15' [4.57m]
110'-7" [33.69m]
34'-5" [10.49m]
25' [7.63m]
25'-014" [7.63m]
TREES TO BE REMOVED
28'-4" [8.63m]
160'-0 1/2"
134'-7" [41.01m]
E.EL. 41.51 P.EL. 40.13
P.EL. 40.75 E.EL. 40.75
BUILDING - INTERIOR DESIGNERS
PROPOSED SINGLE FAMILY DWELLING 13049 COULTHARD ROAD SURREY ROOF RIDGE: 50.85 MEAN ROOF: 49.65 U/S CEILING: 48.45 SECOND FLOOR: 45.71 MAIN FLOOR: 42.30 EXISTING AVG. GRADE 40.09 BASEMENT: 39.19
TO BE REMOVED
P.EL. 38.83 E.EL. 38.83 49' [14.94m]
MIN 2% DRAIN WATER SLOPE STORM LVL.: IC 36.91
P.EL. 38.91 E.EL. 38.91
TO BE REMOVED
97'-7" [29.75m]
62'-5" [19.02m]
15' [4.57m]
25'-1" [7.64m]
TO BE REMOVED
TREES TO BE REMOVED
MIN 7.2% DRAIN WATER SLOPE
115'-5" [35.17m]
UDC DESIGN CENTER LTD
P.EL. 40.70 E.EL. 41.87
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
SATVINDER MAHENDRU PROJECT:
CIVIC ADDRESS: 13049 COULTHARD ROAD SURREY, BC LEGAL DESCRIPTION: LOT #1 DISTRICT LOT 51 AND 709 GROUP 2 NEW WESTINSTER DISTRICT PLAN 68938
SITE PLAN
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1279
DATE:
AUG. 2017
FILE NO.
SCALE:
1/16"=1'-0"
V01
SHEET NO:
A 1/6
SPECIFICATIONS AND GENERAL NOTES:
SECTION 07200
30'-8" 17'-5"
6010RS
12'-6" 5068
5030LS
107'-4"
50'-0"
22'-9"
section B-B
5030LS
6'-10"
21068
2668
6030RS
21068
21068
Elongated Toilet
5030LS
5030LS
6'-0"
Double Door Refrigerator 1
4068
section A-A
NOTES FOR ROOF SPACE VENTILATION
5068
5030LS
A-A
5'-2"
A-A
8'-0"
Narrow Shower
UP
Elongated Toilet
2630LS
Tub-Shower 2
21068
26'-8"
6'-0"
PROVIDE MIN. 2-1/2" CLEARANCE BETWEEN ROOF SHEATHING AND INSULATION. PROVIDE MIN. 1" CLEARANCE BETWEEN TOP OF ROOF JOIST AND INSULATION. VENTILATE ATTIC SPACES TO 1/300 OF INSULATED CEILING AREA. ROOF VENTS MUST BE UNIFORMLY DISTRIBUTED WITH A MIN. OF 25% IN EAVES AND 25% IN ROOF TOP. PROVIDE ATTIC ACCESS OF 1'-8" X 2'-4" AND WEATHER-STRIP HATCH.
Narrow Shower
3068
3'-3"
3. 4. 5. 6. 7.
2668 5030LS
UNIFORMLY DISTRIBUTE VENTILATION TO FLAT AND VAULTED ROOFS TO 1/150 OF INSULATED CEILING AREA. PROVIDE 2x2 CROSS PURLINS TO FLAT, VAULTED CEILINGS AND DECKS OVER LIVING AREAS.
4068
1. 2.
6'-3"
21068
21068
6030RS 3068
8130RS
6030RS
4016RS
2012 BCBC SECTION 9.36 REQUIREMENTS B-B
EXECUTION: EXTEND BOARDS A MINIMUM OF 24" (600MM) BELOW GRADE. 1. SERVICE WATER HEATING SYSTEM SHALL COMPLY WITH 2012 BCBC 9.36.4 2 THE DESIGN AND INSTALLATION OF THE HEATING , VENTILATION & AIR CONDITIONING SYSTEM SHALL COMPLY WITH INSTALL PERIMETER INSULATION USING MECHANICAL FASTENERS OR ADHESIVE. BUTT JOINT TIGHTLY, OFFSET REQUIREMENTS OF 2012 BCBC SECTION 9.36.3. HORIZONTAL AND VERTICAL JOINTS. USE LARGEST POSSIBLE SHEETS TO REDUCE NUMBER OF JOINTS. DO NOT 3. MECHANICAL , ELECTRICAL AND PLUMBING COMPONENTS PLACED WITHIN AN EXTERIOR WALL MUST BE INSULATED BEHIND TO THE EFFECTIVE THERMAL RESISTANCE SPECIFICATION SECTION 9.36.2.6. & 9.36.2.8. USE CHIPPED OR CRACKED INSULATION BOARDS. 4. CONSTRUCTION OF AIR BARRIER DETAILS SHALL COMPLY WITH 2012 BCBC 9.36.2.10. PROTECT INSULATION WITH PRESSURE TREATED PLYWOOD AND PRE FINISHED METAL CAP FLASHINGS. 5. THE LEAKAGE OF AIR INTO AND OUT OF CONDITIONED SPACES SHALL BE CONTROLLED BY CONSTRUCTING A INSULATION IN CAVITY WALLS: APPLY INSULATION IN CAVITY WALLS USING IMPALE TYPE CLIPS. FASTEN BOARDS CONTINUOUS AIR BARRIER SYSTEM AS SPECIFIED BCBC 9.36.2.9. 6. WALLS AND CEILINGS SEPARATING CONDITIONED SPACE FROM ATTACHED GARAGE ARE TO COMPLY WITH EFFECTIVE WITH A MINIMUM OF (4) FASTENERS PER 24" X 48" (600MM X 1200MM) BOARD. THERMAL RESISTANCE MINIMUM AS SPECIFIED IN SECTION 9.36.2.6. & 9.36.2.8. (EVEN IF GARAGE IS HEATED AND INSULATED) BATT INSULATION: INSTALL FULL WIDTH AND LENGTH BETWEEN STUDS AND FRAMING MEMBERS TO FIT SNUGLY WITHOUT BUCKLING, CREASING OR CRUSHING AS PER REQUIREMENTS OF BCBC 2012 SECTION 9.36.2.5. IN WALLS, INSTALL LOWER BATT FIRST; UPPER BUTT INSTALLED TO BUTT WITH THE FIRST AND ANY EXTRA LENGTH OF INSULATION TRIMMED AT TOP AS PER REQUIREMENTS OF BCBC 2012 SECTION 9.36.2.5. FIT INSULATION TIGHT TO ELECTRICAL BOXES, PLUMBING AND HEATING PIPES AND DUCTS, AROUND EXTERIOR DOORS AND WINDOWS AND OTHER PROTRUSIONS AS PER REQUIREMENTS OF BCBC 2012 SECTION 9.36.2.5. INSTALL INSULATION IN CONTINUOUS CONTACT WITH INTERIOR SHEATING AS PER REQUIREMENTS OF BCBC 2012 SECTION 9.36.2.5. ACCESS HATCHES: INSULATE ACCESS HATCHES TO THE SAME R VALUE AS THE ASSEMBLY IN WHICH THEY OCCUR.
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
13'-3"
13'-6" 22'-4" 3'-6" 16'-4" 3'-6" 1'-6" 4'-3"
5068
9'-9"
ASPHALT SHINGLE AND CEDAR SHINGLE/SHAKES IF APPLICABLE PRODUCTS: ASPHALT SHINGLES: ACCEPTABLE MATERIALS AS LISTED IN THE RCABC ROOFING PRACTICES MANUAL, TAB 2" ACCEPTABLE MATERIALS LIST", LATEST EDITION. SHINGLE MATERIALS MAY BE ORGANIC OR FIBERGLAS CORE PRODUCT. FASTENER: NAILS MUST BE LARGE HEAD, CORROSION RESISTANT, (ELECTRO-GALVANIZED, HOT DIPPED GALVANIZED, ALUMINUM), ROOFING NAILS. METAL FLASHING: BASE AND COUNTER FLASHING AND COPING METAL TO BE SHEET STEEL, MINIMUM 26 GAUGE, GALVANIZED TO ASTM A525,ZF275 COATING, PRE FINISHED WITH STELCOLOUR 5000 SERIES PAINT FINISH. STEP FINISHING MUST BE 26 GAUGE IN ACCORDANCE WITH RCABC REQUIREMENTS. ACCESSORIES: INSTALL ZINC. STRIPS TO ASPHALT SHINGLE AT ALL RIDGE LOCATIONS. INSTALL ZINC STRIP MUST BE 2" (50MM) EXPOSED TO THE WEATHER. EAVES PROTECTION: SELF ADHESIVE RUBBERIZED ASPHALT SHEET INSTALLED TO BUILDING CODE REQUIREMENTS. ACCEPTABLE MATERIALS AS LISTED IN RCABC ROOFING MANUAL TAB 2" ACCEPTABLE MATERIAL LIST", LATEST EDITION. UNDERLAY: 1 PLY OF No. 15 NON PERFORATED ASPHALT FELT TO CSA A123.3M1979. EXECUTION: ASPHALT SHINGLE ROOFING MUST BE INSTALLED ACCORD. TO RCABC,STR-LS FOR LOW SLOPE ROOFS. INSTALL UNDERLAY ON ALL ROOF DECKS WHERE ASPHALT SHINGLES OF ANY TYPE ARE TO BE INSTALLED. UNDERLAY TO BE MINIMUM 1 PLY OF No. 15 NON PERFORATED FELT, LAPPED MINIMUM 3"(75MM) OR THE SPECIFIC SHINGLE MANUFATURER'S. RECOMMENDED UNDERLAY. THIS UNDERLAY IS ADDITIONAL TO ANY MATERIAL USED FOR EAVES PROTECTION AND SHOULD BE LAPPED OVER THE LEADING (TOP) EDGE OF THE EAVES PROTECTION. PROVIDE SLOPE TO DRAIN IN ALL GUTTER APPLICATIONS. WATERPROOF LINING FOR "HIDDEN" OR "INBOARD" OR PLY FULLY TORCHED TO FIRST PLY. "BUILT-IN" TYPE GUTTERS MUST BE FULLY ADHERED 2 PLY MODIFIED BITUMEN SHEETS AND MUST THE BASE SHEET INSTALLED UP THE SLOPE OF THE ROOF A MINIMUM OF 18" (450MM) HIGHER THAN TOP OF OUTBOARD SIDE ELEVATION OF THE GUTTER. THE CAP SHEET IS TO PROVIDE UV PROTECTION AND MUST BE INSTALLED IN ALL AREAS EXPOSED TO U.V. USE SELF ADHERING BASE SHEET WHENEVER POSSIBLE WITH SECOND UV PROTECTIVE ENSURE DRAINS DISCHARGE INTO DOWN SPOTS THAT ARE KEPT ABOVE FREEZING.
71130RS
FASCIA WINDOW TRIM, TRIM: INSTALL FASCIAS AND TRIMS IN LONGEST PRACTICAL LENGTHS, END JOINTS TO BE CUT IN 45 DEGREES AND LAPPED. FASTEN WITH HOT DIPPED GALVANIZED CASING NAILS AND COUNTERSINK. WOOD SIDING: INSTALL WALL CAVITY IF REQUIRED BY WALL DESIGN. USE LONGEST POSSIBLE LENGTHS TO MINIMIZE END JOINTS. INSTALL SIDING USING GALVANIZED SIDING OR CASING NAILS WITH RING OR SPRING SHANKS. DO NOT NAIL THROUGH OVERLAPPING PIECES. NAILS MUST BE LONG ENOUGH THAT THE NAIL PENETRATES THE FRAMING AT LEAST 1 1/4" (31.7MM). LAP BEVEL SIDING A MINIMUM OF 1" (25.4MM). SHIM BOTTOM EDGE OF SIDING TO PROVIDE A 1/8" (3MM) GAP BETWEEN IT AND THE SIDING BELOW. USE SOLID TRIMS AT INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS. USE SOLID WOOD TRIMS AT THE INSIDE AND OUTSIDE CORNERS. BUTT SIDING INTO TRIMS.
SECTION 07300
2'-3"
LUMBER GRADES: AS SHOWN ON THE DRAWINGS AND / OR ACCORDING TO NLGA STANDARD GRADING RULES FOR CANADIAN LUMBER, MAXIMUM MOISTURE CONTENT 19%. ROOF SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, METAL "H" CLIPS TO SUPPORT EDGES: 1/2" (12.5MM) FOR 16" (400MM) O/C SUPPORT; 5/8" (15.9MM) FOR 24" (600MM) O/C SUPPORT. INTERIOR FLOOR SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. USE TO PLYWOOD WHERE REQUIRED BY STRUCTURAL DESIGN. FLOOR UNDERLAY: THREE PLY, 11/32" (8.5MM) THICK, SPRUCE PLYWOOD WITH THE FINISH FACE DOUBLE SANDED AND THE BACK FACE SLIGHTLY SANDED. THE CONTRACTOR MUST CONFIRM PRIOR TO INSTALLATION THE FLOORING UNDERLAY THAT IT IS ACCEPTABLE TO THE RESILIENT FLOORING MANUFACTURER. EXTERIOR DECK SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR, T&G. USE SELECT TIGHT FACE PLYWOOD UNDER PVC DECK WATERPROOFING. EXTERIOR WALL SHEATHING: PLYWOOD, SHEATHING GRADE, DOUGLAS FIR OR SPRUCE. WOOD SIDING IF REQUIRED IN DESIGN: WESTERN RED CEDAR, KILN DRIED, SELECTED KNOTTY GRADE, BEVELED OR CHANNEL PATTERN, PRE-STAINED. FIBBER CEMENT EXTERIOR SIDING: NON COMBUSTIBLE FIBBER REINFORCED CEMENT HORIZONTAL SIDING. EXTERIOR FASCIAS AND TRIM: No.2, S-P-F, TEXTURED (COMBED) FINISH, PRE PRIMED FOR SOLID COLOR STAIN, NOT LESS THAN 2" (50MM) NOMINAL THICKNESS. SILL GASKET: CLOSED CELL POLYETHYLENE FOAM. GRAB BAR BLOCKING: 2" X 10" (38MM X 235MM). WOOD PRESERVATIVES: WOOD IN CONTACT WITH CONCRETE, MASONRY, AT ROOF UPSTANDS IN FLAT ROOFS, PLANTERS, HEAVY TIMBER CONSTRUCTION, FENCE POSTS AND CAVITY FURRING: PRESSURE TREATED MINIMUM 0.40 LB/FT2 TO CSA 080-M89, CLEAR, WATER BORNE, CHROMATE COPPER ARSENATE PRESERVERS BUREAU (CWPB) STAMPS. BOTTOM PLATE OF FRAME WALLS WITH SILL GASKETS DO NOT REQUIRE PRESSURE TREATING. USE HEM-FIR OR PINE INCISED LUMBER FOR TREATMENT. TREAT CUT SURFACES WITH TWO BRUSH OF COPPER NAPTHANATE PRESERVATIVE. EXECUTION: EXTERIOR WALL SILL PLATES: SET EXTERIOR WALL SILL PLATES ON FULL WIDTH STRIP OF
13'-2"
2668
2'-3"
ROUGH CARPENTRY
11'-10"
5068
3'-6"
SECTION 06100
8'-5"
4'-0"
13 - PROVIDE FLASHING BETWEEN HORIZONTAL INTERSECTION OF DIFFERING WALL FINISHES.
75'-10"
8'-0"
DWELLING SECURITY AS PER BCBC 2012 # 9.6.8
AIR BARRIER / SHEATHING MEMBRANE PRODUCT: TWO LAYERS OF 30 MINUTE ASPHALT SATURATED BUILDING PAPER CONFIRMING TO CAN-51.32M77 AND TO U.S. UUB-790a. EXECUTION: AIR BARRIER MEMBRANES MUST BE APPLIED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS AT ALL THE LOCATION IN THE EXTERIOR OF THE BUILDING ENVELOPE WHERE AIR IS FREE TO INFILTRATE THROUGH JOINTS IN COMPONENTS OF THE ASSEMBLIES AND AT JUNCTIONS WITH DISSIMILAR MATERIALS, CHANGES IN PLANE AND AT THE ROOF INSTALL SHEATHING MEMBRANE OVER EXTERIOR SHEATING. INSTALL ONE (1) LAYER OF ASPHALT SATURATED BUILDING PAPER HORIZONTALLY IN SUCCESSIVE STRIPS BEGINNING 2" (50MM) BELOW THE LOWEST POINT OF THE WALL FRAMING AND PROGRESSING UPWARDS WITH EACH SUCCEEDING SHEET. OVERLAP UPPER SHEET OVER LOWER SHEET A MINIMUM OF 4" (100MM) SO THAT LAPS ARE ARRANGED TO SHED WATER. END LAPS MUST HAVE A MINIMUM 12" (300MM) OVERLAP. STAGGER VERTICAL LAPS A MINIMUM OF 48" (1200MM). RETURN SHEET OVER FLASHINGS.
6'-8"
11- PRIOR TO FRAMING AND INSPECTION SUBMIT MECHANICAL VENTILATION/AIR CONDITIONING AND LETTER OF SUPERVISION B PROF.ENG.OR CERTIFIED H.R.A.I OR HVC TECHNICIAN.
3010
6'-4"
ENGINEERED ROOF TRUSS DESIGN REQUIRED PRIOR TO INSTALLATION. PROVIDE 8" CLEARANCE BETWEEN GRADE AND SIDING.
SECTION 07270
1'-10"
WATERPROOF WALLBOARD REQUIRED AS TILE BASE AROUND TUBS AND SHOWERS AS PER BCBC 9.29.10.4. CEILING AND WALLS TO HAVE 6 mil U.V.POLY FULLY CAULKED AS PER 2012 BCBC 9.25.2.3 5/8" DRYWALL REQUIRED TO CEILING MEMBERS AT 24" O.C. AS PER 2012 BCBC 9.29.5.3. PROVIDE 5" GRAVEL AS PER BCBC 9.14.4.2 AND 6 mil U.V.POLY AS PER 2012 BCBC 9.13.6 UNDER SLAB A BOND BREAKING MATERIAL IS REQUIRED BETWEEN FOUNDATION AND SLABS DOORS BETWEEN GARAGE AND DWELLING TO BE A SOLID CORE, SELF CLOSING, WEATHER STRIPPED DOOR AS PER 2012 BCBC 9.10.13.15. THICKEN SLAB AT GARAGE ENTRY AS PER STRUCTURAL DRAWINGS. HEATING SYSTEM IS RADIANT HEAT FOR ALL FLOORS
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
GENERAL NOTES
35'-9"
SOFFITS: VENTED HARDISOFFIT
23'-4"
WINDOW TRIMS: HARDITRIM
20'-0"
EXTERIOR WINDOWS: ALUMINUM CLADDED WOOD FRAME OR VINYL FRAME
VAPOR BARRIER / VAPOR RETARDER TO BE INSTALLED AS PER REQUIREMENTS OF BCBC 2012 SECTION 9.36.2.9 & 9.36.2.10. PRODUCT: MATERIAL TO CONFORM TO CAN2-51.33-M80, TYPE II, 6 MIL IN WALLS. EXECUTION: APPLY VAPOR BARRIER TO WARM SIDE (INTERIOR SIDE) OF INSULATED WALLS. INSTALL VAPOR BARRIER TO PROTECT THE ENTIRE WALL SURFACE, INCLUDING FRAMING MEMBERS. APPLY VAPOR BARRIER HORIZONTALLY TO WALLS. LAP JOINTS MINIMUM OF 4" (100MM). SEAL TO FRAMING WITH ADHESIVE OR PRESSURE SENSITIVE TYPE. SEAL VAPOR BARRIER RETARDER TO PENETRATIONS.
21'-0"
15'-6"
2. EXTERIOR WALL FINISH: FINISH STUCCO , NATURAL OR CULTURED STONE
24'-0" 3'-0"
13'-0"
ROOF FINISH: ASPHALT SHINGLE
SECTION 07200
107'-8"
EXTERIOR BUILDING FINISH MATERIALS:
B-B
CLIENT:
6'-6"
6'-6"
8'-0"
9'-4"
CIVIC ADDRESS: 13049 COULTHARD ROAD SURREY, BC LEGAL DESCRIPTION: LOT #1 DISTRICT LOT 51 AND 709 GROUP 2 NEW WESTINSTER DISTRICT PLAN 68938
10'-7"
9'-0"
40'-11"
7'-1"
3'-3"
13'-2"
34'-1" 75'-0"
SHEET TITLE:
SATVINDER MAHENDRU PROJECT:
1'-8"
BASEMENT FLOOR
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1279
DATE:
AUG. 2017
FILE NO.
SCALE:
1/8" = 1'-0"
V01
SHEET NO:
A 2/6
72'-10" 18'-5"
21'-0" 9'-0"
33'-5"
7'-4"
12'-0"
B-B
13'-3"
3068
3068
9080
12'-9"
6040RS
B-B
35'-9"
69'-6"
43'-2"
2'-9"
2'-4"
12'-8"
4'-0"
5'-4"
8'-5"
2'-1"
2'-5"
11'-2"
23'-0"
17'-5"
9080
8'-1"
10'-2"
11'-8"
12'-6"
3068 4016RS
21068
6068
62'-7" 11'-11"
2668
5068
A-A
21068 3068
21068
4'-1"
8'-0"
14'-9"
21068
3040RS
Elongated Toilet
3040RS
3'-3"
4028RS
21068
7'-0"
13'-7"
3'-6"
A-A
8'-0"
5'-6" Elongated Toilet
3040RS
12'-4"
4'-6"
8'-8"
6040RS
4'-8"
2'-6"
DN 19R @7"
6060RS
63'-0"
3'-5"
7'-8"
6'-10"
15'-0" 6'-4"
7'-0"
6'-9"
4030RS
107'-4"
68
50
31040RS
6'-6"
10'-2"
22'-9"
13'-9"
5068
section B-B
107'-8"
8'-6"
9'-10"
11'-2"
Single Basin Laundry Sink Dryer (curved)
68 26
6040RS
Dryer (curved)
22'-4"
36'-0"
9'-6"
510110RS
42'-0"
18'-0"
4'-6" 6060RS
3068
21068
7'-2"
24'-10"
21068
2668
6'-2"
6'-8"
2668
3'-10"
2'-6"
Rect (medium) [48]
3068
11'-8"
Corner
4040RS
21068
2080FX
A-AA-A
SMOKE ALARM & CARBON MONOXIDE (CO) ALARM
9'-2"
6068 8068
8'-0"
3'-7"
10'-0"
26'-8" 11'-5" 3'-3"
3'-7"
2'-0" 4'-9"
3'-1"
6'-8"
6'-8"
4'-6"
17'-10"
21'-4"
13'-2" 20'-11"
60'-2"
2'-7"
3840RS
12060RS
6'-8"
6'-5" 21'-0"
10068
6'-4"
B-B 6'-7"
3'-3"
6040RS 6040RS 11960RS
12060RS
13'-0" B-B
11960RS
21068
21068
26'-8"
8068
11960RS
fridge
6040RS
3'-9"
S CO
1'-10"
8'-0"
68
3268
6'-7"
11'-8" 5068
60
26'-9"
21068
3'-6" 7'-6"
Corner
section A-A
6068
1'-8"
shower
11960RS
Double Door Refrigerator 2
A-A
21068
12'-11"
21068
Elongated Toilet
1'-8" 12'-7"
4030RS
6'-5"
6030RS
21'-0"
DN
21068
8'-1"
6068
UP
6016FX 6080
18'-1"
12'-0"
2080FX
21068
47'-0"
BUILDING - INTERIOR DESIGNERS
4040RS
9080
4040RS
68 50
UDC DESIGN CENTER LTD
33'-5"
36'-1"
8'-0"
6'-9"
6'-6"
5'-1"
10'-5"
40'-11"
10'-5"
13'-2"
7'-8"
41'-8" 82'-8"
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
SATVINDER MAHENDRU PROJECT:
CIVIC ADDRESS: 13049 COULTHARD ROAD SURREY, BC LEGAL DESCRIPTION: LOT #1 DISTRICT LOT 51 AND 709 GROUP 2 NEW WESTINSTER DISTRICT PLAN 68938
MAIN AND TOP FLOOR
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1279
DATE:
AUG. 2017
FILE NO.
SCALE:
1/8" = 1'-0"
V01
SHEET NO:
A 3/6
MEAN ROOF LVL. 49.65
U/S CEILING LVL. 48.45
3'-1118" [1.20m] 3'-1118" [1.20m]
ROOF RIDGE LVL. 50.85
3'-1118" [1.20m] 3'-1118" [1.20m]
ROOF RIDGE LVL. 50.85
MEAN ROOF LVL. 49.65 1
U/S CEILING LVL. 48.45
12
5
2
9' [2.74m]
9' [2.74m]
3 510110RS
4 11960RS
6040RS 24 11960RS
11960RS 70.5
6016FX
2080FX
4016RS
9080
9080
6040RS
9080
2080FX
6040RS 6080
6
12060RS
5
11'-23 8" [3.41m]
29'-3" [8.90m]
SECOND FLOOR LVL. 45.71
11'-23 8" [3.41m]
SECOND FLOOR LVL. 45.71
29'-3" [8.90m]
70.5
6040RS
6040RS
24
24
12060RS
11960RS 72
8
5030LS
5030LS
E.EL.: 40.28
6030RS
AVE. GRADE. LVL. 40.09
71130RS
P.EL. 38.91 E.EL. 38.91
10'-23 8" [3.11m]
P.EL. 41.65 E.EL. 41.87
5'-1" [1.55m]
5'-1" [1.55m]
MAIN FL. LVL. 41.65
BSMT. FL. LVL. 38.54
4016RS 8130RS
6030RS 24
6030RS
18
3068
BSMT. FL. LVL. 38.54
P.EL. 41.46 E.EL. 38.91
LIST OF MATERIALS
6
18
3068
P.EL. 41.46 E.EL. 38.83
FRONT ELEVATION
RIGHT ELEVATION
SCALE:1/8"-1'
SCALE:1/8"-1' 1. 2. 3. 4. 5. 6. 7. 8.
ASPHALT SHINGLE 40 YRS - IKO CAMBRIDGE, DUAL BLACK BUILT-IN GUTTER - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT 1 x 8 ON 2" X 10" FASCIA BOARD 1" X 4" WOODEN TRIM STUCCO ALUMINUM FRAMED WINDOW AND PATIO DOOR WOODEN EXTERIOR DOOR STONE
U/S CEILING LVL. 48.45
9' [2.74m]
U/S CEILING LVL. 48.45
MEAN ROOF LVL. 49.65
31040RS
4030RS
12
9' [2.74m]
MEAN ROOF LVL. 49.65
3'-1118" [1.20m] 3'-1118" [1.20m]
ROOF RIDGE LVL. 50.85
3'-1118" [1.20m] 3'-1118" [1.20m]
ROOF RIDGE LVL. 50.85
4040RS
3040RS
3040RS
3040RS
5
4040RS
12
29'-3" [8.90m]
4028RS 3840RS
6068
6060RS
6068
5
5
11'-23 8" [3.41m]
SECOND FLOOR LVL. 45.71
11'-23 8" [3.41m]
SECOND FLOOR LVL. 45.71
29'-3" [8.90m]
3068
6030RS
4030RS
4040RS
6060RS
5068
6040RS 3068
P.EL. 40.75 E.EL. 40.75
AVE. GRADE. LVL. 40.09
5030LS
BSMT. FL. LVL. 38.54
LEFT ELEVATION SCALE:1/8"-1' 2
- 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)
6
MEAN ROOF LVL. 49.65
U/S CEILING LVL. 48.45 3040RS
3040RS
SCALE:1/8"-1'
12 DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP
31040RS
4030RS
21068
21068
29'-3" [8.90m]
11'-2 8" [3.41m] 3
4 TYP.CELLAR FLR. ASSEMBLY GYPSUM BOARD FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 5 " T&G PLYWOOD SUBFLOOR 8 RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH 1" 2
5068
21068
5
5
4
3
11'-23 8" [3.41m]
SECOND FLOOR LVL. 45.71
6030RS
3 TYP.CELLAR FLR. ASSEMBLY GYPSUM BOARD FLR. JOINTS @ 16" o.c. AS ER STRUC. ENG. 5 " T&G PLYWOOD SUBFLOOR 8 RADIANT HEATING PIPES ON WIRE MESH 1- 12" LIGHT WEIGHT CONC. TOPPING FLOOR FINISH 1" 2
3068
MAIN FL. LVL. 41.65
10'-2 8" [3.11m]
2
4
3068
3068
6068
6068
8068
5
7
5030LS
5068
7
7 6
AVE. GRADE. LVL. 40.09
DRAIN TILE 2-15M CONTINUOUS
7
10'-23 8" [3.11m]
3
5'-1" [1.55m]
ATTIC
3040RS
3
MAIN FL. LVL. 41.65
BSMT. FL. LVL. 38.54
1
ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM
5068
6068
5
21068
5 29'-3" [8.90m]
REAR ELEVATION
- 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE
- 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL
- FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL
4
2668
- 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL
INTERNAL INSULATED WALL
BASEMENT FLOOR:
ROOF RIDGE LVL. 50.85
2
FOUNDATION WALLS: 7
9' [2.74m]
9' [2.74m]
MAIN AND UPPER FLOOR (1 hr FRR):
EXTERIOR WALLS (2 hr FRR):
ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM
DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP
5
- FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION
ATTIC
5068
AVE. GRADE. LVL. 40.09
INTERIOR PARTITIONS ( 1 hr FRR): - 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY
- STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN. - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE
EAVES:
E.EL.: 39.93
3'-1118" [1.20m] 3'-1118" [1.20m]
1 8
U/S CEILING LVL. 48.45
4
1
1 8
MEAN ROOF LVL. 49.65
3
- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT
3'-11 " [1.20m] 3'-11 " [1.20m]
ROOF RIDGE LVL. 50.85
ROOF: - ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
P.EL. 40.70 E.EL. 41.87
P.EL. 40.75 E.EL. 40.75
BSMT. FL. LVL. 38.54
SECTIONAL DETAILS AND SPECIFICATIONS: 1
SECOND FLOOR LVL. 45.71
E.EL.: 41.83 10'-23 8" [3.11m]
5030LS
E.EL.: 41.83
5'-1" [1.55m]
P.EL. 38.83 E.EL. 38.83 10'-23 8" [3.11m]
AVE. GRADE. LVL. 40.09
3068
MAIN FL. LVL. 41.65
5'-1" [1.55m]
MAIN FL. LVL. 41.65
5'-1" [1.55m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
AVE. GRADE. LVL. 40.09
10'-23 8" [3.11m]
MAIN FL. LVL. 41.65
70.5
21068
2668
21068
6
BSMT. FL. LVL. 38.54
DRAIN TILE 2-15M CONTINUOUS
SECTION A-A
SECTION B-B
SCALE:1/8"-1'
SCALE:1/8"-1'
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
SATVINDER MAHENDRU PROJECT:
CIVIC ADDRESS: 13049 COULTHARD ROAD SURREY, BC LEGAL DESCRIPTION: LOT #1 DISTRICT LOT 51 AND 709 GROUP 2 NEW WESTINSTER DISTRICT PLAN 68938
ELEVATIONS AND SECTIONS
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1279
DATE:
AUG. 2017
FILE NO.
SCALE:
1/8" = 1'-0"
V01
SHEET NO:
A 4/6
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
∙
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
SATVINDER MAHENDRU PROJECT:
CIVIC ADDRESS: 13049 COULTHARD ROAD SURREY, BC LEGAL DESCRIPTION: LOT #1 DISTRICT LOT 51 AND 709 GROUP 2 NEW WESTINSTER DISTRICT PLAN 68938
ENERGY DETAIL
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1279
DATE:
AUG. 2017
FILE NO.
SCALE:
N.T.S.
V01
SHEET NO:
A 5/6
GRID
GRID
HEADER
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.) 1/2"CONTROL JOINT FLOOR FINISH ON C/W CAULK AND ROD CONCRETE TOPPING
MIN. 3/8" GAP BETWEEN WINDOW & 1X2 STRAPPING
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
4" ADHERED FLASHING MEMBRANE
INTERIOR
100 mm (4")
FLOOR FINISH ON CONCRETE TOPPING
SHEATHING PAPER BEHIND FLASHING AND INTO WINDOW OPENING INSECT SCREEN
MIN. 2% SLOPE TO DRAIN SEALANT JOINT AT VENT DUCT TO HOUSEWRAP (A.B.)
2"CONTINUOUS FLANGE AT PERIMETER OF HOOD
STUD @ 16" O.C
2"
2
SEALANT OR GASKET (A.B.) BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED
1 MIN 2"
BLDG. PAPER
4.06
23.03
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
3.99
22.61
0.68
4.11
23.29
ADHERED MEMBRANE FLASHING TO LAP 100mm (4") OVER SHEATHING PAPER BELOW
ROOF ASSEMBLY COMPONENTS (W/ ASPHALT SHINGLES) 1 ROOFING SHINGLES 2 POLYTHENE V.B 5 ″ (15.88 MM) OSB SHEATHING 3 8 4 2 x 10 JOISTS W/ R50 BATT @ 24″ O.C. 5 POLYETHYLENE 6 1/2″ (12.7 MM) GYPSUM BOARD 7 INTERIOR AIR FILM
RSI 0.077 0.00 0.136 8.8 0.00 0.08 0.12
R 0.44 0.00 0.77 50.0 0.00 0.45 0.68
SEALANT OR GASKET JOINT AT POLYETHYLENE (A.B. & V.B.) TO PLATE (A.B.)
2X10 FLOOR JOISTS
SEAL POLYETHYLENE (V.B.) TO SHEATHING PAPER (A.B.)
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
9.21
50.34
FLOOR ASSEMBLY OVER UNHEATED SPACE 1 EXTERIOR AIR FILM 2 FLOOR FINISHES (3 4" HARDWOOD) 3 POLYETHYLENE 4 512" CONC. SLAB 5 R-28 INSULATION 9 NATURAL GRADE
RSI 0.03 0.12 0.00 0.15 4.99 0.00
R 0.17 0.68 0.00 0.83 28.00 0.00
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
5.29
29.68
TRIPLE GLAZED WINDOWS & DOORS LOW E, DOUBLE GLAZED (6mm GAP), TEMPERED GLASS εn = 0.1, AIR FILLED WITH VINYL OR FIBRE GLASS FRAME
USI
U
1.4
0.246
SEPERATION AIR SPACE
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
1 MIN.
RSI R 0.03 0.17 0.035 0.20 1.06 6.00 0.00 0.00 0.11 0.62 2.55 14.49 0.00 0.00 0.08 0.45 0.00 0.00 0.12 0.68 .12
1" 2
2a
2 SEALANT OR GASKET (A.B.)
EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
EFFECTIVE RSI / R VALUE OF ENTIRE ASSEMBLY
12mm (1/2")
SEAL POLYETHYLENE (A.B. & V.B.) TO HOUSEWRAP (A.B.)
1X2 STRAPPING
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
PREFINISHED METAL FLASHING C/W END DAMS TO EXTEND 1" PAST END OF WINDOW FRAME
VENTED ALUMINUM SOFFIT PANELS EFFECTIVE RSI - 4.06 SEAL SHEATHING PAPER (A.B.) TO WINDOW FRAME REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
1.5" SILL PLATE
BUILDING - INTERIOR DESIGNERS
EXTERIOR STUCCO CLADDING
- HEAVY- DUTY POLYVINYL CHLORIDE (PVC )
INTERIOR
AIR SPACE W/ 1x2 TREATED WOOD STRAPPING SCREWED THROUGH INSULATION
THERMOPLASTIC WATER PROOFING MEMBRANES ARE OVERLAPPED AND HEAT FUSED ( APPLICATION CODE :CGSB -37-GP-55M)
SEALANT OR GASKET POLYETHYLENE TO PLATE (A.B.)
FLASHING & COUNTER FLASHING
SEALANT OR GASKET (A.B.)
ASPHALT IMPREGNATED PAPER
INSECT SCREEN - NO DAMPERS
EFFECTIVE RSI VALUE = 6.06 ROOFING SHINGLES (M.B.) WATERPROOF ROOF MEMBRANE (M.B.) FOR EAVE PROTECTION 5/8" OSB ROOF SHEATHING W/ H CLIPS WOOD ROOF FRAMING R-50 BATT INSULATION POLYETHYLENE (A.B. & V.B.) GYPSUM BOARD
GRID
1/2″ (12.7 MM) PLYWOOD SHEATHING
2 X 2 BLOCKING AT BOTH ENDS OF VENT 11/2" CONT. VENT
POLYETHYLENE VAPOR BARRIER
ADHERE SUBFLOOR TO HEADER (A.B.) FLOOR FINISH ON CONCRETE TOPPING
EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING
EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 (RSI-1.06)
1/2″ (12.7 MM) GYPSUM BOARD
MIN. 2% SLOPE TO DRAIN
2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. SLOPED SUB-SILL FRAMING
SEALANT OR GASKET (A.B.) REFER TO W-1 FOR EXTERNAL WALL ASSEMBLY DETAIL
INSULATION GUARD
POLYETHYLENE (V.B. AND A.B.) SEALANT OR GASKET (A.B.)
EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
GASKET (A.B.)
BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED
LAP POLYETHYLENE AND SEAL TO ADHERED MEMBRANE (A.B. AND V.B.)
W-1
SEALANT AND BACKER ROD JOINT AT WINDOW FRAME TO MEMBRANE (A.B. AND M.B.) SEALANT FILLET JOINT PREFINISHED METAL DRIP FLASHING
SEALANT BETWEEN POLYETHYLENE AND HOUSEWRAP (A.B.) FLOOR FINISH ON CONCRETE TOPPING
INTERMITTENT 1/8" P.T. SHIM BEHIND WINDOW FLANGE TO CREATE DRAINAGE PATH (ALTERNATELY DRILL HOLES OR SLOTS THROUGH WINDOW FLANGES TO TO ALLOW FOR DRAINAGE)
HOUSEWRAP AT HEADER (A.B.)
BATT INSULATION POLYETHYLEN (V.B.) STAPLED IN PLACED GYPSUM BOARD
BATT INSULATION POLYETHYLENE (V.B.) STAPLED IN PLACE
25mm (1")
ADHERED MEMBRANE FLASHING (M.B.) SILL GASKET (A.B.)
2" MIN.
FILTER CLOTH
CEMENT OR ACRYLIC STUCCO PARGING
SEE 'FLASHING-BEST PRACTICE GUIDE' FOR ADDITIONAL ROOF FLASHING DETAILS
DAMP PROOFING / VAP. BARRIER EFFECTIVE RSI - 4.06 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
8" CONC. FOUNDATION WALL
FINISHED GRADE
4" EXTRUDED POLYSTYRENE R-5/in. 1" 2
REFER TO W-2/A-501 FOR FND WALL ASSEMBLY DETAIL
DRYWALL FINISH
912"
INSECT SCREEN
VENTED ALUMINUM SOFFIT PANELS
FLOOR OVER UNHEATED SPACE EFFECTIVE RSI 2.06
512"
CEMENT OR ACRYLIC STUCCO PARGING
8" MINIMUM
SHEATHING PAPER TO LAP OVER ADHERED MEMBRANE FLASHING
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
SEAL HOUSEWRAP (A.B.) TO FRAMING
CONTINUE EAVE PROTECTION 12" BEYOND INSIDE FACE OF WALL
ADHERED MEMBRANE FLASHING TO EXTEND 4" AND LAP OVER SHEATHING PAPER
INTERIOR
1/2"
UDC DESIGN CENTER LTD
ROD AND SEALANT
4" FLANGE
25.4mm (1")
R 0.17 0.62 6.00 0.00 0.62 14.49 0.00 0.45 0.00 0.68
WALL ASSEMBLY COMPONENTS (W/ STUCCO CLADDING) 1 EXTERIOR AIR FILM 3 " STUCCO FIN. 2 4 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER2 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM
SHEATHING PAPER TO LAP METAL FLASHING
ROD AND SEALANT 1
RSI 0.03 0.11 1.06 0.00 0.11 2.55 0.00 0.08 0.00 0.12
VALUES ADOPTED FROM CANADIAN WOOD COUNCIL
4" FLANGE 6
WALL ASSEMBLY COMPONENTS (W/ NINYL CLADDING) 1 EXTERIOR AIR FILM 2 VINYL SIDING (NO AIR SPACE) 3 EXTERNAL 1.5" RIGID MINERAL FIBRE INSUL. R-6 4 ASPHALT IMPREGNATED PAPER 5 1/2″ (12.7 MM) PLYWOOD SHEATHING 6 2×6 FRAMING FILLED WITH R22 BATT @ 16″ O.C. 7 POLYETHYLENE 8 1/2″ (12.7 MM) GYPSUM BOARD 9 FINISH: 1 COAT LATEX PRIMER AND LATEX PAINT 10 INTERIOR AIR FILM
EXTERIOR
4"
EFFECTIVE RSI - 3.99 REFER TO W-1/ A-501 FOR EXTERNAL WALL ASSEMBLY DETAIL EXTERNAL WALL W/1.5" RIGID MINERAL FIBRE INSUL. R-6
RSI / R VALUE CALCULATIONS FOR ASSEMBLIES
EFFECTIVE USI VALUE - 1.4 OPERABLE VINYL OR FIBERGLASS FRAME LOW ENERGY, DBL. GLAZED TEMP. GLASS W/ SLOPED SILL WEATHER STRIPPING
GRID
COMPLETE W/ 4" EXTRUDED POLYSTYRENE FOAM BOARD INSUL. R-5/in.
WOOD FRAMING (STUDS OR STRAPPING)
W-2 UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
SATVINDER MAHENDRU PROJECT:
CIVIC ADDRESS: 13049 COULTHARD ROAD SURREY, BC LEGAL DESCRIPTION: LOT #1 DISTRICT LOT 51 AND 709 GROUP 2 NEW WESTINSTER DISTRICT PLAN 68938
GENERAL DETAIL
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1279
DATE:
AUG. 2017
FILE NO.
SCALE:
N.T.S.
V01
A 6/6 SHEET NO: