®
Blood sampling method Less expensive and no painful procedures Patent pending with 3 biomarkers and an algorithm to generate results in 4 different stages Validated with 500+ samples
Hepatitis B Hepatitis C Alcoholic Liver Disease Metabolic / Non-Alcoholic Fatty Liver Disease
BioFibroScore ® platform shows an excellent accuracy (>0.95) in all stages, especially in early stages. The technology has been offered as a service bundling as Liver20 TM.
AUROC BioFibroScore ®
FIBROSIS STAGES F≥1
F≥2
F≥3
F≥4
>0.95
>0.95
>0.95
>0.95
ELISA Kits & Instruments, RT-PCR & instruments, Raw Materials, Labware, & CLIA (new) A No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C. E sales.group@gbc.com.tw
T +886 3 577 9221
F +886 3 577 9227
www.gbc.com.tw
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB WatoTM
An Automatic ELISA Plate Washer
FOCUSING ON YOUR NEEDS Various types of plate can be supported and are easily inter-changeable in the plate carrier to maximize the washing performance. GB WatoTM is an automatic ELISA Strip / Plate Washer with built-in incubator & programmable timer.
PRODUCT HIGHLIGHTS Specifically designed Manifold assembly to prevent any scratching on bottom of well Programmable soak time, wash cycles and dispensing volume Onboard two-plate incubator at 37 with programmable timer Waste bottle full warning with audible alarm Built-in stabilizer Continuous aspiration to prevent overflow Removable manifold Ability to wash single strip of 8 wells
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care. GB WATO TM TECHNICAL SPECIFICATION Manifold
8 Way Manifold Dispensing
Dispensing
Method : Specially designed Peristaltic Pump Volume : 300 to 400 µL in steps of 50 µL
Aspirating
Method : Continuous through diaphragm pump while Dispensing hence preventing overflow Residual Volume : < 5 µL
Waste Bottle
One (Capacity 2 liters) with audible alarm when bottle is completely filled in with waste solution
Wash Bottle
One (Capacity 2 liters)
Rinse Bottle
One (Capacity 2 liters)
Display
Single line Backlit LCD with 16 characters
Liquid contact materials
Silicon, Stainless steel, derline
Memory
8 KB Non volatile RAM battery back up suppor ting 35 open channels
Washing Method
Longwash, Shortwash Rinsing, Priming
Incubator
For Two ELISA Plates, 37º C
Timer
Individually Programmable
Power
Wattage : 50 Watts Voltage : 115 - 230 Volts ± 10%, 50 /60 Hz.
Operating Position
On horizontal, rigid, flat and vibration free surface
Operating Conditions
Temperature : + 18º C to 35º C Humidity : up to 85 %
Storage Conditions
Temperature : - 10º C to 60º C Humidity : up to 85 %
Enclosure
ABS Fire retardant
Size (cm)
35 X 35 X 13 (lxwxh)
Weight
6 Kgs
ORDERING INFORMATION Catalog No. S00346
Description GB WatoTM
Package 1 unit 2013.Mar.
A No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C. E sales.group@gbc.com.tw T +886 3 577 9221
www.gbc.com.tw
F +886 3 577 9227
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB TempCardTM
Temperature Recorder
MADE SPECIALLY FOR YOU GB TempCardTM Temperature Recorder incorporates an innovative temperature sensor built inside this portable device. GB TempCardTM has been designed to endure hard damages yet still provide a fast reaction time.
PRODUCT HIGHLIGHTS Alert indicator – indicates if readings are outside of preset limits OK indicator indicates if still recording and if readings within configured limits Credit card sized case – thin enough to be easily mailed “letter rate”. Real time clock records time & temperature simultaneously Highly reliable and accurate Pre-Start Logging - Configurable to record even when "start" button has not been pressed High performance at lower cost Credit Card sized design - easy to carry and transport Re-calibration function available
USER-FRIENDLY INTERFACE GB TempCardTM comes with a great user-friendly interface software, TempCardTM Analyzer, for reading and analyzing collected data. GB TempCardTM Analyzer provides functions including delayed start, sampling interval, number of readings, continuous or fixed number of readings and ALERT function setup. Data recorded can be downloaded or exported in excel.
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB TEMPCARD TM TECHNICAL SPECIFICATION Capacity
8000 temperature readings (16Kbytes memory)
Frequency
Adjustable, 30 seconds to several hours
Download Time
Typically with full memory in less than 5 seconds depending on computer or readout device used
Environmental
IP65
Battery
3V Lithium
Life
2~3 years on regular uses
Real Time Clock
Installed with Real Time Clock. Rated accuracy ±25ppm @ 25°C (equiv to 2.5 seconds/day) Rated temperature coefficient is -0.034±0.006ppm/°C (i.e typically +/- 0.00294seconds/day/°C)
Dimension
86mm (L) x 55mm (W) x 8.6mm (H)
Weight
35g
Case Material
Polycarbonate
EMC Compliance
Tested and complies with EC EMC directives (EN 50081-1:1992 & EN 61000-6-1:2001)
EN12380 Compliance
Tested and complies to EN12830:1999 for transport, storage and distribution of chilled, frozen, deep frozen, quick-frozen food and others
ORDERING INFORMATION Catalog No. S00351
Description GB TempCardTM
Package 1 unit 2013/Mar.
A No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C. E sales.group@gbc.com.tw T +886 3 577 9221
www.gbc.com.tw
F +886 3 577 9227
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB RitoTM
An Automatic ELISA Plate Reader
FOCUSING ON YOUR NEEDS GB RitoTM is an automatic ELISA Plate Reader with user-friendly touch interface and software. GB RitoTM can be used for all routine immunoassays, biochemicals, hormones, and drug levels. It is an economical reliable and high precision instrument.
PRODUCT HIGHLIGHTS Robust system with built-in stabilizer Built-in shaker with variable speed & duration Results printing in matrix mode format Option to run multiple blank in cut-off mode Bichromatic readings Ability to read from any strip in a single plate Extensive curve plotting
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care. GB RITO TM TECHNICAL SPECIFICATION Interface
TOUCH PANEL / KEYPAD
Linear measurement range
0.000 to 3.000 Absorbance Units(A)
Photometirc Accuracy
± 2% or 0.005 whichever is higher, from 0 to 1.5 A ± 3% from 1.5 A to 3.0 A
Drift
<0.005 A/hr
Photometric Linearity
2.5 A
Optical measurement
8 Channel
Filters
Type of Filter Wave Length Half Bandwidth Selection
Light Source
Tungsten halogen lamp
Warm up time
90 seconds (built - in)
Display
6” Graphics LCD, Negative Blue, STN
Curve Plotting
Graphical Representation on Printer
Plate Carrier Movement
Precisely through the stepper motor
Printer
Built in Thermal Printer 52 columns
Memory
64 KB Non Volatile RAM Battery backup suppor ting125 open channels
Analysis Mode
Absorbance Cut - off Multi - Standard % Absorbance
RS232 Serial Port
2400 baud, 8 data, 1 stop, no parity bits / USB
Power
Wattage : 50 Watts Voltage : 115 - 230 Volts ± 10%, 50 / 60 Hz.
Operating Position
On horizontal flat, rigid and vibration free surface
Operating Conditions
Temperature : From + 18º C to 35º C Relative Humidity : up to 80 %
Storage Conditions
Temperature : From - 10º C to 35º C Relative Humidity : up to 80 %
Enclosure
ABS Fire Retardant
Size (cm)
36 X 36 X 22 (lxwxh)
Weight
10 Kgs
: Narrow band Interference : 405nm, 450nm, 492nm, 560nm, 630nm : 10 nm ± 2nm : Automatic by Stepper Motor
ORDERING INFORMATION Catalog No. S00345
Description GB RitoTM
Package 1 unit 2013.Mar.
A No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C. E sales.group@gbc.com.tw T +886 3 577 9221
www.gbc.com.tw
F +886 3 577 9227
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB HBV RealQuant™ PCR Kit
In-Vitro Quantification of Hepatitis B Virus DNA
FEATURES GB HBV RealQuant™ PCR is an in vitro real time polymerase chain reaction (PCR) kit for the quantitation of Hepatitis B Virus (HBV) DNA in human plasma or serum from HBV-infected individuals.
PERFORMANCE COMPARISON Correlation
Accuracy
GB HBV RealQuant™ PCR kit shows
Base on Clinical and Laboratory Standards
great result comparing with its compara-
Institute (CLSI) documents, the CV should
tor. Both GB HBV RealQuant™ PCR Kit
be less than 35%, and both Comparator
and its comparator show equivalency
HBV Test and GB HBV RealQuant™ PCR
(between
37~107
were passed. Both Comparator HBV Test
IU/mL).
and GB HBV RealQuant™ PCR were shown to be linear in serum across the range of WHO HBV DNA concentrations.
6 GBC
Correlation
log IU/mL
6
Target WHO Conc.
8
R2=0.966
4
2
Accuracy
log IU/mL
5
R2=0.955
4 3
R2=0.955
2 1 0
0 0
2
4
6
8
Comparator
10 log IU/mL
0
1
2
3
4
5
Target HBV Conc.
6 log IU/mL Comparator GB
Comparator
GB HBV RealQuant™ PCR
CT value & Conc.
CT value & Conc.
L1
N/A (>1.1x108 IU/mL)
9.52/3.31x109 IU/mL
L2
N/A (>1.1x108 IU/mL)
8.54/3.47x108 IU/mL
L3
7.58/3.80x107 IU/mL
7.63/4.27x107 IU/mL
Sample ID
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB HBV REALQUANT™ PCR SPECIFICATION Certificates
TFDA / CE
Linear Range
10 IU~2.0E+09 IU/mL for 0.5mL input
LOD
9.8 IU/mL for 0.5mL input, 53 IU/mL for 0.2 mL input
Precision (CV%)
2.00 (log10IU/mL)=13.87%: 4.30 (log10IU/mL)=3.12%; 6.30 (log10IU/mL)=1.41%
Genotype Detection
A, B, C, D, E, F, G, wild types and mutants
Specimen Type
Serum and plasma
Time to Result
All processes including extraction within 3~4 hours (Manual or Automation)
Configuration
Master Mix, Primer, Probe, Internal Control, 5 Quantification Standard
Standardization
WHO International Standard for HBV DNA(97/746)
GB ANALYZER ECOSYSTEM GB GenesisTM e1000 DNA/RNA Extraction System GB GenesisTM s1000 DNA/RNA Extraction System GB GenesisTM s2000 DNA/RNA Extraction System QIAGEN Rotor-Gene Q - 2 channels RealTime PCR Cycler QIAGEN Rotor-Gene Q - 5 channels RealTime PCR Cycler
ORDERING INFORMATION Catalog No. 4HBPA2 S00340 S00341 S00352 S00343 S00353
Description GB HBV RealQuant™ PCR Kit GB Genesis™ e1000 GB Genesis™ s1000 GB Genesis™ s2000 QIAGEN Rotor-Gene Q - 2 channels QIAGEN Rotor-Gene Q - 5 channels
Package 48 tests/kit 1 unit 1 unit 1 unit 1 unit 1 unit 2013.Mar.
A No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C. E sales.group@gbc.com.tw T +886 3 577 9221
www.gbc.com.tw
F +886 3 577 9227
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB HBsAg ELISA Kit (SURASE B-96) Detecting Hepatitis B Surface Antigen FEATURES Certificates: CE marked and TFDA Fulfilled new CTS of the European IVD Directive (2009 / 108 / EC) Detecting all Pre Core Mutant Panel A Hepatitis B Pre Core Mutant Panel from Teragenix, USA was used to test and validate. Studies showed GB HBsAg (SURASE96) can detect the results while panel's dilution ratio is 1:2 or 1:5.
39Y
/C
14
8T
G14
5K
Higher Sensitivity in Mutant Sample Detection
7T
4D
6 E1
C1 4
C1
5R 14
E
L
P142
41
L/G
42
P1
K1
D144G
Higher Sensitivity in Mutant Sample Detection
4N
S17
C137W
113A114
Y134S
P12
0L
31P
22
R 24 C1
T
2I
T123N
E12
22
R1
13
T
R1
1I
122R A123
T1
I
GB HBsAg ELISA Kit (SURASE B-96) SURASE B-96 17 / 21 Reference kit
14 / 21
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB HBsAg SURASE B-96 SPECIFICATION Diagnostic Sensitivity
100% (European Performance Evaluation)
Diagnostic Specificity
99.58% (European Performance Evaluation)
Intra-assay reproducibilty
The calculated CV's range between 3.7% and 11.36%
Time Saving
Without sample dilution & short substrate incubation time
Substrate
TMB
Certification
TFDA/CE
Method
direct sandwich method
Sample Type
serum / plasma
Sample Volume
100 ÂľL
Shelf Life
18 months
GB ANALYZER ECOSYSTEM GB KiwiTM e2000 ELISA Automatic System GB KiwiTM e4000 ELISA Automatic System GB KiwiTM eGility ELISA Automatic System
ORDERING INFORMATION Catalog No. 4SGE3 4SGE11 S00337 S00338 S00339
Description GB HBsAg (SURASE B-96) GB HBsAg (SURASE B-480) GB KiwiTM e2000 ELISA Automatic System GB KiwiTM e4000 ELISA Automatic System GB KiwiTM eGility ELISA Automatic System
Package 96 tests/kit 480 tests/kit 1 unit 1 unit 1 unit 2013.Mar.
A No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C. E sales.group@gbc.com.tw T +886 3 577 9221
www.gbc.com.tw
F +886 3 577 9227
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GBTronic
Automatic Electronic Pipette
FOCUSING ON YOUR NEEDS The GBTronic is one of the easiest electronic pipettes to set and use. You can choose between the most widely used pipetting modes including reverse pipetting, multi dispensing, mixing and squential dispensing, or store up to 9 of your own protocols.
PRODUCT HIGHLIGHTS Consistent accuracy and precision can be easily achieved Userâ&#x20AC;&#x2122;s operation interface is as easy and graphical as your cellular phone Light-weight and ergonomic design prevent Repetitive Stress Injury (RSI) Multiple protocols make your tedious lab job a breeze 9 memory settings for storing your protocols Lithium battery guarantees no leakage and more hours of operation 5 speed settings for different viscous samples Affordable prices Complies with ISO-8655, CE and GLP
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
ORDERING INFORMATION Single Catalog No. S00382 S00383 S00384 S00385
Description 1-channel A-pette electronic pipette, 0.5-10 ul 1-channel A-pette electronic pipette, 2-20 ul 1-channel A-pette electronic pipette, 10-200 ul 1-channel A-pette electronic pipette, 100-1,000 ul
Inaccuracy % / Imprecision % / Color 4-1 2.5-0.4 4-1 2.5-0.4 2.5-0.6 1-0.15 2.5-0.6 0.6-0.15
Description 8-channel A-pette electronic pipette, 0.5-10 ul 8-channel A-pette electronic pipette, 2-20 ul 8-channel A-pette electronic pipette, 10-200 ul 8-channel A-pette electronic pipette, 100-1,200 ul
Inaccuracy % / Imprecision % / Color 4-1.5 2.5-0.5 4-1 2.5-0.5 3-0.6 1-0.15 3-0.5 0.8-0.2
Multi Catalog No. S00386 S00387 S00388 S00389
2013.Mar.
A No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C. E sales.group@gbc.com.tw T +886 3 577 9221
www.gbc.com.tw
F +886 3 577 9227
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB Fit X1TM
Automatic Pipetting System
FOCUSING ON YOUR NEEDS GB Fit X1TM is an automated, high-precision pipetting system specifically designed for low-volume PCR/qPCR sample preparation. Fit X1TM is designed to replace the manual process of PCR/qPCR sample preparation. Precision and consistency are the key feature to make sure reagents are dispensed accurately. Fit X1TM offers simplicity and functionality for you to produce the best results!
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care. GB FIT X1 TM TECHNICAL SPECIFICATION
Worktable Capacity
2 or 3 x 96 / 384 SBS PCR plates 2 or 1 x 96 tip rack (50/200 ul) Reagent Area 1: 8 x 1.5/2 ml microcentrifuge tube Reagent Area 2: 6 x 2 ml storage tube (free standing) and 1 x 5 ml bottle
Function
Liquid (Sample/Reagent) Transfer (LT) Multiple Dispense (MD) Serial Dilution (SD) Hold (Pause) Mixing (MIX) Loop
Automated Pipetting Module
Interchageable 1/8-channel, Maximum volume 50 ul/200 ul
Connection
RS-232, USB 1.0
Power Supply
100~240V, 50/60 Hz, 100W
Size (W x D x H)
590 x 440 x 460 mm
Weight
25 Kg
ORDERING INFORMATION Catalog No.
Description
X1TM
Fit S00390
4-plate Automated Pipetting System with 1 x APM, 1 x PC and SoFitTM software.
Interchangeable Automated Pipetting Module S00391 1-channel, 50 ul Pipetting Module S00392 8-channel, 50 ul Pipetting Module S00393 1-channel, 200 ul Pipetting Module S00394 8-channel, 200 ul Pipetting Module Robotic Tips S00395 S00396 S00397 S00398
FitTipTM 50 ul, non-sterile, 96 tips/rack; 10 racks/pack FitTipTM 200 ul, non-sterile, 96 tips/rack; 10 racks/pack FitTipTM 50 ul, sterile, 96 tips/rack; 10 racks/pack FitTipTM 200 ul, sterile, 96 tips/rack; 10 racks/pack
Accessories S00399 S00400 S00401 S00402 S00403 S00404 S00405 S00406 S00407
96 tips rack adapter Leviated 96-well PCR plate adapter Leviated 384-well PCR plate adapter 4 x 2 1.5ml tubes adapter 3 x 2 2ml storage tubes & 1 x 5 bottle adapter FitTipTM 96 adapter for 96-well PCR plates FitTipTM 384 adapter for 384-well PCR plates FitTipTM R10 adapter for 4 x 2 1.5ml tubes FitTipTM R20 adapter for 3 x 2 2ml storage tubes and 1 x 5ml bottle 2013.Mar.
A No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C. E sales.group@gbc.com.tw T +886 3 577 9221
www.gbc.com.tw
F +886 3 577 9227
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB anti-HCV V4.0 ELISA Kit (NANBASE C-96 V4.0)
EIA Kit for Direct Detection of HCV Antibody FEATURES Certificates: CE marked and TFDA
New Method: double antigen direct sandwich principle Time Saving: without sample dilution and short substrate incubation time
4~7 Days Earlier Detection
HCV Reagent Kit - Brand A
21.6 days
HCV Reagent Kit - Brand B
22.8 days
HCV Reagent Kit - Brand C GB anti-HCV V4.0 (NANBASE C-96 V4.0)
HCV Reagent Kit - Brand D
17.7 days
0
22.9 days
24.9 days
4
8
12
16
20
days
24
HCV Reagent Kit - Brand E HCV Reagent Kit - Brand F
23.5 days 23.0 days
10X More Sensitive
Anti-HCVlgG(S/Co)
30
GB anti-HCV V4.0 (NANBASE C-96 V4.0)
25 20 15 10
CE Marked Reference Kit
5
Cut off
0 0
5
10 15 Serial Dilution Steps
20
PEI Reference Material High Positive Sample 1 High Positive Sample 2 Cut off
Industry-Leading In-Vitro Diagnostic Device Manufactuer
Your Liver. We Care.
GB anti-HCV V4.0 (NANBASE C-96 V4.0) SPECIFICATION Diagnostic Sensitivity
100.00%
Diagnostic Specificity
99.80%
Intra-assay reproducibilty
The calculated CV's range between 4.7% and 8.51%
Time Saving
Without sample dilution & short substrate incubation time
Substrate
TMB
Certification
TFDA/CE
New Method
double antigen direct sandwich principle
Sample Type
serum / plasma
Sample Volume
100 ÂľL
Shelf Life
18 months
GB ANALYZER ECOSYSTEM GB KiwiTM e2000 ELISA Automatic System GB KiwiTM e4000 ELISA Automatic System GB KiwiTM eGility ELISA Automatic System
ORDERING INFORMATION Catalog No. 4NAE3 4NAE12 S00337 S00338 S00339
Description GB anti-HCV V4.0 (NANBASE C-96 V4.0) GB anti-HCV V4.0 (NANBASE C-480 V4.0) GB KiwiTM e2000 ELISA Automatic System GB KiwiTM e4000 ELISA Automatic System GB KiwiTM eGility ELISA Automatic System
Package 96 tests/kit 480 tests/kit 1 unit 1 unit 1 unit
2013.Mar.
A No.6, Innovation First Road, Hsinchu Science Park, Taiwan, R.O.C. E sales.group@gbc.com.tw T +886 3 577 9221
www.gbc.com.tw
F +886 3 577 9227