73 Convenient Locations MAINE
MASSACHUSETTS
138 Leighton Road P.O. Box 5008 207.623.2521 800.322.4700 Fax: 207.622.2533
43 Sword Street Auburn Industrial Park 508.757.9322 800.872.0211 Fax: 508.757.8981
180 Olde Canal Drive 978.937.9322 800.642.9322 Fax: 978.937.5522
Bangor 04401
Bedford 01730
580.584 Broadway 781.322.7111 800.963.7111 Fax: 781.324.7773
Biddeford 04005
Bellingham 02019
Augusta 04330
67 Target Industrial Circle 207.947.6905 800.432.7371 ME only Fax: 207.947.8211 22 Landry Street 207.282.7558 800.443.0505 Fax: 207.282.0299 Caribou 04736
420 Main Street 207.498.2526 800.339.3029 Fax: 207.498.2137 Ellsworth 04605
9 Buttermilk Road 207.667.9322 888.882.9322 Fax: 207.664.0201 Lewiston 04240
9 Forrestall Street P.O. Box 2546 207.784.4575 800.252.2000 Fax: 207.784.4205 S. Portland 04106
150 Postal Service Way 207.772.8364 800.482.0791 ME only Fax: 207.773.4571 Rockland 04841
22 Merrill Drive 207.594.6200 800.287.0015 Fax: 207.594.9185 West Bath 04530
P.O. Box 612 Bull Rock Bridge Road 207.442.7990 800.427.7990 Fax: 207.442.8377 Winslow 04901 Mail to: P.O. Box
1569 Waterville, ME 04903 Ship to: 37 Heywood Rd. Winslow, ME 04901 800.533.1172 F. W. Webb
207.872.5522 800.640.9322 Fax: 207.872.8207 Kennebec Supply
207.873.2111 Fax: 207.873.0152 Kentrol / Sevco
207.873.7741 800.452.1928 Fax: 207.873.2945 Webb Pump
207.873.7741 800.452.1928 Fax: 207.873.2945
Auburn 01501
160 Middlesex Turnpike 781.273.9322 800.221.9322 Fax: 781.270.0208 37 South Maple Street 508.966.4999 Fax: 508.966.1999 Boston 02118
237 Albany Street 617.482.8387 Fax: 617.423.7858 Brockton 02301
60 Industrial Boulevard 508.580.8310 800.544.9322 Fax: 508.584.6418 Canton 02021
152 Will Drive 781.828.5559 Fax: 781.828.8060 Dedham 02026
45 Commerce Way 781.329.6200 866.684.9322 Fax: 781.329.3531 Fitchburg 01420
Lowell 01851
Malden 02148
Methuen 01844
98 Lindbergh Avenue 781.325.7041 866.548.9322 Fax: 781.325.7051 Utilities Supply Co. (USCO)
781.395.9023 800.343.7555 Fax: 781.395.2329
New Bedford 02745
915 Church Street 508.995.9533 888.354.0048 Fax: 508.985.0934
Northampton 01060
135 Industrial Drive 413.586.8100 800.282.7721 MA only Fax: 413.586.6280 Pittsfield 01201
35 Commercial Street 413.448.8205 800.578.9322 Fax: 413.442.2251
135 Falulah Street 978.345.4121 800.322.0899 Fax: 978.343.3749
Plymouth 02360
Gloucester 01930
Salem 01970
51 Great Republic Dr. Blackburn Industrial Pk 978.283.7800 Fax: 978.281.7016 Greenfield 01301
340 Chapman Street 413.773.3644 800.564.3644 Fax: 413.773.8205 Haverhill 01835
270 Neck Road Ward Hill Business Park West 978.374.8448 800.521.7499 Fax: 978.373.7723 Hingham 02043
45 Pond Park Road 781.749.9322 Fax: 781.740.4652 Hyannis 02601
108 Breeds Hill Road 508.775.3890 800.352.3159 MA only Fax: 508.778.0409
3 Collins Avenue 508.830.4666 Fax: 508.830.0481 295 Bridge Street 978.744.6550 800.345.5025 Fax: 978.744.1444 Springfield 01104
153 Plainfield Street 413.781.1700 800.660.3141 Fax: 413.781.1705 Sturbridge 01566 Pipe Depot
9 Picker Road 508.347.3342 Fax: 508.347.4967 Woburn 01801
50 Everberg Road 781.933.1804 800.253.7838 Fax: 781.933.3528 HVAC Controls
781.933.1804 800.341.0110 Fax: 781.933.3528
NEW HAMPSHIRE
CONNECTICUT
NEW YORK
46 Henniker Street 603.223.6580 888.508.0050 Fax: 603.223.6585
182 Route 32 860.642.9081 888.642.9086 Fax: 860.642.9082
17 Erie Boulevard 518.472.9322 800.432.9322 Fax: 518.472.9399
Concord 03301
Franklin 06254
Albany 12204
Dover 03820
Hartford 06114
Binghamton 13904
Exeter 03833
Hartford 06114 Victor
Cazenovia 13035 Kentrol/Sevco – Control Equipment Corp. (CEC) Mail to: PO Box 330 Ship to: One Carriage
10 Sumner Drive 603.749.3100 800.582.7196 Fax: 603.749.5572 18 Continental Drive 603.772.3441 888.993.9322 Fax: 603.772.1866 Gilford 03249
302 Hounsell Avenue 603.524.9322 800.345.1771 Fax: 603.527.1554 Keene 03431
420 Winchester Street 603.357.1877 800 235.1218 NH only Fax: 603.357.7276 Lebanon 03766
55 Etna Road 603.448.1980 800.322.8707 Fax: 603.448.6057 Madison 03849
1173 Conway Road 603.367.8852 800.852.9203 Fax: 603.367.4647 Manchester 03103
25 Union Street 603.668.6488 800.789.6488 Fax: 603.668.7277 Nashua 03062
7 Redmond Street 603.883.3355 800.462.1440 NH only Fax: 603.595.7733
150 Locust Street 860.522.9322 800.252.9322 Fax: 860.246.3718 200 Locust Street 860.722.2433 800.243.9360 Fax: 800.274.2004 New Haven 06519
650 Ella T. Grasso Blvd. 203.865.6124 866.416.9322 Fax: 203.624.5027 Waterbury 06708
737 Bank Street 203.574.5959 800.572.6479 Fax: 203.753.2245 VERMONT Barre 05641
10 Clark Road 802.479.3373 800.244.5044 VT only Fax: 802.479.2932 Bennington 05201
240 East Road 802.447.2312 800.821.9506 Fax: 802.447.1481
Brattleboro 05301
231 John Seitz Dr. Exit 1 Industrial Park 802.257.4316 800.821.9511 Fax: 802.257.7690 Rutland 05701
RHODE ISLAND
3091 Cold River Road 802.775.1922 800.622.4365 Fax: 802.773.7044
3 Slater Road
Springfield 05156
Cranston 02920
Pipe, Valves, Fittings
401.463.3741 800.795.6390 Fax: 401.463.4103
Webb Pump Webb Piping Products
401.463.4108 866.850.7867 Fax: 401.463.6056 Webb Bio–Pharm
401.463.4176 877.932.2246 Fax: 401.463.4160 Warwick 02888
101 Jefferson Blvd. 401.463.8339 888.225.6850 Fax: 401.463.8661
3 Charlestown Road 802.885.8127 800.872.5303 Fax: 802.885.2685 St. Albans 05478
5 Franklin Park West 802.527.0531 800.696.3763 Fax: 802.524.2093 St. Johnsbury 05819
2409 Portland Street 802.748.8101 800.872.8028 Fax: 802.748.3478 Williston 05495
80 Park Avenue 802.879.5155 800.696.0340 Fax: 802.879.4848
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
62 Griswold Street 607.724.3170 888.593.9322 Fax: 607.724.4369
Place Lane 315.655.9700 Fax: 315.655.9701
Canandaigua 14424
5297 Parkside Drive Suite 425 585.393.9322 800.828.8824 Fax: 585-393-6500
Newburgh 12550-6405
600 Corporate Blvd. 845.567.0242 877.494.9322 Fax: 845.567.6019 Plattsburgh 12901
7327 Rte 9 518.562.2575 800.622.9322 Fax: 518.562.0117
Queensbury 12804
3 Highland Avenue 518.792.1316 800.826.0326 Fax: 518.792.1335 Syracuse 13211
6792 Townline Road 315.476.9322 800.262.9222 Fax: 315.472.4139 Utica 13501
415 Broad Street 315.724.3191 Fax: 315.724.4067
To our Valued Customers, We are pleased to bring you our 2011 Heating products catalog. If you’ve used our catalogs in the past, you’ll notice that something has changed with this edition. We’ve bundled our traditional heating catalog and our Victor gas catalog providing you with an easy to use, single source for all your Oil, Natural and LP Gas product needs. Inside you’ll find hundreds of product pictures, descriptions, specifications, and Webb part numbers as well as a wealth of technical and cross reference info. The numbers, when used with our WebbConnect online ordering system, will give you inventory status, pricing and ordering capability, all with a click of the mouse. With over 70 locations throughout New England and New York, you are never far from the products in this catalog. And, of course, we offer free delivery if that best suits your needs. All of our locations are listed to the left for easy reference. Please don’t hesitate to call the location most convenient to you for help at any time. Need to speak to an LP Specialist at Victor? Simply call 800-243-9360. Sincerely,
Jeff Pope President F.W. Webb Company
Easy Ordering ORDER ONLINE at: victormfg.com Charge to your account, or we accept MasterCard, VISA and Business American Express. Victor is in no way responsible for errors, omissions or typos in the Heating Catalog. Furthermore, the pictures, ads and editorials contained in the Heating Catalog are copyrighted and cannot be used in full or any part without express permission of the publisher.
GAS EQUIPMENT Victor is the Northeast’s leading distributor of these premier gas equipment manufacturers.
GAS EQUIPMENT CATALOG Table of Contents Section 1 2
Page Regulators & Accessories
Regulators, Regulator Reliefs, Pigtails, POL Fittings
1
Valves & Accessories
30
3 Meters/Meter Accessories
86
4
90
Cylinder and Service Valves, Multivalve Assemblies, Pressure Relief Valves & Relief Valve Manifolds, Globe & Angle Valves, Ball Valves, Excess Flow Valves, Filler Valves, Vapor Equalizing Valves, Internal Valves & Accessories, Adapters, Connectors & Fittings, Miscellaneous Equipment, Diagrams, Repair Kits Meters, Meters Bars, Manifolds, Accessories
5 6 7
Cylinders, Tanks & Accessories
ASME & Dot Cylinders, Motor Fuel Cylinders, Cylinder Cabinets, Cylinder Inverters, Scales, OPD Tools, Hand Trucks, ASME Tanks, ASME Replacement Parts, CAD Welding & Galvanic Protection
Paint & Supplies
102
Gauges
107
Gas Pipe, Tubing & Fittings
118
Tank Paint & Supplies, Decals & Signs Cylinder Gauges, Tank Gauges, Pressure Gauges TracPipe, Counter Strike, Copper Tubing, Coated Copper Tubing, Underground PE Pipe, Bulk Hose, Sediment Traps, Lyco Fittings, Continental Fittings, Dormont Connectors, SAE Fittings, Barbed Hose Fittings, Black Iron Fittings, Forged Steel Fittings
continued 4
GAS EQUIPMENT CATALOG Table of Contents (continued) Section 8
Page Gas Heating
149
Pumps/Compressors
174
Miscellaneous Equipment
205
Tools & Chemicals
211
13
Appendices
213
Index
9
10 11
Ignition Modules, Ignitors, Water Heater Controls, Gas Valves, Retrofit Kits, Water Safety Valves, Thermocouple & Thermopiles, Gas Orifices, Aluminum Tubing, Pilots, Hot Surface Igniters, Gas Valves Pressure Regulators Positive Displacement Meters, Hose Reels, Flex Connectors, Strainers, Swivel Connectors, Compressor Kits, Pump Station Kits, Propane Pumps, Selection Tables, Bypass Valves, Motors, Repair Parts Gas Conversion Burners, Vaporizers, Gas Lights, Gas Outlet Boxes Electrical Meters & Testers, Thermometers, Leak Detectors, Pressure Detectors, Carbon Monoxide Detectors, Underground Pipe Locators, Vacuum Cleaners, Gloves, Hand Tools, Power Tools, Flashlights, Lubricants, Chemicals, Test Kits
i
SECTION
1
Regulators Compact High Pressure First Stage Regulator
Inlet connection
MFR# LV3403TR
LV3403TR
1/4” F. NPT
outlet orifice connection size 1/2” F. NPT
1/4”
factory delivery pressure
bonnet vent position
vapor capacity btu/hr. propane*
Webb#
10 PSIG
Over Outlet
1,500,000
162774
* Maximum flow based on 15 PSIG inlet pressure and 8 PSIG delivery.
High Pressure First Stage Regulators LV4403 Series
Provides accurate first stage regulation in two-stage bulk tank systems. These regulators handle vaporization of tanks up to 1200 gallons. Reduce tank pressure to an intermediate pressure of 5 to 10 PSIG. Also used to supply high pressure burners for applications like industrial furnaces or boilers. Also incorporated in multiple cylinder installations. LV4403TR9
Inlet connection
MFR# LV4403SR4
outlet connection
orifice size
5
1-5
10
5-10
187110
5
1-5
162780
10
5-10
5
1-5
187109
10
5-10
162782
1/2” F. NPT
LV4403SR9
1/4”
LV4403TR9
F. POL
LV4403SR96
3/4” F. NPT
LV4403TR96
vapor capacity btu/hr. propane**
Adjustment range* (psig)
1/2” F. NPT
LV4403TR4
inTEGRAL relief included
factory delivery pressure
Webb# 187108
Yes
2,500,000
162781
* When used for final stage pressure control, must either incorporate integral relief valve or separate relief valve should be specified in accordance with NFPA Pamphlet 58. ** Maximum flow based on inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 20% lower than the setting.
Second Stage Regulator for 2 PSIG Systems LV4403Y & LV5503Y Series
Designed to reduce first stage pressure of 10 PSIG down to 2 PSIG. Systems that utilize this regulator use smaller than normal piping inside of the building. A special final stage regulator, not the appliance regulator, is required to reduce this intermediate 2 PSIG pressure down to 11” w.c. LV4403Y4 MFR#
Inlet connection
outlet connection
orifice size
LV4403Y4
1/2” F. NPT
1/2” F. NPT
1/4”
LV4403Y46R*
1/2” F. NPT
3/4” F. NPT
1/4”
LV5503Y6
3/4” F. NPT
3/4” F. NPT
1/4”
LV5503Y8
3/4” F. NPT
1” F. NPT
9/32”
ADJUSTMENT RANGE 2 PSIG at 10 PSIG Inlet 2 PSIG at 10 PSIG Inlet 2 PSIG at 10 PSIG Inlet 2 PSIG at 10 PSIG Inlet
bonnet vent position
vapor capacity btu/hr. propane**
Webb#
Over Inlet
1,000,000
192612
Over Inlet
1,000,000
250285
Over Inlet
2,200,000
250286
Over Inlet
2,200,000
250287
* Backmount Design ** Maximum flow based on 10 psig inlet pressure and 2 psig delivery pressure.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
1
1 regulators & accessories
Ideal for use as a first stage regulator on any domestic size ASME or DOT container in propane gas installations requiring no more than 1,500,000 BTU’s/hr. These regulators are factory set to reduce tank pressure to an intermediate pressure of approximately 10 PSIG.
SECTION
1
Regulators
Low Pressure Second Stage Regulators Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 11” W.C. Ideal for medium commercial installation, multiple cylinder installations and normal domestic loads.
LV4403B66R
Inlet connection
MFR# LV4403B4
outlet connection
orifice size
factory delivery pressure
ADJUSTMENT RANGE
vent position
vapor capacity btu/hr. propane
1/2” F. NPT
LV4403B46
162775
1/2” F. NPT
162776
LV4403B46R* LV4403B66
#28 Drill
3/4” F. NPT
LV4403B66R*
1” W.C. at 10 PSIG Inlet
935,000 9” to 13” W.C.
Over Inlet
162777 162778 162779
3/4” F. NPT
LV4403B66RA**
Webb#
1,000,000
LV4403B66RAB***
262352 262353
*Backmount Design. **90º Body. ***90º Body with Brackett.
Large Low Pressure Second Stage Regulators Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure. Ideal for larger commercial and industrial applications, multiple cylinder installations and large domestic systems.
LV5503B4
MFR#
Inlet connection
LV5503B4
1/2” F. NPT
LV5503B6
3/4” F. NPT
LV5503B8
outlet connection
orifice size
3/4” F. NPT
1/4”
1” F. NPT
9/32”
LV6503B14
11/2” F. NPT
11/2” F. NPT
LV6503B16
2” F. NPT
2” F. NPT
factory delivery pressure
11” W.C. at 10 PSIG Inlet
5/8”
ADJUSTMENT RANGE
BONNET vent position
9” to 13” W.C.
Over Inlet
81/2” to 14” W.C.
—
vapor capacity btu/hr. propane 1,600,000
Webb# 162783 162784
2,300,000
187111
8,000,000
241847
9,750,000
243018
Low Pressure Second Stage Tobacco Barn Regulator Especially developed for drying barns in the tobacco industry. The LV5503G regulator will supply steady and constant flow of fuel to as many as 12 to 20 burners throughout the barn. LV5503G4
MFR# LV5503G4
2
Inlet connection 1/2” F. NPT
outlet connection 3/4” F. NPT
Gas Equipment Catalog
orifice size 1/4”
factory delivery pressure 15” W.C. at 15 PSIG Inlet
ADJUSTMENT RANGE
BONNET vent position
vapor capacity btu/hr. propane
Webb#
8” to 18” W.C.
Above Inlet
1,750,000
193313
victormfg.com
SECTION
1
Regulators Compact Twin Stage Regulators
1
This compact two-stage regulator is designed to reduce container pressure down to 11” W.C. or 2 psi delivery pressure. It is ideal for “on-site” cylinder applications, mobile homes and average domestic service including small ASME and 100 to 420 pound DOT cylinders.
Inlet connection
MFR# LV404B4 LV404B4V9
1/4” F. NPT
LV404B46
outlet connection
orifice size
factory ADJUSTMENT RANGE delivery pressure 2nd stage
1/2” F. NPT 3/4” F. NPT
LV404B9
.219
1/2” F. NPT
LV404B9V9
F. POL
LV404B96
11” W.C. at 100 PSIG Inlet
9” to 13” W.C.
3/4” F. NPT 1/2” F. NPT
LV404Y9
2 PSI
1.8 to 2.5 PSI
accessories 1st stage vent pipe-away
BONNET vent position 1st stage
BONNET vent position 2nd stage
Down
Over Outlet
162787
9 o’clock
9 o’clock
162788
Down
Over Outlet
Down
Over Outlet
9 o’clock
9 o’clock
Down
Over Outlet
Down
Over Outlet
capacity btu/hr. propane**
Webb#
162789
525,000
404PE
187105 214088 187106
800,000
359411
regulators & accessories
LV404B4
Compact Twin Stage Regulators The compact twin-stage regulator is designed to reduce container pressure down to 11” w.c. delivery pressure. It is ideal for “on site” container applications such as homes, mobile homes and cottages for average domestic service; including small ASME tanks and 100-420 pound DOT cylinders. LV404B34
LV404B39 accessories
Inlet connection
MFR# LV404B34
1/4” F. NPT
LV404B39
F. POL
LV404B34V9
1/4” F. NPT
LV404B39V9
F. POL
outlet connection 1/2” F. NPT
orifice size .100
factory delivery pressure 11” W.C. at 100 PSIG Inlet
ADJUSTMENT RANGE 2nd stage
BONNET vent position 1st stage
BONNET vent position 2nd stage
Rear
Over Outlet
Left
9 o’clock
9” to 13” W.C.
capacity btu/hr. propane**
1st stage vent pipeaway
2nd stage vinyl cover
bracket
162785 450,000
404PE
2302-55
191088
2302-31
162786 202171
Twin Stage Automatic Changeover Regulators These combination automatic changeover, two stage regulators are especially suitable for homes, mobile homes, cottages, construction and other portable two cylinder installations. Empty containers may be replaced without interrupting customer’s gas service. 7525B
MFR# 7525B23 7525B4
Service & reserve indicator Integral
inlet connections 1/4” Inverted Flare
outlet connections 1/2” F. NPT
factory delivery pressure* 11” W.C.
adjustment range 9” to 13” W.C.
Webb#
bonnet vent position Over Outlet
bracket included
capacity btu/hr. propane**
2302-31
200,000
162790
2503-22A
450,000
162792
Webb#
* Set at 100 PSIG inlet pressure. ** Maximum flow based on 25 PSIG inlet pressure and 9” water column delivery pressure.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
3
SECTION
1
Regulators
Automatic Changeover Regulator Outfits These outfits contain the equipment required to provide automatic changeover regulation.
7523B4
automatic changeover regulator included
MFR# 5726B23
7525B23
5727B23
7525B23
5744B4
7526B4
5745B4
7525B4
inlet 1/4”
Inverted Flare
outlet 1/2” F. NPT
pigtails included-2
pigtail sizes
912FA20
11/8” POL
912FS20
7/8” POL
912FA20
11/8” POL
912FS20
7/8” POL
bracket included
capacity btu/hr. propane
2312-31
200,000
2503-22
450,000
webb# 162794 162795 186861 186862
7523B23
Compact Regulators These compact regulators are designed for smaller outdoor grills and fish cookers. It is intended for use on small portable appliances that use 100,000 BTU’s/hr. or less. It may not be used on fixed pipe systems per NFPA 58, 1995 edition.
302V
302
MFR#
TYPE
302 302V9LS 302VW
Single Stage
Soft POL Without Orifice Hard Nose
PIGMEGR-766
Vent Port POL Hand Wheel 90º With QCC 1
PIGMEFMCULH
1/4” With QCC 1
302VW
4
OUTLET CONNECTION
ORIFICE SIZE
ADJUSTMENT RANGE
BONNET VENT POSITION
VAPOR CAPACITY BTU/HR. PROPANE
Small Vent Above Inlet
1/4” F. NPT
302V9 302V9
INLET CONNECTION
FACTORY DELIVERY PRESSURE
86837 273820
Drip Lip at 9 o’clock 3/8” F. NPT
Gas Equipment Catalog
No. 50 Drill
11” W.C. at 100 PSIG Inlet
162715 125,000
9” to 13” W.C. 9 o’clock Vent
WEBB#
273820 275124 186839 362733
Straight
362734
victormfg.com
SECTION
1
Regulators High Pressure Pounds-to-Pounds Regulator
1
Industrial/Commercial 597FA-D
Adjustment Method
MFR#
597FA 597FB 597FC 597FD
Tee Handle
Inlet connection
outlet connection
1/4” F. NPT
Recommended delivery PRessure Range (PSIG)
capacity determine at Set pressure of psig
capacity btu/hr. propane
Webb#
1-15 10-30 20-45 40-100
10 20 30 60
1,750,000 3,000,000 3,500,000 4,500,000
162716 162717 162718 162719
1/4” F. NPT
High Pressure Pounds-to-Pounds Regulators Commercial/Industrial
Designed to reduce LP gas and anhydrous ammonia container pressures to between 3 and 125 PSIG. Precision-built with a multi-million BTU capacity, the 1580M Series is perfect for such big, tough jobs as crop dryers, asphalt batch mixing plants, road building “tar wagons”, heat treating and other large industrial and commercial loads. 1584MW
MFR#
AA1582MW AA1582ML AA1582MH
Service
Adjustment Method
NH3
Inlet & outlet connection 1/4” F. NPT
1584MN 1584ML
LP-Gas 1/2” F. NPT
1584MH AA1584MW AA1584ML AA1574MH
NH3
1586MN 1586ML
Tee Handle LP-Gas 3/4” F. NPT
1586MH AA1586MW AA1586ML AA1586MH
1588MH
LP-Gas
3-25 20-50 45-125
1” F. NPT
Width
23/16”
height (max.)
capacity determine at Set pressure of psig
4”
20 30 60
3-30
20
25-50
30
45-125
215/16”
47/8”
60
3-25 20-25 45-125
20 30 60
3-30
20
25-50
30
45-125
60
3-25 20-50 45-125
NH3
1588MN 1588ML
Recommended delivery PRessure Range (PSIG)
31/2”
7”
20 30 60
3-30
20
25-50
30
45-125
60
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
capacity
Webb#
2,100 CFH NH3 2,400 CFH NH3 2,600 CFH NH3 7,000,000 BTU/hr. LPG 7,500,000 BTU/hr. LPG 8,000,000 BTU/hr. LPG 4,500 CFH NH3 4,800 CFH NH3 5,100 CFH NH3 11,000,000 BTU/hr. LPG 12,000,000 BTU/hr. LPG 14,000,000 BTU/hr. LPG 7,000 CFH NH3 7,700 CFH NH3 8,900 CFH NH3 11,000,000 BTU/hr. LPG 12,000,000 BTU/hr. LPG 14,000,000 BTU/hr. LPG
187087 187086 187085 162800 162799 186810 187089 162412 189234 162802 162801 189126 162414 162413 189235 162804 250280 162803
5
regulators & accessories
Designed to reduce propane gas container pressure down to between 3 and 100 PSIG. Ideal for liquid or vapor service, they can be used in a variety of applications including salamander heaters, weed burning torches, fish cookers, tar pot heaters, and other industrial type services.
SECTION
1
Regulator Accessories High Pressure/High Temperature Pounds-to-Pounds Industrial/Commercial
Designed to reduce LP-Gas container pressures to between 3 and 50 PSIG. Ideal for crop drying, heat treating, asphalt batch mixing and other large industrial and commercial load application utilizing high temperature LP-Gas or high temperature atmosphere under conditions up to 300°F.
X1584MW
MFR#
X1584MN X1584ML X1586MN X1586ML
Services
Adjustment Method
Inlet & outlet connection
Recommended delivery pressure range (PSIG)
Capacity determined at set pressure of psig
capacity btu/hr. propane
Webb#
3-20 25-50 3-30 25-50
20 30 20 30
7,000,000 7,500,000 11,000,000 12,000,000
190688 190687 250279 250290
1/2” F. NPT
LP Gas
Tee Handle 3/4” F. NPT
High Pressure Pounds-to-Pounds Regulator Accessories Industrial/Commercial
Designed for use as a relief valve on first stage regulators that comply with NFPA 58 2.57.5 exception: “first stage regulators with a rated capacity of more that 500,000 BTU/hr. shall be permitted to have a seperate relief valve. 3139
MFR#
Set pressure
Regulator settings
3139-18 3139-26 3139-38
18 PSIG 26 PSIG 38-PSIG
10 PSIG 16 PSIG 20 PSIG
connection size 1/4” M. NPT
height 227/32”
width 11/16”
flow capacity at 120% of set pressure (SCFH PRopane)
Webb#
1357* 1725** 2304***
266443 266437 315791
* Flow recorded at 21.6 PSI inlet pressure for this valve. ** Flow recorded at 31.2 PSI inlet pressure for this valve. *** Flow recorded at 45.6 PSI inlet pressure for this valve.
Victor/F.w. Webb offers webbConnect! you can order, check current pricing and inventory 24/7!
6
Gas Equipment Catalog
victormfg.com
SECTION
1
Regulator Accessories Copper Pigtails
MFR#
Connections
Approx. Length
tube
7/8” hex short nipple
11/8” hex long nipple
Webb#
Alt Marshall PIG#
Webb# —
912PS12
12”
188575
—
912PS20
20”
162812
—
—
30”
—
PIG1664-30
186531
912PS36
36”
162813
—
—
912PS48
48”
162814
—
—
912FS12
12”
216766
PIG1665-12
186532
162806
—
—
275012
—
—
162807
—
—
—
PIG1665-48
186535
12”
162808
PIG1663-48
186530
20”
162809
—
—
36”
188577
—
—
—
PIG1669-48
186539
912PS30
912FS20 912FS30
M. POL X M. POL
1/4” Inverted Flare X M. POL
912FS36 — 912JS12 912JS20 912JS36 —
POL X 1/4” Inverted Flare 1/4”
M. NPT X M. POL
—
48”
1/4”
POL X 1/4”
48” 20”
162810
—
—
M. POL X M. POL
36”
275011
PIG1660-36
186525
162811
—
—
162805
—
—
912PA48 912FA20
7/8”
30” 36”
912PA20 912pa36
20”
—
—
48” 1/4” Inverted
Flare X M. POL
11/8”
20”
913PS05
5”
273819
—
—
913ps12
12”
202603
—
—
913ps20
20”
188582
—
—
30”
250283
pig1680-30
186544
250284
—
—
188581
—
— —
913ps30
M. POL X M. POL
913ps36
36”
913ps48
48”
913js05a
5”
186999
—
12”
250282
—
—
20”
—
pig1684-20
186547
20”
187000
pig1679HP-20
186549
913js12 — 913s20
90º Pre Bent POL X 1/2 MPT 1/4” M. NPT X M. POL
3/8”
7/8”
—
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
7
1 regulators & accessories
912JS20
Pigtails are available in a variety of connections, sizes and styles. Care should always be taken in selecting the proper pigtail for a particular application. Note: Engineered Controls International, Inc., recommends a new pigtail be installed with every new and replaced regulator.
SECTION
1
Regulator Accessories Patented Pigtail Products
Applicatoin: Pigtails are available in a variety of sizes and styles. Care should always be taken in selecting the proper pigtail for a particular application. Patented presto-tap pigtail part numbers 1/4” Tube connections M.POL x M.POL
1/4” Inverted Flare x M.POL 1/4” M. NPT x M.POL
Fugitive emission reduction Webb #
approx. length
7/8” hex short nipple
pigtail length
1/4” tube
3/8” tube
12”
PT912PS12
12”
80%
91%
244167
20”
PT912PS20
20”
82%
NA
433019
48”
PT912PS48
48”
88%
NA
433020
20”
PT912FS20
12”
PT912JS12
20”
PT912JS20
3/8” TUBE
approx. length
7/8” hex short nipple
M.POL x M.POL
12”
PT913PS12
1/4” M. NPT x M.POL
12”
PT913JS12
connections
Pigtails
Patented Tank Pressure Fittings Application: The patented Presto-Tap LDS2000RV is designed to obtain pressure readings and perform system leak testing using tank pressure without ever breaking the system. Meets NFPA 54 & 58 requirements regarding excess flow. Compatible with all Presto-Tap® gauge products when used at correct locations
Patented tank pressure fitting part # LDS2000RV
thread
core
body wrench flat
cap wrench flat hex
#54 orifice
application
1/8 NPT
Viton
7/16
9/16
Yes
Tank Pressure
Webb # 244172
Regulator & Appliance Fitting Application: The RVL low pressure fitting is designed to obtain pressure readings at first and second sage regulators. Compatible with all Presto-Tap® gauge products when used at correct locations.
regulator & appliance fitting part # RVL
8
thread
core
body wrench flat
cap wrench flat hex
#54 orifice
application
1/8 NPT
Viton
7/16
9/16
No
Low Pressure
Gas Equipment Catalog
Webb # 433023
victormfg.com
SECTION
1
Regulator Accessories Presto-Tap® High Pressure Gauge Products & Accessories
1
part numbers
gauge bleeder (244170)
6800-90
90° quick adapter (244173)
straight quick adapter (433013)
X
X
X
244174
X
433007
6800-B90
X
X
X
6800-BH90
X
X
X
6800D-90
glycerin filled gauge (433005)
dry gauge (433004)
belt loop holster (433012)
belt Loop Holster (379916)
X
webb #
433018
X
X
X
433010
X
433010
6800D-B90
X
X
X
6800D-BH90
X
X
X
regulators & accessories
Application: 300# Gauge is used to obtain pressure readings and perform leak tests at tank pressure locations prior to 1st stage regulators such as Presto-Tap® pigtails and RegO “Ready To Go Valves”.
X
433011
Presto-Tap® Low Pressure Gauge Products & Accessories Application: 30# Gauge is used to perform leak tests downstream of 1st stage regulators by connecting quick adapters to Presto-Tap® LDS2000RV installed in 1st & 2nd stage regulator taps accessing 1st stage pressure.
first stage regulator leak testing 0-30# gauge products
part numbers
gauge bleeder (244170)
90° quick adapter (244173)
straight quick adapter (433013)
glycerin filled gauge (433005)
dry gauge (433004)
belt loop holster (433012)
belt Loop Holster (379916)
webb #
first stage regulator leak testing 0-30# gauge products PT30-LP
X
X
X
X
433015
low pressure leak leak testing 0-35# WC gauge products PT-OZ
X
X
N/A
X
X
433016
Presto-Tap® Patented Tank Pressure Fitting Application: Low cost, permanently installed fitting between tank service valve and first stage regulator providing leak test capability without the use of tools. Eliminates the need to discard pigtail to access tank pressure.
tank pressure fitting part #
thread
core
body wrench flat
TPF
1/4” F. NPT
1/4” F. NPT
Up to 90%
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Webb # 260646
9
SECTION
1
Regulator Accessories POL Inlet Fittings
These inlet fittings are available for assembly into either first stage or single stage regulators. All except for 970JR (1/4” hose barb) are machined from brass.
970
970AX
970AW
970HT
970AXS
970S
MFR#
description
Webb#
970 970AX 970AXS 3199W 970AW 970HT 970S 970JR
Hard nose POL with wrench nut. Hard nose POL with wrench nut and excess flow. Soft nose POL with wrench nut and excess flow. Heavy duty hard nose POL with wrench nut and excess flow. Soft nose POL with handwheel. Soft nose POL with handwheel and 60 DMS orifice. Soft nose POL with wrench nut and 60 DMS orifice. Hard nose POL X 1/4” hose barb.
191818 187003 246565 186856 187002 243117 162771 190842
Brackets RegO® Brackets are especially designed for use in installing RegO® Regulators in applications requiring the use of a bracket. MFR#
2503-19
2503-22
2302-31
2302-31 2503-22 2503-19
material Cadium Plated Steel Aluminum
for use with regulator model
Webb#
2302 Series/404B23
162798 162797 162796
LV404 Series, 2503 Series, LV4403 Series
Tee Check Manifolds For use in systems that require uninterrupted gas service during cylinder exchange. Especially for summer cottages, mobile homes and single appliance loads.
1450R 1350R
MFR#
Inlet connections
outlet connection
1350R 1450R
F. POL 1/4” Inverted Flare
M. POL 1/4” M. NPT
Webb#
Marshall PIG#
Webb#
162820 162821
PIG1000A PIG1702A
186519 186552
Multiple Cylinder Manifolds Use with suitable pigtails to connect multiple cylinders together. Ideal for loads that require more than one cylinder to be in service at a time. 1450E 1350E
10
MFR# 1350E 1450E —
Inlet connections
outlet connection
F. POL M. POL 1/4” Inverted Flare 1/4” M. NPT 11/8” HEX L/Check
Gas Equipment Catalog
Webb# 162819 162822 —
Marshall PIG#
Webb#
PIG1701B PIG1702B
186551 186553
victormfg.com
SECTION
1
Regulators Model 046 First Stage Field Regulators description
EQU046-12 EQU06-16 EQU06-20
Body
Webb#
Str
181910 181929 181930
3/4”
High Pressure Regulator First stage with internal relief valve.
1
1” 11/4”
Yellow Spring (04600-021-00) Outlet Pressure 3-10 psi at 75 psi Inlet Pressure Natural Gas (Sp 0.6) Capacity (scfh) Orifice Outlet PRessure PSI 5 10
orifice size Body Size 3/4” 1” 11/4” 3/4” 1” 11/4”
1/8”
3/16”
1/4”
5/16”
3/8”
1/2”
1190 1190 1190 1190 1190 1190
2213 2213 2213 2213 2213 2213
2775 3975 3975 3638 3900 3900
3150 6150 6375 4258 5395 5395
3375 6375 8100 4453 5775 5940
4013 7123 7030 6435 5920 6660
1350 BTU Propane/air mix (Sp 1.20) Capacity (scfh) Orifice Outlet PRessure PSI 5 10
orifice size Body Size 3/4” 1” 11/4” 3/4” 1” 11/4”
1/8”
3/16”
1/4”
5/16”
3/8”
1/2”
845 845 845 845 845 845
1571 1571 1571 1571 1571 1571
1970 2822 2822 2583 2769 2769
2237 4367 4526 3023 3830 3830
2396 4526 5751 3162 4100 4217
2849 5057 4991 4569 4203 4720
propane (sp 1.53) Capacity (btu/hr)* Outlet PRessure PSI 5 10
Body Size 3/4” 1” 11/4” 3/4” 1” 11/4”
orifice size 1/8”
3/16”
1/4”
5/16”
3/8”
1/2”
1,866,000 1,866,000 1,866,000 1,866,000 1,866,000 1,866,000
3,468,272 3,468,272 3,468,272 3,468,272 3,468,272 3,468,272
4,349,024 6,229,952 6,229,952 5,702,496 6,113,016 6,113,016
4,938,680 9,641,000 9,991,808 6,675,304 8,456,712 8,456,712
5,289,488 9,991,808 12,696,264 6,978,840 9,051,344 9,310,096
6,289,664 11,163,656 11,019,352 10,086,352 9,280,240 10,439,648
* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
11
regulators & accessories
MFR#
Pipe Sizes
SECTION
1
Regulators Model 143-80 Second Stage Service Regulators
The 143-80 is designed and built for domestic gas service, as well as for commercial and industrial applications; burners, furnaces, ovens, heaters, gas engines, etc. it can also be used for air, LPG, nitrogen, dry CO2 and other gases. Simple, rugged construction means dependability. Yet, it provides precise pressure control over an amazing range of pressure and load conditions. It is simple to install and adjust. The union nut connection makes it easy to locate the regulator in the best installed position, and servicing is easy and convenient. MFR#
description
143-80-212 143-80-216
Regulator With Internal Relief Valve (IRV)
143-80-220 143-80-2HP
Special High Pressure Outlet Up To 6 psi
Spring Ranges
SIZE
Webb#
3/4” Body
181913
1” Body
181909
11/4” Body
188875
1” Body
247441
Maximum Inlet Pressures
Outlet Pressure ranges
spring color
spring part number
31/2” to 61/2” w.c.
Red
143-62-021-15
181952
5” to 81/2” w.c.
Blue
143-62-021-16
188872
Webb#
6” to 14” w.c.
Green
143-62-021-17
274440
12” w.c. to 1 psi
Orange
143-62-021-18
186673
1/2” psi to 2 psi
Black & White
143-92-021-22
188876
2 psi to 6 psi
Black*
139-16-021-01
—
* Good for use in 143 802HP Series only
orifice sizes
5/8”
1/2”
3/8”
5/16”
1/4”
3/16”
1/8”
Max Inlet Pressure
10 psi
20 psi
40 psi
40 psi
60 psi
125 psi
125 psi
Capacities for Other Gases For capacities (in SCFH) of other gases, multiply the capacity values by a correction factor from the table below: other gases
specific gravity
correction factor
Propane
1.53
0.63
Natural Gas Chart
143-80-2, and 143-80-2HP—Capacity in SCFH Natural Gas (0.6 Specific Gravity, 14.65 psia, 60ºF) Pipe size
3/4” X 3/4”
Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125
orifice size 1/8”
250 310 370 530 860 1200 1500 1800
3/16”
420 560 700 830 1200 1570 1660 1710 1900
1/4”
530 600 700 840 950 1220 1330 1520
5/16”
3/8”
1/2”
5/8”
480 560 620 720 860 970 1240 1340
340 500 570 630 730 880 1000 1250 1450
450 510 580 650 770 900 1020 1270
510 530 600 670 790 900 1020
Pipe size
1” X 1”
Pipe size
11/4” X 11/4”
12
Gas Equipment Catalog
Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125 Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125
orifice size 1/8”
250 310 370 530 860 1200 1540 2100
3/16”
420 580 700 840 1230 1700 1900 2000 2100
1/4”
530 650 890 1140 1360 2000 2000 2000
5/16”
3/8”
1/2”
5/8”
480 700 870 1120 1340 1500 1600 1640
350 550 840 1000 1160 1270 1330 1480 1900
460 600 880 920 950 1140 1200 1400
520 650 780 810 970 1060 1180
orifice size 1/8”
250 310 370 630 860 1200 1550 2250
3/16”
420 580 700 840 1230 1800 2100 2200 2400
1/4”
530 650 890 1140 1360 1600 2200 2400
5/16”
3/8”
1/2”
5/8”
480 700 870 1180 1500 1700 1800 1900
350 550 840 1030 1350 1610 1710 1900 2000
460 680 1020 1200 1490 1580 1800 1900
520 760 1030 1050 1060 1060 1180
victormfg.com
SECTION
1
Regulators Model 143-80 Second Stage Service Regulators (continued)
1
143-80-2, and 143-80-2HP—Capacity in 1000’s of BTU’s of Undiluted Propane (1.5 Specific Gravity, 14.65 psia, 60ºF)
Pipe size
3/4” X 3/4”
Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125
orifice size 1/8”
392 486 580 831 1348 1861 2351 2821
3/16”
658 878 1097 1301 1881 2461 2602 2680 2978
1/4”
831 940 1097 1317 1489 1912 2085 2383
5/16”
3/8”
1/2”
5/8”
752 878 972 1129 1348 1520 1944 2100
533 784 893 987 1144 1379 1567 1959 2273
705 799 909 1019 1207 1411 1599 1991
799 831 940 1050 1238 1411 1599
* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
Pipe size
1” X 1”
Pipe size
11/4” X 11/4”
Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125 Inlet pressure psi 0.5 1 2 3 5 71/2 10 20 40 60 80 125
orifice size 1/8”
392 486 580 831 1348 188 2414 3292
3/16”
658 909 1097 1317 1928 2665 2978 3135 3292
1/4”
831 1019 1395 1787 2132 3135 3135 3135
5/16”
3/8”
1/2”
5/8”
752 1097 1364 1756 2100 2351 2508 2571
549 862 1317 1567 1818 1991 2085 2320 2978
721 940 1379 1442 1489 1787 1881 2194
815 1019 1223 1270 1661 1850
orifice size 1/8”
392 486 580 987 1348 1881 2430 3527
3/16”
658 909 1097 1317 1928 2821 3292 3448 3762
1/4”
831 1019 1395 1787 2132 2508 3448 3762
5/16”
3/8”
1/2”
5/8”
752 1097 1364 1850 2351 2665 2821 2978
549 862 1317 1614 2116 2524 2680 2978 3135
721 1066 1599 1881 2335 2477 2821 2978
815 1191 1614 1646 1661 1661 1850
Victor/F.w. Webb has over 125 outside sales people available to help you. If you need technical expertise, we’ve got it!
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
13
regulators & accessories
Propane Gas Chart*
SECTION
1
Regulators Model 243 Second Stage Service Regulators
These large capacity service regulators are designed and built for commercial, industrial and gas distribution work. They are right at home in such places as factories and foundries, district regulator stations, commercial laundries and laundromats, motels-hotels and apartments, bakeries, restaurants, schools, churches and hospitals. The versatile 243 is used for all kinds of gas fueled equipment. . .boilers, burners, furnaces, ovens, heaters, kilns, engines, air conditioners, etc. Remarkable field versatility results from the union connection between the fully interchangeable bodies and diaphragm-case assemblies. They are easy to install, adjust, inspect and service in all kinds of piping arrangements. While used primarily for natural gas services, Model 243 regulators perform equally well on LPG vapor, air, dry CO2, nitrogen and other inert gas applications. Basic Models MFR#
description
243-12-224 243-12-232
SIZES
12” Diaphram with Internal Relief
243-8-220
181915 181916
11/4” Body
181917
243-8-232 243-8HP-2
Webb#
2” Body -20ºF to 150ºF
11/2” Body
8” Diaphram with Internal Relief
243-8-224
Temperature limit
11/2” Body
Special High Pressure Regulator
181918
2” Body
259165
2” Body
247442
Outlet Pressure Ranges and Springs Spring color
Outlet pressure range 243-12
243-8
spring part#
webb#
Red-Black
—
31/2” to 61/2” w.c.
143-82-021-00
181954
Blue-Black
—
5” to 81/2” w.c.
143-82-021-01
—
Green-Black
—
6” to 14” w.c.
143-82-021-02
—
Red
31/2” to 61/2” w.c.
—
143-16-21-03
188870
Blue
5” to 81/2” w.c.
—
143-16-021-04
—
Green
6” to 14” w.c.
12” to 28” w.c.
143-16-021-05
254467
Orange-Black
10” to 18” w.c.
—
143-16-021-11
—
Orange
12” to 28” w.c.
1 to 2 psi
143-16-021-06
181953
Black
1 to 2 psi
2 to 41/2 psi*
143-16-021-07
181934
Cadium
11/2 to 3 psi
3 to 61/2” psi*
143-16-021-08
188871
Cadium
—
143-16-021-08
—
White
—
6 to 10 psi*
Clamping Plate
143-16-021-13
—
143161020100
308181
* Good for use in 243 8HP Series only
Capacities for Other Gases For capacities ( in SCFH) of other gases, multiply the capacity values by a correction factor from the table below: other gases
specific gravity
correction factor
Propane
1.53
0.63
14
Maximum Inlet Pressure, psig orifice size and Angle Regulator Model And Size 11/4”, 243-12 11/2”, 243-12 2”, 243-12 11/4”, 243-8 11/2”, 243-8 2”, 243-8 11/4”, 243-8HP 11/2”, 243-8HP 2”, 243-8HP
Gas Equipment Catalog
11/4”
11/4”*
1”
1”*
3/4”
3/4”
1/2”
3/8”
1/4”
.207”
30
10
30
10
30
10
10
10
10
10
15 15 15 — — — — — —
25 25 25 — — — — — —
25 25 25 — 25 25 — 25 25
40 40 40 — — — — — —
— — 40 — — 40 — — —
60 60 60 40 40 40 40 40 40
100 100 100 80 80 80 80 80 80
125 125 125 100 100 100 100 100 100
125 125 125 125 125 125 125 125 125
— — — 125 125 — — — —
victormfg.com
SECTION
1
Regulators 243 Variations
1
Internal Relief Valves
Model 243 Capacity Tables Natural Gas Chart
11/2” Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F) orifice size and valve angle pipe size 11/2” Set Point 11” W.C. 2” W.C. Droop Green Spring 6” to 14” W.C. 143-16-021-05
orifice size and valve angle
Inlet pressure (psi)
11/4”
1”
3/4”
1/2”
3/8”
1/4”
30
30
10
10
10
10
1 2 5 10 15 25 40 60 80 100 125
2700 4000 6000 8800 10000
2300 3500 5600 8200 9800 11500
1900 2700 4500 6500 7700 9700 11500 12500
1100 1900 3500 5500 6800 8100 9700 11500 12000 12500
750 1200 2100 2900 3800 5100 7100 9300 10500 11000 11000
400 600 1000 1400 1750 2400 3200 4400 5600 7000 8000
pipe size 11/2” Set Point 1 psi .31 psi Droop Orange Spring 12” to 28” W.C. 143-16-021-06
Inlet pressure (psi)
11/4”
1”
3/4”
1/2”
3/8”
30
30
10
10
10
10
2 5 10 15 25 40 60 80 100 125
6500 8000 9000 12000
5000 7500 8500 11500 13500
4000 6000 8000 10000 11500 13000 15000
2000 4000 5500 7000 9500 11000 13500 15000 16000
1300 2200 3000 4000 5500 7400 10000 13000 14000 14000
500 1000 1400 1800 2400 3300 4500 6000 7000 8500
1/4”
Propane Gas Chart
11/2” Model 243-12-2 Capacity Table in 1000’s of BTU’s or Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
orifice size and valve angle pipe size 11/2” Set Point 11” W.C. 2” W.C. Droop Green Spring 6” to 14” W.C. 143-16-021-05
orifice size and valve angle
Inlet pressure (psi)
11/4” 30
30
10
10
10
10
1 2 5 10 15 25 40 60 80 100 125
4232 6270 9405 13793 15674
3605 5486 8778 12853 15361 18026
2978 4232 7053 10188 12069 15204 18026 19593
1724 2978 5486 8621 10659 12696 15204 18026 18809 19593
1176 1881 3292 4546 5956 7994 11129 14577 16458 17242 17242
627 940 1567 2194 2743 3762 5016 6897 8778 10972 12540
1”
3/4”
1/2”
3/8”
1/4”
pipe size 11/2” Set Point 1 psi .31 psi Droop Orange Spring 12” to 28” W.C. 143-16-021-06
Inlet pressure (psi)
11/4” 30
30
10
10
10
10
2 5 10 15 25 40 60 80 100 125
10188.4 12539.5 14107 18809.3
7837.2 11755.8 13323.2 18025.6 21160.4
6269.76 9404.64 12539.5 15674.4 18025.6 20376.7 23511.6
3134.88 6269.76 8620.92 10972.1 14890.7 17241.8 21160.4 23511.6 25079
2037.67 3448.37 4702.32 6269.76 8620.92 11599.1 15674.4 20376.7 21944.2 21944.2
783.72 1567.44 2194.42 2821.39 3761.86 5172.55 7053.48 9404.64 10972.1 13323.2
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
1”
3/4”
1/2”
3/8”
1/4”
15
regulators & accessories
The 243 is available with an internal relief valve (IRV). It’s a built-in safety device for providing a limited level of over-pressure protection. Like any relief valve, an IRV must be carefully sized. Internal relief valves are not available in the high pressure Model 243-8HP.
SECTION
1
Regulators Model 243 Capacity Tables
(continued)
Natural Gas Chart
11/2” Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F) orifice size and valve angle pipe size 11/2” Set Point 1 psi .2 psi Droop Black Spring 1 to 2 psi 143-16-021-07
orifice size and valve angle
Inlet pressure (psi)
11/4”
1”
3/4”
1/2”
3/8”
1/4”
30
30
10
10
10
10
2 5 10 15 25 40 60 80 100 125
2800 5500 8000 10000
2450 5100 7500 9100 11000
1500 3700 5700 7100 9300 11000 12500
1200 2400 4000 5300 7300 9300 11000 12500 13000
850 1600 2700 3700 5100 7100 9300 10500 11000 11000
500 950 1400 1750 2400 3200 4600 5600 7000 8000
pipe size 11/2” Set Point 2 psi .6 psi Droop Cadium Spring 11/2 to 3 psi 143-16-021-08
Inlet pressure (psi)
11/4”
1”
3/4”
1/2”
3/8”
30
30
10
10
10
10
5 10 15 25 40 60 80 100 125
6000 10000 13000
5300 9300 12000 14500
4100 7100 8800 11000 13500 15000
2700 4700 6200 8600 11000 13500 15000 16000
1700 2900 3800 5200 7100 10000 12000 12000 12000
900 1400 1700 2400 3200 4600 5600 7000 8000
1/4”
Propane Gas Chart
11/2” Model 243-12-2 Capacity Table in 1000’s of BTU’s or Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
orifice size and valve angle pipe size 11/2” Set Point 1 psi .2 psi Droop Black Spring 1 to 2 psi 143-16-021-07
orifice size and valve angle
Inlet pressure (psi)
11/4” 30
30
10
10
10
10
2 5 10 15 25 40 60 80 100 125
4389 8621 12540 15674
3840 7994 11756 14264 17242
2351 5800 8934 11129 14577 17242 19593
1881 3762 6270 8307 11442 14577 17242 19593 20377
1332 2508 4232 5800 7994 11129 14577 16458 17242 17242
784 1489 2194 2743 3762 5016 7210 8778 10972 12540
1”
3/4”
1/2”
3/8”
1/4”
pipe size 11/2” Set Point 2 psi .6 psi Droop Cadium Spring 11/2 to 3 psi 143-16-021-08
Inlet pressure (psi)
11/4” 30
30
10
10
10
10
5 10 15 25 40 60 80 100 125
9405 15674 20377
8307 14577 18809 22728
6427 11129 13793 17242 21160 23512
4232 7367 9718 13480 17242 21160 23512 25079
2665 4546 5956 8151 11129 15674 18809 18809 18809
1411 2194 2665 3762 5016 7210 8778 10972 12540
1”
3/4”
1/2”
3/8”
1/4”
Victor/F.w. Webb can provide customized training for your company! Just ask your victor sales person.
16
Gas Equipment Catalog
victormfg.com
SECTION
1
Regulators Model 243 Capacity Tables
(continued)
1
Natural Gas Chart
orifice size and valve angle pipe size 2” Set Point 11” W.C. 2” W.C. Droop Green Spring 6” to 14” W.C. 143-16-021-05
orifice size and valve angle
Inlet pressure (psi)
11/4”
1”
3/4”
3/4”
1/2”
3/8”
1/4”
30
30
30
10
10
10
10
1 2 5 10 15 25 40 60 80 100 125
3400 5600 10500 13000 14000
3000 4700 9000 13000 14000 15000
2100 3700 7800 12000 15000 20000 20000
1950 3400 6900 9200 10500 12000 14500 15500
1150 2000 3500 5500 7000 500 12500 13000 14000 14000
750 1200 2100 3200 4000 5300 7500 10000 12000 12000 12000
400 600 1000 1600 1800 2400 3200 4400 5600 7000 8000
pipe size 2” Set Point 1 psi .31 psi Droop Orange Spring 12” to 28” W.C. 143-16-021-06
Inlet pressure (psi)
11/4”
1”
3/4”
3/4”
1/2”
3/8”
30
30
30
10
10
10
10
2 5 10 15 25 40 60 80 100 125
6500 8000 9000 12000
5000 7500 8500 11000 13500
4000 6000 8000 10000 12500 14000
4000 6000 8000 10000 11500 13000 15000
2000 4000 5500 7000 9500 11000 13500 15000 16000
1300 2200 3000 4000 5500 7400 10000 13000 14000 14000
500 1000 1400 1800 2400 3300 4500 6000 7000 8500
1/4”
Propane Gas Chart
2” Model 243-12-2 Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
orifice size and valve angle pipe size 2” Set Point 11” W.C. 2” W.C. Droop Green Spring 6” to 14” W.C. 143-16-021-05
orifice size and valve angle
Inlet pressure (psi)
11/4”
1”
3/4”
3/4”
1/2”
3/8”
1/4”
30
30
30
10
10
10
10
1 2 5 10 15 25 40 60 80 100 125
5329 8778 16458 20377 21944
4702 7367 14107 20377 21944 23512
3292 5800 12226 18809 23512 31349 31349
3057 5329 10815 14420 16458 18809 22728 24295
1803 3135 5486 8621 10972 784 19593 20377 21944 21944
1176 1881 3292 5016 6270 8307 11756 15674 18809 18809 18809
627 940 1567 2508 2821 3762 5016 6897 8778 10972 12540
pipe size 2” Set Point 1 psi .31 psi Droop Orange Spring 12” to 28” W.C. 143-16-021-06
Inlet pressure (psi)
11/4”
1”
3/4”
3/4”
1/2”
3/8”
30
30
30
10
10
10
10
2 5 10 15 25 40 60 80 100 125
10188 12540 14107 18809
7837 11756 13323 17242 21160
6270 9405 12540 15674 19593 21944
6270 9405 12540 15674 18026 20377 23512
3135 6270 8621 10972 14891 17242 21160 23512 25079
2038 3448 4702 6270 8621 11599 15674 20377 21944 21944
784 1567 2194 2821 3762 5173 7053 9405 10972 13323
1/4”
Victor/F.w. Webb can help you layout a petite 7 base board system.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
17
regulators & accessories
2” Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)
SECTION
1
Regulators Model 243 Capacity Tables
(continued)
Natural Gas Chart
11/4” Model 243-8-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F) orifice size and valve angle pipe size 11/4” Set Point 11” wc. 2” wc Droop Green Spring 6” to 14” wc 143-82-021-02
Inlet pressure (psi)
3/4”
10
10
1 2 5 10 15 25 40 60 80 100 125
1150 1850 2500 2900 3700 4250 5300
1000 1350 2200 2700 2950 4000 4200 4850 5850
1/2”
3/8”
1/4”
0.207”
10
10
10
650 1000 1750 2450 2600 3300 3800 4400 5600 6000
300 450 800 1300 1700 2400 3200 4400 5600 7000 8000
350 550 900 1100 1500 2100 2900 3700 4500 5600
orifice size and valve angle pipe size
11/4” Set Point 1” psi Droop Orange Spring 1 to 2 psi 143-16-021-06
Inlet pressure (psi)
3/4”
10
10
2 5 10 15 25 40 60 80 100 125
1850 2100 2700 3150 4150 5300
1150 1700 2000 3100 3250 3800 4600 4650
1/2”
3/8”
1/4”
0.207”
10
10
10
850 1350 1950 2050 2850 3600 4250 5600 6000
450 750 1300 1700 2400 3200 4400 5600 7000 8000
500 800 1000 1500 2100 2900 3700 4500 5600
Propane Gas Chart
11/4” Model 243-8-2 Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
orifice size and valve angle pipe size 11/4” Set Point 11” wc. 2” wc Droop Green Spring 6” to 14” wc 143-82-021-02
18
Inlet pressure (psi)
3/4”
1/2”
3/8”
1/4”
0.207”
10
10
10
10
10
1 2 5 10 15 25 40 60 80 100 125
1803 2900 3919 4546 5800 6662 8307
1567 2116 3448 4232 4624 6270 6583 7602 9170
1019 1567 2743 3840 4075 5173 5956 6897 8778 9405
470 705 1254 2038 2665 3762 5016 6897 8778 10972 12540
549 862 1411 1724 2351 3292 4546 5800 7053 8778
Gas Equipment Catalog
orifice size and valve angle pipe size
11/4” Set Point 1” psi Droop Orange Spring 1 to 2 psi 143-16-021-06
Inlet pressure (psi)
3/4”
1/2”
3/8”
1/4”
0.207”
10
10
10
10
10
2 5 10 15 25 40 60 80 100 125
2900 3292 4232 4937 6505 8307
1803 2665 3135 4859 5094 5956 7210 7289
1332 2116 3057 3213 4467 5643 6662 8778 9405
705 1176 2038 2665 3762 5016 6897 8778 10972 12540
784 1254 1567 2351 3292 4546 5800 7053 8778
victormfg.com
SECTION
1
Regulators Model 243 Capacity Tables
(continued)
1
Natural Gas Chart
orifice size and valve angle pipe size 2” Set Point 1 psi .2 psi Droop Black Spring 1 to 2 psi 143-16-021-07
orifice size and valve angle
Inlet pressure (psi)
11/4”
1”
3/4”
3/4”
1/2”
3/8”
1/4”
30
30
30
10
10
10
10
2 5 10 15 25 40 60 80 100 125
3350 6600 11000 13000
3000 5900 10000 12000 15000
2000 4200 7600 9300 16500 20000
1900 3900 6500 8300 11000 14000 15500
1200 2400 4100 5600 8500 12500 13000 14000 14000
1000 1600 2800 3800 5300 7500 10000 12000 12000 12000
500 1000 1450 1700 2400 3400 4400 5600 7000 8000
pipe size 2” Set Point 2 psi .6 psi Droop Cadium Spring 11/2 to 3 psi 143-16-021-08
Inlet pressure (psi)
11/4”
1”
3/4”
3/4”
1/2”
3/8”
30
30
30
10
10
10
10
5 10 15 25 40 60 80 100 125
8200 12500 15500
7400 11300 14500 18000
5200 8700 11500 16500 20000
4800 7800 10000 13500 16500 16500
2900 4800 6500 9000 12500 15500 16000 16000
1900 3000 3800 5300 7600 10000 12000 12000 12000
900 1400 1700 2400 3400 4600 5600 7000 8000
1/4”
Propane Gas Chart
2” Model 243-12-2 Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
orifice size and valve angle pipe size 2” Set Point 1 psi .2 psi Droop Black Spring 1 to 2 psi 143-16-021-07
orifice size and valve angle
Inlet pressure (psi)
11/4”
1”
3/4”
3/4”
1/2”
3/8”
1/4”
30
30
30
10
10
10
10
pipe size
2 5 10 15 25 40 60 80 100 125
5251 10345 17242 20377
4702 9248 15674 18809 23512
3135 6583 11913 14577 25863 31349
2978 6113 10188 13010 17242 21944 24295
1881 3762 6427 8778 13323 19593 20377 21944 21944
1567 2508 4389 5956 8307 11756 15674 18809 18809 18809
784 1567 2273 2665 3762 5329 6897 8778 10972 12540
2” Set Point 2 psi .6 psi Droop Cadium Spring 11/2 to 3 psi 143-16-021-08
Inlet pressure (psi)
11/4”
1”
3/4”
3/4”
1/2”
3/8”
30
30
30
10
10
10
10
5 10 15 25 40 60 80 100 125
12853 19593 24295
11599 17712 22728 28214
8151 13637 18026 25863 31349
7524 12226 15674 21160 25863 25863
4546 7524 10188 14107 19593 24295 25079 25079
2978 4702 5956 8307 11913 15674 18809 18809 18809
1411 2194 2665 3762 5329 7210 8778 10972 12540
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
1/4”
19
regulators & accessories
2” Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)
SECTION
1
Regulators Model 243 Capacity Tables
(continued)
Natural Gas Chart
2” and 11/2” Model 243-8-2 Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F) orifice size and valve angle pipe size
2” and 11/2” Set Point 11” w.c. 2” w.c. Droop Green Spring 6” to 14” w.c. 143-82-021-02
Inlet pressure (psi) 1 2 5 10 15 25 40 60 80 100 125
orifice size and valve angle
1”
3/4”
1/2”
3/8”
1/4”
0.207
30
10
10
10
10
10
1650 2700 4800 7000 9000 11000
1150 2000 3800 5400 7400 8800 11000
1000 1400 2600 4200 5500 7500 9600 11000 11500
650 1000 1750 2800 3600 5100 7100 9300 10500 11000
300 450 900 1300 1700 2400 3200 4400 5600 7000 8000
350 600 900 1100 1500 2100 2900 3700 4500 5600
pipe size
11/2” Set Point 2 psi .2 Droop Orange Spring 1 to 2 psi 143-16-021-06
Inlet pressure (psi) 2 5 10 15 25 40 60 80 100 125
1”
3/4”
1/2”
3/8”
1/4”
0.207
30
10
10
10
10
10
2100 4000 6500 8400 11000
1650 3200 5200 6500 11000
1200 2100 3100 4400 6500 8600 10500 11500
850 1300 2200 3000 4400 6700 9000 10500 11000
450 850 1300 1700 2400 3200 4400 5600 7000 8000
550 800 1000 1500 2100 2900 3700 4500 5600
orifice size and valve angle pipe size
2” Set Point 2 psi .2 Droop Orange Spring 1 to 2 psi 143-16-021-06
Inlet pressure (psi) 2 5 10 15 25 40 60 80 100 125
1”
3/4”
1/2”
3/8”
1/4”
30
10
10
10
10
10
2400 4000 7000 11000 14500
1800 3400 6000 9000 15000 17500
1700 3300 5400 7000 10000 12000
1200 2200 3500 4600 7400 10500 11000
850 1300 2200 3100 4800 7000 9500 10500 11000
450 900 1400 1700 2400 3400 4600 5600 7000 8000
0.207
Propane Gas Chart*
2” and 11/2” Model 243-8-2 Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
orifice size and valve angle pipe size
2” and 11/2” Set Point 11” w.c. 2” w.c. Droop Green Spring 6” to 14” w.c. 143-82-021-02
Inlet pressure (psi) 1 2 5 10 15 25 40 60 80 100 125
1”
3/4”
1/2”
3/8”
orifice size and valve angle
1/4”
0.207 10
30
10
10
10
10
2586 4232 7524 10972 14107 17242
1803 3135 5956 8464 11599 13793 17242
1567 2194 4075 6583 8621 11756 15047 17242 18026
1019 1567 2743 4389 5643 7994 11129 14577 16458 17242
470 705 1411 2038 2665 3762 5016 6897 8778 10972 12540
549 940 1411 1724 2351 3292 4546 5800 7053 8778
pipe size
11/2” Set Point 2 psi .2 Droop Orange Spring 1 to 2 psi 143-16-021-06
2” Set Point 2 psi .2 Droop Orange Spring 1 to 2 psi 143-16-021-06
20
Gas Equipment Catalog
2 5 10 15 25 40 60 80 100 125
1”
3/4”
1/2”
3/8”
1/4”
0.207
30
10
10
10
10
10
3292 6270 10188 13166 17242
2586 5016 8151 10188 13480 17242
1881 3292 4859 6897 10188 13480 16458 18026
1332 2038 3448 4702 6897 10502 14107 16458 17242
705 1332 2038 2665 3762 5016 6897 8778 10972 12540
862 1254 1567 2351 3292 4546 5800 7053 8778
orifice size and valve angle pipe size
* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
Inlet pressure (psi)
Inlet pressure (psi) 2 5 10 15 25 40 60 80 100 125
1”
3/4”
1/2”
3/8”
1/4”
30
10
10
10
10
10
3762 6270 10970 17242 22728
2821 5329 9405 14107 23512 27430
2665 5173 8484 10972 15674 18809
1881 3448 5486 7210 11599 16458 19593 21160
1332 2038 3448 4859 7524 10972 14891 16458 17242
705 1411 2194 2665 3762 5329 7210 8778 10972 1250
0.207
victormfg.com
SECTION
1
Regulators Model 243 High Pressure Capacity Tables
Natural Gas Chart
(0.6 Specific Gravity — 14.65 psia — 60°F)
orifice size and valve angle
*
pipe size 11/4”
Set Point 5 psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08
Inlet pressure (psi)
3/4”
1/2”
3/8”
1/4”
10
10
10
10
10 15 25 40 60 80 100 125
3300 3400 4400 5800
2050 3100 3650 3800 4400 4500
2000 2200 3050 3200 4100 5300 6000
1300 1700 2400 3200 4400 5600 7000 8000
orifice size and valve angle
*
pipe size 11/2”
Set Point 5 psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08
Inlet pressure (psi) 10 15 25 40 60 80 100 125
1”
3/4”
1/2”
3/8”
30
10
10
10
10
6000 8600 12000
5500 6500 9300 12000
3200 4400 6100 8500 10000 11000
2300 3200 4800 6100 8700 10000 11000
1300 1700 2400 3200 4400 5600 7000 8000
1/4”
orifice size and valve angle pipe size 2” Set Point 5 psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08
Inlet pressure (psi) 10 15 25 40 60 80 100 125
1”
3/4”
1/2”
3/8”
30
10
10
10
10
6000 8600 13000
5500 6500 8200 12000
3200 4400 6100 8700 10000 11500
2400 3200 4800 6100 8700 10000 11000
1300 1700 2400 3400 4600 5600 7000 8000
1/4”
Propane Gas Chart**
11/4”, 11/2”, 2” Models 243-8HP Capacity Table in 1000’s of BTU’s Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
orifice size and valve angle
*
pipe size 11/4”
Set Point 5 psi 1 psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08
Inlet pressure (psi)
3/4”
10
10
10
10
10 15 25 40 60 80 100 125
5173 5329 6897 9091
3213 4859 5721 5956 6897 7053
3135 3448 4781 5016 6427 8307 9405
2038 2665 3762 5016 6897 8778 10972 12540
1/2”
3/8”
orifice size and valve angle
1/4”
*
pipe size 11/2”
Set Point 5 psi 1 psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08
Inlet pressure (psi) 10 15 25 40 60 80 100 125
1”
3/4”
1/2”
3/8”
1/4”
30
10
10
10
10
9405 13480 18809
8621 10188 14577 18809
5016 6897 9561 13323 15674 17242
3605 5016 7524 9561 13637 15674 17242
2038 2665 3762 5016 6897 8778 10972 12540
orifice size and valve angle pipe size 2” Set Point 5 psi 1psi Droop Cadium Spring 3 to 61/2 psi 143-16-021-08
Inlet pressure (psi) 10 15 25 40 60 80 100 125
1”
3/4”
1/2”
3/8”
30
10
10
10
10
9405 13480 20377
8621 9405 12853 18809
5016 6897 9561 13637 15674 17242
3762 5016 7524 9561 13637 15674 17242
2038 2665 3762 5329 7210 8778 10972 12540
1/4”
* Special Order ** Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
21
regulators & accessories
11/4”, 11/2”, 2” Models 243-8HP Capacity Table in SCFH of Natural Gas
1
SECTION
1
Regulators Gas Appliance Pressure Regulators
Maxitrol Company manufactures a complete line of gas appliance regulators for domestic, commercial, and industrial needs.
Balance Valve Design — 210D, E & G Main burner and pilot applications. The balanced valve 210 Series are designed for use with intermediate pressure. The balancing diaphragm virtually eliminates inlet pressure effect, which makes them ideal for applications where supply pressure fluctuates.
210D, E & G
MFR#
pipe sizes
capacities to
210D 210E 210G
1”, 11/4”, 11/2”, 2”, 21/2”, & 3”
6500 CFH 12000 CFH 26000 CFH
inlet pressures to
outlet pressures
10 psi (700 mbar)
1.0” to 42” w.c. (2.5 to 105 mbar)
MFR#
body sizes
Qty. per case
webb#
210D-1
1”
4
201676
210D-1010-114
11/4”
4
201679
210D-112
11/2”
4
201678
210D-36-24
11/2”
4
199526
210D412-24
11/2”
4
—
2”
2
198116
210E412-24
11/2”
2
201673
210E412-32
2”
2
201674
210E-2
Natural Gas Chart
11/2” & 2” Stock Spring Violet 4-12” w.c. Model 210E Capacity Table in SCFH of Natural Gas (0.6 Specific Gravity — 14.65 psia — 60°F)
22
Pipe size
Inlet pressure (psi)
Set point 2” w.c.
Set point 4” w.c.
Set point 6” w.c.
Set point 9” w.c.
Set point 12” w.c.
Set point 16” w.c.
11/2”
8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi
4450 6300 7000 7000 7000 7000 7000 7000 7000 7000
3650 5750 7500 8800 8800 8800 8800 8800 8800 8800
2550 5150 7050 8500 8500 8500 8500 8500 8500 8500
4050 6300 7950 10450 10500 10500 10500 10500 10500
5450 7250 9950 10500 10500 10500 10500 10500
4050 6300 9250 10500 10500 10500 10500 10500
Pipe size
Inlet pressure (psi)
Set point 2” w.c.
Set point 4” w.c.
Set point 6” w.c.
Set point 9” w.c.
Set point 12” w.c.
Set point 16” w.c.
2”
8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi
5150 7250 8000 8000 8000 8000 8000 8000 8000 8000
4200 6650 8650 10000 10000 10000 10000 10000 10000 10000
2950 5950 8150 9850 10000 10000 10000 10000 10000 10000
4700 7250 9150 12000 12000 12000 12000 12000 12000
6300 8400 11500 12000 12000 12000 12000 12000
4700 7250 10700 12000 12000 12000 12000 12000
Gas Equipment Catalog
victormfg.com
SECTION
1
Regulators Gas Appliance Pressure Regulators
(continued)
Propane Gas Chart*
(1.5 Specific Gravity — 14.65 psia — 60°F) Pipe size
Inlet pressure (psi)
Set point 2” w.c.
Set point 4” w.c.
Set point 6” w.c.
Set point 9” w.c.
Set point 12” w.c.
Set point 16” w.c.
11/2”
8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi
6975 9875 10972 10972 10972 10972 10972 10972 10972 10972
5721 9013 11756 13793 13793 13793 13793 13793 13793 13793
3997 8072 11050 13323 13793 13793 13793 13793 13793 13793
6348 9875 12461 16380 16458 16458 16458 16458 16458
8543 11364 15596 16458 16458 16458 16458 16458
6348 9875 14499 16458 16458 16458 16458 16458
Pipe size
Inlet pressure (psi)
Set point 2” w.c.
Set point 4” w.c.
Set point 6” w.c.
Set point 9” w.c.
Set point 12” w.c.
Set point 16” w.c.
8” w.c. 8072 6583 4624 .5 psi 11364 10423 9326 7367 .75 psi 12540 13558 12775 11364 9875 1 psi 12540 15674 15439 1432 13166 1.5 psi 12540 15674 15674 18809 18026 2” 2 psi 12540 15674 15674 18809 18809 3 psi 12540 15674 15674 18809 18809 5 psi 12540 15674 15674 18809 18809 7.5 psi 12540 15674 15674 18809 18809 10 psi 12540 15674 15674 18809 18809 * Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
7367 11364 16772 18809 18809 18809 18809 18809
Natural Gas Chart
1” & 11/4” Stock Spring Violet 4-12” w.c. Model 210D Capacity Table in SCFH of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) Pipe size
Inlet pressure (psi)
Set point 2” w.c.
Set point 4” w.c.
Set point 6” w.c.
Set point 9” w.c.
Set point 12” w.c.
Set point 16” w.c.
1”
8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi
2400 3400 3500 3500 3500 3500 3500 3500 3500 3500
1900 3100 4000 4000 4000 4000 4000 4000 4000 4000
1300 2700 3800 4500 4500 4500 4500 4500 4500 4500
2200 3400 4300 4800 4800 4800 4800 4800 4800
2900 3900 4800 4800 4800 4800 4800 4800
2200 3400 5000 5000 5000 5000 5000 5000
Pipe size
Inlet pressure (psi)
Set point 2” w.c.
Set point 4” w.c.
Set point 6” w.c.
Set point 9” w.c.
Set point 12” w.c.
Set point 16” w.c.
11/4”
8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi
3000 4000 4000 4000 4000 4000 4000 4000 4000 4000
2400 3905 5000 5000 5000 5000 5000 5000 5000 5000
1700 3400 4700 5000 5000 5000 5000 5000 5000 5000
2700 4200 5300 6000 6000 6000 6000 6000 6000
3700 4900 6000 6000 6000 6000 6000 6000
2700 4200 6000 6000 6000 6000 6000 6000
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
23
1 regulators & accessories
11/2” and 2” Stock Spring Violet 4-12” w.c. Model 120E Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas
SECTION
1
Regulators Gas Appliance Pressure Regulators
(continued)
Natural Gas Chart
11/2” Stock Spring Violet 4-12” w.c. Model 210D Capacity Table in SCFH of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) Pipe size
Inlet pressure (psi)
Set point 2” w.c.
Set point 4” w.c.
Set point 6” w.c.
Set point 9” w.c.
Set point 12” w.c.
Set point 16” w.c.
11/2”
8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi
3100 4000 4000 4000 4000 4000 4000 4000 4000 4000
2500 4000 5000 5000 5000 5000 5000 5000 5000 5000
1800 3600 5000 5000 5000 5000 5000 5000 5000 5000
2800 4400 5600 6000 6000 6000 6000 6000 6000
3800 5100 6000 6000 6000 6000 6000 6000
2800 4400 6500 6500 6500 6500 6500 6500
Propane Gas Chart*
1”, 11/4” and 11/2” Stock Spring Violet 4-12” w.c. Model 210D Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F) Pipe size
Inlet pressure (psi)
Set point 2” w.c.
Set point 4” w.c.
Set point 6” w.c.
Set point 9” w.c.
Set point 12” w.c.
Set point 16” w.c.
1”
8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi
3762 5329 5486 5486 5486 5486 5486 5486 5486 5486
2978 4859 6270 6270 6270 6270 6270 6270 6270 6270
2038 4232 5956 7053 7053 7053 7053 7053 7053 7053
3448 5329 6740 7524 7524 7524 7524 7524 7524
4546 6113 7524 7524 7524 7524 7524 7524
3448 5329 7837 7837 7837 7837 7837 7837
Pipe size
Inlet pressure (psi)
Set point 2” w.c.
Set point 4” w.c.
Set point 6” w.c.
Set point 9” w.c.
Set point 12” w.c.
Set point 16” w.c.
11/4”
8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi
4702 6270 6270 6270 6270 6270 6270 6270 6270 6270
3762 6121 7837 7837 7837 7837 7837 7837 7837 7837
2665 5329 7837 7837 7837 7837 7837 7837 7837 7837
4232 6583 8307 9405 9405 9405 9405 9405 9405
5800 7080 9405 9405 9405 9405 9405 9405
4232 6583 9405 9405 9405 9405 9405 9405
Pipe size
Inlet pressure (psi)
Set point 2” w.c.
Set point 4” w.c.
Set point 6” w.c.
Set point 9” w.c.
Set point 12” w.c.
Set point 16” w.c.
11/2”
8” w.c. .5 psi .75 psi 1 psi 1.5 psi 2 psi 3 psi 5 psi 7.5 psi 10 psi
4869 6270 6270 6270 6270 6270 6270 6270 6270 6270
3919 6270 7837 7837 7837 7837 7837 7837 7837 7837
2821 5643 7837 7837 7837 7837 7837 7837 7837 7837
4389 6897 8778 9405 9405 9405 9405 9405 9405
5956 7994 9405 9405 9405 9405 9405 9405
4389 6897 10188 10188 10188 10188 10188 10188
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
24
Gas Equipment Catalog
victormfg.com
SECTION
1
Regulators Straight-Thru-Flow-Design RV52, RV53, RV61, RV81, RV91, RV111, RV131 1/2”, 3/4”, 11/4”, 11/2”, 2”, 21/2”, 3”, & 4” Main burner only
1
RV52 & RV53
RV61
RV81 & RV91
MFR#
pipe sizes
capacities to
RV52 RV53 RV61 RV81 RV91 RV111 RV131
1/2” & 3/4”
900 CFH 130 CFH 2500 CFH 4500 CFH 7500 CFH 1 psi 2 psi
3/4” & 1”
1” & 11/4” 11/4”, 11/2”, 2” & 21/2” 21/2” & 3” 4” Flanged
MFR#
RV111
RV131
outlet pressures
1/2 psi (35 mbar)
1.0” to 12” w.c.
1 psi (70 mbr)
1.0” to 22” w.c.
2 psi (140 mbr)
3.0” to 42” w.c.
body sizes
Qty. per case
webb#
RV52-12
1/2”
25
108537
RV52-34
3/4”
25
196920
RV53-1
1”
25
118670
RV53-34
3/4”
25
108742
RV61-1
Natural Gas Chart
inlet pressures to
1”
18
185908
RV61-114
11/4”
18
188934
RV81-114
11/4”
4
196848
2”
4
109623
RV91-2
Straight thru flow RV regulator (Appliance or combustion regulators) Capacity Table in CFH’s of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) MFR#
Pipe size
rv52 rv53 rv61 rv81 rv91 rv111 rv131
1/2” or 3/4”
3/4” or 1” 1” or 11/4” 11/4” or 11/2” 2” or 21/2” 21/2” or 3” 4”
Pressure drop in w.c.
CSA Max
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
2
3
4
450 710 1100 2500 3275 7500 —
151 217 379 780 1212 2742 4734
214 306 536 1102 1714 3878 6695
362 375 675 1350 2100 4750 8200
302 433 759 1559 2424 5485 9468
338 484 848 1743 2711 6718 11596
370 530 929 1909 2969 6718 11596
400 573 1004 2062 3208 7256 12390
427 612 1073 2204 3429 7757 13390
453 650 1138 2339 3637 8227 13390
478 684 1200 2465 3834 8572 14971
676 968 1742 3465 5422 14134 21172
828 1185 2134 4269 6640 14862 25930
956 1369 2464 4929 7668 17161 29942
Propane Gas Chart*
Straight thru flow RV regulator (Appliance or combustion regulators) Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F) MFR#
Pipe size
CSA Max
Pressure drop in w.c. 0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1/2” or 3/4” 705 237 335 411 473 530 580 627 669 710 749 rv52 rv53 3/4” or 1” 1113 340 480 588 679 759 831 898 959 1019 1072 rv61 1” or 11/4” 1724 594 840 1058 1190 1329 1456 1574 1682 1784 1881 rv81 11/4” or 11/2” 3919 1223 1727 2116 2444 2732 2992 3232 3455 3666 3864 rv91 2” or 21/2” 5133 1900 2687 3292 3799 4249 4654 5028 5375 5701 6010 rv111 21/2” or 3” 11756 4298 6079 7445 8597 9612 10530 11373 12159 12895 13436 rv131 4” — 7420 10494 12853 14841 16593 18176 19632 20988 22261 23466 * Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
2
3
4
1060 1517 2730 5463 8499 22154 33186
1298 1857 3345 6691 10408 23295 40644
1498 2146 3862 7726 12019 26899 46932
25
regulators & accessories
The straight-thru-flow RV Series, size for size, has the highest pressure drop capacity of any regulator design available. They are best used when supply pressure is low enough to cause concern about capacity. Gases: Natural, manufactured, mixed, liquified petroleum, or LP gas-air mixture. Features: • Greater accuracy — higher pressure drop capacity. • Outlet pressure available to 42” w.c. • Available in full range of pipe sizes from 1/2” to 4”. • All models tapped with NPT vent bosses. • A.G.A. Rated (except RV131) — 1/2 psi (35 mbar).
SECTION
1
Regulators 325 Series L-Model Line Regulators & OPDs, #2 Inlet Regulators
Features: • CSA certified for up to 5-psi inlet pressure. • Over-pressure protection device (OPD) to limit downstream pressure in case of regulator failure. • Maxitrol OPD approved and tested with the regulator. • Regulators or OPD’s can be ordered as separate items — or as a factory assembled unit. • Self-aligning valve with lever action for dead end regulator lockup. • Optional vent limiter eliminates the need to run vent piping to an outside area. Benefits: • Meets new ANSI standard Z21-80 for line pressure regulators — for use on piping systems such as CSST or semi-rigid copper tubing up to 5-psi. • OPD provides required downstream over-pressure protection for supply pressures in excess of 2-psi. • Pounds to inches regulator provides precise control from pilot flows to full regulator capacity. • Meets many utility specifications.
325-5ALX Outlet Pressure Range (all models) Certified spring – 7-11 in w.c.
7” WC Less Vent Limiter
Attention: To comply with
body sizes
Qty. per case
webb#
325-3L-12
1/2”
50
252139
325-3L-38
3/8”
50
252138
325-5AL-1
1”
18
252142
325-5AL-12
1/2”
18
252140
325-5AL-34
3/4”
18
252141
325-7AL-114
11/4”
4
224151
325-7AL-112
11/2”
4
224152
MFR#
the ANSI Z21-80 Standard for Line Pressure Regulators, installations exceeding 2-psi nominal require a tested and approved over-pressure protection device (OPD) for use with the regulator. (Over-pressure protection is not required for supply pressures up to and including 2-psi.)
11” WC With Vent Limiter MFR#
Description
MXT325-3L-38LP MXT325-3L-12LP MXT325-5AL-12LP MXT325-5AL-34LP MXT325-5AL-1LP MXT325-7AL-114LP
Accessories Vent Limiting Means
Special Order For 325 Series With OPD
MXT325-7AL-112LP
webb#
LP REG 3/8" IPS AT 11"WC W/ VNT LIMITER LP REG 1/2" IPS AT 11"WC W/ VNT LIMITER
432833 432832
LP REG 1/2" IPS AT 11"WC W/VNT LIMITER
LP REG 3/4" IPS AT 11"WC W/ VNT LIMITER LP REG 1" IPS AT 11"WC W/ VNT LIMITER
432834 432836 432835
LP REG 1-1/4" IPS AT 11"WC W/VNT LIMITER LP REG 1-1/2" IPS AT 11"WC W/VNT LIMITER
432838 432837
Ball check permits free inhalation for fast regulator diaphragm response on opening cycle, but limits gas escapement to within ANSI standards should a diaphragm rupture. MFR#
Description
12A04
Optional Automatic Vent Limiting Device for RV48, RV52, RV53, RV61
77527
12A06
192793
12A49
Optional Vent Limiting Orifice for RV48, RV52, RV53, RV61 Optional Automatic Vent Limiting Device for 325-3, 325-3L, 325-3LX, OPD48, OPD600, 325-3L47 (reg. only), 325-3L48 (reg. & OPD), 325-5AL48 (OPD only), 325-5AL600 (OPD only) Optional Automatic Vent Limiting Device for 325-5A, 325-5AL, 325-ALX, 325-5AL48 (reg. only), 325-5AL600 (reg. only) Optional Automatic Vent Limiting Device for 325-7L, 325-7AL
13A15
Outdoor Vent Protector for 3L and 5AL
246350
13A25
Outdoor Vent Protector for 3L and 5AL
433028
12A09 12A39
Vent Limiter 12A09
webb#
109780 192794 436746
Natural Gas Chart
Model 325L Series 2 PSI Max Inlet Capacity Table in SCFH of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) MFR# 325-3L
Pipe size 3/8” or 1/2”
325-5AL
1/2”
325-5AL
3/4” or 1”
325-7AL
11/4” or 11/2”
26
outlet pressure
1/2 PSI
3/4 PSI
Inlet
1 PSI Inlet
11/2 PSI Inlet
2 PSI Inlet
Max Load Multiple appliances
max individual appliance load
7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c.
145 110 335 250 335 250 690 520
200 180 425 420 475 420 970 860
250 230 425 425 550 535 1000 1000
250 250 425 425 550 550 1000 1000
250 250 425 425 550 550 1000 1000
250 250 425 425 550 550 1000 1000
140 140 300 300 300 300 900 900
Inlet
Gas Equipment Catalog
victormfg.com
SECTION
1
Regulators 325 Series L-Model Line Regulators & OPDs, #2 Inlet Regulators
1
Propane Gas Chart*
Model 325L Series 2 PSI Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas
MFR# 325-3l
Pipe size 3/8” or 1/2”
325-5al
1/2”
325-5al
3/4” or 1”
325-7l
11/4” or 11/2”
outlet pressure
1/2 PSI
3/4 PSI
Inlet
1 PSI Inlet
11/2 PSI Inlet
2 PSI Inlet
Max Load Multiple appliances
max individual appliance load
7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c.
227 172 525 392 525 392 1082 815
313 282 666 658 745 658 1520 1348
392 361 666 666 862 839 1567 1567
392 392 666 666 862 862 1567 1567
392 392 666 666 862 862 1567 1567
392 397 666 666 862 862 1567 1567
219 219 470 470 470 470 1410 1410
Inlet
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
Natural Gas Chart
Model 325 With OPD Capacity Table in SCFH of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F)
MFR#
Pipe size
325-3l47
3/8”
325-3l47
1/2”
325-3l48
1/2”
325-5al48
1/2”
325-5al48
3/4”
325-5al600
3/4”
325-5al600
1”
outlet pressure
1/2 PSI
3/4 PSI
Inlet
1 PSI Inlet
5 PSI Inlet
Max Load Multiple appliances
max individual appliance load
7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c.
125 100 125 105 160 120 235 235 320 245 345 260 375 285
125 125 125 125 200 200 235 235 320 320 425 425 465 465
125 125 125 125 200 200 235 235 320 320 425 425 465 465
125 125 125 125 200 200 235 235 320 320 425 425 465 465
125 125 125 125 200 200 235 235 320 320 425 425 465 465
125 125 125 125 200 200 235 235 320 320 425 425 465 465
Inlet
Propane Gas Chart*
Model 325 with OPD Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas (1.5 Specific Gravity — 14.65 psia — 60°F)
MFR#
Pipe size
325-3l47
3/8”
325-3l47
1/2”
325-3l48
1/2”
325-5al48
1/2”
325-5al48
3/4”
325-5al600
3/4”
325-5al600
1”
outlet pressure
1/2 PSI
3/4 PSI
Inlet
1 PSI Inlet
5 PSI Inlet
Max Load Multiple appliances
max individual appliance load
7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c. 7” w.c. 10” w.c.
196 157 196 165 251 188 368 368 502 384 541 408 588 447
196 196 196 196 313 313 368 368 502 502 666 666 729 729
196 196 196 196 313 313 368 368 502 502 666 666 729 729
196 196 196 196 313 313 368 368 502 502 666 666 729 729
196 196 196 196 313 313 368 368 502 502 666 666 729 729
196 196 196 196 313 313 368 368 502 502 666 666 729 729
Inlet
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
27
regulators & accessories
(1.5 Specific Gravity — 14.65 psia — 60°F)
SECTION
1
Regulators Rubber Seat Poppet Design Appliance Regulators — RV12, RV20, RV47 & CV47 and RV48 Main burner and pilot applications MFR#
pipe sizes
capacities to
1/8”
1/2” & 3/4”
25 CFH 65 CFH 125 CFH 250 CFH
RV12 RV20 RV47 & CV47 RV48
RV12
1/4” & 3/8” 3/8” & 1/2”
MFR#
RV20
RV47 & CV47
RV48
inlet pressures to 1/2 psi (35 mbar) 1/2 psi
1/2 psi (35 mbr)
body sizes
Qty. per case
webb#
RV20L-38
3/8”
100
185902
RV47CL-12
1/2”
50
185903
RV47CL-38
3/8”
50
188932
RV47L-12
1/2”
50
197256
RV47L-38
3/8”
50
188933
RV48CL-12
1/2”
50
185905
RV48CL-34
3/4”
50
185904
RV48L-12
1/2”
50
185907
RV48L-34
3/4”
50
185906
body sizes
Qty. per case
STD. SPRING
SET POINT
webb#
RV20L-38
3/8"
100
3-5" wc
4"
185902
RV48CL-12
1/2"
50
None
fixed 4 or 10"
185903
RV47CL-38
3/8"
50
None
fixed 4 or 10"
188932
RV47L-12
1/2"
50
4-12"
11"
197256
RV47L-38
3/8"
50
4-12"
11"
188933
RV48CL-12
1/2"
50
None
fixed 4 or 10"
185905
RV48CL-34
3/4"
50
None
fixed 4 or 10"
185904
RV48L-12
1/2"
50
4-12"
11"
185907
RV48L-34
3/4"
50
4-12"
11"
185906
RV48-12
1/2"
50
3-6"
4"
77528
RV48-34
3/4"
50
3-6"
4"
77529
MFR#
outlet pressures 1.0” to 12” w.c.
Natural Gas Chart
Poppet RV Regulator (Appliance Regulators) Capacity Table in SCFH of Natural Gas (0.64 Specific Gravity — 14.65 psia — 60°F) (Min. Capacity on all models is 150 btu/hr)
MFR# rv12 rv20 rv47 rv47c rv48 rv48 rv48c rv48c
28
Pipe size 1/8”
1/4” or 3/8” 3/8” or 1/2” 3/8” or 1/2” 1/2” 3/4” 1/2” 3/4”
max capacity at .3” w.c. Pressure drop
Suggested Max Supply for Main burner only
Suggested Max Supply for Main burner only and Pilot
max individual load with fixed orifice vent limiter
max individual load with ball check vent limiter
15 30 30 60 130 150 130 150
30 65 125 125 230 230 400 400
25 50 90 125 230 250 275 275
20 30 40 40 40 40 40 40
— — 90 125 160 160 160 160
Gas Equipment Catalog
victormfg.com
SECTION
1
Regulators
Propane Gas Chart*
Poppet RV Regulator (Appliance Regulators) Capacity Table in 1000’s of BTU’s of Undiluted Propane Gas
MFR#
Suggested Max Supply for Main burner only
Suggested Max Supply for Main burner only and Pilot
max individual load with fixed orifice vent limiter
max individual load with ball check vent limiter —
Pipe size
max capacity at .3” w.c. Pressure drop
1/8”
23
47
39
31
47
102
78
47
—
3/8” or 1/2”
47
196
141
63
141
94
196
196
63
196
1/2”
204
361
361
63
251
235
361
392
63
251
204
627
392
63
251
235
627
392
63
251
rv12 rv20 rv47 rv47c rv48 rv48 rv48c rv48c
1/4” or 3/8” 3/8” or 1/2” 3/4” 1/2” 3/4”
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
Rubber Seat Poppet Design Appliance Regulators — RV12, RV20, RV47 & CV47 and RV48 DESCRIPTION
USE WITH REGULATOR
WEBB #
MXTR325C10-1022
MFR#
Spring Red 10-22 325-3
325-3
185891
MXTR325C10-1530
Spring Yellow 15-30 325C
325-3
197075
MXT325E-10A-1022
Spring Red 10-22” 325-5A
325-5A
110108
MXTR325E10-26A
Springs 2 to 6 lbs
325-5A
309740
MXTR325E10-412
Spring Violet 4-12
325-5A
185893
MXTR325E10-P12
Spring Tagged
325-5A
185894
MXTR4810-512
Spring Blue 5-12 RV48
RV48
185889
MXTR6110-1022
Maxitrol Spring 10 to 12
RV61
254238
MXTR8110-1022
Spring Red
RV81/210D
192815
MXTR8110-1530
Spring Yellow 15-30 210D
RV81/210D
196945
MXTR8110-2042
Spring Black 20-42
RV81/210D
185897
MXTR8110-412
Spring Violet 4-12 RV
RV81/210D
196956
MXTR8110-512
Spring Blue 5-12
RV81/210D
185898
MXTR8110-515
Spring Green 5-15 RV881 210
RV81/210D
196987
MXTR9110-1022
Spring Red 10-22
RV91/210E
185899
MXTR9110-1530
Spring Yellow 15-30” 210E
RV91/210E
196947
MXTR9110-412
Spring Violet 4-12” Spring
RV91/210E
199275
MXTR9110-512
Spring Blue 5-12
RV91/210E
309737
Victor/F.w. Webb offers webbConnect! you can order, check current pricing and inventory 24/7!
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
29
regulators & accessories
(1.5 Specific Gravity — 14.65 psia — 60°F)
1
SECTION
2
Cylinder & Service Valves Cylinder Valve for RV and Small ASME System Vapor Withdrawal
Designed especially for vapor withdrawal service in small ASME containers with surface area up to 23.8 square feet. UL flow capacity is 645 CFM/air, per NFPA 58.
MFR#
9106CO
9106CO
FIXED LIQUID PresSure LEVEL relief container Service VENT VALVE valve connection Connection STYLE setting 3/4” M. NPT
F. POL CGA 510
None
for use in cylinders with propane capacity up to
312 PSIG
flow capacity SCFM/AIR Webb#
ASME Tanks*
645
186998
* Surface area up to 23.8 square feet.
Cavagna OPD Valve
VCT80-8169
Type 1 valves intended for DOT cylinders up to 40 lbs. LP Gas capacity. This valve has a vapor service outlet, relief valve, captive fixed liquid level gauge, and an overfill prevention device. Type 1 ACME and POL Outlet thread: 4.0 inches Dip tube length: 375 PSI Setting pressure: No Flow limiter: No Plastic cap: Inlet thread: 3/4 Pressure relief valve: Yes Gas type: LP-Gas Packaging: 28 Availability: Yes MFR#
size
Webb#
VCT80-8169
20#
395314
VCT80-9-890-8128
30#
401280
VCT80-9-890-8185
40#
399370
Heavy Duty Cylinder Valves for Vapor Withdrawal This heavy duty cylinder valve is designed for vapor withdrawal of DOT cylinders up to 100 lbs. propane capacity. It is used in domestic hookups, with RV’s and as a heavy duty barbeque cylinder valve.
MFR#
9103D11.6
9103D10.6 9103D11.6
CONTAINER CONNECTION
Service CONNECTION
FIXED LIQUID LEVEL VENT VALVE STYLE
3/4” M. NPT
F. POL CGA 510
Knurled
DIP TUBE PresSure LENGTH relief WITH valve DEFLECTOR setting 10.6” 11.6”
for use in cylinders with propane capacity up to
375 PSIG
100 lbs.
approximate filling rate liquid flow, gpm pressure drop across valves MFR# 9103D10.6 9103D11.6
30
accessories
10 PSIG
25 PSIG
50 PSIG
100 PSIG
POL PLUG
12.7
20.3
29.0
41.3
N970P
Gas Equipment Catalog
Webb# 162726 162727
victormfg.com
SECTION
2
Cylinder & Service Valves Cylinder Valve for Liquid Withdrawal Equipped with excess flow valves and liquid withdrawal tubes, they are designed for liquid withdrawal of DOT cylinders up to 100 lbs. propane capacity. They are most often used with heavy BTU loads found in industrial uses. MFR#
CONTAINER CONNECTION
Service CONNECTION
FIXED LIQUID LEVEL VENT VALVE STYLE
DIP TUBE LENGTH WITH DEFLECTOR
liquid withdrawAl tube length
3/4” M. NPT
CGA 555
Knurled
11.6”
44”
9107K8A
MFR#
9107K8A With Dip Tube
Pressure relief valve setting
For use in cylinders with propane capacity up to
10 psig
375 PSIG
100 lbs.
3.3
9107K8A
closing flow (LP-Gas)*
Pressure drop across valves
vapor
25 50 100 25 psig psig psig psig inlet 5.4
7.7
100 psig inlet
525 SCFH
11.1
liquid Webb#
1,000 SCFH
1.7 GPM
162728
* Closing flows based on 3/8” O.D. withdrawal tube 44” long or less attached. IMPORTANT: 1/4” O.D. pigtails or POL connections for 1/4” O.D. pigtails should not be used with these valves. NOTES: To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use. These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.
“Dual” Cylinder Valve for Simultaneous Liquid and Vapor Withdrawal The dual cylinder valve was designed especially for industrial uses. It increases the cylinder’s flexibility by permitting DOT cylinders up to 100 lbs. propane capacity to be used interchangeably or simultaneously for either liquid or vapor withdrawal. MFR# 8556
MFR# 8556
Service Connection
container connection
VAPOR
3/4” M. NPT
F. POL CGA 510
Pressure relief valve setting
For use in cylinders with propane capacity up to
375 PSIG
100 lbs.
LIQUID
FIXED LIQUID LEVEL VENT VALVE STYLE
LIQUID WITHDRAWAL TUBE LENGTH
CGA 555
None
44”
approximate filling rate liquid flow, GPM Pressure drop across valves 10 psig
25 psig
50 psig
100 psig
Liquid closing flow* (LP-Gas)
Webb#
6.6
10.0
14.5
21.0
2.3 GPM
189194
* To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use. NOTE: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.
Service Valves for ASME and DOT Containers or Fuel Line Applications
9101C
MFR#
9101R11.7
BONNET STYLE
Designed especially for vapor withdrawal service on ASME and DOT containers or in fuel line applications. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that container’s capacity.
container connection
service connection
9101C1 9101DT11.1
Standard
9101DT11.7 9101R11.7
MultiBonnet
3/4” M. NPT
F. POL CGA 510
FIXED LIQUID LEVEL VENT VALVE
APPROXIMATE FILLING RATE liquid flow, gpm pressure drop across valve 10 PSIG
25 PSIG
50 PSIG
100 PSIG
Webb#
No
8.8
12.4
15.8
21.7
186993
Yes
8.6
12.7
16.3
22.3
Yes
7.6
11.7
15.2
20.6
273828 273829 162724
NOTE: These valves incorporate an excess flow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess flow valves.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
31
valves & accessories
approximate filling rate liquid flow, GPM
2
SECTION
2
Cylinder & Service Valves
Service Valve for DOT Fork Lift Containers Designed especially for vapor or liquid withdrawal service on DOT fork lift containers. Valves with 1.5 GPM closing flow are for use in small and medium size lift truck applications, while those with 2.6 GPM closing flow are for large lift trucks and gantry crane type vehicles. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that cylinders capacity. The integral excess flow valve found in all these service valves helps prevent excessive product loss in the event of fuel line rupture. When installed for liquid withdrawal, the 9101P6 Series has provisions for attachment of a liquid withdrawal tube. The 9101P5 Series must be installed in containers that have provisions for a separate liquid withdrawal. 9101P5
CLOSING FLOW (LP-GAS)
MFR#
CONTAINER CONNECTION
Service CONNECTION
9101P5 9101P5H 9101P6
3/4” M. NPT
3/8” M. NPT 1/4” NPT
9101P5H 9101P6 9101P6H
100 PSIG INLET (SCFH)
LIQUID (GPM)
430
900
1.5
550
1050
2.6
430
900
1.5
550
1050
2.6
approximate filling rate liquid flow, gpm
accessories
pressure drop across valves
ACME CHECK CONNECTORS
9101P6 9101P5
25 PSIG INLET (SCFH)
None
9101P6H
MFR#
VAPOR
LIQUID WITHDRAWAL CONNECTION
10 PSIG
25 PSIG
50 PSIG
100 PSIG
5.0
7.6
10.7
14.9
Male
7.2
10.3
CAP
7141F
7141M-40 or 7141FP
Webb# 162720
7141M 4.5
FEMALE
14.8
162721 186995 190685
To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use.
Service Valves for ASME Motor Fuel Containers
9101H5
Designed specifically for vapor or liquid withdrawal service on ASME motor fuel containers. Since none of these valves have an integral pressure relief valve, they may only be used as an accessory valve on containers that have an independent pressure relief valve sufficient for that container’s capacity. The integral excess flow valve found in all these service valves helps prevent excessive product loss in the event of fuel line rupture. When installed for liquid withdrawal, the 9101H6 has provisions for attachment of a liquid withdrawal tube. All other valves must be installed in containers that have provisions for a separate liquid withdrawal. CLOSING FLOW (LP GAS)
9101H6 MFR#
VAPOR LIQUID container Service WITHDRAWAL 25 PSIG 100 PSIG LIQUID connection Connection CONNECTION INLET (SCFH) INLET (SCFH) GPM Webb#
9101H5* 9101H6* 9101Y5H*
9101Y5H
3/4” M. NPT
* SAE Flare 60° Angle * SAE Flare
None
765**
1300**
3.6**
162499
1/4” NPT
550****
1050****
2.6****
189199
None
550**
1050**
3.6**
162500
*Heavy-duty models. **Based on 3/8” O.D. pigtail, 20” long or less, connected to valve outlet. For greater lengths the pigtail must have a larger O.D. ***Same as (**) . In addition, 1/4” O.D. pigtails or POL connections for 1/4” O.D. should not be used with this valve. ****Based on 3/8” O.D. pigtail: 20” long or less, connected to valve outlet. Also based on 1/4” pipe size dip tube, 42” long or less, attached to special inlet connection. For longer pigtail lengths, the diameter of the pigtail must be increased. To ensure proper functioning and maximum protection from excess flow valves, the cylinder valve should be fully opened and backseated when in use.
32
Gas Equipment Catalog
victormfg.com
SECTION
2
Multivalve Assemblies ASME Multivalves® for Vapor Withdrawal These Multivalves® are designed for use in single opening ASME containers equipped with a 21/2” M. NPT riser. They can be used with underground ASME containers up to 639 sq. ft. surface area, and above ground ASME containers up to 192 sq. ft. surface area. A separate opening is required for liquid withdrawal. The MultiBonnet® is standard on this valve. The MultiBonnet® allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM
2
Pressure Drop across valves 10 psig
25 psig
50 psig
100 psig
42
72
98
125
G8475RV
G8475RW
G8475RW
VAPOR EQUALIZING CONNECTION MFR# G8475RV G8475RW
CONTAINER CONNECTION
SERVICE CONNECTION
FILLING CONNECTION
CONNECTION SIZE
UL LISTED CLOSING FLOW
FLOAT GAUGE FLANGE OPENING
21/2” F. NPT
F. POL CGA 510
13/4” M. Acme
11/4” M. Acme
4200 CFH at 100 PSIG
Fits “Junior” Size
FIXED LIQUID LEVEL VENT VALVE STYLE
MFR# G8475RV
Knurled
Pressure relief valve DIP TUBE LENGTH
MFR#
UL
ASME
FOR USE IN *CYLINDERS WITH SURFACE AREA UP TO
M3131G
2020 SCFM/air
1939 SCFM/air
83 sq. ft. Above Ground 276 sq. ft. Underground
187104
MV3132G
3995 SCFM/air
n/a
192 sq. ft. Above Ground 639 sq. ft. Underground
190680
Flow Capacity SETTING
30”*
250 PSIG
G8475RW
Webb#
* Dip tube not installed, may be cut by customer to desired length.
For specific repair parts, see the end of this section.
ASME Multivalves® for Vapor Withdrawal These Multivalves® provide vapor withdrawal and filling of ASME containers. A separate pressure relief valve is required in addition to this valve. The MultiBonnet® is standard on this valve. MultiBonnet® allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM Pressure Drop across valves
8593AR16.0
MFR# 8593AR16.0
10 psig
25 psig
50 psig
100 psig
Webb#
42
72
98
125
162498
VAPOR EQUALIZING CONNECTION
MFR# 8593AR16.0
CONTAINER SERVICE CONNECTION CONNECTION 11/2” M. NPT
F. POL CGA 510
FILLING CONNECTION CONNECTION SIZE 13/4” M. Acme
11/4” M. Acme
UL LISTED CLOSING FLOW
Fixed liquid level vent valve style
dip tube length
for use in Containers with surface area up to:
Knurled
16”*
**
4200 CFH at 100 PSIG
* Dip tube not installed, may be cut by customer to desired length. ** Since these Multivalves® have not integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
33
valves & accessories
MFR#
SECTION
2
Multivalve Assemblies DOT Multivalves® for Liquid Withdrawal
These Multivalves® permit liquid withdrawal from DOT cylinders with up to 100 lbs. propane capacity. They eliminate unnecessary cylinder handling when servicing high volume loads and allow on-site filling into the vapor space without interrupting gas service. Approximate Filling Rate Liquid Flow, GPM Pressure Drop across valves MFR# 8555dl11.6
10 psig
25 psig
50 psig
100 psig
8
23
34
42
8555DL11.6 MFR#
CONTAINER SERVICE CONNECTION CONNECTION
8555dl11.6
MFR#
3/4” M.NPT
CGA 555*
FILLING CONNECTION
Fixed liquid level vent valve style
dip tube length with deflector
13/4” M. Acme
Knurled
11.6”
liquid withdrawal tube length
pressure relief valve setting
for use in cylinders with propane capacity up to
liquid closing flow (Lp. gas)***
Webb#
44”
375 PSIG
100 lbs.**
1.7 GPM
162734
8555dl11.6
*Use adapter 12982 to connect to pipe threads. **Per CGA Pamphlet S-1.1. ***To ensure proper functioning and maximum protection from integral excess flow valves, the cylinder valve should be fully opened and backseated when in use. ®
DOT Multivalves for Vapor Withdrawal
These Multivalves® permit vapor withdrawal from DOT cylinders with up to 200 lbs. propane capacity. They allow on-site cylinder filling without interrupting gas service. The MultiBonnet® option allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM Pressure Drop across valves MFR#
25 psig
50 psig
100 psig
Webb#
6555r11.6
359339
6555r12.0
—
8555d10.6
162732
8555R10.6
162740
8555d11.6
8555D11.6
10 psig
8
23
34
42
162733
8555R11.6
162741
8555dt10.6
273825
8555dt11.6
273826
8555dt8.2
273827
T = Threadsealent
bonnet style
application
for use in containers with size up to
dip tube length with deflector
6555r11.6
MultiBonnet
ASME Containers
25 ft. Surface Area or 60 Gallons Water Capacity
11.6”
8555D10.6
Standard
8555R10.6
MultiBonnet
8555D11.6
Standard
8555R11.6
MultiBonnet
MFR#
10.6”
DOT Containers
200 lbs. Propane
8555DT10.6 8555DT11.6
11.6”
3/4” M. NPT
10.6” Standard
11.6”
8555DT8.2
34
container connection
8.2”
Gas Equipment Catalog
victormfg.com
SECTION
2
Multivalve Assemblies DOT Multivalves® for Liquid Withdrawal (continued)
PRessure relief valve
MFR#
fixed flow liquid capacity* level service filling vent ul connection connection style setting listing asme 793 SCFM/ air
700 SCFM/ air
359339
8555D10.6
162732
8555R10.6
162740
8555D11.6
F. POL CGA 510
13/4” M. Acme
Knurled
162733 375 PSIG
8555R11.6
n/a
n/a
162741
8555DT10.6
273825
8555DT11.6
273826
8555DT8.2
273827
T = Threadsealent * Per CGA Pamphlet S-1.1.
DOT and ASME Multivalves® for Vapor Withdrawal These Multivalves® permit vapor withdrawal from ASME containers up to 50 sq. ft. surface area and DOT containers up to 420 lbs. propane capacity. They allow on-site cylinder filling without interrupting gas service. The MultiBonnet® option allows quick and easy repair of bonnet. Approximate Filling Rate Liquid Flow, GPM Pressure Drop across valves
6543A11.7
MFR# 6532A12.0 6532R12.0 6542A12.0 6542R12.0 6533A11.7 6533R11.7
10 psig
25 psig
50 psig
11
16
23
23
32
46
11
16
23
100 psig
— 162735 373827 162737 28
6543A11.1 6543R11.1 6543A11.7
Webb#
162729 162736 162730
23
32
162738
46
162731
6543R11.7
162739
6543AT10.3
—
—
—
—
273821
6543AT11.7
—
—
—
—
275093
T = Threadsealent
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
35
2 valves & accessories
250 PSIG
6555r11.6
webb#
SECTION
2
Multivalve Assemblies DOT and ASME Multivalves® for Vapor Withdrawal (continued) MFR#
bonnet style
6532A12.0
Standard
6532R12.0
MultiBonnet
6542A12.0
Standard
6542R12.0
MultiBonnet
6533A11.7
Standard
6533R11.7
MultiBonnet
6543A11.1
Standard
6543R11.1
MultiBonnet
6543A11.7
Standard
6543R11.7
MultiBonnet
MFR#
application
container connection
Service connection
fiLling connection
Fixed Liquid level Vent valve style
F.POL CGA 510
13/4” M. Acme
Knurled
3/4” M. NPT
ASME* 1” M. NPT 3/4” M. NPT
DOT 1” M. NPT
dip tube length with deflector
pressure relief valve setting
for use in cylinders with propane capacity**
For use in containers with surface area up to***
6532A12.0
—
43 sq. ft.
6532R12.0
12.0”
6542A12.0
250 PSIG
162735
—
373827
53 sq. ft.
6542R12.0 6533A11.7
162737 162729
11.7”
6533R11.7 6543A11.1
162736
11.1”
6543R11.1 6543A11.7
375 PSIG
420 lbs. Propane
162730
—
162738 162731
11.7”
6543R11.7
WEBB#
162739
* UL rated flow capacities are 6532A 12.0-1180 SCFM/air, 6542A 12.0-1530 SCFM/air. ** Per CGA Pamphlet S-1.1. *** From NFPA 58, Appendix D.
ASME Multivalves® for Vapor Withdrawal These compact Multivalves® are especially suited for vapor withdrawal of ASME containers where compact groupings of components are necessary. Separate filler valves and pressure relief valves are required. MultiBonnet® allows quick and easy repair of bonnet. VAPOR EQUALIZING CONNECTION
7556R12.0
MFR# 7556R12.0
CONTAINER CONNECTION
SERVICE CONNECTION
CONNECTION SIZE
UL LISTED CLOSING FLOW
3/4” M. NPT
F. POL CGA 510
11/4” M. Acme
4200 CFH at 100 PSIG
7556ZT MFR# 7556R12.0
Special/Thread Connection O-Ring fixed liquid level vent valve style
dip tube length
for use in containers with surface up to
webb#
Knurled
12”
*
162742
7556ZT
—
—
* Since these Multivalves® have no integral pressure relief valves, they can be used on any ASME container with an independent relief device sufficient for that tank’s capacity.
36
Gas Equipment Catalog
victormfg.com
SECTION
2
Pressure Relief Valves & Relief Valve Manifolds Fully Internal “Pop-Action” Pressure Relief Valves for Transport and Delivery Trucks Designed specifically for use as a primary relief valve in ASME transports and delivery trucks with 2” and 3” NPT couplings. A8434G
Start to discharge setting Container PSIG Connection
Overall height
Height Above Coupling
(approx.)
(approx.)
Ul
ASME
(at 120% of Set Pressure)
Suitable for Tanks with Protective Surface cap (included) webb# Area up to*
A8434G
250
2” M. NPT
91/16”
1/2”
3700
3456
175 sq. ft.
A8434-11B
187081
A8436G
250
3” M. NPT
17”
3/4”
10210
9598
602 sq. ft.
A8436-11B
162575
* Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME flow rating—whichever is larger.
Fully Internal “Pop-Action” Pressure Relief Valves for Motor Fuel Containers 8544T
8543 Series relief valves are designed for use as a primary relief valve in larger ASME motor fuel containers such as on buses, trucks and construction equipment. 8544 Series relief valves are designed for use as a primary relief valve in smaller ASME and DOT motor fuel containers such as on tractors, lift trucks, cars and taxicabs.
MFR#
Container type
Start to discharge setting PSIG
8544G 8543G
ASME
1”
DOT/ASME
375
1”
8544GT
ASME
250
1”
8544KT
DOT/ASME
375
1”
Flow capacity SCFM/AIR***
MFR#
hex wrenching Section
8544G
15/16”
1020
8543G
111/16”
8544T
Height Above Coupling
57/16”
7/8”
(approx.)
(approx.)
11/4”
312
8544K
Ul
Overall height
1”
250
8544T
Container Connection m. npt
ASME
accessories Protective Cap (included)
pipeaway adapter
webb#
936
7544-41
7544-11A*
162757
1465
1400
7543-40C
7543-10**
189192
15/16”
1282
1158
7544-41
7544-11A
189193
8544K
15/16”
1545***
—
7544-41
7544-11A
162758
8544GT
15/16”
1020
936
7544-41
7544-11A
273823
8544KT
15/16”
1545***
—
7544-41
7544-11A
273824
(at 120% of Set Pressure)
T = Threadsealent *1” M.NPT outlet connection. **11/4” M.NPT outlet connection. ***Rating also applies to DOT requirements. ****Flow rates shown are for bare relief valves. Adapters and pipeaway will reduce flow as discussed in forewording information.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
37
valves & accessories
MFR#
2
SECTION
2
Pressure Relief Valves & Relief Valve Manifolds
Fully Internal “Pop-Action” Pressure Relief Valve for DOT Fork Lift Cylinders Designed specifically for use as a primary relief valve on forklift cylinders, the 8545AK reduces the possibility of improper functioning of the relief mechanism due to foreign material build up. All guides, springs, stem and adjusting components are located inside the cylinder — removed from the direct exposure of foreign materials and debris from the atmosphere.
8545AK With Protective Cap
MFR# 8545AK
Start to Container discharge Type setting PSIG Dot
Container connection m. npt 3/4”
375
Flow Capacity scfm/Air**
Accessories (ORder Separately) Deflectors***
(ECII® Rated at 480 PSIG)
Protective cap
45º Elbow
90º Elbow
WEBB#
400*
7545-40
7545-14A
7545-12
162759
* Classified by U.L. in accordance with Compressed Gas Association Pamphlet S-1.1 Pressure Device Standards for Cylinders. Meets requirements for use on DOT containers with 262 pounds or less weight of water or 109 pounds or less of LP-Gas. ** Flow rates are shown for bare relief valves. Adapters and pipeaways will reduce flow as discussed in forewording information. *** Order protective cap #8545-41 or 7545-40.
Semi-Internal “Pop-Action” Pressure Relief Valve for ASME Containers Designed specifically for use as a primary relief valve on ASME containers such as 250, 500 and 1,000 gallon tanks. Underwriters’ Laboratories lists containers systems on which these types of valves are mounted outside the hood without additional protection, if mounted near the hood and fitted with a protective cap.
MFR#
Start to discharge setting PSIG
7583G 8684G
7583G
250
8685G
Container Connection M. NPT
Overall height
3/4”
1” 11/4”
Flow Capacity SCFW/AIR Ul MFR#
38
ASME
(at 120% of Set Pressure)
Height Above Coupling (approx.)
Wrench Hex Section
83/16”
17/16”
13/4”
93/8”
19/16”
17/8”
111/16”
111/16”
23/8”
(approx.)
Suitable for Tanks with Surface Area up to
Protective cap (included)
webb#
7583G
1980
1806
80 sq. ft.
7583-40X
162747
8684G
2620
2565
113 sq. ft.
8684-40
162749
8685G
4385
4035
212 sq. ft.
7585-40X
162750
Gas Equipment Catalog
victormfg.com
SECTION
2
Pressure Relief Valves & Relief Valve Manifolds Semi-Internal “Pop-Action” Pressure Relief Valve for Large Storage Containers Designed specifically for use as a primary relief valve on large stationary storage containers, these low profile relief valves are generally mounted in half couplings. However, they are designed so that the inlet ports clear the bottom of a full 2” coupling. This assures that the relief valve should always be capable of maximum flow under emergency conditions.
7534-40
7534-20
Flow capacity SCFM/AIR* UL
MFR#
Start to discharge setting PSIG
Container Connection
7534G
250
2” M. NPT
ASME
(at 120% of Set Pressure)
11675
accessories
Suitable for tanks with surface area up to**
protective cap
pipeaway adapter
webb#
708 sq. ft.
7534-40
7534-20***
162574
10422
* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow as discussed in the forewording information. ** Per NFPA Pamphlet #58, Appendex D. Area shown is for UL or ASME—whichever is larger. *** 3” F.NPT outlet connection.
External “Pop-Action” Supplementary Pressure Relief Valves for Small Containers and DOT Cylinders
3127 Series
MFR#
Designed for use as a supplementary relief valve on small ASME above ground and underground containers. They may also be used as a primary or secondary relief device on DOT cylinders, or as hydrostatic relief valves. All working components of these relief valves are outside the container connection, so the valves must be protected from physical damage.
3127G
Container Type
Start to discharge setting PSIG
ASME
250
3127G 3129G 3127K
DOT
3129K
Container Connection M. NPT
Overall Height (Approx.)
Wrench HEx Section
1/4”
131/32”
7/8”
1/2”
219/32”
11/8”
1/4”
131/32”
7/8”
1/2”
219/32”
11/8”
375
Flow capacity SCFM/AIR* UL
MFR#
(at 120% of Set Pressure)
3127G
295
3129G
465
3127K 3129K
ASME
—
—
accessories Suitable for tanks with surface area up to*
pipeaway adapter protective cap
—
—
450
100 lbs./Propane
780
200 lbs./Propane
Outlet Size
MFR#
7545-40
162420 1/2” F. NPT
3129-10 — 3129-10
webb# 162429 162424
1/2” F. NPT
—
* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
39
valves & accessories
7534G
2
SECTION
2
Pressure Relief Valves & Relief Valve Manifolds
3135-10
External “Pop-Action” Pressure Relief Valve for ASME Containers and Bulk Plant Installations Designed for use as a primary relief valve on ASME above ground and underground containers, bulk plant installations and skid tanks. The 3131 Series may also be used as a primary or secondary relief valve on DOT cylinders, or as a hydrostatic relief valve. All working components of these relief valves are outside the container connection, so the valves must be protected from physical damage. Flow Capacity SCFW/AIR (a)
3135 AA3135
MFR# AA3126L030
Start to discharge setting PSIG 30
AA3126L250 3131G W3132G MV3132G
Overall height (approx.)
Wrench Hex Section
1/2”
2”
—
3/4”
AA3130UA250 3132G
Container Connection M. NPT
11/4”
AA3135UA250
Suitable for Tanks with Surface area up to (e) —
AA3126L250
23 sq. ft. (f)
AA3130UA250
521/32”
277 (c)
—
2060
1939
2045
1838
4130
—
211/16”
5770
—
6430
5080 (d)
6080
—
101/2”
41/8”
10390
9153
37/16”
103/4”
2125
1912
515/16”
21/2” 3/4”
accessories pipeaway adapter protective cap
MFR#
outlet size
7545-40
AA3126-10
1/2” M. NPT
85 sq. ft.
3131-40 (g)
249 sq. ft. (f)
AA3130-40P
weep hole deflector
webb# 187092
—
—
187093 162436
AA3131-10
1” F. NPT
187095
3132-10
11/4” F. NPT
162444
3132G
200 sq. ft.
MV3132G
190 sq. ft.
3135G
300 sq. ft.
3135-54 (g)
3135-10
1010 sq. ft. (f)
AA3135-40PR
AA3135-10
3133G
320 sq. ft.
3133-40 (g)
—
A3149G
613 sq. ft.
3149-40
261 sq. ft. (f)
AA3130-40P
(b) (c) (d) (f ) (g) (h) (j)
—
31/8”
11/2”
154 sq. ft.
AA3130UA265
(b)
3995
W3132G
AA3135UA250
40
265
AA3126L030 3131G
2”
613/32”
A3149G
ASME
(at 120% of Set Pressure)
3340 61/32”
250
3133G
MFR#
13/4”
1”
3135G
AA3130UA265
37/16”
UL
3132-54 (g)
162442
— 3133-11 2” F. NPT
162447 190683 162446
(h) AA3131-10
188588
1” F. NPT
Included (j)
162572
—
189239
Not UL or ASME rated. .059 sq. in. effective area. Not UL or ASME rated. ECII® rated at 120% of set pressure. Rated at 110% of set pressure. Per ANSI K61.1-1972. Appendix A Cap supplied with chain. Outlet 31/2-8N (F) thread, will accept 3” M. NPT pipe thread. Weep hole deflector is Part No. A3134-11B.
Gas Equipment Catalog
victormfg.com
SECTION
2
Pressure Relief Valves & Relief Valve Manifolds External Hydrostatic Relief Valves Designed especially for protection of piping and shut-off valves where there is a possibility of trapping liquid LP-Gas or anhydrous ammonia. They may be installed in pipelines and hoses located between shut-off valves or in the side of boss in RegO® shut-off valves.
2 SS8022G Accessories
MFR#
Start to discharge setting PSIG
Valve Body Material
SS8001G
1/4”
SS8002G SS8021G SS8022G
Container Connection M. NPT
250
Stainless Steel
1/2” 1/4” 1/2”
Height
(Approx.)
— 1”
Wrench Hex Section
pipeaway protective adapter or cap threads (included)
11/16”
— 11/16”
— —
—
webb# 283973 189248
1/4” NPSM Thrds
162494
3/8” NPT Thrds
189249
—
162420
3127G
1/4”
131/32”
3129G
1/2”
219/32”
1”
3129-10
162429
1/4”
131/32”
7/8”
—
162422
1/2”
219/32”
11/8”
3129-10
186844
1/4”
131/32”
7/8”
—
186843
1/2”
219/32”
11/8”
3129-10
—
3127J
1/4”
131/32”
7/8”
—
162423
3129J
1/2”
219/32”
11/8”
3129-10
162430
1/4”
—
11/16”
—
187114
1/4” NPSM Thrds
193305
3/8” NPT Thrds
187116
—
162424
3129-10
—
3127H 3129H 3127P 3129P
SS8001J
275 Brass 300
350
SS8021J SS8022J 3127K 3129K
Stainless Steel
375 Brass
3125L 3127L 3129L SS8001L
400 Stainless Steel
SS8021L SS8022L 3127U
Brass
3129U SS8001U SS8002U SS8021U SS8022U
450
1/4” 1/2”
11/16”
—
7/8”
1/4”
131/32”
1/2”
219/32”
11/8”
19/16”
5/8”
3125-40P
131/32”
7/8”
7545-40
1/2”
219/32”
11/8”
3129-40P
1/4”
7/8”
11/16”
1/4”
1/4” 1/2”
13/8”
1/4”
131/32”
1/2”
219/32”
1/4”
Stainless Steel
1”
7545-40
1/2” 1/4” 1/2”
— 1”
11/16”
7545-40
—
— 1”
7545-40
11/16”
— 11/16”
—
—
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
162426
3129-10
—
—
—
1/4” NPSM Thrds
162495
3/8” NPT Thrds
—
—
162428
3129-10
162432
— —
162751
162490 —
1/4” NPSM Thrds
162496
3/8” NPT Thrds
189250
41
valves & accessories
3127G
SECTION
2
Pressure Relief Valves & Relief Valve Manifolds
DuoPort® Pressure Relief Valve Manifolds for Small Storage Containers Designed especially for use as a primary relief device on smaller stationary storage containers, with 2” NPT threaded couplings. These manifolds allow servicing or replacement of either of the two relief valves without evacuating the container or loss of service. The operating lever selectively closes off the entrance port to the relief valve being removed while the remaining valve provides protection for the container and its contents. The rating of each manifold is based on actual flow through the manifold and a single pressure relief valve, taking friction loss into account, it is not merely the rating of the relief valve alone. AA8542UA250
MFR#
start discharge setting psig
application lp-gas
8542G
250
AA8542UA250
250
nh3
Container connection M. NPT
Yes
No
2”
No
Yes
2”
flow capacity scfm/air** (at 120% of set pressure)
Relief valve included MFR#
quantity
MFR#
inlet connection M. NPT
Accessory
8542G
2
3135MG
11/4”
3135-10*
5250 (1)
NA
189191
AA8542UA250
—
—
—
—
—
—
189245
pipeaway adaptors
UL rating
asme rating
webb#
* 2” F. NPT outlet connection. ** Flow rating based on number of relief valves indicated in parenthesis ( ). Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce flow rates as discussed in forewording information.
Multiport® Pressure Relief Valve Assemblies for Large Storage Containers Designed especially for use as a primary relief device on large stationary pressurized storage containers with flanged openings. These manifolds incorporate an additional relief valve, not included in the flow rating, allowing for servicing or replacement of any one of the relief valves without evacuating the container. The handwheel on the manifold selectively closes off the entrance port to the relief valve being removed while the remaining relief valves provide protection for the container and its contents. All manifold flow ratings are based on flow through the relief valves after one has been removed for service or replacement. start discharge setting psig
MFR#
application lp-gas
nh3
A8564G
3” - 300#
A8574G
A8564G
250
A8564AG
Yes
Yes
A8574AG
quantity
A8564G A8574G A8564AG A8574AG
42
MFR#
3” - 300#
flow capacity scfm/air
inlet connection M. NPT
(at 120% of set pressure)
Accessory pipeaway adaptors
A3149MG 4
4” - 300# 4” - 300#
Relief valve included MFR#
Container Flange connection
21/2”
UL rating
asme rating
27,750 (3)
N/A
Not Applicable
27,400
Outlet 31/2-*N (F) thread, will accept 3” M. NPT pipe thread.
A3149G
Gas Equipment Catalog
webb# 162576 162577 251121 251122
victormfg.com
SECTION
2
Pressure Relief Valves & Relief Valve Manifolds Multiport® Pressure Relief Valve Assemblies for Large Storage Containers (continued) MFR#
consists of
for use with
for connection to
7560-55
1-Bolt Stud and Nut
All RegO MultiportsTM
Modified 3” - 300# and 4” - ASA 300# Welding Neck Flange
webb# 186924
8
Manhold Cover Plate
189178
Flange Dimensions Manifold Sizes
flange size
flange drilling
port diameter
flange gasket
A8560
Modified 3” 300# (4” Port Dia.)
(8) 7/8” Bolt Holes on a 65/8” Bolt Circle Diameter Flat Faced.
4”
3” 7564-48
A8570 AA8570
4” ASA 300#
(8) 7/8” Bolt Holes on a 77/8” Bolt Circle Diameter 1/16” Raised Face.
4”
4” 7565-48
Flanged Internal Valves Gasket Mounting Information MFR# Description MFR#
Description
Webb#
7560-55
1 Nut and Stud
186924
7560-56
2 Nuts and Stud
189178
7560-58
3.50 Length
—
7560-60
1.13 Hex .64 Thk
—
Webb#
7565-48
7.00 O.D. 5.00 I.D. 0.13 Thk
273810
7884-30
7.00 O.D. 5.82 I.D. 0.18 Thk
186948
A7883-29
5.75 O.D. 4.75 I.D. 0.18 Thk
187055
A7883-30
8.75 O.D. 4.00 I.D. 0.13 Thk
187057
Victor/F.w. Webb has a “Trade-in” program for multiport pressure relief valves.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
43
2 valves & accessories
7560-56
Number required
SECTION
2
Globe & Angle Valves
“V”–Ring Seal Globe and Angle Valves for Bulk Storage Containers, Transports, Bobtails and Plant Piping Specifically designed to assure positive shut-off and long, maintenance-free service life in liquid or vapor service on bulk storage containers, transports, bobtails, cylinder filling plants and plant piping. The high quality construction and wide variety of sizes make them highly suited for use with LP-Gas, anhydrous ammonia and in the chemical and petrochemical industries. TA7034 A7505AP MFR#
Webb#
TA7034P
—
TA7034LP
189253
A7505AP
162539
A7506AP
162540
TA7505AP
187120
TA7506AP
—
A7507AP
162541
A7508AP
162542
TA7507AP
192877
A7509BP
162543
A7510BP
162544
GLOBE
ANGLE
GLOBE
ANGLE
inlet & Outlet connection
TA7509BP
193216
—
—
TA7034P
TA7034LP
1/2” F. NPT
TA7510BP
—
A7505AP A7506AP TA7505AP TA7506AP
3/4” F. NPT
A7511AP
162545
A7512AP
162546
TA7511AP
273830
TA7512AP
—
A7511FP
A7513AP A7514AP TA7513AP
—
A7513FP
A7513AP
A7513AP A7517FP
A7517AP flow at 1 psig pressure drop (cv) (gpm/ propane)***
MFR#
BUNA N SEAT DISCS
A7518FP
TEFLON SEAT DISCS* port diameter 3/4”
Globe
angle
10.00
14.8
12.0
17.7
1” F. NPT
1”
17.8
22.0
A7509BP A7510BP TA7509BP TA7510BP
11/4” F. NPT
11/4”
36.5
54.0
A7511AP A7512AP
11/2” F. NPT
43.0
55.5
46.0
—
A7507AP A7508AP TA7507AP
A7511FP
— A7514FP
—
TA7511AP
TA7512AP
—
—
TA7513FP
TA7614FP
11/2” Flange** 2” F. NPT 2” Flange**
11/2” 2”
75.0
88.5
78.0
133.0
197.0
303.0
accessories hydrostatic relief valve
vent valve
SS8001U #162490
TSS3169 #162450
162547
A7517AP A7518AP TA7517AP TA7518AP
A7514AP
162548
A7517FP
TA7513AP
190681
A7513FP
188570
* Teflon seat discs on valves built to order. ** 300# ANSI R.F. Flange *** To obtain approximate flow at other than 1 PSIG pressure drop, multiply flow in chart by square root of pressure drop.
A7514FP
162549
Flange Dimensions
TA7513FP
187124
A7517AP
162550
A7518AP
162551
TA7517AP
187126
TA7518AP
—
A7517FP
187041
A7518FP
162552
TA7517FP
44
189255
A7518FP
TA7517FP
—
3” F. NPT 3” Flange**
3”
Valve number
size
flange drilling
D
E
F
H
7511FP
11/2”
7/8” Bolt Holes on a 41/2” Bolt Circle Diameter
61/8”
13/16”
27/8”
3/4”
2”
3/4” Bolt Holes on a 5” Bolt Circle Diameter
61/2”
7/8”
35/8”
13/16”
7517FP
3”
7/8” Bolt Holes on a 65/8” Bolt Circle Diameter
81/4”
11/8”
5”
11/16”
7518FP
—
—
—
—
—
—
7513FP 7514FP
Reducing screwed flanges are available for reducing 11/2” flange or 1” or 11/2” pipe thread and 3” flanged to 21/2” pipe thread. Order from your local supplier.
Gas Equipment Catalog
victormfg.com
SECTION
2
Globe & Angle Valves Quick-Acting Minimum Loss Hose-End Valves for Bobtail Delivery Trucks and Dispensing Stations
A7797A
Locking Handle
Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane)
webb#
13/4”
Yes
16.0
187049
13/4”
Yes
16.0
162563
MFR#
Inlet Connection F. NPT
outlet connection f. Acme
A7793A
3/4”
A7797A
1”
Quick-Acting Hose-End Valves for Bobtail Delivery Trucks and Dispensing Stations
A7707L
Designed especially for safe operator handling of LP-Gas in bobtail delivery truck, dispensing systems and anhydrous ammonia nurse tank service. These valves provide instant, full-on flow at the flip of the handle and provide instant positive shut-off with a handle lock for added protection. accessories
MFR#
Body Design
A7707L
Globe
A7708L
Angle
inlet & outlet connection
locking handle
1”
Yes
Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane) 18.0 22.0
filling connectors extended
compact
Steel
brass
steel
webb#
A7575L4 #162711
3175A #162688
A3175A #162689
187048 162562
Flange Seal Globe and Angle Valves for Bulk Storage Containers, Filling Hoses and Plant Piping
A7704P
Designed to assure positive shut-off and long maintenance-free service life in liquid or vapor service. Ideally suited for use on cylinder charging manifolds, truck filling hoses, bulk storage containers and plant piping. The high quality construction and wide variety of sizes make them highly suited for use with LP-Gas, anhydrous ammonia and in the chemical and petrochemical industries. inlet & outlet connection F. NPT
Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane)
MFR#
body design
7704P
Globe
7.3
7704LP
Angle
12.3
A7704P
Globe
A7704LP
Angle
1/2”
Accessories hydrostatic relief valve
7.3 12.3
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Vent valve
webb# 162557
SS8001J or SS8001L
TSS3169
190689 162558 162559
45
2 valves & accessories
Designed to vastly reduce the amount of product vented when disconnecting bobtail trucks, dispensing systems and anhydrous ammonia nurse tanks. These valves provide instant, full-on-flow at the flip of a handle. Shut-off is instant and the handle locks for added protection. This “top of the line” hose-end valve is a fully contained unit that does not require additional filling adapters or connectors.
SECTION
2
Globe & Angle Valves
Flange Seal Globe and Angle Valves for Bulk Storage Containers, Filling Hoses and Plant Piping (continued)
A7706P
inlet & outlet connection F.NPT
Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane)
MFR#
body design
7705P
Globe
11.5
7706P
Angle
17.7
A7705P
Globe
A7706P
Angle
3/4”
Accessories hydrostatic relief valve
Vent valve
webb# 163076
SS8001J or SS8001L
11.5
TSS3169
17.7
163077 162560 162561
Flange Seal Liquid Transfer Angle Valves for Bulk Storage Containers
7550P
MFR#
inlet & outlet connection M. NPT
Designed especially for liquid transfer of LP-Gas from consumer bulk storage containers when used with a Chek-Lok® or equipped with an integral excess flow valve. May also be used for vapor LP-Gas service. In NH3 applicator tanks they may be used as a vapor bleeder valve or as a liquid withdrawal valve when installed in a coupling with a dip pipe. These liquid transfer valves are equipped with an integral excess flow valve for liquid transfer directly from the tank fitting, or without an integral excess flow for LP Gas transfer through a Check-Lok®. When equipped with an integral excess flow valve (7550PX), the valve should be mounted in a forged steel 3000 lb. half coupling. When mounted in a 11/4” X 3/4” NPT reducing coupling, the 3/4” female thread in this coupling must be full length — equivalent to a forged steel 3000 lb. half coupling. The excess flow valve will not function properly if these specifications are not met.
outlet connection F. NPT
7550P
No
A7550P 7550PX A7550PX 7551P A7551P
46
Flow at 1 PSIG (CV) integral Pressure excess Drop flow (GPM/Propane) 13.3
accessories Excess Flow HydroApproximate static closing flow Relief (GPM/Propane) valve —
3/4” 3/4”
Yes 1/2”
No
Gas Equipment Catalog
— 8.9
16.0 —
vent valve
webb#
3127U
3165
162760
SS8001J
TSS3169
162474
3127U
3165
162476
SS8001J
TSS3169
162475
3127U
3165
266448
SS8001J
TSS3169
273806
victormfg.com
SECTION
2
Globe & Angle Valves Quick-Acting Valves for Cylinder Charging Hoses Designed primarily for use on cylinder charging hoses to provide fast, convenient shut-off and fast opening. These valves must be installed so that flow through the valve is in the opposite direction to that of a conventional globe valve. This allows the inlet flow to assist in closing the valve, even more important, helps prevent the valve from being forced open by high pump pressure.
MFR#
outlet connection f. NPT
BODY MATERIAL
A7553A
1/4”
1/4”
Ductile Iron
7901TA
3/8”
3/8”
7901TB 7901TC
1/4”
1/2”
Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane)
webb# 189220
1.95
Brass
1/2”
162487 162488 162489
Quick-Acting Valves for Crop Driers and Charging Manifold Hoses
7554S
7554S Series valves provide instant shut-off and fast opening control on LP-Gas crop driers. They are ideal for charging manifold hoses, stationary fuel transfer hoses and other applications requiring quick, positive shut-off. They are not for use with delivery truck hoses because the handle could snag on the ground and open the valve as the hose is needed back to the truck 7554L Series valves feature a locking handle device to help prevent accidental opening of the valve. It is ideal for all the same applications as the 7554S Series and may be used on delivery trucks as it incorporates the locking handle design. Both valve series must be installed so that flow through the valve is opposite to that of a conventional globe valve. This allows the inlet flow to assist in closing the valve and prevents the valve from being opened by high pump pressures.
MFR# 7554SAV 7554LAV 7554SV 7554LV
Inlet & Outlet Connection F. NPT 1/2”
3/4”
Locking Handle
Flow at 1 PSIG (CV) Pressure Drop (GPM/Propane)
No Yes No Yes
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
7.3 11.5
webb# 186921 186920 162555 162553
47
valves & accessories
7901TA
Inlet Connection F. NPT
2
SECTION
2
Globe & Angle Valves
Multipurpose Valves for Liquid Withdrawal of LP-Gas and NH3 Containers Designed especially for use as a high capacity liquid withdrawal valve on LP-Gas and anhydrous ammonia containers. The A8017DH is equipped with a soft seated automatic differential back pressure check valve in the seat disc assembly. This allows any pressure build up in the liquid transfer line in excess of 10-15 psig above the container pressure to flow back into the container. The transfer hose is protected against excessive liquid or vapor pressure entrapment, which adds materially to the useful life of flexible hose. In addition to increasing hose service life, the equalizing valve adds substantially to the operating safety of liquid transfer systems. Accessories
A8017DP MFR#
Excess Flow Inlet outlet Approximate Connection connection closing flow M. NPT f. NPT (GPM/Propane)
A8017DH A8017DP
11/4”
1”
A8017DLP
Hydrostatic relief valve
vent valve
49
Not Required
55
SS8001J
TSS3169
—
—
webb# 187075 162493
—
190679
Multipurpose Valve for Filling and Liquid Transfer of NH3 Containers Designed primarily for use as a combination filler and liquid withdrawal valve on threeopening applicator tanks or on nurse tanks. This valve incorporates an integral excess flow valve. When product is required, the valve must be completely open and backseated to allow the excess flow valve to function properly.
A8018DP
MFR# A8018DP
48
Inlet outlet Filling Connection connection Connection M. NPT f. NPT M. acme 11/4”
1”
13/4”
Gas Equipment Catalog
Filling capacity at 20 psig pressure drop gpm/ nh3
Excess Flow Approximate closing flow (GPM/nh3)
Hydrostatic relief valve
vent valve
webb#
74
50
SS8001J
TSS3169
187076
Accessories
victormfg.com
SECTION
2
Ball Valves Gas Ball Valves
For use on LP-Gas, flammable liquids, natural and mfg. gas, air, N2, inert gases, including helium and CO2. • 1/4” – 2” • Operable from -40°F to 300°F • UL listed
Model T/S-100 Webb# 184932 184933 151448 151449 163961 151450 151451 163962 — 151453 151454 151455 151456 151457 151458 151459 —
The new Jomar System-2 FIP to Flare, Flare to Flare and MIP to Flare valves are new products with vision. Equipped with all the features of the Blue-Cap®. • Raised wrench flats for installation ease. • It can be used in temperatures from -40°F to 300°F, making it ideal for outside use in extremely cold or warm climates. • The T-handle can be reversed into a locked position, by turning the handle to the off position, removing the tamper proof alien screw and reversing the handle 180° into the slot. • Each valve is shipped with plastic thread protectors to prevent leak causing nicks. • AGA and CGA design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/ air mixture. • AGA and CGA listed 0.5, 2 lb., 5 lb., System. Mfr# Desc. Model T-204 – FIP X FL JOM101-502 1/2” X 3/8” FIP X FL JOM101-503 1/2” FIP X FL Model T-204 – FL X FL JOM101-601 1/2” X 3/8” FL X FL JOM101-602 3/8” FL X FL JOM101-603 1/2” FL X FL JOM101-604 5/8” FL X FL Model T-204 – MIP X FL JOM101-702 1/2” X 3/8” MIP X FL JOM101-703 1/2” MIP X FL
Webb# 165040 58791 178937 184941 184942 184940 164856 164857
T-CS-2000 Series
Model T-204
Jomar’s T-2000 Series of steel valves are designed for rugged industrial applications of steam, water, oil, gas and corrosive materials. They are UL approved for LP-Gas, natural and manufactured gas, LP gas/air mixtures and anhydrousammonia. They feature solid ball construction, reinforced P.T.F.E. seats, two piece standard port design. Double viton o-rings prevent stem leakage. Special 2000 psi seats available upon request.
Jomar’s Blue Cap® II Manual Gas Valve, Model T-204 is American Gas Association Laboratories design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/air mixtures. The Blue Cap® II may be used as a 150lb. steam valve/600 W.O.G.
Mfr# JOM100-953 JOM100-954 JOM100-955 JOM100-956 JOM100-958
Desc. 1/2” SS 3/4” SS 1” SS 11/4” SS 2” SS
Webb# 184958 184951 184955 184956 184957
Locking Device 100-82-3LD Series • Type 2: Fits models T/S100, T-100UE, T/S100ST, T-100FB, T-100C and T-100SS, Size 3/4”. • Type 3: Fits models T/S100, T-100UE, T/S100ST, T-100FB, T-100C and T-100SS, Sizes 1” and 11/4”. Mfr# JOM210-995 JOM210-996
Desc. Webb# 3/4” Locking Device 111377 1 – 11/4” Locking Device —
Mfr# Desc. Model T-204 – FIP X FIP JOM101-401 1/4” FIP X FIP JOM101-402 3/8” FIP X FIP JOM101-403 1/2” FIP X FIP JOM101-404 3/4” FIP X FIP
Webb# 184937 184938 184939 184935
Models T-82 – Mini Valves Are designed for steam, water, oil or gas in commercial and light industrial use. The minivalves are competitive, conventional port, constructed of heavy duty forged brass, 100% Teflon seats and gland follower with double viton o-rings, to prevent stem leakage. Sells and installs cost wise as the leaky plug type, pet cock or gage cock without the leaks. Mfr# JOM100-297 JOM100-299 JOM100-300
Desc. 1/8” F X M 1/4” F X M 1/4” F X F
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Webb# 111346 111348 151225
49
2 valves & accessories
Mfr# Desc. Model T-100 Series JOM100-701 1/4” F. IPS JOM100-702 3/8” F. IPS JOM100-703 1/2” F. IPS JOM100-704 3/4” F. IPS JOM100-705 1” F. IPS JOM100-706 11/4” F. IPS JOM100-707 11/2” F. IPS JOM100-708 2” F. IPS JOM100-709 21/2” F. IPS JOM100-710 3” F. IPS Model S-100 Series JOM100-803 1/2” C X C JOM100-804 3/4” C X C JOM100-805 1” C X C JOM100-806 11/4” C X C JOM100-807 11/2” C X C JOM100-808 2” C X C JOM100-809 21/2” C X C
Models T-204
SECTION
2
Ball Valves Gas Ball Valves (continued) Model T-203 Equipped with all the features of the Blue-Cap®, the System-3 has additional features making it the best value on the valve market today. • A 1/8” NPT side tap allows a manometer to be inserted into the valve to test line pressure, eliminating the test tee and the labor to install it. • It can be used in temperatures down to -40°F to 300°F, making it ideal for outside use in extremely cold or warm climates. • The handle can be reversed into a locked position. Combined with the tamper proof screw, the possibility of unauthorized use is sharply reduced. • AGA and CGA design certified for use with natural, manufactured, mixed, liquified petroleum and LP gas/ air mixture. • UL Listings: LP-Gas, flammable liquids, natural and manufactured gas, air, N2, inert gases including helium and CO2. • The valve is rated 150 WSP/600 WOG. Remove the plug and you have a drainable ball valve for any fluid system.
T-2000N Series Carbon Steel Jomar’s T-2000N Series of steel valves are designed for rugged industrial applications of steam, water, oil, gas and corrosive materials. They are UL approved for LP-Gas, natural and manufactured gas, LP-Gas air mixtures and anhydrous–ammonia. They feature solid ball construction, 2nd generation P.T.F.E. seats, two piece standard port design. Double Viton O-Rings prevent stem leakage. Special 2000 PSI seats available upon request. • Conforms to federal specification WW-V-35. • Latch-Lock Feature: Valve comes complete with latch lock, which may be locked in open or closed position. • Pressure Rating: 2000 W.O.G.
Mfr# Desc. Webb# Model T-CS-2000N-SS JOM100-953 1/2” 184958 JOM100-954 3/4” 184951 JOM100-955 1” 184955 JOM100-956 11/4” 184956 JOM100-958 2” 184957
Dimension in Inches Mfr# Desc. Webb# Model T-203 – FIP X FIP JOM102-301 1/4” FEM Side Tap 178938 JOM102-302 3/8” FEM Side Tap 151303 JOM102-303 1/2” FEM Side Tap 151304 JOM102-304 3/4” FEM Side Tap 151305 JOM170-105 1” FEM Side Tap 178939 Model T-203 – FL X FL JOM102-402 3/8” FL Side Tap 151306 JOM102-403 1/2” FL Side Tap 151307 JOM102-404 5/8” FL Side Tap 151308 JOM102-405 1/2” FEM X FL Side Tap 167285
size a b c d
CV*
1/4”
2.07
0.37
1.76
4.33
6.8
3/8”
2.07
0.37
1.76
4.33
6.8
1/2”
2.34
0.50
1.92
4.33
9.8
3/4”
2.80
0.69
2.40
5.83
25
1”
3.23
0.87
2.56
5.83
35
11/4”
3.57
1.00
2.74
7.76
47
11/2”
4.04
1.25
2.98
7.76
81
2”
4.63
1.50
3.17
7.76
105
* The CV Factor is the gallons of water per minute passed through the valve with 1 PSI pressure drop.
50
Gas Equipment Catalog
victormfg.com
SECTION
2
Ball Valves Apollo Valves Made In The USA
Mfr# SIZE Webb# 70 Series With Tee-Handle APO7010307 1/2” 54031 54032 APO7010407 3/4” APO7010507 1” 54033 359 APO7010607 11/4” 360 APO7010707 11/2” APO7010807 2” 361
Mfr# SIZE Webb# 80 Series Lever Handle – UL Listed for Propane APO80103 1/2” 55189 3/4” 55190 APO80104 APO80105 1” 55191 55192 APO80106 11/4” 55193 APO80107 11/2” APO80108 2” 55194
valves & accessories
Lockable Valve for Meter
With tamper proof locking cover. s.80 NPT — 3/4” & 1”
• Special design. • Hot forged brass. • Pure Teflon® seats. • -40°F +350°F temperature. • Approved by AGA & CGA to ASME. B16.33 & AGA Req’t #3-88. • Full port to DIN 3357 for maximum flow. • Double seal system allows valve to be operated in either direction making installation easier. • Two Viton 0-rings at the stem for maximum safety. • No maintenance ever required. • 600 PSI non-shock cold working pressure.
cODE s80e41 s800f41 3/4” 1” D L 2.519 3.188 H 1.801 1.958
Mfr# description webb# 250084 S80E41 3/4” Lockable Valve S80F41 1” Lockable Valve 250085 378023 S80G41 11/4” Lockable Valve 378025 S80H41 11/2” Lockable Valve S80I41 2” Lockable Valve 378026
Rub Brass Locking Gas Shutoffs MFR#
80 Series
VCTS80E41 VCTS80F41 VCTS80G41 VCTS80H41 VCTS80I41 MFR#
8043 Series
VCTS80E43 VCTS80F43 VCTS80G43
Description
Webb#
3/4”
11/4” 11/2” 2”
250084 250085 378023 378025 378026
Description
Webb#
3/4” With Union
378021 378022 378024
1”
1” With Union 11/4” With Union
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
2
51
SECTION
2
Ball Valves
High Pressure Meter Valves — Plug Style
Safe Ball®
The Gas Stops Here! Model 175 LWN & Model 175 LWIN
• Gases: Natural or LP-Gases. • Service Designation: 175 PSIG. • Options: Test Tap at inlet, brass or painted finish. • 100% Leakage Testing: at 1.5 times service designation (263 PSIG); test methods meet or exceed D.O.T and ANSI B16.33. • ISO-EN 9002: Certified. • Threads Conform: To ANSI B1.20.1. • Warranty: 10 years against leakage under normal operating conditions.
Tamperproof • 175 PSIG Flat Head • Lockwing
560B Black Iron Body
560B Black Iron Body
3/4”, 1”, 11/4”, 11/2”, 2”
1/2”, 3/4”, 1”, 11/4”
MFR# dESC. WEBB# 184925 AYM560B-8 1/2”
MFR# dESC. WEBB# 184924 AYM560B-34 3/4”
High Pressure Meter Valves — Ball Style
Model 175 LWN
Model 175 LWiN
Tamperproof • 175 PSIG • Patented Flat Head • Lockwing
Mfr# Desc. Brass Locking Meter Valve With Union JOM241-004B 3/4” JOM241-005B 1”
Webb# 276314 —
Pressure Tap Optional
760B
Special Order
6276B MFR# dESC. WEBB# 216737 AYM6276B-34 3/4” AYM6276B-1 1” 216738 216739 AYM6276B-114 11/4”
Chicago Faucets Chicago Faucets multiple service valves enable the user to access virtually any laboratory gas. Solid brass construction with a high-gloss polished chrome finish and color coded handle index buttons. • Ball valve. • E7 – Removable serrated hose nozzle. • Air, gas and vacuum buttons. • 3/8” NPT male inlet thread. • 124 PSI or approximately 29.9” Hg vacuum. Mfr# Desc. Laboratory Gas Valve CFC909AGVCP 3/4” NPT Inlet
52
Webb# 117590
Gas Equipment Catalog
victormfg.com
SECTION
2
Excess Flow, Check, Filler, Vapor Equalizing Valves Excess Flow Valves for Liquid or Vapor Line Service Designed for top installation, in any position, in liquid or vapor service lines. They are intended for long lines or branch piping where tank mounted excess flow valves cannot suffice.
2
Approximate Closing Flows Body Material
MFR#
1519A2 A1519A2 1519A3 1519A4 A1519A6
Inlet Connection NPT
Outlet Connection F. NPT
Wrench Hex Flats
1”
1”
13/4”
11/2” 2” 3”
11/2” 2” 3”
21/4” 3” 4”
Brass Steel Brass Steel
Liquid (GPM Propane)
Vapor SCHF (Propane) 25 PSIG Inlet
100 PSIG Inlet
25
5,000
8,800
60 100 225
11,500 19,000 45,000
20,200 34,500 82,000
Webb#
162410 273805 275127 189125 —
Excess Flow Valves for Liquid or Vapor Designed for liquid or vapor use for filling, withdrawal and vapor equalizing in container or line applications. They are intended for long lines or branch piping where tank-mounted excess flow valves are inadequate.
3282C
MFR#
12472 3272E 3272F 3272G A3272G 3282A 3282C A3282C 7574 3292A A3292A 3292B A3292B A3292C
Body Material
Brass
A Inlet Connection NPT
3/4”
B Outlet Connection F. NPT
3/4”
C Wrench Hex Flats
1”
D Effective Length (Approx.)
1”
Steel Brass
11/4”
11/4”
2”
115/16”
11/2”
11/2”
21/4”
13/4”
Steel Brass Steel Brass Steel
2”
2”
2”
1”
Approximate Closing Flows* Vapor SCHF (Propane) Liquid (GPM Propane)
25 PSIG Inlet
100 PSIG Inlet
4 10 15
1,050 2,100 2,800
1,700 3,700 5,000
20
3,700
6,900
30
5,850
10,000
50
9,000
16,300
90
15,200
28,100
75
14,200
24,800
100
18,100
32,700
122
22,100
37,600
Webb#
186803 162452 162453 162584 162585 162586 186857 162587 162480 189148 — 162588 162589 162590
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
53
valves & accessories
A1519A6
Excess Flow, Check, Filler, Vapor Equalizing Valves
SECTION
2
Excess Flow Valves for Liquid or Vapor Service Designed for top mounting in storage tank manhole covers for liquid or vapor applications. The tapped inlet allows for an optional 1” NPT dip pipe connection to withdraw liquid from the top of the tank. The 1519C4 is designed for installation in long line or branch piping applications.
1519C4 Approximate Closing Flows MFR#
1519C4
Inlet Connection NPT
filling Connection F. NPT
Wrench Hex Flats
2” Female
2”
3”
Vapor SCHF (Propane) liquid (gpm propane)
25 PSIG Inlet
100 PSIG Inlet
170
28,590
48,600
Webb#
162411
NOTE: Multiply flow rate by .94 to determine liquid butane flow.
Excess Flow Valves for Container Service Designed for mounting in threaded full or half couplings in container installations. They may be used for filling, withdrawal or vapor equalizing applications. The exceptionally low pressure drop makes them ideal for pump suction lines. If a riser pipe to the vapor space is used with these valves, the minimum inside diameter of the riser must be at least two times the valve thread size in order not to restrict flow to the side inlet ports.
A7537N4F
MFR#
A8523 A7537L4F A7537N4 A7537N4F A7537P4 A7537P4F A7539R6F A7539T6 A7539T6F A7539V6 A7539V6F
For Use With This Type Coupling Half Full Half Full Half Full Full Half Full Half Full
Approximate Closing Flows* Inlet Connection M. NPT
Outlet Connection NPT
Wrench Hex Flats
3/4”
3/4” Male
1”
2”
2” Male and 11/4” Female
2”
3”
3” Male and 2” Female
33/4”
Liquid (GPM Propane)
Vapor SCHF (Propane) 25 PSIG Inlet
100 PSIG Inlet
15 75
5,170 13,000
8,800 25,600
125
25,000
42,500
150
30,500
52,000
150
32,100
55,500
200
39,400
68,300
250
51,100
88,700
Webb#
187082 — 189216 — 162594 162595 189217 187043 162473 275006 189219
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow.
54
Gas Equipment Catalog
victormfg.com
SECTION
2
Excess Flow, Check, Filler, Vapor Equalizing Valves Excess Flow Valves for Vapor or Liquid Designed especially for filling, withdrawing or vapor equalizing in half and full coupling installations. Ideal for container service where welded-in dip pipes are not provided. For vapor use, mount in the bottom opening with a threaded dip pipe. For liquid use, mount in the top opening with a threaded dip pipe. These may also be installed in pipe lines provided the connection is made to the male inlet thread and not the female dip pipe connection.
Approximate Closing Flows*** Inlet Connection NPT
Outlet Connection F. NPT
Wrench Hex Flats
A2137A
2”*
27/16”
2139 2139A
2” Male and 11/4” Female
3”**
3” Male and 2” Female
31/2”
MFR#
Liquid (GPM Propane)
Vapor SCHF (Propane)
Webb#
25 PSIG Inlet
100 PSIG Inlet
70
14,000
25,000
162415
125 160
26,500 32,700
46,000 57,200
— 308180
* 11/4” F. NPT Dip Pipe Connection ** 2” F. NPT Dip Pipe Connection *** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
Excess Flow Valves for Liquid or Vapor Withdrawal These valves are designed for bottom mounting in consumer storage tanks for liquid service. They may also be top mounted for vapor service. These valves are designed especially for use with RegO® globe and angle valves.
A8013D Approximate Closing Flows** MFR#
A8013D A8013DA 2723C
Inlet Connection NPT
11/4” 11/4”
Outlet Connection F. NPT* 3/4”
1” 3/4”
Wrench Hex Flats
1” 111/16”
Liquid (GPM Propane) 39 44 20
Vapor SCHF (Propane) 25 PSIG Inlet
100 PSIG Inlet
8,700
14,700
3,900
6,900
Webb#
187071 162491 162418
* 3/4” F. NPT Dip Pipe Connection ** Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
55
valves & accessories
A2137A
2
Excess Flow, Check, Filler, Vapor Equalizing Valves
SECTION
2
Excess Flow Valve for DOT Cylinders Designed for use on portable systems with vapor or liquid including torches, heaters, lead melting burners, tar and asphalt burners, wallpaper steamers and other applications involving portable DOT cylinders. The POL inlet attaches directly to the cylinder valve and the outlet mounts to the regulator. 3199W Approximate Closing Flows* MFR#
3199W
Inlet Connection NPT
Outlet Connection F. NPT
Wrench Hex Flats
Male POL
1/4”
7/8”
Vapor SCHF (Propane)
Liquid (GPM Propane) .95
25 PSIG Inlet
100 PSIG Inlet
265
500
Webb#
186856
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
Excess Flow Valve for Presssure Gauges Designed for container use in pressure gauge installations to minimize excess gas discharge in the event the pressure gauges is sheared. A suitable shut-off valve should be installed between this valve and the pressure gauge to allow convenient gauge replacement.
2884D Approximate Closing Flows* MFR#
Inlet Connection m. NPT
Outlet Connection F. NPT
Wrench Hex Flats
3/4”
1/4”
11/16”
2884D
Liquid (GPM Propane)
Vapor SCHF (Propane) 25 PSIG Inlet
100 PSIG Inlet
60
110
N/A
Webb#
186836
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
Excess Flow Valve for Flange Mounting in Container Service Designed for container use in pressure gauge installations to minimize excess gas discharge in the event the pressure gauges is sheared. A suitable shut-off valve should be installed between this valve and the pressure gauge to allow convenient gauge replacement.
A3500P4
MFR#
A3500P4
Approximate Closing Flows*
Inlet Connection NPT
For Installation
2”
Slotted Body
Liquid (GPM Propane) 150
Vapor SCHF (Propane) 25 PSIG Inlet
100 PSIG Inlet
30,500
52,000
Webb#
162591
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
56
Gas Equipment Catalog
victormfg.com
SECTION
2
Excess Flow, Check, Filler, Vapor Equalizing Valves 7590U and 7591U Check-Lok® Valves
7590U With Cap Inlet Connection
Outlet Connection
Body Wrench Hex Flats
Approximate Effective Length
Cap Wrench Hex Flats
Approximate Closing Flow, Liquid GPM (Propaine)*
3/4” M. NPT 11/4” M. NPT
1” UNF
1” 13/4”
17/16” 111/16”
15/16”
20 35
7590U 7591U 8594-1A 7590U-6 7590U-5A
Webb# 162748 204901 186981 372640 378311
Nylon Gasket O-Ring Brass Cap
* Based on horizontal installation of excess flow valve. Flows are slightly more when valves are installed with outlet up; slightly less when installed with outlet down. NOTE: Multiply flow rate by .94 to determine liquid butane flow and by .90 to determine liquid anhydrous ammonia flow.
Union Style Adapters for 7590U and 7591U The 7590U-10 adapter must be used to connect to the 7590U and 7591U Chek-Lok. This insures a proper connection to open the check mechanism. A built in nylon gasket provides a gas tight seal. 7590U—10 Union Style Adapter
MFR# 7590U-10
Inlet Connection
Outlet Connection
Wrench Hex Flats
Webb#
1” UNF
3/4” F. NPT
13/4”
162762
Check-Lok® Liquid Evacuation Adapter for 7590U and 7591U Valves Designed specifically for use with RegO® 7590U and 7591U Check-Lok® Excess Flow Valves. Adapter’s operating handle opens and closes equalizing stem in the Chek-Lok® valve. Eliminates gas flow through Check-Lok® valve when installing or removing adapter. Use of RegO® adapter ensures proper connections and opening of the check mechanism. 7590U-20 MFR# 7590U-20 8594-3A
Inlet Connection
Outlet Connection
A Wrench Hex Flats
B Approximate Length
15/8” F. UNF
3/4” F. NPT
13/4”
41/8”
Webb# 217164 189195
Plug
7572FC and 7580FC Check-Lok® Valves Design is the original Check-Lok. It has provided the LP-Gas industry with quality and dependable performance for over 35 years. These adapters must be used to connect to the 7572FC and 7580FC Check Loks to open the check mechanism properly. A built in nylon gasket provides a gas tight seal. 7572C-14A
7572C-15A
MFR# 7572C-14A 7572C-15A
Inlet Connection 3/4” M. NPT
Outlet Connection 3/4” F. NPT 3/4” M. NPT
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Wrench Hex Flats
Webb#
1”
162761 162478
57
2 valves & accessories
MFR#
Designed with unique 1” NPS threads on both Chek-Lok® outlet and adapter inlet. This helps prevent activation of the Chek-Lok® without use of the 7590U-10 adapter. Extra strength connection between body and adapter provides increased strength. An o-ring seal on adapter provides a gas tight seal before the adapter opens the equalizing stem. These Chek-Loks® are also designed for use on permanent installations provided the excess flow valve is sized properly for the system and piping. NOTE: In some cases, it may be necessary to use an in-line excess flow valve to protect the downstream piping. This valve is not recommended for use as a liquid source for pumps.
SECTION
2
Excess Flow, Check, Filler, Vapor Equalizing Valves Double Check Filler Valves
RegO® Double-Check Filler Valves incorporate a resilient upper check valve, normally designated as a filler valve, and a lower check valve, commonly called a back pressure check valve. Available in a range of sizes to cover virtually all LP-Gas storage containers, these valves are UL listed and meet NFPA standards, as well as other safety requirements. Flow of liquid into the storage container opens both check valves. When flow stops, they both are designed to close automatically to permit the operator to disconnect the hose coupling. The automatic closing action also helps prevent the discharge of container contents in the event of hose failure. The lower back pressure check affords extra protection by restricting the discharge if the upper check fails to function properly due to accidents or other causes. The double back check construction allows emergency inspection, repair, or replacement of the upper fill assembly without removing product from the container. When the upper filler valve body is removed, the lower back check valve provides a seal, permitting only some leakage, allowing a new upper filler valve body to be installed.
Flat Gaskets Buna-N MFR# A2797-20R A2697-20R A3184-8R A3194-8R
ACME
quantity
Webb#
11/4” 13/4” 21/4” 31/4”
25 Pack 25 Pack 20 Pack 10 Pack
187010 187009 187015 162538
Double Check Filler Valves for Forklift, Motor Fuel and RV Tanks Designed to provide fast filling of forklift, motor fuel, and recreational vehicle tanks.
7647SC
MFR#
(With Lanyard & Cap)
A Hose Connection
B Tank Connection M. NPT
C Wrench Flats
D Effective Length
13/4” ACME
3/4”
11/2” 13/4”
31/16” 21/4”*
7647SA** 7647SC*
(Approx.)
Propane Liquid Capacity at Various Differential Pressures (GPM)*** 10 20 30 40 50 PSIG PSIG PSIG PSIG PSIG 14
20
24
27
50
Webb#
190841 162756
* Larger 13/4” hex wrench flats. ** 30º angle on 11/4” ACME hose connection. *** Multiply flow rate by .94 to determine liquid butane capacity.
Double-Check Filler Valves for Large Motor Fuel and ASME Tanks 7579 6579 MFR# Cap Only
Cap, Chain and Ring
7579 7579P* 6579**
7579C — 6579C**
Designed to provide fast filling of large motor fuel and ASME domestic tanks. The 6579 Series incorporates a swing-away lower check which greatly reduces pressure drop across the valve. This lower pressure drop promotes faster filling rates and greater efficiency resulting in more profitable operations.
ACME Hose Connection
Tank Connection M. NPT
Wrench Hex Flats
13/4”
11/4”
1”
Propane Liquid Capacity at Various Differential Pressures (GPM) 5 PSIG
10 PSIG
25 PSIG
50 PSIG
75 PSIG
50 37 78
70 52 110
111 82 174
157 116 246
192 142 301
Webb#
162745 189180 162467
* Incorporates 3/4 F. NPT dip pipe connection. **Swing-away lower back check valve design for higher filling rate. NOTE: Multiply flow rate by .94 to determine liquid butane capacity.
58
Gas Equipment Catalog
victormfg.com
SECTION
2
Excess Flow, Check, Filler, Vapor Equalizing Valves Double Check Vapor Equalizing Valves for ASME and DOT Containers Designed to facilitate loading operations by providing equalization of pressures in the supply and storage containers. The supplementary excess flow valve closes when the flow from the container being filled exceeds a predetermined rate. The 7573 Series is designed for use in bulk delivery systems and motor fuel containers. The 3183AC is designed for use in delivery trucks and other large containers.
7573DC
Basic
With Chain & Cap
7573D —
7573DC 3183AC
ACME Tank Hose Connection Connection M. NPT 11/4” 13/4”
Wrench Hex Flats
3/4” 11/4”
Approx. Closing Flow at 100 PSIG Inlet Webb# Pressure (SCFH/Propane)
11/4” 2
4,100 10,000
162744 250112
Double Check Filler Valves for Delivery Truck Tanks and Large Storage Designed to provide fast filling of bobtails, transports and large bulk storage tanks. The 6587CD incorporates a swing-away lower check which greatly reduces pressure drop across the valve. This lower pressure drop promotes faster filling rates and greater efficiency resulting in more profitable operations.
7579S
MFR#
ACME Hose Connection
Tank Connection M. NPT
Wrench Hex Flats
7579S
13/4”
11/2”
2”
Propane Liquid Capacity at Various Differential Pressures (GPM) 5 PSIG
10 PSIG
25 PSIG
50 PSIG
75 PSIG
44
62
98
139
170
Webb#
162481
Back Pressure Valves for Container or Line Applications Designed to provide protection of a container opening when desired flow is always into the vessel. May be used in line applications where flow must be limited to one direction. When used with the appropriate single check fill valve, the combination forms a double check filler valve suitable for use in filling of bulk storage tanks.
3146 MFR# Brass
Steel
3146 — 3176 — — —
— A3146 — A3176 A3186 A3196
Propane Liquid Capacity at Various Differential Pressures (GPM)
A Inlet Connection F. NPT
B Outlet Connection M. NPT
C Wrench Hex Flats
D Effective length (approx.)
5 PSIG
10 PSIG
25 PSIG
50 PSIG
3/4”
3/4”
13/8”
115/16”
11
16
25
36
11/4”
11/4”
2”
13/8”
28
40
63
89
2” 3”
2” 3”
27/8” 4”
27/16” 315/16”
124 297
175 420
276 664
391 939
Webb#
162578 187012 162580 162581 162582 162583
Back Pressure Check Valves RegO® Back Pressure Check Valves are designed to allow flow in one direction only. The check, normally held in the closed position by a spring, precludes the possibility of flow out of the container. When flow starts into the container, the pressure overcomes the force of the spring to open the check. When the flow stops or reverses, the check closes. TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
59
valves & accessories
MFR#
2
Excess Flow, Check, Filler, Vapor Equalizing Valves
SECTION
2
Single Check Filler Valves for Storage with Supplementary Back Check Valves Designed for use with RegO® Back Check Valves to provide fast filling of bulk storage tanks. Also may be used as a spare or replacement part. These single check filler valves must never be installed directly into container couplings. They must be used with the appropriate back check valve to comply with NFPA Pamphlet #58. 3174C
MFR#
ACME Hose Connection
Outlet Connection M. NPT
Wrench Hex Flats
13/4” 31/4”
11/4” 3”
13/4” 31/2”
3174C 3194C
Propane Liquid Capacity at Various Differential Pressures (GPM) 5 PSIG
10 PSIG
25 PSIG
50 PSIG
23 147
33 208
52 329
74 465
For Use With Back Check Valve
Webb#
3176 A3196
189144 189146
Vapor Equalizing Valves RegO® Vapor Equalizing Valves consist of an upper back check valve and lower excess flow valve. In the closed position, the attachment of a vapor hose coupling with its projecting nozzle, opens the back check valve to permit flow in either direction. The lower excess flow valve is designed to close automatically when flow out of the container being filled exceeds the rated capacity. The valve closes automatically when the coupling is removed. Like the double-check filler valves, the vapor equalizing valves utilize a two-piece body construction. The lower excess flow valve will permit some leakage when the upper back check valve is removed for emergency repairs or replacement. RegO® Vapor Equalizing Valves are designed for use in both ASME and DOT containers.
Flat Gaskets Buna-N MFR# A2797-20R A2697-20R
ACME
quantity
Webb#
11/4” 13/4”
25 Pack 25 Pack
187010 187009
Single Check Vapor Equalizing Valves for ASME and DOT Containers with Supplementary Excess Flow Valves
3170
MFR# Basic
With Chain & Cap
3170 -—
— 3180C
60
Designed for use with RegO® Excess Flow Valves to facilitate loading operations by providing equalization of pressures in the supply and storage containers. Also may be used as a spare or replacement part. These vapor equalizing valves must never be installed directly into container couplings. They must be used with the appropriate excess flow valve to comply with NFPA Pamphlet #58.
Inlet Connection
Outlet Connection
Wrench Hex Flats
Approx. Closing Flow at 100 PSIG Inlet Pressure
11/4” 13/4”
3/4” 11/4”
11/4” 13/4”
7,600 10,000
Gas Equipment Catalog
Webb#
(SCFH/Propane Vapor) 189142 189145
victormfg.com
SECTION
2
Excess Flow, Check, Filler, Vapor Equalizing Valves Bronze Swing Check Valves Class 300 — Y-Pattern — Threaded Ends
Features: • Screwed Cap. • Always install with pressure under the disc in vertical or horizontal position. An arrow cast on the body indicates the correct direction of flow. • MSS-SP-60. Type 3. Working Pressures Non-Shock: 300 psi Steam, Basic Rating. 1000 psi Cold Working Pressure – 1/4” to 2” (6mm – 50mm). 600 psi Cold Working Pressure – 21/2” to 3” (65mm – 80mm).
valves & accessories
Swing Check Valve
2
mfr# webb# CRV76E-38
6143
CRV76E-12
6144
CRV76E-34
6145
CRV76E-1
6146
CRV76E-114
6147
CRV76E-112
6148
CRV76E-2
6149
Bronze Lift Check Valves Class 300 — Threaded Ends
Features: • MSS-SP-80, Type 1. Suggested to be used on a compressor or similar application with constant pulsating supply. Must be installed horizontally only. Working Pressure Non-Shock: 300 psi Steam, Basic Rating. 1000 psi Cold Working Pressure.
Lift Check Valve
mfr# size webb# CRV366E-34
1/4”
—
CRV366E-1
1”
—
CRV366E-114 11/4”
—
CRV366E-112 11/2”
—
CRV366E-2
2”
6159
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
61
SECTION
2
Internal Valves & Accessories
11/4” Threaded Internal Valve for Small Capacity Pumping Systems and Bobtail Vapor Equalization Designed primarily for use with LP-Gas and anhydrous ammonia as a main valve on small capacity pumping systems, NH3 nurse tanks and in-line installations. It may also be installed in the vapor equalizing opening on bobtail delivery trucks. Installation is quick and easy, and it fits in both full and half couplings, as well as, in-line applications. The valve may be activated manually by hand or cable. A3209D050
MFR# A3209D050 A3209D080
Inlet Connection M. NPT
Outlet Connection F. NPT
11/4” 11/4”
11/4” 11/4”
Closing Flow (GPM) LP Gas 50 80
LP Gas Vapor Capacity SCFH/Propane
Accessories
NH3
25 PSIG Inlet
100 PSIG Inlet
Thermal Latch
Pneumatic Actuator
45 72
13300 15700
22900 26700
A3209TL A3209TL
A3209PA A3209PA
Webb#
251120 251118
Flomatic® Internal Valves for Bobtail Delivery Trucks, Transports and Large Stationary Storage Tanks A7883FK MFR# A7883FK A7884FK
62
Designed primarily for LP-Gas and anhydrous ammonia liquid withdrawal on MC331 bobtail delivery trucks, transports and large stationary storage containers with flanged connections. The valve is fully automatic, opening and closing as the pump is turned on or off.
Inlet Connection ANSI Flange
Outlet Connection ANSI Flange
Strainer Width
Base Width
Overall Height (Approx.)
Height from Indicator to Base
Filter
3-Way Valve
3” - 300# 4” - 300#
3” - 300# 4” - 300#
43/4” 53/4”
81/4” 10”
107/8” 111/4”
413/16” 415/16”
A7884201
A7853A
Gas Equipment Catalog
Accessories
Webb# 162571 193215
victormfg.com
SECTION
2
Internal Valves & Accessories Threaded Internal Valves for Bobtail Delivery Trucks, Transports and Stationary Storage Tanks Designed primarily for use with LP-Gas and anhydrous ammonia for liquid withdrawal; vapor transfer or vapor equalization of bobtail delivery trucks, transports, stationary storage tanks, and in-line installations. The valve may be operated manually by cable or pneumatically.
A3212R105
A3212R105 A3212R250 A3212R250-115 A3213R150 A3213R300 A3213R400
Inlet Connection M. NPT
Outlet Connection F. NPT
2”
2”
3”
3”
Closing Flow (GPM) Full Coupling MFR#
A3212R105 A3212R250 A3212R250-115 A3213R150 A3213R300 A3213R400
LP Gas
NH3
65 130 — 125 250 325
59 117 — 113 225 293
Closing Flow (GPM) Half Coupling LP Gas
NH3
105 250 — 150 300 400
95 225 — 135 270 360
Accessories Thermal Latch
Pneumatic Actuator
rotary pneumatic actuator
A3212TL #189207
A3213PA #162570
A3212RA
—
—
A3213TL #189208
A3213PA #162570
A3213RA
Webb#
189206 187019 — 190677 187020 162569
T Series MFR# A3212RT250 A3213T300 A3213T400
Inlet Connection M. NPT
Outlet Connection F. NPT
2”
2”
3”
3”
Closing Flow (GPM) Half Coupling LP Gas
NH3
250 300 400
— — —
Webb# 273831 224357 251119
ESV Pneumatic Controls MFR# 7781AFPN-1 6016-60D 7605PN-50
7605PN-50
7605APN-8A 7605A-BT 7605AP-16 7605AP-15 7605AP-12 P/HPPB430500 P/HA4MC4MG P/HA4TU4MG P/HA4UC4MG
Description
Webb#
Cylinder assembly kit to convert 7781AF ESVs to pneumatic shutdown. Cylinder assembly kit to convert 6016 ESVs to pneumatic shutdown. Pneumatic remote shutdown system kit, complete with 100’ of tubing, fittings, 1 charging valve assembly and 1 remote shutdown valve assembly. Extra shutdown valve assembly. 100’ roll of 1/4” pneumatic tubing. 1/4” tubing tee, with nuts. 1/8” NPT x 1/4” tubing, straight connector. Charging Valve Assembly 1/4” tubing (per foot) 1/4” NPT x 1/4” tubing, stright connector 1/4” tubing tee with nuts 1/4” tubing union
241753 359336
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
189185 246564 189182 186935 186934 266444 228691 228953 228973 228974
63
valves & accessories
MFR#
2
SECTION
2
Adapters, Connectors & Fittings Short Type Hose Couplings for Vapor and Liquid Service
Style A For Liquid Filling
Style C For Vapor Equalizing
MFR#
Material
3175B 3175 3175A 3185
Brass
3195
Style B For Liquid Filling
Style D For Vapor Equalizing
A3175 A3175A A3185 A3195 3171A 3181 3181A 3191
Style A
Brass Nut and Steel Nipple
B
Hose Connection M. NPT 1/2” 3/4” 1” 11/4”
Coupling Connection F. ACME
2”
31/4” 13/4”
1”
11/4” 2” 1/2“ 3/4” 1” 11/4”
B C
Brass
21/4”
3/4”
A
Steel
13/4”
D
MFR#
Tailpiece Bore
3175B 3175 3175A 3185 3195 A3175 A3175A A3185 A3195 3171A 3181 3181A 3191
35/64”
21/4” 31/4” 11/4” 13/4” 21/4”
Hose End To Nut
Overall Length
2”
2”
13/16” 113/16”
21/16” 2”
3” 3”
3/4”
2”
2”
13/16” 113/16” 17/32” 11/16” 15/16” 3/16”
2” 2’
3” 3”
13/16” 2” 1” 2”
27/16” 31/4” 3” 35/16”
3/4”
Webb# 186853 162687 162688 186854 162692 257541 162689 187016 162693 162686 162690 162691 186855
ACME Check Connectors for Lift Trucks
7141M
7141F
These brass connectors are especially designed to join the carburetor fuel line to the service valve on lift truck cylinders. Sturdy, long lasting ACME threads allow quick, hand-tight assembly that provides for quick and simple cylinder replacement. Back checks automatically close in each connector when disconnected. The 7141M couples directly to the service valve. An integral O-ring is designed to seal before the internal check opens, aiding in product loss prevention. A gasket at the ACME thread is a secondary seal when the connectors are tightened together. The connector fits RegO® lift truck cylinder filling adapters for fast, convenient filling. The 7141F accepts fuel line adapter and couples directly to the 7141M. The O-ring seal in the 7141M is designed to seal before the internal check opens to allow product to pass through the connection. The knurled coupling eases threading and the ACME threads provide rapid effortless make-up, even against LP-Gas pressure.
MFR#
Application
Inlet
Outlet
7141M 7141F
Service Valve Fuel Line
3/8” F. NPT 11/4” F. ACME
11/4” M. ACME 1/4” F. NPT
Protective Cap* Rubber
Brass
7141M-40 —
7141FP —
Webb# 162755 162754
* Recommended to minimize foreign material entering valves which could result in leakage.
64
Gas Equipment Catalog
victormfg.com
SECTION
2
Adapters, Connectors & Fittings Unloading Adapters for Container Evacuation Designed to provide an efficient means of evacuating an LP-Gas container for relocation or repair. They thread directly onto the 13/4” ACME male hose connection of RegO® Filler Valves used on RegO® Double Check Filler Valves and Multivalves®. The unloading adapters can be used to withdraw liquid provided the container is equipped with a dip pipe extending from the filler valve to the bottom of the container. Style
3119A 3120 3121
In-Line
A Filler Valve Connection
B Hose Connection
Webb#
13/4” F. ACME
162830 162831 263104
13/4” F. ACME
Angle
3/4” F. NPT
3120
Extended Type Hose Couplings for Vapor and Liquid Service
3121
A7575L
Designed especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited travel of the handle on the tailpiece minimizes spin-off, encouraging cautious removal to properly bleed off trapped product to assure closure of the filler valve and hose end valve. The ACME threads are machined on a rugged steel insert which is permanently cast in the aluminum handle, providing for durability under repeated use. MFR# A7575L2* A7575L3 A7575L4 A7571LB
Type of Service
Hose Connection M. NPT
Coupling Connection F. ACME
Approx. Length
Webb#
7”
275141 162710 162711 189221
1/2”
Liquid
3/4”
13/4”
1” Vapor
3/4”
11/4”
* Includes 7199-33 adapter, shipped loose.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
65
valves & accessories
3119A
MFR#
2
SECTION
2
Adapters, Connectors & Fittings Filler Hose Adapters
These adapters are designed with minimal flow restriction and recommended for use on the outlet of the LP-Gas delivery truck filler hose. If the controlled bleed off of the connection indicates the filler valve on the tank being filled has failed to close, the hose adapter should be left in place on the filler valve and disconnection should be made at the regular filler hose coupling. (Repair of the filler valve must be made as soon as possible). An integral check valve in these adapters helps prevent further loss of product. The standard filler valve cap should be attached to these adapters when left on the container.
3179B 7577V
MFR#
Built-In Vent Valve
Filler Valve Connection
Hose Connection
Propane Liquid Capacity at 80 PSID
Webb#
7577V 3179B 7576
Yes No Yes
13/4” F. ACME
13/4” M. ACME
57 GPM
162764 162763 —
ACME Adapters MFR#
Gasket (Furnished with adapter)
ACME X Female NPT
Material
A M. ACME
Brass
A5764D
Steel
13/4”
MFR#
Material
ACME X Male NPT
5765D 5765E 5767F 5767G 5767H 5769H 5769K A5765C A5765D A5765E A5765F
D
E Diameter
13/4”
1/2”
13/4”
3/4”
1” 1”
For Spare Gasket order MFR#
11/2”
3/8”
1”
3/4”
a269720r
187009
21/4”
25/16”
1”
A31848R
187015
31/2”
3”
2”
A31948R
162538
1”
13/4”
23/16”
3/4”
a269720r
187009
A M. ACME
B M. NPT
C Hex
D
E Diameter
11/4”
3/4”
11/4”
13/4”
7/16”
13/4”
1” 2”
11/16”
21/4”
25/16”
2” 3” 31/2”
27/16” 2” 3”
13/4”
23/16”
31/4”
2”
21/4” 31/4”
13/4” Brass
21/4” 31/4”
Steel
A5769H
66
C Hex
1/4”
5764A 5764B 5764C 5764D 5764E 5766E 5766F 5768G 5768H
5763D Gasket (Furnished with adapter)
B F. NPT
Gas Equipment Catalog
13/4”
31/4”
11/4” 11/2” 2”
3/4”
1” 11/4” 11/2” 2” 2” 3” 1/2” 3/4” 1” 11/4” 2”
3/4” 13/16” 1” 125/64” 1” 2” 17/32” 11/16” 7/8” 15/16”
1”
Webb# 162464 186865 162465 186866 162698 162704 186868 194502 162705 189210
For Spare Gasket Webb# order MFR# A2797- 187010 189153 20r A2697- 187009 186867 20R 162700 189154 A3184- 187015 189155 8R 189156 A3194- 162538 162706 8R 189158 — a2697- 187009 189211 20r 162701 189212 A3194- 187015 162707 8R
victormfg.com
SECTION
2
Adapters, Connectors & Fittings ACME Adapters MFR#
Material
A M. ACME
B M. ACME
C Hex
D Diameter
13/4”
13/4”
21/16”
—
21/4”
21/4“
25/16”
125/64”
31/4”
1/2”
23/4”
2”
5765M 5767M
(continued)
Brass
5769M
Webb# 162703 189157 162708
MFR#
Material
A M. ACME
B F. NPT
C Hex
D Diameter
Webb#
A5764W
Steel
13/4”
—
11/4”
111/16”
162699
ACME Plugs (CGA 510) POL
970 Hard Nose POL
Specifically designed to withstand the everyday abuse given hose end valves on delivery trucks and hose end couplings on risers in bulk plants. These rugged plugs protect the coupling tip as well as prevent the entrance of dirt, dust, snow and rain. They also prevent possible gas contamination from these same sources. The heavily ribbed outer surface permits hand-tight make-up. MFR#
(CGA 510) POL
970HT Soft Nose POL With Handwheel
Material
C5762N C5765N 5765PR C5767N C5769N
M. ACME
Chain & Ring Fits Pipe Size Up to:
Webb#
3/4” 11/4” — 11/4” 2”
162463 162466 250302 187102 162709
11/4”
Nylon
13/4”
Brass
21/4” 31/4”
Nylon
POL Plugs Highly recommended for installation in LP-Gas cylinder valve POL outlets whenever the service line is disconnected or when the cylinder is being transported. When properly installed, the POL plug is designed to prevent contamination of the valve outlet and guards against product leakage if the cylinder valve is accidentally opened. n970p
MFR#
Material
N970P 10538P 3705RC
Cycolac Brass
Connection
Webb#
M. POL CGA 510
179491 189118 162456
Male POL Swivel Adapters (CGA 510) POL
970AX Hard Nose POL With Excess Flow
50-70 Micron Filter
3199W Heavy Duty Hard Nose POL With Excess Flow
MFR# 970 970S 970AX 970AXS 3199W 970AW 970HT 970JR
Material M. A NPT
B C Hex Drill 5/16” 3/16”
1/4”
Brass
—
M. NPT
1/4” Hose Barb
5/16”
1” —
3”
—
5/32”
D
Vapor at 100 PSIG Inlet (SCFH)
2” 23/32”
—
—
25/64”
404
1.10
27/16”
450
0.95
—
—
Liquid Webb# (GPM)
21/16” 2”
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
2
191818 162771 187003 246565 186856 187002 243117 190842
67
valves & accessories
For Spare Gasket Order MFR# a2697-20r #187009 A3184-8R #187015 A3194-8R #162538
SECTION
2
Adapters, Connectors & Fittings POL Adapters
(CGA 510) POL
2906G Male POL X Female NPT
MFR#
Material
2906A 2906G
Brass
MFR#
A M. ACME 1/4” 1/2”
1” 2”
Material
A
B
Brass
3/8” M. NPT 3/8” SAE Flare 1/2” SAE Flare
2906D 2906F 2906E MFR#
(CGA 510) POL
5760A 5760B 5760C 5760D
Male POL X Male NPT and SAE Flare
Material
MFR#
Female POL X Female NPT and Female POL
(CGA 510) POL
Female POL X Male NPT
D Diameter
Webb#
1/4”
189131 162828
C Hex
D Diameter
Webb#
15/16”
11/32”
189132
7/8”
9/32”
C Hex
D Diameter
15/16”
1”
11/16” 21/4”
A
B
1/4”
15/8”
11/8”
17/8”
13/8”
POL CGA 510
21/8”
11/8”
A
B
C Hex
13/32”
163431
D Diameter
1/4”
3/16”
3/8”
13/32”
Webb# 162457 162458 162459 162460
43/64”
3/4”
Material
162826
35/64”
1/2”
Brass
162827
13/32”
3/8”
5760S
(CGA 510) POL
C Hex
B
Webb#
5761A 5761B 5761C 5761D
Brass
MFR#
Material
A
B
C
Webb#
1494-1
Brass
12” F. NPT
1/4” F. NPT
1/2” M. NPT
162823
15/8”
1/2”
11/8”
186863 186864 162461 162462
7/16”
3/4”
Excess Flow Adapters MFR# 3188B 3188C
3188 Heavy Duty Hard Nose POL With Excess Flow
Material M. A NPT Brass
B C Hex Drill
1/2” M. NPT
1”
5/16”
D
Vapor at 100 PSIG Inlet (SCFH)
21/2”
700 1180
Liquid Webb# (GPM) 1.9 2.9
246615 246616
Miscellaneous Adapters MFR#
Material
A
B
Webb#
15774-1
Brass
1/4” M. NPT
Female Inverted Flare
162501
Test Adapters MFR# 1328 1331 1332
68
Material Brass
A
B
5/8” - 18 UNF
5/8” - 18 UNF
3/4” - 16 UNF
3/4” - 16 UNF
7/8” - 14 UNF
7/8” - 14 UNF
Gas Equipment Catalog
C HEX 1/2”
Hose Barb
D
E
F
Webb#
13/16”
2” 21/8” 21/2”
11/2”
162816 162817 162818
15/16”
11/16”
13/4”
victormfg.com
SECTION
7141FP Cap Plug
2
Miscellaneous Equipment A5776
3175P Cap Plug
Cap and Reducers
3144-91 Plastic Cap MFR#
Chain & Ring fits pipe size up to:
Cap only MFR#
Material
3144-91
3/4"
3144-9P 224434
Cycolac
1 1/4" F Acme
186849
7141FP Cap Plug
1 3/4" F Acme
907FP 189143
Nylon
F POL CGA510
189128
1 1/4" F Acme
189166
A5776 3174-9P 162832 Reducer Coupling
3174-91 3174-93 3175P
1 1/4"
Cap1708C Plug
3/4"
7141FP
A8016-9P 275116
1 1/4"
Thread Connection
Brass
1 3/4" F Acme
3175P Cap Plug
3184-90
2"
3194-90
3"
A3184-90
2"
A3194-90
3"
A5776 Reducer Coupling
7141FP A8016-9P 275116 Cap Plug 5774
2 1/4" F Acme
Steel
162694
3 1/4" F Acme
162695
1 3/4" M Acme x 3 1/4" F Acme
187024
1708 POL Cap
3144-90 Metal Cap 1708 POL Cap
3144-90 Metal Cap
3194-90G ACME Cap With Stainless Steel Flange
1708 POL Cap
CGA 555 Swivel Adapters MFR#
Material
A
B Hex
C Drill
D
Webb#
12982
Brass
1/4” M. NPT
11/4”
3/16”
115/16”
190684
1708 POL Cap
1708 POL Cap
162695
2 1/4" F Acme
3194-90G ACME Cap With Stainless Steel Flange
907FP
3144-90 Metal Cap
3 1/4" F Acme
907FP
7141FP Cap Plug
907FP
162694
2 1/4" M Acme x 3 1/4" F Acme
907FP
3144-90 Metal Cap
7141FP Cap Plug
192871
3144-90
1 3/4" M Acme x 3 1/4" F Acme 261759 Metal Cap
A5776
A5776 Reducer Coupling
2
162451
3175P 5776
Webb#
valves & accessories
3144-91 Plastic Cap
Reducer Coupling
3194-90G ACME Cap With Stainless Steel Flange
3194-90G ACME Cap With Stainless Steel Flange
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
69
SECTION
2
Miscellaneous Equipment 1” Rotogages for Large Mobile and Stationary Containers ®
Rotogages® are designed to provide an accurate determination of LP-Gas or anhydrous ammonia container contents. They mount in a standard 1” NPT coupling on large mobile or stationary containers. To operate the Rotogages®, the vent valve is opened and the dip tube rotated slowly from the container vapor space to the liquid space. The difference in appearance of the discharge indicates when the liquid level is reached. Dial readings then indicate the percentage of product in the container. MFR# webb# RGOA9091R — RGOA9092R 162597 RGOA9093RS 190686 RGOA9093TS 162598 RGOA9094RS — RGOA9094TS 162600 RGOA9095RS 162602 RGOA9095TS 162678 RGOA9091-M24.0 — RGOA9091-M36.0 162679 RGOA9091-M48.0 162680 RGOA9091-M60.0 162681 RGOA9091-M72.0 162988
MFR# A9091-18L
For Use With LP-Gas For Stationary Containers Only — — 9093RSM48 9094RSM60 9095RSM72
Container Size Webb# All Sizes Over 1200 U.S. Gallons
162682 —
* Dial permits higher filling level, as per NFPA 58, (1983) Par. 4-5.2.1, Table 4.5.2.1
For Container Inside Diameter
For Use With NH3 For Stationary For Mobile Containers or Stationary Only Containers AA9091RM24 — AA9092RM36 — AA9093TSM48* AA9093RSM48 AA9094TSM60* AA9094RSM60 AA9095TSM72* AA9095RSM72
* Supported design.
LP-Gas
A9091-18LX*
MFR# For Mobile or Stationary Containers 9091RM24 9092RM36 9093TSM48* 9094TSM60* 9095TSM72*
Service
Ellipsoidal Heads
Hemispherical HeadS
Side Mounted
End Mounted
Side Mounted
End Mounted
30” - 45” 46” - 61” 62” - 79” 80” - 99” 100” - 147”
30” - 75” 76” - 108” 109” - 147” — —
30” - 45” 46” - 61” 62” - 79” 80” - 99” 100” - 147”
30” - 45” 46” - 61” 62” - 79” 80” - 99” 100” - 147”
NOTE: The dip tube must be cut to the required length (1/2” of container inside diameter minus 5-3/4”).
Sight Flow Indicators for Bulk Plants
A7794
70
Designed to promote maximum pump efficiency, these indicators enable bulk plant operators to visually inspect liquid flow conditions. With glass on both sides of the indicator, flow can be observed from either side, even under some poor light conditions. The integral swing check also serves as a back-check valve to prevent reverse flow and product loss if the hose fails in a loading operation. By installing an indicator on the upstream side of the plant pump, suction conditions can be observed and the pump speed adjusted to obtain the maximum possible flow rate without cavitation. Additionally, if an indicator is installed in the piping at the loading rack, just ahead of the loading hose, the operator can maintain a constant check on pump conditions. Both installations are designed to allow for observation to provide maximum pump efficiency and assure safe plant pump operation. In compressor operations a sign flow indicator installed in the liquid line will give a visual indication when the tank car or transport is emptied. Compressor operation can then be immediately reversed to start recovery of the vapor. MFR#
Inlet/Outlet Connections
Length
Webb#
A7794 A7796
2” F. NPT 3” F. NPT
53/4” 7”
162712 162713
Gas Equipment Catalog
victormfg.com
SECTION
2
Miscellaneous Equipment Pull-Away Valves for Transfer Operations
A2141A6L
A2141A6 A2141A6L** A2141A8 A2141A10 A2141A16
LP-Gas Liquid Flow Capacity at Various Differential Pressures (GPM)*
Inlet/Outlet Connections NPT F.
Disconnect Force Approx-lbs
Reconnect Force Approx-Lbs
Length of Valve
3/4”
130
80
37/8”
11
16
25
36
1” 11/4” 2”
75 160 300
50 25 50
49/16” 55/8” 145/16”
21 52 250
30 75 350
47 120 550
67 170 750
5 PSIG
10 PSIG 25 PSIG 50 PSIG
Webb# 162683 162684 187008 189203 187007
* To determine NH2 liquid flow capacity, multiply by .90. ** Lanyard.
“Swing-Check” ESVs for Bulk Plants Especially designed for installation in liquid transfer lines at LP-Gas or anhydrous ammonia bulk plants to provide for quick shut-off of liquid or vapor flow in the event of an accidental pull-away or hose rupture, both of which can cause a fire. MFR#
6016 2” ESV
6024 6016 6010 MFR# 6016-60C 6016-60D
For use Only With
Inlet/Outlet Connections
Liquid Low Capacity at 10 PSIG Pressure Drop (GPM)
Webb#
LP LP LP
3” F. NPT 2” F. NPT 1¼” F. NPT
427 (NH3) 427 (NH3) 427 (NH3)
394985 308754 370270
description
Webb#
Pneumatic Open/Close Actuator Pneumatic Release for Point of Transfer
361807 359336
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
71
2 valves & accessories
MFR#
Designed especially to provide pull-away protection for LP-Gas and anhydrous ammonia transfer operations including transport and delivery truck loading and unloading, engine fuel container filling and miscellaneous cylinder filling operations. When properly fastened to the inlet end of the discharge hose, the valve is designed to stop gas escape from both upstream and downstream lines in the event of a pull-away. An excessive tension pull causes the valve to automatically separate, closing two internal back pressure checks. Only a few cubic centimeters of gas escape at the instant of separation. It is recommended that a convenient means be provided to safely remove the pressure from the line upstream of each coupling half to enable reassembly of the valve. To reassemble, simply push the male half firmly into the female half until the retaining balls slip into the retaining groove. Check for leaks after reassembly. NOTE: It is recommended that pull-away valves be safety-tested at least monthly to confirm that they will separate properly in the event of a pull-away. Dry nitrogen or other inert gas is suggested for a source of pressure during such tests.
SECTION
2
Miscellaneous Equipment
Hose End Adapters for DOT Cylinder Filling
7193D-10
Designed to provide quick and easy filling of DOT cylinders with POL or Type 1 connections. This adapter may be used with hydraulic and electric automatic systems or with manual systems in conjunction with a RegO® 7901TB Quick Acting Shut-Off valve. These filling connectors have an extended connection on the handwheel, which make it possible to connect the loading hose to valves on cylinders with fixed collars. The handwheel is well outside the collar for easy operation. mfr#
Applications
Inlet Connection
Filling of DOT Cylinders with POL Connections Filling of DOT Cylinders with Type 1 Connections
7193d-10
7193U-10 7193u-10
1/4” M. NPT
Outlet Connection
Materials
Webb#
M. Pol CGA 510
Brass & Stainless Steel
186884
Type 1 Connection (115/16” M. ACME)
Brass
186886
Connector for DOT Cylinder Filling Adapter The 7193T-10 is designed for use on the 7193D-10 Filling Adapters. Connector allows adapter to be used on the 15/16 M. ACME & F. POL connections of Type 1 valves.
7193T-10
mfr#
Applications
Inlet Connection
7193T-10
Converts 7193D-10 Adapter from POL to a Type 1 Connection
M. POL CGA 510
Outlet Connection Type 1 Connection (115/16” M. ACME)
Materials
Webb#
Brass
162472
Brass Type 1 Fittings & Adaptors Type 1 ACME Appliance Side Fitting X 1/4” Male Pipe
Appliance side swivel nut fitting is female 115/16” F. ACME X 1/4” M. NPT. As the appliance side of the Type 1 connection, it makes a positive connection by threading on to the ACME threads of the valve with a user-friendly right hand turn motion. Mfr# description
Webb#
G1855-A03
POL Green 71–200 BTU
242866
G1855-A02
POL Black 0–70 BTU
182659
G-1850 Evacuation Fitting G-1850
Threads onto Type 1 cylinder valves just like the appliance side, swivel nut fittings. For purging only. Mfr# G-1850
72
Webb# 182658
Gas Equipment Catalog
victormfg.com
SECTION
2
Miscellaneous Equipment Hose End Adapter for Lift Truck Cylinder Filling The 7193L-10A is designed to provide quick and easy attachment of the filling hose to DOT cylinders equipped with RegO® 714M check connectors. 7193L-10A
MFR#
Inlet Connection
Application
1/4” M. NPT
11/4” F. ACME
Brass
5760A
162471
* The 7193L-10A is intended to be permanently attached to the filling hose.
Lever Operated Hose End Adapter for Fork Lift Cylinder Filling Designed to drastically reduce labor and time when continuously filling large numbers of lift truck cylinders equipped with RegO® 7141M check connectors.
7193K-10B
MFR#
Application
Inlet Connection
Outlet Connection
MaterialS
Webb#
7193K-10B
Lever Operated for Quick Filling of Fork Lift Cylinders
1/4” M. NPT
Quick Disconnect York
Brass and Steel
162470
For use with RegO® 7141M check connector.
Quick Connect POL Filling Adapter The 7193R-10 is designed for use in LP-Gas filling systems including fill rooms and dispensing stations. The quick acting lever allows fast connection to POL type (CGA 510) cylinder valves. It fits both compact and heavy duty cylinder valves commonly found on 5 to 100 lbs. DOT LP-Gas cylinders.
7193R-10
MFR# 7193R-10
Application
Inlet Connection
Outlet Connection
Webb#
Lever Operated for Quick Filling of Cylinders with POL Outlet
1/2” F. NPT
Fits Female POL CGA 510
189171
Vent Valves
3165CP
3165C
Especially designed to bleed off liquid or vapor pressures trapped in transfer lines. When installed in the downstream boss of RegO® globe and angle valves used at the end of a liquid transfer hose, the bleeder valve allows for the controlled venting of the product and indicates to the operator that the valves are closed and he can disconnect the coupling. They may also be used as a fixed liquid level gauge where the dip tube is part of the container. MFR#
TSS3169
Service
3165C 3165CP
LP-Gas Only
TSS3169
LP-Gas & NH3
Connection
Actuation
1/4” M. NPT
Knurled Knurled
Accessories Warning Plate Kit
Webb#
2550-40P
162449 186852
Tee Handle
162450
Spanner Wrench for ACME Connectors This aluminum spanner wrench is especially designed for use with 21/4” and 31/4” ACME couplings, adapters and caps. 3195-50
MFR#
For Use with ACME Connector Size
Webb#
3195-50
21/4” & 31/4”
162697
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
73
2 valves & accessories
of Fork Lift 7193L-10A Filling Cylinders*
Accessories Outlet Body Connection Material Adapter Webb#
SECTION
2
Miscellaneous Equipment Fixed Liquid Level Gauges
Especially designed to provide a visible warning when containers are filled to the maximum permitted filling level. At the start of the filling operation, with the vent stem opened, the valve discharges vapor. When the maximum permitted filling level is reached, the valve discharges liquid. These valves are normally furnished with a 12”, 3/16” O.D. dip tube and incorporate a No. 54 drill size orifice. An optional instruction plate with “Stop Filling When Liquid Appears” may be ordered for use with these valves.
MFR#
Service
Connection
Actuation
Dip Tube Length
3165CF05.6 3165CF12.0
LP-Gas Only
1/4” M. NPT
Knurled Knurled
5.6” 12”
Accessories Warning Plate Kit 2550-40P
3165CF12.0
Webb# 189141 186851
Combination Valve for Bulk Storage Containers
A2805C
Designed for installation on bulk storage containers, this valve combines a pressure gauge mounting and provision for a fixed tube liquid level gauge. The shut-off valve prevents the pressure gauge from being subjected to constant pressure, thereby prolonging its life and accuracy. The valve may be closed, and the vent valve opened to vent pressure from the gauge to permit replacement. For fixed liquid level gauging, the valve can be mounted at the maximum permitted filling level. When equipped with a dip tube threaded 1/8” M. NPT, it can be installed at any convenient level. MFR#
Container Connection
Service Connection
Liquid Level Vent
Webb#
A2805C
3/4” M. NPT
1/4” F. NPT for Gauge Mounting
Knurled
162685
Needle Valves
1224WA
74
These valves are high quality, “true” throttling valves. Unlike most so-called needle valves, both the body seat and stem are tapered to provide fine, precise control over a wide range of adjustment without stem galling. The 1224 may be used as a small, inexpensive shut-off valve between a pressure gauge and bulk storage container to allow for convenient gauge replacement. The 1316 provides taper pipe thread by left hand hose connection threads and are useful in a wide range of torch and fuel burner applications where an accurate throttling action is required. MFR#
Inlet Connection
1224WA 1316WA
9/16” - 18 L.H.
1/4” M. NPT
Gas Equipment Catalog
Outlet Connection
Height
Length
Webb#
1/4” M. NPT
19/16”
13/4”
186802 189122
victormfg.com
SECTION
2
Diagrams Bulk Transport Truck
R O TO G A U
G
Vapor Return
GO
2 Liquid Fill
valves & accessories
Liquid
RE
E
Rotogage A9093TS
Spray Fill
Pressure Relief Valve A8436G
Vapor Internal Valves A3213A Internal Valve A3212R
Internal Valve A3212R
Internal Valve A3219FA600L or Flomatic® A7884FK
Adapters 5769H 5769K
Pump Globe Valve A7517AP
Globe Valve A7513AP A7517AP
Angle Valve A7704LP Cap 3184-90
Cap 3184-90 3194-90
Domestic Installation Check Lok 7590U 7591U
Multivalve G8475R Series
Multivalve 7556R Series
Filler Valve 6579 7579
Adapters 5767H Cap 3184-90 A3184-90
Adapters 5769K Cap 3194-90 A3194-90
First Stage Regulator LV4403SR/TR Series LV3403TR Pressure Relief Valve 7583G 8684G 8685G Second Stage Regulator LV4403B Series LV5503B Series
Pigtail 913PS12 912PS12
DOT Container
ine
dL
oun rgr
de
Un
ASME Container
Twin Stage Regulator LV404B4 Series LV404B9 Series LV404B23 Series LV404B29 Series
Service Valve 9101R Series 9101D Series
Pigtail 912JS12 913JS12 Pressure Relief Valve 8544 Series
Filler Valve 7647SC with cap
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
75
SECTION
2
Diagrams Bobtail Delivery Truck
Rotogage A9093TS A9094TS A9095TS
Pressure Relief Valve (2) A8434G CAUTION
Internal Valve A3217F Series or Flomatic速 A7883FK
Check Valve A3146
EG
O RO
T O G AU
G
Check Valve A3186
Check Valve A3176
Pump
R
E
Globe Valve A7513AP
Internal Valve A3209R050/80 A3209TL Globe Valve A7509BP Adapter 5765F Cap 3175P
Cap 3194-90 Angle Valve Adapter A7506AP 5769H Globe Valve A7509BP
Hose End Valve Excess Flow Valve Filling Connector 7574 A7797A Hydrostatic Relief Valve SS8021J
Emergency Shut Off Valves
76
Gas Equipment Catalog
victormfg.com
SECTION
2
Diagrams Bulk Storage Plant Capacity 18,000 to 30,000 Gallons
Internal Valves A3212R A3213A
Caps C5765N C5769N Adapters 3185 3195
R
Vapor ESV 7781AF
Angle Valve A7510BP
Angle Valve A7514AP
R
O R O T G A UG O
Liquid Line
EG
O R O T G A UG O
Rotogage A9095RS
Back Check Valves A3186
Shut-Off Valves A7513AP
Vapor Line
Pull Away Coupling A2141A16
EG
Rotogage A9095RS
E
Globe Valves A7509BP A7513AP
Internal Valves A3212R A3213A E
Angle Valve A7510BP
2
Multiport A8564 A8574
By Pass Valve
Globe Valve A7517AP To Railroad Cars
Liquid ESV 6016 Hydrostatic Relief Valves 3127U or SS8001U
Hydrostatic Globe Valves Relief Valves A7513AP 3127U or SS8001U
Pump Hydrostatic Relief Valves 3127U or SS8001U
Motor Fuel Applications
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
77
valves & accessories
Pull Away Coupling A2141A10
Relief Valves A3149MG
SECTION
2
Repair Kits Repair Kits Available by Part Number ECII part # 901 Series 903 Series A2141A6 Series A2141A8 Series A2141A10 A2141A16
Repair Kits Available 903-50 903-51 A2141A6-50 A2141A6M A2141A8-50 A2141A8M A2141A10-50 A2141A10M A2141A16-50 A2141A16M
A3209A Series
A3209A-50
A3210A Series
A3210A-50
A3212A Series A3213A Series A3217 Series
A3212A-K Kits A3212A-50 A3213A-K Kits A3213A-50 A3217F-50 A3217F-80 O-ring flange
A3217 Series A3217F-80G Gasket flange
A3219F-80 O-ring flange A3219F Series A3219F-80G Gasket flange
LV4403 Series 6532, 6533, 6542, 6543, Series Filler Valve
78
See Instruction Sheets 6542B-50 6542B-80
Gas Equipment Catalog
Contents Bonnet stem and seat disc assembly; large handwheel, self tapping screw Bonnet stem and seat disc assembly; small handwheel, self tapping screw O-Ring seal for female connector Male coupling O-Ring seal for female connector Male coupling O-Ring seal for female connector Male coupling O-Ring seal for female connector Male coupling Bearing; cam; gasket; main seat disc assembly; retaining ring, seal-o-ring; seat disc Bushing, gasket; jam ring; main seat disc assembly; upper and lower retaining rings; o-ring; seal rings(2); seat disc Excess flow spring; o-ring Bearing; cam; gasket; o-rings; seat disc; stem packing Excess flow spring; o-ring Bearing; cam; gasket; o-rings; seat disc; stem packing Dust seal; jam ring; stem o-ring; stem seals (3); stem spring; stem washer Cotter pin; dust seal; inner and outer stem bearing; jam ring; main and pilot seat disc; poppet seal o-ring; retaining ring; roll pins (2); seat o-ring; stem o-ring; stem seals (3); upper and lower flange seal o-ring; wear button Dust seal; inner stem bearing; jam ring; lower flange seal gasket; main seat disc; outer stem bearing; pilot seat disc; poppet seal o-ring; retaining ring; roll pins (2); seat o-ring; stem o-ring; stem seals (3); upper flange seal gasket; wear button Bumber; cotter pins (3); dirt seal; inner and outer stem bearing; lever release spring; main seat disc; poppet seat disc; pivot pin locknut; poppet bearing; seal gland gasket; seat seal o-ring; stem jam ring; stem o-ring; stem seal rings (3); stop screw; upper and lower flange seal o-ring Bumber; cotter pins (3); dirt seal; inner stem bearing; lever release spring; lower flange seal gasket; main seat disc; poppet bearing; poppet seat disc; seal gland gasket; seat seal o-ring; stem jam ring; stem o-ring; stem seal rings (3); stop screw; outer stem bearing; upper flange seal o-ring
Instruction Sheet # 903-300
WEBB# 163019 178960
A2141A-302
—
A2141A-303
—
A3209A-301
187018
A3210A-301
—
A3212-800
—
A3212A-300
—
A3213-800
—
A3213A-300
266446
A3217F-300
—
A3217F-302
—
A3217F-302G
—
A3219F-302
—
A3219F-302G
—
Gasket inlet nipple; seat disc assembly
2503-300N
—
Gaskets; spring; spring guide; stem and seat disc assembly; upper body Gaskets; spring; spring guide; stem and seat disc assembly
6542B-300
162513 162514
victormfg.com
SECTION
2
Repair Kits Repair Kits Available by Part Number (continued) ECII part # 6532, 6533, 6542, 6543, Series Service Valve
Repair Kits Available
7511A-20
Bonnet assembly
19104-50 19104-80 19105
6579 TA7034P TA7034LP 7141M 7177 7188 7193K-10B
7579-50 7579-80 TA7034-50 7141M-50 7177-50 7188-50 7193K-50 7193K-51
A7505AP A7506AP
A7505-50
A7505AP A7506AP
TA7034-50
A7507AP A7508AP
A7507-50
TA7507AP
TA7507-50
TA7509BP A7510BP
7505A-20
7507A-20
TA7509-50 7509B-20 A7509-50 7509B-20
Instruction Sheet #
WEBB#
19104-300
162536
19104-800
162537
19105-300
—
7579-300
186929
7579-300A
162523
TA7034-300
—
7141M-300 7177-300 7188-300
162505 186878 186881
—
—
—
—
A7505-300
—
—
—
TA7034-300
—
A7507-300
162517
—
163075
TA7507-300
—
TA7509-300
—
—
—
A7509-300
162518
—
—
TA7509B-300
187121
A7511-300
—
—
—
ta7509BP TA7510BP A7511AP A7511FP A7512AP A7512FP A7511AP A7511FP A7512AP A7512FP
TA7509B-50
TA7511A-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7511-300
—
A7513AP A7514AP
A7513-50
A7513-300
162520
—
—
A7513AP A7514AP
A7513-20
A7513-300
—
A7513F-20
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly
—
—
TA7513A-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7513A-300
162521
TA7513AP TA7513FP TA7514AP TA7514FP
7513A-20
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
79
2 valves & accessories
A7511-50
Contents Complete MultiBonnet Assembly – bonnet assembly, hardwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Gaskets; seat disc and retainer assembly; spring; upper body Gaskets; seat disc and retainer assembly; spring Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Check assembly; gasket; o-ring; retaining ring Diaphragm; gasket; o-ring; seat disc; washer Hydraulic fluid; o-rings; piston; spring; trip latch 7193A-51 assembly; adjusting screw; nut; spring; tee Check body and disc assembly; gasket; nipple; tailpiece nipple; slip washer Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
SECTION
2
Repair Kits Repair Kits Available by Part Number (continued) ECII part # A7515AP A7516AP A7517AP/FP A7518AP/FP TA7515AP TA7516AP A7517AP/FP A7518AP/FP 7547B Series 7547BX Series 7547SX Series 7547DX 7547FX 7547HX 7550P 7550UP 7551P A7550P A7550PX A7551P T553T Series
Repair Kits Available A7515-50
Contents Gaskets; jam ring; o-ring; pressure seal rings; roll pin; seat disc; washer
A7515-B20
Bonnet assembly
TA7515A-50
Gaskets; jam ring; o-ring; pressure seal rings; roll pin; seat disc; washer
WEBB#
A7515-300
162522
—
—
TA7515A-300
—
7547B-300
—
7547B-80
Gaskets; springs; seat disc and retainer assembly; upper body Gaskets; springs; seat disc and retainer assembly
7547B-300A
186909
7547B-80
Gaskets; springs; seat disc and retainer assembly
7547B-300A
—
7550-15
Bonnet assembly
—
—
A7550-15
Bonnet assembly
—
—
7553T-50
Bonnet; gasket; lever assembly; seat retainer assembly; stem Gasket; o-ring; seat disc Gaskets; o-ring; roll pin; seat disc; spring; stem assembly
7553T-300
—
7553T-301
—
A7553A-300
—
7547B-50
7553T-80
A7553A
A7553A-50
7554LV 7554LAV 7554SV 7554SAV
7554L-20
Bonnet assembly
—
—
7554S-20
Bonnet assembly
—
—
19104-300
162536
19104-800
162537
19105-300
162535
8475-300
162533
8475-81A
Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Body; gaskets; spring; stem and seat disc assembly Gaskets; spring, stem and seat disc assembly
8475-300A
162534
TA7513A-50
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
TA7513A-300
162521
7573A-300
—
7579-300
186929
7579-80
Gaskets; spring, seat disc retainer assembly Gaskets; seat disc and retainer assembly; spring; upper body Gaskets; seat disc and retainer assembly; spring
7579-300A
162523
7647B Series
7647B-80
Gaskets; seat disc and retainer assembly; spring
7647B-300
—
A7704 Series A7705 Series A7706 Series
A7705-50
Flange packing; friction washer; gaskets; seat disc
A7705-300
187046
A7707-50
Gaskets; groove pin; jam ring; o-ring; pressure seal rings; seat disc; washers Bonnet assembly; packing; seat disc and retainer; stem; washers
A7707-300
—
—
187047
7556VR, R Series Service Valve
19104-50 19104-80 19100-50B
7556vr, r Series Vapor Equalizing Valve TA7513AP TA7513FP TA7514AP TA7514FP 7573A Series 7579
A7707L A7708BL
80
Instruction Sheet #
8475-51A
7573A-81 7579-50
A7707-75
Gas Equipment Catalog
victormfg.com
SECTION
2
Repair Kits Repair Kits Available by Part Number (continued) ECII part # A7797 A7853A
Repair Kits Available A7797-50 A7797-75 A7853A-50
A7883FK A7883F-80 A7883F-150 A7883F-50 A7884FK A7884F-80 A7884-150 TA7894P
TA7894-50
7901 Series
7901T-50 7901T-80
A8016DP A8017 Series A8018DP A8017DH
A7797-300
162524
—
162525
A7853A-300
162526
7883-300
247073
7883-300
—
7883-300
189227
7883-300
247073
7883-300
372636
7883-300
—
TA7894-300
—
7901-300 7901-301
162529 —
Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer
A8016B-300
—
A8017BH-20R
Bonnet stem and seat disc assembly; gasket Upper body; gaskets; seat disc ad retainer assembly; spring Gasket; seal; seat disc and retainer assembly; spring Body; gaskets; spring; stem and seat disc assembly Gaskets, spring, stem and seat disc assembly Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw
A8017BH-300
—
8475-50
G8475RV G8475RW Vapor Equalizing Valve
8475-51A
8475-80
8475-81A 19104-50 19104-80 19100-50B
G8475RV G8475RW Fixed Liquid Level Gauge
3165C
Fixed liquid level gauge valve
8542G/AA8542 Series
8540-50
8547W/VWN
8547-2
Bleeder valve assemblies; packing; gland; set screw; washer; gasket; key Bonnet; o-ring and stem assembly Gaskets; spring; spring guide; stem and seat disc assembly; upper body Gaskets; spring; spring guide; stem and seat assembly
8555D/R Series Mfg’d 10/9 or before
WEBB#
A8016B-50
G8475RV G8475RW Filler Valve
G8475RV G8475RW Service Valve
Instruction Sheet #
6542B-50 6542B-80
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
8475-300F
162532 186967
8475-300
162533
8475-300A
162534
19104-300
162536
19104-800
162537
19100-300B
162535
—
—
8540-300
—
—
—
6542B-300
162513 162514
81
2 valves & accessories
A7883F-50
Contents Gaskets; groove pin; jam ring; o-ring; pressure seal rins; seat disc; washers Bonnet and lever asssembly; stem Block v-packing; gaskets; o-rings - piston, stem and yoke; roll pin; seat disc; seat disc retainer assembly; springs Bleeder assembly; bushing; cap; cap screws; filters; gaskets; lock washers; needle valve kit; orings; retaining ring; roll pin; screen filter; seal; set screws; springs; stem assembly kit; v-ring; x-seal Bushing; cylinder cap screws; filters, gaskets; insert; o-rings; retaining ring; seat disc; v-ring; x-seals Gaskets; seat disc; x-seal Bleeder assembly; bushing, cap; cap screws; filters; gaskets; lock washers; needle valve kit; o-rings; retaining ring; roll pin; screen filter; screw; seal; set screws; springs; stem assembly kit; v-ring; x-seal Bushing; cap screws; filters; gaskets; insert; o-rings; retaining ring; seat disc; v-ring; x-seal Gaskets; seat disc; x-seal Gaskets; jam ring; o-ring; pressure seal rings; seat disc; washer Bonnet assembly; gasket; lever Gasket; o-ring; seat retainer assembly
SECTION
2
Repair Kits Repair Kits Available by Part Number (continued) ECII part #
Repair Kits Available 8555-50
8555D/R Series Mfg’d 10/9 Filler Valve
8555-80
8555DL
19100-50B 19104-50
8555D Series Service Valve
19104-80 19100-50B
8555R Series Service Valve A/AA 8560 Series A/AA 8570 Series 8593A/AR Filler Valve 8593A/AR Vapor Equalizing Valve
19104-50 19104-80 8560-50 8475-50 8475-80 8475-51A 8475-81A 19104-50
8593A/AR Service Valve
19104-80 19100-50B 19104-50
9101C, D, H, R, P, Y Series Service Valve
19104-80 19100-50B 19101-50
9103C, D Series Service Valve
19104-50 19104-80 19100-50B
9103T9F 9106CO 9107K8A, K2A
19105-50 903-50 903-51 19100-50B 19104-50
9300Y/R
19104-80 19100-50B
82
Gas Equipment Catalog
Contents Gaskets; spring; spring guide; stem and seat disc assembly; upper body Gaskets; spring; spring guide; stem and seat disc assembly Bonnet; stem and o-ring assembly; hardwheel; self tapping screw Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bleeder valve assemblies; seat ring assemblies; pressure seal rings; packing gland; jam ring; washer; gasket Gaskets; seat disc and retainer assembly; spring; upper body Gasket; seal; seat disc and retainer assembly; spring Body; gaskets; spring; stem and seat disc assembly Gaskets; spring; stem and seat disc assembly Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Bonnet; stem and o-ring assembly; handwheel (small); self tapping screw Complete MultiBonnet Assembly – bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw Bonnet; stem and o-ring assembly; handwheel; self tapping screw Bonnet; stem and seat disc assembly; large handwheel; self tapping screw Bonnet; stem and seat disc assembly; small handwheel; self tapping screw Bonnet; stem and seat disc assembly; handwheel; self tapping screw Complete MultiBonnet Assembly - bonnet assembly, handwheel, nameplate and self tapping screw Upper packing with seal rings – For MultiBonnet only Bonnet; stem and o-ring assembly; handwheel; self tapping screw
Instruction Sheet # 8555-300
WEBB# 378312 378313
19100-300B
162535
19104-300
162536
19104-800
162537
19100-300B
162535
19104-300
162536
19104-800
162537
7564-300
—
8475-300F
162532 186967
8475-300
162533
8475-300A
162534
19104-300
162536
19104-800
162537
19100-300B
162535
19104-300
162536
19104-800
162537
19100-300B
162535
19101-300
—
19104-300
162536
19104-800
162537
19100-300B
162535
19105-300
—
903-300
163019 178960
19100-300B
162535
19104-300
162536
19104-800
162537
19100-300B
162535
victormfg.com
SECTION
2
Repair Kits Repair Kits Available for Obsolete Part Numbers ECII part # 1470 LV 1480V Series 1470W 1480W Series
1470, 1480 Series Service Valve 1470, 1480 Series Vapor Equalizing Valve AA1582E Series AA1584E Series AA1586E Series 2180 Series 2403 Series 2418 2418, 2550 Vapor Equalizing Valve 2465L, 2486 2503 Series 2250 2250 Vapor Equalizing Valve 2555 Series 2577 2577 Series
Contents
Instruction Sheet #
WEBB#
May be replaced with G8475RV Series
—
May be replaced with G8475W Series
—
2
3100-80A 3100-80B 3100-81K
Bonnet; Diaphragm assembly; stem Diaphragm assembly; washer Conversion kit; bonnet and stem assembly
3100K-300
162510 162511 162512
1475-80
Seat disc and stem assembly; spring; washer
1475-300F
—
2418-51
Body, gasket; seat disc and stem assembly; spring; washer
—
—
3100-301
AA1582E-300 AA1584E-300 AA158E-300 Replace with 8555D/R for cylinders with up to 200# propane capacity, for containers with capacities up to 400# use 6533A/R See Instruction Gasket; inlet nipple; seat disc assembly 2503-300N Sheet Replace with G8475RV Body, gasket; seat disc and stem assembly; 2418-51 — spring; washer No repair parts available - replace with G8475RV Series See Instruction Gasket; inlet nipple; seat disc assembly 2503-300N Sheet Replace with G8475RV Series Body, gasket; seat disc and stem assembly; 2418-51 — spring; washer Replace with 6532, 6533, 6542, 6543 Series No repair parts or replacement valve available Replace with 6532, 6533, 6542, 6543 Series AA1582E-50
Diaphragm and yoke assembly (standard); screen; small spring; stem and seat disc retainer assembly; tetraseals
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
— — — — — — — — — — — — — —
83
valves & accessories
1470, 1480 Series Service Valves
Repair Kits Available
SECTION
2
Repair Kits Repair Kits Available for Obsolete Part Numbers (continued) ECII part # 2580, 2581 2593, 2594 2593K, 2594K 2593/K, 2594/K Service Valve 2593/K, 2594/K Filler Valve 2593/K, 2594/K Vapor Equalizing Valve 3103
Repair Kits Available
Contents
No repair parts or replacement valve available – replace with 8555D/8555R Series Replace with 8593AR16.0 No replacement available 3100-80A Bonnet; Diaphragm assembly; stem 3100-301 3100-80B Diaphragm assembly; washer 3100-81K Conversion kit; bonnet and stem assembly 3100K-300 1475-80
Seat disc and stem assembly; spring; washer
Body; gasket; seat disc and stem assembly; spring; washer Replace with 9103 for cylinders 100 lbs. or less Body; gaskets; seat disc and retainer assembly; 8475-51A spring; stem 6477A Vapor Equalizing Valve Gaskets; seat disc and retainer assembly; 5475-81A spring; stem Bonnet assembly; large handwheel; 903-50 6532D, 6533D, 6542D, self tapping screw 6543D Bonnet assembly; large handwheel; Service Valve 903-51 self tapping screw 6542B-50 Body, gasket; seat disc assembly; spring; stem 6532, 6533, 6542, 6543 Filler Valve 6542B-80 Gaskets; seat disc assembly; spring; stem Gaskets; jam ring, o-ring; pressure seal rings; A7016A A7505-50 seat disc; washer 7555 Replace with 8555D/R Series 7556 Mfg’s before 1962 8100-50 Bonnet assembly; handwheel A7762B, A7727B, Gaskets; flange packing; friction washer; AA1582F-50 A7728B seat disc Gaskets; seat disct and retainer assembly; 7747 Series 7547B-50 spring; upper body Bonnet; o-ring and stem assembly; handwheel; 8100 Series 8100-50 self tapping tee 8103 Series No repair kits available - replace with 9103 Series G8475 Mfg’d before 8100-50 Bonnet assembly; handwheel 1962 Body; gaskets; seat disc and retainer assembly; 8475-50 spring G8475 Filler Valves 8475-50 Gaskets; seat disc and retainer assembly; spring Body, gaskets; seat disc and retainer assembly; 8475-51A spring; stem G8475 Vapor Equalizing Valve Gaskets; seat disc and retainer assembly; 8475-81A spring; stem 8477 Replace with G8475RV 8477 Mfg’d before 1962 8100-50 Bonnet assembly; handwheel Service Valve
84
Instruction Sheet #
2418-51
Gas Equipment Catalog
WEBB# — — — 162510 162511 162512
1475-300F
—
—
— —
—
162533
—
162534
903-300
163019 178960
6542B-300
162513 162514
A7505-300
—
8100-300
— 162531
A7726B-300
—
7547B-300
—
8100-300
162531 —
8100-300 8475-300F
162531 162532 186967
8475-300
162533
8475-300A
162534 —
8100-300
162531
victormfg.com
SECTION
2
Repair Kits Repair Kits Available for Obsolete Part Numbers (continued) ECII part # 8477 Mfg’d before 1962 Vapor Equalizing Valve
Repair Kits Available 8475-51A 8475-81A
Contents Body; gaskets; seat disc and retainer assembly; spring; stem Gaskets; seat disc and retainer assembly; spring; stem
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
WEBB#
8475-300
162533
8475-300A
162534
8100-300
162531 —
19100-300B
162535
8475-300
162533
8475-300A
162534 —
903-300 6542B-300 8475-300F
163019 178960 162513 162514 162532 186967
8475-300
162533
8475-300A
162534 —
8100-300
162531
19100-300B
162535
8475-300F
162532 186967
8475-300
162533
8475-300A
162534
85
2 valves & accessories
8484 Mfg’d before 1962 8100-50 Bonnet assembly; handwheel Service Valve 8484A No replacement valves available 8484A 19100-50B Bonnet assembly; handwheel Service Valve Body; gaskets; seat disc and retainer assembly; 8475-51A spring; stem 8484/A Vapor Equalizing Valve Gaskets; seat disc and retainer assembly; 8475-81A spring; stem 8555 Series Mfg’d No repair parts available – replace with 8555D/R Series before 1962 Bonnet assembly; large handwheel; 903-50 self tapping screw 8555S Series Service Valve Bonnet assembly; small handwheel; 903-51 self tapping screw 6542B-50 Body; gaskets; seat disc assembly; spring; stem 8555S Series Filler Valve 6542B-80 Gaskets; seat disc assembly; spring; stem Body; gasket; seat disc and retainer assembly; 8475-50 8593/K spring Filler Valve 8475-80 Gaskets; seat disc and retainer assembly; spring Body; gaskets; seat disc and retainer assembly; 8475-51A spring; stem 8593/K Vapor Equilizing Valve Gaskets; seat disc and retainer assembly; 8475-81A spring; stem 8594 Replace with 8593AR16.0 8594/K Mfg’d before 8100-50 Bonnet assembly; handwheel 1962 Service Valve 8594/K Mfg’d before Bonnet and stem assembly; handwheel; 19100-50B 1962 Service Valve self tapping screw Body; gaskets; seat disc and retainer assembly; 8475-50 spring 8594/K 8475-80 Gaskets; seat disc and retainer assembly; spring Body; gaskets; seat disc and retainer assembly; 8475-51A spring; stem 8594/K Gaskets; seat disc and retainer assembly; 8475-81A spring; stem
Instruction Sheet #
SECTION
3
Meters/Meter Accessories Single Joint Residential Gas Meter R-275, 275 SCFH
These class 250 residential meters are an improved revision of the R-200 family. The latest design concepts and modern engineering materials have been combined to provide a lighter weight, easier to handle, more durable meter which requires less maintenance and offers greater life expectancy. All models stocked are temperature compensated.
Specifications
Kits Available
capacity scfh 1/2” w.c. diff.
R275
MAX. APPROX. METER W.P. SHPG. CONNECTIONS But. prop. PSI WT. LBS AVAILABLE Webb#
MFR# R-275-20 Lt. R-275-30 Lt. R-415-30 Lt. S-275
150
175
5-10
14
225 150
260 175
10-125 5-10
21 14
20 Lt. 30 Lt. 30, 45 Lt. 3/4” NPT
244671 244675 244672 181926
with swivels, nuts & gaskets included. MFR#
Webb#
R-275-20LTK R-275-30LTK R-415-45LTK
181925 244642 181919
Natural Gas Capacities Meter Model
capacity rating at 1/2” w.c. differential
capacity rating at 2” w.c. differential
Webb#
750* 1000*
750 cfh 1000
1600 CFH 2200
181924 181911
* In Stock – Soon to be obsolete
Propane Gauge pressure (PSIG) 0.25 5 10
differential 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow
750 990 1340 1120 1630 1260 1920
1600 990 1340 1120 1630 1260 1920
1000 1360 1850 1540 2240 1740 2640
3000 1860 2520 2100 3060 2370 3600
5000 3100 4200 3500 5100 3950 6000
10000 6200 8400 7000 10200 7900 12000
Specifications
Meter Model 750 1000 3000 wo/flanges* 5000 wo/flanges* 10000 wo/flanges*
MAXIMUM WORKING PRESSURE (PSIG) 20 25 100 100 100
capacity rating at 1/2” w.c. differential of 0.6 Sp. Gr. gas cfh 750 1000 1450 2500 5000
capacity rating at 2” w.c. differential of 0.6 Sp. Gr. gas cfh 1600 2200 3000 5000 10000
STANDARD CONNECTIONS 45 Lt. 45 Lt. 3” - 8” PT 4” - 8” PT 4” - 8” PT
* Special Order
86
Gas Equipment Catalog
victormfg.com
SECTION
3
Meters/Meter Accessories Intermediate and Large Capacity Diaphragm Type Gas Meters (continued) Natural Gas Capacities SCFH of 0.6 Sp. Gr. Gas at Elevated Pressures Gauge Pressure (PSIG) 0.25 5 10
20 25 40 50 70 100
750 1600 1600 1840 2070 2080 2480 2320 2840 2480 3230
1600 1600 1600 1840 2070 2080 2480 2320 2840 2480 3230 2640 3570 3120 4450 3360 5000 3840 5960 4480 7170
1000 2200 2200 2530 2840 2860 3420 3190 3960 3410 4440 3630 4900
3000 3000 3000 3450 3880 3900 4660 4350 5400 4650 5820 4950 6700 5850 8700 6300 9370 7200 11200 8400 13400
5000 5000 5000 5750 6450 6500 7760 7250 9000 7750 10100 8250 11100 9750 13900 10500 15600 12000 18700 14000 22400
10000 10000 10000 11500 12900 13000 15550 14500 18000 15500 20200 16500 22300 19500 27800 21000 31200 24000 37400 28000 44800
Quick Reference Meter Capacity Chart MFR# R275/S275 R415 750 1000 1600 *
NAT GAS CAP 1/2” DIFF. 275,000 415,000 750,000 1,000,000 800,000
NAT GAS CAP 2” DIFF. — — 1,600,000 2,200,000 1,600,000
NAT GAS CAP 5 PSI — — 1,840,000 2,530,000 1,840,000
NAT GAS 10 PSI — 850,000 280,000 3,420,000 2,080,000
LP CAP
1/2” DIFF
435,000 647,000 1,866,000 2,488,000 1,866,000
LP CAP 2” DIFF. — — 2,463,120 3,383,680 263,120
LP CAP 5 PSI — — 2,786,560 3,831,520 2,786,560
LP CAP 10 PSI — — 3,134,880 4,329,120 3,134,880
(2 PSIG + 14.48 PSIA) / 14.80 PSIA = 1.114 Correction Multiplier for 2 PSI at Sea Level (5 PSIG + 14.48 PSIA) / 14.80 PSIA = 1.316 Correction Multiplier for 5 PSI at Sea Level (10 PSIG + 14.48 PSIA) / 14.80 PSIA = 1.654 Correction Multiplier for 10 PSI at Sea Level * 100 PSI Max
To correct the actual cubic foot index reading to base (standard) conditions, the pressure multiplier is calculated by adding the line (gauge) pressure to the average atmospheric (psia) then dividing by the base pressure (psia). Eg: Pressure Multipler = (10 psig + 14.48 psia) ÷ 14.73 psia = 1.662
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
87
3 Meters/meter accessories
15
differential 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow 2” w.c. Max. Allow
SECTION
3
Meters/Meter Accessories How to Identify Parts
Material Specifications Body/End Piece
Cast Iron Per ASTM A 126 Class B
Plug/Cap Stem
Cast Brass – ASTM B 584/Alloy 83600 or Alloy 84400
Brass Ball
CDA3600
Brass Nuts & Washers (Plug Valve)
ASTM B 584/Alloy B83600 or Alloy 84400 or MPIF Std. 35 CZ 3002
O-Rings/Torque Seals
Buna-N (Nitrile) or Neoprene Rubber
Port Seals (Ball Valve)
Neoprene Rubber
Union Tailpieces
Zinc plated yellow dichromate finished steel
Insulated Union Tailpieces
Zytel nylon insulation
Union Nut
Malleable Iron Per ASTM A 47 or Ductile Iron Per ASTM
Multiple Meter Manifold MFR# M080KPL070A M080KPL070C MSAFWWEB01
dESCription WEBB# 318128 11/4” Multiple Meter Manifold With Two 1” Outlets Spaced 12” On Center 318127 11/4” Multiple Meter Manifold With Three 1” Outlets Spaced 12” On Center 318552 Meter Manifold Complete 3/4” In 1” Out With Rego LV4403B66 Regulator, Coated Manifold, Meter Bar With 20 LT Swivels, 1” Dielectric Union 24±1/8 12±1/8
6±1/8
2±1/8
7/8±1/64 PORT
M080KPL070A
MSAFWWEB01
36±1/8 6±1/8
12±1/8
2±1/8
7/8±1/64 PORT
M080KPL070C
88
Gas Equipment Catalog
victormfg.com
SECTION
3
Meters/Meter Accessories
Cast Iron Meter Bars
Accessories
Horizontal Inlet and Outlet 6610 Series — 6” Centerline
6610-B
Meter Nuts — 30LT
Meter Nuts are used to connect straight and/or offset swivel gas fittings to the gas meter. Manufactured per ANSI B109.1.
Integral FIP
Meter Plugs — 20LT Meter Plugs are used to prevent the unintentional flow of gas from meter sets without meters attached. They also prevent insects and other foreign matter from entering the gas piping.
6610-F dESC. WEBB# 1” 250082
A 1
B 1
C 1
Gaskets are used to seal malleable iron offset or straight fittings on the face of the gas meter when tightening the swivel nut on meter thread of meter nut plug. These rubber gaskets made of Buna-N or neoprene are resistant to the action of natural and manufactured gases. The inside diameter is intended to lightly grip the pilot O.D. of the fitting to minimize problems during assembly of the swivel nut to the meter
Cast Iron Meter Bars With Integral Swivels Horizontal Inlet and Outlet 6620 Series — 6” Centerline
6620-B
Integral FIP
A 1
6620-F
B 1
C 20LT
MFR# EQU0016115402000 EQU0016115503000 EQU0016215502000 EQU0014116600000 EQU0014116707000 EQU0014116800000
dESCription WEBB# 20 LT Washer 244635 30 LT Washer 244638 45 LT Washer 244643 20 LT Black Nut 244636 30 LT Black Swivel Nut 244639 45 LT Black Nut 244644
Female insulated flat gasket union
Cast Iron Meter Bar
Steel Fabricated Accessories
Rear Center Horizontal Inlet and Vertical Outlet (Direct Center/Horizontal Inlet) 6722 Series — 6” Centerline
Brackets for Risers PRODUCT MFR# dESCription SUPPORT WEBB# BRKL-6 6” Wall Bracket Riser 252457 BRK9H 9” Wall Bracket Riser 253223 BRK38-01 14” Adjustable Wall Bracket Riser 192635
For multiple meter manifold applications.
6722-F
Gasket for Meter Swivels — 20LT & 30LT
Female insulated flat gasket union
MFR# dESC. WEBB# AYM6722-C-C Swivels 250083
A 1
B 1
C 20LT
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
89
Meters/meter accessories
MFR# AYM6610-F-1X1X1
3
SECTION
4
Cylinders, Tanks & Accessories Steel Cylinders
6.5 in./165.1 mm
Worthington’s steel portable cylinders in eight sizes for commercial, industrial, recreational and home applications. These cylinders are manufactured to Department of Transportation (DOT) 4BA-240 specifications.
9.125 in./ 231.8 mm
9.125 in./ 231.8 mm
4.25 lbs. to 60 lbs. LPG Cylinders
16.625 in./ 422.3 mm
11.625 in./ 295.3 mm
6.5 in./165.1 mm
4.25 lbs.
12.125 in./ 308 mm
12.125 in./ 308 mm
11 lbs.
17.625 in./ 447.6 mm
23.687 in./601.6 mm
6.5 in./165.1 mm
6.5 in./165.1 mm
20 lbs.
MFR# G/T4.5-OPD G/T11-OPD G/T20-OPD G/T30-OPD G/T40-OPD G/T43 G/T60
valve Type 1 With OPD Type 1 With OPD Type 1 With OPD Type 1 With OPD Type 1 With OPD POL Valve POL Valve
size 4.5 lbs. 11.0 lbs. 20 lbs. 30 lbs. 40 lbs. 43.5 lbs. 60 lbs.
MFR# G/T20H-OPD G/T30H-OPD G/T40H-OPD
Description 20# Horizontal Cylinders 30# Horizontal Cylinders 40# Horizontal Cylinders
webb# 194227 194228 190980 190983 194229 223351 185251 webb# 259991 259992 253750
12.125 in./ 308 mm
12.125 in./ 308 mm
30 lbs.
6.5 in./165.1 mm
40 lbs.
32.5 in./825.5 mm
29.250 in./743 mm
6.5 in./165.1 mm
G/T40H-OPD
G/T20H-OPD
12.25 in./ 311 mm
43.5 lbs.
6.5 in./165.1 mm
42.2 in./1071 mm
G/T30H-OPD Size LPG Capacity Water Capacity Tare Weight
60 lbs.
Collar Height Footring Dia. o/s
90
4.25 lbs. 1.0 gal. 3.8 liters 12.0 lbs. 5.4 kg. 11.9 lbs. 5.4 kg. 4.0 in. 101.6 mm 9.1 in. 231.2 mm
Gas Equipment Catalog
11 lbs. 2.6 gal. 9.8 liters 26.2 lbs. 11.9 kg. 13.8 lbs. 6.3 kg. 4.0 in. 101.6 mm 7.8 in. 198.4 mm
20 lbs. 4.7 gal. 17.9 liters 47.6 lbs. 21.6 kg. 17.0 lbs. 7.7 kg. 4.0 in. 101.6 mm 7.8 in. 198.4 mm
30 lbs. 7.1 gal. 26.8 liters 71.5 lbs. 32.4 kg. 25.4 lbs. 11.5 kg. 4.0 in. 101.6 mm 7.8 in. 198.4 mm
40 lbs. 9.4 gal. 35.7 liters 95.2 lbs. 43.2 kg. 33.6 lbs. 15.2 kg. 4.0 in. 101.6 mm 7.8 in. 198.4 mm
43.5 lbs. 10.3 gal. 38.8 liters 103.6 lbs. 47.0 kg. 34.4 lbs. 15.6 kg. 5.1 in. 129.5 mm 12.0 in. 304.8 mm
60 lbs. 14.2 gal. 53.5 liters 142.9 lbs. 64.8 kg. 48.0 lbs. 21.8 kg. 5.1 in. 130.2 mm 12.00 in. 304.8 mm
victormfg.com
SECTION
4
Cylinders, Tanks & Accessories Aluminum Cylinders 6 lbs. to 40 lbs. LPG Cylinders
Attractive, corrosion-resistant aluminum makes the ideal cylinder for home and recreational use. These cylinders are lightweight and easy to handle, but durable for the most demanding applications. The exterior finish is smooth and sleek. The interior is clean, dry and free of foreign matter. All aluminum cylinders meet DOT-4E specifications. MFR# G/TA6-OPD G/TA10-OPD G/TA20-OPD G/TA30-OPD G/TA40-OPD Size LPG Capacity
Tare Weight Collar Height
6 lbS. 1.4 gal. 5.4 liters 15.0 lbs. 6.8 kg. 8.0 lbs. 3.6 kg. 6.5 in. 165.1 mm
size 6 lbs. 10 lbs. 20 lbs. 30 lbs. 40 lbs.
webb# — — 185252 185253 254110
10 lbS. 2.4 gal. 9.8 liters 23.8 lbs. 10.8 kg. 10.1 lbs. 4.6 kg. 5.5 in. 139.7 mm
20 lbS. 4.7 gal. 17.9 liters 47.6 lbs. 21.6 kg. 14.1 lbs. 6.4 kg. 5.5 in. 139.7 mm
30 lbS. 7.1 gal. 26.8 liters 71.5 lbs. 32.4 kg. 18.0 lbs. 8.2 kg. 5.5 in. 139.7 mm
4
40 lbS. 9.4 gal. 35.7 liters 95.2 lbs. 43.2 kg. 20.9 lbs. 9.5 kg. 5.5 in. 139.7 mm
Steel Motor Fuel Cylinders
26.75 in./679.45 mm
33.5 lbs. Forklift Cylinders
Steel forklift cylinders feature two-piece construction with one horizontal weld for a stronger, better looking cylinder with less chance of leakage. The rugged, damage- resistant footring minimizes future repairs. Interior cylinder walls are smooth, dry and free of foreign matter. MFR# description G/T33MF No Filler Valve G/T33MFA 13/4 Filler Valve G/T43MFA 13/4 Filler Valve
size 331/2 lbs. 331/2 lbs. 431/2 lbs.
webb# 185239 185240 252696
Motor Fuel Cylinders
33.5 lbs.
Aluminum Motor Fuel Cylinders 12.5 in./317.5 mm
33.5 lbs. Forklift Cylinders
A: Universal float gauge B. Liquid service valve C. Safety relief valve D. Fixed liquid level E. Vapor service (plugged) F. Liquid fill port (plugged)
Worthington combines the highest standards of manufacturing quality with the light weight and durability of aluminum to provide you lift truck cylinders that readily return your investment through savings in handling, repairs, maintenance, and customer preference. Manufactured in accordance with DOT-4E240 specifications. MFR# DESCRIPTION size webb# — G/TA33MF Aluminum, No Filler Valve 331/2 lbs. G/TA33MFA Aluminum, 13/4 M. ACME Filler Valve 331/2 lbs. 185255
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
91
cylinders, Tanks & accessories
Water Capacity
valve Type 1 With OPD Type 1 With OPD Type1 With OPD Type1 With OPD Type1 With OPD
SECTION
4
Cylinders, Tanks & Accessories Composite Cylinder Pads mfr # description VCT420PAD Composite Pad for 420/200
webb# 433676
DOT/ASME LPG Cylinders 14.625 in./371.5 mm
100, 200, & 420 lbs. Cylinders
48.5 in./1232 mm
6.5 in./165.1 mm
• Exceptional quality and service. Manufactured to DOT, Transport Canada or ASME specifications. • All gas containment welds are automatic MIG/submerged arc welds. • All tanks are 100% leak tested before and after mechanical valve installation. • All tanks pretreated with chemical wash to improve corrosion resistance and powder coating adhesion. • Worthington’s manufacturing process minimizes odorant fade and maximizes paint coating quality. • Worthington’s Durabond 2000 powder paint finish is the highest quality and most durable powder coating available in the industry. • Tank interiors are clean, dry, and free of foreign matter. • Can be used in multiple cylinder installations. • Now with the industry’s largest diameter “user friendly” collar for more work room during filling. • On-time delivery and competitive pricing. Readily available during peak season to service new business.
100 lbs. A: Multi-Valve (3/4”) NPT B: NPT Float Gauge (!”) NPT
92
DOT Cylinders MFR# G/T100ASME G/T100ASME-G G/T100 G/T100M G/T100MW G/T200 G/T200G G/T100M G/T420 G/T420G
valve Tall 100# ASME Less Gauge 100# Squat With Gauge POL Service Multivalve Multivalve Multivalve Multivalve Multivalve Multivalve POL Multivalve POL
Gas Equipment Catalog
size 100 lbs. 100 lbs. 100 lbs. 100 lbs. 100 lbs. 200 lbs. 200 lbs. 200 lbs. 420 lbs. 420 lbs.
Color White White Gray Gray White White Gray Gray White Gray
webb# 263468 269529 185223 185226 194259 185229 192637 185226 185243 192638
victormfg.com
SECTION
4
Cylinders, Tanks & Accessories DOT/ASME LPG Cylinders
(continued)
G/T100ASME G/T100ASME-G
4
24 in./610 mm
39.7 in./1008 mm
ASME Cylinders MFR# G/T200ASME G/T200ASMEG G/T420ASME G/T420ASMEG
valve Multivalve Multivalve Multivalve POL Multivalve POL
size 200 lbs. 200 lbs. 420 lbs. 420 lbs.
Color webb# White 190984 Gray 193312 White 185244 Gray 193311
16 in./407 mm
Size LPG Capacity Water Capacity Tare Weight 30 in./762 mm
51.7 in./1313.2 mm
200 lbs.
Collar Height Footring Dia. o/s
100 lbS. 23.6 gal. 89.3 liters 239.0 lb. 108.4 kg. 71.0 lb. 32.2 kg. 5.1 in. 130.2 mm 14.5 in. 368.3 mm
200 lbS. 47.2 gal. 178.5 liters 474 lbs. 215.0 kg. 158.0 lb. 71.7 kg. 6.6 in. 167.6 mm 19.0 in. 482.6 mm
420 lbS. 99.1 gal. 374.9 liters 1000 lb. 453.6 kg. 272.0 lbs. 123.4 kg. 6.6 in. 167.6 mm 22.0 in. 558.8 mm
How to Order a Truckload 11 bundles make up a truckload. Special colors, or plastic mesh protective coatings are available upon request. There is a quantity of 9-420’s in a bundle, and 16-200’s in a bundle. You must specify DOT or ASME style tanks at time of order. Minimum order of 3 bundles is considered a partial truckload. No more than 3 different stops per truckload within a 150 mile radius.
420 lbs. Description and Size of 420# L.P.G. Cylinder Openings A: Safety Relief Valve (1”) NPT B: Fill Valve (3/4”) NPT C: NPT Float Gauge (1”) NPT D: Vapor Service Valve (3/4”) NPT
Open Collar 100# Cylinders mfr # PIGME350A
Description Multivalve
webb# 186562
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
93
cylinders, Tanks & accessories
16 in./407 mm
SECTION
4
Cylinders, Tanks & Accessories Underground/Aboveground Tanks
Underground Tanks MFR# G/T120UG G/T250UG G/T320UG G/T500UG G/T1000UG
capacity in w.g.
overall length
outside diameter (in)
overall height with 26” riser
weight
number per stack
number per load
webb#
120 250 320 500 1000
5’ - 8” 7’ - 8” 9’ - 6” 10’ - 0” 15’ - 10”
24” OD 30” OD 30” OD 37” OD 41” OD
32” 38” 38” 65” 69”
260 480 620 940 1800
12 5 5 5 5
96 30 25 25 15
265267 185234 185238 185249 185225
Aboveground Tanks MFR# G/T120AG G/T250AG G/T320AG G/T500AG G/T1000AG
capacity in w.g.
overall length
outside diameter (in)
LEG SPACING
weight (lbs)
number per stack
number per load
webb# (WHITE)
WEBB# (GREY)
120 250 320 500 1000
5’ - 7” 7’ - 8” 9’ - 6” 10’ - 0” 15’ - 10”
24” OD 30” OD 30” OD 37” OD 41” OD
371/2” 60” 60” 60” 138”
260 480 620 940 1800
14 9 9 6 5
112 54 45 30 15
205731 185233 185237 185248 185224
— 198025 — 198024 —
AG/UG Tank MFR# G/T120AG/UG G/T250AG/UG G/T320AG/UG G/T500AG/UG G/T1000AG/UG
capacity in w.g.
overall length
outside diameter (in)
overall height w/ riser
LEG SPACING
weight (LBS)
number per stack
number per load
webb#
120 250 320 500 1000
5’ - 8” 7’ - 9” 9’ - 11” 10’ - 0” 15’ - 10”
24” OD 30” OD 30” OD 37” OD 41” OD
36” 40” 40” 47” 51”
371/2” 60” 60” 60” 138”
260 480 620 940 1800
12 9 9 6 5
96 54 45 30 15
185228 202413 193388 194172 204553
500 Aboveground Tank with 11/4 Bottom Opening for Fill Stations MFR# G/T500AG-B
capacity in w.g.
overall length
outside diameter (in)
LEG SPACING
weight (LBS)
webb#
500
10’ - 0”
37” OD
60”
950
215818
All 1000 AG come standard with bottom 11/4 NPT opening.
Notes The chart for AG models is applicable to AG/UG and UG models with the following exceptions: 120 and 150 AG/UGs—stack drops from 14 to 12. 250 and 320 UGs—stack drops from 9 to 5 tanks. 475 and 500 UGs—stack drops from 6 to 5 tanks. • A full load must measure between 46’ and 50’. • We can ship 52’ (not allowed in some states) if the load meets additional criteria. (Must be all AG tanks)
94
Gas Equipment Catalog
victormfg.com
SECTION
4
Cylinders, Tanks & Accessories DOT vs. ASME DOT 240 psi Working Pressure 325 Test Pressure Re-Inspection After 12 Years Transportation Legal With Product
ASME 250 psi Working Pressure 375 Test Pressure No Current Re-Inspection Requirements No Transportation With More than 5% Product
DOT vs. ASME DOT Weld Repairable Heat Treated During Manufacture No Information Data Plate 70,000 Tensile
ASME Not Weld Repairable **Licensing Required Not Heat Treated During Manufacture Information Data Plate 75,000 Tensile
DOT vs. ASME Similar in that:
4
Remote Level Indicator mfr # description RBSRS-228 Remote Level Indicator
webb# 314605
Complete Remote Fuel Level and Temperature Monitoring System MFR#
Description
1000ag
1000ug
420
30K Bulk
WEBB#
REC-1
Controller; Modem Only
RECINT-1
Controller; Modem and Internet
x
x
x
x
432209
ITP-1
Solar Powered Transmitter
x
x
x
x
432205
SEN-1-24
Standard 24” Sensor Cable
x
SEN-1-24-RA
Right Angle 24” Sensor Cable for Underground Tank
ITP-1-STOR
Storage Tank Transmitter with Magnetic L Bracket.
x
432206
SEN-MAG-XX
Sensor for Magnetel Dial with up to 96” length. XX= length. 96” will locate the transmitter on the side of a 30,000 tank. Does not include dial.
x
432212
BATT-ITP-1
Battery Pack for Integrated Transmitter (ITP-1); Installation tool to activate a 6 second RF transmission rate.
CABLE
9V Contoller Cable; Installation tool to allow walkabout testing of receiver.
432204
PROG
Handheld Programmer
432207
432208
x
432210
x
Reusable. One required per installation
432211
432203
RSS has other accessories to suppport custom installations. TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
95
cylinders, Tanks & accessories
Similar Wrapper Thickness Same Valves Save the Pressure Relief Same Strong Wide Collar Same Strong Footring Same Liftlugs Same Valve Configurations on 420’s All Vacuum Purged
SECTION
4
Cylinders, Tanks & Accessories “Wall Hugger” Cylinder Vise Big Performance, Small Profile
The unique design of this powerful cylinder vise allows you to replace cylinder valves quickly and easily, yet does not require a lot of valuable dock space. The “Wall Hugger” actually uses less floor space than this catalog! MFR# description AMDCV-1 Cylinder Vise
webb# 202780
Pump Station Enclosure Protect Your Equipment
• Double doors, Heavy duty load bearing floor. • Adjustable top shelf. • “Duty to Warn” decals. • Tamper resistant hardware.
“Wall Hugger” Cylinder Vise
MFR# description PS302LD 68” X 44” X 30” PS303LD 68” X 44” X 39”
webb# — 184880
Pump Station Enclosure
“Little Giant” Stationary Tank Inverter Will lift and invert all cylinders from a single (or double) 100# thru a full 420#. Indexes to 90°, 180° or 45° to facilitate valve relacement, evacuation and bottom maintenance. Doubles as a vice. Small 3’ X 4’ base saves dock space. MFR# description AMDLG Tank Inverter
“Little Giant” Tank Inverter
webb# 184881
20 Pound Cylinder Cabinets MFR# description AMDLB06302SS 6 Capacity AMDLB12302MS 12 Capacity, 3 Wide
webb# 202790 202792
Fork Lift Cabinets MFR# description AMDFH12302LS 12 Capacity, 3 Wide, Horizontal AMDFV06302MS 12 Capacity, 3 Wide, Vertical AMDFH16402LD 16 Capacity, 4 Wide, Horizontal
webb# 202791 202793 202794
Portable Beam Utility Scale Model 1124
42.5” Tall
Applications A general purpose, 1000 lbs., portable scale utilizing a mechanical beam for industrial and commercial use. mFR# description FBS1124 Portable Beam Scale
webb# 181957
Features & Benefits • 1000 lbs. capacity. • 17.75” X 23.5” platform. • Rugged, cast iron base, lever system and platform are designed for durability. • Easy to read, brass beam insert will not fade in direct sunlight. • Easy to maneuver with built-in wheels. • Conforms to NTEP standards for weighing food, commodities, propane and more.
96
Gas Equipment Catalog
victormfg.com
SECTION
4
Cylinders, Tanks & Accessories
OPD Cylinder Vise Wrench Kit
Cylinder Hand Trucks
The Best Way to Install OPD Cylinder Valves The TTW-3 is a totally new concept in valve wrenches. It quickens installation and removal of QC cylinder valves from DOT containers. The wrench works on all Style 1 (QC) valves, particularly the fixed handwheel OPD’s that are mandated by the DOT for all 5 lbs. to 40 lbs. cylinders. The TTW-3 mates to the cylinder valve QC thread, rather than the POL thread, reducing the possibility of valve deformation when removing or installing. The wrench seats flush against the valve face, distributing torque across a wider area. And the compact TTW-3 fits under the handwheel valve and allows rotation inside the cylinder collar, simplifying the removal and installation procedure.
MFR# VCTTTW-3
Cylinder Hand Truck
Appliance Truck MFR# HPREA6061
4
webb# 182215
webb# 192938 Appliance Truck
Methanol Injector mfr # description VCTTMI-1QL Methanol Injector
webb# 215392
POL Valve Wrench Kit Handle
TMI-1QL Methanol Injector
Hand Held Pump Style
Wrench
mfr# description RIMABJ2 Methanol Injector Hand Held Pump Style
webb# 186594
POL Adapter
MFR# description VCT201 Polished POL Plugs VCT202 Valve Wrench VCT203 Handle 20-3
webb# 184417 184418 184419
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
97
cylinders, Tanks & accessories
The TTW-3 also incorporates a bleed orifice safety feature that will indicate any pressure remaining in the cylinder before removing the valve by simply opening the valve slightly prior to loosening. The wrench is made from tough, durable alloy and forged steel components. This long-lasting construction resists corrosion and distortion.
MFR# description webb# HPR70416 For LP Cylinders 182214 VCTNMP79004P For 420 lbs. Cylinders 190693
SECTION
4
Cylinders, Tanks & Accessories Magnesium Anodes
Pipe Wrap
Magnesium anodes have a 10’ length of #12 electric wire attached. MFR# description
MFR# description
webb#
Anode 17
#17
183403
Anode 5
#5
215998
Typical Tank Anode Requirements
Iron Pipe Anode Requirements
17 lbS. Anodes tank size required 500 gals. 1 1,000 gals. 2 3,000 gals. 4 400 to 5,000 gals. 6 10,000 gals. 8 15,000 gals. 10 20,000 gals. 12 25,000 to 30,000 gals. 14
webb# 243386
KMC4130
Yellow Pipe Wrap, 2” X 100’
PAS9052R
Black Pipe Wrap, 2” X 100’
MISUD21
Underground Gas Detector Tape
183516
VCTTRACER
Tracer Wire 500’ – 14GA
359306
ELE1207PE30-4E Tracer Wire 500’ – 12GA
243218
81161
Typical Small ASME Container Underground Installation
Pipe Pipe size length Install 0ne 5 lbs. Anode 3/4” 500’ 11/4” 450’ 11/2” 425’ 2” 400’ Install 0ne 17 lbs. Anode 3” 700’ 14” 500’ 6” 400’ 8” 350’
Conversion Factors Factors
lbs
1 CU Yard of Concrete
4000
CU ft. of Concrete
148
CU ft. of Water
62.4
1 Gal. of Water
8.345
1 CU Yard of Sand
2400
1 CU Yard of Dirt (Clean Humus or Fill)
3800
500 gal. of water X 8.345 (pounds per gallon) = 4172.5 lbs. of water – tank weight (940#) = 3232.5 pounds of buoyancy to overcome. Pad length and width must be converted to feet in the chart below to have the calculator formula’s to work correctly. Good engineering practice would be to make the pad at least 1 ft. (6 inches on each side) bigger than the container so the stainless anchors only have a direct vertical pull when attached to the stainless coated cable. 3/8” coated cable should provide enough tensile strength to overcome the bouyancy factor.
Tank Buoyancy Chart for Concrete Pad Size quality steel tank size
pad length (min)
Pad width (min)
Weight of tank
tank h20 capacity
buoyancy factor needed to keep in ground
4” pad
6” pad
9” pad
12” pad
120 U/G (5’ 8” L X 24” OD)
5.583
3
260
120
741.4
818.0212
1239.426
1859.139
2478.852
250 U/G (7’ 8” L X 30” OD)
7.666
3.5
480
250
1606.25
1310.426
1985.494
2978.241
3970.988
320 U/G (9’ 6” L X 30” OD)
9.5
3.5
620
320
2050.4
1623.93
2460.5
3690.75
4921
500 U/G (10’ 0” L X 37” OD)
10
4.08
940
500
3232.5
1992.672
3019.2
4528.8
6038.4
1000 U/G (15’ 10” L X 41” OD)
15.833
4.417
1800
1000
6545
3415.594
5175.143
7762.714
10350.29
This calculator is for general reference only. When in doubt have an engineer design a system to your individual job specification and local code requirements.
98
Gas Equipment Catalog
victormfg.com
SECTION
4
Cylinders, Tanks & Accessories
Propane Storage Vessels The withdrawal of propane vapor from a vessel lowers the contained pressure. This causes the liquid to “boil” in an effort to restore the pressure by generating vapor to replace that which was withdrawn. The required “latent heat of vaporization” is surrendered by the liquid and causes the temperature of the liquid to drop as a result of the heat so expended.
Simple formulae for determining the proper number of DOT cylinders and proper size of ASME storage containers for various loads where temperatures may reach 0°F will be found in the sections on 100# DOT Cylinders and ASME Storage tanks respectively
Determining Total Load In order to properly size the storage container, regulator and piping, the total BTU load must be determined. The total load is the sum of all gas usage in the installation. It is arrived at by adding up the BTU input of all appliances in the installation. The BTU input may be obtained from the nameplate on the appliance or from the manufacturers literature. Future appliances which may be installed should also be considered when planning the initial installation to eliminate the need for a later revision of the piping and storage facilities. Where it may be more desirable to have ratings expressed in CFH, divide the total BTU load by 2516 for CFH of propane.
Appliance Range, Free Standing, Domestic Built-in Oven or Broiler, Domestic Built-in Top Unit, Domestic
Approx Input (BTU per Hour) 65,000 25,000 40,000
Water Heater, Quick Recovery, Automatic Storage 30 Gallon Tank 40 Gallon Tank 50 Gallon tank Water Heater, Automatic Instantaneous 2 gal./min. 4 gal./min. 6 gal./min. Refrigerator Clothes Dryer, Domestic Incinerator, Domestic
30,000 38,000 50,000 142,800 285,000 482,000 3,000 20,000 32,000
4
100# DOT Cylinders
“Rule of Thumb” Guide for Installing 100 lb. Cylinders For continuous draws where temperatures may reach zero F. Assume the vaporization rate of a 100 lb. cylinder as approximately 50,000 BTU per hour. Number of Cylinders per side = Total load in BTU’s 50,000 Example: Assume total load = 200,000 BTU/hr. Cylinders per side = 200,000 = 4 cylinders per side. 50,000
Vaporization Rate 100 lbs. Propane Cylinders (approximate) Lbs. of Propane in Cyl. 100 90 80 70 60 50 40 30 20 10
Maximum Continuous Draw in BTU Per Hour at Various Temperatures in Degrees F. 0 113,000 104,000 94,000 83,000 75,000 64,000 55,000 45,000 36,000 28,000
20 167,000 152,000 137,000 122,000 109,000 94,000 79,000 66,000 51,000 38,000
40 214,000 200,000 180,000 160,000 140,000 125,000 105,000 85,000 68,000 49,000
60 277,000 247,000 214,000 199,000 176,000 154,000 131,000 107,000 83,000 60,000
70 300,000 277,000 236,000 214,000 192,000 167,000 141,000 118,000 92,000 66,000
This chart shows the vaporization rate of containers in terms of the temperature of the liquid and the wet surface area of the container. When the temperature is lower or if the container has less liquid in it, the vaporization rate of the container is a lower value. TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
99
cylinders, Tanks & accessories
The heat lost due to the vaporization of the liquid is replaced by the heat in the air surrounding the container. This heat is transferred from the air through the metal surface of the vessel into the liquid. The area of the vessel in contact with vapor is not considered because the heat absorbed by the vapor is negligible. The surface area of the vessel that is bathed in liquid is known as the “wetted surface”. The greater this wetted surface, or in other words the greater the amount of liquid in the vessel, the greater the vaporization capacity of the system. A larger container would have a larger wetted surface area and therefore would have greater vaporization capacity. If the liquid in the vessel receives heat for vaporization from the outside air, the higher the outside air temperature, the higher the vaporization rate of the system. How all this affects the vaporization rate of a 100 lbs. cylinder is shown in a following section (return to contents and see 100# DOT cylinders. You will note that the worst conditions for vaporization rates are when the container has a small amount of liquid in it and the outside air temperature is low.
Approximate BTU Input for Some Common Appliances
SECTION
4
Cylinders, Tanks & Accessories ASME Storage Containers
Determining Propane Vaporization Capacity “Rule of Thumb” Guide for ASME LP-Gas Storage Containers Where D = Outside diameter in inches L = Overall length in inches K = Constant for percent of volume of liquid in container L D
percentage of container filled
k equals
propane vaporization capacity at 00 F (in Btu.hr.)*
60 50 40 30 20 10
100 90 80 70 60 45
D X L X 100 D X L X 90 D X L X 80 D X L X 70 D X L X 60 D X L X 45
* These formulae allow for the temperature of the liquid to refrigerate to -20°F (below zero), producing a temperature differential of 20°F for the transfer of heat from the air to the container’s “wetted” surface and then into the liquid. The vapor space area of the vessel is not considered. Its effect is negligible.
Vaporizing Capacities for Other Air Temperatures Multiply the results obtained with the above formulae by one of the following factors for the prevailing temperature.
100
prevailing air temperature (in degrees f)
-15 -10 -5 0
Gas Equipment Catalog
multiplier
prevailing air temperature (in degrees f)
multiplier
0.25 0.50 0.75 1.00
+5 +10 +15 +20
1.25 1.50 1.75 2.00
victormfg.com
SECTION
4
Cylinders, Tanks & Accessories Quality Steel Replacement Parts
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
ALT. WEBB # 315792
315792
4 cylinders, Tanks & accessories
QS PART # DESCRIPTION MFR # WEBB # ALT. MFR # Tank Size 120 01-001 Filler Valve 7579-T 162745 01-009-1 Float Gauge B8981-1186 HA-130AQ 01-021 Multi Valve, Tube length 6.7 7556-RS 162742 01-007 Relief Valve 7583-GT 162747 01-031 U/G Float Gauge JB-302 315650 Tank Size 150 01-001 Filler Valve 7579-T 162745 01-009-1 Float Gauge B8981-1186 HA-130AQ 01-021 Multi Valve, Tube length 6.7 7556-RS 162742 01-007 Relief Valve 7583-GT 162747 01-008-1 Check Lok 7590-UT 162748 01-031 U/G Float Gauge JB-302 315650 Tank Size 250 01-001 Filler Valve 7579-T 162745 01-010-1 Float Gauge HA 156-AQ 315681 01-023 Multi Valve, Tube length 8.5 7556-RS 162742 01-007 Relief Valve 7583-GT 162747 01-008-1 Check Lok 7590-UT 162748 01-017 U/G Float Gauge, L.N.R. JB350B 315667 JB332BRN 01-045 U/G Float Gauge, S.N.R. JB224B Tank Size 320 01-001 Filler Valve 7579-T 162745 01-010-1 Float Gauge HA 156-AQ 315679 01-023 Multi Valve, Tube length 8.5 7556-RS 162742 01-007 Relief Valve 7583-GT 162749 01-008-1 Check Lok 7590-UT 162748 01-017 U/G Float Gauge, L.N.R. JB350B 315661 JB332BRN 01-045 U/G Float Gauge, S.N.R. JB224B Tank Size 475 01-001 Filler Valve 7579-T 162745 01-011-1 Float Gauge HA 194-AQRN 315679 01-002 Multi Valve, Tube length 10.5 7556-RS 162742 01-012 Relief Valve 8684-GT 162749 01-008-1 Check Lok 7590-UT 162748 01-018 U/G Float Gauge, L.N.R. JB384B 315661 JB370FP-J09 01-046 U/G Float Gauge, S.N.R. JB260C Tank Size 500 01-001 Filler Valve 7579-T 162745 01-011-1 Float Gauge HA 194-AQ 315679 01-002 Multi Valve, Tube length 10.5 7556-RS 162742 01-012 Relief Valve 8684-GT 162749 01-008-1 Check Lok 7590-UT 162748 01-018 U/G Float Gauge, L.N.R. JB384B 315661 JB370FP-J09 01-046 U/G Float Gauge, S.N.R. JB260C Tank Size 1000 01-001 Filler Valve 7579-T 162745 01-016-1 Float Gauge HA 210-AQ 315793 HA210ARN 01-025 Multi Valve, Tube length 11.3 7556-RS 162742 01-013 Relief Valve 8685-GT 162750 01-008-1 Check Lok 7590-UT 162748 01-019 U/G Float Gauge, L.N.R. JB404B 315657 JB386ERN 01-047 U/G Float Gauge, S.N.R. JB280C
315807
315807
315806
315806
315677
315805
101
SECTION
5
Paint & Supplies Premium Industrial Coatings Primers
A single package epoxy primer of high quality that offers excellent corrosion resistance and fast re-coat time. This product is user friendly and offers great coverage. MFR# SUM855G1368 SUM899W1370
description Gray-Green Primer Off White Primer
webb# 184237 184238
Foot Ring Protector Primers
A protective coating that is modified with phenolic resins making this a great product for the bottoms of cylinders. When applied properly, this product aids in corrosion resistance. Can be mopped, brushed or sprayed. MFR#
description
SUM880N2209
Foot Ring Protector, Black
webb# 184248
White Paint Foot Ring Protector
White Paint
Blued White Tank enamel was formulated especially for Propane Tanks offering elasticity, excellent weathering, one coat coverage, and user friendly. Works great with rollers, brushing and also can be sprayed. Silicone Alkyd White is the premium of our Tank Enamels, modified with high percentage of silicone offering excellent gloss and color retention. This product is highly recommended for painting storage tanks when maximized coating life is a must. MFR#
description
SUM880W2203
No. 5 Blued White Tank Enamel
webb# 184244
SUM880W2201
No. 7 Silicone Alkyd White
184249
Aluminum Paint Tank Coating is our most popular aluminum finish that has nearly 2 pounds of aluminum paste in every gallon. SC1000 was formulated using premium blend of oleoresinous varnishes. Strontium Chromate is the premium in our aluminum finishes, all the same great qualities of our SC1000 plus the addition of built in rust inhibitor.
Aluminum Paint
MFR#
description
webb#
SUM880S2205
SC1000 Tank Coating, Aluminum
184233
SUM880S2206
SC1110 Strontium Chromate, Aluminum
184234
SUM880S2207
Aluminum Enamel Paint
184235
Enviro-Tuff Industrial Enamels A high quality industrial enamel offered in an assortment of colors to personalize your tanks. This product is great for many other exterior uses.
Enviro-Tuff Industrial Enamels
MFR#
description
webb#
SUM880G0166
Green Enamel
184182
SUM880L0184
Tan Enamel
184239
SUM885N2100
Black Enamel
184240
SUM880D0130
Mist Gray
184236
SUM885R2108
Red
184241
SUM886Y8625
Industrial Yellow
184245
Paint Thinner
102
MFR#
description
SUM856X2210
XL Thinner
Gas Equipment Catalog
webb# 184251
victormfg.com
SECTION
5
Paint & Supplies Premium Industrial Coatings
(continued)
Coverage Data: Enamels and Primers Tank size (Gallons)
Approx sq. feet
No. 5 blued white
no. 7 sillicone alkyd white
100d8431 hi solids
uni-pox primer 1370 off white
uni-pox primer 1368 gray green
30,000 18,000 12,000 1,000 500 250 Sq. Ft. Coverage per Gal. at 1 dry mil Recommended dft. per coat
1,950 1,250 1,150 225 115 55
7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon
7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon
7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon
7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon
7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon
—
740
760
810
785
785
—
1.5 - 2.5 mils 295 - 495 Sq. Ft.
1.5 - 2.5 mils 305 - 505 Sq. Ft.
1.5 - 2.5 mils 325 - 540 Sq. Ft.
1.5 - 2.5 mils 315 - 520 Sq. Ft.
1.5 - 2.5 mils 315 - 520 Sq. Ft.
The above data is theoretical and may vary slightly from batch to batch and also in dependent on amount of paint actually applied.
Coverage Data: Aluminums and Primers Approx sq. feet
sc 100 aluminum tank covering
sc 1110 strontium chromate
sc 2000 non-glare aluminum
high solids universal primer
epoxy ester primer 1370 off white
30,000 18,000 12,000 1,000 500 250 Sq. Ft. Coverage per Gal. at 1 dry mil Recommended dft. per coat
1,950 1,250 1,150 225 115 55
8 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon
8 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon
7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon
7 Gallons 5 Gallons 4 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon
8 Gallons 6 Gallons 5 Gallons 1 Gallons 2 Tanks Per Gallon 4 Tanks Per Gallon
—
635
665
740
810
615
—
1.5 - 2.5 mils 255 - 425 Sq. Ft.
1.5 - 2.5 mils 265 - 445 Sq. Ft.
1.5 - 2.5 mils 295 - 495 Sq. Ft.
1.5 - 2.5 mils 325 - 540 Sq. Ft.
1.5 - 2.5 mils 250 - 415 Sq. Ft.
The above data is theoretical and may vary slightly from batch to batch and also in dependent on amount of paint actually applied.
Paint Accessories MFR# SUMSC-TTB002 SUMKM-1009 SUMSC-BC003 SUMSC-BG-001 SUMSCL9V14 SUMSC-CR006 SUMSC-TR09K SUMSC-EP03P SUMSC-WB042 SUMSC-CR063
description 12” Trim Brush 5 Gal. Bucket Bucket Cover (3 Per Pkg.) Bucket Grid 9” Lambswool Roller Cover Contour Roller Cover 9” Roller Handle 42” Extension – 3 pc. Pole Wire Brush Contour Roller Complete
webb# 184250 192127 192913 242094 184195 184192 184247 242095 — 264998
Contour Roller Complete Bucket Grid
Wire Brush
12” Trim Brush
Roller Handle
42” Extension
Bucket Cover
Lambswool Roller Cover
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
5 Gallon Bucket
103
5 paint & supplies
Tank size (Gallons)
SECTION
5
Signs/Decals Signs & Decals
Reflective Warning Scotchlite Decals MFR# S22-A S22-B S22-C S29
Updated Test & Retest Kits
description size Railroad Crossing 8” X 36” Railroad Crossing 4” X 36” Railroad Crossing 8” X 12” Railroad Crossing 4” X 36”
webb# — 181431 309162 —
MFR# V31 V32
description size Periodic Inspection Chart 6” X 18” 5 Year Inspection Kit 6” X 18”
webb# — 359351
S22-A S22-B
S22-C
V31
S29
Fuel Signs
Unless otherwise indicated, the items following are red letters on white background. M = Metal (Aluminum) A = 6” letters S = Scotchlite® Brand Reflective B = 4” letters V = Vinyl BB = 3” letters P = Polyethylene (plastic) C = 2” letters D = 1” letters MFR# V72 V288-BB V58 P101 V62 V47
No Smoking Sign
description size webb# Safety First (Blue Only) — — Propane Gas — 192754 LPG (Black On Orange) 21/2” X 3” — Capacity Chart (Red/Blue On Poly) — 260991 Sheet of 10 2# Labels (Black On Yellow) 4” X 51/2” 309285 Propane 9” X 38” 372646
MFR# V49
description size No Smoking Vinyl (Stick-On Decal) 10” X 42”
Placard Holder MFR# MPH69
V32 webb# 188815
V49
description .050 Aluminum With Baked Enamel Finish & Stainless Steel Clip
webb# 181423
V288-BB
CYLINDER FILLING CAPACITY CHART W.C.
LBS. PROPANE
W.C.
LBS. PROPANE
2.39
1
35.8
1
4.78
2
38.2
2
7.17
3
40.6
3
9.56
4
43.0
4
11.9
5
45.4
5
14.3
6
47.8
6
16.7
7
59.7
7
19.1
8
71.7
8
21.5
9
78.8
9
23.9
10
83.6
10
26.2
11
95.6
11
28.6
12
105.1
12
31.0
13
119.5
13
33.4
14
239
14
P101
V47
104
MPH69
D.O.T. Placarding for Bulk Transporters
V58 V72 PROPANE PROPANE PROPANE PROPANE PROPANE PROPANE PROPANE PROPANE PROPANE PROPANE
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
2 2 2 2 2 2 2 2 2 2
P.S.I. P.S.I. P.S.I. P.S.I. P.S.I. P.S.I. P.S.I. P.S.I. P.S.I. P.S.I.
MFR# V1075 P1075 G1075
description Vinyl Polyethylene Magnetic Blanket
webb# 181435 181426 181418
V1075 P1075 G1075
V62
Gas Equipment Catalog
victormfg.com
SECTION
5
Signs/Decals
Signs and Decals (continued) OPD Signs
Storage Tank Diamond for Propane Red, Yellow, Blue & Black on White Vinyl MFR# V704-3 V704-1
description size 300’ Legibility 15” X 15” 100’ Legibility 7.5” X 7.5”
webb# 308184 269724
MFR# P114 P111
description size Retrofit Chart (Blue On White Poly) 18” X 24” Alert Sign (4 Holes & 2 Colors) 16” X 20”
webb# 359348 251721
V704-3 V704-1
Danger Sign MFR# SP53-R
description size Black On Yellow Vinyl 4” X 9”
webb# 181434
P111 P114
Liquid/Vapor Signs
description size Vinyl 11” X 12” Polyethylene 11” X 12” Vinyl 11” X 12” Polyethylene 11” X 12” Black on Yellow Vinyl 2” X 31/2”
webb# 192753 269726 309161 269725 —
V90-5
V91-5
Emergency Signs MFR# V81 P81 V82 P82 11-V-127 11-P-127
V121/P121
webb# — 309284 269723
V90
Filling Procedure Decals MFR# V121 P121 V122 P122 V79
description size Red On White Vinyl 1” X 4” Red On White Vinyl (5 per Sheet) 1” X 4” Red On White Vinyl (5 per Sheet) 1” X 4”
description size Pull – Red On White Vinyl 10” X 12” Pull – Red On White Polyethylene 10” X 12” Push – Red On White Vinyl 10” X 12” Push – Red On White Polyethylene 10” X 12” Red On White Vinyl 12” X 30” Red On White Polyethylene 12” X 30”
webb# — 359350 — 192752 — —
V122/P122 V81/ P81
V82/ P82 11-V-127 11-P-127
V79
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
105
5 paint & supplies
MFR# V90 V90-5 V91-5
SECTION
5
Signs/Decals Signs and Decals (continued) Propane Filling Station Signs
Portable Cylinder Labels MFR# A16 AA16 A53
description size Curved, Black Imprint — Not Curved — Black on White Vinyl 1.5” X 5”
webb# 181416 181417 223683
MFR# M97A M97-AX M97-AD M97-AXD V14 C37 M97-FR
description size webb# Single Faced (Blue On White Aluminum) 2’ X 4’ 181421 Exchange (Blue On White Aluminum) 2’ X 4’ — Double Faced (Blue On White Aluminum) 2’ X 4’ 181413 Exchange (Blue On White Aluminum) 2’ X 4’ — Red & Black On White Vinyl 12” X 16” 309160 Red & Black On Coroplast 12” X 24” — Frame for 2’ X 4’ Signs With Hardware — 181444
A16 (Curved)
AA16
A53
M97A, M97AD
M97AX, M97AXD
Hazard Sign MFR# HZ116
description size Blue, Yellow, Red & Black 21/2” X 5”
webb# 181419
V14
No Smoking While Refueling Decals MFR# V266 V26-A V26-B M26-C
description size Red On White Vinyl 24” X 36” Red On White Vinyl 12” X 18” Red On White Vinyl 12” X 18” Baked Enamel On Aluminum 24” X 36”
C37 webb# — 309159 — 181441
MFR# description MISSIGNDV Direct Vent Appliance Below
VersaPrinter™
webb# 309803
Label Maker
Quickly create any type of label or sign and print as many as you need in a matter of minutes. . . right from your own computer! MFR# B/S42001
106
Gas Equipment Catalog
description Portable Label Pusher
webb# 193975
victormfg.com
SECTION
6
Gauges The “One” Gauge™ Adjustable Liquid-Level Gauge 49S
Application The “One” Gauge™ is a magnetically-coupled liquid-level gauge that adjusts in length and accepts a variety of float stem lengths. This feature makes it easy to quickly and economically replace non-functional gauges in the field for a large variety of tank sizes. They are UL listed. General Information & Features This gauge features a range of adjustable stems which, when mated with an appropriatelength float assembly, enables LP Gas dealers to easily replace the liquid-level gauge in virtually all LP Gas tanks used for domestic storage or mobile applications. Models are available with Junior™ bolted heads in aluminum or brass, Senior™ bolted heads in aluminum, and a version with a Junior™ 11/4” or 1” male NPTF brass head. The design utilizes a square-brass centershaft telescoping inside a square-aluminum pinionshaft, both of which are housed in telescoping aluminum support tubes. An aluminum locknut compresses an aluminum locking sleeve to secure the tubes at the required stem length. All other components are of the same materials as standard Rochester LP Gas gauges. The proper float assembly is attached to the gear housing on the adjustable stem per instructions shown below. Gear Housing Zinc Approvals Gauges are UL listed for LP Gas Service Applications
6 gauges
Materials of Construction Head Aluminum or Brass Drive Magnet Alnico Centershaft Brass Pinionshaft & Support Tubes Aluminum Gears, Cross Stud, & Bearings Stainless Steel
When ordering, specify: 1. Gauge head size ( Jr., Sr., 11/4” NPTF, or 1” NPTF). 2. Aluminum or brass. 3. Tank diameter, shown on nameplate. 4. Mounting location (top, side, end, or angle). 5. If the gauge is angle mounted, state the degree of angle above or below the horizontal centerline, or the distance in inches above or below the horizontal centerline to the center of the gauge opening. 6. If the gauge is end mounted, state the shape of the tank head (hemispherical or semi-ellisoidal). 7. Specify the “H” dimension. This is the distance in inches from the surface of the tank to the top of the mounting surface.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
107
SECTION
6
Gauges Adjustable LP Gas Gauges Jr. Adjustable Gauges—Less Float MFR# 0049s02159bp 0049s02170bp
Description
Webb#
dial
Webb#
359139 361810
5909S02733 5909S02733
184077 184077
Webb#
dial
Webb#
359136 —
5986S02733 5986S02733
184073 184073
Description
Webb#
dial
Webb#
1” - 121/2” to 193/4” Brass Head 1” - 191/2” to 331/4” Brass Head
359137 362437
5909S02733 5909S02733
184077 184077
Jr. 121/2” to 193/4” Brass Head Jr. 191/2” to 331/4” Brass Head
Sr. Adjustable Gauges—Less Float MFR# 0049s02207p 0049s02208p
Description Sr. 121/2” to 193/4” Alum. Head Sr. 191/2” to 331/4” Alum. Head
1” Adjustable Gauges—Less Float MFR# 0049s02160BP 0049s02167BP
11/4” Adjustable Gauges—Less Float MFR#
Description
Webb#
dial
Webb#
11/4” - 121/2” to 193/4” Brass Head 11/4” - 191/2” to 331/4” Brass Head
359138 362436
5909S02733 5909S02733
184077 184077
MFR#
Description
Webb#
6857S11009UP 6857S13759UP 6857S14379UP 6857S17009UP 6857S18509UP
Float 24” Tank ID Float 30” Tank ID Float 32” Tank ID Float 37.5” Tank ID Float 41” Tank ID
359135 359134 359133 359132 361809
Description
Webb#
Jr. Support With 4 Floats
359140
0049s02203BP 0049s02204BP
Float Assemblies
Adjustable Kits MFR# 6287-00001k
108
Gas Equipment Catalog
victormfg.com
SECTION
6
Gauges 6200 Application Junior gauges are supplied standard with 0015-00007 Buna-N gasket and four 0040-00414 zinc-plated steel mounting screws (1/4” — 28 X 7/8”) for attachment to a gauge adapter with 2.03” [51,5] diameter bolt circle (see Rochester Machining Standard MS-501). Models 6281 and 6284 Junior gauges used on above ground ASME storage tanks are equipped with direct reading 5323S01749 percentage dials. Model 6281 Junior gauges used on below ground ASME storage tanks are equipped with direct-reading 5323S01813 percentage dials. Models 6241 and 6244 Junior gauges used on ASME motor fuel tanks are equipped with direct-reading 5323S01789 fractional dials.
Model number = 6244 Support length = 71/2” Tank Diameter = 14” Mfg date = B75 NOTE: Gauge head may also be stamped with model & unique suffix #.
When ordering, specify: 1. Gauge head size, Jr., Sr., or model #. 2. Tank diameter as shown on nameplate. 3. Mounting location (top, side, end or angle). 4. If gauge is angle mounted, state angle. 5. If gauge is end mounted, state the shape of the tank head, hemispherical or semi-ellipsoidal. 6. The “H” dimension, the distance in inches from the surface of the tank to the top of the gauge opening. To order replacement gauge, simply furnish the information stamped on one of the flat sections on the side of the gauge head as shown in the example.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
109
6 gauges
6244 - 71/2”- 14 B75
General Specifications Temperature Range Standard range is -40°F to 158°F, -40°C to 70°C. Accuracy Dependent on proper sizing of gauge and tank configuration. When equipped with Jr.™ dial, overall accuracy is ±5%, Sr.™ dial is ±3%, TwinSite™ sender is ±5%, 4” dial is ±3%. Humidity For high humidity below ground or under chassis applications, brass, stainless steel, or painted aluminum heads are recommended. Shock & Vibration Suitable for mobile service applications. Current 200 mA maximum on TwinSite™ versions. System Voltage 12 to 24 volts on TwinSite™ versions. Working Pressure 375 psi. [25,8 Bar] Approvals Gauges are UL listed for LP Gas service applications.
SECTION
6
Gauges 6300 Series
Application The 6300 Series Magnetel™ liquid-level gauges are designed to accurately determine the percentage of total tank volume for most liquids in stationary-storage applications. UL listed for LP Gas and NH3 service. General Information & Features These Magnetel™ Gauges are available in four basic models: Model 6336 — Incorporates 4” [100 mm] dial and is designed for top mounting. Model 6360 — Incorporates 8” [200 mm] dial and is designed for top mounting. Model 6339 — Incorporates 4” [100 mm] dial and is designed for side, end or angle mounting. Model 6342 — Incorporates an 8” [200 mm] dial and is designed for side, end or angle mounting. The large, easy-to-read dials are also easy to remove and replace. Materials of construction vary depending on the types of liquids to be gauged. Many different optional fea- tures are available to meet your specific needs. These materials and options, along with their pricing impact, are summarized for each model in price list 6300. Magnetel™ gauges are designed for working pressures ranging from atmospheric to 450 [31 Bar] psig.
Ceramic Pointer Magnet Alnico Magnet High and Low Float Arm Stop
99/16” [243] Diameter
140º Float Travel
29/16” [65] From Tank Flange Maximum
Drawing A 4.75” [120] 2” NPT 2.32” [59]
MFR# 0022-00029
3.5” [89]
Drawing B 4.75” [120] 2” NPT 1.93” [49]
3.5” [89]
0022-00525
MATES WITH 6300 Series Y6300 Series Only
TYPE 21/2” NPT 2” NPT sch. 80
material Forged Steel
threads 1/2” - 13 UNC-2B
dimensions
Webb#
Reference dwg A
275098
Reference dwg B
—
When Ordering, Specify: 1. Liquid to be gauged and specific gravity. 2. Inside diameter of tank, head style: ellipsoidal, semi-ellipsoidal or hemispherical. 3. Complete model number desired from price list 6300, (example M6342-11). 4. Prefix letters for available options from price list 6300. 5. If a dial other than standard is required, furnish drawing and/or details. 6. Furnish tank drawings whenever ordering gauges for angle-mounting or for installa tion in vertical tanks. 7. Tank mounting flange, if required (see chart). NOTE: The dimensions of the threaded neck on this adapter are equivalent to Schedule 80 pipe. CAUTION: For LP Gas or NH3 applications requiring 2” NPT connection, specify Y6300 Series Magnetel™ gauges which includes 0022-00525 schedule 80 adapter assembled to gauge.
110
Gas Equipment Catalog
victormfg.com
SECTION
6
Gauges Magnetel™ Rough Rider™ Liquid-Level Gauges M6300
Application The M6300 series Magnetel™ Rough Rider™ gauges were designed to withstand the vibration and shock inherent in mobile service. Their service life in over-the-road and off-road transports, carrying liquids ranging from LP-gas to crude oil, is unsurpassed. These gauges allow a continuous reading between 5% and 95% of tank contents. General Information & Features The Magnetel™ Rough Rider™ gauges are to be installed in the side or end of mobile tanks at the centerline. They are equipped with an exclusive spring controlled shock absorber on the float arm which substantially reduces the stress that quickly destroys conventional gauges. Angle mounting gauges are also available. The M6339 incorporates a 4” [100 mm] dial and the 6342 incorporates an 8” [200 mm] dial. When necessary, the dials are easily replaceable. Refer to price list P6300 for available types, part numbers, etc., as well as other replacement parts and accessories. Price list M6300 includes information on materials of construction, available options, and sales and pricing policy. The Magnetel™ Rough Rider™ gauges are designed for working pressures ranging from atmospheric to 450 [31 Bar] psig.
6
MFR# 0022-00029
MATES WITH
TYPE
material
threads
dimensions
Webb#
6300 Series
21/2” NPT
Forged Steel
1/2” - 13 UNC-2B
Reference dwg A
—
When Ordering, Specify: 1. Liquid to be gauged and specific gravity. 2. Inside diameter of tank heads, ellipsoidal, semi-ellipsoidal or hemispherical. 3. Complete model number desired from price list 6300, (example M6342-11). 4. Prefix letters for available options from price list 6300. 5. If a dial other than standard is required, furnish drawing and/or details. 6. Furnish tank drawings whenever ordering gauges for angle-mounting or for installation in vertical tanks. 7. If tank mounting flange is required, order separately from chart above.
Parts and Adapters MFR#
Rough Rider-Bobtails MFR# CM6339-11-72 CM6339-11-79
dESCRIPTION
Webb#
Magnetel 72” Diameter Tank-4” Dial Magnetel 79” Diameter Tank-4” Dial
275104 275102
0015-00019 0022-00029 5137S01262 0093S00001 0040-00413 0044-00403 0044-00404
dESCRIPTION
Webb#
Gasket-Spiral Wound 21/2” MNPT 31/2” Bold Flange 4” Dial-LPG And NH3 4” Dial Brackets SS 4” Dial Bracket Screws Nut-Magnetel Flange Bolt Magnetel Flange
275100 275098 275125 275129 275135 275134 275130
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
111
gauges
Drawing A
SECTION
6
Gauges
The Eliminator™ Rotogauge Replacement For LP Gas & NH3 Service P6293 Series
Application The Eliminator™ direct-reading float gauge is a direct replacement for 1” NPT rotary-type dip-tube gauges in LP and NH3 storage tanks. These gauges are designed for larger tanks up to 84” [2134mm] in diameter. The Eliminator™ is not intended for use in filling tanks - its use is restricted to tanks with fixed liquid level gauges, used to determine when the maximum fill level has been reached. The eliminator can be used in mobile applications up to 60” [1524mm] in diameter. How To Do The Conversion 1. After the storage tank has been evacuated, remove the rotary gauge from the 1” NPT opening at the centerline of the head. Clean and re-tap the female threads. 2. Remove the 2 screws from the bezel. Put the bezel, screws and dial chamber aside for the moment. Remove the 4 mounting screws holding the gauge head to the adapter. 3. Insert the lower portion of the replacement gauge, including the float bulb, float arm, gear housing and counterbalance, into the tank opening. 4. Apply three wraps of 1/2” [12mm] wide Teflon tape, or other suitable thread sealant, to the 1” NPT threads on the steel adapter through which the gauge support passes. 5. Screw the adapter into the tank opening to achieve a leak-tight joint, and align the gauge mounting holes in the horizontal plane. 6. Using the gasket and four mounting screws supplied, attach the gauge to the adapter fingertight. Be sure the gauge is right side up, the bracket tab for locating dial chamber should be on the right. Torque the mounting screws evenly to 140/150 lbs.in., [16,4Nm] using a cross pattern. 7. Reattach the 4” dial chamber and bezel to the Senior™ gauge head brackets using the two screws supplied. 8. If you end up with the dial chamber upside down, you cannot solve the problem by rotating the bracket. You must rotate the entire gauge 180°. MFR#
MATES WITH
Webb#
Up to 44” 44” - 60” 61” - 72” 73” - 84”
— — — —
P6293-R4400 P6293-R6000 P6293-R7200 P6293-R8400
Special Order
When ordering, specify: 1. Model number. 2. Tank I.D. 3. Shape of the head. Warning: Carefully ensure that gauge and adapter are adequately protected from damage that might cause leakage of tank contents.
112
Gas Equipment Catalog
victormfg.com
SECTION
6
Gauges Magnetic Liquid-Level Gauges for LP Gas Service 7200/B7200
Application The 7200 and B7200 Series Junior™ gauges are identical except the former has a zinc diecast head and the latter has a forged-brass head. Both types have 11/4” Male NPTF threads and 2” [51] hex-wrenching sections and are equipped with direct-reading dials appropriate for the tanks in which they are installed. General Information & Features Model 7281 and B7281 direct-indicating gauges are for top mounting. When used on aboveground ASME, horizontal, domestic storage tanks, they are equipped with 5323S01749 percentage or 5323S01789 fractional dials. When used on tanks buried underground, they are equipped 5323S01813 percentage dials. Most 420# [190 kg] vertical cylinders utilize the 5323S01835 dial. For dials used on other vertical cylinders, contact Rochester. Model 7284 and B7284 gauges are for side, end or angle mounting. When used on ASME motor-fuel tanks they are equipped with 5323S01789 fractional dial. Please contact Rochester for the part numbers of the various dials used on gauges mounted in lift-truck cylinders.
Typical Gauge
When ordering, specify: 1. The tank inside diameter (shown on tank nameplate). 2. The mounting location (top, side, end or angle). 3. If the gauge is angle mounted, state the degree of angle above or below the horizontal centerline. 4. If the gauge is end mounted, state the shape of the tank head (hemispherical or semi-ellipsoidal). 5. The “H” dimension. This is the distance in inches from the surface of the tank to the top of the threaded opening.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
113
6 gauges
General Specifications Temperature Range Standard range is -40°F to 158°F, -40°C to 70°C. Accuracy Dependent on proper sizing of gauge and tank configuration. With direct reading dials, overall accuracy is ±5%; with TwinSite™ Sender, overall accuracy is ±5%. Current TwinSite™ versions, 200 mA. maximum Voltage TwinSite™ versions, 12 and 24 volts. Working Pressure 375 psig [25, 8 Bar]. Approvals Gauges are appropriately UL listed for LP Gas liquid-level service and/or LP Gas automotive accessories.
SECTION
6
Gauges Jr. & Sr. Gauge Installation MS-501/502 Figure A
Figure B
Is the gauge right for your application? Gauges should only be installed in applications recommended by the manufacturer. Verify that the gauge is the proper gauge for your application prior to attempting installation. The float may or may not have a counterbalance depending on the intended application. Applications for light specific gravity liquids or large tanks normally require counterbalancing of the float. The gauge, mounting gasket and mounting adapter (if applicable) must be constructed of materials compatible with the liquid to be measured and the service environ ment. The float, mounting screws and head must be adequately rated for your specific pressure and temperature service. Is the gauge the proper size? As a general rule, the float pivot point should be on the horizontal centerline of the tank when installed. The float length dimension (measured from the float pivot point to the end of the float) should be proportional to the inside tank height and is usually slightly less than 1/2 of the vertical inside height of the tank. Gauges can be constructed for side, top or angle mounting but must be installed in the position for which they are constructed. Hold the gauge by the support (see Figure A) in the intended mounting attitude and operate the float to see if it is correct for your application (see Figure B). CAUTION: Improper gauge or dial selection or application may result in inaccurate readings. Release of tank contents as well as damage to equipment and safety hazard may result if tank is overfilled. Fuel exhaustion may occur if tank contents are less than indicated. LP Gas & NH3 gauge dials require an appropriate temperature chart. WARNING: This gauge is not a substitute for a fixed liquid level gauge or weight measurement device, which may be required for filling. GAUGE REMOVAL WARNING: Should it appear necessary to remove the gauge from the tank, do not attempt removal unless under competent supervision with all due precautions taken against the hazards of released liquid or high pressure and/or flammable gas. HAZARDS: A hazard of fire or explosion may exist if proper methods are not used when removing or installing the gasket. Replace gasket if gauge head is removed. Do not reuse gasket. When reinstalling gauge align head for proper orientation of the float inside tank.
Installation Check color stripe on O.D. of gasket for material. MS – 502 Sr. Gauges
BLUE STRIPE= NEOPRENE. Order Senior™ part # 0015-00836 or Junior™ part # 001500855 recommended for anhydrous ammonia and specific refrigerant applications. RED STRIPE= BUNA-N. Order Senior™ part # 0015-00004 or Junior™ part # 001500007, recommended for specific LP Gas & petroleum applications. BROWN STRIPE = VITON. Order Senior™ part # 0015-00415 or Junior™ part # 0015-00039. WHITE GASKET = TEFLON. Order Senior™ part # 0015-00401 or Junior™ part # 0015-00405. SPIRAL WOUND TEFLON AND STAINLESS STEEL. Order Senior™ part # 0015-00462.
CAUTION: Use spiral wound gasket only with stainless steel gauge head and allen head cap screws.
A. Fit gasket onto gauge boss. B. Carefully insert float into adapter or cou pling and work gauge’s gear housing and support through adapter being careful not to bend or damage them. C. Check to see that gasket is properly sealed in adapter gasket recess. D. Align head for proper orientation of float inside of tank. Torque screws evenly in several steps to the desired torque value. When torquing use a crossing torque pattern.
CAUTION: Do not over torque. Do not re-torque later unless leaking. Over tightening may cause damage to head and gasket. SCREW SIZE DRY TORQUE GASKET TYPE 1/4 – 28 20 TO 50 IN.LBS [2,3 to 5,6 Nm] BUNA, NEOPRENE, VITON, TEFLON 5/16 – 24 30 TO 60 IN.LBS [3,4 to 6,8 Nm] BUNA, NEOPRENE, VITON, TEFLON 5/16 – 24 140 TO 150 IN.LBS [15,8 to 16,9 Nm] SPIRAL WOUND GASKET
114
Gas Equipment Catalog
victormfg.com
SECTION
6
Gauges MS-516
Figure A
These instructions are prepared to assist tradesmen and others generally familiar with liquid storage tank equipment. Consumers are not qualified to perform the installation described below. If you have any questions concerning installation or operation of the gauge, contact Rochester Gauges or one of our authorized distributors for assistance. This document is not instructions for tank filling.
Figure B
An American National Standard Pipe Threads, General Purpose (INCH)
ANSI/ASME B1.20.1-1983 (Varnish threads due to chamfer on die.)
6 MFR# 6281-15.5-30 6281-19.25-37 6281-21-41 6281-89 6281-85
TANK SIZE
Webb#
dial
Webb#
320 Gal-30” Diameter 500 Gal-37.5” Diameter 1000 Gal-41” Diameter 200# Vertical 420# Vertical
275099 275097 275096 275095 184087
5909S02733 5909S02733 5909S02733 5909S02772 5909S02772
184077 184077 184077 275109 275109
TANK SIZE
Webb#
dial
Webb#
320 Gal-30” Diameter 500 Gal-37.5” Diameter 1000 Gal-41” Diameter 200# Vertical 420# Vertical
— — — — 275101
5986S02733 5986S02733 5986S02733 5986S02772 5986S02772
184073 184073 184073 275107 275107
gauges
Jr. flange
Sr. flange MFR# 6280-00630 6280-00637 6280-00641 6280-01235 6280-192
1” NPT MFR# B8981-01232 B8981-1237 B8981-1241 B8981-01235 B8981-2009
11/4” NPT TANK SIZE 320 Gal-30” Diameter 500 Gal-37.5” Diameter 1000 Gal-41” Diameter 200# Vertical 420# Vertical
Webb# — 361808 359343 — 275106
dial
Webb#
5909S02733 5909S02733 5909S02733 5909S02772 5909S02772
184077 184077 184077 275109 275109
MFR# B7281-130 B7281-137 B7281-141 B7281-00388 B7281-00386
TANK SIZE 320 Gal-30” Diameter 500 Gal-37.5” Diameter 1000 Gal-41” Diameter 200# Vertical 420# Vertical
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Webb# 275114 275112 275111 — 372633
dial
Webb#
5909S02733 5909S02733 5909S02733 5909S02772 5909S02772
184077 184077 184077 275109 275109
115
SECTION
6
Gauges Replacing Gaskets 115-793
NOTE: Check color stripe on O.D. of gasket for material.
Senior = 2.06” [52,3] nominal diameter — Junior = 1.56” [39,6] nominal diameter BLUE STRIPE = NEOPRENE RED STRIPE = BUNA-N BROWN STRIPE = VITON WHITE GASKET = TEFLON SPIRAL WOUND TEFLON AND STAINLESS STEEL 5/16 – 24 screw – 30 to 60 In. Lbs., [3,4 to 6,8 Nm] using a crossing pattern. 1/4 – 28 screw – 20 to 50 In. Lbs., [2,3 to 5,6 Nm] using a crossing pattern. #10 screw – 20 to 25 In. Lbs. [2,3 to 2,8 Nm] using a crossing pattern.
Replacement Dials 115-794
Advanced Matrix TwinSite™
Mfr# ROG0040-00414 ROG0040-00415
Description Screw Head, Jr. Screw Head, Sr.
Webb# 184067 184068
ROG0015-00004 ROG0015-00007
Gasket, Sr. Gauge Gasket, Mounting Jr.
184063 184064
ROG5909S02733 ROG5323S01789 ROG5909S02772 RBSRS-228
Dial, Jr. W/5-1749 Dial, Jr. f/331/2 Underground ASME Rep. Remote Level Indicator
184077 184098 275109 314605
R3D Dials-Remote Ready MFR#
Junior™ TwinSite™
5909S02733 5909S02799 5986S02733 5909S02772 5986S02772 5987S02787 5988S02788 5988S02889
Junior™ Direct Reading
dESCRIPTION
Webb#
Jr. ASME Above Ground Jr. ASME Under Ground Sr. AMSE Above Ground Jr. 10-82% Vertical 200/420’S Sr. 10-82% Vertical 200/420’S JY Taylor Style A JY Taylor Style B Jr. Taylor Vertical 420’S Style B
184077 275108 184073 275109 275107 273836 275105 359345
Jr. Dials-Direct Read MFR# 5323S01789 5714S02591 5364S01951 5AAAS02772
116
Screws and Gaskets
dESCRIPTION
Webb#
Jr. Fractional 33 1/3# Snap On 33 1/3# Snap On 200/420’s No Remote Snap On 200/420’s With Remote
184098 283967 184082 415723
Gas Equipment Catalog
MFR# 0015-00004 0015-00007 0040-00414 0040-00415 0040-00675
dESCRIPTION
Webb#
Sr. Gasket Jr. Gasket Jr. Screw Sr. Screw Jr. Screw For Brass Head
184063 184064 184067 184068 372635
victormfg.com
SECTION
6
Gauges Pressure Gauges Mfr# description webb# 21/2” Dial, 1/4” Brass Lower Mount, ABS Case ASH95449 0-30” w.c.
173954
SJIGGAUGE
0-5 PSI
84202
PROP15
0-15 PSI
36483
PROP30
0-30 PSI
36484
PROP60
0-60 PSI
36485
PROP100
0-100 PSI
36486
PROP160
0-160 PSI
36487
PROP200
0-200 PSI
36488
PROP300
0-300 PSI
36489
ASH10256
0-30 PSI
36490
ASH15039
0-600 PSI
36491
ASH14223
0-1000 PSI
36492
21/2” Dial, 1/4” Brass Back Mount, ABS Case ASH00165 0-30 PSI
77875
ASH00166
0-60 PSI
77876
ASH00167
0-100 PSI
77877
ASH00168
0-160 PSI
77878
ASH00169
0-200 PSI
176518 36496
ASH00260
0-30 PSI
36497
ASH00261
0-60 PSI
36498
ASH00262
0-100 PSI
36499
ASH00263
0-160 PSI
36500
ASH00264
0-200 PSI
36501
ASH14143
0-300 PSI
36502
21/2” Liquid Filled Dial, 1/4” Brass Lower Mount, ABS Case ASH00511 0-15 PSI
110914
ASH00512
0-30 PSI
110915
ASH00513
0-60 PSI
110916
ASH00509
0-100 PSI
110917
ASH00514
0-160 PSI
110918
ASH00515
0-200 PSI
110919
ASH00516
0-300 PSI
110920
ASH00517
0-400 PSI
110921
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
6 gauges
4” Dial, 1/4” Brass Lower Mount, ABS Case ASH12194 0-15 PSI
117
SECTION
7
Gas Pipe, Tubing & Fittings Flexible Gas Tubing MFR#
Size
Pkg. Qty webb#
Corrugated Stainless Steel 300 Series With Polyethylene Jacket TRP-SS4-375-100 3/8” 100’ Reel 216967 TRP-SS4-375-250
3/8”
250’ Reel
216966
TRPSS4-500-50
1/2”
50’ Reel
250002
TRP-SS4-500-100
1/2”
100’ Reel
219618
TRP-SS4-500-250
1/2”
250’ Reel
87389
TRPSS4-750-50
3/4”
50’ Reel
250003
TRP-SS4-750-100
3/4”
100’ Reel
219619
TRP-SS4-750-250
3/4”
250’ Reel
87390
TRPSS4-100-50
1”
50’ Reel
250001
TRP-SS4-100-180
1”
180’ Reel
87391
TRPSS4-125-50
11/4”
50’ Reel
250000
TRP-SS4-125-150
11/4”
150’ Reel
205453
TRP-SS4-150-150
11/2”
150’ Reel
219620
TRP-SS4-200-150
2”
150’ Reel
219621
Description/Dimensions
MFR# Size (inch) EDH (AGA Size)* Jacket O.D. (max.) Inside Diameter (nom.) Wall Thickness (in.)
SS4-375 3/8” 15 .668 .440 .01
SS4-500 1/2” 19 .868 .597 .01
SS4-750 3/4” 25 1108 820 .01
SS4-100 1” 31 1.38 1.040 .01
SS4-125 11/4” 37 1665 1290 .012
SS4-150 11/2” 46 1920 1525 .012
SS4-200 2” 62 2590 2060 .012
* EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity. This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.
Underground TracPipe
118
MFR#
Size
Pkg. Qty webb#
TRPUG375-100 TRPUG500-100 TRPUG750-100 TRPUG100-100 TRPUG125-100 TRPUG125-200 TRPUG150-100 TRPUG150-200 TRPUG200-200
3/8”
100’ Coil 100’ Coil 100’ Coil 100’ Coil 100’ Coil 200’ Coil 100’ Coil 200’ Coil 200’ Coil
1/2” 3/4”
1” 11/4” 11/4” 11/2” 11/2” 2”
Gas Equipment Catalog
216985 216986 216987 216988 216989 241888 S720800 242755 242756
victormfg.com
SECTION
7
Gas Pipe, Tubing & Fittings Counterstrike Tubing MFR# trpcs-375-250 trpcs-500-100 trpcs-500-250 trpcs-750-100 trPcs-750-250 trpcs-100-180 trpcs-125-150 trpcs-150-150 trpcs-200-150
tubing size
pkg. qty
Webb#
3/8”
250’ Reel 100’ Reel 250’ Reel 100’ Reel 250’ Reel 180’ Reel 150’ Reel 150’ Reel 150’ Reel
368348 368349 368160 368350 368159 368344 368345 368346 368347
1/2” 1/2” 3/4” 3/4”
1” 11/4” 11/2” 2”
Installation Bulletin for CounterStrike® CounterStrike® Installation Instructions for all products date coded 0731 and higher (manufactured after July 30, 2007). CounterStrike CSST with the black, protective sleeve uses the same easy to install AutoFlare® fittings as conventional TracPipe® with the yellow jacket. CounterStrike systems are sized in the same manners as TracPipe either using Capacity Tables or other approved methods.
2.
The instructions for cutting the tubing and for making fitting connections to CounterStrike are identical to standard yellow-jacketed TracPipe. The Jacket shall remain intact as much as practical when attaching the fitting.
3.
There are no special installation requirements for CounterStrike date coded 0731 and higher. The bonding requirements for CounterStrike are per National Electrical Code NFPA 70 Article 250.104 and the National Fuel Gas Code NFPA 54. No additional bonding is required.
4.
CounterStrike date coded 0731 and higher meets building code requirements (ASTM E84) with respect to flame spread and smoke density. This permits installation in drop ceilings used as return air plenums.
5.
CounterStrike date coded 0731 and higher has thru penetration UL classifications for 1, 2 and 4 hours with the black jacket intake.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
7 gas pipe, tubing & fittings
1.
119
SECTION
7
Gas Pipe, Tubing & Fittings AutoFlare Fittings ®
Brass Fitting AutoFlare Insert
Straight Mechanical Fittings, Reducing Fittings
Straight Fitting
Reducing Fitting
MFR# type
Size pkg. qty.
TRP-FST-375 TRP-FST-500 TRP-FST-750 TRP-RST750-500 TRP-FST-1000 TRP-RST1000-750 TRP-FST-1250 TRP-FST-1500 TRP-FST-2000
3/8” (1/2” NPT)
Straight Straight Straight Reducing Straight Reducing Straight Straight Straight
1/2” 3/4”
3/4” - 1/2” NPT
1” 1” - 3/4” NPT 11/4” 11/2” 2”
webb# 216968 87393 87394 219624 87395 219625 205454 219622 219623
24/box 24/box 16/box 16/box 16/box 16/box 6/box 4/box 4/box
Termination Mount, Meter Termination MFR# type pkg. qty. Size Termination Mount
90° Termination Mount
Meter Termination
Flange Mount Fitting
TRP-TM-375 TRP-TM-500 TRP-TM-750 TRP-TM-1000 TRP-90TM-375 TRP-90TM-500 TRP-MT6-500 TRP-MT12-500 TRPMT6-750
Termination Mount Termination Mount Termination Mount Termination Mount 90° Termination Mount 90° Termination Mount 6” Meter Termination 12” Meter Termination 6” Meter Termination
12/Box 12/Box 8/Box 8/Box 8/Box 8/Box 1 ea. 1 ea. 1 ea.
3/8”
Flange Fittings TRP-BFF-375 TRP-BFF-500 TRP-BFF-750 TRP-BFF-1000 TRP-BFF-1250 TRP-TERM-BRAC TRP-ELLS-375 TRPFGP-ELLS-500
Iron Flange Brass Iron Flange Brass Iron Flange Mount Brass Iron Flange Mount Brass Iron Flange Mount Brass Flange Bracket 90° Elbow Flange Mount 90° Elbow Flange Mount
12/box 12/box 8/box 8/box 4/box 1 ea. 8/box 8/box
3/8”
webb# 217405 217406 217407 219626 217401 217402 246855 246856 250428
1/2” 3/4”
1”
3/8” 1/2” 1/2” 1/2” 3/4”
1/2”
3/4” 1” 11/4” All 3/8” 1/2”
Grounding Clamps VCTC11N 1/2”, 3/4” 1” VCTC22 11/4” - 2” 90° Elbow Flange Mount
372312 372313
Mounting Bracket
TracPipe by Pipe Outlet
TracPipe by TracPipe Outlet MFR# type
Size
Pkg. Qty webb#
TRP-TF500-T500 TRP-TF750-T750 TRP-TF1000T1000 TRP-TF750-T500 TRP-TF1000-T500 TRP-CPLG-375 TRP-CPLG-500 TRP-CPLG-750 TRP-CPLG-1000
1/2” X 1/2”
14/box 12/box 10/box — — 24/box 24/box 16/box 16/box
120
216975 87398 87399 87376 216976 222077 216981 216982
Tee Tee Tee Tee Tee Coupling Coupling Coupling Coupling
3/4” X 3/4”
1” X 1”
1/2” X 3/4”
1” X 3/4” 3/8” 1/2” 3/4” 1”
Gas Equipment Catalog
260025 222079 263584 222081 222082 216977 216978 216979 216980
MFR# type
Size
TRPT500-500 TRPT750-750 TRPT750-500 TRPT1000-1000
1/2” FIP
Tee
Tee Tee Tee Tee
Coupling
3/4” FIP
3/4” X 1/2” FIP
1” FIP
webb# 222078 222084 308740 222080
TracPipe by Pipe Outlet Tee
victormfg.com
SECTION
7
Gas Pipe, Tubing & Fittings Accessories Spare Split Rings
Full Striker Plate
MFR#
Size
webb#
TRPRING-375 TRPRING-500 TRPRING-750
3/8” Spare 1/2” Spare 3/4” Spare
222083 242572 247210
Striker Plates Half Striker Quarter Striker
MFR#
Description
Size
TRPSP-025 TRPSP-050 TRPSP-100 TRPFGP-SF-617
Quarter Striker Plate Half Striker Plate Full Striker Large Plate
3” X 2” 500/box 3” X 7” 100/box 3” X 12” 50/box 61/2” X 17”
Pkg. Qty
webb# 87381 87380 87379 276535
Floppy Galvanized Steel Conduit Floppy Strip Wound Conduit
Coated Manifold
MFR#
Description Size
Pkg. Qty
TRPFPY-375 TRPFGP-FPY-500 TRPFGP-FPY-750 TRPFGP-FPY-1000 TRPFPY-1250 TRPFPY-1500
Floppy Fits 3/8” Floppy Fits 1/2” Floppy Fits 3/4” Floppy Fits 1” Floppy Fits 11/4” Floppy Fits 2”
50’ Coil 50’ Coil 25’ Coil 25’ Coil 25’ Coil 25’ Coil
3/4”
1” 11/4” 11/2” 2” 21/2”
webb# 216969 216970 216971 216972 205456 216973
Manifolds
Manifold Bracket
Description
Size
Pkg. Qty
TRP-MI-PC TRP-MB2 TRPTERM-BRAC TRPP-LC TRPFGP-MI-PC-1X
Coated Manifold Manifold Bracket Flange L Bracket Load Center With Bracket Coated Manifold
3/4” X 1/2” X 1/2” (4)
1 ea. 1 ea. 1 ea. 1 ea. 1 ea.
* * * 11/4” X 1” X 3/4” (4)
Vent Tees
(Use when required by local codes)
(Two required for each run)
Vent Tees
246854 217403 222077 216983 256174
Underground TracPipe Accessories Shrink Cuffs
Shrink Cuffs
webb#
MFR# TRPHST-12 TRPHST-34 TRPHST-1 TRPHST-300 TRPHST-350-6 TRPHST-2
Size 1/2” 3/4” 1” 11/4” 11/2” 2”
MFR# TRPVT-125 TRPVT-150 TRPVT-200
webb# 216991 216992 216993 216994 242757 242758
Size webb# 3/8” and 1/2” 216996 3/4” and 1” 216997 242759 11/4”
Pipe Wrap
TracPipe Tools
Tube Cutter
MFR#
Desc.
TRPTC-151 TRPTC-152
Tube Cutter for 3/8” – 11/4” Tube Cutter for 11/4” – 2”
TracPipe Pipe Wrap webb# 205455 216984
MFR#
Desc.
TRP915-10H-12
Yellow Outdoor
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
7 gas pipe, tubing & fittings
Load Center With Bracket
MFR#
webb# 242814
121
SECTION
7
Gas Pipe, Tubing & Fittings Coated Copper Tubing For Natural Gas and Liquefied Petroleum Gas Copper has proven to be reliable and economical source for interior natural gas and liquefied petroleum installations for over 25 years. It’s use has introduced vertical subdivision concepts, individual metering and new add-on markets. Copper’s demand ranges from single-family dwellings to row houses to multi-story apartments. Within these dwellings, gas can be a source for furnaces, room heaters, air conditioning units, gas-fired heating boilers and domestic hot water heaters. Gas also economizes the use of cooking ranges, clothes dryers, gas fireplaces, gas barbeques and decorative gas lamps. mfr# size webb# General Purpose, Yellow Coating 190668 KMCPC38OD50 3/8” X 50” 190669 KMCPC12OD50 1/2” X 50” 190670 KMCPC58OD50 5/8” X 50” 190671 KMCPC380D100 3/8” X 100” 190672 KMCPC120D100 1/2” X 100” 190673 KMCPC580D100 5/8” X 100” 191023 KMCPC380D250 3/8” X 250” 191024 KMCPC120D250 1/2” X 250” 245837 KMCPC580D250 5/8” X 250” Oil Tech, Orange Coating KMC38X50CTD 3/8” X 50” 1/2” X 50” KMC12X50CTD KMC38X100CTD 3/8” X 100” KMC12X100CTD 1/2” X 100”
201445 213315 201446 213316
Type “L” KMCPC38L60 KMCPC12L60 KMCPC58L60 KMCPC38L100 KMCPC12L100
190674 190675 190676 191820 191821
3/8” X 60” 1/2” X 60” 5/8” X 60”
3/8” X 100” 1/2” X 100”
Can Gas-Tec be used underground? Yes, our material can be direct buried. In Canada, Gas-Tec G/Gas is currently the only tubing that can be used both above and below ground without any modification. In the United States, most areas allow Gas-Tec Refrigeration grade or Type “L” tubing to be buried, but we recommend our Gas-Tec type “L” (G/Gas) due to the heavier wall thickness on most sizes.
Standard Copper Tubing MFR #
Type L-G/Gas, ASTM B88/B837 nominal outside wall standard size diameter thickness lengths* 1/4” L
3/8” G/Gas
1/2”L
5/8” G/Gas
3/8”L 5/8”L 3/4”L
.030” .035” .040” .042” .045”
1/2” G/Gas 3/4” G/Gas 7/8” G/Gas
30’ 60’ 100’ 250’ 30’ 60’ 100’ 250’ 30’ 60’ 100’ 250’ 30’ 60’ 100’ 30’ 60’ 100’
* Custom sizes available upon request
General Purpose, ASTM B68/B280 Refrigeration outside wall standard diameter thickness lengths* 3/8” 1/2” 5/8”
122
.032” .032” .035”
Safer Installation for Gas Easy to Identify • Permanent yellow polyethylene coating. • Continuous line marking. • Traceable back to origin of manufacturing. • Mill test reports available upon request. Easy to Install • No additional training required for installation. • Flexible • Easy to join • Compact size • Requires smaller and fewer tools than steel pipe. • Cleaner than threaded steel pipe. Cost Efficient • Most economical line-marked tubing on the market. • Minimal labor costs due to quick and easy installation. • No on-site sleeving required for underground gas lines. Recyclable • Copper is fully recyclable.
25’ 50’ 100’ 250’ 25’ 50’ 100’ 250’ 25’ 50’ 100’ 250’
Gas Equipment Catalog
SIZE LENGTH WEBB#
refrigeration tubing C/T38OD 3/8 50 C/T38OD100 3/8 100 C/T12OD 1/2 50 C/T12OD100 1/2 100 C/T58OD 5/8 50 C/T58OD100 5/8 100 K Tubing C/T38K60 3/8 60 C/T38K100 3/8 100 C/T12K60 1/2 60 C/T12K100 1/2 100 C/T58K60 5/8 60 L Tubing C/T38L60 3/8 60 C/T38L100 3/8 100 C/T12L60 1/2 60 C/T12L100 1/2 100
2582 58835 2583 58836 2584 58837 2526 191720 2539 150326 111921 2552 190614 2553 91639
victormfg.com
SECTION
7
Gas Pipe, Tubing & Fittings Gates Bulk Hose Spiral Reinforced
Series 7132 LP Gas Hose
Features a smooth, abrasion resistant cover and the flexibility of the 4 spiral reinforcements result in a hose that is easier to handle and glides smoothly over any surface. • Tube: Black Nitrile. • Cover: Perforated Black Neoprene. • Reinforcement: Multiple Textile Braids. • Temp. Range: -50°F to 180°F.
Underground PE Gas Pipe MFR#
SIZE WEBB# 378760 193140 319632 193141 183524 165738 165739 165740 183399 165571 263102 165741 165742 183429 183525 165572 165743 165744 183430 165573 165745 165746 183431
mfr# HFBLP350X34X1FT HFBLP350X34X3FT HFBLP350X34X12FT HFBLP350X34X18FT HFBLP350X34X20FT HFBLP350X34X50FT HFBLP350X1X15FT HFBLP350X1X100FT HFBLP350X1X150FT
DESC. Webb# 3/4” X 1 FT 438652 3/4” X 3 FT 438653 3/4” X 12 FT 438654 3/4” X 18 FT 438655 3/4” X 20 FT 438656 3/4” X 50 FT 438657 1” X 15 FT 438658 1” X 100FT 438659 1” X 150 FT 438660
Drip Leg Packages mfr# size Webb# 3/8” X 3” 184977 DLKDL6-3 1/2” X 3” 184978 DLKDL8-3 1/2” X 6” 184979 DLKDL8-6 3/4” X 3” 184975 DLKDL12-3 3/4” X 6” 184976 DLKDL12-6
7 gas pipe, tubing & fittings
YGP12CTS090-75 1/2 CTS X 75’ YGP12CTS090-100 1/2 CTS X 100’ YGP12CTS090-150 1/2 CTS X 150’ YGP12CTS090-200 1/2 CTS X 200’ YGP12CTS090-500 1/2 CTS X 500’ YGP12SDR93-100 1/2 IPS X 100’ YGP12SDR93-150 1/2 IPS X 150’ YGP12SDR93-200 1/2 IPS X 200’ YGP12SDR93-500 1/2 IPS X 500’ YGP34SDR11-50 3/4 IPS X 50’ YGP34SDR11-75 3/4 IPS X 75’ YGP34SDR11-100 3/4 IPS X 100’ YGP34SDR11-150 3/4 IPS X 150’ YGP34SDR11-500 3/4 IPS X 500’ YGP1CTS099-500 1 CTS X 500’ YGP1SDR11-100 1 IPS X 100’ GP1SDR11-150 1 IPS X 150’ YGP1SDR11-200 1 IPS X 200’ YGP1SDR11-500 1 IPS X 500’ YGP114SDR11-100 1-1/4 IPS X 100’ YGP114SDR11-150 1-1/4 IPS X 150’ YGP114SDR11-200 1-1/4 IPS X 200’ YGP114SDR11-500 1-1/4 IPS X 500’ YGP112SDR11-150 1-1/2 IPS X 150’ YGP112SDR11-500 1-1/2 IPS X 500’ YGP2SDR11-100 2 IPS X 100’ YGP2SDR11-200 2 IPS X 200’ YGP2SDR11-500 2 IPS X 500’
Certified & Tested
In-Line Trap mfr# Description Webb# VCT93UT-08 In-Line Low 361067 Pressure Sediment Trap
165575 183432 165749 165751 183433
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
123
SECTION
7
Gas Pipe, Tubing & Fittings R.W. Lyall Propane Piping Systems Lower Installation Costs — Fewer Repairs Over Time
The LYCOFIT® connection system by Lyall, which requires no pipe preparation or special training, is much easier and faster to install compared to other mechanical fittings, electrofusion, and thermal fusion methods. Even more important is that installation failures due to bad pipe cuts, poor fusion, and weak connections are eliminated in the process. Add to that the durability of Lyall chemically resistant fittings and you will no longer have to concern yourself with re-installation due to typical joint failures.
Residential Application
Lyall provides a wide variety of product sizes and configuration to meet residential needs. ®
LYCOFIT Mechanical Fittings
• 100% leak-proof, easy to install • Cost effective, maintenance free joining system • Unprecedented performance levels and proven reliability • Excellent durability resistant to harsh chemicals and cracking • Simple installation, no fusion equipment required • No measuring or calculating required • Absolutely no slippage or pull-out
124
LYCOFIT® is a mechanical fitting for connecting underground Polyethylene (PE) gas piping systems. Lyall offers over 900 configurations allowing for varied installation requirements. Patented 100% Leak-Proof Design The LYCOFIT® fitting takes advantage of the natural sealing properties of the PE pipe, in a superior patented design that uses a barbed spigot to seal the inside diameter (ID) of the PE gas pipe, and a completion sleeve that provides the force necessary for a leak-proof, reliable connection every time. By using the polyethylene as the gasket material, this assures a positive seal between the coupling and the pipe regardless of the outside condition of the pipe. The system eliminates the use of O-rings and rubber gaskets that could leak on scratched pipe or deteriorate under adverse conditions like exposure to chemicals. Compact LYCOFIT® designs allow for installation in confined spaces.
Eliminates Pull-Out The design provides a connection so strong that it provided enough gripping power to eliminate pull-out 100% of the time. In ASTM Quick Burst and Tensile Testing, PE Pipe fails before the LYCOFIT® coupling every time! Instant Visual Check LYCOFIT® provides the installer with a full visual quality check — first “pipe-on” and the “sleeve on” in each installation for a gas tight connection.
Gas Equipment Catalog
victormfg.com
SECTION
7
Gas Pipe, Tubing & Fittings
R.W. Lyall Propane Piping Systems (continued) LYCOFIT® Mechanical Fittings mfr# description PE Pipe to Copper Tube Adapter LYCLC375010B-GCR 3/8” O.D. Flare X 1/2” CTS LYCLC500010B-GCR 1/2” O.D. Flare X 1/2” CTS
webb#
179091 179093
Double End Couplings
LYCLC010B-DER LYCLC030B-DER LYCLC030D-DER LYCLC050W-DER LYCLC060Y-DER LYCLC070Y-DER LYCLC080X-DESR LYCLC090Y-DESR LYCLC200Y-DESR
1/2” CTS 1” CTS 1” CTS 1/2” IPS 3/4” IPS 1” IPS 11/4” IPS 11/2” IPS 2” IPS
183448 179004 179005 183453 183449 183450 183451 179012 183452
Stop & Go Couplings
LYCLC010B-SGR LYCLC050W-SGR LYCLC060Y-SGR
1/2” CTS 1/2” IPS 3/4” IPS
179025 179027 179028
Reducer Couplings
1” CTS X 1/2” CTS 1” CTS X 3/4” IPS 11/4” CTS X 1/2” CTS 1/2” IPS X 1/2” CTS 3/4” IPS X 1/2” CTS 3/4” IPS X 1/2” IPS 1” IPS X 1/2” CTS 1” IPS X 1/2” IPS 1” IPS X 3/4” IPS 1” IPS X 1” CTS 11/4” IPS X 3/4” IPS 11/2” IPS X 3/4” IPS 11/2” IPS X 1” IPS 2” IPS X 1” IPS 2” IPS X 11/4” IPS 2” IPS X 11/2” IPS 2” IPS X 3/4” IPS
179066 179068 179069 179073 193507 179074 179077 183465 179080 179081 359260 359259 359261 360328 179084 355654 359262
LYCLC010B-3TR LYCLC030B-3TR LYCLC050W-3TR LYCLC060Y-3TR LYCLC070Y-3TR LYCLC080X-3TR LYCLC200Y-3TR
1/2” CTS 1” CTS 1/2” IPS 3/4” IPS 1” IPS 11/4” IPS 2” IPS
179029 179031 183470 183467 179037 183520 183469
1/2” IPS 1/2” CTS
1” CTS 3/4” IPS 1” IPS 11/4” IPS 2” IPS
183462 179040 179042 183458 183459 183460 183461
11/4” IPS 2” IPS
179086 179087
1/2” CTS 1/2” IPS 3/4” IPS
179014 183457 179021 183455 179023 179024
90° Elbow Couplings
LYCLC050W-ELR LYCLC010B-ELR LYCLC030B-ELR LYCLC060Y-ELR LYCLC070Y-ELR LYCLC080X-ELR LC200Y-ELR Repair Couplings LYCLC080X-DER LYCLC200Y-DER End Caps
LYCLC010B-ECR LYCLC050W-ECR LYCLC060Y-ECR LYCLC070Y-ECR LYCLC080X-ECR LYCLC200Y-ECR
1” IPS 11/4” IPS 2” IPS
Steel Pipe to PE Pipe Transitions
Reducing Tees LYCLC050W050W010BR LYCLC020B020B010BR LYCLC070Y070Y10BR LYCLC070Y070Y60YR LYCLC080X080X030BR LYCLC060Y060Y010BR
1/2” IPS X 1/2” IPS X 1/2” CTS 3/4” X 3/4” X 1/2” CTS 1” X 1” IPS X 1/2” CTS 1” X 1” IPS X 3/4” IPS 11/4” X 11/4” IPS X 1” CTS 3/4” CTS X 3/4” IPS X 1/2” CTS
202396 194154 194161 194164 194169 202397
LYCLC050S050W-SPB 1/2” NPT X 1/2” IPS LYCLC060S060YSPB 3/4” NPT X 3/4” IPS LYCLC070S070YSPB 1” NPT X 1” IPS LYCLC080S080XSPB 11/4” NPT X 11/4” IPS LYCLC200S200YSPB 2” NPT X 2” IPS
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
274130 183510 183511 183512 179062
125
7 gas pipe, tubing & fittings
LYCLC030D010B-RR LYCLC030D060Y-RR LYCLC040B010B-RR LYCLC050W010B-RR LYCLC060Y010B-RR LYCLC060Y050W-RR LYCLC070Y010B-RR LYCLC070Y050W-RR LYCLC070Y060Y-RR LYCLC070Y030B-RR LYCLC080X060Y-RR LYCLC090Y060Y-RR LYCLC090Y070Y-RR LYCLC200Y070Y-RR LYCLC200Y080X-RR LYCLC200Y090Y-RR LYCLC200Y060Y-RR
mfr# description Webb# 3-Way Tee Couplings
SECTION
7
Gas Pipe, Tubing & Fittings R.W. Lyall Propane Piping Systems (continued) Lyall Risers
Chamfer Tools mfr# description LYC0000-33-5647-00 Chamfer Tool 1/2” IPS X 1/2” CT LYC0000-33-5481-00 Chamfer Tool 3/4” IPS X 1/2” CTS LYC0000-33-5516-00 Chamfer Tool 1” IPS X 3/4” IPS LYC0000-33-6580-10 Chamfer Tool 11/4” IPS LYC0000-33-6580-16 Chamfer Tool 11/2” IPS LYC0000-33-6580-17 Chamfer Tool 2” IPS
webb# 269235 269231 269234 371813 269646 371809
LYCOFIT® Mechanical Tapping Tees mfr# description Mechanical Tapping Tees
LC080010B-TTR LC080030D-TTR LC080070Y-TTR LC200010B-TTR LC200050W-TTR LC200060Y-TT
11/4” IPS X 1/2” CTS 11/4” IPS X 1” CTS 11/4” IPS X 1” IPS 2” IPS X 1/2” CTS 2” IPS X 1/2” IPS 2” IPS X 3/4” IPS
webb#
179131 179133 179143 198639 179154 355653
Test Cap, Mechanical Tapping Tees LCTESTCAP Fits All Lyall Mechanical Tapping Tees Wrench, “T” Handled LYCLCT
LYCSTDLY050010T LYCSTDLY060010T LYCSTDLY060050T LYCSTDLY060060T LYCSTDLY070010T LYCSTDLY070030T LYCSTDLY070050T LYCSTDLY070060T LYCSTDLY070070T LYCKPLGS080080C-T LYCSTDLY090090T LYCSTDLY200200T
1/2” NPT X 1/2” CTS 3/4” NPT X 1/2” CTS 3/4” NPT X 1/2” IPS 3/4” NPT X 3/4” IPS 1” NPT X 1/2” CTS
1” NPT X 1” CTS 1” NPT X 1/2” IPS 1” NPT X 3/4” IPS 1” NPT X 1” IPS 11/4” NPT X 11/4” IPS 11/2” NPT X 11/2” IPS 2” NPT X 2” IPS
193302 192989 180062 180063 193893 193894 193895 193896 183406 370409 193897 193898
3/4” NPT X 1/2” CTS 3/4” NPT X 1/2” IPS 3/4” NPT X 3/4” IPS 1” NPT X 1/2” CTS 1” NPT X 1/2” IPS 1” NPT X 3/4” IPS
192494 192628 192630 192631 192632 192634
Anodeless Flexible Riser LYCSTDLY060010FXT LYCSTDLY060050FXT LYCSTDLY060060FXT LYCSTDLY070010FXT LYCSTDLY070050FXT LYCSTDLY070060FXT
Anodeless LPG Flexible Tank Risers
For Lycofit® Mechanical Tapping Tee Cutter
Transition Fittings mfr# description Threaded Steel End
mfr# description Webb# Anodeless 90° Bend Rigid Riser
webb#
LYCSTDLY050010FXPGS LYCSTDLY050050FXPGS LYCSTDLY060060FXPGL
1/2” NPT X 1/2” CTS Short 1/2” NPT X 1/2” IPS Short 3/4” NPT X 3/4” NPT Long
252451 252452 252456
Service Head Risers— No Coupling Required LYCLT050S010B-BT LYCLT050S050W-BT LYCLT060S060Y-BT LYCLT070S030B-BT LYCLT070S070Y-BT LYCLT080S080Y-BT LYCLT090S090Y-BT LYCLT200S200Y-BT
1/2” NPT X 1/2” CTS 1/2” NPT X 1/2” IPS 3/4” NPT X 3/4” IPS
1” NPT X 1” CTS 1” NPT X 1” IPS 11/4” NPT X 11/4” IPS SDR11 11/2” NPT X 11/2” IPS 2” NPT X 2” IPS
263208 283833 198865 202405 198870 215554 202399 202400
Lyall Polyethylene Ball Valves Available through special order: Sizes , 1/2” CTS — 2” IPS
126
Gas Equipment Catalog
mfr# description Webb# lycshafc050010b-36 36” 1/2” npt x 1/2” cts 261875 36” 1/2” npt x 1/2” ips 261876 LYCSHAFC050050W-36 LYCSHAFC060010B-36 36” 3/4” npt x 1/2” cts 261877 LYCSHAFC060050W-36 36” 1/2” npt x 1/2” ips 261878 LYCSHAFC060060Y-36 36” 3/4” npt x 3/4” ips 261879 LYCSHAFC050010B-48 48” 1/2” npt x 1/2” cts 261880 LYCSHAFC050050W-48
LYCSHAFC060010B-48 LYCSHAFC060050W-48 LYCSHAFC060060Y-48 LYCSHAFC050010B-84
LYCSHAFC050050W-84 LYCSHAFC060010B-84 LYCSHAFC060050W-84 LYCSHAFC060060Y-84 LYCSHA-CFCY10-SEAL LYCSHA-CFCY14-SEAL
48” 1/2” npt x 1/2” ips 48” 3/4” npt x 1/2” cts 48” 3/4” npt x 1/2” ips 48” 3/4” npt x 3/4” ips 84” 1/2” npt x 1/2” cts 84” 1/2” npt x 1/2” ips 84” 3/4” npt x 1/2” cts 84” 3/4” npt x 1/2” ips 84” 3/4” npt x 3/4” ips 1/2” cts Service Head Gasket 1/2” ips Service Head Gasket
261881 261882 261883 261884 261885 261886 261887 261888 261889 269409 269408
victormfg.com
SECTION
7
Gas Pipe, Tubing & Fittings R.W. Lyall Propane Piping Systems (continued) Accessories for QRP Tool mfr# description Pipe Jaw Vise-Grip LYCAPJ070 LF-BOXQRP
webb#
1/2” CTS
3/4” CTS / 1/2” IPS
1” CTS / 3/4” IPS 11/4” CTS / 1” IPS Tool Box for QRP-100
183540 179097 179098 183518 179100
Time is money
To make sure you do each operation quickly, easily, and properly every time Lyall offers the right tools to assure the job is done correctly.
Accessories for LAP Tool mfr# description Pipe Clamp
LYCAPJ200PB-01 LYCLF-BOXLAP
webb#
Standard – 11/4” IPS Standard – 11/2” IPS Standard – 2” IPS Pull-Back – 2” IPS Tool Box for LAP-100
179105 193027 179107 179108 179109
7
Tools that make every job quick and easy. LYCOFIT® Tools allow for quick and easy installation of LYCOFIT® fittings. These tools provide perfect alignment and precision installment each and every time, without special training or time consuming measurements required. Quick Ratchet Press (QRP-100) The QRP-100 is a light weight, durable, single ratchet field assembly tool that installs all LYCOFIT® couplings from 1/2” CTS/IPS through 1” CTS. Dual Quick Ratchet Press (QRP-200) Designed for manual installations, the dual ratchet design of the QRP-200 makes it simple to install of medium to large sized piping systems. Installs all LYCOFIT® couplings from 3/4” IPS through 2” IPS. mfr# description LYCQRP-100 1/2” CTS — 1” IPS LYCQRP-200 3/4” CTS — 2” IPS
webb# 179095 252450
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
127
gas pipe, tubing & fittings
LYCOFIT® Installation Tools
SECTION
7
Gas Pipe, Tubing & Fittings
R.W. Lyall Propane Piping Systems (continued) Large Auto Press (LAP-100) This heavy duty hydraulic tool is designed to provide thousands of worry free installations quickly and easily. Installs 11/4”, 11/2” and 2” IPS LYCOFIT® couplings. mfr# description Hydraulic Tool & ENERPAC™ LYCLAP100 11/4” IPS — 2” IPS LYCAHP100 ENERPAC™ LYCHYDPRESS Kit
webb# 183440 183535 191819
LycoRing® Lightweight, disposable plastic ring that easily slips over the PE pipe and securely grips the pipe while inserting the pipe onto the LYCOFIT® spigot. The LycoRing® is included with the matching LYCOFIT® fitting and can be used with all LYCOFIT® configurations that use QRP and LAP tools, including tapping tee outlets. LycoRing® is provided with each LYCOFIT® fitting and eliminates the need for additional gripping tools to install fittings. Specifications • Meets or exceed all requirements for the Categorization of Mechanical Fittings within ASTM D2513-90c Category 1, and requirements from the Code of Federal Regulations, Title 49 Part 192.281 and 192.283. • Meets or exceeds NFPA-58 – 1002, DOT and ISO requirements. • Listed with IAPMO/UPS and CSA • Conforms to the Mechanical Fitting Specification as defined in ASTM F 1924. A complete set of specifications and test results for the product are available upon request.
128
Gas Equipment Catalog
victormfg.com
SECTION
7
Gas Pipe, Tubing & Fittings
7 gas pipe, tubing & fittings
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
129
SECTION
7
Gas Pipe, Tubing & Fittings
The internal seal enables each fitting to seal on scratched pipe. A seal is maintained on the smooth inside surface of the polyethylene pipe, regardless of the exterior surface of the piping. This improved seal protection creates the ultimate design for mechanical joints. Each Con-Stab fitting provides the following unique features: • Two internal seals • Fixed stiffener • Self-locking gripper • Moisture lip • Uni-body construction The Con-Stab I.D. Seal® fittings provide the user with the following advantages: • Cost effective joining method • Simple assembly • No additional assembly equipment required for installation (just chamfer pipe and push) • Expanded product line with various configurations and material options (PE 3408/4710 or PE 2406) • Uni-body design eliminating all external parts • Meets or exceeds all D.O.T., ASTM and NFPA 58 requirements Continental Industries is an ISO 9001 Certified Company. Continental’s Con-Stab I.D. Seal® product line is manufactured and tested to the following industry standards. • ASTM D 2513 “Standard Specification for Thermoplastic Gas Pressure Pipe, Tubing and Fittings” • ASME B31.8-1995 “Gas Transmission and Distribution Piping Systems” • D.O.T., Title 49 of the Code of Federal Regulations, Part 192.283 (b) • NFPA 58, LP-Gas Code
Chamfer Tools The CONSTAB CHAMFER tool is required for all CONSTAB fittings. Other Manufacturere’s tools will not produce a gas-tight connection. MFR#
SIZE WEBB#
Corrugated Stainless Steel 300 Series With Polyethylene Jacket CST0000-33-6580-04 1/2” CTS 371814 CST0000-33-6580-12 1/2” IPS 411913 CST0000-33-6580-13 3/4” IPS 371810 CST0000-33-6580-08 1” CTS 411526 CST0000-33-6580-14 1 IPS 371811 CST0000-33-6580-10 1-1/4 IPS 371813 CST0000-38-6580-16 1-1/2 IPS 269646 CST0000-33-6580-17 2 IPS 371809
130
Gas Equipment Catalog
victormfg.com
SECTION
7
Gas Pipe, Tubing & Fittings Service Head Risers Connection is made above-ground. No tool or fitting is required. MFR#
SIZE WEBB#
CST1253-92-1004-36 CST1253-92-1004-84 CST1253-92-1012-36 CST1252-92-1012-84 CST1353-92-1012-36 CST1353-92-1012-84 CST1353-92-1013-36 CST1353-92-1013-84
36” 1/2 NPT X 1/2 CTS 84” 1/2 NPT X 1/2 CTS 36” 1/2 NPT X 1/2 IPS 84” 1/2 NPT X 1/2 IPS 36” 3/4 NPT X 1/2 IPS 84” 3/4 NPT X 1/2 IPS 36” 3/4 NPT X 3/4 IPS 84” 3/4 NPT X 3/4 IPS
261875 261885 261876 261886 261878 261888 261879 261889
Risers without Couplings MFR#
SIZE WEBB#
CST1253-91-4604-00 CST1353-91-4604-00 CST1353-91-4612-00 CST1353-91-4613-00 CST1453-91-4614-00 CST1553-91-4615-0A CST1652-91-4616-00 CST1752-91-4617-00
1/2 NPT X 1/2 CTS 3/4 NPT X 1/2 CTS 3/4 NPT X1 /2 IPS 3/4 NPT X 3/4 IPS 1 NPT X 1 IPS 1-1/4 NPT X 1-1/4 IPS 1-1/2 NPT X 1-1/2 IPS 2 NPT X 2 IPS
193302 192989 180062 180063 183406 414143 193897 193898
7
Risers with Couplings SIZE WEBB#
CST1253-91-4604-25 CST1353-91-4604-25 CST1353-91-4612-25 CST1353-91-4613-25 CST1453-91-4614-25 CST9953-99-0503-25 CST1652-91-4616-25 CST1752-91-4617-25
1/2 NPT X 1/2 CTS 3/4 NPT X 1/2 CTS 3/4 NPT X 1/2 IPS 3/4 NPT X 3/4 IPS 1 NPT X 1 IPS 1-1/4 NPT X 1-1/4 IPS 1-1/2 NPT X 1-1/2 IPS 2 NPT X 2 IPS
gas pipe, tubing & fittings
MFR#
411528 411530 411533 411534 411542 411589 411547 411548
Couplings MFR#
SIZE WEBB#
CST3259-52-1004-00 CST3259-52-1012-00 CST3259-52-1013-00 CST3259-52-1008-00 CST3259-52-1014-00 CST3259-52-1015-AA CST3259-52-1016-00 CST3259-52-1017-00
1/2 CTS 1/2 IPS 3/4 IPS 1 CTS 1 IPS 1-1/4 IPS 1-1/2 IPS 2 IPS
269237 269238 269239 370557 269289 269240 269645 269241
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
131
SECTION
7
Gas Pipe, Tubing & Fittings Reducing Couplings MFR #
SIZE WEBB#
CST3259-54-1204-00 CST3259-54-1304-00 CST3259-54-1404-00 CST3259-54-1312-00 CST3259-54-1413-00 CST3259-54-1513-0A CST3259-54-1514-00 CST3259-54-1615-0A
1/2 IPS X 1/2 CTS 3/4 IPS X 1/2 CTS 1 IPS X 1/2 CTS 3/4 IPS X 1/2 IPS 1 IPS X 3/4 IPS 1-1/4 IPS X 3/4 IPS 1-1/4 IPS X 1 IPS 1-1/2 IPS X 1-1/4 IPS
269251 269252 269254 269253 269255 413038 269257 269644
Repair Couplings MFR#
SIZE WEBB#
CST3238-14-4415-AA CST3238-14-4417-00
1-1/4 IPS 2 IPS
371843 269267
Tees MFR#
SIZE WEBB#
CST3259-50-1004-00 CST3259-50-1012-00 CST3259-50-1013-00 CST3259-50-1008-00 CST3259-50-1014-00 CST3259-50-1015-AA CST3259-50-1016-00 CST3259-50-1017-00
1/2 CTS 1/2 IPS 3/4 IPS 1 CTS 1 IPS 1-1/4 IPS 1-1/2 IPS 2 IPS
269212 269213 269214 370558 269215 370556 269648 269217
Reducing Tees MFR#
SIZE WEBB#
CST3259-49-1304-00 CST3259-49-1404-00 CST3259-49-1413-00 CST3259-49-1715-0A
3/4 IPS X 1/2 CTS 1 IPS X 1/2 CTS 1 IPS X 3/4 IPS 2 IPS X 1-1/4 IPS
269259 269260 269261 269262
90째 Elbows
132
MFR#
SIZE WEBB#
CST3259-51-1004-00 CST3259-51-1012-00 CST3259-51-1013-00 CST3259-51-1008-00 CST3259-51-1014-00 CST3259-51-1015-AA CST3259-51-1016-00 CST3259-51-1017-00
1/2 CTS 1/2 IPS 3/4 IPS 1 CTS 1 IPS 1-1/4 IPS 1-1/2 IPS 2 IPS
Gas Equipment Catalog
269218 269219 269220 370559 269221 370554 269647 269223
victormfg.com
SECTION
7
Gas Pipe, Tubing & Fittings Cap-N-Go Fittings MFR#
SIZE WEBB#
CST3259-57-1004-00 CST3259-57-1013-00 CST3259-57-1015-0A CST3259-57-1017-00
1/2 CTS 3/4 IPS 1-1/4 IPS 2 IPS
269224 269225 269226 269227
Cap End MFR#
SIZE WEBB#
269242 269243 269244 370555 269246
CST3259-53-1004-00 CST3259-53-1013-00 CST3259-53-1014-00 CST3259-53-1015-0A CST3259-53-1017-00
1/2 CTS 3/4 IPS 1 IPS 1-1/4 IPS 2 IPS
Pex Copper Transition Couplings MFR#
SIZE WEBB#
CST9943-99-0064-00 CST9943-99-0065-00
1/2 PE X 1/2 OD COPPER 1/2 PE X 5/8 OD COPPER
269249 269250
Underground Gas Line Markers MFR#
DESCRIPTION WEBB#
MISUD21 VCTTRACERWIRE ELE1207PE30-YE
TAPE UNDERGROUND GAS 31-140 TRACER WIRE 500’ 14A Tracer Wire 500’ 12A
7 gas pipe, tubing & fittings
183516 359306 243218
Anode Bags - 17 lbs MFR#
DESCRIPTION WEBB#
CPRANODE17 ANODE MAGNESIUM BAGS 183403
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
133
SECTION
7
Connectors Stainless Steel Gas Connectors Residential Stainless Steel Gas Appliance Connectors
Dormont’s complete line of flexible, corrugated, Supr-Safe® stainless steel connectors attach all types of gas appliances to gas utility lines. . .easily and safely. We carry the largest inventory in the business, with connectors ranging from 3/8” through 11/2” O.D. MFR# od id lENGTH tHREAD tYPE WEBB# Water Heater, Gas Log, Space Heater, Connectors With Fittings 12” 3/8 mnpt end 242096 DOR10-2121-12 3/8” 1/4” 18” 3/8 mnpt end 202067 DOR10-2121-18 3/8” 1/4” 24” 3/8 mnpt end 185424 DOR10-2121-24 3/8” 1/4” 30” 3/8 mnpt end 246859 DOR10-2121-30 3/8” 1/4” 36” 3/8 mnpt end 244976 DOR10-2121-36 3/8” 1/4” 48” 3/8 mnpt end 246858 DOR10-2121-48 3/8” 1/4” 12” 3/8 fnpt end 185448 DOR10-2222-12 3/8” 1/4” 18” 3/8 fnpt end 188283 DOR10-2222-18 3/8” 1/4” 24” 3/8 fnpt end 215474 DOR10-2222-24 3/8” 1/4” 36” 3/8 fnpt end 213164 DOR10-2222-36 3/8” 1/4” 48” 3/8 fnpt end 245962 DOR10-2222-48 3/8” 1/4” 18” 1/2 mnpt end 209723 DOR10-3131-18 3/8” 1/4” 36” 1/2 mnpt end 209724 DOR10-3131-36 3/8” 1/4” Dryer Connections With Fittings 18” 3/8 mnpt/fnpt 163856 DOR20-2122-18 1/2” 3/8” 30” 3/8 mnpt/fnpt 163857 DOR20-2122-30 1/2” 3/8” 36” 3/8 fnpt 192747 DOR20-2222-36 1/2” 3/8” 48” 3/8 fnpt 206103 DOR20-2222-48 1/2” 3/8” 12” 1/2 mnpt–3/8 fnpt 191054 DOR20-3122-12 1/2” 3/8” 18” 1/2 mnpt–3/8 fnpt 192608 DOR20-3122-18 1/2” 3/8” 24” 1/2 mnpt–3/8 fnpt 191055 DOR20-3122-24 1/2” 3/8” 36” 1/2 mnpt–3/8 fnpt 192613 DOR20-3122-36 1/2” 3/8” 48” 1/2 mnpt–3/8 fnpt 192610 DOR20-3122-48 1/2” 3/8” 60” 1/2 mnpt–3/8 fnpt 192611 DOR20-3122-60 1/2” 3/8” 72” 1/2 mnpt–3/8 fnpt 191056 DOR20-3122-72 1/2” 3/8” 12” 1/2 mnpt 166786 DOR20-3131-12 1/2” 3/8” 18” 1/2 mnpt 209421 DOR20-3131-18 1/2” 3/8” 24” 1/2 mnpt 166228 DOR20-3131-24 1/2” 3/8” 36” 1/2 mnpt 209422 DOR20-3131-36 1/2” 3/8” 48” 1/2 mnpt 166229 DOR20-3131-48 1/2” 3/8” 60” 1/2 mnpt 209423 DOR20-3131-60 1/2” 3/8” 36” 1/2 mnpt–1/2 fnpt 215815 DOR20-3132-36 1/2” 3/8” 48” 1/2 mnpt–1/2 fnpt 224158 DOR20-3132-48 1/2” 3/8” Range Connectors With Fittings 12” 1/2 mnpt 245963 DOR30-3131-12 5/8” 1/2” 18” 1/2 mnpt 218889 DOR30-3131-18 5/8” 1/2” 24” 1/2 mnpt 193511 DOR30-3131-24 5/8” 1/2” 30” 1/2 mnpt 201236 DOR30-3131-30 5/8” 1/2” 36” 1/2 mnpt 79589 DOR30-3131-36 5/8” 1/2” 48” 1/2 mnpt 179822 DOR30-3131-48 5/8” 1/2” 60” 1/2 mnpt 212867 DOR30-3131-60 5/8” 1/2” 72” 1/2 mnpt 218890 DOR30-3131-72 5/8” 1/2” 24” 1/2 mnpt–1/2 fnpt 204534 DOR30-3132-24 5/8” 1/2” 30” 1/2 mnpt–1/2 fnpt 163854 DOR30-3132-30 5/8” 1/2” 48” 1/2 mnpt–1/2 fnpt 163855 DOR30-3132-48 5/8” 1/2” 12” 1/2 fnpt 185449 DOR30-3232-12 5/8” 1/2” 18” 1/2 fnpt 68547 DOR30-3232-18 5/8” 1/2” 24” 1/2 fnpt 68548 DOR30-3232-24 5/8” 1/2” 36” 1/2 fnpt 68549 DOR30-3232-36 5/8” 1/2” 48” 1/2 fnpt 68692 DOR30-3232-48 5/8” 1/2” 60” 1/2 fnpt 185458 DOR30-3232-60 5/8” 1/2” 72” 1/2 fnpt 185460 DOR30-3232-72 5/8” 1/2”
134
Gas Equipment Catalog
victormfg.com
SECTION
7
Connectors Stainless Steel Gas Connectors (continued) Low Visibility Hearth Connectors Black mfr#
OD ID Length Thread type webb#
DOR10A-2121-12 DOR10A-212-18 DOR10A-2121-24 DOR10A-3131-12 DOR10A-3131-18 DOR10A3131-24 DOR10A-3131-30
3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
MFR# od
1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4”
12” 18” 24” 12” 18” 24” 30”
3/8 mnpt end 3/8 mnpt end 3/8 mnpt end 1/2 mnpt end 1/2 mnpt end 1/2 mnpt end 1/2 mnpt end
308566 308567 308568 308576 308577 308578 308579
id lENGTH tHREAD tYPE WEBB#
Range Connectors With End Fittings 18” DOR30-4141-18 5/8” 1/2” 24” DOR30-4141-24 5/8” 1/2” 36” DOR30-4141-36 5/8” 1/2” 18” DOR30-4144-18 5/8” 1/2” 24” DOR30-4144-24 5/8” 1/2” 36” DOR30-4144-36 5/8” 1/2” 48” DOR30-4144-48 5/8” 1/2” 18” DOR30-4242-18 5/8” 1/2” 24” DOR30-4242-24 5/8” 1/2” 36” DOR30-4242-36 5/8” 1/2” 48” DOR30-4242-48 5/8” 1/2” 60” DOR30-4242-60 5/8” 1/2” 72” DOR30-4242-72 5/8” 1/2” 3/4” 24” DOR40-4142-24 1”
3/4 mnpt 3/4 mnpt 3/4 mnpt
3/4 mnpt–3/4” mnpt 90 3/4 mnpt–3/4” mnpt 90 3/4 mnpt–3/4” mnpt 90 3/4 mnpt–3/4” mnpt 90 3/4 fnpt 3/4 fnpt 3/4 fnpt 3/4 fnpt 3/4 fnpt 3/4 fnpt
3/4 mnpt–3/4 fnpt
213943 213944 197947 67650 55306 67651 67653 55305 67652 55307 55308 185457 185459 184568
End Fittings mfr#
Description
246634 179505 185463 209028 185462 185461
Connector Flow Capacity (Per ANSI Z21.24)
Series
Nominal connector ID, INCH
10
1/4”
20
3/8”
30
1/2”
Straight LEngth Capacity – BTU PEr Hr (w) 0.64 Sp. Gr. 1000 BTU Per Cu Ft. (37.2 MJ/m3) Gas at 0.5 Inch Water Column (124 Pa) Pressure Drop 1 foot (0.30 m) 48000 (14 067) 102000 (29 893) 180000 (52 811)
11/2 Foot (0.48 m) 43800 (12 837) 93100 (27 285) 164200 (48 122)
2 foot (0.61 m) 400000 (11 723) 85000 (24 911) 150000 (43 961)
21/2 Foot (0.76 m) 36400 (10 668) 77100 (22 742) 136000 (40 034)
3 Foot (0.91 m) 33400 (9 789) 71100 (20 837) 125000 (36 634)
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
4 foot (1.22 M) 28300 (8 294) 60500 (17 731) 106000 (31 066)
5 foot (1.52 M) 24900 (7 297) 53200 (15 591) 93200 (27 314)
6 Foot (1.83 m) 23100 (6 770) 49100 (14 390) 86000 (25 380)
135
gas pipe, tubing & fittings
Dryer 20 Series (Fittings for 1/2” OD Connectors) 1/2” fnpt For 1/2” OD (3/8” ID) DOR90-2032 3/4” fnpt For 1/2” OD (3/8” ID) DOR90-2042 Dryer 30 Series (Fittings for 5/8” OD Connectors) 1/2” mnpt For 5/8” OD (1/2” ID) DOR90-3031 3/4” mnpt For 5/8” OD (1/2” ID) DOR90-3041 DOR90-3032 1/2” fnpt For 5/8” OD (1/2” ID) 3/4” fnpt For 5/8” OD (1/2” ID) DOR90-3042
7
webb#
SECTION
7
Connectors Stainless Steel Gas Connectors (continued)
Commercial Supr-Safe® Disconnect Gas Appliance Connectors – BPQ Series Stainless Steel corrugated hose, encased in a stainless steel braid, covered with a thick SuperFlex coating and fitted with an A Type “Push-to-Connect” quick disconnect coupling.
Dormont Moveable Connector with Push-to-Connect Quick Disconnect.
mfr# description webb# 1/2” Quick Couplings 1/2” X 36” 213236 DOR1650BPQ36 1/2” X 48” 185437 DOR1650BPQ48 1/2” X 60” 185439 DOR1650BPQ60 3/4” Quick Couplings 3/4” X 36” 185435 DOR1675BPQ36 3/4” X 48” 185436 DOR1675BPQ48 3/4” X 60” 185438 DOR1675BPQ60 1” Quick Couplings DOR16100BPQ24 1” X 24” 216370 DOR16100BPQ36 1” X 36” 216371 DOR16100BPQ48 1” X 48” 204050 3/4” Quick Coupling with Restraining Device* 3/4” X 36” 163870 DOR1675BPQR36 Restraining Device Coils DORRDC-36 For 36” Commercial Flex DORRDC-48 For 48” Commercial Flex
163862 163863
SnapFast™ Connectors DORA50 1/2” Snap Fast Connector 163860 DORA75 3/4” Snap Fast Connector 163861 * Also available as kit with restraining device, special order.
BTU Flow Capacities Gas Connectors for Moveable Equipment length MFR# 1650b, 1650bp 1650bq, bpq, bpqb, bpcf 1675b, 1675bp 1675bq, bpq, bpqb, bpcf 16100b, 16100bp 16100bq, bpq, bpqb, bpcf 16125b, 16125bp 16125bq, bpq
inside dia. 1/2” 1/2” 3/4” 3/4” 1” 1” 11/4” 11/4”
12” 15,2000 98,000 326,000 260,000 652,000 425,000 1,204,000 783,000
24” 150,000 870,00 291,000 232,000 582,000 414,000 1,075,000 699,000
36” 120,000 77,000 256,000 218,000 512,000 379,000 946,000 615,000
48” 106,000 68,000 225,000 180,000 451,000 334,000 833,000 541,000
60” 93,000 60,000 198,000 158,000 397,000 294,000 733,000 476,000
72” 87,000 55,000 175,000 139,000 350,000 279,000 645,000 419,000
Gas Connectors for Moveable Equipment With Safety Quik and Supr-Swivel Fittings length MFR# 1650bpqs, bpcfs 1650bpq2s, bpcf2s 1675bpqs, bpcfs 1675bpq2s, bpcf2s 16100bpqs, bpcfs 16100bpq2s, bpcf2s
inside dia. 1/2” 1/2” 3/4” 3/4” 1” 1”
12” 92,000 88,000 242,000 230,000 396,000 377,000
24” 81,000 77,000 216,000 205,000 385,000 366,000
36” 72,000 69,000 203,000 193,000 353,000 336,000
48” 63,000 60,000 167,000 160,000 310,000 295,000
60” 56,000 54,000 147,000 140,000 274,000 261,000
72” 51,000 48,000 130,000 124,000 260,000 247,000
CSA International design certifies gas connectors for a maximum operating pressure of 0.5 psig. Capacities shown, which exceed minimum ANSI requirements, are results from independent testing laboratories. Minimum required BTU capacities for gas connectors (B & BP models) are defined by ANSI Z21.69. Flow capacities for connector assemblies exclude manual shut-off valves. BTU capacities decrease when the length of the connector increase. Flow rating BTU 0.64 SP.GR at 0.5 W.C. pressure drop.
136
Gas Equipment Catalog
victormfg.com
SECTION
7
Fittings
Brass Flare Fittings #42 Flare X Flare Union MfR# Code
Size
U2-2 U2-3 U2-4 U2-5 U2-6 U2-8 U2-10 U2-12 U2-14
1/8
SAE18UN SAE316UN SAE14UN SAE516UN SAE38UN SAE12UN SAE58UN SAEU2-12 SAE78UN
webb# 19795 19796 19797 19798 19799 19801 19802 19803 19804
3/16 1/4 5/16 3/8 1/2 5/8 3/4 7/8
#42R Flare X Flare Reducing Union MfR# Code
Size
UR2-64 UR2-86 UR2-108 UR2-84 UR2-106 UR2-128
3/8 X 1/4
SAE38X14UN SAE12X38UN SAE58X12UN SAE12X14UN SAE58X38UN SAE34X12UN
webb#
1/2 X 3/8 5/8 X 1/2 1/2 X 1/4 5/8 X 3/8 3/4 X 1/2
30291 34574 34820 34818 34819 19792
#46 Flare X Female (FPT) Union Size webb#
U3-3A U3-4A U3-4B U3-6A U3-6B U3-6C U3-6D U3-6E U3-8B U3-8C U3-8D U3-8E U3-10C U3-10D U3-10E U3-12E
3/16 X 1/8
SAE316ODX18FA SAE14ODX18FA SAE14ODXFA SAE38ODX18FA SAE38ODX14FA SAE38ODXFA SAE38ODX12FA SAE38ODX34FA SAE12ODX14FA SAE12ODX38FA SAE12ODXFA SAE12ODX34FA SAE58ODX38FA SAE58ODX12FA SAE58ODX34FA SAE34ODX34FA
1/4 X 1/8 1/4 X 1/4 3/8 X 1/8 3/8 X 1/4 3/8 X 3/8 3/8 X 1/2 3/8 X 3/4 1/2 X 1/4 1/2 X 3/8 1/2 X 1/2 1/2 X 3/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4 3/4 X 3/4
19747 19748 19749 19754 19755 19756 19757 19758 19759 19760 19761 19762 19763 19764 19765 19767
#114 Swivel Nut Female Flare X Female Flare MfR# Code
Size webb#
1/4 US4-4 SAE14SWIVELNUT US4-6 SAE38SWIVELNUT 3/8 US4-8 SAE12SWIVELNUT 1/2 US4-10 SAE58SWIVELNUT 5/8 US4-86 SAE12X38SWIVELNUT 1/2 X 3/8 US4-108 SAE58X12SWIVELNUT 5/8 X 1/2
78995 77598 77599 78996 95739 95738
MfR# Code
Size
U1-2A U1-3A U1-4A U1-4B U1-4C U1-4D U1-5A U1-5B U1-5C U1-6A U1-6B U1-6C U1-6D U1-6E U1-8B U1-8C U1-8D U1-8E U1-10B U1-10C U1-10D U1-10E U1-12D U1-12E U1-14E LONG
1/8 X 1/8 3/16 X 1/8 3/16 X 1/4 1/4 X 1/8 1/4 X 1/4 1/4 X 3/8 1/4 X 1/2 5/16 X 1/8 5/16 X 1/4 5/16 X 3/8 3/8 X 1/8 3/8 X 1/4 3/8 X 3/8 3/8 X 1/2 3/8 X 3/4 1/2 X 1/4 1/2 X 3/8 1/2 X 1/2 1/2 X 3/4 5/8 X 1/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4 3/4 X 1/2 3/4 X 3/4 7/8 X 3/4 3/8 X 3/8 3/8 X 1/2 1/2 X 1/2 5/8 X 1/2
SAE18MUN SAE316X18MUN SAE316X14MUN SAE14X18MUN SAE14MUN SAE14X38MUN SAE14X12MUN SAE516X18MUN SAE516X14MUN SAE516X38MUN SAE38X18MUN SAE38X14MUN SAE38X38MUN SAE38X12MUN SAE38X34MUN SAE12X14MUN SAE12X38MUN SAE12X12MUN SAE12X34MUN SAE58X14MUN SAE58X38MUN SAE58X12MUN SAE58X34MUN SAE34X12MUN SAE34ODX34MUN SAE78X34MUN SAE38X38MUNLNG SAE38X12MUNLNG SAE12X12MUNLNG SAE58X12MUNLNG
webb# 19769 19770 19771 19772 19773 19774 19775 19776 19777 19778 19779 19780 19781 19782 19783 19784 19785 19786 19787 19788 19789 19790 19791 368566 19793 19794 361612 361613 361614 361615
7
#446 Flare Cap Female Flare MfR# Code
Size
N5-3 N5-4 N5-5 N5-6 N5-8 N5-10
3/16 1/4 5/16 3/8 1/2 5/8
SAE316CAP SAE14CA SAE516CAP SAE38CA SAE12CA SAE58CAP
gas pipe, tubing & fittings
MfR# Code
#48 Flare X Male (MPT) Union
webb# 19735 19736 19737 19738 19739 19740
#447 Flare Plug Male Flare MfR# Code
Size Webb#
P2-4 P2-6 P2-8 P2-10
1/4 3/8 1/2 5/8
SAE14PL SAE38PL SAE12PL SAE58PL
19742 19744 19745 19746
#461 Flare Bonnets MfR# Code
Size
B1-4 B1-6 B1-8 B1-10
1/4 3/8 1/2 5/8
SAE461-4 SAE38BONNET SAE12BONNET SAE461-10
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
webb# 185393 185395 185396 185391
137
SECTION
7
Fittings Brass Flare Fittings #44 Flare X Flare X Flare Tee MfR# Code
Size
T2-2 T2-3 T2-4 T2-5 T2-6 T2-8 T2-10 T2-12
1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4
SAE18T SAE316T SAE14T SAE516T SAE38T SAE12T SAE58T SAE34T
webb# 19856 19857 19858 19859 19860 19861 19862 19863
#44R Flare X Flare X Flare Reducing Tee MfR# Code TR2-664 TR3-668 TR2-886 TR2-10106 TR2-10808 TR2-10810 TR2-868 TR2-8810
Size WEbb#
3/8 X 1/4 34826 SAE38X14T SAE38X12T 3/8 X 1/2 34827 SAE12X38T 1/2 X 3/8 34833 SAE58X38T 5/8 X 3/8 34838 SAE58X12T 5/8 X 1/2 34839 SAE58X12X58T 5/8 X 1/2 X 5/8 191825 SAE12X38X12T 1/2 X 3/8 X 1/2 192879 SAE12X58T 1/2 X 5/8 192880
#45 Flare X Flare X Male (MPT) Tee MfR# Code
Size webb#
T1-6C T1-8D T1-6B T1-10D
3/8 X 3/8 1/2 X 1/2 3/8 X 1/4 5/8 X 1/2
SAE38ODX38MT2 SAE12ODX12MT2 SAE38ODX14MT5 SAE58ODX12MT5
19872 19875 19883 19888
#481 Forged Flare Nut MfR# Code
Size Webb#
NS4-4 NS4-6 NS4-8 NS4-10 NSR4-86 NSR4-108
1/4 34570 3/8 34571 1/2 34572 5/8 34814 1/2 X 3/8 215886 5/8 X 1/2 215887
138
SAE14RNUT SAE38RNUT SAE12RNUT SAE58RNUT SAE12X38RNUT SAE58X12RNUT
Gas Equipment Catalog
#55 Flare X Flare Elbow MfR# Code
Size
E2-2 E2-3 E2-4 E2-5 E2-6 E2-8 E2-10 E2-12 ER2-64 ER2-86 ER2-106 ER2-108
1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4 3/8 X 1/4 1/2 X 3/8 5/8 X 3/8 5/8 X 1/2
SAE1890 SAE31690 SAE1490 SAE51690 SAE3890 SAE1290 SAE5890 SAE3490 SAE38X1490 SAE12X3890 SAE58X3890 SAE58X1290
webb# 19847 19848 19849 19850 19851 19852 19853 19854 34823 34824 94502 94503
#49 Flare X Male (MPT) Elbow MfR# Code
Size
E1-2A E1-3A E1-3B E1-4A E1-4B E1-4C E1-4D E1-5A E1-5B E1-5C E1-6A E1-6B E1-6C E1-6D E1-6E E1-8B E1-8C E1-8D E1-8E E1-10C E1-10D E1-10E E1-12D
1/8 3/16 X 1/8 3/16 X 1/4 1/4 X 1/8 1/4 1/4 X 3/8 1/4 X 1/2 5/16 X 1/8 5/16 X 1/4 5/16 X 3/8 3/8 X 1/8 3/8 X 1/4 3/8 X 3/8 3/8 X 1/2 3/8 X 3/4 1/2 X 1/4 1/2 X 3/8 1/2 X 1/2 1/2 X 3/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4 3/4 X 1/2
SAE18M90 SAE316X18M90 SAE316X14M90 SAE14X18M90 SAE14M90 SAE14X38M90 SAE14ODX12M90 SAE516X18M90 SAE516X14M90 SAE516X38M90 SAE38X18M90 SAE38X14M90 SAE38X38M90 SAE38X12M90 SAE38ODX34M90 SAE12X14M90 SAE12X38M90 SAE12X12M90 SAE12ODX34M90 SAE58X38M90 SAE58ODX12M90 SAE58ODX34M90 SAE34ODX12M90
webb# 19823 19824 19825 19826 19827 19828 19829 19830 19831 19832 19833 19834 19835 19836 19837 19838 19839 19840 19841 19843 19844 19845 19846
#564 Flare X Female (FPT) Elbow MfR# Code
Size Webb#
E3-6C E3-6D E3-8D E3-8E E3-10C E3-10D E3-10E
3/8 X 3/8 3/8 X 1/2 1/2 X 1/2 1/2 X 3/4 5/8 X 3/8 5/8 X 1/2 5/8 X 3/4
SAE38ODX38F90 SAE38ODX12F90 SAE12ODX12F90 SAE12ODX34F90 SAE58ODX38F90 SAE58ODX12F90 SAE58ODX34F90
19813 19814 19818 19819 19820 19821 19822
victormfg.com
SECTION
7
Fittings
Propane Hose & Fittings Hose Barb to Male Pipe Fitting MFR# SAE14Hx18M SAE14Hx14M SAE14Hx38M SAE38Hx18M SAE38Hx14M SAE38Hx38M SAE38Hx12M
Description Webb# 1/4” I.D. Hose X 1/8” MPT 19964 1/4” I.D. Hose X 1/4” MPT 19965 1/4” I.D. Hose X 3/8” MPT 19966 3/8” I.D. Hose X 1/8” MPT 19969 3/8” I.D. Hose X 1/4” MPT 19970 3/8” I.D. Hose X 3/8” MPT 19971 3/8” I.D. Hose X 1/2” MPT 19972
Hose Barb to Female Flare Swivel MFR# SAE14Hx38FFL SAE38Hx38FFL SAE38Hx12FFL
Description Webb# 1/4” I.D. Hose X 3/8” Female Flare Swivel 110988 3/8” I.D. Hose X 3/8” Female Flare Swivel 184985 3/8” I.D. Hose X 1/2” Female Flare Swivel 223454
Hose Barb to Male Flare MFR# SAE14Hx38MFL SAE38Hx38MFL SAE38Hx12MFL
Description Webb# 1/4” I.D. Hose X 3/8” Male Flare 193397 3/8” I.D. Hose X 3/8” Male Flare 182631 3/8” I.D. Hose X 1/2” Male Flare
Hose Barb to Female Pipe Fitting Description Webb# 1/4” I.D. Hose X 1/8” FPT 184998 1/4” I.D. Hose X 1/4” FPT 19941 1/4” I.D. Hose X 3/8” FPT 19942 3/8” I.D. Hose X 1/8” FPT 185000 3/8” I.D. Hose X 1/4” FPT 19946 3/8” I.D. Hose X 3/8” FPT 19947 3/8” I.D. Hose X 1/2” FPT 19948
Hose Barb to 9/16”—18 LH Female Swivel
MFR# SAE622-201
Description Webb# 3/8” Hose Nip X 9/16”–18 LH Female Swivel 193398
Hose Barb X Soft Nose Hand Wheel POL
MFR# Description Webb# SAE14HxMPOLHW 1/4” I.D. Hose X Soft Nose Hand Wheel POL 182646
Hose Barb X POL MFR# Description Webb# 182655 SAE14HxMPOL 1/4” I.D. Hose X POL (7/8” Hex)
MFR# Description Webb# 182653 SAE14MX14MINV 1/4” I.D. Hose X 1/4” Inverted Flare Male
Gates LP Grill Hose MFR# HOS14-2 HOS3/8 HOS1/2 HOS3/4 HOS1ID
Description Webb# 1/4” Double Braid Hose 185588 3/8” Double Braid Hose 185605 1/2” Double Braid Hose 185581 3/4” Double Braid Hose 185604 1” Double Braid Hose 185591
Brass Hose Ferrule MFR# HOF7326 HOF7327 HOF7328 HOF7329 HOF7331 HOF7332 HOF7333 SPFKT-15
Size .593” .625” .656” .687” .750” — .812” —
Description Webb# Brass Hose Ferrule For 1/4” Hose 185561 Brass Hose Ferrule For 1/4” Hose 185562 Brass Hose Ferrule For 1/4” Hose 185563* Brass Hose Ferrule For 3/8” Hose 185564 Brass Hose Ferrule For 3/8” Hose 185565 Brass Hose Female for 3/8” Hose 252788* Brass Hose Ferrule For 3/8” Hose 185566 3-Hole Crimping Tool For Brass Ferrule 184210
* Use with current stock thermoid hose.
Ear Clamps & Jaw Pinchers MFR# Description Webb# OET10100011 Oetiker 2 Ear Clamp 3/8” 183382 OET14100082 Standard Jaw Pinchers 185559 OET10100016 Oetiker 2 Ear Clamp 1/2” 183383 OET10100019 Oetiker 2 Ear Clamp 9/16” (1/4” Single Braid Hose) 183384 OET10100022 Oetiker 2 Ear Clamp 19/32” (1/4” Double Braid Hose) 183385 OET10100024 Oetiker 2 Ear Clamp 5/8” (1/4” Double Braid Hose) 183386 OET10100027 Oetiker 2 Ear Clamp 3/4” (3/8” Double Braid Hose) 183388 OET10100032 Oetiker 2 Ear Clamp 15/16” 183387
Premade Hose with Male Ends MFR# SIZE (INCHES) LENGTH(FEET) VCT50A1900030 3/8 6 VCT50A1900100 3/8 12 VCT50A1900101 3/8 18 HFBLP350X12X6FT 1/2 6 HFBLP350X12X10FT 1/2 10 HFBLP350X12X15FT 1/2 15 HFBLP350X12X18FT 1/2 18 HFBLP350X12X20FT 1/2 20 HFBLP350X12X25FT 1/2 25 HFBLP350X12X50FT 1/2 50 HFBLP350X12X100FT 1/2 100
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
WEBB# 370042 370041 370040 438644 438645 438646 438647 438648 438649 438650 438651
139
7 gas pipe, tubing & fittings
MFR# SAE14Hx18F SAE14Hx14F SAE14Hx38F SAE38Hx18F SAE38Hx14F SAE38Hx38F SAE38Hx12F
Hose Barb X Inverted Flare
SECTION
7
Fittings Black Malleable Fittings
45° Elbow MFR#
SIZE WEBB#
MAL1845
1/8”
12559
MAL1445
1/4”
12560
MAL3845
3/8”
12561
MAL1245
1/2”
12562
MAL3445
3/4”
12563
MAL145
1”
12564
MAL11445
11/4”
12565
MAL11245
11/2”
12566
MAL245
2”
12567
MAL21245
21/2”
12568
MAL345
3”
12569
MFR#
90° Street Elbow MFR#
SIZE WEBB#
MAL18S90
1/8”
12547
MAL14S90
1/4”
12548
MAL38S90
3/8”
12549
MAL12S90
1/2”
12550
MAL34S90
3/4”
12551
MAL1S90
1”
12552
MAL114S90 11/4”
12553
MAL112S90 11/2”
12554
MAL2S90
12555
2”
MAL212S90 21/2”
45° Street Elbow
90° Reducing Elbow
12556
SIZE WEBB#
MAL14X1890 1/4” X 1/8”
12518
MAL38X1490 3/8” X 1/4”
12519
MAL12X3890 1/2” X 3/8”
12521
MAL12X1490 1/2” X 1/4”
12522
MAL34X1290 3/4” X 1/2”
12523
MAL34X3890 3/4” X 3/8”
12524
MAL34X1490 3/4” X 1/4”
12525
MAL1X3490
1” X 3/4”
12526
MAL1X1290
1” X 1/2”
12527
MAL114X190 11/4” X 1”
MAL114X1290 11/4” X 1/2” 12531 MAL112X11490 11/2” X 11/4” 12532 MAL112X190 11/2” X 1”
Cross
12529
MAL114X3490 11/4” X 3/4” 12530
12533
SIZE WEBB#
MFR#
SIZE WEBB#
MAL2X11290 2” X 11/2”
12535
MAL18S45
1/8”
12574
MAL14CR
1/4”
12760
MAL2X11490 2” X 11/4”
12536
MAL14S45
1/4”
12575
MAL38CR
3/8”
12761
MAL2X190
2” X 1”
12537
MAL38S45
3/8”
12576
MAL12CR
1/2”
12762
MAL2X3490
2” X 3/4”
12538
MAL12S45
1/2”
12577
MAL34CR
3/4”
12763
MAL212X290 21/2” X 2”
MAL34S45
3/4”
12578
MAL1CR
1”
12764
MAL212X11290 21/2” X 11/2” 12540
MAL1S45
1”
12579
MAL114CR
11/4”
12765
MAL3X21290 3” X 21/2”
MAL114S45 11/4”
12580
MAL112CR
11/2”
12766
MAL3X290
MAL112S45 11/2”
12581
MAL2CR
2”
12767
MAL2S45
12582
MFR#
SIZE WEBB#
MAL1890
1/8”
12503
MAL1490
1/4”
12504
MAL3890
3/8”
12505
MAL1290
1/2”
12506
MAL3490
3/4”
12507
MAL190
1”
12508
MAL11490
11/4”
12509
MAL11290
11/2”
12510
MAL290
2”
12511
MAL21290
21/2”
12512
MAL390
3”
12513
140
3” X 2”
12539 12541 12542
Plug
Coupling
90° Elbow
MFR#
SIZE WEBB#
MAL18CA
1/8”
12851
MAL14CA
1/4”
12852
MAL38CA
3/8”
12853
MAL12CA
1/2”
12854
MAL34CA
3/4”
12855
MAL1CA
1”
12856
MAL114CA
11/4”
12857
MAL112CA
11/2”
12858
MAL2CA
2”
12859
MAL212CA
21/2”
12860
MAL3CA
3”
12861
MAL112X3490 11/2” X 3/4” 12534
MFR#
2”
Cap
MFR#
SIZE WEBB#
MFR#
SIZE WEBB#
MAL18CO
1/8”
12774
Solid BCI18SOPL
1/8”
1380
MAL14CO
1/4”
12775
BCI14SOPL
1/4”
1381
MAL38CO
3/8”
12776
BCI38SOPL
3/8”
1382
1/2”
1383 1371
MAL12CO
1/2”
12777
BCI12SOPL
MAL34CO
3/4”
12778
BCI34SOPL
3/4”
MAL1CO
1”
12779
BCI1SOPL
1”
197665
MAL114CO
11/4”
12780
BCI2SOPL
2”
1388
MAL112CO
11/2”
12781
MAL2CO
2”
12782
Cored BCI12PL
1/2”
206693
MAL3CO
3”
12784
BCI34PL
3/4”
203284
BCI1PL
1”
1385
BCI114PL
11/4”
1373
BCI112PL
11/2”
1387
BCI2PL
2”
1375
BCI212PL
21/2”
BCI3PL
3”
Gas Equipment Catalog
Union MFR#
SIZE WEBB#
MAL18UN
1/8”
54291
MAL14UN
1/4”
30254
MAL38UN
3/8”
30255
MAL12UN
1/2”
30256
MAL34UN
3/4”
30257
MAL1UN
1”
30258
MAL114UN
11/4”
30259
MAL112UN
11/2”
30260
MAL2UN
2”
30261
MAL3UN
3”
30263
Tee MFR#
SIZE WEBB# 1/8”
1376
MAL18T MAL14T MAL38T MAL12T MAL34T MAL1T MAL114T MAL112T MAL2T MAL212T
1377
MAL3T
1/4” 3/8” 1/2” 3/4”
1” 11/4” 11/2” 2” 21/2” 3”
12586 12587 12588 12589 12590 12591 12592 12593 12594 12595 12596
victormfg.com
SECTION
7
Fittings
Black Malleable Fittings (continued) Reducing Tee SIZE WEBB# 12601 1/4” X 1/4” X 1/8” 12603 3/8” X 3/8” X 1/4” 12605 3/8” X 1/4” X 1/4” 12608 1/2” X 1/2” X 1” 12609 1/2” X 1/2” X 3/4” 12610 1/2” X 1/2” X 3/8” 12611 1/2” X 3/8” X 1/2” 12613 1/2” X 3/8” X 3/8” 12614 1/2” X 1/4” X 1/2” 12615 3/4” X 1/2” X 1/2” 12622 3/4” X 1/2” X 3/4” 12621 3/4” X 1/4” X 3/4” 12625 3/4” X 3/4” X 11/4” 12616 3/4” X 3/4” X 1/2” 12618 3/4” X 3/4” X 1/4” 12620 3/4” X 3/4” X 1” 12617 3/4” X 3/4” X 3/8” 12619 30252 1” X 1” X 1/2” 12627 1” X 1” X 11/2” 12628 1” X 1” X 11/4” 12631 1” X 1” X 3/8” 12632 1” X 1” X 1/4” 12633 1” X 3/4” X 1” 12634 1” X 3/4” X 3/4” 12635 1” X 3/4” X 1/2” 12636 1” X 1/2” X 1” 12637 1” X 1/2” X 3/4” 12638 1” X 1/2” X 1/2” 12639 1” X 1/4” X 1” 11/4” X 11/4” X 2” 12640 11/4” X 11/4” X 11/2” 12641 11/4” X 11/4” X 1” 12642 11/4” X 11/4” X 3/4” 12643 11/4” X 11/4” X 1/2” 12644 11/4” X 1” X 11/4” 12647 12648 11/4” X 1” X 1” 12649 11/4” X 1” X 3/4” 12650 11/4” X 1” X 1/2” 11/4” X 3/4” X 11/4” 12651 12652 11/4” X 3/4” X 1” 11/4” X 3/4” X 3/4” 12653 11/4” X 1/2” X 11/4” 12655 12656 11/4” X 1/2” X 1” 11/2” X 11/2” X 2” 12661 11/2” X 11/2” X 11/4” 12662 11/2” X 11/2” X 1” 12663 11/2” X 11/2” X 3/4” 12664 11/2” X 11/2” X 1/2” 12665 1/8” X 1/8” X 1/4”
MFR# MAL112X114X112T MAL112X114X114T MAL112X114X1T MAL112X114X34T MAL112X114X12T MAL112X1X112T MAL112X1X114T MAL112X1X1T MAL112X1X34T MAL112X34X112T MAL112X34X34T MAL112X12X112T MAL2X2X212T MAL2X2X112T MAL2X2X114T MAL2X2X1T MAL2X2X34T MAL2X2X12T MAL2X112X2T MAL2X112X112T MAL2X112X114T MAL2X112X1T MAL2X112X34T MAL2X114X2T MAL2X114X114T MAL2X1X2T MAL2X1X1T MAL2X34X2T MAL2X12X2T MAL212X212X2T MAL212X212X112T MAL212X212X114T MAL212X212X1T MAL212X212X34T MAL212X2X212T MAL212X2X2T MAL212X112X2T MAL3X3X212T MAL3X3X2T MAL3X3X112T MAL3X3X114T MAL3X3X1T MAL3X3X34T MAL3X212X2T MAL3X2X3T MAL3X2X2T
SIZE WEBB# 11/2” X 11/4” X 11/2” 12667 11/2” X 11/4” X 11/4” 12668 11/2” X 11/4” X 1” 12669 11/2” X 11/4” X 3/4” 12670 11/2” X 11/4” X 1/2” 12671 11/2” X 1” X 11/2” 12672 11/2” X 1” X 11/4” 12673 12674 11/2” X 1” X 1” 12675 11/2” X 1” X 3/4” 11/2” X 3/4” X 11/2” 12677 11/2” X 3/4” X 3/4” 12680 11/2” X 1/2” X 11/2” 12681 12684 2” X 2” X 21/2” 12685 2” X 2” X 11/2” 12686 2” X 2” X 11/4” 12687 2” X 2” X 1” 12688 2” X 2” X 3/4” 12689 2” X 2” X 1/2” 12690 2” X 11/2” X 2” 2” X 11/2” X 11/2” 12691 2” X 11/2” X 11/4” 12692 12693 2” X 11/2” X 1” 12694 2” X 11/2” X 3/4” 12695 2” X 11/4” X 2” 2” X 11/4” X 11/4” 12697 12699 2” X 1” X 2” 12702 2” X 1” X 1” 12704 2” X 3/4” X 2” 12706 2” X 1/2” X 2” 21/2” X 21/2” X 2” 12708 21/2” X 21/2” X 11/2” 12709 21/2” X 21/2” X 11/4” 12710 21/2” X 21/2” X 1” 12711 21/2” X 21/2” X 3/4” 12712 21/2” X 2” X 21/2” 12713 12714 21/2” X 2” X 2” 21/2” X 11/2” X 2” 12717 12719 3” X 3” X 21/2” 12720 3” X 3” X 2” 12721 3” X 3” X 11/2” 12722 3” X 3” X 11/4” 12723 3” X 3” X 1” 12724 3” X 3” X 3/4” 12727 3” X 21/2” X 2” 12729 3” X 2” X 3” 12730 3” X 2” X 2”
Reducing Coupling MFR# MAL14X18CO MAL38X14CO MAL38X18CO MAL12X38CO MAL12X14CO MAL12X18CO MAL34X12CO MAL34X38CO MAL34X14CO MAL34X18CO MAL1X34CO MAL1X12CO MAL1X38CO MAL1X14CO MAL114X1CO MAL114X34CO MAL114X12CO MAL114X38CO MAL112X114CO MAL112X1CO MAL112X34CO MAL112X12CO MAL2X112CO MAL2X114CO MAL2X1CO MAL2X34CO MAL2X12CO MAL212X2CO MAL212X112CO MAL212X114CO MAL212X1CO MAL3X212CO MAL3X2CO MAL3X112CO MAL3X114CO MAL3X1CO
SIZE WEBB# 12789 3/8” X 1/4” 12790 3/8” X 1/8” 12791 1/2” X 3/8” 12792 1/2” X 1/4” 12793 1/2” X 1/8” 12794 3/4” X 1/2” 12795 3/4” X 3/8” 12796 3/4” X 1/4” 12797 3/4” X 1/8” 12798 12799 1” X 3/4” 12800 1” X 1/2” 12801 1” X 3/8” 12802 1” X 1/4” 12803 11/4” X 1” 12804 11/4” X 3/4” 12805 11/4” X 1/2” 12806 11/4” X 3/8” 12808 11/2” X 11/4” 12809 11/2” X 1” 12810 11/2” X 3/4” 12811 11/2” X 1/2” 12813 2” X 11/2” 12814 2” X 11/4” 12815 2” X 1” 12816 2” X 3/4” 12817 2” X 1/2” 12818 21/2” X 2” 12819 21/2” X 11/2” 12820 21/2” X 11/4” 12821 21/2” X 1” 12822 3” X 21/2” 12823 3” X 2” 12824 3” X 11/2” 12825 3” X 11/4” 12826 3” X 1” 1/4” X 1/8”
Floor Flanges MFR# MAL12FLFLG MAL34FLFLG MAL1FLFLG MAL114FLFLG MAL112FLFLG MAL2FLFLG
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
SIZE WEBB# 12879 12880 1” 12881 11/4” 12882 11/2” 12883 2” 12884
1/2” 3/4”
141
7 gas pipe, tubing & fittings
MFR# MAL18X18X14T MAL14X14X18T MAL38X38X14T MAL38X14X14T MAL12X12X1T MAL12X12X34T MAL12X12X38T MAL12X38X12T MAL12X38X38T MAL12X14X12T MAL34X12X12T MAL34X12X34T MAL34X14X34T MAL34X34X114T MAL34X34X12T MAL34X34X14T MAL34X34X1T MAL34X34X38T MAL1X1X12T MAL1X1X112T MA1X1X114T MAL1X1X38T MAL1X1X14T MAL1X34X1T MAL1X34X34T MAL1X34X12T MAL1X12X1T MAL1X12X34T MAL1X12X12T MAL1X14X1T MAL114X114X2T MAL114X114X112T MAL114X114X1T MAL114X114X34T MAL114X114X12T MAL114X1X114T MAL114X1X1T MAL114X1X34T MAL114X1X12T MAL114X34X114T MAL114X34X1T MAL114X34X34T MAL114X12X114T MAL114X12X1T MAL112X112X2T MAL112X112X114T MAL112X112X1T MAL112X112X34T MAL112x112x12T
Reducing Tee (continued)
SECTION
7
Fittings Schedule 40 Nipples
1/8” — 1”
MFR# webb# MFR# webb# MFR# webb# MFR# webb# MFR# webb# 1/8” 1/4” 3/8” 1/2” 3/4” SIZE
MFR# WEBB# 1”
CLOSE NIP18XCLO
NIP1XCLO 14188
14121 NIP14XCLO 14132 NIP38XCLO 14143 NIP12XCLO 14154 NIP34XCLO 14171
1
NIP14X1
11/2
NIP18X112
14122 NIP14X112 14133 NIP38X112
90178 14144 NIP12X112 14155 NIP34X112
14172
14145 NIP12X2
14173
2
NIP18X2
14123 NIP14X2
21/2
NIP18X212
14124 NIP14X212 14135 NIP38X212 14146 NIP12X212 14157 NIP34X212 14174
14134 NIP38X2
NIP1X212
14190
3
NIP18X3
14125 NIP14X3
NIP1X3
14191
14136 NIP38X3
14147 NIP12X3
14156 NIP34X2 14158 NIP34X3
14175
NIP1X2
14189
31/2
NIP18X312
14126 NIP14X312 14137 NIP38X312 14148 NIP12X312 14159 NIP34X312 14176
NIP1X312
14192
4
NIP18X4
14127 NIP14X4
NIP1X4
14193
14138 NIP38X4
14149 NIP12X4
14160 NIP34X4
14177
41/2
NIP18X412
14128 NIP14X412 14139 NIP38X412 14150 NIP12X412 14161 NIP34X412 14178
NIP1X412
14194
5
NIP18X5
14129 NIP14X5
NIP1X5
14195
14140 NIP38X5
14151 NIP12X5
14162 NIP34X5
14179
51/2
NIP18X512
14130 NIP14X512 14141 NIP38X512 14152 NIP12X512 14163 NIP34X512 14180
NIP1X512
14196
6
NIP18X6
14131 NIP14X6
NIP1X6
14197
61/2
NIP12X612 90214 NIP34X612 86309
7
NIP18X7
NIP1X7
14198
71/2
NIP12X712 225065 NIP1X8
14199
NIP1X9
14200
NIP1X10
14201
110506 NIP14X7 89010 NIP14X8
14142 NIP38X6 93181 NIP38X7 90181 NIP38X8
14153 NIP12X6 67730 NIP12X7
14165 NIP34X7
14182
8
NIP18X8
9
NIP14X9
10
NIP18X10
90179 NIP38X10
79993 NIP12X10
14167 NIP34X9
14183
91/2
153238 NIP14X10
213167 NIP12X9
14166 NIP34X8
14181
81/2
86243 NIP38X9
110509 NIP12X8
14164 NIP34X6
14168 NIP34X10
14184 14185
101/2 11
NIP14X11 206628 NIP38X11
90199 NIP12X11
14169 NIP34X11
14186
NIP1X11
14202
90180 NIP38X12I 153004 NIP12X12
14170 NIP34X12
14187
NIP1X12
14203
14808
12
NIP14X12
13
14
15
16
17
171/2 18 19 20 21 22 24 26 27 28 30 36 40 42 43 48 53 54 60
NIP14X18 14776 NIP38X18 14784 NIP12X18 14792 NIP34X18 14800 NIP1X18
142
NIP34X20
90233
NIP14X24 14777 NIP38X24 14785 NIP12X24 14793 NIP34X24 14801
NIP1X24
NIP12X30 14794 NIP34X30 14802 NIP1X30 NIP14X36 14779 NIP12X36 14795 NIP34X36 14803 NIP1X36 NIP14X48 14781 NIP12X48 14797 NIP34X48 14805 NIP1X48 NIP12X60 14799 NIP34X60 14807 NIP1X60
Gas Equipment Catalog
14809
14810 14811
14813
14815
victormfg.com
SECTION
7
Fittings
Schedule 40 Nipples (continued)
11/4” — 3”
MFR# webb# MFR# webb# MFR# webb# MFR# webb# MFR# webb# 11/2” 2” 21/2” 3” SIZE 11/4”
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
14264
14265 14266 14267 14268 14269 14270 14271 14272 14273 14274 14275 14276 14277
67324
67325
67326 67327
143
7 gas pipe, tubing & fittings
LOSE NIP114XCLO 14204 NIP112XCLO 14219 NIP2XCLO C 14235 NIP212XCLO 14250 NIP3XCLO 1 2 NIP114X2 14205 NIP112X2 14220 21/2 NIP114X212 14206 NIP112X212 14221 NIP2X212 14236 3 NIP114X3 14207 NIP112X3 14222 NIP2X3 14237 NIP212X3 14251 NIP3X3 31/2 NIP114X312 14208 NIP112X312 14223 NIP2X312 14238 NIP212X312 14252 NIP3X312 4 NIP114X4 14209 NIP112X4 14224 NIP2X4 14239 NIP212X4 14253 NIP3X4 41/2 NIP114X412 14210 NIP112X412 14225 NIP2X412 14240 NIP212X412 14254 NIP3X412 5 NIP114X5 14211 NIP112X5 14226 NIP2X5 14241 NIP212X5 14255 NIP3X5 51/2 NIP114X512 14212 NIP112X512 14227 NIP2X512 14242 NIP212X512 14256 NIP3X512 6 NIP114X6 14213 NIP112X6 14228 NIP2X6 14243 NIP212X6 14257 NIP3X6 61/2 7 NIP114X7 14214 NIP112X7 14229 NIP2X7 14244 NIP212X7 14258 NIP3X7 71/2 8 NIP114X8 14215 NIP112X8 14230 NIP2X8 14245 NIP212X8 14259 NIP3X8 81/2 9 NIP114X9 14216 NIP112X9 14231 NIP2X9 14246 NIP212X9 14260 NIP3X9 91/2 10 NIP114X10 30269 NIP112X10 14232 NIP2X10 14247 NIP212X10 14261 NIP3X10 101/2 11 NIP114X11 14217 NIP112X11 14233 NIP2X11 14248 NIP212X11 14262 NIP3X11 12 NIP114X12 14218 NIP112X12 14234 NIP2X12 14249 NIP212X12 14263 NIP3X12 16 17 171/2 18 NIP114X18 14816 NIP112X18 14824 NIP2X18 14832 NIP212X18 67733 NIP3X18 21 22 24 NIP114X24 14817 NIP112X24 14825 NIP2X24 14833 NIP212X24 86476 NIP3X24 27 28 30 NIP114X30 14818 NIP112X30 14826 NIP2X30 14834 NIP212X30 200226 NIP3X30 36 NIP114X36 14819 NIP112X36 14827 NIP2X36 14835 NIP3X36 40 43 48 NIP114X48 14821 NIP112X48 14829 NIP2X48 14837 53 60 NIP114X60 14823 NIP2X60 14839
SECTION
7
Fittings Forged Steel Fittings, 3000# Socket Weld
45° Elbow
Tee
mfr# size
webb#
F/S12453SW
1/2”
8933
F/S34453SW
3/4”
8934
F/S1453SW
1”
8935
F/S114453SW
11/4”
8936
F/S112453SW
11/2”
8937
F/S2453SW
2”
8938
F/S212453SW
21/2”
8939
F/S3453SW
3”
8940
90° Elbow mfr# size
webb#
Reducer Coupling
mfr# size
webb#
1/2”
8945
F/S34T3SW
3/4”
8946
F/S12X38R3SW
1/2” X 3/8”
34915
F/S34X14CO3SW
3/4” X 1/4”
8986
86648
F/S1X12T3SW
1” X 1” X 1/2”
F/S114T3SW
11/4”
8948
F/S34X38R3SW
3/4” X 3/8”
34928
F/S112T3SW
11/2”
8949
F/S34X12R3SW
3/4” X 1/2”
34927
F/S2T3SW
2”
8950
F/S1X14CO3SW
1” X 1/4”
8991
F/S212T3SW
21/2”
8951
F/S1X38CO3SW
1” X 3/8”
8990
F/S3T3SW
3”
8952
F/S1X12R3SW
1” X 1/2”
34918
F/S1X34R3SW
1” X 3/4”
34919
F/S34X12T3SW
3/4” X 3/4” X 1/2”
177016
F/S112X1T3SW
11/2” X 11/2” X 1”
77863
F/S114X12R3SW
11/4” X 1/2”
34910
F/S2X1T3SW
2” X 2” X 1”
77864
F/S114X34R3SW
11/4” X 3/4”
34912
F/S2X112T3SW
2” X 11/2”
90134
F/S114X1R3SW
11/4” X 1”
34911
11/2” X 1/2”
34905
F/S1T3SW
1”
8947
F/S112X12R3SW
F/S112X34T3SW
11/2” X 11/2” X 3/4” 77862
F/S112X34R3SW
11/2” X 3/4”
34908
F/S112X1R3SW
11/2” X 1”
34906
8921
F/S34903SW
3/4”
8922
F/S1903SW
1”
8923
F/S114903SW
11/4”
8924
F/S112903SW
11/2”
8925
F/S2903SW
2”
8926
F/S212903SW
21/2”
8927
F/S12X14I3SW
1/2” X 1/4”
30641
F/S3903SW
3”
8928
F/S12X38ISW
1/2” X 3/8”
9050
F/S34X14I3SW
3/4” X 1/4”
9054
F/S34X38I3SW
3/4” X 3/8”
9053
F/S34X12I3SW
3/4” X 1/2”
9052
webb#
F/S12CA3SW
1/2”
9041
F/S34CA3SW
3/4”
9042
F/S1CA3SW
1”
9043
F/S114CA3SW
11/4”
9044
F/S112CA3SW
11/2”
9045
F/S2CA3SW
2”
9046
F/S212CA3SW
21/2”
F/S3CA3SW
3”
81754 9048
Cross
34914
F/S12T3SW
1/2”
mfr# size
webb#
1/2” X 1/4”
F/S12X14R3SW
F/S12903SW
Cap
mfr# size
F/S2X112T3SW
2” X 2” X 11/2”
90134
Insert mfr# size
webb#
F/S1X38I3SW
1” X 3/8”
9058
F/S1X12I3SW
1” X 1/2”
9057
F/S1X34I3SW
1” X 3/4”
9056
F/S114X12I3SW
11/4” X 1/2”
9063
F/S114X34I3SW
11/4” X 3/4”
30642
F/S114X1I3SW
11/4” X 1”
9061
F/S112X12I3SW
11/2” X 1/2”
9069
F/S112X34I3SW
11/2” X 3/4”
9068
F/S112X1I3SW
11/2” X 1”
9067
F/S112X114I3SW
11/2” X 11/4”
9066
F/S2X112I3SW
2” X 11/2”
9072
F/S2X114I3SW
2” X 11/4”
9073
F/S2X1I3SW
2” X 1”
9074
F/S2X34I3SW
2” X 3/4”
9075 9076
F/S112X114R3SW
11/2” X 11/4” 34903
F/S2X112R3SW
2” X 11/2”
34921
F/S2X114R3SW
2” X 11/4”
34922
F/S2X1R3SW
2” X 1”
9006
F/S2X34R3SW
2” X 3/4”
9007
F/S2X12R3SW
2” X 1/2”
9008
F/S212X2R3SW
21/2” X 2”
81774
F/S212X112R3SW
21/2” X 11/2” 202425
F/S212X114CO3SW 21/2” X 11/4” 200481
Union mfr# size
webb#
F/S12UN3SW
1/2”
9109
F/S34UN3SW
3/4”
9110
F/S1UN3SW
1”
9111
F/S114UN3SW
11/4”
9112
F/S112UN3SW
11/2”
9113
F/S2UN3SW
2”
9114
F/S212UN3SW
21/2”
9115
F/S3UN3SW
3”
9116
Reducing Elbow
F/S2X12I3SW
2” X 1/2”
F/S1CR3SW
1”
84306
F/S212X2I3SW
21/2” X 2”
200488
F/S34X12903SW
3/4” X 1/2”
172849
F/S2CRS3SW
2”
77868
F/S3X212I3SW
3” X 21/2”
69452
F/S1X12903SW
1” X 1/2”
172938
mfr# size
144
webb#
Gas Equipment Catalog
mfr# size
webb#
victormfg.com
SECTION
7
Fittings
Forged Steel Fittings
Flange Accessories
3000# Socket Weld
2H Nuts MFR#
Coupling
Half Coupling
mfr# size webb# F/S12CO3SW F/S34CO3SW F/S1CO3SW F/S114CO3SW F/S112CO3SW F/S2CO3SW F/S212CO3SW F/S3CO3SW
1/2” 3/4”
1” 11/4” 11/2” 2” 21/2” 3”
8957 8958 8959 8960 8961 8962 8963 8964
mfr# size webb# F/S12HCO3SW 1/2” F/S34HCO3SW 3/4” F/S1HCO3SW 1” F/S114HCO3SW 11/4” F/S112HCO3SW 11/2” F/S2HCO3SW 2” F/S212HCO3SW 21/2” F/S3HCO3SW 3”
8969 8970 8971 8972 8973 8974 8975 8976
Socket Welding Flanges Class 300
mfr# size webb# Threaded or Screwed Flanges W/F12300THDFLG 1/2” 27934 W/F34300THDFLG 3/4” 27935 W/F1300THDFLG 1” 27936 W/F114300THDFLG 11/4” 27937 W/F112300THDFLG 11/2” 73679 W/F2300THDFLG 2” 27939 W/F212300THDFLG 21/2” 27940 W/F3300THDFLG 3” 27941 W/F4300THDFLG 4” 27942 W/F6300THDFLG 6” 27943 Blind Flanges W/F12300BLFLG 1/2” 27944 W/F34300BLFLG 3/4” 27945 W/F1300BLFLG 1” 27946 W/F114300BLFLG 11/4” 27947 W/F112300BLFLG 11/2” 27948 W/F2300BLFLG 2” 27949 W/F212300BLFLG 21/2” 27950 W/F3300BLFLG 3” 27951 W/F4300BLFLG 4” 27952 W/F5300BLFLG 5” 27953 W/F6300BLFLG 6” 27954 W/F8300BLFLG 8” 27955 W/F10300BLFLG 10” 27956 W/F12I300BLFLG 12” 27957 Gaskets for SWG 300# Flange 1/2” 55404 3” 55411 3/4” 55405 4” 55413 1” 55406 5” 55414 55407 6” 55415 11/4” 55408 8” 55416 11/2” 2” 55409 10” 55417 55410 12” 55418 21/2”
size
Webb#
1/2”
119129 119130 119131 119132
5/8” 3/4” 7/8”
1”, 11/8” studs, available upon request.
B7 Studs MFR# hgr12x2b7 hgr12x214b7 hgr12x212b7 hgr12x234b7 hgr58x212b7 hgr58x234b7 hgr58x3b7 hgr58x314b7 hgr58x312b7 hgr58x375b7 hgr34x3b7 hgr34x314b7 hgr34x312b7 hgr34x334b7 hgr34x4b7 hgr34x414b7 hgr78x4b7 hgr78x434b7
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
size
Webb#
1/2” X 2”
119109 119110 119111 119112 119113 119114 119115 119116 119117 424777 119118 119119 119120 119121 119122 119123 119124 119126
1/2” X 21/4” 1/2” X 21/2” 1/2” X 23/4” 5/8” X 21/2” 5/8” X 23/4” 5/8” X 3” 5/8” X 31/4” 5/8” X 31/2” 5/8” X 33/4” 3/4” X 3” 3/4” X 31/4” 3/4” X 31/2” 3/4” X 33/4” 3/4” X 4” 3/4” X 41/4” 7/8” X 4” 7/8” X 43/4”
7 gas pipe, tubing & fittings
mfr# size webb# Weld Neck Flanges 27896 W/F12300WNFLG 1/2” 27897 W/F34300WNFLG 3/4” W/F1300WNFLG 1” 27898 W/F114300WNFLG 11/4” 27899 W/F112300WNFLG 11/2” 27900 W/F2300WNFLG 2” 27901 W/F212300WNFLG 21/2” 27902 W/F3300WNFLG 3” 27903 W/F4300WNFLG 4” 27904 W/F5300WNFLG 5” 27905 W/F6300WNFLG 6” 27906 W/F8300WNFLG 8” 27907 W/F10300WNFLG 10” 27908 W/F12I300WNFLG 12” 27909 Slip On Flanges 27915 W/F12300SOFLG 1/2” 27916 W/F34300SOFLG 3/4” W/F1300SOFLG 1” 27917 W/F114300SOFLG 11/4” 27918 W/F112300SOFLG 11/2” 27919 W/F2300SOFLG 2” 27920 W/F212300SOFLG 21/2” 27921 W/F3300SOFLG 3” 27922 W/F4300SOFLG 4” 27923 W/F5300SOFLG 5” 27924 W/F6300SOFLG 6” 27925 W/F8300SOFLG 8” 27926 W/F10300SOFLG 10” 27927 W/F12I300SOFLG 12” 27928 Gaskets for Manway 150# SWG160010008 16” 308728 SWG180010017 18” 202009 SWG200010017 20” 202010
HGR12NUT2H HGR58NUT2H HGR34NUT2H HGR78NUT2H
145
SECTION
7
Fittings Flange Size Chart for Stud/Bolt Length Pipe size 1/2” 3/4” 1” 11/4” 11/2” 2” 21/2” 3” 31/2” 4” 5” 6” 7” 10” 12” 14” 16” 18” 20” 22” 24” 26” 30” 34” 36” 42”
diameter of bolt circle 25/8” 31/4” 31/2” 37/8” 41/2” 5” 57/8” 65/8” 71/4” 77/8” 91/4” 105/8” 13” 151/4” 173/4” 201/4” 221/2” 243/4” 27” 291/4” 32” 341/2” 391/4” 431/2” 46” 523/4”
diameter of bolt 1/2” 5/8” 5/8” 5/8” 3/4” 5/8” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 1” 11/8” 11/8” 11/4” 11/4” 11/4” 11/2” 11/2” 15/8” 13/4” 17/8” 2” 2”
Forged Steel Fittings Threaded
45° Elbow mfr# size webb# 3000# F/S14453SE 1/4” 8700 3/8” 8689 F/S38903SE 1/2” 8702 F/S12453SE 3/4” 8703 F/S34453SE F/S1453SE 1” 8704 8705 F/S114453SE 11/4” 8706 F/S112453SE 11/2” F/S2453SE 2” 8707 F/S3453SE 3” 154532 2000# 1/4” 8665 F/S14452SE 8670 F/S114452SE 11/4” F/S3452SE 3” 8674
146
90° Elbow mfr# size webb# 3000# F/S14903SE 1/4” 8688 1/2” 8690 F/S12903SE 3/4” 8691 F/S34903SE F/S1903SE 1” 8692 8693 F/S114903SE 11/4” 8694 F/S112903SE 11/2” F/S2903SE 2” 8695 8696 F/S212903SE 21/2” F/S3903SE 3” 8697 2000# F/S14902SE 1/4” 8654 1/2” 8656 F/S12902SE F/S2902SE 2” 8661 3/4” 8657 F/S34902SE F/S1902SE 1” 8658 8659 F/S114902SE 11/4” 8660 F/S112902SE 11/2” F/S2902SE 2” 8661 8662 F/S212902SE 21/2” F/S3902SE 3” 8663
Gas Equipment Catalog
no. of bolts 4 4 4 4 4 8 8 8 8 8 8 12 12 16 16 20 20 24 24 24 24 28 28 28 32 36
length of stud
1/16” raised face
90° Street Elbow — 3000# F/S14S903SE 1/4” F/S38S903SE 3/8” F/S12S903SE 1/2” F/S34S903SE 3/4” F/S1S903SE 1” F/S114S903SE 11/4” F/S112S903SE 11/2” F/S2S903SE 2”
bolt length 2” 21/2” 21/2” 23/4” 3” 3” 31/4” 31/2” 33/4” 33/4” 4” 41/4” 43/4” 51/4” 53/4” 6” 61/2” 63/4” 7” 71/2” 73/4” 83/4” 10” 103/4” 111/4” 131/2”
21/2” 23/4” 3” 3” 31/2” 31/4” 33/4” 4” 41/4” 41/4” 41/2” 43/4” 51/4” 6” 61/2” 63/4” 71/4” 71/2” 8” 83/4” 9” 10” 111/4” 121/4” 123/4” 133/4”
8723 8724 8725 8726 8727 8728 8729 8730
Reducing Elbow mfr# size webb# 3000# F/S1X34903SE 1” X 3/4” 216219 F/S1X12903SE 1” X 1/2” 210687 F/S2X112903SE 2” X 11/2” 206543
Square Head Plug mfr# size webb# 3000# F/S14PL 1/4” 8828 3/8” 8829 F/S38PL 1/2” 8830 F/S12PL 3/4” 8831 F/S34PL F/S1PL 1” 8832 8833 F/S114PL 11/4” 8834 F/S112PL 11/2” F/S2PL 2” 8835 8836 F/S212PL 21/2” F/S3PL 3” 8837
Coupling mfr# size webb# 3000# F/S14CO3SE 1/4” 8732 8733 F/S38CO3SE 3/8” 8734 F/S12CO3SE 1/2” 8735 F/S34CO3SE 3/4” F/S1CO3SE 1” 8736 8737 F/S114CO3SE 11/4” 8738 F/S112CO3SE 11/2” F/S2CO3SE 2” 8739 8740 F/S212CO3SE 21/2” F/S3CO3SE 3” 8741
Cross
Cross mfr# size webb# 3000# F/S38CR3SE 3/8” 222407 180085 F/S12CR3SE 1/2” 187210 F/S34CR3SE 3/4” F/S1CR3SE 1” 110425 F/S114CR3SE 11/4” 200465 F/S112CR3SE 11/2” 184610 F/S2CR3SE 2” 223961 F/S3CR3SE 3” 187211
victormfg.com
SECTION
7
Fittings
Forged Steel Fittings – Threaded Bushing
mfr# size webb# 3000# F/S14T3SE 1/4” 8712 F/S38T3SE 3/8” 8713 F/S12T3SE 1/2” 8714 F/S34T3SE 3/4” 8715 F/S1T3SE 1” 8716 F/S114T3SE 11/4” 8717 F/S112T3SE 11/2” 8718 F/S2T3SE 2” 8719 F/S212T3SE 21/2” 8720 2000# F/S14T2SE 1/4” 8676 F/S38T2SE 3/8” 8677 F/S12T2SE 1/2” 8678 F/S34T2SE 3/4” 8679 F/S1T2SE 1” 8680 F/S114T2SE 11/4” 8681 F/S112T2SE 11/2” 8682 F/S2T2SE 2” 8683 F/S212T2SE 21/2” 8684 F/S3T2SE 3” 8685
Cap mfr# size webb# 3000# F/S14CA3SE 1/4” 8816 F/S38CA3SE 3/8” 8817 F/S12CA3SE 1/2” 8818 F/S34CA3SE 3/4” 8819 F/S1CA3SE 1” 8820 F/S114CA3SE 11/4” 8821 F/S112CA3SE 11/2” 8822 F/S2CA3SE 2” 8823 F/S212CA3SE 21/2” 8824 F/S3CA3SE 3” 8825
Reducer Coupling
Half Coupling
mfr# size webb# 3000# F/S14X18R3SE 1/4” X 1/8” 8755 F/S38X14R3SE 3/8” X 1/4” 8756 F/S38X18RED3SE 3/8” X 1/8” 8757 F/S12X14R3SE 1/2” X 1/4” 8759 F/S12X38R3SE 1/2” X 3/8” 8758 F/S34X14R3SE 3/4” X 1/4” 166093 F/S34X38R3SE 3/4” X 3/8” 8762 F/S34X12R3SE 3/4” X 1/2” 8761 F/S1X14RED3SE 1” X 1/4” 8768 F/S1X12R3SE 1” X 1/2” 8766 F/S1X34R3SE 1” X 3/4” 8765 F/S114X12R3SE 11/4” X 1/2” 34909 F/S114X34R3SE 11/4” X 3/4” 8771 F/S114X1R3SE 11/4” X 1” 8770 F/S112X12R3SE 11/2” X 1/2” 34904 F/S112X34R3SE 11/2” X 3/4” 34907 F/S112X1R3SE 11/2” X 1” 8776 F/S112X114R3SE 11/2” X 11/4” 8775 F/S2X12R3SE 2” X 1/2” 34923 F/S2X34R3SE 2” X 3/4” 34925 F/S2X1R3SE 2” X 1” 34924 F/S2X114R3SE 2” X 11/4” 8782 F/S2X112R3SE 2” X 11/2” 8781 F/S212X2R3SE 21/2” X 2” 81759 F/S212X112R3SE 21/2” X 11/2” 81756 F/S212X1R3SE 21/2” X 1” 209413 F/S3X212R3SE 3” X 21/2” 81764 F/S3X2R3SE 3” X 2” 155613 F/S3X112R3SE 3” X 11/2” 209415
mfr# size webb# 3000# F/S14HCO3SE 1/4” 8744 F/S38HCO3SE 3/8” 8745 F/S12HCO3SE 1/2” 8746 F/S34HCO3SE 3/4” 8747 F/S1HCO3SE 1” 8748 F/S114HCO3SE 11/4” 8749 F/S112HCO3SE 11/2” 8750 F/S2HCO3SE 2” 8751 F/S212HCO3SE 21/2” 8752 F/S3HCO3SE 3” 110427
Union mfr# size webb# 3000# F/S14UN3SE 1/4” 9096 F/S38UN3SE 3/8” 9097 F/S12UN3SE 1/2” 9098 F/S34UN3SE 3/4” 9099 F/S1UN3SE 1” 9100 F/S114UN3SE 11/4” 9101 F/S112UN3SE 11/2” 9102 F/S2UN3SE 2” 9103 F/S212UN3SE 21/2” 9104 F/S3UN3SE 3” 9105
Schedules 40 & 80 Black Pipe S40 Plain End
mfr# size webb# Plain End D/P14BPE 1/4” 179384 D/P38BPE 3/8” 79878 D/P12BPE 1/2” 45484 D/P34BPE 3/4” 45500 D/P1BPE 1” 45518 D/P114BPE 11/4” 45533 D/P112BPE 11/2” 45488 D/P2BPE 2” 45504 D/P212BPE 21/2” 45522 D/P3BPE 3” 45474 D/P4BPE 4” 45508
S40 Threaded
mfr# size webb# Threaded & Capped Ends D/P38BTC 3/8” 45473 D/P12BTC 1/2” 45490 D/P34BTC 3/4” 45507 D/P1BTC 1” 45524 D/P114BTC 11/4” 45477 D/P112BTC 11/2” 45493 D/P2BTC 2” 45511 D/P212BTC 21/2” 45527 D/P3BTC 3” 45480 D/P4BTC 4” 45514
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
S80 mfr# size webb# Plain End D/P14XHBPE 1/4” 45475 D/P12XHBPE 1/2” 45525 D/P34XHBPE 3/4” 45478 D/P1XHBPE 1” 45494 D/P114XHBPE 11/4” 45512 D/P112XHBPE 11/2” 45528 D/P2XHBPE 2” 45482 D/P212XHBPE 21/2” 45498 D/P3XHBPE 3” 45516 D/P4XHBPE 4” 45486
147
7 gas pipe, tubing & fittings
mfr# size webb# 3000# F/S14X18BU 1/4” X 1/8” 8851 F/S38X18BU 3/8” X 1/8” 8853 F/S38X14BU 3/8” X 1/4” 8852 F/S12X18BU 1/2” X 1/8” 8856 F/S12X14BU 1/2” X 1/4” 8855 F/S12X38BU 1/2” X 1/8” 8854 F/S34X18BU 3/4” X 1/8” 8860 F/S34X14BU 3/4” X 1/4” 8859 F/S34X38BU 3/4” X 3/8” 8858 F/S34X12BU 3/4” X 1/2” 8857 F/S1X18BU 1” X 1/8” 8865 F/S1X14BU 1” X 1/4” 8864 F/S1X38BU 1” X 1/8” 8863 F/S1X12BU 1” X 1/2” 8862 F/S1X34BU 1” X 3/4” 8861 F/S114X14BU 11/4” X 1/4” 8870 F/S114X38BU 11/4” X 3/8” 8869 F/S114X12BU 11/4” X 1/2” 8868 F/S114X34BU 11/4” X 3/4” 8867 F/S114X1BU 11/4” X 1” 8866 F/S112X14BU 11/2” X 1/4” 8877 F/S112X38BU 11/2” X 3/8” 8876 F/S112X12BU 11/2” X 1/2” 8875 F/S112X34BU 11/2” X 3/4” 8874 F/S112X1BU 11/2” X 1” 8873 F/S112X114BU 11/2” X 11/4” 8872 F/S2X14BU 2” X 1/4” 8885 F/S2X38BU 2” X 3/8” 8884 F/S2X12BU 2” X 1/2” 8883 F/S2X34BU 2” X 3/4” 8882 F/S2X1BU 2” X 1” 8881 F/S2X114BU 2” X 11/4” 8880 F/S2X112BU 2” X 11/2” 8879 F/S212X14BU 21/2” X 1/4” 8894 F/S212X34BU 21/2” X 3/4” 8891 F/S212X1BU 21/2” X 1” 8890 F/S212X114BU 21/2” X 11/4” 8889 F/S212X112BU 21/2” X 11/2” 8888 F/S212X2BU 21/2” X 2” 8887 F/S3X12BU 3” X 1/2” 8902 F/S3X1BU 3” X 1” 8900 F/S3X114BU 3” X 11/4” 8899 F/S3X112BU 3” X 11/2” 8898 F/S3X2BU 3” X 2” 8897 F/S3X212BU 3” X 21/2” 8896
Tee
SECTION
7
Fittings Schedule 80 Nipples MFR# webb# MFR# SIZE 1/4” CLOSE 11/2 2 21/2 3 31/2 4 41/2 5 51/2 6 7 8 9 10 11 12
3/8”
1/4” - 1” webb# MFR#
1/2”
webb# MFR#
3/4”
webb# MFR#
1”
NIP14XCLOXH 14541 NIP38XCLOXH 14558 NIP12XCLOXH 14575 NIP34XCLOXH 14592 NIP1XCLOXH NIP14X112XH 14542 NIP38X112XH 14559 NIP12X112XH 14576 NIP34X112XH 14593 NIP14X2XH 14543 NIP38X2XH 14560 NIP12X2XH 14577 NIP34X2XH 14594 NIP1X2XH NIP14X212XH 14544 NIP38X212XH 14561 NIP12X212XH 14578 NIP34X212XH 14595 NIP1X212XH NIP14X3XH 14545 NIP38X3XH 14562 NIP12X3XH 14579 NIP34X3XH 14596 NIP1X3XH NIP14X312XH 14546 NIP38X312XH 14563 NIP12X312XH 14580 NIP34X312XH 14597 NIP1X312XH NIP14X4XH 14547 NIP38X4XH 14564 NIP12X4XH 14581 NIP34X4XH 14598 NIP1X4XH NIP14X412XH 14548 NIP38X412XH 14565 NIP12X412XH 14582 NIP34X412XH 14599 NIP1X412XH NIP14X5XH 14549 NIP38X5XH 14566 NIP12X5XH 14583 NIP34X5XH 14600 NIP1X5XH NIP14X512XH 14550 NIP38X512XH 14567 NIP12X512XH 14584 NIP34X512XH 14601 NIP1X512XH NIP14X6XH 14551 NIP38X6XH 14568 NIP12X6XH 14585 NIP34X6XH 14602 NIP1X6XH NIP34X7XH 14603 NIP34X8XH 14604 NIP1X8XH NIP34X10XH 203165 NIP34X12XH 203167 NIP1X12XH
webb# 14609 14610 14611 14612 14613 14614 14615 14616 14617 14618 14620
14624
11/4” - 3” MFR# webb# MFR# webb# SIZE 11/4” 11/2” CLOSE NIP114XCLOXH 14625 NIP112XCLOXH 14641 11/2 2 NIP114X2XH 14626 NIP112X2XH 14642 21/2 NIP114X212XH 14627 NIP112X212XH 14643 3 NIP114X3XH 14628 NIP112X3XH 14644 31/2 NIP114X312XH 14629 NIP112X312XH 14645 4 NIP114X4XH 14630 NIP112X4XH 14646 41/2 NIP114X412XH 14631 NIP112X412XH 14647 5 NIP114X5XH 14632 NIP112X5XH 14648 51/2 NIP114X512XH 14633 NIP112X512XH 14649 6 NIP114X6XH 14634 NIP112X6XH 14650 7 NIP114X7XH 14635 NIP112X7XH 225118 8 NIP114X8XH 14636 NIP112X8XH 14652 9 NIP114X9XH 225124 NIP112X9XH 223049 10 NIP114X10XH 187212 NIP112X10XH 223048 11 12 NIP114X12IXH 187213 NIP112X12XH 14656
MFR#
2” NIP2XCLOXH
NIP2X212XH NIP2X3XH NIP2X312XH NIP2X4XH NIP2X412XH NIP2X5XH NIP2X512XH NIP2X6XH NIP2X7XH NIP2X8XH NIP2X9XH NIP2X10XH NIP2X11XH NIP2X12XH
Concentric Swedge Nipples XH Mfr# NIPCS1X34XH NIPCS114X1XH NIPCS112X114XH NIPCS2X114XH NIPCS2X112XH NIPCS3X2XH NIPES2X112XH
148
2” X 11/2” Nipple Eccentric Swedge
21/2” 14657 NIP212XCLOXH
webb# MFR#
3” 14672 NIP3XCLOXH
14658 14659 NIP212X3XH 14673 14660 NIP212X312XH 14674 14661 NIP212X4XH 14675 14662 NIP212X412XH 14676 14663 NIP212X5XH 14677 14664 NIP212X512XH 14678 14665 NIP212X6XH 14679 14666 NIP212X7XH 210655 14667 NIP212X8XH 110508 187216 14669 187214 14671
NIP3X3XH NIP3X312XH NIP3X4XH NIP3X412XH NIP3X5XH NIP3X512XH NIP3X6XH NIP3X7XH NIP3X8XH NIP3X9XH NIP3X11XH NIP3X12XH
webb# 14686
14687 14688 14689 14690 14691 152712 14693 192822 192823 187218 187217 14699
XH Nipple Sets (1 of each)
Description webb# 187219 1” X 3/4” Nipple Concentric Swedge 187220 11/4” X 1” Nipple Concentric Swedge 11/2” X 11/4” Nipple Concentric Swedge 187221 187222 2” X 11/4” Nipple Concentric Swedge 187223 2” X 11/2” Nipple Concentric Swedge 3” X 2” Nipple Concentric Swedge 187224
Eccentric Swedge Nipples XH
webb# MFR#
190099
Gas Equipment Catalog
Mfr# NIP14XCLO-6XH NIP38XCLO-6XH NIP12XCLO-6XH NIP34XCLO-6XH NIP1XCLO-6XH NIP114XCLO-6XH NIP112XCLO-6XH NIP2XCLO-6XH
Description
webb# 73366 3/8” X CLOSE-6” Nipple Set Black XH 73367 1/2” X CLOSE-6” Nipple Set Black XH 52875 3/4” X CLOSE-6” Nipple Set Black XH 52876 1” X CLOSE-6” Nipple Set Black XH 52877 93049 11/4” X CLOSE-6” Nipple Set Black XH 93050 11/2” X CLOSE-6” Nipple Set Black XH 2” X CLOSE-6” Nipple Set Black XH 93051 1/4” X CLOSE-6” Nipple Set Black XH
victormfg.com
SECTION
8
Ignition Modules Gas Ignition Controls Universal Ignition Controls
780-001
Robertshaw’s Universal Ignition Control Uni-Kits feature a flame sense circuit that will work equally well on a one rod (local sense) or a two rod (remote sense) application. 780-001 (Nonlockout) The automatic recycle features assure that, in the event of flame failure, main gas is disabled and the spark repetition sequence is restarted until pilot gas is ignited. Only after pilot ignition has been re-established can main gas be returned to the burner. 780-002 (Lockout) These kits have a lockout feature to shut off all gas in the furnace, should pilot ignition fail to occur after a predetermined time period. The 780-002 provides 3 tries for ignition, each ignition period is 90 seconds followed by a 6 minute time delay between ignition attempts. After 3 tries if no pilot flame is sensed, unit goes into lockout and must be reset at the thermostat. mfr# 780-001 780-002
description Non-Lockout Lockout
webb# 118693 75124
780 Series Hot Surface Ignition Module The 780 Series Hot Surface Ignition Modules are designed for use on gas fired heating systems The system acts on a demand for heat by a switch or thermostat to supply power to the ignition control. On non pre-purge models, the ignitor will be energized immediately and remain on for wither of two optional selected ignitor heat-up time approximately 17 or 34 seconds. For models with the prepurge option, there is a time delay equal to the heat-up time selected before the ignitor is energized. 780-785
mfr# 780-785 780-787
description Gas Ignition Control Gas Ignition Control
webb# 167059 246666
780-910 Universal Hot Surface Ignition Module Uni-Kit®
780-910
mfr# 780-910
description Universal Hot Surface Ignition Module
webb# 155174
Test Equipment 900-575 Module Tester
The 900-575 Test Kit is designed specifically for the professional service technician. Now an electronic ignition module — intermittent pilot, direct spark, hot surface can be quickly and accurately diagnosed at the job site. The 900-575 Tester will diagnose all the circuit functions on an I.C.U. Checking for proper sequence of operation and/or failure. No more guessing which part to replace. With the 900-575 change out the defective part the first time, not on a return call back. 900-575
mfr# description 900-575 Ignition Module Tester 720001W Quick Look Tester Q/L
webb# 152947 360275
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
149
8 Gas heating
The 780-910 Universal Hot Surface Ignition Module Uni-Kit is designed for use on gas fired systems. It is equipped with a self diagnostic green LED for quick troubleshooting. The LED indicates if the system is in normal operati on, has gone into lockout, has a weak flame signal, or has an internal error (a defective module).
SECTION
8
Ignition Modules
Replacement Controls and Components Ignition Control Units
780-735
780-015 Add-on lockout module. Using the 780-015 module with 780-715 module will give application lockout timing function for use on LP gas, 60 second timing lockout on pilot and main gas flow. 780-735 Lockout Model. Flame rectification system. Use with gas valves 7000 BDER and 7100 DER. Has 60 second lockout timing. 780-845 Universal lockout model has three 90 second valve trials interrupted by a six minute purge cycle before 100% lockout. mfr# 780-015 780-735 780-845
description Non-Lockout Flame Rectification System Lockout Flame Rectification System Gas Ignition Control
webb# — 73462 167191
Automatic Pilot Relight Kits The Robertshaw 785 Series automatic Pilot Relight Kits are designed for use on rooftop heating equipment, water heaters, boilers, space heaters, unit heaters, dryers, and other commercial, industrial, and residential appliances where the problem of pilot outage may occur. It should only be applied to those systems which already incorporate the necessary pilot-safety control system. 785-001
mfr# 785-001
description Automatic Pilot Relight Kit
webb# 79497
Pilot Relite Control The relite control generates sparks until a pilot flame is sensed between the electrode and ground. When flame current is sensed between the electrode and pilot burner ground, the relite control stops sparking. If the flame is extinguished during the heat call, the relite control will begin sparking the instant the flame goes out.
5059-23
ELECTRICAL mfr# INPUT VOLTAGE RATING 5059-23 24 Vac 0.03 Amps
description Spark Plug and 1/4� Spade Connectors
webb# 118717
Ignition Module for Hot Surface Ignition Systems The Hot Surface ignition Unit is a microprocessor based gas ignition control designed primarily for direct ignition and burner supervision applications such as gas furnaces, boilers, water heaters and other similar devices.
MFR#
50E47-150
50E41-843
Lockout time
Ignitor warm-up time
50E47 Prepurge time (in seconds)
Webb#
4 Seconds
45 Seconds
0 Seconds
152586
50E47-140 50E47-150
17 Seconds 7 Seconds
50E47-170
150
Gas Equipment Catalog
45 Seconds
30 Seconds 0 Seconds
192971 85263 152586
victormfg.com
SECTION
8
Ignition Modules Ignition Controls G600, G670
G600/G760 ignition controls are reliable, proven circuitry replacements for G60, G67 controls. In most cases the replacement controls have mounting configurations identical to the original device. Replacement controls feature precision timing for lockout models. Note: G600/G670 ignition control replacement parts must be used only for field replacement of existing equipment. These replacement parts must not be used for new field applications. MFR#
100% Lockout
G600AX-1C
remarks
Webb#
Yes
24 VAC, Terminal Bard Wiring
97579
No
24 VAC, 1/4” Spade Wiring Connections
105895
No
G670AW-1C
G600
damper plug
Universal Replacement Intermittent Pilot Ignition Control G779
The G779 Universal Replacement Intermittent Pilot ignition Control replaces many existing intermittent pilot controls made by various manufacturers. It is a safety control designed for indirect burner ignition and supervision. The G779 can be used with all gas-fired appliances with a maximum firing rate of 400,000 Btu/hr.
G779
Applications The G779 replaces existing intermittent pilot ignition controls with the following specifications: • Flame detection using flame rectification technology (ability of a flame to conduct and rectify current). • Integral or remote flame sensing. • Non-100% lockout, 100% lockout, or 100% shutoff with continuous retry. • Trial for ignition period greater than or equal to 25 seconds. • Prepurge period less than 1 second. • Pilot burners with flow rates of 1,500 Btu-hr or less. • Operating with or without vent dampers.
8 Gas heating
The G779 is not designed to replace ignition controls with the following specifications: • Pilot flame detection by any means other than flame rectification. • Trial for ignition period of less than 25 seconds. • Prepurge period greater than or equal to 1 second. • Standing pilot applications. Specifications Operating voltage Ignition source Prepurge Number of trials before 100% shutoff Trial time for ignition Retry delay period Flame failure response time Type of gas mfr# G779LHA-1C
24 VAC at 50/60 Hz High voltage spark, cap active discharge Less than one second One 25 Seconds 5 Minutes 0.8 Seconds Natural, Liquified Petroleum (LP), manufactured, mixed or LP gas-air mix
description webb# Universal Intermittent Pilot Ignition Control 110805
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
151
SECTION
8
Ignition Modules Spark Ignitor Q347
Produces spark for direct ignition of main burner. • Includes inner Kanthal electrode with ceramic insulator, bracket and Kanthal ground strap. • Use with S87C, D, K; S89E, F and Q354A. mfr# Rod Angle Q347A1004 Standard Orientation Q347
webb# 188456
Universal Intermittent Pilot Module S8610U
S8610U3009
Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) Intermittent Pilot Ignition Modules. Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers, and other heating appliances. • Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances. • Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed. • For use in single rod of dual rod/remote sense applications. • Includes relay contacts for use with any intermittent pilot has control string with maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended. Ignition Lockout Ignition Trials mfr# Description trial time timing to lockout webb# S8610U3009 Intermittent Pilot Control Continuous Retry 90 Sec. Max. Continuous Retry 74468
Universal Hot Surface Ignition Module S8910U
Provides operating control of a direct ignition system using a 120 Vac hot surface ignitor. • Provides easy field-replacement of a wide range of hot surface ignition modules manufactured by Honeywell, Robertshaw, and White-Rodgers. Refer to the product specifications sheet for specific models that can be replaced by the S8910U. • For 120 VAC (up to 5.0A) hot surface igniter (Norton 201/271 or equivalent). S8910U1000
The S8910U can be used only for direct replacement of specific installed models. Check the product specification sheet before replacing an existing hot surface module with the S8910U. If the existing module is not listed, do not use the S8910U to replace it. Always use the selection tab specified in the product specification sheet for the existing module being replaced. Replacement of an unlisted module or use of a selection tab other than specified can result in appliance malfunction. mfr# Description S8610U1000 Hot Surface Ignition Control
152
Gas Equipment Catalog
Ignition Lockout Ignition Trials trial time timing to lockout webb# 4 Sec. or 7 Sec. 4 Sec. or 7 Sec. 1 or 3 92054
victormfg.com
SECTION
8
Ignition Modules Gas Ignition Modules S89C Hot Surface Ignition Module
Provide electronic control of 120V hot surface ignition systems used in furnaces, boilers and other heating appliances. • S89C is for systems with combination ignitor-sensor. • Use with Norton 201 Hot Surface Ignitors or equivalent. • Lockout after one trial for igniting if main burner fails to ignite. • Reset from thermostat after lockout. mfr# S89C1087 S89C1095
S89C
Lockout timing ignition Trial TIme 6 Sec. 6 Sec. 15 Sec. 15 Sec.
webb# 95080 152200
Y8610U Universal Retrofit Intermittent Pilot Gas Burner ignition Systems Complete kits converting conventional standing pilot system to intermittent pilot system. For use with 24 VAC gas-fired atmospheric furnaces, boiler and heating appliances. • Y8610U kits are for use with natural or LP gas; provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. • Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed. MFR#
Y8610U Y8610U3003
Ignition sequence
typical gas control
Gas type
Webb#
Continuous Retry (after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place)
VR8304M Dual Valve Combination Gas Control
LP/Natural
74467
S9200U1000 Universal Hot Surface Ignition Integrated Furnace Control
MFR#
S9200U1000
AMBIENT TEMP. (F) –40° F to +175° F
PREPURGE
HSI WARMUP TIME
30 seconds
17/27 or 30/30 seconds
HEAT HEAT POST- ON FAN OFF FAN PURGE DELAY DELAY 15 seconds
30 or 60 seconds
60, 90, 120, or 180 seconds
COOL FAN ON DELAY
5 seconds
COOL FAN OFF DELAY
GAS CONTROL USED WITH
Webb#
0 or 60 seconds
Any 24 VAC redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
372843
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
153
8 Gas heating
S9200U1000
Controls a standard induction-type circulating fan motor. • Main burner ignition using a 120V hot surface igniter. • Flame rectification circuit to monitor flame presence. • Monitoring of system pressure switch, high temperature limit, and rollout functions. • Appliance operation/safety requirements controlled via microprocessor. • Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM™ thermostat. • LED system status, performance and diagnostic indication. • Wire harnesses provided for simple replacement of most IFCs and integration with most heating and cooling appliances. • Twinning capability • EnviraCOM™ communication capability to enable local and/or remote system status, diagnostics, troubleshooting, and HVAC system control.
SECTION
8
Gas Valves Water Heating
Domestic, Commercial & Recreational Vehicle Water Heater Thermostat Uni-Kits® 110 Series The 110-Series Water Heater Thermostat Uni-Kit® and Commercial Water Heater Thermostat Uni-Kit were designed for universal replacement applications. All models feature built-in, noncycling Energy Cut-Off (ECO) system to shut off all gas to the water heater in case of excessive water temperatures. All models have a 51/2” sensing element and vary by inlet and outlet size, shank length, regulator type and setting. MFR#
Inlet Size
Outlet size
shank length
PresSure regulator setting
Webb#
13/8”
4.0” W.C. Natural Gas
85376
23/8”
3.5” W.C. Natural Gas
246749
13/8”
3.5” W.C. Natural Gas
73452
110-202 1/2” Pipe
110-206
1/2” Inverted Flare
110-326
110-202
Domestic and Commercial LP Gas Water Heater Thermostat Uni-Kits® The 110 Series Water Heater Uni-Kits® are designed for universal replacement applications. All models feature built-in, non-cycling Energy Cut-Off (ECO) system to shut off all gas to the water heater in case of excessive water temperatures. All models have a 51/2” sensing element and vary by shank length. MFR#
Temp. Setting
INLET size
Outlet Size
Shank Length
PresSure regulator setting
Webb#
Right Hand Thread — Outlet: Replaces Model RPL 110-262
160º
1/2” Inverted
1/2” Pipe
Flare
Preset @ 10.0 (Adjustable from 9” W.C. - 12” W.C.)
13/8”
73449
Left Hand Thread — Outlet: Replaces Model R65RR 110-265
160º
110-285
180º
1/2” Pipe
1/2” Inverted Flare (Left hand Threads)
13/8”
Preset @ 10.0 (Adjustable from 9” W.C. - 12” W.C.)
11/2”
73450 75123
700 (70000GO) Commercial 700-800 Series bleed gas diaphragm valves feature: automatic pilot valve, bleed gas operator, inlet and outlet screens, manual “gas cock” valve, pilot adjusting key, pilot gas filter and pressure regulator (optional by model). Pressure Regulator Factory set at 3.5” W.C. MFR#
INLET size (FPT)
Outlet SizE (FPT)
PresSure regulator setting
Reducer bushings included (NPT) Capacity 3/4” x 1/2”
Webb#
700 “Thermopile” Type Diaphragm Gas Valves 700-885
3/4”
3/4”
None
305,000
2
186756
Gas Water Heater Controls For replacement of standard gas water heater controls with built-in E.C.O. (energy cut-off ). Features • Automatic shut-off of amin and pilot gas in the event of pilot failure. • Pilot gas cock with safe lighting feature. • Pilot gas filter. Specifications Inlet Size: 1/2” NPT Outlet Size: 1/2” Inverted Flare Mounting: 3/4” NPT, 11/4”, shank length, 41/2” bulb insertion length Pilot Connection: 1/2” compression fitting 37C63U-114 MFR# 37C63U-114
154
main burner
pilot
Temp. Range
shank length
Webb#
3.5” W.C.
Adjustable
70° F – 160º F
11/4”
188187
Gas Equipment Catalog
victormfg.com
SECTION
8
Gas Valves Boxed ICON Direct Replacement Gas Controls and Valves Can be utilized as a Direct Replacement on all Atmospheric Vent and Direct Vent Residential and Light Duty Bradford White ICON System™, Robertshaw or White Rodgers models up to 65 gallons* Includes: Pre-assembled ICON Gas Control Valve, Pilot Assembly, Feedline Spring, and Feedline adaptor. Residential Suffix Examples: Natural Gas (FBN, BN, LN, CN, EN) LP Gas (FSX, FCX, CX). Light Duty Commercial Suffix Examples: Natural Gas (FB-3N, B-3N, E3N) LP Gas (FS-3X, C-3X). mfr# description 239-47463-01 Res. (160°F) Direct Replacement Nat. ICON Gas Control Kit 1” Cavity 239-47465-01 Res. (160°F) Direct Replacement LP ICON Gas Control Kit 1” Cavity
webb# 420169 420168
Boxed ICON Universal Replacement Gas Controls and Valves Can be utilized as a Universal Replacement on all Atmospheric Vent and Direct Vent Residential and Light Duty Bradford White ICON System™, Robertshaw or White Rodgers models up to 65 gallons* Includes: Gas Control Cover, Gas Valve Body, 1” Thermowell, 2” Thermowell, 1” Insertion Stick, 2” Insertion Stick, Piezo Igniter, Temperature Sensor, Pilot Assembly, Feedline Spring, and Feedline adaptor. Residential Suffix Examples: Natural Gas (FBN, BN, LN, CN, EN) LP Gas (FSX, FCX, CX). Light Duty Commercial Suffix Examples: Natural Gas (FB-3N, B-3N, E3N) LP Gas (FS-3X, C-3X). mfr# description 239-47851-00 Res. (160°F) Universal Replacement Nat. ICON Gas Control Kit 1” & 2” Cavity 239-47856-00 Res. (160°F) Universal Replacement LP ICON Gas Control Kit 1” & 2” Cavity
webb# 420167 420166
Gas Oven Safeties
1720 (TS) “J” and “K” Magnet Heads
1720-801
mfr# 1720-801 1720-802
description Pilot Size Gas Oven Safety With Tubing Kit – “J” Head 1/8” Pipe, 3/16” Tubing, 1/4” Tubing Gas Oven Safety With Tubing Kit – “K” Head 1/8” Pipe, 3/16” Tubing, 1/4” Tubing
webb# 75107 85431
4020 (FMDA) with Pilot Inlet and Outlet The 4020 Safety Pilot Valves provide gas shutoff in case of pilot outage. When the reset button is depressed, gas will flow to the pilot only. Main gas will not flow until the pilot is operating and the reset button has been released. Pilot inlet and outlet connections are 1/2”tubing, unless otherwise indicated. 100,000 BTU/HR capacity. Ambient Temperature 32° – 350°F. 4020-010
MFR#
main burner
4020-010
48”
4020-011
54”
pilot 1/2” Pipe
Temp. Range
Webb#
11/64”
186656
15/64”
75110
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
155
8 Gas heating
The 1720 Series Replacement Magnet Kit is used with 1710 Series Bodies in TS Automatic Safety Valve applications. All models have FLOW INTERRUPTION so that no gas can flow to the main burner while the reset button is depressed. 1720 Series Kits are designed to replace many individual TS magnet types. Each magnet head kit is tapped for 1/8” pipe with fittings to adapt to 3/16” and 1/4” compression tubing. Also included: spring and diaphragm components, gasket and assembly screws.
SECTION
8
Gas Valves Gas Valves
Pilot, Direct and Hot Surface Ignition 700 Series These 700 Series Gas Valve Uni-Kits® are designed for intermittent pilot, direct spark and hot surface applications. They incorporate a manual valve, pilot valve, and main gas pressure regulator. Each Uni-Kit includes all the necessary parts and instructions needed to convert to direct spark or hot surface applications. OUTLET SIZE (FPT)
straight through
pressure regulator setting
MFR#
Inlet size (FPT)
700-056
3/4”
3/8”
—
3.5” Nat. Gas
350,000
85381
700-059
1”
1”
—
4.0” Nat. Gas
720,000
167052
capacity
Webb#
Universal Models Intermittent Pilot, Direct Spark & Hot Surface
700 Millivolt The 700 millivolt gas valves are wall thermostat actuated combination gas valves. These controls combine a manual gas cock, automatic pilot safety valve and a millivolt operator. The automatic pilot safety is separate from the gas cock and provides gas shutoff in case of pilot outage. Standard features include: pilot outlet, pilot gas filter and pilot adjusting key. Valves can be mounted in any position except upside down. MFR#
700-506
Inlet Straight size Through (FPT) (FPT)
side (FPT) w/ plugs
pressure regulator setting
3/4”
1/2”
capacity
1/2”
3/8”
Webb#
X
X
700-501
1/2”
1/2”
1/2”
None
100,000
—
2
192864
700-502
1/2”
1/2”
1/2”
3.5” W.C. Nat. Gas
100,000
—
2
186752
700-503
1/2”
3/4”
1/2”
None
240,000
1
—
94207
700-505
3/4”
3/4”
Straight-Thru
None
300,000
2
—
73457
700-506
3/4”
3/4”
Straight-Thru 3.5” W.C. Nat. Gas
300,000
2
—
73458
700-507
1/2”
3/4”
Straight-Thru 3.5” W.C. Nat. Gas
240,000
1
—
192865
300,000
2
—
193214
Pool Heater Models 700-511
3/4”
3/4”
Straight-Thru 3.5” W.C. Nat. Gas
700 Snap-Action and Snap-Throttle Hydraulic The 700-200 Series snap-action and snap-throttle (modulating) hydraulic controls are combination gas valves, thermostatically operated by a remote temperature sensing bulb. These controls combine a manual valve (gas cock), an automatic pilot safety valve, pressure regulator (optional by model) and a snap-acting or snap-throttle hydraulic operator for total temperature control. All models feature 3-position main gas outlets and pilot outlet, pilot gas filter, pilot adjustment key and automatic pilot valve.
700-201
MFR#
internal Inlet 3 Position pressure size outlet capillary regulator (FPT) (FPT) length setting
capacity
Reducer bushings included (NPT) 1/2” X 3/8”
Webb#
100,000
2
73454
Snap Action Models 700-201
1/2”
1/2”
36”
None
700-204
1/2”
1/2”
36”
None
160,000
2
73455
36”
3.5” W.C. Nat. Gas
100,000
2
85383
Snap Throttle Models
700-205
156
1/2”
1/2”
Gas Equipment Catalog
victormfg.com
SECTION
8
Gas Valves Gas Valves (continued)
700 24 Volt Combination Valve These valves feature a manual valve (gas cock), an automatic pilot safety valve, inlet/outlet screens, pilot outlet, pilot gas filter and pilot adjustment key. The automatic pilot safety valve is separate from the gas cock and provides gas shutoff in case of pilot outage. Valves can be mounted in any position except upside down.
MFR#
700-406
700-400 700-401 700-402 700-406 700-426 700-438 700-442
3 position outlet Inlet straight side (FPT) Pressure size thru with regulator (FPT) (FPT) plugs setting Snap Action Models 1/2” 3/4” Straight-Thru Uni-Kit 1/2” 3/4” 1/2” None 1/2” 3/4” 1/2” Uni-Kit 3/4” 3/4” 3/4” 3/4” Straight-Thru 3.5” W.C. 1” 1” Nat. Gas 1” 1”
capacity
Reducer bushings included (NPT) 3/4” X 1/2”
Webb#
240,000 240,000 240,000 300,000 300,000 720,000 720,000
1 1 1 2 2 — —
186748 79496 192862 73456 204405 — 103214
700 Diaphragm/Solenoid Valves These controls are single function, diaphragm types and are excellent replacements for solenoid gas valves. Standard features include: pilot outlet, pilot gas filter and pilot adjustment key. Valves can be mounted in any position except upside down.
MFR#
3 position outlet Inlet straight side (FPT) size thru with (FPT) (FPT) plugs
Pressure regulator setting
capacity
Reducer bushings included (NPT) 3/4” X 1/2”
Webb#
2 1 2
118694 204528 167053
24 Volt Diaphragm Models – Have No Safety Magnet 700-417 700-422 700-424
1/2”
3/4”
1/2”
3/4”
3/4”
3/4”
Straight-Thru 1/2” Straight-Thru
None 3.5” W.C. Nat. Gas
300,000 240,000 300,000
700 Line Voltage
capacity
Reducer bushings included (NPT) 3/4” X 1/2”
Webb#
240,000
1
186750
300,000
2
75115
3 position outlet MFR#
Inlet straight size thru (FPT) (FPT)
700-451
1/2”
3/4”
700-454
3/4”
3/4”
side (FPT) Pressure with regulator plugs setting 120 Volt Models 1/2” None 3.5” W.C. Straight-Thru Nat. Gas
705 Millivolt Operators The 705 Series millivolt operator kit is designed to allow field conversion of 700 & 710 Series manual gas valves to wall thermostat control. These operators are also replacements for specific 700-500 Series gas valves. MFR# 4020-010
block color 48”
pressure sensitive setting None
Webb# 192867
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
157
8 Gas heating
These controls combine into one compact valve: a manual gas cock, automatic pilot safety valve and a silent line voltage operator. The automatic pilot valve is separate from the gas cock and provides gas shutoff in case of pilot outage. Valves can be mounted in any position except upside down.
SECTION
8
Gas Valves Gas Valves (continued)
710 Low Profile Gas Heating Valves The 710 low capacity gas heating valves are designed for recreational vehicles and other applications with limited space. All models include a manual valve (gas cock), automatic pilot safety valve, pilot outlet, pilot gas filter and pilot adjusting key. The control can be mounted in any position except upside down and all models have 3-position outlets. MFR#
710-203
710-201 710-203 710-205 710-402 710-501
Inlet reducer pressure size 3 position bushings cap. regulator (FPT) outlet incl. (fpt) length setting Application Hydraulic Models — Snap Action 18” Recreational None Vehicles 1/2” 1/2” (2) 1/2” X 3/8” 36” 3.5” W.C. Wall Furnaces Nat. Gas Replaces TV-27 24 Volt Models 3.5” W.C. Wall Furnaces 1/2” 1/2” (2) 1/2” X 3/8” N/A Nat. Gas 12 VDC, 24 VAC Millivolt Models Note: Use two lead thermopliles only. Space Heaters 1/2” 1/2” (2) 1/2” X 3/8” N/A None Replaced B-67
Webb# 73459 85422 186764 186765 94208
720 Series Hot Surface Gas Valves The 720 Electronic Ignition Gas Valves are designed for a wide variety of heating applications. The valves incorporate a manual valve, dual automatic valves and a main gas regulator. Controls are multiposition and can be mounted in any position (except upside down). MFR#
720-079
720-051 720-079
side outlet pressure 1/2” fpt with regulator plugs setting capacity Standard Model 1/2” 3/4” Uni Kit 150,000 • Universal Model — Intermittent Pilot — Direct Spark — Hot Surface 1/2” 3/4” — Uni Kit 150,000
InleT size (FPT)
outlet size
Webb# 75113 90878
720 Series Dual Valve Gas Controls The 720 Series Dual Valve Gas Controls are designed for a wide variety of heating applications and can be used to replace most constant pilot valves, including dual valve (six function) models. The 720 Series constant pilot gas valve is a six function valve incorporating the manual valve, safety shutoff magnet, dual automatic valves (hence the term dual valves”), main gas regulator, and pilot adjustment. 720-406
MFR# 720-400 720-401 720-402 720-403 720-406 720-474
158
Inlet size (FPT) 1/2” 1/2” 1/2”
SIDE OUTLET pressure REDUCER BUSHINGS STRAIGHT 1/2” FPT regulator THRU WITH PLUGS setting CAPACITY 3/4” X 1/2” 1/2” X 3/8” • — Uni IG 1 — • • None 150,000 1 — • • 1 — 3/4” • • — 1 — Uni IG • — 150,000 2 — Standing Pilot Models — Stop Opening with Convertible Pressure Regulator 1/2” • • • 150,000 — 1
OUTlet size (FPT)
Gas Equipment Catalog
Webb# 167056 73460 167057 186770 73461 186771
victormfg.com
SECTION
8
Gas Valves Commercial Gas Thermostats 4200 (FD) Body Type #2 and Body Type #3 MFR# 4200-005
InleT INLET/ size OUTLET (FPT) SIZE #2 1/2” Pipe
PILOT Side
CAPILLARY MOUNTING LENGTH POSITION 48” 4-Way
BULB SIZE
3/16” X 143/4” Nickel
Webb# 186685
4200 (FD) Body Type #1
4200
MFR#
BODY TYPE
4200-025 Uni-IGI
#2
4200-026 Uni-IGI
#2
INLET INLET OUTLET OUTLET SIDE REAR SIDE SIDE PILOT CAPILLARY MOUNTING “f” “H” “E” “G” OUTLET LENGTH POSITION 150° to 550° F (Degrees) 3/8” 3/8” 3/8” 3/8” Side & 54” 4-Way Pipe Pipe Pipe Pipe Rear Low (200° F) to 550° F (Degrees) 3/8” Pipe
3/8” Pipe
3/8” Pipe
3/8” Pipe
Side & Rear
Kits
54”
4-Way
BULB SIZE
Webb#
3/16” Nickel
—
3/16” x 143/4”
186688
Nickel
®
712 Series Intermittent Pilot Ignition Uni-Kits
The Uni-Line 712 series pilot ignition system features flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. The 712 series pilot ignition system features quick and easy installation with complete in-depth instructions and trouble shooting information.
Uni-Kit
MFR# 712-016
GAS IGNITION VALVE UNIT DESCRIPTION Nonlockout Models — Caution: Do not use on LP. Gas Applications 700-055 780-715 Natural Gas Only — Nonlockout Pressure regulator is 3/4” X 3/4” (Nonlockout) factory-set at 3.5” W.C. 350,000 Btu Max
Webb# 189792
Cycle-Pilot ® Retrofit Kit
Packages Available MFR# 21D18-3
GAS VALVES 38C84-426
FLAME SENSOR 3098-134
ELECTRODE ASSEMBLY 760-56
PILOT RELIGHT 5059-23
WIRING HARNESS F115-0084
Specifications MFR# 21D18-3
COIL VOLTAGE 60 Hz 24 VAC
ELECTRICAL RATING 0.61 amps
INLET/ OUTLET SIZE 3/4” X 3/4”
CAPACITY A.G.A. STANDARD GAS 280,000
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
GAS TYPE Natural Only
Webb# 188186
159
8 Gas heating
21D18-3
Control system designed to eliminate standing pilots by converting to cycle–pilot controls with automatic spark ignition. Gas valve functions are terminated on a printed circuit board that exits through the mercury flame sensor receptacle housing, on the terminal panel side. Features • Eliminates gas wasted by a standing pilot. • Eliminates pilot outage problems due to occasional drafts. • Each package contains the controls and hardware needed for conversion to cycling pilot operation. • Uses existing pilot burner and wiring.
SECTION
8
Gas Valves SmartValve™ System SV9501
Combines gas flow control and electronic intermittent pilot sequencing functions into a single unit. • Suitable for a wide range of gas-fired appliances including residential furnaces, roof-top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and commercial cooking units • Replaces SV9500, SV9501 and SV9502 control. See installation instructions for specific models. Ignition sequence includes timed trial for ignition. SV9501
MFR# SV9501M2528 SV9502H2522 SV9602P4816
TEMPERATURE size RATINGS 1/2” -40° F To 175° F 1/2” -40° F To 175° F 3/4” -40° F To 175° F
Accessories Q3400A1024 39369
PRESSURE REGULATOR SETTING 3.5” W.C. 3.2” W.C. 3.5” W.C.
PrePurge None 15 Sec. 30 Sec.
OPENING CHARACTERISTICS Standard Opening Slow Opening Step Opening
Ignitors Natural to LP Conversion Kit
Webb# 210277 214000 424578
154343 184601
Gas Valves,Electronic Single Stage — Standing Pilot V800 Low Voltage Combination Gas Controls
Provide complete control of continuous pilot gas-fired central furnaces and boilers. • Include pilot flow adjustment screw. • Complete safety shutoff on pilot flame failure. • LITE-RITE (OFF-PILOT-ON) lighting sequence.
V800
MFR# V800A1070 V800A1088
TYPE OF GAS
PRESSURE REGULATOR SETTING
Natural Or LP
3.5” W.C.
INLET/ OUTLET SIZE 3/4” X 3/4” 1/2” X 3/4”
INCLUDES One 3/4” X 1/2” Reducer Bushings/Adapters Two 3/4” X 1/2”, One 1/2” X 3/8” Reducer Bushings/Adapters
Webb# 35054 35055
VR8200 Continuous Pilot Dual Automatic Valve Combination Gas Controls
VR8200
MFR# VR8200A2132
160
TYPE OF GAS Natural
Combination gas controls for use in 24 VAC gas-fired, standing pilot appliances with capacities from 20 to 200 cfh. • Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment. • Compact size. • Provide two automatic valves. • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. LITE-RITE (OFF-PILOT-ON) lighting sequence. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure. • Compatible with ECO connector. PRESSURE REGULATOR SETTING 3.5” W.C.
INLET/OUTLET SIZE 1/2” X 1/2”
Gas Equipment Catalog
OPENING CHARACTERISTICS Standard
INCLUDES
Webb#
1/2” X 3/8” Reducer Bushings; 38389014 bag assembly - 3/4” straight flange with O ring screws and wrench; and 393891 Natural to LP Gas Conversion Kit
68950
victormfg.com
SECTION
8
Gas Valves Gas Valves, Electronic Single Stage — Standing Pilot
VR8300 Continuous Pilot Dual Automatic Valve Combination Gas Control
VR8300
Combination gas control for use in 24 VAC gas-fired standing pilot appliances with capacities from 30 to 300 cfh. • Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment. • Compact size. • Provide two automatic valves. • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure. • Compatible with ECO connector. • LITE-RITE (OFF-PILOT-ON) lighting sequence. MFR# VR8300A4516
PRESSURE INLET/ REGULATOR OUTLET SETTING SIZE 3.5” w.c.
3/4” X 3/4”
INCLUDES Two 3/4” X 1/2” Reducer Bushings; 383200EOO adapter, Q340 (36”) thermocouple with adapters, 393691 Natural to LP Gas Conversion Kit
Webb# 86743
Gas Valves, Electronic Single Stage — Intermittent Pilot
VR8204 Intermittent Pilot Dual Automatic Valve Combination Gas Controls
VR8204 MFR# VR8204A2076
PRESSURE INLET/ OPENING TEMPERATURE REGULATOR OUTLET CHARACTERRATINGS SETTING SIZE ISTICS -18° F to +79° F
3.5” w.c.
1/2” X 1/2”
Standard
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
INCLUDES
Webb#
Bushing 393691 Natural to LP Gas Conversion Kit
76221
3/4” X 3/8” Reducer
161
8 Gas heating
Combination gas control for use in 24 VAC gas-fired intermitent pilot appliances with capacities from 20 to 200 cfh. • Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment. • Use with S86F,H; S8600F,H and S8610 Control Modules. • Compact size. • Provide two automatic valves. • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends. Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted. • Meet codes requiring dual safety shutoff. • Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available. • All adjustments, wiring connections and pilot outlet are accessible from top of control. • ON-OFF lighting sequence.
SECTION
8
Gas Valves Gas Valves, Electronic Single Stage— Direct Ignition VR8345 Universal Electronic Ignition Combination Gas Control
VR8345
Universal electronic ignition combination gas control for use with direct spark ignition, hot surface ignition or intermittent pilot ignition in 24 VAC, gas-fired appliances, with capacities from 30 to 415 cfh. • Control includes manual valve, two automatic operators, pressure regular, pilot adjustment, pilot plug and ignition adapter. • Replaces virtually any IP, HSI, or DSI gas control. • For use with natural or manufactured gas or LP gas. Includes converter kit to adapt from natural to LP gas. • Compact size. • All adjustments and wiring connections accessible from top of control. • Four-inch swing radius allows easy rotation into position inside the tightest furnace vestibules. • Clearly marked, keyed terminal block allows quick attachment of wires and IP/DSI/ HSI jumper. • Internal inlet screen blocks contaminants in gas line from entering valve.
MFR#
INLET/ OUTLET SIZE
PRESSURE REGULATOR SETTING
TYPE OF GAS
VR8345M4302
3/4” X 3/4”
3.5” w.c.
Natural
INCLUDES Two 3/4” X 1/2” NPT Reducer Bushings and one 1/2” X 3/4” NPT Bushing
Webb# 93587
Gas Valves, Millivolt
VS830 Millivoltage Combination Gas Controls
VS830
Provide complete control of continuous pilot gas-fired central furnaces and boilers. • Include pilot flow adjustment screw. • Easy to install, adjust and service; all adjustments and connections are accessible from top of control. • Add separate energy cutoff (ECO) where codes call for dual safety shutoff. • Complete safety shutoff on pilot flame failure. • LITE-RITE (OFF-PILOT-ON) lighting sequence. • ECO connector for V800 models. Part No. 392451-1. MFR#
162
INLET/OUTLET SIZE
VR820A1047
1/2” X 3/4”
VR820A1054
3/4” X 3/4”
Gas Equipment Catalog
PRESSURE REGULATOR SETTING
TYPE OF GAS
3.5” w.c.
Natural
Webb# 35056 35057
victormfg.com
SECTION
8
Thermocouple & Thermopile Generators
Thermocouples and Pilots 1950 & 1951 Thermopiles
The 1950 and 1951 Thermopiles (pilot generators) are designed for use on self-positioned gas control systems.
Mfr# 1950-001 1950-002 1950-003 1950-532 1950-548 1951-001 1951-536
Includes PG9 Connection Length Pilot Adapter Webb# Type 36” 48” 60” 36” 48” 36” 36”
• • • — — • —
Two Lead
Coaxial
82642 194065 186640 192848 186641 73469 111602
1970 Uni-Couples 20 to 30 Millivolts The 1970 Series Uni-Couples unique design allows for installation to virtually all pilot burners. The versatile zip nut may be pushed, pulled or threaded onto the thermocouple’s rolled threads for proper positioning in every application. The stainless steel tip (longer life), extended cold junction (greater voltage output potential), copper tube (corrosion protection with low electrical resistance), and lock washer equipped coaxial connection (resists loosening due to vibration or changes in ambient temperature) make the Uni-Couple the single most versatile thermocouple available today. LENGTH 18” 24” 30” 36” 48” 60” 72”
webb# 167188 167189 167190 85375 155170 186644 85441
1980 Snap-Fit Thermocouples The 1980 Series Snap-Fit Thermocouples offer easy installation into the majority of pilot burners. Both slim and standard thermocouple types are available in the 1980 Series without complicated adapters, but with the extra insulation from high ambient temperatures that the brass sheath offers when needed. The 1980 is constructed of the same materials as used in the 1970. mfr# 1980-018 1980-024 1980-030 1980-036 1980-048 1980-060 1980-072
LENGTH 18” 24” 30” 36” 48” 60” 72”
The 1960-027 is a special low-mass or quick dropout thermocouple. It is usually found on applications that require an oxygen depletion system on the thermo safety. Also found on many L.P. gas applications that require a quick dropout of the thermo safety if there is a loss of pilot flame. Note: Has standard thermocouple threads. Will not fit applications with metric threads. mfr# 1960-027
LENGTH 27”
webb# 217093
Replacement Parts Thermocouple Test Adapter
Adapter to test thermocouple and thermopile closed circuit. mfr# Description 10-238 Thermocouple Test Adapter
webb# 167043
Shank Extension Increases length of 11/4” and 13/8” shank models to approximately 3”. mfr# Description 10-250 Shank Extension
webb# 80696
Junction Block Adapter The 1922-001 adapter allows the high limit switch to be connected into the thermocouple cicuit on valves without the slotted magnet. mfr# Description 1922-001 Junction Box Adapter Y99AN-1H Junction Block Adapter
webb# 75109 178174
1922-001
webb# 73470 73471 186645 73472 152596 73473 188181
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
8 Gas heating
mfr# 1970-018 1970-024 1970-030 1970-036 1970-048 1970-060 1970-072
1960-027 Low Mass Thermocouple
Y99AN-1H
163
SECTION
8
Thermocouples & Thermopile Generators
K15 Series
The K15 Series Thermocouples are designed for use in standing pilot ignition systems. They are used primarily with BASO brand automatic pilot controls and pilot burners. K15DS models are standard thermocouples. K15FS models are snap-on thermocouples that allow for fast, easy assembly. The K15WS model is a wholesale thermocouple that is supplied with additional fittings. Mfr# K15DS-18H K15DS-24H K15DS-30H K15DS-36H K15FS-24H K15FS-36H K15WS-48H
Length(IN) 18 24 30 36 24 36 48
TYPE Standard BASO
Snap in BASO Standard BASO With Fittings
Webb# 184577 183556 183557 184579 183561 183562 183563
“Husky” High Performance Thermocouple K16 Series
The K16 Series are heavy-duty, high performance thermocouples that provide high output for residential, commercial, and industrial applications. The “Husky” is a replacement for BASO 17D, 50, 58D, 87D, 88D, 97D, 107D, and K15DA thermocouples. The K16 is packed with adapters to allow the necessary replacement. K16BT models are standard thermocouples. K16RA models are nickel plated thermocouples. K16WT models are wholesale thermocouples that are supplied with additional fittings. Mfr# K16BT-18H K16BT-24H K16BT-30H K16BT-36H K16RA-60C K16WT-48H
164
“Super Slim Jim™” Universal Replacement Thermocouples
Standard BASO® Thermocouple
Length (IN) 18 24 30 36 60 48
TYPE “Husky”
“Husky” Nickel Plated “Husky” With Fittings
Webb# 183564 152511 183565 96960 194088 183568
Gas Equipment Catalog
Mfr#
Length (IN)
K19AT-18H K19AT-24H K19AT-30H K19AT-36H K19AT-48H K19AT-60H
TYPE
18 24 30 36 48 60
Webb#
“Super Slim Jim”
183569 183570 183571 152513 155142 183574
Replacement Thermopile Generators Q313
Provide power for millivoltage, self-powered control systems. • Eliminate the need for outside power source. • Easy push-in installation. • Include spade terminals. • Individually skin packed, each unit ordered represents one thermopile generator. Mfr#
Lead Length Resistance
includes 1/2” thermopile
Webb#
attaching nut
188174
Q313A1139
Push-in clip
83335
Q313A1170
PG9 adapter (part #393948)
85874
Q313A1188
1/2” thermopile
Q313A1055
47”
2.90 ohm
35”
2.89 ohm
Q313B1005
Push-in clip,
attaching nut Includes junction box for series hook up with high limit switch
84659 86741
Universal 30 mV Thermocouple Q340
There is a Q340 for every gas-fired heating system application. • Replace almost any 30 mV thermocouple. • Average operating life of ten years. • Available in a variety of lead lengths. Mfr# Q340A1066 Q340A1074 Q340A1082 Q340A1090 Q340A1108
Length (IN) Webb# 18” 24” 30” 36” 48”
30876 30877 30878 30879 86216
victormfg.com
SECTION
8
Pilot Burner & Orifices
Anderson & Forrester Inc.
Gauging Drill Kit — GDK4080 Plastic box contains 41 drill sizes: #40 – 80, and GB3020H tapered broach. MFR# Description Webb# ANFGDK4080 Gauging Drill Kit 188739
Tapered Broach — GB3015 Gauging Drill Kit Tapered Broach
Three cornered broach. Tapered from .003” to .013”. A must for cleaning Pilot Orifices. MFR# Description Webb# ANFGB3015 Three Cornered Broach 180504
Gauging Reamer Kit — GRK5000 Have the correct size reamer when you need it. Our kit contains each size in a slim plastic case.
Gauging Reamer Kit
MFR# Description Webb# ANFGRK5000 Gauging Reamer Kit 180593 ANFGR5070 Gauging Reamer, #70, 5 Pack 180602 ANFGR5080 Gauging Reamer, #80 180598
Master Adapter Kit — MIK100 Includes all tools needed to assemble MI100 adapters.
Master Adapter Kit
MFR# Description Webb# ANFMIK100 Master Adapter Kit 180533 ANFMI100 Universal Adapter 180532
Serviceman’s Orifice Assortment Kit — MIK131LP The MIK131 orifice cabinet contains 23 of those orifices most commonly used. Over 300 orifices in proportion to normal demand. MFR# Description Webb# ANFMIK131LP Orifice Assortment 188738
8
Master Pilot Orifice Assortment Kit — MIK132LP In one kit you now have 32 of the most needed pilot orifices with over 100 pieces. These are replacement pilot orifices for Penn Baso, Robertshaw, General Controls, Honeywell and White-Rodgers. A must for every efficient serviceman. Cabinet is made of heavy gauge steel with durable baked enamel finish and radius bottom sections for easy removal. MFR# Description Webb# ANFMI132LP Pilot Orifice Assortment Kit 180534 Master Orifice Kit
Serviceman’s Friend — TL051 For use with flow meter and other applications. One end of fitting has 1/8” pipe thread, 1/4” pipe thread and special 5/16” X 32 thread. Opposite end has regular hose fitting, also 1/8” straight pipe thread. Hose can be used on either end. Serviceman’s Friend
MFR# Description Webb# ANFTL051 Serviceman’s Friend 180578
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
165
Gas heating
Serviceman’s Orifice Kit
SECTION
8
Pilot Burner & Orifices
Replacement Parts & Accessories
Gas Orifices & Gauging Drills (continued)
Pilot Tube Compression Fittings
Just bend and cut to length! Keep a few on your truck to take care of clogged pilots! 3/16” pilot tube, 17” long with 4 port orifice hood.
Break-away type separates upon tightening.
Mfr# 10-383 MFR# Description Webb# 1/8” Short Breakaway Nut 180414 ANFCF639 3/16” Short Breakaway Nut 180415 ANFCF640 1/4” Short Breakaway Nut 180388 ANFCF641 102371 HON386449-1 1/4” Breakaway Nut 1/4” Medium Breakaway Nut 180599 ANFCF642 181653 EMPR1633-2 1/8” Long Breakaway Nut 223431 HON386449-4 1/4” Long Breakaway Nut 1/4” Long Breakaway Nut EMPR2972 EMPR1633-4-2 1/4” X 1/8” Long Breakaway Nut
RBS4590-065 RBS4590-067 RBS4590-069 RBS4590-071 RBS4590-072
1/8” Short Breakaway Nut
3/16” Short Breakaway Nut 1/4” Short Breakaway Nut 3/8” Short Breakaway Nut
7/16” Short Breakaway Nut
181654 181653 93031 93030 93028 186719 189070
Orifice Caps mfr# Description ANFCO400-72 LP, 1/2” Hex, 3/8-40 UNS ANFCO401 Blank, 1/2” Hex, 1/2-27 NPT ANFCO403 Bored, 1/2” Hex, 3/8-27 UNS ANFCO404 Blank, 9/16” Hex, 1/2-27 UNS ANFCO406 Blank, 1/2” Hex, 3/8-27 UNS
webb# 180416 180419 180421 180422 180424
Anderson & Forrester Inc. Orifice Hex Plugs
mfr# Description webb# 180541 ANFPO505 Blank, 1/2” Hex, 1/8-27 NPT 180544 ANFPO508 Blank, 1/4” Hex, 1/4-28 UNF 180546 ANFPO511 Blank, 1/2” Hex, 7/16-27 UNS ANFPO518 Blank, 3/8” Round, 11/32-32 Special 180549
166
Gas Equipment Catalog
description 3/16” X 17” Pilot Tube
webb# 189026
Aluminum Tubing A full range of diameter sizes in 50’ lengths, and for convenience, 5’ lengths with fittings. Mfr# O.D. Size
Length webb#
11-016
7/16”
5’
94204
11-017
3/8”
5’
155172
11-191
1/8”
50’
153380
11-193
1/4”
50’
155171
11-195
3/8”
50’
155173
11-291
1/8”
5’
212789
11-292
3/16”
5’
73442
11-293
1/4”
5’
73443
Pilot Orifices mfr# Gas Type tube size orifice size webb# 1/4” or 3/16” .010 186598 10-030 LP 1/4” .0088 186605 10-261 LP Pilot gas mfr# usage type
tube orifice size size webb#
10-066 #70 & #71 10-043 #70 & #71 10-045 #40A
3/16”
Nat. Nat. & L.P. L.P.
10-028
3/16” 3/16”
.018 .014 .013
— 85387 186600
10-261
10-043 10-045 10-066
victormfg.com
SECTION
8
Pilot Burner & Orifices Pilot Burner Q314
Nonprimary-aerated, insert orifice type pilot burner for main burner ignition with Q340 or Q390 Thermocouple for Pilotstat safety control operation. • Use with Q313 Thermopile Generator for 750 mV powerpile applications. Mfr#
Q314
Q314A4586 Q314A6094 Q314A4585
TYPE OF GAS
MOUNTING BRACKET
DIRECTION OF FRONT TIP
Webb#
B
Front Left Right
80635 86742 —
LP; Natural
Q327 Primary-aerated, spud orifice-type pilot burner for main burner ignition with Q340 or Q390 Thermocouple for Pilotstat safety control operation. • Use with Q313 Thermopile Generator for 750 mV powerpile applications. MFR# Q327A1626
Q347
Description
Type of gas
Webb#
Bat Wing
LP; Natural
88371
Q345 Nonprimary-aerated, combination pilot burner and ignitor. Used with the S86, S8610, or S8670 in intermittent pilot systems. • Includes pilot burner with bracket, ceramic-insulated Kanthal flame rod/spark ignitor and ground strap. Mfr#
Direction of front tip
Q345A1305 Q345A1313
TYPE OF GAS Webb#
Front Left
152195 152196
Natural
Q345A
Combination Type Pilot Burner The J991MDA-2 through J999MDA-2 models are universal replacement pilot burners for J10(-)DDA, J11(-)DDA (D10and D11) types. The pilot burners are individually packaged in a plastic bag. 10 bags per carton. Mfr# J992MDA-2H J997MDA-2H J998MDA-2H J999MDA-2H
2 7 8 9
LP GAS ORIFICE
Webb#
Y90AA-4213 Y90AA-4211 Y90AA-4212 Y90AA-4212
183617 118696 118697 183554
Y90AA-3223 Y90AA-3221 Y90AA-3223 Y90AA-3223
Multi-Mount Universal Pilot Burner #8
J999MHA-2
#9
J999MKA-2
The J Series BASO universal replacement pilot burners are supplied in three models. Mounting brackets on all four sides of each burner permit adaptation to almost any application. The pilot burners are individually packed in a plastic bag. 10 bags per carton. • Three tapped holes in each bracket for vertical adjustment. • Natural and LP gas orifice supplied. • Nuts and bolts furnished in each package. Mfr#
J999MYA-2
J999MHA-2H J999MKA-2H J999MYA-211
TYPE OF PILOT NATURAL GAS ORIFICE LP GAS ORIFICE “L” Channel Shell “Y” Channel
Y90AA-7223 Y90AA-7221 Y90AA-6221
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Y90AA-4211 Y90AA-4210 Y90AA-4211
8 Gas heating
#2
#7
TIP POSITION NATURAL GAS ORIFICE
Webb# — 118699 183620
167
SECTION
8
Pilot Burner & Orifices Pilot Kits
1810-100 Universal 2BLC Pilot Uni-Kit®
1830-700 Pilot Electrode Series
The 1810-100 Universal 2 BLC Pilot Uni-Kit is designed to replace the obsolete Model 2B/2BLC Pilot which is no longer in production. The kit includes fittings for 1/4” tubing and an adapter and fittings to adapt to 3/16” tubing. Each kit comes with a Natural gas orifice installed and includes a separate L.P. gas orifice.
The 1830-700 Series Pilot Uni-Kits are designed for use with the O.E.M. style Pilot Ignition Systems. The electrode is permanently riveted to the pilot frame and the spark gap is fixed at 1/8”. These pilots can be used to replace existing pilot assemblies or when retrofitting standing pilot applications when and exact replacement is desired. Each Uni-Kit comes with a natural gas orifice installed and a separate L.P. gas orifice. Pilot tubing size is 1/4”.
mfr# description 1810-100 Universal Pilot Uni-Kit
MFR# 1890-705
webb# 87067
Flame pattern type Standard
lead length 24”
1820 Series PG9 Replacement Pilot Uni-Kits®
1850/1851 Mini Pilot 100’s
The 1820 Series UniKits are designed to replace those hard-to-find ITT-General PG9 type pilots. Each Uni-Kit come with a natrual gas orifice installed and a separate L.P. gas orifice. A special 1/4” tubing adapter is provided that allows use of original tubing with nut and ball sleeve.
Mini-Pilot 100’s are nonaerated (no primary air) and can be used on all gases with no orifice change. The pilots are positionsensitive and care should be taken to install them in their correct position. (TOP stamped into casting at top when applied).
Flame pattern MFR# (Degrees) 1820-009 90 Right 1820-019
90 Left
1820-029
90 Right
1820-039
90 Left
type of gas Natural and L.P. Gas Orificies Included
MFR#
with thermopile •
Webb# 186617
•
186618
Pilot Only
75116 —
1830 (2CH & 2C) Incinerator-Target Pilot Uni-Kits® The 1930 Series Pilot Uni-Kit is designed to be used with all Uni-Line and competithive thermocouples. Kits include an adaptor that converts a threaded thermocouple/thermopile model 2CH to a snap-in thermocouple type model 2C. Each kit comes with a natural gas orifice installed, and a separate L.P. gas orifice. Hood MFR# type 1830-001 2 1830-002 1830-003 1830-004 1830-005 1830-011
5
mounting bracket type
6
2 4
flame pattern type Standard
Webb# 75118
90 Degrees Left
111048
90 Degrees Right
166784
25 Degrees Left
189032
3-Way (A)
111049
4
3-Way (C)
85399
1830-013
5
7
90 Degrees Left
152595
1830-015
3
4
1830-210
2
1830-213
4
1830-489
6
168
2 6
Standard
186622 75119
3-Way (A)
85434
3-Way (B )
192842
Gas Equipment Catalog
Tube Length
Inlet Size (Tubing)
Horizontal Angle Type #2 Kit 1851-051 24” 1851-052 36” Horizontal Angle Type #4 Kit 1851-152 36” Vertical Bottom Inlet Type #6 Kit 1851-252 24” 1851-253 36”
Webb# —
Webb#
3/16” & 1/4”
192844 192845
3/16” & 1/4”
192847
3/16” & 1/4”
167046 85438
1890-100 (#11) Pilot Uni-Kit® The 1890-100 Pilot Uni-Kit includes fittings for 1/4” tubing and an adapter and fittings to adapt to 3/16” tubing. The kit comes with a Natural gas orifice instlled and includes a separate L.P. gas orifice. mfr# description 1890-100 36” Mini-Pilot, Type #6
webb# 167187
1898 Series Pilots 1898 Series Pilots are used with 4060 (MSA and MSC) Series Safety Valves. Suitable for natural or L.P. gas using the .14 universal orifice. MFR# 1890-022
tubing size 3/16”
tubing size Webb# .14 —
Gas Ignition Controls Replacement Sensors mfr# 10-277
description S1 Sensor has 1/4” quick-connect terminal
webb# 203364
victormfg.com
SECTION
8
Regulators Mercury Flame Sensors The Mercury Flame Sensor is a mechanical device that provides the existence of an acceptable pilot flame. When the bulb is heated by a pilot flame, the mercury is vaporized, causing pressure in the capillary and diaphragm, causing the snap-switch to open one set of contacts, and close a second set. These contacts control the pilot valve and the main valve. MFR# 3098-134 3098-156
element Length
panel type
48”
E
bulb style description Webb# #19 Replaces Bulb Styles #9 or #13. 118711 #20 Replaces Bulb Styles #17 or #18. 205641
3098-134
Gas Valves
1751 Add-On Pressure Regulator Kits The 1751 Series Add-on pressure regulator kits are available for use on the following factory model types; 7000, 7010, 7100, 7200 & 7222. SUITABLE FOR MFR# 1721-003
REGULATOR TYPE 3.5” W.C. Nat. Gas
NAT. GAS —
L.P. GAS —
Webb# 85406
1751-007
Regulator Cover Plate
—
—
192839
1751-003
4080 Pressure Regulators The 4080 Series Pressure Regulators are designed for main burner and pilot duty applications. The regulator is convertible with settings at 4” W.C. Natural gas and 10” W.C. L.P. gas on the 4080-032 and 4080-035.
4080-035
4080-035
pipe size 3/4” X 3/4”
regulator type 4” (Fixed) W.C. Natural Gas 10” (Fixed) W.C. L.P. Gas
suitable for
Webb#
Nat. Gas
73478
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Gas heating
MFR#
8
169
SECTION
8
Hot Surface Ignitors Gas Ignition Controls
41-400 Series Hot Surface Furnace Ignitors
41-401
41-402
41-403
41-404
41-405
Robertshaw’s 41-400 Series Norton Hot Surface Ignitors deliver dependable ignition heating systems of every description. From furnaces and boilers to rooftop heaters, infrared burners, unit heaters, water heaters and many other types of HVAC equipment. The 41-400 Series Hot Surface Ignitors are made of high-purity recrystallized silicon carbide (Crystar™) which combines physical and thermal strength with stable electrical properties. The 41-400 Series are designed to reach ignition temperature(s) within 17 seconds. They have 8-gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity. The lead wires are also enclosed with a special high-temperature fiberglass insulation providing total electrical protection. MFR# 41-401 41-402 41-403 41-404 41-405 41-406 41-407 41-408 41-409 41-410 41-411 41-412 41-413
Factory lead wire Model length Webb# 271A 41/2” 73444 271W 19” 73445 51/2” 73446 271M 41/2” 110330 271D 51/2” 111617 271Y 101/2” 73447 271 111061 271N 153382 271 41/2” 80697 111618 271N 111619 271NM 51/2” 111620 201C 13/8” 189061
41-406
41-407
41-409
41-411
41-408
41-410
41-412
41-600 Series Hot Surface Furnace Mini-Ignitors
41-602
Robertshaw’s 41-600 Series Norton Hot Surface Mini-Ignitors deliver dependable ignition heating systems of every description. All Norton ignitors are engineered for easy handling, simple installation and trouble-free operation. MFR# 41-602 41-604 41-605
41-605
170
Factory Model 601TB 601XBM 601XBM + Harness & Brackets
Gas Equipment Catalog
housing length None 4”
comments Amana #20165702 Armstrong #44744-2
Webb# 250353 241291
2.5”
York Replacement Conversion Kit #473-20937-001
241292
victormfg.com
SECTION
8
Hot Surface Ignitors GlowFly Ignitor The Q3200U Universal Hot Surface Igniter Kit is designed to provide a robust field service replacement igniter in gas fired appliances with Norton/St Gobain 120 VAC silicon carbide hot surface igniters. The Q3200U uses a 120 volt silicon nitride igniter design with long life and high resistance to damage or burn out in the appliance. The kit includes the specially designed silicon nitride igniter and six different bracket configurations to adapt the igniter to the specific appliance application along with accessory parts to allow mounting and wiring the igniter. Clear instructions and application templates are provided to simplify selection of the proper bracket and ease installation of the replacement. MFR# HONQ3200U1004 HONQ3200U2002
DESCRIPTION GLOWFLY UNIV HOT SUR IGNITOR GLOWFLY UNIV HOT SUR IGNITOR (6PC)
Webb# 417300 417299
Hot Surface Ignitor
Igniters Direct are a durable universal direct upgrade for replacing most silicon carbide igniters. MFR# URK24V URK120VF URK120VR
comments 24V Hot Surface Igniter 120V Flat Universal Kit 120V Round Ignitor Kit
Webb# 309804 268458 401572
Ignitors Replaced by URK24V
8
The smart-lite™ igniter flame rod assembly is a direct replacement for all 24 volt hot surface igniter SmartValve™ systems and includes equipment made by AO Smith, Armstrong Furnace, Bradford White, Ducane and Skymark.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Gas heating
Used in SmartValve™ Replaces Igniter Flame systems including: rod assembly including: SV9500 1009524 SV9500M2603 1149856 SV9500M2674 42640001 SV9500M2682 CARQ3400A1024 SV9500M-2682 Q3400A SV9501M2528 Q3400A1016 SV9600 Q3400A1024 SV9600H Q3400A1040 SV9401 Q3450 SV9402 Q3480 SV9403 Q3620 SV9501 SV9502 SV9503 SV9601 SV9602
171
SECTION
8
Hot Surface Ignitors Ignitors Replaced by URK120VG & URK120VR Note: URK120VR may be used as a flame rod sensor. URK120VF may NOT.
Manufacturer American Road Equip Acro Air Armstrong Air Carrier Corporation Claire Brothers Coleman Comfort Maker Detroit Radiant DMO Industries Dornback Furnace Ducane Enerco Tech Evcon Goodman Heil Hupp Industries Intercity Majestic Metzger Mor-Flo Nordyne Norton Raypak Rheem Roberts Gordon Robertshaw Smith HB Snyder General Superior Fireplace Tempstar Trane Company Viessman Wayne Home Equip Weil McLain White LB Company White-Rodgers Williamson York International
172
Part Number 201W 1096048 | 1380680 38322B001 LH33ZS001A | LH33ZS002 C-238 | C-242 1474-051 | 1474-052 1096048 201D 20834 271W 20015201 10399 1474-051 | 1474-052 B10401009 1096048 9050 1009604 | 1096048 75-92-104 | 75-92-105 201N | 201W 3200618 105141000 | 632-0770 | 632-0880 | 902661 | 902694 | 903110 | FC007 201 | 201D | 201K | 201L | 201R | 201W | 271 | 271D | 271M | 271N | 271NM | 271P | 271W 600915 62-22441-01 | 62-22868-82 | 62-22868-93 90434300 | 90436600 41-402 | 41-403 | 41-404 | 41-405 | 41-407 | 41-408 | 41-409 | 41-410 | 41-411 | 41-412 | 41-414 50018 1380654 | 1380672 | 1380680 94851 1096048 | 1148245 340039P01 | B138196P01 | B144676P01 | B144676P02 | B340039P01 | IGN21 | IGN23 | IGN26 | IGN30 9302-094 62821-001 | 62821-002 511-330-139 | 511-330-190 | 511-330-193 120-07549 767A-301 | 767A-303 | 767A-306 | 767A-310 | 767A-311 | 767A-350 | 767A-353 | 767A-354 767A-357 | 767A-361 | 767A-364 | 767A-365 | 767A-366 | F767A-357 | F767A-361 | F767A-365 | F767A-366 9050 025-27766-000 | 025-27774-000 | 025-29043-000 | 025-29050-000 025-32625-000 | 025-32626-000 | 025-33421-000 | 373-05342-700 | 473-12509-001
Gas Equipment Catalog
victormfg.com
SECTION
8
Regulators WAGS Water and Gas Safety Valve The WAGS Water and Gas Safety Valve™. The WAGS valve shuts off the water supply (plus has supply for gas-fired water heaters) when it detects a water leak, preventing disastrous flooding and damage to structures and belongings. WAGS
mfr# WAGS7200
size & Connection Water and Gas Safety Shut-Off Valve for Hot Water Heaters
webb# 243562
FloodMaster, inc. Water Feed
Alarm/Shut-off System Kit • • • • • •
Easy installation. No wiring — just plug in. No maintenance. Audible alarm and interface with your home security system. NSF 61/UL/CE/CSA. Reusable.
mfr# FLOODMASTER
description Alarm/Shut-Off Kit
webb# 242185
Gas Guardian System The Gas Guardian™ Carbon Monoxide & Gas Leak Protection system has taken the original gas leak protection system a step further by adding a carbon monoxide alarm. When the alarm detects carbon monoxide at dangerous levels (as defined by the UL2034 and EN50291 standards) it will cause the gas valve to close, shutting down all gas-appliances and preventing further accumulation of carbon monoxide. This is all done automatically to protect your property, and give you complete peace of mind.
8
Mfr# Description Webb# QMIQGC201RGRS CO/GAS DETECTOR 411881 QMIQGKM511GRS CO/GAS GUARDIAN 411882
Gas heating
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
173
SECTION
9
Pump Accessories Positive Displacement Meters MA™ Series Meters MA-4™/MA-5™
MA-4 Meters in Class 10 construction are designed specfically for LPG motor fuel applications (UL Listed): • Capacity: 30 GPM (115 L/min.) • Choice of 11/2” standard and 2” optional companion flanges. MA-5 Meters in Class 10 construction are designed for LPG truck and high speed LPG motor fuel applications (UL Listed) • Capacity: 60 GPM (225 L/min.) • Choice of 11/2” standard and 2” optional companion flanges. MA-7™
MA-4-CX-10
MA-7 Meters in Class 10 construction are designed for LPG truck and bulk loading applications (UL Listed). • Capacity: 100 GPM (380 L/min.). • Class 12 construction for NH3 (Anhydrous Ammonia) service available upon request. • Choice of 2” NPT standard, 11/2” optional companion flanges. MA-15™
MA-15 Meters in Class 10 construction are designed for LPG bulk delivery truck and bulk loading applications (UL Listed). • Capacity: 200 GPM (760 L/min.) • Standard 3” inlet, 2” outlet with choice of NPT, BSPT or steel welding flange (3” outlet optional). MFR#
Description
MA-4+
MA-7-GY-10
MA-5+ MA-7+
350 PSI 21 BAR 2068 kPa
MA-15+
maximum nominal Flow rate
Standard Flange size
30 GPM (113 L/min.)
11/2” NPT
60 GPM (227 L/min.)
11/2” NPT
100 GPM (380 L/min.)
2” NPT
200 GPM (757 L/min.)
3” NPT
primary material
Webb# —
Aluminum
— — 251204
Model Description Chart – Example shown is meter model MA-15-GY-10
174
Gas Equipment Catalog
victormfg.com
SECTION
9
Pump Accessories Power Rewind Reels with Bottom-Mounted Guidemaster To handle single 1” or 11/2” I.D. hose
Series PBGMB The Hannay Series PBGMB hose reel is designed specifically for open-deck or compartment mounting, especially when recovery is of an angle other than straight off the reel. Rewind: Choose chain and sprocket drive powered by an electric, hydraulic, or compressed air motor. Gear-driven mechanism with pinion shaft brake can be specified as auxiliary crank rewind on power rewind reels, at extra cost. Brakes & Locks: These reels are supplied with a strap brake. Other brake and locking devices may be specified. Inlet: Standard inlet is 90° ball bearing swivel joint with 11/2” female NPT threads. Outlet: Standard outlet is flanged riser with 11/2” female NPT threads. Standard inlet, outlet riser, and hub assembly are steel. Other sizes and/or threads can be furnished and must be specified. Operating Pressures and Temperatures: These reels operate at pressures to 350 psi (24 bar) and handle product temperatures from -40° F to +350° F (-40° C to + 177° C). Reels to operate at other pressures and temperatures can be furnished at extra cost.
Series PBGMB
Hose capacity of reel feet (m) I.D. (in) I.D. (mm)
1” 25.4
11/2” 38.1
o.D. (in) o.D. (mm)
1.5” 38.1
2.16” 54.8
— —
125 45.7
50 15.2
— —
150 45.7
— —
200 61.0
MFR# For Power Rewind See Note 2
Reel Dimensions Inches (mm)
A
B
C
D
E
F Elec.
F. Air
F. Hyd
PBGMB 24-23-24
21 533.4
15.5 393.7
10.5 266.7
20.5 520.7
22.75 577.9
29.25 743.0
28.25 717.6
28.25 717.6
—
75 22.9
PBGMB 30-23-24
27.5 698.5
22 558.8
10.5 266.7
20.5 520.7
22.75 577.9
35.75 908.1
34.75 882.7
34.75 882.7
—
110 33.5
PBGMB 28-25-26
27.5 698.5
22 558.8
10.5 266.7
25.5 647.7
24.75 628.7
33.75 857.3
32.75 831.9
32.75 831.9
—
Webb#
Specifications subject to change.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
175
pumps/compressors
Dimensions and Capacities
9
SECTION
9
Pump Accessories Power Rewind Reels with Bottom-Mounted Guidemaster (continued)
Hose capacity of reel feet (m) I.D. (in) I.D. (mm)
1” 25.4
11/2” 38.1
o.D. (in) o.D. (mm)
1.5” 38.1
2.16” 54.8
MFR#
Approx Weight lb. kg.
Reel Dimensions Inches (mm)
For Power Rewind See Note 2
G
H
J
k
l
net
ship
Webb#
23.5 596.9
12.12 307.8
51 1295.4
39.75 1009.7
33 838.2
160 73
185 84
—
— —
125 45.7
50 15.2
PBGMB 24-23-24
— —
150 45.7
75 22.9
PBGMB 30-23-24
23.5 596.9
12.12 307.8
51 1295.4
43 1092.2
35.25 920.8
170 77
200 91
—
— —
200 61.0
110 33.5
PBGMB 28-25-26
27.88 708.2
15.5 393.7
52 1320.8
42 1066.8
35.25 895.4
173 78
203 92
—
Specifications subject to change.
Notes:
1. Upon request, reels can be supplied with drum lengths other than shown and with disc sizes in other diameters. 2. When ordering power rewind models, prefix model number with: A = Air Rewind – Supplied with control valve and hose. E = Explosion Proof Electric Rewind (1/2 HP) – Supplied with explosion proof switch, solenoid and junction box. HD = Hydraulic Rewind – Not supplied with control valve. 3. Dimension J is maximum, with fully extended Guidemaster in operating position. Dimension K is maximum, with fully extended Guidemaster in traveling position opposite rewind motor, as shown in dimensional drawing. Dimension L is maximum, with fully extended Guidemaster in travelling position on same side as rewind motor. (The telescoping feature of the Guidemaster permits each of these dimensions to be reduced up to 4”.) Maximum distance from frame of reel to outside edge of Guidemaster locked in traveling position is 11”.
Victor/F.w. Webb stocks siemens generators.
176
Gas Equipment Catalog
victormfg.com
SECTION
9
Pump Accessories
Flex Connectors
Flex Hose
mfr# size Webb# 1/2” X 12” 187507 FLES50-12 3/4” X 12” 187508 FLES75-12 FLES100-12 1” X 12” 187500 187501 FLES125-12 11/4” X 12” 187502 FLES125-18 11/4” X 18” 187503 FLES150-12 11/2” X 12” FLES200-14 2” X 14” 187505 FLES300-24 3” X 24” 187506
Other sizes can be custom made.
Style B 112, 600#, Threaded, Ductile Iron SC000B112AD Size
Weight
Webb#
SCSB112AD-34
MFR#
3/4”
21/2 lbs.
184112
SCSB112AD-1
1”
41/2 lbs.
261609
SCSB112AD-114
11/4”
7 lbs.
184114
SCSB112AD-112
11/2”
8 lbs.
184115
2”
15 lbs.
193217
SCSB112AD-2
Style C 103, 600#, Threaded with Bolted Cover, Ductile Iron SC000C103AD Size
Weight
Webb#
—
MFR#
2”
20 lbs.
—
SCB112AD-3
3”
41 lbs.
202666
—
4”
100 lbs.
—
pumps/compressors
Applications: General purpose Stainless Steel double braided metal flexible gas hose assemblies code rated @ 350 psi available with NPT, ASME flanges, and pipe weld ends. For use typically as a vibration dampener/flexible connector 1/2” – 4” sizes on pump, compressor, and generators. Also available UL536 listed Metal Hose Assemblies suited for Natural Flammable and Combustible Liquid and Gas Service @ 175 psi. All flexible connectors pictured have schedule 80 NPT threaded end with a corrugated stainless hose covered with a double braided stainless steel assembly cover.
Self-Cleaning Strainers
Style A 105, 300#, Flanged, Ductile Iron SC000C103AD MFR#
Size Weight Webb#
—
2”
39 lbs.
—
SCSSC0300A105AD
3”
65 lbs.
S497139
SCSSC0400A105AD
4”
130 lbs.
S497138
9
LP Gas Flowmeter Internationally recognized for our superior flowmeter replacement parts, Liqua-Tech now offers the Model LPM-102 LP Gasliquid flowmeter. Designed for retail sales dispensing units, the LPM-102 offers the widest flow range, (3-18 gpm) available in a meter of this type. In addition, the LPM-102 contains all required accessories including vapor eliminator, strainer and differential valve. mfr# LIQLPM102 —
DescRIPTION SIZE Webb# 3/4” 182604 1 Gal. Register — 2” —
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
177
SECTION
9
Pump Accessories Swivel Connectors
Full-Circle offers a complete line of swivel connectors designed for use with thin to viscous liquids and liquefied gases. Straight-through hose end swivels allow the filler valve to rotate 360°. This enables the driver to make tank connections without fighting the hose. It also prevents hose twisting upon reel-up. For bulk-head use, the 90° swivel allows for the use of a shorter transfer hose and enables the operator to safely sweep the hose to one side for proper, out of the way storage. The design is ideally suited for hose reel use as the sealed high load ball bearing can tolerate misalignment problems that could cause product leakage in other swivel types. The tri-directional movement of the three-piece seal package continually compensates SMAC-112LN; 11/2” FNPT 90° Swivel for eccentric movement. Additional Notes The Zero maintenance design is of critical importance, especially for leading/unloading Temperature range: arms that must be constructed high in the air for railroad tankcar transfer operation. -40°F to + 350°F Safety First All swivels produced by Full-Circle for LP-gas, ammonia, and flammable liquids Hydrostatic test pressure: are listed by the Underwriters Laboratories and are designed and tested in accordance with 2000 psi for ammonia swivels, the U.L.-567 standard, your assurance that the product has been tested to a standard of 1750 psi for other liquid/ safety. liquefied gases No Maintenance Design All Full-Circle swivels unitize a sealed high load ball bearing. Maximum working pressure: No greasing or lubrication is ever required. 400 psi for ammonia swivels, 350 No Rotating Rubber Seals All full-circle swivels incorporate the superseal™ mechanical psi for other liquid/liquefied gases seal. This patented design allows the seal ring to “float” between two metallic seals. While Maximum rotatinal speed: in operation, the seal ring rotates at one-half the swivel rotational speed. The tri-directional 1000 RPM movement of the seal components allows for continuous adjustment due to vibration, Maximum load on ball bearing at misalignment, and temperature extremes. Upon depressurization, the seal spring maintains 33 RPM: a constant force on the seal package, preventing product leakage in zero to low pressure 5000 lbs for 11/2” and 2” swivels, environments. 2000 lbs for other SMAC prefix Misalignment Minimized All Full-Circle swivels utilize a radial contact ball bearing swivels, and 1000 lbs for JO prefix swivels with extremely high load ratings. The bearing is sealed for life and requires no periodic lubrication. The ball bearing completely supports the rotating portion of the swivel to U.L. Standard: ensure smooth and easy movement. 567 Field Replacement Components All full-circle swivels are designed so that replacement parts can be installed simply and easily in the field with no special tools required. 90° Type — Same thread size for inlet and outlet MFR#
90° Type
Size
SMAC-3490LN
3/4” X 3/4”
SMAC-190LN
1” X 1”
SMAC-114LN
11/4” X 11/4”
SMAC-112LN
11/2” X 11/2”
SMAC-200LN
2” X 2”
Threads
A
B
Weight
Webb#
3”
45/8”
63/4 lbs.
283972
31/4”
43/4”
131/8 lbs.
309126
Female NPT
Straight Through Type — Same thread size for inlet and outlet MFR#
Straight Through Type
Size
SMAC-34STLN
3/4” X 3/4”
SMAC-1STLN
1” X 1”
SMAC-114STLN
11/4” X 11/4”
SMAC-112STLN
11/2” X 11/2”
SMAC-200STLN
2” X 2”
Threads
A
B
Weight
Webb#
51/4”
31/16”
41/2 lbs.
—
511/16”
47/8”
113/4 lbs.
—
Female NPT
Straight Through Hose-End Filler Valve Type — Allows filler valve to rotate 360° Straight-Through Hose End Filler Valve Type
178
MFR#
Size
Threads
A
B
Weight
Webb#
JO-1LN
1” X 1”
Female X Male
33/8”
21/2”
11/2 lbs.
246584
Gas Equipment Catalog
victormfg.com
SECTION
9
Pump Accessories Krug Compressor mfr# description KRUH50LP Transfer Compressor, LP Engine KRUH50G Transfer Compressor, Gas Engine
webb# 182405 182404
Basic Hose Kit
pumps/compressors
qty mfr# description webb# Liquid Transfer Hose 30’ HOS3/4 3/4” LP Hose 185604 2 HOSHY12-12MP 3/4” Hydraulic Coupling, 2 pieces in kit 185576 Compressor Inlet Hose (Bobtail to Compressor) 12’ HOS1/2 1/2” LP Hose 185581 2 HOS7661-08MP08TY 1/2” Hydraulic Coupling 193208 Compressor Outlet Hose (Compressor to Tank to be Evacuated) 25’ HOS1/2 1/2” LP Hose 185581 2 HOS7661-08MP08TY 1/2” Hydraulic Coupling 193208 Fittings 1 RGO3175 3/4” Hose Coupling 162687 1 F/S34CO3SE 3/4” Hose Coupling, 3M 8735 1 RGO7550P 3/4” Transfer Angle Valve 162760 1 RGO3165CP 1/4” Bleeder Valve* 186852 1 RGO7590U-10 3/4” Check Lock Adapter* 162762 1 RGO3175B 1/2” Hose Coupling 186853 1 RGO3171A 1/2” Vapor Coupling 162686 2 JOM100-703 1/2” Ball Valve 151448 *Install in 7550P for new style Checklok
9
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
179
Pump Station Kits
SECTION
9
Pump Station Without Meter
180
Gas Equipment Catalog
victormfg.com
SECTION
9
Pump Station Kits
Pump Station Without Meter
(continued)
Pump Station Schematic Drawing Key No Meter Drawing
Qty Alpha Code Description Webb#
1
1
1
G/T1000AG
1000 Gal. Above Ground LP Tank
185224
1
G/T500AG-B
500 Gal. Above Ground LP Tank
215818
2 (A,B,C) 1
VCTTANKST
Victor Tank Stands, Pump Mount, and Meter Mount
184438
3
42’
D/P114BPE
11/4” X 21’ sch40 black pipe price per foot. Use 2 full lengths each leg for 1000 gal., cut 2 to 16’ for 500 gal.
4
—
—
Checklok Emergency Liquid Evacuation Valve (Possible Rego 7590U)
45533 —
5
—
—
POL Service/Vapor Evacuation Valve (Possible Rego 7556R12.0)
—
6
—
—
Double Check Filler Valve (Possible Rego 7579)
—
7
1
RGOA8017DP
Bottom Tank Valve Liquid Service 11/4” X 1”
8,9
1
CRKC12SMB
Corken Pump C12SMB 11/2” Pnlet 1” Putlet 1 HP Motor With Switch Mounted On Motor And B166 Bypass 181039
10
1
NIPCS114X1XH
11/4” X 1” Concentric Swedge Nipple XH
11
2
F/S114903SE
11/4” 90 Elbow 3000# Forged Steel Threaded
12
1
NIP114X10XH
11/4” X 10” XH Black Nipple
13
1
SCSB112AD-114 11/4” Ductile Iron Strainer Threaded
14
1
F/S34PL
3/4” Plug 3000# Forged Steel Square Head Threaded
15
1
NIP114X8XH
11/4” X 8” XH Black Nipple
1
FLES125-12
11/4” X 12” Stainless Steel Double Braided Flex Connector With SCH80 Threaded Ends
1
F/S114UN3SE
11/4” Union 3000# Forged Steel Threaded
18
1
F/S112X114BU
11/2” X 11/4” Bushing Forged Steel
19
1
NIPCS1X34XH
1” X 3/4” Concentric Swedge Nipple XH
20
1
F/S34T3SE
3/4” Tee 3000# Forged Steel Threaded
21
4
NIP34X6XH
3/4” X 6” XH Black Nipple
187220 8693 187212 184114 8831 14636 187501 9101 8872 187219 8715 14602 162428
22
1
RGO3127U
Rego 1/4” Hydrostatic Relief Valve 450#
25
1
F/S14S903SE
1/4” Street 90 Elbow 3000# Forged Steel Threaded
26
1
CRK1449
Corken Gauge Adapter/Pressure Snubber 1/4” M/F
181098
27
1
RGO1224WA
Rego 1/4” Needle Valve
186802
8723
—
28
1
F/S14C03SE
Coupling 3M FS TH 1/4”
29
1
GAUP300
Ashcroft 21/2” Dial 1/4” Bottom Connection 0-300 psi
36489
31
21
D/P34XHBPE
3/4” X 21’ SCH 80 Black Pipe Price Per Foot
45478
30
6
F/S34903SE
3/4” 90 Elbow 3000# Forged Steel Threaded
8691
32
1
RGO7550P
Rego 3/4” Angle Valve M/F
162760
33
1
RGO7590U-10
Rego Check-lok Adapter, Possible Alternate RGO7572-14C For Older Style Check-lok
162762
34
1
F/S34CO3SE
3/4” Coupling 3000# Forged Steel Threaded
35
2
HGR1GUBOLT
1” Galvanized U-Bolt With Nuts
8735 69033
36A
3
HOS3/4
3’ - 3/4” LP Dayco Hose
185604
36B
2
HOSHY12-12MP 3/4” Hydraulic Hose Ends For Dayco Hose
185576 162683
37
1
RGOA2141A6
Rego 3/4” Breakaway/Pullaway Coupling
38
1
F/S34X12BU
3/4” X 1/2” Bushing 3000# Forged Steel
39A
18
HOS1/2
18’ - 1/2” LP Dayco Hose
39B
2
HOS7661-08MP08TY 1/2” Hydraulic Hose Ends For Dayco Hose
40
1
RGO7901TB
Rego 1/2” X 1/4” Snap Acting Hose Valve
162488
41
1
RGO7193D-10
1/4” X MPOL Rego Hose Adapter
186884
not shown
1
RGO7193T-10
FPOL X 15/16 F Acme Adapter Rego FPOL-QCC1 Adapter
162472
not shown
1
FBS1124
Fairbanks 1124 1000# Scale
181957
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
8857 185581 193208
181
pumps/compressors
16 17
162493
9
Pump Station Kits
SECTION
9
Pump Station With Meter
182
Gas Equipment Catalog
victormfg.com
SECTION
9
Pump Station Kits
Pump Station With Meter
(continued)
Pump Station Schematic Drawing Key With Meter Drawing
Qty Alpha Code Description Webb#
1
1
G/T1000AG
Tank LP Above Ground 1000 Gal.
185224
1
1
G/T500AG-B
Tank LP Above Ground Bot./Drn. 500
215818
Nut Short Ref. 3/8” * NS45 E6NUT
2
2
SAE38RNUT
3
1
SAE38X14MUN Union 3/8 X 1/4 FLR X M * U1-6B
4
1
SAE38X14M90
ELL 90 3/8 X 1/4 FLR X M * E1-6B
5
1
PIG1005
POL X 3/8 Male Flare
34571 19780 19834 186522
6
2
SAE58X34MUN Union 5/8 X 3/4 FLR X M * U1-10E
19791
7
2
SAE58RNUT
Nut Short Ref 5/8 * NS410 E10NU
34814
8
1
RGO7550P
Valve Angle Trans. * 3/4
162760
9
1
RGO7590U-10
Adapter Check Lock * 3/4
162762
10
2
RGO3127U
Valve Relief Hydro 450 1/4”
162428
11
1
RGOA8017DP
Valve Multi Purpose 11/4 MN
162493
12
1
NIPCS114X1XH Nipple Conc. Swedge 11/4 X 1 X H
13
1
F/S1903SE
Elbow 90 3M FS TH 1”
1
NIP1X 3XH
Nipple Black X H 1 X 3 STL
1
F/S114903SE
Elbow 90 3M FS TH 11/4”
16
1
NIP114XHPAK
Nipple BLK X H PAK 1 EA 11/4 X CLO
17
1
SCSB112AD-114 STRNR 11/4 DI 600 THD 20” MESH
18
1
F/S1PL
Plug 3M FS SQ HD 1”
19
1
FLES125-12
Hose 11/4 X 12 SS SGL BRD S80MN Union 3M FS TH AAR 11/4”
20
1
F/S114UN3SE
21
1
NIPCS112X114XH Nipple Conc. Swedge 11/2 X 11/4 X H
8692 14612 8693 111655 184114 8832 187501 9101 187221
22
1
CRKC12SMB
Kit Pump 1 HP MTR MNT SW 3/4 BY
181039
23
1
NIPCS1X34XH
Nipple Conc. Swedge 1 X 3/4 X H
187219
24
1
F/S34T3SE
Tee 3M FS TH 3/4”
25
1
NIP34XHPAK
Nipple BLK X H PAK 1 EA 3/4 X CLO
26
1
F/S34UN3SE
Union 3M FS TH AAR 3/4”
27
1
NIP34X24XH
Nipple Black 34 X 24 X H WLD
8715 111669 9099 318897
28
3
F/S34903SE
Elbow 90 3M FS TH 3/4”
8691
29
1
F/S34T3SE
Tee 3M FS TH 3/4”
8715 8857
30
1
F/S34X12BU
Bushing 3M FS HEX 3/4 X 1/2
31
1
RGO3129U
Valve Relief Hydro 450 1/2”
32
1
LIQLPM102
Meter Flow With 1 Gallon Register
182604
33
1
RGO3272G
Valve Excess Flow 3/4”
162584
34
3
HOS3/4
Hose LP 3/4 7132-75354
35
2
HOSHY12-12MP Coupling Hydraulic 3/4
36
1
RGOA214A6
Valve Pull Away 3/4”
37
1
F/S34X12BU
Bushing 3M FS Hex 3/4 X 1/2
38
18
HOS1/2
Hose LP 1/2 7132-50354
39
2
HOS7661-08MP08TY Coupling Hydraulic 1/2
40
1
RGO7901TB
Valve Quick Act 1/4 FN X 1/2 FN
162488
41
1
RGO7193D-10
Connector Fill With Soft Nose
186884
42
1
RGO7193T-10
Adapter Fill FPOL X 15/16 AC
43
1
RGO07193L-10A Connector Fill
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
162432
185604 185576 162683 8857 185581 193208
162472 162471
183
pumps/compressors
14 15
187220
9
SECTION
9
Pump Station Kits Pump Station With Meter
(continued)
Pump Station Schematic Drawing Key With Meter Drawing
Qty Alpha Code Description Webb#
44
1
RGO5760A
Adapter FP X 1/4 FN
162457
45
1
SHR901H
FPOL X 13/4 Acme S
184119
46
1
CRK1449
Adapter Pressure Gauge
181098
47
1
F/S14S903SE
Elbow 90 3M FS TH ST 1/4”
48
1
RGO1224WA
Valve Needle Brass 1/4
49
1
F/S14CO3SE
Coupling 3M FS TH 1/4”
8723 186802 8732 110920
50
1
ASH00516
Gauge 63 3005PHL 02L 300
51
42
D/P2BPE
Pipe S40 BLK PE 2 X FT
52
8
HGR12GWASHER Washer Flat PLT 1/2 130 PG
53
4
HGR12GNUT
54
4
HGR12X2GBOLT Bolt HEX HD GAL 1/2 X 2 41 PG
55
1
VCTTANKST
Stands Tank With Pump
184438
56
1
FBS1124
Scale Portable Beam
181957
57
1
MIL48-89-1565
Bit Twist Drill 1/4
74665
58
1
MIL48-89-1645
Bit Twist Drill 1/2
247642
59
—
—
15 Feet 1/4 K Soft Copper
362953
60
—
—
10 Feet 1/2 K Soft Copper
360279
Nut HEX HD PLT 1/2” 110 HPG
45504 69051 69046 34458
Victor/F.w. Webb stocks york furnaces.
184
Gas Equipment Catalog
victormfg.com
SECTION
9
Pumps/Compressors Coro-Flo® Turbine Pumps Stationary Applications
C-Model With Close Coupled Motor
Designed specifically for LPG The Corken Coro-Flo® pump was designed for LPG, NH3 and other light liquids. For lowcapacity, medium-head pumping, the Coro-Flo pump is the pump of choice. Extremely quiet and free of vibration and pulsation, the Coro-Flo pump provides trouble-free service and long life for volatile liquids such as LPG. The exclusive turbine construction provides smooth continuous flow through the pump case, resulting in higher efficiency and greater capacity and pressure for the same size motor. The one moving part, the impeller, floats on the shaft without contacting adjacent surfaces, thus extending pump life. Simple to Service The Coro-Flo® pump has been designed for simplicity of inspection and service. The cover can be removed and the impeller and seal serviced without disturbing the piping. The balanced mechanical seal is furnished with its own sleeve, providing extremely reliable service. The Coro-Flo pump is listed by Underwriters’ Laboratories, Inc. for use in LP-Gas and anhydrous ammonia service. mfr# description Dispensing Station Pumps CRKC10S 3/4 HP, 115/230V Remote
webb# 181031
CRKC10SB
3/4 HP, Remote Switch, Bypass
181032
CRKC10SM
3/4 HP, 115/230V Switch
181033
CRKC10SMB
3/4 HP, SW Mount & Bypass
181034
CRKC12
1 HP Motor
181035
CRKC12S
1 HP 115/208/230 Remote
181036
CRKC12SB
1 HP Motor, Remote Switch
181037
CRKC12SM
1 HP 115/208/230 Switch
181038
CRKC12SMB
1 HP Kit, SW Mount 3/4 Bypass
181039
CRKC13
2 HP Motor
212890
CRKC14
3 HP Motor, SW Mount
204939
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
pumps/compressors
SPECIFICATIONS MODEL 10 12 13 14 Inlet 11/4” NPT 11/2” NPT 11/2” NPT 11/2” NPT Outlet 1” NPT 1” NPT 1” NPT 1” NPT RPM-60 Hz 3450 3450 3450 3450 Max. Differential Press. 50 Hz PSI (Bar) 60 (4.1) 75 (5.2) 75 (5.2) 75 (5.2) 60 Hz PSI (Bar) 70 (4.8) 100 (6.9) 125 (8.6) 125 (8.6) Mounting Options Close Coupled Yes Yes Yes Yes Direct Driven (101) Yes Yes Yes Yes V-Belt (103) Yes Yes Yes Yes Direct Mounted Frame (DS/DL) Yes Yes Yes Yes Double Seal Option (Except C-Model) Yes Yes Yes Yes Flange Option 11/2” X 1” — 300# Yes Yes Yes Yes (Except C-Model) Impeller Material Opt. Bronze (Standard), Ductile Iron, Stainless Steel O-Ring Material Opt. Teflon(r), Viton(r), Buna-N (Standard), Neoprene(r), Teflon(r), Ethylene-Propylene Viton(r), Ethylene-Propylene Seal Seat Material Options Ceramic Ni-Cast Iron, Cast Iron (Standard), Ni-Resist, Stainless Steel, SS304, Tungsten Carbide Tungsten Carbide, Ceramic Temperature -25/225°F -25/225°F -25/225°F -25/225°F (min/max) -32/107°C -32/107°C -32/107°C -32/107°C Maximum Driver 5 HP 10 HP 10 HP 20 HP 3.7 KW 7.5 KW 7.5 KW 15 KW
9
185
SECTION
9
Pumps/Compressors Coro-Flo® Turbine Pumps Stationary Applications (continued) Wire Sizing Chart Motor
—
Motor Phase 1 —
c12
1
1
c13
2
1
c14
3
3
Model c9 c10
HP 3/4
(a) recommended Wire Size, AWG approximate full load amperes 9.0 5.0 16.0 8.0 20.0 10.0 8.0 4.0
volts 115 230 115 230 115 230 230 460
Length of Run in Feet 0-100 12 12 8 12 8 12 12 12
to 200 8 12 6 12 4 10 12 10
to 300 6 12 4 10 2 8 12 8
Pump must rotate in the direction shown on pump case. If not, switch any two of the three incoming 3 phase lines.
115V 115V
208-230V 208-230V
208-230V 208-230V
2277-X12277-X1 OR 2277-X2 SWITCHSWITCH2277-X12277-X1 OR 2277-X2 SWITCHSWITCH OR 2277-X2 OR 2277-X2 T3
T3
T1
T1T1
T2
T1 L1
T1
L1 LINE
T2 LINE
T4
T4 T2
T2
L2
L2
LINE
T1 T1
T2 LINE
T1
L1
LINE
4
4 7
7 1
LINE 1
LINE 4
4 7
7 1
LINE 1
LINE
5
5 8
8 2
LINE 2
LINE 5
5 8
8 2
LINE 2
LINE
6
6 9
9 3
LINE 3
LINE 6
6 9
9 3
LINE 3
LINE
L1
T2
T3 LINE T4
460V 460V
T3 LINE
T4
T2
T2
L2
LINE
L2
FOR MODELS C9, C10, FOR MODELS C9,C12 C10,AND C12C13 AND C13
FOR MODELS C14 ONLY FOR MODELS C14 ONLY
Victor/F.w. Webb stocks electrical test equipment. See our tools section in this catalog.
186
Gas Equipment Catalog
victormfg.com
SECTION
9
Pumps/Compressors Coro-Flo® Pumps Autogas Pumps Corken Autogas Pump achieves new levels of performance with higher flows at high differential pressures, non-pulsating and quiet transfer, longer pump life and a design that is easy to repair. The pump is also versatile enough to be used in like applications such as cylinder filling, vaporizer feeding, or bulk transfer. mfr# description
FF150CD6A
webb#
Dispensing Station/Aerosol/Refrigerant Pumps CRKF10CD Pump f/10
181043
CRKF12CD
Bare Coro-Flo
181044
CRKF14CD
Bare Coro-Flo
181045
CRKDL14
Direct Mount, Large Frame
181211
CRKDS12CDC
Direct Mount, Small Frame
181216
FF150CD6A
Autogas Pump
369968
F-Model The F-Model pump is the base plate mounted version. Coro-Flo® pumps are design to operate at shaft speeds between 2880—3600 rpm. The F-Model provides the flexibility of motor selection. F-Model 101 Direct Drive
Autogas Pumps — Operating Specifications Models
DS/DL-Model Direct Mounted
Specifications Inlet Outlet RPM—50 Hz RPM—60 Hz Maximum Working Pressure Maximum Differential Pressure 50 Hz 60 Hz Mounting Options Direct Driven (101) V-Belt (103) Direct Mounted Frame Impeller Material Options O-Ring Material Options Seal Seat Material Options Temperature (Min/Max)
1 Neoprene®, Viton® and PTFE® are registered trademarks of the DuPont Company.
Maximum Driver Type of Electric Motor
FF150
dlf150
11/2” ANSI 300# R.F. Flange 1” ANSI 300# R.F. Flange 2,880 3,450 28.5 bar (400 psi)
11/2” ANSI 300# R.F. Flange 1” ANSI 300# R.F. Flange 2,880 3,450 28.5 bar (400 psi)
200 psi (13.8 bar) 200 psi (13.8 bar) 250 psi (17.2 bar) 250 psi (17.2 bar) — — Yes No Yes No No Yes Bronze (Standard), Ductile Iron, Stainless Steel Buna-N (Standard), Neoprene®1, PTFE®1, Viton®1, Ethylene-Propylene Cast Iron (Standard), Ni-Resist, Stainless Steel, Tungsten Carbide, Ceramic (-25) 225ºF (-25) 225ºF (-32) 107ºC (-32) 107ºC 20 hp 20 hp 15kW 15kW Rigid-Base C-Face
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
187
pumps/compressors
DS/DL Model The DS/DL Model pumps are designed to eliminate the need for a baseplate, coupling guard, and coupling alignment which makes the DS/DL series pumps compact and easy to install. The special bracket supports both the pump and the motor so they can be directly coupled.
9
SECTION
9
Pumps/Compressors Coro-Flo速 Pumps
(continued)
Autogas Capacity Chart 17.5
250
17.5 Curves based on L/min Capacity Power Required
15.0
15.0
20.0
200 12.5 15.0 10.0
10.0
7.5
7.5
5.0
5.0
bar
150
hp
100
kw
Differential Pressure psi
12.5
10.0 7.5
5.0
50 2.5
2.5 3.0
0
0
0
50
100
150
200
250
0
0
L/min. 0
10
20
30
40
50
60
gpm Capacity
Victor/F.w. Webb stocks the laars mascot gas boiler. it provides both heat and domestic hot water!
188
Gas Equipment Catalog
victormfg.com
SECTION
9
Pumps/Compressors Coro-Vane® Pumps Corken Coro-Vane® pumps are positive displacement pumps. They produce a maximum differential pressure of 125 psig (8.6 bar g). Corken manufactures four sizes of Coro-Vane pumps, ranging from 1gpm to 350 gpm (0.2–79.5 m3/hr). Corken offers these pumps with v-belt or direct-drive mounting options.
Z-Series Z3500 Stationary and Truck Pump The new three-inch Z3500 LPG pump is designed for stationary and foot mounted truck applications. The Z3500 stationary pump has the same locked rotor design used in the Corken Z-Series truck pumps to ensure long pump life and excellent performance. With higher flow rates than other three-inch pumps, the Z3500 retrofits Corken’s and other competitive pumps with little or no change in piping.
1021ef103
Bulk Filling, Carousel Filling & Cylinder Filling mfr#
webb#
Stationary Plant Pumps CRK521EF* Stationary Coro-Vane
181022
CRK521EG103*
Coro-Vane Pump With Mount
181023
CRK1021EF*
Bare Coro-Vane Pump
181013
CRK1021EF103*
Coro-Vane Pump With Mount 284T
181042
Z3500
Coro-Vane Z-Pump
401115
Z3500-103
Pump With Mount
401116
pumps/compressors
521 Cutaway
Description
*Soon to be obsolete.
M3/hr 10
20
30
40
50
60
80
950 860
RPM
640
100 PSID (6.90 Bar)
521
1021
1521
420 950 860 640
9
40 PSID (2.76 Bar)
521
1021
1521
420 100
150
200
250
300
GPM
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
189
SECTION
9
Pumps/Compressors Coro-Vane® Truck Pumps
The Z-Series Coro-Vane® truck pumps are specifically designed to perform in such severe operating conditions as high differential pressure, pump overspeeding, poor suction conditions and heavy thrust loads associated with a power take-off (PTO) drive system. mfr#
Description
webb#
Coro-Vane Pump Trucks CRKZ3200 Pump Truck
181234
CRKZ4200
204940
4” Transport
Specifications
Z3200
specifications models Z3200 Z4200 Suction Flange 3” 4” 300# ANSI 300# ANSI Discharge Flange 2” 2” NPT EI Dual NPT Maximum RPM 800 Minimum -25°F Temperature (-32°C) Maximum 225°F Temperature (107°C) Maximum 400 PSIG Working Pressure (28.6 Bar) Maximum 125 PSID Differential Pressure (8.6 Bar) Discharge Flange Open Yes No Internal Relief Valve Yes Yes Steel Slip-On Flange Option Yes Yes
Z4200
Z3200 Performance Chart Pump Speed rpm 800 800 650 650 500 500
190
Differential pressure psi 50 100 50 100 50 100
bar — 6.9 3.4 6.9 3.4 6.9
approximate delivery on propane gpm 121 110 98 88 73 63
Gas Equipment Catalog
lpm 460 420 371 333 276 238
brake hp required bhp 6.6 10.6 5.2 8.2 3.8 5.8
KW 4.9 7.9 3.9 6.1 2.8 4.3
pump torque required ft. lbs. 43.4 69.3 42.0 66.3 39.9 60.9
kg/m 6.0 9.6 5.8 9.2 5.5 8.4
victormfg.com
SECTION
9
Pumps/Compressors Compressor The “107” bulk plant gas compressor unit is complete with pressure gauges, steel baseplate, mechanical liquid trap, four-way valve, strainer, interconnecting piping, adjustable driverslide-base, v-belt drive and beltguard ready to receive an electric motor. This standard unit is typically used for liquid transfer and vapor recovery in applications including rail car and truck loading and unloading. Many options such as ASME liquid traps with Class1, Group D switches and total engineered packages can be provided.
Model 107
mfr# description Gas Transfer Compressors CRK91-107A (see table below) CRK291-107 (see table below) CRK491-107 (see table below) CRK691-107 (see table below)
webb# 181024 — — —
pumps/compressors
SPECIFICATIONS MODEL 91 291 491 691 891 Bore of Cylinder Inches (MM) 3.0 (76.2) 3.0 (76.2) 4.0 (101.6) 4.5 (114.3) 4.5 (113) Stroke Inches (MM) 2.5 (63.5) 2.5 (63.5) 3.0 (76.2) 4.0 (101.6) 4.0 (101.6) Piston Displacement CFM (m3/HR) Minimum @ 400 RPM 4.0 (6.8) 8.0 (13.6) 17.2 (29.2) 29.2 (49.6) 56.6 (96.2) 76.8 (130.5) Maximum @ 825 RPM 8.3 (14.1) 16.5 (28.0) 35.5 (60.3) 60.2 (102.3) 113.2 (192.0) Maximum @ 1200 RPM — — — — — Max. Working Pressure 350 (24.1) 350 (24.1) 350 (24.1) 350 (24.1) 465 (32.1) Max. Brake Horesepower (KW) 7.5 (5.6) 15 (11) 15 (11) 35 (26.1) 45 (34) Maximum Rod Load LP (KG) 3600 (1632.9) 3600 (1632.9) 4000 (1814.4) 5500 (3175.2) 7000 (3175.2) Max. Outlet Temp. °F (°C) — — — 350 (177) — Bare Unit Weight LB (KG) 115 (52.2) 160 (72.6) 260 (117.9) 625 (283.5) 855 (387.8) Maximum Flow-Propane 50 (11.4) 101 (22.9) 215 (48.8) 36 (82.0) 694 (157.6) GPM (m3/HR) ANSI/DIN Flange Option F91 F291 F491 F691 —
9 Victor/F.w. Webb stocks rinnai continuum water heaters. we can also help you size your job!
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
191
SECTION
9
Pumps/Compressors Compressor Selection Appendix C—Compressor Selection Propane Propane Compressor Selection Table Compressor Selection Table
Service Small bulk plants
Unloading single tank car or transport
Unloading two or more tank cars at one time or large transport with excess flow valves of adequate capacity
Unloading large tank cars, multiple vessels, barges or terminals
Capacity Displacement Compressor gpm1 cfm Model RPM 23 4 91 400 29 5 91 505 34 6 91 590 40 7 91 695 39 7 290, 291 345 45 8 91 795 44 8 290, 291 390 50 9 290, 291 435 56 10 290, 291 490 61 11 290, 291 535 66 12 290, 291 580 71 13 290, 291 625 79 14 290, 291 695 84 15 290, 291 735 84 15 490, 491 345 89 16 290, 291 780 89 16 490, 491 370 95 17 490, 491 390 101 18 490, 491 415 106 19 490, 491 435 108 20 490, 491 445 114 21 490, 491 470 119 22 490, 491 490 125 23 490, 491 515 130 24 490, 491 535 136 25 490, 491 560 141 26 490, 491 580 147 27 490, 491 605 152 28 490, 491 625 158 29 490, 491 650 163 30 490, 491 670 163 30 690, 691 400 168 31 490, 491 695 171 31 690, 691 420 179 32 490, 491 740 178 32 690, 691 440 186 34 690, 691 455 193 35 690, 691 475 200 36 690, 691 495 208 38 690, 691 510 215 39 690, 691 530 223 41 690, 691 550 230 42 690, 691 565 237 43 690, 691 585 245 45 690, 691 605 252 46 690, 691 620 260 47 690, 691 640 275 48 690, 691 675 297 54 690, 691 730 319 58 690, 691 785 334 60 690, 691 820 452 82 D891 580 623 113 D891 800
Driver Horsepower Liquid Liquid Transfer Transfer & Without Residual Residual Driver Sheave Size Vapor Vapor Pitch Diameter (inches)2 Recovery Recovery 1,750 RPM 1,450 RPM 100°F 80°F 100°F 80°F A 3.0 A 3.6 5 3 3 3 A 3.8 B 4.6 5 5 5 5 B 4.6 B 5.6 5 5 5 5 B 5.4 B 6.6 5 5 5 5 A 3.0 A 3.6 3 3 3 3 B 6.2 B 7.4 7-1/2 7-1/2 7-1/2 7-1/2 A 3.4 B 4.0 5 3 3 3 A 3.8 B 4.6 5 5 3 3 B 4.4 B 5.2 5 5 5 5 B 4.8 B 5.8 5 5 5 5 B 5.2 B 6.2 7-1/2 5 5 5 B 5.6 B 6.6 7-1/2 5 7-1/2 5 B 6.2 B 7.4 7-1/2 7-1/2 7-1/2 7-1/2 B 6.6 B 8.0 10 7-1/2 10 7-1/2 A 3.0 A 3.6 7-1/2 7-1/2 5 5 B 7.0 B 8.6 10 10 10 10 A 3.2 A 3.8 7-1/2 7-1/2 7-1/2 5 A 3.4 B 4.0 7-1/2 7-1/2 7-1/2 7-1/2 A 3.6 B 4.4 10 7-1/2 7-1/2 7-1/2 A 3.8 B 4.6 10 7-1/2 7-1/2 7-1/2 B 4.0 B 4.8 10 7-1/2 7-1/2 7-1/2 B 4.2 B 5.0 10 7-1/2 7-1/2 7-1/2 B 4.4 B 5.2 10 10 7-1/2 7-1/2 B 4.6 B 5.6 10 10 10 7-1/2 B 4.8 B 5.8 15 10 10 10 B 5.0 B 6.0 15 10 10 10 B 5.2 B 6.2 15 10 10 10 B 5.4 B 6.4 15 10 15 10 B 5.6 B 6.6 15 15 15 15 B 5.8 B 7.0 15 15 15 15 B 6.0 15 15 15 15 B 4.4 B 5.2 15 15 10 10 B 6.2 B 7.4 15 15 15 15 B 4.6 B 5.6 15 15 10 10 B 6.6 B 8.0 15 15 15 15 B 4.8 B 5.8 15 15 10 10 B 5.0 B 6.0 15 15 15 10 B 5.2 B 6.2 15 15 15 10 B 5.4 B 6.4 15 15 15 15 B 5.6 B 6.8 20 15 15 15 B 5.8 B 7.0 20 15 15 15 B 6.0 A 7.0 20 15 15 15 B 6.2 B 7.4 20 15 15 15 B 6.4 A 7.4 20 15 15 15 B 6.6 B 8.0 20 15 15 15 B 6.8 20 20 15 15 B 7.0 A 8.2 20 20 20 15 B 7.4 B 8.6 25 20 20 20 B 8.0 B 9.4 25 20 20 20 B 8.6 25 20 25 20 TB 9.0 A 10.6 30 25 25 20 5V 7.1 5V 8.5 30 30 30 30 5V 9.75 5V 11.8 40 40 30
Piping Size3 Vapor Liquid 3/4 1-1/4 3/4 1-1/4 1 1-1/4 1 1-1/2 1 1-1/2 1 1-1/2 1 1-1/2 1 1-1/2 1 2 1 2 1 2 1-1/4 2 1-1/4 2 1-1/4 2-1/2 1-1/4 2-1/2 1-1/4 2-1/2 1-1/4 2-1/2 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/4 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 3 1-1/2 4 1-1/2 4 1-1/2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 3 6 3 6
1
The capacities shown are based on 70°F, but will vary depending upon piping, fittings used, product being transferred and temperature. The factory can supply a detailed computer analysis if required. 2 Driver sheaves: 91 (2 belts); 290, 291, 490, 491 (3 belts); 690, 691 (4 belts). 3 The piping sizes shown are considered minimum. If the length exceeds 100 ft., use the next larger size. NOTE: Please consult factory for compressors with higher flows.
192
Gas Equipment Catalog
36
victormfg.com
SECTION
9
Bypass Valves Bypass Valves ZV200 Bypass Valve The two-inch ZV200 is a low pressure build-up bypass valve designed for applications requiring protection for positive displacement pumps. Specifically designed for protecting pumps with capacities up to 250 gpm (946 L/min). The continuous internal bleed will assist in the operation of systems with “air” or “electric” operated internal valves. Typical applications include bobtail, transport and stationary loading and unloading of LPG, NH3 and other light liquids. Applications Used for both truck and stationary applications for loading and unloading.
ZV200
Features and Benefits • Dimensionally interchangeable with commonly used two-inch bypass valves; no need to change piping configuration. • Ductile iron construction offers maximum strength for higher pressures. • Flow rates up to 250 gpm (946 L/min) at 120 psi (8.3 bar) differential. • Continuous bleed helps equalize pressure to assist remote operated internal valves. • Multiple spring options enable you to select the pressure required for your truck or stationary application.
Bypass Valves—Specifications for B166, T166, B177 and ZV200 pumps/compressors
Models Specifications
B166B
T166
B177
ZV200
Inlet
3/4”, 1”
11/4”, 11/2”
2”, 21/2”
2”
Outlet
3/4”, 1”
11/4”, 11/2”
2”, 21/2”
2”
No
No
2”, 21/2”
No
22 – 225 psi
22 – 225 psi
10 – 125 psi
91 – 125 psi
Slip-On Flange Option Differential Pressure Range
Buna-N (Standard), Neoprene 1, PTFE 1, Viton 1, Ethylene-Propylene*
O-Ring Material Options
®
®
®
* Ethylene-Proplyene not available for B177, 1 PTFE , Vitron and Neoprene® are registered trademarks of the DuPont Company. ®
MFR#
®
Description
WEBB#
B166B75B
3/4” Coro-Flo /Autogas
181026
B166B1B
1” Coro-Flo®/Autogas
181025
B177125B
11/4” Coro-Vane®
181027
B177150
11/2” Coro-Vane®
181028
B1772B
2” Coro-Vane®
181029
11/4” Truck Pump
181049
T166–1.25
®
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
9
193
SECTION
9
Bypass Valves Bypass Valves
(continued)
B166 (3/4” and 1”) Automatic Dual Purpose, Bypass Valves The B166B is a combination bypass and priming valve specifically designed for small cylinder filling type pumps, especially of the regenerative turbine type, such as the Coro-Flo pump series. The patented vapor elimination system keeps liquefied gas pumps primed to increase system reliability and decrease pump and seal wear. The B166B is a smooth operating bypass with moderate pressure buildup. Applications Used with all cylinder filling pumps. (Coro-Flo Models and low flow side channel pumps).
B166
T166 (11/4” and 11/2”) Pump Flow Control Valve The T166 valve provides smooth-acting flow control. Specifically designed for bypass protection for pumps in the 30–100 GPM (6.8–22.7 m3/hr) range, such as those used on delivery trucks. In contrast to the B177, the T166 valve opens gradually as pressure builds up to modulate the flow, bypassing the excess capacity smoothly and silently back to the supply tank. A continuous internal bleed in this valve assists in eliminating vapors. Applications Used with large capacity pumps filling various sizes of tanks and bottles such as those used with delivery trucks or multi-spot cylinder-filling plants.
B177 (2” and 21/2”) Differential Bypass Valve The B177 is a low-pressure buildup valve specifically designed for applications requiring protection for positive displacement pumps in the 50–350 GPM (11.4–79.5 m3/hr) for smooth-acting flow control. To properly function, this valve requires a pressure sensing line for the storage tank. This valve should be applied where horsepower is limited and accuracy set points and flow points are necessary. Applications Used in liquefied-gas bulk plant installations for the loading and unloading pumps. B177
194
Gas Equipment Catalog
victormfg.com
SECTION
9
Electric Motors Explosion Proof TEFC (IP54) UL and CSA Approved The WEG line of World Energy Guardian TM Motors are specifically designed to meet or exceed ALL APACT requirements for energy efficiency.
Standard Features: • 3 phase, 60 Hz, 208-230/460,460 or 575 V. • 143T up to 586/7 cast iron frame. • Squirrel cage rotor/Aluminum die cast. • Enclosure TEFS (IP54). • All motors supplied with ball bearings except roller bearings in drive end for frames 404T and up, in IV, VI, and VII pole. • Class “F” insulation. • Temperature rise: Class “B” (80°C). • Service factor: 1.15 (see electrical data for exceptions). • Dimensions according to NEMA standard. • NEMA ratings design “B” (except 900RPM Design “A”). • Continuous duty (S1). • 104°F (40°C) ambient temperature.
pumps/compressors
mFR# description webb# MTR00218XP3E245T HP 2 XProof 3 Phase 1800 RPM Motor 318199 206666 MTR00718XP3E213T Motor 71/2 HP 1800 RPM 3PH 208V MTR0108XP3E215T 10 HP 1800 RPM 3PH XProof Motor 183302 MTR01518XP3E254T #15 HP 3 Phase 1800 RPM X PR 254T FR — MTR02018XP3E256T #20 HP 3 Phase 1800 RPM EXP. Proof — MTR02518XP3E284T #25 HP 3 Phase 208V RPM 284T M —
9 Nema Frames 14 3T 14 5T 18 2T 18 4T 21 3T 21 5T 25 4T 25 6T
Mounting 2E 5.500 7.750 8.500 10.000
2f 4.000 5.000
h 0.344
4.500 5.500 5.500
10.000
A
2.250
6.457
2.750
8.661
3.500
9.764
0.406
7.000 8.252
ba
0.531
4.250
12.126
B
c
5.157
12.760
6.142
13.752
5.945
14.862
6.969
15.862
7.402
17.952
8.898
19.450
10.000
23.175
11.732
24.929
D
G
J
k
o
p
t
3.500
0.429
1.496
1.654
7.000
7.000
—
4.500
0.787
1.890
1.969
9.421
8.909
5.250
0.827
2.008
2.185
11.156
10.709
6.250
0.817
2.520
2.559
12.352
12.224
1.772
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
2.087
195
SECTION
9
Electric Motors Explosion Proof TEFC (IP54)
Nema Frames 14 3T 14 5T 18 2T 18 4T 21 3T 21 5T 25 4T 25 6T
keyway width
depth
key length
0.187
0.093
1.375
(continued)
Shaft Extension
bearings
n-w
u
ab
2.250
0.875
6.811
aa
d1
DE
od.e
6205-ZZ
6204-ZZ
6307-ZZ
6206-ZZ
NPT 3/4” 0.250
0.125
1.750
2.750
1.125
8.240 A4
0.313
0.156
2.375
3.375
1.375
9.252
NPT 1”
6308-ZZ
6207-ZZ
0.375
0.187
2.875
4.000
1.625
11.063
NPT 11/2”
6309-C3
6209-ZOC3
Victor/F.w. Webb stocks rinnai space heaters. we can also help you correctly size them with a building heat loss!
196
Gas Equipment Catalog
victormfg.com
SECTION
9
Repair Parts
Parts Details for Models C9 to C14
O-Ring Code
1
2
3 4
5
6
Buna-N
B
Neoprene ® 1
E
Teflon ® 1
MFR# 7001-031NC100A 1001-09 1001-0 1001-2 1001-3 1001-4 1001-5 10142 1014-12 2-246 2-247E2 1003-096 1003-06 1003-26 1003-36 1003-46 1003-56 113-CX_3 113-CXA 113-CXB 113-CXD 113-CXE 1004-1X 2, 3
1004-11X 7
1004-2X 1004-21X 1013
8
1013-1
Description
Qty Webb#
Ref#
MFR#
Description
9
2-224_3
Housing O-Ring
1
10
3442
Pipe Plug, 1/4” NPT
1
—
11
3444
Pipe Plug, 3/4” NPT
1
—
12
1002-09 1002-0 1002-2 1002-3 1002-4 1002-5
Case—Model 9 Case—Model 10 Case—Model 12 Case—Model 13 Case—Model 14 Case—Model 15
1 1 1 1 1 1
— — — — — —
1914-1 7012006SF019E 7002037NC087A 1015
Nameplate
1
—
Phillips Head Screw 6 – 32X1/4”
2
—
Socket Head Cap Screw
8
—
Adapter Ring
1
—
Woodruff Key, Steel Woodruff Key, SS Motor 3/4 HP Models 9, 10 Motor 1 HP Model 12 Motor 3 HP Models 14, 15 Motor 3/4 HP, Obsolete Models 9E, 10 Motor 11/2 HP, Obselete Model 12E Motor 2 HP Model 13
1 1 1 1 1 1
— — 181167 181168 — —
1
—
1
—
Hex Head Cap Screw
8
—
Cover—Model 9 Cover—Model 10 Cover—Model 12 Cover—Model 13 Cover—Model 14 Cover—Model 15 Case Clearance Shim (.002” Red) Case Clearance Shim (.003” Green) Case O-Ring (Non-Teflon®1) Case O-Ring Teflon®1 Impeller, Brass—Model 9 Impeller, Brass—Model 10 Impeller, Brass—Model 12 Impeller, Brass—Model 13 Impeller, Brass—Model 14 Impeller, Brass—Model 15 Seal Assembly Seal Assembly Seal Assembly Seal Assembly Seal Assembly Seal Housing, Steel (Non-Teflon®1 O-Rings) Seal Housing, SS (Non-Teflon®1 O-Rings) Seal Housing, Steel (Non-Teflon®1 O-Rings) Seal Housing, SS (Non-Teflon®1 O-Rings) Housing Adjustment Shim (0.010”) Housing Adjustment Shim (0.020”)
1 1 1 1 1 1 As Req. As Req. 1 1 1 1 1 1 1 1 1 1 1 1 1 1
— — — — — — 181071 —
13
— — — 181060 181062 181063 181064 — — 181075 181076 181077 181057 310362
14
1
—
1
—
1
—
As Req. As Req.
181069 —
15 16 17
18
2497 2497-1 2555 2556 25575 28955 28965 4261
1
3 4 5 6 2
4
Qty Webb# —
Registered trademarks of the DuPont Company. Included with seal assembly/repair kit 113-CX_. _Denotes O-Ring Code. Prior to S.N. PR166727 motor part number was 3760. Starting with S.N. PW168290 will be new motor frame size. Add a 1 to # for iron or a 2 for stainless steel (example: model 10 with iron is 1003-01).
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
197
pumps/compressors
Ref#
A
9
SECTION
9
Repair Parts Parts Details for Models F9C to F15C, FF9 to FF15C and F109 to F115
O-Ring Code
Ref# 1
2
3 4
5
6
A
Buna-N
B
Neoprene ® 1
D
Vitron ® 1
E
Teflon ® 1
G
Ethylene Propylene ® 1
K
Kalrez ® 1
MFR# 7001031NC100A 1001-09 1001-0 1001-2 1001-3 1001-4 1001-5 10142 1014-12 2-246 2, 3 2-247E2 1003-094 1003-04 1003-24 1003-34 1003-44 1003-54 113-CX_3 113-CXA 113-CXB 113-CXD 113-CXE 1004-1X 1004-11X
7
1004-2X 1004-21X 1013
8 9 10 11
198
1013-1 2-224_3 3442 3444
Description
Qty Webb#
Ref#
MFR#
Description
12
1002-09 1002-0 1002-2 1002-3 1002-4 1002-5 4206-09 4206-0 4206-2 4206-3 4206-4 4206-5
Case—Model 9 Case—Model 10 Case—Model 12 Case—Model 13 Case—Model 14 Case—Model 15 Case—ANSI Flanged Model 9 Case—ANSI Flanged Model 10 Case—ANSI Flanged Model 12 Case—ANSI Flanged Model 13 Case—ANSI Flanged Model 14 Case—ANSI Flanged Model 15
Qty Webb# 1 1 1 1 1 1 1 1 1 1 1 1
— — — — — — — — — — — —
1914-1 Nameplate 7012Phillips Head Screw 6 – 32X1/4” 006SF019E 5002-281 Bearing Retainer Ring
1
—
2
—
1
—
Hex Head Cap Screw
8
—
Cover—Model 9 Cover—Model 10 Cover—Model 12 Cover—Model 13 Cover—Model 14 Cover—Model 15 Case Clearance Shim (.002 Red) Case Clearance Shim (.003 Green) Case O-Ring (Non-Teflon®1) Case O-Ring Teflon®1 Impeller—Model 9 Impeller—Model 10 Impeller—Model 12 Impeller—Model 13 Impeller—Model 14 Impeller—Model 15 Seal Assembly Seal Assembly Seal Assembly Seal Assembly Seal Assembly Seal Housing, Steel (Non-Teflon®1 O-Rings) Seal Housing, SS (Non-Teflon®1 O-Rings) Seal Housing, Steel (Non-Teflon®1 O-Rings) Seal Housing, SS (Non-Teflon®1 O-Rings) Housing Adjustment Shim (0.010) Housing Adjustment Shim (0.020) O-Ring (Housing) Pipe Plug, 1/4” Pipe Plug, 3/4”
1 1 1 1 1 1 As Req. As Req. 1 1 1 1 1 1 1 1 1 1 1 1 1 1
— — — — — — 181071
— — — 181060 181062 181063 181064 — — 181075 181076 181077 181057 310362
1
—
23
3226
Key
1
—
1
—
24
2759
Ball Bearing
1
181177
1
—
25
Frame
1
—
As Req. As Req. 1 1 1
181069
Socket Head Screw
4
—
27
1010-2 7002037NC087A 2158
Grease Zerk
2
—
28
2159
Lubricap
2
—
— 13 14 15
Gas Equipment Catalog
1238
Bearing Cap
1
—
17
1006
Grease Seal
1
181067
18
5102-118
Bearing Retainer Ring
1
—
19
2758
Ball Bearing
1
181176
20
5000-281 24972 2497-12 1234 1234-1
Bearing Retainer Ring #5 Woodruff Key, Steel #5 Woodruff Key, SS Shaft Shaft, Stainless Steel
1 1 1 1 1
—
21 22
26
— — — —
16
1
3 4 5 6 2
— 181091 —
Registered trademarks of the DuPont Company. Included with seal assembly/repair kit 113-CX_. _Denotes O-Ring Code. Prior to S.N. PR166727 motor part number was 3760. Starting with S.N. PW168290 will be new motor frame size. Add a 1 to # for iron or a 2 for stainless steel (example: model 10 with iron is 1003-01).
victormfg.com
SECTION
9
Repair Parts
Parts Details For Stationary Coro-Vane® Pumps Models 521 and 1021
pumps/compressors
9
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
199
SECTION
9
Repair Parts Parts Details For Stationary Coro-Vane® Pumps Models 521 and 1021 (continued) Ref#
MFR#
Description
1162-2 1201-2 2832 2841 1172-2.53 1172-23 1206-34 2-234_2, a 2-245_2 2-249_2
Cam (521) Cam (1021) Case (521) Case (1021) 2.5” Flange (521) 2” Flange (521) 3” Flange (1021) Flange O-Ring (521) Flange O-Ring 3” (1021) Flange O-Ring 4” (1021)
1 1 1 1 1 1 2 2 2 2
181078 181086 — — — — — 181148 — —
5
2-112_2
Adjusting Screw O-Ring
1
—
6
2590
Flush Seal Plug 1/8” NPT
1
—
7
2252
Relief Valve Adjusting Screw
1
—
1 1 1 1 1 1 1 1 1 1 1 1 10 10 1 1
— — — — — — — — — — — — — 181094 — 181089
1 2 3 4
8 9 10 11 12 13 14 15
1174 Valve Cap (521) 1207 Valve Cap (1021) 1242-X Relief Valve Spring & Guide (521) 1227 Relief Valve Spring Guide (1021) Relief Valve Cap O-Ring (521) 2-224_2 2-228_2 Relief Valve Cap O-Ring (1021) 1241 Relief Valve (521) 1224 Relief Valve (1021) 1242 Relief Valve Spring (521) 1226 Relief Valve Spring (1021) 1170 Cam Key (521) 1309 Cam Key (1021) 1168-7 Blade (521) 1308-9 Blade (1021) 116-1X1R Rotor & Shaft Assembly (521) 1208-1X1R Rotor & Shaft Assembly (1021)
Qty Webb#
Ref#
MFR#
Description Hex Head Bolt 5/16 – 18X1 – 1/4 (521) Hex Head Bolt 3/8 – 16X1 – 1/4 (1021) Hex Head Bolt 3/8 – 16X1 – 1/4 (521) Hex Head Bolt 3/8 – 16X1 – 1/4 (1021)
37
7001-031 NC125A 7001-037 NC125A 7001-037 NC125A 7001-037 NC125A 7001-037 NC150A ———5
38
———5
39
2-227_2
40 41
34
35 36
42
4
—
4
—
28
—
32
—
Hex Head Bolt 3/8 – 16X1 – 1/2
8
—
Retainer
2
—
Seal Seat
2
—
Seal Seat O-Ring
2
—
2159
Lubricant #2
2
—
1359 7003-004 DR0198
Lubricant Instruction Tag Round Head Plated Drive Screw 4X3/16
2
—
2
—
Seal assemblies are available in two forms: a. Complete seal kit including bearing housing, seat adapter plate, bearings, retainer ring, seal and O-Rings. Part number 1769-X_2. b. Field replacement seal assembly containing only the seal and O-Rings. Part number 1769-XR_2. 1
_denotes O-Ring code
2
O-Ring Code
16
1358
Grease Seal
2
—
A
Buna-N
17
1164-1
Bearing Cap
2
—
B
Neoprene ® 6
D
Vitron ® 6
E
Teflon ® 6
18
2158
Grease Zerk 1/8” NPT
2
—
19
1769
Bearing Housing
2
—
20
1343
Relief Fitting (Seal Vent)
2
—
1769-X_1, 2, a 1769-XR_1,2,a 1163-28 1209-18 1161-4 1205-4 2754-X 2755 2754
Seal Assembly Seal Assembly—Replacement Sideplate (521) Sideplate (1021) Head (521) Head (1021) Roller Bearing—Complete Bearing Inner Race Bearing Outer Race
2 2 2 2 2 2 2 2 2
181126 181127 — — — — — — —
21 22 23 24
Optional flanges, (model 521): 1172-1.5 1/2” NPT 1172-1.5S 1/2” Weld 1172-2 2” NPT 1172-2S 2’ Weld 1172-2.5 21/2” NPT 1172.2.5S 2 1/2” Weld
3
25
2760-244
Retainer Ring
2
—
26
1343
Relief Fitting (Grease)
2
—
27
2-128_7
Shaft O-Ring
2
—
28
1882
Seal Adapter Plate
2
—
29
2-240_2
Adapter Plate O-Ring
2
Optional flanges, (model 1021): 1206-3S 3” Weld 1206-4 4” NPT 1206-4S 4’ Weld
—
5
30
2-261_ 2-268_2
Case O-Ring (521) Case O-Ring (1021)
2 2
181153 —
31
2270
1/4” Key
2
—
32
2949
Nameplate
1
—
7
33
3442
1/4” NPT Plug
1
—
8
200
2, a
Gas Equipment Catalog
Qty Webb#
4
Not available separately.
Neoprene®, Viton®, and Teflon® are registered trademarks of the Dupont company. 6
Available in Buna-N only. Sideplate replacement instructions. victormfg.com
SECTION
9
Repair Parts
Parts Details For Models Z/ZH3200 28 (60 ft•lb) 25 (25 ft•lb) 22 12 4
Inlet
4
29 (15 ft•lb) 28 (60 ft•lb)
O-Ring Code Buna-N
B
Neoprene ® 1
D
Vitron ® 1
Note: Hydraulic motor is not shown.
E
Teflon
See repair/re-build kits.
Outlet (25 ft•lb)
®1
CAUTION: Always relieve pressure in the unit before attempting any repairs.
MFR#
Description
1
4495-X2R
Rotor Shaft Assembly
1
2
4242
Cam
3
4232
Vane5
1
3 4 6
Qty Webb#
Ref#
MFR#
Description
—
22
2-262_
O-Ring—Case4
2
1
181217
23
2-224_
O-Ring_Relief Valve Cap4
1
—
6
254235
24
Relief Valve Spring
1
—
25
1240 7001037NC150A 2158
Bolt—3/8 – 16X11/2” Hex Head
16
—
1/8” NPT Grease Zerk
2
—
1/8” NPT Relief Fitting
4
—
Bolt—1/2 – 13X11/2” Hex Head
16
—
Bolt—5/16 – 16X11/4” Hex Head
4
—
4
4231
Sideplate
2
—
5
4488
Head
2
—
6
4239
Case
1
—
7
4417
Bearing Cap
2
—
8
4438
Grease Seal
2
—
26 27
Qty Webb# —
9
4435
Mounting Ring
2
—
Bearing Shim (.002) Red Bearing Shim (.010) Brown Bearing Shim (.020) Yellow
29
10
4439 4439-1 4439-2
As Req.
— — —
30
1343 7001050NC150A 7001031NC125A 1241
Relief Valve
1
—
31
4243
Outlet Flange—2” NPT Ell2
1
—
11
2270
Shaft Key
2
—
32
4241
Cam Key
1
—
12
4431-X_a, 2
Mech. Seal Assembly4
2
254236
33
3253
Cam Key Pin
1
—
28
13
2754
Bearing Outer Race
2
—
34
3442
1/4” NPT Pipe Plug
1
—
14
4432
Thrust Bearing Assembly
2
—
35
4262-X
Vane Driver
3
254237
15
2760-244
Retainer Ring
2
—
36
2-234_
O-Ring—Flange4
1
—
16
1174-2
Relief Valve Cap
1
—
37
2159
Lubricap
2
—
17
1359
Lubrication Instruction Plate
2
—
38
1172-2
Aux. Inlet Flange—2” NPT3
1
181084
18
Grease Seal
2
—
39
2649
Nameplate
1
—
4248
Relief Valve Nameplate
21
—
1 As Req. 8
—
20
4441 7012006SF019E —
Screw
8
—
40
Not Shown
—
—
41
4282
Relief Valve Shim
Not Shown
—
—
42
7206-037A
3/8” Lockwasher
— —
Registered trademarks of the DuPont Company. Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), 2” NPT (1172-2) and 1.5” NPT EII (1942). Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), blind (1920-3) and 2” NPT EII (4243). _denotes O-Ring code. See chart above. Slots in varies must face TOWARDS the direction of rotation.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
201
pumps/compressors
Ref#
19
2
A
9
SECTION
9
Repair Parts Parts Details For Models Z3500
O-Ring Code Buna-N
B
Neoprene ® 1
D
Vitron ® 1
Note: Hydraulic motor is not shown.
E
Teflon
See repair/re-build kits.
®1
CAUTION: Always relieve pressure in the unit before attempting any repairs.
Ref#
MFR#
Description
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
2-228 2-245 2-259 2-268 1206-4 1207-2 1208-1X6R 1224 1309 1343 1359 2158 2159 2270 2649 2754 2760-244 3253 3442 3935 3936 4248 4417 4432
O-Ring4 O-Ring4 O-Ring4 O-Ring4 Inlet Flange—3” NPT2 Relief Valve Cap Rotor Shaft Assembly Relief Valve Cam Key Grease Relief Fitting Lubrication Plate Grease Zerk Lubricap Shaft Key — 1/4” Nameplate Outer Bearing Retainer Ring Cam Key Pin Pipe Plug—1/4” NPT Sideplate Vane5 Relief Valve Warning Tag Bearing Cap Thrust Bearing Assembly
1
3 4 6 2
A
Qty Webb# 1 1 1 2 1 1 1 1 1 4 2 2 2 1 1 2 2 2 2 2 6 1 2 2
— — — — — — 181089 — — — — — — — — — — — — — — — — —
Ref#
MFR#
Description
25 26 27 28 29 30 31 32
Thrust Bearing Mounting Ring Greas Seal/Oil Seal Bearing Cap Shim—0.002” Bearing Cap Shim—0.010” Bearing Cap Shim—0.020” Grease Seal Mechanical Seal Assembly4 Coro-Vane Shaft Cover
2 2 2 2 2 2 2 1
— — — — — — — —
Hex Head Bolt
24
—
Hex Head Bolt
18
—
Hex Head Bolt
4
—
Screw
9
—
Screw
2
—
38 39 40 41
4435 4438 4439 4439-1 4439-2 4441 4431-X2 4985 7001037NC125A 7001037NC150A 7001037NC175A 7012006SF019E 7012010SF050E 7206-037A 5534 5537 5539
Lock Washer—0.375” Head Case Cam
8 2 1 1
— — — —
42
5538
Outlet Flange—3” NPT Elongated3
1
—
43 44
5548 5554-X
Spring Vane Driver
1 6
— —
33 34 35 36 37
Qty Webb#
Registered trademarks of the DuPont Company. Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), 2” NPT (1172-2) and 1.5” NPT EII (1942). Optional 1.5” NPT (part# 1172-1.5), 1.5” WF (1172-1.5S), 2” WF (1172-2S), blind (1920-3) and 2” NPT EII (4243). _denotes O-Ring code. See chart above. Slots in varies must face TOWARDS the direction of rotation.
202
Gas Equipment Catalog
victormfg.com
SECTION
9
Repair Parts
Repair Kits and Spare Parts For Stationary Coro-Vane® Pumps C51/F51 Standard Repair Kits (no kit available) MFR# 2296-1X_5 2451-2 2-154_ 2491
Description Seal Assembly Vane Case O-Ring Sideplate
C51/F51 Additional Spare Parts
Qty Webb# 1 8 2 2
— — — —
521 Repair Kit 2904-X21 Description Sideplate Vane Grease Seal Seal Assembly (Replacement) O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N Flange Gasket Grease Seal, Thrust Roller Bearing
Description Sideplate Vane Grease Seal Seal Assembly (Replacement) O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N Grease Seal, Thrust Roller Bearing
Qty Webb# 2 10 2 2 1 1 181179 2 2 2 3 1 2
1358 1769-XRA 2-234A 2-238A 2-245A 2-249A 2-268A 2014 2754 3209 3476-L 3476-R 3477
Description Grease Seal Seal Assembly (Replacement) O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N O-Ring, Buna-N Grease Seal, Thrust Bearing Outer Race Ball Bearing Sideplate, Left Sideplate, Right Vane
Rotor & Shaft Assembly Roller Bearing
1 2
— —
MFR# 1166-1X1R 1162-2
Description
Qty Webb#
Rotor & Shaft Assembly Cam (Liner)
1 1
— 181078
1021/F1021 Additional Spare Parts
Qty Webb# 2 10 2 2 1 1 181182 2 2 2 1 2
MFR# 1208-1X1R 1201-2
Description
Qty Webb#
Rotor & Shaft Assembly Cam (Liner)
1 1
181089 181086
9
F1521 Additional Spare Parts
F1521 Repair Kit 2907-X31 MFR#
2492-X 2471
Qty Webb#
521 Additional Spare Parts
1021/F1021 Repair Kit 2906-X2 MFR# 1209-1 1308-9 1358 1769-XRA 2-112A 2-228A 2-245A 2-249A 2-268A 2014 2754-X
Description
Qty Webb# 2 2 3 1 1 1 2 1 2 1 1 1 6
— — — — — — — — — — — — —
MFR# 3350-X1R 1792-1
Description Rotor & Shaft Assembly Cam (Liner)
Qty Webb# 1 1
— —
1 All repair kits have Buna-N O-Rings which are suitable for both LPG and NH3 applications.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
pumps/compressors
MFR# 1163-2 1168-7 1358 1769-XRA 2-112A 2-224A 2-227A 2-234A 2-261A 2010 2014 2754-X
MFR#
203
SECTION
9
Repair Parts Repair/Re-build Kits Z2000, ZH2000, ZX2000, ZXH2000 Repair Kit 3193-X1 MFR# 2-224A 2-231A 2754-X 4262-X 4428 4431-XA2 4432 4435 4439 4439-1 4439-2 4441 2270
Description O-Ring, Buna-N O-Ring, Buna-N Roller Bearing Vane Driver Vane Seal Assembly Thrust Bearing Thrust Bearing Mounting Ring Bearing Cap Shim (0.002) Bearing Cap Shim (0.010) Bearing Cap Shim (0.020) Grease Seal Shaft Key
Qty Webb# 1 2 2 3 6 2 2 2 8 2 2 2 1
— — — — — — — — — — — — —
Z3200, ZH3200 Repair Kit 3195-X1 MFR# 2-224A 2-234A 2754-X 4262-X 4232 4431-XA2 4432 4435 4439 4439-1 4439-2 4441 2270
Description O-Ring, Buna-N O-Ring, Buna-N Roller Bearing Vane Driver Vane Seal Assembly Thrust Bearing Thrust Bearing Mounting Ring Bearing Cap Shim (0.002) Bearing Cap Shim (0.010) Bearing Cap Shim (0.020) Grease Seal Shaft Key
Qty Webb# 1 2 2 3 6 2 2 181237 2 8 2 2 2 1
2-228A 2754-X 5554-X 3936 4431-XA2 4432 4435 4439 4439-1 4439-2 4441 2270
Description O-Ring, Buna-N Roller Bearing Vane Driver Vane Seal Assembly Thrust Bearing Thrust Bearing Mounting Ring Bearing Cap Shim (0.002) Bearing Cap Shim (0.010) Bearing Cap Shim (0.020) Grease Seal Shaft Key
MFR# 2-231A 2-234A 4460-X 4449-X 4448 4464-XA2 4453 4454 4458 4458-1 4458-2 4463 4459
Qty Webb# 2 2 3 6 2 2 2 8 2 2 2 1
— — — — — — — — — — — —
MFR# 4414 4427
204
Gas Equipment Catalog
O-Ring, Buna-N O-Ring, Buna-N Roller Bearing Vane Driver Vane Seal Assembly Thrust Bearing Thrust Bearing Mounting Ring Bearing Cap Shim (0.002) Bearing Cap Shim (0.010) Bearing Cap Shim (0.020) Grease Seal Shaft Key
Qty Webb# 1 2 2 5 6 2 2 2 8 2 2 2 1
— — — — — — — — — — — — —
Description Cam Sideplate
Qty Webb# 1 2
— —
Z3200, ZH3200 Re-Build Kit 3196-X1 includes all items in the Whole Kits Repair Kit (#181238)plus the following: MFR#
Description Cam Sideplate
Qty Webb# 1 2
181217
Z3500 Re-Build Kit 3196-X2 includes all items in the Repair Kit plus the following: MFR# 5539 3935
Description Cam Sideplate
Qty Webb# 1 2
— —
Z4200, ZH4200, Z4500 Re-Build Kit 3198-X1 includes all items in the Repair Kit plus the following: MFR#
1 All repair kits have Buna-N O-Rings which are suitable for both LPG and NH3 applications.
Description
Z2000, ZH2000, ZX2000, ZXH2000 Re-Build Kit 3194-X1 includes all items in the Repair Kit plus the following:
4242 4231
Z3500 Repair Kit 3195-X2 MFR#
Z4200, ZH4200, Z4500 Repair Kit 3197-X1
4443 4446
Description Cam Sideplate
Qty Webb# 1 2
— —
victormfg.com
SECTION
10
Generators Guardian® Series Standby Generators The G3B is a power gas burner for natural or propane gas—completely assembled, using premix combustion and hot surface ignition with lame rectification flame sensing. Features: • True Power electrical technology • Two line LCD Tri-lingual digital Nexus controller • Electronic governor • External main circuit breaker and system status LED indicators 14KW Steel
20KW Aluminum
• Flexible fuel line connector • Composite mounting pad • Natural gas or LP gas operation • 3 Year limited warranty • UL 2200 listed
Generac Whole-House Propane / Natural Gas Generators MFR# GRC5882 GRC5883 GRC5884 GRC5885 GRC5886 GRC5887 GRCQT02516
DESCRIPTION AIR CLD GENERATOR 8KW STEEL AIR CLD GENERATOR 10KW STEEL AIR CLD GENERATOR 14KW STEEL AIR CLD GENERATOR 17KW STEEL AIR CLD GENERATOR 17KW ALUM AIR CLD GENERATOR 20KW ALUM LIQ COOLED GENERATOR 25KW STEEL
WEBB# 361729 361730 422548 361732 422549 422550 361734
Generac Load Centers DESCRIPTION 10-CIRC LOAD CENTER ATS NEMA 1 12-CIRC LOAD CENTER ATS NEMA 1 14-CIRC LOAD CENTER ATS - NEMA 1 16-CIRC LOAD CENTER ATS NEMA1 100 AMP SERV ENTR 120/240 1 NEMA 3R 200 AMP SERV ENTR 120/240 1 NEMA 3R 100 AMP 120/240 1 NEMA 3R 200 AMP 120/240 1 NEMA 3R 100 AMP 120/208 3 NEMA 3R 200 AMP 120/208 3 NEMA 3R 200 AMP 120/240 3 NEMA 3R PWR MGR 200A AMP 120/240 1 NEMA 3R
WEBB# 361743 361744 422564 361745 368691 361746 422567 422571 422568 422572 422573 422566
Misc Equipment
MFR# GRCRTS10EZA1 GRCRTS12EZA1 GRCRTS14EZA1 GRCRTS16EZA1 GRCRTSD100A3 GRCRTSD200A3 GRCRTSN100A3 GRCRTSX200A3 GRCRTSN100G3 GRCRTSN200G3 GRCRTSN200J3 GRCRTSS200A3
10 Generac Portable Gasoline Generators MFR# GRC5793 GRC5939 GRC5940
DESCRIPTION IX2000 PORT GEN 2000 WATTS GP5500 PORT GEN 5500 WATTS GP6500 PORT GEN 6500 WATTS
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
WEBB# 422562 422552 422553
205
SECTION
10
Generators ETQ Generators MFR# IN1800I TG32P12 TG72K12 TP30P11 PG60B12 W0001-T40-00
DESCRIPTION 1800W CLOSED FRAME GASOLINE 4000W OPEN FRAME GASOLINE 8250W OPEN FRAME GASOLINE 3500W OPEN FRAME LP 7000W OPEN FRAME LP WHEEL KIT FOR TP30P11
IN1800I
TG32P12
WEBB# 411953 411954 420781 411955 435132 415973
TP30P11
TG72K12
PG60B12
Generator Usage Chart Nat gas usage (btu/hr 1000's)
LP usage gal/hr (btu/hr 1000's)
Air cooled
Half load
Half load
Half load
7 KW
66
119
.82 (75)
1.47 (135)
10 KW
102
156
1.25 (115)
1.93 (178)
13 KW
156
220
1.55 (143)
2.18 (200)
16 KW
173
245
1.59 (147)
2.51 (231)
18 KW
181
262
1.97 (182)
2.85 (262)
Nat gas usage (btu/hr 1000's)
Half load
LP usage gal/hr / (btu/hr 1000's)
Liquid cooled
Exercise
Half load
Full load
18 KW
48
165
278
.52 (48)
1.8 (166)
3.04 (280)
20 KW
60
188
315
.65 (60)
2.05 (189)
3.44 (317)
25 KW
60
253
437
.65 (60)
2.77 (255)
4.81 (443)
30 KW
56
281
437
.65 (60)
3.17 (293)
5.0 (461)
45 KW
102
373
720
1.11 (102)
4.07 (375)
7.86 (723)
60 KW
123
500
960
1.34 (124)
5.46 (503)
10.48 (965)
70 KW
110
499
1020
1.20 (111)
5.46 (503)
11.17 (1028)
80 KW
131
600
1154
1.45 (134)
6.64 (611)
12.78 (1176)
100 KW
140
713
1374
1.53 (141)
7.81 (719)
15.05 (1385)
130 KW
135
927
1786
1.48 (137)
10.15 (934)
19.56 (1800)
150 KW
155
1070
2061
1.70 (157)
11.72 (1079)
22.57 (2077)
206
Gas Equipment Catalog
Exercise
Half load
Full load
victormfg.com
SECTION
10
Gas Burner G3B Power Gas Burner 60K - 180K BTU
The G3B is a power gas burner for natural or propane gas—completely assembled, using premix combustion and hot surface ignition with lame rectification flame sensing. Features: • Converts from propane to natural gas with just an orifice change— no conversion kit needed. • Factory-packaged with combustion control and gas fuel train. • 60,000 to 180,000 Btuh—ideal for small to large homes. • Quiet and clean. • Dependable, hot surface ignition for quick, clean light-off. • Compact, efficient flame pattern. • Does not require a refractory liner—fires with or without a combustion chamber. • Ideal for high-efficiency wet-based boilers. • Superior for use in 2, 3, 4 or 5-section boilers. • Calibrated air throttle for easy adjustment. • Universal mounting flange. • Low-energy motor—only 0.40 amp. • Includes 1-year warranty. mfr# description webb# 74245 G3B With 6” Tube 185221 74252 G3B With 9” Tube 95235
EZ-Gas Power Gas Burner 50K - 275K BTU
mfr# description webb# 9859210AFR1A EZ-Gas 10” A 150K - 275K 379487 9859210BFR1 EZ-Gas 10” B 50K - 175K 379488
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
207
Misc Equipment
Features: • Converts from propane to natural gas with just an orifice change— no conversion kit needed. • Fires negative or positive chambers from 50,000 to 275,000 Btuh input. • Provides dependable, direct-spark ignition of main flame—for quick, clean light offs. • Comes standard with time-tested solid state ignition and state-of-the-art microprocessor control technology. • Factory-packaged with combustion control and gas fuel train. • Shipped completely assembled and wired—for “EZ” installation and start-up. • Diagnostic LED lights annunciated operating mode: Self-check, Flame-on, Recycle, Lockout and Latch-up. • High-efficiency, compact flame pattern design ensures clean, quiet operation. • Does not require a refractory liner—fires with or without a combustion chamber. • Available with custom welded air tube flange (and/or optional pedestal) to accommodate most appliance mounting requirements. • Includes 1-year warranty.
10
SECTION
10
Vaporizers Direct Fired LPG Vaporizers
A propane vaporizer is actually a boiler. Instead of boiling water, it boils propane. It may sound strange that heat is required to vaporize propane when propane will boil at -44 F, but, when propane vaporizes by expansion alone, it causes a refrigeration action. In applications with high propane demand, the uncontrolled vaporization would freeze valves and burner nozzles. Therefore, heat is required to offset the refrigeration action. Direct fired vaporizers use a portion of the propane they vaporize to supply the heat for the vaporization process. AES direct fired vaporizers can be used to vaporize all forms of LPG (Liquefied Petroleum Gas), including Propane, Butane, Propylene, etc. • For Propane, Butane, & other LPG • Two-Stage Burner • Dual Liquid Level Control • Piezo Ignitor mfr# ALT1206H ALT4040H ALT8040H
WEBB# 424131 424133 424132
Capacity 120 gal/hr (10.9 MBH) 40 gal/hr (3.6 MBH) 80 gal/hr (7.3 MBH)
Comparative Thermal Value of Fuels Natural Gas.........................................................100,000 BTU’s =1 Therm Fuel Oil...............................................................42 Gallons = 1 barrel Gas Conversion Factors 1 Cubic Foot (CF)................................................Approximate 1,000 BTU’s 100 CF.................................................................100,000 BTU’s 1 Therm..............................................................100,000 BTU’s 10 Therms...........................................................1 Decartherm (DTH) 1 DTH.................................................................1,000,000 BTU’s 1 DTH.................................................................1 MM BTU Approximate Conversion Propane/Gallon..................................................91,500 BTU’s = .915 Therms/Gallon Butane/Gallon....................................................103,000 BTU’s = 1.03 Therms/Gallon #2 Heating Oil/Diesel/Gallon...........................138,500 BTU’s = 1.385 Therms/Gallon #6 Fuel Oil/Barrel..............................................6,350,000 BTU’s = 63.5 Therms/Gallon Coal (Short Ton).................................................21,900,000 BTU’s = 219 Therms/Short Ton 1 Truck & Trailer of Propane (9,300 Gallons) = 8,510 Therms 1 Truck & Trailer of Butane (9,300 Gallons) = 9,274 Therms 1 Truck & Trailer of Diesel (8,000 Gallons) = 11,080 Therms 1 Truck & Trailer of #6 Fuel (7,000 Gallons) = 10,500 Therms Convert Cents/Gallon to $/MM BTU Multiply Cents/Gallon by: Ethane.................................................................15.24 Gallons/MM BTU Propane...............................................................10.93 Gallons/MM BTU Normal Butane...................................................9.71 Gallons/MM BTU Iso-Butane...........................................................10.12 Gallons/MM BTU Mixed Butane (75/25).........................................9.81 Gallons/MM BTU Natural Gasoline.................................................8.00 Gallons/MM BTU #2 Oil..................................................................7.22 Gallons/MM BTU Convert $/Bbl to $/MM BTU Divide $Bbl by: #6 Oil..................................................................6.35 MM BTU/Barrel #6 Oil..................................................................151,190 MM BTU/Gallon
208
Gas Equipment Catalog
victormfg.com
10
Disconnects Hansen Gas-Mate Coupling
One-way shut-off Safety Couplings are designed for LP and natural gas applications where 3/8”, 1/2”, 3/4”, 1”, and 11/4” hose is used. 1/2 PSI Max Pressure. MFR#
Female End Conn. Dimensions Webb#
100-006 100-008 100-010 100-506 100-508 100-510
3/8” FPT, Socket Only 1/2” FPT, Socket Only 3/4” FPT, Socket Only 3/8” FPT, Plug Only 1/2” FPT, Plug Only 3/4” FPT, Plug Only
202616 182153 182146 182158 182154 182147
2.44 X 1.13 X 1.00 2.84 X 1.38 X 1.13 3.17 X 1.75 X 1.50 1.59 X 0.94 X 0.81 1.94 X 1.16 X 1.00 2.06 X 1.52 X 1.31
Burnaby Gas Outlet Box Model #G0101-5 Completely enclosed in a UV and fire protectant PVC box, manufactured to ISO 9220 standard, the gas outlet is an ideal means of safely and securely connecting your gas barbecue, patio heater, stove or dryer directly to your residential gas supply. • Eliminates refilling tanks, gas identification • Quick disconnect safety shutoff with easy access • C/W standoffs for siding installation • CGA & AGA approved for Indoor/Outdoor use • Approved for temperatures to -40° • Inlet connection – 3/8” N.P.T. • Hose connection – 3/8” Quick Disconnect • 75 MBH natural gas/118 MBH • Stainless models have lockable door To complete this installation, add: Mfr# SAE38X38MUN VCT50A1900030 VCT50A1900100 VCT50A1900101 Mfr# G0101-SS-50 GR0101-SS GR0101-SS-50 G0101-DBL-SS G0101-5W-50
6’ Hose
12’ Hose 18’ Hose
Webb#
Misc Equipment
And a hose:
Description
3/8” Female X Male Union
370042 370041 370040
Description
Webb# 283797 3/8” Recessed Mount SS 283798 1/2” Recessed Mount SS 283799 1/2” Surface Mount Double Connector 283800 191025 6” X 41/2” X 21/2”, 1/2” Surface Mount, White 1/2” Surface Mount SS
10
Gas Outlet Mfr# MXTGC10AA01
Description Plug1 Gas Outlet
Webb# 412565
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
209
SECTION
10
Gas Lights Galaxy Lights By Faulk MFR#
Description
Webb#
vct2703 vct2705 vct4globe
Single Wall Light Double Wall Light Glass Globe
316096 367629 316225
Lights Mfr# F220325 F220300 F220353 F220351 F220370 F220330
Description Light Indoor (Gray) Light Indoor (Brass) Soft Tie on Mantle Performed Mantle Chandelier Kit Glass Globe
Webb# 395850 396327 395846 395848 395849 395843
Rutland Fireplace Products Mfr# VCT304 VCT565 VCT570-6 VCT585 VCT587 VCT595 VCT63-G VCT641 VCT82 VCT83-6
210
Description Webb# CHIMNEY PAINT SS 401840 WHT OFF GLASS CLEANER 401841 GAS LOG SOOT REMOVER 401844 GLW EMBRS 12OZ TUB 433550 ROCK WOOL 401839 LAVA ROCK 401838 FIREPLACE MORTAR GRAY 408107 SEAL IT RIGHT 800F BLK LATEX 401843 FIREPLACE GLASS CLEANER 401842 BRICK & STOVE CLEANER 408108
Gas Equipment Catalog
victormfg.com
SECTION
11
Serviceman’s Tools
Leak Detector
Propane Flare
Dispenser With Brush
8 oz. Bottle & Dauber
Gallon MFR# TSTLTG4 TSTTLPINTUNLABE TSTBTL8DBRUNPRI TSTSTL16CYLUNPR
Description All Season, Gallon 16 oz. Bottle With Brush 8 oz Bottle With Dauber 16 oz. Bottle With Spray
Leak Tester Kit mfr# VCTPTK
DESCRIPTION webb# Tester Gas Kit 315690
WEBB# 184312 184310 184311 184309
• Electronic Ignition and proof of flame. • Safety feature offers automatic relight attempt — complete shutdown if unsuccessful. • Burns up to 529 gallons per hour. • Burns liquid or vapor propane. • Over 48,000,000 BTU/hr (1/2” Flare). • Flare burner stands 12’ above ground surface • 12’ power cord for 115 volt A.C. • 20’ remote switch cord. • Stable triangular base. • Setup in 5 minutes.
Available in three line sizes 1/4” • 3/8” • 1/2” MFR# PF-12 LPS PF-38 LPS PF-16 LPS
SIZE BTU/hr
Gals/hr Weight WEBB# Burns 75 100.5 lbs — 3/8” Flare 38,000,000 Burns 416 103.0 lbs — 1/2” Flare 48,300,000 Burns 529 105.5 lbs — 1/4” Flare 6,900,000
ARIBee Bopper II Wasp and Hornet Spray #61011 Beware of the wasp with an attitude. Bee Bopper II will knock him right out of the sky. With Bee Bopper II, you can spray the nest from 20 feet away. Bee Bopper II kills bees and hornets too.
Leak Detector Mfr# description webb# HER45-801 8 oz. 11293
Aim & Flame Lighters mfr# Desc. VCTAF Childproof VCTHW6T —
Webb# 184435
Webb# 184412 266447
Test Gauge Kit
Match Lighter Mfr# Z6-413
Webb# 193250
Tools & Chemicals
Mfr# Size VCT61011 14 oz.
11 mfr# PIGME295-1 VCT18SHVLV VCTPTG RIT00706
Description
1/8” MPOL X FPOL, No Plug 1/8” Union MPT Half
Pressure Test Gauge (0 – 300#) Hose Only
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Webb# 303222 430102 394983 379916
211
SECTION
11
Serviceman’s Tools Low Pressure Test Set
This kit provides the equipment necessary for checking regulator delivery pressure (low pressure) at the appliances. The basic set contains a 2434A-2 low pressure gauge and a 3 foot — 3/16” O.D. flexible synthetic rubber tube. Adapters are also available. 2962
mfr# EM150 EM200
EM150
EM200
Features: • Measures postitive and negative pressure 20” water gauge. • Auto power off. • Rubber-boot with built-in magnet. • .05” resolution below 9.95”.
Features: • Dual scale: 60” water gauge and 150 mBar .01” wg resolution below 9.99”. • Ruggedized with sturdy metal fittings. • Rubber-boot with built-in magnet. • Min/Max. • Data hold. • Auto power off. • Back-lit display. • One year limited warranty. EM200
2434A
EM150
1212 KIT MFR#
Description
Webb#
2434A
Test Kit
162825
SJIGPTK
Test Kit
204982
1328
3/8” OD Adapter
162816
1331
1/2” OD Adapter
162817
1332
5/8” OD Adapter
162818
High Pressure Gauge Adapter
Inlet Outlet MFR# Connection connection 2962
Soft Nose M. POL
F. POL
Webb#
0 to 300
162829
The water manometer kit is especially suited for use with low pressure LP-Gas systems. It is ideal for pressure checks downstream of the low pressure regulator and at the appliances. Description
Webb#
Flexible Tube Water Manometer Kit
162815
MFR#
Description
Webb#
DWY1222-16
U Tube Manometer
185267
1212 KIT
Dwyer
212
Description
Webb#
DWY2030
0-30” Magnehelic Differential Gauge
2251109
DWYA432
Carry Case/Hoses for 2030 Gauges
359347
Quick Look 72
Pressure Gauge Range (PSIG)
Water Manometer Kit
MFR#
Series 2000 Magnehelic Differential Presssure Gauge MFR#
Designed for testing high pressure lines. Adapter has 0 to 300 PSIG gauge. A bleeder valve allows you to bleed down to correct pressure during pressure tests.
Webb# 193481 284231
Gas Equipment Catalog
mfr# 720001W
Webb# 360275
MetroTel Corp Cable Hound DSP
The Cable Hound DSP is an electronic device designed to accurately locate and determine depth of buried cable or metallic pipe. Features: • Improved depth and distance capabilities. • New receiver with digital signal processing (DSP). • Auto-Off switch saves battery life. • Quality padded headphones included. • Improved, more convenient case. mfr# MT99-0118
Webb# 308931
victormfg.com
SECTION
12
LP Container Requirements
Filling Instructions for the Vacuum Pre-Purged Propane Tank CAUTION: • Do not remove seals on valves before being properly instructed on how to initially fill a vacuum pre-purged propane tank. • Do not let any air enter the propane tank. If air is allowed in the tank before the pressure is normalized, it must be re-purged with propane vapor in accordance with NFPA Pamphlet #58 and government regulatory requirements. • Do not remove cap from fill valve until the vacuum has been neutralized. Begin filling through the service valve (a/k/a the multivalve) for the first fill or at least until the vacuum is neutralized. • Do not open the outage valve until the pressure in the tank has normalized or a positive pressure has been achieved in the tank. • The presence of a vacuum in the tank does not eliminate the need for the introduction of methanol into the tank. • Never prepare the propane tank for service on a customer’s property, but always at the bulk plant site or some other safe location. 1) 2) 3) 4) 5)
Verify that a vacuum exists in the tank. Remove the seal wrap from the service valve and verify that the service valve hand wheel is tightly closed. Connect a vacuum pressure gauge to the service valve outlet connection and open the hand wheel. Visually check the vacuum pressure gauge dial for the presence of a vacuum. Close the service valve and disconnect the vacuum pressure gauge. NOTE: If the vacuum is not in accordance with NPGA Safety Bulletin No. 133-89(a), the container must be re-purged with propane vapor.
The Tank Has Now Been Prepared For Service. • To transport the tank after preparation process, remove all propane gas in the tank in excess of the amount of propane permitted to be transported under applicable regulations, including those of the U.S. Department of Transportation. • Once the tank has been safely set for service, you may continue the filling process through the fill valve by removing the seal and cap of the fill valve and using your normal safe filling procedures.
CAUTION: The initial fill must be to the maximum allowable liquid level to counteract the possible depletion of ethyl mercaptan in the tank.
• If you did not do so earlier, you may also inject methanol into the tank at this point by including an injection device in your fill line. • Future fillings should be made through the fill valve.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
appendices
6) Add methanol to the propane tank by connecting a hose to the POL outlet of the service valve. 7) Submerge the other end of the hose in a safety container that has been filled with the required measure of methanol. 8) Gradually open the service valve and the metha nol will be drawn into the tank to partially fill the vacuum that exists. 9) To prevent air from getting into the propane tank, close the service valve as soon as the measured amount of methanol has been removed from the safety container. 10) Disconnect the methanol hose from the POL of the service valve. 11) Connect the propane fill hose to the POL connector on the service valve.
12) Open the service valve and start to fill the tank with propane. CAUTION: After the tank pressure has been normalized, close the outage valve (if it was opened after the pressure was normalized), the service valve and the fill hose valve. NOTE: The appropriate amount of propane to normalize the vacuum pressure in the tank will vary depending on the volume of the tank. If liquid is used, 1 to 4 gallons of propane is required for all tanks up to 1000 gal. water capacity. If vapor is used, wait until there is no longer an audible transfer of vapor from the filler hose to the tank. 13) Bleed off the fill connector pressure and disconnect.
12 213
SECTION
12
LP Container Requirements Liquified Petroleum Gas Code* Storage Within Residential Buildings. Storage of cylinders within a residential building, including the basement or any storage area in a common basement storage area in multiple-family buildings and attached garages, shall be limited to cylinders each with a maximum water capacity of 2.7 lb (1.2kg) and shall not exceed 5.4-lb (2.4-kg) aggregate water capacity for smaller cylinders per each living space unit. Each cylinder shall meet DOT specifications. 5.4 Storage Outside of Buildings.
Location of Storage Outside of Buildings. Storage outside of buildings for cylinders awaiting use, resale, or part of a cylinder exchange point shall be located as follows. 5.4.1.1 At least 5 ft. (1.5 m) from any doorway or opening in a building frequented by the public where occupants have at least two means of egress as defined by NFPA 101, Life Safety Code. For buildings, or sections of buildings, having only one means of egress, at least 10 ft. from the doorway or opening. 5.4.1.2 At least 20 ft. from any automotive service station fuel dispenser. 5.4.1.3 In accordance with Table 5.4.1.3 with respect to the following: (1) Nearest important building or group of buildings. (2) Line of adjoining property that may be built upon. (3) Busy thoroughfares or sidewalks. (4) Line of adjoining property occupied by schools, churches, hospitals, athletic fields, or other points of public gathering. (5) Dispensing station. Exception: Cylinders in the filling process shall not be considered to be in storage.
5.4.2 Protection of Cylinders. 5.4.2.1 Cylinders at a location open to the public shall be
protected by either of the following: (1) An enclosure in accordance with 3.3.6(a) (2) A lockable ventilated metal locker or rack that prevents tampering with valves and pilferage of the cylinder.
5.4.2.2* Protection against vehicle impact shall be provided
in accordance with good engineering practice where vehicle traffic normally is expected at the location. 5.4.3 Alternate Location and Protection of Storage.
Where the provisions of 5.4.1 and 5.4.2.1 are impractical at construction sites or at buildings or structures undergoing major renovation or repairs, alternate storage of cylinders shall be acceptable to the authority having jurisdiction. 5.5* Fire Protection. Storage locations, where the aggregate quantity of propane stored is in excess of 720 lb. (327 kg), shall be provided with at least one approved portable fire extinguisher having a minimum capacity of 18 lb. (9.2 kg) dry chemical with B-C rating. The required fire extinguisher shall be located no more than 50 ft. (15 m) from the storage location. * This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
Use of Liquid Volume Correction Factors, Table F.3.3. F.4.1 To correct the observed volume in gallons for any LP-Gas (the specific gravity and temperature of which is known) to gallons at 60°F (16°C), Table F.3.3 is used as follows: (a) Obtain the correction factor for the specific gravity and temperature as described in F.3.3. (b) Multiply the gallons observed by this correction factor to obtain the gallons at 60°F (16°C). Example: A container has in it 4055 gal of LP-Gas with a specific gravity of 0.560 at a liquid temperature of 75°F. The correction factors in the 0.560 column are 0.980 at 76°F and 0.983 at 74°F, or, interpolating, 0.9815 for 75°F. The volume of liquid at 60°F is 4055 x 0.9815, or 3980 gal. F.4.2 To determine the volume in gallons of a particular LP-
Gas at temperature t to correspond with a given number of gallons at 60°F (16°C), Table F.3.3 is used as follows: (a) Obtain the correction factor for the LP-Gas, using the column for its specific gravity and reading the factor for temperature t. (b) Divide the number of gallons at 60°F (16°C) by thiscorrection factor to obtain the volume at temperature t.
Table 5.4.1.3 Distances from Cylinders in Storage and Exposures Quantity of LP-Gas Stored lb kg £720 £227 721 to 2,500 227+ to 1,134 2,501 to 6,000 1,134+ to 2,721 6,001 to 10,000 2,721+ to 4,540 >10,000 >4,540
214
Horizontal Distance to . . . (1) & (2) (3) & (4) (5) ft m ft m ft m 0 0 0 0 5 1.5 0 0 10 3 10 3 10 3 10 3 10 3 20 6.1 20 6.1 20 6.1 25 7.6 25 7.6 25 7.6
Gas Equipment Catalog
victormfg.com
SECTION
12
LP Container Requirements
Liquified Petroleum Gas Code* Example: It is desired to pump 800 gal (3.03 m3) at 60°F (15.5°C) into a container. The LP-Gas has a specific gravity of 0.510, and the liquid temperature is 44°F. The correction factor in the 0.510 column for 44°F is 1.025. Volume to be pumped at 44°F is 800/1.025 = 780 gal (2.95 m3).
F.5 Maximum Liquid Volume Computations. F.5.1 Maximum Liquid LP-Gas Content of a Container at Any Given Temperature. F.5.1.1 The maximum liquid LP-Gas content of any container depends on the size of the container, whether it is installed above ground or under ground, the maximum permitted filling limit, and the temperature of the liquid [see Tables 4.4.2.2(a), (b), and (c).] F.5.1.2 The maximum volume fraction Vt (in percent of container capacity) of an LP-Gas at temperature t, having a specific gravity G and a filling limit and weight percent filling limit of L, is computed by use of the following formula: or:
Vt =
L G
Vt =
L GXF
÷F
where: Vt = percent of container capacity that can be filled with liquid L = maximum permitted filling limit by weight (see Table 4.4.2.1) G = specific gravity of particular LP-Gas F = correction factor to correct volume at temperature t to 60°F (16°C) Example: The maximum liquid content, in percent of container capacity, for an aboveground 30,000-gal (114-m3) water capacity container of LP-Gas having a specific gravity of 0.508 and at a liquid temperature of 80°F (27°C) is computed as follows: From Table 4.4.2.1, L = 0.45, and from Table F.3.3, F = 0.967. Thus,
0.45 0.508 X 0.967 = 0.915 (91%) or 27,300 gal (103 m3)
F.5.2 Alternate Method of Filling Containers. F.5.2.1 Containers equipped with fixed maximum level gauges or with variable liquid level gauges when temperature determinations are not practical can be filled with either gauge provided that the fixed maximum liquid level is installed or the variable gauge is set to indicate the volume equal to the maximum permitted filling limit as provided in 4.4.3.3(a). The level is computed on the basis of the liquid temperature being 40°F (4.4°C) for aboveground containers or 50°F (10°C) for underground containers. F.5.2.2 The percentage of container capacity that can be filled with liquid is computed by use of the formula shown in F.5.1.2, substituting the appropriate values as follows: Vt =
L GXF
where: t = the liquid temperature [assumed to be 40°F (4.4°C) for aboveground containers or 50°F (10°C) for underground containers]. L = the loading limit obtained from Table 4.4.2.1 for: (a) The specific gravity of the LP-Gas to be contained. (b) The method of installation, aboveground or underground, and if aboveground, then: (1) For containers of 1200 gal (4.5 m3) water capacity or less. (2) For containers of more than 1200-gal (4.5-m3) water capacity. G = the specific gravity of the LP-Gas to be contained. F = the correction factor (obtained from Table F.3.3, using G and 40°F (4°C) for aboveground contain ers or 50°F (10°C) for underground containers).
Example: The maximum volume of LP-Gas with a specific gravity of 0.508 that can be in a 1000-gal (3.8-m3) water capacity aboveground container that is filled by use of a fixed maximum liquid level gauge is computed as follows: t = is 40°F (4.4°C) for an aboveground container. L = for 0.508 specific gravity, and an aboveground container of less than 1200-gal (4.5-m3) water capacity, from Table 4.4.2.1, is 42 percent. G = is 0.508. F = for 0.508 specific gravity at 40°F (4.4°C) from Table F.3.3 is 1.033. Thus, V40 =
0.45 0.508 X 1.033 = 0.800 (80%) or 8000 gal (3 m3)
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
215
appendices
V80 =
(continued)
12
SECTION
12
LP Container Requirements
Table 3.2.2.2 Separation Distances Between Containers, Important Buildings, and Other Properties* minimum distances Water capacity per container gal
m3
<125d
<0.5d
mounded or underground containersa ft
125-250
0.5 - 1.0
251-500
1.0+ - 1.9
501-2000
1.9+ - 7.6
m
10
3
aboveground containersb ft
M
FT
M
a
0e
0e
0
0
b
10
3
0
0
10
3
3
1
25
7.6
3
1
2001-30,000
7.6+ - 114
50
15
30,001-70,000
114+ - 265
75
23
70,001-90,000
265+ - 341
100
30
90,001-120,000
341+ - 454
125
38
50
15
120,001-200,000
454+ - 757
200
61
200,001-1,000,000
757+ - 3785
300
91
>1,000,000
>3785
400
122
Table 3.2.2.2(d) Separation Distance Between Container Pressure Relief Valve and Building Openings
distance Horizontally from relief valve discharge to opening below exchange discharge container or filled type on site ft M Cylinder
Exchange
3.0
0.9
discharge fROm relief valve, vent discharge, and filling connection to exterior source of ignition, openings into direct-vent appliances, mechanical ventilation air intakes FT
M
5.0
1.5
Cylinder
Filled On Site
3.0
0.9
10.0
3.0
ASME
Filled On Site
5.0
1.5
10.0
3.0
(f ) Where underground multicontainer installations are made of individual containers having a water capacity of 125 gal (0.5 m3) or more, such containers shall be installed so as to allow access at their ends or sides to facilitate working with cranes or hoists. (g) In applying the distance between buildings and ASME containers of 125-gal (0.5-m3) or more water capacity, a minimum of 50 percent of this horizontal distance shall also apply to all portions of the building that project more than 5 ft. (1.5 m) from the building wall and that are higher than the relief valve discharge outlet. This horizontal distance shall be measured from a point determined by projecting the outside edge of such overhanging structure vertically downward to grade or other level upon which the container is installed.
216
Gas Equipment Catalog
between containersc
See 3.2.2.2 Exception No. 2. See 3.2.2.2 (g). c See 3.2.2.2 (f ). s See 3.2.2.2 (a). e See 3.2.2.2 (b), (c), and (d).
1/4 of sum of
diameters of adjacent containers
Exception No. 1: Not applicable to installations in which overhanging structure is 50 ft. (15 m) or more above the relief valve discharge outlet. Exception No. 2: Where the distance from a 2001 to 30,000 gal. container to a building are in accordance with 3.11.2 and 3.11.4. 3.2.2.3 Where storage containers having an aggregate
water capacity of more than 4000 gal (15.1 m3) are located in heavily populated or congested areas, the siting provisions of 3.2.2.2 and Table 3.2.2.2 shall be permitted to be modified as indicated by the fire safety analysis described in 3.10.2.2. 3.2.2.4 Aboveground multicontainer installations comprised of containers having an individual water capacity of 12,000 gal (45 m3) or more and installed for use in a single location shall be limited to the number of containers in one group, with each group separated from the next group in accordance with the degree of fire protection provided in Table 3.2.2.4. Exception: Where the provisions of 3.11.3 and 3.11.4 are met the minimum separation distance between groups of ASME containers protected by hose stream only shall be one-half the distances in Table 3.2.2.4. 3.2.2.5 Underground or mounded containers shall be located outside of any buildings. Buildings shall not be constructed over any underground or mounded containers. Sides of adjacent containers shall be separated in accordance with Table 3.2.2.2 but shall not be separated less than 3 ft. (1 m). Where underground or mounded containers are installed parallel with ends in line, the number of containers in one group shall not be limited. Where more than one row is installed, the adjacent ends of the tanks in each row shall be separated by not less than 10 ft. (3 m). * This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code â&#x20AC;&#x201D; 2001 Edition
victormfg.com
SECTION
12
LP Container Requirements
Important Safety Information for the Dealer and Your Service and Installation Personnel Why is the fill so important? It is important that the first time a new propane tank is filled that it be filled to its maximum allowable liquid level with propane. This will help counteract the possible depletion of the odorant added to propane as a warning device in the event of a gas leak. Why? This puts the maximum amount of gas in the tank, which in turn puts the highest volume of ethyl mercaptan in the tank at a time when the odorant is most likely to be absorbed, absorbed or broken down by oxidation in the tank. If the odor produced by ethyl mercaptan is allowed to fade too much, its effectiveness as a warning device is diminished or may even be eliminated. The propane dealer should advise and warn the customer: • About the presence of the odorant in propane gas and give the customer a scratch-and-sniff pamphlet to allow those using the propane gas to become familiar with the smell of the odorant. • That the odorant can fade or become less intense. Competing odors and a person’s inability to smell can also mask or cover up propane odor. • Gas detectors may provide an extra measure of safety. • They should not rely only upon the smell of propane for detection of propane gas. Failure to properly advise the users of propane about its properties and those of ethyl mercaptan could lead to a severe fire or explosion hazard, resulting in death or bodily injury. Why is putting methanol in a tank so important? Freeze-ups!!!
Warning and notice about the proper installation of propane tanks designed for use underground. When a tank is designed for use in the underground storage of propane gas, a licensed propane dealer or installer must install it. The party installing the tank must inspect the tank and ensure that at the time of installation the external coating applied to the tank by the manufacturer remains continuous and intact. Failure to install the propane tank with an intact and continuous external coating voids all warranties (but not disclaimers) of the manufacturer. It is the responsibility of the purchaser or installer 1) determine whether additional protection should be used and 2) determine mat the additional protection is compatible with the coating applied by the manufacturer. To help ensure long-term protection of the underground tank, cathodic protection; should be used and may be required by governing authorities having jurisdiction over the installation of underground propane tanks at the installation site. This tank is sold subject to and limited by the terms and conditions of sale, including, but not limited to, the manufacturer’s warranty. Periodic inspections of tanks installed underground are recommended and may be required by the jurisdiction where installed. The container and valves of propane tanks to be buried underground should also be carefully checked for leaks immediately prior to installation in the ground. The licensed propane dealer or installer should make sure they follow all applicable federal, state or local regulatory requirements for protective coatings when they install a propane tank underground. The purchaser and installer are responsible for compliance with such federal, state and local regulations.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
appendices
An LP-gas regulator can double for a fairly effective small refrigerator. This is because the high-pressure gas, coming into the regulator, expands as it goes through the orifice. This expansion of gas creates refrigeration. Therefore, if there is moisture in the gas, small droplets may freeze as they are attempting to pass through the cold orifice. If the flow of gas is large enough and there is enough moisture in the fuel, the orifice of the regulator could well be blocked by ice, stopping the flow of gas. Freeze-ups can occur even though outside temperatures are above freezing. How does moisture get in the tank? ASME tanks are hydrostatically tested during fabrication, thereby introducing moisture to the tank. Vacuum pre-purging of tanks should eliminate most of this moisture and air containing moisture from the tank. That is why it is important that air (which will contain moisture) not be allowed into the tank when the vacuum is neutralized when first filling a vacuum pre-purged tank. The easiest way to cure this type of freeze-up is to keep as much moisture as possible from your fuel. Adding genuine absolute anhydrous methanol (99.85 pure) to your tanks when you first fill them is extra insurance to prevent freezeups from any moisture that may still be in the new tank. Methanol will lower the freezing point of water sufficiently to prevent freezing. When mounting the regulator, be sure the regulator outlet is higher than the service valve outlet.
If pigtails are “looped,” be sure the loop is upward, preventing moisture from collecting and freezing at the bottom of the loop. Many times regulators are blamed for freeze-ups when ice frozen in the pigtails is the cause. Use larger pigtails (3/8” OD hogtails have more than three times the cross-sectional area of the standard 1/4” pigtail). Twostage regulation helps prevent freeze-ups.
12 217
LP Container Requirements
SECTION
12
Purging LP-Gas Containers
Up to 2,000 Water Gallon Capacity — ASME & DOT Containers, Including Motor Fuel Containers. Purging and Moisture Removal Methanol Injection Chart All new containers (and in some cases used containers) – Suggested Amounts may contain water, air, or other contaminants, and it is essential that these be removed before filling the container 1 pint of methanol per 100 gallons of container capacity and placing it into service. Water vapor present in the gas 100# I.C.C. or D.0.T. cylinder add 1/8 pint or 2 fluid ounces vapor may cause regulator freeze-up at the inlet orifice and interrupt the gas service. Also, it may have an effect on 100 gallon container add 1 pint the ability of the odorant to meet the present standards, 250 gallon container add 2.5 pints as water can cause oxidation (rusting) on the inside of the container and result in “odorant fade.” Air in the container 500 gallon container add 5 pints will cause abnormally high pressure, with the result that 1,000 gallon container add 10 pints the pressure relief valve may open. Air in the system is also 2,000 gallon container add 20 pints likely to cause pilot flames to go out and result in a service call. Additionally, air in the container carries moisture, which can cause service problems. If a container is suspected of being depressurized or open to the atmosphere for a period of Alternate Purge Method Utilizing a Compressor time, it must be re-purged as if it were a new container. An LP-Gas compressor can be used to evacuate air in a To purge a container, the following steps should be taken: container to about 26” of mercury vacuum (2 PSI absolute pressure) when discharging to atmosphere. Hose suitable 1. Purging of containers should be performed in an for vacuum service would be used and all unused valves approved area (see NFPA #58). must be closed. Protective caps on both liquid fill and vapor 2. Determine if the container pressure is zero. Should equalization valves must be screwed on tightly to prevent air the container contain only air pressure, the air may from entering the container when vacuum is applied. When be vented directly to the atmosphere through the pressure has been reduced to 26” of mercury vacuum LP service valve. gas vapor can be introduced until the container has reached 3. If free water is present in the container, it should atmospheric pressure. Add methanol as suggested and the be drained. container is then ready to be filled with liquid LP-gas. 4. Pressurize the container to approximately 15 PSIG This method effectively removes water vapor after the water with LP-gas vapor. Never purge with liquid LP-gas; is drained and reduces air in the container to about 10 of the to do so will cause the moisture vapor to chill and volume at atmospheric pressure. No LP-gas is released to remain in the container. he atmosphere with this process. Evacuation time with the 5. Fully open the container service valve and vent to a 36 CFM compressor is approximately 15 minutes per 1,000 safe atmosphere. gallons of tank capacity. A CFM comporssor would take 6. Repeat fourth and fifth steps for a total of five purgings. approximately 30 minutes per 1,000 gallons of tank capacity. 7. The usual five purge pressurization methods requires Addendum the venting of about 15-18 gallons of LP-gas A. See NFPA-58 for more information on purging. per 1,000 gallons of container capacity. B. Consult Material Safety Data Sheet (MSDS - Methanol) 8. Add the suggested amount of methanol (see chart for additional information on care and handling of on the next column) and close valve. Methanol must methanol. be used in an approved and safe manner. Refer to the C. Consult NPGA Safety Bulletin on “Static Electricity” methanol MSDS for proper handling and warnings. 9. Repressurize the container with odorized LP-gas vapor to 15 PSIG. 10. The container is now ready to be filled with LP-gas. 11. Once filled, all fittings and tank openings should be checked for leaks using an approved leak detecting solution. 12. The container is now ready to be placed in service.
218
Gas Equipment Catalog
victormfg.com
SECTION
12
LP Container Requirements
Why You Should Use Cathodic Protection When Installing an Underground Propane Tank What is Corrosion? Corrosion of a steel tank is an electrical and chemical deterioration of the metal. It is sometimes called “electrolysis”. It causes pits which lead to holes on one place and not another. What is Cathodic Protection? Cathodic protection is a procedure used to protect an object from corrosion by making it a cathode. To make a tank a cathode, you have to attach an anode to it. Both have to be in an electrolyte such as earth or water. To protect a propane tank, you would attach at least one anode consisting of a bar of magnesium metal packed inside a cloth bag containing conductive earth backfill with a wire that is attached to the magnesium and the tank. Usually, 17 lbs. of magnesium and 28 Ibs. of earth backfill are used. The magnesium is a source of electrons for the iron atoms and it is from where d.c. current originates. As long as enough electrons flow from the magnesium through the wire and the connections on the tank, the tank will not corrode.
appendices
Why You Should Use Cathodic Protection When Installing an Underground Propane Tank First, what makes soil corrosive? Soil contains water and dissolved minerals responsible for damaging underground tanks. If you answer any of the following questions yes, then the tank will be corroded by the soil. Will it ever rain or snow there? Will the property owner plant grass, flowers, shrubs or trees over or near the tank? Will the grass, flowers, shrubs or trees be fertilized? Will ground moisture condense on the outside of the tank? Will water condense out of thin air on the surface of a cold container? Will the tank be near a sidewalk or down gradient from a driveway? Will the property owner ever throw salt or calcium chloride on the pavement to melt snow and ice? Will the tank ever be located near or downhill from livestock where salt and urea from animal waste will leach into the earth? Does the irrigation water contain salt or alkali salts? If a tank is set in a hole blasted from solid rock, does the rock contain pyrites, graphite or acidic rock that will be fractured and exposed to the oxidizing effect of air and water? If the tank is backfilled with sand or gravel from a sand or gravel company, will the sand contain minerals mined from river deposits not representative of the site in which the tank is to be buried? Will the tank be downhill from a septic tank leach field? Will the soil contain gypsum? Will the tank be set in shale or clay? Will groundwater be present? Will the tank be set on undisturbed earth and backfilled with loose backfill?
hold up under constant contact with mineralized moisture in the earth. Therefore, specialized coatings are needed to withstand the corrosive environment underground and provide a barrier between the steel surface and air, water and even electricity without deteriorating over time. The first line of defense against corrosion on an underground tank is good coating. Paint and coating companies make a variety of coatings for a vast array of applications. It is important to apply those that will hold up over time to constant attack by water, oxygen, carbon dioxide, mild acids, mechanical abrasion from rocks, earth movements, roots, bacteria and other biological organisms as they feed on organic compounds in them. They must be applied correctly or they will not adhere to the steel surface. Quality Steel applies a tough chemical and water resistant coating at the factory — a hard, baked on polyurethane finish. This factory applied coating is designed to be the final coating for the tank prior to its burial in the ground, provided the tank has an intact and continuous external coating at the time of burial. It is the installer’s responsibility to thoroughly inspect the tank to determine whether the factory applied protective coating is intact and continuous. If the coating is not found to be intact and continuous, then additional protection that is compatible with the manufacturer’s coating must be applied in a way to obtain this important result prior to burial. Coatings alone may not protect a buried tank against corrosion. After inspection and touchup the tanks can still get scratched, scraped and gouged during handling, setting, backfilling and settling. As a result the coating can have small imperfections here and there. Corrosion pitting rates are greater at these flaws, scratches and gaps in the coating than they are on completely bare tanks. Therefore, cathodic protection with anodes is needed to protect the steel wherever it is exposed. So, what can you do to provide cathodic protection for the underground propane tank? Anodes of magnesium are used to make the propane tank a cathode, thus improving its protection against possible corrosion. Magnesium anodes come in all shapes and sizes. The magnesium in a packaged anode can weigh from 1 to 50 Ibs. The most commonly used anode in the United States is a 17 Ib. anode. With 28 Ibs. of powdered backfill packed around the magnesium, a packaged 17 lbs.anode weighs about 45 Ibs.
Second, let’s consider coatings, the traditional way of preparing underground propane tanks for installation. All steel objects are painted to keep them
from rusting. The paint is a waterproof barrier between the steel surface and moisture in the air. Similarly, underground tanks need a waterproof coating to protect them from corrosive groundwater. Ordinary paint coatings do not
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
12 219
SECTION
12
LP Container Requirements Why You Should Use Cathodic Protection When Installing an Underground Propane Tank (continued) Tests on underground propane tanks have shown that smaller anodes can be effective at controlling corrosion on a well coated tank. Small anodes are used when the surface area or object to be protected is small. They cost less but cost the same as a large anode to install. However, it is important to remember that the life of a small anode is shorter than for a larger one. One of the more common questions asked is, “How long will an anode last?” Design engineers prefer to use larger anodes (and in greater numbers) because they last longer. The conditions and environment in which tanks and anodes are buried are so varied (as well as change with time) so that there is no definitive answer. Finally, however, when an anode is 85 consumed, it becomes too small to be effective. Because soil conditions change with time, one can hope for the best but plan for the worst. How do you install the anode? This is a very important question, for if the anode is not properly installed, it will not work. Schmoldt recommends the following: Install one 17 Ib. magnesium anode on a 500 gal. tank and two on a 1,000 gal. tank. The reason for the latter is to ensure that enough cathodic protection current is available for many years. Bury the anode at the end of the excavation where the earth is the wettest and the most conductive to the anode current. If water is available, pour 5 gal. on the anode to “jump start” the flow of current. Otherwise, the dry backfill will have to absorb moisture from the soil before current will flow. Roll out the anode wire to either the flat plate fitting on top of the tank or to the lifting ear. Wrap the wire around the fitting or ear so that the connection can not be pulled off should someone trip on the wire. Leave slack in the wire so that it is not pulled apart when the excavation is backfilled.
The wire can be attached to the tank by a thermite weld or with a nut and bolt. Whether you use a thermite weld or nut and bolt, remove 1” insulation on the copper wire and file off any paint or coating at the connection so that the metal wire is making contact to the tank for the weld or connection. If you use a thermite weld, the weld will not ignite the propane in the tank, but it could ignite propane in sufficient concentration in the excavation around the tank. Propane is heavier than air and will collect at your feet. If you smell propane, do not make the connection with the weld. So, how do you know a tank is protected? It doesn’t take long to check, and a check should be made at least annually. If the voltage of steel is -0.85 volts or greater, it is protected. It takes a voltmeter and a copper sulfate electrode to take the reading. It can be taken by your service person with a basic understanding of cathodic protection. If the reading is >-0.85 volts, you can assume that the tank is protected at the location where the reading was taken on the date it was taken. If the reading is <-0.85 volts, the anode installed on the tank either has been consumed, or the tank is connected to the house utilities without dielectric union, or the wire has been disconnected. Occasionally, there is a problem with the testing equipment or contact to the tank. The voltmeter’s contact with the tank can be made on any metal connected to the tank, including the gauging device, the regulator, the pressure relief valve or other fittings. The dome is not a good contact point. It is recommended that you take at least four readings around the tank.
Victor/F.w. Webb stocks burnham boilers.
220
Gas Equipment Catalog
victormfg.com
SECTION
12
LP Container Requirements
Cylinders Figure I.1 (a)*
Windows air conditioner (source of ignition) tIntake to direc vent appliance 5 ft. (min) (Note 1)
Central AC Compressor (source of ignition)
5 ft. (min) (Note 1)
10 ft. (min) (Note 2)
Cylinders not filled on site from bulk truck
3 ft. (min) (Note 3)
3 ft. (min) (Note 3) Crawl space opening, windows, or exhaust fan
Cylinders not filled on site
For SI units, 1 ft. = 0.3048 m Note 1: 5 ft. minimum front relief valve in any direction away from any exterior sources of ignition, openings into direct-vent appliances, or mechanical ventilation air intakes. Refer to 6.3.7(2). Note 2: If the cylinder is filled on site from a bulk truck, the filling connection and vent valve must be at least 10 ft. from any exterior source of ignition, openings into direct-vent appliances, ore mechanical ventilation air intakes. Refer to 6.3.10. Note 3: Refer to 6.3.7(1).
Aboveground ASME Containers Figure I.1 (b)*
Central AC Compressor (source of ignition) 10 ft. (min) (Note 1)
Intake to directvent appliance
125 Undel rw.c. ga
10 ft. (min) (Note 1) 5 ft. (min) (Note 2) 25 ft. (min) (Note 3)
Note 1: Regardless of its size, any ASME container filled on site must be located so that the filling connection and fixed maximum liquid level gauge are at least 10 ft. from any external source of ignition (e.g., open flame, window AC, compressor), intake to direct-vented gas appliance, or intake to a mechanical ventilation system. Refer to 6.3.10. Note 2: Refer to 6.3.9.
501
-20
00
gal
10 ft. (min) (Note 1)
125-
10 ft. (min) (Note 1) 500
Window air conditioner (source of ignition)
gal w .c.
10 ft. (min) (Note 1)
w.c .
25 ft. (min) (Note 3)
Note 3: This distance can be reduced to no less than 10 ft. for a single container of 1,200 gal. (4.5 m3) water capacity or less, provided such container is at least 25 ft. from any other LP-Gas container of more than 125 gal. (0.5 m3) water capacity. Refer to 6.3.3. * Figures are for illustrative purposes only; code shall govern.
TO ORDER, CALL: 800.243.9360 â&#x20AC;˘ CT: 860.722.2433 â&#x20AC;˘ FAX: 800.274.2004
221
appendices
Under 125 gal. w.c.
12
SECTION
12
LP Container Requirements Underground ASME Containers Figure I.1 (c)*
Window air conditioner ition (source of ign Intake to directvent appliance
10 ft. (min) (Note 1) 10 ft. (min) (Note 1) 10 ft. (min) Central AC Compressor (Note 1) (source of ignition) 2000 g al w or less .c.
10 ft. (min) (Note 2)
Crawl space opening, window, or exhaust fan
10 ft. (min) (Note 2)
For SI units, 1 ft. = 0.3048 m Note 1: The relief valve, filling connection, and fixed maximum liquid level gauge vent connection at the container must be at least 10 ft. from any exterior source of ignition, openings into direct-vent appliances, or mechanical ventilation air intakes. Refer to 6.3.10. Note 2: No part of an underground container can be less than 10 ft. from an important building or line of adjoining property that can be built upon. Refer to 6.3.4.2.
Victor/F.w. Webb stocks both lyco mechanical fittings and continential stab fittings for underground pe gas pipe.
* Figures are for illustrative purposes only; code shall govern.
222
Gas Equipment Catalog
victormfg.com
SECTION
12
Orifice Sizing and Properties of LP Gases
Table F.2 LP-Gases* (Btu per hour at sea level)
Propane Butane Btu per cubic foot = 2488 3280 Specific gravity = 1.50 2.01 Pressure at orifice, inches water column = 11 11 Orifice coefficient = 0.9 0.9 For altitudes above 2000 ft. first select the equivalent orifice size at sea level from Table F.4. Table F.2 LP-Gases (Btu per hour at sea level)
Propane 519 656 812 981 1169 1480 1708 2080 2629 3249 3581 4119 4678 5081 5495 6375 6934 7813 8320 8848 9955 10535 11125 11735 12367 13008 13660 14333 15026 17572 21939 24630 28769 32805
rifice O or Drill Size 51.000 50.000 49.000 48.000 47.000 46.000 45.000 44.000 43.000 42.000 41.000 40.000 39.000 38.000 37.000 36.000 35.000 34.000 33.000 32.000 31.000 30.000 29.000 28.000 27.000 26.000 25.000 24.000 23.000 22.000 21.000 20.000 19.000 18.000
Propane 36531 39842 43361 46983 50088 53296 54641 60229 64369 71095 74924 78029 80513 83721 87860 92207 98312 100175 103797 109385 117043 134119 150366 160301 168580 175617 181619 187828 192796 200350 205525 210699 223945 233466
Specific Gravity 0.45 0.50 0.55 0.60 0.65 0.70 0.75 0.80 0.85 0.90
Specific Multiplier 1.155 1.095 1.045 1.000 0.961 0.926 0.894 0.866 0.840 0.817
Gravity 0.95 1.00 1.05 1.10 1.15 1.20 1.25 1.30 1.35 1.40
Multiplier 0.795 0.775 0.756 0.739 0.722 0.707 0.693 0.679 0.667 0.655
* This section is an excerpt from the NFPA 54 National Fuel Gas Code — 1999 Edition
Approximate Properties LP-Gases*
Commercial Propane Vapor Pressure In PSI (Absolute Pressure At) 70°F 100°F 105°F 130°F Specific Gravity Of Liquid At 60°F Initial Boiling Point At 14.7 psia, °F Weight Per Gallon Of Liquid At 60°F, lb. Specific Heat Of Liquid, btu/lb. At 60°F Cubic Feet Of Vapor Per Gallon At 60°F Cubic Feet Of Vapor Per Pound At 60°F Specific Gravity of Vapor (Air = 1) At 60°F Ignition Temperature In Air, °F Maximum Flame Temperature In Air, °F Limits Of Flammability In Air Percent Of Vapor In Air–Gas Mixture: Lower Upper
145 218 233 315 0.504 –44 4.20 .630 36.38 8.66 1.50 920 – 1,120 3,595
2.15 9.60
appendices
rifice O or Drill Size 00.008 00.009 00.010 00.011 00.012 80.000 79.000 78.000 77.000 76.000 75.000 74.000 73.000 72.000 71.000 70.000 69.000 68.000 67.000 66.000 65.000 64.000 63.000 62.000 61.000 60.000 59.000 58.000 57.000 56.000 55.000 54.000 53.000 52.000
Table F.3 Multipliers for Utility Gases of Another Specific Gravity*
atent Heat Of Vaporization At Boiling Point L btu Per Pound 184 btu Per Gallon 773 Total Heating Values After Vaporization btu Per Cubic Foot btu Per Pound btu Per Gallon
2,488 21,548 91,502
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
223
12
SECTION
12
Orifice Sizing and Properties of LP Gases
Table F.1 Utility Gases*(or Natural Gas Specific Gravity .60) (cubic feet per hour at sea level)
Orifice Pressure at Orifice 3/4 Inches Water Column or Drill Size 3.5 4 7 80 0.52 0.55 0.73 79 0.59 0.64 0.84 78 0.76 0.78 1.04 77 0.95 0.99 1.31 76 1.13 1.21 1.61
Orifice Pressure at Orifice 3/4 Inches Water Column or Drill Size 3.5 4 7 35 34.95 36.86 48.78 34 35.05 37.50 49.75 33 36.08 38.79 51.46 32 38.30 40.94 54.26 31 40.85 43.83 58.01
75 74 73 72 71
1.25 1.44 1.63 1.77 1.97
1.34 1.55 1.76 1.90 2.06
1.79 2.05 2.32 2.52 2.73
30 29 28 27 26
46.87 52.33 55.92 58.83 61.27
50.39 56.19 59.50 63.17 65.86
66.72 74.45 79.50 83.59 87.24
70 69 68 67 66
2.22 2.43 2.72 2.91 3.09
2.39 2.61 2.93 3.12 3.32
3.16 3.47 3.88 4.13 4.39
25 24 23 22 21
63.58 65.67 67.07 70.08 71.83
68.22 70.58 72.20 75.21 77.14
90.36 93.47 94.55 99.60 102.29
65 64 63 62 61
3.39 3.68 3.92 4.08 4.34
3.72 4.14 4.19 4.39 4.66
4.84 5.23 5.55 5.81 6.15
20 19 18 17 16
73.68 77.98 81.57 84.82 88.77
79.08 83.69 87.56 91.10 95.40
104.75 110.67 116.03 120.33 126.78
60 59 58 57 56
4.55 4.76 5.03 5.23 6.13
4.89 5.11 5.39 5.63 6.58
6.47 6.78 7.13 7.44 8.73
15 14 13 12 11
92.02 94.40 97.11 101.41 103.62
98.84 100.78 104.32 108.52 111.31
131.07 133.22 138.60 143.97 147.20
55 54 53 52 51
7.68 8.59 10.04 11.46 12.77
8.22 9.23 10.80 12.31 13.69
10.85 12.25 14.29 16.34 18.16
10 9 8 7 6
106.16 109.07 112.20 114.40 117.88
114.21 117.11 120.65 123.01 126.78
151.50 154.71 160.08 163.31 167.51
50 49 48 47 46
13.92 15.20 16.36 17.52 18.57
14.94 16.28 17.62 18.80 19.98
19.77 21.60 23.31 24.93 26.43
5 4 3 2 1
119.97 123.93 128.79 138.76 147.26
128.93 133.22 137.52 148.61 158.25
170.82 176.18 182.64 197.66 209.48
45 44 43 42 41
19.15 21.01 22.39 24.95 25.98
20.52 22.57 24.18 26.50 28.15
27.18 29.87 32.02 35.24 37.17
40 39 38 37 36
27.03 28.20 29.25 30.63 32.14
29.23 30.20 31.38 32.99 34.59
38.79 39.97 41.58 43.62 45.77
For SI units, 1 Btu/hr = 0.293 W; 1 ft3 = 0.028 m3; 1 ft = 0.305 m; 1 in. water column = 249 pa. Notes: 1. Specific Gravity = 0.60; orifice coefficient = 0.90. 2. For utility gases of another specific gravity, select multiplier from Table F.3. For altitudes above 2000 ft, first select the equivalent orifice size at sea level from Table F.4.
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code â&#x20AC;&#x201D; 2001 Edition
224
Gas Equipment Catalog
victormfg.com
SECTION
12 Liquid Volume Tables and Temperature Correction Factors
Appendix F Liquid Volume Tables, Computations and Graphs This appendix is not a part of the requirements of this NFPA document but is included for informational purposes only.
F.1 Scope.
F.1.1 Application. This appendix explains the basis
for Table 4.4.2.1, includes the LP-Gas liquid volume temperature correction table, Table F.3.3, and describes its use. It also explains the methods of making liquid volume computations to determine the maximum permissible LP-Gas content of containers in accordance with Tables 4.4.2.2(a), (b), and (c).
F.2 Basis for Determination of LP-Gas Container Capacity. The basis for determination of the maximum permitted filling limits shown in Table 4.4.2.1 is the maximum safe quantity that will assure that the container will not become liquid full when the liquid is at the highest anticipated temperature. F.2.1 For portable containers built to DOT specifications and other aboveground containers with water capacities of 1200 gal (4.5 m3) or less, this temperature is assumed to be 130°F (54°C). F.2.2 For other aboveground uninsulated containers with water capacities in excess of 1200 gal (4.5 m3), including those built to DOT portable or cargo tank specifications, this temperature is assumed to be 115°F (46°C). F.2.3 For all containers installed under ground, this temperature is assumed to be 105°F (41°C).
(2) If the container is not equipped with a well, but is essentially empty of liquid prior to loading, the temperature of the liquid in the container from which liquid is being withdrawn can be used. Otherwise, a thermometer can be inserted in a thermometer well or other temperature-sensing device installed in the loading line at a point close to the container being loaded. Read temperatures at intervals during trans fer and averaging. [See F.3.2(c).] (3) A suitable liquid should be used in thermometer wells to obtain an efficient heat transfer from the LP Gas liquid in the container to the thermometer bulb. The liquid used should be noncorrosive and should not freeze at the tem-peratures to which it will be subjected. Water should not be used. F.3.3 The volume observed or measured is corrected to 60....F (16....C) by use of Table F.3.3. The column headings, across the top of the tabulation, list the range of specific gravities for the LP-Gases. Specific gravities are shown from 0.500 to 0.590 by 0.010 increments, except that special columns are inserted for chemically pure propane, isobutane, and normal butane. To obtain a correction factor, follow down the column for the specific gravity of the particular LP-Gas to the factor corresponding with the liquid temperature. Interpolation between the specific gravities and temperatures shown can be used if necessary.
appendices
F.3 Liquid Volume Correction Table. Correction of observed volume to standard temperature condition (60°F and equilibrium pressure). F.3.1 The volume of a given quantity of LP-Gas liquid in a container is directly related to its temperature, expanding as temperature increases and contracting as temperature decreases. Standard conditions, often used for weights and measures purposes and, in some cases, to comply with safety regulations, specify correction of the observed volume to what it would be at 60°F (16°C). F.3.2 To correct the observed volume to 60°F (16°C), the specific gravity of LP-Gas at 60°F (16°C) in relation to water at 60°F (16°C) (usually referred to as “60°/60°F”) and its average temperature must be known. The specific gravity normally appears on the shipping papers. The average liquid temperature can be obtained as follows: (1) Insert a thermometer in a thermometer well in the container into which the liquid has been transferred, and read the temperature after the completion of the transfer. [see F.3.2(c) for proper use of a thermometer].
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
225
12
SECTION
Liquid Volume Tables and Temperature Correction Factors 12 Liquid Volume Correction Factors* Specific Gravities at 60°F/60°F Observed Temp., Degrees Propane Fahrenheit 0.5079 –50 1.155 –45 1.148 –40 1.142 –35 1.135 –30 1.129 –25 1.122 –20 1.115 –15 1.109 –10 1.102 –5 1.094 0 1.088 2 1.086 4 1.083 6 1.080 8 1.078 10 1.075 12 1.072 14 1.070
Observed Temp., Degrees Propane Fahrenheit 0.5079 16 1.067 18 1.065 20 1.062 22 1.059 24 1.056 26 1.053 28 1.050 30 1.047 32 1.044 34 1.041 36 1.038 38 1.035 40 1.032 42 1.029 44 1.026 42 1.029 44 1.026 46 1.022
Observed Temp., Degrees Propane Fahrenheit 0.5079 48 1.019 50 1.016 52 1.013 54 1.010 56 1.007 58 1.003 60 1.000 62 0.997 64 0.993 66 0.990 68 0.986 70 0.983 72 0.980 74 0.976 76 0.973 78 0.970 80 0.967 82 0.963
Observed Temp., Degrees Propane Fahrenheit 0.5079 84 0.959 86 0.956 88 0.952 90 0.949 92 0.945 94 0.941 96 0.938 98 0.934 100 0.930 105 0.920 110 0.911 115 0.902 120 0.892 125 0.881 130 0.871 135 0.861 140 0.850
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
226
Gas Equipment Catalog
victormfg.com
SECTION
12
Vaporizer and Electrical Requirements
3.6.3 Installation of Direct-Fired Vaporizers
3.6.3.1 Direct-fired vaporizers shall comply with 2.5.5.2
and shall be installed as follows.
3.6.3.2 Where a direct-fired vaporizer is installed in
a separate structure, the separate structure shall be constructed in accordance with Chapter 7. 3.6.3.3 The housing for direct-fired vaporizers shall not have any drains to a sewer or a sump pit that is shared with any other structure or to a sewer. Pressure relief valve discharges on direct-fired vaporizers shall be piped to a point outside the structure or building. 3.6.3.4 Direct-fired vaporizers shall be connected to the liquid space or to the liquid or vapor space of the container. A manually operated shutoff valve shall be installed in each connection of the container supplying the vaporizer. 3.6.3.5 Direct-fired vaporizers of any capacity shall be located in accordance with Table 3.6.3.5. Table 3.6.3.5 Minimum Separation Distances Between Direct-Fired Vaporizers and Exposures
3.7.2 Electrical Equipment 3.7.2.1 Electrical equipment and wiring shall be of a type
specified by, and installed in accordance with, NFPA 70, National Electrical Code®, for ordinary locations. Exception: Fixed electrical equipment in classified areas shall comply with 3.7.2.2. 3.7.2.2* Fixed electrical equipment and wiring installed within classified areas specified in Table 3.7.2.2 shall comply with Table 3.7.2.2 and shall be installed in accordance with NFPA 70, National Electrical Code. The provision shall apply to vehicle fuel operations. (See Figure 3.7.2.2.) Exception: This provision shall not apply to fixed electrical equipment at residential or commercial installations of LP-Gas systems or to systems covered by Section 3.8.
FIGURE 3.7.2.2 Extent of electrically classified area. (See Table 3.7.2.2.) 3.7.2.3 Fired vaporizers, calorimeters with open flames, and other areas where open flames are present either intermittently or constantly shall not be considered electrically classified areas.
Minimum Distance Required Exposure ft m Container 10 3.0 Container Shutoff Valves 15 4.6 Point Of Transfer 15 4.6 Nearest Important Buildings Or Group Of 25 7.6 Buildings Or Line Of Adjoining Property That Can Be Built Nearest Chapter 7 Building Or Room 10 3.0 Housing Gas–Air Mixer Cabinet Housing Gas–Air Mixer Outdoors 0 0 Note: Do not apply distances to the building in which a direct-fired vaporizer is installed.
appendices
3.6.6. Installation of Waterbath Vaporizers. Waterbath vaporizers shall comply with 2.5.5.3 and shall be installed as follows: 3.6.6.1 If a waterbath vaporizer is electrically heated and all electrical equipment is suitable for Class 1, Group D locations, the unit shall be treated as indirect-fired and shall be installed in accordance with 3.6.2. 3.6.6.2 All other waterbath vaporizers shall be treated as direct-fired vaporizers and shall be installed in accordance with 3.6.3. 3.6.7 Installation of Electric Vaporizers. Electric vaporizers, whether direct immersion or indirect immersion, shall be treated as indirect-fired and shall be installed in accordance with 3.6.2.
12
* This section is an excerpt from the NFPA 58 Liquified Petroleum Gas Code — 2001 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
227
Suggested Method of Leak Checking
SECTION
12
D. Suggested Method for Checking for Leakage* This appendix is not a part of the requirements of this code but is included for informational purposes only. D.1 Use of Lights. Artificial illumination used in connection with a search for gas leakage should be restricted to battery-operated flashlights (preferably of the safety type) or approved safety lamps. In searching for leaks, electric switches should not be operated. If electric lights are already turned on, they should not be turned off. D.2 Testing for Leakage Using the Gas Meter. Immediately prior to the test, it should be determined that the meter is in operating condition and has not been bypassed. Checking for leakage can be done by carefully watching the test dial of the meter to determine whether gas is passing through the meter. To assist in observing any movement of the test hand, wet a small piece of paper and paste its edge directly over the centerline of the hand as soon as the gas is turned on. This observation should be made with the test hand on the upstroke. Table D.2 can be used for determining the length of observation time. Table D.2 Test Observation Times for Various Meter Dials Dial Styles (ft3) 1/4 1/2 1 2 5 10
Test Time (minutes) 5 5 7 10 20 30
For SI units, 1 ft 3 = 0.028 m3.
In case careful observation of the test hand for a sufficient length of time reveals no movement, the piping should be purged and a small gas burner turned on and lighted, and the hand of the test dial again observed. If the dial hand moves (as it should), it will show that the meter is operating properly. If the test hand does not move or register flow of gas through the meter to the small burner, the meter is defective and the gas should be shut off and the serving gas supplier notified.
(1) (2)
appliance regulators, and control valves in the system. Accordingly, each individual equipment shutoff valve should be supplying pressure to its appliance for the leak check. This check will prove the integrity of the 100 percent pilot shutoff of each gas valve so equipped, so the manual gas cock of each gas valve incorporating a 100 percent pilot shutoff should be in the on position. Pilots not incorporating a 100 percent pilot shutoff valve and all manual gas valves not incorporating safety shutoff systems are to be placed in the off position prior to leak checking, by using one of the following methods: By inserting a pressure gauge between the container gas shutoff valve and the first regulator in the system, admitting full container pressure to the system and then closing the container shutoff valve. Enough gas should then be released from the system to lower the pressure gauge reading by 10 psi (69 kPa). The system should then be allowed to stand for 3 minutes without showing an increase or a decrease in the pressure gauge reading. For systems serving appliances that receive gas at pressures of 1/2 psi (3.5 kPa) or less, by inserting a water manometer or pressure gauge into the system downstream of the final system regulator, pressurizing the system with either fuel gas or air to a test pressure of 9 in. ± 1/2 in. (2.2 kPa ± 0.1 kPa) water column, and observing the device for a pressure change. If fuel gas is used as a pressure source, it is necessary to pressurize the system to full operating pressure, close the container service valve, and then release enough gas from the system through a range burner valve or other suitable means to drop the system pressure to 9 in. ± 1/2 in. (2.2 kPa ± 0.1 kPa) water column. This ensures that all regulators in the system are unlocked and that a leak anywhere in the system is communicated to the gauging device. The gauging device should indicate no loss or gain of pressure for a period of 3 minutes.
D.3 Testing for Leakage Not Using a Meter.
This test can be done by one of the following methods: (a) For Any Gas System. To an appropriate checkpoint, attach a manometer or pressure gauge between the inlet to the piping system and the first regulator in the piping system, and momentarily turn on the gas supply and observe the gauging device for pressure drop with the gas supply shut off. No discernible drop in pressure should occur during a period of 3 minutes. (b) For Gas Systems Using Undiluted Liquefied Petroleum Gas. System Preparation for Propane. A leak check performed on an LP-Gas system being placed back in service should include all regulators, including
228
Gas Equipment Catalog
victormfg.com
SECTION
12
Suggested Method of Leak Checking
D. Suggested Method for Checking for Leakage 3.2.15.3 Metallic pipe joints shall be permitted to be threaded, flanged, welded, or brazed using pipe and fittings that comply with 2.4.2 and 2.4.4 as follows. (a) Metallic threaded and welded pipe joints shall be in accordance with Table 3.2.15.3(a).
Table 3.2.15.3(a) Types of Metallic Pipe Joints in LP-Gas Service Service Schedule 40 Liquid Welded Vapor, £125 psig Threaded or (£0.9 MPag) Welded Vapor, >125 psig Welded (>0.9 MPag)
Schedule 80 Threaded or Welded Threaded or Welded Threaded or Welded
(b) Fittings and flanges shall be designed for a working pressure equal to or greater than the required working pressure of the service for which they are used. (c) Brazed joints shall be made with a brazing material having a melting point exceeding 1000°F (538°C). (d) Gaskets used to retain LP-Gas in flanged connections in piping shall be resistant to the action of LP-Gas. They shall be made of metal or material confined in metal having a melting point over 1500°F (816°C) or shall be protected against fire exposure. When a flange is opened, the gasket shall be replaced. Exception No. 1: Aluminum O-rings and spiral wound metal gaskets shall be permitted. Exception No. 2: Nonmetallic gaskets used in insulating fittings shall be permitted.
3.2.15.4 Metallic tubing joints shall be flared or brazed using tubing and fittings in accordance with 2.4.3 and 2.4.4. 3.2.15.5 Piping in systems shall be run as directly as is practical from one point to another, with as few fittings as practical.
Where condensation of vapor can occur, piping shall be sloped back to the container or means shall be provided for revaporizing the condensate.
(continued)
3.2.15.8 Buried metallic pipe and tubing shall be installed underground with a minimum 18 in. (460 mm) of cover. The cover shall be permitted to be reduced to 12 in. (300 mm) if external damage to the pipe or tubing is not likely to result. If a minimum 12 in. (300 mm) of cover cannot be maintained, the piping shall be installed in conduit or shall be bridged (shielded). Where underground piping is beneath driveways, roads, or streets, possible damage by vehicles shall be taken into account. 3.2.15.9 Underground metallic piping shall be protected against corrosion as warranted by soil conditions (see 3.2.24). 3.2.15.10 LP-Gas piping shall not be used as a grounding electrode.
3.2.16 Polyethylene Pipe, Tubing, and Fittings. 3.2.16.1 Polyethylene pipe, tubing and fittings shall be installed outdoors underground only. 3.2.16.2 Polyethylene pipe and tubing shall be buried as follows: (1) With a minimum 18 in. (460 mm) of cover (2) With a minimum of 12 in. (300 mm) of cover if external damage to the pipe or tubing is not likely to result (3) If a minimum 12 in. (300 mm) of cover cannot be provided, with piping installed in conduit or bridged (shielded). 3.2.16.3 Assembled anodeless risers shall be used to terminate underground polyethylene piping systems above ground. The horizontal portion of risers shall be buried at least 12 in. (300mm) below grade and the casing material used for the risers shall be protected against corrosion in accordance with 3.2.24. 3.2.16.4 Either the aboveground portion of the riser casing shall be provided with a plastic sleeve inside the riser casing or the pipe or tubing shall be centered in the riser casing. 3.2.16.5 Factory-assembled risers shall be sealed and leak tested by the manufacturer.
appendices
3.2.15.6 Piping systems including interconnecting of permanently installed containers shall compensate for expansion, contraction, jarring and vibration, and for settling. Using flexible connectors complying with 2.4.6 shall be permitted. The use of nonmetallic pipe, tubing, or hose for permanently interconnecting such containers shall be prohibited. 3.2.15.7 Aboveground piping shall be supported and
protected against physical damage by vehicles. The portion of aboveground piping in contact with a support or a corrosion-causing substance shall be protected against corrosion.
12 TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
229
Suggested Method of Leak Checking D. Suggested Method for Checking for Leakage*
SECTION
12
(continued)
3.2.16.6 Field-assembled risers shall be supplied only in kit form with all necessary hardware for installation. Field-assembled risers shall comply with the following: (1) Be design certified. (2) Be sealed and pressure tested by the installer. (3) Be assembled and installed in accordance with the riser manufacturerâ&#x20AC;&#x2122;s instructions. 3.2.16.7 The casing of the riser shall be constructed of one of the following materials: (1) ASTM A 53, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless, Schedule 40 steel pipe. (2) ASTM A 513, Standard Specification for Elec tric-Resistance-Welded Carbon and Alloy Steel Mechanical Tubing, mechanical steel tubing with a minimum wall thickness of 0.073in. (1.9 mm). (3) A flexible metal tubing with a minimum crush strength of 1000 lb (453.6 kg) and a tensile strength of 300 lb (136 kg) including the tran sition connection as tested by the manufacturer. 3.2.16.8* Polyethylene piping shall be installed so as to minimize thrust forces caused by contraction or expansion of the piping or by anticipated external or internal loading. The pipeline shall be designed and installed so that each joint will sustain these forces. 3.2.16.9 An electrically continuous corrosion-resistant tracer wire (minimum AWG 14) or tape shall be buried with the polyethylene pipe to facilitate locating. One end shall be brought aboveground at a building wall or riser. The wire or tape shall not be in direct contact with the polyethylene pipe. 3.2.16.10 Polyethylene piping that is installed in a vault or any other belowground enclosure shall be completely encased in gastight metal pipe and fittings that are protected from corrosion.
* This section is an excerpt from the NFPA 54 National Fuel Gas Code â&#x20AC;&#x201D; 1999 Edition
230
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Table N-1 Low Pressure (Standard)*
Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 6-7 inches W.C.; Pressure Drop: 0.5 inch W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 15 19 25 31 37 46 62
5 63 134 288 546 1109 1790 4142
10 44 95 206 383 789 1261 2934
15 35 77 169 310 646 1027 2398
20 31 67 147 269 561 888 2078
25 27 60 132 240 503 793 1860
30 25 55 121 218 460 723 1698
40 21 47 105 188 399 625 1472
50 19 42 94 168 358 559 1317
60 17 38 86 153 327 509 1203
70 16 36 80 141 303 471 1114
80 15 33 75 132 284 440 1042
90 14 32 71 125 268 415 983
100 13 30 67 118 254 393 933
150 10 23 55 94 208 320 762
200 9 21 48 82 181 277 661
250 8 19 43 74 162 247 591
300 7 17 39 67 148 226 540
Table N-2A Low Pressure (Canada & USA 1 inch drop)*
Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 6-7 inches W.C.; Pressure Drop: 1 inch W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 15 19 25 31 37 46 62
5 82 182 403 734 1558 2541 5848
10 58 131 288 518 1109 1790 4142
15 48 108 237 423 908 1458 3386
20 42 94 206 366 789 1261 2934
25 37 85 185 327 707 1126 2626
30 34 78 169 299 646 1027 2398
40 30 68 147 259 561 888 2078
50 27 61 132 231 503 793 1860
60 24 56 121 211 460 723 1698
70 23 52 112 195 426 669 1573
80 21 48 105 183 399 625 1472
90 20 46 99 172 377 589 1388
100 19 44 94 163 358 559 1317
150 15 36 77 133 293 455 1076
200 13 31 67 115 254 393 933
250 12 28 60 103 228 351 835
300 11 26 55 94 208 320 762
Table N-2B Low Pressure (Canada & USA 2 inch drop)*
Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 7-8 inches W.C.; Pressure Drop: 2 inches W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) EHD 15 19 25 31 37 46 62
5 115 254 564 1038 2191 3607 8257
10 82 182 403 734 1558 2541 5848
15 67 150 331 599 1277 2070 4780
20 58 131 288 518 1109 1790 4142
25 52 118 258 463 994 1599 3707
30 48 108 237 423 908 1458 3386
40 42 94 206 366 789 1261 2934
50 37 85 185 327 707 1126 2626
60 34 78 169 299 646 1027 2398
70 32 72 157 276 599 950 2221
80 30 68 147 259 561 888 2078
90 28 64 139 244 529 837 1960
100 27 61 132 231 503 793 1860
150 22 50 108 189 412 646 1520
200 19 44 94 163 358 559 1317
250 17 39 84 146 320 499 1179
300 15 36 77 133 293 455 1076
* Tables above include losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends and/or fittings shall be increased by an equivalent length of tubing to the following equation: L = 1.3n where L is additional length of tubing and n is the number of additonal fittings and/or bends. EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity; This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
231
appendices
Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
12
SECTION
12
Gas Line Sizing Table N-3 Regulator Outlet (8 inches W.C.)*
Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 8 inches W.C.; Pressure Drop: 3 inches W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 5 15 160 19 327 25 687 31 1365 37 2673 46 4428 62 10103
10 112 231 491 958 1902 3119 7156
15 90 189 403 778 1558 2541 5848
20 78 164 351 672 1353 2197 5069
25 69 147 315 599 1213 1963 4536
30 63 134 288 546 1109 1790 4142
40 54 116 250 471 963 1548 3590
50 48 104 225 421 863 1383 3213
60 44 95 206 383 789 1261 2934
70 41 88 191 355 731 1166 2717
80 38 82 179 331 685 1090 2543
90 36 77 169 311 646 1027 2398
100 34 73 160 295 614 974 2276
150 27 60 132 240 503 793 1860
200 23 52 115 207 436 686 1612
250 21 46 103 184 391 613 1442
300 19 42 94 168 358 559 1317
Table N-3A 3P (11 inches W.C.)*
Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas Gas Pressure: 11 inches W.C.; Pressure Drop: 5 inches W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 5 15 207 19 419 25 878 31 1766 37 3436 46 5732 62 13026
10 144 297 627 1237 2444 4038 9227
15 116 242 515 1005 2003 3290 7541
20 100 210 448 867 1739 2844 6535
25 89 188 402 773 1558 2541 5858
30 81 172 368 704 1425 2317 5341
40 70 149 320 607 1237 2004 4629
50 62 133 287 542 1109 1790 4142
60 56 122 263 493 1014 1632 3783
70 52 113 244 456 940 1510 3504
80 48 105 228 425 880 1411 3279
90 45 99 216 400 831 1330 3092
100 43 94 205 379 789 1261 2934
150 35 77 168 308 646 1027 2398
200 30 67 146 266 561 888 2078
250 26 60 131 237 503 793 1860
300 24 54 120 216 460 723 1698
Table N-4 Medium Pressure*
Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: .5 psi (12-14 inches W.C.); Pressure Drop: 6 inch W.C. (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 5 10 15 229 160 19 461 327 25 962 687 31 1946 1365 37 3757 2673 46 6286 4428 62 14263 10103
15 130 267 564 1110 2191 3607 8257
20 112 231 491 958 1902 3119 7156
25 99 207 441 855 1704 2786 6404
30 90 189 403 778 1558 2541 5848
40 78 164 351 672 1353 2197 5069
50 69 147 315 599 1213 1963 4536
60 63 134 288 546 1109 1790 4142
70 58 124 267 505 1028 1656 3837
80 54 116 250 471 963 1548 3590
90 51 109 237 444 908 1458 3386
100 48 104 225 421 863 1383 3213
150 39 85 185 342 707 1126 2626
200 34 73 160 295 614 974 2276
250 30 66 144 263 550 870 2036
300 27 60 132 240 503 793 1860
* Tables above include losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends and/or fittings shall be increased by an equivalent length of tubing to the following equation: L = 1.3n where L is additional length of tubing and n is the number of additonal fittings and/or bends. EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity; This number is used to compare individual sizes between different manufacturers. The higher the EHD number the greater flow capacity of the piping.
232
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Table N-5 Elevated Pressure (2 psi)*
Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 2 psi; Pressure Drop: 1 psi (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 15 19 25 31 37 46 62
10 353 700 1444 2986 5670 9599 21637
25 220 444 926 1869 3615 6041 13715
30 200 405 847 1703 3305 5509 12526
40 172 351 737 1470 2870 4763 10855
50 154 314 661 1311 2572 4255 9715
75 124 257 543 1066 2108 3467 7940
80 120 249 527 1031 2042 3355 7689
100 107 222 473 920 1830 2997 6881
150 87 182 388 748 1499 2442 5624
200 75 157 338 645 1302 2111 4874
250 67 141 303 576 1167 1886 4362
300 61 129 277 525 1067 1720 3983
400 52 111 241 453 926 1487 3452
500 46 100 216 404 830 1329 3089
Table N-5A Elevated Pressure (2 psi)*
Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 2 psi; Pressure Drop: 1.5 psi (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 15 19 25 31 37 46 62
10 438 855 1761 3687 6919 11782 26473
25 271 542 1129 2304 4412 7415 16781
30 247 495 1033 2098 4034 6762 15326
40 212 429 899 1810 3502 5847 13282
50 189 384 806 1614 3139 5223 11886
75 153 314 662 1311 2572 4255 9715
80 148 304 642 1268 2492 4119 9408
100 131 272 576 1131 2233 3679 8419
150 106 222 473 919 1830 2997 6881
200 91 193 411 793 1589 2592 5963
250 81 172 369 707 1424 2315 5337
300 74 157 338 644 1302 2111 4874
400 64 136 294 555 1130 1826 4224
500 56 122 264 495 1013 1631 3780
Table N-6 Elevated Pressure (5 psi)*
Maximum Capacity of OmegaFlex TracPipe in Cubic Feet per Hour Natural Gas (1,000 BTU approximate) Gas Pressure: 5 psi; Pressure Drop: 3.5 psi (based on a 0.6 Specific Gravity Gas) Tubing Length (Feet) EHD 15 19 25 31 37 46 62
10 672 1304 2650 5659 10489 18080 40353
25 420 827 1699 3543 6688 11378 25580
30 382 755 1556 3228 6116 10377 23361
40 329 654 1353 2786 5310 8972 20246
50 293 586 1214 2486 4759 8015 18119
75 238 479 998 2021 3899 6530 14809
80 230 463 967 1955 3778 6320 14341
100 205 415 868 1744 3386 5646 12834
150 166 339 713 1418 2774 4600 10489
200 143 294 620 1224 2409 3977 9090
250 128 263 556 1092 2159 3553 8135
300 116 240 509 955 1974 3240 7430
400 100 208 443 858 1714 2802 6439
500 89 186 397 766 1536 2503 5762
* Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds 3/4 PSI (based on 8 inch outlet pressure, do not use this chart. Pressure drops across a regulator vary with flow rate. FGP-REG-5 has a 1 PSI pressure drop at a flow of 673 cubic feet per hour. CAUTION: Capacities shown in table may exceed maximum capacity for a selected regulator. Table does not include effect of pressure drop across the line regulator.
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
233
appendices
Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
12
SECTION
12
Gas Line Sizing Table P-1 Propane Low Pressure (Standard)*
Maximum Capacity of OmegaFlex TracPipe in Thousands of BTU per Hour Propane Gas Gas Pressure: 11 inches W.C.; Pressure Drop: 0.5 W.C. (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 15 19 25 31 37 46 62
5 99 211 456 863 1753 2830 6547
10 69 150 325 605 1247 1993 4638
15 55 121 267 490 1021 1623 3791
20 49 106 232 425 887 1404 3285
25 42 94 209 379 795 1254 2940
30 39 87 191 344 727 1143 2684
40 33 74 166 297 631 988 2327
50 30 66 149 265 566 884 2082
60 26 60 136 241 517 805 1902
70 25 57 126 222 479 745 1761
80 23 52 118 208 449 696 1647
90 22 50 112 197 424 656 1554
100 20 47 106 186 402 621 1475
150 15 36 87 143 329 506 1205
200 14 33 76 129 286 438 1045
250 12 30 68 117 256 390 934
300 11 26 62 107 234 357 854
Table P-2 Propane Medium Pressure*
Maximum Capacity of OmegaFlex TracPipe in Thousdands of BTU per Hour Propane Gas Gas Pressure: .5 psi (12-14 in. W.C.); Pressure Drop: 2.5 in. W.C. (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 5 10 15 222 159 19 491 353 25 1094 782 31 2512 1863 37 3863 2749 46 6383 4496 62 14586 10330
15 131 290 642 1720 2253 3663 8443
20 114 254 559 1343 1955 3168 7317
25 102 228 501 1106 1753 2830 6547
30 93 209 459 976 1603 2580 5980
40 81 182 399 883 1391 2230 5183
50 73 164 358 825 1247 1993 4638
60 67 150 328 771 1140 1818 4236
70 62 140 304 719 1056 1682 3923
80 58 131 285 673 990 1571 3671
90 55 124 269 632 934 1481 3462
100 52 118 256 596 887 1404 3285
150 43 97 210 470 727 1143 2684
200 37 85 183 398 631 988 2327
250 33 76 164 352 566 884 2082
300 30 70 136 320 517 805 1902
Table P-3 Propane Elevated Pressure (2 psi)*
Maximum Capacity of OmegaFlex TracPipe in thousands of BTU per Hour Propane Gas Gas Pressure: 2 psi; Pressure Drop: 1 psi (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 15 19 25 31 37 46 62
10 558 1106 2282 4720 8963 15174 34203
25 347 701 1464 2954 5714 9549 21680
30 316 640 1340 2692 5224 8708 19801
40 271 554 1165 2323 4537 7529 17159
50 243 496 1046 2072 4066 6726 15357
75 196 406 859 1685 3332 5480 12551
80 189 393 833 1629 3228 5303 12154
100 169 350 748 1454 2893 4738 10877
150 137 287 614 1182 2370 3860 8890
200 118 248 534 1019 2058 3337 7705
250 105 222 479 910 1845 2981 6895
300 96 203 439 829 1687 2719 6296
400 82 175 381 716 1464 2351 5457
500 72 158 342 638 1312 2101 4883
* Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds 3/4 PSI (based on 8 inch outlet pressure, do not use this chart. Pressure drops across a regulator vary with flow rate. FGP-REG-5 has a 1 PSI pressure drop at a flow of 673 cubic feet per hour. CAUTION: Capacities shown in table may exceed maximum capacity for a selected regulator. Table does not include effect of pressure drop across the line regulator.
234
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Table P-3A Propane Elevated Pressure (2 psi)*
Maximum Capacity of OmegaFlex TracPipe in Thousands of BTU per Hour Propane Gas Gas Pressure: 2 psi; Pressure Drop: 1.5 psi (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 15 19 25 31 37 46 62
10 817 1588 3237 6838 10937 18624 41847
25 525 1041 2147 4436 6974 11721 26527
30 481 957 1978 4070 6377 10689 24227
40 419 839 1739 3553 5536 9243 20996
50 376 757 1574 3198 4962 8256 18789
75 310 628 1312 2641 4066 6726 15357
80 300 609 1275 2561 3939 6511 14872
100 269 550 1153 2305 3530 5816 13308
150 222 456 962 1903 2893 4738 10877
200 193 399 845 1661 2512 4097 9426
250 173 360 765 1495 2251 3659 8436
300 159 331 705 1372 2058 3337 7705
400 138 290 619 1198 1786 2886 6677
500 124 262 560 1078 1601 2578 5975
400 158 328 700 1356 2709 4429 10178
500 140 294 629 1210 2428 3957 9108
Table P-4 Propane Elevated Pressure (5 psi)*
Maximum Capacity of OmegaFlex TracPipe in Thousands of BTU per Hour Propane Gas Gas Pressure: 5 psi; Pressure Drop: 3.5 psi (based on a 1.52 Specific Gravity Gas) Tubing Length (Feet) Size 3/8” 1/2” 3/4” 1” 11/4” 11/2” 2”
EHD 15 19 25 31 37 46 62
10 1065 2061 4189 8945 16581 28580 63788
25 664 1307 2686 5600 10572 17986 40436
30 603 1193 2459 5102 9668 16403 36928
40 520 1033 2139 4404 8394 14183 32004
50 463 926 1920 3929 7523 12670 28642
75 376 757 1577 3194 6163 10322 23409
80 363 731 1529 3090 5972 9990 22670
100 324 656 1310 2756 5352 8925 20287
150 262 535 1127 2241 4796 7271 16581
200 226 464 980 1934 4385 6287 14369
250 202 416 880 1726 3808 5616 12859
300 183 379 805 1572 3120 5122 11745
* Table does not include effect of pressure drop across the line regulator. If regulator loss exceeds 3/4 PSI (based on 8 inch outlet pressure, do not use this chart. Pressure drops across a regulator vary with flow rate. FGP-REG-5 has a 1 PSI pressure drop at a flow of 673 cubic feet per hour. CAUTION: Capacities shown in table may exceed maximum capacity for a selected regulator. Table does not include effect of pressure drop across the line regulator.
appendices
Victor/F.w. Webb stocks buderus boilers. TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
12 235
SECTION
12
Gas Line Sizing Propane 10#
Table 6.3 (a) Schedule 40 Metallic Pipe SPECIAL USE: Pipe Sizing Between First Stage (High Pressure Regulator) and Second Stage (Low Pressure Regulator) Gas Inlet Pressure Pressure Drop Specific Gravity
Undiluted Propane 10.0 psi 1.0 psi 1.50 Pipe Size (inches)
Nominal Inside
1/2
3/4
1
11/4
11/2
2
21/2
3
4
Actual
0.622
0.824
1.049
1.380
1.610
2.067
2.469
3.068
4.026
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000
3,320 2,280 1,830 1,570 1,390 1,260 1,160 1,080 1,010 956 848 768 706 657 582 528 486 452 424 400 380 363 347 334 321 310 300 291 283 275 261 249 239 229 221 213 206 200 194 189
6,950 4,780 3,840 3,280 2,910 2,640 2,430 2,260 2,120 2,000 1,770 1,610 1,480 1,370 1,220 1,100 1,020 945 886 837 795 759 726 698 672 649 628 609 592 575 546 521 499 480 462 446 432 419 407 395
CapAcity in thousands of BTU per hour 124,000 77,600 40,300 26,900 13,100 85,000 53,300 27,700 18,500 9,000 68,200 42,800 22,200 14,800 7,220 58,400 36,600 19,000 12,700 6,180 51,700 32,500 16,900 11,300 5,480 46,900 29,400 15,300 10,200 4,970 43,100 27,100 14,100 9,380 4,570 40,100 25,200 13,100 8,730 4,250 37,700 23,600 12,300 8,190 3,990 35,600 22,300 11,600 7,730 3,770 31,500 19,800 10,300 6,850 3,340 28,600 17,900 9,300 6,210 3,020 26,300 16,500 8,560 5,710 2,780 24,400 15,300 7,960 5,320 2,590 21,700 13,600 7,060 4,710 2,290 19,600 12,300 6,400 4,270 2,080 18,100 11,300 5,880 3,930 1,190 16,800 10,500 5,470 3,650 1,780 15,800 9,890 5,140 3,430 1,670 14,900 9,340 4,850 3,240 1,580 14,100 8,870 4,610 3,070 1,500 13,500 8,460 4,400 2,930 1,430 12,900 8,110 4,210 2,810 1,370 12,400 7,790 4,040 2,700 1,310 12,000 7,500 3,900 2,600 1,270 11,500 7,240 3,760 2,510 1,220 11,200 7,010 3,640 2,430 1,180 10,800 6,800 3,530 2,360 1,150 10,500 6,600 3,430 2,290 1,110 10,200 6,420 3,330 2,230 1,080 9,720 6,100 3,170 2,110 1,030 9,270 5,820 3,020 2,020 982 8,880 5,570 2,890 1,930 940 8,530 5,350 2,780 1,850 903 8,220 5,160 2,680 1,790 870 1,730 840 7,940 4,980 2,590 1,670 813 7,680 4,820 2,500 789 7,450 4,670 2,430 1,620 766 7,230 4,540 2,360 1,570 745 7,030 4,410 2,290 1,530
219,000 150,000 121,000 103,000 91,500 82,900 76,300 70,900 66,600 62,900 55,700 50,500 46,500 43,200 38,300 34,700 31,900 29,700 27,900 26,300 25,000 23,900 22,800 21,900 21,100 20,400 19,800 19,200 18,600 18,100 17,200 16,400 15,700 15,100 14,500 14,000 13,600 13,200 12,800 12,400
446,000 306,000 246,000 211,000 187,000 169,000 156,000 145,000 136,000 128,000 114,000 103,000 94,700 88,100 78,100 70,800 65,100 60,600 56,800 53,700 51,000 48,600 46,600 44,800 43,100 41,600 40,300 39,100 37,900 36,900 35,000 33,400 32,000 30,800 29,600 28,600 27,700 26,900 26,100 25,400
Note: All table entries are rounded to 3 significant digits.
236
This section is an excerpt from the NFPA 54 National Fuel Gas Code â&#x20AC;&#x201D; 2006 Edition
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Propane 2#
Table 6.3 (c) Schedule 40 Metallic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity
Undiluted Propane 2.0 psi 1.0 psi 1.50
Pipe Size (inches) 1/2
3/4
1
11/4
11/2
2
21/2
3
4
Actual ID
0.622
0.824
1.049
1.380
1.610
2.067
2.469
3.068
4.026
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000
2,680 1,840 1,480 1,260 1,120 1,010 934 869 815 770 682 618 569 529 469 425 391 364 341 322 306 292 280 269 259 250 242 235 228 222 210 201 192 185 178 172 166 161 157 152
5,590 3,850 3,090 2,640 2,340 2,120 1,950 1,820 1,700 1,610 1,430 1,290 1,190 1,110 981 889 817 760 714 674 640 611 585 562 541 523 506 490 476 463 440 420 402 386 372 359 348 337 327 318
CapAcity in thousands of BTU per hour 99,500 62,400 32,400 21,600 10,500 68,400 42,900 22,300 14,900 7,240 54,900 34,500 17,900 11,900 5,820 47,000 29,500 15,300 10,200 4,980 41,700 26,100 13,600 9,060 4,410 37,700 23,700 12,300 8,210 4,000 34,700 21,800 11,300 7,550 3,680 32,300 20,300 10,500 7,020 3,420 30,300 19,000 9,880 6,590 3,210 28,600 18,000 9,330 6,230 3,030 25,400 15,900 8,270 5,520 2,690 23,000 14,400 7,490 5,000 2,440 21,200 13,300 6,890 4,600 2,240 19,700 12,300 6,410 4,280 2,080 17,400 10,900 5,680 3,790 1,850 15,800 9,920 5,150 3,440 1,670 14,500 9,120 4,740 3,160 1,540 13,500 8,490 4,410 2,940 1,430 12,700 7,960 4,130 2,760 1,340 12,000 7,520 3,910 2,610 1,270 11,400 7,140 3,710 2,480 1,210 10,900 6,820 3,540 2,360 1,150 10,400 6,530 3,390 2,260 1,100 9,990 6,270 3,260 2,170 1,060 9,630 6,040 3,140 2,090 1,020 9,300 5,830 3,030 2,020 985 9,000 5,640 2,930 1,960 953 8,720 5,470 2,840 1,900 924 8,470 5,310 2,760 1,840 897 8,240 5,170 2,680 1,790 873 7,830 4,910 2,550 1,700 829 7,470 4,680 2,430 1,620 791 7,150 4,490 2,330 1,550 757 6,870 4,310 2,240 1,490 727 6,620 4,150 2,160 1,440 701 1,390 677 6,390 4,010 2,080 1,340 655 6,180 3,880 2,010 635 6,000 3,760 1,950 1,300 617 5,820 3,650 1,900 1,270 600 5,660 3,550 1,840 1,230
176,000 121,000 97,100 83,100 73,700 66,700 61,400 57,100 53,600 50,600 44,900 40,700 37,400 34,800 30,800 27,900 25,700 23,900 22,400 21,200 20,100 19,200 18,400 17,700 17,000 16,400 15,900 15,400 15,000 14,600 13,800 13,200 12,600 12,100 11,700 11,300 10,900 10,600 10,300 10,000
359,000 247,000 198,000 170,000 150,000 136,000 125,000 116,000 109,000 103,000 91,500 82,900 76,300 71,000 62,000 57,000 52,400 48,800 45,800 43,200 41,100 39,200 37,500 36,000 34,700 33,500 32,400 31,500 30,500 29,700 28,200 26,900 25,800 24,800 23,900 23,000 22,300 21,600 21,000 20,400
Note: All table entries are rounded to 3 significant digits.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
237
appendices
Nominal
12
SECTION
12
Gas Line Sizing Propane 11” W.C.
Table 6.3 (d) Schedule 40 Metallic Pipe SPECIAL USE: Pipe Sizing Between Single or Second Stage (Low Pressure Regulator) and Appliance Gas Inlet Pressure Pressure Drop Specific Gravity
Undiluted Propane 11.0 inches W.C. 0.5 inches W.C. 1.50 Pipe Size (inches)
Nominal Inside
1/2
3/4
1
11/4
11/2
2
21/2
3
4
Actual
0.622
0.824
1.049
1.380
1.610
2.067
2.469
3.068
4.026
Length (feet) 10 20 30 40 50 60 80 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000
291 200 160 137 122 110 101 94 89 84 74 67 62 58 51 46 42 40 37 35 33 32 30 29 28 27 26 25 25 24 23 22 21 20 19 19 18 18
608 418 336 287 255 231 212 197 185 175 155 140 129 120 107 97 89 83 78 73 70 66 64 61 59 57 55 53 52 50 48 46 44 42 40 39 38 37
1,150 787 632 541 480 434 400 372 349 330 292 265 243 227 201 182 167 156 146 138 131 125 120 115 111 107 104 100 97 95 90 86 82 79 76 74 71 69
CapAcity in thousands of BTU per hour 10,800 6,790 3,520 2,350 7,430 4,660 2,420 1,620 5,970 3,750 1,940 1,300 5,110 3,210 1,660 1,110 4,530 2,840 1,480 985 4,100 2,570 1,340 892 3,770 2,370 1,230 821 3,510 2,200 1,140 763 3,290 2,070 1,070 716 3,110 1,950 1,010 677 2,760 1,730 899 600 2,500 1,570 814 543 2,300 1,440 749 500 2,140 1,340 697 465 1,900 1,190 618 412 1,720 1,080 560 373 1,580 991 515 344 1,470 922 479 320 1,380 865 449 300 1,300 817 424 283 1,240 776 403 269 1,180 741 385 257 1,130 709 368 246 1,090 681 354 236 1,050 656 341 227 1,010 634 329 220 978 613 319 213 948 595 309 206 921 578 300 200 895 562 292 195 850 534 277 185 811 509 264 176 777 487 253 169 746 468 243 162 719 451 234 156 694 436 226 151 422 219 146 672 409 212 142 652
19,100 13,100 10,600 9,030 8,000 7,250 6,670 6,210 5,820 5,500 4,880 4,420 4,060 3,780 3,350 3,040 2,790 2,600 2,440 2,300 2,190 2,090 2,000 1,920 1,850 1,790 1,730 1,680 1,630 1,580 1,500 1,430 1,370 1,320 1,270 1,230 1,190 1,150
39,000 26,800 21,500 18,400 16,300 14,800 13,600 12,700 11,900 11,200 9,950 9,010 8,290 7,710 6,840 6,190 5,700 5,300 4,970 4,700 4,460 4,260 4,080 3,920 3,770 3,640 3,530 3,420 3,320 3,230 3,070 2,930 2,800 2,690 2,590 2,500 2,420 2,350
Note: All table entries are rounded to 3 significant digits.
238
This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code — 2008 Edition
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Propane 10#
Table 6.3 (e) Semi-Rigid Copper Tubing SPECIAL USE: Tube Sizing Between First Stage (High Pressure Regulator) and Second Stage (Low Pressure Regulator) Gas Inlet Pressure Pressure Drop Specific Gravity
Undiluted Propane 10.0 psi 1.0 psi 1.50 Tube Size (inches)
K&L Nominal
ACR
1/4
3/8
1/2
5/8
3/4
1
11/4
11/2
2
1/2
5/8
3/4
7/8
11/8
13/8
—
—
0.375
0.500
0.625
0.750
0.875
1.125
1.375
1.625
2.125
Inside*
0.305
0.402
0.527
0.652
0.745
0.995
1.245
1.481
1.959
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000
513 352 283 242 215 194 179 166 156 147 131 118 109 101 90 81 75 70 65 62 59 56 54 51 50 48 46 45 44 42 40 38 37 35 34 33 32 31 30 29
1,060 727 584 500 443 401 369 343 322 304 270 244 225 209 185 168 155 144 135 127 121 115 111 106 102 99 96 93 90 88 83 79 76 73 70 68 66 64 62 60
CapAcity in thousands of BTU per hour 20,500 11,400 5,330 3,760 2,150 14,100 7,830 3,670 2,580 1,480 11,300 6,290 2,940 2,080 1,190 9,690 5,380 2,520 1,780 1,020 8,590 4,770 2,230 1,570 901 7,780 4,320 2,020 1,430 816 7,160 3,980 1,860 1,310 751 6,660 3,700 1,730 1,220 699 6,250 3,470 1,630 1,150 655 5,900 3,280 1,540 1,080 619 5,230 2,910 1,360 959 549 4,740 2,630 1,230 869 497 4,360 2,420 1,130 799 457 4,060 2,250 1,060 744 426 3,600 2,000 935 659 377 3,260 1,810 847 597 342 3,000 1,660 779 549 314 2,790 1,550 725 511 292 2,620 1,450 680 480 274 2,470 1,370 643 453 259 2,350 1,300 610 430 246 2,240 1,240 582 410 235 2,140 1,190 558 393 225 2,060 1,140 536 378 216 1,980 1,100 516 364 208 1,920 1,060 498 351 201 1,850 1,030 482 340 195 1,800 1,000 468 330 189 1,750 970 454 320 183 1,700 944 442 311 178 1,610 896 420 296 169 1,540 855 400 282 161 1,470 819 383 270 155 1,420 787 368 260 148 1,360 758 355 250 143 1,320 732 343 241 138 1,270 708 331 234 134 1,240 687 321 227 130 1,200 667 312 220 126 1,170 648 304 214 122
32,300 22,200 17,900 15,300 13,500 12,300 11,300 10,500 9,850 9,310 8,250 7,470 6,880 6,400 5,670 5,140 4,730 4,400 4,130 3,900 3,700 3,530 3,380 3,250 3,130 3,020 2,920 2,840 2,750 2,680 2,540 2,430 2,320 2,230 2,150 2,080 2,010 1,950 1,890 1,840
67,400 46,300 37,200 31,800 28,200 25,600 23,500 21,900 20,500 19,400 17,200 15,600 14,300 13,300 11,800 10,700 9,840 9,160 8,590 8,120 7,710 7,350 7,040 6,770 6,520 6,290 6,090 5,910 5,730 5,580 5,300 5,050 4,840 4,650 4,480 4,330 4,190 4,060 3,940 3,830
Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
239
appendices
3/8
outside
12
SECTION
12
Gas Line Sizing Propane 2#
Table 6.3 (g) Semi-Rigid Copper Tubing Gas Inlet Pressure Pressure Drop Specific Gravity
Undiluted Propane 2.0 psi 1.0 psi 1.50
Tube Size (inches) K&L Nominal
ACR
1/4
3/8
1/2
5/8
3/4
1
11/4
11/2
2
3/8
1/2
5/8
3/4
7/8
11/8
13/8
—
—
outside
0.375
0.500
0.625
0.750
0.875
1.125
1.375
1.625
2.125
Inside*
0.305
0.402
0.527
0.652
0.745
0.995
1.245
1.481
1.959
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000
413 284 228 195 173 157 144 134 126 119 105 95 88 82 72 66 60 56 53 50 47 45 43 41 40 39 37 36 35 34 32 31 30 28 27 26 26 25 24 23
852 585 470 402 356 323 297 276 259 245 217 197 181 168 149 135 124 116 109 103 97 93 89 86 82 80 77 75 72 71 67 64 61 59 57 55 53 51 50 48
CapAcity in thousands of BTU per hour 16,500 9,170 4,300 3,030 1,730 11,400 6,310 2,950 2,080 1,190 9,120 5,060 2,370 1,670 956 7,800 4,330 2,030 1,430 818 6,920 3,840 1,800 1,270 725 6,270 3,480 1,630 1,150 657 5,760 3,200 1,500 1,060 605 5,360 2,980 1,390 983 562 5,030 2,790 1,310 922 528 4,750 2,640 1,240 871 498 4,210 2,340 1,100 772 442 3,820 2,120 992 700 400 3,510 1,950 913 644 368 3,270 1,810 849 599 343 2,900 1,610 753 531 304 2,620 1,460 682 481 275 2,410 1,340 628 442 253 2,250 1,250 584 411 235 2,110 1,170 548 386 221 1,990 1,110 517 365 209 1,890 1,050 491 346 198 1,800 1,000 469 330 189 1,730 959 449 316 181 1,660 921 431 304 174 1,600 888 415 293 168 1,540 857 401 283 162 1,490 829 388 274 157 1,450 804 376 265 152 1,410 781 366 258 147 1,370 760 356 251 143 1,300 721 338 238 136 1,240 688 322 227 130 1,190 659 309 217 124 1,140 633 296 209 120 1,100 610 286 201 115 1,060 589 276 194 111 1,030 570 267 188 108 1,000 553 259 182 104 966 537 251 177 101 940 522 244 172 99
26,000 17,900 14,400 12,300 10,900 9,880 9,090 8,450 7,930 7,490 6,640 6,020 5,540 5,150 4,560 4,140 3,800 3,540 3,320 3,140 2,980 2,840 2,720 2,620 2,520 2,430 2,350 2,280 2,220 2,160 2,050 1,950 1,870 1,800 1,730 1,670 1,620 1,570 1,520 1,480
54,200 37,300 29,900 25,600 22,700 20,600 18,900 17,600 16,500 15,600 13,800 12,500 11,500 10,700 9,510 8,610 7,920 7,370 6,920 6,530 6,210 5,920 5,670 5,450 5,250 5,070 4,900 4,750 4,620 4,490 4,270 4,070 3,900 3,740 3,610 3,480 3,370 3,270 3,170 3,090
Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
240
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Propane 11” W.C.
Table 6.3 (f) Semi-Rigid Copper Tubing SPECIAL USE: Tube Sizing Between Single or Second Stage (Low Pressure Regulator) and Appliance Gas Inlet Pressure Pressure Drop Specific Gravity
Undiluted Propane 11.0 inches W.C. 0.5 inches W.C. 1.50 Tube Size (inches)
K&L Nominal
ACR
1/4
3/8
1/2
5/8
3/4
1
11/4
11/2
2
1/2
5/8
3/4
7/8
11/8
13/8
—
—
0.375
0.500
0.625
0.750
0.875
1.125
1.375
1.625
2.125
Inside*
0.305
0.402
0.527
0.652
0.745
0.995
1.245
1.481
1.959
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000 1,100 1,200 1,300 1,400 1,500 1,600 1,700 1,800 1,900 2,000
45 31 25 21 19 17 16 15 14 13 11 10 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
93 64 51 44 39 35 32 30 28 27 24 21 20 18 16 15 14 13 12 11 11 10 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
CapAcity in thousands of BTU per hour 1,800 997 467 329 188 1,230 685 321 226 129 991 550 258 182 104 848 471 220 155 89 752 417 195 138 79 681 378 177 125 71 626 348 163 115 66 583 324 152 107 61 547 304 142 100 57 517 287 134 95 54 458 254 119 84 48 415 230 108 76 44 382 212 99 70 40 355 197 92 65 37 315 175 82 58 33 285 158 74 52 30 262 146 68 48 28 244 136 63 45 26 229 127 60 42 24 216 120 56 40 23 205 114 53 38 22 196 109 51 36 21 188 104 49 34 20 180 100 47 33 19 174 96 45 32 18 168 93 44 31 18 162 90 42 30 17 157 87 41 29 17 153 85 40 28 16 149 83 39 27 16 141 78 37 26 15 135 75 35 25 14 129 72 34 24 14 124 69 32 23 13 119 66 31 22 13 115 64 30 21 12 112 62 29 20 12 108 60 28 20 11 105 58 27 19 11 102 57 27 19 11
2,830 1,950 1,560 1,340 1,180 1,070 988 919 862 814 722 654 602 560 496 449 414 385 361 341 324 309 296 284 274 264 256 248 241 234 223 212 203 195 188 182 176 170 166 161
5,890 4,050 3,250 2,780 2,470 2,240 2,060 1,910 1,800 1,700 1,500 1,360 1,250 1,170 1,030 936 861 801 752 710 674 643 616 592 570 551 533 517 502 488 464 442 423 407 392 378 366 355 345 335
NA means a flow of less than 10,000 BTU/hr. Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code — 2008 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
241
appendices
3/8
outside
12
SECTION
12
Gas Line Sizing Propane 10#
Table 15.1 (o) Polyethylene Plastic SPECIAL USE: Pipe Sizing Between First Stage and Second Stage Regulators Gas Inlet Pressure Pressure Drop Specific Gravity
Undiluted Propane 10 psi 1 psi 1.50 Nominal outside diameter (IPS) Pipe Size (inches)
Nominal OD
1/2
3/4
1
11/4
11/2
2
Designation
SDR 9.33
SDR 11.0
SDR 10.00
SDR 11.00
SDR 11.00
SDR 11.0
Actual ID
(0.660)
(0.860)
(1.077)
(1.328)
(1.554)
(1.943)
20,260 17,340 15,368 13,924 12,810 11,918 11,182 10,562 9,361 8,482 7,803 7,259 6,811 6,434 6,111 5,830 5,363 4,989 4,681 4,422 4,007 3,686 3,429 3,217 3,039 2,441 2,089
36,402 31,155 27,612 25,019 23,017 21,413 20,091 18,978 16,820 15,240 14,020 13,043 12,238 11,560 10,979 10,474 9,636 8,965 8,411 7,945 7,199 6,623 6,161 5,781 5,461 4,385 3,753
length (feet) 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400 450 500 600 700 800 900 1000 1500 2000
2,143 1,835 1,626 1,473 1,355 1,261 1,183 1,117 990 897 826 778 721 681 646 617 567 528 495 468 424 390 363 340 322 258 221
4,292 3,673 3,256 2,950 2,714 2,525 2,369 2,238 1,983 1,797 1,653 1,539 1,443 1,363 1,294 1,235 1,136 1,057 992 937 849 781 726 682 644 517 443
CapAcity in thousands of BTU per hour 7,744 13,416 6,628 11,482 5,874 10,176 5,322 9,220 4,896 8,483 4,555 7,891 4,274 7,404 4,037 6,994 3,578 6,199 3,242 5,616 2,983 5,167 2,775 4,807 2,603 4,510 2,459 4,260 2,336 4,046 2,228 3,860 2,050 3,551 1,907 3,304 1,789 3,100 1,690 2,928 1,531 2,653 1,409 2,441 1,311 2,271 1,230 2,131 1,162 2,012 933 1,616 798 1,383
Note: (1) Maximum undiluted propane capacities listed are based on a pressure of 10 psig first-stage setting and 1 psi pressure drop. Capacities in 1000 BTU/hr. (2) Dimensions in parentheses are inside diameter.
This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code â&#x20AC;&#x201D; 2008 Edition
242
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Propane 11” W.C.
Table 6.3 (k) Polyethylene Plastic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity
Undiluted Propane 11.0 inches W.C. 0.5 inches W.C. 1.50
Pipe Size (inches) Nominal oD
1/2
3/4
1
11/4
11/2
2
Designation
SDR 9.33
SDR 11.00
SDR 11.00
SDR 10.00
SDR 11.00
SDR 11.00
actual ID
0.660
0.860
1.077
1.328
1.554
1.943
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500
340 233 187 160 142 129 119 110 103 98 87 78 72 67 60 54 50 46 43 41
680 468 375 321 285 258 237 221 207 196 173 157 145 135 119 108 99 92 87 82
3,210 2,210 1,770 1,520 1,340 1,220 1,120 1,040 978 924 819 742 683 635 563 510 469 436 409 387
5,770 3,970 3,180 2,730 2,420 2,190 2,010 1,870 1,760 1,660 1,470 1,330 1,230 1,140 1,010 916 843 784 736 695
CapAcity in thousands of BTU per hour 2,130 1,230 1,460 844 1,170 677 1,000 580 890 514 807 466 742 428 690 398 648 374 612 353 542 313 491 284 452 261 420 243 373 215 338 195 311 179 289 167 271 157 256 148
Note: All table entries are rounded to 3 significant digits.
appendices
Victor/F.w. Webb is weil mclain’s largest distributor.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
243
12
SECTION
12
Gas Line Sizing Propane 10#
Propane 11â&#x20AC;? W.C.
Table 15.1 (p) Polyethylene Plastic
Table 15.1 (q) Polyethylene Plastic
SPECIAL USE: Tube Sizing Between First Stage and Second Stage Regulators
SPECIAL USE: Tube Sizing Between First Stage and Second Stage Regulators
Gas Inlet Pressure Pressure Drop Specific Gravity
Gas Inlet Pressure Pressure Drop Specific Gravity
Undiluted Propane 10 psi 10 psi 1.50 Nominal outside diameter (CTS)
Undiluted Propane 11.0 inches W.C. 0.5 inches W.C. 1.50 Nominal outside diameter (CTS)
Pipe Size (inches)
Pipe Size (inches)
Nominal OD
1/2
1
Nominal OD
1/2
1
Designation
SDR 7.00
SDR 11.00
Designation
SDR 7.00
SDR 11.00
Actual ID
(0.445)
(0.927)
Actual ID
(0.445)
(0.927)
length (feet) 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400 450 500 600 700 800 900 1000 1500 2000
CapAcity in thousands of BTU per hour 762 5,225 653 4,472 578 3,964 524 3,591 482 3,304 448 3,074 421 2,884 397 2,724 352 2,414 319 2,188 294 2,013 273 1,872 256 1,757 242 1,659 230 1,576 219 1,503 202 1,383 188 1,287 176 1,207 166 1,140 151 1,033 139 951 129 884 121 830 114 784 92 629 79 539
Note: (1) Maximum undiluted propane capacities listed are based on a pressure of 10 psig first-stage setting and 1 psi pressure drop. Capacities in 1000 BTU/hr. (2) Dimensions in parentheses are inside diameter.
length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400
CapAcity in thousands of BTU per hour 121 829 83 569 67 457 57 391 51 347 46 314 42 289 39 269 37 252 35 238 31 211 28 191 26 176 24 164 22 154 21 145 20 138 19 132 18 121 16 113
Note: (1) Maximum undiluted propane capacities listed are based on a pressure of 11 in. W.C. setting and a 0.5 in. W.C. pressure drop. Capacities in 1000 BTU/hr. (2) Dimensions in parentheses are inside diameter.
This section is an excerpt from the NFPA 58 Liquefied Petroleum Gas Code â&#x20AC;&#x201D; 2008 Edition
244
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Natural Gas Low Pressure
Table 6.2(b) Schedule 40 Metallic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity
Natural Less than 2 psi 0.5 inches W.C. 0.60 PIPE Size (inches) 1/2
3/4
1
11/4
11/2
2
21/2
3
4
5
6
8
10
12
0.622
0.824
1.049
1.380
1.610
2.067
2.469
3.068
4.026
5.047
6.065
7.981
10.020
11.938
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000
172 118 95 81 72 65 60 56 52 50 44 40 37 34 30 27 25 23 22 21 20 19 18 17 17 16 16 15 15 14
360 247 199 170 151 137 126 117 110 104 92 83 77 71 63 57 53 49 46 43 41 39 38 36 35 34 33 32 31 30
678 466 374 320 284 257 237 220 207 195 173 157 144 134 119 108 99 92 86 82 78 74 71 68 66 63 61 59 58 56
1,390 957 768 657 583 528 486 452 424 400 355 322 296 275 244 221 203 189 177 168 159 152 145 140 135 130 126 122 118 115
CapAcity in Cubic Feet of Gas per hour 11,300 23,100 41,800 6,400 4,020 2,090 7,780 15,900 28,700 4,400 2,760 1,430 6,250 12,700 23,000 3,530 2,220 1,150 5,350 10,900 19,700 3,020 2,900 985 17,500 9,660 4,740 2,680 1,680 873 15,800 8,760 4,290 2,430 1,520 791 14,600 8,050 3,950 2,230 1,400 728 13,600 7,490 3,670 2,080 1,300 677 12,700 7,030 3,450 1,950 1,220 635 12,000 6,640 3,260 1,840 1,160 600 10,600 5,890 2,890 1,630 1,020 532 9,650 5,330 2,610 1,480 928 482 8,880 4,910 2,410 1,360 854 443 8,260 4,560 2,240 1,270 794 412 7,320 4,050 1,980 1,120 704 366 6,630 3,670 1,800 1,020 638 331 6,100 3,370 1,650 935 587 305 5,680 3,140 1,540 870 546 283 5,330 2,940 1,440 816 512 266 5,030 2,780 1,360 771 484 251 4,780 2,640 1,290 732 459 239 4,560 2,520 1,240 699 438 228 4,360 2,410 1,180 669 420 218 4,190 2,320 1,140 643 403 209 4,040 2,230 1,090 619 389 202 3,900 2,160 1,060 598 375 195 3,780 2,090 1,020 579 363 189 3,660 2,020 992 561 352 183 3,550 1,960 963 545 342 178 3,460 1,910 937 530 333 173
67,600 46,500 37,300 31,900 28,300 25,600 23,600 22,000 20,600 19,500 17,200 15,600 14,400 13,400 11,900 10,700 9,880 9,190 8,620 8,150 7,740 7,380 7,070 6,790 6,540 6,320 6,110 5,930 5,760 5,600
139,000 95,500 76,700 65,600 58,200 52,700 48,500 45,100 42,300 40,000 35,400 32,100 29,500 27,500 24,300 22,100 20,300 18,900 17,700 16,700 15,900 15,200 14,500 14,000 13,400 13,000 12,600 12,200 11,800 11,500
252,000 173,000 139,000 119,000 106,000 95,700 88,100 81,900 76,900 72,600 64,300 58,300 53,600 49,900 44,200 40,100 36,900 34,300 32,200 30,400 28,900 27,500 26,400 25,300 24,400 23,600 22,800 22,100 21,500 20,900
399,000 275,000 220,000 189,000 167,000 152,000 139,000 130,000 122,000 115,000 102,000 92,300 84,900 79,000 70,000 63,400 58,400 54,300 50,900 48,100 45,700 43,600 41,800 40,100 38,600 37,300 36,100 35,000 34,000 33,100
1,100 1,200 1,300 1,400 1,500
14 13 12 12 11
28 27 26 25 24
53 51 49 47 45
109 104 100 96 93
164 156 150 144 139
316 301 289 277 267
503 480 460 442 426
890 849 813 781 752
1,810 1,730 1,660 1,590 1,530
3,280 3,130 3,000 2,880 2,780
5,320 5,070 4,860 4,670 4,500
10,900 10,400 9,980 9,590 9,240
19,800 18,900 18,100 17,400 16,800
31,400 30,000 28,700 27,600 26,600
1,600 1,700 1,800 1,900 2,000
11 11 10 10 NA
23 22 22 21 20
44 42 41 40 39
89 86 84 81 79
134 130 126 122 119
258 250 242 235 229
411 398 386 375 364
727 703 682 662 644
1,480 1,430 1,390 1,350 1,310
2,680 2,590 2,520 2,440 2,380
4,340 4,200 4,070 3,960 3,850
8,920 8,630 8,370 8,130 7,910
16,200 15,700 15,200 14,800 14,400
25,600 24,800 24,100 23,400 22,700
NA means a flow of less than 10,000 BTU/hr. Note: All table entries are rounded to 3 significant digits.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
245
appendices
Nominal Actual ID
12
SECTION
12
Gas Line Sizing Natural Gas 2#
Table 6.2(c) Schedule 40 Metallic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity
Natural 2.0 psi 1.0 psi 0.60 PIPE Size (inches)
Nominal
1/2
3/4
1
11/4
11/2
2
21/2
3
4
Actual ID
0.622
0.824
1.049
1.380
1.610
2.067
2.469
3.068
4.026
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000
1,510 1,070 869 753 673 615 569 532 502 462 414 372 344 318 279 253 232 216 203 192 182 174 166 160 154 149 144 139 135 132
3,040 2,150 1,760 1,520 1,360 1,240 1,150 1,080 1,010 934 836 751 695 642 583 528 486 452 424 401 381 363 348 334 322 311 301 292 283 275
5,560 3,930 3,210 2,780 2,490 2,270 2,100 1,970 1,850 1,710 1,530 1,370 1,270 1,170 1,040 945 869 809 759 717 681 650 622 598 576 556 538 522 507 493
CapAcity in Cubic Feet of Gas per hour 52,500 32,900 17,100 11,400 37,100 23,200 12,100 8,070 30,300 19,000 9,880 6,590 26,400 16,500 8,550 5,710 23,500 14,700 7,650 5,110 21,400 13,500 6,980 4,660 19,900 12,500 6,470 4,320 18,600 11,700 6,050 4,040 17,500 11,000 5,700 3,810 16,100 10,100 5,260 3,510 14,400 9,060 4,700 3,140 13,000 8,130 4,220 2,820 12,000 7,530 3,910 2,601 11,100 6,960 3,610 2,410 9,850 6,180 3,210 2,140 8,920 5,600 2,910 1,940 8,210 5150 2,670 1,790 7,640 4,790 2,490 1,660 7,170 4,500 2,330 1,560 6,770 4,250 2,210 1,470 6,430 4,030 2,090 1,400 6,130 3,850 2,000 1.330 5,870 3,680 1,910 1,280 5,640 3,540 1,840 1,230 5,440 3,410 1,770 1,180 5,250 3,290 1,710 1,140 5,080 3,190 1,650 1,100 4,930 3,090 1,600 1,070 4,780 3,000 1,560 1,040 4,650 2,920 1,520 1,010
92,800 65,600 53,600 46,400 41,500 37,900 35,100 32,800 30,900 28,500 25,500 22,900 21,200 19,600 17,400 15,800 14,500 13,500 12,700 12,000 11,400 10,800 10,400 9,970 9,610 9,280 8,980 8,710 8,460 8,220
189,000 134,000 109,000 94,700 84,700 77,300 71,600 67,000 63,100 58,200 52,100 46,700 43,300 40,000 35,500 32,200 29,600 27,500 25,800 24,400 23,200 22,100 21,200 20,300 19,600 18,900 18,300 17,800 17,200 16,800
1,100 1,200 1,300 1,400 1,500
125 119 114 110 106
262 250 239 230 221
468 446 427 411 396
960 917 878 843 812
1,440 1,370 1,320 1,260 1,220
2,770 2,640 2,530 2,430 2,340
4,420 4,220 4,040 3,880 3,740
7,810 7,450 7,140 6,860 6,600
15,900 15,200 14,600 14,000 13,500
1,600 1,700 1,800 1,900 2,000
102 99 96 93 91
214 207 200 195 189
382 370 358 348 339
784 759 736 715 695
1,180 1,140 1,100 1,070 1,040
2,260 2,190 2,120 2,060 2,010
3,610 3,490 3,390 3,290 3,200
6,380 6,170 5,980 5,810 5,650
13,000 12,600 12,200 11,900 11,500
Note: All table entries are rounded to 3 significant digits.
246
This section is an excerpt from the NFPA 54 National Fuel Gas Code â&#x20AC;&#x201D; 2006 Edition
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Natural Gas 5#
Table 6.2(e) Schedule 40 Metallic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity
Natural 5.0 psi 3.5 psi 0.60 PIPE Size (inches) 1/2
3/4
1
11/4
11/2
2
21/2
3
4
0.622
0.824
1.049
1.380
1.610
2.067
2.469
3.068
4.026
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000
3,190 2,250 1,840 1,590 1,430 1,300 1,200 1,150 1,060 979 876 786 728 673 558 506 465 433 406 384 364 348 333 320 308 298 288 279 271 264
6,430 4,550 3,720 3,220 2,880 2,630 2,430 2,330 2,150 1,980 1,770 1,590 1,470 1,360 1,170 1,060 973 905 849 802 762 727 696 669 644 622 602 584 567 551
11,800 8,320 6,790 5,880 5,260 4,800 4,450 4,260 3,920 3,620 3,240 2,910 2,690 2,490 2,200 1,990 1,830 1,710 1,600 1,510 1,440 1,370 1,310 1,260 1,210 1,170 1,130 1,100 1,070 1,040
CapAcity in Cubic Feet of Gas per hour 111,000 69,700 36,200 24,200 78,600 49,300 25,600 17,100 64,200 40,300 20,900 14,000 55,600 34,900 18,100 12,100 49,700 31,200 16,200 10,800 45,400 28,500 14,800 9,860 42,000 26,400 13,700 9,130 39,300 24,700 12,800 8,540 37,000 23,200 12,100 8,050 34,200 21,400 11,100 7,430 30,600 19,200 9,950 6,640 27,400 17,200 8,940 5,960 25,400 15,900 8,270 5,520 23,500 14,700 7,650 5,100 20,800 13,000 6,760 4,510 18,800 11,800 6,130 4,090 17,300 10,900 5,640 3,760 16,100 10,100 5,250 3,500 15,100 9,480 4,920 3,290 14,300 8,950 4,650 3,100 13,600 8,500 4,420 2,950 12,900 8,110 4,210 2,810 12,400 7,770 4,030 2,690 11,900 7,460 3,880 2,590 11,500 7,190 3,730 2,490 11,100 6,940 3,610 2,410 10,700 6,720 3,490 2,330 10,400 6,520 3,380 2,260 10,100 6,330 3,290 2,190 9,810 6,150 3,200 2,130
196,000 139,000 113,000 98,200 87,900 80,200 74,300 69,500 65,500 60,400 54,000 48,500 44,900 41,500 36,700 33,300 30,600 28,500 26,700 25,200 24,000 22,900 21,900 21,000 20,300 19,600 18,900 18,400 17,800 17,300
401,000 283,000 231,000 200,000 179,000 164,000 151,000 142,000 134,000 123,000 110,000 98,900 91,600 84,700 74,900 67,800 62,400 58,100 54,500 51,500 48,900 46,600 44,600 42,900 41,300 39,900 38,600 37,400 36,400 35,400
1,100 1,200 1,300 1,400 1,500
250 239 229 220 212
524 400 478 460 443
987 941 901 866 834
2,030 1,930 1,850 1,780 1,710
3,030 2,900 2,770 2,660 2,570
5,840 5,580 5,340 5,130 4,940
9,320 8,890 8,510 8,180 7,880
16,500 15,700 15,000 14,500 13,900
33,600 32,000 30,700 29,500 28,400
1,600 1,700 1,800 1,900 2,000
205 198 192 186 181
428 414 401 390 379
806 780 756 734 714
1,650 1,600 1,550 1,510 1,470
2,480 2,400 2,330 2,260 2,200
4,770 4,620 4,480 4,350 4,230
7,610 7,360 7,140 6,930 6,740
13,400 13,000 12,600 12,300 11,900
27,400 26,500 25,700 25,000 24,300
Note: All table entries are rounded to 3 significant digits.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
247
appendices
Nominal Actual ID
12
SECTION
12
Gas Line Sizing Natural Gas Low Pressure
Table 6.2(g) Semi-Rigid Copper Tubing Gas Inlet Pressure Pressure Drop Specific Gravity
Natural Less than 2.0 psi 0.5 inches W.C. 0.60 PIPE Size (inches)
Nominal
k&l
1/4
3/8
1/2
5/8
3/4
1
11/4
11/2
2
Actual ID
acr
3/8
1/2
5/8
3/4
7/8
11/8
13/8
—
—
Outside
0.375
0.500
0.625
0.750
0.875
1.125
1.375
1.625
2.125
Inside*
0.305
0.402
0.527
0.652
0.745
0.995
1.245
1.481
1.959
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000
27 18 15 13 11 10 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
55 38 30 26 23 21 19 18 17 16 14 13 12 11 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA
CapAcity in Cubic Feet of Gas per hour 1,060 590 276 195 111 730 406 190 134 77 586 326 152 107 61 502 279 131 92 53 445 247 116 82 47 403 224 105 74 42 371 206 96 68 39 345 192 90 63 36 324 180 84 59 34 306 170 79 56 32 271 151 70 50 28 245 136 64 45 26 226 125 59 41 24 210 117 55 39 22 186 103 48 34 20 169 94 44 31 18 155 86 40 28 16 144 80 38 26 15 135 75 35 25 14 128 71 33 23 13 122 68 32 22 13 116 64 30 21 12 111 62 29 20 12 107 59 28 20 11 103 57 27 19 11 99 55 26 18 10 96 53 25 18 10 93 52 24 17 NA 90 50 24 17 NA 88 49 23 16 NA
1,680 1,150 925 791 701 635 585 544 510 482 427 387 356 331 294 266 245 228 214 202 192 183 175 168 162 156 151 147 143 139
3,490 2,400 1,930 1,650 1,460 1,320 1,220 1,130 1,060 1,000 890 806 742 690 612 554 510 474 445 420 399 381 365 350 338 326 315 306 297 289
1,100 1,200 1,300 1,400 1,500
NA NA NA NA NA
NA NA NA NA NA
NA NA NA NA NA
15 15 14 13 13
22 21 20 19 18
46 44 42 41 39
84 80 76 73 71
132 126 120 116 111
274 262 251 241 232
1,600 1,700 1,800 1,900 2,000
NA NA NA NA NA
NA NA NA NA NA
NA NA NA NA NA
13 12 12 11 11
18 17 17 16 16
38 37 36 35 34
68 66 64 62 60
108 104 101 98 95
224 217 210 204 199
NA means a flow of less than 10 cfh. Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
248
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Natural Gas 2#
Table 6.2(j) Semi-Rigid Copper Tubing Gas Inlet Pressure Pressure Drop Specific Gravity
Natural 2.0 psi 1.0 psi 0.60 Tube Size (inches)
k&l Nominal
1/4
3/8
1/2
5/8
3/4
1
11/4
11/2
2
3/8
1/2
5/8
3/4
7/8
11/8
13/8
—
—
Outside
0.375
0.500
0.625
0.750
0.875
1.125
1.375
1.625
2.125
0.527
0.652
0.745
0.995
1.245
1.481
1.959
CapAcity in Cubic Feet of Gas per hour 9,820 5,450 2,550 1,800 1,030 6,750 3,750 1,760 1,240 708 5,420 3,010 1,410 993 568 4,640 2,580 1,210 850 486 4,110 2,280 1,070 754 431 3,730 2,070 969 683 391 3,430 1,900 891 628 359 3,190 1,770 829 584 334 2,990 1,660 778 548 314 2,830 1,570 735 518 296 2,500 1,390 651 459 263 2,270 1,260 590 416 238 2,090 1,160 543 383 219 1,940 1,080 505 356 204 1,720 956 448 315 181 1,560 866 406 286 164 1,430 797 373 263 150 1,330 741 347 245 140 1,250 696 326 230 131 1,180 657 308 217 124 1,120 624 292 206 118 1,070 595 279 196 112 1,030 570 267 188 108 986 548 256 181 103 950 528 247 174 100 917 510 239 168 96 888 493 231 163 93 861 478 224 158 90 836 464 217 153 88 813 452 211 149 85
15,500 10,600 8,550 7,310 6,480 5,870 5,400 5,030 4,720 4,450 3,950 3,580 3,290 3,060 2,710 2,460 2,260 2,100 1,970 1,870 1,770 1,690 1,620 1,550 1,500 1,450 1,400 1,360 1,320 1,280
32,200 22,200 17,800 15,200 13,500 12,200 11,300 10,500 9,820 9,280 8,220 7,450 6,850 6,380 5,650 5,120 4,710 4,380 4,110 3,880 3,690 3,520 3,370 3,240 3,120 3,010 2,920 2,830 2,740 2,670
acr
0.305
0.402
245 169 135 116 103 93 86 80 75 71 63 57 52 49 43 39 36 33 31 30 28 27 26 25 24 23 22 22 21 20
506 348 279 239 212 192 177 164 154 146 129 117 108 100 89 80 74 69 65 61 58 55 53 51 49 47 46 44 43 42
1,100 1,200 1,300 1,400 1,500
19 18 18 17 16
40 38 36 35 34
81 77 74 71 68
142 135 129 124 120
201 192 183 176 170
429 409 392 376 363
772 737 705 678 653
1,220 1,160 1,110 1,070 1,030
2,540 2,420 2,320 2,230 2,140
1,600 1,700 1,800 1,900 2,000
16 15 15 14 14
33 31 30 30 29
66 64 62 60 59
116 112 108 105 102
164 159 154 149 145
350 339 329 319 310
630 310 592 575 559
994 962 933 906 881
2,070 2,000 1,940 1,890 1,830
Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
249
appendices
Inside* Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000
12
SECTION
12
Gas Line Sizing Natural Gas 5#
Table 6.2(l) Semi-Rigid Copper Tubing Gas Inlet Pressure Pressure Drop Specific Gravity
Natural 5.0 psi 3.5 psi 0.60 PIPE Size (inches)
k&l Nominal
1/4
3/8
1/2
5/8
3/4
1
11/4
11/2
2
3/8
1/2
5/8
3/4
7/8
11/8
13/8
—
—
Outside
0.375
0.500
0.625
0.750
0.875
1.125
1.375
1.625
2.125
0.652
0.745
0.995
acr
Inside*
0.305
0.402
0.527
1.245
1.481
1.959
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000
511 351 382 241 214 194 178 166 156 147 130 118 109 101 90 81 75 69 65 62 58 56 53 51 49 48 46 45 43 42
1,050 724 582 498 441 400 368 342 321 303 269 243 224 208 185 167 154 143 134 127 121 115 110 106 102 98 95 92 90 87
CapAcity in Cubic Feet of Gas per hour 20,400 11,400 5,320 3,750 2,140 14,000 7,800 3,650 2,580 1,470 11,300 6,270 2,930 2,070 1,180 9,660 5,360 2,510 1,770 1,010 8,560 4,750 2,230 1,570 898 7,750 4,310 2,020 1,420 813 7,130 3,960 1,860 1,310 748 6,640 3,690 1,730 1,220 696 6,230 3,460 1,620 1,140 653 5,880 3,270 1,530 1,080 617 5,210 2,900 1,360 955 547 4,720 2,620 1,230 866 495 4,350 2,410 1,130 796 456 4,040 2,250 1,050 741 424 3,580 1,990 932 657 376 3,250 1,800 844 595 340 2,990 1,660 777 547 313 2,780 1,540 722 509 291 2,610 1,450 678 478 273 2,460 1,370 640 451 258 2,340 1,300 608 429 245 2,230 1,240 580 409 234 2,140 1,190 556 392 224 2,050 1,140 534 376 215 1,980 1,100 514 362 207 1,910 1,060 497 350 200 1,850 1,030 481 339 194 1,790 1,000 466 328 188 1,740 967 452 319 182 1,690 940 440 310 177
32,200 22,200 17,800 15,200 13,500 12,200 11,200 10,500 9,820 9,270 8,220 7,450 6,850 6,370 5,650 5,120 4,170 4,380 4,110 3,880 3,690 3,520 3,370 3,240 3,120 3,010 2,910 2,820 2,740 2,670
67,100 46,100 37,000 31,700 28,100 25,500 23,400 21,800 20,400 19,300 17,100 15,500 14,300 13,300 11,800 10,700 9,810 9,120 8,560 8,090 7,680 7,330 7,020 6,740 6,490 6,270 6,070 5,880 5,710 5,560
1,100 1,200 1,300 1,400 1,500
40 38 37 35 34
83 79 76 73 70
169 161 154 148 143
295 281 269 259 249
418 399 382 367 353
893 852 816 784 755
1,610 1,530 1,470 1,410 1,360
2,530 2,420 2,320 2,220 2,140
5,280 5,040 4,820 4,630 4,460
1,600 1,700 1,800 1,900 2,000
33 32 31 32 29
68 65 63 62 60
138 133 129 125 122
241 233 226 219 213
341 330 320 311 302
729 705 684 664 646
1,310 1,270 1,230 1,200 1,160
2,070 2,000 1,940 1,890 1,830
4,310 4,170 4,040 3,930 3,820
Note: All table entries are rounded to 3 significant digits. * Table capacities are based on Type K copper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
250
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Natural Gas Low Pressure
Table 6.2(s) Polyethylene Plastic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity
Natural Less than 2 psi 0.5 inches in W.C. 0.60 pipe Size (inches)
Nominal OD
1/2
3/4
1
11/4
11/2
2
Designation
SDR 9.33
SDR 11.00
SDR 11.00
SDR 10.00
SDR 11.00
SDR 11.00
Actual ID
0.660
0.860
1.077
1.328
1.554
1.943
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500
201 138 111 95 84 76 70 65 61 58 51 46 43 40 35 32 29 27 26 24
403 277 222 190 169 153 140 131 123 116 103 93 86 80 71 64 59 55 51 48
CapAcity in Cubic Feet of Gas per hour 1,900 1,260 726 1,310 865 499 1,050 695 401 898 594 343 796 527 304 721 477 276 663 439 254 617 409 236 579 383 221 547 362 209 485 321 185 439 291 168 404 268 154 376 249 144 333 221 127 302 200 115 278 184 106 258 171 99 242 160 93 229 152 88
3,410 2,350 1,880 1,610 1,430 1,300 1,190 1,110 1,040 983 871 789 726 675 598 542 499 464 435 411
appendices
12 Note: All table entries are rounded to 3 significant digits.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
251
SECTION
12
Gas Line Sizing Natural Gas 2#
Table 6.2(t) Polyethylene Plastic Pipe Gas Inlet Pressure Pressure Drop Specific Gravity
Natural 2.0 psi 1.0 psi 0.60 pipe Size (inches)
Nominal OD
1/2
3/4
1
11/4
11/2
2
Designation
SDR 9.33
SDR 11.00
SDR 11.00
SDR 10.00
SDR 11.00
SDR 11.00
Actual ID
0.660
0.860
1.077
1.328
1.554
1.943
Length (feet) 10 20 30 40 50 60 70 80 90 100 125 150 175 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1,000
1,860 1,280 1,030 878 778 705 649 603 566 535 474 429 395 368 326 295 272 253 237 224 213 203 194 187 180 174 168 163 158 154
3,720 2,560 2,050 1,760 1,560 1,410 1,300 1,210 1,130 1,070 949 860 791 736 652 591 544 506 475 448 426 406 389 374 360 348 336 326 317 308
17,600 12,100 9,690 8,300 7,350 6,660 6,130 5,700 5,350 5.050 4,480 4,060 3,730 3,470 3,080 2,790 2,570 2,390 2,240 2,120 2,010 1,920 1,840 1,760 1,700 1,640 1,590 1,540 1,500 1,450
31,600 21,700 17,400 14,900 13,200 12,000 11,000 10,200 9,610 9,080 8,050 7,290 6,710 6,240 5,530 5,010 4,610 4,290 4,020 3,800 3,610 3,440 3,300 3,170 3,050 2,950 2,850 2,770 2,690 2,610
1,100 1,200 1,300 1,400 1,500
146 139 134 128 124
293 279 267 257 247
528 504 482 463 446
915 873 836 803 773
1,380 1,320 1,260 1,210 1,170
2,480 2,370 2,270 2,180 2,100
1,600 1,700 1,800 1,900 2,000
119 115 112 109 106
239 231 224 218 212
431 417 404 393 382
747 723 701 680 662
1,130 1,090 1,060 1,030 1,000
2,030 1,960 1,900 1,850 1,800
Note: All table entries are rounded to 3 significant digits.
252
CapAcity in Cubic Feet of Gas per hour 11,600 6,710 7,990 4,610 6,420 3,710 5,490 3,170 4,870 2,810 4,410 2,550 4,060 2,340 3,780 2,180 3,540 2,050 3,350 1,930 2,970 1,710 2,690 1,550 2,470 1,430 2,300 1,330 2,040 1,180 1,850 1,070 1,700 981 1,580 913 1,480 856 1,400 809 1,330 768 1,270 733 1,220 702 1,170 674 1,130 649 1,090 627 1,050 607 1,020 588 990 572 963 556
This section is an excerpt from the NFPA 54 National Fuel Gas Code â&#x20AC;&#x201D; 2006 Edition
Gas Equipment Catalog
victormfg.com
SECTION
12
Gas Line Sizing
Natural Gas Low Pressure
Natural Gas 2#
Table 6.2 (u) Table 6.2 (v) Polyethylene Plastic Tubing Polyethylene Plastic Tubing Gas Inlet Pressure Pressure Drop Specific Gravity
Natural Less than 2.0 psi 0.3 inches W.C. 0.60
Gas Inlet Pressure Pressure Drop Specific Gravity
Natural Less than 2.0 psi 0.5 inches W.C. 0.60
Plastic tubing size (CTS)*
Plastic tubing size (CTS)*
Pipe Size (inches)
Pipe Size (inches)
Nominal OD
1/2
3/4
Nominal OD
1/2
3/4
Designation
SDR 7.00
SDR 11.00
Designation
SDR 7.00
SDR 11.00
Actual ID
0.445
0.927
Actual ID
(0.445)
(0.927)
length (feet) 10 20 30 40 50 60 70 80 90 100
CapAcity in Cubic Feet of GAS per hour 372 54 256 37 205 30 176 26 156 23 141 21 130 19 121 18 113 17 107 16
125 150 175 200
14 13 12 11
95 86 79 74
225 250 275 300
10 NA NA NA
350 400 450 500
NA NA NA NA
length (feet) 10 20 30 40 50 60 70 80 90 100
CapAcity in thousands of BTU per hour 490 72 337 49 271 39 232 34 205 30 186 27 171 25 159 23 149 22 141 21
125 150 175 200
18 17 15 14
125 113 104 97
69 65 62 59
225 250 275 300
13 12 11 11
91 86 82 78
54 51 47 45
350 400 450 500
10 NA NA NA
72 67 63 59
appendices
* CTS = Copper tube size. NA means a flow of less than 10 cfh. Note: All table entries are rounded to 3 significant digits.
This section is an excerpt from the NFPA 54 National Fuel Gas Code — 2006 Edition
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
253
12
GAS INDEX
TO ORDER, CALL: 800.243.9360 • CT: 860.722.2433 • FAX: 800.274.2004
Gas Index A Accessories, Meters & Meter Accessories . . . . . . . . 89 Adapters, Connectors & Fittings, Valves & Accessories . . . . . . . . . . . . . . . . . . . . 64-68 Aluminum Tubing, Gas Heating . . . . . . . . . . . . . . . 166 Anodes, Cylinders, Tanks & Accessories . . . . . . . . . 98 Appendices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 Gas Line Sizing . . . . . . . . . . . . . . . . . . . . . 231-253 Leak Checking Method . . . . . . . . . . . . . . . . 228-230 Liquid Volume Tables & Temperature Correction Factors . . . . . . . . . . . . . . . . . . 225-226 LP Container Requirements . . . . . . . . . . . . 213-222 Orifice Sizing & Propertites of LP Gases . . 223-224 Vaporizer & Electrical Requirements . . . . . . . . . 227 Application Diagrams, Valves & Accessories . . . 75-77 ASME & Dot Cylinders, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . .90-93 ASME Tanks, Cylinders, Tanks & Accessories . . 94-95
B Ball Valves, Valves & Accessories . . . . . . . . . . . 49-52 Barbed Hose Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 139 Black Iron Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . 140-143 Brackets, Regulators & Accessories . . . . . . . . . . . . 10 Bulk Hose, Gas Pipe, Tubing & Fittings . . . . . . . . . 123 Bypass Valves, Pumps & Compressors . . . . . 193-194
C Chemicals, Tools & Chemicals . . . . . . . . . . . . . . . . 211 Coated Copper Tubing, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Compressor Kits, Pumps & Compressors . . . . . . . 179 Compressor Selection Tables, Pumps & Compressors . . . . . . . . . . . . . . . . . . . . 192 Compressors, Pumps & Compressors . . . . . . . . . . 191 Continental Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . 129-133 Copper Tubing, Gas Pipe, Tubing & Fittings . . . . . 122 Counter Strike, Gas Pipe, Tubing & Fittings . . . . . . 119 Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . 90 Anodes, Cylinders . . . . . . . . . . . . . . . . . . . . . . . . 98 ASME & Dot Cylinders . . . . . . . . . . . . . . . . . . 90-93 ASME Replacement Parts, . . . . . . . . . . . . . . . . . 101 ASME Tanks . . . . . . . . . . . . . . . . . . . . . . . . . . 94-95 Cylinder Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . 96 Cylinder Inverters . . . . . . . . . . . . . . . . . . . . . . . . . 96 Cylinder Pads . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . 90
Cylinder Vice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Hand Trucks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Methanol Injector . . . . . . . . . . . . . . . . . . . . . . . . . 97 Motor Fuel Cylinders . . . . . . . . . . . . . . . . . . . . . . 91 OPD Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Pipe Wrap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Scales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Technical Information . . . . . . . . . . . . . . . . . . 98-101 Temperature Monitoring System . . . . . . . . . . . . . . 95 Cylinder & Service Valves, Valves & Accessories . . . . . . . . . . . . . . . . . . . . 30-32 Cylinder Cabinets, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . . 96 Cylinder Gauges, Gauges . . . . . . . . . . . . . . . 107-115 Cylinder Inverters, Cylinders, Tanks & Accessories . . . 96 Cylinder Pads, Cylinders, Tanks & Accessories . . . . 92 Cylinder Vice, Cylinders, Tanks & Accessories . . . . 96
D Decals & Signs, Paint & Supplies . . . . . . . . . . 104-106 Disconnects, Miscellaneous Equipment . . . . . . . . . 209 Dormont Connectors, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . 134-136
E Excess Flow Valves, Valves & Accessories . . . . 53-61
F Filler Valves, Valves & Accessories . . . . . . . . . . . . . 60 Fireplace Products, Miscellaneous Equipment . . . 210 Fittings, Regulators & Accessories . . . . . . . . . . . . . 8-9 Flex Connectors, Pumps & Compressors . . . . . . . 177 Flow Meters, Pumps & Compressors . . . . . . . . . . . 177 Forged Steel Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . 144-148
G Gas Conversion Burners, Miscellaneous Equipment . . . . . . . . . . . . . . . . . . 207 Gas Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Aluminum Tubing . . . . . . . . . . . . . . . . . . . . . . . . 166 Gas Leak System . . . . . . . . . . . . . . . . . . . . . . . . 173 Gas Orifices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 Gas Valve Pressure Regulators . . . . . . . . . . . . . 169 Gas Valves . . . . . . . . . . . . . . 155-158, 160-162, 169 Hot Surface Igniters . . . . . . . . . . . . . . . . . . 170-172 Ignition & Pilot Modules . . . . . . . . . . . . . . . 149-153 Ignitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Pilot Burners . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 Pilot Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
TO ORDER, CALL: 800.243.9360 â&#x20AC;˘ CT: 860.722.2433 â&#x20AC;˘ FAX: 800.274.2004
i
Gas Index G
I
Gas Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Pilots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159, 163 Retrofit Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 Thermocouple & Thermopiles . . . . . . . . . . .163-164 Thermostats . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 Water Feed Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Water Heater Controls . . . . . . . . . . . . . . . . 154-155 Water Safety Valves . . . . . . . . . . . . . . . . . . . . . . 173 Gas Leak System, Gas Heating . . . . . . . . . . . . . . . 173 Gas Lights, Miscellaneous Equipment . . . . . . . . . . 210 Gas Line Sizing, Appendices . . . . . . . . . . . . . 231-253 Gas Orifices, Gas Heating . . . . . . . . . . . . . . . . . . . 166 Gas Outlet Boxes, Miscellaneous Equipment . . . . 209 Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . 118 Barbed Hose Fittings . . . . . . . . . . . . . . . . . . . . . 139 Black Iron Fittings . . . . . . . . . . . . . . . . . . . . 140-143 Bulk Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Coated Copper Tubing . . . . . . . . . . . . . . . . . . . . 122 Continental Fittings . . . . . . . . . . . . . . . . . . . 129-133 Copper Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Counter Strike . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Dormont Connectors . . . . . . . . . . . . . . . . . 134-136 Forged Steel Fittings . . . . . . . . . . . . . . . . . 144-148 Lyall Piping Systems . . . . . . . . . . . . . . . . . . 124-128 LycoFit Mechanical Fittings . . . . . . . . . . . . . . . . 124 LycoFit Tapping Tees . . . . . . . . . . . . . . . . . . . . . 126 LycoFit Installation Tools . . . . . . . . . . . . . . . . . . . 127 LycoRing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 SAE Fittings . . . . . . . . . . . . . . . . . . . . . . . . 137-138 Sediment Traps . . . . . . . . . . . . . . . . . . . . . . . . . 123 TracPipe . . . . . . . . . . . . . . . . . . . . . . . . . . . 118-121 Underground PE Pipe . . . . . . . . . . . . . . . . . . . . . 123 Gas Valve Pressure Regulators, Gas Heating . . . . 169 Gas Valves, Gas Heating . . . . . 155-158, 160-162, 169 Gauges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 Cylinder Gauges . . . . . . . . . . . . . . . . . . . . . 107-115 Pressure Gauges . . . . . . . . . . . . . . . . . . . . . . . . 117 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . 116 Tank Gauges . . . . . . . . . . . . . . . . . . . . . . . 107-115 Gauge Products, Regulators & Accessories . . . . . . . 9 Generators, Miscellaneous Equipment . . . . . 205-206 Globe & Angle Valves, Valves & Accessories . . . 44-48
Ignition & Pilot Modules, Gas Heating . . . . . . 149-153 Ignitors, Gas Heating . . . . . . . . . . . . . . . . . . . . . . . 152 Internal Vales & Accessories, Valves & Accessories . . . . . . . . . . . . . . . . . . . . 62-63
H Hand Trucks, Cylinders, Tanks & Accessories . . . . . 97 Hose Reels, Pumps & Compressors . . . . . . . 175-176 Hot Surface Igniters, Gas Heating . . . . . . . . . 170-172
ii
Gas Equipment Catalog
L Leak Checking Method, Appendices . . . . . . . 228-230 Leak Detectors, Tools & Chemicals . . . . . . . . . . . . 211 Lighters, Tools & Chemicals . . . . . . . . . . . . . . . . . . 211 Liquid Volume Tables & Temperature Correction Factors, Appendices . . . . . . . . . . 225-226 LP Container Requirements, Appendices . . . 213-222 Lyall Piping Systems, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . 124-128 Lyco Fittings, Gas Pipe, Tubing & Fittings . . . 124-128 LycoFit Mechanical Fittings, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 124 LycoFit Tapping Tees, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 126 LycoFit Installation Tools, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 127 LycoRing, Gas Pipe, Tubing & Fittings . . . . . . . . . . 128
M Manifolds, Meters & Meter Accessories . . . . . . . . . . 88 Manifolds, Regulators & Accessories . . . . . . . . . . . . 10 Meters & Meter Accessories . . . . . . . . . . . . . . . . . . . 86 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Meters Bars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86-87 Meters Bars, Meters & Meter Accessories . . . . . . . . 89 Meters, Meters & Meter Accessories . . . . . . . . . 86-87 Methanol Injector, Cylinders, Tanks & Accessories . 97 Miscellaneous Equipment . . . . . . . . . . . . . . . . . . . 207 Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 Fireplace Products . . . . . . . . . . . . . . . . . . . . . . . 210 Gas Conversion Burners . . . . . . . . . . . . . . . . . . 207 Gas Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 Gas Outlet Boxes . . . . . . . . . . . . . . . . . . . . . . . . 209 Generators . . . . . . . . . . . . . . . . . . . . . . . . . 205-206 Vaporizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 Miscellanous Equipment, Valves & Accessories . . . . . . . . . . . . . . . . . . . . 69-74 Motor Fuel Cylinders, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . . . 91 Motors, Pumps & Compressors . . . . . . . . . . . 195-197 Multivalve Assemblies, Valves & Accessories . . 33-36
victormfg.com
Gas Index O OPD Tools, Cylinders, Tanks & Accessories . . . . . . 97 Orifice Sizing & Propertites of LP Gases, Appendices . . . . . . . . . . . . . . . . . . . . . . . . . . 223-224
P Paint & Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Decals & Signs . . . . . . . . . . . . . . . . . . . . . . 104-106 Tank Paint & Supplies . . . . . . . . . . . . . . . . . 102-103 Pigtails, Regulators & Accessories . . . . . . . . . . . . . 7-8 Pilot Burners, Gas Heating . . . . . . . . . . . . . . . . . . . 167 Pilot Kits, Gas Heating . . . . . . . . . . . . . . . . . . . . . . 168 Pilots, Gas Heating . . . . . . . . . . . . . . . . . . . . . 163, 168 Pipe Wrap, Cylinders, Tanks & Accessories . . . . . . . 98 POL Fittings, Regulators & Accessories . . . . . . . . . . 10 Pressure Gauges, Gauges . . . . . . . . . . . . . . . . . . . 117 Pressure Relief Valves & Relief Valve Manifolds, Valves & Accessories . . . . . . . . . . . . . . . . . . . . . 37-43 Propane Flare, Tools & Chemicals . . . . . . . . . . . . . 211 Propane Pumps, Pumps & Compressors . . . . 185-190 Pumps & Compressors . . . . . . . . . . . . . . . . . . . . . 175 Bypass Valves . . . . . . . . . . . . . . . . . . . . . . 193-194 Compressor Kits . . . . . . . . . . . . . . . . . . . . . . . . . 179 Compressor Selection Tables . . . . . . . . . . . . . . . 192 Compressors . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Flex Connectors . . . . . . . . . . . . . . . . . . . . . . . . . 177 Flow Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 Hose Reels . . . . . . . . . . . . . . . . . . . . . . . . . 175-176 Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195-197 Positive Displacement Meters, . . . . . . . . . . . . . 174 Propane Pumps . . . . . . . . . . . . . . . . . . . . . 185-190 Pump Station Kits . . . . . . . . . . . . . . . . . . . . 180-184 Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . 197-204 Strainers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 Swivel Connectors . . . . . . . . . . . . . . . . . . . . . . . 178 Pump Station Kits, Pumps & Compressors . . 180-184
Repair Parts, Pumps & Compressors . . . . . . 197-204 Replacement Parts, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . 101 Replacement Parts, Gauges . . . . . . . . . . . . . . . . . 116 Retrofit Kits, Gas Heating . . . . . . . . . . . . . . . . . . . . 159
S SAE Fittings, Gas Pipe, Tubing & Fittings . . . 137-138 Scales, Cylinders, Tanks & Accessories . . . . . . . . . . 96 Sediment Traps, Gas Pipe, Tubing & Fittings . . . . . 123 Strainers, Pumps & Compressors . . . . . . . . . . . . . 177 Swivel Connectors, Pumps & Compressors . . . . . . 178
T Tank Gauges, Gauges . . . . . . . . . . . . . . . . . . 107-115 Tank Paint & Supplies, Paint & Supplies . . . . 102-103 Technical Information, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . .98-101 Temperature Monitoring System, Cylinders, Tanks & Accessories . . . . . . . . . . . . . . . . . . . . . . . 95 Test Gauge Kit, Tools & Chemicals . . . . . . . . . . . . 211 Test Kits, Tools & Chemicals . . . . . . . . . . . . . . . . . 212 Thermocouple & Thermopiles, Gas Heating . 163-164 Thermostats, Gas Heating . . . . . . . . . . . . . . . . . . . 159 Tools & Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . 211 Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Leak Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Lighters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Propane Flare . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Test Gauge Kit . . . . . . . . . . . . . . . . . . . . . . . . . . 211 Test Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 Tools, Gas Heating . . . . . . . . . . . . . . . . . . . . . . . . . 165 TracPipe, Gas Pipe, Tubing & Fittings . . . . . . 118-121
U Underground PE Pipe, Gas Pipe, Tubing & Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 123
R
V
Regulators & Accessories . . . . . . . . . . . . . . . . . . . . . 1 Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9 Gauge Products . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1 Pigtails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 POL Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Regulator Accessories . . . . . . . . . . . . . . . . . . . . . . 6 Regulators . . . . . . . . . . . . . . . . . . . . . . . . 1-5, 11-29 Regulator Accessories, Regulators & Accessories . . . 6 Regulators, Regulators & Accessories . . . . . 1-5, 11-29 Repair Kits, Valves & Accessories . . . . . . . . . . . 78-85
Valves & Accessories . . . . . . . . . . . . . . . . . . . . . . . . 30 Adapters, Connectors & Fittings . . . . . . . . . . . 64-68 Application Diagrams . . . . . . . . . . . . . . . . . . . 75-77 Ball Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . 49-52 Cylinder & Service Valve . . . . . . . . . . . . . . . . 30-32 Excess Flow Valve . . . . . . . . . . . . . . . . . . . . . 53-61 Filler Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Globe & Angle Valves . . . . . . . . . . . . . . . . . . . 44-48 Internal Vales & Accessories . . . . . . . . . . . . . 62-63 Miscellanous Equipment, . . . . . . . . . . . . . . . . 69-74 Multivalve Assemblies . . . . . . . . . . . . . . . . . . 33-36 Pressure Relief Valves & Relief Valve Manifolds 37-43
TO ORDER, CALL: 800.243.9360 â&#x20AC;˘ CT: 860.722.2433 â&#x20AC;˘ FAX: 800.274.2004
iii
Gas Index V Valves & Accessories . . . . . . . . . . . . . . . . . . . . . . . . 30 Repair Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . 78-85 Vapor Equalizing Valves . . . . . . . . . . . . . . . . . . . . 60 Vapor Equalizing Valves, Valves & Accessories . . . . 60 Vaporizer & Electrical Requirements, Appendices . 227 Vaporizers, Miscellaneous Equipment . . . . . . . . . . 208
W Water Feed Kit, Gas Heating . . . . . . . . . . . . . . . . . 173 Water Heater Controls, Gas Heating . . . . . . . 154-155 Water Safety Valves, Gas Heating . . . . . . . . . . . . . 173
iv
Gas Equipment Catalog
victormfg.com