An innovative keyless cabinet lock operated by radio frequency technology. STEALTHLOCK® CABINET ELECTRONIC LOCKING SYSTEM richelieu.com
STealThlocK® cabineT elecTronic locKing SySTeM
An innovative keyless cabinet lock operated by radio frequency technology.
• Transmitter pad operates within a 15 ft. range
• One transmitter pad can activate an unlimited number of receiver latches
• Separate user and supervisor codes (four to eight digits) to operate the lock(s)
• Receiver latch is easily programmed by user through the transmitter pad
• Receiver latch mounts within ½" drawer suspension clearance
• Uses readily available batteries: 4-AAA (not included) for the receiver latch and a CR2032 coin battery (included) for the transmitter pad
• Low battery indicator on transmitter pad
• For interior use only – recommended temperature range of 50°F to 120°F
important information:
• Batteries should be replaced on an annual basis to insure continued reliability
ref.product description
finishQtY/BoX
- locsl100 Stealthlock system kit Black1
a locrl110 Stealthlock receiver latch kitBlack1
B loctp100 Stealthlock transmitter padBlack1
c locMp300 Stealthlock mounting plate Black1 locMo700 Satin Nickel1
d locsp600 Stealthlock replacement strikeBlack1
e locrlapc9vj10 Stealthlock emergency power cordBlack1
f locrlap1 Stealthlock power supplyBlack1
STealThlocK® cabineT elecTronic locKing
Contains all parts necessary to lock one door or drawer.
applications: Lockers, closet cabinets and storage, kitchen cabinets, liquor cabinets, entertainment units, audio visual cabinets, office furniture, reception and conference furniture, healthcare cabinetry, retail display cabinets
included:
• 1 receiver latch kit
• 1 transmitter pad
• 1 cabinet strike
• 1 installation tool
1
STealThlocK® receiver laTch KiT
Replaces existing cabinet locks. Receiver latch kit needed to lock each additional door or drawer operated by existing transmitter pad.
Receiver kit needed to lock each additional door or drawer operated by existing transmitter pad.**
** For example: To lock a two-door system using one transmitter pad, one LOCSL100 and one LOCRL100 are needed
included:
• 1 receiver latch
• 1 cabinet strike
• 1 installation tool productwidthheightdepthQtY/BoX
Tel.: 1 800 619.5446 • Fax: 1 800 876.7454 richelieu.com
locrl110 6 13/16" (173 mm)
11/16" (68 mm) 7/16" (11 mm) 1
2
locsl100
productQtY/BoX
SySTeM KiT 2.500 63.5 6.785 OVERALL LENGTH OF RECEIVER LATCH 172.3 2.125 54 .210 DISTANCE FROM FRONT EDGE OF CABINET SIDE TO FACE OF RECEIVER LATCH 5.3 .030 GAP BETWEEN CABINET EDGE AND DOOR OR DRAWER FRONT 0.8 2.829 71.9 1.535 39 1.085 27.6 DOOR OR DRAWER FACE BACK OF DOOR OR DRAWER FACE FRONT EDGE OF CABINET SIDE StealthLock Installation Template for Overlay Door/Drawer Applications POSITION MOUNTING SCREWS AT FRONT SIDE OF OVAL HOLES TO ALLOW FORWARD ADJUSTABILITY
a Receiver latch c Stealthlock mounting plate e Stealthlock emergency power cord f StealthLock power supply B Transmitter pad d Replacement strike Installation tool
STealThlocK® TranSMiTTer Pad
Radio frequency technology permits the transmitter pad to be stored anywhere, leaving no trace of visible hardware or signs of being secured.
One transmitter pad can operate a single or multiple receiver latches.
• Transmitter pad operates within a 15 ft range
• Operates with separate and programmable user and supervisor codes
• User programmable with optional modes of operation for single use or self lock
productMaterial widthheightQtY/BoX
loctp100 Plastic3 3/8" (86 mm)1 1/2" (38 mm)1
Suggested product(s):
productdescription
locrl110 Stealthlock® receiver latch kit
locMp300 Stealthlock® mounting plate – black
locMo700 Stealthlock® mounting plate – satin nickel
STealThlocK® MoUnTing PlaTe
Optimal mounting plate for transmitter pad. 5/8" to 7/8" material thickness. Mounting screws and template included. product
Suggested product(s):
productdescription locsl100 Stealthlock® system kit
STealThlocK® eMergency Power cord
Provides emergency power to receiver latch using a 9 volt battery. Can power up to 10 receiver latches using the extension cords.
product lengthQtY/BoX locrlapc9vj10 10' (3.05 m)1
Suggested product(s):
productdescription
locsl100 Stealthlock® system kit
STealThlocK® Power SUPPly
Connects receiver latch to 120 VAC power.
• One power supply can support/power 10 locks
• Includes 5-1/2 foot cord
productMaterial voltage QtY/BoX
locrlap1 Plastic7.5 V1
Suggested product(s): productdescription
locsl100 Stealthlock® system kit
Tel.: 1 800 619.5446 • Fax: 1 800 876.7454 richelieu.com
widthheightdepthQtY/BoX locMp300 Black 4 5/16" (109 mm) 1 13/16" (45 mm) 3/8" (10 mm) 1 locMo700
finish
Satin Nickel
4.29 (109) 0.395 (10) 0.340 (8.6) Holes Tapped 8-32 3.75 (95.3) 1.785 (45.3) Ø0.25 (6.4) Holes Required Ø0.225 (5.7) 3.375 .325 1.500 1.5" 0.325" 3.375"
STealThlocK® rePlaceMenT STriKe PlaTe
Replacement cabinet strike plate for the StealthLock System.
Suggested product(s):
reinForcing TriM ring
1/4" (6 mm) thick exterior through-bolt plate.
• Attractive mounting: External metal throughbolt plate allows for flush mounting of the cabinet lock face with face of cabinet
• Increases security: Reinforces the cabinet face by direct connection of lock mounting screws to through-bolt plate's binder posts
• For large pin series locks 1/4" thick through-bolt plate
olets25026d 1
adjUSTable leveler SeT
For small toe kicks.
The kit is composed of 4 legs:
• 2 front legs (black)
• 2 back legs (red)
The front legs regulation is made at the base of the leg with a standard screwdriver.
Due to the lack of height, the regulation of the back legs is made with specific screwdriver #4370180. The adjustment is made by inserting the screwdriver from the front head. Slide it up to the back head then regulate the leg. Use dedicated head #4370090 for the 4 legs.
allen Key Screwdriver 4 MM red
Long reach and greater torque.
Easier to use than standard Allen wrenches and make tightening hard to reach screws simple. Sold by unit
50
Tel.: 1 800 619.5446 • Fax: 1 800 876.7454 richelieu.com
productMaterial widthheightdepthQtY/BoX locsp600 Plastic 3/8" (10 mm) 1 1/4" (32 mm) 1-3/16" (30 mm) 1
productdescription locsl100 Stealthlock® system kit
productQtY/BoX
1 11/16" 1 9/32" 1/4" 1/4" 8-32 THD 1/2"
productQtY/BoX 4370180
productfinish adjustMent total height QtY/BoX 4370690 Black + 25 mm 60 mm 50 4370890 + 20 mm, - 5 mm 80 mm 4371090 + 20 mm, - 5 mm 100 mm Required product(s): productdescription 4370090 Leveler Head with Dowels Suggested product(s): productdescription 4370180 Allen Key Screwdriver 4 mm Red
Instruction Manual
StealthLock®, Keyless Invisible Security 1
Thank you for purchasing StealthLock® StealthLock® is an innovative solution for keyless invisible security. Using radio frequency technology, StealthLock® allows you to secure almost any wood cabinet door or drawer with little or no changes to the cabinet design.
StealthLock® is battery operated and works with a user established 4 to 8 digit code. Operation is simple: input your code and press lock or unlock. The Latch can operate any Receiver Latch within a 15 foot range which allows it to be placed anywhere, leaving no trace of visible hardware. In addition, the Latch can operate multiple Receiver Latches to secure an entire room or bank of cabinets.
StealthLock® is designed to install and program easily and offers:
Programmable user and supervisor codes
Programmable modes of operation
Programmable reset features
StealthLock® is recommended for use on cabinets made from:
Wood
Wood products
Phenolic resin
Glass
StealthLock® is NOT intended for:
Metal furnishings or cabinets
Exterior furnishings or cabinets
Applications where temperatures fall below 50° F or above 120° F
StealthLock® may be used in households to help protect minors from unsafe materials.
It is strongly recommended that all batteries used by the StealthLock® be replaced on an annual basis. Please mark this date on your calendars to insure replacement. In the event you have allowed the batteries to die, you will need to forcefully enter the cabinet. The StealthLock® strike plate is designed to shear away at 80lbs of force. A new strike plate will then be needed to operate the lock.
StealthLock®, Keyless Invisible Security 2
StealthLock®, Keyless Invisible Security 3
1 – TL-600 Installation Tool
1
–
TP-100 Transmitter Pad CR2032 Battery Included
SL-100
1 – SP-600 Cabinet Strike Plate Screws Included 2.500 .437
1 – RL-100 Receiver Latch Screws Included 6.785 3.375 .325
StealthLock® Contents 1.500
1.250
2.670 ACR0SS REAR TABS .350
Battery Installation – Receiver Latch
The Receiver Latch uses 4 AAA batteries that are expected to last 2 years in normal operation (4 open/close cycles per day).
Batteries should be replaced on an annual basis to insure continued reliability.
The LED will begin to blink after 5,500 operations to warn that batteries need to be replaced
While gripping the rear tabs, slide the battery housing in and up as shown
Slide the battery housing back until it is completely free of the Receiver Latch
Install four AAA batteries in the slots indicated on the back of the battery housing.
StealthLock®, Keyless Invisible Security 4
Battery Installation - Transmitter Pad
The Transmitter Pad uses a CR2032 battery that is expected to last 2 years in normal operation (4 open/close cycles per day).
Batteries should be replaced on an annual basis to insure continued reliability.
During initial installation, remove the red ribbon to activate the installed battery
The LED will begin to blink after 5,500 operations to warn that batteries need to be replaced
To replace the battery, insert a small flat blade screwdriver into the battery tray slot as shown
Rotate the Screwdrive up (clockwise) as shown to release the battery tray.
Replace old battery with fresh CR2032 making sure that the positive (+) side of the battery is facing down in the battery tray
Slide the battery tray back into the transmitter housing and snap into place
StealthLock®, Keyless Invisible Security 5
Installation Instructions – Receiver Latch
The StealthLock® is designed to operate within non-metallic cabinetry. Use with other materials may limit or prohibit operation of the lock. We recommend testing the lock if using in a material other than wood Batteries should be installed before installation.
The SL-100 StealthLock® kit is designed for mounting in cabinets with solid panel construction and full overlay doors. An INSTALLATION VIDEO and tips for mounting this kit in other cabinet types can be found at www.stealthlock.com
Step #1 - Position the Receiver Latch with strike plate and installation tool attached as shown. The front tabs on the installation tool should contact the front edge of the cabinet
Installation Tool Tabs
Front Edge of Cabinet
Step #2 - Screw the Receiver Latch in place using 2 of the #6 x ½” screws supplied, in the front side of the oval holes. If attaching to material less than ¾” thick, alternate fasteners may be required.
Start with Screws in Front Side of Oval Holes
StealthLock®, Keyless Invisible Security 6
Step #3 – Press the learn button on the Receiver Latch until the yellow LED lights to insure that the Latch is in the open position
Step #4 – Remove release paper from the back of the strike plate
Release Paper
Step #5 – Close door firmly and open it again. The strike plate will become affixed to the door in the proper mounting position. Remove and discard red installation tool
Step #6 - Screw the strike plate in place using 2 of the #6 x ½” screws supplied. If attaching to material less than ¾” thick, alternate fasteners may be required.
Step #7 – Check the fit after any bumpers are installed. Door should latch into the Receiver Latch and still have a little free play. Adjust Receiver Latch forward on oval holes as required.
Finish by installing the remaining screws at the front of the Receiver Latch
StealthLock®, Keyless Invisible Security 7
Learn Button
Installation Instructions – Transmitter Pad
The Transmitter Pad has a functional range of 15 feet from the Receiver Latch and can be mounted virtually anywhere on any non-metallic panel. To mount, simply remove the release paper from the tape on the back side of the Transmitter Pad, and press into place.
Suggested mounting areas
Cabinet door face or drawer face
Wall above switch plate
Inside unlocked cabinet door or drawer to be hidden
Remove release paper from tape
StealthLock®, Keyless Invisible Security 8
Programming – Introduction
StealthLock® is very easy to use and operate. Once installed, the user enters the user code (factory default 0000) and presses Lock to lock the cabinet. To unlock the cabinet, the user enters the user code and presses Unlock and the cabinet will open.
StealthLock® is fully programmable allowing the user or supervisor the ability to change codes, modes, and restore lock settings. While the StealthLock® is easy to program, we highly recommend reading the complete programming instructions prior to making any changes. Remember to keep track of any changes made in a secure location.
Key locations and indicator lights referenced in the programming instructions are shown below.
RL-100 Receiver Latch
Yellow and Green LED Indicator
Learn Button – Use pen tip or paper clip to depress
StealthLock®, Keyless Invisible Security 9
Programming – Introduction
TP-100 Transmitter Pad
Please note the following:
StealthLock® will reset to an unlocked position whenever the learn button is pressed.
Only one Transmitter Pad should be used for programming in a given area at any one time. The StealthLock® is a radio frequency device and the use of multiple Transmitter Pads in the same area may result in interference and improper programming.
After pressing Lock or Unlock, the Green LED on the Transmitter Pad will light for about 2 seconds indicating that a transmission is in progress
While the Green LED on the Transmitter Pad is lit, the keypad will not respond to any other entries until the transmission is completed
If the Green LED on the Transmitter Pad flashes rapidly after pressing Lock or Unlock, this indicates that an improper code has been entered. Codes must always be 4 to 8 digits in length.
If the LED indicator on the Receiver Latch flashes Green/Yellow, this indicates that an improper code as been received. Start the learning function over taking care to enter the correct codes.
StealthLock®, Keyless Invisible Security 10
Unlock Button
Green LED Indicator
Lock Button
Programming the User Code
Use these steps to change your current user code The factory default code is 0000 User codes must be 4 to 8 digits in length. To view a video of these steps, go to www.StealthLock.com Note that the user code can not be changed if the Receiver Latch has been set to Single Use Mode.
There is a 60 second programming time limit to each step. If you time out or make an error, programming will end and you will need to restart from step 1.
1. We suggest reading through the instructions prior to beginning programming
2. Press and hold the Receiver Latch learn button until the yellow LED light begins a one blink pattern, then release
3. Using the Transmitter Pad enter the current user code and press the Unlock button
4. Wait for green light on Transmitter Pad to turn off then enter the new user code and press the Lock button
5. Wait for green light on Transmitter Pad to turn off then re-enter the new user code and press the Lock button to secure code
6. If successful, the green LED light on the Receiver Latch will stay illuminated for 3 seconds
7. Once the green LED light has turned off, the Receiver Latch will automatically exit the learn mode
8. Test lock function with new code
9. We recommend writing down your new code in the back of these instructions and storing in a safe area
StealthLock®, Keyless Invisible Security 11
Programming the Supervisor Code
Use these steps to change the current supervisor code. The supervisor code allows the owner of the StealthLock® to overwrite the user code and change operational modes. The factory default supervisor code is 071856 It is highly recommended that the supervisor code be changed. Supervisor codes must be 4 to 8 digits in length. To view a video of these steps, go to www.stealthlock.com .
There is a 60 second programming time limit to each step. If you time out or make an error, programming will end and you will need to restart from step 1.
1. We suggest reading through instructions prior to beginning programming.
2. Press and hold the Receiver Latch learn button until the yellow LED begins a two blink pattern
3. Enter the current supervisor code using the Transmitter Pad and press the Unlock button
4. Wait for green light on the Transmitter Pad to turn off then enter the new supervisor code and press the Lock button
5. Wait for green light on the Transmitter Pad to turn off then re-enter your new supervisor code and press the Lock button to secure code
6. If successful, the green LED light on the Receiver Latch will stay illuminated for 3 seconds
7. Once the green LED light has turned off, the Receiver Latch will automatically exit the learn mode
8. Test lock function with new code
9. We recommend writing down your new code in the back of these instructions and storing in a safe area The supervisor code is not resettable if it has been forgotten.
StealthLock®, Keyless Invisible Security 12
StealthLock® features several modes of operation and reset ability. These functions can be changed using the following instructions by users who have rights to the supervisor code. Modes and reset can only be modified with knowledge of the supervisor code.
Programming Single Use Mode / Non Single Mode
Non Single Mode allows the user to set the user code to be used by a single person only. Single Use Mode allows for a revolving user code so the lock maybe used by multiple people without having to reprogram the Receiver Latch each time.
There is a 60 second programming time limit to each step. If you time out or make an error, programming will end and you will need to restart from step 1.
1. We suggest reading through instructions prior to beginning programming
2. Press and hold the Receiver Latch learn button until the yellow LED begins a three blink pattern
3. Enter the Supervisor pin code and press the Unlock button
Then either
a. Set Single Use Mode, enter 1111 and press the Lock button Note that this will cancel self lock mode if it has been set Or
b. Set Non Single Use Mode, enter 1111 and press the Unlock Note that the user code resets to 0000 when Single Use Mode is exited
4. If successful the green LED will flash twice on the Receiver Latch
5. Continue programming or enter 9999 followed by pressing the Lock button to exit Learn Mode
6. Test lock function for proper operation
StealthLock®, Keyless Invisible Security 13
Programming Self Lock Mode / Passage Mode
Self Lock Mode automatically relocks the Receiver Latch after pressing the unlock button when a valid user or supervisor code is presented. The delay time before relocking the Receiver Latch can be set between 2 and 60 seconds. Passage Mode keeps the Receiver Latch in an unlocked position after unlocking.
There is a 60 second programming time limit to each step. If you time out or make an error, programming will end and you will need to restart from step 1.
1. We suggest reading through instructions prior to beginning programming
2. Press and hold the Receiver Latch learn button until the yellow LED begins a three blink pattern
3. Enter the Supervisor pin code and press the Unlock button
Then either
a. Set Self Lock, enter 2222XX and press the Lock button Note that this command is ignored if Single Use mode is set XX represents the number of seconds of delay time before relocking For example entering 222215 would result in a 15 second delay Or
b. Set Passage Mode, enter 2222 and press the Unlock button
4. If successful the green LED will flash twice on the Receiver Latch
5. Continue programming or enter 9999 followed by pressing the Lock button to exit Learn Mode
6. Test lock function for proper operation
StealthLock®, Keyless Invisible Security 14
Programming Learn Disable / Learn Enable
Learn Disable / Learn Enable Mode allows the supervisor to either allow or not allow a user to program a new user code. In Learn Disable Mode, only the users with knowledge of the supervisor code can make any programming changes.
There is a 60 second programming time limit to each step. If you time out or make an error, programming will end and you will need to restart from step 1.
1. We suggest reading through instructions prior to beginning programming
2. Press and hold the Receiver Latch learn button until the yellow LED begins a three blink pattern
3. Enter the Supervisor pin code and press the Unlock button
Then either
a. Set Learn Disable, enter 3333 and press the Lock button Or
b. Set Learn Enable, enter 3333 and press the Unlock button
4. If successful the green LED will flash twice on the Receiver Latch
5. Continue programming or enter 9999 followed by pressing the Lock button to exit Learn Mode
6. Test lock function for new mode operation. If Learn Disable has been set, the Receiver Latch should automatically go to a three blink pattern when the learn button is pushed and held.
StealthLock®, Keyless Invisible Security 15
Reset Factory Default Settings
This feature returns the lock to its original factory settings. This will place the Receiver Latch into a Non Single Use Mode, Passage Mode, and Learn Enable Mode. It does not reset the user or supervisor code
There is a 60 second programming time limit to each step. If you time out or make an error, programming will end and you will need to restart from step 1.
1. We suggest reading through instructions prior to beginning programming
2. Press and hold the Receiver Latch learn button until the yellow LED begins a three blink pattern
3. Enter the Supervisor pin code and press the Unlock button
4. Enter 4444 and press the Lock button
5. If successful the green LED will flash twice on the Receiver Latch. Note that if Single Use mode was exited, the user pin code will default to 0000
6. Continue programming or enter 9999 followed by pressing the Lock button to exit Learn Mode
7. Test lock function to make sure default settings are restored
StealthLock®, Keyless Invisible Security 16
Clear User Pin Code
This feature returns the user code back the factory default setting of 0000. It does not reset any other mode or feature of the lock.
There is a 60 second programming time limit to each step. If you time out or make an error, programming will end and you will need to restart from step 1.
1. We suggest reading through instructions prior to beginning programming
2. Press and hold the Receiver Latch learn button until the yellow LED begins a three blink pattern
3. Enter the Supervisor pin code and press the Unlock button
4. Enter 8888 and press the Lock button
5. If successful the green LED will flash twice on the Receiver Latch
6. Continue programming or enter 9999 followed by pressing the Lock button to exit Learn Mode
7. Test lock function to make sure user default setting is restored. Lock can now be programmed with a new user code
StealthLock®, Keyless Invisible Security 17
Auxiliary Power
If desired, the StealthLock® Receiver Latch may be connected to 120 VAC power using the optional RL-AP1 Power Supply
Power Port
RL-APC Power Cords
Up to 10 Receiver Latches may be powered from the same Power Supply using the optional RL-APC Power Cords as shown
RL-AP1 Power Supply
RL-AP1 Power Supply (Includes 5-1/2 foot cord) cord
RL-APC-3 Power Cord – 3 foot
RL-APC-5 Power Cord – 5 foot
RL-APC-10 Power Cord – 10 foot
StealthLock®, Keyless Invisible Security 18
Transmitter Pad Mounting Accessories
MP-700 Mounting Plate
Satin Nickel Finish
Allows mounting to material
5/8” – 7/8” Thick
Mounting screws and template included
MP-700-WM Mounting Plate
Satin Nickel Finish
Allows mounting to any flat surface or wall
Mounting Plate screws included
Wall mounting screws not included
StealthLock®, Keyless Invisible Security 19
Regulatory Information
The user is cautioned that changes or modifications not expressly approved by CompX Timberline could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
StealthLock®, Keyless Invisible Security 20
IS-600-K Copyright 2016 © CompX Security Products
StealthLock Installation Template for Overlay Door/Drawer Applications
SCALE: 1:1
DIMENSIONS: INCHES/MM
REV
2.500 63.5
172.3 2.125 54
6.785 OVERALL LENGTH OF RECEIVER LATCH
5.3
.210 DISTANCE FROM FRONT EDGE OF CABINET SIDE TO FACE OF RECEIVER LATCH
2.829 71.9 1.535 39 1.085 27.6
.030 GAP BETWEEN CABINET EDGE AND DOOR OR DRAWER FRONT
0.8
DOOR OR DRAWER FACE
BACK OF DOOR OR DRAWER FACE
FRONT EDGE OF CABINET SIDE
B - 12/03/12
POSITION MOUNTING SCREWS AT FRONT SIDE OF OVAL HOLES TO ALLOW FORWARD ADJUSTABILITY