UNIT HEATER Products
OUTSIDE HUMIDITY
35°C 45°C
90% 40%
22º C
Inside
PROVIDED BY HEINEN & HOPMAN
1
Unit Heaters- HEINEN & HOPMAN 2020 ©
Heating
Ventilation
Air Conditioning
Unit Heaters - HEINEN & HOPMAN 2020 ©
Refrigeration
1
COMPANY INTRODUCTION Heinen & Hopman is a reliable partner in the global maritime sector, offering top quality products and service in the field of climate control (HVAC & Refrigeration). The no-nonsense and entrepreneurial character of the founders who established the company in 1965 is still one of the main cornerstones of Heinen & Hopman. We support our clients using our knowledge and experience by realising the best possible climate control solutions; either fully customised or with varying degrees of standardisation. Like our clients, we are continuously active on a global scale to ensure that we can always be of service. We are also constantly searching for sustainable innovations as we aim for the best and very latest solutions in collaboration with our clients. Heinen & Hopman is critically aware that a company’s greatest asset is its employees – it is they who represent the added value of our business. Our goal is to continue to expand in the global market for maritime climate control solutions in a future-proof way. In short, you can rely on Heinen & Hopman to deploy the know-how and expertise required to solve any heating, ventilation, air conditioning and refrigeration issue onboard ships. We see complexity as a challenge, no matter where your vessel may be.
OPERATING GLOBALLY Global networking is crucial in every line of business and the shipping industry is certainly no exception. Being able to offer the highest quality of service and products to our clients at all times and in all places is of enormous importance to us. This is why Heinen & Hopman aims to keep expanding our network and know-how and ensure we are exactly where our clients need us to be.
Europe 22 Offices
1200 Employees
4
Factories
11
Countries
Americas 11 Offices
1
Unit Heaters- HEINEN & HOPMAN 2020 ©
220 Employees
3
Countries
3
Factories
Asia 10 Offices
380 Employees
7
Factories
7
Countries
Unit Heaters - HEINEN & HOPMAN 2020 ©
1
INTRODUCTION Unit heaters The unit heaters are primary used to heat large spaces outside the accommodation like workshops, engine room, etc. The heating is done by hot-air supply through a heating coil. There are different types of heating units: • Electrical heating unit: VLE heating units are mainly used in rough environments where boiler water is not available. The heating units are available from 3 kW to 36 kW. • Explosion-proof electrical heating unit: FE2 heating units are ATEX certified unit heaters, specially developed for Ex II and EX IIB zone. The heating units are available from 2.5 kW to 23.1 kW. • Hot-water heating unit: TGA heating units are the most common heating units used offshore and on board ships. The hot water from the boiler acts as heating medium. Steam can also be used as heating medium for higher efficiency. The heating units are available from 8.1 kW to 100 kW. • Thermal-oil heating unit: Thermal-oil heating units are functionally similar to hot-water heating units. The heating units are mainly used in areas with extremely low temperatures. Thermal oil acts as heating medium. Thermal oil has a low freezing point and a high temperature limit up to 400 °C. • Portable heating unit: Delta electrical heating units are easily movable and can be mounted to the wall with brackets for permanent installation. The heating units are available from 3 kW to 21 kW.
2
Unit Heaters- HEINEN & HOPMAN 2020 ©
Unit Heaters - HEINEN & HOPMAN 2020 ©
2
VLE UNIT HEATERS The VLE electrical fan heaters are designed for rough environments e.g. on ships, offshore, in workshops and large production areas. The heaters are available in three standard types: VLE-4, VLE-5 and VLE-6. The heaters are available in galvanized steel, but can also be supplied in different materials (on customer request). The heaters have a built-in thermostat (0-40 °C) which ensures optimal operation and minimizes the energy consumption. The heaters have a thermal fuse that turns off the heater at 110 °C. Heating element The heaters have an electric tube heating element made of stainless steel (AISI304). Standard version The heaters are supplied in 3 x 440V (AC) or 3 x 400V (AC), but very often applications require different voltages. All types are available from 230V to 3 x 690V, with output from 1.2 kW to 150 kW. Safety class IP44. Installation The heaters can be mounted on the wall or ceiling (horizontally or vertically). Capacity
VLE - 5
VLE - 4 Range
1.2 kW ~ 12.5 kW
Range
16.5 kW ~ 25 kW
Power
3ph / 440V / 60Hz 3ph / 400V / 50Hz (3 kW available in 230 V)
Power
3ph / 440V / 60Hz 3ph / 400V / 50Hz
Dimension
610 x 460 x 560 (mm)
Air quantity
1440 m /h
Sound level
75dB(A)
3
Dimension Air quantity Sound level
710 x 660 x 670 (mm) 2520 m3/h 75dB(A)
VLE - 6 Range
30.5 kW ~ 36 kW
Power
3ph / 440V / 60Hz 3ph / 400V / 50Hz
Dimension
910 x 660 x 760 (mm)
Air quantity
3960 m3/h
Sound level
75dB(A)
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 3
Unit Heaters- HEINEN & HOPMAN 2020 ©
Unit Heaters - HEINEN & HOPMAN 2020 ©
3
FE2 UNIT HEATERS FE2 electrical fan heaters are CE-marked & ATEX-approved for use in hazardous areas. The heaters are designed for locations where specific explosive gases or dust may be present. The heaters use the Vacucore. The induced vacuum within the sealed core provides greater efficiency, distribution of heat across the face of the exchanger and a faster warm-up. If necessary, the entire core can be safely and easily replaced with a new exchanger or core. The heaters are ATEX Approved (directive 94/9/EC) and Ex II 2 G, Ex d IIB T3 Gb-certified. Heating element The heater core assembly has a sturdy, epoxy-coated, 14-gauge steel cabinet which carries the motor and fan assembly. Adjustable louvers allow directional control of the air flow. All fasteners are zinc-plated for corrosion protection. Standard version The heaters are supplied in 50 Hz or 60 Hz. All types are available from 1 x 220V to 3 x 440V. Installation The heaters can be mounted on the wall or ceiling (horizontally or vertically). Mounting kits are available on request. Mounting kits are made of steel with a wet-applied enamel paint. If the heater is installed on a structure that must be transported, provide additional support for the heater during transport. The suspended weight must not exceed 300 lbs (136 kg).
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 4
Unit Heaters- HEINEN & HOPMAN 2020 ©
Unit Heaters - HEINEN & HOPMAN 2020 ©
4
SPECIFICATION FOR 50 HZ MODELS Voltage
Nominal wattage
Phase
FE2-220150-025 FE2-220150-042 FE2-220150-063 FE2-220150-084 FE2-220150-126
220 V 220 V 220 V 220 V 220 V
2.5 kW 4.2 kW 6.3 kW 8.4 kW 12.6 kW
1 1 1 1 1
FE2-230150-028 FE2-230150-046 FE2-230150-069 FE2-230150-138
230 V 230 V 230 V 230 V
2.8 kW 4.6 kW 6.9 kW 13.8 kW
1 1 1 1
FE2-240150-030 FE2-240150-050 FE2-240150-075 FE2-240150-100 FE2-240150-150
240 V 240 V 240 V 240 V 240 V
3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW
1 1 1 1 1
FE2-380350-025 FE2-380350-042 FE2-380350-063 FE2-380350-084 FE2-380350-125 FE2-380350-167 FE2-380350-209
380 V 380 V 380 V 380 V 380 V 380 V 380 V
2.5 kW 4.2 kW 6.3 kW 8.4 kW 12.5 kW 16.7 kW 20.9 kW
3 3 3 3 3 3 3
FE2-400350-028 FE2-400350-046 FE2-400350-069 FE2-400350-093 FE2-400350-139 FE2-400350-185 FE2-400350-231
400 V 400 V 400 V 400 V 400 V 400 V 400 V
2.8 kW 4.6 kW 6.9 kW 9.3 kW 13.9 kW 18.5 kW 23.1 kW
3 3 3 3 3 3 3
FE2-415350-037 FE2-415350-075 FE2-415350-149 FE2-415350-224
415 V 415 V 415 V 415 V
3.7 kW 7.5 kW 14.9 kW 22.4 kW
3 3 3 3
FE2-440350-042 FE2-440350-084 FE2-440350-168 FE2-440350-210
440 V 440 V 440 V 440 V
4.2 kW 8.4 kW 16.8 kW 21.0 kW
3 3 3 3
Model
SPECIFICATION FOR 60 HZ MODELS Voltage
Nominal wattage
Phase
FE2-220160-025 FE2-220160-042 FE2-220160-063 FE2-220160-084 FE2-220160-126
220 V 220 V 220 V 220 V 220 V
2.5 kW 4.2 kW 6.3 kW 8.4 kW 12.6 kW
1 1 1 1 1
FE2-230160-028 FE2-230160-046 FE2-230160-069 FE2-230160-092 FE2-230160-138
230 V 230 V 230 V 230 V 230 V
2.8 kW 4.6 kW 6.9 kW 9.2 kW 13.8 kW
1 1 1 1 1
FE2-240160-030 FE2-240160-050 FE2-240160-075 FE2-240160-100 FE2-240160-150
240 V 240 V 240 V 240 V 240 V
3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW
1 1 1 1 1
FE2-440360-042 FE2-440360-084 FE2-440360-168 FE2-440360-210
440 V 440 V 440 V 440 V
4.2 kW 8.4 kW 16.8 kW 21.0 kW
3 3 3 3
FE2-480360-030 FE2-440360-050 FE2-440360-075 FE2-440360-100 FE2-440360-150 FE2-440360-200
480 V 480 V 480 V 480 V 480 V 480 V
3.0 kW 5.0 kW 7.5 kW 10.0 kW 15.0 kW 20.0 kW
3 3 3 3 3 3
Model
Alternatives available on request. Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.
Don’t hesitate to contact us for more information about our service options. We are eager to explain the possibilities for your vessel or structure. Scan the QR-code or visit heinenhopman.com 5
Unit Heaters- HEINEN & HOPMAN 2020 ©
Unit Heaters - HEINEN & HOPMAN 2020 ©
5
HOT-WATER UNIT HEATERS Hot-water unit heaters are primarily designed for heating of large rooms, workshops or production areas. The TGA 2000 heaters are designed for onshore and offshore objects. The heaters are manufactured in different sizes, with a heating capacity from 8.1 kW to 100 kW and an air flow from 1430 m³/h to 9370 m³/h. Heating element The heaters use the boiler water as heating medium. The air will flow through the heating coil by using a axial or centrifugal fan. The heaters are available with copper tube and aluminum fins, but can also be supplied with stainless-steel casing and galvanized-steel heat exchanger (suitable for rough environments e.g. on ships, offshore). Steam can also be used as heating medium for higher efficiency. The TGA 3000 heaters have a robust steel hot-dip galvanized heating coil, designed for steam heating. For extremely low temperatures where water/glycol is not applicable, thermal oil can act as heating medium. The TGA 1000 heaters have a robust steel hot-dip galvanized heat exchanger, designed for use with hot water, overheated water or thermal oil. More information on steam and thermal oil heaters on request. Standard version The heaters have 2-speed motor ventilators. The motors have an externally rotating rotor. • Protection class: IP54 • Insulation class: F On request, special motors, e.g. 3-speed motors, EEx(e) or EEx(d) motors can be mounted. The heaters are available in 1 x 230V, 3 x 230V or 3 x 400V (2-speed or 3-speed). Installation The TGA can be mounted on the wall or ceiling (horizontally or vertically). Options • Double-sided air grid • Four-sided air grid • Drain (when used for cooling) • 2-speed switch • 5-step switch • Ceiling mounting kit • Wall mounting kit TGA type
6
Capacity kW (15°C, 70-90°C)
Air quantity m3/h
A mm
B mm
C mm
2300
8,1 - 18,2
1160-1430
450
355
450
2400
11,8 - 27,4
1860-2290
500
395
500
2500
19,1 - 45,5
3250-3850
600
425
600
2600
28,2 - 65,1
4460-5690
700
425
700
2700
41,9 - 100
7450-9370
800
425
800
Unit Heaters- HEINEN & HOPMAN 2020 ©
Unit Heaters - HEINEN & HOPMAN 2020 ©
6
Austria T: +43 1720 1309 E: info@drewsmarine.com Brazil T: +55 213 587 4241/4244 E: info@br.heinenhopman.com Canada T:+1 450 659 6571 E: info@bronswerkgroup.com Denmark T: +45 5164 1614 E: admin@teknotherm.no France - La Ciotat T: +33 4 4204 8685 E: info@heinenhopmanfrance.com France - Antibes T: +33 4 8902 4562 E: info@heinenhopmanfrance.com Germany T:+49 4073 1680 E: info@drewsmarine.com Germany T:+49 471 9869 300 E: info@moehringms.com
India T: +91 336 499 1293 E: info@heinenhopmanindia.com Italy T: +39 187 187 8500 E: info@it.heinenhopman.com The Netherlands (HQ) T: +31 33 299 2500 E: info@heinenhopman.com The Netherlands - Rotterdam T: +31 18 020 9210 E: binnenvaart@heinenhopman.nl Norway T: +47 6919 0900 E: admin@teknotherm.no Peoples Republic of China T: +86 213 253 2896 E: info@cn.heinenhopman.com Peoples Republic of China T: +86 510 8528 1763 E: admin@teknotherm.no Poland T: +48 914 331 800 E: admin@teknotherm.no
Heinen & Hopman encourages a more sustainable world. By providing eco-friendly solutions and services we offer our clients the option of reducing energy consumption and thus CO2 emissions.
Romania T: +40 236 448 222 E: office@ro.heinenhopman.com Russia T: +7 812 449 3535 E: info@heinenhopman.ru Singapore T: +65 6897 7879 E: info@sg.heinenhopman.com South Korea T: +82 704 901 0000 E: info@kr.heinenhopman.com Spain T: +34 932 259 668 E: info@es.heinenhopman.com Sweden T: +46 3121 7500 E: admin@teknotherm.no Turkey T: +90 216 493 8118 E: info@tr.heinenhopman.com UAE - Abu Dhabi T:+971 2550 4147 E: info@caspuae.com
UAE - Dubai T: +971 4263 5453 E: info@caspuae.com USA - Seattle, Washington T: +1 206 632 7883 E: sales.uk@teknotherm.com USA - Fort Lauderdale, Florida T: +1 954 463 0110 E: info@arwmaritime.com USA - Houma, Louisiana T: +1 985 876 7982 E: leblanc@leblancandassociates.com
you require more information “ Do about our products or do you
“
require advice? I am keen to help you further!
Eric Stoffelsen
-
Sales Manager sales@heinenhopman.com
OUTSIDE HUMIDITY
35°C 45°C
90% 40%
22º C
Inside
PROVIDED BY HEINEN & HOPMAN
www.heinenhopman.com 7
Unit Heaters- HEINEN & HOPMAN 2020 ©
Heating
Ventilation
Air Conditioning
Unit Heaters - HEINEN & HOPMAN 2020 ©
Refrigeration
7