EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 110
v max. [m/s] gliding
a max. [m/s2]
Page
-5/ +70
✔
3
2
20
112
CF240.PUR
PUR
✔
10-12
-20/ +80
✔
3
2
20
114 *
Oil-resistant
10-12
Temperature moved from/to [°C]
✔
Shield
PVC
Jacket
CF240
chainflex® cable
v max. [m/s] unsupported
Approvals and standards
Minimum bending radius, moved [factor x d]
chainflex type
Torsion resistant
®
Coaxial cables
Data cables
Data cables – Stranded in layers
Data cables – Twisted pair CF211
PVC
✔
7,5
-5/ +70
✔
5
3
50
116
CF113
PUR
✔
10
-20/ +80
✔
10
5
80
118
CF11
TPE
✔
6,8
-35/ +100
✔
10
6
100
120
Data cables – Twisted pair/Pair shield CF112
PUR
✔
10
-20/ +80
✔
10
5
80
122
CF12
TPE
✔
10
-35/ +100
✔
10
6
100
124
-20/ +80
✔
2
1
20
-35/ +100
✔
10
5
100
Data cables – Thermo (Chapter "Special cables" CF THERMO
PUR
✔ 12,5-15
256)
Data cables – Coax CF KOAX 1
TPE
10
128
111
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 112
CF240 PVC 10-12 x d
PVC Data cable CF240 ● ● ● ● ●
Class 4.2.2 (4 medium load requirements
for medium load requirements PVC outer jacket shielded oil-resistant flame-retardant
Conductor Core insulation Core stranding Core identification
Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. The individual cores are stranded in layers with short pitch lengths. Colour code in accordance with DIN 47100.
Intermediate jacket Foil taping over the external layer. Overall shield Outer jacket
T/R moved
T/R fixed
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 10 x d with < 10 m travel distance, minimum bending radius 12 x d with ≥ 10 m travel distance. -20 °C to +70 °C, minimum bending radius 5 x d
Image exemplary.
v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2 Travel distance
Freely suspended and gliding travel distances up to 50 m, Class 2
Nominal voltage
300/300 V (following DIN VDE 0245).
Testing voltage
1500 V
Oil
Oil-resistant (following DIN EN 50363-4-1), Class 2.
Flame-retardant
According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free
Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
eplan download, configurator
www.igus.eu/en/CF240
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
2 travel distance up to 50 m 2 oil-resistant)
CF240 PVC 10-12 x d
UL/CSA
Style 10493 and 2464, 300 V, 80 °C
NFPA
Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI
Following CEI 20-35
CE
Following 2006/95/EG
Lead free
Following 2011/55/EU (RoHS-II)
Clean room
According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.
Typical application area ● ● ● ● ●
for medium load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 50 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes
Delivery program Part No. CF240.01.03 CF240.01.04 CF240.01.05 CF240.01.07 CF240.01.14 CF240.01.18 CF240.01.24 CF240.02.03 CF240.02.04 CF240.02.05 CF240.02.07 CF240.02.08 CF240.02.14 CF240.02.18 CF240.02.24 CF240.03.03 CF240.03.04 CF240.03.05 CF240.03.07 CF240.03.10 CF240.03.14 CF240.03.18 CF240.03.24
Number of cores and conductor nominal cross section [mm2] (3 x 0,14)C (4 x 0,14)C (5 x 0,14)C (7 x 0,14)C (14 x 0,14)C (18 x 0,14)C (24 x 0,14)C (3 x 0,25)C (4 x 0,25)C (5 x 0,25)C (7 x 0,25)C (8 x 0,25)C (14 x 0,25)C (18 x 0,25)C (24 x 0,25)C (3 x 0,34)C (4 x 0,34)C (5 x 0,34)C (7 x 0,34)C (10 x 0,34)C (14 x 0,34)C (18 x 0,34)C (24 x 0,34)C
External diameter approx. [mm] 4,5 5,0 5,5 6,0 7,0 8,0 9,5 5,5 5,5 6,0 7,0 7,5 8,0 9,0 11,0 5,5 6,0 6,5 7,0 8,5 8,5 10,0 12,0
Copper index [kg/km] 16 18 20 25 42 48 60 21 24 27 35 40 57 71 92 24 28 32 43 55 71 87 115
Weight [kg/km] 35 38 42 51 76 90 113 40 48 52 66 74 100 122 174 45 51 58 75 110 116 140 203
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
113
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 114
CF240.PUR PUR 10-12 x d
PUR Data cable CF240.PUR ● ● ● ● ● ● ● ●
Class 5.2.3 (5 high load requirements
for high load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Core identification
Silicon-free
Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. The individual cores are stranded in layers with short pitch lengths. Colour code in accordance with DIN 47100
2 travel distance up to 50 m 3 oil-resistant)
CF240.PUR PUR 10-12 x d
Halogen-free
Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.
UL/CSA
Style 10493 and 20233, 300 V, 80°C
NFPA
Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI
Following CEI 20-35
CE
Following 2006/95/EG
Lead free
Following 2011/55/EU (RoHS-II)
Clean room
According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1
Intermediate jacket Foil taping over the external layer
Typical application area Overall shield Outer jacket
T/R moved T/R fixed
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Silver gray (similar to RAL 7001) -20 °C to +80 °C, minimum bending radius 10 x d with < 10 m travel distance, minimum bending radius 12 x d with ≥ 10 m travel distance -40 °C to +80 °C, minimum bending radius 5 x d
v max. 3 m/s, 2 m/s unsupported/gliding a max. 20 m/s2
Image exemplary.
Travel distance UV-resistant
Freely suspended and gliding travel distances up to 50 m, Class 2. Medium
Nominal voltage
300/300 V (following DIN VDE 0245)
Testing voltage
1500 V
Oil
Oil-resistant (following DIN EN 50363-10-2), Class 3.
Offshore
MUD-resistant following NEK 606 – status 2009.
Flame-retardant
According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
eplan download, configurator
www.igus.eu/en/CF240PUR
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
● ● ● ● ●
for high load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 50 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector
Delivery program Part No. CF240.PUR.01.03(1) CF240.PUR.01.04 CF240.PUR.01.05(1) CF240.PUR.01.07(1) CF240.PUR.01.14 CF240.PUR.01.18(1) CF240.PUR.02.03 CF240.PUR.02.04 CF240.PUR.02.05 CF240.PUR.02.07 CF240.PUR.02.08 CF240.PUR.02.14 CF240.PUR.02.18 CF240.PUR.03.03(1) CF240.PUR.03.04 CF240.PUR.03.05(1) CF240.PUR.03.07 CF240.PUR.03.14(1) CF240.PUR.03.18(1)
Number of cores and conductor nominal cross section [mm2] (3 x 0,14)C (4 x 0,14)C (5 x 0,14)C (7 x 0,14)C (14 x 0,14)C (18 x 0,14)C (3 x 0,25)C (4 x 0,25)C (5 x 0,25)C (7 x 0,25)C (8 x 0,25)C (14 x 0,25)C (18 x 0,25)C (3 x 0,34)C (4 x 0,34)C (5 x 0,34)C (7 x 0,34)C (14 x 0,34)C (18 x 0,34)C
External diameter approx. [mm] 5,5 6,0 6,5 7,0 8,0 8,5 6,0 6,0 6,5 7,0 7,5 8,0 9,0 6,0 6,5 7,0 8,0 9,5 10,0
Copper index [kg/km] 16 18 20 25 42 48 21 24 27 35 40 57 71 24 28 32 43 71 88
Weight [kg/km] 35 38 43 52 77 92 40 44 49 63 69 100 119 46 52 58 82 123 152
(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
115
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 116
CF211 PVC 7,5 x d
PVC Data cable CF211 ● ● ● ● ● ●
Class 5.3.2 (5 high load requirements
for high load requirements PVC outer jacket shielded twisted-pair oil-resistant flame-retardant
Conductor Core insulation Core stranding Core identification
Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100.
Intermediate jacket Foil taping over the external layer. Overall shield Outer jacket
T/R moved
T/R fixed
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 7,5 x d. Following an extensive series of tests, the bending radius of CF211 has been reduced from 10 x d to 7,5 x d. -20 °C to +70 °C, minimum bending radius 5 x d
v max. 5 m/s, 3 m/s unsupported/gliding a max. 50 m/s2 Travel distance Nominal voltage
Freely suspended and gliding travel distances up to 100 m, Class 3 300/300 V (following DIN VDE 0245).
Testing voltage
1500 V
Oil
Oil-resistant (following DIN EN 50363-4-1), Class 2.
Flame-retardant
According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free
Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10493 and 2464, 300 V, 80 °C
Image exemplary.
UL/CSA
eplan download, configurator
www.igus.eu/en/CF211
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
3 travel distance up to 100 m 2 oil-resistant)
CF211 PVC 7,5 x d
NFPA
Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI
Following CEI 20-35
CE
Following 2006/95/EG
Lead free
Following 2011/55/EU (RoHS-II)
Clean room
According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.
Typical application area ● ● ● ● ●
for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes
Delivery program Part No. CF211.02.01.02 CF211.02.02.02(2) CF211.02.03.02 CF211.02.04.02 CF211.02.05.02 CF211.02.06.02 CF211.02.08.02 CF211.02.10.02 CF211.02.14.02 CF211.03.03.02 CF211.03.08.02 CF211.03.10.02(1) CF211.05.01.02 CF211.05.02.02(2) CF211.05.03.02 CF211.05.04.02 CF211.05.05.02 CF211.05.06.02 CF211.05.08.02 CF211.05.10.02 CF211.05.14.02
Number of cores and conductor nominal cross section [mm2] (1 x (2 x 0,25))C (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (8 x (2 x 0,25))C (10 x (2 x 0,25))C (14 x (2 x 0,25))C (3 x (2 x 0,34))C (8 x (2 x 0,34))C (10 x (2 x 0,34))C (1 x (2 x 0,5))C (2 x (2 x 0,5))C (3 x (2 x 0,5))C (4 x (2 x 0,5))C (5 x (2 x 0,5))C (6 x (2 x 0,5))C (8 x (2 x 0,5))C (10 x (2 x 0,5))C (14 x (2 x 0,5))C
External diameter approx. [mm] 5,0 5,5 7,0 8,0 8,5 9,5 11,5 13,0 13,5 8,0 12,0 12,0 5,5 8,5 9,0 9,5 11,0 12,5 14,5 16,0 17,0
Copper index [kg/km] 16 28 37 44 51 58 75 93 109 37 98 118 23 44 57 68 80 99 124 175 187
Weight [kg/km] 35 60 73 85 97 110 160 195 205 79 202 254 50 80 100 120 145 185 230 320 335
(1) Delivery time upon inquiry. The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
Delivery program Measuring system cables Page 164, CF211 (PVC) Page 170, CF111.D (TPE) Page 180, CF11.D (TPE)
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
117
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 118
CF113 PUR 10 x d
PUR Data cable CF113 ● ● ● ● ● ● ● ●
Class 6.3.3 (6 maximum load requirements
for maximum load requirements PUR outer jacket shielded, twisted-pair oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Core identification
Silicon-free
Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality TPE mixture.
3 travel distance up to 100 m 3 oil-resistant)
Halogen-free
Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.
UL/CSA
Style 10493 and 20233, 300 V, 80°C
NFPA
Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI
Following CEI 20-35
CE
Following 2006/95/EG
Lead free
Following 2011/55/EU (RoHS-II)
CF113 PUR 10 x d
2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100
Typical application area Intermediate jacket PUR mixture adapted to suit the requirements in energy chains . ®
Overall shield Outer jacket
T/R moved T/R fixed
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016) -20 °C to +80 °C, minimum bending radius 10 x d -40 °C to +80 °C, minimum bending radius 5 x d
v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance UV-resistant
Freely suspended and gliding travel distances up to 100 m, Class 3 High
Nominal voltage
300/300 V (following DIN VDE 0245).
Testing voltage
1500 V
Oil
Oil-resistant (following DIN EN 50363-10-2), Class 3.
Offshore
MUD-resistant following NEK 606 – status 2009.
Flame-retardant
According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
.
● ● ● ● ●
for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector
Delivery program Part No.
Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (8 x (2 x 0,25))C (2 x (2 x 0,5))C (3 x (2 x 0,5))C (4 x (2 x 0,5))C (5 x (2 x 0,5))C (6 x (2 x 0,5))C
CF113.02.02.02(2) CF113.02.03.02 CF113.02.04.02 CF113.02.05.02 CF113.02.06.02 CF113.02.08.02 New* CF113.05.02.02(2) CF113.05.03.02(1) CF113.05.04.02 CF113.05.05.02(1) CF113.05.06.02
External diameter approx. [mm] 8,0 8,5 9,0 9,5 10,0 11,5 10,0 10,5 11,0 11,5 12,5
Copper index [kg/km] 31 40 45 56 62 81 50 62 70 84 95
Weight [kg/km] 86 96 107 125 137 176 127 142 162 185 207
(1) Delivery time upon inquiry The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.
Order example: CF113.02.06.02 – in your desired length (0,5 m steps) CF113 chainflex series .02 Code nominal cross section .06 Number of pairs .02 Identification pairs ®
Please use www.chainflex.eu/en/CF113 for your online order.
Image exemplary.
Delivery time 24h or today. eplan download, configurator
www.igus.eu/en/CF113
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
Delivery time means time until shipping of goods.
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
119
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 120
CF11 TPE 6,8 x d
TPE Data cable CF11 ● ● ● ● ● ● ●
Class 6.4.4 (6 maximum load requirements
for maximum load requirements TPE outer jacket shielded twisted-pair oil-resistant, biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant
Conductor Core insulation Core stranding Core identification Inner jacket Overall shield Outer jacket
T/R moved
T/R fixed
Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Cores < 1,0 mm2: Colour code in accordance with DIN 47100 Cores ≥ 1,0 mm2: Cores black with white numerals TPE mixture adapted to suit the requirements in energy chains®. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 6,8 x d. Following an extensive series of tests, the bending radius of CF11 has been reduced from 10 x d to 6,8 x d. -40 °C to +100 °C, minimum bending radius 5 x d
v max. 10 m/s, 6 m/s unsupported/gliding a max. 100 m/s2 Travel distance UV-resistant
Freely suspended and gliding travel distances up to 400 m and more, Class 4 High
Nominal voltage
300/300 V (following DIN VDE 0245).
Testing voltage
1500 V
Oil
Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992).
Image exemplary.
Silicon-free
eplan download, configurator
www.igus.eu/en/CF11
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
4 travel distance up to 400 m and more 4 oil-resistant)
CF11 TPE 6,8 x d
Halogen-free
Following EN 50267-2-1.
CE
Following 2006/95/EG
Lead free
Following 2011/55/EU (RoHS-II)
Clean room
According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1
Typical application area ● ● ● ● ●
for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications
Delivery program Part No. CF11.01.04.02 CF11.01.18.02 CF11.02.01.02 CF11.02.02.02(2) CF11.02.03.02 CF11.02.04.02 CF11.02.05.02 CF11.02.06.02 CF11.02.09.02 CF11.02.10.02 CF11.02.14.02 CF11.03.08.02 CF11.05.04.02 CF11.05.06.02 CF11.05.08.02 CF11.07.03.02 CF11.10.04.02 CF11.15.06.02 CF11.25.03.02
Number of cores and conductor nominal cross section [mm2] (4 x (2 x 0,14))C (18 x (2 x 0,14))C (1 x (2 x 0,25))C (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (9 x (2 x 0,25))C (10 x (2 x 0,25))C (14 x (2 x 0,25))C (8 x (2 x 0,34))C (4 x (2 x 0,5))C (6 x (2 x 0,5))C (8 x (2 x 0,5))C (3 x (2 x 0,75))C (4 x (2 x 1,0))C (6 x (2 x 1,5))C (3 x (2 x 2,5))C
External diameter approx. [mm] 7,0 14,0 6,0 6,5 8,0 9,0 9,0 10,0 12,5 13,0 13,5 12,5 10,0 11,5 14,0 11,0 12,0 17,0 16,5
Copper index [kg/km] 28 86 17 25 34 44 55 66 92 99 120 90 91 95 131 77 121 242 210
Weight [kg/km] 64 164 38 52 60 80 100 127 198 200 238 154 108 190 250 131 180 419 410
The chainflex® types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
Delivery program Measuring system cables Page 164, CF211 (PVC) Page 170, CF111.D (TPE) Page 180, CF11.D (TPE)
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
121
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 122
CF112 PUR 10 x d
PUR Data cable CF112 ● ● ● ● ● ● ● ●
Class 6.3.3 (6 maximum load requirements
for maximum load requirements PUR outer jacket double-shielded, twisted-pair oil-resistant and coolant-resistant notch-resistant PVC-free/halogen-free flame-retardant hydrolysis-resistant and microbe-resistant Conductor Core insulation Core stranding Core identification
Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Intermediate jacket PUR mixture adapted to suit the requirements in energy chains®.
3 travel distance up to 100 m 3 oil-resistant)
Flame-retardant
According to IEC 60332-1-2, CEI 20-35, FT1, VW-1
Silicon-free Halogen-free
Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.
UL/CSA
Style 10493 and 20233, 300 V, 80°C
NFPA
Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)
CEI
Following CEI 20-35
CE
Following 2006/95/EG
Lead free
Following 2011/55/EU (RoHS-II)
CF112 PUR 10 x d
Element shield
Overall shield
T/R moved
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016) -20 °C to +80 °C, minimum bending radius 10 x d
T/R fixed
-40 °C to +80 °C, minimum bending radius 5 x d
Outer jacket
v max. unsupported/gliding 10 m/s, 5 m/s a max. 80 m/s2 Travel distance UV-resistant
Freely suspended and gliding travel distances up to 100 m, Class 3 High
Nominal voltage
300/300 V (following DIN VDE 0245).
Testing voltage
1500 V
Oil
Oil-resistant (following DIN EN 50363-10-2), Class 3.
Offshore
Typical application area ● ● ● ● ●
for maximum load requirements almost unlimited resistance to oil indoor and outdoor applications with average sun radiation especially for freely suspended and gliding travel distances up to 100 m Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector
Delivery program Part No.
Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25)C)C (3 x (2 x 0,25)C)C (4 x (2 x 0,25)C)C (5 x (2 x 0,25)C)C (6 x (2 x 0,25)C)C (2 x (2 x 0,5)C)C (3 x (2 x 0,5)C)C (4 x (2 x 0,5)C)C (5 x (2 x 0,5)C)C (6 x (2 x 0,5)C)C
CF112.02.02.02 CF112.02.03.02(1) CF112.02.04.02 CF112.02.05.02(1) CF112.02.06.02(1) CF112.05.02.02(1) CF112.05.03.02(1) CF112.05.04.02 CF112.05.05.02(1) CF112.05.06.02
External diameter approx. [mm] 9,5 10,0 11,0 11,5 12,0 11,5 12,0 12,5 13,5 14,5
Copper index [kg/km] 54 68 78 95 107 72 95 113 137 155
Weight [kg/km] 125 144 159 184 210 168 192 221 263 307
(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
MUD-resistant following NEK 606 – status 2009.
Order example: CF112.02.04.02 – in your desired length (0,5 m steps) CF112 chainflex series .02 Code nominal cross section .04 Number of pairs .02 Identification pairs ®
Please use www.chainflex.eu/en/CF112 for your online order.
Image exemplary.
Delivery time 24h or today. eplan download, configurator
www.igus.eu/en/CF112
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
Delivery time means time until shipping of goods.
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
123
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 124
CF12 TPE 10 x d
Class 6.4.4 (6 maximum load requirements
TPE Data cable CF12 ● ● ● ● ● ● ●
for maximum load requirements TPE outer jacket double-shielded oil-resistant biooil-resistant PVC-free/halogen-free hydrolysis-resistant and microbe-resistant
Conductor Core insulation
Silicon-free
4 travel distance up to 400 m 4 oil-resistant)
CF12 TPE 10 x d
Halogen-free
Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.
CE
Following 2006/95/EG
Lead free
Following 2011/55/EU (RoHS-II)
Clean room
According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1
Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture.
Typical application area Core stranding Core identification Element shield Element jacket Inner jacket Overall shield
2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Cores < 0,5 mm2: Colour code in accordance with DIN 47100 Cores ≥ 0,5 mm2: Cores black with white numerals Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains® over pair shield. TPE mixture adapted to suit the requirements in energy chains®.
T/R moved
Highly flexible shield consisting of galvanized steel wire braid. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 10 x d
T/R fixed
-40 °C to +100 °C, minimum bending radius 5 x d
Outer jacket
v max. unsupported/gliding 10 m/s, 6 m/s a max. 100 m/s2 Travel distance UV-resistant
Freely suspended and gliding travel distances up to 400 m, Class 4 High
Nominal voltage
300/300 V (following DIN VDE 0245).
● ● ● ● ●
for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications, for especially high EMC safety
Delivery program Part No.
Number of cores and conductor nominal cross section [mm2] (2 x (2 x 0,25)C)C (3 x (2 x 0,25)C)C (4 x (2 x 0,25)C)C (5 x (2 x 0,25)C)C (3 x (2 x 0,5)C)C (4 x (2 x 0,5)C)C (5 x (2 x 0,5)C)C (6 x (2 x 0,5)C)C (8 x (2 x 0,5)C)C (10 x (2 x 0,5)C)C (14 x (2 x 0,5)C)C (6 x (2 x 1,0)C)C
CF12.02.02.02 CF12.02.03.02(1) CF12.02.04.02 CF12.02.05.02 CF12.05.03.02 CF12.05.04.02 CF12.05.05.02 CF12.05.06.02 CF12.05.08.02 CF12.05.10.02 CF12.05.14.02 CF12.10.06.02
External diameter approx. [mm] 11,0 11,5 11,5 13,0 13,0 14,0 15,5 17,0 20,0 23,0 23,0 20,0
Copper index [kg/km] 27 40 61 93 66 88 110 132 177 221 309 198
Weight [kg/km] 152 172 179 220 210 255 297 360 477 548 723 542
(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core
Order example: CF12.02.03.02 – in your desired length (0,5 m steps) CF12 chainflex series .02 Code nominal cross section .03 Number of pairs .02 Identification pairs
Image exemplary.
®
Testing voltage
1500 V
Please use www.chainflex.eu/en/CF12 for your online order.
Oil
Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4.
Delivery time 24h or today.
eplan download, configurator
www.igus.eu/en/CF12
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
Delivery time means time until shipping of goods.
Test data
Page 41 or www.igus.eu/en/test7
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
125
EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:55 Seite 126
CFKoax1 TPE 10 x d
TPE Coax cable CFKoax1 ● ● ● ● ● ●
Class 6.4.4 (6 maximum load requirements
50/75 Ω coax cable for maximum load requirements TPE outer jacket oil-resistant biooil-resistant UV-resistant hydrolysis-resistant and microbe-resistant
4 travel distance up to 400 m 4 oil-resistant)
CFKoax1 TPE 10 x d
Lead free
Following 2011/55/EU (RoHS-II)
Clean room
According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1 The coax elements used in cables of the CF Koax1 series are comparable with a HF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!
Info
Typical application area Conductor Core insulation
Multi-wire; adapted in single-wire diameter and pitch length to suit the requirements in energy chains®. Special FEP-isolating mixture.
Core stranding
Cores stranded in one layer with especially short pitch length.
Identification
Coaxial elements
Element shield
Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in energy chains®.
Element jacket Outer jacket
Schedule Delivery Program
T/R moved
Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in energy chains®. Colour: Steel blue (similar to RAL 5011) -35 °C to +100 °C, minimum bending radius 10 x d
T/R fixed
-40 °C to +100 °C, minimum bending radius 7,5 x d
v max. 10 m/s, 5 m/s unsupported/gliding a max. 100 m/s2 Travel distance
● ● ● ● ●
for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications
Delivery program Part No. CFKoax1.01 CFKoax1.05 New* CFKoax2.01
1 coaxial element 5 coaxial elements 1 coaxial element
External diameter approx. [mm] 4,5 10,0 4,5
Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.
Part No.
CFKoax1.01 CFKoax1.05 CFKoax2.01
Freely suspended and gliding travel distances up to 400 m, Class 4
Number of cores
Characteristic wave impedance approx. [Ω] 75 75 50
Number of cores 1 coaxial element 5 coaxial elements 1 coaxial element
Copper index [kg/km] 9 47 7
Weight [kg/km] 25 135 23
*New in this catalogue.
Colour code
Colour Outer Jacket
red red, green, blue, white, black red
Steel blue Steel blue Jet black
Order example: CFKoax1.01 – in your desired length (0,5 m steps) CF Koax1 chainflex series .01 Number of coaxial elements ®
UV-resistant
High
Nominal voltage
300/300 V (following DIN VDE 0245).
Please use www.chainflex.eu/en/CFKOAX1 for your online order. Delivery time 24h or today.
1500 V
Oil
Oil-resistant (following DIN EN 60811-2-1), biooil-resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following 2006/95/EG
Silicon-free CE
Image exemplary.
Delivery time means time until shipping of goods.
Testing voltage
eplan download, configurator
www.igus.eu/en/CFKOAX1
950 types from stock no cutting costs ... (for up to 10 cuts of the same type)
Coax cables and other chainflex® cables in platform technology. e-chain®: System E4/4
... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu
127