collection
• COD • conductivity • dissolved oxygen • ORP • pH • pocket checkers • photometry
WATER
2012/13 Instrumentation
Contents
From drinking water to waste water, aquaculture to swimming pools, rivers to sea water … Hanna meters are used where precision, measurement and analysis make the difference 2
Introducing the Hanna Water Collection 2012/13
4
Who we are
6
Our business
8
Our brand
10
How we work
12
Our products • • • • • • •
chemical oxygen demand conductivity dissolved oxygen ORP / Redox pH photometry temperature
• turbidity
58
Service and calibration
60
Warranty
61
Index
Introducing the
Hanna Water
Collection
2012/13
Welcome to the Hanna Water Collection, our first catalogue dedicated to water quality measurement and analysis throughout the Norden market. In the two years since we launched HannaNorden, we are proud to have built a strong team dedicated to supporting the Hanna range across Denmark, Finland, Iceland, Norway and Sweden. Sales and customer support tailored to the Nordic markets are now supported by local warehousing and service. Our popular online webshop provides customers with the opportunity to purchase in local currency. For 2012/13 we are now delighted to bring you our latest initiative, the Hanna Water Collection, showcasing our top selling lines and popular products used in water applications across Norden. At Hanna we pride ourselves on bringing competitive, innovative products to the marketplace to meet popular demand. This latest collection does just that. Divided into major parameters, it features a comprehensive selection of pocket, portable and bench meters to suit a variety of budgets. A broad choice of electrodes, solutions and accessories supports this colourful mix of intelligent instrumentation dedicated to scientific measurement and analysis.
At Hanna we love our customers, we care for our products and we derive huge pleasure in finding the perfect match – delivering happy, long-lasting
The catalogue itself adopts a fresh and unusual approach to catalogue presentation. Large full colour entries offer an inspired look at what makes Hanna products popular, appealing and easy to use. Descriptions packed with information are designed to answer the questions you want to know. Our goal has been to present a clear incisive guide to our top products. The result is a new and exciting guide packed full of facts, features, specifications and applications to answer, inspire and reassure – the Hanna Water Collection. We love it. We hope you will agree. Please enjoy!
solutions over and over again Mats Bergander Director HannaNorden
2
3
Who we are
Hanna Instruments is a global company and a world leader in the manufacture and supply of scientific instrumentation and test kits
Hanna Instruments is a
global company and a
world leader in the manufacture and supply of scientific instrumentation and test kits. We are recognised for our investment in growth and development and enjoy a long-standing reputation for
product innovation.
Our comprehensive in-house programme of research, development and production supported by over 60 offices worldwide enables us to deliver a strong
brand with an impressive product range.
Reinforced by a commitment to finding competitive, smart solutions, it is an approach that has secured our place on the world
stage as the largest family-owned player in our
market sector.
4
5
Our approach is simple, smart and straightforward
Our business
Our business is about people
Hanna offers a simple no frills no nonsense ethos. We maintain a sharp focus on providing smart solutions to meet customer requirements. Our goal is straightforward; to meet the high pressure demands of a modern marketplace at the same time as continuing to deliver the best
customer service.
6
7
Our brand
Round the world the Hanna brand is renowned for its competitive edge
Round the world the Hanna brand is renowned for its competitive edge Adapting high end technology to meet demand for advanced measurement solutions in low to mid markets, Hanna is synonymous with market revolution. World firsts in pH and pocket testers have established our reputation for invention and innovation. Hanna automatic mini titrators broadened access to specialist chemical testing. The unique calibration check featured across Hanna temperature testing equipment raised industry expectations and set new standards among lower market entry products. Pre-amplified and double-junction electrodes, process pH with integrated cellular communication, pocket photometers, portable refractometers – all are the result of a continuous programme of research and development that lies at the heart of Hanna.
Full circle ethos When you buy a Hanna product, you can be confident it is the result of a fully-integrated research, development and manufacturing process. Unlike many instrumentation companies, Hanna does not subscribe to buying-in a product and simply putting the Hanna name on the meter. We research the technology, design the product and implement each and every stage of production.
Our growth and development owes its success to our full circle ethos.
8
•
Purpose-built production in Romania supported by on-site research and development
•
Dedicated research and development laboratory in USA
•
Full UK Hanna Service Centre
•
UKAS accredited Hanna Temperature Calibration Laboratory in UK
9
How we work
We want to work with you to explore your application understand your requirements and deliver the right solution
From your initial enquiry through to the purchase, installation and after sales service and support of your chosen instrument, we listen and we care.
Product advice, sales and service are always on hand through our external and internal sales teams.
Hanna products are available direct from Hanna or through one of our distributors.
The focus at Hanna is on enjoying what we do. From designing complete waste water analysis systems to photometers for precision sample testing; supporting quality control for drinking water production to measuring dissolved oxygen in fish farms and delivering laboratory grade accuracy even under harsh industrial conditions ‌
The Hanna Service Centre in the UK offers comprehensive repair and servicing for all Hanna meters.
Our Hanna Temperature Calibration Laboratory offers fully accredited UKAS certification for all temperature testing equipment.
Hanna products are found in an amazing range of applications. And we love pushing boundaries, deepening our knowledge and broadening our expertise.
10
11
COD • COD • COD • COD
COD bench meter with bar code reader
The Hanna HI 83214 multiparameter photometer is a compact instrument that allows operators to conduct a complete wastewater analysis using a single meter.
Main benefits
A complete system for wastewater analysis
part no: HI 83214
• Easy COD measurement Pre-calibrated to measure COD levels at three ranges at the touch of a key pad • Outstanding measurement quality An advanced optical system ensures high accuracy measurements across the range • Space saving Neat and compact, the HI 83214 eliminates clutter and saves space in the laboratory
A plus for tight budgets
More about COD Used as a measurement of pollutants, COD is measured on both influent and effluent water in municipal and industrial wastewater treatment plants to give an indication of the efficiency of the treatment process. This is normally expressed as COD removal - measured as a percentage of the organic matter purified during the cycle.
Its multiparameter facility makes this meter particularly suitable for a wide range of applications and a great plus for operators and organisations working to tight budgets.
On or off-site testing
The HI 83214 bench meter can also be used to measure total ammonia, nitrogen and total reactive phosphorus as well as chemical oxygen demand.
COD bench meter with bar code reader
Water
Water
part no: HI 83214
COD • COD • COD • COD
This photometer can be used both in the laboratory and on location for on-site testing. Designed to be as easy to use as possible, it can be operated by technicians at all skill levels.
12
UST NOT J
Supplied with: •
5 cuvettes
•
Batteries
•
12 Vdc adapter
• This powerful all-in-one product is designed and built to perform COD analysis in accordance with EPA 410.4 and ISO 15705:2002 standards. Ensuring accurate and repeatable results, it is the ideal tool for documenting waste treatment processes.
Instructions
NB: reagent is not supplied as standard with the HI 83214 as ranges vary. See over page for options.
To assist efficient data collection, the instrument can be connected to a PC through an RS232 serial port. Stored measurements can be downloaded using Hanna HI 92000 software.
www.hannanorden.com
COD!
: easures m o s l a ia Ammon e Chlorin Nitrate n Nitroge orus Phosph
Parameter
Range
Method
Reagent Code
Ammonia HR
0 to 100 mg/L
Nessler
HI-93764B-25
Ammonia LR
0.00 to 3.00 mg/L
Nessler
HI-93764A-25
Chlorine, free
0.00 to 5.00 mg/L
DPD
HI-93701-01, HI-93701-03
Chlorine, total
0.00 to 5.00 mg/L
DPD
HI-93711-01, HI-93711-03
COD HR
0 to 15000 mg/L
Dichromate
HI-93754C-25
COD LR
0 to 150 mg/L
Dichromate EPA
HI-93754A-25
COD LR
0 to 150 mg/L
Dichromate Hg-free
HI-93754D-25
COD LR
0 to 150 mg/L
Dichromate ISO
HI-93754F-25
COD MR
0 to 1500 mg/L
Dichromate EPA
HI-93754B-25
COD MR
0 to 1500 mg/L
Dichromate Hg-free
HI-93754E-25
COD MR
0 to 1000 mg/L
Dichromate ISO
HI-93754G-25
Nitrate
0.0 to 30.0 mg/L
Chromotropic acid
HI-93766-50
Nitrogen, total
0.0 to 25.0 mg/L
Chromotropic acid
HI-93767A-50
Nitrogen, total HR
10 to 150 mg/L
Chromotropic acid
HI-93767B-50
Phosphorus, acid hydrolyzable
0.00 to 5.00 mg/L
Ascorbic acid
HI-93758B-50
Phosphorus, reactive
0.00 to 5.00 mg/L
Ascorbic acid
HI-93758A-50
Phosphorus, reactive HR
0.00 to 100.0 mg/L
Vanadomolybdophosphoric acid
HI-93763A-50
Phosphorus, total
0.00 to 3.50 mg/L
Ascorbic acid
HI-93758C-50
Phosphorus, total HR
0.00 to 100.0 mg/L
Vanadomolybdophosphoric acid
HI-93763B-50
Product Code
HI 83214
Light Source
3 tungsten lamps with narrow band interference filter 420/525/610 nm
Light Detection
4 silicon Photocells
Power Supply
2 x 9V battery or 12 Vdc adapter
Auto Shut-off
after 10 minutes of non-use
Environment
0 to 50°C ; RH max 95% non-condensing
Dimensions
230 x 165 x 70 mm
Weight
640 g
HI 92000 software Hanna software is designed to run on Windows and allows data collection from any Hanna meter with a datalogging capability. NB: Hanna software is not tested on Apple Mac platforms, nor can it be guaranteed to work with the latest versions of Windows.
info@hannanorden.com
+46 300 404018
www.hannanorden.com
info@hannanorden.com
Selecting the right reagent COD levels vary depending on the application and process measuring points. To help select the correct reagent for your particular requirements, Hanna offers three separate reagent ranges in boxes of 25 vials. For full details, see over page.
+46 300 404018
chemical oxygen demand
chemical oxygen demand
Specifications
COD measurement can also be used to check pollutant levels in other applications including power plants, chemical manufacturing plants, commercial laundries, pulp and paper mills, agriculture and animal waste run-off as well as in environmental studies and general education.
13
COD • COD • COD • COD
Reagents
Three measurement ranges
In response, Hanna offers three separate ranges of reagent from which operators can choose.
Hanna COD reagent formulations are based on those specified in recognised international standard methods. They meet the requirements of conformity testing against national and international standards and have been developed in accordance with Standard Methods 5220D, USEPA 10.4 and ISO 15705:2002.
Quick, efficient measurement No need for reagent preparation or glassware cleaning - with Hanna pre-dosed vials, test preparation time is dramatically reduced.
To order, simply select the range most appropriate to your application:
Safe reagents
Low Range (LR): 0 to 150 mg/L
•
Vials and caps have been designed to avoid accidental reagent spills
•
Pre-dosed reagents minimise the amount of chemical to be used
Hanna Reagents are available in the following formats:
14
Robust and durable, the main body of the instrument is machined from a single block of metal. Temperature within the block is carefully controlled using a sophisticated electronic thermostat and can be verified quickly and easily by placing a thermometer in the temperature well provided. The reactor is equipped with 6 pre-defined and 2 user-defined ℃ profiles. •
Dedicated temperature profiles for COD and total phosphorous reactions are preset to 150°C
•
The total nitrogen analysis temperature is pre-set to 105°C
•
In adjustable temperature mode (50 to 150°C), the heater can be used for other samples that require different digestion temperatures
Product Code
Description
Method
•
Low temperature alert indicates that temperature is below set value
•
High temperature alert warns when temperature rises above the set value
•
Reactor has a thermal fuse that prevents overheating by disabling the heater
Range
HI 93754A-25
low range
ePA*
0 to 150 mg/L(ppm)
Multi-vial reagent packs
HI 93754B-25
medium range
ePA*
0 to 1500 mg/L(ppm)
HI 93754C-25
high range
ePA*
0 to 15000 mg/L(ppm)
HI 93754D-25
low range
Mercury-free***
0 to 150 mg/L(ppm)
Hanna COD reagents are supplied in boxes of 25 vials complete with a Hanna certificate of quality.
HI 93754E-25
medium range
Mercury-free***
0 to 1500 mg/L(ppm)
HI 93754F-25
low range
iso15705**
0 to 150 mg/L(ppm)
HI 93754G-25
medium range
iso15705**
0 to 1000 mg/L(ppm)
HI 93754H-25
low range
-
0 to 150 mg/L(ppm)
*
Heater block temperature is continuously evaluated and displayed on the LCD
Countdown timer shows time remaining until heating element shuts off •
A three hour countdown timer is ideal for timed digestion
•
The sound of a ‘beep’ indicates when the timer has expired and the heating element turns off
Method with chromium- sulphuric acid is officially recognized by EPA for wastewater analysis.
**
The HI 93754F-25 and HI 93754G-25 method follows the official method ISO 15705.
***
This method is recommended for general purpose analysis with no chloride interference.
•
To operate in infinity mode, the timer can be used without the shut-off feature
Visual power indication
Safety precautions
•
Green LED indicates power on
•
•
Blinking red LED warns if heater exceeds 50˚C
•
Yellow LED indicates heating is active
Specifications
www.hannaplus.com for latest and more complex products
Product Code
HI 83214
Temperature Of Reaction
selectable, 105°C or 150°C
Temperature Stability
±0.5°C
Capacity
25 vials (dia 16 x 100 mm), 1 receptacle for a reference thermometer with stainless steel probe
Accuracy
±2°C (@25°C)
Warm Up Time
approx. 30 minutes, depending on selected temperature
Operating Mode
timed (0 to 120 minutes) or infinity mode
Timer Range
0 to 120 minutes with acoustic alarm and automatic shut-off
Block
aluminum
Environment
5 to 50°C
Power Supply
100 Vac, 50/60 Hz; 230 Vac; 50 Hz; 250W; 2A fuse (See Chart)
Dimensions
190 x 300 x 95 mm
Weight
4.8 kg
For optimum safety, the block heater should always be used with a safety shield or other physical barrier placed between samples under test and operator
Accessories
Stainless steel test tube rack to hold 25 COD tubes HI 740216
Call: +46 300 404018 or email: info@hannanorden.com
Bench top safety shield for use with HI-9800 series COD reactor/digestor HI 740217
chemical oxygen demand
chemical oxygen demand
High Range (HR): 0 to 15000 mg/L
Mercury-free reagents for analysing samples without chloride are also available.
The Hanna HI 839800 thermo-reactor is an easy to use test tube heater with the capacity to perform up to 25 simultaneous digestions. Complete with a countdown timer, it can be used for timed or infinity testing procedures.
Hanna COD reagents are safe for operators and the environment
Medium Range (MR): 0 to 1500 mg/L or 0 to 1000 mg/L
All reagents are traceable to NIST SRM® 930.
part no: HI 839800
25 vial heater with timer
Certified COD reagents
COD levels vary depending on the application and process measuring points.
25 vial thermo-reactor
Water
Water
chemical oxygen demand
COD • COD • COD • COD
15
• Robust pocket-sized testers
Water Checktemp Range
PRIMO series
Great everyday testers for TDS and conductivity
Supplied with • Batteries • Instructions
• Direct probe connection
Specifications
• Automatic Temperature Compensation
The Primo pocket TDS tester has a measurement range of 0 to 1999ppm (mg/L)
They are ideally suited to the rigorous demands of water quality professionals who will appreciate the practicality of the clear, easy to read LCD for demonstrating the before and after results of conditioning and filtration systems.
• Choose from TDS or EC
• Automatic calibration
Primo
The pocket sized Primo testers provide a fast and dependable way to measure the total dissolved solids (TDS) or conductivity in water samples.
Product Code
PRIMO
PRIMO5
0 to 1999 ppm (mg/L)
0 to 1999 µS/cm
Resolution
1 ppm (mg/L)
1 µS/cm
Accuracy
±2% F.S.
±2% F.S.
HI-70032P
HI-70031P
automatic, at 1382 ppm
automatic, at 1413 µS/cm
Range
Calibration Solution Calibration Temperature Compensation
Automatic, 0 to 60°C , ß=2%/°C
Battery Type Battery Life Environment
Pocket Thermometers
Primo series
Pocket testers
Water
Pocket EC & TDS
TDS • conductivity • TDS
Primo 5
2 x 1.5V approx. 200 hours; auto-off after 5 minutes of non-use 0 to 50°C ; RH max 95%
Dimensions
180 x 50 x 25 mm
Weight
50 g
Primo 5 conductivity tester has a measurement range of 0 to 1999uS/cm and 1us/cm resolution
Operation and maintenance are straightforward Operate
Calibrate
1. Primo and Primo 5 use a single
1. Simply press and hold the button for a few
button at the top of the meter.
conductivity 16
meter is powered and ready for use.
2. Open a sachet of Hanna calibration solution and dip the probe directly into the sachet.
3. Within seconds the meter recognises the
calibration solution and will calibrate itself.
Temperature is compensated automatically to ensure the readings are consistent with the standard or reference temperature.
Latest details on top selling lines and popular products online
www.hannanorden.com
www.hannanorden.com
conductivity
2. Press the button once and the
seconds and the meter automatically enters calibration mode.
17
conductivity • conductivity
EC TDS & ℃ low and high range
te ste
3 in 1 advanced waterproof testers that float
rs Which model? Dual level display for simultaneous readings
Models available Low range: HI 98311 High range: HI 98312
Easy to use two button operation
Bright floating waterproof case
Both models are designed for ease of use with a floating, waterproof case and offer the following features: Measurement of conductivity (EC) and total dissolved solids (TDS)
•
Automatic calibration and temperature compensation
•
Replaceable electrodes
Direct contact temperature probe
The difference between the two models lies purely in their range. The choice depends on your application.
Example Low range tester: great for measuring clean water and tap water High range tester: ideal for testing waste water and boiler water
Low Range: HI 98311
Pocket Thermometers
With an impressive range of features, these Hanna pocket testers are unmatched in the marketplace for EC/TDS and temperature measurement.
•
part no: HI 98311 (Low LR) part no: HI 98312 (High HR)
Water
Water Checktemp Range
conductivity
Low range tester for measuring samples such as clean water and tap water.
Replaceable graphite electrode snap-in connector Removable safety cap
Illustration shows Low Range Tester HI 98311
Specifications Product Code
Range
HI 98312
0 to 3999 µS/cm
0.00 to 20.00 mS/cm
TDS
0 to 2000 ppm
0.00 to 10.00 ppt
0.0 to 60.0°C
0.0 to 60.0°C
EC
1 µS/cm
0.01 mS/cm
TDS
1 ppm
0.01 ppt
Temperature
0.1°C
0.1°C
EC
±2% F.S.
±2% F.S.
TDS
±2% F.S.
±2% F.S.
Temperature
±0.5°C
±0.5°C
automatic, 1 point at 1413 µS/cm or 1382 ppm
automatic, 1 point at 12.88 mS/cm or 6.44 ppt
Temperature
conductivity
Resolution
18
Product uses
Accuracy @ 20℃
Calibration
• • •
Like photography...
send in photos…
Boilers and cooling towers Hydroponics and greenhouses Font solution measurement in litho printing
vote for your favourites…
TDS Conversion Factor Temperature Compensation Environment Battery Type
High range tester for measuring samples such as waste water and boiler water
adjustable from 0.45 to 1.00 automatic, with ß adjustable from 0.0 to 2.4% / °C 0 to 50°C ; RH max 100% 4 x 1.5V with BEPS
Battery Life
approx. 100 hours of continuous use, auto-off after 8 minutes of non-use
Dimensions
163 x 40 x 26 mm
Weight
High Range: HI 98312
100 g
www.hannacalendar.com visit our website www.hannacalendar.com
conductivity
HI 98311 EC
19
conductivity • conductivity
Portable EC TDS pH & ℃ low & high range models
Designed for optimum consistency and reproducibility The HI 991301 HR combination meter for conductivity offers a great range of user selectable features to deliver greater consistency and reproducibilty. Different TDS factors ranging from 0.45 to 1.00
•
Temperature coefficients (ß) ranging from 0.0 to 2.4%
part no: HI 991301 (High HR) part no: HI 991300 (Low LR)
High precision with consistent deliverability
Accessories designed for tough conditions Both the HI 1288 multiparameter probe and protective rubber boot are designed for tough conditions – adding great value to both high and low range models.
The HI 991301 and HI 991300 high and low range instruments have both been designed to offer pH, conductivity, total dissolved solids and temperature measurements in a slim, lightweight portable unit. For optimum precision testing from purified water to measurement in brine, simply select the meter with the conductivity range that will work best with your application.
HI 1288 multiparameter probe
Protective rubber boot
•
Amperometric conductivity probe with DIN connector and 1.2m cable
Multi level LCD display
•
Built in temperature sensor
Available in either orange or blue, these rubber boots offer good shock protection for use out in the field.
•
Displays current measurement simultaneously with current temperature
•
Sensor has PVC body with ‘keep clean’ design
•
Clear tutorial messages on screen guide the user intuitively through the range of calibration buffers and temperature scale options
•
Portable EC TDS pH & ℃ low & high range models
Water
Water
part no: HI 991301 (High HR) part no: HI 991300 (Low LR)
conductivity • conductivity
Product code: Orange: HI 710023 Blue: HI 710024
Automatic one or two point calibration Simple two button operation is easy to use single-handedly – perfect for use out in the field
Supplied with HI 991301 & HI 991300 •
HI 1288 multi-parameter probe
•
•
Starter pack of buffer, calibration and cleaning solutions
Product Code
HOLD button freezes readings on display for manual recording
• •
20
www.hannanorden.com
0.00 to 20.00 mS/cm
0 to 2000 ppm (mg/L)
0.00 to 10.00 ppt (g/L)
Temperature
Accuracy
0.0 to 60.0°C 0.01 pH
EC
1 µS/cm
TDS
1 ppm
±0.01 pH
EC
±2% F.S.
TDS
±2% F.S.
•
Includes pH, EC/TDS and temperature in one convenient rugged handle
•
Solid state amplifier integrated into the probe to ensure against interference from transient electrical noise
info@hannanorden.com
+46 300 404018
±0.5°C selectable 0.45 to 1.00 with 0.01 increments (default 0.50) automatic at 1 or 2 points with 2 sets of memorized standard (pH 4.01/7.01/10.01 or 4.01/6.86/9.18)
pH Calibration
automatic, 1 point at 1382 ppm (CONV 0.5) at 1500 ppm (CONV 0.7)
EC/TDS Calibration
Temperature Compensation
pH EC/TDS
Automatic Automatic with selectable ß from 0.0 to 2.4%/°C with 0.1 increments
Probe
HI 1288, pH/EC/TDS/T, DIN connector, 1 m (3.3’) cable (included)
Power Supply
4 x 1.5V AAA / approx. 500 hours of continuous use
Environment
0 to 50°C ; RH max 100%
Dimensions Weight
www.hannanorden.com
0.01 ppt
pH
TDS Conversion Factor
Illustrated: HI 991301 High Range test EC, pH, TDS and °C in one slim, rugged unit
0.01 mS/cm
0.1°C
Temperature
Multi-parameter probe HI 1288:
HI 991300 Low Range model
0 to 3999 µS/cm
TDS
Temperature
Automatic temperature compensation
HI 991300
EC
pH Resolution
Easy to clean and keep clean
Battery error prevention system alerts user of low battery which could adversely affect readings
0.00 to 14.00 pH
Range
Instructions
Rated for IP67 conditions
HI 991301
info@hannanorden.com
150 x 80 x 36 mm 210 g
+46 300 404018
conductivity
conductivity
•
HI 991300 pH
Batteries
Slimline waterproof housing •
Specifications
21
Waterproof EC meter multi range
conductivity • conductivity
part no: HI 9033
conductivity • conductivity
Waterproof EC meter multi range part no: HI 9033
Water
Water
Designed for use out in the field Slimline waterproof casing
Large dual level LCD •
Simultaneous EC and temperature readings
•
Easy to read display in tough conditions
•
On-screen tutorial messaging
Designed to support optimum working order •
9v battery with approx 100 hours continuous use
•
BEPS battery error prevention system
Automatic temperature compensation
Rugged conductivity probe
Rubberised keyboard
22
•
Buttons are intuitively labelled for ease of use
Need a spare probe?
With the ability to select from multiple conductivity ranges, it can measure samples from deionised water through to brine without having to switch or recalibrate the probe – ideal for use out in the field.
Quote
Measurements are performed with automatic temperature compensation which adjusts for the effects of temperature on the probe. The instrument also features the Hanna battery error prevention system to help ensure it is in optimum working order before going out on location.
Select chosen range from multiple conductivity options
part n umber
HI 76 302W
Supplied with • HI 76302W EC probe
• Instructions
• Battery
• Rugged carrying case
Hanna is a global brand renowned for high precision and great value
•
Includes 1m cable and DNC connection
•
Supplied as standard
Specifications Product Code
HI-9033
Range
0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm;
Resolution
0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm
Accuracy
±1% F.S. (excluding probe error)
Calibration
manual, 1 point
Temperature Compensation
automatic, 0 to 50°C with ß=2%/°C
Probe
HI-76302W, ATC, with 1 m (3.3’) cable (included)
Battery Type / Life
1 x 9V / approx. 100 hours of continuous use
Environmen
0 to 50°C ; RH max 100%
Dimensions
196 x 80 x60 mm
Weight
425 g
Our products are competitive, innovative and popular
conductivity
conductivity
The HI 9033 is a rugged meter designed to withstand extended use in wet, humid, dusty or muddy conditions.
•
23
conductivity • conductivity
Multiparameter EC/TDS˚C/NaCl
Water
With a rugged waterproof casing, they are ideal for use out in the field as well as internal laboratory testing.
Waterproofed, rugged ergonomic casing – designed to survive harsh conditions of field use
Probe connector located on top of instrument for ease and efficiency
Data logging up to 500 records with USB port featured as standard with HI 98360 model
Clear tutorial messaging guides the user through calibration, operation and setup
•
Battery error prevention system alerts user if power is low
•
· Data logging up to 500 records with USB port for data transfer included with HI 98360
HI 9835 is ideal for testing in tough conditions
· Choose between automatic and manual temperature compensations to match operating requirements · Meter can be connected to a 12 Vdc power supply (optional)
Supplied with
Large backlit LCD display •
Added benefits
% battery displayed on start up
HI 9835
HI 98360
· HI 76309 conductivity probe with internal temperature sensor on 1m cable
· HI 76309/1.5 conductivity probe with internal temperature sensor on 1.5m cable
· Batteries
· Batteries
· Instructions
· Instructions
· Rugged carrying case
· Rugged carrying case
Need a probe? spare
Quote
part n
umber HI 76 309 or HI 76 309/1.5
Designed to allow simultaneous sampling of electro conductivity (EC), total dissolved solids (TDS) salinity (NaCl) and temperature, these portable meters are ideal for measuring conductivity in testing or pressured environments.
rugged waterproof
p
Water
part no: HI 98360 part no: HI 9835
ta r o
Rugged and highly versatile, these two high precision instruments each combine the four important parameters needed to measure conductivity in one high precision multiparameter instrument.
Multiparameter EC/TDS/˚C/NaCl
e bl
part no: HI 98360 part no: HI 9835
Rugged all in one conductivity meter with datalogging
conductivity • conductivity
Specifications Product Code
Rubberised keyboard with clearly marked buttons for intuitive use •
24
The HI 76309 conductivity and temperature probe features a PVC body with a stainless steel four ring design to deliver high accuracy over a broader conductivity range. The four ring construction is designed to ensure the probe is immune to polarisation and fouling for longer periods of time. Combined with either a 1m or 1.5m cable, this probe makes the meter particularly popular for use out in the field.
•
Auto range of EC and TDS modes automatically set meter to scale with highest possible resolution
Resolution
• • • •
Cell constant range from 0.500 to 1.700
•
Selectable TDS factor of 0.40 to 0.80
•
0.00 to 14.99 ppm (mg/L); 15.0 to 149.9 ppm (mg/L); 150 to 1499 ppm (mg/L); 1.50 to 14.99 g/L; 15.0 to 100.0 g/L up to 400.0 g/L (actual TDS)
NaCl
0.0 to 400.0%
0.0 to 400.0%
Temperature
9.9 to 120.0°C
0.0 to 60.0°C
EC
0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm
0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm
TDS
0.01 ppm (mg/L); 0.1 ppm (mg/L); 1 ppm (mg/L); 0.01 g/L; 0.1 g/L
0.01 ppm (mg/L); 0.1 ppm (mg/L); 1 ppm (mg/L); 0.01 g/L; 0.1 g/L 0.1%
0.1°C
0.1°C
EC
±0.5% of reading
±1% ±(0.05 µS/cm or 1 digit)
TDS
±0.5% of reading
±1% ±(0.03 ppm or 1 digit)
NaCl
±0.5% of reading
±1%
Temperature
±0.4°C
±0.4°C
EC
automatic, 1 point, with 6 memorized values (84, 1413, 5000, 12880, 80000 and 111800 µS/cm)
automatic, 1 point, with 6 memorized values (84, 1413, 5000, 12880, 80000 and 111800 µS/cm)
NaCl
1 point, with HI 7037 calibration solution (not included)
1 point, with HI 7037 calibration solution (not included)
Temperature
2 point, at 0 and 50°C
2 point, at 0 and 50°C
Temperature Compensation
automatic or manual, 0 to 60°C ; can be disable for measuring actual EC and TDS
automatic or manual, 0 to 60°C ;can be disable for measuring actual EC and TDS
Temperature Coefficient
adjustable from 0.00 to 6.00%/°C (EC and TDS only)
adjustable from 0.00 to 6.00%/°C (EC and TDS only)
TDS Conversion Factor
adjustable from 0.40 to 0.80
adjustable from 0.40 to 0.80
Promotes greater stability over a broader measuring range
Data Logging
up to 250 samples
Probe
HI-76309/1.5, with 1.5 m (4.9’) cable (included)
HI 76309, 4-ring probe, K=1 nominal, built-in temperature sensor (included)
Equipped with an embedded temperature sensor
Power Supply
4 x 1.5V AA batteries (included) or 12 Vdc input; auto-off after 5 mins of non-use (can be disabled)
4 x 1.5V AA batteries (included) or 12 Vdc input; auto-off after 5 mins of non-use (can be disabled)
Environment
0 to 50°C ; RH max 100%
0 to 50°C (; RH max 100%
Immunity to polarisation and falling
Dimensions
196 x 80 x60 mm
196 x 80 x60 mm
Weight
500 g
500 g
4-ring probe design
Temperature reference from 20 to 25°C
0.00 to 14.99 ppm (mg/L); 15.0 to 149.9 ppm (mg/L); 150 to 1499 ppm (mg/L); 1.50 to 14.99 g/L; 15.0 to 100.0 g/L up to 400.0 g/L (actual TDS)
0.1%
HI 98360 portable conductivity meter with datalogging
•
TDS
NaCl
Accuracy
Temperature coefficient from 0.00 to 6.00°C
0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC)
Temperature
Auto end point automatically freezes the display once a stable reading is reached
Selectable conductivity and TDS measurement
HI-9835
0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC)
For temperature calibration, contact our Hanna calibration lab
Calibration
Call: +46 300 404018 or email: info@hannanorden.com
conductivity
conductivity
Four ring probe design for added stability over broader measuring range
Range
HI-98360 EC
25
DO • DO • DO • DO • DO
e
Large clear display for easy readout
Help and tutorial display messaging
Designed to support accurate, efficient testing
DO range up to 300% plus temperature compensation
Positive locking system ensures cuvette is positioned in the same place every time it is placed into the measurement cell
Automatic calibration check
•
Useful timer function
•
Auto shut off to save battery life
•
Battery error prevention system to confirm functionality each and every time the instrument is switched on
Main benefits •
Allows altitude compensation up to 4000m
•
Salinity compensation up to 80g/L
•
Automatic calibration in air
•
Two spare membranes included as standard
•
Hard carrying case and instructions provided
Uses Hi 96732-11 standards
Automatic calibration check
Waterproof casing is ideal for use in the laboratory or out on location
GLP features
Polarographic probe included as standard features built-in temperature compensation and removable, protective membrane cover
Specifications Product Code
Range
GLP features
0.0 to 300.0%
Temperature
0.0 to 50.0°C
O2
0.01 mg/L
% Saturation O2
0.1%
Range
0.0 to 10.0 mg/L (ppm)
Temperature
0.1°C
Resolution
0.1 mg/L (ppm)
O2
±1.5% F.S.
Accuracy
±0.2 mg/L ±3% of reading
% Saturation O2
±1.5% F.S.
Light Source
light emitting diode
Temperature
±0.2°C (excluding probe error)
Light Detector
Silicon photocell with narrow band interference filter @ 466 nm
Fact
Modified Winkler Method.
Environment
0 to 50°C ; max 95% RH noncondensing
Power Supply
9V battery
Auto-Shut off
after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Dimensions
192 x 104 x 69 mm
Weight
360 g
Dissolved oxygen is one of the most important parameters in aquatic systems. The amount of oxygen that can dissolve in pure water is inversely proportional to the temperature of the water; ie the warmer the water, the less dissolved oxygen will be present.
Helping you care clean and maintain your instruments
Accuracy
•
Waste water treatment
•
Quality control for drinking water
•
Fish farming
Calibration
automatic, in air, at 100%
Temperature Compensation
automatic, 0 to 50°C
Altitude Compensation
0 to 4000 m (resolution 100 m)
Salinity Compensation
0 to 80 mg/L (resolution 1 g/L)
Probe
HI-76407/2 with 2 m cable
Power Supply
3 x 1.5 AA batteries / approx. 200 hours of continuous use without backlight (50 hours with backlight)
Environment
0 to 50°C ; RH max 100%
Dimensions
185 x 72 x 36 mm
Weight
300 g
Choose from our wide range of accessories and solutions
dissolved oxygen
0.00 to 45.00 mg/L
% Saturation O2
HI 96732
Resolution
Ideal for
HI 9146-04 O2
Product Code
Method
Developed for DO and temperature measurement in water, wastewater and applications such as fish farming, it also allows compensation for altitude and salinity.
Low battery indicator
Water
Specifications
dissolved oxygen
Robust waterproof casing designed for field applications Backlit display is helpful for use in low ambient light levels
The photometer benefits from a range of features to help ensure the instrument is in optimum working order each and every time it is used:
26
2m cable for ease of use
The HI 9146 portable meter is a rugged water-resistant instrument offering an extended range for measuring dissolved oxygen and temperature.
Delivering high precision results yet at the same time, simple to operate, this is a photometer that will provide aquaculturists and fish farming operations with consistent, reliable results.
Content of dissolved oxygen in surface, feed, natural and waste water is measured in the 0.0 to 10.0 mg/L (ppm) range
For best results, the cuvette is made from special optical glass and benefits from a wide mouth for ease of sampling
part no: HI 9146-04
Water
Lightweight and portable, the Hanna photometer for dissolved oxygen is ideal for applications where liquid sampling is required either in the lab or out in the field.
Testing in the field
e
t
r o p
Sample test with high precision
bl
l b a
Portable dissolved oxygen meter
rt a
part no: HI 96732
•
DO • DO • DO • DO • DO
po
Photometer for dissolved oxygen
27
ORP / Redox • ORP / Redox
Pocket testers
ORP / Redox • ORP / Redox
ORP/Redox & pH part no: HI 98121
ORP/Redox & pH part no: HI 98121 part no: HI-98120
Floating waterproof casing helps prevent accidental loss of meter during testing in difficult conditions
Combination ORP/Redox & pH HI 98121
Battery % level at start up and stability indicator helps ensure tester is in optimum working order
ORP/Redox pH & °C combination tester
Cartridge electrode – exclusive to Hanna •
•
Combination pH and Redox / ORP electrode (HI 98121 only)
ORP/Redox HI 98120 Waterproof ORP/Redox and temperature meter
Supplied with:
•
Automatic temperature compensation
pocket, portable and precise
•
Automatic calibration (HI 98121 only)
part no: HI-98120
Offering users a choice of ORP/Redox measurement combinations, these two testers are popular options for operators carrying out spot checks or testing on location.
Exposed stainless steel temperature sensor facilitates faster and more accurate temperature measurement
Displays simultaneous readings
HOLD function freezes readings for ease of recording
Electrode replacement with stainless steel round connector means there are no pins to bend or break during replacement
•
•
Waterproof combination testers
Dual level LCD screen
ORP/Redox
Water
Water
ORP/Redox
Pocket testers
Designed for use out in the field and in murky conditions, the meters are sealed against humidity, float in water and have a bright green casing making them easily visible in low light levels.
Specifications
HI 98121 (ORP/Redox & pH) •
HI 73127 pH electrode
•
HI 73128 electrode removal tool
•
Product Code Redox / ORP Range
ORP
Batteries & instructions Resolution
28
HI 73120 ORP/Redox electrode
•
HI 73128 electrode removal tool
•
Batteries & instructions
Accuracy
HI 98121 ±1000 mV
-
-2.00 to 16.00 pH
-5.0 to 60.0°C
-5.0 to 60.0°C
1 mV
1 mV
-
0.01 pH
Temperature
0.1°C
0.1°C
ORP
±2 mV
±2 mV
-
±0.05 pH
pH
pH Temperature
±0.5°C
ORP Calibration
pH
Temperature Compensation Electrode Battery Type Battery Life Environment Dimensions Weight
www.hannanorden.com
Spare electrodes Easy to replace electrode cartridges with sturdy snap-in connections.
±0.5°C
ORP / Redox
ORP / Redox
HI 98120 (ORP/Redox) •
pH Temperature
HI 98120 ±1000 mV
factory calibrated automatic, one or two points with two sets of memorized buffers (pH 4.01 / 7.01 / 10.01 or 4.01 / 6.86 / 9.18)
-
Automatic for pH readings HI 73120 replaceable ORP electrode (included)
HI 73127 replaceable pH electrode (included); fixed ORP sensor
4 x 1.5V approximately 250 hours of continuous use; auto-off
HI 73127
HI 73120
pH electrode
ORP/Redox electrode
-5 to 50°C ; RH max 100%
Use with:
163 x 40 x 26 mm
HI 98121
info@hannanorden.com
Use with: HI 98120
100 g
+46 300 404018
www.hannanorden.com
info@hannanorden.com
+46 300 404018
29
Water Checktemp Range
Go-anywhere pH testers
Each meter offers a range of great features with high levels of accuracy.
The difference is in their resolution and accuracy
Dual LCD screen displays pH and temperature simultaneously
For 0.1 pH resolution and ±0.1 pH accuracy: select HI 98127
Temperature given in ˚C or ˚F
For 0.01 pH resolution and ±0.05 pH accuracy: select HI 98128
•
Robust, replaceable electrodes
•
Proximity of exposed temperature sensor to pH electrode guarantees greater accuracy in temperature compensated readings
•
Designed to calibrate direct into Hanna buffer solution sachets
•
Battery % displayed on start up with battery error prevention system (BEPS) to support optimum operation
HI-98127 Offers 0.1 pH resolution and +/- 0.1 pH accuracy
Automatic buffer recognition and calibration
part no: HI 98127 part no: HI 98128
Rubberised, easy to use two button operation Waterproof casing designed to float if dropped in water
Main benefits •
Waterproof pH & ℃
Tactile grip casings
Replaceable electrodes help prolong the life of the meter
Water
Waterproof, accurate and portable, these handy little pocket meters are true ‘goanywhere’ pH testers with replaceable electrodes.
pH • pH • pH • pH • pH et ck rs po ste te
Pocket Thermometers
pH • pH
HI-98128 Offers 0.01 pH resolution and +/- 0.05 pH accuracy
Electrode features stainless steel round connector ensuring there are no pins to bend or break during replacement Exposed temperature sensor provides fast response time Removable safety cap
Illustration shows High Range Tester HI 98128
Soluti
ons
See pa ge 3 6 for a choice of buf fer and ca libratio n solutio ns.
Specifications Product Code Range
Resolution
Accuracy
HI 98127
HI 98128
pH
-2.0 to 16.0 pH
-2.00 to 16.00 pH
Temperature
-5.0 to 60.0°C
-5.0 to 60.0°C
pH
0.1 pH
0.01 pH
Temperature
0.1°C
0.1°C
pH
±0.1 pH
±0.05 pH
Temperature
±0.5°C
±0.5°C
pH Calibration Temperature Compensation Battery Type Battery Life
30
Dimensions Weight
www.hannaplus.com for latest and more complex products
v
HI 73127 pH electrode, HI 73128 electrode removal tool, batteries and instructions
automatic, at 1 or 2 points with 2 sets of memorised buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18) Automatic 4 x 1.5V with BEPS approx. 300 hours of continuous use; auto-off after 8 minutes of non-use -5 to 50°C ; RH max 100% 163 x 40 x 26 mm 100 g
pH
pH
Environment
Both models are supplied with:
31
pH • pH • pH • pH • pH t e ck ers o p st te
part no: HI 98129 (low range)
HI 98129 and HI 98130 are waterproof testers that offer high accuracy pH, conductivity, total dissolved solids and temperature measurements in a single tester. No more switching between meters for routine measurements: •
• •
These floating, waterproof combination testers have an easy to read LCD and automatic shut-off
•
pH and EC/TDS readings are automatically temperature compensated
•
The EC/TDS conversion factor is user selectable as well as the temperature compensation coefficient
•
Both testers feature a replaceable pH electrode cartridge together with an EC/TDS graphite electrode
•
Automatic shut-off helps preserve battery life
•
Replaceable pH cartridge extends life of the tester – when pH sensor is exhausted, simply replace it with a new one
part no: HI 98129 (low range)
Multiparameter pH, EC, TDS
Automatic 1 or 2 point pH calibration Rubberised keyboard
•
•
Easy switch between Celsius & Fahrenheit readouts
•
HOLD function
pH and temperature displayed simultaneously
•
Automatic temperature compensation
•
BEPS Battery Error Prevention System
Floating waterproof casing with tactile grip makes testing easier and less of a headache!
0 to 3999 uS/cm; 0 to 2000 ppm For high range: select HI 98130 0.00 to 20.00 mS/cm; 0.00 to 10.00 ppt
Supplied with •
HI 73127 pH electrode
•
HI 73128 electrode removal tool
•
Batteries
•
Instructions
•
Easy to replace pH electrode cartridge with sturdy snap-in connector means there are no pins to bend or break
We manufacture a wide range of solutions for the care, cleaning and calibration of your electrodes. For details see page 36. Illustration shows Low Range Tester HI 98129
LCD indicates the percentage of battery power remaining at startup
Removable safety cap HOLD function
High accuracy EC/TDS graphite probe
Standard or N.I.S.T buffer clibration
The graphite conductivity probe provides greater accuracy because it cannot be contaminated by salt deposits in the solution.
Ensures reliable EC and TDS measurements. ATC symbol is shown when active
Automatic calibration is performed with 2 sets of memorised buffers for greater accuracy
Adjustable temperature coefficient factor
Adjustable TDS ratio
Users can choose between different BETA (B) factors for precise temperature compensated measurements
Specifications
The HOLD function “freezes” the LCD display temporarily
For measurement accuracy, users can choose between different conductivity to TDS conversion factors
Latest details on top selling lines and popular products online
The exposed temperature sensor provides fast response times and guarantees highly accurate Temperature compensated readings.
Product Code
HI 98129 pH
Range
EC
0 to 3999 µS/cm
0.00 to 20.00 mS/cm
TDS
0 to 2000 ppm
0.00 to 10.00 ppt
Temperature
0.0 to 60.0 ℃ / 30.0 to 140.0 ℉
pH Resolution
0.01
EC
1 µS/cm
TDS
1 ppm
Temperature
pH Automatic EC/TDS Automatic
±2% F.S. ±0.5 ℃ / ±1 ℉ 1 or 2 points with 2 sets of memorised buffers, (pH 4.01/7.01/10.1 or pH 4.01/6.86/9.18) 1 point at 1413 µS/c, or 12.88 mS/cm
Automatic Temperature Compensation Battery Type / Life
For spares quote part number: HI 73127
www.hannanorden.com
Yes (4) 1.5V / 100 hours
Battery Error Prevention System
Yes
Auto-off Dimension / Weight
0.01 ppt
±0.05
EC/TDS Temperature
Calibration
0.01 mS/cm
0.1℃
pH Accuracy
HI 98130 0.00 to 14.00
After 8 minutes 163 x 40 x 26 mm / 100 g
www.hannanorden.com
pH
pH
•
For low range: select HI 98129
Solutions
Instability & ATC indicators
32
Large LCD display
Quick and easy to operate
On-screen battery life
Calibrate direct into Hanna buffer solution sachets
part no: HI 98130 (high range)
Low or High range conductivity? Simply select the model that is most appropriate for your testing range:
•
•
pH/TDS/Conductivity
Pocket Thermometers
part no: HI 98130 (high range)
pH • pH • pH • pH • pH
Water
Water Checktemp Range
pH/TDS/Conductivity
33
pH • pH • pH • pH • pH
Water Checktemp Range
Portable pH & ORP
pH • pH • pH • pH • pH
Portable pH & ORP part no: HI 9124
part no: HI 9125
part no: HI 9125
Rugged, waterproof pH and Redox/ORP
HI 9124 and HI 9125 are rugged, high specification portable meters. Both measure pH but the HI 9125 offers the additional advantage of being able to measure ORP/Redox.
great for field application
for pH: select HI 9124
Heavy-duty waterproof casing combined with latest microprocessor technology makes these meters ideal for delivering laboratory grade results and accuracy under harsh industrial conditions.
HI 9124 offers high specification pH testing in a strong portable casing
Automatic temperature compensation Extended pH and temperature range clearly displayed on large LCD display
for pH & ORP: select HI 9125
Fully automatic buffer recognition
HI 9125 measures pH plus ORP in one rugged, high specification meter using optional HI 3230B ORP/Redox electrode
Memorises pH reading and recall on display User-friendly text and graphics support calibration procedure without constant reference to a manual
HI 9124 and HI 9125 are each supplied with: HI 1230B pH electrode HI 7662 temperature probe Starter pack of buffer solutions
Rubberised keyboard
Specifications Product Code pH
100 ml plastic beaker Automatic pH calibration with five memorised pH buffer values and buffer recognition to simplify calibration
Batteries and instructions
Range
mV Temperature
Resolution
Electrodes HI 7662 stainless steel temperature sensor included as standard
Battery % remaining displayed on start up
For spare and alternative electrodes order using the following part numbers:
send in photos…
vote for your favourites…
±699.9 mV; ±1999 mV 20.0 to 120.0°C 0.01 pH
mV
-
0.1 mV; 1 mV
mV Temperature
pH Calibration
0.1°C
0.1 °C
±0.01 pH
±0.01 pH
-
0.1 mV; 1 mV
±0.4°C
±0.4 °C
automatic 1 or 2 point with 5 memorized buffer values (4.01, 6.86, 7.01, 9.18, 10.01)
Offset Calibration
±1 pH
Slope Calibration
From 80 to 108%
ORP: HI 3230B
Temperature Compensation
temperature: HI 7662
pH Electrode
We manufacture a range of solutions for the care, cleaning and calibration of your electrodes. For details see page 36.
Temperature Probe
automatic or manual, -20 to 120°C HI-1230B, double junction, gel filled, BNC connector and 1 m cable (included) HI-7662 with 1 m (3.3?) cable (included)
Input Impedance
1012 Ohm
Battery Type / Life
(3) 1.5V AAA rechargeable / approx 200 hours of continuous use (with backlight off); auto-off after 20 minutes of non-use (can be disabled)
Environment Dimensions Weight
0 to 50°C; RH max 100% 185 x 72 x 36 mm 300 g
www.hannacalendar.com visit our website www.hannacalendar.com
pH
Like photography...
HI 1230B double junction pH electrode minimises junction contamination and enhances accuracy (supplied as standard)
-20 to +120℃
pH: HI 1230B
Solutions Heavy-duty waterproof casing
HI 9125 -2.00 to 16.00 pH
0.01 pH
pH Accuracy
HI 9124 -2.00 to 16.00 pH
pH
Temperature
Battery error prevention system (BEPS)
pH
Choice of model
User-selectable calibration time-out
34
Water
Pocket Thermometers
part no: HI 9124
35
pH • pH • pH • pH • pH
Log and store data out on location
pH 9.18 buffer solution
pH 10.01 buffer solution
part no: HI 70007P
part no: HI 70009P
part no: HI 70010P
Package 25 x 20ml sachets
Package 25 x 20ml sachets
Package 25 x 20ml sachets
Package 25 x 20ml sachets
pH value @ 25℃ 6.86 pH
pH value @ 25℃ 7.01 pH
pH value @ 25℃ 9.18 pH
pH value @ 25℃ 10.01 pH
pH 6.86 buffer solution
pH 7.01 buffer solution
part no: HI 70004P
part no: HI 70006P
Package 25 x 20ml sachets pH value @ 25℃ 4.01 pH
Robust waterproof casing
•
Rubberised keyboard with easy press buttons designed for use out in the field
•
Solutions in 20ml Sachets – supplied in packs of 25
pH 4.01 buffer solution
•
Solutions in 500ml bottles:
Large clear LCD screen provides a wide range of data and support with on screen tutorial messaging
•
Auto end mode to ensure readings only taken when stable
•
GLP data is directly accessible by pressing the GLP key
•
Log-on demand holds up to 500 records
•
Data transfer to PC via USB uses optional HI 92000 software
•
pH calibration check
•
Select up to five point calibration with eight standard and two custom pH buffers
•
Exchange pH sensor for Redox/ORP sensor for mV readings
Specifications pH 9.18 buffer solution
pH 10.01 buffer solution
part no: HI 7007L
part no: HI 7009L
part no: HI 7010L
Package 1 x 500ml bottle
Package 1 x 500ml bottle
Package 1 x 500ml bottle
Package 1 x 500ml bottle
pH value @ 25℃ 6.86 pH
pH value @ 25℃ 7.01 pH
pH value @ 25℃ 9.18 pH
pH value @ 25℃ 10.01 pH
pH 4.01 buffer solution
pH 6.86 buffer solution
pH 7.01 buffer solution
part no: HI 7004L
part no: HI 7006L
Package 1 x 500ml bottle pH value @ 25℃ 4.01 pH
Product Code
Range
Resolution
Accuracy @ 20°C
Electrode maintenance solutions
Calibration
36
500ml bottle of electrode storage solution
HI 7061L 500ml bottle of general purpose cleaning solution
www.hannanorden.com
HI 7073L 500ml bottle of protein cleaning solution
HI 7074L
HI 7077L
500ml bottle of inorganic substance cleaning solution
info@hannanorden.com
500ml bottle of oil and fats cleaning solution
+46 300 404018
part no: HI 98160
A robust portable combination pH / ORP meter Strong waterproof casing and a powerful range of calibration features with logging capacity make this instrument ideal for taking measurements out in the field where accuracy and precision are of utmost importance.
Advanced accuracy with Calibration Check Up to five point calibration with eight memorised and two custom pH buffers provides the flexibility needed to adjust the calibration range for optimum accuracy and precision An electrode graph will alert the user to the electrode status If readings are taken too far out of range, a graphic signal acts as a warning sign A reminder can be set to advise when calibration is due
HI 98160 pH
-4.0 to 20.0 pH; -4.00 to 20.00 pH
ORP
±699.9; ±2000 mV
Temperature
-20.0 to 120.0°C
pH
0.1 pH; 0.01 pH
ORP
0.1 mV (±699.9 mV); 1 mV (±2000)
Temperature
0.1°C
pH
±0.1 pH; ±0.01 pH
ORP
±0.2 mV (±699.9 mV); ±1 mV (±2000 mV)
Temperature
±0.2°C (±0.4°F) excluding probe error
pH
up to five point calibration with eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and two custom buffers
ORP
automatic, two point at 0, 350 mV or three point at 0, 350, 1900 mV
Offset
±1 pH
Slope
from 80 to 110%
Supplied with
pH Electrode
HI-1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included)
Temperature Probe
HI-7662 stainless steel temperature probe with 1 m (3.3’) cable (included)
Log On Demand
500 samples
PC Connectivity
opto-isolated USB with optional HI-92000 software
Input Impedance
1012 Ohms
· Starter pack of buffer solutions
Power Supply
1.5V AAA (3) / approximately 200 hours of continuous use without backlight (50 hours with backlight). User selectable auto-off (5, 10, 20, 60 minutes or can be disabled)
· Batteries
Environment
0 to 50°C ; RH max 100%
Dimensions
185 x 72 x 36 mm
Weight
300 g
www.hannanorden.com
· HI 1230B pH electrode · HI 7662 temperature probe
· Instructions · Rugged carrying case
info@hannanorden.com
+46 300 404018
pH
pH
HI 70300L
Portable pH & ORP with Calibration Check
Solutions to calibrate and look after your pH meter and electrode
pH • pH • pH • pH • pH
Water
Water
Solutions pH
37
photometry • photometry • photometry
photometry • photometry
Pocket photometers Checker HC series
The Checker family
Hanna offers a choice of single and multiparameter photometers to meet customer demand
Hanna pocket checkers offer a cost-effective digital alternative to chemical test kits.
Choose from our full range:
Water quality can be tested and controlled quickly and accurately with these professional quality meters, but at a fraction of the cost of their more sophisticated sister meters in our photometer range.
From pocket checkers to advanced 44 parameter format • Measurements are easy to take • Results are delivered with speed and precision
HI 755 Alkalinity
Ideal for regular water testing and aquaculture hobbyists, Hanna Checkers have proved hugely popular since their For ad dition launch in 2010. al re
• Findings are clear and easy to read
Water
Water
Photometers
agent, see page 4
4
Main Benefits •
Testing is quick and easy
•
High precision results – more accurate than chemical test kits
•
Auto shut off feature means the Checker cannot be left on by mistake
•
Fully portable, fitting easily into both palm and pocket
HI 711 Total Chlorine Zero the Checker
Ideal for
Supplied with
•
Water quality testing
•
2 sample cuvettes
•
Tropical aquariums
•
Starter pack of reagents
•
Koi ponds
•
•
Reef tanks
1 x 1.5 AAA battery
•
Swimming pools
•
Instruction manual
Product Code
HI 764 Nitrite ULR Insert sample into Checker
38
Precision Light Source
Hanna is a global brand renowned for high precision and great value
HI-713
HI-736
0.00 to 2.50 ppm (mg/L)
0 to 200 ppb
0.01 ppm (mg/L)
1 ppb
0.01 ppm (mg/L)
1 ppb
3% of reading ±0.03 ppm (mg/L) @ 25°C
±4% of reading ±10 ppb @ 25ºC
±0.04 ppm (mg/L) ±4% of reading @ 25°C
±5% of reading ±10 ppb @ 25ºC
LED @ 610 nm
HI 713 Phosphate
LED @ 525 nm Silicon photocell 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type
Weight
HI-764 0 to 200 ppb
1 ppm (mg/L)
Environment
Dimensions
HI-711
±5% of reading ±5 ppm @ 25°C
Light Detector
Auto-off
HI-701
0.00 to 2.50 ppm (mg/L)
Press button for results
(1) 1.5V AAA After 10 minutes of non-use
After 2 minutes of non-use and after read 81.5 x 61 x 37.5 mm 64 g
Our products are competitive, innovative and popular
HI 736 Phosphorus ULR
photometry
photometry
Resolution
HI-755 0 to 300 ppm (mg/L)
Add reagent (Alkalinity uses liquid reagent)
Specifications
Range
HI 701 Free Chlorine
Four steps, one click, instant readout
39
photometry • photometry
Single parameter photometers
The Hanna range of single parameter photometers featured offers users a choice of instruments dedicated to the measurement of one chosen parameter. Choose between the standard or low range options for free chlorine or select our combined free and total chlorine photometer, to suit your individual application.
Dedicated chlorine testing
The series features a large dual level LCD display and an advanced optical system together with the renowned Hanna calibration check to optimise working performance.
•
Measurement cell is designed with larger neck making it easier to add samples and reagent
•
Positive locking system ensures cuvette is in the same position every time it is placed in the measurement cell
With the Hanna calibration check validation function, users can verify the performance of the meter quickly and easily at any time. Using Hanna NiST traceable standards, it takes just a few moments to check the accuracy of the instrument and to recalibrate as and when necessary.
Standards
All new instruments are factory calibrated at source and the electronic and optical design of the Hanna photometers minimises the need for frequent calibration. The Hanna calibration check further minimises the frequency with which instruments need to be returned to the calibration laboratory for full servicing.
Order Code
HI 96701 Free Chlorine
HI 96701-11
HI 96762 Free Chlorine LR
HI 96762-11
HI 96711 Free & Total Chlorine
HI 96711-11
Reagents Hanna offers a range of reagents to be used with our instruments to ensure optimum results and working performance. For details see pages 44-45.
Low Range 0.000 to 0.500 mg/L (ppm)
• Lamp and filter measuring system is protected from dust or dirt by a transparent cup • Waterproof casing Large dual level LCD
•
• 9 v battery • Instructions • Reagents and standards not included
•
Clear tutorial messages displayed on LCD to support users through routine operations Low battery warning ensures instrument remains in optimum working order Auto shut-off turns meter off after 10 minutes of non-use
• Cal Check facility enables users to validate and calibrate in a few simple steps •
Date of last calibration is clearly displayed helping users to schedule regular routine calibrations as part of good laboratory practice
For temperature calibration, contact our Hanna calibration lab
Free & Total combined
Specifications Product Code
HI 96701
HI 96762
HI 96711
Parameter
Chlorine, Free
Chlorine, Free
Chlorine, Free and Total
Range
0.00 to 5.00 mg/L
0.000 to 0.500 mg/L
0.00 to 5.00 mg/L
Resolution
0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L
0.001 mg/L
0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L
Accuracy
±0.02 mg/L @ 1.00 mg/L
±0.020 mg/L ±3% of reading @ 25°C
±0.020 mg/L ±3% of reading @ 25°C
Light Source
Tungsten lamp
Tungsten lamp
Tungsten lamp
Light Detector
Silicon photocell with narrow band interference filter @ 525nm
Silicon photocell with narrow band interference filter @ 525nm
Silicon photocell with narrow band interference filter @ 525nm
Method
Adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G
Adaptation of the Standard Method 4500-Cl G
Adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G
Environment
0 to 50°C ; Max 95% RH non-condensing
0 to 50°C ; RH max 95% non-condensing
0 to 50°C ; RH max 95% non-condensing
Battery Type / Life
(1) 9V/approx. 200 hours continuous use
(1) 9V/approx. 200 hours continuous use
(1) 9V/approx. 200 hours continuous use
Auto-Off
After 10 min. of non-use in measurement mode
After 10 min. of non-use in measurement mode
After 10 min. of non-use in measurement mode
Dimensions
192 x 104 x 69 mm
192 x 104 x 69 mm
192 x 104 x 69 mm
Weight
360 g
360 g
360 g
Call: +46 300 404018 or email: info@hannanorden.com
photometry
• 2 x sample cuvettes
•
• Easy to use buttons with intuitive instructions
HI 96711 Free and Total Chlorine combined photometer The HI 96711 photometer measures the free and total chlorine content in water and wastewater.
With the ability to detect free chlorine in dilutions as low as 0.000 to 0.500 mg/L (ppm), this meter is particularly useful in applications where water and products are being produced for human consumption.
All three models are supplied with
Free chlorine Range: 0.00 to 5.00 mg/L (ppm)
The HI 96701 photometer for free chlorine measures the free chlorine content in water samples in the 0.00 to 5.00 mg/L (ppm) range.
The HI 96762 has been specially developed to measure particularly low concentrations of free chlorine in water.
photometry
Product
Hanna HI 96701 photometer for Free Chlorine
HI 96762 Low Range Free Chlorine photometer
40
Order details for standards to use with these meters:
Lightweight, portable and easy to use, they are ideal for use out in the field where highly accurate testing of one parameter is required to meet stringent requirements.
Cuvette is made from special optical glass
HI 96701 Free Chlorine HI 96762 Free Chlorine: low range HI 96711 Free and Total Chlorine
Designed for precision
• Easy access cuvette designed to deliver best results •
Single parameter photometers
Water
Water
HI 96701 Free Chlorine HI 96762 Free Chlorine: low range HI 96711 Free and Total Chlorine
photometry • photometry
41
photometry • photometry
Multiparameter photometer
h c n
be
44 Parameters with ONE meter The HI 83200 is one of the most versatile photometers measuring up to 44 of the most important water quality parameters.
To support operators through the analysis process without frequent recourse to the instruction manual, the instrument also benefits from a powerful interactive user support. Full tutorial is available in the Set up Menu while the Help menu provides assistance at every step during measurement.
Direct readout given in mg/L of parameter measured
PC connection via USB facilitates detailed recording of data
Hanna offers a wide range of reagents to be used with our instruments to ensure optimum results and working performance.
• Sample cuvettes and caps
For details of the reagent required for each parameter, see the measuring table below.
• Bottle for DO analysis • Power adapter
Step by step support
• Instructions
For order codes see over page.
1: Setup options include backlight, contrast, date, time
Test
Range
Test
Range
Aluminum
0.00 to 1.00 mg/L
Magnesium
0 to 150 mg/L
Alkalinity
0 to 500 mg/L
Manganese HR
0.0 to 20.0 mg/L
Ammonia MR
0.00 to 10.00 mg/L
Manganese LR
0 to 300 μg/L
Ammonia LR
0.00 to 3.00 mg/L
Molybdenum
0.0 to 40.0 mg/L
Bromine
0.00 to 8.00 mg/L
Nickel HR
0.00 to 7.00 g/L
Calcium
0 to 400 mg/L
Nickel LR
0.000 to 1.000 mg/L
Chlorine Dioxide
0.00 to 2.00 mg/L
Nitrate
0.0 to 30.0 mg/L
Free Chlorine*
0.00 to 2.50 mg/L
Nitrite HR
0 to 150 mg/L
Total Chlorine*
0.00 to 3.50 mg/L
Nitrite LR
0.00 to 0.35 mg/L
Chromium VI HR
0 to 1000 μg/L
Dissolved Oxygen
0.0 to 10.0 mg/L
Chromium VI LR
0 to 300 μg/L
Ozone
0.00 to 2.00 mg/L
Colour
0 to 500 PCU
pH
6.5 to 8.5 pH
Copper HR
0.00 to 5.00 mg/L
Phosphate HR
0.0 to 30.0 mg/L
Copper LR
0 to 1000 μg/L
Phosphate LR
0.00 to 2.50 mg/L
Cyanuric Acid
0 to 80 mg/L
Phosphorus
0.0 to 15.0 mg/L
Fluoride
0.00 to 2.00 mg/L
Potassium HR
20 to 200 mg/L
Hardness (calcium)
0.00 to 2.70 mg/L
Potassium MR
10 to 100 mg/L
Hardness (magnesium)
0.00 to 2.00 mg/L
Potassium LR
0.0 to 20.0 mg/L
Hydrazine
0 to 400 μg/L
Silica
0.00 to 2.00 mg/L
Iodine
0.0 to 12.5 mg/L
Silver
0.000 to 1.000 mg/L
Iron HR
0.00 to 5.00 mg/L
Sulfate
0 to 150 mg/L
Iron LR
0 to 400 μg/L
Zinc
0.00 to 3.00 mg/L
Specifications Wide based bench casing with angled keyboard for ease of use
Logging facility stores up to 200 readings
Mains and battery options allow for use on the benchtop or in spaces with restricted access to power
Helping you care clean and maintain your instruments
Product Code
HI-83200
Light Life
Life of the instrument
Light Detector
Silicon Photocell
Environment
0 to 50°C ; max 90% RH non-condensing
Power Supply
external 12 Vdc power adapter built-in rechargeable battery
Dimensions
235 x 200 x 110 mm
Weight
640 g
2: HELP key offers clear support on-screen
3: Select the parameter to be measured using the RANGE key
4: Tutorial function displays short guides to current operations
5: Press LOG key to save readings into memory
6: Press RCL key to recall logged information to the display
Choose from our wide range of accessories and solutions
photometry
photometry
Supplied with
Measures
Backlit LCD display improves clarity of readings
42
part no: HI 83200-02
Reagents
Complete with a facility to log and transfer data to a PC via USB, this meter is designed for use in applications where high precision and detailed records are integral to the development and maintenance of optimum water quality.
ideal for aquaculture and fish farming
Multiparameter photometer
Water
Water
part no: HI 83200-02
photometry • photometry
43
photometry • photometry
Reagents photometry
With the exception of the chlorine reagent which is supplied as an additive, all the other reagents listed here are supplied pre-dispensed in glass cuvettes ready for the sample to be added.
Range
Method
Ammonia high range
0 to 100 mg/L
Nessler
25
HI 93764B-25
Ammonia low range
0.00 to 3.00 mg/L
Nessler
25
HI 93764A-25
Chlorine (free)
0.00 to 5.00 mg/L
DPD
100
HI 93701-01
Chlorine (total)
0.00 to 5.00 mg/L
DPD
100
HI 93711-01
Nitrate
0.0 to 30.0 mg/L
Chromotropic acid
50
HI 93766-50
0.0 to 25.0 mg/L
Chromotropic acid
Nitrogen (total) high range
10 to 150 mg/L
Chromotropic acid
50
HI 93767B-50
Phosphorous
0.00 to 5.00 mg/L
Ascorbic acid
50
HI 93758B-50
Phosphorous (reactive)
0.00 to 5.00mg/L
Ascorbic acid
50
HI 93758A-50
Phosphorous (reactive high range)
0.00 to 100.0 mg/L
Vanadomolybdophosphoric acid
50
HI 93763A-50
Phosphorous (total)
0.00 to 3.50 mg/L
Ascorbic acid
50
HI 93758C-50
0.00 to 100.0 mg/L
Vanadomolybdophosphoric acid
50
HI 93763B-50
Nitrogen (total)
50
HI 93767A-50
Reagents for pocket checker testers Test
Range
No of tests
Order code
Alkalinity
0 to 300 ppm
25
HI 755-26
Chlorine (free)
0.00 to 2.50 ppm
25
HI 701-25
Chlorine (total)
0.00 to 2.50 ppm
25
HI 711-25
Nitrite
0 to 200 ppb
25
HI 764-25
Phosphate
0.00 to 2.50 ppm
25
HI 713-25
Phosphorous
0 to 200 ppb
25
HI 736-25
Reagents for HI 967series portable photometers
Test
Range
No of tests
Order code
Aluminum
0.00 to 1.00 mg/L
100
HI 93755-01
Alkalinity
0 to 500 mg/L
100
HI 93712-01
Ammonia LR
0.00 to 3.00 mg/L
100
HI 93700-01
Ammonia MR
0.00 to 10.00 mg/L
100
HI 93715-01
Bromine
0.00 to 8.00 mg/L
100
HI 93716-01
Calcium
0 to 400 mg/L
50
HI 937521-01
Chlorine Dioxide
0.00 to 2.00 mg/L
100
HI 93738-01
Free Chlorine
0.00 to 2.50 mg/L
100
HI 93701-01
Total Chlorine
0.00 to 3.50 mg/L
100
HI 93711-01
Chromium VI LR
0 to 300 μg/L
100
HI 93749-01
Chromium VI HR
0 to 1000 μg/L
100
HI 93723-01
Copper LR
0 to 1000 μg/L
100
HI 95747-01
Copper HR
0.00 to 5.00 mg/L
100
HI 93702-01
Cyanuric Acid
0 to 80 mg/L
100
HI 93722-01
Fluoride
0.00 to 2.00 mg/L
100
HI 93729-01
Hardness (calcium)
0.00 to 2.70 mg/L
100
HI 93720-01
Hardness (magnesium)
0.00 to 2.00 mg/L
100
HI 93719-01
Hydrazine
0 to 400 μg/L
100
HI 93704-01
Iodine
0.0 to 12.5 mg/L
100
HI 93718-01
Iron LR
0 to 400 μg/L
50
HI 93746-01
Iron HR
0.00 to 5.00 mg/L
100
HI 93721-01
Magnesium
0 to 150 mg/L
50
HI 937520-01
Manganese LR
0 to 300 μg/L
50
HI 93748-01
Manganese HR
0.0 to 20.0 mg/L
100
HI 93709-01
Molybdenum
0.0 to 40.0 mg/L
100
HI 93730-01
Nickel LR
0.000 to 1.000 mg/L
50
HI 93740-01
Nickel HR
0.00 to 7.00 g/L
100
HI 93726-01
Nitrate
0.0 to 30.0 mg/L
100
HI 93728-01
Nitrite LR
0.00 to 0.35 mg/L
100
HI 93707-01
Nitrite HR
0 to 150 mg/L
100
HI 93708-01
Dissolved Oxygen
0.0 to 10.0 mg/L
100
HI 93732-01
Ozone
0.00 to 2.00 mg/L
100
HI 93757-01
pH
6.5 to 8.5 pH
100
HI 93710-01
Phosphate HR
0.0 to 30.0 mg/L
100
HI 93717-01
Phosphate LR
0.00 to 2.50 mg/L
100
HI 93713-01
Phosphorus
0.0 to 15.0 mg/L
100
HI 93706-01
Potassium LR
0.0 to 20.0 mg/L
100
HI 93750-01
Potassium MR
10 to 100 mg/L
100
HI 93750-01
Test
Range
No of tests
Order code
Potassium HR
20 to 200 mg/L
100
HI 93750-01
Dissolved Oxygen
0 to 10m/L
100
HI 93732-01
Silica
0.00 to 2.00 mg/L
100
HI 93705-01
Chlorine (free)
0.00 to 5.00 mg/L
100
HI 93701-01
Silver
0.000 to 1.000 mg/L
50
HI 93737-01
Chlorine (free, low range) 0.000 to .0500 mg/L
100
HI 93762-01
Sulfate
0 to 150 mg/L
100
HI 93751-01
Chlorine (free and total)
100
HI 93711-01
Zinc
0.00 to 3.00 mg/L
100
HI 93731-01
www.hannanorden.com
0.00 to 5.00 mg/L
info@hannanorden.com
+46 300 404018
www.hannanorden.com
info@hannanorden.com
photometry
photometry
Phosphorous (total high range)
44
Order code
Reagents for HI 83200 multiparameter bench photometer
Test
No of tests
Reagents photometry
Water
Water
Reagents for HI 83214 COD and bench photometer
photometry • photometry
+46 300 404018
45
temperature • temperature
Pocket thermometers checktemps
Checktemp
Check out HANNA
Checktemps
Checktemp offers high accuracy over a wide range without the need to worry about breakage or condensation.
• High accuracy
A compact meter with a direct probe, it is ideal for taking quick-fire temperature measurement in semi-solids and liquids.
• Calibration feature
•
• Pocket dimensions
Easy read digital display – whatever the viewing angle
•
Simple to use with direct probe
100% reassurance with Hanna Cal Check With the Hanna Cal Check you can verify the accuracy of your meter in seconds – each and every time it is used.
• Simple to use
Pocket Thermometers
Supplied with
Water
Water Checktemp Range
temperature
Penetration probe and protective cap Battery and instructions
Hanna Checktemps are some of our best selling pocket thermometers. Each model in the range is small, compact and comes complete with the unique Hanna Cal Check to confirm the accuracy of your measurements – time after time. All models are supplied complete with probe, battery and full operating instructions.
Quick accurate temperature measurement Checktemp1
Checktemp 1 is a high accuracy thermometer with a 1m flexible cable for easy access in hard-to-reach locations. The sharp-tip stainless steel probe is designed to penetrate semi-solid products as well as taking measurements in liquids, air and frozen materials. Using an NTC thermistor sensor to deliver high levels of accuracy with speed and efficiency, Checktemp 1 is ideal for routine controls and quick sampling.
Activated by a simple switch, the Cal Check simulates an ice bath of 0.0˚C giving a confirmed base reading from which to test. With a tolerance limit of +/- 0.4˚C, you can be completely confident that your measurements are accurate.
Supplied with Penetration probe and cable (integral to meter) All models are supplied complete with probe, battery and full operating instructions.
46
Checktemp Dip
Product Code
Checktemp (HI 98501)
Checktemp1 (HI 98509)
Checktemp Dip (HI 98509-01)
Range
-50.0 to 150.0°C
-50.0 to 150.0°C
-20 to 100°C
Resolution
0.1°C
0.1°C
0.1°C
±0.3°C (-20 to 90°C) ±0.5°C
±0.3°C (-20 to 90°C) ±0.5°C
±0.3°C (-20 to 90°C) ±0.5°C
(outside)
(outside)
(outside)
Fixed stainless steel 105 x
stainless steel probe with 1
weighted probe with flexible
dia 3 mm
m cable
3m cable
1 x 1.5V
1 x 1.5V AAA
1 x 1.5V AAA
approx. 3000 hours of
approx. 3000 hours of
approx. 3000 hours of
continuous use
continuous use
continuous use
0 to 50°C ; RH max 95%
0 to 50°C ; RH max 95%
0 to 50°C ; RH max 95%
106 x 58 x 19 mm
106 x 58 x 19 mm
Accuracy
Probe Battery Type Battery Life Environment Dimensions Weight
66 x 50 x 25 mm - meter only 50 g
80 g
80 g
Checktemp Dip is a highly accurate thermometer with a wide temperature range of -20˚C to +100˚C.
Main benefits •
100% accurate, whatever the viewing angle
•
Ideal for spot checks
•
Instant measurement
•
Small, lightweight, easy to clean
www.hannaplus.com for latest and more complex products
The stainless steel probe is weighted and attached to a flexible 3m cable, making it ideal for dipping into any vat or tank to measure the temperature at different depths. Supplied with Weighted probe and 3m cable Battery and instructions
Call: +46 300 404018 or email: info@hannanorden.com
temperature
temperature
Specifications
Battery and instructions
47
temperature • temperature
Plug and play datalogging
Range of LCD display equipped dataloggers recording up to 16,000 measurements
One small meter ...
Tamper proof data collection
1
Full set of information and readings constantly on display
Store min/max temperature between logging intervals
Store up to 16,000 temperature samples in protected nonvolatile EEPROM memory
3 4
The quick plug and play feature combined with continuous temperature readout opens up huge possibilities for this series of meters.
Select log interval: from 1 second to 1 per 24 hours
Operators can take a variety of checks in different locations and in quick succession by simply switching probes. Designed to support best budgetary practice, one meter can be used with several different probes. This allows the instrument to be used for varying applications by simply exchanging the probe and selecting an appropriate alternative.
six BIG benefits
2 White, waterproof casing is easy to clean
5 6
Use with any Hanna Lumberg probe – no need to buy additional ones Test for calibration with certified Hanna test plugs Use as a hand-held thermometer with a standard hand-held probe for on the spot checks Fit a speciality probe for remote monitoring Operate with bespoke probes to suit specific applications Choice of 2 models: • 1 external sensor •
Logging delay - up to 199 hours in advance
High and low alarm points Use as a thermometer
Temp range: -40℃ to +125℃
Tamper proof data collection system with details stored in serial numbered lots
HI 141000 windows application software HI 141001 infrared transmitter
Test on the spot By using a certified Hanna calibration test plug, the datalogger can be checked for accuracy in a matter of moments – a boon for operators and companies alike. •
Simply plug in the calibration test plug in place of a probe
•
See the desired value on the LCD display
Supplied with
•
Save time and money with on the spot calibration which avoids the need to return the meter to the calibration laboratory
•
3.6v lithium AA battery
•
Magnetic key
•
Instructions
See p ag for a e 5 0 c of te hoice m probe perature s
Specifications Product Code Sensor(s) Range
Number of samples taken
Countdown to start of logging
Number of samples which have exceeded High/Low alarms
Min/Max temperature values
High and Low alarm points
Latest details on top selling lines and popular products online
HI 141GH/LUM
1 External
1 Internal 1 External
-40.0 to +125.0℃
-20.0 to +70.0℃ -40.0 to +125.0℃
Resolution
0.1°C / 0.1°F
Accuracy
+/-0.5°C (-40.0 to 0.0 and 70.0 to 100.0°C); +/-0.4°C (0.0 to 70.0°C); +/-1.0°C (>100.0°C)
Environment Dimensions Weight
www.hannanorden.com
HI 141DH/LUM
RH 100% 86.5mm diameter x 35mm height 150 grams
www.hannanorden.com
temperature
temperature
Available as optional extra
1 internal & 1 external sensor
Dual level LCD with capacity to display the following information
48
HI 141 series
Now featuring a new interchangeable Lumberg plug probe, the HI 141 series of Hanna dataloggers is more flexible than ever.
Plug and play
Plug and play datalogging
Water
Water
HI 141 series
temperature • temperature
49
temperature • temperature
Probes and accessories HI 141 series
Hanna dataloggers help maintain a rigorous temperature monitoring schedule
Probes for the HI 141 dataloggers are supplied complete with handle and 1m cable and Lumberg plug unless otherwise stated.
Mini temperature datalogger HI 143
Low cost, miniature discreet This great little meter offers a fantastic low cost solution for use across a wide range of applications. It has an extensive memory capacity, excellent security measures and is still small enough to be easily hidden.
Probes
Ideal for
Air
Liquids
HI 762A/LUM
HI 762L/LUM
Fast response check for changes in air temperatures
Designed for liquid testing
Dimensions:
probe stem: 100mm diam: : 3mm
probe stem: 100mm diam: : 3mm
Dimensions:
General purpose
HI 762PW/LUM General purpose penetration probe
Dimensions: probe stem: 100mm diam: : 3mm
Air
Air
HI 762W/LUM
HI 762WT/LUM
Flexible air wire without handle
PTFE insulated flexible air wire without handle
Wire dimensions: length: 1m diam: 3mm
Wire dimensions: length: 1m diam: 3mm
Accessories
Wall cradle and padlock included
Programmable high and low alarm points
Clear LCD display with choice of ℃ or ℉ reading
Water
Water
High accuracy thermistor probes: use with HI 141 dataloggers
temperature • temperature
•
Discreet temperature monitoring
•
Temperature sensitive transport
•
Laboratory fridges
•
Water samples
USB connection for download and analysis of results
Main Benefits •
Store up to 4000 temperature samples
•
Password protection to prevent unauthorised tampering
•
IP65 water and dust protection
•
Two-year continuous use battery
50
Supplied with
0°C calibration test plug
HI 762-00CC/LUM Check calibration of data logger at 0°C
Minus 18°C calibration test plug
HI 762-18CC/LUM Check calibration of data logger at -18°C
Like photography...
Plus 70°C calibration test plug
HI 762-70CC/LUM Check calibration of data logger at + 70°C
send in photos…
vote for your favourites…
Product Code
HI 143
Range
-30.0 to +70.0ºC
Resolution
0.1°C / 0.1°F
Accuracy
±0.4°C (-20 to +60°C); ±0.6°C (outside)
Typical EMC Dev.
±0.3°C / ±0.5°F
Calibration
Factory calibrated Up to 4000 samples
•
CR2302 lithium battery
•
Wall cradle and padlock
Data Logging
•
USB connector
Logging Interval
User selectable, from 1 minute to 24 hours
•
Instructions
Battery Type
1 x CR2032 3V lithium battery
Battery Life
2 years
Protection
IP 65 (watertight)
Dimensions
60 x 37 x 17 mm
www.hannacalendar.com visit our website www.hannacalendar.com
temperature
temperature
Specifications
51
temperature • temperature
High accuracy handheld thermometer
Maintenance and awareness are the first lines of defence in the battle against legionella.
part no: HI 935005/KIT
Legionella temperature test kit
Supporting operators in this battle, the Hanna HI 935005 delivers highly accurate temperature measurements across a wide range using a K-type thermocouple probe.
• Waterproof casing • Large LCD display gives clear readings for current temperature plus min and max temp values since startup
Used to test pipe surface or water temperatures, the HI 935005 is well-placed to head off Legionella concerns for a wide variety of industrial and leisure industries.
• Rubberised buttons are clearly marked for ease of use
Complies with Health and Safety Regulations to meet stringent quality standards
•
Easy shift between °C and °F
•
HOLD to freeze readings on display and give more time to record data
•
Used regularly in applications where warm or hot water is converted into droplet or steam formation, the high accuracy HI 935005 can help to prevent the risk of Legionella by ensuring that temperatures are high enough in the water system to destroy the bacteria.
•
Provides everything needed to run a full temperature maintenance schedule. Options available
•
Water temperature from sentinel taps
liquid and surface probes, rubber boot, calibration certificate, batteries and instructions
Ideal for
HI 935005/KIT
•
Hospitals
Range
-50 to +199.9°C and +200 to +1350°C
•
Schools and colleges
Resolution
0.1°C up to 199.9°C and 1‡C above that
•
Accuracy
0.1% of full range
Residencial and care homes
Battery Type
3 x AA batteries
Dimensions
150 x 80 x 26mm
•
Weight
235g
Civic centres and leasure centres
•
Swimming pools and aquariums
•
Cooling towers
HI 935005KIT
Pipe surface temperatures
Full kit:
1 x SCK1 surface probe 100 x 4.7mm with 1m cable
Ready to go kit:
•
batteries and instructions
Equipped with Battery Error Prevention System to alert user if low battery is likely to adversely affect readings
1 x LPK1 liquid probe 100 x 3.2mm with 1m cable,
Air and water handling systems
Meter only:
Product Code
Probes
•
Supplied with
CLEAR button restarts evaluation of high and low values
Specifications
Need s probe pare s? Q
uote part n umbe LDK 1 rs: f on 1 m or liquid probe cable SCK1 f on 1 m or surfac e pro cable be
Fact
Meter only: HI 935005
temperature
Proactive management of water systems provides best protection against the spread of legionella bacteria.
temperature
52
Product uses
Legionella bacteria are spread by water droplet contamination. It is therefore virtually impossible to guarantee that the bacteria will not exist in a water system. But by adopting a rigorous, proactive approach with routine controls, the risk of an outbreak can be minimised.
www.hannanorden.com
Display showing minimum and maximum temperature values taken during the measuring session helps with comprehensive record taking.
High accuracy handheld thermometer
Water
Water
part no: HI 935005/KIT
temperature • temperature
info@hannanorden.com
+46 300 404018
www.hannanorden.com
info@hannanorden.com
+46 300 404018
53
turbidity • turbidity • turbidity
Portable turbidity meter
This microprocessor based turbidity meter delivers laboratory grade accuracy for field or factory use.
Turbidity, chlorine, pH, Br, Fe, I & CYS
High accuracy turbidity for field or factory
Rivers and canals
•
Waste water
•
Bore holes and wells
Delivering laboratory grade accuracy, this all in one instrument allows operators to measure turbidity, pH, total and free chlorine, bromine, iodine, iron and cyanuric acid quickly and easily.
Clear LCD gives readings across all parameters
Robust waterproof casing
Designed for rigorous testing conditions where speed and precision are of utmost importance, it is the ideal meter for measuring drinking water and similar high definition applications.
Rubberised keyboard with responsive buttons
Calibration options allow users to either select the factory pre-programmed setting or choose their own
Supplied with HI 93703 meter only:
Main benefits
glass cuvette, batteries and instructions
Specifications
Full kit: HI 93703, glass cuvettes, starter pack of solutions, lint free tissues, batteries, carry case and instructions
Solutions and accessories
• • •
See page 57 for details
•
Range: 0.00 to 1000 FTU
Product Code
Range
Waterproof, dust resistant casing Rubberised keyboard is clearly marked for ease of use Wide range (0.00 to 1000 FTU) promotes usability in wide variety of applications from drinking water to waste water Easy three-point calibration
Resolution
•
Fully recessed LCD display
Specifications
The HI 93703 is available as a full ‘ready to go maintenance kit’ complete with a starter pack of calibration and cleaning solutions, lint free tissues, measurement cuvettes and rugged carrying case. To order quote: HI 93703C
HI 93102
Turbidity
0.00 to 9.99 NTU / 0.00 to 50.0 NTU
Bromine
0.00 to 8.00 mg/L (ppm)
Free Chlorine
0.00 to 2.50 mg/L (ppm)
Total Chlorine
0.00 to 3.50 mg/L (ppm)
CYS
0 to 80 mg/L (ppm)
Iodine
0.0 to 12.5 mg/L (ppm)
Iron LR
0.00 to 1.00 mg/L (ppm)
pH
6.5 to 8.5 pH
Turbidity
0.01 and 0.1 NTU
Bromine
0.01 mg/L (ppm)
Chlorine
0.01 mg/L (ppm)
CYS
1 mg/L (ppm)
Iodine
0.1 mg/L (ppm)
Iron LR
0.01 mg/L (ppm)
pH
0.1 pH
Turbidity
±0.5 NTU or ±5% of reading (whichever is greater)
Reagents, standards and accessorie s on page 5 7
Product Code
HI 93703
Bromine
±0.08 mg/L (ppm) ±3% of reading
Range
0.00 to 50.00 FTU; 50 to 1000 FTU
Chlorine
±0.03 mg/L (ppm) ±3% of reading
Resolution
0.01 FTU (0.00 to 50.00 FTU); 1 FTU (50 to 1000 FTU)
CYS
±1 mg/L (ppm) ±15% of reading
Accuracy
±0.5 FTU or ±5% of reading (whichever is greater)
Iodine
±0.1 mg/L (ppm) ±5% of reading
Light Source
Infrared LED
Iron LR
±0.02 mg/L (ppm) ±8% of reading
Light Detector
Silicon photocell
pH
±0.1 pH
Auto Off
After 5 minutes of non-use
Calibration
two points; selectable between 0.00 - 50.0 FTU (0.00 and 20.0 FTU recommended)
Calibration
3 points (0 FTU, 10 FTU and 500 FTU)
Light Source
pure green LED
Power Supply
4 x 1.5V AA batteries / approx 60 hours of continuous use or 900 measurements
Light Detector
silicon photocell
Battery Type / Life
1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes
Accuracy @25℃
Environment
0 to 50°C ; RH max 95% non-condensing
Dimensions
220 x 82 x 66 mm
Environment
0 to 50°C ; RH max 95% (non condensing)
Weight
510 g
Dimensions / Weight
220 x 82 x 66 mm / 510 g
Hanna is a global brand renowned for high precision and great value
•
Sophisticated microprocessor ensures measurements are delivered with speed, precision and repeatability
•
Capacity to log and retrieve up to 25 different samples including time and date of measurement
•
Advanced electronics allow operators to calibrate the meter at a selectable point in from 0.00 to 50.00 NTU or to select factory pre-programmed setting
•
Use of high end technology delivers optimum accuracy and quality of results in a portable hand-held unit that weighs little more than 500 grams
Supplied with •
Measurement cuvette and cap
•
Batteries
•
Instructions
Our products are competitive, innovative and popular
turbidity
turbidity
Full Maintenance Kit
54
•
part no: HI 93102
The most important parameters needed for water analysis can all be measured by using just one meter – the Hanna HI 93102.
Log and retrieve up to 25 different samples
Ideal for Drinking water
Complete tool for water analysis Measurement cuvette and cap supplied as standard – spares available as optional
Waterproof, easy to hold and with a simple threepoint calibration process, it is ideal for water testing and has proved highly popular across the UK.
•
Full water analysis
Water
Water
part no: HI 93703
turbidity • turbidity • turbidity
55
ISO bench turbidity meter with datalogging
turbidity • turbidity • turbidity
part no: HI 88713
ISO low range turbidity
turbidity • turbidity • turbidity
Reagents, standards and accessories turbidity
Accessories
– ideal for water quality testing
Water
Access on-screen support via HELP key
Graphic backlit LCD display
Four turbidity measurement modes
er To ord
ds and Standar . ns solutio e See pag e opposit
Wide bench top format with easy clean casing and user-friendly interface
Step by step guide through the analysis process
pack of 4 glass cuvettes
Hanna Turbidity Standards To check the calibration of your turbidity meter, Hanna offers AMCO AEPA-1 standards in ready to use 30ml bottles. Our turbidity calibration solutions are referenced to the AMCO AEPA-1 standards at 0, 10 and 500 FTU and 0 and 20 NTU. Unlike formazine based standards, they are stable, long lasting and - most importantly - NOT toxic.
Range of calibration options •
Perform 2,3,4 or 5 point calibration using Hanna standards
•
Calibration points can be modified when user prepared standards are used
•
Complete Good Laboratory Practice (GLP) functions allow traceability of the calibration conditions
Range
•
Calibration at 2,3,4 or 5 points
•
Choice of four turbidity measurement modes
Accuracy
Choice of 3 measuring modes - select between normal, continuous or signal averaging measurement User-friendly display with guidance codes
•
Log up to 200 samples
•
Data transfer to PC available as optional using USB cable and HI 92000 Windows compatible software
HI 88713 FNU Mode
0.00 to 9.99; 10.0 to 99.9; 100 to 1000 FNU
FAU Mode
10.0 to 99.9; 100 to 4000 FAU
NTU Ratio Mode
0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
NTU Non-Ration Mode
0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 245 EBC
FNU Mode
0.01; 0.1; 1 FNU
FAU Mode
0.1; 1 FAU
NTU Ratio Mode
0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
NTU Non-Ration Mode
0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
FNU Mode
±2% of reading plus straylight
FAU Mode
±10% of reading
NTU Ratio Mode
±2% of reading plus straylight / ±5% of reading above 1000 NTU
NTU Non-Ration Mode
±2% of reading plus straylight
Repeatability
±1% of reading or straylight, whichever is greater
Stray Light
< 0.1 NTU (0.05 EBC)
Light Detector
Silicon Photocell
Light Source / Lamp life
IR LED / Instrument life
Method
ISO 7027 Method
Measuring Mode
Normal, Average, Continuous.
Turbidity Standards
<0.1, 15, 100, 750 FNU and 2000 NTU
Calibration
Two, three, four or five-point calibration
LOG Memory / Serial Interface
200 records / USB
Environment
0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply
12 Vdc power input
Dimensions / Weight
230 x 200 x 145 mm / 2.5 Kg
Helping you care clean and maintain your instruments
HI 93703-0
HI 93703-10
HI 93703-05
HI 93102-0
HI 93102-20
30ml bottle of ready to use AMCO AEPA-1 calibration standard solution at 0 FTU
30ml bottle of ready to use AMCO AEPA-1 calibration standard solution at 10 FTU
30ml bottle of ready to use AMCO AEPA-1 calibration standard solution at 500 FTU
30ml bottle of ready to use AMCO AEPA-1 calibration standard solution at 0 NTU
30ml bottle of ready to use AMCO AEPA-1 calibration standard solution at 20 NTU
Reagents: for use with HI 93102 To measure turbidity with the HI 93102 meter there is no need to purchase any additional reagents. If you wish to measure one or more of the other parameters the meter measures, simply select the appropriate reagent for your test from the list below.
HI 93701-01 HI 93710-01 HI 93711-01 HI 93716-01 HI 93718-01 HI 93722-01 HI 93746-01
reagent kit for 100 tests of Chlorine(Free) reagent kit for 100 tests of pH reagent kit for 100 tests of Chlorine(total) reagent kit for 100 tests of Bromine reagent kit for 100 tests of Iodine reagent kit for 100 tests of Cyanuric Acid reagent kit for 100 tests of Iron
Choose from our wide range of accessories and solutions
turbidity
turbidity
•
Product Code
Main Benefits
•
Clear tutorial messaging
HI 731321
Specifications
Resolution
•
•
pack of 4 lint free specialist cleaning cloths for cuvettes
Store up to 200 measurements in internal memory via LOG key
56
HI 731318
Using an infra-red light source it guarantees measurement repeatability and consistency. Variations in the intensity of the LED are also compensated for – limiting the need for frequent calibration.
Water
The HI 88713 is a high accuracy bench top turbidity meter designed to meet and exceed the requirements of ISO 7027 standard.
57
Temperature Calibration why, what and how A
ll temperature measurement meters require regular calibration and checking to ensure they deliver the high levels of accuracy demanded by health and safety legislation in the UK and EU. Although there is no specified frequency for calibration it is general practice is to carry out an annual calibration and re-certification on the thermometers used in the workplace.
An annual check by a certified calibration laboratory will ensure the readings taken with a digital thermometer can be relied upon. What many people do not realise is that there is a difference in quality between different types of accreditation and the certificates issued.
Hanna Temperature Calibration Lab
F
or ultimate reassurance, the Hanna Temperature Calibration Lab is fully UKAS accredited and runs a comprehensive facility to test, check and calibrate all makes of digital thermometers and sensors to international standards.
Contact us for details on our service and calibration packages. T: 01525 850 855 E: sales@hannainst.co.uk
Did you know ? If your thermometer and sensor have a UKAS certificate, they can be used as a Reference Thermometer to check the accuracy of other thermometers. This is ideal for a company or organisation where multiple thermometers need to be checked.
UKAS calibration certificates
58
123456 123
•
Only a UKAS accredited laboratory can issue a UKAS calibration certificate
•
All equipment used is fully UKAS accredited
•
All monitoring systems adhere to the highest possible standards in the UK and the EU
•
All UKAS calibration laboratories are subjected to a rigorous annual inspection by the United Kingdom Accredited Service (UKAS) to ensure that all technicians, equipment and systems consistently meet the most precise requirements
•
Only laboratories with full accreditation are permitted to carry the UKAS logo on certificates
service and calibration
service and calibration
At the pinnacle, UKAS accredited calibration offers complete assurance that the checking procedure is as accurate as is physically possible.
0000
12345678A
123456
Calibration certificates traceable to UKAS Traceable to UKAS means that only the measurement equipment used to check calibration has itself been UKAS tested. It does not confirm that the procedures or the laboratory meet UKAS standards.
For temperature calibration, contact our Hanna calibration lab
Call: +46 300 404018 or email: info@hannanorden.com
59
Index
warranty and returns policy Every Hanna product has been designed and manufactured in a wholly-owned Hanna production plant to ensure you receive the best in test and measurement instrumentation and product.
The warranty period applies from the date of purchase by the first customer and is not transferable •
All instruments are supplied with a 12 month warranty which can be upgraded to a 2 year warranty for an additional charge
•
Sensors, electrodes and pocket meters such as the pocket Checker photometer series, pH and conductivity testers are supplied with a 6 month warranty
The warranty covers manufacturing defects only •
This does not include consumable items such as batteries, bulbs, and ink cartridges unless listed
•
The liability of Hanna Instruments is limited to the cost of repair and/or replacement of the product under warranty
The warranty is invalidated •
If the defect is caused (howsoever) by misuse, neglect, and tampering or incorrect adjustment
•
If unauthorised persons carry out any alterations and/or repairs
The warranty is also invalidated in the following cases •
For repair due to incorrect installation
•
For repair to any product where the serial number has been removed
•
Where any ancillary equipment not furnished or recommended by Hanna Instruments causes problems or damage that is attached to or used in connection with the product
Warranty support Hanna Instruments Ltd support a product purchased in the United Kingdom, Ireland and Scandinavian countries listed here: Denmark, Finland, Iceland, Norway, Sweden.
warranty
If the product is purchased in another part of the globe then Hanna Instruments Ltd may attempt a repair. Hanna Instruments Ltd cannot guarantee the outcome.
60
Repairs under warranty To obtain technical assistance or to book a service/repair to your product under warranty, please contact our customer care centre. To assist our customer service team, please have your model number, serial number and date of purchase ready when calling.
www.hannanorden.com
info@hannanorden.com
+46 300 404018
Index Products are indexed by part number and by parameter for ease of reference. • Part numbers are listed numerically • Products are listed alphabetically by parameter and then in order of format – pocket, portable, bench
61
part number • part number • part number
Index of products Products are indexed by part number and by parameter for ease of reference.
62
• Products are listed alphabetically by parameter and then in order of format – pocket, portable, bench
Description
Page
Part No
Description
Page
HI 76309/1.5
Conductivity probe for use with HI 98360 meter
25
HI 764
Pocket photometer for Nitrite measurement
39
HI 76407/2
Dissolved oxygen probe for use with HI 2400 bench meter
27
HI 764-25
Set of 25 Nitrite reagents for HI 764 Nitrite checker
44
HI 7662
Temperature probe for use with HI 2215, PH20
35
HI 83200-02
Multiparameter bench top photometer
42
HI 83214
Waste water analysis bench meter
12
HI 839800
25 vial thermo-reactor for COD and other tube test reagents
15
HI 88713
Bench top ISO turbidity meter with datalogging function
56
HI 9033
Portable waterproof multi-range conductivity meter
22
HI 1288
Multiparameter probe with pH, conductivity and temperature
21
HI 9124
Portable pH meter - waterproof
34
HI 141DH/LUM
Plug and play datalogger - 1 sensor version
48
HI 9125
Portable pH and ORP/Redox meter - waterproof
34
HI 141GH/LUM
Plug and play datalogger - 2 sensor version
48
HI 9146-04
Portable dissolved oxygen meter
27
HI 143
Mini temperature datalogger
51
HI 92000
Windows compatible software for data analysis
12, 56
Portable water analysis meter
55
HI 70004P
25 x 20ml sachets - pH 4 buffer solution
36
HI 93102
HI 70006P
25 x 20ml sachets - pH 6 buffer solution
36
HI 93102-0
Turbidity standard - 30ml bottle of 0 NTU solution
57
HI 70007P
25 x 20ml sachets - pH 7 buffer solution
36
HI 93102-20
Turbidity standard - 30ml bottle of 20 NTU solution
57
HI 70010P
25 x 20ml sachets - pH 10 buffer solution
36
HI 935005
Portable K-type digital thermometer
53
HI 7004L
pH buffer solution - 500ml bottle of pH 4 solution
36
HI 935005/KIT
Legionella temperature test kit
52
HI 7006L
pH buffer solution - 500ml bottle of pH 6 solution
36
HI 93700-01
Set of 100 low range Ammonia reagents for HI 83200 meter
45
HI 7007L
pH buffer solution - 500ml bottle of pH 7 solution
36
HI 93701-01
Set of 100 Free Chlorine reagents for HI 83200 and HI 96701
13, 45, 57
Set of 100 Copper high range reagents for HI 83200
45
HI 7009L
pH buffer solution - 500ml bottle of pH 9 solution
36
HI 93702-01
HI 701
Pocket photometer for Free Chlorine measurement
39
HI 93703
Portable turbidity meter
54
HI 7010L
pH buffer solution - 500ml bottle of pH 10 solution
36
HI 93703-0
Turbidity standard - 30ml bottle of 0 FTU solution
57
HI 701-25
Set of 25 Free Chlorine reagents for HI 701 Chlorine checker
44
HI 93703-05
Turbidity standard - 30ml bottle of 500 FTU solution
57
HI 70300L
pH electrode storage solution - 500ml bottle
36
HI 93703-10
Turbidity standard - 30ml bottle of 10 FTU solution
57
Portable turbidity meter kit
54
HI 7061L
Cleaning solution - 500ml bottle general purpose solution
36
HI 93703C
HI 7073L
Cleaning solution - 500ml bottle protein cleaning solution
36
HI 93704-01
Set of 100 Hydrazine reagents for HI 83200
45
HI 7074L
Cleaning solution - 500ml bottle inorganics cleaning solution
36
HI 93705-01
Set of 100 Silica reagents for HI 83200
45
HI 7077L
Cleaning solution - 500ml bottle oils & fats cleaning solution
36
HI 93706-01
Set of 100 Phosphorus reagents for HI 83200
45
HI 711
Pocket photometer for Total Chlorine measurement
39
HI 93707-01
Set of 100 Nitrite low range reagents for HI 83200
45
HI 711-25
Set of 25 Total Chlorine reagents for HI 711 Chlorine checker
44
HI 93708-01
Set of 100 Nitrite high range reagents for HI 83200
45
HI 713
Pocket photometer for Phosphate measurement
39
HI 93709-01
Set of 100 Manganese high range reagents for HI 83200
45
Set of 100 pH reagents for HI 83200
45, 57
HI 713-25
Set of 25 Phosphate reagents for HI 713 checker
44
HI 93710-01
HI 73120
ORP/Redox electrode for use with HI 98120
29
HI 93711-01
Set of 100 Total Chlorine reagents for HI 83200 and HI 96711
13, 45, 57
HI 73127
pH electrode for use with HI 98121 & HI 98127, HI 98128
29, 33
HI 93712-01
Set of 100 Alkalinity reagents for HI 83200 meter
45
HI 73128
Electrode removal tool for use with pocket meters
29, 31, 33
HI 93713-01
Set of 100 Phosphate low range reagents for HI 83200
45
HI 731318
Lint free cuvette cleaning cloths - set of 4
57
HI 93715-01
Set of 100 medium range Ammonia reagents for HI 83200 meter
45
Set of 100 Bromine reagents for HI 83200 meter
57
HI 731321
Glass cuvettes - set of 4
57
HI 93716-01
HI 736
Pocket photometer for Phosphorus measurement
39
HI 93717-01
Set of 100 Phosphate high range reagents for HI 83200
45
HI 736-25
Set of 25 Phosphorous reagents for HI 736 Phosphorous checker
44
HI 93718-01
Set of 100 Iodine reagents for HI 83200
45, 57
HI 755
Pocket photometer for Alkalinity measurement
39
HI 93719-01
Set of 100 Magnesium hardness reagents for HI 83200
45
HI 755-26
Set of 25 Alkalinity reagents for HI 755 Alkalinity checker
44
HI 93720-01
Set of 100 Calcium hardness reagents for HI 83200
45
Set of 100 Iron high range reagents for HI 83200
45
HI 762A
Drilled tip fast response air probe - use with HI 93510
50
HI 93721-01
HI 762A/LUM
Drilled tip fast response air probe - Lumberg
50
HI 93722-01
Set of 100 Cyanuric acid reagents for HI 83200
45, 57
HI 762L
Liquid general purpose probe - use with HI 93510
50
HI 93723-01
Set of 100 Chromium VI high range reagents for HI 83200
45
HI 762PW
General purpose penetration probe - use with HI 93510
50
HI 93726-01
Set of 100 Nickel high range reagents for HI 83200
45
HI 762PW/LUM
General purpose food penetration probe - Lumberg
50
HI 93728-01
Set of 100 Nitrate reagents for HI 83200
45
HI 762W
Flexible wire probe - use with HI 93510
50
HI 93729-01
Set of 100 Fluoride reagents for HI 83200
45
HI 762W/LUM
Flexible wire probe - Lumberg
50
HI 93730-01
Set of 100 Molybdenum reagents for HI 83200
45
Set of 100 Zinc reagents for HI 83200
45
HI 762WT
Flexible high temperature probe - use with HI 93510
50
HI 93731-01
HI 76302W
Conductivity probe for use with HI 8733 & HI 9033
23
HI 93732-01
Dissolved oxygen reagent - 100 tests
44, 45
HI 76309
Conductivity probe for use with HI 9835 meter
25
HI 93737-01
Set of 50 Silver reagents for HI 83200
45
www.hannaplus.com for latest and more complex products
Call: +46 300 404018 or email: info@hannanorden.com
index
index
Part No
• Part numbers are listed numerically
part number • part number • part number
63
parameter • parameter • parameter
part number • part number • part number
64
Description
Page
HI 93738-01
Set of 100 Chlorine Dioxide reagents for HI 83200 meter
45
HI 93740-01
Set of 50 Nickel low range reagents for HI 83200
45
HI 93746-01
Set of 50 Iron low range reagents for HI 83200
45, 57
HI 93748-01
Set of 50 Manganese low range reagents for HI 83200
45
HI 93749-01
Set of 100 Chromium VI low range reagents for HI 83200
45
HI 93750-01
Set of 100 Potassium reagents for HI 83200
45
HI 93751-01
Set of 100 Sulfate reagents for HI 83200
45
HI 937520-01
Set of 50 Magnesium reagents for HI 83200
45
HI 937521-01
Set of 50 Calcium reagents for HI 83200 meter
45
HI 93754A-25
COD reagent - 25 tests (low range EPA Dichromate)
14
HI 93754B-25
COD reagent - 25 tests (medium range EPA Dichromate)
14
HI 93754C-25
COD reagent - 25 tests (high range Dichromate)
14
HI 93754D-25
COD reagent - 25 tests (low range Mercury free)
14
HI 93754E-25
COD reagent - 25 tests (medium range Mercury free)
14
HI 93754F-25
COD reagent - 25 tests (low range ISO Dichromate)
14
HI 93754G-25
COD reagent - 25 tests (medium range ISO Dichromate)
14
HI 93755-01
Set of 100 Aluminium reagents for HI 83200 meter
45
HI 93757-01
Set of 100 Ozone reagents for HI 83200
45
HI 93758A-50
Phosphorus reagent - 50 tests (reactive)
44
HI 93758B-50
Phosphorus reagent - 50 tests (Hydrolyzable acid)
44
HI 93758C-50
Phosphorus reagent - 50 tests (total)
44
HI 93763A-50
Phosphorus reagent - 50 tests (reactive high range)
44
HI 93763B-50
Phosphorus reagent - 50 tests (total high range)
13, 44
HI 93764A-25
Ammonia reagent - 25 tests (low range, Nessler method)
44
HI 93764B-25
Ammonia reagent - 25 tests (high range, Nessler method)
44
HI 93766-50
Nitrate reagent - 50 tests
44
HI 93767A-50
Nitrogen reagent - 50 tests (total)
44
HI 93767B-50
Nitrogen reagent - 50 tests (total high range)
44
HI 95747-01
Set of 100 Copper low range reagents for HI 83200
45
HI 96701
Photometer for Free Chlorine
41
HI 96711
Photometer for Free and Total Chlorine
41
HI 96732
Photometer for dissolved oxygen measurement
26
HI 96762
Photometer for low range Free Chlorine
41
HI 98120
Pocket ORP/Redox tester
28
HI 98121
Pocket ORP/Redox and pH tester
28
HI 98127
Pocket pH meter with 0.1pH resolution
30
HI 98128
Pocket pH meter with 0.01pH resolution
30
HI 98129
Pocket pH/TDS/conductivity low range tester
32
HI 98130
Pocket pH/TDS/conductivity high range tester
32
HI 98160
Portable waterproof pH and ORP meter with memory
37
HI 98311
Pocket conductivity tester - low range
19
HI 98312
Pocket conductivity tester - high range
19
HI 9835
Portable multi-range conductivity, TDS and NaCL meter
24
HI 98360
Portable waterproof multiparameter conductivity meter
24
To order Call: +46 300 404018 Email: info@hannanorden.com Visit: www.hannanorden.com
Parameter
Product
Part No
Page
Chemical Oxygen Demand
Waste water analysis bench meter
HI 83214
12
25 vial thermo-reactor for COD & test tube reagents
HI 839800
15
COD reagents
Conductivity
Dissolved Oxygen
ORP/Redox
14
Pocket conductivity tester with probe
PRIMO
17
Pocket conductivity tester with probe
PRIMO5
17
Pocket conductivity tester - low range
HI 98311
19
Pocket conductivity tester - high range
HI 98312
19
Portable pH/conductivity/TDS meter
HI 991300
20
Portable multi-range conductivity/TDS/pH meter
HI 991301
20
Portable waterproof multi-range conductivity meter
HI 9033
22
Portable multi-range conductivity/TDS/NaCl meter
HI 9835
24
Portable waterproof multiparameter conductivity meter
HI 98360
24
Photometer for dissolved oxygen
HI 96732
26
Portable dissolved oxygen meter
HI 9146-04
27
Pocket ORP/Redox tester
HI 98120
28
Pocket ORP/Redox & pH tester
HI 98121
28
HI 98501
Pocket thermometer - Checktemp
47
Pocket pH meter 0.1 pH resolution
HI 98127
30
HI 98509
Pocket thermometer - Checktemp1
47
Pocket pH meter 0.01 pH resolution
HI 98128
30
HI 98509-01
Pocket thermometer - Checktemp Dip
47
Pocket pH/TDS/conductivity meter - low range
HI 98129
32
HI 991300
Portable pH, conductivity and TDS meter
20
Pocket pH/TDS/conductivity meter - high range
HI 98130
32
HI 991301
Portable multi-range conductivity, TDS and pH meter
20
Portable pH meter - waterproof
HI 9124
34
PRIMO
Pocket conductivity tester complete with probe
17
Portable pH & ORP/Redox meter - waterproof
HI 9125
34
PRIMO5
Pocket conductivity tester complete with probe
17
Portable pH/conductivity/TDS meter
HI 991300
20
SCK1
Copper spring tipped surface probe - use with HI 93530
53
Portable waterproof pH/ORP meter with memory
HI 98160
37
pH
Solutions and accessories for pH measurement
Latest details on top selling lines and popular products online
www.hannanorden.com
index
index
Part No
36
www.hannanorden.com
65
parameter â&#x20AC;˘ parameter â&#x20AC;˘ parameter Parameter
Product
Part No
Page
Photometry
Pocket photometer for alkalinity
HI 755
39
Pocket photometer for free chlorine
HI 701
39
Pocket photometer for total chlorine
HI 711
39
Pocket photometer for nitrite
HI 764
39
Pocket photometer for phosphate
HI 713
39
Pocket photometer for phosphorus
HI 736
39
Photometer for free chlorine
HI 96701
41
Photometer for free chlorine - low range
HI 96762
41
Photometer for free and total chlorine
HI 96711
41
Photometer for dissolved oxygen
HI 96732
26
Multiparameter bench top photometer
HI 83200-02
42
Waste water analysis bench meter
HI 83214
12
Reagents for photometers Temperature
66
Checktemp
HI 98501
47
Checktemp 1
HI 98509
47
Checktemp Dip
HI 98509-01
47
Mini temperature datalogger
HI 143
51
Plug and play datalogger - 1 sensor version
HI 141DH/LUM
48
Plug and play datalogger - 2 sensor version
HI 141GH/LUM
48
Portable K-type digital thermometer
HI 935005
53
Legionella temperature test kit
HI 935005/KIT
52
Portable turbidity meter
HI 93703
54
Portable turbidity meter kit
HI 93703C
54
Portable water analysis meter
HI 93102
55
Bench top ISO turbidity meter with datalogging
HI 88713
56
Accessories for turbidity measurement
57
Reagents for turbidity measurement
57
www.hannanorden.com
a web site dedicated to Scandinavian countries
44
index
Turbidity
.com
info@hannanorden.com
+46 300 404018
To view the Hanna product range, or to place your order on-line in your local currency please check out our dedicated web site and on-line shop. Featuring the entire Hanna range of over 3,000 part numbers our site provides detailed information on each product including technical data sheets, instrument specifications and recommended accessories. Alternatively you may wish to discuss your application before making your purchase decision and we are always happy to hear from you and help. Simply call us on +46 300 404018 we look forward to being of service.
Three ways to do business with HANNA Visit www.hannanorden.com
Email info@hannanorden.com
Phone +46 300 404018
Hanna Instruments Lennart Kollberg Phone +46 300 404018 Fax +46 300 14122 Email lennart@hannanorden.com
HannaNorden AB Energigatan 15 B 434 37 KUNGSBACKA Sverige / Sweden