SELF CONTAINED UNITS - AM Products
OUTSIDE HUMIDITY
35°C 45°C
90% 40%
22º C
Inside
PROVIDED BY HEINEN & HOPMAN
1
Heating
Ventilation
Air Conditioning
Refrigeration
1
COMPANY INTRODUCTION Heinen & Hopman is a reliable partner in the global maritime sector, offering top quality products and service in the field of climate control (HVAC & Refrigeration). The no-nonsense and entrepreneurial character of the founders who established the company in 1965 is still one of the main cornerstones of Heinen & Hopman. We support our clients using our knowledge and experience by realising the best possible climate control solutions; either fully customised or with varying degrees of standardisation. Like our clients, we are continuously active on a global scale to ensure that we can always be of service. We are also constantly searching for sustainable innovations as we aim for the best and very latest solutions in collaboration with our clients. Heinen & Hopman is critically aware that a company’s greatest asset is its employees – it is they who represent the added value of our business. Our goal is to continue to expand in the global market for maritime climate control solutions in a future-proof way. In short, you can rely on Heinen & Hopman to deploy the know-how and expertise required to solve any heating, ventilation, air conditioning and refrigeration issue onboard ships. We see complexity as a challenge, no matter where your vessel may be.
OPERATING GLOBALLY Global networking is crucial in every line of business and the shipping industry is certainly no exception. Being able to offer the highest quality of service and products to our clients at all times and in all places is of enormous importance to us. This is why Heinen & Hopman aims to keep expanding our network and know-how and ensure we are exactly where our clients need us to be.
Europe 29 Offices
1250 Employees
8
Factories
13
Countries
Americas 12 Offices
1
240 Employees
5
Factories
3
Countries
Asia 16 Offices
320 Employees
6
Factories
7
Countries
1
VK SELF-CONTAINED MARINE TYPE AIR CONDITIONING UNIT • • • • • • • •
•
Nominal cooling loads: 3.5 kW / 5.25 kW / 7.0 kW and 10.50 kW Sea water / fresh water cooled through shell and tube condenser Refrigerant R404a, R448A or R449A Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) Removable top and side panels for access and maintenance Quick release grille for air filter cleaning and replacement Units supplied factory pre-charged only requiring suitable water and electrical connections Electrical supply - 220V 1ph 50/60Hz - 380V 3ph 50Hz - 440V 3ph 60Hz Available options - Refrigerant: R134a or R404a - Fresh-water plate heat exchanger - Color to suit operating environment - Electrical heating VK12
VK18
VK24
Nominal cooling load (kW)
3.50
5.25
7.00
10.5
Nominal air flow - low (m3/h) - high (m3/h)
400 500
500 675
800 1000
1200 1500
Fan motor rating (kW)
0.037
0.045
0.074
0.111
Compressor motor power (kW)
1.76
2.30
4.40
4.39
Nominal sea-water quantity (m3/h)
0.43
1.30
2.74
5.46
Nominal fresh-water quantity (m3/h)
1.22
0.59
1.62
2.18
Dimensions
VK36
H (mm)
450
550
550
650
W (mm)
760
760
1060
1360
D (mm)
380
380
380
400
Weight (kg)
85
95
130
160
Electric heating (optional) (kW)
1.5
1.5
3.0
4.5
Nominal duties are based on air entering @ 250C Cdb @ 50% RH utilising R407c with sea water @ 320C W
H
D
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 2
2
VK AIR-COOLED AIR CONDITIONING UNIT • • • • •
• • • •
•
Nominal cooling loads: 3.5 kW / 5.25 kW / 7.0 kW Air-cooled Refrigerant R407c / R448A / R449A Internal section - Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) External section - Stainless-steel 316 casing with powder-coated paint finish RAL 9018 (grey) - Condenser fan motors to IP56 - Cu/Cu condenser coil Removable top and side panels for access and maintenance Quick-release grille for air filter cleaning and replacement Units supplied factory pre-charged Electrical supply - 220V 1ph 50/60Hz - 380V 3ph 50Hz - 440V 3ph 60Hz Available options - Internal section stainless-steel 316 casing with powder-coated finish RAL 9018 (grey) - Color to suit operating environment - Split system version - Electric heating - Refrigerant R134a VK12
VK18
VK24
VK36
Nominal cooling load (kW)
3.5
5.25
7.00
10.50
Nominal air flow - low (m3/h) - high (m3/h)
400 500
500 675
800 1000
1200 1500
Evaporator Fan motor rating (kW)
0.037
0.045
0.074
0.111
Compressor motor power (kW)
1.87
2.28
2.89
2.55
Condenser fan motor rating (kW)
0.18
0.25
2 @ 0.18
2 @ 0.37
Dimensions
H (mm)
450
550
550
650
W (mm)
760
760
1060
1360
D (mm)
380
380
380
400
Weight (kg)
145
160
210
335
Electric heating (optional) (kW)
1.5
1.5
3.0
3.0
Nominal duties are based on air entering @ 25 C Cdb @ 50% RH utilising R407c and ambient air @ 40 C 0
D
0
W
W
H
H
D
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 3
3
TR SELF-CONTAINED MARINE AIR CONDITIONING UNIT • • • • • • • • • •
Nominal cooling loads 7.0 kW to 70.0 kW Sea water / fresh water cooled through shell and tube condenser Refrigerant R407c / R448A / R449A Spigoted duct connection Electro coated mild steel casing with powder coated paint finish RAL 9018 (Grey) Removable panels for access and maintenance Quick release grille for air filter cleaning and replacement Units supplied factory precharged only requiring suitable water and electrical connections Electrical supply - 380V 3ph 50Hz - 440V 3ph 60Hz Other options available - Color to suit operating environment - Fresh air connection - Fan pressures to suit application - Electric heating - Non-standard electric supply - Plenum and grille discharge - Air flow through base of unit (Downward discharge) - Refrigerant R134a or R404A TR02
Nominal cooling load (kW) Nominal air flow (m3/h)
TR03
TR05
TR08
TR10
TR15
TR20
7.0
10.5
17.5
28.0
35.0
56.0
70.0
1080
1530
2550
4075
5100
7725
10200
Plenum discharge fan motor rating (kW)
0.18
0.37
0.55
1.10
1.50
2.20
3.00
Compressor motor power (kW)
4.39
7.32
5.88
10.20
11.90
18.30
24.40 17.36
Nominal sea-water quantity (m3/h)
1.27
2.39
2.61
4.84
10.30
12.58
Nominal fresh-water quantity (m3/h)
0.91
1.16
1.49
2.60
3.65
5.22
6.19
Dimensions
H (mm)
1300
1300
1600
1800
1800
2000
2100
W (mm)
900
900
900
1100
1250
1400
1800
D (mm)
450
450
550
650
650
850
850
P (mm)
110
120
180
230
230
300
330
169
193
246
312
365
557
668
1 x 3.0
1 x 4.5
2 x 4.5
2 x 9.0
2 x 9.0
3 x 9.0
4 x 9.0
Weight (kg) Electric heating (optional) (kW)
Nominal duties are based on air entering @ 240C Cdb @ 50% RH utilising R134a with sea water @ 320C D
H
P
W
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 4
4
TRA AIR-COOLED SPLIT MARINE AIR CONDITIONING UNIT • • • • • •
Nominal cooling loads: 10.5 kW - 70.0 kW Air-cooled Refrigerant R407c / R448A / R449A TR02 to TR10 fitted with hermetic compressor TR15 & TR20 fitted with semi-hermetic compressors with capacity control Internal section - Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) - Removable panels for access and maintenance - Quick-release grille for air filter cleaning and replacement • External section - Electro-coated mild-steel with powder-coated paint finish RAL 9018 (grey) - Condenser coil with Cu tubes and Cu fins • Electrical supply - 380V 3ph 50 Hz - 440V 3ph 60Hz • Available options - Color to suit operating environment - Refrigerant R134a - Fan pressures to suit application - External section with horizontal air flow - Electric heating - Interconnecting piping cable - Non-standard electric supply TRA08
TRA10
TRA15
Nominal cooling load (kW)
10.5
17.5
28.0
35.0
56.0
70.0
Nominal air flow evaporating (m3/h)
1530
2550
4075
5100
7725
10200
Plenum discharge fan motor rating (kW)
0.37
0.55
1.10
1.50
2.12
3.00
Compressor motor power (kW)
3.55
5.48
9.79
10.94
19.58
21.88
Nominal condensing load (kW)
14.42
21.42
33.24
47.44
77.78
94.88
Nominal air-flow condensing (m3/h)
6624
9360
14400
21600
28080
37440
Condenser fan motor rating (kW)
2 @ 0.37
2 @ 0.55
2 @ 0.75
3 @ 0.58
3 @ 0.75
4 @ 0.75
1 x 4.5
2 x 4.5
2 x 9.0
2 x 9.0
3 x 9.0
4 x 9.0
Electric heating (optional) (kW)
W
TRA20
D
P
TRA05
H
TRA03
Dimensions
H (mm)
1300
1600
1800
1800
2000
2100
W (mm)
900
900
1200
1250
1400
1800
D (mm)
450
550
650
650
850
850
P (mm)
120
180
230
230
300
330
178
219
284
328
501
594
Weight (kg)
H
Internal section
External section Dimensions
H (mm)
1380
1400
1420
1400
1420
1420
W (mm)
1200
1400
1700
2400
2600
3200
D (mm)
700
800
900
900
1100
1100
154
200
253
290
409
Weight (kg)
W
D
528
Nominal duties are based on air entering @ 35 C Cdb @ 50% RH utilising R407c with ambient air @ 40 C 0
0
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 5
5
KW SELF-CONTAINED MARINE AIR CONDITIONING UNIT • • • • • • • •
Nominal cooling loads: 10.0 kW - 25.0 kW Fresh-water-cooled through plate heat exchanger Refrigerant R404C / R449A / R448A Spigoted duct connection Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) Removable front panel for access and maintenance Quick-release grille for air filter cleaning and replacement Units supplied factory pre-charged only requiring suitable water and electrical connections • Electrical supply - 380V 3ph 50Hz - 440V 3ph 60Hz • Available options - Sea-water-cooled through coaxial condenser - Fresh-air connection - Color to suit operating environment - Plenum and grille discharge - Electric or hot-water heating - Fan pressure to suit application - Refrigerant R134a or R404A W
KW20
10
15
20
25
1500
2200
2950
3700
Fan motor rating (kW)
0.37
0.55
0.75
1.1
Compressor motor power (kW)
4.34
4.50
4.90
6.48
Nominal fresh-water quantity (m3/h)
2.41
3.45
4.56
6.01
Dimensions
H (mm)
1500
1700
1950
1950
W (mm)
550
700
700
800
D (mm)
550
750
750
750
P (mm)
150
200
225
245
186
234
282
309
1 x 4.5
2 x 4.5
2 x 6.0
2 x 9.0
Weight (kg) Electric heating (optional) (kW)
D
KW25 P
Nominal cooling load (kW) Nominal air flow (m3/h)
KW15
H
KW10
Nominal duties are based on air entering @ 250C Cdb @ 50% RH utilising R407c with fresh water @ 360C
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 6
6
KWA AIR-COOLED MARINE AIR CONDITIONING UNIT • • • •
Nominal cooling loads: 10.0 kW - 30.0 kW Air-cooled Refrigerant R407C Internal section - Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) - Removable panels for access and maintenance - Quick-release grille for air filter cleaning and replacement • External section - Electro-coated mild-steel with powder-coated paint finish RAL 9018 (grey) - Condenser coil with Cu tubes and Cu fins • Electrical supply - 380V 3ph 50Hz - 440V 3ph 60Hz • Available options - Sea-water-cooled through coaxial condenser - Fresh-air connection - Color to suit operating environment - Electric heating - Fan pressure to suit application - Refrigerant R134a KWA10 Nominal cooling load (kW)
KWA15
KWA20
KWA25
KWA30
10
15
20
25
30
Nominal air flow (evaporating) (m3/h)
1500
2200
2950
3700
4800
Plenum discharge fan motor rating (kW)
0.37
0.55
0.55
1.10
1.10
Compressor motor power (kW)
3.55
5.48
5.48
9.79
9.79
Nominal condensing load (kW)
13.92
21.03
26.03
33.24
33.24
Nominal air flow (condensing) (m3/h)
6624
8022
10670
14400
14400
Condenser fan motor rating (kW)
2 @ 0.37
2 @ 0.55
2 @ 0.55
2 @ 0.75
2 @ 0.75
1 x 4.5
2 x 4.5
2 x 6.0
2 x 9.0
2 x 9.0
Electric heating (optional) (kW)
Internal section Dimensions
H (mm)
1500
1700
1950
1950
1950
W (mm)
550
700
700
800
1000
D (mm)
550
750
750
750
750
P (mm)
150
200
225
245
270
186
234
273
308
350
Weight (kg)
External section Dimensions
H (mm)
1380
1400
1400
1420
1420
W (mm)
1200
1400
1400
1700
1700
D (mm)
700
800
800
900
900
154
200
200
250
250
Weight (kg)
Nominal duties are based on air entering @ 350C Cdb @ 50% RH utilising R407c with ambient air @ 400C D
H
H
P
W
W
7
D
7
ACC (H&V) MARINE AIR-COOLED CONDENSER • Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) • Condenser coil with Cu and Cu fins • Refrigerant R407c • Electrical supply - 380V 3ph 50Hz - 440V 3ph 60Hz • Available options - Stainless-steel 316 casing - Protective coating to coil - Atex II 2 G Eex IIB T4 for hazardous areas - Refrigerant R134a ACCV5
ACCV8
ACCV10
ACCV15
15.00
22.00
34.00
48.00
78.00
ACCV20 95.00
Nominal air flow (m³/h)
6624
9360
14400
21600
28080
37440
Fan motor rating (total) (kW)
2 @ 0.37
2 @ 0.55
2 @ 0.75
3 @ 0.58
3 @ 0.75
4 @ 0.75
Dimensions (Vertical) H (mm)
1380
1400
1420
1400
1420
1420
W (mm)
1200
1400
1700
2400
2600
3200
D (mm)
700
800
900
900
1100
1100
154
200
253
290
409
528
ACCH20
Unit weight (kg)
H
ACCV3 Nominal condensing load (kW)
W
D
Nominal duties are based on ambient air @ 400C
ACCH5
ACCH8
ACCH10
ACCH15
15.00
22.00
34.00
48.00
78.00
95.00
Nominal air flow (m³/h)
6624
9360
14400
21600
28080
37440
Fan motor rating (total) (kW)
2 @ 0.37
2 @ 0.55
2 @ 0.75
3 @ 0.58
3 @ 0.75
4 @ 0.75
Dimensions (Vertical) H (mm)
900
1000
1100
1100
1300
1300
W (mm)
1200
1400
1700
2000
2600
3200
D (mm)
700
700
700
700
700
700
174
216
287
330
449
558
Unit weight (kg)
W
D
H
ACCH3 Nominal condensing load (kW)
Nominal duties are based on ambient air @ 40 C 0
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 8
8
FP AIR-COOLED HAZARDOUS AREA AIR CONDITIONING UNIT
•
•
• • • •
•
Nominal cooling loads: 3.5 kW / 5.25 kW / 7.0 kW Air-cooled Refrigerant R407c / R449A / R448A A60-class fire-resistant division between internal and external section Internal section - Suitable for non-hazardous area - Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) External section - ATEX II 2 G EEx d IIB T4 suitable for hazardous area - Cu/Cu condenser coil - Stainless-steel 316 casing with powder-coated paint finish RAL 9018 (grey) Removable top and side panels for access and maintenance Quick-release grille for air filter cleaning and replacement Units supplied factory pre-charged Electrical supply - 220V 1ph 50/60Hz - 380V 3ph 50Hz - 440V 3ph 60Hz Available options - Color to suit operating environment - Split system version - Electric heating - Refrigerant R134a FP12
FP18
FP24
Nominal cooling load (kW)
3.50
5.25
7.00
Nominal air flow - low (m3/h) - high (m3/h)
400 500
500 675
800 1000
Evaporator Fan motor rating (kW) Compressor motor power (kW) 480
0.037
Condenser fan motor ratingINTERNAL (kW) SECTION Dimensions H (mm)
0.18
W (mm)
1.87 450
0.045 460 2.28 0.25 EXTERNAL SECTION 550
480
460
INTERNAL SECTION
EXTERNAL SECTION
0.074 W
2.89 2@0.18 550
760
760
1060
Weight (kg)
125
135
195
Electric heating (optional) (kW)
1.5
1.5
3.0
Nominal duties are based on air entering @ 250C Cdb @ 50% RH utilising R407c with ambient air @ 400C
H
• • • •
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 9
9
KWG GALLEY SELF-CONTAINED AIR CONDITIONING UNIT • • • • • • • •
Unit designed to meet SOLAS requirements Nominal cooling loads: 10.0 kW / 25.0 kW Fresh-water-cooled through plate heat exchanger Refrigerant R407C / R449A / R448A Ducted, filtered rear inlet and vertical discharge Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) Removable panels for access and maintenance Units supplied factory pre-charged only requiring suitable water and electrical connections • Electric heating • Electrical supply - 380V 3ph 50Hz - 440V 3ph 60Hz • Available options - Stainless-steel 316 casing with powder-coated paint finish - Color to suit operating environment - Alternative fan pressures - Split system version - Hot-water heating - Refrigerant: R134a or R404A - Sea-water-cooled through coaxial condenser W
KWG15
KWG20
KWG25
Nominal cooling load (kW)
10.0
15.0
20
25
Nominal heating load (kW)
9.0
12.0
13.5
18.0 1550
Nominal air flow (m3/h)
600
700
1100
External pressure (kW)
600
600
600
600
Fan motor rating (kW)
0.37
0.37
0.55
0.75
Compressor motor power (kW)
3.55
4.72
6.45
9.79
Nominal water quantity (m3/h)
1.08
1.56
3.12
3.70
Dimensions
Weight (kg)
H (mm)
1500
1750
1750
1750
W (mm)
550
700
700
700
D (mm)
550
750
750
750
230
320
340
370
H
KWG10
D
Nominal duties are based on 100% fresh air entering @ 350C Cdb @ 70% RH (summer) and -250C (winter) utilising R407c with fresh water @ 360C
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 10
10
Heinen & Hopman encourages a more sustainable world. By providing eco-friendly solutions and services we offer our clients the option of reducing energy consumption and thus CO2 emissions.
you require more information “ Do about our products or do you
“
require advice? I am keen to help you further!
Paul Spoorenberg
-
Sales Manager sales@heinenhopman.com
OUTSIDE HUMIDITY
35°C 45°C
90% 40%
22º C
Inside
PROVIDED BY HEINEN & HOPMAN
www.heinenhopman.com 11
Heating
Ventilation
Air Conditioning
Refrigeration
11