Dampers AL

Page 1

DAMPERS - AL Products

OUTSIDE HUMIDITY

35°C 45°C

90% 40%

22º C

Inside

PROVIDED BY HEINEN & HOPMAN

1

Dampers - AL - HEINEN & HOPMAN 2020 ©

Heating

Ventilation

Air Conditioning

Dampers - AL - HEINEN & HOPMAN 2020 ©

Refrigeration

1


COMPANY INTRODUCTION Heinen & Hopman is a reliable partner in the global maritime sector, offering top quality products and service in the field of climate control (HVAC & Refrigeration). The no-nonsense and entrepreneurial character of the founders who established the company in 1965 is still one of the main cornerstones of Heinen & Hopman. We support our clients using our knowledge and experience by realising the best possible climate control solutions; either fully customised or with varying degrees of standardisation. Like our clients, we are continuously active on a global scale to ensure that we can always be of service. We are also constantly searching for sustainable innovations as we aim for the best and very latest solutions in collaboration with our clients. Heinen & Hopman is critically aware that a company’s greatest asset is its employees – it is they who represent the added value of our business. Our goal is to continue to expand in the global market for maritime climate control solutions in a future-proof way. In short, you can rely on Heinen & Hopman to deploy the know-how and expertise required to solve any heating, ventilation, air conditioning and refrigeration issue onboard ships. We see complexity as a challenge, no matter where your vessel may be.

OPERATING GLOBALLY Global networking is crucial in every line of business and the shipping industry is certainly no exception. Being able to offer the highest quality of service and products to our clients at all times and in all places is of enormous importance to us. This is why Heinen & Hopman aims to keep expanding our network and know-how and ensure we are exactly where our clients need us to be.

Europe 22 Offices

1200 Employees

4

Factories

11

Countries

Americas 11 Offices

1

Dampers - AL - HEINEN & HOPMAN 2020 ©

220 Employees

3

Countries

3

Factories

Asia 10 Offices

380 Employees

7

Factories

7

Countries

Dampers - AL - HEINEN & HOPMAN 2020 ©

1


DAMPERS There are different types of AL dampers: • Fire and gas dampers • Shut-off dampers • Smoke dampers • Non-return valves • Non-return dampers • Air-flow diffusers Fire and gas dampers Fire and gas dampers prevent the spread of fire, smoke and gas between ventilation ductwork, where people must have the maximum amount of time to react to possible fire. The dampers are type-approved according to A-0 (A-60).

ALFD fire and gas dampers Frame: Hot-dip galvanized steel. Thickness: 3-5 mm. Blades: opposed blades filled with fireresistant mineral wool sealed with thermal expanding gasket. Sizes: 100x100 ~ 1400x1500 mm. Operation system: electrical, pneumatic or manual. Shut-off dampers ALCT shut-off dampers shut off the airflow in ductwork. The dampers can be used as functional isolating dampers or as fire closure of main external ventilation openings as required by SOLAS.

ALCT shut-off dampers Frame: Hot-dip galvanized steel. (Preservation with set of marine paints available on request.) Thickness: 5 mm (other available on request). Blades: Hot-dip galvanized steel. Sizes: defined by customer. Operation system: electrical, pneumatic or manual. Modules possible. Smoke dampers ALSD smoke dampers prevent the spread of smoke and gases through the pipework in case of fire.

ALSD smoke dampers Frame: Hot-dip galvanized steel. Thickness: 3 mm. Blades: Hot-dip galvanized steel. Rotary flap peripheral sealed with rubber gasket. Circular connection pieces: DN 80 ~ DN 250. Operation system: electrical, pneumatic or manual. Modules possible.

2

Dampers - AL - HEINEN & HOPMAN 2020 ©


Non-return valves ALNV non-return valves are installed in ventilation ductwork of ships and off-shore objects to prevent the backflow of air through the ventilation ducts.

ALNV non-return valves Frame: Hot-dip galvanized steel. (Preservation with set of marine paints or stainless steel available on request.) Thickness: 1-2 mm. Blades: Hot-dip galvanized steel. Sizes: 100x100 ~ 400x800 mm. Operation system: by static air pressure. Non-return dampers ALND non-return dampers are installed in ventilation ductwork of ships and off-shore objects to prevent the backflow of air through the ventilation ducts.

ALND non-return dampers Frame: Hot-dip galvanized steel. (Preservation with set of marine paints or stainless steel available on request.) Thickness: 1-2 mm. Blades: Hot-dip galvanized steel. Size: defined by customer. Operation system: by static air pressure. Maximum pressure across the dampers: 4000 Pa. Maximum air velocity: 16 m/s. Air flow diffusers ALAD air flow diffusers are installed in ventilation ductwork of seagoing ships and off-shore objects. ALAD air flow diffusers enable adjustment of the supplied air flow direction or the closing air supply.

ALAD air flow diffusers Frame: Hot-dip galvanized steel. (Preservation with set of marine paints or stainless steel available on request.) Thickness: 2 mm. Blades: Hot-dip galvanized steel. Size: defined by customer. Operation system: by static air pressure. Maximum pressure across the dampers: 1000 Pa. Maximum air velocity: 12 m/s. Control The dampers can be controlled electrically, pneumatically or manually. In case of fire, the fire and gas dampers will close automatically. The electrically and pneumatically controlled dampers are driven by an actuator. Belimo actuators: as standard actuator. Schischek actuators: actuator used in explosion-proof areas or if the actuator must open/close within 3 s/90°. Classification ALFD • RMRS

3

• GL

Dampers - AL - HEINEN & HOPMAN 2020 ©

• ISO 9001

• ABS

Dampers - AL - HEINEN & HOPMAN 2020 ©

3


ALFD FIRE AND GAS DAMPERS ALFD fire and gas dampers prevent the spread of fire, smoke and gas between the ventilation ductwork, where people must have the maximum amount of time to react to possible fire. The dampers are type-approved according to A-0 (A60). The dampers have a flanged steel casing with opposed blades with thermal expanding gasket. The fail-safe is made by a thermal release device which operates if the temperature inside the duct increases above 72 °C (optionally 90 °C). If the power supply is interrupted, a spring return actuator closes the blade. The actual position of the blade is marked on the casing. The dampers have electric or pneumatic actuators, both with a single-action return spring. Electric actuator: 24V or 230V | 50/60 Hz | IP54 | 3-8 W | release time 20 s, reset time 150 s Pneumatic actuator: 5-8 bar | release time < 5 s, reset time < 5 s Electrically and pneumatically controlled dampers are manufactured in standard and explosion-proof executions, with non-sparking movable co-operating elements and EExdIICT6-class electrical equipment. Part

Material

Finishing

Frame

Steel

Painted or galvanized

Blades

Steel, filled with resistant mineral wool

Galvanized

Bearings

Galvanized steel / Stainless steel (optional)

-

Shafts

Galvanized steel / Stainless steel (optional)

-

Dimensions and material thickness ALFD The dampers have been fire-tested in accordance with approval procedure in IMO resolution A.754(18) 1994. Certificates • Lloyds Approval Certificate NO 50 7000 03 HH • EC-type examination • Mark of Conformity 0801-03 (MED) Frame thickness according to SOLAS BxH

100 x 100 ~ 1400 x 1500

For B or H mm

S mm

100 - 315

3

400 - 500

4

630 - 1500

5

L mm

C mm

D mm

220

200

100

Standard execution

210

Dampers with EExd electrical actuator

300

230

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 4

Dampers - AL - HEINEN & HOPMAN 2020 ©

Dampers - AL - HEINEN & HOPMAN 2020 ©

4


ALCT SHUT-OFF DAMPERS ALCT shut-off dampers shut off the airflow in ductwork. The dampers can be used as functional isolating dampers or as fire closure of main external ventilation openings as required by SOLAS. The dampers have a mild-steel frame and rotary blades actuated electrically, pneumatically or manually. The voltage or the working pressure of the control air must be specified at order. Drive: EL24 – electric actuator 24V EL230 – electric actuator 230V PN – pneumatic actuator MAN - manual

Part

Material

Finishing

Frame

Steel

Galvanized

Paints available on request

Blades

Steel

Galvanized

-

Bearings

Steel

Galvanized

-

Shafts

Steel

Galvanized

-

Dimensions and material thickness The thickness of the blades and the casing is 5 mm, other available on request. The dimensions BxH must be defined by the customer.

ALSD SMOKE DAMPERS

ALSD smoke dampers prevent the spread of smoke and gases through the pipework in case of fire. The dampers have a steel casing with spiro pipe connections on both ends and with a manually operated rotary flap, peripherally sealed with a rubber gasket. The actual open/closed position is secured with a fixing spring and labeled on the casing. Part

Material

Finishing

Frame

Steel

Hot-dip galvanized

Frame

Steel

Painted on request

Blades

Mild steel

Hot-dip galvanized

Bearings

Stainless steel

-

Shafts

Stainless steel

-

Dimensions and material thickness The thickness of the blades and the casing is 3 mm.

5

DN

ØAxG

L mm

B mm

Weight (kg)

80

86x3

120

110

1.08

100

106x3

120

125

1.32

125

131x3

130

140

1.95

160

166x3

140

160

2.68

200

206x3

160

185

4.05

250

256x3

180

210

6.10

Dampers - AL - HEINEN & HOPMAN 2020 ©

Dampers - AL - HEINEN & HOPMAN 2020 ©

5


ALNV NON-RETURN VALVES

ALNV non-return valves are installed in ventilation ductwork of ships and off-shore objects to prevent the backflow of air through the ventilation ducts. The valves must be installed horizontally or vertically. Performance chart (air static pressure that opens the flap)

Part

Material

Finishing

Frame

Steel

Hot-dip galvanized

Blades

Aluminium

-

Bearings

Stainless steel

-

Shafts

Stainless steel

-

H mm

B mm

L mm

G mm

S mm

100 100

160 200

3,5 240

2

1

250

160

315

300

400

1 3

250 200

350

1 3

400

630

12

3

1

450

800

2 4

500 630

13,3 12,2

3

800

400

9,7

15,6

400 315

7,8

11,8

630

500

7,3 5,5

400 500

6,1 9,1

2

500

250

4,4 5,3

2

400 315

3,9 4,9

200 250

Weight kg

17,3 2

4

18 19,8

3 560

14,1

19,8 22,5

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 6

Dampers - AL - HEINEN & HOPMAN 2020 ©

Dampers - AL - HEINEN & HOPMAN 2020 ©

6


ALND NON-RETURN DAMPERS ALND non-return dampers are installed in ventilation ductwork of ships and off-shore objects to prevent the backflow of air through the ventilation ducts. The dampers do not require an actuator or motor. The dampers must be installed horizontally or vertically. The dampers can be easily adjusted by adjusting the weight of each damper/installation or by adjusting the weights fitted to the blade shafts. The minimum opening force can be easily adjusted by the counterweights fitted to the blade shafts. • Standard construction places weights on the right-hand side. Weights on the left-hand side are available as an option. • Maximum duct pressure: 4000 Pa. Maximum air velocity: 16 m/s. Material

Finishing

Note

Steel

Galvanized

Painted or stainless steel on request

Steel

Galvanized

Painted or stainless steel on request

Bearings

Stainless steel

-

-

Shafts

Stainless steel

-

-

Part Frame Blades

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 7

Dampers - AL - HEINEN & HOPMAN 2020 ©

Dampers - AL - HEINEN & HOPMAN 2020 ©

7


ALAD AIR FLOW DIFFUSERS ALAD air flow diffusers are installed in ventilation ductwork of seagoing ships and off-shore objects. The diffusers enable adjustment of the supplied air flow direction or the closing air supply. The diffusers have a flanged casing with rotary shutter blades made of galvanized steel sheet. The diffusers have a protecting wire guard fitted to the air outlet side. • The blades can be fixed in any position between 0° (diffuser closed) and 130°. • Maximum pressure across the dampers: 1000 Pa. Maximum air velocity: 12 m/s. Material

Finishing

Note

Steel

Galvanized

Painted or stainless steel on request

Steel

Galvanized

Painted or stainless steel on request

Bearings

Stainless steel

-

-

Shafts

Stainless steel

-

-

Part Frame Blades

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 8

Dampers - AL - HEINEN & HOPMAN 2020 ©

Dampers - AL - HEINEN & HOPMAN 2020 ©

8


Austria T: +43 1720 1309 E: info@drewsmarine.com Brazil T: +55 213 587 4241/4244 E: info@br.heinenhopman.com Canada T:+1 450 659 6571 E: info@bronswerkgroup.com Denmark T: +45 5164 1614 E: admin@teknotherm.no France - La Ciotat T: +33 4 4204 8685 E: info@heinenhopmanfrance.com France - Antibes T: +33 4 8902 4562 E: info@heinenhopmanfrance.com Germany T:+49 4073 1680 E: info@drewsmarine.com Germany T:+49 471 9869 300 E: info@moehringms.com

India T: +91 336 499 1293 E: info@heinenhopmanindia.com Italy T: +39 187 187 8500 E: info@it.heinenhopman.com The Netherlands (HQ) T: +31 33 299 2500 E: info@heinenhopman.com The Netherlands - Rotterdam T: +31 18 020 9210 E: binnenvaart@heinenhopman.nl Norway T: +47 6919 0900 E: admin@teknotherm.no Peoples Republic of China T: +86 213 253 2896 E: info@cn.heinenhopman.com Peoples Republic of China T: +86 510 8528 1763 E: admin@teknotherm.no Poland T: +48 914 331 800 E: admin@teknotherm.no

Heinen & Hopman encourages a more sustainable world. By providing eco-friendly solutions and services we offer our clients the option of reducing energy consumption and thus CO2 emissions.

Romania T: +40 236 448 222 E: office@ro.heinenhopman.com Russia T: +7 812 449 3535 E: info@heinenhopman.ru Singapore T: +65 6897 7879 E: info@sg.heinenhopman.com South Korea T: +82 704 901 0000 E: info@kr.heinenhopman.com Spain T: +34 932 259 668 E: info@es.heinenhopman.com Sweden T: +46 3121 7500 E: admin@teknotherm.no Turkey T: +90 216 493 8118 E: info@tr.heinenhopman.com UAE - Abu Dhabi T:+971 2550 4147 E: info@caspuae.com

UAE - Dubai T: +971 4263 5453 E: info@caspuae.com USA - Seattle, Washington T: +1 206 632 7883 E: sales.uk@teknotherm.com USA - Fort Lauderdale, Florida T: +1 954 463 0110 E: info@arwmaritime.com USA - Houma, Louisiana T: +1 985 876 7982 E: leblanc@leblancandassociates.com

you require more information “ Do about our products or do you

require advice? I am keen to help you further!

Bas Veltman

-

Sales Manager sales@heinenhopman.com

OUTSIDE HUMIDITY

35°C 45°C

90% 40%

22º C

Inside

PROVIDED BY HEINEN & HOPMAN

www.heinenhopman.com 9

Dampers - AL - HEINEN & HOPMAN 2020 ©

Heating

Ventilation

Air Conditioning

Dampers - AL - HEINEN & HOPMAN 2020 ©

Refrigeration

9


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.