PROPERTY DESCRIPTION :
Proposed Tenant Improvement for
CIVIC ADDRESS: UNIT 117, 8166 - 128 STREET, SURREY, B.C.
UNIT 117, 8166 - 128 STREET, SURREY, BC.
BUILDING CODE SYNOPSIS : BC BUILDING CODE 2012 1. BUILDING CRITERIA : TOTAL BUILDING AREA : 46601 ft2 (4330.95 m2) BUILDING HEIGHT : 2 STORIES BUILDING FACES : 3 STREETS BUILDING IS SPRINKLERED. OCCUPANCY (BLDG.) : F2, E, D & A2
24'-0"
ED
W2
ED
18098FX
W2
ED
2. EXISTING CONSTRUCTION : GROUND FLOOR : NON-COMBUSTIBLE 2ND FLOOR : NON-COMBUSTIBLE ROOF : NON-COMBUSTIBLE EXT. WALLS : NON-COMBUSTIBLE
W4 3. BUILDING TO COMPLY WITH FOLLOWING ARTICLES: A2 : 3.2.2.24 E : 3.2.2.57 D : 3.2.2.54 F2 : 3.2.2.70
Interior Partition Wall L:8' W:2" D:1'6"
UNIT # 116 VIVAH COLLECTION (GROUP -E)
Coffee Table
Proposed Wall
Waiting Area
Cutting
Cutting
30" HIGH BASE CABINET
PROPOSED TENANT IMPROVEMENT : BC BUILDING CODE 2006
FLOOR AREA 1248 SQFT
4. SCOPE : 4.a. 4.b.
UNIT # 118 TRADITIONAL BRIDAL SHOP (GROUP -E)
Shampoo
Sink H/C
6. TOTAL EXISTING FLOOR AREA : 1243ft2 (115.53m2) APPROX.
TRAVEL DISTANCE 65' < 25 M
Reception
2
B7012
B2812
Product Display
7. OCCUPANT LOAD (BCBC 2006 3.1.17): 10 PERSONS ( Max. )
Shampoo
8. OCCUPANCY FIRE SEPARATIONS (BCBC 2006 TABLE 3.1.3.1.): EXISTING SEPARATION BET. SUBJECT UNIT NO.117 & ADJACENT UNITS NO.116 EAST SIDE IS 1 HR. F.R.R.; EXISTING SEPARATION BET. SUBJECT UNIT & UNIT NO.118 WEST SIDE IS 1 HR. F.R.R. TO REMAIN.EXISTING SEPARATION BET. SUBJECT UNIT & UNIT NO.128 SOUTH SIDE IS 1 HR. F.R.R. TO REMAIN.EXISTING SEPARATION BET. SUBJECT UNIT & UNIT ABOVE IS 2 HR. F.R.R.
Sink H/C
W3
Pedicure
9. WASHROOM / WATER CLOSET (BCBC 2006 3.7.2.4) ONE EXISTING WASHROOM WITHIN SUBJECT UNIT IS H/C
52'-0"
H/C
2
10. EXITS (BCBC 2006 3.4.2.1 TABLE 3.4.2.1.B): FLOOR AREA < 200 m2, 1 EXIT REQUIRED & PROVIDED 11. LOCATION OF EXIT /TRAVEL DISTANCE (BCBC 2006 3.4.2.1.b): TRAVEL DISTANCE IS LESS THAN 82.02 ft. (25m.)
Product Display
KEYPLAN(Bldg.B)
3068
LCU3690R
30" HIGH BASE CABINET U781890
12. PARKING : COMMON PARKING IN PLAZA
STORAGE U741890
93 SQFT
EXISTING 2HR. FRR NON-COMBUSTIBLE FLOOR ASSEMBLY
Massage Bed 30" HIGH BASE CABINET 30" HIGH BASE CABINET
Curtain Drape Barrier
Clearance from Panel
Electrical Panel
W1
W27362
506 SQFT Massage Bed
H/C
CONCRETE TOPPING METAL DECKING STEEL JOIST
WALL ASSEMBLIES : W1
T-BAR CEILING 12'-0" HIGH BRING SPRINKLER HEAD DOWN FLUSH WITH U/S CEILING
W2
F2 EXISTING SECOND FLOOR LEVEL
D1 EXISTING H/C WASHROOM
Cabinetry
W1
W3
Multi-functional Sink Mini-Fridge
W4
30" HIGH BASE CABINET
W3
15'-0"
W3
ELEV.
UNIT # 128 VIVAH'S BRIDAL SHOP (GROUP -D)
F1
11'-0"
OCCUPANCY FOR 10 PERSONS
( APPROX. )
30" HIGH BASE CABINET
W3
EXISTING NON-RATED INTERIOR WALL 1/2" THK. GWB BOTH SIDE 2" X4" WOOD/STEEL STUDS @16"O.C.
SCHEDULES : Door :
EXISTING EXTERIOR WALL CONCRETE TILT - UP PANELS Note : PROVIDE R14 INSULATION / VAPOUR BARRIER ALONG EXTERIOR WALL
Frame :
3'-0" x 6'-8" WOOD HOLLOW CORE WOOD
Hardware : 1 1/2 PR. BUTT CLOSER LOCKSET LEVER HANDLE
EXISTING 1 HOUR F.R.R. DEMISING WALL TO REMAIN EXISTING DOOR
H/C
W3620
DOOR & WINDOW
EXISTING CEILING LEVEL
Microwave
7'-0 1/8"
BUILDING - INTERIOR DESIGNERS
PORTABLE CHAIR (WHEELCHAIR ACCESSIBLE)
W3
LAYOUT OF THE UNIT EXIT & EMERGENCY SIGNS
5. INTENDED USES : CLOTH SHOP GROUP E OCCUPANCY
30" HIGH BASE CABINET
UDC DESIGN CENTER LTD
Product Display
Make-Up
F1
F2
EXISTING NON-RATED 7'-0" HIGH INTERIOR WALL 1/2" THK. GWB BOTH SIDE 2" X 4" WOOD STUDS @16"O.C.
EXISTING WINDOW
ELECT'L. LEGEND : EMGY EXIT
EMERGENCY LIGHT
EXIT SIGN
FLOOR ASSEMBLIES: EXISTING CONCRETE FLOOR CONCRETE SLAB ON GRADE EXISTING 2 HOUR F.R.R. FLOOR
EXISTING FIRST FLOOR LEVEL
SLAB ON GRADE
1
Floor Layout Plan 1/4"=1'
UNIT # 202, 7750 128 STREET SURREY BC, V3W0R6 TEL: 778-858-8794 FAX:604-593-5864 EMAIL: UDCDESIGN @HOTMAIL.COM WEB: WWW.UDCDESIGNS.COM
2
PROJECT:
Section 1/4"=1'
Proposed Tenant Improvement for GLAMOUR WORLD AYURVEDIC INC (BEAUTY SALON)
ADDRESS: CIVIC ADDRESS: LEGAL DESCRIPTION:
UNIT # 117, 8166-128 STREET SURREY BC V3W 1R1 LOT 235,236 SECTION 29 TOWNSHIP 2 PLAN BCS1022 NWD
SHEET TITLE:
#117 unit floor plan
DRAWN BY:
G.S.B
PROJECT NO.
CHECKED BY:
B.M.
1259
DATE:
JAN. 2017
FILE NO.1259
SCALE:
1/4"=1'-0"
V101
SHEET NO:
A1