DeltaMax DeviceNet [IB-19B005]

Page 8

INDUSTRIAL INDEXING SYSTEMS, Inc. DELTAMAX DEVICENET

IB-19B005 USER’S GUIDE

DELTAMAX OBJECTS

FLAGS DeviceNet has limited access to DeltaMax FLAG bit map memory. FLAG memory in a DeltaMax contains vital information for the programmer developing a MacroProgram for any application. This bitmap is broken down as follows:

flag #

description

0-15

Discrete Inputs; Application specific, user programmable, originate from an external connector. Discrete Outputs; Application specific, user programmable, output to an external connector. Software programmable limit switches. DeviceNet input flags. The DeviceNet port may read/write to these flags. To be considered as inputs only by a MacroProgrammer, therefore not write-able by a MacroProgram. DeviceNet output flags. The DeviceNet port may only read these flags. To be considered as outputs from the MacroProgram, they may be written too or read from in a MacroProgram. Timers Axis1 status flags; example JOGGING,BUSY,DOWN,INDEXING, ect.. Pseudo Axis status flags, similar to Axis1 status flags, however this is a software axis Analog status flags. DeviceNet Status flags; status flags read only. The DeviceNet port may only read these flags. Not Used User flags; have programmable effects in motion program.

16-23 24-31 32-55

56-71

72-79 80-95 96-111 112-127 128-132 133-207 208-255