chainflex data cables

Page 1

EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 110

v max. [m/s] gliding

a max. [m/s2]

Page

-5/ +70

3

2

20

112

CF240.PUR

PUR

10-12

-20/ +80

3

2

20

114 *

Oil-resistant

10-12

Temperature moved from/to [°C]

Shield

PVC

Jacket

CF240

chainflex® cable

v max. [m/s] unsupported

Approvals and standards

Minimum bending radius, moved [factor x d]

chainflex type

Torsion resistant

®

Coaxial cables

Data cables

Data cables – Stranded in layers

Data cables – Twisted pair CF211

PVC

7,5

-5/ +70

5

3

50

116

CF113

PUR

10

-20/ +80

10

5

80

118

CF11

TPE

6,8

-35/ +100

10

6

100

120

Data cables – Twisted pair/Pair shield CF112

PUR

10

-20/ +80

10

5

80

122

CF12

TPE

10

-35/ +100

10

6

100

124

-20/ +80

2

1

20

-35/ +100

10

5

100

Data cables – Thermo (Chapter "Special cables" CF THERMO

PUR

✔ 12,5-15

256)

Data cables – Coax CF KOAX 1

TPE

10

128

111


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 112

CF240 PVC 10-12 x d

PVC Data cable CF240 ● ● ● ● ●

Class 4.2.2 (4 medium load requirements

for medium load requirements PVC outer jacket shielded oil-resistant flame-retardant

Conductor Core insulation Core stranding Core identification

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. The individual cores are stranded in layers with short pitch lengths. Colour code in accordance with DIN 47100.

Intermediate jacket Foil taping over the external layer. Overall shield Outer jacket

T/R moved

T/R fixed

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 10 x d with < 10 m travel distance, minimum bending radius 12 x d with ≥ 10 m travel distance. -20 °C to +70 °C, minimum bending radius 5 x d

Image exemplary.

v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2 Travel distance

Freely suspended and gliding travel distances up to 50 m, Class 2

Nominal voltage

300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

eplan download, configurator

www.igus.eu/en/CF240

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

2 travel distance up to 50 m 2 oil-resistant)

CF240 PVC 10-12 x d

UL/CSA

Style 10493 and 2464, 300 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

Typical application area ● ● ● ● ●

for medium load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 50 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes

Delivery program Part No. CF240.01.03 CF240.01.04 CF240.01.05 CF240.01.07 CF240.01.14 CF240.01.18 CF240.01.24 CF240.02.03 CF240.02.04 CF240.02.05 CF240.02.07 CF240.02.08 CF240.02.14 CF240.02.18 CF240.02.24 CF240.03.03 CF240.03.04 CF240.03.05 CF240.03.07 CF240.03.10 CF240.03.14 CF240.03.18 CF240.03.24

Number of cores and conductor nominal cross section [mm2] (3 x 0,14)C (4 x 0,14)C (5 x 0,14)C (7 x 0,14)C (14 x 0,14)C (18 x 0,14)C (24 x 0,14)C (3 x 0,25)C (4 x 0,25)C (5 x 0,25)C (7 x 0,25)C (8 x 0,25)C (14 x 0,25)C (18 x 0,25)C (24 x 0,25)C (3 x 0,34)C (4 x 0,34)C (5 x 0,34)C (7 x 0,34)C (10 x 0,34)C (14 x 0,34)C (18 x 0,34)C (24 x 0,34)C

External diameter approx. [mm] 4,5 5,0 5,5 6,0 7,0 8,0 9,5 5,5 5,5 6,0 7,0 7,5 8,0 9,0 11,0 5,5 6,0 6,5 7,0 8,5 8,5 10,0 12,0

Copper index [kg/km] 16 18 20 25 42 48 60 21 24 27 35 40 57 71 92 24 28 32 43 55 71 87 115

Weight [kg/km] 35 38 42 51 76 90 113 40 48 52 66 74 100 122 174 45 51 58 75 110 116 140 203

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

113


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 114

CF240.PUR PUR 10-12 x d

PUR Data cable CF240.PUR ● ● ● ● ● ● ● ●

Class 5.2.3 (5 high load requirements

for high load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Core identification

Silicon-free

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. The individual cores are stranded in layers with short pitch lengths. Colour code in accordance with DIN 47100

2 travel distance up to 50 m 3 oil-resistant)

CF240.PUR PUR 10-12 x d

Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

UL/CSA

Style 10493 and 20233, 300 V, 80°C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Intermediate jacket Foil taping over the external layer

Typical application area Overall shield Outer jacket

T/R moved T/R fixed

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Silver gray (similar to RAL 7001) -20 °C to +80 °C, minimum bending radius 10 x d with < 10 m travel distance, minimum bending radius 12 x d with ≥ 10 m travel distance -40 °C to +80 °C, minimum bending radius 5 x d

v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2

Image exemplary.

Travel distance UV-resistant

Freely suspended and gliding travel distances up to 50 m, Class 2. Medium

Nominal voltage

300/300 V (following DIN VDE 0245)

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

eplan download, configurator

www.igus.eu/en/CF240PUR

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

● ● ● ● ●

for high load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 50 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

Delivery program Part No. CF240.PUR.01.03(1) CF240.PUR.01.04 CF240.PUR.01.05(1) CF240.PUR.01.07(1) CF240.PUR.01.14 CF240.PUR.01.18(1) CF240.PUR.02.03 CF240.PUR.02.04 CF240.PUR.02.05 CF240.PUR.02.07 CF240.PUR.02.08 CF240.PUR.02.14 CF240.PUR.02.18 CF240.PUR.03.03(1) CF240.PUR.03.04 CF240.PUR.03.05(1) CF240.PUR.03.07 CF240.PUR.03.14(1) CF240.PUR.03.18(1)

Number of cores and conductor nominal cross section [mm2] (3 x 0,14)C (4 x 0,14)C (5 x 0,14)C (7 x 0,14)C (14 x 0,14)C (18 x 0,14)C (3 x 0,25)C (4 x 0,25)C (5 x 0,25)C (7 x 0,25)C (8 x 0,25)C (14 x 0,25)C (18 x 0,25)C (3 x 0,34)C (4 x 0,34)C (5 x 0,34)C (7 x 0,34)C (14 x 0,34)C (18 x 0,34)C

External diameter approx. [mm] 5,5 6,0 6,5 7,0 8,0 8,5 6,0 6,0 6,5 7,0 7,5 8,0 9,0 6,0 6,5 7,0 8,0 9,5 10,0

Copper index [kg/km] 16 18 20 25 42 48 21 24 27 35 40 57 71 24 28 32 43 71 88

Weight [kg/km] 35 38 43 52 77 92 40 44 49 63 69 100 119 46 52 58 82 123 152

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

115


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 116

CF211 PVC 7,5 x d

PVC Data cable CF211 ● ● ● ● ● ●

Class 5.3.2 (5 high load requirements

for high load requirements PVC outer jacket shielded twisted-pair oil-resistant flame-retardant

Conductor Core insulation Core stranding Core identification

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100.

Intermediate jacket Foil taping over the external layer. Overall shield Outer jacket

T/R moved

T/R fixed

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 7,5 x d. Following an extensive series of tests, the bending radius of CF211 has been reduced from 10 x d to 7,5 x d. -20 °C to +70 °C, minimum bending radius 5 x d

v max. 5 m/s, 3 m/s unsupported/gliding a max. 50 m/s2 Travel distance Nominal voltage

Freely suspended and gliding travel distances up to 100 m, Class 3 300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10493 and 2464, 300 V, 80 °C

Image exemplary.

UL/CSA

eplan download, configurator

www.igus.eu/en/CF211

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

3 travel distance up to 100 m 2 oil-resistant)

CF211 PVC 7,5 x d

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

Typical application area ● ● ● ● ●

for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes

Delivery program Part No. CF211.02.01.02 CF211.02.02.02(2) CF211.02.03.02 CF211.02.04.02 CF211.02.05.02 CF211.02.06.02 CF211.02.08.02 CF211.02.10.02 CF211.02.14.02 CF211.03.03.02 CF211.03.08.02 CF211.03.10.02(1) CF211.05.01.02 CF211.05.02.02(2) CF211.05.03.02 CF211.05.04.02 CF211.05.05.02 CF211.05.06.02 CF211.05.08.02 CF211.05.10.02 CF211.05.14.02

Number of cores and conductor nominal cross section [mm2] (1 x (2 x 0,25))C (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (8 x (2 x 0,25))C (10 x (2 x 0,25))C (14 x (2 x 0,25))C (3 x (2 x 0,34))C (8 x (2 x 0,34))C (10 x (2 x 0,34))C (1 x (2 x 0,5))C (2 x (2 x 0,5))C (3 x (2 x 0,5))C (4 x (2 x 0,5))C (5 x (2 x 0,5))C (6 x (2 x 0,5))C (8 x (2 x 0,5))C (10 x (2 x 0,5))C (14 x (2 x 0,5))C

External diameter approx. [mm] 5,0 5,5 7,0 8,0 8,5 9,5 11,5 13,0 13,5 8,0 12,0 12,0 5,5 8,5 9,0 9,5 11,0 12,5 14,5 16,0 17,0

Copper index [kg/km] 16 28 37 44 51 58 75 93 109 37 98 118 23 44 57 68 80 99 124 175 187

Weight [kg/km] 35 60 73 85 97 110 160 195 205 79 202 254 50 80 100 120 145 185 230 320 335

(1) Delivery time upon inquiry. The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Measuring system cables Page 164, CF211 (PVC) Page 170, CF111.D (TPE) Page 180, CF11.D (TPE)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

117


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 118

CF113 PUR 10 x d

PUR Data cable CF113 ● ● ● ● ● ● ● ●

Class 6.3.3 (6 maximum load requirements

for maximum load requirements PUR outer jacket shielded, twisted-pair oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Core identification

Silicon-free

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality TPE mixture.

3 travel distance up to 100 m 3 oil-resistant)

Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

UL/CSA

Style 10493 and 20233, 300 V, 80°C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

CF113 PUR 10 x d

2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100

Typical application area Intermediate jacket PUR mixture adapted to suit the requirements in energy chains . ®

Overall shield Outer jacket

T/R moved T/R fixed

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016) -20 °C to +80 °C, minimum bending radius 10 x d -40 °C to +80 °C, minimum bending radius 5 x d

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 High

Nominal voltage

300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

.

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (8 x (2 x 0,25))C (2 x (2 x 0,5))C (3 x (2 x 0,5))C (4 x (2 x 0,5))C (5 x (2 x 0,5))C (6 x (2 x 0,5))C

CF113.02.02.02(2) CF113.02.03.02 CF113.02.04.02 CF113.02.05.02 CF113.02.06.02 CF113.02.08.02 New* CF113.05.02.02(2) CF113.05.03.02(1) CF113.05.04.02 CF113.05.05.02(1) CF113.05.06.02

External diameter approx. [mm] 8,0 8,5 9,0 9,5 10,0 11,5 10,0 10,5 11,0 11,5 12,5

Copper index [kg/km] 31 40 45 56 62 81 50 62 70 84 95

Weight [kg/km] 86 96 107 125 137 176 127 142 162 185 207

(1) Delivery time upon inquiry The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Order example: CF113.02.06.02 – in your desired length (0,5 m steps) CF113 chainflex series .02 Code nominal cross section .06 Number of pairs .02 Identification pairs ®

Please use www.chainflex.eu/en/CF113 for your online order.

Image exemplary.

Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CF113

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

119


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 120

CF11 TPE 6,8 x d

TPE Data cable CF11 ● ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

for maximum load requirements TPE outer jacket shielded twisted-pair oil-resistant, biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant

Conductor Core insulation Core stranding Core identification Inner jacket Overall shield Outer jacket

T/R moved

T/R fixed

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Cores < 1,0 mm2: Colour code in accordance with DIN 47100 Cores ≥ 1,0 mm2: Cores black with white numerals TPE mixture adapted to suit the requirements in energy chains®. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 6,8 x d. Following an extensive series of tests, the bending radius of CF11 has been reduced from 10 x d to 6,8 x d. -40 °C to +100 °C, minimum bending radius 5 x d

v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m and more, Class 4 High

Nominal voltage

300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).

Image exemplary.

Silicon-free

eplan download, configurator

www.igus.eu/en/CF11

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

4 travel distance up to 400 m and more 4 oil-resistant)

CF11 TPE 6,8 x d

Halogen-free

Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. CF11.01.04.02 CF11.01.18.02 CF11.02.01.02 CF11.02.02.02(2) CF11.02.03.02 CF11.02.04.02 CF11.02.05.02 CF11.02.06.02 CF11.02.09.02 CF11.02.10.02 CF11.02.14.02 CF11.03.08.02 CF11.05.04.02 CF11.05.06.02 CF11.05.08.02 CF11.07.03.02 CF11.10.04.02 CF11.15.06.02 CF11.25.03.02

Number of cores and conductor nominal cross section [mm2] (4 x (2 x 0,14))C (18 x (2 x 0,14))C (1 x (2 x 0,25))C (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (9 x (2 x 0,25))C (10 x (2 x 0,25))C (14 x (2 x 0,25))C (8 x (2 x 0,34))C (4 x (2 x 0,5))C (6 x (2 x 0,5))C (8 x (2 x 0,5))C (3 x (2 x 0,75))C (4 x (2 x 1,0))C (6 x (2 x 1,5))C (3 x (2 x 2,5))C

External diameter approx. [mm] 7,0 14,0 6,0 6,5 8,0 9,0 9,0 10,0 12,5 13,0 13,5 12,5 10,0 11,5 14,0 11,0 12,0 17,0 16,5

Copper index [kg/km] 28 86 17 25 34 44 55 66 92 99 120 90 91 95 131 77 121 242 210

Weight [kg/km] 64 164 38 52 60 80 100 127 198 200 238 154 108 190 250 131 180 419 410

The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Measuring system cables Page 164, CF211 (PVC) Page 170, CF111.D (TPE) Page 180, CF11.D (TPE)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

121


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 122

CF112 PUR 10 x d

PUR Data cable CF112 ● ● ● ● ● ● ● ●

Class 6.3.3 (6 maximum load requirements

for maximum load requirements PUR outer jacket double-shielded, twisted-pair oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Core identification

Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Intermediate jacket PUR mixture adapted to suit the requirements in energy chains®.

3 travel distance up to 100 m 3 oil-resistant)

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

UL/CSA

Style 10493 and 20233, 300 V, 80°C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

CF112 PUR 10 x d

Element shield

Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016) -20 °C to +80 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 5 x d

Outer jacket

v max. unsupported/gliding 10 m/s, 5 m/s a max. 80 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 High

Nominal voltage

300/300 V (following DIN VDE 0245).

Testing voltage

1500 V

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

Typical application area ● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25)C)C (3 x (2 x 0,25)C)C (4 x (2 x 0,25)C)C (5 x (2 x 0,25)C)C (6 x (2 x 0,25)C)C (2 x (2 x 0,5)C)C (3 x (2 x 0,5)C)C (4 x (2 x 0,5)C)C (5 x (2 x 0,5)C)C (6 x (2 x 0,5)C)C

CF112.02.02.02 CF112.02.03.02(1) CF112.02.04.02 CF112.02.05.02(1) CF112.02.06.02(1) CF112.05.02.02(1) CF112.05.03.02(1) CF112.05.04.02 CF112.05.05.02(1) CF112.05.06.02

External diameter approx. [mm] 9,5 10,0 11,0 11,5 12,0 11,5 12,0 12,5 13,5 14,5

Copper index [kg/km] 54 68 78 95 107 72 95 113 137 155

Weight [kg/km] 125 144 159 184 210 168 192 221 263 307

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

MUD-resistant following NEK 606 – status 2009.

Order example: CF112.02.04.02 – in your desired length (0,5 m steps) CF112 chainflex series .02 Code nominal cross section .04 Number of pairs .02 Identification pairs ®

Please use www.chainflex.eu/en/CF112 for your online order.

Image exemplary.

Delivery time 24h or today. eplan download, configurator

www.igus.eu/en/CF112

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

123


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 124

CF12 TPE 10 x d

Class 6.4.4 (6 maximum load requirements

TPE Data cable CF12 ● ● ● ● ● ● ●

for maximum load requirements TPE outer jacket double-shielded oil-resistant biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant

Conductor Core insulation

Silicon-free

4 travel distance up to 400 m 4 oil-resistant)

CF12 TPE 10 x d

Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.

Typical application area Core stranding Core identification Element shield Element jacket Inner jacket Overall shield

2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: Cores black with white numerals Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains® over pair shield. TPE mixture adapted to suit the requirements in energy chains®.

T/R moved

Highly flexible shield consisting of galvanized steel wire braid. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +100 °C, minimum bending radius 5 x d

Outer jacket

v max. unsupported/gliding 10 m/s, 6 m/s a max. 100 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 400 m, Class 4 High

Nominal voltage

300/300 V (following DIN VDE 0245).

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications, for especially high EMC safety

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25)C)C (3 x (2 x 0,25)C)C (4 x (2 x 0,25)C)C (5 x (2 x 0,25)C)C (3 x (2 x 0,5)C)C (4 x (2 x 0,5)C)C (5 x (2 x 0,5)C)C (6 x (2 x 0,5)C)C (8 x (2 x 0,5)C)C (10 x (2 x 0,5)C)C (14 x (2 x 0,5)C)C (6 x (2 x 1,0)C)C

CF12.02.02.02 CF12.02.03.02(1) CF12.02.04.02 CF12.02.05.02 CF12.05.03.02 CF12.05.04.02 CF12.05.05.02 CF12.05.06.02 CF12.05.08.02 CF12.05.10.02 CF12.05.14.02 CF12.10.06.02

External diameter approx. [mm] 11,0 11,5 11,5 13,0 13,0 14,0 15,5 17,0 20,0 23,0 23,0 20,0

Copper index [kg/km] 27 40 61 93 66 88 110 132 177 221 309 198

Weight [kg/km] 152 172 179 220 210 255 297 360 477 548 723 542

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF12.02.03.02 – in your desired length (0,5 m steps) CF12 chainflex series .02 Code nominal cross section .03 Number of pairs .02 Identification pairs

Image exemplary.

®

Testing voltage

1500 V

Please use www.chainflex.eu/en/CF12 for your online order.

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.

Delivery time 24h or today.

eplan download, configurator

www.igus.eu/en/CF12

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Delivery time means time until shipping of goods.

Test data

Page 41 or www.igus.eu/en/test7

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

125


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 126

CFKoax1 TPE 10 x d

TPE Coax cable CFKoax1 ● ● ● ● ● ●

Class 6.4.4 (6 maximum load requirements

50/75 Ω coax cable for maximum load requirements TPE outer jacket oil-resistant biooil-resistant UV-resistant hydrolysis-resistant and microbe-resistant

4 travel distance up to 400 m 4 oil-resistant)

CFKoax1 TPE 10 x d

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1 The coax elements used in cables of the CF Koax1 series are comparable with a HF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!

Info

Typical application area Conductor Core insulation

Multi-wire; adapted in single-wire diameter and pitch length to suit the requirements in energy chains®. Special FEP-isolating mixture.

Core stranding

Cores stranded in one layer with especially short pitch length.

Identification

Coaxial elements

Element shield

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains®.

Element jacket Outer jacket

Schedule Delivery Program

T/R moved

Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +100 °C, minimum bending radius 7,5 x d

v max. 10 m/s, 5 m/s unsupported/gliding a max. 100 m/s2 Travel distance

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

Delivery program Part No. CFKoax1.01 CFKoax1.05 New* CFKoax2.01

1 coaxial element 5 coaxial elements 1 coaxial element

External diameter approx. [mm] 4,5 10,0 4,5

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Part No.

CFKoax1.01 CFKoax1.05 CFKoax2.01

Freely suspended and gliding travel distances up to 400 m, Class 4

Number of cores

Characteristic wave impedance approx. [Ω] 75 75 50

Number of cores 1 coaxial element 5 coaxial elements 1 coaxial element

Copper index [kg/km] 9 47 7

Weight [kg/km] 25 135 23

*New in this catalogue.

Colour code

Colour Outer Jacket

red red, green, blue, white, black red

Steel blue Steel blue Jet black

Order example: CFKoax1.01 – in your desired length (0,5 m steps) CF Koax1 chainflex series .01 Number of coaxial elements ®

UV-resistant

High

Nominal voltage

300/300 V (following DIN VDE 0245).

Please use www.chainflex.eu/en/CFKOAX1 for your online order. Delivery time 24h or today.

1500 V

Oil

Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following 2006/95/EG

Silicon-free CE

Image exemplary.

Delivery time means time until shipping of goods.

Testing voltage

eplan download, configurator

www.igus.eu/en/CFKOAX1

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Coax cables and other chainflex® cables in platform technology. e-chain®: System E4/4

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

127


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.