Process catalogue 2017

Page 1

Energy

Process Catalogue Oil, Gas & Chemical Solutions

Engineering GREAT Solutions



Contents

1 2

5 6

PRESSURE SWITCHES & SENSORS

AIR PREPARATION (FRL)

ANCILLARY PRODUCTS

ADDITIONAL PRODUCTS

80 81 82 83 84 85 86

FAST FIND GUIDE 140 SERIES 422 SERIES 422 IS SERIES VP10 RANGE 100X SERIES 220 SERIES

88 89 92 94 96

FAST FIND GUIDE 18D ATEX & HYDRAULIC RANGE 20D ALLFLUID & HYDRAULCI RANGE 33D HYD/ALLFLUID RANGE 18S ALLFLUID RANGE

98 99 100 101 103 104 105 106

FAST FIND GUIDE F22, R22 & L22 STAINLESS STEEL AIR PREPARATION RANGE 3 STAGE FILTRATION SYSTEM B38, B38P & B38 AND R38 INSTRUMENT RANGES IFR3, IFR4 STAINLESS STEEL FILTER REGULATOR RANGE B05, R05 GENERAL PURPOSE STAINLESS STEEL RANGE W11, W12, W13 IN-LINE FILTRATION RANGE B72, B74, B68 RANGES STANDARD FILTER REGULATORS

110 FAST FIND GUIDE 111 QEV QUICK EXHAUST VALVES 112 0613422/3 EXHAUST GUARD 113 MB HEAVY DUTY SILENCERS 114 0014, 0613, T40 & M/S SILENCERS

118 INTEGRATED VALVE AND ACTUATOR CONTROL (IVAC) 118 IMPACT (‘RAPPING’) CYLINDER 119 CONTROL PANEL SOLUTIONS

All of our products are backed with an industry leading 2-year warranty. Our dedicated team of experts is on hand with technical advice, support and recommendations to help you get the most effective products, in the shortest timescales, and with the best possible service.

For further information www.imi-precision.com

4

I/P & E/P CONVERTERS

PRODUCT SELECTOR FAST FIND GUIDE IMI HERION VALVES - INTERCHANGEABLE COILS IMI MAXSEAL VALVES - INTEGRATED SOLENOIDS IMI BUSCHJOST DIAPHRAGM VALVES IMI BUSCHJOST PISTON SEAT VALVES IMI BUSCHJOST ANGLE SEAT PILOT VALVES REDUNDANT VALVE MANIFOLD SYSTEM IMI HERION BOOSTERS

1

3

VALVES

16 22 24 57 64 70 72 73 77


2

Engineering GREAT solutions For further information www.imi-precision.com

We deliver GREAT solutions for our customers tackling the world’s most demanding engineering challenges

IMI Precision Engineering is a world leader in motion and fluid control technologies. Wherever precision, speed and engineering reliability are essential, we deliver exceptional solutions which improve the productivity and efficiency of our customers’ equipment. Part of IMI plc, we have a sales and service network in 75 countries, as well as manufacturing capability in the USA, Germany, China, UK, Switzerland, Czech Republic, Mexico and Brazil. We support this with our global centres of technical excellence, and facilities for CFD design and R&D testing. We employ a dedicated team of field engineers, sector specialists and key account managers – all committed to providing excellent service to our customers.

As a business, we aim to UNDERSTAND our customers’ challenges. We then CONNECT our products, people and expertise in order to DELIVER exceptional service and solutions. These IMPROVE the performance of our customers’ machinery. We call this Engineering GREAT, and we deliver it to customers through a world-class portfolio of high performance products, through close partnerships and problem-solving, and through a global network of support which ensures reliable local delivery, all over the world.


We have a global team of key account managers and over 400 highly experienced engineers – many with in‑depth expertise of key industry sectors. We recruit and develop the industry’s top talent, offering the best training and exposure to world-class products and technologies with some of the world’s leading businesses. The deep and combined experience this gives us means we have the skills, confidence and knowhow to get closer to our customers, enabling us to understand their exact challenges and resolve them precisely. Because of this our problem‑solving is more effective, our solutions more targeted, our partnerships more productive.

High performance products

Reliability

Our world-class products improve performance and productivity.

We deliver and support our high quality products through our global service network.

We have global manufacturing capability and technical centres of excellence, each dedicated to developing and rigorously testing new high performance products to meet precise industry and application needs. Helping improve performance and reduce downtime and energy consumption on production lines across the world, our world-class portfolio includes IMI Norgren, IMI Buschjost, IMI FAS, IMI Herion and IMI Maxseal. Having proven their value over years, they stand amongst the most trusted names in fluid and motion control. We are continuously adding to this portfolio through a programme of innovation and new product development. Because of this, we’re able help our customers solve the world’s greatest engineering challenges – reliably, safely and efficiently.

We have world-class manufacturing and sales and service operations in 75 countries, supported by investment in robust project management systems and lean localised production. Together, with our integrated supply chain, and the speed of our Express service we have the systems, processes and support to deliver quality products and aftersales service precisely, reliably, in full and on time, anywhere.

For further information www.imi-precision.com

Partnerships & problem solving

3

How we deliver value to our customers

We get closer to our customers to understand their exact challenges


Our market leading product brands The combination of our IMI Precision Engineering product brands’ trusted reputation and long history underpins our position as a leading global supplier of motion and fluid control technologies. IMI Precision Engineering has a long experience and reputation in providing oil, gas and chemical solutions. > Proven in safety > Proven in reliability > Proven in durability against the harshest weather conditions and environments > Proven in knowledge

4

For further information www.imi-precision.com

With over 80 years industry experience, the IMI Norgren brand includes a wide range of high quality pneumatic and fluid control products such as actuators, air preparation products, pressure switches, fittings and valves.

Successful in the market for over 80 years, IMI Buschjost is a market leading range of process and multimedia solenoid valve technology and system solutions.

For over 50 years the IMI Herion brand has specialised in solenoid valves, NAMUR valves and hydraulic solutions for mechanical and pneumatic press and press safety technology.

Proven in the field for over 50 years, the IMI Maxseal brand offers extremely high quality stainless steel solenoid valves, for harsh environments such as offshore oil & gas and coastal applications.


New online services To improve your experience, we have introduced a range of web services, including a dedicated and intuitive competitor conversion tool, a new mobile website, and we have also introduced a new product configurator with improved CAD capabilities. We’re engineering GREAT access to our products and services to help you save time and work more efficiently.

Part Converter Looking for an IMI Precision Engineering alternative to competitor parts? Fully Compatible

Try our new Part Converter. All you need is a full or partial part number to find the IMI Precision Engineering alternative. It tells you everything you need to know, including technical details and whether it’s an exact or partial match. To make things even easier, you can link straight through to the recommended alternative, review the technical detail and buy it there and then.

Configuration and CAD

Mobile

For further information www.imi-precision.com

Complete with images and technical information, our new mobile website gives you all the product details you will need to purchase, even out on the factory floor.

5

Our new mobile website lets you purchase products straight from your mobile phone or tablet, wherever you are!

Quickly and easily configure pneumatic cylinders, including the addition of mountings and accessories. It provides price and availability throughout the configuration process and the option to download a CAD file or purchase the completed configuration.


Our global reach With established manufacturing facilities globally, we have the capability to cope with the most demanding of international projects. With a sales and service network in 75 countries, we have the reach and capability to ensure continuity of supply and local support where it is needed.

North America

UK Fradley, Bristol, Leeds & Poole

6

USA Seattle

For further information www.imi-precision.com

USA Littleton

GERMANY Alpen

MEXICO QuerĂŠtaro

South America BRAZIL Sao Paulo

Europe


CZECH REPUBLIC Brno

Africa

INDIA Noida

Australia

Sales & Service in 75 countries IMI Precision Engineering sales, manufacturing and technical centres IMI Precision Engineering sales locations IMI Precision Engineering manufacturing locations

For further information www.imi-precision.com

CHINA Shanghai

7

Asia


8

For further information www.imi-precision.com

Setting the standard for safety, reliability and performance IMI Precision Engineering products are designed to work effectively in aggressive environments and extreme temperatures and meet international standards such as:

Approved

> ATEX

> KOSHA

> TĂœV

> DVGW

> TR-CU

> FM AND UL

> INMETRO

> NEMA

> CSA

> ITRI

> CCOE

DIN EN 61508 IEC 61508


9

Plants supplying products to the energy industries apply Quality Management Systems (QS 9000, VDA 6.1, ISO/TS 16949, ISO 9001, OHSAS 18001) as well as Environmental Management Systems to ISO 14001.

IMI Precision Engineering has a wide portfolio of products, specially designed for the demanding conditions and applications that the oil and gas, chemical, nuclear and power sectors require: >> Aggressive environments a wide range of products rated IP66 and above, in highly resistant materials that offer durability to off-shore salt spray. >> Extreme temperatures Meeting the harshest temperature needs, from -60°C to +200°C.

For further information www.imi-precision.com

Our work with leading national and international oil and gas companies and global suppliers in the Energy Sector means that we talk our customers’ language, and can bring specialised experience about legislation, standards and specifications.


ATEX Solutions Your Reliable Partner for Maximum Explosion Protection 10

For further information www.imi-precision.com

In addition to Directive 2014/34/ EU, which is concerned with the requirements of equipment and protective systems another directive – 1999/92/EC exists. This is concerned with the requirements for the erection, installation and operation of systems.

In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonised in 1975 with the European Frame Directive 76/117/ EEC. The EC-Directive 94/9/EG was valid from 1994 until 2016 and was replaced through the new EU-Directive 2014/34/ EU. This Directive is widely known as

“ATEX” – which derives from the original working title “ATmosphère EXplosible”.

How can explosions occur?

Typical sources of Ignition

>> Adiabatic Compression

>> Hot Surfaces

>> Electro-Magnetic Radiation

>> Flames and Hot Gases

>> Ionising Radiation

>> Mechanically Generated Sparks

>> Chemical Reactions

>> Electrically Generated Sparks

>> Ultra-sound

>> Electro-statically Generated Sparks

>> Flashes

Explosive atmospheres (Ex areas) are prerequisite for an explosion and can be found where a mixture of air, flammable gases, vapours or dusts are being produced, transformed or stored in the presence of oxygen.

ATEX Directive 94/9/EC expands earlier guidelines by including non-electric components such as pneumatic actuators. These now have to be certified.

How can an explosion be prevented? Most important is the prevention of the formation of an explosive atmosphere. If this is not possible, potential sources of ignition must be avoided. Ignition protection categories For electrical equipment for use with gases, vapours and mists special design methods are described in comprehensive works standards and are assigned to

“ignition protection categories”. Several ignition protection categories can be combined in one unit. The methods of protection with explosive dusts concentrates mainly on the sealing of the housing (IP protection). Principles and requirements for nonelectrical equipment for use in explosive areas are described in the new EN 13463-1.

Measures that can be taken to reliably exclude potential sources of ignition, depend upon the equipment category required. In the foreground is usually the consideration of the permissible light metal alloys, electrostatic charge, possible sparks caused by impact or friction and heat due to friction.


Which certificates are required?

These Declarations of Conformity are also obligatory for non-electrical equipment. However, if the risk analysis of explosion hazards show that no potential sources

of ignition exist, the item does not fall under the ATEX directive in which case a Declaration of Conformity and Ex marking is not required. This may apply to products used in purely pneumatic systems, i.e. for valves, service units, sound absorbers.

Figure 1 EU Declaration of Conformity for valve solenoids Figure 2 EC-Type examination certificate for a solenoid valve series Figure 3 Certificate for the Quality Assurance System

Figure 1

Figure 2

Figure 3

Prevent explosions with IMI Precision Engineering ATEX approved equipment As a manufacturer of pneumatic equipment, IMI Precision Engineering offers an extensive range of certified devices in Categories 1, 2 and 3 for use in areas with potentially explosive atmospheres containing gases and dusts:

>> Solenoid valves, solenoids (Type of protection Ex m, Ex me, Ex md,Ex d, Ex ia, Ex nA) >> Pressure switches (Type of protection Ex de, Ex nAC)

>> Valves, cylinders, (Type of protection Ex c)

For further information www.imi-precision.com

For electrical equipment in Category 1 and 2, an EU Type Examination Certificate

issued by a notified body is required. For non electrical equipment an EU Type Examination Certificate is only required for Category 1.

11

A Declaration of Conformity must be provided by the manufacturer for each product. The Declaration of Conformity explains how the manufacturer fulfils all the relevant safety requirements. The CE mark is subsequently attached to the product.


Marking of solenoid valves in potentially explosive atmospheres CONDITIONS IN HAZARDOUS AREAS

FLAMMABLE SUBSTANCES

gases, vapours

dusts

TEMPORARY BEHAVIOUR OF FLAMMABLE SUBSTANCES IN HAZARDOUS PLACES

SUBDIVISION OF HAZARDOUS PLACES

is present continuously or for long periods or frequently

REQUIRED MARKING FOR INSTALLATION CLASSIFICATION OF HAZARDOUS AREAS

EQUIPMENT CATEGORY

EQUIPMENT PROTECTION LEVEL (EPL)

zone 0

II

1G

Ga

is likely to occur in normal operation occasionally

zone 1

II

2G or 1G

Gb or Ga

is not likely to occur in normal operation but, if it does occur, will persist for a short period only

zone 2

II

3G or 2G or 1G

Gc or Gb or GA

is present continuously or for long periods or frequently

zone 20

II

1D

Da

is likely to occur in normal operation occasionally

zone 21

II

2D or 1D

Db or Da

is not likely to occur in normal operation but, if it does occur, will persist for a short period only

zone 22

II

3D or 2D or 1D

Dc or Db or Da

12

5 0123 x II 2G Ex ia IIC T6 Gb PTB 07 ATEX 2019 X

For further information www.imi-precision.com

TYPE OF PROTECTION

PRINCIPLE OF PROTECTION

APPLICATION

MARKING

MAY BE USED IN ZONE

IEC

CENELEC

general requirements

all applications

IEC 60079-0

EN 60079-0

flameproof enclosure

a propagation of an explosion inside to the outside is excluded

control stations, motors, fuses, switchgear, power electronics

Ex d

1 or 2

IEC 60079-1

EN 60079-1

increased safety

avoidance of arcs, sparks and excessive temperature

installation materials, motors, luminaries

Ex e

1 or 2

IEC 60079-7

EN 60079-7

limitation of energy and through that prevention of ignitable sparks

measurement and control, automation technology, sensors, actuators

Ex ia

0, 1 or 2

IEC 60079-11

EN 60079-11

intrinsic safety

Ex ib

1 or 2

IEC 60079-11

EN 60079-11

pressurisation

ex-atmosphere can‘t enter through the overpressure

switch- and control cupboards, analyse-apparatus, computers

Ex p

1 or 2

IEC 60079-2

EN 60079-2

encapsulation

ex-atmosphere can‘t enter through the potting material

coils of motors or relays, solenoid valves

1 or 2

IEC 60079-18

EN 60079-18

oil immersion

ex-atmosphere can‘t enter through the oil

transformers, relays, control stations, magnetic contactors

Ex o

1 or 2

IEC 60079-6

EN 60079-6

powder filling

an propagation of an ignition inside to the outside is excluded

capacitors, transformers

Ex q

1 or 2

IEC 60079-5

EN 60079-5

non sparking

avoidance of ignitable sparks in normal operation

sensors, solenoids, pressure switches

Ex n

2

IEC 60079-15

EN 60079-15

Ex ma Ex mb


EXPLOSION GROUP

TEMPERATURE CLASS (GASES)

MARKING

EXAMPLE

PERMISSIBLE EQUIPMENT GROUP

IIA

propane

IIA or IIB or IIC

IIB

ethylene

IIB or IIC

IIC

hydrogen

IIC

TEMPERATURE CLASS (GASES)

MAX. SURFACE TEMPERATURE OF THE EQUIPMENT

PERMISSIBLE TEMPERATURE CLASSES OF THE EQUIPMENT

EXAMPLE

T1

450°C

T1 to T6

town gas

T2

300°C

T2 to T6

ethylene

T3

200°C

T3 to T6

gasoline fuels

T4

135°C

T4 to T6

acetaldehyde

T5

100°C

T5 to T6

T6

85°C

T6

carbon disulfide

5 0123 x II 2G Ex ia IIC T6 Gb TUV PTB 07 ATEX 2019 X NOTIFIED BODY FOR THE EQUIPMENT APPROVAL

CODE NUMBER

COUNTRY

TÜV

0044

Germany

REQUIREMENTS

MARKING

INERIS

0080

France

without restriction

Physikalisch Technische Bundesanstalt

PTB

0102

Germany

special condition should be noted

X

TÜV SÜD Product Service GmbH

TPS

0123

Germany

DEKRA EXAM GmbH

BVS

0158

Germany

DEKRA/KEMA

0344

Netherlands

SIRA

0518

UK

BASEEFA

1180

UK

TÜV NORD CERT GmbH INSTITU NATIONAL DE L´ENVIRONNEMENT INDUSTRIEL ET DES RISQUES

SIRA CERTIFICATION SERVICE SGS BASEEFA LIMITED

Ex-component, which is not intended to be used alone and requires additional certification. U

CE-Conformity is declared by the manufacturer if the part is fitted into a complete equipment.

In dust atmospheres

II 2D Ex tb IIIC T 90°C Db TYPE OF PROTECTION

MARKING

MAY BE USED IN ZONE

STANDARD

Flameproof enclosures

Ex d

1 or 2

IEC EN 60079-1

Increased safety

Ex e

1 or 2

IEC EN 60079-7

Ex ia

0 or 1 or 2or 20 or 21 or 22

Ex ib

1 or 2 or 21 or 22

Ex ic

2 or 22

Ex ma

0 or 1 or 2or 20 or 21 or 22

Ex mb

1 or 2 or 21 or 22

Ex mc

2 or 22

Ex n

2 or 22

Ex ta

20 or 21 or 22

Ex tb

21 or 22

Ex tc

22

Intrinsic safety

Encapsulation

„n“ type of protection

Protection by enclosure

IEC EN 60079-11

Max. surface temperature of the equipment

EXPLOSION GROUP (DUSTS) MARKING

Type of Dust

Example

Permissible equipment group

IIIA

Combustible flyings

Cotton

IIIA or IIIB or IIIC

IIIB

Non-conductive dust

Grain

IIB or IIIC

IIIC

Conductive dust

Aluminium dust

IIIC

IEC EN 60079-18

IEC EN 60079-15

IEC EN 60079-31

For further information www.imi-precision.com

DEKRA Certification B.V.

RESTRICTION FOR USING APPARATUS

13

SHORT NAME


14


1 Valves

NAMURInterface

Suited for outdoor applications

Universal flow direction

Flange version


13 mm

6215M NAMUR & Inline G1/4,1/4 NPT 2.5 … 8 bar

13 mm

6215M NAMUR & Inline G1/4,1/4 NPT 2.5 … 8 bar

16 mm

24011 NAMUR & Inline G1/4, 1/4 NPT 0 … 10 bar

16 mm

24010 NAMUR & Inline G1/4, 1/4 NPT 0 … 10 bar

Direct

16 mm

98015 NAMUR & Inline G1/4, 1/4NPT, G1/2, 1/2 NPT 0 … 10 bar

Direct

30.5; 38.5; 47.5 Depends of solenoids

21000 G1/2 up to 50 bar max.

Direct

30.5; 38.5; 47.5 Depends of solenoids

23200 G1/2, G1 up to 100 bar max.

30.5; 38.5; 47.5 Depends of solenoids

24000 G1/4, G1/2 up to 100 bar max.

Indirect Indirect Indirect Indirect Indirect Indirect Indirect Indirect Direct Direct Direct

For further information www.imi-precision.com

Direct

Direct

16

95000 Inline G1/4, 1/4 NPT, G1/2 up to 40 bar max.

96000 Inline G1/4, 1/4 NPT up to 10 bar max.

6316 Inline G1/4,1/4 NPT 0 … 8 bar

SIL Certification (IEC 61508)

M/O with manual override

M/O without manual override

M/O-add-on manual override

Spool valves

Seat valves

NAMUR Flange

Stainless steel

Cast iron

Brass

Black anodised Aluminium

Anodised Aluminium

5/3 All ports blocked

5/2 Impulse

3/2 » 5/2 With adapter plate

5/2 Spring return

3/2

2/2

Solenoid space tube Ø 9 mm 13 mm 13 mm 9 mm 13 mm 13 mm 16 mm

98025 NAMUR & Inline G1/2, 1/2 NPT 2 … 8 bar

13 mm

26360, 80207 Inline G1/4 up to 10 bar max.

13 mm

26360, 80207 NAMUR G1/4 up to 10 bar max.

16 mm

97300 NAMUR G1/4, 1/4 NPT 2 … 8 bar

Indirect

97105 Inline G1/4, 1/4 NPT, G1/2, 1/2 NPT 2.5 … 8 bar

Zone 1, 2 II2G

NEMA

Solenoid - Model Power consumption

Solenoid - Model Power consumption

3039

382x

Solenoid - Model Power consumption

Solenoid - Model Power consumption

Solenoid - Model Power consumption

Solenoid - Model Power consumption

Solenoid - Model Power consumption

Solenoid - Model Power consumption

13xx, 150x, 16xx

144x, 157x

42xx

46xx

2003 & 205x

48xx

3039 37 mA II 2G Ex ia IIC T4/ T6 Gb II 2D Ex ia IIIC T80°C Db II 2D Ex ia IIIC T100°C Db

3034 0,7 W

3050 1,8 W

3034 2,0 VA 4200 0,8 W; 4201 1,3 VA II 2G Ex eb mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

4600/4602 0,8 W; 4601/4603 1,3 VA II 2G Ex d mb IIC T5/T6 Gb II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

2050 … 2053 II 2G Ex ia IIC T4/ T6 Gb II 2D Ex ia IIIC T80°C Db II 2D Ex ia IIIC T100°C Db

4802 0,8 W; 4803 1,3 VA III 2G Ex mb d IIC T4/T6 II 2G Ex mb e IIC T4/T6

4200 0,8 W; 4201 1,3 VA II 2G Ex eb mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

4600/4602 0,8 W; 4601/4603 1,3 VA II 2G Ex d mb IIC T5/T6 Gb II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

2050 … 2053 II 2G Ex ia IIC T4/ T6 Gb II 2D Ex ia IIIC T80°C Db II 2D Ex ia IIIC T100°C Db

4802 0,8 W; 4803 1,3 VA II 2G Ex mb d IIC T4/T6 II 2G Ex mb e IIC T4/T6

4210 3,9 W; 4211 5,3 VA II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

4610/4612 3,9 W; 4611/4613 5,3 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

4210 3,9 W; 4211 5,3 VA II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

4610/4612 3,9 W; 4611/4613 5,3 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

0763 2,1 VA

4200 0,8 W; 4201 1,3 VA II 2G Ex eb mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

4600/4602 0,8 W; 4601/4603 1,3 VA II 2G Ex d mb IIC T5/T6 Gb II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

0827 6,8 W 0800 16,9 W 3805 10,6 VA 3803 19,5 VA

4260 3,9 W/4270 8,9 W 4261 5,3 VA/4271 10,0 VA II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

4660/4662 3,9 W; 4670/4672 8,9 W 4661/4663 5,3 VA; 4671/4673 10,0 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

0763 1,9 W 0763 2,1 VA 0763 1,9 W 0763 2,1 VA

1

3036 1,6 W

3050 1,8 W

3036 3,5 VA 0242 2,7 W 0245 4,2 VA 0242 2,7 W 0245 4,2 VA 0763 1,9 W

4872 8,9 W; 4873 10,0 VA II 2G Ex mb d IIC T4/T6 II 2G Ex mb e IIC T4/T6 2003 II 2G Ex ia IIC T5/T6 II 2D Ex tD A21 IP66 T95°C

0800 16,9 W

4270 8,9 W; 4271 10,0 VA II 2G Ex eb mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db IP66

3803 19,5 VA

0246 8,0 W 0200 12,1 W

0700 16,9 W 0800 16,9 W

3206 9,2 VA 3204 11,3 VA

3703 19,5 VA 3803 19,5 VA

0246 8,0 W 3206 9,2 VA

1300 21,4 W; 1500 38,7 W 1301 22,8 VA; 1501 42,1 VA

1300 21,4 W; 1500 38,7 W 1600 52,3 W 1301 22,8 VA; 1501 42,1 VA 1601 56,4 VA

1300 21,4 W; 1500 38,7 W 1301 22,8 VA; 1501 42,1 VA

4670/4672 8,9 W; 4671/4673 10,0 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

1440 21,4 W; 1570 38,7 W 1441 22,8 VA; 1571 42,1 VA 1440 & 1441: II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T120°C Db IP65 1570 & 1571: II 2G Ex e mb IIC T4 Gb 1440 21,4 W; 1570 38,7 W 1441 22,8 VA; 1571 42,1 VA 1440 & 1441: II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T120°C Db IP65 1570 & 1571: II 2G Ex e mb IIC T4 Gb 1440 21,4 W; 1570 38,7 W 1441 22,8 VA; 1571 42,1 VA 1440 & 1441: II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T120°C Db IP65 1570 & 1571: II 2G Ex e mb IIC T4 Gb

1570 38,7 W 1571 42,1 VA II 2G Ex e mb IIC T4 Gb

4210 3,9 W/4211 5,3 VA II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db 4220 8,9 W/4221 10,0 VA 4230 11,4 W/4280 11,4 W 4231 15,2 VA/4281 15,2 VA II 2G Ex eb mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db 4210 3,9 W; 4211 5,3 VA II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

4610/4612 3,9 W; 4620/4622 8,9 W 4611/4613 5,3 VA; 4621/4623 10,0 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db 4630/4632 11,4 W; 4680/4682 11,4 W 4631/4633 15,2 VA; 4681/4683 15,2 VA II 2G Ex d mb IIC T4/T5 Gb II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db 4610/4612 3,9 W; 4611/4613 5,3 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

4872 8,9 W; 4873 10,0 VA II 2G Ex mb d IIC T4/T6 II 2G Ex mb e IIC T4/T6

3824 8,9 W; 3826 13,6 W 3825 9,5 VA; 3827 15,7 VA Cl. I, Div. 1, Gr. A - D Cl. II/III, Div. 1, Gr. E - G T3C (160°C) NEMA 4X

For further information www.imi-precision.com

97105 NAMUR G1/4, 1/4 NPT, G1/2, 1/2 NPT 2.5 … 8 bar

Solenoid - Model Solenoid - Model Solenoid - Model Solenoid - Model Power Power Power Power consumption consumption consumption consumption 07xx/08xx/ 305x 02xx 3803/3805 303x

II2G

18

97100 Inline G1/4, 1/4 NPT 2 … 8 bar

Zone 1, 2, 21, 22 II 2G / II 2D

II 2G / II 2D

VALVES

VALVES

Actuated

IP65

Direct

1

Product Selector


Zone 1, 2, 21, 22

SIL Certification (IEC 61508)

M/Owith manual override

M/Owithout manual override

M/Oadd-on manual override

Stainless steel

Cast iron

Brass

2/2

8171

840x / 940x

Indirect actuated

9101 8,0 W 9151 18,0 W 9101 15,0 VA 9151 45,0 VA

Direct actuated Indirect actuated Pneumatically actuated Direct actuated Pneumatically actuated

84500 ASPV G1/2 … G2 up to 25 bar

84520 ASPV G1/2 … G2 up to 25 bar

9191

6120 18 W 6126 14 W 6120 20 VA 6126 16 VA Ex eb mb IIC T4 Gb Ex eb mb IIC T3 Gb Ex mb tb IIIB Ex mb tb IIIB T125°C Db T140°C Db

9186 14,0 W 9186 16,0 VA Ex em II T4 T140°C

9191 18,0 W 9191 20,0 VA Ex em II T3 T140°C

6120 18 W 6126 14 W 6120 20 VA 6126 16 VA Ex eb mb IIC T4 Gb Ex eb mb IIC T3 Gb Ex mb tb IIIB Ex mb tb IIIB T125°C Db T140°C Db

9186 14,0 W 9186 16,0 VA Ex em II T4 T140°C

9191 18,0 W 9191 20,0 VA Ex em II T3 T140°C

6176

6246

6240

6106

8186

84xx

8920

6106 8 W 6106 9 VA Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db

9136

9136 8,0 W 9136 9,0 VA Ex m II T4 T130°C

9136 8,0 W 9136 9,0 VA Ex m II T4 T130°C

46xx 4670 9,0 W II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db 4680 10,0 W II 2G Ex d mb IIC T4/T5 Gb II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

382x

4670 9,0 W II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db 4680 10,0 W II 2G Ex d mb IIC T4/T5 Gb II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

3826 13,6 W 3827 15,7 VA Cl. I, Div. 1, Gr. A,B, C, D Cl. II/III, Div. 1, Gr. E, F, G T3C (160°C) NEMA 4X

1

3826 13,6 W 3827 15,7 VA Cl. I, Div. 1, Gr. A,B, C, D Cl. II/III, Div. 1, Gr. E, F, G T3C (160°C) NEMA 4X

9401 38,0 W

9151 18,0 W

9404 42,0 VA

9154 20,0 VA

9401 38,0 W

9151 18,0 W

9404 42,0 VA

9154 20,0 VA

6120 18 W 6120 20 VA Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db

9191 18,0 W 9191 20,0 VA Ex em II T3 T140°C

6120 18 W 6120 20 VA Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db

9191 18,0 W 9191 20,0 VA Ex em II T3 T140°C

6176 9 W 6176 10 VA Ex eb mb IIC T4 Gb Ex mb tb IIIB T135°C Db

8171 12,0 W 8171 23,0 VA

9401 38,0 W 8401 40,0 W 9404 42,0 VA 8404 45,0 VA 9401 38,0 W 8401 40,0 W 9404 42,0 VA 8404 45,0 VA

8401 40,0 W

9501 80,0 W

8404 45,0 VA

9504 89,0 VA

8186 9,0 W 8186 10,0 VA Ex em II T4 T140°C

6246 14 W 6246 16 VA Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db

6240 18 W 6240 20 VA Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db

8436 32,0 W; 8436 36,0 VA Ex em II T4 T140°C 8441 40,0 W; 8441 45,0 VA Ex me II T3 T140°C

8920 29,0 W 8920 33,0 VA Ex d II C T4/T5 T130°C/T95°C

6246 14 W 6246 16 VA Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db

6240 18 W 6240 20 VA Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db

8436 32,0 W; 8436 36,0 VA Ex em II T4 T140°C 8441 40,0 W; 8441 45,0 VA Ex me II T3 T140°C

8920 29,0 W 8920 33,0 VA Ex d II C T4/T5 T130°C/T95°C

6246 14 W 6246 16 VA Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db

6240 18 W 6240 20 VA Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db

8436 32,0 W; 8436 36,0 VA Ex em II T4 T140°C 8441 40,0 W; 8441 45,0 VA Ex me II T3 T140°C

8920 29,0 W 8920 33,0 VA Ex d II C T4/T5 T130°C/T95°C

For further information www.imi-precision.com

For further information www.imi-precision.com

85780 with forced lifting flange version 0 … 25 bar

9186

NEMA

21

19

82590 with forced lifting G1/4 … G1 up to 10 bar

85540 with forced lifting flange version 0 … 25 bar

6120

II 2G/II 2D

9101 15,0 VA

82540 with forced lifting G1/4 … G1 up to 10 bar

85500 with forced lifting flange version 0 … 25 bar

6126

II 2GD

9101 8,0 W

82470 Differential pressure G1/4 … G1 up to 10 bar

82900 High flow G3/4 … G1, 3/4 NPT … 1 NPT 0.4 … 8 bar

950x

9101 15,0 VA 9151 45,0 VA

82730 Differential pressure G1/4 … G1 up to 16 bar

82960 High flow G3/4 … G3, 3/4 NPT … 2 1/2 NPT 0.4 … 8 bar

91xx 9101 8,0 W 9151 18,0 W

82400 Differential pressure G1/4 … G2 up to 16 bar

Zone 1, 2, 21, 22

II 2G

VALVES

VALVES

Aluminium

IP65

Function

1

Product Selector


1

Fast Find Guide

VALVES

IMI Herion valves - Removable solenoids NAMUR & Inline - Solenoid operated valves, indirect actuated 97100 Inline

97105 Inline

3/2, 5/2, 5/3 1/4”

2 … 8 bar ALU

97105 NAMUR

3/2, 5/2, 5/3 1/4”, 1/2”

Page 24

2,5 … 8 bar ANO, SS

Page 25

98025 NAMUR & Inline

6215M NAMUR & Inline

2 … 8 bar ANO

ANO

3/2 1/2”

Page 33

97300 NAMUR

3/2, 5/2, 5/3 1/4”, 1/2”

2,5 … 8 bar ANO, SS

3/2, 5/2 1/4”

Page 26

2 … 8 bar ALU

26360 & 80207 Inline

26360 & 80207 NAMUR

1 … 10 bar ALU

1 … 10 bar ALU

3/2, 5/2 1/4”, 1/2”

Page 29

Page 30

3/2, 5/2 1/4”

Page 31

6215L NAMUR & Inline

3/2,5/2 1/4”

3/2,5/2 1/4”

Page 35

Page 37

ANO

NAMUR & Inline - Solenoid operated valves, direct actuated 24011 NAMUR & Inline

24010 NAMUR & Inline

98015 NAMUR & Inline

21000

0 … 10 bar ANO, BR, SS

0 … 10 bar ANO, BR, SS

0 … 10 bar ANO, BR, SS

0 … 50 bar BR

3/2 1/4”

22

Page 39

95000

3/2 1/4”, 1/2”

Page 43

96000

2/2 1/4”, 1/2”

For further information www.imi-precision.com

0 … 40 bar BR

3/2 (Ex ia) 1/4”

0 … 10 bar BR

Page 44

24000

2/2 G1/2”, G 1"

Page 46

3/2 1/4”, 1/2”

0 … 50 bar BR

Page 47

0 … 100 bar BR

Page 48

6316 Inline

3/2 1/4"

Page 50

23200

2/2 1/2"

3/2 1/4"

Page 51

ANO, BR, SS

Page 56

IMI Maxseal valves - Integrated solenoids - ATEX Zone 0 ICO3S EX IA - direct actuated YX1 Inline 3/2, 5/2 1/4”

0 … 12 bar SS

Page 57

IMI Maxseal valves - Integrated solenoids - ATEX Zone 1 ICO3S - Direct actuated ICO4S - Direct actuated ICO4-PST - Electromagnetic actuated Y01 Inline

Y1 Inline

3/2, 5/2 1/4”, 1/2”

0 … 12 bar SS

ALU

Y41 Poppet valve

3/2, 5/2 1/4”, 1/2”

0 … 20 bar SS

Page 58

Anodised Aluminium

3/2 1/4” … 3/4”

ANO

Black anodised Aluminium

BR

0 … 10 bar SS

Page 59

Brass

SS

Stainless Steel

CAS

Cast iron

Page 63

CAI

Casting stainless steel


Fast Find Guide

1

82400 82730

82470

82540 82590

2/2 1/4 … 1"

2/2 1/4 … 2"

0,1 … 16 bar BR, SS

Page 64

0,1 … 10 bar BR

82960, 82970

Page 66

82900, 82910

2/2 3/4” … 3”

2/2 1/4 … 2"

0 … 10/16 bar BR, SS

Page 67

VALVES

IMI Buschjost diaphragm valves 2/2 3/4 … 1"

0,4 … 8 bar ALU

Page 68

0,4 … 8 bar ALU

Page 69

IMI Buschjost piston seat valves 85500

85540

2/2 Flange version

85780

2/2 Flange version

0 … 25 bar CAS, BR

Page 70

0 … 25 bar SS

2/2 Flange version

Page 70

0 … 25 bar SS

Page 71

IMI Buschjost angle seat pilot valves 23

84500 84520

2/2 1/2 … 2"

Page 72

For further information www.imi-precision.com

0 … 10/16 bar BR, SS

Redundant valve manifolds - 1oo2, 2oo2, 2oo3 V81 - IMI Herion Modular with Bypass

V82 - IMI Herion Compact

0 … 10 bar AA, SS

0 … 0 bar AA, SS

1/4", 1/2"

Page 73

1/4", 1/2"

V83 - IMI Maxseal Modular with Bypass

V84 - IMI Maxseal Compact

0 … 10 bar AA, SS

0 … 12 bar AA, SS

1/4", 1/2"

Page 73

1/4", 1/2"

Page 73

Page 73

IMI Herion Boosters Inline - Pneumatically actuated valves 80400

3/2 1/2” … 1 1/2”

0 … 10 bar SS

ALU

Page 77

Anodised Aluminium

ANO

Black anodised Aluminium

BR

Brass

SS

Stainless Steel

CAS

Cast iron

CAI

Casting stainless steel


1

97100 Inline

VALVES

• 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled • G1/4, 1/4 NPT The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category 2of solenoids(see table of solenoids).

V-32C-EM-S

1

3 4

2

4 3 4

1 2 1

Medium: Filtered, non-lubricated or dry compressed air Operating pressure: 2 … 8 bar (29 … 116 psi) Fluid/Ambient temperature: -15°C … +60°C (-5°F … 140°F) Depending on solenoid system.

Materials: Housing: Anodized Aluminium Pilot flange: Plastic (PBT) Seals: NBR

Approved

Approval depends on magnetic system

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

V-52-EM-S

2 513 Technical data

Symbol

Manual override with detent standard

Technical features

2 2

54 1 51 4 3 5 41

3 2 3 2 32

54 1 51 4 51

2 3 3 2 3

V-32C-EMH-S Model *1) V-52B-EM V-52-EMH-S 9713032 V-32C-EMH-S 9713042 V-53A-EM

513 4 2

Port size

Function

Actuation/Return

Operating pressure (bar)

Flow (l/min)

G1/4

3/2

Solenoid/air spring

2…8

750

1/4 NPT

3/2

Solenoid/air spring

2…8

750

V-52B-EMH 9710032 V-52-EMH-S 9710042 V-53A-EMH 9711032 V-52B-EMR 9711042

G1/4

5/2

Solenoid/air spring

2…8

750

1/4 NPT

5/2

Solenoid/air spring

2…8

750

G1/4

5/2

Solenoid/Solenoid

2…8

750

1/4 NPT

5/2

Solenoid/Solenoid

2…8

750

9712032 V-53A-EMR 9712042

G1/4

5/3 APB

Solenoid/Solenoid

2…8

500

1/4 NPT

5/3 APB

Solenoid/Solenoid

2…8

500

513

*1) When ordering, please indicate solenoid, voltage and current (frequency). Valve function: APB = All Ports Blocked.

24

Solenoid Model

For further information www.imi-precision.com

3050

Power consumption 24 V DC 230 V AC (W) (VA) 1,8 –

Rated current 24 V DC (mA) 70

230 V AC (mA) –

IP-Protection

Ex-Protection (ATEX-Category)

Temperature Ambient/ Medium (°C)

IP65 (Connector DIN EN 175301-803, Form B) *2)

-15 … +50

3034

0,7

2,0 *3)

29

4

IP65 (Connector DIN EN 175301-803, Form B) *2)

-15 … +50

3062

2,7

115

IP65 (with 3 m cable)

II 2G Ex mb IIC T5 Gb II 2D Ex mb tb IIIC T95°C Db

-20 … +50

3063

2,1

9

IP65 (with 3 m cable)

II 2G Ex mb IIC T5 Gb II 2D Ex mb tb IIIC T95°C Db

-20 … +50

Standardvoltages 24 V d.c., 230 V a.c., other voltages on request. *2) Connector is not scope of delivery, see table »Accessories«.

*3) Valves can be operated with DC only. For 230V AC application please use 206V DC coil together with recifier plug 0663303.

For intrinsically safe circuits, Protection class II 2G Ex ia IIC T4/T6 Ga Model

Nominal resistance RN Coil (Ω)

Required switching min. Current min (mA)

Rated currentIon RW 50 Coil (Ω)

Required switching at terminal RW 50 (V)

Temperature Ambient/Medium (°C)

3039 *4)

275

37

345

13,8

T6: -40 … +50 T4: -40 … +85

When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken in account.

On the other hand, the low effective inductivity and capacity can be ignored. *4) Connector not supplied, required connector: model 0570275.

Accessories Connector DIN EN 175301-803

Approvals Silencer (plastic) *5)

Silencer (stainless steel) *5)

0570275, Form A

M/S2 (G1/4)

0014613 (G1/4)

0663303, Form A (with rectifier)

C/S2 (1/4NPT)

0613678 (1/4 NPT)

0680003, Form B

Exhaust guard *6)

Model

Approvals ATEX FM

306x

PTB 03 ATEX 2015 X

3039

PTB 03 ATEX 2134

CSA-LR 51090-4

0613422 (1/4")

*5) For indoors use only. *6) For outdoors use ~ 0,2 (bar).


97105 Inline Technical features

• G1/4, 1/4 NPT, G1/2, 1/2 NPT The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Medium: Filtered, non-lubricated and dried compressed air, instrument air, nitrogen and other non-flammable neutral, dry fluids Operating pressure: 2,5 … 8 bar (36 … 116 psi) with internal air supply 0 … 8 bar (0 … 116 psi) with external air supply Fluid/Ambient temperature: -40°C … +65°C (NBR)(-40°F … +149°F) -25°C … +80°C (HNBR)(-13°F … +176°F) Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP66 protection must be used! Materials: Body: Aluminium with surface treatment for rough environmantal conditions. ( Stainless steel DIN 50018: Condensate test with alternating temperatures in sulphuric atmosphere, DIN 50021/ASTM B117-73: Salt spray test with different sodium chloride solutions, tested in ammonia atmosphere). Stainless steel 1.4404 (316 L) Seals: NBR or HNBR

VALVES

• 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled

1

Add-on manual override

SIL2 @ HFT=0 SIL3 @ HFT=1

Approved

Approval depends on magnetic system

Technical data NBR: -40°C … +65°C / IEC 61508: -40°C … +40°C Symbol

2

Function

Actuation/Return

Operating pressure (bar)

Flow (l/min)

Test certificate IEC 61508

9713535

G1/4

3/2

Solenoid/Spring

2,5 … 8

1300

x

9713545

1/4 NPT

3/2

Solenoid/Spring

2,5 … 8

1300

x

9713555

G1/2

3/2

Solenoid/Spring

2,5 … 8

2600

-

9713565

1/2 NPT

3/2

Solenoid/Spring

2,5 … 8

2600

-

9710535

G1/4

5/2

Solenoid/Spring

2,5 … 8

1300

x

9710545

1/4 NPT

5/2

Solenoid/Spring

2,5 … 8

1300

x

9710555

G1/2

5/2

Solenoid/Spring

2,5 … 8

2600

-

9710565

1/2 NPT

5/2

Solenoid/Spring

2,5 … 8

2600

-

9711535

G1/4

5/2

Solenoid/Solenoid

2,5 … 8

1300

-

1/4 NPT

5/2

Solenoid/Solenoid

2,5 … 8

1300

-

G1/4

5/3 APB

Solenoid/Solenoid

2,5 … 8

950

-

5/3 APB

Solenoid/Solenoid

2,5 … 8

950

-

Port size

Function

Actuation/Return

Operating pressure (bar)

Flow (l/min)

Test certificate IEC 61508

G1/4

3/2

Solenoid/Spring

2,5 … 8

1300

x

V-32C-EM-F 1

3 2 4

1

V-32C-EMH-F

2

V-52-EM-F

3 2

1

513 4 4 3

2 2

51 51 4 4 4

3 3 22 2

V-32C-EMR-F

V-52-EMH-F V-52B-EM 9711545 9712535

V-52-EMH-F V-53A-EM 1/4 NPT 9712545 V-52B-EMH

5 51 13 3 513

*1) When ordering please indicate solenoid, voltage and current type (frequency).

4 4

2 2

V-53A-EMH V-52B-EMR

513 NBR: -40°C … +65°C 5 1 3 / IEC 61508: -40°C … +40°C Symbol

4

Model *1)

2

V-53A-EMR

9713735

513 2

9713745

1/4 NPT

3/2

Solenoid/Spring

2,5 … 8

1300

x

9713755

G1/2

3/2

Solenoid/Spring

2,5 … 8

2600

-

V-32C-EM-F 1

3 2 4

1

513 4 4 3

1/2 NPT

3/2

Solenoid/Spring

2,5 … 8

2600

-

G1/4

5/2

Solenoid/Spring

2,5 … 8

1300

x

V-32C-EMH-F

9710745

1/4 NPT

5/2

Solenoid/Spring

2,5 … 8

1300

x

9710755

G1/2

5/2

Solenoid/Spring

2,5 … 8

2600

-

V-52-EM-F

3 2

1

2

9713765 9710735

2 2

513 513

9710765

1/2 NPT

5/2

Solenoid/Spring

2,5 … 8

2600

-

9711735

G1/4

5/2

Solenoid/Solenoid

2,5 … 8

1300

-

1/4 NPT

5/2

Solenoid/Solenoid

2,5 … 8

1300

-

V-32C-EMR-F

V-52-EMH-F V-52B-EM 9711745

4 solenoid, 2 *1) When ordering please indicate voltage and current type (frequency). 4 2 513 513 4

V-52-EMH-F V-52B-EMH

2

V-52B-EMR

For further information www.imi-precision.com

Port size

25

Model *1)


1

97105 NAMUR

VALVES

• 3/2, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled

Add-on manual override

Technical features

Medium:

• G1/4, 1/4 NPT, G1/2, 1/2 NPT, flanged with NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Filtered, non-lubricated and dried compressed air, instrument air, nitrogen and other non-flammable neutral, dry fluids Operating pressure: 2,5 … 8 (36 … 116 psi) with internal air supply 0 … 8 bar (0 … 116 psi) with external air supply (G1/2, 1/2 NPT or low power pilot system only) Fluid/Ambient temperature: Valve: -40°C … +65°C (NBR) (-40°F … +149°F) -25°C … +80°C (HNBR) (-13°F … +176°F) Depending on solenoid system.

Materials: Body: Aluminium 3.0615 with surface treatment for rough environmantal conditions. Approved according to DIN 50018: Condensate test with alternating temperatures in sulphuric atmosphere, DIN 50021/ ASTM B117-73: Salt spray test with different sodium chloride solutions, tested in ammonia atmosphere). Stainless steel 1.4404 (316 L) Seals: NBR or HNBR SIL2 @ HFT=0 SIL3 @ HFT=1

Approved

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Approval depends on magnetic system

For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP66 protection must be used!

26

Technical data Housing: Aluminium anodized, NBR: -40°C … +65°C / IEC 61508: -40°C … +40°C For further information www.imi-precision.com

Symbol

4

2

4

2

V-32spec-EM-F

4

2

4

2 5 13

4

2

V-32spec-EMH-F

4 2 513

V-32spec-EM-EM 54 1 32

45 13 2

V-32spec-EMR-F

*1) When ordering please (frequency). 4 indicate 2 solenoid, voltage and current type 4 2

5 13

Housing: Symbol

5 13 Stainless 4

513

V-32spec-EMH-EMH

4

2

V-32spec-EMR-EMR 54 1 32

3 45 12

V-32spec-EM-F 44

22 55 11 33

Actuation/Return

Operating pressure (bar)

Flow (l/min)

Test certificate IEC 61508

9710505

G1/4 NAMUR

Solenoid/Spring

2,5 … 8

1300

x

9710515

1/4 NPT NAMUR

Solenoid/Spring

2,5 … 8

1300

x

9710595

G1/2 NAMUR

Solenoid/Spring

2,5 … 8

2600

9710596

1/2 NPT

Solenoid/Spring

2,5 … 8

2600

Solenoid/Solenoid

2,5 … 8

1300

Solenoid/Solenoid

2,5 … 8

1300

Actuation/Return

Operating pressure (bar)

Flow (l/min)

Test certificate IEC 61508

G1/4 NAMUR

Solenoid/Spring

2,5 … 8

1300

x

9710715

1/4 NPT NAMUR

Solenoid/Spring

2,5 … 8

1300

x

9711705

G1/4 NAMUR

Solenoid/Solenoid

2,5 … 8

1300

Solenoid/Solenoid

2,5 … 8

1300

V-52-EMH-F 9711505

G1/4 NAMUR

V-52B-EM 9711515 1/4 NPT NAMUR V-52-EMH-F V-52B-EMH

3 steel, NBR: -40°C 5…1 +65°C / IEC 61508: -40°C … +40°C

2

5 13

Port size

V-52-EM-F 513

5 13

Model *1)

Model *1)

V-52B-EMR 9710705

V-52-EM-F 513 4 4

2 2

V-32spec-EM-EM V-32spec-EMH-F 513

Port size

V-52B-EM V-52-EMH-F 9711715 1/4 NPT NAMUR

*1) When ordering please 4 2 4 indicate 2 solenoid, voltage and current type (frequency).

4

2

5 13 5 13 4

2

4

2

V-32spec-EMH-EMH V-32spec-EMR-F 4

2

V-32spec-EMR-EMR 5 13

V-52B-EMH V-52-EMH-F

5 51 13 3

513

V-52B-EMR


97105 NAMUR & Inline

1

Solenoids

Model

Power consumption

Rated current

Ex-Protection (ATEX-Category)

Temperature Ambient/ Medium (°C)

Electrical connection

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

0763

1,9

2,1

78

11

IP65 (with Connector)

-25 … +60

DIN EN 175 301-803 Form A *2) *3)

4200

0,8

38

IP66 (with cable II 2G Ex eb mb IIC T5/T6 Gb gland) II 2D Ex tb IIIC T130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

M20 x 1,5 *3)

4201

1,3

6

IP66 (with cable II 2G Ex eb mb IIC T5/T6 Gb gland) II 2D Ex tb IIIC T130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

M20 x 1,5 *3)

4600

0,8

33

IP66 (with cable II 2G Ex d mb IIC T5/T6 Gb gland) II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

1/2 NPT *3)

4602

0,8

33

IP66 (with cable II 2G Ex d mb IIC T5/T6 Gb gland) II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

M20 x 1,5 *3)

4601

1,3

6

IP66 (with cable II 2G Ex d mb IIC T5/T6 Gb gland) II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

1/2 NPT *3)

4603

1,3

6

IP66 (with cable II 2G Ex d mb IIC T5/T6 Gb gland) II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

M20 x 1,5 *3)

4802

0,8

33

IP66 (with cable II 2G Ex mb d IIC T4/T6 Gb gland) II 2G Ex mb e IIC T4/T6 Gb

T4: -40 … +50 T6: -40 … +40

M20 x 1,5 *3)

1,3

6

IP66 (with cable II 2G Ex mb d IIC T4/T6 Gb gland) II 2G Ex mb e IIC T4/T6 Gb

T4: -40 … +50 T6: -40 … +40

M20 x 1,5 *3)

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *2) Required connector: model 0570275 for V DC; model 0663303 for V AC, to be ordered Solenoid Voltage 200V DC! *3) Connector cable gland not supplied, see table »Accessories«. Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Approvals Model

Approvals ATEX IECEx

42xx

KEMA 98 ATEX 4452 X

IECEx KEM 09.0068X

46xx

PTB 02 ATEX 2085 X

IECEx PTB 11.0094X

48xx

PTB 06 ATEX 2054 X

IECEx PTB 07.0039X

For further information www.imi-precision.com

4803

27

IP-Protection

VALVES

Solenoids


1

97105 NAMUR & Inline Solenoids and accessories

VALVES

Solenoid actuators for intrinsically-safe circuits Model

Nominalresistance RN coil (Ω)

Min. required switching current (mA)

Resistance RW 60 Coil (Ω)

Required voltageat terminal Rw 60 (V)

2050

200

33

240

8

2051

391

24

460

11

2052

736

17

880

15

2053

1220

13

1460

19

IP-Protection

IP66 (with cable gland)

Ex-Protection (ATEX-Category)

Temperature Ambient/Medium (°C)

II 2G Ex ia IIC T6 Gb II 2G Ex ia IIC T4 Gb II 2D Ex iaD 21 T80°C Db II 2D Ex iaD 21 T100°C Db

T4: -40 … +60 T6: -40 … +80 -40 … +60 -40 … +80

Cable gland (cable Ø 5 … 10 mm) is in scope of delivery. When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken into account. Ui = 45 V Ii = 500 mA according to Tab. A. 1, EN 60079-11. Pi = 2,0 W, Li and Ci can be ignored.

Approvals Model

Approvals ATEX IECEx FM

205x

PTB 07 ATEX 2019 X

IECEx PTB 07.0017

Accessories Cable gland Protection Ex e, Ex d (ATEX)

28

For further information www.imi-precision.com

Model

For solenoid

Thread

Cable Ø (mm)

Material

Protection class (ATEX)

Ambient temperature limitation

0589735

42xx

M20 x 1,5

7,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *4)

0589736

42xx

M20 x 1,5

10,0 … 14,0

Plastic

II 2G Ex e / II 2D Ex t

See table *4)

0589737

42xx

M20 x 1,5

6,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *4)

0588819

46xx

M20 x 1,5

5,0 … 8,0

Nickel plated brass

II 2G Ex e / II 2D Ex t

0588851

46xx

M20 x 1,5

10,0 … 14,0

Nickel plated brass

II 2G Ex d / II 2D Ex t

0588925

46xx

1/2 NPT

7,5 … 11,9

Nickel plated brass

II 2G Ex d / II 2D Ex t

0589385

46xx, 48xx

M20 x 1,5

9,0 … 13,0

Stainless steel 1.4571

II 2G Ex e / II 2D Ex t

0589395

46xx, 48xx

M20 x 1,5

7,0 … 12,0

Stainless steel 1.4404

II 2G Ex d / II 2D Ex t

0589387

46xx, 48xx

M20 x 1,5

10,0 … 14,0

Stainless steel 1.4404

II 2G Ex d / II 2D Ex t

-

*4) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.

For solenoid

420x/425x

Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *5)

0589737

T5 & Dust Ex: -35°C … + 80°C

T5 & Dust Ex: -40°C … +68°C

T6: -35°C … +70°C

T6: -40°C … +68°C

*5) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.

Connector DIN EN 175301-803

Silencer (plastic) *6)

Silencer (stainless steel) *6)

Exhaust guard *7)

Add-on manual override

Add-on manual override (for start-up only)

0570275, Form A

M/S2 (G1/4)

0014613 (G1/4)

0613422 (1/4")

0553886 (without detent)

0613379 (without detent)

0613423 (1/2")

0553887 (with detent, return at pressure failure)

0663303, Form A (with rectifier)

C/S2 (1/4 NPT)

0613678 (1/4 NPT)

M/S4 (G1/2)

0014813 (G1/2)

C/S4 (1/2 NPT)

0613679 (1/2 NPT)

*6) For indoors use only. *7) For outdoors use ~ 0,2 (bar). *8) Use function descrption 75036430.

0614084 (with detent) *8)


97300 NAMUR Manual override with detent • 3/2- & 5/2-Spool valves electromagnetic actuated, indirectly controlled • G1/4, 1/4 NPT, flanged with NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

VALVES

Technical features Medium: Filtered, lubricated or non-lubricated and dry compressed air Operating pressure: 2 … 8 bar (29 … 116 psi) (below -10°C >must be > 2,5 bar (36psi)) Fluid/Ambient temperature: -15°C … +50°C (-5°F … +122°F) Depending on solenoid system.

Materials: Housing: Aluminium anodized Pilot flange: Pilot flange: Plastic (PBT) Flange plate: Aluminium Seals: NBR

Approval depends on magnetic system

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

4 Technical data Symbol

4

2

4 4

V-52-EM-F

513

2 2

44

2 2

V-32spec-EM-EM V-32spec-EMH-F

5 13 5 13 4 4

2

V-32spec-EM-F

5 13

4 4

2 2

V-32spec-EMH-EMH V-32spec-EMR-F

5 13 5 13

Model *1)

Port size

Actuation/Return

Operating pressure (bar) *2)

Flow (l/min)

9730000

G1/4 NAMUR

Solenoid/Spring

2…8

1230

9730010

1/4 NPT NAMUR

Solenoid/Spring

2…8

1230

9731000

G1/4 NAMUR

Solenoid/Solenoid

2…8

1250

Solenoid/Solenoid

2…8

1250

V-52B-EM V-52-EMH-F

513

2 2

1

V-52B-EMH V-52-EMH-F 9731010 1/4 NPT NAMUR

55 11 33

*1) When ordering please indicate solenoid, voltage and current type (frequency). 4 2 *2) Below -10°C must4be > 2,52bar.

V-32spec-EMR-EMR

V-52B-EMR

29

Solenoids

513

5 13 Model

Rated current

IP-Protection

Ex-Protection (ATEX-Category)

Temperature Ambient/Medium (°C)

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

3050

1,8

4,3

70

IP65 (Connector DIN EN 175301-803, Form B) *3)

-15 … +50

3036

1,6

3,5

30

IP65 (Connector DIN EN 175301-803, Form B) *3)

-15 … +50

3062

2,7

115

IP65 (with 3 m cable) II 2G Ex mb IIC T5 Gb II 2D Ex mb tb IIIC T95°C Db

-20 … +50

3063

2,1

9

IP65 (with 3 m cable) II 2G Ex mb IIC T5 Gb II 2D Ex mb tb IIIC T95°C Db

-20 … +50

Ex e mb IIC T4 Gb Ex tb IIIC T120°C Db I IP 65 (with cable gland) Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. *3) Connector is not scope of delivery, see table »Accessories«.

Approval Model

Approval ATEX

306x

PTB 03 ATEX 2015

Accessories Connector DIN EN 175301-803

Silencer (plastic) *4)

Exhaust guard *5)

0570275, Form A

C/S2 1/4 NPT

0613422 (1/4")

0680003, Form B

M/S2 G1/4

*4) For indoors use only. *5) For outdoors use ~ 0,2 (bar).

For further information www.imi-precision.com

Power consumption


1

26360 & 80207 Inline

VALVES

• 3/2- & 5/2-Spool valves electromagnetic actuated, indirectly controlled

Manual override with and without detent

Technical features

• G1/4, G1/2 The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Medium: Filtered, lubricated or non-lubricated Air Operating pressure: 1 … 10 bar (14 … 145 psi); G1/4 1,5 … 10 bar (21 … 145 psi); G1/2 2 … 10 bar (29 … 145 psi); G1/2 Fluid/Ambient temperature: -10°C … +60°C (+14°F … +140°F) -20°C (-4°F) on request Depending on solenoid system.

Materials: ​Housing: aluminium anodized Pilot flange: plastic (POM) Seals: NBR

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Approval depends on magnetic system

2

30

Technical data 3/2-Way

V-32C-EM-S 1

3 2

Symbol

Model V-32C-EMH-S

1 2

For further information www.imi-precision.com

1

3 4

Port size

Operating pressure (bar)

Flow (l/min)

Manual override with detent

8020765

G1/4

1 … 10

1200

with

V-32C-EMH-S 8020865

G1/2

1,5 … 10

3000

with

Port size

Operating pressure (bar)

Flow (l/min)

Manual override with detent

G1/4

1 … 10

1200

with

2637065

G1/2

2 … 10

3000

with

2636265

G1/4

1 … 10

1200

with

G1/2

2 … 10

3000

with

*1)

3

2

*1) When ordering, please indicate solenoid, voltage and current (frequency).

V-52-EM-S

513

5/2-Way

4 4

2 2

V-52B-EM V-52-EMH-S Model

Symbol

5 51 13 3

*1)

4 4

2636065

2 2

V-52B-EMH V-52-EMH-S 5 51 13 3 4

2

513

V-52B-EMR 2637265

*1) When ordering, please indicate solenoid, voltage and current (frequency).


26360 & 80207 NAMUR Manual override with and without detent

Technical features

• G1/4, NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Medium: Filtered, lubricated or non-lubricated Air Operating pressure: 1 … 10 bar (14 … 145 psi) Fluid/Ambient temperature: -10°C … +60°C (+14°F … +140°F) Depending on solenoid system

Materials: Housing: aluminium anodized Pilot flange: plastic (POM) Seals: NBR

VALVES

• 3/2- & 5/2-Spool valves electromagnetic actuated, indirectly controlled

1

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Approval depends on magnetic system

2

V-AE-32C-EM-F 1 3 2

3

Symbol

31

Technical data 3/2-Way

3

Model *1) V-AE-32C-EMH-F

Port size

Operating pressure (bar)

Flow (l/min)

Manual override with detent

G1/4 NAMUR

1 … 10

1200

with

1 3 2

3

8020747

*1) When ordering, please indicate solenoid, voltage and current (frequency).

4

2

V-52-EM-S

5/2-Way Symbol

513 4 4

2 2

513 513 44

22

513 513 4

2

Model

Port size

Operating pressure (bar)

Flow (l/min)

Manual override with detent

2636047

G1/4 NAMUR

1 … 10

1200

with

G1/4 NAMUR

1 … 10

1200

with

V-52-EMH-S *1) V-52B-EM

V-52-EMH-S V-52B-EMH 2636247

V-52B-EMR 513 *1) When ordering, please indicate solenoid, voltage and current (frequency).

For further information www.imi-precision.com

V-AE-32C-EMR-F 1 3


1

26360 & 80207 NAMUR & Inline Solenoids and accessories

VALVES

Solenoids Model

Power consumption

Rated current

IP-Protection

Ex-Protection (ATEX-Category)

Temperature Ambient/ Medium (°C)

Electrical connection

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

0242

2,7

113

-25 … +60 Fluid: max. 80

Connector DIN EN 175301-803 Form A *2)

0245

4,2

IP65 (with Connector)

-25 … +60 Fluid: max. 80

Connector DIN EN 175301-803 Form A *2)

4210

3,9

162

IP66 (with cable gland)

II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

4211

5,3

23

IP66 (with cable gland)

II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

4610

3,9

162

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

1/2 NPT *2)

4611

5,3

23

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

1/2 NPT *2)

4612

3,9

162

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

4613

5,3

23

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *2) Connector cable gland not supplied see table, "Accessories". Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Approvals 32

Model

Approvals ATEX

IECEx FM

42xx

KEMA 98 ATEX 4452 X

IECEx KEM 09.0068X

46xx

PTB 02 ATEX 2085 X

IECEx PTB 11.0094X

For further information www.imi-precision.com

Accessories Cable gland Protection Ex e, Ex d (ATEX)

Model

For solenoid

Thread

Cable Ø (mm)

Material

Protection class (ATEX)

Ambient temperature limitation

0589735

42xx

M20 x 1,5

7,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *3)

0589736

42xx

M20 x 1,5

10,0 … 14,0

Plastic

II 2G Ex e / II 2D Ex t

See table *3)

0589737

42xx

M20 x 1,5

6,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *3)

0588819

46xx

M20 x 1,5

5,0 … 8,0

Nickel plated brass

II 2G Ex e / II 2D Ex t

0588851

46xx

M20 x 1,5

10,0 … 14,0

Nickel plated brass

II 2G Ex d / II 2D Ex t

0588925

46xx

1/2 NPT

7,5 … 11,9

Nickel plated brass

II 2G Ex d / II 2D Ex t

*3) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.

For solenoid

421x/426x

Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *4)

0589737

T4 & Dust Ex: -35°C … + 80°C

T4 & Dust Ex: -40°C … + 65°C

T6: -35°C … + 55°C

T6: -40°C … + 55°C

*4) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.

Connector DIN EN 175301-803

0570275, Form A *5) For indoors use only. *6) For outdoors use ~ 0,2 (bar).

Silencer (plastic) *5)

Silencer (stainless steel) *5)

Exhaust guard *6)

M/S2 (G1/4)

0014613 (G1/4)

0613422 (1/4")

M/S4 (G1/2)

0613678 (1/4 NPT)

0613423 (1/2")


98025 NAMUR & Inline • G1/4, 1/4 NPT, G1/2, 1/2 NPT & NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Technical features Medium: non-lubricated and dried compressed air, instrument air, nitrogen and other nonflammable neutral, dry fluids Operating pressure: 2 … 8 bar (29 … 116 psi) 0 … 8 bar (0 … 116 psi) with external air supply Fluid/Ambient temperature: -40°C … +60°C (-40°F … +140°F) SIL-Version: -25°C … +60°C (-13°F … +140°F) Depending on solenoid system.

VALVES

• 3/2 poppet valves electromagnetic actuated, indirectly controlled

1

Suited for outdoor use under critical environment conditions Materials: Housing: Aluminium 3.0615 Seal: NBR Inner parts: stainless steel

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Approved

SIL2 @ HFT=0 SIL3 @ HFT=1

Approval depends on magnetic system

Technical data Symbol 2 3

3

Port size 1, 3

2 (3)

Flow (l/min) *2) 1 » 2 2»3

Flow (l/min) *3) 1 » 2 2»3

Material

Test certificate IEC 61508

9802505

G1/4, G1/2

NAMUR G1/4

1250

1500

2500

3100

Aluminium

x

NAMUR 1/4 NPT

1250

1500

2500

3100

Aluminium

x

G1/2

1300

1200

2700

2600

Aluminium

x

1/2 NPT

1300

1200

2700

2600

Aluminium

x

9802515 1/4 NPT, 1/2 NPT V-AE-32C-EM-F 1 2 3

3

9802555

2

G1/2

V-32C-EM-F

11

3

9802565 1/2 NPT V-AE-32C-EMH-F

1

Solenoids

3

1

*1) When ordering, please indicate solenoid, voltage and current (frequency). *2) Inlet pressure 6 bar, outlet pressure 5 bar. *3) Inlet pressure 8 bar, outlet pressure 0 bar.

V-AE-32C-EMR-F

2 Model

1

3

V-32C-EMR-F Power consumption

Rated current

IP-Protection Ex-Protection (ATEX-Category)

Temperature Ambient/ Medium (°C)

Electrical connection

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

0763

1,9

2,1 *4)

78

11

IP65 (with Connector)

-25 … +60

DIN EN 175 301-803 Form A *5)

4200

0,8

38

IP66 (with cable gland)

II 2G Ex eb mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

M20 x 1,5 *5)

4201

1,3

6

IP66 (with cable gland)

II 2G Ex eb mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

M20 x 1,5 *5)

4600

0,8

33

IP66 (with cable gland)

II 2G Ex d mb IIC T5/T6 Gb II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

1/2 NPT *5)

4601

1,3

6

IP66 (with cable gland)

II 2G Ex d mb IIC T5/T6 Gb II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

1/2 NPT *5)

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *4) Required connector: model 0570275 for V DC; model 0663303 for V AC, to be ordered Solenoid Voltage 200V DC! *5) Connector cable gland not supplied, see table »Accessories«. Attention: The protection class for coil series 46xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Approvals Model

Approvals ATEX IECEx

42xx

KEMA 98 ATEX 4452 X

IECEx KEM 09.0068X

46xx

PTB 02 ATEX 2085 X

IECEx PTB 11.0094X

For further information www.imi-precision.com

2 3 to ISO 3 6358 and ISO 8778, 20°C In order to ensure full flow and proper Flow conducted according 2 function make sure that sufficient pressure supply with feed pipe diameters according to the port size is available. V-32C-EMH-F

33

Model *1)


1

98025 NAMUR & Inline

VALVES

Accessories Cable gland Protection Ex e, Ex d (ATEX)

Model

For solenoid

Thread

Cable Ø (mm)

Material

Protection class (ATEX)

Ambient temperature limitation

0589735

42xx

M20 x 1,5

7,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *6)

0589736

42xx

M20 x 1,5

10,0 … 14,0

Plastic

II 2G Ex e / II 2D Ex t

See table *6)

0589737

42xx

M20 x 1,5

6,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *6)

0588819

46xx

M20 x 1,5

5,0 … 8,0

Nickel plated brass

II 2G Ex e / II 2D Ex t

0588851

46xx

M20 x 1,5

10,0 … 14,0

Nickel plated brass

II 2G Ex d / II 2D Ex t

0588925

46xx

1/2 NPT

7,5 … 11,9

Nickel plated brass

II 2G Ex d / II 2D Ex t

*6) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.

For solenoid

420x/425x

Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *7)

0589737

T5 & Dust Ex: -35°C … + 80°C

T5 & Dust Ex: -40°C … +68°C

T6: -35°C … +70°C

T6: -40°C … +68°C

*7) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.

Silencer (plastic) *8)

Exhaust guard *9)

Add-on manual override

Add-on manual override (for start-up only)

0570275, Form A

M/S2 (G1/4)

0613422 (1/4")

0553886 (without detent)

0613379 (without detent)

0613423 (1/2")

0553887 (with detent, return at pressure failure)

34

Connector DIN EN 175301-803

For further information www.imi-precision.com

0663303 Form A (with rectifier)

C/S2 (1/4 NPT) M/S4 (G1/2) C/S4 (1/2 NPT)

*8) For indoors use only. *9) For outdoors use ~ 0,2 (bar). *10) Use function descrption 75036430.

0614084 (with detent) *10)


6215M NAMUR & Inline

Suited for outdoor use under critical environment conditions

Technical features

• Indirect solenoid actuated spool valve

Medium: Filtered, non-lubricated or lubricated and dried compressed air Operating pressure: 2,5 … 8 bar (36 … 116 psi) with internal air supply Orifice: 6 mm (1/4”) Ambient/Media temperature: -40°C … +60°C (-40°F … +140°F)

• 3/2 & 5/2

Material: Body: Aluminum with surface treatment for critical environmental conditions Seals: Special NBR

VALVES

ATEX, IECEx, NEPSI

• G1/4, 1/4 NPT or NAMUR Interface

1

Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below +2°C For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP65 protection must be used!

Technical data

Symbol

1

3

2 4 2 10 12

12 14

1 3 51 3 2 10 4 2 12 1 3 51 3

Port size

Orifice (mm)

Function

Actuation/return

Flow (l/min)

Operating pressure (bar)

Weight (kg)

6215M3530 2

G1/4

6

3/2

Solenoid/spring

1200

2,5 … 8

0,392

6215M3540

1/4 NPT

6

3/2

Solenoid/spring

1200

2,5 … 8

0,392

6

5/2

Solenoid/spring

1200

2,5 … 8

0,442

6

5/2

Solenoid/spring

1200

2,5 … 8

0,442

1

12

3

10 4 2 12

14

1

3

51 3 2 10 G1/4 126215M0530 2 12 4 14

6215M0540 1 3

51 3

1/4 NPT

*1) When ordering please type (frequency). 2 12 4 2indicate 14 12 solenoid, voltage 14 and 4current 51 3

51 3

3/2 and 5/2 way valves NAMUR Housing: Aluminium anodized, Seals: NBR -40°C … +60°C (-40°F … +140°F) 4 2 10 14 52_Namur-EM-F Model *1)

Symbol 5 13 14

44 22 12 10

6215M0500

Ports 1, 3, 5

2, 4

Orifice (mm)

Actuation/return

Flow (l/min)

Operating pressure (bar)

Weight (kg)

G1/4

Flange

6

Solenoid/spring

1200

2,5 … 8

0,48

1/4 NPT

Flange

6

Solenoid/spring

1200

2,5 … 8

0,48

52_Namur-EMH-F 14 14

14

551 13 3 44 22 12 10

6215M0510 52_Namur-EMR-F

551 13 3

*1) When ordering please 4 2indicate 12 solenoid, voltage and current type (frequency). Valve function: 3/2 or 5/2 way function. 14

51 3

For further information www.imi-precision.com

12 14

Model *1)

35

3/2 and 5/2 way valves Inline Housing: anodized, 2 10 2 10Seals: NBR -40°C … +60°C (-40°F … +140°F) 12 Aluminium 12


1

6215M NAMUR & Inline

VALVES

Solenoids group 13B, standard voltages Model

36

Power consumption

Rated current

Protection class

Ex-Protection (ATEX-Category) Temperature Ambient/Media

Electrical connection

Weight

24 V d.c. (W)

230 V a.c. (VA)

24 V d.c. (mA)

230 V a.c. IP/NEMA (mA)

4210

3,9

162

IP66 (with cable gland)

II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db IP66

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

0,5

4211

5,3

23

IP66 (with cable gland)

II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db IP66

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

0,5

4610

3,9

162

IP66 (with cable gland)

II 2 G Ex d mb IIC T4/T6 Gb II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

1/2 NPT *2)

0,8

4611

5,3

23

IP66 (with cable gland)

II 2 G Ex d mb IIC T4/T6 Gb II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

1/2 NPT *2)

0,8

4612

3,9

162

IP66 (with cable gland)

II 2 G Ex d mb IIC T4/T6 Gb II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

0,8

4613

5,3

23

IP66 (with cable gland)

II 2 G Ex d mb IIC T4/T6 Gb II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

0,8

3722

5,5

228

NEMA 4, 4X, 6, 6P, 7, 9

XP/DIP, Div. 1 & 2 CI. I, Gr. A-D CI. II/III, Gr. E-G T3 (160°C)

-20 … +60

Flying leads 450 mm

0,5

3723

5,9

26

NEMA 4, 4X, 6, 6P, 7, 9

XP/DIP, Div. 1 & 2 CI. I, Gr. A-D CI. II/III, Gr. E-G T3 (160°C)

-20 … +60

Flying leads 450 mm

0,5

(°C)

(kg)

For further information www.imi-precision.com

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *2) Connector/cable gland is not scope of delivery, see table »Accessories«. Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Accessories Electrical connection Cable gland Protection class Ex e, Ex d

Model

Approvals Thread

Cable Ø (mm)

Materials

Protection class (ATEX)

Model

42xx

KEMA 98 ATEX 4452 X

IECEx KEM 09.0068X –

46xx

PTB 02 ATEX 2085 X

IECEx PTB 11.0094X

588819

M20 x 1,5

5…8

Nickel plated brass

II 2 GD Ex e

588851

M20 x 1,5

10 … 14

Nickel plated brass

II 2 GD Ex d

588925

1/2 NPT

7,5 … 11,9 Nickel plated brass

II 2 GD Ex d

589385

M20 x 1,5

9 … 13

Stainless steel 1.4571 (316 Ti)

II 2 GD Ex e

589395

M20 x 1,5

7 … 12

Stainless steel 1.4404 (316 L)

II 2 GD Ex d

589387

M20 x 1,5

10 … 14

Stainless steel 1.4404 (316 L)

II 2 GD Ex d

Approvals ATEX

372x, 382x –

IECEx

FM

CSA-LR 57643-6 –

Valve Adaptor complete (Adaptor, inlet filter and seal ring)

Inlet filter

Silencer (plastic) *3)

Silencer (stainless steel) *3)

Silencer (brass) *3)

Exhaust guard *4)

Conversion plate

0613487 (G1/4)

0681173 (G1/4, 1/4 NPT)

M/S2 (G1/4)

0014613 (G 1/4)

T40C2800 (G 1/4)

0613422 (G1/4, 1/4 NPT)

A1502-Z11

C/S2 (1/4 NPT)

0613678 (1/4 NPT)

MS002A (1/4 NPT)

*3) For indoors use only. *4) For outdoors use, opening pressure ~ 0,2 bar.


6215L NAMUR & Inline Technical features

• Indirect solenoid actuated spool valve

Medium: Filtered, non-lubricated and dried compressed air Operating pressure: 2,5 … 8 bar (36 … 116 psi) with internal air supply Ambient/Media temperature: -40°C … +60°C (-40°F … +140°F)

• 3/2 & 5/2

Suited for outdoor use under critical environment conditions ATEX, IECEx, NEPSI

Material: Body: Aluminum with surface treatment for critical environmental conditions Seals: Special NBR

VALVES

• G1/4, 1/4 NPT or NAMUR Interface

1

Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below +2°C For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP65 protection must be used!

Technical data

Symbol

1

3

2 4 2 10 12

12 14

1 3 51 3 2 10 4 2 12 1 3 51 3

Port size

Function

Actuation/return

Flow (l/min)

Operating pressure (bar)

Weight (kg)

6215L3530 2

G1/4

03/2

Solenoid/spring

1200

2,5 … 8

0,392

6215L3540

1/4 NPT

03/2

Solenoid/spring

1200

2,5 … 8

0,392

5/2

Solenoid/spring

1200

2,5 … 8

0,442

5/2

Solenoid/spring

1200

2,5 … 8

0,442

Actuation/return

Flow (l/min)

Operating pressure (bar)

Weight (kg)

1

12

3

10 4 2 12

14

1

3

51 3 2 10 G1/4 126215L0530 2 12 4 14

6215L0540 1 3

51 3

1/4 NPT

*1) When ordering please type (frequency). 2 12 4 2indicate 14 12 solenoid, voltage 14 and 4current 51 3

51 3

3/2 and 5/2 way valves NAMUR Housing: Aluminium anodized, Seals: NBR -40°C … +60°C (-40°F … +140°F) 4 2 10 14 Symbol

52_Namur-EM-F Model *1)

Ports 1, 3, 5

2, 4

6215L0500

G1/4

Flange

Solenoid/spring

900

2,5 … 8

0,48

1/4 NPT

Flange

Solenoid/spring

900

2,5 … 8

0,48

5 13 14

44 22 12 10

52_Namur-EMH-F 14 14

14

551 13 3 44 22 12 10

6215L0510 52_Namur-EMR-F

551 13 3

*1) When ordering please 4 2indicate 12 solenoid, voltage and current type (frequency). Valve function: 3/2 or 5/2 way function. 14

51 3

For further information www.imi-precision.com

12 14

Model *1)

37

3/2 and 5/2 way valves Inline Housing: anodized, 2 10 2 10Seals: NBR -40°C … +60°C (-40°F … +140°F) 12 Aluminium 12


1

6215L NAMUR & Inline

VALVES

Solenoids group, standard voltages Model

Power consumption

Rated current

Protection class

Ex-Protection (ATEX-Category) Temperature Ambient/Media

Electrical connection

Weight

24 V d.c. (W)

230 V a.c. (VA)

24 V d.c. (mA)

230 V a.c. IP/NEMA (mA)

4200

0,8

33

IP 66

II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

M20 x 1,5 *2)

0,6

4201

1,3

6

IP 65

II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

0,6

4600

0,8

33

IP 66

II2G Ex d mb IIC T5/T6 Gb II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

1/2 NPT *2)

0,8

4602

0,8

33

IP 66

II2G Ex d mb IIC T5/T6 Gb II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

M20 x 1,5 *2)

0,8

4601

1,3

6

IP 66

II2G Ex d mb IIC T5/T6 Gb II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

1/2 NPT *2)

0,8

4603

1,3

6

IP 66

II2G Ex d mb IIC T5/T6 Gb II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db

T5: -40 … +80 T6: -40 … +70 -40 … +80

M20 x 1,5 *2)

0,8

3720

1,4

59

4, 4X, 6, 6P, 7, 9

II2G Ex mb d IIC T4/T6 II2G EX mb e II T4/T6 II 2 D Ex td a21

-20 … +60

Flying leads 450 mm

0,4

(°C)

(kg)

38

For further information www.imi-precision.com

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *2) Connector/cable gland is not scope of delivery, see table »Accessories« Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Accessories Electrical connection Cable gland Protection class Ex e, Ex d

Model

Approvals Thread

Cable Ø (mm)

Materials

Protection class (ATEX)

Model

42xx

KEMA 98 ATEX 4452 X IECEx KEM 09.0068X –

46xx

PTB 02 ATEX 2085 X

588819

M20 x 1,5

5…8

Nickel plated brass

II 2 GD Ex e

588851

M20 x 1,5

10 … 14

Nickel plated brass

II 2 GD Ex d

588925

1/2 NPT

7,5 … 11,9 Nickel plated brass

II 2 GD Ex d

589385

M20 x 1,5

9 … 13

Stainless steel 1.4571 (316 Ti)

II 2 GD Ex e

589395

M20 x 1,5

7 … 12

Stainless steel 1.4404 (316 L)

II 2 GD Ex d

589387

M20 x 1,5

10 … 14

Stainless steel 1.4404 (316 L)

II 2 GD Ex d

Approvals ATEX

372x, 382x –

IECEx

FM

CSA-LR 57643-6

IECEx PTB 11.0094X

Valve Adaptor complete (Adaptor, inlet filter and seal ring)

Inlet filter

Silencer (plastic) *3)

Silencer (stainless steel) *3)

Silencer (brass) *3)

Exhaust guard *4)

Conversion plate

0613487 (G1/4)

0681173 (G1/4, 1/4 NPT)

M/S2 (G1/4)

0014613 (G1/4)

T40C2800 (G1/4)

0613422 (G1/4, 1/4 NPT)

A1502-Z11

C/S2 (1/4 NPT)

0613678 (1/4 NPT)

MS002A (1/4 NPT)

*3) For indoors use only. *4) For outdoors use, opening pressure ~ 0,2 bar.


24011 NAMUR & Inline • G1/4, 1/4 NPT, flanged with NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Technical features Medium: Compressed, air filtered, non-lubricated and dry. Other gase and liquid fluids on request Operating pressure: 0 … 10 bar (0 … 145 psi) Flow: 340l/min Fluid/Ambient temperature: -25°C … +80°C (-13°F … +176°F) (NBR) -10°C … +120°C (+14°F … -248°F) (FKM)

1 VALVES

• 3/2 poppet valves electromagnetic actuated, directly controlled

Suited for outdoor use under critical environment conditions Water: +95°C (+ 203°F) -40°C … +60°C (-40°F … +140°F) (VMQ)Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing: stainless steel 1.4404 (316L), brass 2.0402 (Ms 58), anodized aluminium Seal: FKM, NBR, VMQ Inner parts: stainless steel, brass

SIL2 @ HFT=0 SIL3 @ HFT=1

Approved

Approval depends on magnetic system

Technical data Housing: Brass Symbol

2

Solenoidgroup

Port size

Seal

Manual override

Test certificate IEC 61 508

2401103

A+B

G1/4

NBR

Not possible

X

2401149

A+B

G1/4

NBR

Not possible

X

X

2401138

A+B

1/4 NPT

NBR

Not possible

X

X

2014/68/EU

39

1 3

Model *1)

*1) When ordering, please indicate solenoid, voltage and current (frequency).

Housing: Stainless steel (1.4404)

2

Model *1)

Solenoidgroup

Port size

Seal

Manual override

Test certificate IEC 61 508

2401127

A

G1/4

FKM

Not possible

2401147

A

1/4 NPT

FKM

Not possible

2401196

A+B

G1/4

NBR

Upgradeable

X

1025212 *2)

A+B

G1/4

NBR

Upgradeable

X

X

1025328 *2)

A+B

1/4 NPT

NBR

Upgradeable

X

X

2014/68/EU

1 3 3 2 12

3 1

2

3 2 12

3 11

2

*1) When ordering, please indicate solenoid, voltage and current (frequency). *2) Acc. to VDI/VDE 3845 port 1 in flange for attachment of positioners or to interlinking plate (see data sheet N/en 5.8.300).

Housing: Anodized aluminium Symbol 3 2

Model *1)

Solenoidgroup

Port size

Seal

Manual override

Test certificate IEC 61 508

2401191

A+B

G1/4

NBR

Upgradeable

X

X

1025254

A+B

1/4 NPT

NBR

Upgradeable

X

X

2401109 *2)

A+B

G1/4

NBR

Upgradeable

X

X

2014/68/EU

12

3 1

2

3 2 12

3 11

2

*1) When ordering, please indicate solenoid, voltage and current (frequency). *2) Acc. to VDI/VDE 3845 port 1 in flange for attachment of positioners or to interlinking plate (see data sheet N/en 5.8.300).

For further information www.imi-precision.com

Symbol


1

24011 NAMUR & Inline

VALVES

Solenoid operator, solenoid group A Model

Power consumption

Rated current

40

For further information www.imi-precision.com

IP-Protection/ Ex-Protection NEMA (ATEX-Category)

Temperature Ambient/ Medium (°C)

Electrical connection

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

0800

16,9

703

IP65 (with Connector)

-25 … +60 Fluid: max. +80

Connector DIN EN 175301-803 Form A *3)

3803

19,5

75

IP65 (with Connector)

-25 … +60 Fluid: max. +80

Connector DIN EN 175301-803 Form A *3)

4270

8,9

369

IP66 (with cable gland)

II 2G Ex eb mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +65 T5: -40 … +55 -40 … +65

M20 x 1,5 *3)

4271

10,0

43

IP66 (with cable gland)

II 2G Ex eb mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +65 T5: -40 … +55 -40 … +65

M20 x 1,5 *3)

4670

8,9

369

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 T6: -40 … +40 -40 … +70

1/2 NPT *3)

4671

10,0

43

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 T6: -40 … +40 -40 … +70

1/2 NPT *3)

4672

8,9

369

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 T6: -40 … +40 -40 … +70

M20 x 1,5 *3)

4673

10,0

43

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 T6: -40 … +40 -40 … +70

M20 x 1,5 *3)

4872

8,9

369

IP66 (with cable gland)

II 2G Ex mb d IIC T4/T6 Gb II 2G Ex mb e IIC T4/T6 Gb

T4: -40 … +50 T6: -40 … +40

M20 x 1,5 *3)

4873

10

43

IP66 (with cable gland)

II 2G Ex mb d IIC T4/T6 Gb II 2G Ex mb e IIC T4/T6 Gb

T4: -40 … +50 T6: -40 … +40

M20 x 1,5 *3)

3826

13,6

567

4x

Cl. I, Div. 1, Gr. A - D Cl. II/III, Div. 1, Gr. E - G T3C (160°C)

-20 … +60

Flying leads length 460 mm

3827

15,7

68

4x

Cl. I, Div. 1, Gr. A - D Cl. II/III, Div. 1, Gr. E - G T3C (160°C)

-20 … +60

Flying leads length 460 mm

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *3) Connector cable gland not supplied, see table »Accessories« Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Approvals Model

Approvals ATEX IECEx FM

382x

CSA-LR 57643-6

42xx

KEMA 98 ATEX 4452 X

IECEx KEM 09.0068X

46xx

PTB 02 ATEX 2085 X

IECEx PTB 11.0094X

48xx

PTB 06 ATEX 2054 X

IECEx PTB 07.0039X


24011 NAMUR & Inline

1

Model

Power consumption

Rated current

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

0827

6,8

284

3805

10,6

4260

3,9

4261

Electrical connection

IP65 (with Connector)

-25 … +60

Connector DIN EN 175301-803 Form A *3)

46

IP65 (with Connector)

-25 … +60

Connector DIN EN 175301-803 Form A *3)

162

IP66 (with cable gland)

II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *3)

5,3

23

IP66 (with cable gland)

II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *3)

4660

3,9

162

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

1/2 NPT *3)

4661

5,3

23

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

1/2 NPT *3)

4662

3,9

162

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *3)

4663

5,3

23

IP66 (with cable gland)

II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *3)

3824

8,9

369

4x

Cl. I, Div. 1, Gr. A - D Cl. II/III, Div. 1, Gr. E - G T3C (160°C)

-20 … +60

Flying leads length 460 mm

3825

9,5

41

4x

Cl. I, Div. 1, Gr. A - D Cl. II/III, Div. 1, Gr. E - G T3C (160°C)

-20 … +60

Flying leads length 460 mm

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *3) Connector cable gland not supplied, see table »Accessories« Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Approvals Model

Approvals ATEX IECEx FM

382x

CSA-LR 57643-6

42xx

KEMA 98 ATEX 4452 X

IECEx KEM 09.0068X

46xx

PTB 02 ATEX 2085 X

IECEx PTB 11.0094X

For further information www.imi-precision.com

Temperature Ambient/ Medium (°C)

41

IP-Protection/ Ex-Protection NEMA (ATEX-Category)

VALVES

Solenoid operator, solenoid group B


1

24011 NAMUR & Inline

VALVES

Accessories Cable gland Protection Ex e, Ex d (ATEX)

Model

For solenoid

Thread

Cable Ø (mm)

Material

Protection class (ATEX)

Ambient temperature limitation

0589735

42xx

M20 x 1,5

7,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *4)

0589736

42xx

M20 x 1,5

10,0 … 14,0

Plastic

II 2G Ex e / II 2D Ex t

See table *4)

0589737

42xx

M20 x 1,5

6,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *4)

0588819

46xx

M20 x 1,5

5,0 … 8,0

Nickel plated brass

II 2G Ex e / II 2D Ex t

0588851

46xx

M20 x 1,5

10,0 … 14,0

Nickel plated brass

II 2G Ex d / II 2D Ex t

0588925

46xx

1/2 NPT

7,5 … 11,9

Nickel plated brass

II 2G Ex d / II 2D Ex t

0589385

46xx, 48xx

M20 x 1,5

9,0 … 13,0

Stainless steel 1.4571

II 2G Ex e / II 2D Ex t

0589395

46xx, 48xx

M20 x 1,5

7,0 … 12,0

Stainless steel 1.4404

II 2G Ex d / II 2D Ex t

0589387

46xx, 48xx

M20 x 1,5

10,0 … 14,0

Stainless steel 1.4404

II 2G Ex d / II 2D Ex t

*4) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.

For solenoid

421x/426x 422x/427x

Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *5)

0589737

T4 & Dust Ex: -35°C … + 80°C

T4 & Dust Ex: -40°C … + 65°C

T6: -35°C … + 55°C

T6: -40°C … + 55°C

T4 & Dust Ex: -35°C … +65°C

T4 & Dust Ex: -40°C … + 62°C

T5: -35°C … + 55°C

T5: -40°C … + 55°C

*5) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.

42 Connector DIN EN 175301-803

For further information www.imi-precision.com

0570275, Form A *6) For indoors use only *7) For outdoors, use ~ 0,2 (bar)

Silencer (plastic) *6)

Silencer (stainless steel) *6)

Exhaust guard *7)

Add-on manual override

Add-on manual override

C/S2 1/4 NPT

0014613 (G1/4)

0613422 (1/4")

0601765 (with detent)

0600205 (without detent)

M/S2 G1/4

0613678 (1/4 NPT)


24010 NAMUR & Inline • G1/4, 1/4 NPT, flanged with NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Solenoid valves with low Power consumption

Technical features Medium: Compressed air, filtered, non-lubricated and dry. Other fluids on request. Operating pressure: 0 … 10 bar (0 … 145 psi) Flow: 340 I/min Fluid/Ambient temperature: -25°C … +60°C (-13°F … +140°F) Depending on solenoid system

VALVES

• 3/2 poppet valves electromagnetic actuated, directly controlled

1

High operational reliability even after long periods of non-operation

For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing: brass 2.0402 (Ms 58), stainless steel 1.4404 (316L), hard anodized aluminium 3.0615 Seal: Stainless steel, Brass Solenoid housing: Aluminium 3.0615, hard anodised Seals: NBR

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

SIL2 @ HFT=0 SIL3 @ HFT=1

DIN EN 61508 IEC 61508 Approval depends on magnetic system

Technical data Symbol

Model

Port size

Operating pressure (bar)

Manual Override

Seal:

2401088200300000

G1/4

0 … 10

Not Possible

NBR

Brass

2401087200300000

1/4 NPT

0 … 10

Not Possible

NBR

Brass

2401086200300000

G1/4

0 … 10

Not Possible

NBR

Stainless steel

1 3

2401012200300000

1/4 NPT

0 … 10

Not Possible

NBR

Stainless steel

3 2

2401091200300000

G1/4 NAMUR

0 … 10

Upgradeable

NBR

Aluminium

2401090200300000

1/4 NPT NAMUR

0 … 10

Upgradeable

NBR

Aluminium

2

Housing

12

3 1

2

Solenoid parameters for use in non harardous locations Switch-on voltage

Current consumption

Power consumption

Pick-up delay typical *1)

(V)

(mA)

(W)

(s)

2003

22 … 26,4

< 75

1,8 at 24 V

0,3 … 2

Ex-Protection (ATEX-Category)

Temperature Ambient/Fluid

Weight

(°C)

(kg)

IP66 with cable gland (cable Ø 5 … 10 mm) is in scope of delivery

-40 … +80

0,85

IP-Protection

Ex-Protection (ATEX-Category)

Temperature Ambient/Fluid

Weight

(°C)

(kg)

IP66 with cable gland (cable Ø 5 … 10 mm) is in scope of delivery

II 2G Ex ia IIC T5/T6 II 2D Ex tD IP66 T95°C

T5: -40 … +70 T6: -40 … +55 -40 … +70

0,85

*1) depending on intrinsical current supply.

Solenoid parameters for use in intrinsically safe circuits Symbol

Model

Switch-on voltage (V)

2003

22 … 28

Holding current

Holding voltage

(mA)

(V)

> 40

~5

Pick-up delay typical *1) (s) 0,3 … 5

*1) depending on intrinsical current supply.

Operating sequence

Approvals

U (V)

Model

Approvals ATEX IECEx

28

2003

PTB 04 ATEX 2010

22

IECEx PTB 05.0020

1

Accessories Silencer (plastic) *2)

Silencer (stainless steel) *2)

2

Exhaust guard *3) 0

t I (mA)

75 60 40 20 0

M/S2 (G1/4)

0014613 (G1/4)

C/S2 (1/4 NPT)

0613678 (1/4 NPT)

0613422 (1/4")

3 t 1 Supply voltage 2 Capacitor charging voltage

ON

*2) For indoors use only. *3) For outdoors use ~ 0,2 (bar).

3 Solenoid current

4 OF

t

4 Valve status

For further information www.imi-precision.com

Standard voltages (±10%), Design according to VDE 0580, EN 50014/50028. 100% duty cycle. Pick-up delay typical: 0,3 … 2 s, depending on intrinsical current supply.

IP-Protection

43

Model


1

98015 NAMUR & Inline

VALVES

• 3/2- & 5/2-Spool valves electromagnetic actuated, indirectly controlled

Suited for outdoor use under critical environment conditions

Technical features Medium: Filtered, non-lubricated and dried compressed Air Operating pressure: 0 … 10 bar (0 … 145 psi) Flow: see Tabelle Fluid/Ambient temperature: -40°C … +60°C (-40°F … +140°F) (NBR) -25°C … +60°C (-13°F … +140°F) (SIL version) Depending on solenoid system

• G1/4, G1/2

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing: stainless steel 1.4404 (316L), brass, aluminium anodized Seal: NBR Inner parts: stainless steel or brass Approved

SIL2 @ HFT=0 SIL3 @ HFT=1

Approval depends on magnetic system

Technical data Symbol

2

1

3

3 2

44

1

3

Model *1)

Port size 1, 3

2 (3)

Flow (l/min) *2) 1 » 2 2 » 3

Flow (l/min) *3) 1 » 2 2 » 3

Operating pressure (bar)

Material

Manual overrideSolenoids

Test certificate IEC 61 508

9801505

G1/4, G1/2

NAMUR, G1/4

1100

1300

2900

3400

0 … 10

Aluminium

Upgradeable

x

9801515 1/4 NPT, 1/2 NPT NAMUR, 1/4 NPT 1100 V-AE-32C-E-S

1300

2900

3400

0 … 10

Aluminium

Upgradeable

x

9801755

G1/2

1200

1300

3100

3400

0 … 10

Stainless steel

Upgradeable

x

9801765 1/2 NPT V-32C-all-E-F 9801655 G1/2

G1/2

1/2-NPT

1200

1300

3100

3400

0 … 10

Stainless steel

Upgradeable

x

G1/2

1200

1300

3100

3400

0 … 10

Brass

Upgradeable

x

9801665

1/2-NPT

1200

1300

3100

3400

0 … 10

Brass

Upgradeable

x

1/2 NPT

*1) When ordering 2please indicate solenoid, voltage and current type (frequency). *2) Inlet pressure 6 bar, outlet pressure 5 bar.

*3) Inlet pressure 10 bar, Outlet pressure 0 Bar.

V-32C-all-EH-F

Solenoids1

3

For further information www.imi-precision.com

2 1

3

Model Power Rated current IPV-32C-all-ER-F consumption Protection 24 V DC 230 V AC 24 V DC 230 V AC (W) (VA) (mA) (mA)

Ex-Protection (ATEX-Category)

Ambient Temperature Medium (°C)

Electrical connection

0800

16,9

703

IP65 (with Connector)

-25 … +60 Fluid: max. 80

Connector DIN EN 175301-803 Form A *4)

3803

17,3

75

IP65 (with Connector)

-25 … +60 Fluid: max. 80

Connector DIN EN 175301-803 Form A *4)

4270

8,9

369

IP66 (with II 2G Ex eb mb IIC T4/T5 Gb T4: -40 … +65 M20 x 1,5 *4) cable gland) II 2D Ex tb IIIC T130°C Db T5: -40 … +55 -40 … +65

4271

10,0

43

IP66 (with II 2G Ex eb mb IIC T4/T5 Gb T4: -40 … +65 M20 x 1,5 *4) cable gland) II 2D Ex tb IIIC T130°C Db T5: -40 … +55 -40 … +65

4670

8,9

369

IP66 (with II 2G Ex d mb IIC T4/T6 Gb cable gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 1/2 NPT *4) T6: -40 … +40 -40 … +70

4671

10,0

43

IP66 (with II 2G Ex d mb IIC T4/T6 Gb cable gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 1/2 NPT *4) T6: -40 … +40 -40 … +70

4672

8,9

369

IP66 (with II 2G Ex d mb IIC T4/T6 Gb cable gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 M20 x 1,5 *4) T6: -40 … +40 -40 … +70

4673

10,0

43

IP66 (with II 2G Ex d mb IIC T4/T6 Gb cable gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 M20 x 1,5 *4) T6: -40 … +40 -40 … +70

4872

8,9

369

IP66 (with II 2G Ex mb d IIC T4/T6 Gb T4: -40 … +50 M20 x 1,5 *4) cable gland) II 2G Ex mb e IIC T4/T6 Gb T6: -40 … +40

42xx

KEMA 98 IECEx KEM ATEX 4452 X 09.0068X

IP66 (with II 2G Ex mb d IIC T4/T6 Gb T4: -40 … +50 M20 x 1,5 *4) cable gland) II 2G Ex mb e IIC T4/T6 Gb T6: -40 … +40

46xx

IECEx PTB PTB 02 ATEX 2085 X 11.0094X

4873

10,0

43

Approvals Model Approvals ATEX IECEx

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED. *4) Connectors/Cable gland is not included, see accessories. Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.


98015 NAMUR & Inline

1

Cable gland Protection Ex e, Ex d (ATEX)

Model

For solenoid

Thread

Cable Ø (mm)

Material

Protection class (ATEX)

Ambient temperature limitation

0589735

42xx

M20 x 1,5

7,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *5)

0589736

42xx

M20 x 1,5

10,0 … 14,0

Plastic

II 2G Ex e / II 2D Ex t

See table *5)

0589737

42xx

M20 x 1,5

6,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *5)

0588819

46xx

M20 x 1,5

5,0 … 8,0

Nickel plated brass

II 2G Ex e / II 2D Ex t

0588851

46xx

M20 x 1,5

10,0 … 14,0

Nickel plated brass

II 2G Ex d / II 2D Ex t

0588925

46xx

1/2 NPT

7,5 … 11,9

Nickel plated brass

II 2G Ex d / II 2D Ex t

0589385

46xx, 48xx

M20 x 1,5

9,0 … 13,0

Stainless steel 1.4571

II 2G Ex e / II 2D Ex t

0589395

46xx, 48xx

M20 x 1,5

7,0 … 12,0

Stainless steel 1.4404

II 2G Ex d / II 2D Ex t

0589387

46xx, 48xx

M20 x 1,5

10,0 … 14,0

Stainless steel 1.4404

II 2G Ex d / II 2D Ex t

VALVES

Accessories

*5) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.

For solenoid

422x/427x

Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *6)

0589737

T4 & Dust Ex: -35°C … +65°C

T4 & Dust Ex: -40°C … +62°C

T5: -35°C … +55°C

T5: -40°C … +55°C

*6) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.

Silencer (stainless steel) *7)

Exhaust guard *8)

Add-on manual override

Add-on manual override

0570275, Form A

C/S2 (1/4 NPT)

0014613 (G1/4)

0613422 (1/4")

0601765 (with detent)

0600205 (without detent)

M/S2 (G1/4)

0613678 (1/4 NPT)

0613423 (1/2")

C/S4 (1/2 NPT)

0014813 (G1/2)

M/S4 (G1/2)

0613679 (1/2 NPT)

*7) For indoors use only. *8) For outdoors, use ~ 0,2 (bar).

For further information www.imi-precision.com

Silencer (plastic) *7)

45

Connector DIN EN 175301-803


1

21000

Seals in either flow direction

VALVES

• 2/2-poppet valves electromagnetic actuated, directly controlled

Technical features

• G1/2 The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Medium: For neutral, gaseous and liquid fluids Operating pressure: 0 … 15 bar (0 … 217 psi) 0 … 50 bar (0 … 725 psi) Fluid temperature: -25°C … +80°C NBR Ambient temperature: -25°C … +80°C (-13°F … +176°F) -25°C … +60°C (-13°F … +140°F) Depending on solenoid system

Materials: Housing: Brass Seat seal: NBR Inner parts: Brass,Stainless steel 1.4104 (430 F)

Approval depends on magnetic system

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

46

Technical data Valves in protection class IP65 and Ex em Symbol

For further information www.imi-precision.com

2 10

12

Model *1)

Solenoids group

Port size

Orifice

Operating pressure (bar)

Flow (l/min)

2102250

30,5 A

G1/2

12

0 … 15

1100

2101850

38,5 A

G1/2

12

0 … 50

1100

1 2 10 2 10

12 12 1 1

2 12 please indicate 10solenoid, voltage and current (frequency). Valve function: APB = All Ports Blocked Approval depends on magnetic system. *1) When ordering, 2 10 12 1 1 2 10

12 1


23200

Seals in either flow direction

• G1/2, G1 The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Technical features Medium: Neutral gases and liquids, aggressive gases and liquids (with contaminated fluids upstream installation of a dirt trapis recommended) Operating pressure: 0 … 6 bar (0 … 87 psi) 0 … 10 bar (0 … 145 psi) Fluid/Ambient temperature: Depending on solenoid system -25°C … +80°C (-13°F … +176°F), Brass -10°C … +80°C (14°F … +176°F), Grey cast iron

VALVES

• 2/2-poppet valves electromagnetic actuated, directly controlled

Materials: Housing: brass 2.0401 or Grey cast iron Seat seal:NBR or FKM Inner parts: Brass 2.0401 (Ms 58), Stainless steel 1.4104 (430 F) Stainless steel 1.4104 (430 F)

Approval depends on magnetic system

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

47

Technical data Symbol

Model *1)

Port size

Solenoid-group

Orifice (mm)

Operating pressure (bar)

Flow (l/min)

Material Housing

2323120

G1/2

30,5A

12

0 … 10

1525

Brass

NBR

2322520 V-22C-all-E-FG 1

38,5A

25

0…6

9925

Grey cast iron

NBR

2323620

47,5A

25

0 … 10

9925

Grey cast iron

NBR

Seat seal

G1

2

*1) When ordering please indicate solenoid, voltage and current type (frequency).

V-22C-all-EH-F

1 2

V-22C-all-ER-F 1

For further information www.imi-precision.com

2 1

1


1

24000

VALVES

• 3/2 poppet valves electromagnetic actuated, directly controlled • G1/4, G1/2 The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Suited for outdoor use

Technical features Medium: For neutral, gaseous and liquid fluids Operating pressure: 0 … 12 bar (0 … 174 psi) 0 … 15 bar (0 … 217 psi) 0 … 25 bar (0 … 362 psi) 0 … 40 bar (0 … 580 psi) 0 … 100 bar (0 … 1450 psi) Ambient temperature: -25°C … +60°C (-13°F … 140°F) -40°C … +40°C (-40°F … 104°F)

Fluid temperature: -25°C … +80°C (-13°F … +176°F) NBR -40°C … +80°C (-40°F … +176°F) TPE Depending on solenoid system and Seal. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing Seat seal see Fluid temperature Inner part: Brass, Steel Approval depends on magnetic system

48

Technical data Symbol

Model *1)

For further information www.imi-precision.com

2 1

3 2

Port size

Solenoids group

Material Housing

Seat seal

G1/4

30,5A

8

0 … 15

750

Brass

NBR

G1/2

30,5A

12

0 … 12

1380

Brass

NBR

V-32O-all-E-F 2402750 G1/2

38,5A

12

0 … 25

1380

Brass

NBR

2406750

G1/2

38,5A

12

0 … 40

1380

Brass

NBR

2407965

G1/2

38,5A

12

0 … 100

1380

Brass

Stainless steel *2)

3

V-32O-all-ER-F 3

Flow (l/min)

2401550

2 1

Operating pressure (bar)

2402550

*1) When ordering please indicate solenoid, voltage and current type (frequency). V-32O-all-EH-F *2) Suitable for liquids only.

1

Orifice (mm)


21000, 23200 & 24000

1

Solenoids and accessories Model

Power consumption

Rated current

IP-Protection

Ex-Protection (ATEX-Category)

Ambient Temperature/Medium (°C)

Electrical connection

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

1300

21,4

891

IP65 (with cable gland)

-25 … +60

M20 x 1,5

1301

22,8

99

IP65 (with cable gland)

-25 … +60

M20 x1,5

1440

21,4

891

IP65 (with cable gland)

II 2G Ex e mb IIC T4/T5 Gb T4: -20 … +80 II 2D Ex tb IIIC T120°C Db IP65 T5: -40 … +60 -40 … +80

M20 x1,5

1441

22,8

99

IP65 (with cable gland)

II 2G Ex e mb IIC T4/T5 Gb T4: -20 … +80 II 2D Ex tb IIIC T120°C Db IP65 T5: -40 … +60 -40 … +80

M20 x1,5

IP-Protection

Ex-Protection (ATEX-Category)

Ambient Temperature/Medium (°C)

Electrical connection

VALVES

Solenoids Solenoids group 30,5A

Solenoids group 38,5A Model

Rated current

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

1500

38,7

1614

IP65 (with cable gland)

-25 … +60 Fluid max. +80

M20 x 1,5

1501

42,1

169

IP65 (with cable gland)

-25 … +60 Fluid max. +80

M20 x 1,5

1570

38,7

1614

IP65 (with cable gland)

II 2G Ex e mb IIC T4 Gb

-20 … +40

M20 x 1,5 *8)

1571

42,1

169

IP65 (with cable gland)

II 2G Ex e mb IIC T4 Gb

-20 … +40

M20 x 1,5 *8)

49

Power consumption

Model

Approvals ATEX IECEx

143x, 144x

KEMA 03 ATEX 1016 X

IECEx DEK 11.0066X

15xx, 157x

DEKRA BVS 08 ATEX E 117

Solenoids group 47,5A (only for Serie 23200) Model

Power consumption 24 V DC 230 V AC (W) (VA)

Rated current 24 V DC 230 V AC (mA) (mA)

IP-Protection

Ex-Protection (ATEX-Category)

Ambient Temperature/Medium (°C)

Electrical connection

1600

52,3

2181

IP65 (with cable gland)

-40 … +40 Fluid max. +80

M20 x 1,5 *3)

1601

56,4

245

IP65 (with cable gland)

-40 … +40 Fluid max. +80

M20 x 1,5 *3)

Standardvoltages 230 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN50014/50028. Duty cycle 100% ED. *3) Cable gland is not scope of delivery, see table »Accessories«. IP66 version on request.

Accessories Cable gland IP 65 Protection Ms Nickel plated brass

Model

Port size

Cable Ø

0589241

M 20x1,5

6,5 … 9,5 mm

0589242

M 20x1,5

9,0 … 13 mm

Cable gland Ex-Protection Ms Nickel plated brass

Model

Protection

Cable Ø

0588819

II 2GD Ex e

5 … 8 mm

0588851

II 2GD Ex d

10 … 14 mm

0588925

II 2GD Ex d

7,5 … 11,9 mm

For further information www.imi-precision.com

Approvals


1

95000

VALVES

• 2/2-poppet valves electromagnetic actuated, directly controlled • G1/4, 1/4 NPT, G1/2 The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

For a.c. solenoid systems with integrated rectifier (40 … 60 Hz)

Technical features Medium: For neutral gaseous and liquid fluids (with contaminated fluids, upstream installation of a dirt trap is recommended.) Operating pressure: 0 … 1 bar (0 … 14 psi) 0 … 5 bar (0 … 72 psi) 0 … 10 bar (0 … 145 psi) 0 … 12 bar (0 … 174 psi) 0 … 20 bar (0 … 290 psi) 0 … 35 bar (0 … 507 psi) 0 … 40 bar (0 … 580 psi)

Fluid/ Ambient temperature: -25°C … +80°C (-13°F … +176°F) NBR Depending on solenoid system and Seal. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Materials: Housing: Brass 2.0401 Seal: NBR Inner parts: Steel 1.4104 (430 F), Brass 2.0401 (Ms 58)

Approval depends on magnetic system

Technical data 50

Switching function: Normally closed Symbol

Model *1)

For further information www.imi-precision.com

2 1 2 1

Port size

Orifice (mm)

Operating pressure (bar)

Material Seat seal

Flow (l/min)

Solenoid group

9500100

G1/4

1,5

0 … 40

NBR

70

13B

9500200

G1/4

2

0 … 35

NBR

120

13B

9503200

1/4 NPT

2

0 … 35

NBR

120

13B

9500300

G1/4

3

0 … 10

NBR

200

13C

9503300

1/4 NPT

3

0 … 10

NBR

200

13C

9500400

G1/4

4

0 … 12

NBR

350

13D

9503400

1/4 NPT

4

0 … 12

NBR

350

13D

9501600

G1/4

6

0…5

NBR

550

16D

9504600

1/4 NPT

6

0…5

NBR

550

16D

9501700

G1/2

12

0…1

NBR

1700

16D

*1) When ordering please indicate solenoid, voltage and current type (frequency). Technical data and ordering2information see following pages.

1 Switching function: Normally open Symbol

2

Model *1)

Port size

Orifice (mm)

Operating pressure (bar)

Material Seat seal

Flow (l/min)

Solenoid group

9502210

G1/4

2

0 … 20

NBR

100

13B

G1/4

3

0 … 10

NBR

160

13B

V-22O-E-F 9502310

1

*1) When ordering please indicate solenoid, voltage and current type (frequency). 2 Technical data and ordering information see following pages.

V-22O-EH-F

1 2

V-22O-ER-F 1


96000 • G1/4, 1/4 NPT The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).

Technical features Medium: For neutral gaseous and liquid fluids (with contaminated fluids, upstream installation of a dirt trap is recommended.) Operating pressure: 0 … 9 bar (0 … 130 psi) 0 … 10 bar (0 … 145 psi) Fluid/Ambient temperature: -25°C … +80°C (-13°F … +176°F) NBR Depending on solenoid system and Seal.

Materials: Housing: Brass Seal: NBR Inner parts: Steel 1.4104 (430 F) Brass 2.0401 (Ms 58)

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

1 VALVES

• 3/2 poppet valves electromagnetic actuated, directly controlled

For a.c. solenoid systems with integrated rectifier (40 … 60 Hz)

Approval depends on magnetic system

Technical data Symbol

2

Port size

Orifice (mm)

Operating pressure (bar)

Materials: Seat

Flow (l/min)

Solenoid group

9600210

G1/4

2

0 … 10

NBR

120

13B

3

1/4 NPT

2

0 … 10

NBR

120

13B

9603210

*1) When ordering please indicate solenoid, voltage and current type (frequency).

Technical data and ordering information see following pages.

2

V-32C-EH-F 1

3

Switching function: Normally open 2

Symbol

Model *1)

Port size

Orifice (mm)

Operating pressure (bar)

Materials: Seat

Flow (l/min)

Solenoid group

9602210

G1/4

2

0…9

NBR

100

13B

1/4 NPT

2

0…9

NBR

100

13B

V-32C-ER-F 1 3 2

V-32O-E-F 1

3

9605210

2 *1) When ordering please indicate solenoid, voltage and current type (frequency).

V-32O-EH-F 1

3 2

V-32O-ER-F 1

3

Technical data and ordering information see following pages.

For further information www.imi-precision.com

Model *1)

V-32C-E-F 1

51

Switching function: Normally closed


1

95000/96000 Solenoids

VALVES

Solenoid group 13B, Standard voltages Model

Power consumption

Rated current

52

IP-Protection

Ex-Protection (ATEX-Category)

Temperature Ambient/Medium (°C)

Electrical connection

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

0246

8,0

331

IP65 (with Connector)

-25 … +60 Fluid: max. +80

Connector DIN EN 175301-803, Form A *2)

3206

9,2

40

IP65 (with Connector)

-25 … +60 Fluid: max. +80

Connector DIN EN 175301-803, Form A *8)

4210

3,9

162

IP66 (with cable II 2G Ex eb mb IIC T4/T6 Gb gland) II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

4211

5,3

23

IP66 (with cable II 2G Ex eb mb IIC T4/T6 Gb gland) II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

4610

3,9

162

IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

1/2 NPT *2)

4611

5,3

23

IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

1/2 NPT *2)

4612

3,9

162

IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

4613

5,3

23

IP66 (with cable Ex d mb IIC T4/T6 Gb gland) Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db

T4: -40 … +80 T6: -40 … +55 -40 … +80

M20 x 1,5 *2)

For further information www.imi-precision.com

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED. *2) Connectors/Cable gland is not included, see accessories. Attention: The protection class for coil series 46xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

Approvals Model

Approvals ATEX IECEx FM

42xx

KEMA 98 ATEX 4452 X

IECEx KEM 09.0068X

46xx

PTB 02 ATEX 2085 X

IECEx PTB 11.0094X


95000/96000 Solenoids

1

Model

Power consumption

Rated current

Ex-Protection (ATEX-Category)

Temperature Ambient/Medium (°C)

Electrical connection

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

0200

12,1

504

IP65 (with Connector)

-25 … +60 Fluid: max. +80

Connector DIN EN 175301-803, Form A *2)

3204

11,3

49

IP65 (with Connector)

-25 … +60 Fluid: max. +80

Connector DIN EN 175301-803, Form A *2)

4220

8,9

369

IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db

T4: -40 … +65 T5: -40 … +55 -40 … +65

M20 x 1,5 *2)

4221

10,0

43

IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db

T4: -40 … +65 T5: -40 … +55 -40 … +65

M20 x 1,5 *2)

4620

8,9

369

IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 T6: -40 … +40 -40 … +70

1/2 NPT *2)

4621

10,0

43

IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 T6: -40 … +40 -40 … +70

1/2 NPT *2)

4622

8,9

369

IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 T6: -40 … +40 -40 … +70

M20 x 1,5 *2)

4623

10,0

43

IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +70 T6: -40 … +40 -40 … +70

M20 x 1,5 *2)

Approvals Model

Approvals ATEX IECEx FM

42xx

KEMA 98 ATEX 4452 X

IECEx KEM 09.0068X

46xx

PTB 02 ATEX 2085 X

IECEx PTB 11.0094X

For further information www.imi-precision.com

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED. *2) Connectors/Cable gland is not included, see accessories. Attention: The protection class for coil series 46xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

53

IP-Protection

VALVES

Solenoid group 13C, Standard voltages


1

95000/96000 Solenoids

VALVES

Solenoid group 13D, Standard Voltage Model

Power consumption

Rated current

IP-Protection

Ex-Protection (ATEX-Category)

Temperature Ambient/Medium (°C)

Electrical connection

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

0700

16,9

703

IP65 (with Connector)

-25 … +60 Fluid: max. +80

Connector DIN EN 175301-803, Form A *2)

3703

19,5

75

IP65 (with Connector)

-25 … +60 Fluid: max. +80

Connector DIN EN 175301-803, Form A *2)

4230

11,4

475

IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

M20 x 1,5 *2)

4231

15,2

66

IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

M20 x 1,5 *2)

4630

11,4

475

IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

1/2 x NPT *2)

4631

15,2

66

IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

1/2 x NPT *2)

4632

11,4

475

IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

M20 x 1,5 *2)

4633

15,2

66

IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

M20 x 1,5 *2)

54

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED. *2) Connectors/Cable gland is not included, see accessories. Attention: The protection class for coil series 46xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

For further information www.imi-precision.com

Approvals Model

Approvals ATEX IECEx

42xx

KEMA 98 ATEX 4452 X

IECEx KEM 09.0068X

46xx

PTB 02 ATEX 2085 X

IECEx PTB 11.0094X


95000/96000 Solenoids and accessories

1

Model

Power consumption

Rated current

IP-Protection

Ex-Protection (ATEX-Category)

Temperature Ambient/Medium (°C)

Electrical connection

24 V DC 230 V AC (W) (VA)

24 V DC 230 V AC (mA) (mA)

0800

16,9

703

IP65 (with Connector)

-25 … +60 Fluid: max. +80

Connector DIN EN 175301-803 Form A *2)

3803

19,5

75

IP65 (with Connector)

-25 … +60 Fluid: max. +80

Connector DIN EN 175301-803 Form A *2)

4280

11,4

475

IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

M20 x 1,5 *2)

4281

15,2

66

IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

M20 x 1,5 *2)

4680

11,4

475

IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

1/2 x NPT *2)

4681

15,2

66

IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

1/2 x NPT *2)

4682

11,4

475

IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

M20 x 1,5 *2)

4683

15,2

66

IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db

T4: -40 … +50 T5: -40 … +40 -40 … +50

M20 x 1,5 *2)

Approvals Model

Approvals ATEX IECEx KEMA 98 ATEX 4452 X

IECEx KEM 09.0068X

PTB 02 ATEX 2085 X

IECEx PTB 11.0094X

Accessories Cable gland Protection Ex e, Ex d (ATEX)

Model

For solenoid

Thread

Cable Ø (mm)

Material

Protection class (ATEX)

Ambient temperature limitation

0589735

42xx

M20 x 1,5

7,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *3)

0589736

42xx

M20 x 1,5

10,0 … 14,0 Plastic

II 2G Ex e / II 2D Ex t

See table *3)

0589737

42xx

M20 x 1,5

6,0 … 12,0

Plastic

II 2G Ex e / II 2D Ex t

See table *3)

0588819

46xx

M20 x 1,5

5,0 … 8,0

Nickel plated brass

II 2G Ex e / II 2D Ex t

0588851

46xx

M20 x 1,5

10,0 … 14,0 Nickel plated brass

II 2G Ex d / II 2D Ex t

0588925

46xx

1/2 NPT

7,5 … 11,9

II 2G Ex d / II 2D Ex t

Nickel plated brass

*3) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.

For solenoid

421x/426x

422x/427x

423x/428x

Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *4)

0589737

T4 & Dust Ex: -35°C … + 80°C

T4 & Dust Ex: -40°C … + 65°C

T6: -35°C … + 55°C

T6: -40°C … + 55°C

T4 & Dust Ex: -35°C … +65°C

T4 & Dust Ex: -40°C … + 62°C

T5: -35°C … + 55°C

T5: -40°C … + 55°C

T4 & Dust Ex: -35°C … +50°C

T4 & Dust Ex: -40°C … +50°C

T5: -35°C … +40°C

T5: -40°C … +40°C

*4) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.

Connector DIN EN 175301-803

0570275, Form A

For further information www.imi-precision.com

42xx 46xx

55

Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED. *2) Connectors/Cable gland is not included, see accessories. Attention: The protection class for coil series 46xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.

VALVES

Solenoid group 16D, Standard Voltage


1

6316 Inline

VALVES

• 3/2 poppet valves

Technical features

• Electromagnetic actuated, Manual Override (optional)

Medium: Compressed Air Operating pressure: 0 … 8 bar (0 … 116 psi) Orifice: 3 mm Flow direction: Fixed Ambient/Media temperature: Ambient: -20°C … +60°C (-4°F … +140°F) Media: -20°C … +80°C (-4°F … +176°F) Depending on solenoid system

• G1/4, 1/4 NPT • For single acting actuators • Protection class of Coil is up to IP 65 * ATEX Version available from July 2017

Materials: Body: Aluminum (Anodized), Brass and SS 316L for critical environment conditions. Seals: FKM Note: For Outdoor installations Coil must be protected from moisture by using cable gland of IP 65 or above.

Valve switches at power NO, NC, failure into starting Universal valve position (Mechanical return spring)

Suited for outdoor use under IP 65 conditions

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

3/2 Way Universal Valves with temperature -20°C … +80°C, Housing: Aluminum, Brass and SS316L Symbol

2

1 3

56

Model *1)

Port size

Material

Actuation/return

Operating pressure (bar)

Flow (l/min)

Weight (kg)

631605316001***

G1/4

Aluminium

Solenoid/ air spring

0…8

340

0,33

631605416001***

1/4 NPT

Aluminium

Solenoid/ air spring

0…8

340

0,33

631615316001***

G1/4

Brass

Solenoid/ air spring

0…8

340

0,67

631615416001***

1/4 NPT

Brass

Solenoid/ air spring

0…8

340

0,67

631625316001***

G1/4

SS 316L

Solenoid/ air spring

0…8

340

0,65

631625416001***

1/4 NPT

SS 316L

Solenoid/ air spring

0…8

340

0,65

*1) When ordering, please indicate solenoid, voltage and current (frequency).

For further information www.imi-precision.com

Voltage

Substitute

24 V d.c.

02400

110 V a.c.

11050

230 V a.c.

23050

Flow 1 bar differential pressure ~ 160 lpm.

Solenoids, standard voltages Model

Power consumption 24 V d.c. 110 V a.c. (W) (VA) ~-18 –

230 V a.c. (VA) –

Rated current 24 V d.c. 110 V a.c. (A) (A) ~0,7 –

230 V a.c. (A) –

~-18

~0,14

IP 65 (with connector)

~-18

~0,08

IP 65 (with connector)

6316****.6001

6316****.6001

6316****.6001 Standard voltages (±10%) 24 V d.c., 110 V a.c., 230 V a.c., other voltages on request. 100% duty cycle. Note: For Outdoor installations Coil must be protected from moisture by using cable gland of IP 65 or above. Coil Insulation Class – H Degree of protection applies to complete assembly composed of valve and coil, with electrical wiring according to IP 65.

Protection class IP/NEMA IP 65 (with connector)

Temperature Ambient/Media (°C) Ambient: -20 … +60 Fluid: -20 … +80 Ambient: -20 … +60 Fluid: -20 … +80 Ambient: -20 … +60 Fluid: -20 … +80

Electrical connection Connector M20 x 1,5

Weight (kg) 0,35

Connector M20 x 1,5

0,36

Connector M20 x 1,5

0,36

Temperatures mentioned refer to coils only. This coil has a fuse with an appropriate rating. Electrical connector – terminal type (with metal cable entry). For other power coils please contact Engineering Team.

Accessories Inlet filter

Silencer (plastic) *2)

Silencer (stainless steel) *2)

Silencer (brass) *2)

Exhaust guard *3)

0681173 (G1/4, 1/4 NPT)

C/S2 (1/4 NPT)

0613678 (1/4 NPT)

MS002A (1/4 NPT)

0613422 (G1/4, 1/4 NPT)

*2) For indoors use only. *3 For outdoors use, opening pressure 0,2 bar.


ICO3S Technical features

• Electromagnetically actuated, direct solenoid operated. 1/4 NPT

Medium: Hydraulic and pneumatic – customer to specify and confirm compatibility Operating pressure: 0 … 12 bar (0 … 174 psi) Fluid temperature: -55°C … +69°C (-67°F … 156°F)

Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: high NBR

1 VALVES

• 3/2 Exia poppet valves

Reliable and long life, ideal for a one time installation

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

SIL2 @ HFT=0 SIL3 @ HFT=1

Symbol

2

57

Technical data - standard models Port size

Function

Operating pressure (bar)

Manual override/ reset

Conduit connection

ATEX

Temperature range Media Ambient (°C) (°C)

YX13AA1H1BS

1/4 NPT

3/2 NC

0 … 12

Without

M20 x 1,5

Ex II 2 GD, Ex ia IIC

-55 … +69°C

-55 … +69°C

5/2

0 … 12

Without

M20 x 1,5

Ex II 2 GD, Ex ia IIC

-55 … +69°C

-55 … +69°C

V-32C-E-F 1

3 4

2

2

4

1/4 NPT

V-52-E-F

513

1

YX15AA1H1BS

3

V-32C-EH-F

2

2

V-52-EH-F

Technical data 5 1 3 – Solenoids V-32C-ER-F 14 32 Nominal voltages Pull-in voltage

513

24 V d.c. via an energy limiting barrier

V-52-EH-F

≥ 87,5% of nominal

Response times

Pull-in 3 … 4 seconds, drop out < 60 ms

Drop-out voltage

10 … 20% of nominal

Coil rating

293 ohms

Power consumption

0,43 watts typical

Voltage protection

Surge suppression diodes fitted as standard

Coil encapsulation

Class H

Leak performance

Bubble tight at 50°C < 30 cc/m at -55°C

Coil duty cycle

100%

For further information www.imi-precision.com

Model


1

ICO3S

VALVES

Reliable and long life, ideal for a one time installation

• 3/2 or 5/2 poppet valves

Technical features

• Electromagnetically actuated, direct solenoid operated. 1/4 NPT … 1/2 NPT

Medium: Hydraulic and pneumatic – customer to specify and confirm compatibility Operating pressure: 0 … 12 bar (0 … 174 psi) Fluid temperature: -55°C … +90°C (-67°F … +194°F) Ambient temperature: See table.

Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: NBR Other seal materials available on request

SIL2 @ HFT=0 SIL3 @ HFT=1

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

58

Technical data – standard models with conduit connection M20 x 1,5 Symbol

For further information www.imi-precision.com

Model

Port size

Function

Operating pressure (bar)

Manual override/ reset

ATEX certification

Power consumption at 24 Vdc (W)

Ambient temperature

Y013AA1H1BS

1/4 NPT

3/2 UNI

0 … 12

Without

Ex II 2 GD, Exd IIC

3

T6 (-55 … +50°C), T4 (+90°C max)

Y013AA3H1BS

1/2 NPT

3/2 UNI

0 … 12

Without

Ex II 2 GD, Exd IIC

7,8

T6 (-55 … +50°C), T4 (+90°C max)

Y015AA1H1BS

1/4 NPT

5/2 UNI

0 … 12

Without

Ex II 2 GD, Exd IIC

7,8

T6 (-55 … +50°C), T4 (+90°C max)

1/2 NPT

5/2 UNI

0 … 12

Without

Ex II 2 GD, Exd IIC

7,8

T6 (-55 … +50°C), T4 (+90°C max)

2

V-32C-E-F

1

3 2

1

4

3

2

V-52-E-F

25 1 3 1

4

3

V-32C-EH-F

2

Y015AA3H1BS

V-32C-ER-F V-52-EH-F

513 4

2

V-52-EH-F 513


ICO4S Technical features Medium: Hydraulic and pneumatic – customer to specify and confirm compatibility Operating pressure: 0 … 20 bar (0 … 290 psi) Fluid temperature: -20°C … +90°C (-4°F … +194°F) Options to -60°C (-76°F) Cavailable on request

Ambient temperature: See table. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: high NBR

SIL2 @ HFT=0 SIL3 @ HFT=1

Port size

Function

Operating pressure (bar)

Material Seat seal

Manual override/ reset

ATEX certification

Power consumption 24 V d.c. (W)

Ambient temperature

Y123AA1H1BS

1/4 NPT

3/2 UNI

0 … 20

NBR

Without

Exd IIC T6

4,5

T6 (-60 … +48°C), T4 (-60 … +90°C )

1/2 NPT

3/2 UNI

0 … 20

NBR

Without

Exd IIC T6

9,6

T6 (-60 … +48°C), T4 (-60 … +90°C )

V-32C-EH-F1/4 NPT V-52-E-F

5/2 UNI

0 … 20

NBR

Without

Exd IIC T6

9,6

T6 (-60 … +48°C), T4 (-60 … +90°C )

V-32C-E-F

Y123AA3H1BS

3 2

4

1

2

3

513 2 4 2

1 3 513 4

Y125AA3H1BS

V-32C-ER-F V-52-EH-F

2

V-52-EH-F 513

For further information www.imi-precision.com

Model

2 1

59

Technical data – standard models with conduit connection M20 x 1,5 Symbol

1 VALVES

• 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled. 1/4 NPT

Reliable and long life, ideal for a one time installation


Introducing ICO4-PST The first smart solenoid valve with fully integrated partial stroke testing Working closely with customers in the global oil and gas industry, we see the need for a no compromise solution for partial stroke testing. It is clear that the best way to eliminate the compromises of positioner systems is to use the control mechanism of the electronic solution; whilst the best way to eliminate the compromises of the electronic solution is to employ the packaging of the positioner system.

Find out more www.imi-precision.com

Now add to this the benefits of using a high integrity solenoid valve and we are left with a clear path – namely, the integration of the PST control electronics into the termination housing of a high integrity solenoid valve. Working closely with customers in the global oil and gas industry, we see the need for a no compromise solution for partial stroke testing. It is clear that the best way to eliminate the compromises of positioner

systems is to use the control mechanism of the electronic solution; whilst the best way to eliminate the compromises of the electronic solution is to employ the packaging of the positioner system. Now add to this the benefits of using a high integrity solenoid valve and we are left with a clear path – namely, the integration of the PST control electronics into the termination housing of a high integrity solenoid valve.


Compatible with Redundant Valve Manifold

Compatible with hydraulic actuators

Simplifies engineering process

Ideal for retrofit

The ICO4-PST is the first fully integrated partial stroke testing solution with the control system built into the market leading IMI Maxseal ICO4 high integrity solenoid valve. With the lowest safe and dangerous failure rates of any intelligent PST system on the market and always providing the highest possible Diagnostic Coverage, the best possible SIL performance is guaranteed.

> No dedicated PST device required therefore significantly reduces engineering requirements > High level diagnostics with position, pressure and time monitoring > Simple Pass/Fail reporting > Dual override mechanism eliminates possibility of over-stroke

> Compatible with valve speeds from 2 to 120 seconds > SIL 3 certified as 1oo1 > -40°C ‌ +60°C > Local testing using HART 475 communicator, remote testing via HART

Engineering GREAT Solutions


Fully flexible manifold options available

ICO4-PST The flexible solution Another product of our innovation and technical excellence, the ICO4-PST is reliable and flexible, and can be designed to your specification. Manifold options are available depending specific environmental and application requirements.

> Solenoid configurations > 1oo1, 1oo2, 2oo2, 2oo3

> Valves > Ball, butterfly, gate, globe, HIPPS

> High flow rate Cv up to 5.0 > Reduces requirements for QEVs, pilot valves & boosters

> Valve Speeds > 2s to 120s

> Actuator Types > Pneumatic, hydraulic > Spring return > Quarter turn, linear

> Operating temperature range > -40°C … +60°C > Retrofit > Ideal for retrofit applications due to engineering simplicity

Engineering GREAT Solutions

Find out more www.imi-precision.com


ICO4-PST • Partial Stroke Testing integrated into the ICO4 valve

Technical features Medium: Pneumatic – customer to specify and confirm compatibility Operation: Direct solenoid operated poppet valves with integral pressure transmitter Operating pressure: 0 … 10 bar (0 … 145 psi) Mounting position: Solenoid vertical Ambient temperature: 1/4 … 1/2 NPT resp. G1/4 … 1/2 -40°C … +60°C 3/4 NPT resp. G3/4 -40°C … +50°C

Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: NBR/FPM

Dramatically reduces engineering requirements

Other seal materials available on request

SIL2 @ HFT=0 SIL3 @ HFT=1

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

P

1

3 2

C

Model

Port size

Cv

Conduit connection

Material Seat seal

Y413AA1H2BS

1/4 NPT

0,8

1/2 NPT

NBR

Y413AE1H1BS

G1/4

0,8

M20 x 1,5

NBR

Y413AA3H2BS

1/2 NPT

2,1

1/2 NPT

NBR

Y413AE3H1BS

G1/2

2,1

M20 x 1,5

NBR

Y413AA5H2BS

3/4 NPT

5

1/2 NPT

NBR

Y413AE5H1BS

G3/4

5

M20 x 1,5

NBR

P

1

3 2

C

P

Electrical details 1

ATEX details

3

Voltage:

24 V d.c.

Certification:

Ex db IIC T4/T6

Voltage tolerance Power consumption:

±12,5% of Nominal

Model: Ambient temperature:

Insulation class

Class H

ICO4E T4: 1/4 … 1/2 NPT resp. G1/4 … 1/2 -40 … +60°C (-40 … +140°F) 3/4 NPT resp. G3/4 -40 … +50°C (-40 … +122°F) T6: -40 … +43°C (-40 … +110°F)

Conduit connection IP-Protection class EN 60529

1/2 NPT or M20 x 1,5 IP66

Additional Global Approvals:

In-Metro, TR CU, Class I Div 1 FM3600 / FM3615 / CSA 22.2

Rating: Charging (~4 Mins) 6,7 W (1/4”); 9,7 W (1/2”), 17,4 W (3/4”) Steady-State 5,7 W (1/4”); 8,7 W (1/2”), 16,4 W (3/4”)

For further information www.imi-precision.com

2 C

63

Technical data – standard models Symbol

VALVES

• 3/2 Smart solenoid poppet valves; 1/4 NPT … 3/4 NPT, G1/4 … G3/4

1


1

82400 & 82730

VALVES

• Indirect solenoid actuated diaphragm valves

Solenoid interchangeable without tools (Click-on®)

Technical features Medium: Neutral gases and liquids (82400) Slightly aggressive gases and liquids (82730) Flow direction: Fixed Operating pressure: 0,1 … 16 bar (1,4 … 232 psi) for Details, See table Temperature: Fluid -10°C … +90°C (14°F … +194°F) max. Ambient -10°C … +50°C (14°F … +122°F) max.

• 2/2 N/C, G1/4 … G2

Materials: Body: Brass (82400) or Stainless steel (82730) Seat Seal: NBR Internal parts: Stainless steel, PVDF, For contaminated fluids installations of a strainer is recommended

Models 64

Brass – For neutral, gases and liquids Symbol

Model

For further information www.imi-precision.com

A P

Orifice (mm)

Port size

Kv-value *1) (m3/h)

Operating pressure (bar)

8240000.9101.02400

8

G1/4

1,9

0,1 … 16

8240100.9101.02400

10

G3/8

3

0,1 … 16

8240200.9101.02400

12

G1/2

3,8

0,1 … 16

8240300.9101.02400

20

G3/4

6,1

0,1 … 16

8240400.9101.02400

25

G1

9,5

0,1 … 16

8240500.9101.02400

32

G1 1/4

23

0,1 … 10

8240500.9151.02400

32

G1 1/4

23

0,1 … 16

8240600.9101.02400

40

G1 1/2

25

0,1 … 10

8240600.9151.02400

40

G1 1/2

25

0,1 … 16

8240700.9101.02400

50

G2

41

0,1 … 10

8240700.9151.02400

50

G2

41

0,1 … 16

Model

Orifice (mm)

Port size

Kv-value *1) (m3/h)

Operating pressure (bar)

8273000.9101.02400

8

G1/4

1,9

0,1 … 16

8273200.9101.02400

12

G1/2

3,8

0,1 … 16

8273300.9101.02400

20

G3/4

6,1

0,1 … 16

8273400.9101.02400

25

G1

9,5

0,1 … 16

8273500.9101.02400

32

G1 1/4

23

0,1 … 10

8273500.9151.02400

32

G1 1/4

23

0,1 … 16

8273600.9101.02400

40

G1 1/2

25

0,1 … 10

8273600.9151.02400

40

G1 1/2

25

0,1 … 16

8273700.9101.02400

50

G2

41

0,1 … 10

8273700.9151.02400

50

G2

41

0,1 … 16

*1) Cv-value (US) ≈ kv value x 1,2.

Stainless steel – For aggressive gases and liquids Symbol

A P

*1) Cv-value (US) ≈ kv value x 1,2.


82400 & 82730

1 Electrical details for all solenoid systems

Voltage and Frequency Solenoid 9101 *2) Code Voltage 024

Code Frequency 00

Voltage

24 V DC

Frequency

Power consumption Inrush- Holdingpower power 8W

8W

024

50

24 V AC

50 Hz

15 VA

12 VA

110

50

110 V AC

50 Hz

15 VA

12 VA

120

60

120 V AC

60 Hz

15 VA

12 VA

230

50

230 V AC

50 Hz

15 VA

12 VA

Design

DIN VDE 0580

Voltage range

±10%

Duty cycle

100% ED

Protection

EN 60529 IP65

Connector

Form A to DIN EN 175301-803 (included)

VALVES

Solenoids

According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.

Voltage and Frequency Solenoid 9151 *2) 024

00

24 V DC

18 W

18 W

024

50

24 V AC

50 Hz

45 VA

35 VA

110

50

110 V AC

50 Hz

45 VA

35 VA

120

60

120 V AC

60 Hz

45 VA

35 VA

230

50

230 V AC

50 Hz

45 VA

35 VA

*2)

Voltage.

Other functions and operating voltages available on request

65

Additional solenoid systems Protection

Solenoid

Standard voltage

II 2GD

EEx m II T4 T 130°C with 3 m Connection cable

9136

24 V DC, 110 V AC, 230 V AC

II 2G II 2D

Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db

6126

24 V DC, 110 V AC, 230 V AC

II 2G II 2D

Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db

6120

24 V DC, 110 V AC, 230 V AC

II 2G II 2D

Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db

6106

24 V DC, 110 V AC, 230 V AC

Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.

For further information www.imi-precision.com

ATEX Category


1

82470

VALVES

• Indirect solenoid actuated diaphragm valves

Solenoid interchangeable without tools (Click-on®)

Technical features Medium: Hot water and steam Flow direction: Fixed Operating pressure: 0,1 … 10 bar (1,4 … 145 psi) for Details, See table Temperatur: Fluid 0°C … +150°C (32°F … +302°F) max. Ambient -10°C … +60°C (14°F … +140°F) max.

• 2/2 N/C, G1/4 … G1

Materials: Body: Brass Seat seal: HNBR Internal Parts: Stainless steel, Brass For contaminated fluids installations of a strainer is recommended.

Models 66

Brass For neutral gases and liquids Symbol

For further information www.imi-precision.com

A P

Model

Orifice (mm)

Port size

Kv-value (m3/h)

Operating pressure (bar)

8247000.9100.00000

8

G1/4

1,7

0,1 … 10

8247100.9100.00000

10

G3/8

2,7

0,1 … 10

8247200.9100.00000

12

G1/2

3,4

0,1 … 10

8247300.9100.00000

20

G3/4

5,5

0,1 … 10

8247400.9100.00000

25

G1

8,5

0,1 … 10

Solenoids

Electrical details for all solenoid systems

Voltage and Frequency Solenoid 9101 *1) Code Voltage

Code Frequency

Voltage

Frequency

Design

DIN VDE 0580

Power consumption Inrush- Holdingpower power

Voltage range

±10%

Duty cycle

100% ED

Protection

EN 60529 IP65

Connector

Form A to DIN EN 175301-803 (included)

024

00

24 V DC

-

8W

8W

024

50

24 V AC *2)

50 Hz

15 VA

12 VA

110

50

110 V AC *2)

50 Hz

15 VA

12 VA

120

60

120 V AC *2)

60 Hz

15 VA

12 VA

230

50

230 V AC *2)

50 Hz

15 VA

12 VA

*1) Voltage. *2) A.c. only with rectifier plug.

Other functions and operating voltages available on request

According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.


82540, 82590 Solenoid interchangeable without tools (Click-on®) • Solenoid actuated diaphragm valve with forced lifting • 2/2 N/C, G1/4 … G2

Models - Brass Symbol

A P

VALVES

Technical features Medium: Neutral gases and liquids (82540) Slightly aggressive, gases and liquids (82590) Flow direction: Fixed Operating pressure: 0 … 10 bar (0 … 145 psi) Temperatur: Fluid -10°C … +90°C (14°F … +194°F) max. Ambient -10°C … +50°C (14°F … +122°F) max.

1

Materials: Body: Brass (82540) Stainless steel (82590) Seat Seal: NBR-K Internal Parts: Stainless steel, PVDF, Brass For contaminated fluids installations of a strainer is recommended.

Model Solenoid in V d.c.

Solenoid in V a.c.

Orifice (mm)

Port size

Kv-value (m3/h)

Operating pressure (bar)

8254000.9151.00000

8254000.9154.00000

8

G1/4

1,9

0 … 10

8254100.9151.00000

8254100.9154.00000

10

G3/8

3

0 … 10

8254200.9151.00000

8254200.9154.00000

12

G1/2

3,4

0 … 10

8254300.9151.00000

8254300.9154.00000

20

G3/4

5,8

0 … 10

8254400.9151.00000

8254400.9154.00000

25

G1

8

0 … 10

8254500.9401.00000

8254500.9404.00000

32

G1 1/4

23

0 … 16

8254600.9401.00000

8254600.9404.00000

40

G1 1/2

25

0 … 16

8254700.9401.00000

8254700.9404.00000

50

G2

41

0 … 16

Orifice (mm)

Port size

Kv-value (m3/h)

Operating pressure (bar)

Models - Stainless steel Model

A

8259000.9154.00000

8

G1/4

1,9

0 … 10

8259100.9150.00000

8259100.9154.00000

10

G3/8

3

0 … 10

8259200.9150.00000

8259200.9154.00000

12

G1/2

3,4

0 … 10

8259300.9150.00000

8259300.9154.00000

20

G3/4

5,8

0 … 10

8259400.9150.00000

8259400.9154.00000

25

G1

8

0 … 10

8259500.9401.00000

8259500.9404.00000

32

G1 1/4

23

0 … 16

8259600.9401.00000

8259600.9404.00000

40

G1 1/2

25

0 … 16

8259700.9401.00000

8259700.9404.00000

50

G2

41

0 … 16

Solenoids

Electrical details for all solenoid systems

Voltage and Frequency Solenoid 9151/9154 *1) Code Voltage

Code Voltage Frequency

Frequency

Power consumption Inrush- Holdingpower power

024

00

24 V DC

-

18 W

18 W

024

49

24 V AC

40 … 60 Hz 20 VA

20 VA

110

49

110 V AC

40 … 60 Hz 20 VA

20 VA

120

49

120 V AC

40 … 60 Hz 20 VA

20 VA

230

49

230 V AC

40 … 60 Hz 20 VA

20 VA

Design

DIN VDE 0580

Voltage range

±10%

Duty cycle

100% ED

Protection

EN 60529 IP65

Connector

Form A to DIN EN 175301-803 (included)

According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.

Additional solenoid systems

Voltage and Frequency Solenoid 9301/9304 *1) 024

00

24 V DC

-

18 W

18 W

024

49

24 V AC

50 Hz

20 VA

20 VA

110

49

110 V AC

50 Hz

20 VA

20 VA

120

49

120 V AC

60 Hz

20 VA

20 VA

230

49

230 V AC

50 Hz

20 VA

20 VA

Voltage and Frequency Solenoid 9401/9404 *1) 024

00

24 V DC

-

38 W

38 W

024

49

24 V AC

40 … 60 Hz 42 VA

42 VA

110

49

110 V AC

40 … 60 Hz 42 VA

42 VA

120

49

120 V AC

40 … 60 Hz 42 VA

42 VA

230

49

230 V AC

40 … 60 Hz 42 VA

42 VA

*1)

Voltage.

Other functions and operating voltages available on request

ATEX Category II 2GD

Protection EEx me II T3 T 140°C

Solenoid 9356

Standard voltage 24 V DC, 110 V AC, 230 V AC

II 3GD

EEx nA II T4 T 135°C

9326

24 V DC, 110 V AC, 230 V AC

II 3GD

EEx nA II T4 T 135°C

8426

24 V DC, 110 V AC, 230 V AC

II 2GD

EEx me II T3 T 140°C

8441

24 V DC, 110 V AC, 230 V AC

II 3GD

EEx nA II T4 T 135°C

9176

24 V DC, 110 V AC, 230 V AC

II 2GD

EEx me II T3 T 140°C

9191

24 V DC, 110 V AC, 230 V AC

II 3GD

EEx nA II T4 T 135°C

9426

24 V DC, 110 V AC, 230 V AC

II 2G II 2D II 2G II 2D II 2G II 2D

Ex eb mb IIC T3 Gb Ex mb tb IIIB T135°C Db IP65 Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db

6140

24 V DC, 110 V AC, 230 V AC

6240

24 V DC, 110 V AC, 230 V AC

6120

24 V DC, 110 V AC, 230 V AC

Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.

For further information www.imi-precision.com

P

8259000.9150.00000

67

Symbol


1

82960, 82970

VALVES

• 2/2-way diaphragm valves

Technical features

• G3/4 … 3, 3/4 … 2 1/2 NPT

Medium: Compressed air Flow direction: Fixed Operating pressure: 0,4 … 7/8 bar (5,8 … 101/116 psi) Dusty gas temperature: -20°C … +85°C (-4°F … +185°F) Cleaning gas temperature: -40°C … +85°C (-40°F … +185°F) Ambient temperature: -20°C … +85°C (-4°F … +185°F)

Solenoid interchangeable without tools (Twist-on®)

Materials: Body: Aluminium Seat Seal: TPE Internal Parts: TPU

Easy to maintain

Technical data - Standard models Symbol

A P

68

A P

For further information www.imi-precision.com

Model

Port size

Orifice (mm)

Valve length (mm)

Kv-value *1) (m3/h)

Operating pressure (bar)

8296300.8171.xxxxx

G3/4

20

95

18

0,4 … 8

8297300.8171.xxxxx

3/4 NPT

20

95

18

0,4 … 8

8296400.8171.xxxxx

G1

25

95

22

0,4 … 8

8297400.8171.xxxxx

1 NPT

25

95

22

0,4 … 8

8296600.8171.xxxxx

G1 1/2

40

135

59

0,4 … 8

8297600.8171.xxxxx

1 1/2 NPT

40

135

59

0,4 … 8

8296700.8171.xxxxx

G2

50

169

80

0,4 … 8

8297700.8171.xxxxx

2 NPT

50

169

80

0,4 … 8

8296800.8171.xxxxx

G2 1/2

65

169

93

0,4 … 8

8297800.8171.xxxxx

2 1/2 NPT

65

169

93

0,4 … 8

8296900.8171.xxxxx

G3

80

239,5

172

0,4 … 7

xxxxx Please insert voltage and frequency codes. *1) Cv-value (US) ≈ kv value x 1,2.

Solenoids

Electrical details for all solenoid systems

Voltage and Frequency Solenoid 8171 *2) Code Voltage

Code Frequency

Voltage

Frequency

Power consumption Inrush- Holdingpower power

024

00

24 V DC

-

12 W

12 W

024

50

24 V AC

50 Hz

23 VA

16 VA

110

50

110 V AC

50 Hz

23 VA

16 VA

120

60

120 V AC

60 Hz

23 VA

16 VA

230

50

230 V AC

50 Hz

23 VA

16 VA

*2)

Design

DIN VDE 0580

Voltage range

±10%

Duty cycle

100% ED

Protection

EN 60529 IP65

Connector

Form A to DIN EN 175301-803 (included)

According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.

Voltage.

Additional solenoid systems

Additional solenoid systems

ATEX Category

Protection

Solenoid

Standard voltage

Option

Solenoid

Standard voltage

II 3GD

EEx nA II T4 T 135°C

8176

24 V DC, 110 V AC, 230 V AC

Solenoid version for low temperature = 40°C

9151

24 V DC, 110 V AC, 230 V AC

II 2GD

EEx me II T4 T 140°C

8186

24 V DC, 110 V AC, 230 V AC

Pulse Solenoid

8821

24 V DC, 110 V AC, 230 V AC

8001

24 V DC, 110 V AC, 230 V AC

24 V DC, 110 V AC, 230 V AC

Solenoid version for low temperature = 40°C

II 2G II 2D

Ex eb mb IIC T4 Gb Ex mb tb IIIB T135°C Db

6176

Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.


82900, 82910 One-piece diaphragm

Technical features

• G3/4 … 3, 3/4 … 2 1/2 NPT

Medium: Compressed air Operating pressure: 0,4 … 7/8 bar (5,8 … 101/116 psi) Dusty gas temperature: -20°C … +85°C (-4ºF … +185°F) Cleaning gas temperature: -40°C … +85°C (-40ºF … +185°F) Ambient temperature: -40°C … +85ºC (-40ºF … +185ºF)

Materials: Body: Aluminium Seat Seal: TPE

Model

P

Z

A P

*1) Cv-value (US) ≈ kv value x 1,2.

Port size

Orifice (mm)

Valve length (mm)

Kv-value *1) (m3/h)

Operating pressure (bar)

8290300.0000.00000

G3/4

20

95

18

0,4 … 8

8291300.0000.00000

3/4 NPT

20

95

18

0,4 … 8

8290400.0000.00000

G1

25

95

22

0,4 … 8

8291400.0000.00000

1 NPT

25

95

22

0,4 … 8

8290600.0000.00000

G1 1/2

40

135

59

0,4 … 8

8291600.0000.00000

1 1/2 NPT

40

135

59

0,4 … 8

8290700.0000.00000

G2

50

170

80

0,4 … 8

8291700.0000.00000

2 NPT

50

170

80

0,4 … 8

8290800.0000.00000

G2 1/2

65

170

93

0,4 … 8

8291800.0000.00000

2 1/2 NPT

65

170

93

0,4 … 8

8290900.0000.00000

G3

80

239,5

144

0,4 … 7

For further information www.imi-precision.com

Z

A

69

Technical data - Standard models Symbol

1 VALVES

• 2/2-way diaphragm valves

Easy to maintain


1

85500, 85540

VALVES

• 2/2-way piston valves DN 15 … 50, Flange connection, Pressure rating PN 40

Forced lift / damped operation Technical features Medium: Neutral gases and liquids (85500) Slightly aggressive, gases and liquids (85540) Flow direction: Fixed Operating pressure: 0 … 25 bar (0 … 362 psi)

Fluid temperature: -20°C … +90°C (-4°F … 194°F) Ambient temperature: -20°C … +50°C (-4°F … 122°F) Materials: Body: Cast steel Brass (85500), Stainless steel (85540) Seat seal: NBR Internal parts: Stainless steel, PTFE/Carbon

Technical features - Standard models Symbol

A P

Model Solenoid in V DC

Model Solenoid in V AC

Orifice (mm)

Flow Kv value *1) (m3/h)

Operating pressure *2) (bar)

8550200.9401.xxxxx

8550200.9404.xxxxx

15

4,4

0 … 25

8550300.9401.xxxxx

8550300.9404.xxxxx

20

7

0 … 25

8550400.9401.xxxxx

8550400.9404.xxxxx

25

10,5

0 … 25

8550500.8401.xxxxx

8550500.8404.xxxxx

32

25

0 … 25

8550600.8401.xxxxx

8550600.8404.xxxxx

40

27

0 … 25

8550700.8401.xxxxx

8550700.8404.xxxxx

50

43

0 … 25

xxxxx Please insert voltage and frequency codes

*1) Cv-value (US) ≈ kv value x 1,2 *2) For gases and liquid fluids up tobis 60 mm2/s (cSt)

Technical features - Standard models Model Solenoid in V DC

Model Solenoid in V AC

Orifice (mm)

Flow Kv value *1) (m3/h)

Operating pressure *2) (bar)

8554200.9401.xxxxx

8554200.9404.xxxxx

15

4,4

0 … 25

8554300.9401.xxxxx

8554300.9404.xxxxx

20

7

0 … 25

A

8554400.9401.xxxxx

8554400.9404.xxxxx

25

10,5

0 … 25

8554500.8401.xxxxx

8554500.8404.xxxxx

32

25

0 … 25

P

8554600.8401.xxxxx

8554600.8404.xxxxx

40

27

0 … 25

8554700.8401.xxxxx

8554700.8404.xxxxx

50

43

0 … 25

Symbol

70

For further information www.imi-precision.com

xxxxx Please insert voltage and frequency codes

*1) Cv-value (US) ≈ kv value x 1,2 *2) For gases and liquid fluids up tobis 60 mm2/s (cSt)

Solenoids

Electrical details for all solenoid systems

Voltage and Frequency Solenoid 9401/9404 *3) Code Voltage

Code Frequency

Voltage

Frequency

Power consumption Inrush- Holdingpower power

024

00

24 V DC

-

38 W

38 W

024

49

24 V AC

40 … 60 Hz

42 VA

42 VA

110

49

110 V AC

40 … 60 Hz

42 VA

42 VA

120

49

120 V AC

40 … 60 Hz

42 VA

42 VA

230

49

230 V AC

40 … 60 Hz

42 VA

42 VA

Design

DIN VDE 0580

Voltage range

±10%

Duty cycle

100% ED

Protection

EN 60529 IP65

Connector

Form A to DIN EN 175301-803 (included)

According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.

Voltage and Frequency Solenoid 8401/8404 024

00

24 V DC

-

40 W

40 W

024

49

24 V AC

40 … 60 Hz

45 VA

45 VA

110

49

110 V AC

40 … 60 Hz

45 VA

45 VA

120

49

120 V AC

40 … 60 Hz

45 VA

45 VA

230

49

230 V AC

40 … 60 Hz

45 VA

45 VA

*3)

Voltage (With the expection of solenoid 94XX up to 41 V a.c.).

Other functions and operating voltages available on request

Additional solenoid systems ATEX Category

Protection

Solenoid

Standard voltage

II 2GD

EEx me II T3 T 140°C

8441

24 V DC, 110 V AC, 230 V AC

II 3GD

Ex nA II T4 T 135°C *4)

9426

24 V DC, 110 V AC, 230 V AC

II 3GD

Ex nA II T4 T 135°C *4)

8426

24 V DC, 110 V AC, 230 V AC

II 2GD

Ex d II C T4 und T5 T 130°C resp. T 95°C

8920

24 V DC, 110 V AC, 230 V AC

II 2G II 2D

Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db

6240

24 V DC, 110 V AC, 230 V AC

II 2G II 2D

Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db

6246

24 V DC, 110 V AC, 230 V AC

Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids. *4) Only d.c., for a.c. solenoids with design inspection certificate acc. to category 2, e.g. xxxxxxx.8436.


85780 Optimised flange design Technical features

• DN 15 … 100, flange connection

Suitable for use in single-channel safety-related systems in accordance with DIN EN 61508 / 61511 up to and including SIL 2 and up to and including SIL 3 in multichannel systems. Flow direction: Fixed Medium: Neutral gases and liquids (air, water, gases according to DVGW data sheet G 260 with seat seal FPM, oils and other fluids on request)

VALVES

• 2/2-way diaphragm valves

1

Operating pressure: 0 … 25 bar (0 … 362 psi) Fluid temperature: -10°C … +60°C (14ºF … 140°F) Ambient temperature: -10°C … +50°C(14ºF … 122°F) Materials: Body: up to DN 50: Stainless steel (1.4408) from DN 65: Stainless steel (1.4581) Seat seal: NBR Internal parts: Stainless steel, PTFE/ Carbon

Technical features - Standard models Symbol

Model Solenoid in V DC

A P

Model Solenoid in V AC

Orifice (mm)

Flow Kv value *1) (m3/h)

Operating pressure *2) (bar)

8578200.8401.xxxxx

8578200.8404.xxxxx

15

3,7

0 … 25

8578300.8401.xxxxx

8578300.8404.xxxxx

20

5,6

0 … 25

8578400.8401.xxxxx

8578400.8404.xxxxx

25

7,8

0 … 25

8578500.8401.xxxxx

8578500.8404.xxxxx

32

18

0 … 25

8578600.8401.xxxxx

8578600.8404.xxxxx

40

24,4

0 … 25

8578700.8401.xxxxx

8578700.8404.xxxxx

50

31,8

0 … 25

8578800.9504.xxxxx

65

67

0 … 25

8578900.9504.xxxxx

80

94

0 … 25

8579000.9501.xxxxx

8579000.9504.xxxxx

100

144

0 … 25

71

8578800.9501.xxxxx 8578900.9501.xxxxx

xxxxx Please insert voltage and frequency codes. *1) Cv-value (US) ≈ kv value x 1,2. *2) For gases and liquid fluids up tobis 60 mm2/s (cSt).

Electrical details for all solenoid systems

Voltage and Frequency Solenoid 8401/8404 Code Voltage

Code Frequency

Voltage

Frequency

Power consumption Inrush- Holdingpower power

024

00

24 V DC

-

40 W

40 W

024

49

24 V AC *3)

40 … 60 Hz

45 VA

45 VA

110

49

110 V AC *3)

40 … 60 Hz

45 VA

45 VA

120

49

120 V AC *3)

40 … 60 Hz

45 VA

45 VA

230

49

230 V AC *3)

40 … 60 Hz

45 VA

45 VA

Design

DIN VDE 0580

Voltage range

±10%

Duty cycle

100% ED

Protection

EN 60529 IP65

Connector

Form A to DIN EN 175301-803 (included)

According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.

Voltage and Frequency Solenoid 9501/9504 024

00

24 V DC

-

80 W

80 W

024

49

24 V AC *3)

40 … 60 Hz

89 VA

89 VA

110

49

110 V AC *3)

40 … 60 Hz

89 VA

89 VA

120

49

120 V AC *3)

40 … 60 Hz

89 VA

89 VA

230

49

230 V AC *3)

40 … 60 Hz

89 VA

89 VA

*3) A.c. only with rectifier plug.

Other functions and operating voltages available on request

Additional solenoid systems ATEX Category

Protection

Solenoid

Standard voltage

II 2GD

EEx me II T3 T 140°C

8441

24 V DC, 110 V AC, 230 V AC

II 2GD

Ex de IIC T4/T5 8900 Ex tD A21 IP65 T 130°C resp. T 95°C

24 V DC, 110 V AC, 230 V AC

II 2GD

Ex d IIC T4/T5 8920 Ex tD A21 IP65 T 130°C resp. T 95°C

24 V DC, 110 V AC, 230 V AC

II 3GD

Ex nA II T4 Ex tD A22 IP65 T 135°C

8426

24 V DC, 110 V AC, 230 V AC

II 2GD

Ex e mb II T3/T4 Ex tD A21 IP65 T 140°C

9540

24 V DC, 110 V AC, 230 V AC

II 2G II 2D

Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db

6240

24 V DC, 110 V AC, 230 V AC

II 2G II 2D

Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db

6246

24 V DC, 110 V AC, 230 V AC

Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.

For further information www.imi-precision.com

Solenoids


1

84500, 84520

VALVES

• Pressure actuated angle seat valves

Technical features

• 2/2 N/C, G1/2….G2

Medium: Neutral, gaseous and liquid fluids (84500) Agressives gaseous and liquid fluids (84520) Flow direction: Fixed Operating pressure: 0 … 16 bar (0 … 232 psi) See table Temperature: Fluid -10°C … +180°C (14°F … 356°F) max. Ambient -10°C … +60°C (14°F … 140°F) max.

Easy conversion to N/O or double acting without tools Materials: Body: Brass (84500) Stainless steel (84520) Seat seal: PTFE Internal parts: Brass, Stainless steel

72

Models Brass – For neutral, gases and liquids Symbol

For further information www.imi-precision.com

Z

A P

Model

Orifice (mm)

Port size

Kv value (m3/h)

Operating pressure (bar)

8450200.0000.00000

15

G1/2

4,8

0…16

8450300.0000.00000

20

G3/4

10

0…10

8450400.0000.00000

25

G1

14

0…10

8450500.0000.00000

32

G1 1/4

23

0…7

8450600.0000.00000

40

G1 1/2

30

0…4,5

8450700.0000.00000

50

G2

37

0…3

Stainless Steel – For agressive gaseous and liquid fluids Symbol

Z

A P

Model

Orifice (mm)

Port size

Kv value (m3/h)

Operating pressure (bar)

8452200.0000.00000

15

G1/2

4,8

0 … 16

8452300.0000.00000

20

G3/4

10

0 … 10

8452400.0000.00000

25

G1

14

0 … 10

8452500.0000.00000

32

G1/4

23,0

0…7

8452600.0000.00000

40

G1/2

30,0

0 … 4,5

8452700.0000.00000

50

G2

37,0

0…3

Suitable for contaminated fluids


V81, V82, V83 & V84 Bypass function for online servicing

Technical features

• G1/4, 1/4 NPT, G1/2, 1/2 NPT

Medium: Filtered, non-lubricated or dry compressed air, instrument air nitrogen and other nonflammable neutral dry fluids Operating pressure: V81, V82 & V83: 1 … 10 bar (145 psi) 2 … 8 bar (with 98025 Valves) V84: 12 bar (174 psi) 10 bar (145 psi) with CSA approval Additional filter: Installation of an in-line filter is recommended (in the direction of flow from the actuator to the RVM)

• International approvals • Three design options: Compact, semi-modular and modular • Aluminium or stainless steel construction For specific valve technical information please go to the relevant valve series pages.

1 VALVES

• Redundant valve manifold system

Outdoor installation

Ambient/Media temperature: V81,V82 & V83: Up to -40°C … +80°C V84: Up to -55°C to +80°C (-67°F … +176°F), See option selectors. Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below +2°C (35°F). For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP66 protection must be used!

1oo2, 2oo2 and 2oo3 increased safety & availability

Functionality options The RVM System is available in three functionality options, the selection of which will be dependent on the Safety Instrumented Function (SIF) that it is to be used within. 1oo2, 2oo2 double channel and uniquely 2oo3 triple channel systems are available.

73

Compact 1oo2 (V82 & V84)

Semi modular 1oo2 (V87 & V88)

Modular 1oo2 (with bypass) (V81 & V83)

1oo2 “Safety” Double channel redundant system

Compact 2oo2 (V82 & V84)

Semi modular 2oo2 (V87 & V88)

Modular 2oo2 (with bypass) (V81 & V83)

2oo2 “Availability” Double channel redundant system Redundancy for the process valve closure. Any one out of two solenoid valves needs to de-energise to ensure safety.

Compact 2oo3 (V82 & V84)

Semi modular 2oo3 (V87 & V88)

Modular 2oo3 (with bypass) (V81 & V83)

2oo3 “Safety and Availability” Triple channel redundant system Redundancy for the process valve closure. Any one out of two solenoid valves needs to de-energise to ensure safety.

For further information www.imi-precision.com

Redundancy for the process valve closure. Any one out of two solenoid valves needs to de-energise to ensure safety.


1

V81 & V82

VALVES

Option selector

V8˙˙˙˙˙˙˙4˙˙0000

74

For further information www.imi-precision.com

Models Modular with bypass Compact Valve function 1oo2 normally closed 2oo2 normally closed 2oo3 normally closed Port sizes G1/4 (Standard flow, 24011/24010) 1/4 NPT (Standard flow, 24011/24010) G1/2 (High flow, 98015/98025) 1/2 NPT (High flow, 98015/98025) Valve type Temperature 24011 series Aluminium -40°C … +60°C Stainless steel -40°C … +60°C Aluminium with -25°C … +70°C proximity sensor Stainless steel with -25°C … +70°C proximity sensor Aluminium -25°C … +80°C Stainless steel -25°C … +80°C 98015 series Aluminium -25°C … +60°C Stainless steel -25°C … +60°C Aluminium with -25°C … +60°C proximity sensor Stainless steel with -25°C … +60°C proximity sensor 24010 series Aluminium -25°C … +60°C Stainless steel -25°C … +60°C Aluminium with -25°C … +60°C proximity sensor Stainless steel with -25°C … +60°C proximity sensor 98025 series Aluminium -25°C … +60°C Stainless steel -25°C … +60°C

Substitute 1 2 Substitute 1 3 5 Substitute 11 12 23 24 Substitute V81 V82 011 010 022 020 033 030

Country of manufacture IMI internal use

-40°C … +80°C 2,5 … 10 bar

Silencers *1)

Temperature

Substitute

382402400

-20 … +60

FM/CSA

02

382512060

-20 … +60

FM/CSA

03

382602400

-20 … +60

FM/CSA

04

-20 … +60

FM/CSA

05

044

040

382712060 427002400

-40 … +65/55

ATEX/IECEX

08

053 064

050 060

427123050

-40 … +65/55

ATEX/IECEX

09

467002400

-40 … +70/40

ATEX/IECEX

14

467123050

-40 … +70/40

ATEX/IECEX

15

467202400

-40 … +70/40

ATEX/IECEX

16

467323050

-40 … +70/40

ATEX/IECEX

17

487202400

-40 … +50/40

ATEX/IECEX

18

487323050

-40 … +50/40

ATEX/IECEX

19

-40 … +70/55

ATEX/IECEX

55

-40 … +60

ATEX/IECEX

40

073 084 093

070 080 090

104

100

Instrinsically safe versions 213 224 233

210 220 230

244

240

313 324

310 320

Series 24010 2003 Series 98025*3) 2050

*1) Other indicators or silencers can be ordered separately *2) Temperature depending on Ex classification *3) Other solenoids and currents available on request

V81 Flow rates and valve combinations

Temperature (°C) Materials

Weight (kg)

Model

Flow direction (port to port)

-25 … +80°C -25 … +60°C

Aluminium Aluminium

9,5 kg 9,8 kg

V811120534**0000 V811240734**0000

-25 … +80°C -25 … +60°C

Aluminium Aluminium

9,6 kg 9,9 kg

V813120534**0000 V813240734**0000

-25 … +80°C -25 … +60°C

Aluminium Aluminium

15,7 kg 15,9 kg

V815120534**0000 V815240734**0000

1oo2 1 » 2 [l/min] *4) 2 » 3 [l/min] *5) 2oo2 1 » 2 [l/min] *4) 2 » 3 [l/min] *5) 2oo3 1 » 2 [l/min] *4) 2 » 3 [l/min] *5)

Standard flow systems (24011/24010) Bypass Operation mode mode 97109 2 x 24011 950 170 – 970 … 2200 97109 2 x 24011 950 240 – 950 … 2200 97109 4 x 24011 950 165 – 950 … 2200

High flow systems (98015/98025) Bypass Operation mode mode 97109 2 x 98015 1450 620 – 2800 … 4600 97109 2 x 98015 1450 720 – 2500 … 4600 97109 4 x 98015 1450 600 – 2500 … 4600

*4) Flow characteristics conforms to ISO6358 from port 1 (bypass valve) to port 2 (sub-base) [6 » 5 bar]. *5) Flow characteristics conforms to ISO6358 from port 2 (sub-base) to port 3 (sub-base or bypass valve) [10 » 0 bar].

V82 standard models

** Solenoid code.

Visual valve status indicators in stainless steel - included in the scope of supply

24011 series + 98015 *3)

** Solenoid code.

Port Valve size type 1oo2 (SIL 3) 1/4 NPT 2401109 1/2 NPT 9801595 2oo2 (SIL 2) 1/4 NPT 2401109 1/2 NPT 9801595 2oo3 (SIL 3) 1/4 NPT 2401109 1/2 NPT 9801595

Temperature / Pressure range

Exhaust guard - included in the -55°C … +80°C scope of supply Solenoids coil Temperature *2) EXStandard certificate (°C)

V81 standard models Port Valve size type 1oo2 (SIL 3) 1/4 NPT 2401109 1/2 NPT 9801595 2oo2 (SIL 2) 1/4 NPT 2401109 1/2 NPT 9801595 2oo3 (SIL 3) 1/4 NPT 2401109 1/2 NPT 9801595

Indicators *1) For V81

V82 Flow rates and valve combinations

Temperature (°C) Materials

Weight (kg)

Model

-25 … +80°C -25 … +60°C

Aluminium Aluminium

3,7 kg 4,4 kg

V821120504**0000 V821240704**0000

-25 … +80°C -25 … +60°C

Aluminium Aluminium

3,7 kg 4,4 kg

V823120504**0000 V823240704**0000

-25 … +80°C -25 … +60°C

Aluminium Aluminium

8,2 kg 9,3 kg

V825120504**0000 V825240704**0000

Flow direction (port to port) 1oo2 1 » 2 [l/min] *6) 2 » 3 [l/min] *7) 2oo2 1 » 2 [l/min] *6) 2 » 3 [l/min] *7) 2oo3 1 » 2 [l/min] *6) 2 » 3 [l/min] *7)

Standard flow systems (24011/24010) 2 x 24011 170 1000 2 x 24011 250 710 4 x 24011 190 710

High flow systems (98015/98025) 2 x 98015 750 3400 2 x 98015 1050 2690 4 x 98015 740 2420

*6) Flow characteristics conforms to ISO6358 from port 1 to port 2 (sub-base) [6 » 5 bar]. *7) Flow characteristics conforms to ISO6358 from port 2 (sub-base) to port 3 (sub-base) [10 » 0 bar].


V83 & V84

1

Option selector

Valve type

Substitute 3 4 Substitute 1 3 5 Substitute 11 12 23 24

Solenoid Voltage Protection

01 02 03 04 05 06 07 08 09 10 22 24 28 30 31 32 42 43 44

24V d.c. 24V d.c. 110V a.c. 24V d.c. 24V a.c. 125V d.c.

M20x1,5 1/2 NPT 1/2 NPT 1/2 NPT M20x1,5 1/2 NPT

21 25 26 29 33 45

24 V d.c. 24 V d.c. 230 V a.c. 230 V a.c. 24 V d.c. 24 V d.c. 230 V a.c. 230 V a.c. 110V a.c. 125V d.c.

M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT M20x1,5 1/2 NPT

12 13 14 15 17 18 19 20 39 41

1/2 NPT M20x1,5

Note; Please advise when ordering if CSA certification is required.

27 46

Substitute 2 4 Substitute 2 4 0

Flow rates and valve combinations Flow direction (port to port)

Standard flow systems Bypass mode Operation mode

High flow systems Bypass mode Operation mode

1oo2

97109

2 x Y*13ANPH*BS

97109

2 x Y*13AMMH*BS

1 » 2 *10) [l/min]

950

330

1450

740

2 » 3 *11) [l/min]

1740 … 2200

3200 … 4600

2oo2

97109

2 x Y*13ANPH*BS

97109

2 x Y*13AMMH*BS

1 » 2 *10) [l/min]

950

490

1450

810

2 » 3 *11) [l/min]

1640 … 2200

2500 … 4600

2oo3

97109

4 x Y*13ANPH*BS

97109

4 x Y*13AMMH*BS

1 » 2 *10) [l/min]

950

320

1450

720

2 » 3 *11) [l/min]

1640 … 2200

2500 … 4600

*10) Flow characteristics conforms to ISO6358 from port 1 (bypass valve) to port 2 (sub-base) [6 » 5 bar]. *11) Flow characteristics conforms to ISO6358 from port 2 (sub-base) to port 3 (sub-base or bypass valve) [10 » 0 bar].

For further information www.imi-precision.com

M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT M20x1,5 M20x1,5 1/2 NPT 1/2 NPT 1/2 NPT M20x1,5 1/2 NPT 1/2 NPT 1/2 NPT

110V a.c. 24V d.c.

Silencers*9) Temperature Exhaust guard (standard) -55°C … +80°C Manifold material Stainless steel Aluminium Bypass valve (V83) Temperature Stainless steel -40°C … +60°C Stainless steel -25°C … +80°C No bypass (V84) *8) other indicators or plugs can be ordered separately. *9) other silencers can be ordered separately.

Substitute

24 V d.c. 24 V d.c. 24 V d.c. 230 V a.c. 230 V a.c. 24 V d.c. 24 V d.c. 24 V d.c. 230 V a.c. 230 V a.c. 24V d.c. 24V d.c. 24V d.c. 125V d.c. 110V a.c. 110V a.c. 125V d.c. 110V a.c. 120V a.c.

Temperature / Pressure range -40°C … +80°C 2,5 … 10 bar

75

Standard flow YX13ANPH1BS Exia Y013ANPH1BS Exd YZ13ANPH1BS Exmbe Y013ANPH1MS Exd YZ13ANPH1MS Exmbe YX13ANPH2BS Exia Y013ANPH2BS Exd YZ13ANPH2BS Exmbe Y013ANPH2MS Exd YZ13ANPH2MS Exmbe Y013ANPH1BS-2W Exd Y013ANPV1BS-2W Exd Y013ANPH2BS-2W Exd Y013ANPH2ES Exd Y013ANPH2JS Exd Y013ANPH2JS Exd YZ13ANPH2ES Exmbe YZ13ANPH2JS Exmbe YZ13ANPH2TS Exmbe Standard flow (PBMR) Y013PNPH1BS Exd Y013PNPH2BS Exd Y013PNPH2JS Exd Y013PNPH2BS-2W Exd Y013PNPH1BS-2W Exd Y013PNPH2ES Exd High flow Y013AMMH1BS Exd YZ13AMMH1BS Exmbe Y013AMMH1MS Exd YZ13AMMH1MS Exmbe Y013AMMH2BS Exd YZ13AMMH2BS Exmbe Y013AMMH2MS Exd YZ13AMMH2MS Exmbe Y013AMMH1JS Exd Y013AMMH2ES Exd High flow (PBMR) Y013PMMH2JS Exd Y013PMMH1BS Exd

Cable Entry

Country of manufacture IMI internal use Indicators*8) For V83 Visual valve status indicators in stainless steel - included in the scope of supply

VALVES

V8˙˙˙˙˙˙˙˙000000

Models Modular with bypass Compact Valve function 1oo2 normally closed 2oo2 normally closed 2oo3 normally closed Port sizes G1/4 (Standard flow) 1/4 NPT (Standard flow) G1/2 (High flow) 1/2 NPT (High flow)


1

V81, V82, V83 & V84

VALVES

Accessories Standard (Included in the scope of supply) Exhaust guard *12)

Visual indicators (stainless steel) only for V81

0613422 (G 1/4, 1/4 NPT)

74749-61 (G 1/4)

–

74749-60 (1/4 NPT)

0613423 (G 1/2, 1/2 NPT)

–

Other silencers, plastic indicator and plugs (can be ordered separately) Silencer (stainless steel) *13)

Silencer (plastic) *13)

Visual indicators (plastic) Adaptor

Plug plus Sealing washer

76

For further information www.imi-precision.com

0014613 (G 1/4)

M/S2 (G 1/4)

5VS-212-000 (1/8 NPT)

0663943 (G 1/4, stainless steel)

0613678 (1/4 NPT)

C/S2 (1/4 NPT)

Adapter (1/8 NPT to 1/4 NPT) *14)

0682082 (1/4 NPT, stainless steel)

0014813 (G 1/2)

M/S4 (G 1/2)

0613659 (stainless steel)

0660835 (plastic) Sealing washer *15)

0613679 (1/2 NPT)

C/S4 (1/2 NPT)

*12) For outdoors use ~ 0,2 (bar). *13) For indoors use. *14) Must be ordered separately. *15) Must be ordered separately for G thread only.


80400 Suitable for installation in extreme low temperature, outdoor and off shore applications

Technical features Medium: Filtered, non-lubricated compressed air, instrument air, nitrogen or other nonflammable, neutral dry fluids Operating pressure: 0 … 10 bar (0 … 145 psi) Pilot pressure: 2 … 10 bar (29 … 145 psi) (≥ operating pressure) Fluid/Ambient temperature: -60°C … 80°C (-76°F … 176°F)

• 1/2 … 1 1/2 NPT or G1/2 … G1 1/2

Material: Housing, flange and inner parts: stainless steel 1.4404 (316 L) * Dynamic seals: PUR Static seals: PUR and NBR *C racking-resistant for use in H2S-contaminated environments (DIN EN ISO 15156-3:2005).

VALVES

• 3/2 way poppet valve pneumatically actuated

1

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F) For outdoor installation please protect all connections against the penetration of moisture! Please contact IMI Precision Engineering for operational conditions below -55°C

SIL2 @ HFT=0 SIL3 @ HFT=1

Symbol

77

Technical data Model

Port size 1

3

Flow *2) 1 » 2 2»3 (l/min) (l/min)

8040005

1/2 NPT

1/2 NPT

3/4 NPT

15

6700

7600

17200

19800

8040015

3/4 NPT

3/4 NPT

1 NPT

20

11500

14000

29000

35000

8040025

1 NPT

8040035 V-32C-L-F1 1/2 NPT

1

3

Flow *1) 1 » 2 2»3 (l/min) (l/min)

1 NPT

1 1/4 NPT

25

13900

14700

32300

39600

1 1/2 NPT

1 1/2 NPT

30

24700

30500

56800

72600

8040055

G1/2

G1/2

G3/4

15

6700

7600

17200

19800

8040065

G3/4

G3/4

G1

20

11500

14000

29000

35000

8040075

G1

G1

G1 1/4

25

13900

14700

32300

39600

8040085

G1 1/2

G1 1/2

G1 1/2

30

24700

30500

56800

72600

Flow conducted according to ISO 6358. In order to ensure full flow and proper function make sure that sufficient pressure supply with feed pipe diameters according to the port size is available. *1) Inlet pressure 6 bar, outlet pressure 5 bar. *2) Inlet pressure 10 bar, outlet pressure 0 bar.

For further information www.imi-precision.com

2

2

Nominal diameter (mm)


1

VALVES

78


2 I/P & E/P Converters

Reliable, rugged, certified control Explosion Proof

The Only ATEX IS Fail Freeze I/P

Failsafe

<0.13W Consumption


2

Fast Find Guide

I / P & E / P C ON V E R T E R S

140 Series

422 Series

Closed loop I/P Failsafe

0.2 … 1 bar ALU, ZI

Page 81

0.2 … 1 bar ZI

80

For further information www.imi-precision.com ALU

Aluminium

422 IS Series

Closed loop I/P Fail Freeze

ZI

Zinc Die-casting

VP10 Series

Closed loop I/P Fail Freeze

Page 82

0.2 …1 bar Zi

100X Series

Open loop I/P

Page 83

0.2 … 8 bar ZI

220 Series

Open loop I/P

Page 84

0 … 1 bar ZI

Page 85

0 … 1 bar ZI

Page 86


140 Failsafe Series Explosion Proof I/P

Technical features Medium: Oil free, dry air, min filtered to 50 µm; internal in-built air filter Output pressure: 0,2 … 1 bar (3 … 15 psi) 0,2 … 2 bar (3 … 30psi) Supply pressure: 1,2 … 10,3 bar (18 … 150 psi) Response time: < 1 second (from 0 … 90% or 90 … 10% of output pressure into a 0,5 litre load) Temperature sensitivity: Typically < 0,06% span/°C between -40°C … +85°C (-40°F … +185°F)

• G1/4 or 1/4 NPT • Tight Shut Off setting

Linearity independent: Typically <0.1%, guaranteed <0.2% Hysteresis independent: Typically <0.1%, guaranteed <0.2% Supply sensitivity: < 0,1 z of span for full supply pressure range Operating temperature: -40°C … +85°C (-40°F … +185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

FM

I.P. Rating: IP66, NEMA Type 4X Materials: Body: aluminium and zinc diecasting Diaphragms: NBR Black epoxy powder coating standard

APPROVED

I / P & E / P C ON V E R T E R S

• Current to pressure (I/P) electronic converter

2

Technical data - standard models Symbol

Certification

Port size

Output pressure

Conduit Entry

EX14001BJ4LE2

Cenelec only

G1/4

0,2 … 1 bar

M 20 x 1,5

EX14001BK4EE1

ATEX: Ex ia, Exd, Exn FM/CSA:I.S., N.I.

1/4 NPT

0,2 … 1 bar

1/2 NPT

81

Model Multi certified units only – IS/Type N/Exd

Options available: Output pressure monitoring gauge.

Input Signal

4 … 20 mA (two wire) Terminal voltage < 6,5 V at 20 mA

Failure Mode

Pressure falls to below 15 mbar (0,2 psi) in < 2 sec when input signal fails

Overload Protection

100 mA max overload current

Connections

1/2” NPT or M20; internal terminal block with capacity up to 2,5 mm2 conductor

Option selector Output pressure bar (psi)

EX140˙˙˙˙4˙˙˙ Substitute

Certification Triple certification/ triple agency

0,2 … 1 (3 … 15)

01

Cenelec only (M20x1,5)

0,4 … 2 (6 … 30)

02

Conduit Entry

Unit of Pressure

Substitute

1/2 NPT

Substitute E1 E2 Substitute E

Bar

B

M 20 Cenelec Only

Psi

P

Ports

KPa

K

G1/4

J

Kg/cm2

G

1/4 NPT

K

L Substitute

For further information www.imi-precision.com

Electrical parameters


2

422 Fail Freeze Series Fail Freeze I/P

I / P & E / P C ON V E R T E R S

• Current to pressure (I/P)

Technical features

• 1/4 NPT

Medium: Oil free, dry air, filtered to 5 µm Output pressure: 0,2 … 1 bar (3 … 15psi) Supply pressure: at least 0,7 bar (10 psi) above maximum required output pressure maximum 3 bar gauge Flow capacity: Up to 300NL/min Response time: < 8 sec (typically < 3 sec) from 10% … 90% of output pressure into a 0,5 litre volume < 8 sec (typically < 3 sec) from 90% … 10% of output pressure into a 0,5 litre volume Linearity: ≤0,5% of Span

• Hold last pressure on failure of signal

Hysteresis: ≤0,5% of Span Temperature sensitivity: Typically < 0,034% span/°C between -10°C and +60°C (+14°F and +140°F) Supply sensitivity: < 0,1% of span for full supply pressure range Operating temperature: -20°C … +70°C (-4°F … +158°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

I.P. Rating: IP65 Materials: Body: zinc diecasting passivated and epoxy painted Cover: Glass renforced PA Diaphragms: NBR

82

Technical data - standard models Symbol

Model

Port

Output pressure

For further information www.imi-precision.com

AC2100

1/4 NPT

0,2 - 1 bar

AC0100

1/4 NPT

3 - 15 psi

AC0138X

1/4 NPT

0,2 - 1,0 Kg/cm2

For other port sizes or options please contact your sales representative.

Electrical parameters Input Signal

4 - 20 mA (two wire). Terminal voltage typically 7,5 V at 20 mA

Failure Mode

Output pressure held at previous value when input signal fails; drift rate 0,02% in 30 seconds

Overload protection

100 mA max. overload current. Unit unaffected by short duration reverse current

Connections

30 mm square connector provided (DIN 43650, form A) mountable in 4 directions

Span/Zero

Independently adjustable up to 20% output range


422 IS Fail Freeze Series Technical features

• G1/4 or 1/4 NPT

Medium: Oil free, dry air, filtered to 5 µm Output pressure: 0,2 … 1 bar (3 … 15psi) Supply pressure: at least 0,7 bar above maximum required output pressure maximum 4 bar gauge Flow capacity: Up to 250 Nl/min I.P. Rating: IP65 with piped exhaust Linearity: ≤0,5% of Span Hysteresis: ≤0,5% of Span

I / P & E / P C ON V E R T E R S

• Current to pressure (I/P) Converter • The only ATEX IS Fail Freeze I/P on the market

2

ATEX IS I/P Converter EMC Compatibility: Compliant and CE marked in accordance with the EC Directive 2004/108/EC tested to BS EN 61000-6-2:2005 BS EN 61000-6-4:2007+ A11:2011 Ambient/Media temperature: -10°C … +70°C Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Materials Body: zinc diecasting passivated nd epoxy painted Cover: Glass reinforced PA Diaphragms: NBR

Technical data Symbol

Model

Port size

Output pressure

AC301PJ1

G1/4

3 … 15 psi

AC301PK1

1/4 NPT

3 … 15 psi

G1/4

0,2 … 1 bar

1/4 NPT

0,2 … 1 bar

83

AC301BJ1 AC301BK1

Electrical parameters 4 … 20 mA (two wire). Terminal voltage typically < 11 V at 20 mA

Failure Mode

Output pressure held at previous value when input signal fails; drift rate ≤ 0,2% of span in 5 minutes

Overload protection

30 mA max. overload current. Unit unaffected by reverse current

Connections

30 mm square connector provided (DIN 43650, form A) mountable in 4 directions

Span/Zero

Independently adjustable up to 15% output range

For further information www.imi-precision.com

Input Signal

Certification Certification Agency

ATEX Intrinsically safe

IECEx Intrinsically safe

Sira

II 1G Sira 03ATEX2007X

IECEx SIR 11.0095X

Ex ia IIC T4 Ga (Ta = -40 … +80°C)

Ex ia IIC T4 Ga (Ta = -40 … +80°C)

Ui = 28 V d.c. Ii = 110 mA Pi = 0,8 W Ci = 5 nF Li = 0,24 mH

Ui = 28 V d.c. Ii = 110 mA Pi = 0,8 W Ci = 5 nF Li = 0,24 mH

1G

Option selector Pressure range

AC301˙˙˙ Substitute

Special notes

Substitute

3 … 15 psi

P

Standard exhaust

0

0,2 … 1 bar

B

Capture bleed

1

Port sizes

Substitute

Junction box & C/B

2

G 1/4

J

1/4 NPT

K


2

VP10 Series

I / P & E / P C ON V E R T E R S

• Proportional pressure control valves (I/P)

Reliable, rugged, open loop control

Technical features Medium: Oil free, dry air, filtered to 5 µm Output pressure: 0,2 … 1 bar (2,9 … 14,5 psi) 0,2 … 6 bar (2,9 … 87 psi) 0,2 … 8 bar (2,9 … 116 psi) Supply pressure: At least 0,7 bar (10 psi) above maximum required output pressure. Up to 2 bar(29 psi) instruments: max 5 bar (72,5 psi). Up to 8 bar (116 psi) instruments: max 10 bar (145 psi). Response Time: < 0,35 seconds for 10 … 90% or 90 … 10% of output pressure into a 10cc load (1 bar (14,5psi) range instruments)

• G1/4

Temperature sensitivity: < 0,1% of span/°C between -40°C … +85°C (-40°F … +185°F) Supply sensitivity: < 0,075% span output change per % supply pressure change Operating temperature: -40°C … +85°C (-40°F … +185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C(+35°F)

I.P. Rating: IP65 in normal operation Materials: Body: Passivated zinc die-casting, epoxy painted Cover: Glass reinforced PA Diaphragms: NBR

84

Technical data - standard models Symbol

For further information www.imi-precision.com

Model

Port size

Flow (l/min)

Control signal

Output pressure (bar)

VP1001BJ400A00

G1/4

300

4 … 20 mA

0,2 … 1

VP1006BJ401A00

G1/4

300

4 … 20 mA

0,2 … 6

VP1008BJ401A00

G1/4

300

4 … 20 mA

0,2 … 8

Electrical parameters Input Signal

1 … 4 bar: 2 wire 4 … 20 mA 6 … 8 bar: 3 wire 4 … 20 mA +12 … 24 V

Failure Mode

Output pressure falls to zero signal state when electrical supply fails

Connections

30 mm square connector provided (DIN 43650, form A) mountable in four orientations

Option selector Pressure range

VP10˙˙˙˙˙0˙A00 Substitute

Power supply

Substitute

0,2 … 1 bar / 3 … 15 psi

01

None requied

0

0,2 … 2 bar / 3 … 30 psi

02

1

0,2 … 4 bar / 3 … 60 psi

04

12 / 24 V (Required for 6 & 8 bar units)

0,2 … 6 bar / 3 … 90 psi

06

Input signal

0,2 … 8 bar / 3 … 120 psi

08

0 … 10 V / 1 … 10 V

Unit of Measure

Substitute

4 … 20 mA

Substitute 1 4

bar

B

Port size

Substitute

psi

P

1/4 NPT

K

1/4 BSP

J


100X Series Reliable, rugged, certified control • Proportional pressure control valves (I/P) • 1/4 NPT

I / P & E / P C ON V E R T E R S

Technical features Medium: Oil free, dry air, filtered to 5 µm Output pressure: 0,2 … 1 bar (2,9 … 14,5 psi) 3 … 15 psi Supply pressure: At least 0,7 bar (10 psi) above maximum required output pressure. max 5 bar (72,5 psi) Flow capacity: > 300Nl/min forward & relief flow Air consumption: up to 1 bar (15 psi): 2,8 Nl/min Response Time: < 0,35 seconds for 10 …. 90% or 90 … 10% of output pressure into a 10cc load (1 bar (14,5psi) range instruments)

Temperature sensitivity: < 0,1% of span/°C between -40°C … +85°C (-40°F … +185°F) Supply sensitivity: < 0,075% span output change per % supply pressure change Operating temperature: -40°C … +85°C (-40°F … +185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

I.P. Rating: IP65 in normal operation Materials: Body: Passivated zinc die-casting, epoxy painted Cover: Glass reinforced PA Diaphragms: NBR

85

Technical data - standard models Symbol

Port

Output pressure

Input Signal

400100R

1/4 NPT

3 … 15 psi

4 … 20 mA

402100R

1/4 NPT

0,2 … 1 bar

4 … 20 mA

490100R

1/4 NPT

3 … 15 psi

4 … 20 mA

x

492100R

1/4 NPT

0,2 … 1 bar

4 … 20 mA

x

Electrical parameters Input Signal

1 … 4 bar: 2 wire 4 … 20 mA

Failure Mode

Output pressure falls to zero signal state when electrical supply fails

Connections

30 mm square connector provided (DIN 43650, form A) mountable in four orientations

Certification Typ 100X Intrinsically Safe Sira 02ATEX2002X SIRA (CENELEC ATEX approved) to EN60079

Ex ia IIC T4 Ga (Ta = -40° to +80 °C) Ui = 28 V, Ii = 59 mA, Pi = 0.633 W Ci = 0 Li = 10 mH

II 1G

ATEX intrinsically safe

For further information www.imi-precision.com

Model

For other port sizes or options please contact your sales representatives

Certification

2


2

220 Series < 6 milliwatts of power

I / P & E / P C ON V E R T E R S

• High performance OEM I/P

Technical features

• Extremely low power consumption

Medium: Oil free, dry air, filtered to 5 µm Output pressure: 0 … 1 bar (0 … 15 psi) Supply pressure: At least 0,4 bar (10 psi) above maximum required output pressure, maximum 10 bar (145 psi) gauge Air consumption: 1,5 Nl/min typical Linearity: ≤ 2,0% of span Hysteresis & deadband: Typical ≤ 0,35% of span Response time: < 650 ms 10 … 90% into a 3cc volume ≤ 300 ms 90 … 10% into a 3cc volume

• Minimal temperature and orientation effect • Compact and rugged • Patented technology • Fast response • Customisable to OEM applications

Temperature sensitivity: Typical 0,2% span/°C between -40°C and +85°C Air supply sensitivity: Typical < 1,5% of span for full supply pressure range Vibration effect: <2% of span for vibration level up to, 2g 20 … 150 Hz in any orientation I.P. Rating: IP 30 as standard or customised to suit customer requirements Mounting Position: Any, to suit customer requirements Connections: Customised to suit customer requirements Ambient/Media temperature: -40°C … +85°C (-40°F … 185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C(+35°F)

86

Electrical parameters

For further information www.imi-precision.com

Input Signal

0 … 1,7 mA - terminal voltage is 3,11 V at 1,7 mA

Loop Resistance

1,8 kΩ

Input Impedance

3,1 … 3,2 V at 1,7 mA

Failure Mode

Output pressure falls to Zero setting on loss of signal

Connections

Customised to suit customer requirements

Ordering information Option to special order Performance parameters tuned to specific requirements Ported or manifold mount base designed to application requirements Optional enclosures Application specific calibration and set-up


3 Pressure Switches & Sensors Gold plated contacts Off line Programming

Stainless steel housing

ATEX


3

Fast Find Guide

P R E S S U R E S WI T C H E S & S E N S OR S

Electro-mechanical Pressure Switches 18D ATEX

18D Hydraulic ATEX

G1/4 or Flange

-1 … 30 bar ALU

20D Allfluid ATEX

G1/4 or Flange

Page 89

5 … 420 bar ALU St

Page 91

-1 … 63 bar ALU

Electronic Pressure Switch 33D Hydraulic/ Allfluid G1/4 or Flange

0 … 630 bar ALU SS

Page 94

Electronic Pressure Sensor 18S Allfluid G1/4

88 0 … 800 bar SS

Page 96

For further information www.imi-precision.com ALU

Aluminium

SS

Stainless Steel

20D Hydraulic ATEX

G1/2

St

Steel

G1/4

Page 92

5 … 400 bar ALU

Page 93


18D ATEX Technical features

• -1 … 30 bar G1/4 & Flanged

For Ex applications conforming to Zone 2 (gases): II3G Ex nAC IIC T6 X and Zone 22 category (dusts): II3D Ex tD A22 IP65 (e.g. IP67) T80°C X. Medium: For neutral, non-inflammable gases and fluids Operation: Diaphragm Operating pressure: -1 … 30 bar (-14 … 435 psi)

Degree of protection: IP65 for DIN EN 175301-803 (DIN 43650) form A IP67 for M12 x 1 Electrical connection: DIN EN 175301-803 (DIN 43650) form A or M12 x 1 IEC 947-5-2 Fluid/Ambient temperature: 0°C … +80°C (0°F … +176°F) (FPM)

Microswitch with gold plated contacts

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Materials: Housing: Aluminium Sealing: FPM/brass O-ring: NBR

Symbol

89

Electrical connection acc. to DIN EN 175301-803, form A - connector included in the scope of supply. The Ex approval refers to the pressure switch in combination with the supplied plug. Pressure range *1) (bar)

Switching pressure difference Lower range Upper range (bar) (bar)

Max. Over pressure *2) (bar)

Switching cycles (1/min)

Materials Pressure sensor housing

Sealing

Port size

0880180

-1 … 0

0,15

0,18

80

100

Aluminium

FPM/BR/NBR

G1/4

0880280

0,2 … 2

0,20

0,35

80

100

Aluminium

FPM/BR/NBR

G1/4

0880380

0,5 … 8

0,35

0,85

80

100

Aluminium

FPM/BR/NBR

G1/4

0880480

1 … 16

0,40

1,20

80

100

Aluminium

FPM/BR/NBR

G1/4

0880680

1 … 30

1

5

80

100

Aluminium

FPM/BR/NBR

G1/4

0881180

-1 … 0

0,15

0,18

80

100

Aluminium

FPM/BR/NBR

Flange

0881280

0,2 … 2

0,20

0,35

80

100

Aluminium

FPM/BR/NBR

Flange

0881380

0,5 … 8

0,35

0,85

80

100

Aluminium

FPM/BR/NBR

Flange

0881480

1 ... 16

0,40

1,20

80

100

Aluminium

FPM/BR/NBR

Flange

0881680

1 ... 30

1

5

80

100

Aluminium

FPM/BR/NBR

Flange

For further information www.imi-precision.com

Model

*1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values. BR = brass

3 P R E S S U R E S WI T C H E S & S E N S OR S

• Electro-mechanical pressure switch

Microswitch approved by UL and CSA


3

18D ATEX

P R E S S U R E S WI T C H E S & S E N S OR S

Electrical connection M12x1 acc. to IEC 947-5-2 - connector are not included in delivery, max. allowable voltage 30 V. The pressure switch will loose the Ex approval when using other connectors than those listed in the data sheet. Symbol

Model

Pressure range *1) (bar)

Switching pressure difference Lower range Upper range (bar) (bar)

Max. Over pressure *2) (bar)

Switching cycles (1/min)

Materials Pressure sensor housing

Sealing

Port size

0880181

-1 ... 0

0,15

0,18

80

100

Aluminium

FPM/BR/NBR

G1/4

0880281

0,2 ... 2

0,20

0,35

80

100

Aluminium

FPM/BR/NBR

G1/4

0880381

0,5 ... 8

0,35

0,85

80

100

Aluminium

FPM/BR/NBR

G1/4

0880481

1 ... 16

0,40

1,20

80

100

Aluminium

FPM/BR/NBR

G1/4

0880681

1 ... 30

1

5

80

100

Aluminium

FPM/BR/NBR

G1/4

0881181

-1 ... 0

0,15

0,18

80

100

Aluminium

FPM/BR/NBR

Flange

0881281

0,2 ... 2

0,20

0,35

80

100

Aluminium

FPM/BR/NBR

Flange

0881381

0,5 ... 8

0,35

0,85

80

100

Aluminium

FPM/BR/NBR

Flange

0881481

1 ... 16

0,40

1,20

80

100

Aluminium

FPM/BR/NBR

Flange

0881681

1 ... 30

1

5

80

100

Aluminium

FPM/BR/NBR

Flange

*1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values.

90

Accessories for use with all 18D series switches

For further information www.imi-precision.com

Pressure port reducing nipple

Surge damper

Cover (via adjustment screw)

Connector

Connector M 12 x 1 90°

0574767 (brass)

0574773 (brass)

0554737

0570110

0523058 (2 m cable, 4-core)

0550083 (Stainless steel)

0553258 (Stainless steel)

0523053 (5 m cable, 4-core)

Connector M 12 x 1 straight

0523056 (90° without cable)

0523057 (2 m cable, 4-core) 0523052 (5 m cable, 4-core)

0523055 (without cable)


18D Hydraulic ATEX

Microswitch approved by UL and CSA

Technical features

• 5 ... 420 bar, G1/4 & Flange

For Ex applications conforming to Zone 2 (gases): II3G Ex nAC IIC T6 X and Zone 22 category (dusts): II3D Ex tD A22 IP65 (e.g. IP67) T80°C X. Medium: For neutral, self lubricating fluids,e.g. hydraulic oil, lube oil, light fuel oil Operation: Softseal piston

Microswitch with gold plated contacts

Degree of protection: IP65 for DIN EN 175301-803 (DIN 43650) form A IP67 for M12 x 1 Electrical connection: DIN EN 175301-803 (DIN 43650) form A or M12 x 1 IEC 947-5-2 Fluid/Ambient temperature: 0°C ... +80°C (0°F ... +176°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Materials: Housing: Aluminium/Steel Sealing: PTFE/NBR For accessories - please see page 76

Electrical connection acc. to DIN EN 175301-803, form A - connector included in the scope of supply. The Ex approval refers to the pressure switc h in combination with the supplied plug. Symbol

Switching pressure difference Lower range Upper range (bar) (bar)

Max. Over pressure *2) (bar)

Switching cycles (1/min)

Materials Pressure sensor housing

Sealing

Port size

0882180

5 ... 70

10,5

15

400

100

AL/Steel

PTFE/NBR

G1/4

0882280

10 ... 160

11

17

400

100

AL/Steel

PTFE/NBR

G1/4

0882380

25 ... 250

13

21

400

100

AL/Steel

PTFE/NBR

G1/4

0882480

40 ... 420

17

38

600

100

AL/Steel

PTFE/NBR

G1/4

0883180

5 ... 70

10,5

15

400

100

AL/Steel

PTFE/NBR

Flange

0883280

10 ... 160

11

17

400

100

AL/Steel

PTFE/NBR

Flange

0883380

25 ... 250

13

21

400

100

AL/Steel

PTFE/NBR

Flange

0883480

40 ... 420

17

38

600

100

AL/Steel

PTFE/NBR

Flange

*1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values.

Electrical connection M12 x 1 acc. IEC 947-5-2 - connector are not included in delivery, max. allowable voltage 30 V max.The pressure switch will loose the Ex approval when using other connectors than those listed in the data sheet. Symbol

Model

Pressure range *1) (bar)

Switching pressure difference Lower range Upper range (bar) (bar)

Max. Over pressure *2) (bar)

Switching cycles (1/min)

Materials Pressure sensor housing

Sealing

Port size

0882181

5 ... 70

10,5

15

400

100

AL/Steel

PTFE/NBR

G1/4

0882281

10 ... 160

11

17

400

100

AL/Steel

PTFE/NBR

G1/4

0882381

25 ... 250

13

21

400

100

AL/Steel

PTFE/NBR

G1/4

0882481

40 ... 420

17

38

600

100

AL/Steel

PTFE/NBR

G1/4

0883181

5 ... 70

10,5

15

400

100

AL/Steel

PTFE/NBR

Flange

0883281

10 ... 160

11

17

400

100

AL/Steel

PTFE/NBR

Flange

0883381

25 ... 250

13

21

400

100

AL/Steel

PTFE/NBR

Flange

0883481

40 ... 420

17

38

600

100

AL/Steel

PTFE/NBR

Flange

*1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values.

For further information www.imi-precision.com

Pressure range *1) (bar)

91

Model

P R E S S U R E S WI T C H E S & S E N S OR S

• Electro-mechanical pressure switch

3


3

20D Allfluid ATEX

Microswitch with gold plated contacts

P R E S S U R E S WI T C H E S & S E N S OR S

• Electro-mechanical pressure switch

Technical features

• -1 … 63 bar, G1/2

For Ex zones 1 and 2 (gases) category II2G type of protection Ex db eb IIC T6 For Ex zones 21 and 22 (dusts) category II2D type of protection Ex tb IIIC T80°C IP65

Degree of protection: IP65 (DIN 40050) Fluid/Ambient temperature: -10°C … +75°C (+14°F … 167°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Medium: For neutral, non-inflammable gases and fluids Operation: Softseal piston Stainless steel bellow

Materials: Housing: Aluminium diecast Sensor: Brass or Stainless steel (1.4404) Sealing: Stainless steel-bellows

Fixed switching pressure difference Symbol

92

Model

Operating pressure *1) (bar)

Over pressure *2) (bar)

Switching pressure difference (typical) Lower range Upper range (bar) (bar)

Pressure sensor material

Port size

Sensor

1840115

-1 ... 0

10

0,20

0,23

1.4404

G1/2

B

1840215

-1 ... 1

10

0,20

0,25

1.4404

G1/2

B

1840415

-1 ... 2,5

10

0,22

0,26

1.4404

G1/2

B

1841115

0,05 ... 1

10

0,16

0,18

1.4404

G1/2

B

1841215

0 ... 1,6

10

0,16

0,20

1.4404

G1/2

B

1841415

0,5 ... 4

20

0,50

0,55

1.4404

G1/2

B

1841515

0,5 ... 6

20

0,60

0,70

1.4404

G1/2

B

1841615

0,5 ... 10

20

0,70

0,90

1.4404

G1/2

B

1841715

1 ... 16

50

1,00

1,40

1.4404

G1/2

F

1841815

1 ... 25

50

1,30

1,80

1.4404

G1/2

F

1841915

5 ... 63

150

2,00

5,00

1.4404

G1/2

H

For further information www.imi-precision.com

Adjustable switching pressure difference Symbol

Model

Operating pressure *1) (bar)

Over pressure *2) (bar)

Switching pressure difference (typical) Lower range Upper range minimal maximal (bar) (bar) (bar)

Pressure sensor material

Port size

Sensor

1850115

-1 ... 0

10

0,19

0,25

0,80

1.4404

G1/2

B

1850215

-1 ... 1

10

0,20

0,30

1,00

1.4404

G1/2

B

1850415

-1 ... 2,5

10

0,20

0,28

2,50

1.4404

G1/2

B

1851115

0,05 ... 1

10

0,16

0,18

0,80

1.4404

G1/2

B

1851215

0 ... 1,6

10

0,10

0,16

1,00

1.4404

G1/2

B

1851315

0,1 ... 2,5

10

0,18

0,22

2,00

1.4404

G1/2

B

1851415

0,5 ... 4

20

0,50

0,60

2,50

1.4404

G1/2

B

1851515

0,5 ... 6

20

0,60

0,70

5,00

1.4404

G1/2

B

1851615

0,5 ... 10

20

0,70

0,90

8,00

1.4404

G1/2

B

1851715

1 ... 16

50

1,60

1,90

12,00

1.4404

G1/2

F

1851815

1 ... 25

50

1,60

2,20

20,00

1.4404

G1/2

F

1851915

5 ... 63

150

2,00

5,00

20,00

1.4404

G1/2

H

*1) Atmospheric air pressure. *2) Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure.

Accessories Brackets

Surge damper

Pressure port reducing nipple

0574772 (Steel)

0553258 (G1/4, Stainless steel 14505, AISI 303/304 S)

0553831 (G1/2 & 1/2 NPT, Stainless steel 14505, AISI 303/304 S)

0553908 (Stainless steel)

0574773 (G1/4, Brass/Steel)

0550083 (G1/4A ... G1/2A, Stainless steel 14505, AISI 303/304 S) 0574765 (G1/4 ... 1/4 NPT, Brass)


20D Hydraulic ATEX

Microswitch with gold plated contacts

Technical features

• 5 … 400 bar, G1/4

For Ex zones 1 and 2 (gases) category II2G type of protection Ex db eb IIC T6 For Ex zones 21 and 22 (dusts) category II2D type of protection Ex tb IIIC T80°C IP65

P R E S S U R E S WI T C H E S & S E N S OR S

• Electro-mechanical pressure switch

Degree of protection: IP65 (DIN 40050) Fluid/Ambient temperature: -10°C … +75°C (+14°F … 167°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Materials: Housing: Aluminium diecast, anodised Sensor: Stainless steel (1.4404) Sealing: Steel piston (NBR or FPM)

Medium: For neutral, self lubricating fluids, hydraulic oil, lube oil, light fuel oil Operation: Piston

Switching pressure range *1) (bar)

Max. Over pressure *2) (bar)

Switching pressure difference (typical) Lower range Upper range (bar) (bar)

Fluid contact parts

Sensor

Port size

1846505

5 ... 160

300

5,00

9,00

Brass, steel, NBR

Piston

G1/4

1846705

10 ... 400

550

7,00

18,00

Brass, steel, FPM

Piston

G1/4

Adjustable switching pressure difference Symbol

Model

Switching pressure range *1) (bar)

Max. Over pressure *2) (bar)

Switching pressure difference (typical)

1856505

5 ... 160

300

8,00

22,00

1856705

10 ... 400

550

15,00

40,00

Fluid contact parts

Sensor

Port size

120,00

Brass, steel, FPM

Piston

G1/4

300,00

Brass, steel, FPM

Piston

G1/4

Lower Upper range range minimal maximal (bar) (bar) (bar)

*1) Atmospheric air pressure. *2) Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure.

Accessories Brackets

Surge damper

Pressure port reducing nipple

0574772 (Steel)

0553258 (G1/4, Stainless steel 14505, AISI 303/304 S)

0553831 (G1/2 & 1/2 NPT, Stainless steel 14505, AISI 303/304 S)

0553908 (Stainless steel)

0574773 (G1/4, Brass/Steel)

0550083 (G1/4A ... G1/2A, Stainless steel 14505, AISI 303/304 S) 0574765 (G1/4 ... 1/4 NPT, Brass)

For further information www.imi-precision.com

Model

93

Fixed switching pressure difference Symbol

3


3

33D Hydraulic / Allfluid Electronic lock

P R E S S U R E S WI T C H E S & S E N S OR S

• Electronic pressure switch

Technical features

• 0 … 630 bar G1/4 or Flange

Medium: For neutral and aggressive, gaseous and liquid fluids Fluid/Ambient temperature: -10°C … +80°C/-10°C … +60°C (+14°F … +176°F/+14°F … +140°F)

94

Output signal 1 x PNP

Materials: Sensor (fluid-affected parts): Stainless steel 1.4571 (0 … 250 bar) (0 … 3625 psi), Stainless steel 1.4542 (400 … 630 bar) (5800 … 9137 psi)

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Temperature sensitivity: Zero point < ± 0,4% of final value pro 10° Kelvin - typ. Range < ± 0,2% of final value pro 10° Kelvin - typ. Display: LCD 4 digits, illuminated, pressure unit programmable bar, psi, mpa (customer specific pressure unit available on request)

Symbol

For further information www.imi-precision.com

P

Easy programming of switchpoints and extra functions

Switching status indicated by LCD

Electrical parameters Power supply: UB = 10 to 32 V DC 15 to 32 V DC (analogue) polarity safe Output signal: Digital: UB minus 1.5 V Analogue: 4 to 20 mA Contact rating: Imax = 500 mA (short-circuit proof)

Model

Switching pressure range (bar)

Over pressure* (bar)

Fluid connection

Output signal

Display step size (bar)

0863112 **

0 ... 10

40

G1/4

1 x PNP

0,050

0863116

0 ... 10

40

Flange

1 x PNP

0,050

0863312 **

0 ... 40

100

G1/4

1 x PNP

0,200

0863316

0 ... 40

100

Flange

1 x PNP

0,200

0863412 **

0 ... 100

200

G1/4

1 x PNP

0,500

0863416

0 ... 100

200

Flange

1 x PNP

0,500

0863512

0 ... 160

300

G1/4

1 x PNP

0,500

0863516

0 ... 160

300

Flange

1 x PNP

0,500

0863612 **

0 ... 250

500

G1/4

1 x PNP

1,000

0863616

0 ... 250

500

Flange

1 x PNP

1,000

0863712 **

0 ... 400

750

G1/4

1 x PNP

2,000

0863812

0 ... 630

1000

G1/4

1 x PNP

2,000

* Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure. ** Standard models.

Output signal 2 x PNP Symbol

P

Model

Switching pressure range (bar)

Over pressure* (bar)

Fluid connection

Output signal

Display step size (bar)

0863122 **

0 ... 10

40

G1/4

2 x PNP

0,050

0863126

0 ... 10

40

Flange

2 x PNP

0,050

0863322

0 ... 40

100

G1/4

2 x PNP

0,200

0863422 **

0 ... 100

200

G1/4

2 x PNP

0,500

0863426

0 ... 100

200

Flange

2 x PNP

0,500

0863522

0 ... 160

300

G1/4

2 x PNP

0,500

0863526

0 ... 160

300

Flange

2 x PNP

0,500

0863622 **

0 ... 250

500

G1/4

2 x PNP

1,000

0863722 **

0 ... 400

750

G1/4

2 x PNP

2,000

0863822

0 ... 630

1000

G1/4

2 x PNP

2,000

* Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure. ** Standard models.


33D Hydraulic / Allfluid

3

Symbol

P

Model

Switching pressure range (bar)

Over pressure* (bar)

Fluid connection

Output signal

Display step size (bar)

0863142 **

0 ... 10

40

G1/4

1 x PNP / 4 ... 20 mA

0,050

0863342

0 ... 40

100

G1/4

1 x PNP / 4 ... 20 mA

0,200

0863442 **

0 ... 100

200

G1/4

1 x PNP / 4 ... 20 mA

0,500

0863542

0 ... 160

300

G1/4

1 x PNP / 4 ... 20 mA

0,500

0863642 **

0 ... 250

500

G1/4

1 x PNP / 4 ... 20 mA

1,000

0863742

0 ... 400

750

G1/4

1 x PNP / 4 ... 20 mA

2,000

0863842

0 ... 630

1000

G1/4

1 x PNP / 4 ... 20 mA

2,000

* Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure.

** S tandard models.

Accessories Surge damper

Connector M 12 x 1 90°

0574767 (brass)

0574773 (brass)

0523058 (2 m cable, 4-core)

0550083 (Stainless steel)

0553258 (Stainless steel)

0523053 (5 m cable, 4-core)

Connector M 12 x 1 straight

0523056 (90° without cable)

0523057 (2 m cable, 4-core) 0523052 (5 m cable, 4-core)

0523055 (without cable)

95

Pressure port reducing nipple

P R E S S U R E S WI T C H E S & S E N S OR S

Output signal 1 x PNP/1 x analogue 4 ... 20 mA

0250081 (5 m cable length, 5-core, on PE-requirement*)

For further information www.imi-precision.com

* Cable with screening.


3

18S Allfluid Robust stainless steel housing

P R E S S U R E S WI T C H E S & S E N S OR S

• Electronic pressure sensor

Technical features

• 0 ... 800 bar G1/4

Medium: For neutral and aggressive gases or fluids Temperature: Fluid: -20°C ... +85°C or -40°C ... +125°C* (-4°F ... +185°F or 40°F ... +257°F)* Ambient: -20°C ... +85°C or -40°C ... +110°C* (-4°F ... +185°F or (-40°F ... +230°F)* * on request Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Degree of protection: IP65 (DIN 40050) with mounted plug

Supply voltage: 12 ... 30 V d.c. (current output) 15 ... 30 V d.c. (voltage output) Output signal: 4 to 20 mA (2-wire technology) 0 to 10 V (3-wire technology) Frequency output on request Electrical connection: M12 x 1/cable on request Temperature sensitivity: Zero point < ± 0,4% of final value pro 10° Kelvin - typ. Range < ± 0,2% of final value pro 10° Kelvin - typ. Materials: Housing: Stainless steel 1.4571/1.4542 Sensor: Stainless steel membrane 1.4542

Temperature compensated

96

18S Allfluid with M12 x 1 - Electrical connection Symbol

For further information www.imi-precision.com

P I

P U

Model

Measuring range (relative pressure) bar

Over pressure

Fluid connection

Output signal

0862170

0 ... 10

40

G1/4

4 ... 20 mA

0862370

0 ... 25

50

G1/4

4 ... 20 mA

0862470

0 ... 100

200

G1/4

4 ... 20 mA

0862670

0 ... 250

500

G1/4

4 ... 20 mA

0862770

0 ... 400

750

G1/4

4 ... 20 mA

0862970

0 ... 800

1000

G1/4

4 ... 20 mA

0862180

0 ... 10

40

G1/4

0 ... 10 Volt

0862380

0 ... 25

50

G1/4

0 ... 10 Volt

0862480

0 ... 100

200

G1/4

0 ... 10 Volt

0862680

0 ... 250

500

G1/4

0 ... 10 Volt

0862780

0 ... 400

750

G1/4

0 ... 10 Volt

0862980

0 ... 800

1000

G1/4

0 ... 10 Volt

0523057 (2 m cable, 4-core)

0523055 (without cable)

Plug not included. Alternative sensor ranges available on request.

Accessories Connector M 12 x 1 90°

0523058 (2 m cable, 4-core) 0523053 (5 m cable, 4-core) 0799845 ( 2 m cable length, 5-core, on PE-requirement*) 0250081 (5 m cable length, 5-core, on PE-requirement*) * Cable with screening.

Connector M 12 x 1 straight

0523056 (90° without cable)

0523052 (5 m cable, 4-core)

High overpressure


4 Air Preparation High efficiency water removal

Miniature high corrosion resistant design

Suitable for marine and offshore applications


4

Fast Find Guide

A I R P R E P A R A T I ON

Stainless steel - Air preparation F22

R22

Filter 1/2”

L22

Regulator 1/2”

0 … 17 bar SS

Page 99

R38

0,4 … 10 bar SS

Page 99

B38

Instrument Regulator 1/4”

0,04 … 10 bar SS

Lubricator 1/2”

0,25 … 10 bar SS

Page 99

0,5 … 15 bar SS

0 … 17 bar SS

0,3 … 9 bar SS

Page 100

B05

Filter Regulator 1/4” & 1/2”

Page 102

B38

1/2”

IFR3, IFR4

Instrument Filter Regulator 1/4”

Page 102

0 … 17 bar SS

Three Stage Filtration

0,3 … 8,6 bar SS

Page 104

W11, W12, W13

Filter - mesh element 3/8” … 1 1/2”

98

Page 105

Zinc or aluminium alloy - General purpose Air preparation For further information www.imi-precision.com

B72G, B74G

B68G

Excelon Filter Regulator 1/4" & 1/2

0,3 … 10 bar ALU, ZI

ALU

Aluminium

Olympian Filter Regulator 1”

Page 106

SS

0,4 … 8 bar ALU

Stainless Steel

Page 107

ZI

Zinc Die-casting

Page 101

Regulator 1/4”

Stainless steel - High pressure filtration

0 … 550 bar SS

Filter Regulator 1/4”,3/8”,1/2” & 1”

R05

Filter Regulator 1/4”

Page 103

B38P

Filter Regulator 1/2"

0,3 … 8,6 bar SS

Page 104

0,5 … 10 bar SS

Page 101


F22, R22, L22

Materials meet NACE

recommendations Technical features

• Filters, pressure regulators, lubricators

Medium: Compressed air only Maximum inlet pressure: 17 bar (246 psi) (F22, L22) 20 bar (290 psi) (R22) Filter element: 25 μm (F22) Gauge ports: 1/4 PTF (R22) Pressure range: R22: 0,4...10 bar (5,8 … 150 psi)

• 1/2” PTF

A I R P R E P A R A T I ON

• Stainless steel general purpose

4

Materials: Body & bowl: stainless steel (F22, L22) Filter element: PE- or sintered stainless steel (F22) Adjusting screw: stainless steel (R22) Elastomers: Synthetic rubber

Note: Outlet pressure can be adjusted in excess of and also less than those listed

Start point: (L22): 1,7 dm3/s at 6,3 bar Ambient/Media temperature: -20°C … +80°C (-4°F … +176°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Models

Accessories

Service Kit

F22 SERIES Port size

Flow* (dm3/s)

Wall mounting bracket

Auto drain

Manual drain

F22-400-A7DA

F22-400-M7DA

1/2 PTF

57

18-001-962

F22-KITA25

F22-KITM25

* Typical flow with 10 bar inlet pressure and 0,5 bar droop from a set pressure of 6,3 bar.

Models

Accessories

Service Kit

R22 SERIES Model

Port size

Flow* (dm3/s)

Wall mounting bracket

Neck mounting bracket

Gauge**

Service kit

R22-401-RNMA

1/2 PTF

50

18-001-962

18-001-959

18-013-909

R22-KITR

* Typical flow with 10 bar inlet pressure and 1 bar droop from a set pressure of 6,3 bar. ** Stainless Steel Items not strictly to NACE MR-01-75.

Models

Accessories

Service Kit

L22 SERIES Model

Port size

Flow* (dm3/s)

Wall mounting bracket

Service kit

L22-400-OP8A

1/2 PTF

48

18-001-962

L22-KIT

* Typical flow with 10 bar inlet pressure and 0,5 bar droop from a set pressure of 6,3 bar.

For further information www.imi-precision.com

MANUAL DRAIN Model

99

AUTO DRAIN Model


4

Three Stage Filtration 316 Stainless steel

A I R P R E P A R A T I ON

• Stainless Steel Three Stage Filtration

Technical features

• Particle and oil removal (coalescing) filters

Medium: Compressed air, Hydrocarbon gas* Air quality: Within ISO 8573-1, Class 1 (particulates) and Class 2 (oil content) Operating pressure: 17 bar (246 psi) max Filter elements: 1st stage: 25 µm 2nd stage: 5 µm 3rd stage: 0.01 µm Maximum remaining oil content in outlet air: 0,01 ppm at 20°C with an inlet concentration of 12 ppm. Ambient/Media temperature: -20°C … +80°C (-4°F … +176°F)

• 24-011-001 … 003, 1/2" PTF

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Materials: Body & bowl: 316 stainless steel Filter element: 316 sintered stainless steel, Acetal, synthetic fiber, EPDM, polyester Bowl sight glass: Pyrex Elastomers: NBR Manual drain: 316 Stainless steel, NBR Automatic drain: 316 Stainless steel, Nylon, Acetal, NBR Service life indicator Lens: Transparent nylon Internal parts: Acetal Spring: 18-8 Stainless steel

High efficiency

* Confirm compatibility with materials of construction. Use in gas applications must be in a well vented or outdoor area. Products are designed with an allowable leakage and should only be used within the specifications printed on the data sheet or the product label for pressure, temperature, etc. It is the responsibility of the user to apply the product in a safe environment free from potential fire or explosive materials or components. IMI Precision Engineering will not be responsible for any injury or damage caused by the use of the product in an unsafe application.

100

Technical data, standard model Symbol

For further information www.imi-precision.com

Model

Port size

Flow *1) (dm3/s)

Drain

Service life indicator

Weight (kg)

24-022-003

1/2 PTF

35,4

Manual

Visual

6,05

24-022-004

1/2 PTF

35,4

Automatic

Visual

6,29

*1) Maximum flow with at 6,3 bar inlet pressure to maintain stated oil removal performance.

Metallic parts meet NACE


B38, B38P Technical features

• Filter/regulator

Medium: Compressed air only Maximum inlet pressure: 17 bar (246 psi) (autodrain) 31 bar (449 psi) (manual drain) Flow: 100 dm3/s

• 1/4”,3/8”,1/2” & 1”

Materials: Body, bowl, bonnet, and adjusting screw: Stainless steel Filter element: PE (B38), Stainless steel (B38P) Elastomers: NBR (B38), FPM (B38P)

Typical flow with 12 bar inlet pressure, 8 bar set pressure and 1 bar droop from set

Gauge ports: 1/4” PTF Relief port: 1/8” PTF Ambient/Media temperature: -40°C … +80°C (-40°F … +176°F)

4 Metallic parts meet NACE

A I R P R E P A R A T I ON

• Stainless steel general purpose

Designed for use in corrosive enviroments

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Particle removal: 5 μm, 25 μm, 40 μm filter element

Models

Accessories

B38 SERIES - GENERAL PURPOSE Port size

Outlet Pressure range

Flow* (dm3/s)

Drain

Element

Neck mounting bracket & nut

Gauge**

B38-444-M1LA

1/2 PTF

0,3 … 9 bar

75

Manual

5 µm

18-001-973

18-013-909

B38-444-M2LA

1/2 PTF

0,3 … 9 bar

75

Manual

25 µm

18-001-973

18-013-909

B38-444-A1LA

1/2 PTF

0,3 … 9 bar

75

Automatic

5 µm

18-001-973

18-013-909

B38-444-A2LA

1/2 PTF

0,3 … 9 bar

75

Automatic

25 µm

18-001-973

18-013-909

101

Model

Models

Accessories

B38P SERIES - HIGH FLOW Model

Port size

Outlet Pressure range

Flow* (dm3/s)

Drain

Element

Neck mounting bracket & nut

Gauge**

B38P-254-B1MA

1/4 PTF

0,5 … 10 bar

40

Manual

5 µm

18-001-973

18-013-909

B38P-354-B1MA

3/8 PTF

0,5 … 10 bar

40

Manual

5 µm

18-001-973

18-013-909

B38P-454-B1MA

1/2 PTF

0,5 … 10 bar

75

Manual

5 µm

18-001-973

18-013-909

B38P-854-B1MA

1 PTF

0,5 … 10 bar

75

Manual

5 µm

18-001-973

18-013-909

B38P-254-A1MA

1/4 PTF

0,5 … 10 bar

40

Automatic

5 µm

18-001-973

18-013-909

B38P-354-A1MA

3/8 PTF

0,5 … 10 bar

40

Automatic

5 µm

18-001-973

18-013-909

B38P-454-A1MA

1/2 PTF

0,5 … 10 bar

75

Automatic

5 µm

18-001-973

18-013-909

B38P-854-A1MA

1 PTF

0,5 … 10 bar

75

Automatic

5 µm

18-001-973

18-013-909

* Typical flow with 12 bar inlet pressure and 1 bar droop from set pressure of 8 bar. ** Stainless Steel Items not strictly to NACE MR-01-75.

For further information www.imi-precision.com

* Typical flow with 12 bar inlet pressure and 1 bar droop from set pressure of 8 bar. ** Stainless Steel Items not strictly to NACE MR-01-75. Units supplied complete with panel mounting ring.


4

R38, B38

A I R P R E P A R A T I ON

• Stainless steel instrument

Technical features

• Regulators and Filter/regulators

Medium: Compressed air only Maximum inlet pressure: 17 bar (246 psi) (B38 automatic drain) 31 bar (449 psi) (R38 & B38 manual drain) Gauge ports: 1/4” PTF Pressure range: See table Note: Outlet pressure can be adjusted in excess of and also less than those listed Ambient/Media temperature: -40°C … +80°C (-40°F … +176°F)

• 1/4" PTF

Materials: Body, bowl, bonnet and adjusting screw: Stainless steel Filter element: PE (B38 only) Elastomers: Synthetic rubber

Suitable for marine and offshore applications

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Models

Accessories

R38 SERIES PRECISION PRESSURE REGULATOR Port size

Pressure range

Flow* (dm3/s)

Neck mounting bracket & nut

Gauge**

R38-240-RNCA

1/4 PTF

0,04 … 2 bar

8

18-001-973

18-013-913

R38-240-RNFA

1/4 PTF

0,07 … 4 bar

8

18-001-973

18-013-913

R38-240-RNMA

1/4 PTF

0,50 … 10 bar

8

18-001-973

18-013-909

102

Model

For further information www.imi-precision.com

* Typical flow with 7 bar inlet pressure and 0,05 bar droop from set pressure of 1 bar. ** Stainless Steel Items not strictly to NACE MR-01-75.

Models

Accessories

B38 SERIES PRECISION FILTER/REGULATOR Model

Port size

Pressure range

Flow* (dm3/s)

Drain

Filterelement

Neck mounting bracket & nut

Gauge**

B38-244-B1KA

1/4 PTF

0,25 … 7 bar

8

Manual

5 µm

18-001-973

18-013-909

B38-244-B2KA

1/4 PTF

0,25 … 7 bar

8

Manual

25 µm

18-001-973

18-013-909

B38-244-A1KA

1/4 PTF

0,25 … 7 bar

8

Automatic

5 µm

18-001-973

18-013-909

B38-244-A2KA

1/4 PTF

0,25 … 7 bar

8

Automatic

25 µm

18-001-973

18-013-909

B38-244-B1MA

1/4 PTF

0,4 … 10 bar

8

Manual

5 µm

18-001-973

18-013-909

B38-244-B2MA

1/4 PTF

0,4 … 10 bar

8

Manual

25 µm

18-001-973

18-013-909

B38-244-A1MA

1/4 PTF

0,4 … 10 bar

8

Automatic

5 µm

18-001-973

18-013-909

B38-244-A2MA

1/4 PTF

0,4 … 10 bar

8

Automatic

25 µm

18-001-973

18-013-909

* Typical flow with 7 bar inlet pressure and 0,05 bar droop from set pressure of 1 bar. ** Stainless Steel Items not strictly to NACE MR-01-75.

ATEX classification


IFR3, IFR4 Technical features

• Filter/regulator

Medium: Compressed air Maximum inlet pressure: 20 bar (290 psi) Outlet pressure range: Standard: 0,5 … 10 bar (7 … 145 psi) Ambient/Media temperature: Standard: -30°C … +90°C (-22°F … +194°F) Optional: -55°C … +90°C (-67°F … +194°F)

• 1/4" & 1/2" NPT

Materials: Valve body: 316 stainless steel Seat and spring: stainless steel O-rings, seals and diaphragm: NBR

ATEX

4 A I R P R E P A R A T I ON

• Stainless Steel General Purpose

Suitable for marine and offshore applications

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Models - No Gauge Symbol

Model

Port size

Outlet pressure *1) (bar)

Element (μm)

Flow *2) (dm3/s)

Drain

Gauge

YR2ACA1H0BS040

1/4 NPT

0,5 … 10

40

65

Manual

None

YR2ACA3H0BS040

1/2 NPT

0,5 … 10

40

160

Manual

None

103

*1) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. *2) Typical flow with 10 bar inlet pressure, 6,3 bar set pressure and a 1 bar drop from set.

Model

Port size

Flow *2) (dm3/s)

Drain Type

Element Size

Gauge Type

YR2ACA1H1BS005

1/4 NPT

65

Manual

5 µm

Dry

YR2ACA1H1BS040

1/4 NPT

65

Manual

40 µm

Dry

YR2ACA1H2BS005

1/4 NPT

65

Manual

5 µm

Glycerine filled

YR2ACA1H2BS040

1/4 NPT

65

Manual

40 µm

Glycerine filled

YR2ACA3H1BS005

1/2 NPT

160

Manual

5 µm

Dry

YR2ACA3H1BS040

1/2 NPT

160

Manual

40 µm

Dry

YR2ACA3H2BS005

1/2 NPT

160

Manual

5 µm

Glycerine filled

YR2ACA3H2BS040

1/2 NPT

160

Manual

40 µm

Glycerine filled

YR2AAA1H1BS005

1/4 NPT

65

Automatic

5 µm

Dry

YR2AAA1H1BS040

1/4 NPT

65

Automatic

40 µm

Dry

YR2AAA1H2BS005

1/4 NPT

65

Automatic

5 µm

Glycerine filled

YR2AAA1H2BS040

1/4 NPT

65

Automatic

40 µm

Glycerine filled

YR2AAA3H1BS005

1/2 NPT

160

Automatic

5 µm

Dry

YR2AAA3H1BS040

1/2 NPT

160

Automatic

40 µm

Dry

YR2AAA3H2BS005

1/2 NPT

160

Automatic

5 µm

Glycerine filled

YR2AAA3H2BS040

1/2 NPT

160

Automatic

40 µm

Glycerine filled

*2) Typical flow with 10 bar inlet pressure, 6,3 bar set pressure and a 1 bar drop from set.

For further information www.imi-precision.com

Models - inc. gauge


4

B05, R05

A I R P R E P A R A T I ON

• General purpose stainless steel

Technical features

• Regulators and filter-regulator

Medium: Compressed air only Maximum inlet pressure: 17 bar (246 psi) Filter element: 5 μm Gauge ports: 1/8” PTF Pressure range: 0,3 … 8,6 bar (4,4 … 123 psi) Ambient/Media temperature: -34°C … +66°C (-29°F … +176°F)

• 1/4” PTF

Metallic parts meet NACE Materials: Body and valve: Stainless steel 316 Bowl : Stainless steel 316 (B05 only) Bonnet: Stainless steel 316 Valve seat: Acetal Spring: Stainless steel 302 Drain: Stainless steel 316 (B05 only) Filter element: Sintered PE (B05 only) Elastomers: FPM Automatic drain: NBR (B05 only)

Miniature high corrosion resistant design

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

104

Models

Accessories

B05 SERIES

For further information www.imi-precision.com

Model

Port size

Flow* (dm3/s)

Gauge**

Mounting nut (Acetal)

B05-238-M1LA

1/4 PTF

5

18-013-844

2962-89

Model

Port size

Flow* (dm3/s)

Gauge**

Mounting nut (Acetal)

R05-232-RNLA

1/4 PTF

3

18-013-844

2962-89

Manual Drain.

R05 SERIES

* Typical flow with 10 bar inlet pressure and 1 bar droop from set pressure of 6,3 bar. ** Stainless Steel Items not strictly to NACE MR-01-75.

Suitable for marine, petro-chemical and similar applications


W11, W12, W13 Technical features

• Filter

Medium: Liquids and gases Maximum inlet pressure: W11: 550 bar (7977 psi ) W12: 420 bar (6091 psi) W13: 310 bar (4496 psi) Filtration: 25 µm standard Ambient/Media temperature: -10°C … +100°C (+14 … +212°F) standard -40°C … +150°C (-40 … +302°F) on request

• G3/8" … G1 1/2"

Materials Body: stainless steel bs en 10088 1.4401 Filter: stainless steel mesh O-Rings: NBR

Easy and quick maintenance of mesh element

Easy installation

4 A I R P R E P A R A T I ON

• High Pressure In-line filtration

Robust design

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Symbol

105

Technical data, standard models Model

Port size

Normal size (mm)

Weight (kg)

W11A9E2N25

G 3/8

10

1,0

G1

16

3,6

G 1 1/2

24

6,4

For further information www.imi-precision.com

W12A9E6N25 W13A9E8N25


4

B72G, B74G

A I R P R E P A R A T I ON

• Excelon modular system

Technical features

• Filter/regulators

Medium: Compressed air only Maximum inlet pressure: 10 bar (246 psi) Pressure range: 0,3 … 10 bar (5 … 150 psi) Filter element: 40 μm Gauge ports: Rc1/8 (B72 & B74 with ISO G thread) 1/8 PTF (B72 with PTF thread) 1/4 PTF (B74 with PTF thread) Ambient/Media temperature: -34°C … +65°C (-29°F … +149°F) (B72) -34°C … +80°C (-29°F … +176°F) (B74)

• G1/4" & G1/2", 1/4" & 1/2" PTF

Material: Body: Zinc die-casting (B72) Bonnet: Acetal (B72) Body & bonnet: Aluminium die-casting (B74) Valve: Brass/PE Metal bowl: zinc die-casting (B72) Metal bowl: Aluminium die-casting (B74) Liquid level indicator lens (Metal bowl): Transparent PA (Pyrex optional) Element: Sintered polypropylene Elastomers: CR and NBR

in-line installation or modular installation

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

106

Models

Accessories

B72G SERIES

For further information www.imi-precision.com

AUTO DRAIN Model

MANUAL DRAIN Model

Port size

Flow* (dm3/s)

Wall mounting bracket

Neck mounting bracket

Gauge 0 … 10 bar

Tamper resistant kit

B72G-2GK-AE3-RMN

B72G-2GK-QD3-RMN

G1/4

38

4224-50

74316-50

18-013-989

4255-51

B72G-2AK-AE3-RMN

B72G-2AK-QD3-RMN

1/4 PTF

38

4224-50

74316-50

18-013-212

4255-51

Models

Accessories

B74G SERIES AUTO DRAIN Model

MANUAL DRAIN Model

Port size

Flow* (dm3/s)

Wall mounting bracket

Neck mounting bracket

Gauge 0 … 10 bar

Tamper resistant kit

B74G-4GK-AD3-RMN

B74G-4GK-QD3-RMN

G1/2

100

4324-50

4368-51

18-013-013

4355-51

B74G-4AK-AD3-RMN

B74G-4AK-QD3-RMN

1/2 PTF

100

4324-50

4368-51

18-013-209

4355-51

High efficiency water removal


B68G High efficiency water removal Technical features

• Filter/regulators

Medium: Compressed air only Maximum inlet pressure: 17 bar (246 psi) Filterelement: 40 μm Gauge ports: ISO G ports have Rc1/8 gauge port PTF ports have 1/8 PTF gauge ports Ambient/Media temperature: -20°C … +80°C (-4°F … +176°F)

• G1" & 1" PTF

A I R P R E P A R A T I ON

• Olympian Plus plug-in system

4

Materials: Body, bonnet, bowl & yoke: Aluminium die-casting Adjusting knob: Acetal resin Elastomers: Synthetic rubber Filter element: Sintered plastic

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Pressure range: 0,4...8 bar (6...120 psi) Note: Outlet pressure can be adjusted in excess of and also less than those listed

Accessories

107

Models B68G SERIES Manual drain Model

Port size

Flow* (dm3/s)

Wall mounting bracket

Gauge 0 … 10 bar

Tamper resistant kit

B68G-8GK-AR3-RLN

B68G-8GK-MR3-RLN

G1

240

18-001-979

18-013-013

4355-51

B68G-8AK-AR3-RLN

B68G-8AK-MR3-RLN

1" PTF

240

18-001-979

18-013-204

4355-51

* Typical flow with 10 bar inlet pressure and 1 bar droop from set pressure of 6,3 bar. For replacement filter/regulator (without yoke) substitute “N” at the 5th and 6th digits eg. B68G-NNK-AR3-RLN.

For further information www.imi-precision.com

Auto drain Model


4

A I R P R E P A R A T I ON

108


5 Ancillary Products

For outdoor use

Stainless steel

Reduced noise levels


5

Fast Find Guide

A N C I L L A R Y P R OD U C T S

Quick exhaust valves QEV

1/4” … 1”

0,5 … 12 bar SS

Page 111

Exhaust filters 0613422, 0613423 1/4” & 1/2”

0 … 10 bar POM

Page 112

Silencers MB Series

0014, 0613 Series

110

1/8" … 1"

-1 … 20 bar AL

T40

1/4", 1/2"

Page 113

0 … 25 bar SS

M/S

M5 … 1”

Page 114

M5 … 1”

0 … 10 bar BR

Page 115

-1 … 10 bar PE

Page 116

For further information www.imi-precision.com AL

Aluminium

BR

Brass

SS

Stainless Steel

PE

Polyethylene

POM

Plastic Polymer


QEV • Quick exhaust valves

Technical features

• 1/4 … 1 NPT

Medium: Compressed air and other neutral gases Operating pressure: 0,5 … 12 bar (7 … 174 psi) Leak Performance: Bubble tight Fluid/Ambient temperature: -50°C … +80˚C (-58 ... +176°F)

Materials: Valve body & trim: 316L stainless steel O-Rings seats & seals: NBR

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Symbol

2 3

*1) Measured in USgpm for 1 psi ∆p.

Model

Port size

Flow factor Cv *1)

Kv *2)

QEV13AA1H00S

1/4 NPT

1,6/2,1

23,2/30,5

QEV13AA3H00S

1/2 NPT

6,4/5,5

92,8/79,8

QEV13AA5H00S

3/4 NPT

10,4/10,8

149

QEV13AA6H00S

1 NPT

10,4/15,4

149

*2) Measured in l/min for 1 bar (15 psi) ∆p.

For further information www.imi-precision.com

1

111

Technical data, standard models

5 A N C I L L A R Y P R OD U C T S

Stainless steel


5

0613422, 0613423

A N C I L L A R Y P R OD U C T S

• Exhaust guard

Technical features

• 1/4” & 1/2”

Medium: Lubricated or non-lubricated compressed air, inert gases Operation: The non-return function protects the spring chamber of pneumatic actuators in particular against aggressive ambient air Operating pressure: 10 bar max. (145 psi) Operating temperature: -55°C … +80°C (-67 … +176°F)

Materials: Housing: POM ‘O’-rings: VMQ

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

112

Models Symbol

Model

Thread

Suitable for

0613422

1/4”

G1/4, 1/4 NPT

0613423

1/2”

G1/2, 1/2 NPT

universal thread BSP/NPT

Protects against contamination and moisture penetration

For further information www.imi-precision.com


MB Series Technical features

• R1/8"...R1", 1/8"PTF...1"PTF

Medium: Compressed air, filtered, lubricated and non-lubricated, inert gases Operating pressure: -1 … 20 bar (-14 ... 290 psi) Ambient temperature: -20°C … +80°C (-4 … +176°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Symbol

Corrosion resistant

113

Models

Materials: Aluminium body and shell, brass mesh element

A N C I L L A R Y P R OD U C T S

Reduce the noise levels

• Quietaire heavy duty silencers

5

Male Thread Port Size

MB001B

R1/8

MB002B

R1/4

MB003B

R3/8

MB004B

R1/2

MB006B

R3/4

MB008B

R1

Male Thread Model PTF

Port Size

MB001A

1/8 PTF

MB002A

1/4 PTF

MB003A

3/8 PTF

MB004A

1/2 PTF

MB006A

3/4 PTF

MB008A

1 PTF

For further information www.imi-precision.com

Model BSPT


5

0014, 0613 Series

A N C I L L A R Y P R OD U C T S

• Stainless steel silencers

Technical features

• G1/4 & G1/2, 1/4 NPT & 1/2 NPT

Medium: Compressed air, filtered and non-lubricated Operating pressure: 25 bar max. (362 psi) Fluid/Ambient temperature: -25°C … +100°C (-13 … +212°F)

Prevent the ingress of dirt Materials: Filter element: stainless steel Body: stainless steel

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

114

Technical data Symbol

For further information www.imi-precision.com

Model

Port size

Flow kv l/min

Continuous sound pressure level *1) 0,7 bar 6 bar

0014613

G1/4

12

63

78

0613678

1/4 NPT

12

63

78

0014813

G1/2

45

58

76

0613679

1/2 NPT

45

58

76

*1) Measured in dBA/1 meter in front and side from unit.


T40 Technical features

• M5, G1/8 … G1

Medium: Compressed air, filtered, lubricated or non lubricated, inert gases Operating pressure: 10 bar (145 psi) maximum Operating temperature: -40°C … +80°C (-40 … +176°F)

Shock and vibration resistant

Materials: Element: sintered bronze Body: brass

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Symbol

Model with ISO G-threads BSPP

Model with ISO R-threads BSPT

Port size

Flow factor Cv

Kv *1)

Continuous sound pressure level *2) 0,7 bar 6 bar

T40M0500

M5

0,2

0,21

56

70

T40C1800

T40B1800

G1/8

0,54

0,53

66

75

T40C2800

T40B2800

G1/4

1,6

1,34

68

78

T40C3800

T40B3800

G3/8

3,5

2,98

75

84

T40C4800

T40B4800

G1/2

5,1

4,47

75

88

T40C6800

T40B6800

G3/4

9

7,88

87

96

T40C8800

T40B8800

G1

11,6

10,22

93

100

For further information www.imi-precision.com

*1) Measured in m3/h. *2) SPL in dBA at 1 m from unit.

115

Technical data, Standard models

5 A N C I L L A R Y P R OD U C T S

• Sintered bronze silencers

Reduce the noise levels


5

M/S

A N C I L L A R Y P R OD U C T S

• Porous plastic silencers

Technical features

• M5, G1/8 … G1

Medium: Compressed air, filtered 50 µm, lubricated and non lubricated/vacuum, inert gases Operating pressure: -1 … +10 bar maximum (-14 … 145 psi) (vacuum service) Fluid/Ambient temperature: -20°C … +80°C (-4 … +176°F)

Reduce the noise levels

Materials: Body: UHMW polyethylene porous plastic Connector base: polyethylene

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

116

Technical data, standard models Symbol

Model

Port size

Mean flow factor C *1 Cv

Kv *2

Sound pressure level *3)

For further information www.imi-precision.com

M/S0

M5

1,27

0,31

0,27

83

M/S1

G1/8

4,1

1

0,87

84

M/S2

G1/4

7,5

1,84

1,6

84

M/S3

G3/8

16,2

4

3,45

81

M/S4

G1/2

21,8

5,3

4,64

82

M/S6

G3/4

32,8

8

7

98

M/S8

G1

49,8

12,2

10,6

94

*1) Measured in dm3/ (s.bar). *2) Measured in m3/h. *3) Measured in dBA/6bar/1 meter from unit.

Prevent the ingress of dirt


6 Additional Products


6

ACTUATORS

A DDI T I ON A L P R OD U C T S

Integrated Valve and Actuator Control (IVAC)

Impact (‘Rapping’) Cylinder

> Complete actuator and valve package in one unit

> Used in waste incineration plants for efficient cleaning

> Simplified specification and design, ordering, installation and maintenance

> Adjustable impact level reduces wear, lowering maintenance costs

> 1 Air and 1 electrical connection

> Range of accessories includind mountings and force compensators

> Cleanline corrosion resistant body

> Full control package available in standard or customised designs

> Number of solenoid options including ATEX certification

Glandless spool valve Cleanline Design

118

For further information www.imi-precision.com

ATEX Zone 2

Cleaning of heating surfaces

Horizontal boiler with installed impact system

Approved


CONTROL SYSTEMS

A DDI T I ON A L P R OD U C T S

Control Panel Solutions

6

Custom designed solutions for all kinds of applications - simple to complex. > Complete solutions, ready to install > Designed using 2D+3D CAD software > Can be pneumatic, electro-pneumatic, and also include ancillary products > Assembled and texted prior to delivery

119

Customized solutiions

For further information www.imi-precision.com


6

A DDI T I ON A L P R OD U C T S

120


Index


Index SERIES

PAGES

122

For further information www.imi-precision.com

SERIES

PAGES

VALVES

15

R22 Pressure regulator

99

97100 Inline

24

L22 Lubricator

99

97105 Inline

25

Three Stage Filtration

100

97105 NAMUR

26

B38, B38P Filter / Regulator

101

97300 NAMUR

29

R38, B38 Regulators and Filter / Regulators

102

26360 & 80207 Inline

30

IFR3, IFR4 Filter / Regulator

103

26360 & 80207 NAMUR

31

B05, R05 Filter Regulator & Regulator

104

98025 NAMUR & Inline

33

W11, W12, W13 Filter

105

6215M NAMUR & Inline

35

B72G, B74G Filter/Regulator

106

6215L NAMUR & Inline

37

B68G Filter/regulator

107

24011 NAMUR & Inline

39

ANCILLARY PRODUCTS

109

24010 NAMUR & Inline

43

QEV Quick exhaust valves

111

98015 NAMUR & Inline

44

0613422, 0613423 Exhaust guard

112

21000 Inline

46

MB Quietaire heavy duty silencers

113

23200 Inline

47

0014, 0613 Stainless steel silencers

114

24000 Inline

48

T40 Sintered bronze silencers

115

95000 Inline

50

M/S Porous plastic silencers

116

96000 Inline

51

6316 Inline

56

YX1 ICO3S EX ia Inline

57

YO1 ICO3S Inline

58

Y1 ICO4S Inline

59

82400 and 82730

64

82470

66

82540 & 82590

67

82960, 82970 diaphragm

68

82900, 82910 diaphragm

69

85500, 85540 piston

70

85780 piston

71

84500 & 84520

72

V81, V82, V83 & V84 RVM system

73

80400 pneumatically actuated

77

I/P & E/P CONVERTERS

79

140 Failsafe

81

422 Fail Freeze

82

422 IS Fail Freeze

83

VP10

84

100X

85

220

86

PRESSURE SWITCHES & SENSORS

87

18D ATEX

89

18D Hydraulic ATEX

91

20D Allfluid ATEX

92

20D Hydraulic ATEX

93

33D Hydraulic / Allfluid

94

18S Allfluid

96

AIR PREPARATION

97

F22 Filter

99


Solenoid index PAGES

4231

54

0242

32

4260

41

0245

32

4261

41

0246

52

4270

40, 44

0700

54

4271

40, 44

0763

27, 33

4280

55

0800

40, 44, 55

4281

55

0827

41

4600

27, 33, 38

1300

49

4601

27, 33, 38

1301

49

4602

27, 38

1440

49

4603

27, 38

1441

49

4610

32, 36, 52

1500

49

4611

32, 36, 52

1501

49

4612

32, 36, 52

1570

49

4613

32, 36, 52

1571

49

4620

53

1600

49

4621

53

1601

49

4622

53

2003

43

4623

53

2050

28

4630

54

2051

28

4631

54

2052

28

4632

54

2053

28

4633

54

3034

24

4660

41

3036

29

4661

41

3039

24

4662

41

3050

24, 29

4663

41

3062

24, 29

4670

40, 44

3063

24, 29

4671

40, 44

3204

53

4672

40, 44

3206

52

4673

40, 44

3703

54

4680

55

3720

38

4681

55

3722

36

4682

55

3723

36

4683

55

3803

40, 44, 55

4802

27

3805

41

4803

27

3824

41

4872

40, 44

3825

41

4873

40, 44

3826

40

6316****.6001

56

3827

40

4200

27, 33, 38

4201

27, 33, 38

4210

32, 36, 52

4211

32, 36, 52

4220

53

4221

53

4230

54

For further information www.imi-precision.com

SERIES

53

SERIES

123

PAGES

0200


Notes

124

For further information www.imi-precision.com



For further information, scan this QR code or visit www.imi-precision.com

1 2 3 4 5 6

VALVES IMI HERION VALVES - INTERCHANGEABLE COILS IMI MAXSEAL VALVES - INTEGRATED SOLENOIDS IMI BUSCHJOST DIAPHRAGM VALVES IMI BUSCHJOST PISTON VALVES IMI BUSCHJOST ANGLE SEAT PILOT VALVES REDUNDANT VALVE MANIFOLD SYSTEM IMI HERION BOOSTERS

I/P & E/P CONVERTERS 140 SERIES 422 SERIES 422 IS SERIES VP10 RANGE 100X SERIES 220 SERIES

PRESSURE SWITCHES & SENSORS 18D ATEX & 18D HYDRAULIC RANGE 18D REMAINING HYDRAULIC RANGE PLUS ACCESSORIES 20D ALLFLUID & HYDRAULCI RANGE PLUS ACCESSORIES 33D HYD/ALLFLUID RANGE PLUS ACCESSORIES 18S ALLFLUID RANGE PLUS ACCESSORIES

AIR AND GAS PREPARATION F22, R22 & L22 RANGES PLUS ACCESSORIES 22 SERIES 3 STAGE FILTRATION B38, B38P & B38 AND R38 INSTRUMENT RANGES PLUS ACCESSORIES IFR3, 4 FILTER REGULATOR RANGES B05 FILTER/REG, R05 REG AND W11 FILTER B72, B74, B64 & B68 RANGES PLUS ACCESSORIES

ANCILLARY PRODUCTS QEV RANGE 0613422/3 EXHAUST GUARD & MB QUIETAIRE SERIES SILENCERS 0014, 0613, T40 & M/S RANGE SILENCERS

ADDITIONAL PRODUCTS INTEGRATED VALVE AND ACTUATOR CONTROL (IVAC) IMPACT (‘RAPPING’) CYLINDER REDUNDANT VALVE MANIFOLD (RVM) SYSTEM CONTROL PANEL SOLUTIONS

Norgren, Buschjost, FAS, Herion and Maxseal are registered trademarks of IMI Precision Engineering companies. Due to our policy of continuous development, IMI Precision Engineering reserve the right to change specifications without prior notice. z8409CT en/10/17 Selected Images used under license from Shutterstock.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.