Self contained units am

Page 1

SELF CONTAINED UNITS - AM Products

OUTSIDE HUMIDITY

35°C 45°C

90% 40%

22º C

Inside

PROVIDED BY HEINEN & HOPMAN

1

Heating

Ventilation

Air Conditioning

Refrigeration

1


COMPANY INTRODUCTION Heinen & Hopman is a reliable partner in the global maritime sector, offering top quality products and service in the field of climate control (HVAC & Refrigeration). The no-nonsense and entrepreneurial character of the founders who established the company in 1965 is still one of the main cornerstones of Heinen & Hopman. We support our clients using our knowledge and experience by realising the best possible climate control solutions; either fully customised or with varying degrees of standardisation. Like our clients, we are continuously active on a global scale to ensure that we can always be of service. We are also constantly searching for sustainable innovations as we aim for the best and very latest solutions in collaboration with our clients. Heinen & Hopman is critically aware that a company’s greatest asset is its employees – it is they who represent the added value of our business. Our goal is to continue to expand in the global market for maritime climate control solutions in a future-proof way. In short, you can rely on Heinen & Hopman to deploy the know-how and expertise required to solve any heating, ventilation, air conditioning and refrigeration issue onboard ships. We see complexity as a challenge, no matter where your vessel may be.

OPERATING GLOBALLY Global networking is crucial in every line of business and the shipping industry is certainly no exception. Being able to offer the highest quality of service and products to our clients at all times and in all places is of enormous importance to us. This is why Heinen & Hopman aims to keep expanding our network and know-how and ensure we are exactly where our clients need us to be.

Europe 29 Offices

1250 Employees

8

Factories

13

Countries

Americas 12 Offices

1

240 Employees

5

Factories

3

Countries

Asia 16 Offices

320 Employees

6

Factories

7

Countries

1


VK SELF-CONTAINED MARINE TYPE AIR CONDITIONING UNIT • • • • • • • •

Nominal cooling loads: 3.5 kW / 5.25 kW / 7.0 kW and 10.50 kW Sea water / fresh water cooled through shell and tube condenser Refrigerant R404a, R448A or R449A Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) Removable top and side panels for access and maintenance Quick release grille for air filter cleaning and replacement Units supplied factory pre-charged only requiring suitable water and electrical connections Electrical supply - 220V 1ph 50/60Hz - 380V 3ph 50Hz - 440V 3ph 60Hz Available options - Refrigerant: R134a or R404a - Fresh-water plate heat exchanger - Color to suit operating environment - Electrical heating VK12

VK18

VK24

Nominal cooling load (kW)

3.50

5.25

7.00

10.5

Nominal air flow - low (m3/h) - high (m3/h)

400 500

500 675

800 1000

1200 1500

Fan motor rating (kW)

0.037

0.045

0.074

0.111

Compressor motor power (kW)

1.76

2.30

4.40

4.39

Nominal sea-water quantity (m3/h)

0.43

1.30

2.74

5.46

Nominal fresh-water quantity (m3/h)

1.22

0.59

1.62

2.18

Dimensions

VK36

H (mm)

450

550

550

650

W (mm)

760

760

1060

1360

D (mm)

380

380

380

400

Weight (kg)

85

95

130

160

Electric heating (optional) (kW)

1.5

1.5

3.0

4.5

Nominal duties are based on air entering @ 250C Cdb @ 50% RH utilising R407c with sea water @ 320C W

H

D

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 2

2


VK AIR-COOLED AIR CONDITIONING UNIT • • • • •

• • • •

Nominal cooling loads: 3.5 kW / 5.25 kW / 7.0 kW Air-cooled Refrigerant R407c / R448A / R449A Internal section - Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) External section - Stainless-steel 316 casing with powder-coated paint finish RAL 9018 (grey) - Condenser fan motors to IP56 - Cu/Cu condenser coil Removable top and side panels for access and maintenance Quick-release grille for air filter cleaning and replacement Units supplied factory pre-charged Electrical supply - 220V 1ph 50/60Hz - 380V 3ph 50Hz - 440V 3ph 60Hz Available options - Internal section stainless-steel 316 casing with powder-coated finish RAL 9018 (grey) - Color to suit operating environment - Split system version - Electric heating - Refrigerant R134a VK12

VK18

VK24

VK36

Nominal cooling load (kW)

3.5

5.25

7.00

10.50

Nominal air flow - low (m3/h) - high (m3/h)

400 500

500 675

800 1000

1200 1500

Evaporator Fan motor rating (kW)

0.037

0.045

0.074

0.111

Compressor motor power (kW)

1.87

2.28

2.89

2.55

Condenser fan motor rating (kW)

0.18

0.25

2 @ 0.18

2 @ 0.37

Dimensions

H (mm)

450

550

550

650

W (mm)

760

760

1060

1360

D (mm)

380

380

380

400

Weight (kg)

145

160

210

335

Electric heating (optional) (kW)

1.5

1.5

3.0

3.0

Nominal duties are based on air entering @ 25 C Cdb @ 50% RH utilising R407c and ambient air @ 40 C 0

D

0

W

W

H

H

D

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 3

3


TR SELF-CONTAINED MARINE AIR CONDITIONING UNIT • • • • • • • • • •

Nominal cooling loads 7.0 kW to 70.0 kW Sea water / fresh water cooled through shell and tube condenser Refrigerant R407c / R448A / R449A Spigoted duct connection Electro coated mild steel casing with powder coated paint finish RAL 9018 (Grey) Removable panels for access and maintenance Quick release grille for air filter cleaning and replacement Units supplied factory precharged only requiring suitable water and electrical connections Electrical supply - 380V 3ph 50Hz - 440V 3ph 60Hz Other options available - Color to suit operating environment - Fresh air connection - Fan pressures to suit application - Electric heating - Non-standard electric supply - Plenum and grille discharge - Air flow through base of unit (Downward discharge) - Refrigerant R134a or R404A TR02

Nominal cooling load (kW) Nominal air flow (m3/h)

TR03

TR05

TR08

TR10

TR15

TR20

7.0

10.5

17.5

28.0

35.0

56.0

70.0

1080

1530

2550

4075

5100

7725

10200

Plenum discharge fan motor rating (kW)

0.18

0.37

0.55

1.10

1.50

2.20

3.00

Compressor motor power (kW)

4.39

7.32

5.88

10.20

11.90

18.30

24.40 17.36

Nominal sea-water quantity (m3/h)

1.27

2.39

2.61

4.84

10.30

12.58

Nominal fresh-water quantity (m3/h)

0.91

1.16

1.49

2.60

3.65

5.22

6.19

Dimensions

H (mm)

1300

1300

1600

1800

1800

2000

2100

W (mm)

900

900

900

1100

1250

1400

1800

D (mm)

450

450

550

650

650

850

850

P (mm)

110

120

180

230

230

300

330

169

193

246

312

365

557

668

1 x 3.0

1 x 4.5

2 x 4.5

2 x 9.0

2 x 9.0

3 x 9.0

4 x 9.0

Weight (kg) Electric heating (optional) (kW)

Nominal duties are based on air entering @ 240C Cdb @ 50% RH utilising R134a with sea water @ 320C D

H

P

W

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 4

4


TRA AIR-COOLED SPLIT MARINE AIR CONDITIONING UNIT • • • • • •

Nominal cooling loads: 10.5 kW - 70.0 kW Air-cooled Refrigerant R407c / R448A / R449A TR02 to TR10 fitted with hermetic compressor TR15 & TR20 fitted with semi-hermetic compressors with capacity control Internal section - Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) - Removable panels for access and maintenance - Quick-release grille for air filter cleaning and replacement • External section - Electro-coated mild-steel with powder-coated paint finish RAL 9018 (grey) - Condenser coil with Cu tubes and Cu fins • Electrical supply - 380V 3ph 50 Hz - 440V 3ph 60Hz • Available options - Color to suit operating environment - Refrigerant R134a - Fan pressures to suit application - External section with horizontal air flow - Electric heating - Interconnecting piping cable - Non-standard electric supply TRA08

TRA10

TRA15

Nominal cooling load (kW)

10.5

17.5

28.0

35.0

56.0

70.0

Nominal air flow evaporating (m3/h)

1530

2550

4075

5100

7725

10200

Plenum discharge fan motor rating (kW)

0.37

0.55

1.10

1.50

2.12

3.00

Compressor motor power (kW)

3.55

5.48

9.79

10.94

19.58

21.88

Nominal condensing load (kW)

14.42

21.42

33.24

47.44

77.78

94.88

Nominal air-flow condensing (m3/h)

6624

9360

14400

21600

28080

37440

Condenser fan motor rating (kW)

2 @ 0.37

2 @ 0.55

2 @ 0.75

3 @ 0.58

3 @ 0.75

4 @ 0.75

1 x 4.5

2 x 4.5

2 x 9.0

2 x 9.0

3 x 9.0

4 x 9.0

Electric heating (optional) (kW)

W

TRA20

D

P

TRA05

H

TRA03

Dimensions

H (mm)

1300

1600

1800

1800

2000

2100

W (mm)

900

900

1200

1250

1400

1800

D (mm)

450

550

650

650

850

850

P (mm)

120

180

230

230

300

330

178

219

284

328

501

594

Weight (kg)

H

Internal section

External section Dimensions

H (mm)

1380

1400

1420

1400

1420

1420

W (mm)

1200

1400

1700

2400

2600

3200

D (mm)

700

800

900

900

1100

1100

154

200

253

290

409

Weight (kg)

W

D

528

Nominal duties are based on air entering @ 35 C Cdb @ 50% RH utilising R407c with ambient air @ 40 C 0

0

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 5

5


KW SELF-CONTAINED MARINE AIR CONDITIONING UNIT • • • • • • • •

Nominal cooling loads: 10.0 kW - 25.0 kW Fresh-water-cooled through plate heat exchanger Refrigerant R404C / R449A / R448A Spigoted duct connection Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) Removable front panel for access and maintenance Quick-release grille for air filter cleaning and replacement Units supplied factory pre-charged only requiring suitable water and electrical connections • Electrical supply - 380V 3ph 50Hz - 440V 3ph 60Hz • Available options - Sea-water-cooled through coaxial condenser - Fresh-air connection - Color to suit operating environment - Plenum and grille discharge - Electric or hot-water heating - Fan pressure to suit application - Refrigerant R134a or R404A W

KW20

10

15

20

25

1500

2200

2950

3700

Fan motor rating (kW)

0.37

0.55

0.75

1.1

Compressor motor power (kW)

4.34

4.50

4.90

6.48

Nominal fresh-water quantity (m3/h)

2.41

3.45

4.56

6.01

Dimensions

H (mm)

1500

1700

1950

1950

W (mm)

550

700

700

800

D (mm)

550

750

750

750

P (mm)

150

200

225

245

186

234

282

309

1 x 4.5

2 x 4.5

2 x 6.0

2 x 9.0

Weight (kg) Electric heating (optional) (kW)

D

KW25 P

Nominal cooling load (kW) Nominal air flow (m3/h)

KW15

H

KW10

Nominal duties are based on air entering @ 250C Cdb @ 50% RH utilising R407c with fresh water @ 360C

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 6

6


KWA AIR-COOLED MARINE AIR CONDITIONING UNIT • • • •

Nominal cooling loads: 10.0 kW - 30.0 kW Air-cooled Refrigerant R407C Internal section - Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) - Removable panels for access and maintenance - Quick-release grille for air filter cleaning and replacement • External section - Electro-coated mild-steel with powder-coated paint finish RAL 9018 (grey) - Condenser coil with Cu tubes and Cu fins • Electrical supply - 380V 3ph 50Hz - 440V 3ph 60Hz • Available options - Sea-water-cooled through coaxial condenser - Fresh-air connection - Color to suit operating environment - Electric heating - Fan pressure to suit application - Refrigerant R134a KWA10 Nominal cooling load (kW)

KWA15

KWA20

KWA25

KWA30

10

15

20

25

30

Nominal air flow (evaporating) (m3/h)

1500

2200

2950

3700

4800

Plenum discharge fan motor rating (kW)

0.37

0.55

0.55

1.10

1.10

Compressor motor power (kW)

3.55

5.48

5.48

9.79

9.79

Nominal condensing load (kW)

13.92

21.03

26.03

33.24

33.24

Nominal air flow (condensing) (m3/h)

6624

8022

10670

14400

14400

Condenser fan motor rating (kW)

2 @ 0.37

2 @ 0.55

2 @ 0.55

2 @ 0.75

2 @ 0.75

1 x 4.5

2 x 4.5

2 x 6.0

2 x 9.0

2 x 9.0

Electric heating (optional) (kW)

Internal section Dimensions

H (mm)

1500

1700

1950

1950

1950

W (mm)

550

700

700

800

1000

D (mm)

550

750

750

750

750

P (mm)

150

200

225

245

270

186

234

273

308

350

Weight (kg)

External section Dimensions

H (mm)

1380

1400

1400

1420

1420

W (mm)

1200

1400

1400

1700

1700

D (mm)

700

800

800

900

900

154

200

200

250

250

Weight (kg)

Nominal duties are based on air entering @ 350C Cdb @ 50% RH utilising R407c with ambient air @ 400C D

H

H

P

W

W

7

D

7


ACC (H&V) MARINE AIR-COOLED CONDENSER • Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) • Condenser coil with Cu and Cu fins • Refrigerant R407c • Electrical supply - 380V 3ph 50Hz - 440V 3ph 60Hz • Available options - Stainless-steel 316 casing - Protective coating to coil - Atex II 2 G Eex IIB T4 for hazardous areas - Refrigerant R134a ACCV5

ACCV8

ACCV10

ACCV15

15.00

22.00

34.00

48.00

78.00

ACCV20 95.00

Nominal air flow (m³/h)

6624

9360

14400

21600

28080

37440

Fan motor rating (total) (kW)

2 @ 0.37

2 @ 0.55

2 @ 0.75

3 @ 0.58

3 @ 0.75

4 @ 0.75

Dimensions (Vertical) H (mm)

1380

1400

1420

1400

1420

1420

W (mm)

1200

1400

1700

2400

2600

3200

D (mm)

700

800

900

900

1100

1100

154

200

253

290

409

528

ACCH20

Unit weight (kg)

H

ACCV3 Nominal condensing load (kW)

W

D

Nominal duties are based on ambient air @ 400C

ACCH5

ACCH8

ACCH10

ACCH15

15.00

22.00

34.00

48.00

78.00

95.00

Nominal air flow (m³/h)

6624

9360

14400

21600

28080

37440

Fan motor rating (total) (kW)

2 @ 0.37

2 @ 0.55

2 @ 0.75

3 @ 0.58

3 @ 0.75

4 @ 0.75

Dimensions (Vertical) H (mm)

900

1000

1100

1100

1300

1300

W (mm)

1200

1400

1700

2000

2600

3200

D (mm)

700

700

700

700

700

700

174

216

287

330

449

558

Unit weight (kg)

W

D

H

ACCH3 Nominal condensing load (kW)

Nominal duties are based on ambient air @ 40 C 0

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 8

8


FP AIR-COOLED HAZARDOUS AREA AIR CONDITIONING UNIT

• • • •

Nominal cooling loads: 3.5 kW / 5.25 kW / 7.0 kW Air-cooled Refrigerant R407c / R449A / R448A A60-class fire-resistant division between internal and external section Internal section - Suitable for non-hazardous area - Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) External section - ATEX II 2 G EEx d IIB T4 suitable for hazardous area - Cu/Cu condenser coil - Stainless-steel 316 casing with powder-coated paint finish RAL 9018 (grey) Removable top and side panels for access and maintenance Quick-release grille for air filter cleaning and replacement Units supplied factory pre-charged Electrical supply - 220V 1ph 50/60Hz - 380V 3ph 50Hz - 440V 3ph 60Hz Available options - Color to suit operating environment - Split system version - Electric heating - Refrigerant R134a FP12

FP18

FP24

Nominal cooling load (kW)

3.50

5.25

7.00

Nominal air flow - low (m3/h) - high (m3/h)

400 500

500 675

800 1000

Evaporator Fan motor rating (kW) Compressor motor power (kW) 480

0.037

Condenser fan motor ratingINTERNAL (kW) SECTION Dimensions H (mm)

0.18

W (mm)

1.87 450

0.045 460 2.28 0.25 EXTERNAL SECTION 550

480

460

INTERNAL SECTION

EXTERNAL SECTION

0.074 W

2.89 2@0.18 550

760

760

1060

Weight (kg)

125

135

195

Electric heating (optional) (kW)

1.5

1.5

3.0

Nominal duties are based on air entering @ 250C Cdb @ 50% RH utilising R407c with ambient air @ 400C

H

• • • •

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 9

9


KWG GALLEY SELF-CONTAINED AIR CONDITIONING UNIT • • • • • • • •

Unit designed to meet SOLAS requirements Nominal cooling loads: 10.0 kW / 25.0 kW Fresh-water-cooled through plate heat exchanger Refrigerant R407C / R449A / R448A Ducted, filtered rear inlet and vertical discharge Electro-coated mild-steel casing with powder-coated paint finish RAL 9018 (grey) Removable panels for access and maintenance Units supplied factory pre-charged only requiring suitable water and electrical connections • Electric heating • Electrical supply - 380V 3ph 50Hz - 440V 3ph 60Hz • Available options - Stainless-steel 316 casing with powder-coated paint finish - Color to suit operating environment - Alternative fan pressures - Split system version - Hot-water heating - Refrigerant: R134a or R404A - Sea-water-cooled through coaxial condenser W

KWG15

KWG20

KWG25

Nominal cooling load (kW)

10.0

15.0

20

25

Nominal heating load (kW)

9.0

12.0

13.5

18.0 1550

Nominal air flow (m3/h)

600

700

1100

External pressure (kW)

600

600

600

600

Fan motor rating (kW)

0.37

0.37

0.55

0.75

Compressor motor power (kW)

3.55

4.72

6.45

9.79

Nominal water quantity (m3/h)

1.08

1.56

3.12

3.70

Dimensions

Weight (kg)

H (mm)

1500

1750

1750

1750

W (mm)

550

700

700

700

D (mm)

550

750

750

750

230

320

340

370

H

KWG10

D

Nominal duties are based on 100% fresh air entering @ 350C Cdb @ 70% RH (summer) and -250C (winter) utilising R407c with fresh water @ 360C

Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 10

10


Heinen & Hopman encourages a more sustainable world. By providing eco-friendly solutions and services we offer our clients the option of reducing energy consumption and thus CO2 emissions.

you require more information “ Do about our products or do you

require advice? I am keen to help you further!

Paul Spoorenberg

-

Sales Manager sales@heinenhopman.com

OUTSIDE HUMIDITY

35°C 45°C

90% 40%

22º C

Inside

PROVIDED BY HEINEN & HOPMAN

www.heinenhopman.com 11

Heating

Ventilation

Air Conditioning

Refrigeration

11


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.