302'-43 8" [92.16m] REAR SETBACK 84' [25.60m]
120' [36.58m] 84' [25.60m]
BASKETBALL COURT 4200 SQFT
50' [15.24m]
7'-218" [2.19m] 23'-018" [7.02m]
8'-47 8" [2.56m]
BUILDING - INTERIOR DESIGNERS
9'-63 4" [2.91m]
90' [27.43m]
26'-4" [8.03m]
20'-4" [6.20m]
14'-8" [4.47m]
8'-10" [2.69m]
E.EL.:81.34 P.EL.:91.37
DN
DECK
FIRE PIT PATIO
70'-10" [21.59m] BUILDING DEPTH
E.EL.:81.12 P.EL.:91.37
13409 56 AVE SURREY, BC ROOF RIDGE LVL.: 92.46 MEAN ROOF LVL.: 89.93 U/S CEILING LVL.: 87.40 SECOND FLOOR LVL.: 84.65 MAIN FLOOR LVL.: 81.54 AVG BLDG GRADE: 80.94
E.EL.:80.60 P.EL.:91.37
E.EL.:80.70 P.EL.:91.37 PORCH
30' [9.14m] FRONT SETBACK
UDC DESIGN CENTER LTD
SOCCER FIELD 10800 SQFT
122'-318" [37.26m] LEFT SETBACK
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MARGARET ERCEG
35' [10.67m] BUILDING WIDTH
SITE PLAN
8' [2.44m] RIGHT SETBACK
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1302
DATE:
SEP. 2017
FILE NO.
SCALE:
1/16"=1'-0"
V12
PROJECT: CIVIC ADDRESS: 13409 56 AVE, SURREY, BC LEGAL DESCRIPTION: LOT 52 SECTION 8 TOWNSHIP 2
SHEET NO:
A
1/6
35'-0" 20'-4"
14'-8"
10'-6" 9'-6"
10'-5"
DN 2668
8040RS
15'-1"
11'-1"
3030RS
section-1
8'-2"
64'-3"
21040RS
2668
2'-0"
4'-1"
3068
7'-6"
8'-0"
3'-5"
3068
3068
BUILDING - INTERIOR DESIGNERS
S CO
2'-0"
10'-2"
21068
21040RS
SMOKE ALARM & CARBON MONOXIDE (CO) ALARM
4'-6"
2668
UP
7'-6"
4'-0"
8'-6"
2030RS
6040RS
36'-0"
12'-8"
7'-10"
3468
2668
2668
1'-0"
2'-5"
2668
5068 8040TC
6050TS
6'-7"
UDC DESIGN CENTER LTD
28'-0"
3040RS
16080
20'-9"
10'-4"
3068
E5
DN 1'-0"3'-7"
7'-10"
8'-4" 18'-9"
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
5'-4"
E5
5'-7"
5'-4" 10'-8"
35'-0"
SHEET TITLE:
MARGARET ERCEG PROJECT: CIVIC ADDRESS: 13409 56 AVE, SURREY, BC LEGAL DESCRIPTION: LOT 52 SECTION 8 TOWNSHIP 2
MAIN FLOOR PLAN
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1302
DATE:
SEP. 2017
FILE NO.
SCALE:
V12
SHEET NO:
A
2/6
E5
35'-0" 20'-4" 14'-8"
14'-6"
6'-5"
50'-8" 2'-0"
21040RS S
15'-0"
10'-6"
2'-6"
21040RS section-1
6430RS
2668
21068
3'-11"
2'-4"
2668
3030RS
2'-4"
3068
2'-4"
3'-11"
8'-1"
5068
3050RS
8040RS
3'-0"
5'-4" 12'-6"
50'-8"
7'-4"
3050RS
8'-6"
S
2668
BUILDING - INTERIOR DESIGNERS
7'-4"
5'-8"
2668
2'-10"
14'-8"
3'-5"
0"
5'-8"
2668
8'-8"
2668
DN
4'-0"
2668
21'-2"
21068
12'-6"
S
8'-6"
12'-6"
6430RS
7'-1" 1'-0"
4'-6"
1'-0"
UDC DESIGN CENTER LTD
14'-8"
7'-1"
10'-9"
14'-1"
5'-8" 16'-5"
35'-0"
E5
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MARGARET ERCEG PROJECT: CIVIC ADDRESS: 13409 56 AVE, SURREY, BC LEGAL DESCRIPTION: LOT 52 SECTION 8 TOWNSHIP 2
TOP FLOOR PLAN
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1302
DATE:
SEP. 2017
FILE NO.
SCALE:
V12
SHEET NO:
A
3/6
8'-33 8" [2.52m]
ROOF RIDGE LVL. 92.46
MEAN ROOF LVL. 89.93
12
8'-312" [2.53m]
12
LIST OF MATERIALS
1
9
U/S CEILING LVL. 87.40
5
6430RS
29'-6" [8.98m]
9'-014" [2.75m]
3
5 9
10'-214" [3.11m]
SECOND FLOOR LVL. 84.65
MAIN FL. LVL. 81.54
1.
ASPHALT SHINGLE 40 YRS - IKO CAMBRIDGE, DUAL BLACK
2.
BUILT-IN GUTTER - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT
3.
1 x 8 ON 2" X 10" FASCIA BOARD
4.
1" X 4" WOODEN TRIM
5.
HARDY PANEL
6.
ALUMINUM FRAMED WINDOW AND PATIO DOOR
7.
WOODEN EXTERIOR DOOR
8.
STONE
9.
CEDAR SHAKE SHINGLES
4 6050TS
5080
8050TC
7
6
5
E.EL.:80.60 P.EL.:80.91
8
E.EL.:80.70 P.EL.:80.91
8
AVE. GRADE. LVL. 80.94
8'-33 8" [2.52m]
ROOF RIDGE LVL. 92.46
front elevation scale: 14" = 1'-0"
12 12
8'-312" [2.53m]
MEAN ROOF LVL. 89.93
U/S CEILING LVL. 87.40
SECOND FLOOR LVL. 84.65
21040RS
29'-6" [8.98m]
TOTAL AREA: 1020.48 SQ. FT. ( 94.80 SQ.M.) DISTANCE TO PROPERTY LINE: 8'-0" (2.44 M) ≈ 4.0M MAX. ALLOWABLE UNPROTECTED AREA @ 18% = 183.68 SQ. FT. PROPOSED UNPROTECTED AREA: 63.32 SQ. FT (20.28 SQ. M.)
9'-014" [2.75m]
RIGHT ELEVATION
21040RS
11.33
11.33 5068
5
right elevation scale: 14" = 1'-0"
10'-214" [3.11m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
2
MAIN FL. LVL. 81.54
2030RS 6
21040RS 11.33
5
21040RS 11.33
3040RS
E.EL.:80.70 P.EL.:80.91
12 3068
E.EL.:81.12 P.EL.:80.91
AVE. GRADE. LVL. 80.94
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MARGARET ERCEG PROJECT: CIVIC ADDRESS: 13409 56 AVE, SURREY, BC LEGAL DESCRIPTION: LOT 52 SECTION 8 TOWNSHIP 2
FRONT AND RIGHT ELEVATION
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1302
DATE:
SEP. 2017
FILE NO.
SCALE:
1/4"=1'-0"
V12
SHEET NO:
A
4/6
8'-33 8" [2.52m]
ROOF RIDGE LVL. 92.46
12 12
8'-312" [2.53m]
MEAN ROOF LVL. 89.93
29'-6" [8.98m]
5
8040RS
3068
E.EL.:81.12 P.EL.:80.91
AVE. GRADE. LVL. 80.94
E.EL.:81.34 P.EL.:80.91 ROOF RIDGE LVL. 92.46 8'-33 8" [2.52m]
9'-014" [2.75m] MAIN FL. LVL. 81.54
5
8040RS
10'-214" [3.11m]
SECOND FLOOR LVL. 84.65
rear elevation
12 12
8'-312" [2.53m]
MEAN ROOF LVL. 89.93
LEFT ELEVATION
TOTAL AREA: .1211 SQ. FT. SECOND FLOOR LVL. DISTANCE TO PROPERTY LINE: 25'-0" (7.62 M) ≈ 8.0M 84.65 MAX. ALLOWABLE UNPROTECTED AREA @ 100% = 1211 SQ. FT. ( 69 SQ.M.) PROPOSED UNPROTECTED AREA: 84 SQ. FT (7.01 SQ. M.)
29'-6" [8.98m]
9'-014" [2.75m]
U/S CEILING LVL. 87.40
left elevation UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
MAIN FL. LVL. 81.54
3050RS
3050RS
15
15
6430RS
3030RS 9
19
5
10'-214" [3.11m]
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
U/S CEILING LVL. 87.40
3030RS 9
5
E.EL.:81.34 P.EL.:80.91
6040RS 16
16080
E.EL.:80.60 P.EL.:80.91
AVE. GRADE. LVL. 80.94
CLIENT:
SHEET TITLE:
MARGARET ERCEG PROJECT: CIVIC ADDRESS: 13409 56 AVE, SURREY, BC LEGAL DESCRIPTION: LOT 52 SECTION 8 TOWNSHIP 2
REAR AND LEFT ELEVATION
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1302
DATE:
SEP. 2017
FILE NO.
SCALE:
V12
SHEET NO:
A
5/6
ROOF RIDGE LVL. 92.46 8'-33 8" [2.52m]
DUROID ROOF BUILDING PAPER ON 12" PLYWOOD ENG.TRUSSES @24" O/C R-40 BATT INSULATION 6 MIL POLY V.B. (LAPPED JOINTS,SEAL ELECT. OUTLETS) (WARM SIDE) 5 8" GYPSUM BOARD BUFFLES 2" CLEAR FROM TOP
MEAN ROOF LVL. 89.93 8'-312" [2.53m]
12 12
ATTIC ATTIC VENTILATION AS PER BUILDINGCODE A/300 OF INSULATED CEILING AREA MIN. 25% OF VENTING @TOP & 25% @ BOTTOM
U/S CEILING LVL. 87.40
29'-6" [8.98m]
21040RS
5068
12 12
112" CONC. TOPPING
5
4
3'-0" HIGH HAND RAIL
9'-014" [2.75m]
21040RS
10'-214" [3.11m]
SECOND FLOOR LVL. 84.65
4
21068
2668 3468
3040RS
112" CONC. TOPPING
3068
5
8" ANCHOR BOLTS @ 36" O.C.(TYOP)
MAIN FL. LVL. 81.54
SECTION
2-15M CONTINUOUS
AVE. GRADE. LVL. 80.94
1/4" = 1'-0" F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(121")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(85") TYPE X GYPSUM BOARD
SUPPORTED WALL (10M BAR) NET BACKFILL HT.
A
B
LESS THAN 7'-6"
0"
0"
7'-6" TO 8'-0"
18"
20"
8'-1" TO 9'-0"
14"
20"
9'-1" TO 10'-0"
12"
20"
NOTE: 1. REBAR TO BE 230 MPa MINIMUM. 2. CONCRETE TO BE 20 MPa MINIMUM. 3. BACKFILL NOT TO EXCEED 20 KN/ cubic METER
5 8" ANCHOR BOLT @ 48" o.c. (MAX. OF 1 PLATE UNDER JOIST.)
TYPICAL FLOOR CONSTRUCTION
2" FROM GARAGE SLAB OR SIDEWALK 8" MIN. FROM FINISH GRADE GARAGE SLAB OR FINISHED GRADE
W1(C): -38mm(121")X 89mm(312") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD
W1(C): -38mm(112")X 89mm(321") STUDS SPACED 400mm OR 600mm -WITH 89mm THICK ABSORPTIVE MATERIAL -15.9mm(5 8") TYPE X GYPSUM BOARD
5
8" TYPE "X" GYPSUM BOARD ON BOTH SIDES CONTINUOUS TO UNDERSIDE OF FLOOR SHEATHING (HATCHED AREA)
HORIZONTAL STEEL = 'B' (LAP JOINTS 18" MINIMUM) APPLY DAMPROOFING AS REQ. BY N.B.C. SECT.9-13
NET BACKFILL HEIGHT
MAX. COVER 2"
1
F.R.R WALL DETAIL
8"
TYPE "X" GYPSUM BOARD AGAINST SEPARATION WALL
3 F5(D): -SUBFLOOR OF 15.5mm PLYWOOD, OSB OR WAFERBOARD OR 17mm TONGUEAND GROOVE LUMBER -38mm(112")X 235mm(914") WOODFLOOR JOISTS -ABSORPTIVE MATERIAL IN CAVITY -METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm(58") TYPE X GYPSUM BOARD
-METAL FURRING CHANNELS SPACED 600mm O.C. -15.9mm (58") TYPE X GYPSUM BOARD
15M @ 15" o.c.
DETAIL AT 'A'
ON PLAN
8"
5
EAVES:
- 5 8" TYPE "X" GYPSUM BOARD (FIN. AS PER OWNER)
6
EXTERIOR WALLS (2 hr FRR): - STUCCO ON WIREMESH - METAL LATH - 19MM (3/4") AIR SPACE / @ 16" O.C. - 15# BREATHER TYPE BUILDING PAPER - 15 32" SHEATHING - 2 x 6 STUDS @ 16" O.C. - R-20 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
F.R.R. CEILING DETAIL
2-15M CONT. AS NOTED ON PLAN
BASEMENT FLOOR: - FINISH FLOOR: TO OWNERS SPEC'S - 0'-6" CONC. SLAB - 10 GA 6 x 6 WIRE MESH - 6 MIL. POLY. V.B. - R-10 RIGID INSULATION - MIN. 12" COMPACTED GRANULAR FILL
INTERIOR PARTITIONS ( 1 hr FRR): - 1/2" GYPSUM BOARD (BOTH SIDES) - 2 x 4 STUDS @ 16" O.C. - INSUALTED CAVITY
4
MAIN FLOOR (1 hr FRR): - FINISH FLOOR: TO OWNERS SPEC'S - P.T. 2x10 @16 o.c. JOISTS AS PER MANUFACTURERS SPECS - 11/2"th. CONCRETE TOPPING - R-40 SPRAT FOAM INSULATION
- BUILT-IN GUTTER - 2 x 12 FASCIA BOARD - METAL SOFFIT WITH 2" CONTINUOUS SCREENED VENT
NOTCH OUT 12" TYPE "X" GYPSUM BOARD FOR FLOOR JOISTS
5
ROOF: - ROOF FINISH: 210 # ASPHALT SHINGLES ROOF - STARTER STRIP - 716" OSB SHEATHING c/w. H. CLIPS - PREFAB. ENG. TRUSSES @ 24" O.C. - R-50 BATT INSULATION - 6 MIL. POLY. V.B. - 5/8" DRYWALL FIN.
SUBFLOOR
4" CONC. SLAB ON 6 MIL. POLY. V.B. ON 6" COMPACTED GRANULAR FILL
4"Ø PERIMETER DRAIN TILE WITH DRAIN ROCKS
SECTIONAL DETAILS AND SPECIFICATIONS:
2
VERTICAL STEEL = 'A' (ALTERNATE HOOKS)
24"
FLOOR JOIST
30 MIN. F.R.R. ASSEMBLY DETAIL
212" RIGID INSULATION (N.I.C.) TO BELOW FROSTLINE OR 2x4 FURRED WALL w/ R12 F.G. BATT INSUL. (N.I.C.) WHERE INDICATED
8" REINFORCED CONCRETE FOUNDATION WALL
A
EXTERIOR WALL CONSTRUCTION
AS NOTED
BUILDING - INTERIOR DESIGNERS
UDC DESIGN CENTER LTD
3
7
FOUNDATION WALLS: - 2 x 6 SILL PLATE - 8" CONC. FOUNDATION WALL - 2 COATS OF ASHPALT EMULSION TO EXTERIOR FACE - 2 - 15M T & B, 10M @16" O.C E/W.1.F UP TO GRADE
INTERNAL INSULATED WALL - 2" AIR SPACE - 2 x 4 SPF # 2 STUDS @ 24" O.C. (U.N.O.) - R-14 BATT. INSULATION - 6 MIL. POLY. V.B. - C/W TUCK TAPE JOINTS - 1/2" DRYWALL
SUPPORTED WALL SECTION UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
CLIENT:
SHEET TITLE:
MARGARET ERCEG PROJECT: CIVIC ADDRESS: 13409 56 AVE, SURREY, BC LEGAL DESCRIPTION: LOT 52 SECTION 8 TOWNSHIP 2
SECTION AND DETAIL
DRAWN BY:
G.S.B.
PROJECT NO.
CHECKED BY:
B.M.
1302
DATE:
SEP. 2017
FILE NO.
SCALE:
1/4"=1'-0"
V12
SHEET NO:
A
6/6