18˚ to 79˚ C)
Armstrong, Concord, AirEase
Two No
0˚ to 175˚ F (-18˚ to 79˚ C) Natural
Slow Opening
None
SV9501M8103
None
0˚ to 175˚ F (-18˚ to 79˚ C)
-40˚ to 175˚ F Two (-40˚ to 79˚ C)
Laars, Utica, Armstrong, Concord, AireEase
None
Yes
SV9501M8103
Yes
Burnham Step Opening None
ICP,SV9501M2056, Heil, Tempstar, SV9501M2080, Arcoaire, SV9501M2718, SV9501M2056, SV9501M2726, SV9501M2080, SV9501M2031, SV9501M2718, SV9501M2049, SV9501M2726, SV9501M2239, SV9501M2031, SV9501M2049, SV9501M2239, Comfortmaker, KeepRite SV9501M2700, SV9501M2734, SV9501M2742, SV9501M2700, SV9501M2064 SV9501M2734, SV9501M2742, SV9501M2064
Yes
Burnham, ICP, Heil, Tempstar, Arcoaire, Comfortmaker, KeepRite
-40˚ to 175˚ F (-40˚ to 79˚ C)
Armstrong, Concord, AirEaseSV9520H8042, SV9520H8034, SV9520H8067, SV9520H8026 SV9520H8042, SV9520H8034, SV9520H8067, SV9520H8026
SV9601M4167, SV9601M3003,SV9601M4225 SV9601M4167, SV9601M3003,SV9601M4225 No ICP, Heil, Tempstar, Arcoaire, Comfortmaker, KeepRite
-40˚ to 175˚ F (-40˚ to 79˚ C) Fast-Fast
Roberts GordonSV9510H2228, SV9510K2133, SV9510K2158, SV9510K2141, SV9510H2228,SV9510K2166 SV9510K2133, SV9510K2158, SV9510K2141, SV9510K2166
Two
Standard Opening -40˚ to 175˚ F (-40˚ to 79˚ C)
No
None
Slow Opening
SV9501M8129 Fast-Fast
SV9502H2522 Slow Opening
Modine
SV9420M2331, SV9520M2403, SV9420M2323 SV9420M2331, SV9520M2403, SV9420M2323
Yes SV9502H2522
16
ICP, Heil, Tempstar, Arcoaire, SV9541M2094, Comfortmaker,SV9540M2229, SV9540M2260, SV9541M2094, SV9640M4116, SV9540M2229, SV9640M4124, SV9540M2260, SV9640M4116, SV9640M4124, KeepRite, Mestek, Slant/FinSV9540M2278, SV9540M2245, SV9640M3126, SV9540M2278, SV9640M4132 SV9540M2245, SV9640M3126, SV9640M4132
Standard Opening -40˚ to 175˚ F (-40˚ to 79˚ C) Natural
Yes SV9501M8129
Replaces
Standard Opening No
Standard Opening Yes
Standard Opening SV9501M2528
Replaces
Opening Natural to LP Characteristics Conversion Kit
-40˚ to 175˚ F Natural (-40˚ to 79˚ C)
Direct Ignition, Natural General Application
OEM Brands
Includes
Ambient Temperature 3/4" x 1/2" ReducerNatural to LP 3/4" x 1/2" Reducer OEM Brands Extension Extension Range Bushings Conversion Kit Bushings Harness Harness
2-StageYes
Standard Opening
Direct Ignition, General Application
CROSS-REFERENCE
technical information
with Combustion Natural Air Control and Limit Monitoring Forced Air Furnace SV9641M4510
CROSS-REFERENCE
Laars, Utica,SV9501H3415, Armstrong, Concord, SV9501H2417, AireEase SV9501H2409, SV9502H1706, SV9501H3415,SV9502H2704, SV9501H2417,SV9501H3423, SV9501H2409,SV9501H2425 SV9502H1706, SV9502H2704, SV9501H3423, SV9501H2425 Burnham, ICP, Heil, Tempstar, Arcoaire, SV9501P2004, SV9601P4107, SV9501P2053, SV9502P2101, SV9501P2004,SV9602P4105 SV9601P4107, SV9501P2053, SV9502P2101, SV9602P4105 Comfortmaker, KeepRite Burnham
SV9501P2087, SV9601P4172, SV9502P2127, SV9602P4121 SV9501P2087, SV9601P4172, SV9502P2127, SV9602P4121
Yes
Two Burnham
SV9501P2020, SV9501P2046, SV9601P4149, SV9601P4164, SV9501P2020,SV9502P2119, SV9501P2046,SV9502P2135, SV9601P4149, SV9601P4164, SV9502P2119, SV9502P2135, Burnham SV9602P4113, SV9602P4139 SV9602P4113, SV9602P4139 SV9601P4115
SV9601P4115
cross reference
For a complete cross-reference, visit www.customer.honeywell.com
286 16_Troubleshooting_p295.indd 286-287
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
287 3/24/08 4:30:34 PM
Technical Information
SECTION
SECTION
16
16
Technical Information
Ignition Modules Selection Guide APPLICATIONS
Universal Service Part
Ignition System
Line Volt Hot Surface Ignition
S8910U1000
Universal Flame Service Sensor Part
1 or 2 Rods S8910U1000
APPLICATIONS
Ignition Ignition Trials Flame Sequence Ignition SystemTo Lockout Sensor (Note 1) (Note 1)
Line Volt Hot 1 or 3 P 1 or 2 Rods Surface Ignition Field Selectable
TIMINGS
Ignition Ignition Trial Time Sequence (Note 1)
4 sec. or 7 sec. P Field Selectable
Ignition Trials Between Trial To Lockout Time (Note 1)
96 1 orsec., 3 3Field TrialSelectable Mode Only
TIMINGS
Ignition Trial Pre-Purge Time
4 sec. or 7 sec. 32 sec. Field Selectable
Flame Between Failure Trial Response Time Time
96 sec., 1.5 sec. 3 Trial Mode Only
FEATURES AND FUNCTIONS
Type Pre-Purge of Gas
Nat or32LPsec.
Flame Ignition Failure Typical Ignition Type Source Response Hardware of Gas Time
Norton 201, Norton Switched Line 271, Hot Surface 1.5 sec. Nat or LP Voltage Elements, Q354 Flame Rod
Intermittent Pilot
1 or 2 Rods S8610U3009
Intermittent C Pilot
C1 or 2 Rods
15 sec. or 90 sec. C Field Selectable
5 Minute Delay After C Failed Trial for Ignition
15 0 sec. sec.oror3090sec. sec. Field FieldSelectable Selectable
5 Minute Delay After 2.0 sec. max. Failed Trial for Ignition
0 sec. or 30 sec. Nat or LP Field Selectable
2.0 sec. max. Internal Q345, Q3451,Nat Q3452 or LP
Y8610U6006
Intermittent Pilot
Single Rod Y8610U6006
Intermittent C Pilot
CSingle Rod
15 sec. or 90 sec. C Field Selectable
5 Minute Delay After C Failed Trial for Ignition
15 sec. or 90 sec. 0 sec. Field Selectable
5 Minute Delay After 2.0 sec. max. Failed Trial for Ignition
sec. Nat or0LP
Adapter for 2.0 sec. max. Pilot Burner Internal Nat or LP Included
Notes:
Ignition Includes Source
Typical Ignition Honeywell Hardware
Includes
S89C1004, S89C1007, S89C1012, S89C1046, S89C1087, Norton S89C1103, 201, Norton S89D1002, S89G1005, Switched Line S89G1011, 271, S89G1013, Hot Surface S89G1021, S89G1029, Voltage S89G1047, S89H1003, Elements, S89H1011, S89H1029, S89J1008, Q354 Flame S890D1006, Rod S890G1003, S890G1037, S890H1002, S890H1010
Integral S86 Series ,S90 Series, S8600Integral Series, Damper Internal S8610Q345, Series, Q3451, S8620Q3452 Series, S8660 Damper Series, Connector S8670 Series, S8680J1004 Connector
Internal
Adapter for Pilot Y8610U3003 Burner Included
CROSS-REFERENCE
CROSS-REFERENCE
White-Rodgers Honeywell
Johnson RobertshawWhite-Rodgers Controls
HS780-17NL, 104A, 306A, S89C1004, S89C1007, S89C1012, S89C1046, 308A, HS780-17NR 104A, S89C1087, 50E47 1-79, S89C1103, 101-179, S89D1002, S89G1005, 50E47 1-79, 101-179, 306A, 308A, HS780-34NL S89G1011, 201-279,S89G1013, 301-379, 5047F S89G1021, S89G1029, 201-279, 301-379, 5047F 108A, 304A, 306A, 308A, S89G1047, 1-79, 101-179, S89H1003, 201-279, S89H1011, S89H1029, 1-79, 101-179, 201-279, 312A, HS780-34NR 104A, S89J1008, 301-379 S890D1006, S890G1003, 301-379 306A, 308A, 312A, S890G1037, S890H1002, S890H1010 HS780-34PL 308A
Johnson Controls
Robertshaw
HS780-17NL, 104A, 306A, 308A, HS780-17NR 104A, 306A, 308A, HS780-34NL 108A, 304A, 306A, 308A, 312A, HS780-34NR 104A, 306A, 308A, 312A, HS780-34PL 308A
710-713, 715, 735-737, 710-713, 715, 735-737, 780-002, 780-003, CSA42, 43, 780-002, 780-003, 50D49-350, S86 Series ,S90 50D49-360, Series, S8600 Series, 780-701, 780-715, 50D49-350, 50D49-360, 44, 45, 46, 48, 780-701, 780-715, S8610 50D49-361, Series, 50D50-843, S8620 Series, S8660780-735, Series, 780-736, 50D49-361, 50D50-843, 49, G60, G65, 780-735, 780-736, S8670 50D-401 Series, S8680J1004 780-737, 780-845, 50D-401 G67, G770 780-737, 780-845, SP710, SP715, SP720, Series SP710, SP715, SP720, SP730, SP735, SP750 Series SP730, SP735, SP750 Series
16 CSA42, 43, 44, 45, 46, 48, 49, G60, G65, G67, G770 Series
Y8610U3003
technical information
S8610U3009
FEATURES AND FUNCTIONS
Notes:
1. Ignition Sequence
1. Ignition Sequence
C
Continous retry — After trial for ignition, pilot gas shutsContinous off for retry — After trial for ignition, pilot gas shuts off for C 5 minutes, then another trial for pilot ignition takes place.5 minutes, then another trial for pilot ignition takes place.
P
The number of trials for ignition and trial time is determined The number by of trials for ignition and trial time is determined by the selection tab. If a selection tab is not Pinstalled, the module the selection tab. If a selection tab is not installed, the module will operate at four seconds trial time and one ignition trial. will operate at four seconds trial time and one ignition trial.
cross reference
For a complete cross-reference, visit www.customer.honeywell.com
288 16_Troubleshooting_p295.indd 288-289
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
289 3/24/08 4:30:35 PM
SECTION
SECTION
16
16
Technical Information
Technical Information
Universal Electronics Fan Timer OEM Replacement Guide RECOMMENDED DIP SWITCH SETTINGRECOMMENDED DIP SWITCH SETTING Model
Original OEM BrandsModel
1 Original OEM Brands
2
1
3
2
4
3
Model
4
Original OEM BrandsModel
1 Original OEM Brands
2
1
3
2
4
3
4
Rheem, RuudST9101A1006
Off
Rheem, Ruud
On
Off
Off
On
On
Off
ST9120C4016
On
ICP, Heil, Tempstor, Arcoaire, ST9120C4016 Comfortmaker, Keep Rite
On
ICP, Heil, Tempstor, Arcoaire, Off Comfortmaker, Keep Rite
On
On
Off
On
On
On
ST9101A1014
Rheem, RuudST9101A1014
Off
Rheem, Ruud
On
Off
Off
On
On
Off
ST9120C4040
On
ICP, Heil, Tempstor, Arcoaire, ST9120C4040 Comfortmaker, Keep Rite
On
ICP, Heil, Tempstor, Arcoaire, Off Comfortmaker, Keep Rite
On
On
Off
On
On
On
ST9101A1022
Trade ST9101A1022
Off
Trade
On
Off
Off
On
On
Off
ST9120C4057
On
ICP, Heil, Tempstor, Arcoaire, ST9120C4057 Comfortmaker, Keep Rite
On
ICP, Heil, Tempstor, Arcoaire, Off Comfortmaker, Keep Rite
On
On
Off
On
On
On
ST9120A1006
Armstrong Air ST9120A1006 Concord, Aire Ease
Off
Armstrong Air Concord, Aire Ease
On
Off
Off
On
On
Off
*ST9120C5005
On
ICP, Heil, Tempstor, Arcoaire, *ST9120C5005 Comfortmaker, Keep Rite
Off
ICP, Heil, Tempstor, Arcoaire, Off Comfortmaker, Keep Rite
Off
On
Off
On
On
On
ST9120A2004
Armstrong Air ST9120A2004 Concord, Aire Ease
Off
Armstrong Air Concord, Aire Ease
Off
Off
On
Off
Off
On
*ST9120C5013
Off
ICP, Heil, Tempstor, Arcoaire, *ST9120C5013 Comfortmaker, Keep Rite
Off
ICP, Heil, Tempstor, Arcoaire, Off Comfortmaker, Keep Rite
Off
On
Off
On
On
On
ST9120B1005
Ducane ST9120B1005
Off
Ducane
Off
Off
Off
Off
On
Off
*ST9120D3009
On
*ST9120D3009 Goodman, GMC, Janitrol
Off Goodman, GMC, Janitrol
Off
Off
On
Off
On
On
On
ST9120C1012
ST9120C1012 Snyder General
Off
Snyder General
On
Off
Off
On
Off
Off
ST9120G2008
Off
ICP, Heil, Tempstor, Arcoaire, ST9120G2008 Comfortmaker, Keep Rite
On
ICP, Heil, Tempstor, Arcoaire, On Comfortmaker, Keep Rite
On
On
On
Off
On
Off
ST9120C1020
Nordyne ST9120C1020
Off
Nordyne
On
Off
Off
On
Off
Off
ST9120G2016
Off
ICP, Heil, Tempstor, Arcoaire, ST9120G2016 Comfortmaker, Keep Rite
On
ICP, Heil, Tempstor, Arcoaire, On Comfortmaker, Keep Rite
On
Off
On
On
Off
On
ST9120C2002
Off
York
On
Off
Off
On
On
Off
ST9120G2024
On
Skymark ST9120G2024
On
Skymark
Off
On
Off
Off
On
Off
On
ST9120C2010
Ducane ST9120C2010
Off
Ducane
On
Off
Off
On
On
Off
ST9120G2032
On
Skymark ST9120G2032
Off
Skymark
Off
Off
Off
Off
On
Off
On
ST9120C2028
Armstrong Air ST9120C2028 Concord, Aire Ease
Off
Armstrong Air Concord, Aire Ease
On
Off
Off
On
On
Off
ST9120G4004
On
ICP, Heil, Tempstor, Arcoaire, ST9120G4004 Comfortmaker, Keep Rite
On
ICP, Heil, Tempstor, Arcoaire, Off Comfortmaker, Keep Rite
On
On
Off
On
On
On
ST9120C3000
ICP, Heil, Tempstor, Arcoaire, ST9120C3000 Comfortmaker, Keep Rite
On
ICP, Heil, Tempstor, Arcoaire, Off Comfortmaker, Keep Rite
On
On
Off
On
On
ST9120G4012
On
ICP, Heil, Tempstor, Arcoaire, ST9120G4012 Comfortmaker, Keep Rite
On
ICP, Heil, Tempstor, Arcoaire, Off Comfortmaker, Keep Rite
On
On
Off
On
On
On
ST9120C3018
Off
On
Off
Off
On
Off
Off
ST9120G4038
Off
Trade
ST9120G4038
On
Trade
Off
On
On
Off
On
On
On
ICP, Heil, Tempstor, Arcoaire, ST9120C4008 Comfortmaker, Keep Rite
On
ICP, Heil, Tempstor, Arcoaire, Off Comfortmaker, Keep Rite
On
On
Off
On
On
ST9120U1003
On
Trade
ST9120U1003
Off
Trade
Off
Off
On
Off
On
On
On
ST9120C2002
ST9120C3018
ST9120C4008
Bard
Bard
cross reference
*ST9120U Factory Default Setting
York
16 technical information
ST9101A1006
*ST9120U Factory Default Setting
For a complete cross-reference, visit www.customer.honeywell.com
290 16_Troubleshooting_p295.indd 290-291
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
291 3/24/08 4:30:36 PM
Technical Information
SECTION
SECTION
16
16
Technical Information
Oil Primaries Selection Guide OIL PRIMARIES
OIL PRIMARIES Specifications
Ignition Type
Universal ServiceIgnition Part Type
R7184U1004
R7184U1004
Interrupted
Cross-Reference
Direct Service Part LockoutDirect Service Part Lockout Manual Trip Lever w/ LED Valve On Delay (sec.) Blower Off Delay Valve(min.) On Delay (sec.) Alarm Blower Off Delay (min.) Universal Service Part Contacts Alarm Contacts Replacement Time (sec.)Replacement Time (sec.) Indicator
R7184U1004
Interrupted
Specifications
R7184U1004
0/15
15
0/2/4/6
0/15
Yes
0/2/4/6
15
R7184A1026
R7184A1026
R7184B1024
R7184B1024
Yes Yes
15
15
R7184P1098
R7184P1098
15
0.25
15
R7184U1012
R7184U1012
0/15
0/2/4/6
0/15
0.25 Yes
0/2/4/6
50200-02S, 602000-02S, 6020002S015120, R7184P1031, 6020002S030015, R7184P1049, 6020002S030015, R7184P1056, 6020002S030030, R7184P1064, 6020002S030120, 6020002S030300, R7184P1072 6020002S030010
R7184A1075, R7184A1000
R7184A1075, 40200-02S R7184A1000
R7184B1032, R7184B1016
R7184B1032, R7184B1016
R7184P1080
R7184P1080
R7184U1020
R7184U1020 R7184U1020 R7184A1042
45
R7184U1004
R8184G4066R7184U1004
15
R8184G4066
15
Yes
R8184G1294, R8184G1302, Yes R8184G4074, R8184G4033
R7184U1012
R8184G4074R7184U1012
30
R8184G4074
30
Yes
R7184A1042
0/15
45
No 0/2/4/6
0/15
Intermittent R7184U1020
R8184M1051
Yes
Yes R8184G4009R7184U1020
R8184M1051 R8184M1051
45
R8184G4009
45
R8184M1051
0/2/4/6
White-Rodgers
50200-02S, 602000-02S, 6020002S015120, 6020002S030015, 6020002S030015, 6020002S030030, 6020002S030120, 6020002S030300, 6020002S030010
669-640,669-670 40200-02S
669-640,669-670
16
No
Yes
No R7184A1018
669-440, 669-445, 42230-02S 669-470, 669-540
669-440, 669-445, 669-470, 669-540
R8184G1294, R8184G1302, R8184G4074, R8184G4033
668-601, 668-670
668-601, 668-670
R8184G1393, R8184G1302, Yes R8184G4074, R8184G4033
R8184G1393, R8184G1302, R8184G4074, R8184G4033
668-501
668-501
R8184G1286, R8184G1427, R184G4025, R8184G4082, R8184G1458Yes
R8184G1286, R8184G1427, R184G4025, 48245-S R8184G4082, 668-401, 668-0415, 668-430, 48245-S668-515 R8184G1458
Yes
Yes
Yes
Yes
Yes
Yes (no LED)Yes
42230-02S R7184A1018
No
668-401, 668-0415, 668-430, 668-515
668-430
668-430
668-441, 668-451, 668-454
668-441, 668-451, 668-454
Yes (no LED) R8184M1002
R8184M1002
(1) Includes 40 VA transformers and heat/cool thermostat connections (1) Includes 40 for VA warm-air transformers furnaceand applications. heat/cool thermostat connections for warm-air furnace applications.
cross reference
For a complete cross-reference, visit www.customer.honeywell.com
292 16_Troubleshooting_p295.indd 292-293
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
technical information
30
R7184U1020
White-Rodgers Carlin
Yes
R7184U1012 R7184A1034
R7184A1034
Carlin Honeywell
R7184P1031, R7184P1049, R7184P1056, R7184P1064, R7184P1072 Yes
R7184U1012
Intermittent
30
Manual Trip Lever w/ LED Honeywell Indicator
Cross-Reference
293 3/24/08 4:30:36 PM
Technical Information
SECTION
SECTION
16
16
Technical Information
Multi-Function Aquastat® Selection Guide FUEL
Product Number
Gas
LOW FUEL LIMIT
Operating Range, Product Oil Number Gas Low Limit (˚F)
LOW LIMIT HIGH LIMIT
Differential Differential Temperature, Operating Range, OperatingDifferential Range, Temperature, Operating Range,Factory Oil Temperature, Low Limit (˚F) Low Limit (˚F) High Limit (˚F) Low Limit (˚F) High Limit (˚F) Stop (˚F) High Limit (˚F)
•
•L6081A1010
110 to 220
•
•
L6081A1036
•
•L6081A1036
110 to 220
•
•
L8148E1265
•
L8148E1265
L8124E1016
•
L8124E1016
L8148J1009
•
L8148J1009
10-25
110 to 220
130 to 240
110 to 220
130 to 240
•
10-25
180 to 240
•
10 to 25
110 to 220
•
130 to 240
10 to 25
120 to 240
FEATURES AND FUNCTIONS
Differential Switching Action Temperature, High Limit (˚F)
Factory Anticipator Stop (˚F)
Setting
Anticipator Notes Setting
CROSS-REFERENCE
Mounting
OEM Part Notes Number
OEM Part Number
130 to 240
10 fixed
SPDT
SPDTH
H
L6081A1069
L6081A1069
10 fixed
130 to 240
10 fixed
SPDT
SPDTH
H
L4081A1023, L4081A1148, L4081A1155, L4081A1171, L4081A1189, L4081A1197
L4081A1023, L4081A1148, L4081A1155, L4081A1171, L4081A1189, L4081A1197
15 fixed
180 to 240
152 SPST: fixed High Limit & Circulator
0.2 A 2 SPST: High LimitV& Circulator
0.2 A
V
L8148E1158, L8148E1182, L8148E1216, L8148E1065
L8148E1158, L8148E1182, L8148E1216, L8148E1065
10 fixed
130 to 240
2 SPST: High & Low Limit 10 fixed
0.2 A
0.2 A
8 fixed
120 to 240
SPST: High Limit & Circulator240 82fixed
0.2 A 2 SPST: High Limit V/H& Circulator
Universal Oil, Digital Display and Settings, All L8124A or C, L8148A or C, L7224A or C, Used with Oil Burner Applications, L7248A or C, L8151A EnviraCOM® Communications
All L8124A or C, L8148A or C, L7224A or C, L7248A or C, L8151A
240
3 SPST: High and Low Limit, 5 to 20 adj. Circulator
•L7224U1002
110 to 220
•
10 to 25
110 to 220
130 to 240
10 to 25
5 to 20 adj.
130 to 240
L8124A1007
•L8124A1007
110 to 220
•
10 to 25
110 to 220
130 to 240
10 to 25
10 fixed
130 to 240
10 fixed
0.2 A
L8124C1003
•L8124C1003
110 to 220
•
10 to 25
110 to 220
130 to 240
10 to 25
10 fixed
130 to 240
2 SPST: High & Low Limit 10 fixed
0.2 A
L8124G1020
•L8124G1020
110 to 220
•
10 to 25
110 to 220
130 to 240
10 to 25
10 fixed
130 to 240
2 SPST: High & Low Limit 10 fixed
L8124L1011
•L8124L1011
110 to 220
•
10 to 25
110 to 220
130 to 240
10 to 25
10 fixed
130 to 240
L8148A1017
•L8148A1017
8 fixed
140 to 240
140 to 240
Switching Mounting Action
CROSS-REFERENCE
10 fixed
L7224U1002
•
FEATURES AND FUNCTIONS
240
0.1 A
2 SPST: High & Low Limit
0.2 A
V/H
Universal Oil, Digital Display and Settings, 3 SPST: High and Low Limit, V/H/F Used with Oil0.1 Burner A Applications, V/H/F Circulator EnviraCOM® Communications
V
16
L8124A1015, L8124A1015, L8124A1049, L8124A1106, L8124A1015, L8124A1015, L8124A1049, L8124A1106, L8124A1114, L8124A1130, L8124A1155, L8124A1015 L8124A1114, L8124A1130, L8124A1155, L8124A1015
0.2 A
V
2 SPST: High &HLow Limit
0.2 A
H
L8124C1094, L8124C1102
L8124C1094, L8124C1102
0.2 A
2 SPST: High &VLow Limit
0.2 A
V
L8124G1004, L8124G1012
L8124G1004, L8124G1012
2 SPST: High & Low Limit 10 fixed
0.2 A
2 SPST: High &HLow Limit
0.2 A
H
L8124L1003, L8124L1029, L8124G1038, L8124G1046
L8124L1003, L8124L1029, L8124G1038, L8124G1046
SPST: High Limit & Circulator240 82fixed
0.2 A 2 SPST: High LimitH& Circulator
0.2 A
H
L8148A1165, L8148A1157, L8148A1124, L8148A1090, L8148A1082, L8148A1009
L8148A1165, L8148A1157, L8148A1124, L8148A1090, L8148A1082, L8148A1009
cross reference
For a complete cross-reference, visit www.customer.honeywell.com
294 16_Troubleshooting_p295.indd 294-295
F.W. Webb Company
www.fwwebb.com
The F.W. Webb Heating Catalog
F.W. Webb Company
technical information
L6081A1010
110 to 220
HIGH LIMIT
295 3/24/08 4:30:37 PM
SECTION
A
Index
F.W. Webb is the exclusive distributor of PurePro® products. When it comes to oil heat related maintenance and replacement parts and equipment, PurePro products are the contractor’s choice. From oil filters to environmentally safe chemicals, soot saws to hand cleaners PurePro has the products you need at the price you deserve.
PurePro® LWC Blow Down Valve . . . . . . . . . . . . . . . . . . . . . . 54 Boiler Trim Packages . . . . . . . . . . . . . . . . . . . . . . . 41 Boiler & Heating System Stop Leaks . . . . . . . . . . . 14 Boiler System Treatments . . . . . . . . . . . . . . . . . . . 14 Cadium Sulfide Flame Detector . . . . . . . . . . . . . . . 27 CO2 Blowout Gun . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Degreasers—Super Degreaser . . . . . . . . . . . . . . . . 12 Degreasers—Super Foam Cleaner . . . . . . . . . . . . . 12 Degreasers—Grease Gone . . . . . . . . . . . . . . . . . . . 12 Digital Non-Programmable Thermostats D110 Heating Thermostat . . . . . . . . . . . . . . . . 178 D210 Heating Thermostat . . . . . . . . . . . . . . . . 178 D111 Heating & Cooling Thermostat . . . . . . . . 178 Flanged Ball Valve . . . . . . . . . . . . . . . . . . . . . . . . . 63 Fuel Oil Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Fuel Oil Filter—Refill Cartridges . . . . . . . . . . . . . . 143 Fuel Oil Filters—77FW . . . . . . . . . . . . . . . . . . . . . 142 Fuel Oil Filters—99FW . . . . . . . . . . . . . . . . . . . . . 142 Furnace Cement . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Gas Boiler Heat Manager . . . . . . . . . . . . . . . . . . . . 37 Hand Cleaner—Wipes . . . . . . . . . . . . . . . . . . . . . . . 11 Hand Cleaner—Heavy Duty Waterless Soft Gel . . . 11 Vacuum/Pressure Handpump . . . . . . . . . . . . . . . 144 Heavy Duty Deodorant Gel Cup . . . . . . . . . . . . . . . 15 MLV2 Line Voltage Heating Thermostat . . . . . . . . . 176
PurePro® Odor Out Spray . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Odor Absorbant Powder . . . . . . . . . . . . . . . . . . . . . 14 Oil Burner Couplings—Nylo-Flex . . . . . . . . . . . . . . 146 Oil Tank Patch . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Programmable Heating & Cooling Thermostats DP711 7 Day Thermostat . . . . . . . . . . . . . . . . 182 DP711TS 7 Day Thermostat Touch Screen . . 183 DP722 7 Day Thermostat w/Universal Compatibility . . . . . . . . . . . . . . 183 Programmable 5-2 Thermostat DP511 5 Day . . . . . . . . . . . . . . . . . . . . . . . . . . 182 DPH521 Heat Pump . . . . . . . . . . . . . . . . . . . . 184 Pump Testers T10W . . . . . . . . . . . . . . . . . . . . . . . 173 Spin-on Oil Filters . . . . . . . . . . . . . . . . . . . . . . . . . 142 Suction Line Analyzer T15W . . . . . . . . . . . . . . . . 173 Water Finding Paste . . . . . . . . . . . . . . . . . . . . . . . . 15 Water Finding Paste . . . . . . . . . . . . . . . . . . . . . . . . 153 WP-3 Advanced Heating Oil Additive . . . . . . . . . . . 15 V-Belts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
PurePro products are exclusively designed for the professional.
The F.W. Webb Heating Catalog
F.W. Webb Company
i
SECTION
A
Index 2 in 1 Safety Oil Tank System . . . . . . . . . . . . . . . . 152 8-Way Boiler Water Treatment . . . . . . . . . . . . . . . . . 15 A AC Ammeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 Acid-Away . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Accu-Flo Balancing Valve . . . . . . . . . . . . . . . . . . . . . 68 Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Air Bear Right Angle Air Cleaner . . . . . . . . . . . . . . . . 2 Air Bear Supreme Air Cleaner . . . . . . . . . . . . . . . . . . 2 Air Boosters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 Air Cleaners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,2,3 Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Media Replacement Air Filter . . . . . . . . . . . . . 9 Air Purgers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Air Scoops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Air Seperators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Air Tube Combinations . . . . . . . . . . . . . . . . . . . . . . 135 Air Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Air Vents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43,44 Spirovent Air Eliminator . . . . . . . . . . . . . . . . 43 Spirotop Air Release Valve . . . . . . . . . . . . . . 43 PV Series Supervent Air Eliminator . . . . . . . 43 DuoVent . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Automatic Air Vents . . . . . . . . . . . . . . . . . . . 44 Float Type Air Vents . . . . . . . . . . . . . . . . . . . 45 Allanson Transformers . . . . . . . . . . . . . . . . . . . . . . 140 Allgator Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 Aluminum Chimney Liner Kits . . . . . . . . . . . . . . . . 224 Aluminum Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Amp-Master Thermostat Circuit Meter . . . . . . . . . . 171 Antifreeze . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Aquasorb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Aquastat Combination/High Limit Controller . . . . . . . . 28 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Electronic Triple . . . . . . . . . . . . . . . . . . . . . . 30 Electronic Universal . . . . . . . . . . . . . . . . . . . 30 Hydrostat . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Multi-Function . . . . . . . . . . . . . . . . . . . . . 30, 31 Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Single . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Water Boiler . . . . . . . . . . . . . . . . . . . . . . . . . 29 Water Heater . . . . . . . . . . . . . . . . . . . . . 28, 29 Wells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 B B-Belts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 B-Vent Connector . . . . . . . . . . . . . . . . . . . . . . . . . . 224 B-Vent Gas Connector . . . . . . . . . . . . . . . . . . . . . . 224 Bacharach Testers . . . . . . . . . . . . . . . . . . . . . . . . . 172
ii
F.W. Webb Company
Backflow Preventor . . . . . . . . . . . . . . . . . . . . . . . . . 43 Backflow Preventor/Fill Valve . . . . . . . . . . . . . . . . . . 43 Balancing Valves . . . . . . . . . . . . . . . . . . . . . 67, 68, 72 Ball Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66, 67 Baseboard . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 74, 75 Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Battery Chargers . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Battery Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Bauer Ladders . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 Bearing Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . 60 Beckett Oil Burner Parts & Accessories . . . . . . . . . 131 Black Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 Black Malleable Fittings . . . . . . . . . . . . . . . . . 159, 160 Black Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 Blow Down Valves . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Blower Bearings . . . . . . . . . . . . . . . . . . . . . . . . . 86, 87 Blower Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Belted Fan . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Direct Drive Fan . . . . . . . . . . . . . . . . . . . . . . 84 Blower Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Sleeve Bearings . . . . . . . . . . . . . . . . . . . 86, 87 Thrust Collar/Spacer Kits . . . . . . . . . . . . . . . 86 Vibro Pads . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Motor Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Pulleys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Motor Adjustment Grommets . . . . . . . . . . . . 87 Ball Bearings . . . . . . . . . . . . . . . . . . . . . . . . 87 Shafts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Wheels . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 Boiler Brushes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Boiler Pressure Testing Gauge . . . . . . . . . . . . . . . . 173 Boiler Headers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Boiler Relief Valves . . . . . . . . . . . . . . . . . . . . . . 46, 47 Adjustable . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Commercial . . . . . . . . . . . . . . . . . . . . . . . . . 47 Hot Water . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Poppet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Steam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 T & P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Boiler Reset Controls . . . . . . . . . . . . . . . . . . . . . 38, 39 One Stage Setpoint Control . . . . . . . . . . . . . 38 Boiler/DHW Controls . . . . . . . . . . . . . . . . . . 38 Stand Alone Heating Controls . . . . . . . . . . . 39 Pump Sequencer . . . . . . . . . . . . . . . . . . . . . 40 Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Room Temperatire Units . . . . . . . . . . . . . . . . 40 Boiler Stop Leak . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
www.fwwebb.com
SECTION
A Boiler System Cleaner . . . . . . . . . . . . . . . . . . . . . . . 14 Boiler Treatment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Boiler Trim Packages . . . . . . . . . . . . . . . . . . . . . . . . 41 Boiler Water Chemicals . . . . . . . . . . . . . . . . . . . 14, 15 Brass Flare Fittings . . . . . . . . . . . . . . . . . . . . 157, 158 Brazing Rods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 Brushes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Burner Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . 146 Burner Head Protector . . . . . . . . . . . . . . . . . . . . . . 148 Burner Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 PSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Burner Tune Up Kits . . . . . . . . . . . . . . . . . . . . . . . . 139 Buss Bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 C Cad Cell Eyes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Cad Cell Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Carbon Monoxide Detector . . . . . . . . . . . . . . . . . . 167 Accessories . . . . . . . . . . . . . . . . . . . . . . . . 167 Carlin Ignitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Carlin Oil Burner Parts & Accessories . . . . . . . . . . 137 Ceiling Diffusers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Channel Lock Hand Tools . . . . . . . . . . . . . . . . . . . 203 Charter Plastic Gas Pipe . . . . . . . . . . . . . . . . . . . . 126 Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Chimney Ameri-Caps . . . . . . . . . . . . . . . . . . . . . . . . . 228 Chimney Kits . . . . . . . . . . . . . . . . . . . . . . . 230 Liner—Aluminum . . . . . . . . . . . . . . . . . . . . 224 Liner—For Oil . . . . . . . . . . . . . . . . . . . . . . . 225 Temperature Engineered Chimney . . . . . . . 228 Chimney Sections / Pipe . . . . . . . . . . . . 228 Adapters / Accessories . . . . . . . . . 229, 230 Type B Gas Vent Round Pipes / Adapters / Accessories . . . 226–228 Type B Gas Vent Oval Adapters . . . . . . . . . 228 Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Circuit Setter Balance Valves . . . . . . . . . . . . . . . . . . 72 Circulator Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Couplings . . . . . . . . . . . . . . . . . . . . . . . . 62, 85 Flanges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . 60, 62 Impellers . . . . . . . . . . . . . . . . . . . . . . . . . 59, 60 Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Seal Kits . . . . . . . . . . . . . . . . . . . . . . . . . 60, 62 Switching Relays . . . . . . . . . . . . . . . . . . . . . 34 Circulators Bell & Gossett . . . . . . . . . . . . . . . . . . . . . . . . 59 Oil Lubricated . . . . . . . . . . . . . . . . . . . . . 59 Maintenance-Free . . . . . . . . . . . . . . . . . . 59 The F.W. Webb Heating Catalog
Index Circulators (continued) Replacement Parts . . . . . . . . . . . . . . 59, 60 Grundfos . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Taco . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61, 62 “00” Series Cartridge Circulators . . . . . . . 61 Red Baron Circulators . . . . . . . . . . . . . . . 62 Replacement Parts . . . . . . . . . . . . . . . . . 62 Co2 Blowout Gun . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Coin Vents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Colco Cement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Combination Controls . . . . . . . . . . . . . . . . . . . . . . . . 31 Combustion Air System . . . . . . . . . . . . . . . . . 214, 215 ComboVent . . . . . . . . . . . . . . . . . . . . . . . . . 212 Combustion Chambers . . . . . . . . . . . . . . . . . . 147, 148 Replacement Kits . . . . . . . . . . . . . . . . . . . . 149 Combustion Testers . . . . . . . . . . . . . . . . . . . . . . . . 172 Compression Pipe Couplings . . . . . . . . . . . . . . . . . 154 Contact Probes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168 Immersion Probe . . . . . . . . . . . . . . . . . . . . 168 Thermocouple Module . . . . . . . . . . . . . . . . 168 Pipe Clamp Temperature Probe . . . . . . . . . 168 Copper Fitting Brush . . . . . . . . . . . . . . . . . . . . . . . 193 Copper Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 Coated Soft Copper Tubing for Fuel Oil . . . 156 Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 CounterStrike Track Pipe . . . . . . . . . . . . . . . . . . . . 113 Craftsman Hand Tools . . . . . . . . . . . . . . . . . . 198–200 Crown Crimper . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 Cycle Pilot Retrofit Kit . . . . . . . . . . . . . . . . . . . . . . . 100 D Damper Bottom Mount . . . . . . . . . . . . . . . . . . . . . . . . 22 Round, Spring Return . . . . . . . . . . . . . . . . . . 22 Dayco Bulk Hose . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Degreaser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Dehumidifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Delavan Nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Deodorant Gel Cup . . . . . . . . . . . . . . . . . . . . . . . . . 15 Designline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Diffusers Baseboard . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Boot and Damper All in One . . . . . . . . . . . . . 21 Ceiling . . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 21 Sidewall . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Dormont Connectors . . . . . . . . . . . . . . . . . . . 118–120 Draft Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 Draft Inducer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 Drill Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
F.W. Webb Company
iii
SECTION
A
Index E Ear Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 ECOGARD Oil Tanks . . . . . . . . . . . . . . . . . . . . . . . 151 Econ-O-Gage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Electrical Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 BX/Conduit/Fuses . . . . . . . . . . . . . . . . . . . . . 16 Current Tap . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Duct Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Extention Cords . . . . . . . . . . . . . . . . . . . . . . 18 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Ground Rod/Clamp . . . . . . . . . . . . . . . . . . . . 18 Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Light Bulbs . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Meters . . . . . . . . . . . . . . . . . . . . . 164, 165, 169 Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Recepticles . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Roto Splitter . . . . . . . . . . . . . . . . . . . . . . . . . 18 Staples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Test Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Testers . . . . . . . . . . . . . . . . . . . . . 18, 166, 170 Wire Nuts . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Wire-THNN-Romex . . . . . . . . . . . . . . . . . . . 16 Electric Tools . . . . . . . . . . . . . . . . . . . . . . . . . 204, 205 Cordless Combination Kit . . . . . . . . . . . . . . . . . . . . . 204 Cordless Sawzall . . . . . . . . . . . . . . . . . . . . 204 Cordless Drill . . . . . . . . . . . . . . . . . . . . . . . 204 Circular Saw . . . . . . . . . . . . . . . . . . . . . . . . 204 Impact Wrench . . . . . . . . . . . . . . . . . . . . . . 204 Caulking Gun . . . . . . . . . . . . . . . . . . . . . . . 204 Carring Case . . . . . . . . . . . . . . . . . . . . . . . 205 Corded Reversible Drill . . . . . . . . . . . . . . . . . . . . . . 204 Right Angle Drill . . . . . . . . . . . . . . . . . . . . . 204 Abrasive Cut-Off Saw . . . . . . . . . . . . . . . . . 204 Deep Cut Portable Band Saw . . . . . . . . . . . 204 Sawzall . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 Metal Cutting Shears . . . . . . . . . . . . . . . . . 204 Rotary Hammer . . . . . . . . . . . . . . . . . . . . . 204 Super Hawg . . . . . . . . . . . . . . . . . . . . . . . . 204 Caulking Gun . . . . . . . . . . . . . . . . . . . . . . . 204 Job Site Radio . . . . . . . . . . . . . . . . . . . . . . 205 Reversible Drive . . . . . . . . . . . . . . . . . . . . . 205 Electrode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Electrode Kits . . . . . . . . . . . . . . . . . . . . . . . 138 Porcelains . . . . . . . . . . . . . . . . . . . . . . . . . . 139
iv
F.W. Webb Company
Electrode (continued) Porcelain Squeeze & Snap Cutter . . . . . . . 139 Setting Gague . . . . . . . . . . . . . . . . . . . . . . . 139 Tip Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Tune Up Kits . . . . . . . . . . . . . . . . . . . . . . . . 139 Electronic Transformers . . . . . . . . . . . . . . . . . . . . . 140 Electrostatic Air Filters . . . . . . . . . . . . . . . . . . . . . . . . 9 Emergency Switch Plates . . . . . . . . . . . . . . . . . . . . . 17 EMT Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 ESP Zone Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Evaluation Forms (Heating System) . . . . . . . . . . . . 173 EWC Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . 22–24 Expansion Tanks (Flexcon) . . . . . . . . . . . . . . . . . . . 41 F Fan & Limit Control, Snap Disk . . . . . . . . . . . . . . . . 33 Fan & Limit Controls . . . . . . . . . . . . . . . . . . . . . . . . 32 Warm Air Controls . . . . . . . . . . . . . . . . . . . . 33 Flush Mount Fan . . . . . . . . . . . . . . . . . . . . . . 33 Fan Center Relays . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Fan Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34, 35 Fan Timers (Electronic) . . . . . . . . . . . . . . . . . . . . . . 32 Field Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . 4, 211 Firebrick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Firomatic Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 First Aid Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Flanged Ball Valve . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Flame Detector (Cadium Sulfide) . . . . . . . . . . . . . . . 27 Flame Mirrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 Flame Stop (Flare Shield) . . . . . . . . . . . . . . . . . . . 192 Flare Fittings (Brass) . . . . . . . . . . . . . . . . . . . 157, 158 Flashlights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Flo-Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Flo-Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Flow Control Valve . . . . . . . . . . . . . . . . . . . . . . . 66, 72 Flow Regtulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Flow Switches . . . . . . . . . . . . . . . . . . . . . . . . . . 57, 58 Fluke Meter Accessories . . . . . . . . . . . . . . . . . . . . 165 Forced Air Zone Controls . . . . . . . . . . . . . . . . . . . . . 22 FPPF Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Freeze Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Fuel Pump Bleeders . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 By Pass Plugs . . . . . . . . . . . . . . . . . . . . . . 145 Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Strainers . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Beckett . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Danfoss . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 J&H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
www.fwwebb.com
SECTION
A Fuel Pump (continued) Mini . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Suntec . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Furnace Cement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Furnace Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Furnace Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . 148 Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 G Garden Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Gas Appliance Connectors . . . . . . . . . . . . . . . 118–120 Gas Appliance Restraining Device . . . . . . . . . . . . . 120 Gas Ball Valves . . . . . . . . . . . . . . . . . . . . . . . 127, 128 Gas Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Gas Cans / Accessories (Metal) . . . . . . . . . . . . . . . 153 Gas Cocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 Gas Connectors . . . . . . . . . . . . . . . . . . . 118, 119, 120 Fittings . . . . . . . . . . . . . . . . . . . . . . . . 119, 120 Coiled Restraining Device . . . . . . . . . . . . . 120 Gas Ignition Controls, Robertshaw . . . . . . . . 90, 91, 92 Replacement Sensors . . . . . . . . . . . . . . . . 109 Gas Ignition Module . . . . . . . . . . . . . . . . . . . . . . . . . 94 Gas Ignition Module Tester . . . . . . . . . . . . . . . . . . . . 90 Gas Pilot Burners . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Honeywell . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Johnson Controls . . . . . . . . . . . . . . . . . . . . 108 Gas Pilot Kit (Universal) . . . . . . . . . . . . . . . . . . . . . 109 Gas Pilot Ignition Control . . . . . . . . . . . . . . . . . . . . . 92 Honeywell . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Johnson Controls . . . . . . . . . . . . . . . . . . . . . 92 Gas Pilot Module . . . . . . . . . . . . . . . . . . . . . . . . 93, 94 Gas Pilot Orifice Reamers . . . . . . . . . . . . . . . . . . . 106 Gas Pilot Orifices . . . . . . . . . . . . . . . . . . . . . . 106, 107 Gas Pilot Orifices Kits . . . . . . . . . . . . . . . . . . . . . . . 106 Gas Pilot Relight Control . . . . . . . . . . . . . . . . . . . . . 91 Gas Pilot Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Gas Pipe Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 TracPlpe . . . . . . . . . . . . . . . . . . . . . . . 114–116 Bulk Hose / Accessories . . . . . . . . . . . . . . . 117 Gas Pressure Regulator Kits Gas Regulators Gas Shutoff Valves Gas Spark Ignitor . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Gas Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Gas Valves . . . . . . . . . . . . . . . . . . . . . . . . 95–99, 103 Oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Water Heater . . . . . . . . . . . . . . . . . . . . . . . . 95 Robertshaw . . . . . . . . . . . . . . . . . . . . . . 95–99 White-Rodgers . . . . . . . . . . . . . . . . . . . 95, 100
The F.W. Webb Heating Catalog
Index Gas Valves (continued) Honeywell . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Gas Valves, Electronic Single Stage: Standing Pilot . . . . . . . . . . . . . . . . . . . . 101 Intermittent Pilot . . . . . . . . . . . . . . . . . . . 102 Direct Ignition . . . . . . . . . . . . . . . . . . . . . 103 Gas Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 Gasket Miller-Gun Mobile Home Furnace . . . . . . . . 148 Duomatic Furnace . . . . . . . . . . . . . . . . . . . 148 Gasket Silicone . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Gate Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Gauge Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Washers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Cutters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Snorkel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 GI Cans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Gloves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 Goggles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Granby Oil Tanks . . . . . . . . . . . . . . . . . . . . . . 150–152 Domestic Tanks . . . . . . . . . . . . . . . . . . . . . 150 Aboveground Skid Tanks . . . . . . . . . . . . . . 150 Underground Tanks . . . . . . . . . . . . . . . . . . 150 ECOGARD . . . . . . . . . . . . . . . . . . . . . . . . . 151 PROTEC20 . . . . . . . . . . . . . . . . . . . . . . . . . 151 Residential . . . . . . . . . . . . . . . . . . . . . . . . . 151 2 in 1 Safety Tank System . . . . . . . . . . . . . 152 Greenshield Oil Tanks . . . . . . . . . . . . . . . . . . . . . . 151 Grills Baseboard . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Sidewall . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Grime-Solv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Ground Rod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Guardian Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 H Hago Nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Hand Cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Hand Tools 6-Drawer Tool Chest . . . . . . . . . . . . . . . . . . 200 Channel Lock . . . . . . . . . . . . . . . . . . . . . . . 203 Cobalt Drill Set . . . . . . . . . . . . . . . . . . . . . . 200 Cordless Drill . . . . . . . . . . . . . . . . . . . . . . . 198 Crimper . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 Cutter Wheels & Parts . . . . . . . . . . . . 201, 202
F.W. Webb Company
v
SECTION
A
Index Hand Tools (continued) Electric Drill . . . . . . . . . . . . . . . . . . . . . . . . . 198 File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 Fitting Brush . . . . . . . . . . . . . . . . . . . . . . . . 203 Flaring Tool . . . . . . . . . . . . . . . . . . . . . . . . . 202 Hacksaw . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 Hex Key Set . . . . . . . . . . . . . . . . . . . . . . . . 203 Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Lever Benders . . . . . . . . . . . . . . . . . . . . . . 202 Mechanics Tool Set . . . . . . . . . . . . . . . . . . 198 Nut Driver / Nut Driver Set (Standard, Metric) . . . . . . . . . . . . . 198, 203 Pipe Cutters . . . . . . . . . . . . . . . . . . . . . . . . 202 Pipe Taps . . . . . . . . . . . . . . . . . . . . . . . . . . 201 Pipe Threaders . . . . . . . . . . . . . . . . . . . . . . 201 Pipe Wrench . . . . . . . . . . . . . . . . . . . . . . . . 201 Pliers / Plier Ser . . . . . . . . . . . . . 198, 199, 203 Prybar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 Radiator Vent Valve L/Key . . . . . . . . . . . . . 203 Radiator Wrench . . . . . . . . . . . . . . . . . . . . . 203 Saws . . . . . . . . . . . . . . . . . . . . . . . . . . 198, 203 Screwdriver / Screwdriver Set . . . . . . 199, 200 Snips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 Socket Set . . . . . . . . . . . . . . . . . . . . . . . . . 198 Spark Lighter . . . . . . . . . . . . . . . . . . . . . . . 203 Swedging Tool . . . . . . . . . . . . . . . . . . . . . . 203 Tape Measure . . . . . . . . . . . . . . . . . . . . . . . 198 Tote Tool Bag . . . . . . . . . . . . . . . . . . . . . . . 200 Tool Box Steel Tool Box . . . . . . . . . . . . . . . . . . . . 200 Plastic Tool Box . . . . . . . . . . . . . . . . . . . 200 Tri-Bender . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Tristand Vises (Portable) . . . . . . . . . . . . . . 201 Tube Bender . . . . . . . . . . . . . . . . . . . . . . . . 203 Tube Cutters . . . . . . . . . . . . . . . . . . . . 201, 202 Utility Knife / Blades . . . . . . . . . . . . . . . . . . 200 Wax Strips (Circular Saw) . . . . . . . . . . . . . 198 Wet/Dry Vac . . . . . . . . . . . . . . . . . . . . . . . . 198 Wire Stripper . . . . . . . . . . . . . . . . . . . . . . . . 198 Wiring Toor . . . . . . . . . . . . . . . . . . . . . . . . . 203 Wrench / Wrench Set . . . . . . . . . . . . . 198, 199 Handpump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Hard Hats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Heat Manager (Gas Boiler) . . . . . . . . . . . . . . . . . . . 37 Heat Motor Zone Valves . . . . . . . . . . . . . . . . . . . . . . 71 Heat Recovery Ventilator . . . . . . . . . . . . . . . . . . . . . . 1 Heating Oil Additive . . . . . . . . . . . . . . . . . . . . . . . . . 15 Heating Oil Treatment . . . . . . . . . . . . . . . . . . . . . . . 15 Heating System Evaluation Forms . . . . . . . . . . . . . 173
vi
F.W. Webb Company
Hercules Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . 11 Hole Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Hose Garden . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Steel Flexible Braided . . . . . . . . . . . . . . . . . 144 Washing Machine . . . . . . . . . . . . . . . . . . . . . 42 Hot Surface Ignition Module . . . . . . . . . . . . . . . . . . 110 Robertshaw . . . . . . . . . . . . . . . . . . . . . . . . 110 White Rodgers . . . . . . . . . . . . . . . . . . . . . . 110 Hot Surface Ignitors . . . . . . . . . . . . . . . . . . . . . . . . 110 Honeywell Media Air Cleaner . . . . . . . . . . . . . . . . . . . 3 Humidifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5, 6, 7 Whole-House Drum Humidifier . . . . . . . . . . . . 5 Bypass Flow-through Humidifier . . . . . . . . . . . 5 Powered Flow-through Humidifier with Humidistat . . . . . . . . . . . . . . . . . . . 5, 6 Bypass Flow-through Humidifier with Humidistat . . . . . . . . . . . . . . . . . 5, 6, 7 Steam Humidifier . . . . . . . . . . . . . . . . . . . . 5, 6 Bypass Humidifier . . . . . . . . . . . . . . . . . . . . 6, 7 Power Humidifier . . . . . . . . . . . . . . . . . . . . 6, 7 Humidity Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Hydronic System Cleaner . . . . . . . . . . . . . . . . . . . . . 14 Hydronic Zone Controls . . . . . . . . . . . . . . . . . . . . . . 70 Zone Valves . . . . . . . . . . . . . . . . . . . . . . . . . 70 Hydrostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 I Indoor Air Quality Tester . . . . . . . . . . . . . . . . . . . . . Ignitor Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . Ignition Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ignition Terminal Kits . . . . . . . . . . . . . . . . . . . . . . . Infrared Thermometer . . . . . . . . . . . . . . . . . . . . . . Instant-Glo Combustion Chambers . . . . . . . . . . . . Insulated Hangers . . . . . . . . . . . . . . . . . . . . . . . . . Inso-Line Strap Hanger . . . . . . . . . . . . . . . Inso-Line & Plain Guide Clips . . . . . . . . . . .
172 141 141 141 166 147 156 156 156
K Kamco . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 Kaowool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Cement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Dry Blanket . . . . . . . . . . . . . . . . . . . . . . . . . 147 Rope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Wet Blanket . . . . . . . . . . . . . . . . . . . . . . . . 147 Killem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 L Ladders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 Lead Sets (industrial & Hard Point) . . . . . . . . . . . . 170 www.fwwebb.com
SECTION
A Leak Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Leak & Pressure Detectors . . . . . . . . . . . . . . 166, 172 Lennox Hand Saws . . . . . . . . . . . . . . . . . . . . . . . . 203 Lennox Drill Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Lennox Blades . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 Light Bulbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 197 Lima . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19–21 Liquid Burnisher . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Line Voltage Zone Valves . . . . . . . . . . . . . . . . . . . . . 69 Low Voltage Transformers . . . . . . . . . . . . . . . . . . . . 36 Low Voltage Zone Valves . . . . . . . . . . . . . . . . . . . . . 69 Low Water Cut-offs . . . . . . . . . . . . . . . . . . . . . . . 49–56 Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Mechanical . . . . . . . . . . . . . . . . . . . . . . . 51, 52 Replacement Parts . . . . . . . . . . . . . . . . . 55, 56 Lubricants . . . . . . . . . . . . . . . . . . . . . . . . . 11, 209, 218 Lynn Products . . . . . . . . . . . . . . . . . . . . . . . . . 147–149 M Magnetic Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Manifolds Copper (ALB) . . . . . . . . . . . . . . . . . . . . . . . . 73 Custom Cut . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Onix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Radiant PEX CrimpRing . . . . . . . . . . . . . 80 Radiant PEX Base Branch . . . . . . . . . . . 80 Stainless Steel . . . . . . . . . . . . . . . . . . . . . . . 81 Accessories . . . . . . . . . . . . . . . . . . . . . . . 81 Pressure Test Kit . . . . . . . . . . . . . . . . . . . 81 Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 End Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Vent-and-purge Assembly . . . . . . . . . . . . . . 81 Circuit Isolation Plug . . . . . . . . . . . . . . . . . . . 81 Circuit Isolation Mini Ball Valve . . . . . . . . . . . 81 Make-up Air System . . . . . . . . . . . . . . . . . . . . . . . . 216 Manometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Mapp Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Marathon Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Mask (Moldex) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Mastercraft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 Maxitrol Regulators . . . . . . . . . . . . . . . . . . . . 111–112 McDonnell & Miller . . . . . . . . . . . . . . . . . . . . . . . 50–58 McDonnell & Miller Parts . . . . . . . . . . . . . . . . . . 55–56 Media Whole House Air Cleaners . . . . . . . . . . . . . 2, 3 Media Replacement Air Filter . . . . . . . . . . . . . . . . . . . 9 Meltdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Midwest Hand Tools . . . . . . . . . . . . . . . . . . . . . . . . 200 Miller Furnace Gaskets . . . . . . . . . . . . . . . . . . . . . 148 Milwaukee Electric Tools . . . . . . . . . . . . . . . . 204, 205
The F.W. Webb Heating Catalog
Index Milwaukee Accessories . . . . . . . . . . . . . . . . . . . . . . . . 210 Drill Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 Saw Blades . . . . . . . . . . . . . . . . . . . . . . . . . 210 Mixing Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Monoflo Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Mono-Flow Tees . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Motors Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Circulator . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Multimeters Analog . . . . . . . . . . . . . . . . . . . . . . . . 169, 198 Clamp On . . . . . . . . . . . . . . . . . . . . . . 165, 169 Adapters . . . . . . . . . . . . . . . . . . . . . . . . 165 Digital . . . . . . . . . . . . . . . . . . . . . . . . . 164, 169 Testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 With Thermometer . . . . . . . . . . . . . . . . . . . 171 N Needle Valve (Self Piercing) . . . . . . . . . . . . . . . . . . . . 7 Nipple Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 Nipple Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 Nipples (Schedule 40) . . . . . . . . . . . . . . . . . . 161, 162 Nozzle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129–132 Nozzle Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Nozzle Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 Nozzle Changer . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 O Odor Neutralizer . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 OEM Replacement Gauge Vial . . . . . . . . . . . . . . . 154 OEM Wireless Fuel Level Monitor . . . . . . . . . . . . . 154 Oil Absorber Mat . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Oil Burner Blower Wheels . . . . . . . . . . . . . . . . . . . 146 Oil Burner Coupling/Accessories . . . . . . . . . . . . . . 146 Oil Burners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Beckett . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Replacement Parts / Accessories . . . . . 135 Carlin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 Replacement Parts / Accessories . . . . . 137 Riello . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 Replacement Parts / Accessories . . . . . 136 Oil Burner Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Oil Burner Testing . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Oil Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Oil De-Aerator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Oil Filter Draining System . . . . . . . . . . . . . . . . . . . . 143 Oil Filter Elements . . . . . . . . . . . . . . . . . . . . . . . . . 143
F.W. Webb Company
vii
SECTION
A
Index Oil Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Fuel Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Refill Cartridges . . . . . . . . . . . . . . . . . . . 143 Spin-On . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Fulflo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Fuel Oil Filter Replacement Cartridges . . . 143 Oil Line, Covered . . . . . . . . . . . . . . . . . . . . . . . . . . 156 Oil Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Oil Primary Control Beckett . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Carlin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Honeywell . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Oil Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Oil Safety Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Oil Tank Accessories . . . . . . . . . . . . . . . . . . . . . . . 153 Oil Tank Fill Adapters . . . . . . . . . . . . . . . . . . . . . . . 153 Oil Tan Gauges . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Oil Tank Patch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Oil Tank Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Oil Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150–152 Oil Valve Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Oil Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Omco Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Onix Manifold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Onix Radiant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 OSV Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 P Pasco Hand Tools . . . . . . . . . . . . . . . . . . . . . . . . . 203 Petite 7 Baseboard . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Petite 9 Baseboard . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Pigtail Siphons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Pipe Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 Pipe Thread Grease . . . . . . . . . . . . . . . . . . . . . . . . . 10 Pipe Thread Sealers . . . . . . . . . . . . . . . . . . . . . . . . . 10 Pocket Thermometer . . . . . . . . . . . . . . . . . . . . . . . 165 Power Tools . . . . . . . . . . . . . . . . . . . . . . . . . . 204, 205 Threading Machines . . . . . . . . . . . . . . . . . . 205 Power Venters . . . . . . . . . . . . . . . . . . . . 211, 219–223 ComboVent . . . . . . . . . . . . . . . . . . . . . . . . . 212 PV Power Venter . . . . . . . . . . . . . . . . . . . . 212 Controi Kits . . . . . . . . . . . . . . . . . . . . . . . . . 213 Replacement Parts . . . . . . . . . . . . . . . 217, 223 Super Lube . . . . . . . . . . . . . . . . . . . . . . . . . 218 Vent Hoods . . . . . . . . . . . . . . . . . . . . . . . . . 213 Wiring Diagrams . . . . . . . . . . . . . . . . . 261–264 Pressure & Vacuum Gauges . . . . . . . . . . . . . . . . . 173 Pressure Reducing & Relief Valves . . . . . . . . . . 46–48 Pressure Reducing Valves . . . . . . . . . . . . . . . . . . . . 48 Pressuretrols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
viii
F.W. Webb Company
Propane Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 ProPress . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 ProPress Fittings . . . . . . . . . . . . . . . . . . . . . . 206, 207 PROTEC20 Oil Tanks . . . . . . . . . . . . . . . . . . . . . . . 151 Pump Beckett CleanCut Fuel Pump . . . . . . . . . . . 145 Danfoss Mini Pump . . . . . . . . . . . . . . . . . . 145 Suntec . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Pump Tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Purge & Balance Valves . . . . . . . . . . . . . . . . . . . . . . 66 R RW Lyall Propane . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Ball Valve . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Fittings . . . . . . . . . . . . . . . . . . . . 122, 123, 124 Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Piping System . . . . . . . . . . . . . . . . . . . . . . . 126 Piping Tools . . . . . . . . . . . . . . . . . . . . . . . . 126 Risers . . . . . . . . . . . . . . . . . . . . . . . . . 123, 125 Tees . . . . . . . . . . . . . . . . . . . . . . . . . . 123, 124 Radiant — Onix Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Barbs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Repair Kits . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Unwinder . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Radiant — PEX Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Sticks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Crimp Fittings . . . . . . . . . . . . . . . . . . . . . . . . 78 Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Radiant — PEX-AL Coils . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Fttings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Radiant CinchClamp . . . . . . . . . . . . . . . . . . . . . . . . . 80 Unwinder . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Radiant SubRay System Header Sticks . . . . . . . . . . . . . . . . . . . . . . . . 82 Sleepers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Corner Sweeps . . . . . . . . . . . . . . . . . . . . . . . 82 Grippers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Aluminum Conduction Roll . . . . . . . . . . . . . . 82 C-Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Radiant Tools Basic Tubing Cutter . . . . . . . . . . . . . . . . . . . 82 Cinch Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
www.fwwebb.com
SECTION
A Radiant Tools (continued) Ratcheting Cinch Tool . . . . . . . . . . . . . . . . . . 82 Crimpall Tool Kit . . . . . . . . . . . . . . . . . . . . . . 82 Foamboard Stapler . . . . . . . . . . . . . . . . . . . . 82 ClipTwister ScrewClip Tool . . . . . . . . . . . . . . 83 Staple Guns & Staples . . . . . . . . . . . . . . . . . 83 Staple Gun Accessories . . . . . . . . . . . . . . . . 83 NailTites . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 LockDown Fasteners . . . . . . . . . . . . . . . . . . 83 Radiator Brushes . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Radiator Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Rags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Raingear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 3-Piece Rainsuits . . . . . . . . . . . . . . . . . . . . 195 PVC Boots . . . . . . . . . . . . . . . . . . . . . . . . . 195 Rayovac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Rectorseal Chemicals . . . . . . . . . . . . . . . . . . . . . . . 13 Relief Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46, 47 Commercial Hot Water . . . . . . . . . . . . . . . . . 47 Safety Relief Valves . . . . . . . . . . . . . . . . . . . 46 Drain Lines . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Hot Water Boiler . . . . . . . . . . . . . . . . . . . . . . 46 Poppet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Steam Boiler . . . . . . . . . . . . . . . . . . . . . . . . . 46 Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 L-Model Line, OPDs, #2 Inlet . . . . . . . . . . . 111 Rubber Seat Poppet Design . . . . . . . . . . . . 112 Maxitrol . . . . . . . . . . . . . . . . . . . . . . . . 111, 112 Robertshaw . . . . . . . . . . . . . . . . . . . . . . . . 112 Add-on Pressure Regulator Kits . . . . . . . . . 112 Pressure Regulator . . . . . . . . . . . . . . . . . . . 112 Registers Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Sidewall . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Replacement Relay . . . . . . . . . . . . . . . . . . . . . . . . . 24 Respirator (Paint Spray) . . . . . . . . . . . . . . . . . . . . . 196 Returns (Floor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Retrofit Pilot Burner Ignition System . . . . . . . . . . . . 94 Rhomar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Riello Oil Burner Parts . . . . . . . . . . . . . . . . . . . . . . 136 Rigid Hand Tools . . . . . . . . . . . . . . . . . . . . . . 201, 202 Rigid ProPressTools & Jaws . . . . . . . . . . . . . . . . . 206 S Safety Hats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Safety Monitors & Detectors . . . . . . . . . . . . . . . . . . 172 Safety Relief Valves . . . . . . . . . . . . . . . . . . . . . . . . . 46 Safety Tools . . . . . . . . . . . . . . . . . . . . . . . . . . 195, 196
The F.W. Webb Heating Catalog
Index Safgard Water Feeder . . . . . . . . . . . . . . . . . . . . . . . 49 Sail Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Saw Blades . . . . . . . . . . . . . . . . . . . . . . . . . . 209, 210 SBG (Sludge Be Gone) . . . . . . . . . . . . . . . . . . . . . . 15 Schedule 40 Nipples . . . . . . . . . . . . . . . . . . . 161, 162 Schedule 40 & 80 Black Pipe . . . . . . . . . . . . . . . . . 163 Scratch Brushes . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 Scully . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Skuttle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Sling Psychrometer . . . . . . . . . . . . . . . . . . . . . . . . 172 Smart Valve System . . . . . . . . . . . . . . . . . . . . . . . . 101 Smoke Candles . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Smoke Test Set . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Snorkel Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Solder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 Solder Accessories . . . . . . . . . . . . . . . . . . . . . 191, 192 Soldering Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Soldering Paste Flux . . . . . . . . . . . . . . . . . . . . . . . 192 Soot Remover Stick . . . . . . . . . . . . . . . . . . . . . . . . . 13 Soot Spray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Soot Saws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Soot Shovel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Speedy Dry Absorbant . . . . . . . . . . . . . . . . . . . . . . . 12 Spirovent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Stack Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Stainless Steel Gas Connectors / Fittings . . . 118–120 Static Pressure Control . . . . . . . . . . . . . . . . . . . . . . 22 Steam Humidifier . . . . . . . . . . . . . . . . . . . . . . . . . . 5, 6 Steam Pressure Control . . . . . . . . . . . . . . . . . . . . . . 32 Stop & Waste Valves . . . . . . . . . . . . . . . . . . . . . . . . 67 SubRay Radiant . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Suction Line Analyzer . . . . . . . . . . . . . . . . . . . . . . . 173 Suntec Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Supply Plenum Sensor . . . . . . . . . . . . . . . . . . . . . . . 24 Switching Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Circulator . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Hydronic . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 PowerPort Cards . . . . . . . . . . . . . . . . . . . . . 34 Power Controls . . . . . . . . . . . . . . . . . . . . . . . 34 T Tank Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163 Tank Drainer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Tank Gauges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Tankless Water Heaters . . . . . . . . . . . . . . . . . . . . . . 76 Tekmar Controls . . . . . . . . . . . . . . . . . . . . . . . . . 38–40 Telescoping Mirrors . . . . . . . . . . . . . . . . . . . . . . . . 133 Tempering/Mixing Valves . . . . . . . . . . . . . . . . . . . . . 66
F.W. Webb Company
ix
SECTION
A
Index Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Ignitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Transformer . . . . . . . . . . . . . . . . . . . . . . . . 141 Test-N-Check Valves . . . . . . . . . . . . . . . . . . . . . . . . 57 Thermal Cutoffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Thermal Relacement Fuses . . . . . . . . . . . . . . . . . . . 18 Thermal Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Thermocouples . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Honeywell . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Johnson Controls . . . . . . . . . . . . . . . . . . . . 105 Robertshaw . . . . . . . . . . . . . . . . . . . . . . . . 104 Thermometer Dial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Digital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 Infrared . . . . . . . . . . . . . . . . . . . . . . . . 166, 171 Pocket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 Thermopile Generators . . . . . . . . . . . . . . . . . . . . . 105 Thermostatic Radiator Actuators . . . . . . . . . . . . . . . 64 Thermostatic Radiator Valves . . . . . . . . . . . . . . 64, 65 Thermostats Digital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Non-Programmable . . . . . . . . . . . . 178–181 Electric Heat Thermostats . . . . . . . . . . . . . 177 Guards . . . . . . . . . . . . . . . . . . . . . . . . 189, 190 Honeywell . . . . . . . . . . . . 174, 177, 179–180, . . . . . . . . . . . . . . . . . . . . . . 184–185, 187–188 Johnson Controls . . . . . . . . . . . . . . . . . . . . 176 Line Voltage Thermostats . . . . . . . . . . 176, 177 Low Voltage Thermostats . . . . . . . . . . 174, 175 Low Voltage Tester . . . . . . . . . . . . . . . . . . . 171 Mercury . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Programmable . . . . . . . . . . . . 24, 40, 182–187 PurePro . . . . . . . . . . . 171, 176, 178, 182–184 Robertshaw . . . . . . . . . . . . 175, 181, 186–187 Subbases . . . . . . . . . . . . . . . . . . . . . . 175, 188 Thread Cutting Oil . . . . . . . . . . . . . . . . . . . . . . 11, 205 Thread Sealants . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Tiger Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Tjerlund Power Venters . . . . . . . . . . . . . . . . . 219–223 TracPipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 CounterStrike . . . . . . . . . . . . . . . . . . . . . . . 113 Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Accessories . . . . . . . . . . . . . . . . . . . . . . . . 116 Underground . . . . . . . . . . . . . . . . . . . . . 117 Bonding Clamp . . . . . . . . . . . . . . . . . . . 116 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Turbo Torch . . . . . . . . . . . . . . . . . . . . . . . . . 191
x
F.W. Webb Company
Transformer Plate Mounted . . . . . . . . . . . . . . . . . . . . . . . 24 17K Electronic . . . . . . . . . . . . . . . . . . . . . . 140 10K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 Electronic Transformer Kit . . . . . . . . . . . . . 140 Universal . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 14K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . 141 TurboTorch Soldering Supplies . . . . . . . . . . . . . . . 191 V V-Belts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Vacuum Cleaners . . . . . . . . . . . . . . . . . . . . . . 194, 198 Accessories & Replacement Parts . . . . . . . 194 Rigid Wet/Dry Vac . . . . . . . . . . . . . . . . . . . 194 Sootmaster . . . . . . . . . . . . . . . . . . . . . . . . . 194 Vacuum Relief Valves . . . . . . . . . . . . . . . . . . . . . . . . 47 Vacuum/Pressure Gauges . . . . . . . . . . . . . . . . . . . 173 Valves (Magnetic) . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Varivents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Vent Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Vent Rite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Ventalarm (Gauges / Signals) . . . . . . . . . . . . . . . . 154 Venting All Fuel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 B Vent . . . . . . . . . . . . . . . . . . . . . . . . . 226–228 B Vent Chimney Kit . . . . . . . . . . . . . . . . . . 230 Chimney Liner . . . . . . . . . . . . . . . . . . . . . . 224 Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 Z-Flex . . . . . . . . . . . . . . . . . . . . . . . . . 224–225 Vermiculite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Viega ProPress Fittings . . . . . . . . . . . . . . . . . 206, 207 Visor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Volt Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 Voltage Tester . . . . . . . . . . . . . . . . . . . . . . . . . . 18, 171 W WAGS (Water & Gas Safety Valve) . . . . . . . . . . . . 103 Washing Machine Hose . . . . . . . . . . . . . . . . . . . . . . 42 Water Absorbant . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Water Feeders . . . . . . . . . . . . . . . . . . . . . . . 49, 52, 53 Alarm/Shut-off Kit . . . . . . . . . . . . . . . . . . . . 103 Electric . . . . . . . . . . . . . . . . . . . . . . . . . . 52, 53 Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Make-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Water Finding Paste . . . . . . . . . . . . . . . . . . . . . 15, 153 Water Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Water Heaters (Tankless) . . . . . . . . . . . . . . . . . . . . . 76
www.fwwebb.com
SECTION
A Watts Radiant Valve Actuator . . . . . . . . . . . . . . . . . . . . . . . . 80 Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Wet Combustion Chambers . . . . . . . . . . . . 148 Windshield Washer Fluid . . . . . . . . . . . . . . . . . . . . . 12 Winter Watchman . . . . . . . . . . . . . . . . . . . . . . . . . . 174 Wire Nuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Wire Staples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Wire BX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Romex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Solid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . 16 Wireless Fuel Level Monitor (OEM) . . . . . . . . . . . . 154 Work Lights . . . . . . . . . . . . . . . . . . . . . . . . . . 197, 198 Work Light Bulbs . . . . . . . . . . . . . . . . . . . . 197 Y Yellow Plastic Gas Pipe . . . . . . . . . . . . . . . . . . . . . 126 Z Z-Flex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224, 225 Z-Vent Special Gas Vent . . . . . . . . . . . . . . . . 224, 225 Appliance Adapters . . . . . . . . . . . . . . . . . . . 225 Zipp & Zipp II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Zone Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 23 Forced Air . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Universal . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Zone Controls Parts . . . . . . . . . . . . . . . . . . . . . . 70, 71 Zone Valve Controls . . . . . . . . . . . . . . . . . . . . . . . . . 71 Zone Valve Thermostat . . . . . . . . . . . . . . . . . . . . . . 71 Zone Valves Honeywell . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Taco . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 White Rodgers . . . . . . . . . . . . . . . . . . . . . . . 70 Technical Information Troubleshooting SV9500 Smart Valve . . . . . . . . . . . . . . . . . 232 SV9501 / SV9502 Smart Valve . . . . . . . . . . 233 Electrical System . . . . . . . . . . . . . . . . 234–235 Fuel System . . . . . . . . . . . . . . . . . . . . 236–238 No Heat With Burner Running . . . . . . 239–240 Bleeding The System of Air . . . . . . . . . . . . 240 Bleeding The System of Air with Zone Valves . . . . . . . . . . . . . . . . . . 240 Testing Combination Controls . . . . . . 241–242 L7224 Series Oil Electronic Aquastat® Controller . . . . . . . . . 243–244 HeatManager Installation & Wiring . . . . 245
The F.W. Webb Heating Catalog
Index
Boiler Controls: Dual Aquastat Multizone . . . . . . . . . . . . 246 Single High-Limit Aquastat . . . . . . . . . . 247 Triple Aquastat (L81224A) . . . . . . . . . . . 248 Low Voltage Thermostat . . . . . . . . . . . . 249 R7184 Series Primary Controls . . . . . 250–251 S9200U1000 Universal Hot Surface Ignition Integrated Furnace Control . . . . . . 252–255
Technical Tips Carlin Ignitor Testing Procedure . . . . . . . . . 256 Helpful Tips . . . . . . . . . . . . . . . . . . . . . . . . . 257 Adding Antifreeze to the System . . . . . . . . 258 TACO 00 Circ . . . . . . . . . . . . . . . . . . . . . . . . . . 259 3 Speed Circulator . . . . . . . . . . . . . . . . . 259 110-120 . . . . . . . . . . . . . . . . . . . . . . . . . 260 Quick Pipe Sizing Table . . . . . . . . . . . . . 260 Wiring Diagrams . . . . . . . . . . . . . . . . . 261–264 Sizing Expansion Tanks . . . . . . . . . . . . . . . 265 Sizing the Boiler to the Radiation . . . . . . . . 266 Duct Sizing . . . . . . . . . . . . . . . . . . . . . . . . . 267 Oil Tank Chart . . . . . . . . . . . . . . . . . . . . . . . 268 Balancng One-Pipe Steam Systems . . . . . 269 Insulating Steam Pipes . . . . . . . . . . . . . . . . 270 Hartford Loops . . . . . . . . . . . . . . . . . . 271–272 Primary-Secondary Pumping . . . . . . . . . . . 273 Replacing a Steam-Heating Boiler . . . 274–275 Converting from Steam to Hot Water . 276–277 SR501 Switching Relay Wiring . . . . . . . . . . 278 SR504/506 Switching Relay . . . . . . . . . . . . 278 ZVC403/405 with Sump Pump . . . . . . . . . . 279 ZVC404/406 with Sump Pump . . . . . . . . . . 279 SR501 Switching Relay Wiring . . . . . . . . . . 280 SR504/506 Switching Relay . . . . . . . . 280–281 Cross Reference Expansion Tanks . . . . . . . . . . . . . . . . . . . . 282 Electronic Transformers . . . . . . . . . . . . . . . 282 Transformers . . . . . . . . . . . . . . . . . . . . . . . 283 Gas Valves Selection Guide . . . . . . . . 284–285 SmartValve Control Systems Selection Guide . . . . . . . . . . . . . . . 286–287 Ignition Modules Selection Guide . . . . 288–289 Universal Electronics Fan Timer OEM Replacement Guide . . . . . . . 290–291 Oil Primaries Selection Guide . . . . . . . 292–293 Multi-Function Aquastat Selection Guide . . . . . . . . . . . . . . . 294–295
F.W. Webb Company
xi
71 Convenient Locations
back coverB:Layout 1
5/16/08
1:54 PM
Page 1
160 Middlesex Turnpike Bedford, MA 01730 781-272-6600
DEALERS CHOICE Only F.W. Webb’s
Solves your inventory problems.
We adapt to you Stock automatically replenished Eliminate back orders
Gives you a competitive advantage.
Reduce cost Improves productivity Control inventory
It’s YOUR Choice!
Use your part #’s or ours You control the process We inventory so you don’t have to
3/2008—5000SG—CT0010