10

CF21.UL

PVC

7,5

-5/ +70

10

CF270.UL.D

PUR

10

-20/ +80

10

CF27.D

PUR

7,5

-20/ +80

10

Page

-5/ +70

a max. [m/s2]

10

v max. [m/s] gliding

Temperature, moved from/to [°C]

v max. [m/s] unsupported

Min. bending radius, moved [factor x d]

PVC

Oil-resistant

Shield

Approvals and standards

Jacket

CF210.UL

chainflex® cable

Servo cables

chainflex type

Torsion resistant

®

50

188

80

190

50

194

80

198

Servo cables

5

5

187


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 188

CF210.UL PVC 10 x d

PVC Servo cable CF210.UL ● ● ● ● ●

Class 4.1.2 (4 medium load requirements

for medium load requirements PVC outer jacket shielded oil-resistant flame-retardant

Fine-wire stranded conductor in bending-resistant version consisting of bare copper wires (following EN 60228). Core insulation Mechanically high-quality, especially low-capacitance TPE mixture. Core stranding Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Core identification Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 signal pair: Cores black with white numerals. 1. control core: 4 2. control core: 5 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 Star-quad: yellow, black, red, white Element shield Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Intermediate jacket Foil taping over the external layer.

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1

Silicon-free UL

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10989 and 2570, 1000 V, 80 °C

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

Conductor

Overall shield Outer jacket

T/R moved

Image exemplary.

T/R fixed

Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Pastellorange (similar to RAL 2003) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 10 x d. -20 °C to +70 °C, minimum bending radius 5 x d

v max. freely suspended a max.

10 m/s 50 m/s2

Travel distance

Freely suspended travel distances, Class 1

UV-resistant

Medium

eplan download, configurator

1 freely suspended 2 oil-resistant)

CF210.UL PVC 10 x d

Typical application area ● ● ● ● ●

for medium load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended travel distances Wood/stone processing, packaging industry, supply system, handling, adjusting equipment

Delivery program Part No. 1 signal pair shielded CF210.UL.15.15.02.01 CF210.UL.25.15.02.01 CF210.UL.40.15.02.01 CF210.UL.60.15.02.01(1) 2 signal pairs shielded CF210.UL.15.07.02.02 CF210.UL.25.15.02.02 CF210.UL.40.15.02.02 CF210.UL.60.15.02.02(1)

Number of cores and conductor nominal cross section [mm2] (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4,0+2x(2x1,5)C)C (4 G 6,0+2x(2x1,5)C)C

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

12,0 13,5 15,0 16,5

149 203 272 364

250 320 412 521

13,5 15,5 17,0 18,5

169 260 330 425

290 408 506 633

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

www.igus.eu/en/CF210UL

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

189


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 190

CF21.UL PVC 7,5 x d

PVC Servo cable CF21.UL ● ● ● ● ●

Class 5.3.2 (5 high load requirements

for high load requirements PVC outer jacket shielded oil-resistant flame-retardant

Conductor Core insulation Core stranding Core identification

Element shield Inner jacket Overall shield Outer jacket

T/R moved

T/R fixed

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 signal pair: Cores black with white numerals. 1. control core: 4 2. control core: 5 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. PVC mixture adapted to suit the requirements in energy chains®. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in energy chains® (following DIN VDE 0281 Part 13). Colour: Moss green (similar to RAL 6005) -5 °C to +70 °C following DIN EN 60811, part 1-4 chapter 8.2. +5 °C to +70 °C for use in energy chains® with > 50.000 cycles. Minimum bending radius 7,5 x d. -20 °C to +70 °C, minimum bending radius 4 x d

3 travel distance up to 100 m 2 oil-resistant)

CF21.UL PVC 7,5 x d

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-4-1), Class 2.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free UL/CSA

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Style 10492 and 2570, 1000 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1.

Typical application area ● ● ● ● ●

for high load requirements light oil influence preferably indoor applications, but also outdoor ones at temperatures > 5 °C especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 Medium

Image exemplary.

chainflex® CF21.UL: cables for energy supply systems in spinneret production. e-chain®: Serie E2/000

eplan download, configurator

www.igus.eu/en/CF21UL

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Test data

Page 50 or www.igus.eu/en/test12

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

191


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 192

CF21.UL PVC 7,5 x d

PVC Servo cable CF21.UL

Class 5.3.2 (5 high load requirements

3 travel distance up to 100 m 2 oil-resistant)

CF21.UL PVC 7,5 x d

Image exemplary.

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 0,75+(2x0,5)C)C (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 10+(2x1,5)C)C (4 G 16+(2x1,5)C)C (4 G 25+(2x1,5)C)C (4 G 35+(2x1,5)C)C

1 signal pair shielded CF21.07.05.02.01.UL CF21.15.15.02.01.UL CF21.25.15.02.01.UL CF21.40.15.02.01.UL CF21.60.15.02.01.UL CF21.100.15.02.01.UL CF21.160.15.02.01.UL(1) CF21.250.15.02.01.UL(1) CF21.350.15.02.01.UL(1) 2 signal pairs shielded CF21.07.03.02.02.UL (4 G 0,75+2x(2x0,34)C)C CF21.10.07.02.02.UL (4 G 1,0+2x(2x0,75)C)C CF21.15.07.02.02.UL (4 G 1,5+2x(2x0,75)C)C CF21.25.15.02.02.UL (4 G 2,5+2x(2x1,5)C)C CF21.40.15.02.02.UL (4 G 4,0+2x(2x1,5)C)C CF21.60.15.02.02.UL (4 G 6,0+2x(2x1,5)C)C CF21.100.15.02.02.UL (4 G 10+2x(2x1,5)C)C CF21.160.15.02.02.UL (4 G 16+2x(2x1,5)C)C CF21.250.15.02.02.UL (4 G 25+2x(2x1,5)C)C CF21.350.15.02.02.UL (4 G 35+2x(2x1,5)C)C

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

11,5 13,0 14,0 15,5 18,0 22,5 24,5 29,5 33,0

95 144 197 256 357 540 716 1056 1557

185 280 312 412 605 925 1165 1466 2090

12,5 13,5 14,5 17,0 18,5 21,0 24,0 27,0 31,0 34,0

113 146 175 265 313 409 594 790 1140 1597

217 277 324 450 527 712 1025 1270 1910 2175

Order example: CF21.15.15.02.01.UL – in your desired length (0,5 m steps) CF21.UL chainflex series .15 Code nominal cross section .15 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs ®

Please use www.chainflex.eu/en/CF21UL for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

www.igus.eu/en/CF21UL

950 types from stock no cutting costs ... 192

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

193


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 194

CF270.UL.D PUR 10 x d

PUR Servo cable CF270.UL.D ● ● ● ● ● ● ● ●

Class 4.1.3 (4 medium load requirements

for medium load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant PVC-free/halogen-free Fine-wire stranded conductor in bending-resistant version consisting of bare copper wires (following EN 60228) Core insulation Mechanically high-quality, especially low-capacitance TPE mixture. Core stranding Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Core identification Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 signal pair: Cores black with white numerals. 1. control core: 4 2. control core: 5 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 1 Control triple: Cores black with white numerals. 1. control core: 1 2. control core: 2 3. control core: 3 Star-quad: yellow, black, red, white Element shield Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Intermediate jacket Foil taping over the external layer.

1 freely suspended 3 oil-resistant)

CF270.UL.D PUR 10 x d

UV-resistant

Medium

Nominal voltage

600/1000 V (following DIN VDE 0250).

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

UL/CSA

Style 10989 and 21223, 1000 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Conductor

Overall shield

T/R moved

Bending-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Pastel orange (similar to RAL 2003) -20 °C to +80 °C, minimum bending radius 10 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 5 x d

v max. freely suspended a max.

10 m/s 50 m/s2

Travel distance

Freely suspended travel distances, Class 1

Image exemplary.

Outer jacket

eplan download, configurator

Typical application area ● ● ● ● ●

for medium load requirements almost unlimited resistance to oil indoor and outdoor applications without direct sun radiation especially for freely suspended travel distances Machining units/machine tools, low temperature applications

www.igus.eu/en/CF270ULD

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

195


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 196

CF270.UL.D PUR 10 x d

PUR Servo cable CF270.UL.D

Class 4.1.3 (4 medium load requirements

1 freely suspended 3 oil-resistant)

CF270.UL.D PUR 10 x d

Image exemplary.

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 10,0+(2x1,5)C)C (4 G 16,0+(2x1,5)C)C

1 signal pair shielded CF270.UL.15.15.02.01.D CF270.UL.25.15.02.01.D CF270.UL.40.15.02.01.D CF270.UL.60.15.02.01.D CF270.UL.100.15.02.01.D CF270.UL.160.15.02.01.D 2 signal pairs shielded CF270.UL.07.03.02.02.D (4 G 0,75+2x(2x0,34)C)C CF270.UL.10.07.02.02.D (4 G 1,0+2x(2x0,75)C)C CF270.UL.15.07.02.02.D (4 G 1,5+2x(2x0,75)C)C CF270.UL.25.15.02.02.D (4 G 2,5+2x(2x1,5)C)C CF270.UL.40.15.02.02.D (4 G 4,0+2x(2x1,5)C)C CF270.UL.60.15.02.02.D(1) (4 G 6,0+2x(2x1,5)C)C CF270.UL.100.15.02.02.D (4 G 10,0+2x(2x1,5)C)C CF270.UL.160.15.02.02.D(1) (4 G 16,0+2x(2x1,5)C)C CF270.UL.250.15.02.02.D (4 G 25,0+2x(2x1,5)C)C CF270.UL.350.15.02.02.D(1) (4 G 35,0+2x(2x1,5)C)C 1 Control triple CF270.UL.15.10.03.01.D(9) (4 G 1,5+(3x1,0)C)C (10) CF270.UL.25.10.03.01.D (4 G 2,5+(3x1,0)C)C 1 Star-quad shielded CF270.UL.60.05.04.D (4 G 6,0+(4x0,5)C)C Without signal pair CF270.UL.15.04.D (4 G 1,5)C CF270.UL.25.04.D (4 G 2,5)C CF270.UL.40.04.D (4 G 4,0)C CF270.UL.60.04.D (4 G 6,0)C CF270.UL.100.04.D (4 G 10,0)C CF270.UL.160.04.D (4 G 16,0)C CF270.UL.250.04.D (4 G 25,0)C CF270.UL.350.04.D (4 G 35,0)C

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

12,0 13,5 15,0 16,5 20,5 24,0

149 203 272 364 582 855

246 317 408 521 841 1225

11,5 13,0 13,5 15,5 17,0 18,5 22,0 26,0 28,0 35,0

107 143 169 260 330 425 632 901 1365 1804

197 251 290 408 506 633 940 1315 1847 2516

14,0 14,0

160 203

288 327

16,5

350

512

9,0 11,0 12,5 14,5 18,0 21,5 25,5 33,0

82 141 211 306 496 782 1197 1695

147 224 309 434 698 1052 1572 2312

Order example: CF270.UL.25.15.02.01.D – in your desired length (0,5 m steps) CF270.UL.D chainflex series .25 Code nominal cross section .15 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs ®

Please use www.chainflex.eu/en/CF270ULD for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

(1) Delivery time upon inquiry. (9) core/core: 50 pF/m, core/Shield: 95 pF/m (10) core/core: 70 pF/m, core/Shield: 115 pF/m Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

950 types from stock no cutting costs ... 196

(for up to 10 cuts of the same type)

www.igus.eu/en/CF270ULD

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

197


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 198

CF27.D PUR 7,5 x d

PUR Servo cable CF27.D ● ● ● ● ● ● ● ●

Class 6.3.3 (6 maximum load requirements

for maximum load requirements PUR outer jacket shielded oil-resistant and coolant-resistant notch-resistant flame-retardant hydrolysis-resistant and microbe-resistant PVC-free/halogen-free Conductor Core insulation Core identification

Core stranding Element shield Inner jacket

Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Energy conductor: Cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 signal pair: Cores black with white numerals. 1. control core: 4 2. control core: 5 2 signal pairs: Cores black with white numerals. 1. control core: 5 2. control core: 6 3. control core: 7 4. control core: 8 Star-quad: yellow, black, red, white Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. PUR mixture adapted to suit the requirements in energy chains®.

3 travel distance up to 100 m 3 oil-resistant)

CF27.D PUR 7,5 x d

Testing voltage

4000 V (following DIN VDE 0281-2).

Oil

Oil-resistant (following DIN EN 50363-10-2), Class 3.

Offshore

MUD-resistant following NEK 606 – status 2009.

Flame-retardant

According to IEC 60332-1-2, CEI 20-35, FT1, VW-1

Silicon-free Halogen-free

Free from silicon which can affect paint adhesion (following PV 3.10.7 – status 1992). Following EN 50267-2-1.

UL/CSA

Style 10492 and 20234, 1000 V, 80 °C

NFPA

Following NFPA 79-2012 chapter 12.9 (starting from manufacturing date 9/2011)

CEI

Following CEI 20-35

CE

Following 2006/95/EG

DESINA

According to VDW, DESINA standardisation

Lead free

Following 2011/55/EU (RoHS-II)

Clean room

According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

Typical application area Overall shield

T/R moved

Extremely bending-resistant braiding made of tinned copper wires. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in energy chains® (following DIN VDE 0282 Part 10). Colour: Pastel orange (similar to RAL 2003) -20 °C to +80 °C, minimum bending radius 7,5 x d

T/R fixed

-40 °C to +80 °C, minimum bending radius 4 x d

Outer jacket

● ● ● ● ●

for maximum load requirements almost unlimited resistance to oil Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 100 m Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications

v max. 10 m/s, 5 m/s unsupported/gliding a max. 80 m/s2 Travel distance UV-resistant

Freely suspended and gliding travel distances up to 100 m, Class 3 Medium

Nominal voltage

600/1000 V (following DIN VDE 0250).

Image exemplary.

Modular design, easy to retrofit: igus® E4 energy supply system and chainflex® cables.

eplan download, configurator

www.igus.eu/en/CF27D

950 types from stock no cutting costs ... (for up to 10 cuts of the same type)

Test data

Page 30 or www.igus.eu/en/test1

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

199


EU-CF-INHALT 2012-06_EU-CF-INHALT 2012-06 21.05.12 00:59 Seite 200

CF27.D PUR 7,5 x d

PUR Servo cable CF27.D

Class 6.3.3 (6 maximum load requirements

3 travel distance up to 100 m 3 oil-resistant)

CF27.D PUR 7,5 x d

Image exemplary.

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 0,75+(2x0,5)C)C (4 G 1,5+(2x1,0)C)C (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,0)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 10,0+(2x1,5)C)C (4 G 16,0+(2x1,5)C)C (4 G 25,0+(2x1,5)C)C (4 G 35,0+(2x1,5)C)C

1 signal pair shielded CF27.07.05.02.01.D CF27.15.10.02.01.D(11) CF27.15.15.02.01.D CF27.25.10.02.01.D(11) CF27.25.15.02.01.D CF27.40.15.02.01.D CF27.60.15.02.01.D CF27.100.15.02.01.D CF27.160.15.02.01.D CF27.250.15.02.01.D CF27.350.15.02.01.D 2 signal pairs shielded CF27.07.03.02.02.D (4 G 0,75+2x(2x0,34)C)C CF27.10.07.02.02.D (4 G 1,0+2x(2x0,75)C)C CF27.15.07.02.02.D (4 G 1,5+2x(2x0,75)C)C CF27.25.15.02.02.D (4 G 2,5+2x(2x1,5)C)C CF27.40.15.02.02.D (4 G 4,0+2x(2x1,5)C)C CF27.60.15.02.02.D (4 G 6,0+2x(2x1,5)C)C CF27.100.15.02.02.D (4 G 10,0+2x(2x1,5)C)C CF27.160.15.02.02.D (4 G 16,0+2x(2x1,5)C)C CF27.250.15.02.02.D (4 G 25,0+2x(2x1,5)C)C (1) CF27.350.15.02.02.D (4 G 35,0+2x(2x1,5)C)C 1 Star-quad shielded CF27.15.05.04.D (4 G 1,5+(4x0,5)C)C CF27.25.05.04.D (4 G 2,5+(4x0,5)C)C CF27.40.05.04.D (4 G 4,0+(4x0,5)C)C CF27.60.05.04.D (4 G 6,0+(4x0,5)C)C

External diameter approx. [mm]

Copper index [kg/km]

Weight [kg/km]

11,5 12,5 13,0 14,0 14,5 16,0 17,5 21,5 24,5 28,5 32,5

95 130 144 184 199 257 357 540 716 1140 1560

175 226 260 297 325 402 580 900 1150 1523 2079

12,5 13,5 14,0 16,5 18,0 20,0 23,5 26,0 31,0 33,5

105 152 175 265 314 410 594 790 1200 1597

206 265 300 412 485 643 1000 1250 1890 2150

13,0 14,5 16,0 17,5

142 199 256 371

310 348 480 550

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2] (4 G 0,75)C (4 G 1,0)C (4 G 1,5)C (4 G 2,5)C (4 G 50,0)C

Without signal pair CF27.07.04.D(1) CF27.10.04.D(1) CF27.15.04.D CF27.25.04.D CF27.500.04.D

External diameter approx. [mm] 9,5 10,0 10,5 12,5 37,0

Copper index [kg/km]

Weight [kg/km]

52 62 86 140 2230

113 126 163 260 3200

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. x = without earth core G = with green-yellow earth core

Order example: CF27.15.10.02.01.D – in your desired length (0,5 m steps) CF27 chainflex series .15 Code nominal cross section .10 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs ®

Please use www.chainflex.eu/en/CF27D for your online order. Delivery time 24h or today. Delivery time means time until shipping of goods.

(1) Delivery time upon inquiry. (11) Phase-out model Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

eplan download, configurator

www.igus.eu/en/CF27D

950 types from stock no cutting costs ... 200

(for up to 10 cuts of the same type)

... no minimum order quantity ... igus® GmbH Cologne | Tel. +49(0)2203/9649-800 Fax -222 | info@igus.de | www.chainflex.eu

201


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.