DeltaMax DeviceNet [IB-19B005]

Page 12

INDUSTRIAL INDEXING SYSTEMS, Inc. DELTAMAX DEVICENET

IB-19B005 USER’S GUIDE

Table 1 - Addressing Modes ( attribute 4 ) Value 0 1 2

Description Address offset is obtained from service data. Address is obtained from the address offset attribute, the attribute is not incremented after the access. Address is obtained from the address offset attribute, with auto-increment, in that the address offset is incremented after the access by the “Data Length”. Once the address reaches the end offset a Vendor Specific error is returned with add code of 01 (address offset out of range).

Data Memory Behavior Attributes 5 and 6 are defaulted such that over DeviceNet MacroProgram variables may not be written to. If it is required that variables in a MacroProgram be written to over the Network then a dnet_range instruction must be executed in the MacroProgram, see dnet_range section herein.

JANUARY 1998