AIR HANDLING UNIT REFURBISHMENT/ HEAT EXCANGER PROTECTION Services
Before
After
OUTSIDE HUMIDITY
35°C 45°C
90% 40%
22º C
Inside
PROVIDED BY HEINEN & HOPMAN
1
Air Handling Unit refurbishment / Heat exchanger protection - HEINEN & HOPMAN 2020 ©
Heating
Ventilation
Air Conditioning
Refrigeration
COMPANY INTRODUCTION Heinen & Hopman is a reliable partner in the global maritime sector, offering top quality products and service in the field of climate control (HVAC & Refrigeration). The no-nonsense and entrepreneurial character of the founders who established the company in 1965 is still one of the main cornerstones of Heinen & Hopman. We support our clients using our knowledge and experience by realising the best possible climate control solutions; either fully customised or with varying degrees of standardisation. Like our clients, we are continuously active on a global scale to ensure that we can always be of service. We are also constantly searching for sustainable innovations as we aim for the best and very latest solutions in collaboration with our clients. Heinen & Hopman is critically aware that a company’s greatest asset is its employees – it is they who represent the added value of our business. Our goal is to continue to expand in the global market for maritime climate control solutions in a future-proof way. In short, you can rely on Heinen & Hopman to deploy the know-how and expertise required to solve any heating, ventilation, air conditioning and refrigeration issue onboard ships. We see complexity as a challenge, no matter where your vessel may be.
OPERATING GLOBALLY Global networking is crucial in every line of business and the shipping industry is certainly no exception. Being able to offer the highest quality of service and products to our clients at all times and in all places is of enormous importance to us. This is why Heinen & Hopman aims to keep expanding our network and know-how and ensure we are exactly where our clients need us to be.
Europe 22 Offices
1200 Employees
4
Factories
11
Countries
Americas 11 Offices
1
220 Employees
3
Countries
3
Factories
Air Handling Unit refurbishment / Heat exchanger protection - HEINEN & HOPMAN 2020 ©
Asia 10 Offices
380 Employees
7
Factories
7
Countries
AHU RENOVATION Air handling units are used for the offshore and marine industry and are crucial installations for creating an optimal climate in all kinds of environments. These installations provide the air we breathe and control the temperature and humidity in the places we live and work. It is clear that these ‘lungs’ must be kept in optimal condition. This will result in an optimal indoor climate, controlled energy consumption and a long lifetime of this expensive equipment. The air handling units are specially designed to be compact and allow for fitting in the often limited space of ships, yachts and offshore modules. The fans are made of high-quality materials to withstand the extreme sea climate conditions. The air handling unit is made of the most sturdy materials to withstand extreme cold or hot and humid air conditions, the salt sea air and the extreme environments. Application With the huge volumes of outside air which pass an average air supply installation, comes the threat of equipment degradation. While installations might look like they are in good condition from the outside, inside severe problems can be found. Corrosion can be found in almost every air handling unit due to the aggressive pollutants in outside air that are even able to pass through high quality filters. A thorough inspection will show the most critical points in your fresh air supply system. Heinen & Hopman specializes in air handling unit refurbishment to offer clients an add-on to their standard maintenance program for climate installations. Detailed working procedures have been developed to cope with all possible conditions. Per section, different measures are taken to bring equipment back to pristine condition and nominal performance. Because every air handler is different in set-up, condition, location and requirements Heinen & Hopman applies tailor made solutions for every project. Thorough cleaning and disinfection procedures are applied to remove persistent residues that are present even after standard maintenance. Specially developed coatings are used to treat corroded parts resulting in smooth and seamless surfaces for the fresh air to pass through. Damaged insulation and other deteriorated or outdated parts are replaced to make sure the unit is set for years of service. Heinen & Hopman working methods and project planning minimize nuisance while applying its services to climate installations. A total refurbishment is a cheaper, easier and faster option than replacement of complex air supply installations. A Heinen & Hopman refurbishment will revitalize your equipment. After this, a standard maintenance regimen is enough to keep the unit running in optimal condition With guaranteed fresh air supply for many years. Old New
2
Air Handling Unit refurbishment / Heat exchanger protection - Air HEINEN Handling & HOPMAN Unit refurbishment 2020 © / Heat exchanger protection - HEINEN & HOPMAN 2020 ©
2
HEAT EXCHANGER PROTECTION Bacteria may grow anywhere, if the conditions are suitable, but cannot be trapped by filters or sieves. Bacteria may develop and grow in the presence of sulphur-, nitrogenor phosphorousbased compounds. In addition, the tubes in the condenser are among the hottest points in the refrigerant circuit, and therefore bacterial flora finds the most favourable conditions for growth in such tubes. Also in this case, the deposit of bacterial flora affects heat exchange and may be the cause of corrosion. Preventing the action of bacteria is not easy, as even “clean” water may over time give rise to the formation of bacterial flora. To prevent this phenomenon, continuous checks must be made on all the components in the water circuit. Air-cooled heat exchangers suffer from corrosive attack in all kinds of environments. This corrosive attack results into high pressure failures, capacity loss, leakages and increased power consumption. Air-conditioning installations, power generation plants, oil & gas industry all depend on heat exchanging elements for a high efficiency and reduced down time. Application Standard corrosive protective systems cannot be applied on heat exchangers. This is because of the complexity of the elements and the risk of capacity loss due to thick insulating coating layers. Blygold has developed a revolutionary way to protect these vulnerable elements against failures and to ensure a long lasting efficiency. Next to the special heat conducting coating the application technique is crucial for protecting all metal surfaces in a heat exchanger. The Heinen & Hopman spray technique cannot be compared to any other spray applied coating because the airflow technology creates a remarkable coating penetration without bridging. Due to the Heinen & Hopman spray technology the coating can be applied either in-house or on-site. Heinen & Hopman protective system will at least double the heat exchangers lifetime but more often will triple it.
3
Air Handling Unit refurbishment / Heat exchanger protection - HEINEN & HOPMAN 2020 ©
4
Air Handling Unit refurbishment / Heat exchanger protection - HEINEN & HOPMAN 2020 ©
Austria T: +43 1720 1309 E: info@drewsmarine.com Brazil T: +55 213 587 4241/4244 E: info@br.heinenhopman.com Canada T:+1 450 659 6571 E: info@bronswerkgroup.com Denmark T: +45 5164 1614 E: admin@teknotherm.no France - La Ciotat T: +33 4 4204 8685 E: info@heinenhopmanfrance.com France - Antibes T: +33 4 8902 4562 E: info@heinenhopmanfrance.com Germany T:+49 4073 1680 E: info@drewsmarine.com Germany T:+49 471 9869 300 E: info@moehringms.com
India T: +91 336 499 1293 E: info@heinenhopmanindia.com Italy T: +39 187 187 8500 E: info@it.heinenhopman.com The Netherlands (HQ) T: +31 33 299 2500 E: info@heinenhopman.com The Netherlands - Rotterdam T: +31 18 020 9210 E: binnenvaart@heinenhopman.nl Norway T: +47 6919 0900 E: admin@teknotherm.no Peoples Republic of China T: +86 213 253 2896 E: info@cn.heinenhopman.com Peoples Republic of China T: +86 510 8528 1763 E: admin@teknotherm.no Poland T: +48 914 331 800 E: admin@teknotherm.no
UAE - Dubai T: +971 4263 5453 E: info@caspuae.com USA - Seattle, Washington T: +1 206 632 7883 E: sales.uk@teknotherm.com USA - Fort Lauderdale, Florida T: +1 954 463 0110 E: info@arwmaritime.com USA - Houma, Louisiana T: +1 985 876 7982 E: leblanc@leblancandassociates.com
Romania T: +40 236 448 222 E: office@ro.heinenhopman.com Russia T: +7 812 449 3535 E: info@heinenhopman.ru Singapore T: +65 6897 7879 E: info@sg.heinenhopman.com South Korea T: +82 704 901 0000 E: info@kr.heinenhopman.com Spain T: +34 932 259 668 E: info@es.heinenhopman.com Sweden T: +46 3121 7500 E: admin@teknotherm.no Turkey T: +90 216 493 8118 E: info@tr.heinenhopman.com UAE - Abu Dhabi T:+971 2550 4147 E: info@caspuae.com
Heinen & Hopman encourages a more sustainable world. By providing eco-friendly solutions and services we offer our clients the option of reducing energy consumption and thus CO2 emissions.
you require more information “ Do about our services or would you like to know more about our 24/7 contracts? I am keen to help you further!
“
Armin Bock
-
Manager Maintenance, Repair & Overhaul mro@heinenhopman.com
OUTSIDE HUMIDITY
35°C 45°C
90% 40%
22º C
Inside
PROVIDED BY HEINEN & HOPMAN
www.heinenhopman.com 5
Air Handling Unit refurbishment / Heat exchanger protection - HEINEN & HOPMAN 2020 ©
Heating
Ventilation
Air Conditioning
Refrigeration