solar Front&Inside pagination revised:Layout 1
19/10/07
17:24
Page 1
Specification Tables Technical Data - Clearly Solar Flat Plate Collector Model
Flurosorb
Dimensions and weights Orientation
Portrait or Landscape
Height / Width / Depth (mm)
1930/1160/110
Overall collector area (mm)
2.24
Aperture area (m2)
2.02
Absorber area (m2)
2.02
Weight (empty) (kg)
43
Capacity (solar fluid) (l)
1.1
Clearly Solar Straightforward Solar Thermal Solution
Performance Solar glass transmission (%)
91
Solar radiation absorption (%)
95
Solar radiation emission (%)
5
Efficiency ηо (%)
81.8
Efficiency coefficient a1 (W/(m2•K))
3.47
Efficiency coefficient a2 (W/(m2•K))
0.0101
Max operating pressure (bar)
10
Shutdown temperature (˚C)
196
Stagnation temperature (˚C)
227
Certification
CE 0036 & Solar Keymark
Materials & construction Absorber plate
Copper
Absorber plate coating
Sunselect (selective)
Absorber tube
Copper
Absorber tube joints
Ultrasonically welded
Frame
Aluminium Extruded sides / sheet rear
Frame / glazing joint
EPDM
Glazing
Safety glass (low iron), 4mm
Insulation
60mm rear / 30mm sides Mineral wool
Solar fluid
Water / propylene glycol
Flow / return connections
G½" (flat face)
Technical Data - Clearly Solar Twin Coil Cylinder M odel
F l u ro c y l
C lea r ly sola r cy lind er s
200
250
300
1499 / 554/ 598
1789 /554 /558
2109 / 554 / 598
430
430
430
39 / 245
44 / 310
49 / 340
Capacity (l)
200
250
300
Reheat capacity (boiler) (%)
63
63
60
D imen si o n s a n d we igh t s Height / Width / Depth* (mm) Length of the immersion heater (mm) Weight empty / full (kg)
Technical Help: 01773 828300 Aftersales Service: 01773 828100
P er f o r m an c e
Heat up time (boiler) (mins)
21
26
30
Recovery time (boiler) (mins)
13
16
21
Heat loss (kW/24h)
1.9
2.1
2.4
Max mains inlet pressure (bar)
10
10
10
Pressure reducing valve setting (bar)
3.5
3.5
3.5
Expansion relief valve setting (bar)
6.0
6.0
6.0
T&P relief valve settings (°C / bar)
95 / 7.0
95 / 7.0
95 / 7.0
Specifications: 01773 824639 Training: 01773 596156 Sales Office: 01773 596020 Literature: 01773 596190
S a fe t y
www.clearlysolar.co.uk
C onnections Mains inlet / hot water outlet ** (mm)
22
22
22
Balanced cold water outlet** (mm)
22
22
22
Boiler flow / return** (mm)
22
22
22
Solar flow / return** (mm)
22
22
22
240V (50Hz)
240V (50Hz)
240V (50Hz)
240V (50Hz)
240V (50Hz)
240V (50Hz)
Thermostats & thermal cut outs (V (Hz)) Immersion heater & motorised valve (V (Hz))
* excluding clearances for connecting fittings / pipework
**
Nottingham Road, Belper, Derbys DE56 1JT www.glow-worm.co.uk
compression fittings supplied
13 GWSOLARBRO-1007