twisterband assembly
Dimensioning: Cable selection
!
TPE outer jacket
When selecting cables, pay attention particularly to good wear and glide properties. TPE is the ideal jacket material. Recommended: chainflex® cable CF9
We are currently developing special shielded cables to be used inside the twisterband. Please contact us if the use of shielded cables is required.
Dimensioning: Filling twisterband version with locking: TB20.44.18.x.01.0 TB30.75.22.x.01.0
twisterband version with easy-locking: TB12.23.09.x.01.0 TB20.44.12.x.01.0 Insert cables sorted according to min. 2 mm diameter and/or bending radius. Insert thin, small ones inward – then increasingly bigger ones outward.
min. 2 mm Separate cables with separators
min. 2 mm
min. 2 mm
Insert cables sorted according to diameter and/or bending radius. Insert thin, small ones inward – then increasingly bigger ones outward.
min. 4 mm
min. 2 mm
min. 4 mm Not more than two cables one upon the other. Between all cables 10% of the larger diameter or a minimum of 1 mm
min. 2 mm
min. 4 mm
min. 2 mm
Between all cables min. 1 mm or 10% of the larger diameter => Ø B
min. 2 mm
min. 2 mm Between all cables a minimum of 1 mm or 10% of the larger diameter Between all cables and separators 10% of the larger diameter or a minimum of 1 mm
min. 2 mm
min. 4 mm Not more than two cables one upon the other. Between all cables 10% of the larger diameter or a minimum of 1 mm
twisterband assembly
Installation: Mounting brackets
1. Insert twisterband between the steel parts.
2. Fixing of the twisterband with the mounting bracket by screwing.
Installation: Guide shaft
Insert a centric shaft as a guide in vertical installation position from 1500° rotation angle.
Basically, insert a centric shaft as support in horizontal installation position.
Installation: Strain relief
End position:
igus® GmbH Cologne plastics for longer life
®
The twisterband must not be twisted up to the end. To avoid immense strain on the cables, a reserve of min. 90° must be planned in front of each mounting point.
Phone: +49-2203-9649-800
www.igus.eu
MAT0071842.20
Apply strain relief on both ends of cables Ensure that the knot of the cable tie does not point toward the energy chain®