Energy
Process Catalogue Oil, Gas & Chemical Solutions
Engineering GREAT Solutions
Contents
1 2
5 6
PRESSURE SWITCHES & SENSORS
AIR PREPARATION (FRL)
ANCILLARY PRODUCTS
ADDITIONAL PRODUCTS
80 81 82 83 84 85 86
FAST FIND GUIDE 140 SERIES 422 SERIES 422 IS SERIES VP10 RANGE 100X SERIES 220 SERIES
88 89 92 94 96
FAST FIND GUIDE 18D ATEX & HYDRAULIC RANGE 20D ALLFLUID & HYDRAULCI RANGE 33D HYD/ALLFLUID RANGE 18S ALLFLUID RANGE
98 99 100 101 103 104 105 106
FAST FIND GUIDE F22, R22 & L22 STAINLESS STEEL AIR PREPARATION RANGE 3 STAGE FILTRATION SYSTEM B38, B38P & B38 AND R38 INSTRUMENT RANGES IFR3, IFR4 STAINLESS STEEL FILTER REGULATOR RANGE B05, R05 GENERAL PURPOSE STAINLESS STEEL RANGE W11, W12, W13 IN-LINE FILTRATION RANGE B72, B74, B68 RANGES STANDARD FILTER REGULATORS
110 FAST FIND GUIDE 111 QEV QUICK EXHAUST VALVES 112 0613422/3 EXHAUST GUARD 113 MB HEAVY DUTY SILENCERS 114 0014, 0613, T40 & M/S SILENCERS
118 INTEGRATED VALVE AND ACTUATOR CONTROL (IVAC) 118 IMPACT (‘RAPPING’) CYLINDER 119 CONTROL PANEL SOLUTIONS
All of our products are backed with an industry leading 2-year warranty. Our dedicated team of experts is on hand with technical advice, support and recommendations to help you get the most effective products, in the shortest timescales, and with the best possible service.
For further information www.imi-precision.com
4
I/P & E/P CONVERTERS
PRODUCT SELECTOR FAST FIND GUIDE IMI HERION VALVES - INTERCHANGEABLE COILS IMI MAXSEAL VALVES - INTEGRATED SOLENOIDS IMI BUSCHJOST DIAPHRAGM VALVES IMI BUSCHJOST PISTON SEAT VALVES IMI BUSCHJOST ANGLE SEAT PILOT VALVES REDUNDANT VALVE MANIFOLD SYSTEM IMI HERION BOOSTERS
1
3
VALVES
16 22 24 57 64 70 72 73 77
2
Engineering GREAT solutions For further information www.imi-precision.com
We deliver GREAT solutions for our customers tackling the world’s most demanding engineering challenges
IMI Precision Engineering is a world leader in motion and fluid control technologies. Wherever precision, speed and engineering reliability are essential, we deliver exceptional solutions which improve the productivity and efficiency of our customers’ equipment. Part of IMI plc, we have a sales and service network in 75 countries, as well as manufacturing capability in the USA, Germany, China, UK, Switzerland, Czech Republic, Mexico and Brazil. We support this with our global centres of technical excellence, and facilities for CFD design and R&D testing. We employ a dedicated team of field engineers, sector specialists and key account managers – all committed to providing excellent service to our customers.
As a business, we aim to UNDERSTAND our customers’ challenges. We then CONNECT our products, people and expertise in order to DELIVER exceptional service and solutions. These IMPROVE the performance of our customers’ machinery. We call this Engineering GREAT, and we deliver it to customers through a world-class portfolio of high performance products, through close partnerships and problem-solving, and through a global network of support which ensures reliable local delivery, all over the world.
We have a global team of key account managers and over 400 highly experienced engineers – many with in‑depth expertise of key industry sectors. We recruit and develop the industry’s top talent, offering the best training and exposure to world-class products and technologies with some of the world’s leading businesses. The deep and combined experience this gives us means we have the skills, confidence and knowhow to get closer to our customers, enabling us to understand their exact challenges and resolve them precisely. Because of this our problem‑solving is more effective, our solutions more targeted, our partnerships more productive.
High performance products
Reliability
Our world-class products improve performance and productivity.
We deliver and support our high quality products through our global service network.
We have global manufacturing capability and technical centres of excellence, each dedicated to developing and rigorously testing new high performance products to meet precise industry and application needs. Helping improve performance and reduce downtime and energy consumption on production lines across the world, our world-class portfolio includes IMI Norgren, IMI Buschjost, IMI FAS, IMI Herion and IMI Maxseal. Having proven their value over years, they stand amongst the most trusted names in fluid and motion control. We are continuously adding to this portfolio through a programme of innovation and new product development. Because of this, we’re able help our customers solve the world’s greatest engineering challenges – reliably, safely and efficiently.
We have world-class manufacturing and sales and service operations in 75 countries, supported by investment in robust project management systems and lean localised production. Together, with our integrated supply chain, and the speed of our Express service we have the systems, processes and support to deliver quality products and aftersales service precisely, reliably, in full and on time, anywhere.
For further information www.imi-precision.com
Partnerships & problem solving
3
How we deliver value to our customers
We get closer to our customers to understand their exact challenges
Our market leading product brands The combination of our IMI Precision Engineering product brands’ trusted reputation and long history underpins our position as a leading global supplier of motion and fluid control technologies. IMI Precision Engineering has a long experience and reputation in providing oil, gas and chemical solutions. > Proven in safety > Proven in reliability > Proven in durability against the harshest weather conditions and environments > Proven in knowledge
4
For further information www.imi-precision.com
With over 80 years industry experience, the IMI Norgren brand includes a wide range of high quality pneumatic and fluid control products such as actuators, air preparation products, pressure switches, fittings and valves.
Successful in the market for over 80 years, IMI Buschjost is a market leading range of process and multimedia solenoid valve technology and system solutions.
For over 50 years the IMI Herion brand has specialised in solenoid valves, NAMUR valves and hydraulic solutions for mechanical and pneumatic press and press safety technology.
Proven in the field for over 50 years, the IMI Maxseal brand offers extremely high quality stainless steel solenoid valves, for harsh environments such as offshore oil & gas and coastal applications.
New online services To improve your experience, we have introduced a range of web services, including a dedicated and intuitive competitor conversion tool, a new mobile website, and we have also introduced a new product configurator with improved CAD capabilities. We’re engineering GREAT access to our products and services to help you save time and work more efficiently.
Part Converter Looking for an IMI Precision Engineering alternative to competitor parts? Fully Compatible
Try our new Part Converter. All you need is a full or partial part number to find the IMI Precision Engineering alternative. It tells you everything you need to know, including technical details and whether it’s an exact or partial match. To make things even easier, you can link straight through to the recommended alternative, review the technical detail and buy it there and then.
Configuration and CAD
Mobile
For further information www.imi-precision.com
Complete with images and technical information, our new mobile website gives you all the product details you will need to purchase, even out on the factory floor.
5
Our new mobile website lets you purchase products straight from your mobile phone or tablet, wherever you are!
Quickly and easily configure pneumatic cylinders, including the addition of mountings and accessories. It provides price and availability throughout the configuration process and the option to download a CAD file or purchase the completed configuration.
Our global reach With established manufacturing facilities globally, we have the capability to cope with the most demanding of international projects. With a sales and service network in 75 countries, we have the reach and capability to ensure continuity of supply and local support where it is needed.
North America
UK Fradley, Bristol, Leeds & Poole
6
USA Seattle
For further information www.imi-precision.com
USA Littleton
GERMANY Alpen
MEXICO QuerĂŠtaro
South America BRAZIL Sao Paulo
Europe
CZECH REPUBLIC Brno
Africa
INDIA Noida
Australia
Sales & Service in 75 countries IMI Precision Engineering sales, manufacturing and technical centres IMI Precision Engineering sales locations IMI Precision Engineering manufacturing locations
For further information www.imi-precision.com
CHINA Shanghai
7
Asia
8
For further information www.imi-precision.com
Setting the standard for safety, reliability and performance IMI Precision Engineering products are designed to work effectively in aggressive environments and extreme temperatures and meet international standards such as:
Approved
> ATEX
> KOSHA
> TĂœV
> DVGW
> TR-CU
> FM AND UL
> INMETRO
> NEMA
> CSA
> ITRI
> CCOE
DIN EN 61508 IEC 61508
9
Plants supplying products to the energy industries apply Quality Management Systems (QS 9000, VDA 6.1, ISO/TS 16949, ISO 9001, OHSAS 18001) as well as Environmental Management Systems to ISO 14001.
IMI Precision Engineering has a wide portfolio of products, specially designed for the demanding conditions and applications that the oil and gas, chemical, nuclear and power sectors require: >> Aggressive environments a wide range of products rated IP66 and above, in highly resistant materials that offer durability to off-shore salt spray. >> Extreme temperatures Meeting the harshest temperature needs, from -60°C to +200°C.
For further information www.imi-precision.com
Our work with leading national and international oil and gas companies and global suppliers in the Energy Sector means that we talk our customers’ language, and can bring specialised experience about legislation, standards and specifications.
ATEX Solutions Your Reliable Partner for Maximum Explosion Protection 10
For further information www.imi-precision.com
In addition to Directive 2014/34/ EU, which is concerned with the requirements of equipment and protective systems another directive – 1999/92/EC exists. This is concerned with the requirements for the erection, installation and operation of systems.
In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonised in 1975 with the European Frame Directive 76/117/ EEC. The EC-Directive 94/9/EG was valid from 1994 until 2016 and was replaced through the new EU-Directive 2014/34/ EU. This Directive is widely known as
“ATEX” – which derives from the original working title “ATmosphère EXplosible”.
How can explosions occur?
Typical sources of Ignition
>> Adiabatic Compression
>> Hot Surfaces
>> Electro-Magnetic Radiation
>> Flames and Hot Gases
>> Ionising Radiation
>> Mechanically Generated Sparks
>> Chemical Reactions
>> Electrically Generated Sparks
>> Ultra-sound
>> Electro-statically Generated Sparks
>> Flashes
Explosive atmospheres (Ex areas) are prerequisite for an explosion and can be found where a mixture of air, flammable gases, vapours or dusts are being produced, transformed or stored in the presence of oxygen.
ATEX Directive 94/9/EC expands earlier guidelines by including non-electric components such as pneumatic actuators. These now have to be certified.
How can an explosion be prevented? Most important is the prevention of the formation of an explosive atmosphere. If this is not possible, potential sources of ignition must be avoided. Ignition protection categories For electrical equipment for use with gases, vapours and mists special design methods are described in comprehensive works standards and are assigned to
“ignition protection categories”. Several ignition protection categories can be combined in one unit. The methods of protection with explosive dusts concentrates mainly on the sealing of the housing (IP protection). Principles and requirements for nonelectrical equipment for use in explosive areas are described in the new EN 13463-1.
Measures that can be taken to reliably exclude potential sources of ignition, depend upon the equipment category required. In the foreground is usually the consideration of the permissible light metal alloys, electrostatic charge, possible sparks caused by impact or friction and heat due to friction.
Which certificates are required?
These Declarations of Conformity are also obligatory for non-electrical equipment. However, if the risk analysis of explosion hazards show that no potential sources
of ignition exist, the item does not fall under the ATEX directive in which case a Declaration of Conformity and Ex marking is not required. This may apply to products used in purely pneumatic systems, i.e. for valves, service units, sound absorbers.
Figure 1 EU Declaration of Conformity for valve solenoids Figure 2 EC-Type examination certificate for a solenoid valve series Figure 3 Certificate for the Quality Assurance System
Figure 1
Figure 2
Figure 3
Prevent explosions with IMI Precision Engineering ATEX approved equipment As a manufacturer of pneumatic equipment, IMI Precision Engineering offers an extensive range of certified devices in Categories 1, 2 and 3 for use in areas with potentially explosive atmospheres containing gases and dusts:
>> Solenoid valves, solenoids (Type of protection Ex m, Ex me, Ex md,Ex d, Ex ia, Ex nA) >> Pressure switches (Type of protection Ex de, Ex nAC)
>> Valves, cylinders, (Type of protection Ex c)
For further information www.imi-precision.com
For electrical equipment in Category 1 and 2, an EU Type Examination Certificate
issued by a notified body is required. For non electrical equipment an EU Type Examination Certificate is only required for Category 1.
11
A Declaration of Conformity must be provided by the manufacturer for each product. The Declaration of Conformity explains how the manufacturer fulfils all the relevant safety requirements. The CE mark is subsequently attached to the product.
Marking of solenoid valves in potentially explosive atmospheres CONDITIONS IN HAZARDOUS AREAS
FLAMMABLE SUBSTANCES
gases, vapours
dusts
TEMPORARY BEHAVIOUR OF FLAMMABLE SUBSTANCES IN HAZARDOUS PLACES
SUBDIVISION OF HAZARDOUS PLACES
is present continuously or for long periods or frequently
REQUIRED MARKING FOR INSTALLATION CLASSIFICATION OF HAZARDOUS AREAS
EQUIPMENT CATEGORY
EQUIPMENT PROTECTION LEVEL (EPL)
zone 0
II
1G
Ga
is likely to occur in normal operation occasionally
zone 1
II
2G or 1G
Gb or Ga
is not likely to occur in normal operation but, if it does occur, will persist for a short period only
zone 2
II
3G or 2G or 1G
Gc or Gb or GA
is present continuously or for long periods or frequently
zone 20
II
1D
Da
is likely to occur in normal operation occasionally
zone 21
II
2D or 1D
Db or Da
is not likely to occur in normal operation but, if it does occur, will persist for a short period only
zone 22
II
3D or 2D or 1D
Dc or Db or Da
12
5 0123 x II 2G Ex ia IIC T6 Gb PTB 07 ATEX 2019 X
For further information www.imi-precision.com
TYPE OF PROTECTION
PRINCIPLE OF PROTECTION
APPLICATION
MARKING
MAY BE USED IN ZONE
IEC
CENELEC
general requirements
–
all applications
–
–
IEC 60079-0
EN 60079-0
flameproof enclosure
a propagation of an explosion inside to the outside is excluded
control stations, motors, fuses, switchgear, power electronics
Ex d
1 or 2
IEC 60079-1
EN 60079-1
increased safety
avoidance of arcs, sparks and excessive temperature
installation materials, motors, luminaries
Ex e
1 or 2
IEC 60079-7
EN 60079-7
limitation of energy and through that prevention of ignitable sparks
measurement and control, automation technology, sensors, actuators
Ex ia
0, 1 or 2
IEC 60079-11
EN 60079-11
intrinsic safety
Ex ib
1 or 2
IEC 60079-11
EN 60079-11
pressurisation
ex-atmosphere can‘t enter through the overpressure
switch- and control cupboards, analyse-apparatus, computers
Ex p
1 or 2
IEC 60079-2
EN 60079-2
encapsulation
ex-atmosphere can‘t enter through the potting material
coils of motors or relays, solenoid valves
1 or 2
IEC 60079-18
EN 60079-18
oil immersion
ex-atmosphere can‘t enter through the oil
transformers, relays, control stations, magnetic contactors
Ex o
1 or 2
IEC 60079-6
EN 60079-6
powder filling
an propagation of an ignition inside to the outside is excluded
capacitors, transformers
Ex q
1 or 2
IEC 60079-5
EN 60079-5
non sparking
avoidance of ignitable sparks in normal operation
sensors, solenoids, pressure switches
Ex n
2
IEC 60079-15
EN 60079-15
Ex ma Ex mb
EXPLOSION GROUP
TEMPERATURE CLASS (GASES)
MARKING
EXAMPLE
PERMISSIBLE EQUIPMENT GROUP
IIA
propane
IIA or IIB or IIC
IIB
ethylene
IIB or IIC
IIC
hydrogen
IIC
TEMPERATURE CLASS (GASES)
MAX. SURFACE TEMPERATURE OF THE EQUIPMENT
PERMISSIBLE TEMPERATURE CLASSES OF THE EQUIPMENT
EXAMPLE
T1
450°C
T1 to T6
town gas
T2
300°C
T2 to T6
ethylene
T3
200°C
T3 to T6
gasoline fuels
T4
135°C
T4 to T6
acetaldehyde
T5
100°C
T5 to T6
T6
85°C
T6
carbon disulfide
5 0123 x II 2G Ex ia IIC T6 Gb TUV PTB 07 ATEX 2019 X NOTIFIED BODY FOR THE EQUIPMENT APPROVAL
CODE NUMBER
COUNTRY
TÜV
0044
Germany
REQUIREMENTS
MARKING
INERIS
0080
France
without restriction
–
Physikalisch Technische Bundesanstalt
PTB
0102
Germany
special condition should be noted
X
TÜV SÜD Product Service GmbH
TPS
0123
Germany
DEKRA EXAM GmbH
BVS
0158
Germany
DEKRA/KEMA
0344
Netherlands
SIRA
0518
UK
BASEEFA
1180
UK
TÜV NORD CERT GmbH INSTITU NATIONAL DE L´ENVIRONNEMENT INDUSTRIEL ET DES RISQUES
SIRA CERTIFICATION SERVICE SGS BASEEFA LIMITED
Ex-component, which is not intended to be used alone and requires additional certification. U
CE-Conformity is declared by the manufacturer if the part is fitted into a complete equipment.
In dust atmospheres
II 2D Ex tb IIIC T 90°C Db TYPE OF PROTECTION
MARKING
MAY BE USED IN ZONE
STANDARD
Flameproof enclosures
Ex d
1 or 2
IEC EN 60079-1
Increased safety
Ex e
1 or 2
IEC EN 60079-7
Ex ia
0 or 1 or 2or 20 or 21 or 22
Ex ib
1 or 2 or 21 or 22
Ex ic
2 or 22
Ex ma
0 or 1 or 2or 20 or 21 or 22
Ex mb
1 or 2 or 21 or 22
Ex mc
2 or 22
Ex n
2 or 22
Ex ta
20 or 21 or 22
Ex tb
21 or 22
Ex tc
22
Intrinsic safety
Encapsulation
„n“ type of protection
Protection by enclosure
IEC EN 60079-11
Max. surface temperature of the equipment
EXPLOSION GROUP (DUSTS) MARKING
Type of Dust
Example
Permissible equipment group
IIIA
Combustible flyings
Cotton
IIIA or IIIB or IIIC
IIIB
Non-conductive dust
Grain
IIB or IIIC
IIIC
Conductive dust
Aluminium dust
IIIC
IEC EN 60079-18
IEC EN 60079-15
IEC EN 60079-31
For further information www.imi-precision.com
DEKRA Certification B.V.
RESTRICTION FOR USING APPARATUS
13
SHORT NAME
14
1 Valves
NAMURInterface
Suited for outdoor applications
Universal flow direction
Flange version
13 mm
6215M NAMUR & Inline G1/4,1/4 NPT 2.5 … 8 bar
13 mm
6215M NAMUR & Inline G1/4,1/4 NPT 2.5 … 8 bar
16 mm
24011 NAMUR & Inline G1/4, 1/4 NPT 0 … 10 bar
16 mm
24010 NAMUR & Inline G1/4, 1/4 NPT 0 … 10 bar
Direct
16 mm
98015 NAMUR & Inline G1/4, 1/4NPT, G1/2, 1/2 NPT 0 … 10 bar
Direct
30.5; 38.5; 47.5 Depends of solenoids
21000 G1/2 up to 50 bar max.
Direct
30.5; 38.5; 47.5 Depends of solenoids
23200 G1/2, G1 up to 100 bar max.
30.5; 38.5; 47.5 Depends of solenoids
24000 G1/4, G1/2 up to 100 bar max.
Indirect Indirect Indirect Indirect Indirect Indirect Indirect Indirect Direct Direct Direct
For further information www.imi-precision.com
Direct
Direct
16
95000 Inline G1/4, 1/4 NPT, G1/2 up to 40 bar max.
96000 Inline G1/4, 1/4 NPT up to 10 bar max.
6316 Inline G1/4,1/4 NPT 0 … 8 bar
SIL Certification (IEC 61508)
M/O with manual override
M/O without manual override
M/O-add-on manual override
Spool valves
Seat valves
NAMUR Flange
Stainless steel
Cast iron
Brass
Black anodised Aluminium
Anodised Aluminium
5/3 All ports blocked
5/2 Impulse
3/2 » 5/2 With adapter plate
5/2 Spring return
3/2
2/2
Solenoid space tube Ø 9 mm 13 mm 13 mm 9 mm 13 mm 13 mm 16 mm
98025 NAMUR & Inline G1/2, 1/2 NPT 2 … 8 bar
13 mm
26360, 80207 Inline G1/4 up to 10 bar max.
13 mm
26360, 80207 NAMUR G1/4 up to 10 bar max.
16 mm
97300 NAMUR G1/4, 1/4 NPT 2 … 8 bar
Indirect
97105 Inline G1/4, 1/4 NPT, G1/2, 1/2 NPT 2.5 … 8 bar
Zone 1, 2 II2G
NEMA
Solenoid - Model Power consumption
Solenoid - Model Power consumption
3039
382x
Solenoid - Model Power consumption
Solenoid - Model Power consumption
Solenoid - Model Power consumption
Solenoid - Model Power consumption
Solenoid - Model Power consumption
Solenoid - Model Power consumption
13xx, 150x, 16xx
144x, 157x
42xx
46xx
2003 & 205x
48xx
3039 37 mA II 2G Ex ia IIC T4/ T6 Gb II 2D Ex ia IIIC T80°C Db II 2D Ex ia IIIC T100°C Db
3034 0,7 W
3050 1,8 W
3034 2,0 VA 4200 0,8 W; 4201 1,3 VA II 2G Ex eb mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
4600/4602 0,8 W; 4601/4603 1,3 VA II 2G Ex d mb IIC T5/T6 Gb II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
2050 … 2053 II 2G Ex ia IIC T4/ T6 Gb II 2D Ex ia IIIC T80°C Db II 2D Ex ia IIIC T100°C Db
4802 0,8 W; 4803 1,3 VA III 2G Ex mb d IIC T4/T6 II 2G Ex mb e IIC T4/T6
4200 0,8 W; 4201 1,3 VA II 2G Ex eb mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
4600/4602 0,8 W; 4601/4603 1,3 VA II 2G Ex d mb IIC T5/T6 Gb II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
2050 … 2053 II 2G Ex ia IIC T4/ T6 Gb II 2D Ex ia IIIC T80°C Db II 2D Ex ia IIIC T100°C Db
4802 0,8 W; 4803 1,3 VA II 2G Ex mb d IIC T4/T6 II 2G Ex mb e IIC T4/T6
4210 3,9 W; 4211 5,3 VA II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
4610/4612 3,9 W; 4611/4613 5,3 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
4210 3,9 W; 4211 5,3 VA II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
4610/4612 3,9 W; 4611/4613 5,3 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
0763 2,1 VA
4200 0,8 W; 4201 1,3 VA II 2G Ex eb mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
4600/4602 0,8 W; 4601/4603 1,3 VA II 2G Ex d mb IIC T5/T6 Gb II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
0827 6,8 W 0800 16,9 W 3805 10,6 VA 3803 19,5 VA
4260 3,9 W/4270 8,9 W 4261 5,3 VA/4271 10,0 VA II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
4660/4662 3,9 W; 4670/4672 8,9 W 4661/4663 5,3 VA; 4671/4673 10,0 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
0763 1,9 W 0763 2,1 VA 0763 1,9 W 0763 2,1 VA
1
3036 1,6 W
3050 1,8 W
3036 3,5 VA 0242 2,7 W 0245 4,2 VA 0242 2,7 W 0245 4,2 VA 0763 1,9 W
4872 8,9 W; 4873 10,0 VA II 2G Ex mb d IIC T4/T6 II 2G Ex mb e IIC T4/T6 2003 II 2G Ex ia IIC T5/T6 II 2D Ex tD A21 IP66 T95°C
0800 16,9 W
4270 8,9 W; 4271 10,0 VA II 2G Ex eb mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db IP66
3803 19,5 VA
0246 8,0 W 0200 12,1 W
0700 16,9 W 0800 16,9 W
3206 9,2 VA 3204 11,3 VA
3703 19,5 VA 3803 19,5 VA
0246 8,0 W 3206 9,2 VA
1300 21,4 W; 1500 38,7 W 1301 22,8 VA; 1501 42,1 VA
1300 21,4 W; 1500 38,7 W 1600 52,3 W 1301 22,8 VA; 1501 42,1 VA 1601 56,4 VA
1300 21,4 W; 1500 38,7 W 1301 22,8 VA; 1501 42,1 VA
4670/4672 8,9 W; 4671/4673 10,0 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
1440 21,4 W; 1570 38,7 W 1441 22,8 VA; 1571 42,1 VA 1440 & 1441: II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T120°C Db IP65 1570 & 1571: II 2G Ex e mb IIC T4 Gb 1440 21,4 W; 1570 38,7 W 1441 22,8 VA; 1571 42,1 VA 1440 & 1441: II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T120°C Db IP65 1570 & 1571: II 2G Ex e mb IIC T4 Gb 1440 21,4 W; 1570 38,7 W 1441 22,8 VA; 1571 42,1 VA 1440 & 1441: II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T120°C Db IP65 1570 & 1571: II 2G Ex e mb IIC T4 Gb
1570 38,7 W 1571 42,1 VA II 2G Ex e mb IIC T4 Gb
4210 3,9 W/4211 5,3 VA II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db 4220 8,9 W/4221 10,0 VA 4230 11,4 W/4280 11,4 W 4231 15,2 VA/4281 15,2 VA II 2G Ex eb mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db 4210 3,9 W; 4211 5,3 VA II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
4610/4612 3,9 W; 4620/4622 8,9 W 4611/4613 5,3 VA; 4621/4623 10,0 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db 4630/4632 11,4 W; 4680/4682 11,4 W 4631/4633 15,2 VA; 4681/4683 15,2 VA II 2G Ex d mb IIC T4/T5 Gb II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db 4610/4612 3,9 W; 4611/4613 5,3 VA II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
4872 8,9 W; 4873 10,0 VA II 2G Ex mb d IIC T4/T6 II 2G Ex mb e IIC T4/T6
3824 8,9 W; 3826 13,6 W 3825 9,5 VA; 3827 15,7 VA Cl. I, Div. 1, Gr. A - D Cl. II/III, Div. 1, Gr. E - G T3C (160°C) NEMA 4X
For further information www.imi-precision.com
97105 NAMUR G1/4, 1/4 NPT, G1/2, 1/2 NPT 2.5 … 8 bar
Solenoid - Model Solenoid - Model Solenoid - Model Solenoid - Model Power Power Power Power consumption consumption consumption consumption 07xx/08xx/ 305x 02xx 3803/3805 303x
II2G
18
97100 Inline G1/4, 1/4 NPT 2 … 8 bar
Zone 1, 2, 21, 22 II 2G / II 2D
II 2G / II 2D
VALVES
VALVES
Actuated
IP65
Direct
1
Product Selector
Zone 1, 2, 21, 22
SIL Certification (IEC 61508)
M/Owith manual override
M/Owithout manual override
M/Oadd-on manual override
Stainless steel
Cast iron
Brass
2/2
8171
840x / 940x
Indirect actuated
9101 8,0 W 9151 18,0 W 9101 15,0 VA 9151 45,0 VA
Direct actuated Indirect actuated Pneumatically actuated Direct actuated Pneumatically actuated
84500 ASPV G1/2 … G2 up to 25 bar
84520 ASPV G1/2 … G2 up to 25 bar
9191
6120 18 W 6126 14 W 6120 20 VA 6126 16 VA Ex eb mb IIC T4 Gb Ex eb mb IIC T3 Gb Ex mb tb IIIB Ex mb tb IIIB T125°C Db T140°C Db
9186 14,0 W 9186 16,0 VA Ex em II T4 T140°C
9191 18,0 W 9191 20,0 VA Ex em II T3 T140°C
6120 18 W 6126 14 W 6120 20 VA 6126 16 VA Ex eb mb IIC T4 Gb Ex eb mb IIC T3 Gb Ex mb tb IIIB Ex mb tb IIIB T125°C Db T140°C Db
9186 14,0 W 9186 16,0 VA Ex em II T4 T140°C
9191 18,0 W 9191 20,0 VA Ex em II T3 T140°C
6176
6246
6240
6106
8186
84xx
8920
6106 8 W 6106 9 VA Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db
9136
9136 8,0 W 9136 9,0 VA Ex m II T4 T130°C
9136 8,0 W 9136 9,0 VA Ex m II T4 T130°C
46xx 4670 9,0 W II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db 4680 10,0 W II 2G Ex d mb IIC T4/T5 Gb II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
382x
4670 9,0 W II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db 4680 10,0 W II 2G Ex d mb IIC T4/T5 Gb II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
3826 13,6 W 3827 15,7 VA Cl. I, Div. 1, Gr. A,B, C, D Cl. II/III, Div. 1, Gr. E, F, G T3C (160°C) NEMA 4X
1
3826 13,6 W 3827 15,7 VA Cl. I, Div. 1, Gr. A,B, C, D Cl. II/III, Div. 1, Gr. E, F, G T3C (160°C) NEMA 4X
9401 38,0 W
9151 18,0 W
9404 42,0 VA
9154 20,0 VA
9401 38,0 W
9151 18,0 W
9404 42,0 VA
9154 20,0 VA
6120 18 W 6120 20 VA Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db
9191 18,0 W 9191 20,0 VA Ex em II T3 T140°C
6120 18 W 6120 20 VA Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db
9191 18,0 W 9191 20,0 VA Ex em II T3 T140°C
6176 9 W 6176 10 VA Ex eb mb IIC T4 Gb Ex mb tb IIIB T135°C Db
8171 12,0 W 8171 23,0 VA
9401 38,0 W 8401 40,0 W 9404 42,0 VA 8404 45,0 VA 9401 38,0 W 8401 40,0 W 9404 42,0 VA 8404 45,0 VA
8401 40,0 W
9501 80,0 W
8404 45,0 VA
9504 89,0 VA
8186 9,0 W 8186 10,0 VA Ex em II T4 T140°C
6246 14 W 6246 16 VA Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db
6240 18 W 6240 20 VA Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db
8436 32,0 W; 8436 36,0 VA Ex em II T4 T140°C 8441 40,0 W; 8441 45,0 VA Ex me II T3 T140°C
8920 29,0 W 8920 33,0 VA Ex d II C T4/T5 T130°C/T95°C
6246 14 W 6246 16 VA Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db
6240 18 W 6240 20 VA Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db
8436 32,0 W; 8436 36,0 VA Ex em II T4 T140°C 8441 40,0 W; 8441 45,0 VA Ex me II T3 T140°C
8920 29,0 W 8920 33,0 VA Ex d II C T4/T5 T130°C/T95°C
6246 14 W 6246 16 VA Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db
6240 18 W 6240 20 VA Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db
8436 32,0 W; 8436 36,0 VA Ex em II T4 T140°C 8441 40,0 W; 8441 45,0 VA Ex me II T3 T140°C
8920 29,0 W 8920 33,0 VA Ex d II C T4/T5 T130°C/T95°C
For further information www.imi-precision.com
For further information www.imi-precision.com
85780 with forced lifting flange version 0 … 25 bar
9186
NEMA
21
19
82590 with forced lifting G1/4 … G1 up to 10 bar
85540 with forced lifting flange version 0 … 25 bar
6120
II 2G/II 2D
9101 15,0 VA
82540 with forced lifting G1/4 … G1 up to 10 bar
85500 with forced lifting flange version 0 … 25 bar
6126
II 2GD
9101 8,0 W
82470 Differential pressure G1/4 … G1 up to 10 bar
82900 High flow G3/4 … G1, 3/4 NPT … 1 NPT 0.4 … 8 bar
950x
9101 15,0 VA 9151 45,0 VA
82730 Differential pressure G1/4 … G1 up to 16 bar
82960 High flow G3/4 … G3, 3/4 NPT … 2 1/2 NPT 0.4 … 8 bar
91xx 9101 8,0 W 9151 18,0 W
82400 Differential pressure G1/4 … G2 up to 16 bar
Zone 1, 2, 21, 22
II 2G
VALVES
VALVES
Aluminium
IP65
Function
1
Product Selector
1
Fast Find Guide
VALVES
IMI Herion valves - Removable solenoids NAMUR & Inline - Solenoid operated valves, indirect actuated 97100 Inline
97105 Inline
3/2, 5/2, 5/3 1/4”
2 … 8 bar ALU
97105 NAMUR
3/2, 5/2, 5/3 1/4”, 1/2”
Page 24
2,5 … 8 bar ANO, SS
Page 25
98025 NAMUR & Inline
6215M NAMUR & Inline
2 … 8 bar ANO
ANO
3/2 1/2”
Page 33
97300 NAMUR
3/2, 5/2, 5/3 1/4”, 1/2”
2,5 … 8 bar ANO, SS
3/2, 5/2 1/4”
Page 26
2 … 8 bar ALU
26360 & 80207 Inline
26360 & 80207 NAMUR
1 … 10 bar ALU
1 … 10 bar ALU
3/2, 5/2 1/4”, 1/2”
Page 29
Page 30
3/2, 5/2 1/4”
Page 31
6215L NAMUR & Inline
3/2,5/2 1/4”
3/2,5/2 1/4”
Page 35
Page 37
ANO
NAMUR & Inline - Solenoid operated valves, direct actuated 24011 NAMUR & Inline
24010 NAMUR & Inline
98015 NAMUR & Inline
21000
0 … 10 bar ANO, BR, SS
0 … 10 bar ANO, BR, SS
0 … 10 bar ANO, BR, SS
0 … 50 bar BR
3/2 1/4”
22
Page 39
95000
3/2 1/4”, 1/2”
Page 43
96000
2/2 1/4”, 1/2”
For further information www.imi-precision.com
0 … 40 bar BR
3/2 (Ex ia) 1/4”
0 … 10 bar BR
Page 44
24000
2/2 G1/2”, G 1"
Page 46
3/2 1/4”, 1/2”
0 … 50 bar BR
Page 47
0 … 100 bar BR
Page 48
6316 Inline
3/2 1/4"
Page 50
23200
2/2 1/2"
3/2 1/4"
Page 51
ANO, BR, SS
Page 56
IMI Maxseal valves - Integrated solenoids - ATEX Zone 0 ICO3S EX IA - direct actuated YX1 Inline 3/2, 5/2 1/4”
0 … 12 bar SS
Page 57
IMI Maxseal valves - Integrated solenoids - ATEX Zone 1 ICO3S - Direct actuated ICO4S - Direct actuated ICO4-PST - Electromagnetic actuated Y01 Inline
Y1 Inline
3/2, 5/2 1/4”, 1/2”
0 … 12 bar SS
ALU
Y41 Poppet valve
3/2, 5/2 1/4”, 1/2”
0 … 20 bar SS
Page 58
Anodised Aluminium
3/2 1/4” … 3/4”
ANO
Black anodised Aluminium
BR
0 … 10 bar SS
Page 59
Brass
SS
Stainless Steel
CAS
Cast iron
Page 63
CAI
Casting stainless steel
Fast Find Guide
1
82400 82730
82470
82540 82590
2/2 1/4 … 1"
2/2 1/4 … 2"
0,1 … 16 bar BR, SS
Page 64
0,1 … 10 bar BR
82960, 82970
Page 66
82900, 82910
2/2 3/4” … 3”
2/2 1/4 … 2"
0 … 10/16 bar BR, SS
Page 67
VALVES
IMI Buschjost diaphragm valves 2/2 3/4 … 1"
0,4 … 8 bar ALU
Page 68
0,4 … 8 bar ALU
Page 69
IMI Buschjost piston seat valves 85500
85540
2/2 Flange version
85780
2/2 Flange version
0 … 25 bar CAS, BR
Page 70
0 … 25 bar SS
2/2 Flange version
Page 70
0 … 25 bar SS
Page 71
IMI Buschjost angle seat pilot valves 23
84500 84520
2/2 1/2 … 2"
Page 72
For further information www.imi-precision.com
0 … 10/16 bar BR, SS
Redundant valve manifolds - 1oo2, 2oo2, 2oo3 V81 - IMI Herion Modular with Bypass
V82 - IMI Herion Compact
0 … 10 bar AA, SS
0 … 0 bar AA, SS
1/4", 1/2"
Page 73
1/4", 1/2"
V83 - IMI Maxseal Modular with Bypass
V84 - IMI Maxseal Compact
0 … 10 bar AA, SS
0 … 12 bar AA, SS
1/4", 1/2"
Page 73
1/4", 1/2"
Page 73
Page 73
IMI Herion Boosters Inline - Pneumatically actuated valves 80400
3/2 1/2” … 1 1/2”
0 … 10 bar SS
ALU
Page 77
Anodised Aluminium
ANO
Black anodised Aluminium
BR
Brass
SS
Stainless Steel
CAS
Cast iron
CAI
Casting stainless steel
1
97100 Inline
VALVES
• 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled • G1/4, 1/4 NPT The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category 2of solenoids(see table of solenoids).
V-32C-EM-S
1
3 4
2
4 3 4
1 2 1
Medium: Filtered, non-lubricated or dry compressed air Operating pressure: 2 … 8 bar (29 … 116 psi) Fluid/Ambient temperature: -15°C … +60°C (-5°F … 140°F) Depending on solenoid system.
Materials: Housing: Anodized Aluminium Pilot flange: Plastic (PBT) Seals: NBR
Approved
Approval depends on magnetic system
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
V-52-EM-S
2 513 Technical data
Symbol
Manual override with detent standard
Technical features
2 2
54 1 51 4 3 5 41
3 2 3 2 32
54 1 51 4 51
2 3 3 2 3
V-32C-EMH-S Model *1) V-52B-EM V-52-EMH-S 9713032 V-32C-EMH-S 9713042 V-53A-EM
513 4 2
Port size
Function
Actuation/Return
Operating pressure (bar)
Flow (l/min)
G1/4
3/2
Solenoid/air spring
2…8
750
1/4 NPT
3/2
Solenoid/air spring
2…8
750
V-52B-EMH 9710032 V-52-EMH-S 9710042 V-53A-EMH 9711032 V-52B-EMR 9711042
G1/4
5/2
Solenoid/air spring
2…8
750
1/4 NPT
5/2
Solenoid/air spring
2…8
750
G1/4
5/2
Solenoid/Solenoid
2…8
750
1/4 NPT
5/2
Solenoid/Solenoid
2…8
750
9712032 V-53A-EMR 9712042
G1/4
5/3 APB
Solenoid/Solenoid
2…8
500
1/4 NPT
5/3 APB
Solenoid/Solenoid
2…8
500
513
*1) When ordering, please indicate solenoid, voltage and current (frequency). Valve function: APB = All Ports Blocked.
24
Solenoid Model
For further information www.imi-precision.com
3050
Power consumption 24 V DC 230 V AC (W) (VA) 1,8 –
Rated current 24 V DC (mA) 70
230 V AC (mA) –
IP-Protection
Ex-Protection (ATEX-Category)
Temperature Ambient/ Medium (°C)
IP65 (Connector DIN EN 175301-803, Form B) *2)
–
-15 … +50
3034
0,7
2,0 *3)
29
4
IP65 (Connector DIN EN 175301-803, Form B) *2)
–
-15 … +50
3062
2,7
–
115
–
IP65 (with 3 m cable)
II 2G Ex mb IIC T5 Gb II 2D Ex mb tb IIIC T95°C Db
-20 … +50
3063
–
2,1
–
9
IP65 (with 3 m cable)
II 2G Ex mb IIC T5 Gb II 2D Ex mb tb IIIC T95°C Db
-20 … +50
Standardvoltages 24 V d.c., 230 V a.c., other voltages on request. *2) Connector is not scope of delivery, see table »Accessories«.
*3) Valves can be operated with DC only. For 230V AC application please use 206V DC coil together with recifier plug 0663303.
For intrinsically safe circuits, Protection class II 2G Ex ia IIC T4/T6 Ga Model
Nominal resistance RN Coil (Ω)
Required switching min. Current min (mA)
Rated currentIon RW 50 Coil (Ω)
Required switching at terminal RW 50 (V)
Temperature Ambient/Medium (°C)
3039 *4)
275
37
345
13,8
T6: -40 … +50 T4: -40 … +85
When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken in account.
On the other hand, the low effective inductivity and capacity can be ignored. *4) Connector not supplied, required connector: model 0570275.
Accessories Connector DIN EN 175301-803
Approvals Silencer (plastic) *5)
Silencer (stainless steel) *5)
0570275, Form A
M/S2 (G1/4)
0014613 (G1/4)
0663303, Form A (with rectifier)
C/S2 (1/4NPT)
0613678 (1/4 NPT)
0680003, Form B
Exhaust guard *6)
Model
Approvals ATEX FM
306x
PTB 03 ATEX 2015 X
–
3039
PTB 03 ATEX 2134
CSA-LR 51090-4
0613422 (1/4")
*5) For indoors use only. *6) For outdoors use ~ 0,2 (bar).
97105 Inline Technical features
• G1/4, 1/4 NPT, G1/2, 1/2 NPT The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Medium: Filtered, non-lubricated and dried compressed air, instrument air, nitrogen and other non-flammable neutral, dry fluids Operating pressure: 2,5 … 8 bar (36 … 116 psi) with internal air supply 0 … 8 bar (0 … 116 psi) with external air supply Fluid/Ambient temperature: -40°C … +65°C (NBR)(-40°F … +149°F) -25°C … +80°C (HNBR)(-13°F … +176°F) Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP66 protection must be used! Materials: Body: Aluminium with surface treatment for rough environmantal conditions. ( Stainless steel DIN 50018: Condensate test with alternating temperatures in sulphuric atmosphere, DIN 50021/ASTM B117-73: Salt spray test with different sodium chloride solutions, tested in ammonia atmosphere). Stainless steel 1.4404 (316 L) Seals: NBR or HNBR
VALVES
• 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled
1
Add-on manual override
SIL2 @ HFT=0 SIL3 @ HFT=1
Approved
Approval depends on magnetic system
Technical data NBR: -40°C … +65°C / IEC 61508: -40°C … +40°C Symbol
2
Function
Actuation/Return
Operating pressure (bar)
Flow (l/min)
Test certificate IEC 61508
9713535
G1/4
3/2
Solenoid/Spring
2,5 … 8
1300
x
9713545
1/4 NPT
3/2
Solenoid/Spring
2,5 … 8
1300
x
9713555
G1/2
3/2
Solenoid/Spring
2,5 … 8
2600
-
9713565
1/2 NPT
3/2
Solenoid/Spring
2,5 … 8
2600
-
9710535
G1/4
5/2
Solenoid/Spring
2,5 … 8
1300
x
9710545
1/4 NPT
5/2
Solenoid/Spring
2,5 … 8
1300
x
9710555
G1/2
5/2
Solenoid/Spring
2,5 … 8
2600
-
9710565
1/2 NPT
5/2
Solenoid/Spring
2,5 … 8
2600
-
9711535
G1/4
5/2
Solenoid/Solenoid
2,5 … 8
1300
-
1/4 NPT
5/2
Solenoid/Solenoid
2,5 … 8
1300
-
G1/4
5/3 APB
Solenoid/Solenoid
2,5 … 8
950
-
5/3 APB
Solenoid/Solenoid
2,5 … 8
950
-
Port size
Function
Actuation/Return
Operating pressure (bar)
Flow (l/min)
Test certificate IEC 61508
G1/4
3/2
Solenoid/Spring
2,5 … 8
1300
x
V-32C-EM-F 1
3 2 4
1
V-32C-EMH-F
2
V-52-EM-F
3 2
1
513 4 4 3
2 2
51 51 4 4 4
3 3 22 2
V-32C-EMR-F
V-52-EMH-F V-52B-EM 9711545 9712535
V-52-EMH-F V-53A-EM 1/4 NPT 9712545 V-52B-EMH
5 51 13 3 513
*1) When ordering please indicate solenoid, voltage and current type (frequency).
4 4
2 2
V-53A-EMH V-52B-EMR
513 NBR: -40°C … +65°C 5 1 3 / IEC 61508: -40°C … +40°C Symbol
4
Model *1)
2
V-53A-EMR
9713735
513 2
9713745
1/4 NPT
3/2
Solenoid/Spring
2,5 … 8
1300
x
9713755
G1/2
3/2
Solenoid/Spring
2,5 … 8
2600
-
V-32C-EM-F 1
3 2 4
1
513 4 4 3
1/2 NPT
3/2
Solenoid/Spring
2,5 … 8
2600
-
G1/4
5/2
Solenoid/Spring
2,5 … 8
1300
x
V-32C-EMH-F
9710745
1/4 NPT
5/2
Solenoid/Spring
2,5 … 8
1300
x
9710755
G1/2
5/2
Solenoid/Spring
2,5 … 8
2600
-
V-52-EM-F
3 2
1
2
9713765 9710735
2 2
513 513
9710765
1/2 NPT
5/2
Solenoid/Spring
2,5 … 8
2600
-
9711735
G1/4
5/2
Solenoid/Solenoid
2,5 … 8
1300
-
1/4 NPT
5/2
Solenoid/Solenoid
2,5 … 8
1300
-
V-32C-EMR-F
V-52-EMH-F V-52B-EM 9711745
4 solenoid, 2 *1) When ordering please indicate voltage and current type (frequency). 4 2 513 513 4
V-52-EMH-F V-52B-EMH
2
V-52B-EMR
For further information www.imi-precision.com
Port size
25
Model *1)
1
97105 NAMUR
VALVES
• 3/2, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled
Add-on manual override
Technical features
Medium:
• G1/4, 1/4 NPT, G1/2, 1/2 NPT, flanged with NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Filtered, non-lubricated and dried compressed air, instrument air, nitrogen and other non-flammable neutral, dry fluids Operating pressure: 2,5 … 8 (36 … 116 psi) with internal air supply 0 … 8 bar (0 … 116 psi) with external air supply (G1/2, 1/2 NPT or low power pilot system only) Fluid/Ambient temperature: Valve: -40°C … +65°C (NBR) (-40°F … +149°F) -25°C … +80°C (HNBR) (-13°F … +176°F) Depending on solenoid system.
Materials: Body: Aluminium 3.0615 with surface treatment for rough environmantal conditions. Approved according to DIN 50018: Condensate test with alternating temperatures in sulphuric atmosphere, DIN 50021/ ASTM B117-73: Salt spray test with different sodium chloride solutions, tested in ammonia atmosphere). Stainless steel 1.4404 (316 L) Seals: NBR or HNBR SIL2 @ HFT=0 SIL3 @ HFT=1
Approved
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Approval depends on magnetic system
For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP66 protection must be used!
26
Technical data Housing: Aluminium anodized, NBR: -40°C … +65°C / IEC 61508: -40°C … +40°C For further information www.imi-precision.com
Symbol
4
2
4
2
V-32spec-EM-F
4
2
4
2 5 13
4
2
V-32spec-EMH-F
4 2 513
V-32spec-EM-EM 54 1 32
45 13 2
V-32spec-EMR-F
*1) When ordering please (frequency). 4 indicate 2 solenoid, voltage and current type 4 2
5 13
Housing: Symbol
5 13 Stainless 4
513
V-32spec-EMH-EMH
4
2
V-32spec-EMR-EMR 54 1 32
3 45 12
V-32spec-EM-F 44
22 55 11 33
Actuation/Return
Operating pressure (bar)
Flow (l/min)
Test certificate IEC 61508
9710505
G1/4 NAMUR
Solenoid/Spring
2,5 … 8
1300
x
9710515
1/4 NPT NAMUR
Solenoid/Spring
2,5 … 8
1300
x
9710595
G1/2 NAMUR
Solenoid/Spring
2,5 … 8
2600
–
9710596
1/2 NPT
Solenoid/Spring
2,5 … 8
2600
–
Solenoid/Solenoid
2,5 … 8
1300
–
Solenoid/Solenoid
2,5 … 8
1300
–
Actuation/Return
Operating pressure (bar)
Flow (l/min)
Test certificate IEC 61508
G1/4 NAMUR
Solenoid/Spring
2,5 … 8
1300
x
9710715
1/4 NPT NAMUR
Solenoid/Spring
2,5 … 8
1300
x
9711705
G1/4 NAMUR
Solenoid/Solenoid
2,5 … 8
1300
–
Solenoid/Solenoid
2,5 … 8
1300
–
V-52-EMH-F 9711505
G1/4 NAMUR
V-52B-EM 9711515 1/4 NPT NAMUR V-52-EMH-F V-52B-EMH
3 steel, NBR: -40°C 5…1 +65°C / IEC 61508: -40°C … +40°C
2
5 13
Port size
V-52-EM-F 513
5 13
Model *1)
Model *1)
V-52B-EMR 9710705
V-52-EM-F 513 4 4
2 2
V-32spec-EM-EM V-32spec-EMH-F 513
Port size
V-52B-EM V-52-EMH-F 9711715 1/4 NPT NAMUR
*1) When ordering please 4 2 4 indicate 2 solenoid, voltage and current type (frequency).
4
2
5 13 5 13 4
2
4
2
V-32spec-EMH-EMH V-32spec-EMR-F 4
2
V-32spec-EMR-EMR 5 13
V-52B-EMH V-52-EMH-F
5 51 13 3
513
V-52B-EMR
97105 NAMUR & Inline
1
Solenoids
Model
Power consumption
Rated current
Ex-Protection (ATEX-Category)
Temperature Ambient/ Medium (°C)
Electrical connection
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
0763
1,9
2,1
78
11
IP65 (with Connector)
–
-25 … +60
DIN EN 175 301-803 Form A *2) *3)
4200
0,8
–
38
–
IP66 (with cable II 2G Ex eb mb IIC T5/T6 Gb gland) II 2D Ex tb IIIC T130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
M20 x 1,5 *3)
4201
–
1,3
–
6
IP66 (with cable II 2G Ex eb mb IIC T5/T6 Gb gland) II 2D Ex tb IIIC T130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
M20 x 1,5 *3)
4600
0,8
–
33
–
IP66 (with cable II 2G Ex d mb IIC T5/T6 Gb gland) II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
1/2 NPT *3)
4602
0,8
–
33
–
IP66 (with cable II 2G Ex d mb IIC T5/T6 Gb gland) II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
M20 x 1,5 *3)
4601
–
1,3
–
6
IP66 (with cable II 2G Ex d mb IIC T5/T6 Gb gland) II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
1/2 NPT *3)
4603
–
1,3
–
6
IP66 (with cable II 2G Ex d mb IIC T5/T6 Gb gland) II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
M20 x 1,5 *3)
4802
0,8
–
33
–
IP66 (with cable II 2G Ex mb d IIC T4/T6 Gb gland) II 2G Ex mb e IIC T4/T6 Gb
T4: -40 … +50 T6: -40 … +40
M20 x 1,5 *3)
1,3
–
6
IP66 (with cable II 2G Ex mb d IIC T4/T6 Gb gland) II 2G Ex mb e IIC T4/T6 Gb
T4: -40 … +50 T6: -40 … +40
M20 x 1,5 *3)
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *2) Required connector: model 0570275 for V DC; model 0663303 for V AC, to be ordered Solenoid Voltage 200V DC! *3) Connector cable gland not supplied, see table »Accessories«. Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals Model
Approvals ATEX IECEx
42xx
KEMA 98 ATEX 4452 X
IECEx KEM 09.0068X
46xx
PTB 02 ATEX 2085 X
IECEx PTB 11.0094X
48xx
PTB 06 ATEX 2054 X
IECEx PTB 07.0039X
For further information www.imi-precision.com
4803
27
IP-Protection
VALVES
Solenoids
1
97105 NAMUR & Inline Solenoids and accessories
VALVES
Solenoid actuators for intrinsically-safe circuits Model
Nominalresistance RN coil (Ω)
Min. required switching current (mA)
Resistance RW 60 Coil (Ω)
Required voltageat terminal Rw 60 (V)
2050
200
33
240
8
2051
391
24
460
11
2052
736
17
880
15
2053
1220
13
1460
19
IP-Protection
IP66 (with cable gland)
Ex-Protection (ATEX-Category)
Temperature Ambient/Medium (°C)
II 2G Ex ia IIC T6 Gb II 2G Ex ia IIC T4 Gb II 2D Ex iaD 21 T80°C Db II 2D Ex iaD 21 T100°C Db
T4: -40 … +60 T6: -40 … +80 -40 … +60 -40 … +80
Cable gland (cable Ø 5 … 10 mm) is in scope of delivery. When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken into account. Ui = 45 V Ii = 500 mA according to Tab. A. 1, EN 60079-11. Pi = 2,0 W, Li and Ci can be ignored.
Approvals Model
Approvals ATEX IECEx FM
205x
PTB 07 ATEX 2019 X
IECEx PTB 07.0017
–
Accessories Cable gland Protection Ex e, Ex d (ATEX)
28
For further information www.imi-precision.com
Model
For solenoid
Thread
Cable Ø (mm)
Material
Protection class (ATEX)
Ambient temperature limitation
0589735
42xx
M20 x 1,5
7,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *4)
0589736
42xx
M20 x 1,5
10,0 … 14,0
Plastic
II 2G Ex e / II 2D Ex t
See table *4)
0589737
42xx
M20 x 1,5
6,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *4)
0588819
46xx
M20 x 1,5
5,0 … 8,0
Nickel plated brass
II 2G Ex e / II 2D Ex t
–
0588851
46xx
M20 x 1,5
10,0 … 14,0
Nickel plated brass
II 2G Ex d / II 2D Ex t
–
0588925
46xx
1/2 NPT
7,5 … 11,9
Nickel plated brass
II 2G Ex d / II 2D Ex t
–
0589385
46xx, 48xx
M20 x 1,5
9,0 … 13,0
Stainless steel 1.4571
II 2G Ex e / II 2D Ex t
–
0589395
46xx, 48xx
M20 x 1,5
7,0 … 12,0
Stainless steel 1.4404
II 2G Ex d / II 2D Ex t
–
0589387
46xx, 48xx
M20 x 1,5
10,0 … 14,0
Stainless steel 1.4404
II 2G Ex d / II 2D Ex t
-
*4) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.
For solenoid
420x/425x
Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *5)
0589737
T5 & Dust Ex: -35°C … + 80°C
T5 & Dust Ex: -40°C … +68°C
T6: -35°C … +70°C
T6: -40°C … +68°C
*5) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.
Connector DIN EN 175301-803
Silencer (plastic) *6)
Silencer (stainless steel) *6)
Exhaust guard *7)
Add-on manual override
Add-on manual override (for start-up only)
0570275, Form A
M/S2 (G1/4)
0014613 (G1/4)
0613422 (1/4")
0553886 (without detent)
0613379 (without detent)
0613423 (1/2")
0553887 (with detent, return at pressure failure)
0663303, Form A (with rectifier)
C/S2 (1/4 NPT)
0613678 (1/4 NPT)
M/S4 (G1/2)
0014813 (G1/2)
C/S4 (1/2 NPT)
0613679 (1/2 NPT)
*6) For indoors use only. *7) For outdoors use ~ 0,2 (bar). *8) Use function descrption 75036430.
0614084 (with detent) *8)
97300 NAMUR Manual override with detent • 3/2- & 5/2-Spool valves electromagnetic actuated, indirectly controlled • G1/4, 1/4 NPT, flanged with NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
VALVES
Technical features Medium: Filtered, lubricated or non-lubricated and dry compressed air Operating pressure: 2 … 8 bar (29 … 116 psi) (below -10°C >must be > 2,5 bar (36psi)) Fluid/Ambient temperature: -15°C … +50°C (-5°F … +122°F) Depending on solenoid system.
Materials: Housing: Aluminium anodized Pilot flange: Pilot flange: Plastic (PBT) Flange plate: Aluminium Seals: NBR
Approval depends on magnetic system
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
4 Technical data Symbol
4
2
4 4
V-52-EM-F
513
2 2
44
2 2
V-32spec-EM-EM V-32spec-EMH-F
5 13 5 13 4 4
2
V-32spec-EM-F
5 13
4 4
2 2
V-32spec-EMH-EMH V-32spec-EMR-F
5 13 5 13
Model *1)
Port size
Actuation/Return
Operating pressure (bar) *2)
Flow (l/min)
9730000
G1/4 NAMUR
Solenoid/Spring
2…8
1230
9730010
1/4 NPT NAMUR
Solenoid/Spring
2…8
1230
9731000
G1/4 NAMUR
Solenoid/Solenoid
2…8
1250
Solenoid/Solenoid
2…8
1250
V-52B-EM V-52-EMH-F
513
2 2
1
V-52B-EMH V-52-EMH-F 9731010 1/4 NPT NAMUR
55 11 33
*1) When ordering please indicate solenoid, voltage and current type (frequency). 4 2 *2) Below -10°C must4be > 2,52bar.
V-32spec-EMR-EMR
V-52B-EMR
29
Solenoids
513
5 13 Model
Rated current
IP-Protection
Ex-Protection (ATEX-Category)
Temperature Ambient/Medium (°C)
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
3050
1,8
4,3
70
–
IP65 (Connector DIN EN 175301-803, Form B) *3)
–
-15 … +50
3036
1,6
3,5
30
–
IP65 (Connector DIN EN 175301-803, Form B) *3)
–
-15 … +50
3062
2,7
–
115
–
IP65 (with 3 m cable) II 2G Ex mb IIC T5 Gb II 2D Ex mb tb IIIC T95°C Db
-20 … +50
3063
–
2,1
–
9
IP65 (with 3 m cable) II 2G Ex mb IIC T5 Gb II 2D Ex mb tb IIIC T95°C Db
-20 … +50
Ex e mb IIC T4 Gb Ex tb IIIC T120°C Db I IP 65 (with cable gland) Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. *3) Connector is not scope of delivery, see table »Accessories«.
Approval Model
Approval ATEX
306x
PTB 03 ATEX 2015
Accessories Connector DIN EN 175301-803
Silencer (plastic) *4)
Exhaust guard *5)
0570275, Form A
C/S2 1/4 NPT
0613422 (1/4")
0680003, Form B
M/S2 G1/4
*4) For indoors use only. *5) For outdoors use ~ 0,2 (bar).
For further information www.imi-precision.com
Power consumption
1
26360 & 80207 Inline
VALVES
• 3/2- & 5/2-Spool valves electromagnetic actuated, indirectly controlled
Manual override with and without detent
Technical features
• G1/4, G1/2 The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Medium: Filtered, lubricated or non-lubricated Air Operating pressure: 1 … 10 bar (14 … 145 psi); G1/4 1,5 … 10 bar (21 … 145 psi); G1/2 2 … 10 bar (29 … 145 psi); G1/2 Fluid/Ambient temperature: -10°C … +60°C (+14°F … +140°F) -20°C (-4°F) on request Depending on solenoid system.
Materials: Housing: aluminium anodized Pilot flange: plastic (POM) Seals: NBR
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Approval depends on magnetic system
2
30
Technical data 3/2-Way
V-32C-EM-S 1
3 2
Symbol
Model V-32C-EMH-S
1 2
For further information www.imi-precision.com
1
3 4
Port size
Operating pressure (bar)
Flow (l/min)
Manual override with detent
8020765
G1/4
1 … 10
1200
with
V-32C-EMH-S 8020865
G1/2
1,5 … 10
3000
with
Port size
Operating pressure (bar)
Flow (l/min)
Manual override with detent
G1/4
1 … 10
1200
with
2637065
G1/2
2 … 10
3000
with
2636265
G1/4
1 … 10
1200
with
G1/2
2 … 10
3000
with
*1)
3
2
*1) When ordering, please indicate solenoid, voltage and current (frequency).
V-52-EM-S
513
5/2-Way
4 4
2 2
V-52B-EM V-52-EMH-S Model
Symbol
5 51 13 3
*1)
4 4
2636065
2 2
V-52B-EMH V-52-EMH-S 5 51 13 3 4
2
513
V-52B-EMR 2637265
*1) When ordering, please indicate solenoid, voltage and current (frequency).
26360 & 80207 NAMUR Manual override with and without detent
Technical features
• G1/4, NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Medium: Filtered, lubricated or non-lubricated Air Operating pressure: 1 … 10 bar (14 … 145 psi) Fluid/Ambient temperature: -10°C … +60°C (+14°F … +140°F) Depending on solenoid system
Materials: Housing: aluminium anodized Pilot flange: plastic (POM) Seals: NBR
VALVES
• 3/2- & 5/2-Spool valves electromagnetic actuated, indirectly controlled
1
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Approval depends on magnetic system
2
V-AE-32C-EM-F 1 3 2
3
Symbol
31
Technical data 3/2-Way
3
Model *1) V-AE-32C-EMH-F
Port size
Operating pressure (bar)
Flow (l/min)
Manual override with detent
G1/4 NAMUR
1 … 10
1200
with
1 3 2
3
8020747
*1) When ordering, please indicate solenoid, voltage and current (frequency).
4
2
V-52-EM-S
5/2-Way Symbol
513 4 4
2 2
513 513 44
22
513 513 4
2
Model
Port size
Operating pressure (bar)
Flow (l/min)
Manual override with detent
2636047
G1/4 NAMUR
1 … 10
1200
with
G1/4 NAMUR
1 … 10
1200
with
V-52-EMH-S *1) V-52B-EM
V-52-EMH-S V-52B-EMH 2636247
V-52B-EMR 513 *1) When ordering, please indicate solenoid, voltage and current (frequency).
For further information www.imi-precision.com
V-AE-32C-EMR-F 1 3
1
26360 & 80207 NAMUR & Inline Solenoids and accessories
VALVES
Solenoids Model
Power consumption
Rated current
IP-Protection
Ex-Protection (ATEX-Category)
Temperature Ambient/ Medium (°C)
Electrical connection
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
0242
2,7
–
113
–
–
-25 … +60 Fluid: max. 80
Connector DIN EN 175301-803 Form A *2)
0245
–
4,2
–
–
IP65 (with Connector)
–
-25 … +60 Fluid: max. 80
Connector DIN EN 175301-803 Form A *2)
4210
3,9
–
162
–
IP66 (with cable gland)
II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
4211
–
5,3
–
23
IP66 (with cable gland)
II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
4610
3,9
–
162
–
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
1/2 NPT *2)
4611
–
5,3
–
23
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
1/2 NPT *2)
4612
3,9
–
162
–
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
4613
–
5,3
–
23
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *2) Connector cable gland not supplied see table, "Accessories". Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals 32
Model
Approvals ATEX
IECEx FM
42xx
KEMA 98 ATEX 4452 X
IECEx KEM 09.0068X
46xx
PTB 02 ATEX 2085 X
IECEx PTB 11.0094X
For further information www.imi-precision.com
Accessories Cable gland Protection Ex e, Ex d (ATEX)
Model
For solenoid
Thread
Cable Ø (mm)
Material
Protection class (ATEX)
Ambient temperature limitation
0589735
42xx
M20 x 1,5
7,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *3)
0589736
42xx
M20 x 1,5
10,0 … 14,0
Plastic
II 2G Ex e / II 2D Ex t
See table *3)
0589737
42xx
M20 x 1,5
6,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *3)
0588819
46xx
M20 x 1,5
5,0 … 8,0
Nickel plated brass
II 2G Ex e / II 2D Ex t
–
0588851
46xx
M20 x 1,5
10,0 … 14,0
Nickel plated brass
II 2G Ex d / II 2D Ex t
–
0588925
46xx
1/2 NPT
7,5 … 11,9
Nickel plated brass
II 2G Ex d / II 2D Ex t
–
*3) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.
For solenoid
421x/426x
Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *4)
0589737
T4 & Dust Ex: -35°C … + 80°C
T4 & Dust Ex: -40°C … + 65°C
T6: -35°C … + 55°C
T6: -40°C … + 55°C
*4) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.
Connector DIN EN 175301-803
0570275, Form A *5) For indoors use only. *6) For outdoors use ~ 0,2 (bar).
Silencer (plastic) *5)
Silencer (stainless steel) *5)
Exhaust guard *6)
M/S2 (G1/4)
0014613 (G1/4)
0613422 (1/4")
M/S4 (G1/2)
0613678 (1/4 NPT)
0613423 (1/2")
98025 NAMUR & Inline • G1/4, 1/4 NPT, G1/2, 1/2 NPT & NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Technical features Medium: non-lubricated and dried compressed air, instrument air, nitrogen and other nonflammable neutral, dry fluids Operating pressure: 2 … 8 bar (29 … 116 psi) 0 … 8 bar (0 … 116 psi) with external air supply Fluid/Ambient temperature: -40°C … +60°C (-40°F … +140°F) SIL-Version: -25°C … +60°C (-13°F … +140°F) Depending on solenoid system.
VALVES
• 3/2 poppet valves electromagnetic actuated, indirectly controlled
1
Suited for outdoor use under critical environment conditions Materials: Housing: Aluminium 3.0615 Seal: NBR Inner parts: stainless steel
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Approved
SIL2 @ HFT=0 SIL3 @ HFT=1
Approval depends on magnetic system
Technical data Symbol 2 3
3
Port size 1, 3
2 (3)
Flow (l/min) *2) 1 » 2 2»3
Flow (l/min) *3) 1 » 2 2»3
Material
Test certificate IEC 61508
9802505
G1/4, G1/2
NAMUR G1/4
1250
1500
2500
3100
Aluminium
x
NAMUR 1/4 NPT
1250
1500
2500
3100
Aluminium
x
G1/2
1300
1200
2700
2600
Aluminium
x
1/2 NPT
1300
1200
2700
2600
Aluminium
x
9802515 1/4 NPT, 1/2 NPT V-AE-32C-EM-F 1 2 3
3
9802555
2
G1/2
V-32C-EM-F
11
3
9802565 1/2 NPT V-AE-32C-EMH-F
1
Solenoids
3
1
*1) When ordering, please indicate solenoid, voltage and current (frequency). *2) Inlet pressure 6 bar, outlet pressure 5 bar. *3) Inlet pressure 8 bar, outlet pressure 0 bar.
V-AE-32C-EMR-F
2 Model
1
3
V-32C-EMR-F Power consumption
Rated current
IP-Protection Ex-Protection (ATEX-Category)
Temperature Ambient/ Medium (°C)
Electrical connection
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
0763
1,9
2,1 *4)
78
11
IP65 (with Connector)
–
-25 … +60
DIN EN 175 301-803 Form A *5)
4200
0,8
–
38
–
IP66 (with cable gland)
II 2G Ex eb mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
M20 x 1,5 *5)
4201
–
1,3
–
6
IP66 (with cable gland)
II 2G Ex eb mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
M20 x 1,5 *5)
4600
0,8
–
33
–
IP66 (with cable gland)
II 2G Ex d mb IIC T5/T6 Gb II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
1/2 NPT *5)
4601
–
1,3
–
6
IP66 (with cable gland)
II 2G Ex d mb IIC T5/T6 Gb II 2G Ex e mb IIC T5/T6 Gb II 2D Ex tb IIIC T130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
1/2 NPT *5)
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *4) Required connector: model 0570275 for V DC; model 0663303 for V AC, to be ordered Solenoid Voltage 200V DC! *5) Connector cable gland not supplied, see table »Accessories«. Attention: The protection class for coil series 46xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals Model
Approvals ATEX IECEx
42xx
KEMA 98 ATEX 4452 X
IECEx KEM 09.0068X
46xx
PTB 02 ATEX 2085 X
IECEx PTB 11.0094X
For further information www.imi-precision.com
2 3 to ISO 3 6358 and ISO 8778, 20°C In order to ensure full flow and proper Flow conducted according 2 function make sure that sufficient pressure supply with feed pipe diameters according to the port size is available. V-32C-EMH-F
33
Model *1)
1
98025 NAMUR & Inline
VALVES
Accessories Cable gland Protection Ex e, Ex d (ATEX)
Model
For solenoid
Thread
Cable Ø (mm)
Material
Protection class (ATEX)
Ambient temperature limitation
0589735
42xx
M20 x 1,5
7,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *6)
0589736
42xx
M20 x 1,5
10,0 … 14,0
Plastic
II 2G Ex e / II 2D Ex t
See table *6)
0589737
42xx
M20 x 1,5
6,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *6)
0588819
46xx
M20 x 1,5
5,0 … 8,0
Nickel plated brass
II 2G Ex e / II 2D Ex t
–
0588851
46xx
M20 x 1,5
10,0 … 14,0
Nickel plated brass
II 2G Ex d / II 2D Ex t
–
0588925
46xx
1/2 NPT
7,5 … 11,9
Nickel plated brass
II 2G Ex d / II 2D Ex t
–
*6) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.
For solenoid
420x/425x
Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *7)
0589737
T5 & Dust Ex: -35°C … + 80°C
T5 & Dust Ex: -40°C … +68°C
T6: -35°C … +70°C
T6: -40°C … +68°C
*7) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.
Silencer (plastic) *8)
Exhaust guard *9)
Add-on manual override
Add-on manual override (for start-up only)
0570275, Form A
M/S2 (G1/4)
0613422 (1/4")
0553886 (without detent)
0613379 (without detent)
0613423 (1/2")
0553887 (with detent, return at pressure failure)
34
Connector DIN EN 175301-803
For further information www.imi-precision.com
0663303 Form A (with rectifier)
C/S2 (1/4 NPT) M/S4 (G1/2) C/S4 (1/2 NPT)
*8) For indoors use only. *9) For outdoors use ~ 0,2 (bar). *10) Use function descrption 75036430.
0614084 (with detent) *10)
6215M NAMUR & Inline
Suited for outdoor use under critical environment conditions
Technical features
• Indirect solenoid actuated spool valve
Medium: Filtered, non-lubricated or lubricated and dried compressed air Operating pressure: 2,5 … 8 bar (36 … 116 psi) with internal air supply Orifice: 6 mm (1/4”) Ambient/Media temperature: -40°C … +60°C (-40°F … +140°F)
• 3/2 & 5/2
Material: Body: Aluminum with surface treatment for critical environmental conditions Seals: Special NBR
VALVES
ATEX, IECEx, NEPSI
• G1/4, 1/4 NPT or NAMUR Interface
1
Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below +2°C For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP65 protection must be used!
Technical data
Symbol
1
3
2 4 2 10 12
12 14
1 3 51 3 2 10 4 2 12 1 3 51 3
Port size
Orifice (mm)
Function
Actuation/return
Flow (l/min)
Operating pressure (bar)
Weight (kg)
6215M3530 2
G1/4
6
3/2
Solenoid/spring
1200
2,5 … 8
0,392
6215M3540
1/4 NPT
6
3/2
Solenoid/spring
1200
2,5 … 8
0,392
6
5/2
Solenoid/spring
1200
2,5 … 8
0,442
6
5/2
Solenoid/spring
1200
2,5 … 8
0,442
1
12
3
10 4 2 12
14
1
3
51 3 2 10 G1/4 126215M0530 2 12 4 14
6215M0540 1 3
51 3
1/4 NPT
*1) When ordering please type (frequency). 2 12 4 2indicate 14 12 solenoid, voltage 14 and 4current 51 3
51 3
3/2 and 5/2 way valves NAMUR Housing: Aluminium anodized, Seals: NBR -40°C … +60°C (-40°F … +140°F) 4 2 10 14 52_Namur-EM-F Model *1)
Symbol 5 13 14
44 22 12 10
6215M0500
Ports 1, 3, 5
2, 4
Orifice (mm)
Actuation/return
Flow (l/min)
Operating pressure (bar)
Weight (kg)
G1/4
Flange
6
Solenoid/spring
1200
2,5 … 8
0,48
1/4 NPT
Flange
6
Solenoid/spring
1200
2,5 … 8
0,48
52_Namur-EMH-F 14 14
14
551 13 3 44 22 12 10
6215M0510 52_Namur-EMR-F
551 13 3
*1) When ordering please 4 2indicate 12 solenoid, voltage and current type (frequency). Valve function: 3/2 or 5/2 way function. 14
51 3
For further information www.imi-precision.com
12 14
Model *1)
35
3/2 and 5/2 way valves Inline Housing: anodized, 2 10 2 10Seals: NBR -40°C … +60°C (-40°F … +140°F) 12 Aluminium 12
1
6215M NAMUR & Inline
VALVES
Solenoids group 13B, standard voltages Model
36
Power consumption
Rated current
Protection class
Ex-Protection (ATEX-Category) Temperature Ambient/Media
Electrical connection
Weight
24 V d.c. (W)
230 V a.c. (VA)
24 V d.c. (mA)
230 V a.c. IP/NEMA (mA)
4210
3,9
–
162
–
IP66 (with cable gland)
II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db IP66
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
0,5
4211
–
5,3
–
23
IP66 (with cable gland)
II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db IP66
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
0,5
4610
3,9
–
162
–
IP66 (with cable gland)
II 2 G Ex d mb IIC T4/T6 Gb II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
1/2 NPT *2)
0,8
4611
–
5,3
–
23
IP66 (with cable gland)
II 2 G Ex d mb IIC T4/T6 Gb II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
1/2 NPT *2)
0,8
4612
3,9
–
162
–
IP66 (with cable gland)
II 2 G Ex d mb IIC T4/T6 Gb II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
0,8
4613
–
5,3
–
23
IP66 (with cable gland)
II 2 G Ex d mb IIC T4/T6 Gb II 2 G Ex e mb IIC T4/T6 Gb II 2 D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
0,8
3722
5,5
–
228
–
NEMA 4, 4X, 6, 6P, 7, 9
XP/DIP, Div. 1 & 2 CI. I, Gr. A-D CI. II/III, Gr. E-G T3 (160°C)
-20 … +60
Flying leads 450 mm
0,5
3723
–
5,9
–
26
NEMA 4, 4X, 6, 6P, 7, 9
XP/DIP, Div. 1 & 2 CI. I, Gr. A-D CI. II/III, Gr. E-G T3 (160°C)
-20 … +60
Flying leads 450 mm
0,5
(°C)
(kg)
For further information www.imi-precision.com
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *2) Connector/cable gland is not scope of delivery, see table »Accessories«. Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Accessories Electrical connection Cable gland Protection class Ex e, Ex d
Model
Approvals Thread
Cable Ø (mm)
Materials
Protection class (ATEX)
Model
42xx
KEMA 98 ATEX 4452 X
IECEx KEM 09.0068X –
46xx
PTB 02 ATEX 2085 X
IECEx PTB 11.0094X
588819
M20 x 1,5
5…8
Nickel plated brass
II 2 GD Ex e
588851
M20 x 1,5
10 … 14
Nickel plated brass
II 2 GD Ex d
588925
1/2 NPT
7,5 … 11,9 Nickel plated brass
II 2 GD Ex d
589385
M20 x 1,5
9 … 13
Stainless steel 1.4571 (316 Ti)
II 2 GD Ex e
589395
M20 x 1,5
7 … 12
Stainless steel 1.4404 (316 L)
II 2 GD Ex d
589387
M20 x 1,5
10 … 14
Stainless steel 1.4404 (316 L)
II 2 GD Ex d
Approvals ATEX
372x, 382x –
IECEx
FM
–
CSA-LR 57643-6 –
Valve Adaptor complete (Adaptor, inlet filter and seal ring)
Inlet filter
Silencer (plastic) *3)
Silencer (stainless steel) *3)
Silencer (brass) *3)
Exhaust guard *4)
Conversion plate
0613487 (G1/4)
0681173 (G1/4, 1/4 NPT)
M/S2 (G1/4)
0014613 (G 1/4)
T40C2800 (G 1/4)
0613422 (G1/4, 1/4 NPT)
A1502-Z11
C/S2 (1/4 NPT)
0613678 (1/4 NPT)
MS002A (1/4 NPT)
*3) For indoors use only. *4) For outdoors use, opening pressure ~ 0,2 bar.
6215L NAMUR & Inline Technical features
• Indirect solenoid actuated spool valve
Medium: Filtered, non-lubricated and dried compressed air Operating pressure: 2,5 … 8 bar (36 … 116 psi) with internal air supply Ambient/Media temperature: -40°C … +60°C (-40°F … +140°F)
• 3/2 & 5/2
Suited for outdoor use under critical environment conditions ATEX, IECEx, NEPSI
Material: Body: Aluminum with surface treatment for critical environmental conditions Seals: Special NBR
VALVES
• G1/4, 1/4 NPT or NAMUR Interface
1
Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below +2°C For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP65 protection must be used!
Technical data
Symbol
1
3
2 4 2 10 12
12 14
1 3 51 3 2 10 4 2 12 1 3 51 3
Port size
Function
Actuation/return
Flow (l/min)
Operating pressure (bar)
Weight (kg)
6215L3530 2
G1/4
03/2
Solenoid/spring
1200
2,5 … 8
0,392
6215L3540
1/4 NPT
03/2
Solenoid/spring
1200
2,5 … 8
0,392
5/2
Solenoid/spring
1200
2,5 … 8
0,442
5/2
Solenoid/spring
1200
2,5 … 8
0,442
Actuation/return
Flow (l/min)
Operating pressure (bar)
Weight (kg)
1
12
3
10 4 2 12
14
1
3
51 3 2 10 G1/4 126215L0530 2 12 4 14
6215L0540 1 3
51 3
1/4 NPT
*1) When ordering please type (frequency). 2 12 4 2indicate 14 12 solenoid, voltage 14 and 4current 51 3
51 3
3/2 and 5/2 way valves NAMUR Housing: Aluminium anodized, Seals: NBR -40°C … +60°C (-40°F … +140°F) 4 2 10 14 Symbol
52_Namur-EM-F Model *1)
Ports 1, 3, 5
2, 4
6215L0500
G1/4
Flange
Solenoid/spring
900
2,5 … 8
0,48
1/4 NPT
Flange
Solenoid/spring
900
2,5 … 8
0,48
5 13 14
44 22 12 10
52_Namur-EMH-F 14 14
14
551 13 3 44 22 12 10
6215L0510 52_Namur-EMR-F
551 13 3
*1) When ordering please 4 2indicate 12 solenoid, voltage and current type (frequency). Valve function: 3/2 or 5/2 way function. 14
51 3
For further information www.imi-precision.com
12 14
Model *1)
37
3/2 and 5/2 way valves Inline Housing: anodized, 2 10 2 10Seals: NBR -40°C … +60°C (-40°F … +140°F) 12 Aluminium 12
1
6215L NAMUR & Inline
VALVES
Solenoids group, standard voltages Model
Power consumption
Rated current
Protection class
Ex-Protection (ATEX-Category) Temperature Ambient/Media
Electrical connection
Weight
24 V d.c. (W)
230 V a.c. (VA)
24 V d.c. (mA)
230 V a.c. IP/NEMA (mA)
4200
0,8
–
33
–
IP 66
II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
M20 x 1,5 *2)
0,6
4201
–
1,3
–
6
IP 65
II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
0,6
4600
0,8
–
33
–
IP 66
II2G Ex d mb IIC T5/T6 Gb II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
1/2 NPT *2)
0,8
4602
0,8
–
33
–
IP 66
II2G Ex d mb IIC T5/T6 Gb II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
M20 x 1,5 *2)
0,8
4601
–
1,3
–
6
IP 66
II2G Ex d mb IIC T5/T6 Gb II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
1/2 NPT *2)
0,8
4603
–
1,3
–
6
IP 66
II2G Ex d mb IIC T5/T6 Gb II2G Ex e mb IIC T5/T6 Gb II2D Ex tb IIICT130°C Db
T5: -40 … +80 T6: -40 … +70 -40 … +80
M20 x 1,5 *2)
0,8
3720
1,4
–
59
–
4, 4X, 6, 6P, 7, 9
II2G Ex mb d IIC T4/T6 II2G EX mb e II T4/T6 II 2 D Ex td a21
-20 … +60
Flying leads 450 mm
0,4
(°C)
(kg)
38
For further information www.imi-precision.com
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *2) Connector/cable gland is not scope of delivery, see table »Accessories« Attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Accessories Electrical connection Cable gland Protection class Ex e, Ex d
Model
Approvals Thread
Cable Ø (mm)
Materials
Protection class (ATEX)
Model
42xx
KEMA 98 ATEX 4452 X IECEx KEM 09.0068X –
46xx
PTB 02 ATEX 2085 X
588819
M20 x 1,5
5…8
Nickel plated brass
II 2 GD Ex e
588851
M20 x 1,5
10 … 14
Nickel plated brass
II 2 GD Ex d
588925
1/2 NPT
7,5 … 11,9 Nickel plated brass
II 2 GD Ex d
589385
M20 x 1,5
9 … 13
Stainless steel 1.4571 (316 Ti)
II 2 GD Ex e
589395
M20 x 1,5
7 … 12
Stainless steel 1.4404 (316 L)
II 2 GD Ex d
589387
M20 x 1,5
10 … 14
Stainless steel 1.4404 (316 L)
II 2 GD Ex d
Approvals ATEX
372x, 382x –
IECEx
FM
–
CSA-LR 57643-6
IECEx PTB 11.0094X
–
Valve Adaptor complete (Adaptor, inlet filter and seal ring)
Inlet filter
Silencer (plastic) *3)
Silencer (stainless steel) *3)
Silencer (brass) *3)
Exhaust guard *4)
Conversion plate
0613487 (G1/4)
0681173 (G1/4, 1/4 NPT)
M/S2 (G1/4)
0014613 (G1/4)
T40C2800 (G1/4)
0613422 (G1/4, 1/4 NPT)
A1502-Z11
C/S2 (1/4 NPT)
0613678 (1/4 NPT)
MS002A (1/4 NPT)
*3) For indoors use only. *4) For outdoors use, opening pressure ~ 0,2 bar.
24011 NAMUR & Inline • G1/4, 1/4 NPT, flanged with NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Technical features Medium: Compressed, air filtered, non-lubricated and dry. Other gase and liquid fluids on request Operating pressure: 0 … 10 bar (0 … 145 psi) Flow: 340l/min Fluid/Ambient temperature: -25°C … +80°C (-13°F … +176°F) (NBR) -10°C … +120°C (+14°F … -248°F) (FKM)
1 VALVES
• 3/2 poppet valves electromagnetic actuated, directly controlled
Suited for outdoor use under critical environment conditions Water: +95°C (+ 203°F) -40°C … +60°C (-40°F … +140°F) (VMQ)Depending on solenoid system. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing: stainless steel 1.4404 (316L), brass 2.0402 (Ms 58), anodized aluminium Seal: FKM, NBR, VMQ Inner parts: stainless steel, brass
SIL2 @ HFT=0 SIL3 @ HFT=1
Approved
Approval depends on magnetic system
Technical data Housing: Brass Symbol
2
Solenoidgroup
Port size
Seal
Manual override
Test certificate IEC 61 508
2401103
A+B
G1/4
NBR
Not possible
X
–
2401149
A+B
G1/4
NBR
Not possible
X
X
2401138
A+B
1/4 NPT
NBR
Not possible
X
X
2014/68/EU
39
1 3
Model *1)
*1) When ordering, please indicate solenoid, voltage and current (frequency).
Housing: Stainless steel (1.4404)
2
Model *1)
Solenoidgroup
Port size
Seal
Manual override
Test certificate IEC 61 508
2401127
A
G1/4
FKM
Not possible
–
–
2401147
A
1/4 NPT
FKM
Not possible
–
–
2401196
A+B
G1/4
NBR
Upgradeable
X
–
1025212 *2)
A+B
G1/4
NBR
Upgradeable
X
X
1025328 *2)
A+B
1/4 NPT
NBR
Upgradeable
X
X
2014/68/EU
1 3 3 2 12
3 1
2
3 2 12
3 11
2
*1) When ordering, please indicate solenoid, voltage and current (frequency). *2) Acc. to VDI/VDE 3845 port 1 in flange for attachment of positioners or to interlinking plate (see data sheet N/en 5.8.300).
Housing: Anodized aluminium Symbol 3 2
Model *1)
Solenoidgroup
Port size
Seal
Manual override
Test certificate IEC 61 508
2401191
A+B
G1/4
NBR
Upgradeable
X
X
1025254
A+B
1/4 NPT
NBR
Upgradeable
X
X
2401109 *2)
A+B
G1/4
NBR
Upgradeable
X
X
2014/68/EU
12
3 1
2
3 2 12
3 11
2
*1) When ordering, please indicate solenoid, voltage and current (frequency). *2) Acc. to VDI/VDE 3845 port 1 in flange for attachment of positioners or to interlinking plate (see data sheet N/en 5.8.300).
For further information www.imi-precision.com
Symbol
1
24011 NAMUR & Inline
VALVES
Solenoid operator, solenoid group A Model
Power consumption
Rated current
40
For further information www.imi-precision.com
IP-Protection/ Ex-Protection NEMA (ATEX-Category)
Temperature Ambient/ Medium (°C)
Electrical connection
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
0800
16,9
–
703
–
IP65 (with Connector)
–
-25 … +60 Fluid: max. +80
Connector DIN EN 175301-803 Form A *3)
3803
–
19,5
–
75
IP65 (with Connector)
–
-25 … +60 Fluid: max. +80
Connector DIN EN 175301-803 Form A *3)
4270
8,9
–
369
–
IP66 (with cable gland)
II 2G Ex eb mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +65 T5: -40 … +55 -40 … +65
M20 x 1,5 *3)
4271
–
10,0
–
43
IP66 (with cable gland)
II 2G Ex eb mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +65 T5: -40 … +55 -40 … +65
M20 x 1,5 *3)
4670
8,9
–
369
–
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 T6: -40 … +40 -40 … +70
1/2 NPT *3)
4671
–
10,0
–
43
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 T6: -40 … +40 -40 … +70
1/2 NPT *3)
4672
8,9
–
369
–
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 T6: -40 … +40 -40 … +70
M20 x 1,5 *3)
4673
–
10,0
–
43
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 T6: -40 … +40 -40 … +70
M20 x 1,5 *3)
4872
8,9
–
369
–
IP66 (with cable gland)
II 2G Ex mb d IIC T4/T6 Gb II 2G Ex mb e IIC T4/T6 Gb
T4: -40 … +50 T6: -40 … +40
M20 x 1,5 *3)
4873
–
10
–
43
IP66 (with cable gland)
II 2G Ex mb d IIC T4/T6 Gb II 2G Ex mb e IIC T4/T6 Gb
T4: -40 … +50 T6: -40 … +40
M20 x 1,5 *3)
3826
13,6
–
567
–
4x
Cl. I, Div. 1, Gr. A - D Cl. II/III, Div. 1, Gr. E - G T3C (160°C)
-20 … +60
Flying leads length 460 mm
3827
–
15,7
–
68
4x
Cl. I, Div. 1, Gr. A - D Cl. II/III, Div. 1, Gr. E - G T3C (160°C)
-20 … +60
Flying leads length 460 mm
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *3) Connector cable gland not supplied, see table »Accessories« Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals Model
Approvals ATEX IECEx FM
382x
–
–
CSA-LR 57643-6
42xx
KEMA 98 ATEX 4452 X
IECEx KEM 09.0068X
–
46xx
PTB 02 ATEX 2085 X
IECEx PTB 11.0094X
–
48xx
PTB 06 ATEX 2054 X
IECEx PTB 07.0039X
–
24011 NAMUR & Inline
1
Model
Power consumption
Rated current
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
0827
6,8
–
284
3805
–
10,6
4260
3,9
4261
Electrical connection
–
IP65 (with Connector)
–
-25 … +60
Connector DIN EN 175301-803 Form A *3)
–
46
IP65 (with Connector)
–
-25 … +60
Connector DIN EN 175301-803 Form A *3)
–
162
–
IP66 (with cable gland)
II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *3)
–
5,3
–
23
IP66 (with cable gland)
II 2G Ex eb mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *3)
4660
3,9
–
162
–
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
1/2 NPT *3)
4661
–
5,3
–
23
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
1/2 NPT *3)
4662
3,9
–
162
–
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *3)
4663
–
5,3
–
23
IP66 (with cable gland)
II 2G Ex d mb IIC T4/T6 Gb II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *3)
3824
8,9
–
369
–
4x
Cl. I, Div. 1, Gr. A - D Cl. II/III, Div. 1, Gr. E - G T3C (160°C)
-20 … +60
Flying leads length 460 mm
3825
–
9,5
–
41
4x
Cl. I, Div. 1, Gr. A - D Cl. II/III, Div. 1, Gr. E - G T3C (160°C)
-20 … +60
Flying leads length 460 mm
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle. *3) Connector cable gland not supplied, see table »Accessories« Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals Model
Approvals ATEX IECEx FM
382x
–
–
CSA-LR 57643-6
42xx
KEMA 98 ATEX 4452 X
IECEx KEM 09.0068X
–
46xx
PTB 02 ATEX 2085 X
IECEx PTB 11.0094X
–
For further information www.imi-precision.com
Temperature Ambient/ Medium (°C)
41
IP-Protection/ Ex-Protection NEMA (ATEX-Category)
VALVES
Solenoid operator, solenoid group B
1
24011 NAMUR & Inline
VALVES
Accessories Cable gland Protection Ex e, Ex d (ATEX)
Model
For solenoid
Thread
Cable Ø (mm)
Material
Protection class (ATEX)
Ambient temperature limitation
0589735
42xx
M20 x 1,5
7,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *4)
0589736
42xx
M20 x 1,5
10,0 … 14,0
Plastic
II 2G Ex e / II 2D Ex t
See table *4)
0589737
42xx
M20 x 1,5
6,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *4)
0588819
46xx
M20 x 1,5
5,0 … 8,0
Nickel plated brass
II 2G Ex e / II 2D Ex t
–
0588851
46xx
M20 x 1,5
10,0 … 14,0
Nickel plated brass
II 2G Ex d / II 2D Ex t
–
0588925
46xx
1/2 NPT
7,5 … 11,9
Nickel plated brass
II 2G Ex d / II 2D Ex t
–
0589385
46xx, 48xx
M20 x 1,5
9,0 … 13,0
Stainless steel 1.4571
II 2G Ex e / II 2D Ex t
–
0589395
46xx, 48xx
M20 x 1,5
7,0 … 12,0
Stainless steel 1.4404
II 2G Ex d / II 2D Ex t
–
0589387
46xx, 48xx
M20 x 1,5
10,0 … 14,0
Stainless steel 1.4404
II 2G Ex d / II 2D Ex t
–
*4) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.
For solenoid
421x/426x 422x/427x
Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *5)
0589737
T4 & Dust Ex: -35°C … + 80°C
T4 & Dust Ex: -40°C … + 65°C
T6: -35°C … + 55°C
T6: -40°C … + 55°C
T4 & Dust Ex: -35°C … +65°C
T4 & Dust Ex: -40°C … + 62°C
T5: -35°C … + 55°C
T5: -40°C … + 55°C
*5) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.
42 Connector DIN EN 175301-803
For further information www.imi-precision.com
0570275, Form A *6) For indoors use only *7) For outdoors, use ~ 0,2 (bar)
Silencer (plastic) *6)
Silencer (stainless steel) *6)
Exhaust guard *7)
Add-on manual override
Add-on manual override
C/S2 1/4 NPT
0014613 (G1/4)
0613422 (1/4")
0601765 (with detent)
0600205 (without detent)
M/S2 G1/4
0613678 (1/4 NPT)
24010 NAMUR & Inline • G1/4, 1/4 NPT, flanged with NAMUR interface The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Solenoid valves with low Power consumption
Technical features Medium: Compressed air, filtered, non-lubricated and dry. Other fluids on request. Operating pressure: 0 … 10 bar (0 … 145 psi) Flow: 340 I/min Fluid/Ambient temperature: -25°C … +60°C (-13°F … +140°F) Depending on solenoid system
VALVES
• 3/2 poppet valves electromagnetic actuated, directly controlled
1
High operational reliability even after long periods of non-operation
For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing: brass 2.0402 (Ms 58), stainless steel 1.4404 (316L), hard anodized aluminium 3.0615 Seal: Stainless steel, Brass Solenoid housing: Aluminium 3.0615, hard anodised Seals: NBR
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
SIL2 @ HFT=0 SIL3 @ HFT=1
DIN EN 61508 IEC 61508 Approval depends on magnetic system
Technical data Symbol
Model
Port size
Operating pressure (bar)
Manual Override
Seal:
2401088200300000
G1/4
0 … 10
Not Possible
NBR
Brass
2401087200300000
1/4 NPT
0 … 10
Not Possible
NBR
Brass
2401086200300000
G1/4
0 … 10
Not Possible
NBR
Stainless steel
1 3
2401012200300000
1/4 NPT
0 … 10
Not Possible
NBR
Stainless steel
3 2
2401091200300000
G1/4 NAMUR
0 … 10
Upgradeable
NBR
Aluminium
2401090200300000
1/4 NPT NAMUR
0 … 10
Upgradeable
NBR
Aluminium
2
Housing
12
3 1
2
Solenoid parameters for use in non harardous locations Switch-on voltage
Current consumption
Power consumption
Pick-up delay typical *1)
(V)
(mA)
(W)
(s)
2003
22 … 26,4
< 75
1,8 at 24 V
0,3 … 2
Ex-Protection (ATEX-Category)
Temperature Ambient/Fluid
Weight
(°C)
(kg)
IP66 with cable gland (cable Ø 5 … 10 mm) is in scope of delivery
–
-40 … +80
0,85
IP-Protection
Ex-Protection (ATEX-Category)
Temperature Ambient/Fluid
Weight
(°C)
(kg)
IP66 with cable gland (cable Ø 5 … 10 mm) is in scope of delivery
II 2G Ex ia IIC T5/T6 II 2D Ex tD IP66 T95°C
T5: -40 … +70 T6: -40 … +55 -40 … +70
0,85
*1) depending on intrinsical current supply.
Solenoid parameters for use in intrinsically safe circuits Symbol
Model
Switch-on voltage (V)
2003
22 … 28
Holding current
Holding voltage
(mA)
(V)
> 40
~5
Pick-up delay typical *1) (s) 0,3 … 5
*1) depending on intrinsical current supply.
Operating sequence
Approvals
U (V)
Model
Approvals ATEX IECEx
28
2003
PTB 04 ATEX 2010
22
IECEx PTB 05.0020
1
Accessories Silencer (plastic) *2)
Silencer (stainless steel) *2)
2
Exhaust guard *3) 0
t I (mA)
75 60 40 20 0
M/S2 (G1/4)
0014613 (G1/4)
C/S2 (1/4 NPT)
0613678 (1/4 NPT)
0613422 (1/4")
3 t 1 Supply voltage 2 Capacitor charging voltage
ON
*2) For indoors use only. *3) For outdoors use ~ 0,2 (bar).
3 Solenoid current
4 OF
t
4 Valve status
For further information www.imi-precision.com
Standard voltages (±10%), Design according to VDE 0580, EN 50014/50028. 100% duty cycle. Pick-up delay typical: 0,3 … 2 s, depending on intrinsical current supply.
IP-Protection
43
Model
1
98015 NAMUR & Inline
VALVES
• 3/2- & 5/2-Spool valves electromagnetic actuated, indirectly controlled
Suited for outdoor use under critical environment conditions
Technical features Medium: Filtered, non-lubricated and dried compressed Air Operating pressure: 0 … 10 bar (0 … 145 psi) Flow: see Tabelle Fluid/Ambient temperature: -40°C … +60°C (-40°F … +140°F) (NBR) -25°C … +60°C (-13°F … +140°F) (SIL version) Depending on solenoid system
• G1/4, G1/2
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing: stainless steel 1.4404 (316L), brass, aluminium anodized Seal: NBR Inner parts: stainless steel or brass Approved
SIL2 @ HFT=0 SIL3 @ HFT=1
Approval depends on magnetic system
Technical data Symbol
2
1
3
3 2
44
1
3
Model *1)
Port size 1, 3
2 (3)
Flow (l/min) *2) 1 » 2 2 » 3
Flow (l/min) *3) 1 » 2 2 » 3
Operating pressure (bar)
Material
Manual overrideSolenoids
Test certificate IEC 61 508
9801505
G1/4, G1/2
NAMUR, G1/4
1100
1300
2900
3400
0 … 10
Aluminium
Upgradeable
x
9801515 1/4 NPT, 1/2 NPT NAMUR, 1/4 NPT 1100 V-AE-32C-E-S
1300
2900
3400
0 … 10
Aluminium
Upgradeable
x
9801755
G1/2
1200
1300
3100
3400
0 … 10
Stainless steel
Upgradeable
x
9801765 1/2 NPT V-32C-all-E-F 9801655 G1/2
G1/2
1/2-NPT
1200
1300
3100
3400
0 … 10
Stainless steel
Upgradeable
x
G1/2
1200
1300
3100
3400
0 … 10
Brass
Upgradeable
x
9801665
1/2-NPT
1200
1300
3100
3400
0 … 10
Brass
Upgradeable
x
1/2 NPT
*1) When ordering 2please indicate solenoid, voltage and current type (frequency). *2) Inlet pressure 6 bar, outlet pressure 5 bar.
*3) Inlet pressure 10 bar, Outlet pressure 0 Bar.
V-32C-all-EH-F
Solenoids1
3
For further information www.imi-precision.com
2 1
3
Model Power Rated current IPV-32C-all-ER-F consumption Protection 24 V DC 230 V AC 24 V DC 230 V AC (W) (VA) (mA) (mA)
Ex-Protection (ATEX-Category)
Ambient Temperature Medium (°C)
Electrical connection
0800
16,9
–
703
–
IP65 (with Connector)
–
-25 … +60 Fluid: max. 80
Connector DIN EN 175301-803 Form A *4)
3803
–
17,3
–
75
IP65 (with Connector)
–
-25 … +60 Fluid: max. 80
Connector DIN EN 175301-803 Form A *4)
4270
8,9
–
369
–
IP66 (with II 2G Ex eb mb IIC T4/T5 Gb T4: -40 … +65 M20 x 1,5 *4) cable gland) II 2D Ex tb IIIC T130°C Db T5: -40 … +55 -40 … +65
4271
–
10,0
–
43
IP66 (with II 2G Ex eb mb IIC T4/T5 Gb T4: -40 … +65 M20 x 1,5 *4) cable gland) II 2D Ex tb IIIC T130°C Db T5: -40 … +55 -40 … +65
4670
8,9
–
369
–
IP66 (with II 2G Ex d mb IIC T4/T6 Gb cable gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 1/2 NPT *4) T6: -40 … +40 -40 … +70
4671
–
10,0
–
43
IP66 (with II 2G Ex d mb IIC T4/T6 Gb cable gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 1/2 NPT *4) T6: -40 … +40 -40 … +70
4672
8,9
–
369
–
IP66 (with II 2G Ex d mb IIC T4/T6 Gb cable gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 M20 x 1,5 *4) T6: -40 … +40 -40 … +70
4673
–
10,0
–
43
IP66 (with II 2G Ex d mb IIC T4/T6 Gb cable gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 M20 x 1,5 *4) T6: -40 … +40 -40 … +70
4872
8,9
–
369
–
IP66 (with II 2G Ex mb d IIC T4/T6 Gb T4: -40 … +50 M20 x 1,5 *4) cable gland) II 2G Ex mb e IIC T4/T6 Gb T6: -40 … +40
42xx
KEMA 98 IECEx KEM ATEX 4452 X 09.0068X
IP66 (with II 2G Ex mb d IIC T4/T6 Gb T4: -40 … +50 M20 x 1,5 *4) cable gland) II 2G Ex mb e IIC T4/T6 Gb T6: -40 … +40
46xx
IECEx PTB PTB 02 ATEX 2085 X 11.0094X
4873
–
10,0
–
43
Approvals Model Approvals ATEX IECEx
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED. *4) Connectors/Cable gland is not included, see accessories. Attention: The protection class for coil series 46xx or 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
98015 NAMUR & Inline
1
Cable gland Protection Ex e, Ex d (ATEX)
Model
For solenoid
Thread
Cable Ø (mm)
Material
Protection class (ATEX)
Ambient temperature limitation
0589735
42xx
M20 x 1,5
7,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *5)
0589736
42xx
M20 x 1,5
10,0 … 14,0
Plastic
II 2G Ex e / II 2D Ex t
See table *5)
0589737
42xx
M20 x 1,5
6,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *5)
0588819
46xx
M20 x 1,5
5,0 … 8,0
Nickel plated brass
II 2G Ex e / II 2D Ex t
–
0588851
46xx
M20 x 1,5
10,0 … 14,0
Nickel plated brass
II 2G Ex d / II 2D Ex t
–
0588925
46xx
1/2 NPT
7,5 … 11,9
Nickel plated brass
II 2G Ex d / II 2D Ex t
–
0589385
46xx, 48xx
M20 x 1,5
9,0 … 13,0
Stainless steel 1.4571
II 2G Ex e / II 2D Ex t
–
0589395
46xx, 48xx
M20 x 1,5
7,0 … 12,0
Stainless steel 1.4404
II 2G Ex d / II 2D Ex t
–
0589387
46xx, 48xx
M20 x 1,5
10,0 … 14,0
Stainless steel 1.4404
II 2G Ex d / II 2D Ex t
–
VALVES
Accessories
*5) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.
For solenoid
422x/427x
Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *6)
0589737
T4 & Dust Ex: -35°C … +65°C
T4 & Dust Ex: -40°C … +62°C
T5: -35°C … +55°C
T5: -40°C … +55°C
*6) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.
Silencer (stainless steel) *7)
Exhaust guard *8)
Add-on manual override
Add-on manual override
0570275, Form A
C/S2 (1/4 NPT)
0014613 (G1/4)
0613422 (1/4")
0601765 (with detent)
0600205 (without detent)
M/S2 (G1/4)
0613678 (1/4 NPT)
0613423 (1/2")
C/S4 (1/2 NPT)
0014813 (G1/2)
M/S4 (G1/2)
0613679 (1/2 NPT)
*7) For indoors use only. *8) For outdoors, use ~ 0,2 (bar).
For further information www.imi-precision.com
Silencer (plastic) *7)
45
Connector DIN EN 175301-803
1
21000
Seals in either flow direction
VALVES
• 2/2-poppet valves electromagnetic actuated, directly controlled
Technical features
• G1/2 The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Medium: For neutral, gaseous and liquid fluids Operating pressure: 0 … 15 bar (0 … 217 psi) 0 … 50 bar (0 … 725 psi) Fluid temperature: -25°C … +80°C NBR Ambient temperature: -25°C … +80°C (-13°F … +176°F) -25°C … +60°C (-13°F … +140°F) Depending on solenoid system
Materials: Housing: Brass Seat seal: NBR Inner parts: Brass,Stainless steel 1.4104 (430 F)
Approval depends on magnetic system
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
46
Technical data Valves in protection class IP65 and Ex em Symbol
For further information www.imi-precision.com
2 10
12
Model *1)
Solenoids group
Port size
Orifice
Operating pressure (bar)
Flow (l/min)
2102250
30,5 A
G1/2
12
0 … 15
1100
2101850
38,5 A
G1/2
12
0 … 50
1100
1 2 10 2 10
12 12 1 1
2 12 please indicate 10solenoid, voltage and current (frequency). Valve function: APB = All Ports Blocked Approval depends on magnetic system. *1) When ordering, 2 10 12 1 1 2 10
12 1
23200
Seals in either flow direction
• G1/2, G1 The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Technical features Medium: Neutral gases and liquids, aggressive gases and liquids (with contaminated fluids upstream installation of a dirt trapis recommended) Operating pressure: 0 … 6 bar (0 … 87 psi) 0 … 10 bar (0 … 145 psi) Fluid/Ambient temperature: Depending on solenoid system -25°C … +80°C (-13°F … +176°F), Brass -10°C … +80°C (14°F … +176°F), Grey cast iron
VALVES
• 2/2-poppet valves electromagnetic actuated, directly controlled
Materials: Housing: brass 2.0401 or Grey cast iron Seat seal:NBR or FKM Inner parts: Brass 2.0401 (Ms 58), Stainless steel 1.4104 (430 F) Stainless steel 1.4104 (430 F)
Approval depends on magnetic system
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
47
Technical data Symbol
Model *1)
Port size
Solenoid-group
Orifice (mm)
Operating pressure (bar)
Flow (l/min)
Material Housing
2323120
G1/2
30,5A
12
0 … 10
1525
Brass
NBR
2322520 V-22C-all-E-FG 1
38,5A
25
0…6
9925
Grey cast iron
NBR
2323620
47,5A
25
0 … 10
9925
Grey cast iron
NBR
Seat seal
G1
2
*1) When ordering please indicate solenoid, voltage and current type (frequency).
V-22C-all-EH-F
1 2
V-22C-all-ER-F 1
For further information www.imi-precision.com
2 1
1
1
24000
VALVES
• 3/2 poppet valves electromagnetic actuated, directly controlled • G1/4, G1/2 The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Suited for outdoor use
Technical features Medium: For neutral, gaseous and liquid fluids Operating pressure: 0 … 12 bar (0 … 174 psi) 0 … 15 bar (0 … 217 psi) 0 … 25 bar (0 … 362 psi) 0 … 40 bar (0 … 580 psi) 0 … 100 bar (0 … 1450 psi) Ambient temperature: -25°C … +60°C (-13°F … 140°F) -40°C … +40°C (-40°F … 104°F)
Fluid temperature: -25°C … +80°C (-13°F … +176°F) NBR -40°C … +80°C (-40°F … +176°F) TPE Depending on solenoid system and Seal. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing Seat seal see Fluid temperature Inner part: Brass, Steel Approval depends on magnetic system
48
Technical data Symbol
Model *1)
For further information www.imi-precision.com
2 1
3 2
Port size
Solenoids group
Material Housing
Seat seal
G1/4
30,5A
8
0 … 15
750
Brass
NBR
G1/2
30,5A
12
0 … 12
1380
Brass
NBR
V-32O-all-E-F 2402750 G1/2
38,5A
12
0 … 25
1380
Brass
NBR
2406750
G1/2
38,5A
12
0 … 40
1380
Brass
NBR
2407965
G1/2
38,5A
12
0 … 100
1380
Brass
Stainless steel *2)
3
V-32O-all-ER-F 3
Flow (l/min)
2401550
2 1
Operating pressure (bar)
2402550
*1) When ordering please indicate solenoid, voltage and current type (frequency). V-32O-all-EH-F *2) Suitable for liquids only.
1
Orifice (mm)
21000, 23200 & 24000
1
Solenoids and accessories Model
Power consumption
Rated current
IP-Protection
Ex-Protection (ATEX-Category)
Ambient Temperature/Medium (°C)
Electrical connection
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
1300
21,4
–
891
–
IP65 (with cable gland)
–
-25 … +60
M20 x 1,5
1301
–
22,8
–
99
IP65 (with cable gland)
–
-25 … +60
M20 x1,5
1440
21,4
–
891
–
IP65 (with cable gland)
II 2G Ex e mb IIC T4/T5 Gb T4: -20 … +80 II 2D Ex tb IIIC T120°C Db IP65 T5: -40 … +60 -40 … +80
M20 x1,5
1441
–
22,8
–
99
IP65 (with cable gland)
II 2G Ex e mb IIC T4/T5 Gb T4: -20 … +80 II 2D Ex tb IIIC T120°C Db IP65 T5: -40 … +60 -40 … +80
M20 x1,5
IP-Protection
Ex-Protection (ATEX-Category)
Ambient Temperature/Medium (°C)
Electrical connection
VALVES
Solenoids Solenoids group 30,5A
Solenoids group 38,5A Model
Rated current
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
1500
38,7
–
1614
–
IP65 (with cable gland)
–
-25 … +60 Fluid max. +80
M20 x 1,5
1501
–
42,1
–
169
IP65 (with cable gland)
–
-25 … +60 Fluid max. +80
M20 x 1,5
1570
38,7
–
1614
–
IP65 (with cable gland)
II 2G Ex e mb IIC T4 Gb
-20 … +40
M20 x 1,5 *8)
1571
–
42,1
–
169
IP65 (with cable gland)
II 2G Ex e mb IIC T4 Gb
-20 … +40
M20 x 1,5 *8)
49
Power consumption
Model
Approvals ATEX IECEx
143x, 144x
KEMA 03 ATEX 1016 X
IECEx DEK 11.0066X
15xx, 157x
DEKRA BVS 08 ATEX E 117
–
Solenoids group 47,5A (only for Serie 23200) Model
Power consumption 24 V DC 230 V AC (W) (VA)
Rated current 24 V DC 230 V AC (mA) (mA)
IP-Protection
Ex-Protection (ATEX-Category)
Ambient Temperature/Medium (°C)
Electrical connection
1600
52,3
–
2181
–
IP65 (with cable gland)
–
-40 … +40 Fluid max. +80
M20 x 1,5 *3)
1601
–
56,4
–
245
IP65 (with cable gland)
–
-40 … +40 Fluid max. +80
M20 x 1,5 *3)
Standardvoltages 230 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN50014/50028. Duty cycle 100% ED. *3) Cable gland is not scope of delivery, see table »Accessories«. IP66 version on request.
Accessories Cable gland IP 65 Protection Ms Nickel plated brass
Model
Port size
Cable Ø
0589241
M 20x1,5
6,5 … 9,5 mm
0589242
M 20x1,5
9,0 … 13 mm
Cable gland Ex-Protection Ms Nickel plated brass
Model
Protection
Cable Ø
0588819
II 2GD Ex e
5 … 8 mm
0588851
II 2GD Ex d
10 … 14 mm
0588925
II 2GD Ex d
7,5 … 11,9 mm
For further information www.imi-precision.com
Approvals
1
95000
VALVES
• 2/2-poppet valves electromagnetic actuated, directly controlled • G1/4, 1/4 NPT, G1/2 The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
For a.c. solenoid systems with integrated rectifier (40 … 60 Hz)
Technical features Medium: For neutral gaseous and liquid fluids (with contaminated fluids, upstream installation of a dirt trap is recommended.) Operating pressure: 0 … 1 bar (0 … 14 psi) 0 … 5 bar (0 … 72 psi) 0 … 10 bar (0 … 145 psi) 0 … 12 bar (0 … 174 psi) 0 … 20 bar (0 … 290 psi) 0 … 35 bar (0 … 507 psi) 0 … 40 bar (0 … 580 psi)
Fluid/ Ambient temperature: -25°C … +80°C (-13°F … +176°F) NBR Depending on solenoid system and Seal. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Materials: Housing: Brass 2.0401 Seal: NBR Inner parts: Steel 1.4104 (430 F), Brass 2.0401 (Ms 58)
Approval depends on magnetic system
Technical data 50
Switching function: Normally closed Symbol
Model *1)
For further information www.imi-precision.com
2 1 2 1
Port size
Orifice (mm)
Operating pressure (bar)
Material Seat seal
Flow (l/min)
Solenoid group
9500100
G1/4
1,5
0 … 40
NBR
70
13B
9500200
G1/4
2
0 … 35
NBR
120
13B
9503200
1/4 NPT
2
0 … 35
NBR
120
13B
9500300
G1/4
3
0 … 10
NBR
200
13C
9503300
1/4 NPT
3
0 … 10
NBR
200
13C
9500400
G1/4
4
0 … 12
NBR
350
13D
9503400
1/4 NPT
4
0 … 12
NBR
350
13D
9501600
G1/4
6
0…5
NBR
550
16D
9504600
1/4 NPT
6
0…5
NBR
550
16D
9501700
G1/2
12
0…1
NBR
1700
16D
*1) When ordering please indicate solenoid, voltage and current type (frequency). Technical data and ordering2information see following pages.
1 Switching function: Normally open Symbol
2
Model *1)
Port size
Orifice (mm)
Operating pressure (bar)
Material Seat seal
Flow (l/min)
Solenoid group
9502210
G1/4
2
0 … 20
NBR
100
13B
G1/4
3
0 … 10
NBR
160
13B
V-22O-E-F 9502310
1
*1) When ordering please indicate solenoid, voltage and current type (frequency). 2 Technical data and ordering information see following pages.
V-22O-EH-F
1 2
V-22O-ER-F 1
96000 • G1/4, 1/4 NPT The solenoid valves are used in ATEXzones, resulting from Protection Class Atex-category of solenoids (see table of solenoids).
Technical features Medium: For neutral gaseous and liquid fluids (with contaminated fluids, upstream installation of a dirt trap is recommended.) Operating pressure: 0 … 9 bar (0 … 130 psi) 0 … 10 bar (0 … 145 psi) Fluid/Ambient temperature: -25°C … +80°C (-13°F … +176°F) NBR Depending on solenoid system and Seal.
Materials: Housing: Brass Seal: NBR Inner parts: Steel 1.4104 (430 F) Brass 2.0401 (Ms 58)
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
1 VALVES
• 3/2 poppet valves electromagnetic actuated, directly controlled
For a.c. solenoid systems with integrated rectifier (40 … 60 Hz)
Approval depends on magnetic system
Technical data Symbol
2
Port size
Orifice (mm)
Operating pressure (bar)
Materials: Seat
Flow (l/min)
Solenoid group
9600210
G1/4
2
0 … 10
NBR
120
13B
3
1/4 NPT
2
0 … 10
NBR
120
13B
9603210
*1) When ordering please indicate solenoid, voltage and current type (frequency).
Technical data and ordering information see following pages.
2
V-32C-EH-F 1
3
Switching function: Normally open 2
Symbol
Model *1)
Port size
Orifice (mm)
Operating pressure (bar)
Materials: Seat
Flow (l/min)
Solenoid group
9602210
G1/4
2
0…9
NBR
100
13B
1/4 NPT
2
0…9
NBR
100
13B
V-32C-ER-F 1 3 2
V-32O-E-F 1
3
9605210
2 *1) When ordering please indicate solenoid, voltage and current type (frequency).
V-32O-EH-F 1
3 2
V-32O-ER-F 1
3
Technical data and ordering information see following pages.
For further information www.imi-precision.com
Model *1)
V-32C-E-F 1
51
Switching function: Normally closed
1
95000/96000 Solenoids
VALVES
Solenoid group 13B, Standard voltages Model
Power consumption
Rated current
52
IP-Protection
Ex-Protection (ATEX-Category)
Temperature Ambient/Medium (°C)
Electrical connection
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
0246
8,0
–
331
–
IP65 (with Connector)
–
-25 … +60 Fluid: max. +80
Connector DIN EN 175301-803, Form A *2)
3206
–
9,2
–
40
IP65 (with Connector)
–
-25 … +60 Fluid: max. +80
Connector DIN EN 175301-803, Form A *8)
4210
3,9
–
162
–
IP66 (with cable II 2G Ex eb mb IIC T4/T6 Gb gland) II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
4211
–
5,3
–
23
IP66 (with cable II 2G Ex eb mb IIC T4/T6 Gb gland) II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
4610
3,9
–
162
–
IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
1/2 NPT *2)
4611
–
5,3
–
23
IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
1/2 NPT *2)
4612
3,9
–
162
–
IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
4613
–
5,3
–
23
IP66 (with cable Ex d mb IIC T4/T6 Gb gland) Ex e mb IIC T4/T6 Gb Ex tb IIIC T130°C Db
T4: -40 … +80 T6: -40 … +55 -40 … +80
M20 x 1,5 *2)
For further information www.imi-precision.com
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED. *2) Connectors/Cable gland is not included, see accessories. Attention: The protection class for coil series 46xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
Approvals Model
Approvals ATEX IECEx FM
42xx
KEMA 98 ATEX 4452 X
IECEx KEM 09.0068X
–
46xx
PTB 02 ATEX 2085 X
IECEx PTB 11.0094X
–
95000/96000 Solenoids
1
Model
Power consumption
Rated current
Ex-Protection (ATEX-Category)
Temperature Ambient/Medium (°C)
Electrical connection
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
0200
12,1
–
504
–
IP65 (with Connector)
–
-25 … +60 Fluid: max. +80
Connector DIN EN 175301-803, Form A *2)
3204
–
11,3
–
49
IP65 (with Connector)
–
-25 … +60 Fluid: max. +80
Connector DIN EN 175301-803, Form A *2)
4220
8,9
–
369
–
IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db
T4: -40 … +65 T5: -40 … +55 -40 … +65
M20 x 1,5 *2)
4221
–
10,0
–
43
IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db
T4: -40 … +65 T5: -40 … +55 -40 … +65
M20 x 1,5 *2)
4620
8,9
–
369
–
IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 T6: -40 … +40 -40 … +70
1/2 NPT *2)
4621
–
10,0
–
43
IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 T6: -40 … +40 -40 … +70
1/2 NPT *2)
4622
8,9
–
369
–
IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 T6: -40 … +40 -40 … +70
M20 x 1,5 *2)
4623
–
10,0
–
43
IP66 (with cable II 2G Ex d mb IIC T4/T6 Gb gland) II 2G Ex e mb IIC T4/T6 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +70 T6: -40 … +40 -40 … +70
M20 x 1,5 *2)
Approvals Model
Approvals ATEX IECEx FM
42xx
KEMA 98 ATEX 4452 X
IECEx KEM 09.0068X
–
46xx
PTB 02 ATEX 2085 X
IECEx PTB 11.0094X
–
For further information www.imi-precision.com
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED. *2) Connectors/Cable gland is not included, see accessories. Attention: The protection class for coil series 46xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
53
IP-Protection
VALVES
Solenoid group 13C, Standard voltages
1
95000/96000 Solenoids
VALVES
Solenoid group 13D, Standard Voltage Model
Power consumption
Rated current
IP-Protection
Ex-Protection (ATEX-Category)
Temperature Ambient/Medium (°C)
Electrical connection
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
0700
16,9
–
703
–
IP65 (with Connector)
–
-25 … +60 Fluid: max. +80
Connector DIN EN 175301-803, Form A *2)
3703
–
19,5
–
75
IP65 (with Connector)
–
-25 … +60 Fluid: max. +80
Connector DIN EN 175301-803, Form A *2)
4230
11,4
–
475
–
IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
M20 x 1,5 *2)
4231
–
15,2
–
66
IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
M20 x 1,5 *2)
4630
11,4
–
475
–
IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
1/2 x NPT *2)
4631
–
15,2
–
66
IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
1/2 x NPT *2)
4632
11,4
–
475
–
IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
M20 x 1,5 *2)
4633
–
15,2
–
66
IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
M20 x 1,5 *2)
54
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED. *2) Connectors/Cable gland is not included, see accessories. Attention: The protection class for coil series 46xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
For further information www.imi-precision.com
Approvals Model
Approvals ATEX IECEx
42xx
KEMA 98 ATEX 4452 X
IECEx KEM 09.0068X
46xx
PTB 02 ATEX 2085 X
IECEx PTB 11.0094X
95000/96000 Solenoids and accessories
1
Model
Power consumption
Rated current
IP-Protection
Ex-Protection (ATEX-Category)
Temperature Ambient/Medium (°C)
Electrical connection
24 V DC 230 V AC (W) (VA)
24 V DC 230 V AC (mA) (mA)
0800
16,9
–
703
–
IP65 (with Connector)
–
-25 … +60 Fluid: max. +80
Connector DIN EN 175301-803 Form A *2)
3803
–
19,5
–
75
IP65 (with Connector)
–
-25 … +60 Fluid: max. +80
Connector DIN EN 175301-803 Form A *2)
4280
11,4
–
475
–
IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
M20 x 1,5 *2)
4281
–
15,2
–
66
IP66 (with cable II 2G Ex eb mb IIC T4/T5 Gb gland) II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
M20 x 1,5 *2)
4680
11,4
–
475
–
IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
1/2 x NPT *2)
4681
–
15,2
–
66
IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
1/2 x NPT *2)
4682
11,4
–
475
–
IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
M20 x 1,5 *2)
4683
–
15,2
–
66
IP66 (with cable II 2G Ex d mb IIC T4/T5 Gb gland) II 2G Ex e mb IIC T4/T5 Gb II 2D Ex tb IIIC T130°C Db
T4: -40 … +50 T5: -40 … +40 -40 … +50
M20 x 1,5 *2)
Approvals Model
Approvals ATEX IECEx KEMA 98 ATEX 4452 X
IECEx KEM 09.0068X
PTB 02 ATEX 2085 X
IECEx PTB 11.0094X
Accessories Cable gland Protection Ex e, Ex d (ATEX)
Model
For solenoid
Thread
Cable Ø (mm)
Material
Protection class (ATEX)
Ambient temperature limitation
0589735
42xx
M20 x 1,5
7,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *3)
0589736
42xx
M20 x 1,5
10,0 … 14,0 Plastic
II 2G Ex e / II 2D Ex t
See table *3)
0589737
42xx
M20 x 1,5
6,0 … 12,0
Plastic
II 2G Ex e / II 2D Ex t
See table *3)
0588819
46xx
M20 x 1,5
5,0 … 8,0
Nickel plated brass
II 2G Ex e / II 2D Ex t
–
0588851
46xx
M20 x 1,5
10,0 … 14,0 Nickel plated brass
II 2G Ex d / II 2D Ex t
–
0588925
46xx
1/2 NPT
7,5 … 11,9
II 2G Ex d / II 2D Ex t
–
Nickel plated brass
*3) The limitation of the temperature range to the mentioned range is due to the self-heating of the solenoid.
For solenoid
421x/426x
422x/427x
423x/428x
Ambient temperature limitation solenoid 42xx 0589735 & 0589736 *4)
0589737
T4 & Dust Ex: -35°C … + 80°C
T4 & Dust Ex: -40°C … + 65°C
T6: -35°C … + 55°C
T6: -40°C … + 55°C
T4 & Dust Ex: -35°C … +65°C
T4 & Dust Ex: -40°C … + 62°C
T5: -35°C … + 55°C
T5: -40°C … + 55°C
T4 & Dust Ex: -35°C … +50°C
T4 & Dust Ex: -40°C … +50°C
T5: -35°C … +40°C
T5: -40°C … +40°C
*4) Tested for the lower level of mechanical risk (4 joule), an additional protection against impacts might be needed.
Connector DIN EN 175301-803
0570275, Form A
For further information www.imi-precision.com
42xx 46xx
55
Standard voltages (±10%) 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. Duty cycle 100% ED. *2) Connectors/Cable gland is not included, see accessories. Attention: The protection class for coil series 46xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb.
VALVES
Solenoid group 16D, Standard Voltage
1
6316 Inline
VALVES
• 3/2 poppet valves
Technical features
• Electromagnetic actuated, Manual Override (optional)
Medium: Compressed Air Operating pressure: 0 … 8 bar (0 … 116 psi) Orifice: 3 mm Flow direction: Fixed Ambient/Media temperature: Ambient: -20°C … +60°C (-4°F … +140°F) Media: -20°C … +80°C (-4°F … +176°F) Depending on solenoid system
• G1/4, 1/4 NPT • For single acting actuators • Protection class of Coil is up to IP 65 * ATEX Version available from July 2017
Materials: Body: Aluminum (Anodized), Brass and SS 316L for critical environment conditions. Seals: FKM Note: For Outdoor installations Coil must be protected from moisture by using cable gland of IP 65 or above.
Valve switches at power NO, NC, failure into starting Universal valve position (Mechanical return spring)
Suited for outdoor use under IP 65 conditions
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
3/2 Way Universal Valves with temperature -20°C … +80°C, Housing: Aluminum, Brass and SS316L Symbol
2
1 3
56
Model *1)
Port size
Material
Actuation/return
Operating pressure (bar)
Flow (l/min)
Weight (kg)
631605316001***
G1/4
Aluminium
Solenoid/ air spring
0…8
340
0,33
631605416001***
1/4 NPT
Aluminium
Solenoid/ air spring
0…8
340
0,33
631615316001***
G1/4
Brass
Solenoid/ air spring
0…8
340
0,67
631615416001***
1/4 NPT
Brass
Solenoid/ air spring
0…8
340
0,67
631625316001***
G1/4
SS 316L
Solenoid/ air spring
0…8
340
0,65
631625416001***
1/4 NPT
SS 316L
Solenoid/ air spring
0…8
340
0,65
*1) When ordering, please indicate solenoid, voltage and current (frequency).
For further information www.imi-precision.com
Voltage
Substitute
24 V d.c.
02400
110 V a.c.
11050
230 V a.c.
23050
Flow 1 bar differential pressure ~ 160 lpm.
Solenoids, standard voltages Model
Power consumption 24 V d.c. 110 V a.c. (W) (VA) ~-18 –
230 V a.c. (VA) –
Rated current 24 V d.c. 110 V a.c. (A) (A) ~0,7 –
230 V a.c. (A) –
–
~-18
–
–
~0,14
–
IP 65 (with connector)
–
–
~-18
–
–
~0,08
IP 65 (with connector)
6316****.6001
6316****.6001
6316****.6001 Standard voltages (±10%) 24 V d.c., 110 V a.c., 230 V a.c., other voltages on request. 100% duty cycle. Note: For Outdoor installations Coil must be protected from moisture by using cable gland of IP 65 or above. Coil Insulation Class – H Degree of protection applies to complete assembly composed of valve and coil, with electrical wiring according to IP 65.
Protection class IP/NEMA IP 65 (with connector)
Temperature Ambient/Media (°C) Ambient: -20 … +60 Fluid: -20 … +80 Ambient: -20 … +60 Fluid: -20 … +80 Ambient: -20 … +60 Fluid: -20 … +80
Electrical connection Connector M20 x 1,5
Weight (kg) 0,35
Connector M20 x 1,5
0,36
Connector M20 x 1,5
0,36
Temperatures mentioned refer to coils only. This coil has a fuse with an appropriate rating. Electrical connector – terminal type (with metal cable entry). For other power coils please contact Engineering Team.
Accessories Inlet filter
Silencer (plastic) *2)
Silencer (stainless steel) *2)
Silencer (brass) *2)
Exhaust guard *3)
0681173 (G1/4, 1/4 NPT)
C/S2 (1/4 NPT)
0613678 (1/4 NPT)
MS002A (1/4 NPT)
0613422 (G1/4, 1/4 NPT)
*2) For indoors use only. *3 For outdoors use, opening pressure 0,2 bar.
ICO3S Technical features
• Electromagnetically actuated, direct solenoid operated. 1/4 NPT
Medium: Hydraulic and pneumatic – customer to specify and confirm compatibility Operating pressure: 0 … 12 bar (0 … 174 psi) Fluid temperature: -55°C … +69°C (-67°F … 156°F)
Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: high NBR
1 VALVES
• 3/2 Exia poppet valves
Reliable and long life, ideal for a one time installation
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
SIL2 @ HFT=0 SIL3 @ HFT=1
Symbol
2
57
Technical data - standard models Port size
Function
Operating pressure (bar)
Manual override/ reset
Conduit connection
ATEX
Temperature range Media Ambient (°C) (°C)
YX13AA1H1BS
1/4 NPT
3/2 NC
0 … 12
Without
M20 x 1,5
Ex II 2 GD, Ex ia IIC
-55 … +69°C
-55 … +69°C
5/2
0 … 12
Without
M20 x 1,5
Ex II 2 GD, Ex ia IIC
-55 … +69°C
-55 … +69°C
V-32C-E-F 1
3 4
2
2
4
1/4 NPT
V-52-E-F
513
1
YX15AA1H1BS
3
V-32C-EH-F
2
2
V-52-EH-F
Technical data 5 1 3 – Solenoids V-32C-ER-F 14 32 Nominal voltages Pull-in voltage
513
24 V d.c. via an energy limiting barrier
V-52-EH-F
≥ 87,5% of nominal
Response times
Pull-in 3 … 4 seconds, drop out < 60 ms
Drop-out voltage
10 … 20% of nominal
Coil rating
293 ohms
Power consumption
0,43 watts typical
Voltage protection
Surge suppression diodes fitted as standard
Coil encapsulation
Class H
Leak performance
Bubble tight at 50°C < 30 cc/m at -55°C
Coil duty cycle
100%
For further information www.imi-precision.com
Model
1
ICO3S
VALVES
Reliable and long life, ideal for a one time installation
• 3/2 or 5/2 poppet valves
Technical features
• Electromagnetically actuated, direct solenoid operated. 1/4 NPT … 1/2 NPT
Medium: Hydraulic and pneumatic – customer to specify and confirm compatibility Operating pressure: 0 … 12 bar (0 … 174 psi) Fluid temperature: -55°C … +90°C (-67°F … +194°F) Ambient temperature: See table.
Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: NBR Other seal materials available on request
SIL2 @ HFT=0 SIL3 @ HFT=1
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
58
Technical data – standard models with conduit connection M20 x 1,5 Symbol
For further information www.imi-precision.com
Model
Port size
Function
Operating pressure (bar)
Manual override/ reset
ATEX certification
Power consumption at 24 Vdc (W)
Ambient temperature
Y013AA1H1BS
1/4 NPT
3/2 UNI
0 … 12
Without
Ex II 2 GD, Exd IIC
3
T6 (-55 … +50°C), T4 (+90°C max)
Y013AA3H1BS
1/2 NPT
3/2 UNI
0 … 12
Without
Ex II 2 GD, Exd IIC
7,8
T6 (-55 … +50°C), T4 (+90°C max)
Y015AA1H1BS
1/4 NPT
5/2 UNI
0 … 12
Without
Ex II 2 GD, Exd IIC
7,8
T6 (-55 … +50°C), T4 (+90°C max)
1/2 NPT
5/2 UNI
0 … 12
Without
Ex II 2 GD, Exd IIC
7,8
T6 (-55 … +50°C), T4 (+90°C max)
2
V-32C-E-F
1
3 2
1
4
3
2
V-52-E-F
25 1 3 1
4
3
V-32C-EH-F
2
Y015AA3H1BS
V-32C-ER-F V-52-EH-F
513 4
2
V-52-EH-F 513
ICO4S Technical features Medium: Hydraulic and pneumatic – customer to specify and confirm compatibility Operating pressure: 0 … 20 bar (0 … 290 psi) Fluid temperature: -20°C … +90°C (-4°F … +194°F) Options to -60°C (-76°F) Cavailable on request
Ambient temperature: See table. Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: high NBR
SIL2 @ HFT=0 SIL3 @ HFT=1
Port size
Function
Operating pressure (bar)
Material Seat seal
Manual override/ reset
ATEX certification
Power consumption 24 V d.c. (W)
Ambient temperature
Y123AA1H1BS
1/4 NPT
3/2 UNI
0 … 20
NBR
Without
Exd IIC T6
4,5
T6 (-60 … +48°C), T4 (-60 … +90°C )
1/2 NPT
3/2 UNI
0 … 20
NBR
Without
Exd IIC T6
9,6
T6 (-60 … +48°C), T4 (-60 … +90°C )
V-32C-EH-F1/4 NPT V-52-E-F
5/2 UNI
0 … 20
NBR
Without
Exd IIC T6
9,6
T6 (-60 … +48°C), T4 (-60 … +90°C )
V-32C-E-F
Y123AA3H1BS
3 2
4
1
2
3
513 2 4 2
1 3 513 4
Y125AA3H1BS
V-32C-ER-F V-52-EH-F
2
V-52-EH-F 513
For further information www.imi-precision.com
Model
2 1
59
Technical data – standard models with conduit connection M20 x 1,5 Symbol
1 VALVES
• 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled. 1/4 NPT
Reliable and long life, ideal for a one time installation
Introducing ICO4-PST The first smart solenoid valve with fully integrated partial stroke testing Working closely with customers in the global oil and gas industry, we see the need for a no compromise solution for partial stroke testing. It is clear that the best way to eliminate the compromises of positioner systems is to use the control mechanism of the electronic solution; whilst the best way to eliminate the compromises of the electronic solution is to employ the packaging of the positioner system.
Find out more www.imi-precision.com
Now add to this the benefits of using a high integrity solenoid valve and we are left with a clear path â&#x20AC;&#x201C; namely, the integration of the PST control electronics into the termination housing of a high integrity solenoid valve. Working closely with customers in the global oil and gas industry, we see the need for a no compromise solution for partial stroke testing. It is clear that the best way to eliminate the compromises of positioner
systems is to use the control mechanism of the electronic solution; whilst the best way to eliminate the compromises of the electronic solution is to employ the packaging of the positioner system. Now add to this the benefits of using a high integrity solenoid valve and we are left with a clear path â&#x20AC;&#x201C; namely, the integration of the PST control electronics into the termination housing of a high integrity solenoid valve.
Compatible with Redundant Valve Manifold
Compatible with hydraulic actuators
Simplifies engineering process
Ideal for retrofit
The ICO4-PST is the first fully integrated partial stroke testing solution with the control system built into the market leading IMI Maxseal ICO4 high integrity solenoid valve. With the lowest safe and dangerous failure rates of any intelligent PST system on the market and always providing the highest possible Diagnostic Coverage, the best possible SIL performance is guaranteed.
> No dedicated PST device required therefore significantly reduces engineering requirements > High level diagnostics with position, pressure and time monitoring > Simple Pass/Fail reporting > Dual override mechanism eliminates possibility of over-stroke
> Compatible with valve speeds from 2 to 120 seconds > SIL 3 certified as 1oo1 > -40°C â&#x20AC;Ś +60°C > Local testing using HART 475 communicator, remote testing via HART
Engineering GREAT Solutions
Fully flexible manifold options available
ICO4-PST The flexible solution Another product of our innovation and technical excellence, the ICO4-PST is reliable and flexible, and can be designed to your specification. Manifold options are available depending specific environmental and application requirements.
> Solenoid configurations > 1oo1, 1oo2, 2oo2, 2oo3
> Valves > Ball, butterfly, gate, globe, HIPPS
> High flow rate Cv up to 5.0 > Reduces requirements for QEVs, pilot valves & boosters
> Valve Speeds > 2s to 120s
> Actuator Types > Pneumatic, hydraulic > Spring return > Quarter turn, linear
> Operating temperature range > -40°C … +60°C > Retrofit > Ideal for retrofit applications due to engineering simplicity
Engineering GREAT Solutions
Find out more www.imi-precision.com
ICO4-PST • Partial Stroke Testing integrated into the ICO4 valve
Technical features Medium: Pneumatic – customer to specify and confirm compatibility Operation: Direct solenoid operated poppet valves with integral pressure transmitter Operating pressure: 0 … 10 bar (0 … 145 psi) Mounting position: Solenoid vertical Ambient temperature: 1/4 … 1/2 NPT resp. G1/4 … 1/2 -40°C … +60°C 3/4 NPT resp. G3/4 -40°C … +50°C
Materials: Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L) O-rings seats & seals: NBR/FPM
Dramatically reduces engineering requirements
Other seal materials available on request
SIL2 @ HFT=0 SIL3 @ HFT=1
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
P
1
3 2
C
Model
Port size
Cv
Conduit connection
Material Seat seal
Y413AA1H2BS
1/4 NPT
0,8
1/2 NPT
NBR
Y413AE1H1BS
G1/4
0,8
M20 x 1,5
NBR
Y413AA3H2BS
1/2 NPT
2,1
1/2 NPT
NBR
Y413AE3H1BS
G1/2
2,1
M20 x 1,5
NBR
Y413AA5H2BS
3/4 NPT
5
1/2 NPT
NBR
Y413AE5H1BS
G3/4
5
M20 x 1,5
NBR
P
1
3 2
C
P
Electrical details 1
ATEX details
3
Voltage:
24 V d.c.
Certification:
Ex db IIC T4/T6
Voltage tolerance Power consumption:
±12,5% of Nominal
Model: Ambient temperature:
Insulation class
Class H
ICO4E T4: 1/4 … 1/2 NPT resp. G1/4 … 1/2 -40 … +60°C (-40 … +140°F) 3/4 NPT resp. G3/4 -40 … +50°C (-40 … +122°F) T6: -40 … +43°C (-40 … +110°F)
Conduit connection IP-Protection class EN 60529
1/2 NPT or M20 x 1,5 IP66
Additional Global Approvals:
In-Metro, TR CU, Class I Div 1 FM3600 / FM3615 / CSA 22.2
Rating: Charging (~4 Mins) 6,7 W (1/4”); 9,7 W (1/2”), 17,4 W (3/4”) Steady-State 5,7 W (1/4”); 8,7 W (1/2”), 16,4 W (3/4”)
For further information www.imi-precision.com
2 C
63
Technical data – standard models Symbol
VALVES
• 3/2 Smart solenoid poppet valves; 1/4 NPT … 3/4 NPT, G1/4 … G3/4
1
1
82400 & 82730
VALVES
• Indirect solenoid actuated diaphragm valves
Solenoid interchangeable without tools (Click-on®)
Technical features Medium: Neutral gases and liquids (82400) Slightly aggressive gases and liquids (82730) Flow direction: Fixed Operating pressure: 0,1 … 16 bar (1,4 … 232 psi) for Details, See table Temperature: Fluid -10°C … +90°C (14°F … +194°F) max. Ambient -10°C … +50°C (14°F … +122°F) max.
• 2/2 N/C, G1/4 … G2
Materials: Body: Brass (82400) or Stainless steel (82730) Seat Seal: NBR Internal parts: Stainless steel, PVDF, For contaminated fluids installations of a strainer is recommended
Models 64
Brass – For neutral, gases and liquids Symbol
Model
For further information www.imi-precision.com
A P
Orifice (mm)
Port size
Kv-value *1) (m3/h)
Operating pressure (bar)
8240000.9101.02400
8
G1/4
1,9
0,1 … 16
8240100.9101.02400
10
G3/8
3
0,1 … 16
8240200.9101.02400
12
G1/2
3,8
0,1 … 16
8240300.9101.02400
20
G3/4
6,1
0,1 … 16
8240400.9101.02400
25
G1
9,5
0,1 … 16
8240500.9101.02400
32
G1 1/4
23
0,1 … 10
8240500.9151.02400
32
G1 1/4
23
0,1 … 16
8240600.9101.02400
40
G1 1/2
25
0,1 … 10
8240600.9151.02400
40
G1 1/2
25
0,1 … 16
8240700.9101.02400
50
G2
41
0,1 … 10
8240700.9151.02400
50
G2
41
0,1 … 16
Model
Orifice (mm)
Port size
Kv-value *1) (m3/h)
Operating pressure (bar)
8273000.9101.02400
8
G1/4
1,9
0,1 … 16
8273200.9101.02400
12
G1/2
3,8
0,1 … 16
8273300.9101.02400
20
G3/4
6,1
0,1 … 16
8273400.9101.02400
25
G1
9,5
0,1 … 16
8273500.9101.02400
32
G1 1/4
23
0,1 … 10
8273500.9151.02400
32
G1 1/4
23
0,1 … 16
8273600.9101.02400
40
G1 1/2
25
0,1 … 10
8273600.9151.02400
40
G1 1/2
25
0,1 … 16
8273700.9101.02400
50
G2
41
0,1 … 10
8273700.9151.02400
50
G2
41
0,1 … 16
*1) Cv-value (US) ≈ kv value x 1,2.
Stainless steel – For aggressive gases and liquids Symbol
A P
*1) Cv-value (US) ≈ kv value x 1,2.
82400 & 82730
1 Electrical details for all solenoid systems
Voltage and Frequency Solenoid 9101 *2) Code Voltage 024
Code Frequency 00
Voltage
24 V DC
Frequency
–
Power consumption Inrush- Holdingpower power 8W
8W
024
50
24 V AC
50 Hz
15 VA
12 VA
110
50
110 V AC
50 Hz
15 VA
12 VA
120
60
120 V AC
60 Hz
15 VA
12 VA
230
50
230 V AC
50 Hz
15 VA
12 VA
Design
DIN VDE 0580
Voltage range
±10%
Duty cycle
100% ED
Protection
EN 60529 IP65
Connector
Form A to DIN EN 175301-803 (included)
VALVES
Solenoids
According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.
Voltage and Frequency Solenoid 9151 *2) 024
00
24 V DC
–
18 W
18 W
024
50
24 V AC
50 Hz
45 VA
35 VA
110
50
110 V AC
50 Hz
45 VA
35 VA
120
60
120 V AC
60 Hz
45 VA
35 VA
230
50
230 V AC
50 Hz
45 VA
35 VA
*2)
Voltage.
Other functions and operating voltages available on request
65
Additional solenoid systems Protection
Solenoid
Standard voltage
II 2GD
EEx m II T4 T 130°C with 3 m Connection cable
9136
24 V DC, 110 V AC, 230 V AC
II 2G II 2D
Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db
6126
24 V DC, 110 V AC, 230 V AC
II 2G II 2D
Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db
6120
24 V DC, 110 V AC, 230 V AC
II 2G II 2D
Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db
6106
24 V DC, 110 V AC, 230 V AC
Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.
For further information www.imi-precision.com
ATEX Category
1
82470
VALVES
• Indirect solenoid actuated diaphragm valves
Solenoid interchangeable without tools (Click-on®)
Technical features Medium: Hot water and steam Flow direction: Fixed Operating pressure: 0,1 … 10 bar (1,4 … 145 psi) for Details, See table Temperatur: Fluid 0°C … +150°C (32°F … +302°F) max. Ambient -10°C … +60°C (14°F … +140°F) max.
• 2/2 N/C, G1/4 … G1
Materials: Body: Brass Seat seal: HNBR Internal Parts: Stainless steel, Brass For contaminated fluids installations of a strainer is recommended.
Models 66
Brass For neutral gases and liquids Symbol
For further information www.imi-precision.com
A P
Model
Orifice (mm)
Port size
Kv-value (m3/h)
Operating pressure (bar)
8247000.9100.00000
8
G1/4
1,7
0,1 … 10
8247100.9100.00000
10
G3/8
2,7
0,1 … 10
8247200.9100.00000
12
G1/2
3,4
0,1 … 10
8247300.9100.00000
20
G3/4
5,5
0,1 … 10
8247400.9100.00000
25
G1
8,5
0,1 … 10
Solenoids
Electrical details for all solenoid systems
Voltage and Frequency Solenoid 9101 *1) Code Voltage
Code Frequency
Voltage
Frequency
Design
DIN VDE 0580
Power consumption Inrush- Holdingpower power
Voltage range
±10%
Duty cycle
100% ED
Protection
EN 60529 IP65
Connector
Form A to DIN EN 175301-803 (included)
024
00
24 V DC
-
8W
8W
024
50
24 V AC *2)
50 Hz
15 VA
12 VA
110
50
110 V AC *2)
50 Hz
15 VA
12 VA
120
60
120 V AC *2)
60 Hz
15 VA
12 VA
230
50
230 V AC *2)
50 Hz
15 VA
12 VA
*1) Voltage. *2) A.c. only with rectifier plug.
Other functions and operating voltages available on request
According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.
82540, 82590 Solenoid interchangeable without tools (Click-on®) • Solenoid actuated diaphragm valve with forced lifting • 2/2 N/C, G1/4 … G2
Models - Brass Symbol
A P
VALVES
Technical features Medium: Neutral gases and liquids (82540) Slightly aggressive, gases and liquids (82590) Flow direction: Fixed Operating pressure: 0 … 10 bar (0 … 145 psi) Temperatur: Fluid -10°C … +90°C (14°F … +194°F) max. Ambient -10°C … +50°C (14°F … +122°F) max.
1
Materials: Body: Brass (82540) Stainless steel (82590) Seat Seal: NBR-K Internal Parts: Stainless steel, PVDF, Brass For contaminated fluids installations of a strainer is recommended.
Model Solenoid in V d.c.
Solenoid in V a.c.
Orifice (mm)
Port size
Kv-value (m3/h)
Operating pressure (bar)
8254000.9151.00000
8254000.9154.00000
8
G1/4
1,9
0 … 10
8254100.9151.00000
8254100.9154.00000
10
G3/8
3
0 … 10
8254200.9151.00000
8254200.9154.00000
12
G1/2
3,4
0 … 10
8254300.9151.00000
8254300.9154.00000
20
G3/4
5,8
0 … 10
8254400.9151.00000
8254400.9154.00000
25
G1
8
0 … 10
8254500.9401.00000
8254500.9404.00000
32
G1 1/4
23
0 … 16
8254600.9401.00000
8254600.9404.00000
40
G1 1/2
25
0 … 16
8254700.9401.00000
8254700.9404.00000
50
G2
41
0 … 16
Orifice (mm)
Port size
Kv-value (m3/h)
Operating pressure (bar)
Models - Stainless steel Model
A
8259000.9154.00000
8
G1/4
1,9
0 … 10
8259100.9150.00000
8259100.9154.00000
10
G3/8
3
0 … 10
8259200.9150.00000
8259200.9154.00000
12
G1/2
3,4
0 … 10
8259300.9150.00000
8259300.9154.00000
20
G3/4
5,8
0 … 10
8259400.9150.00000
8259400.9154.00000
25
G1
8
0 … 10
8259500.9401.00000
8259500.9404.00000
32
G1 1/4
23
0 … 16
8259600.9401.00000
8259600.9404.00000
40
G1 1/2
25
0 … 16
8259700.9401.00000
8259700.9404.00000
50
G2
41
0 … 16
Solenoids
Electrical details for all solenoid systems
Voltage and Frequency Solenoid 9151/9154 *1) Code Voltage
Code Voltage Frequency
Frequency
Power consumption Inrush- Holdingpower power
024
00
24 V DC
-
18 W
18 W
024
49
24 V AC
40 … 60 Hz 20 VA
20 VA
110
49
110 V AC
40 … 60 Hz 20 VA
20 VA
120
49
120 V AC
40 … 60 Hz 20 VA
20 VA
230
49
230 V AC
40 … 60 Hz 20 VA
20 VA
Design
DIN VDE 0580
Voltage range
±10%
Duty cycle
100% ED
Protection
EN 60529 IP65
Connector
Form A to DIN EN 175301-803 (included)
According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.
Additional solenoid systems
Voltage and Frequency Solenoid 9301/9304 *1) 024
00
24 V DC
-
18 W
18 W
024
49
24 V AC
50 Hz
20 VA
20 VA
110
49
110 V AC
50 Hz
20 VA
20 VA
120
49
120 V AC
60 Hz
20 VA
20 VA
230
49
230 V AC
50 Hz
20 VA
20 VA
Voltage and Frequency Solenoid 9401/9404 *1) 024
00
24 V DC
-
38 W
38 W
024
49
24 V AC
40 … 60 Hz 42 VA
42 VA
110
49
110 V AC
40 … 60 Hz 42 VA
42 VA
120
49
120 V AC
40 … 60 Hz 42 VA
42 VA
230
49
230 V AC
40 … 60 Hz 42 VA
42 VA
*1)
Voltage.
Other functions and operating voltages available on request
ATEX Category II 2GD
Protection EEx me II T3 T 140°C
Solenoid 9356
Standard voltage 24 V DC, 110 V AC, 230 V AC
II 3GD
EEx nA II T4 T 135°C
9326
24 V DC, 110 V AC, 230 V AC
II 3GD
EEx nA II T4 T 135°C
8426
24 V DC, 110 V AC, 230 V AC
II 2GD
EEx me II T3 T 140°C
8441
24 V DC, 110 V AC, 230 V AC
II 3GD
EEx nA II T4 T 135°C
9176
24 V DC, 110 V AC, 230 V AC
II 2GD
EEx me II T3 T 140°C
9191
24 V DC, 110 V AC, 230 V AC
II 3GD
EEx nA II T4 T 135°C
9426
24 V DC, 110 V AC, 230 V AC
II 2G II 2D II 2G II 2D II 2G II 2D
Ex eb mb IIC T3 Gb Ex mb tb IIIB T135°C Db IP65 Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db
6140
24 V DC, 110 V AC, 230 V AC
6240
24 V DC, 110 V AC, 230 V AC
6120
24 V DC, 110 V AC, 230 V AC
Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.
For further information www.imi-precision.com
P
8259000.9150.00000
67
Symbol
1
82960, 82970
VALVES
• 2/2-way diaphragm valves
Technical features
• G3/4 … 3, 3/4 … 2 1/2 NPT
Medium: Compressed air Flow direction: Fixed Operating pressure: 0,4 … 7/8 bar (5,8 … 101/116 psi) Dusty gas temperature: -20°C … +85°C (-4°F … +185°F) Cleaning gas temperature: -40°C … +85°C (-40°F … +185°F) Ambient temperature: -20°C … +85°C (-4°F … +185°F)
Solenoid interchangeable without tools (Twist-on®)
Materials: Body: Aluminium Seat Seal: TPE Internal Parts: TPU
Easy to maintain
Technical data - Standard models Symbol
A P
68
A P
For further information www.imi-precision.com
Model
Port size
Orifice (mm)
Valve length (mm)
Kv-value *1) (m3/h)
Operating pressure (bar)
8296300.8171.xxxxx
G3/4
20
95
18
0,4 … 8
8297300.8171.xxxxx
3/4 NPT
20
95
18
0,4 … 8
8296400.8171.xxxxx
G1
25
95
22
0,4 … 8
8297400.8171.xxxxx
1 NPT
25
95
22
0,4 … 8
8296600.8171.xxxxx
G1 1/2
40
135
59
0,4 … 8
8297600.8171.xxxxx
1 1/2 NPT
40
135
59
0,4 … 8
8296700.8171.xxxxx
G2
50
169
80
0,4 … 8
8297700.8171.xxxxx
2 NPT
50
169
80
0,4 … 8
8296800.8171.xxxxx
G2 1/2
65
169
93
0,4 … 8
8297800.8171.xxxxx
2 1/2 NPT
65
169
93
0,4 … 8
8296900.8171.xxxxx
G3
80
239,5
172
0,4 … 7
xxxxx Please insert voltage and frequency codes. *1) Cv-value (US) ≈ kv value x 1,2.
Solenoids
Electrical details for all solenoid systems
Voltage and Frequency Solenoid 8171 *2) Code Voltage
Code Frequency
Voltage
Frequency
Power consumption Inrush- Holdingpower power
024
00
24 V DC
-
12 W
12 W
024
50
24 V AC
50 Hz
23 VA
16 VA
110
50
110 V AC
50 Hz
23 VA
16 VA
120
60
120 V AC
60 Hz
23 VA
16 VA
230
50
230 V AC
50 Hz
23 VA
16 VA
*2)
Design
DIN VDE 0580
Voltage range
±10%
Duty cycle
100% ED
Protection
EN 60529 IP65
Connector
Form A to DIN EN 175301-803 (included)
According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.
Voltage.
Additional solenoid systems
Additional solenoid systems
ATEX Category
Protection
Solenoid
Standard voltage
Option
Solenoid
Standard voltage
II 3GD
EEx nA II T4 T 135°C
8176
24 V DC, 110 V AC, 230 V AC
Solenoid version for low temperature = 40°C
9151
24 V DC, 110 V AC, 230 V AC
II 2GD
EEx me II T4 T 140°C
8186
24 V DC, 110 V AC, 230 V AC
Pulse Solenoid
8821
24 V DC, 110 V AC, 230 V AC
8001
24 V DC, 110 V AC, 230 V AC
24 V DC, 110 V AC, 230 V AC
Solenoid version for low temperature = 40°C
II 2G II 2D
Ex eb mb IIC T4 Gb Ex mb tb IIIB T135°C Db
6176
Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.
82900, 82910 One-piece diaphragm
Technical features
• G3/4 … 3, 3/4 … 2 1/2 NPT
Medium: Compressed air Operating pressure: 0,4 … 7/8 bar (5,8 … 101/116 psi) Dusty gas temperature: -20°C … +85°C (-4ºF … +185°F) Cleaning gas temperature: -40°C … +85°C (-40ºF … +185°F) Ambient temperature: -40°C … +85ºC (-40ºF … +185ºF)
Materials: Body: Aluminium Seat Seal: TPE
Model
P
Z
A P
*1) Cv-value (US) ≈ kv value x 1,2.
Port size
Orifice (mm)
Valve length (mm)
Kv-value *1) (m3/h)
Operating pressure (bar)
8290300.0000.00000
G3/4
20
95
18
0,4 … 8
8291300.0000.00000
3/4 NPT
20
95
18
0,4 … 8
8290400.0000.00000
G1
25
95
22
0,4 … 8
8291400.0000.00000
1 NPT
25
95
22
0,4 … 8
8290600.0000.00000
G1 1/2
40
135
59
0,4 … 8
8291600.0000.00000
1 1/2 NPT
40
135
59
0,4 … 8
8290700.0000.00000
G2
50
170
80
0,4 … 8
8291700.0000.00000
2 NPT
50
170
80
0,4 … 8
8290800.0000.00000
G2 1/2
65
170
93
0,4 … 8
8291800.0000.00000
2 1/2 NPT
65
170
93
0,4 … 8
8290900.0000.00000
G3
80
239,5
144
0,4 … 7
For further information www.imi-precision.com
Z
A
69
Technical data - Standard models Symbol
1 VALVES
• 2/2-way diaphragm valves
Easy to maintain
1
85500, 85540
VALVES
• 2/2-way piston valves DN 15 … 50, Flange connection, Pressure rating PN 40
Forced lift / damped operation Technical features Medium: Neutral gases and liquids (85500) Slightly aggressive, gases and liquids (85540) Flow direction: Fixed Operating pressure: 0 … 25 bar (0 … 362 psi)
Fluid temperature: -20°C … +90°C (-4°F … 194°F) Ambient temperature: -20°C … +50°C (-4°F … 122°F) Materials: Body: Cast steel Brass (85500), Stainless steel (85540) Seat seal: NBR Internal parts: Stainless steel, PTFE/Carbon
Technical features - Standard models Symbol
A P
Model Solenoid in V DC
Model Solenoid in V AC
Orifice (mm)
Flow Kv value *1) (m3/h)
Operating pressure *2) (bar)
8550200.9401.xxxxx
8550200.9404.xxxxx
15
4,4
0 … 25
8550300.9401.xxxxx
8550300.9404.xxxxx
20
7
0 … 25
8550400.9401.xxxxx
8550400.9404.xxxxx
25
10,5
0 … 25
8550500.8401.xxxxx
8550500.8404.xxxxx
32
25
0 … 25
8550600.8401.xxxxx
8550600.8404.xxxxx
40
27
0 … 25
8550700.8401.xxxxx
8550700.8404.xxxxx
50
43
0 … 25
xxxxx Please insert voltage and frequency codes
*1) Cv-value (US) ≈ kv value x 1,2 *2) For gases and liquid fluids up tobis 60 mm2/s (cSt)
Technical features - Standard models Model Solenoid in V DC
Model Solenoid in V AC
Orifice (mm)
Flow Kv value *1) (m3/h)
Operating pressure *2) (bar)
8554200.9401.xxxxx
8554200.9404.xxxxx
15
4,4
0 … 25
8554300.9401.xxxxx
8554300.9404.xxxxx
20
7
0 … 25
A
8554400.9401.xxxxx
8554400.9404.xxxxx
25
10,5
0 … 25
8554500.8401.xxxxx
8554500.8404.xxxxx
32
25
0 … 25
P
8554600.8401.xxxxx
8554600.8404.xxxxx
40
27
0 … 25
8554700.8401.xxxxx
8554700.8404.xxxxx
50
43
0 … 25
Symbol
70
For further information www.imi-precision.com
xxxxx Please insert voltage and frequency codes
*1) Cv-value (US) ≈ kv value x 1,2 *2) For gases and liquid fluids up tobis 60 mm2/s (cSt)
Solenoids
Electrical details for all solenoid systems
Voltage and Frequency Solenoid 9401/9404 *3) Code Voltage
Code Frequency
Voltage
Frequency
Power consumption Inrush- Holdingpower power
024
00
24 V DC
-
38 W
38 W
024
49
24 V AC
40 … 60 Hz
42 VA
42 VA
110
49
110 V AC
40 … 60 Hz
42 VA
42 VA
120
49
120 V AC
40 … 60 Hz
42 VA
42 VA
230
49
230 V AC
40 … 60 Hz
42 VA
42 VA
Design
DIN VDE 0580
Voltage range
±10%
Duty cycle
100% ED
Protection
EN 60529 IP65
Connector
Form A to DIN EN 175301-803 (included)
According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.
Voltage and Frequency Solenoid 8401/8404 024
00
24 V DC
-
40 W
40 W
024
49
24 V AC
40 … 60 Hz
45 VA
45 VA
110
49
110 V AC
40 … 60 Hz
45 VA
45 VA
120
49
120 V AC
40 … 60 Hz
45 VA
45 VA
230
49
230 V AC
40 … 60 Hz
45 VA
45 VA
*3)
Voltage (With the expection of solenoid 94XX up to 41 V a.c.).
Other functions and operating voltages available on request
Additional solenoid systems ATEX Category
Protection
Solenoid
Standard voltage
II 2GD
EEx me II T3 T 140°C
8441
24 V DC, 110 V AC, 230 V AC
II 3GD
Ex nA II T4 T 135°C *4)
9426
24 V DC, 110 V AC, 230 V AC
II 3GD
Ex nA II T4 T 135°C *4)
8426
24 V DC, 110 V AC, 230 V AC
II 2GD
Ex d II C T4 und T5 T 130°C resp. T 95°C
8920
24 V DC, 110 V AC, 230 V AC
II 2G II 2D
Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db
6240
24 V DC, 110 V AC, 230 V AC
II 2G II 2D
Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db
6246
24 V DC, 110 V AC, 230 V AC
Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids. *4) Only d.c., for a.c. solenoids with design inspection certificate acc. to category 2, e.g. xxxxxxx.8436.
85780 Optimised flange design Technical features
• DN 15 … 100, flange connection
Suitable for use in single-channel safety-related systems in accordance with DIN EN 61508 / 61511 up to and including SIL 2 and up to and including SIL 3 in multichannel systems. Flow direction: Fixed Medium: Neutral gases and liquids (air, water, gases according to DVGW data sheet G 260 with seat seal FPM, oils and other fluids on request)
VALVES
• 2/2-way diaphragm valves
1
Operating pressure: 0 … 25 bar (0 … 362 psi) Fluid temperature: -10°C … +60°C (14ºF … 140°F) Ambient temperature: -10°C … +50°C(14ºF … 122°F) Materials: Body: up to DN 50: Stainless steel (1.4408) from DN 65: Stainless steel (1.4581) Seat seal: NBR Internal parts: Stainless steel, PTFE/ Carbon
Technical features - Standard models Symbol
Model Solenoid in V DC
A P
Model Solenoid in V AC
Orifice (mm)
Flow Kv value *1) (m3/h)
Operating pressure *2) (bar)
8578200.8401.xxxxx
8578200.8404.xxxxx
15
3,7
0 … 25
8578300.8401.xxxxx
8578300.8404.xxxxx
20
5,6
0 … 25
8578400.8401.xxxxx
8578400.8404.xxxxx
25
7,8
0 … 25
8578500.8401.xxxxx
8578500.8404.xxxxx
32
18
0 … 25
8578600.8401.xxxxx
8578600.8404.xxxxx
40
24,4
0 … 25
8578700.8401.xxxxx
8578700.8404.xxxxx
50
31,8
0 … 25
8578800.9504.xxxxx
65
67
0 … 25
8578900.9504.xxxxx
80
94
0 … 25
8579000.9501.xxxxx
8579000.9504.xxxxx
100
144
0 … 25
71
8578800.9501.xxxxx 8578900.9501.xxxxx
xxxxx Please insert voltage and frequency codes. *1) Cv-value (US) ≈ kv value x 1,2. *2) For gases and liquid fluids up tobis 60 mm2/s (cSt).
Electrical details for all solenoid systems
Voltage and Frequency Solenoid 8401/8404 Code Voltage
Code Frequency
Voltage
Frequency
Power consumption Inrush- Holdingpower power
024
00
24 V DC
-
40 W
40 W
024
49
24 V AC *3)
40 … 60 Hz
45 VA
45 VA
110
49
110 V AC *3)
40 … 60 Hz
45 VA
45 VA
120
49
120 V AC *3)
40 … 60 Hz
45 VA
45 VA
230
49
230 V AC *3)
40 … 60 Hz
45 VA
45 VA
Design
DIN VDE 0580
Voltage range
±10%
Duty cycle
100% ED
Protection
EN 60529 IP65
Connector
Form A to DIN EN 175301-803 (included)
According to DIN VDE 0580 at a solenoid temperature of +20°C. At elevated temperatures, the power of the solenoid coil could be reduced by up to 30%.
Voltage and Frequency Solenoid 9501/9504 024
00
24 V DC
-
80 W
80 W
024
49
24 V AC *3)
40 … 60 Hz
89 VA
89 VA
110
49
110 V AC *3)
40 … 60 Hz
89 VA
89 VA
120
49
120 V AC *3)
40 … 60 Hz
89 VA
89 VA
230
49
230 V AC *3)
40 … 60 Hz
89 VA
89 VA
*3) A.c. only with rectifier plug.
Other functions and operating voltages available on request
Additional solenoid systems ATEX Category
Protection
Solenoid
Standard voltage
II 2GD
EEx me II T3 T 140°C
8441
24 V DC, 110 V AC, 230 V AC
II 2GD
Ex de IIC T4/T5 8900 Ex tD A21 IP65 T 130°C resp. T 95°C
24 V DC, 110 V AC, 230 V AC
II 2GD
Ex d IIC T4/T5 8920 Ex tD A21 IP65 T 130°C resp. T 95°C
24 V DC, 110 V AC, 230 V AC
II 3GD
Ex nA II T4 Ex tD A22 IP65 T 135°C
8426
24 V DC, 110 V AC, 230 V AC
II 2GD
Ex e mb II T3/T4 Ex tD A21 IP65 T 140°C
9540
24 V DC, 110 V AC, 230 V AC
II 2G II 2D
Ex eb mb IIC T3 Gb Ex mb tb IIIB T140°C Db
6240
24 V DC, 110 V AC, 230 V AC
II 2G II 2D
Ex eb mb IIC T4 Gb Ex mb tb IIIB T125°C Db
6246
24 V DC, 110 V AC, 230 V AC
Attention! The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.
For further information www.imi-precision.com
Solenoids
1
84500, 84520
VALVES
• Pressure actuated angle seat valves
Technical features
• 2/2 N/C, G1/2….G2
Medium: Neutral, gaseous and liquid fluids (84500) Agressives gaseous and liquid fluids (84520) Flow direction: Fixed Operating pressure: 0 … 16 bar (0 … 232 psi) See table Temperature: Fluid -10°C … +180°C (14°F … 356°F) max. Ambient -10°C … +60°C (14°F … 140°F) max.
Easy conversion to N/O or double acting without tools Materials: Body: Brass (84500) Stainless steel (84520) Seat seal: PTFE Internal parts: Brass, Stainless steel
72
Models Brass – For neutral, gases and liquids Symbol
For further information www.imi-precision.com
Z
A P
Model
Orifice (mm)
Port size
Kv value (m3/h)
Operating pressure (bar)
8450200.0000.00000
15
G1/2
4,8
0…16
8450300.0000.00000
20
G3/4
10
0…10
8450400.0000.00000
25
G1
14
0…10
8450500.0000.00000
32
G1 1/4
23
0…7
8450600.0000.00000
40
G1 1/2
30
0…4,5
8450700.0000.00000
50
G2
37
0…3
Stainless Steel – For agressive gaseous and liquid fluids Symbol
Z
A P
Model
Orifice (mm)
Port size
Kv value (m3/h)
Operating pressure (bar)
8452200.0000.00000
15
G1/2
4,8
0 … 16
8452300.0000.00000
20
G3/4
10
0 … 10
8452400.0000.00000
25
G1
14
0 … 10
8452500.0000.00000
32
G1/4
23,0
0…7
8452600.0000.00000
40
G1/2
30,0
0 … 4,5
8452700.0000.00000
50
G2
37,0
0…3
Suitable for contaminated fluids
V81, V82, V83 & V84 Bypass function for online servicing
Technical features
• G1/4, 1/4 NPT, G1/2, 1/2 NPT
Medium: Filtered, non-lubricated or dry compressed air, instrument air nitrogen and other nonflammable neutral dry fluids Operating pressure: V81, V82 & V83: 1 … 10 bar (145 psi) 2 … 8 bar (with 98025 Valves) V84: 12 bar (174 psi) 10 bar (145 psi) with CSA approval Additional filter: Installation of an in-line filter is recommended (in the direction of flow from the actuator to the RVM)
• International approvals • Three design options: Compact, semi-modular and modular • Aluminium or stainless steel construction For specific valve technical information please go to the relevant valve series pages.
1 VALVES
• Redundant valve manifold system
Outdoor installation
Ambient/Media temperature: V81,V82 & V83: Up to -40°C … +80°C V84: Up to -55°C to +80°C (-67°F … +176°F), See option selectors. Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below +2°C (35°F). For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP66 protection must be used!
1oo2, 2oo2 and 2oo3 increased safety & availability
Functionality options The RVM System is available in three functionality options, the selection of which will be dependent on the Safety Instrumented Function (SIF) that it is to be used within. 1oo2, 2oo2 double channel and uniquely 2oo3 triple channel systems are available.
73
Compact 1oo2 (V82 & V84)
Semi modular 1oo2 (V87 & V88)
Modular 1oo2 (with bypass) (V81 & V83)
1oo2 “Safety” Double channel redundant system
Compact 2oo2 (V82 & V84)
Semi modular 2oo2 (V87 & V88)
Modular 2oo2 (with bypass) (V81 & V83)
2oo2 “Availability” Double channel redundant system Redundancy for the process valve closure. Any one out of two solenoid valves needs to de-energise to ensure safety.
Compact 2oo3 (V82 & V84)
Semi modular 2oo3 (V87 & V88)
Modular 2oo3 (with bypass) (V81 & V83)
2oo3 “Safety and Availability” Triple channel redundant system Redundancy for the process valve closure. Any one out of two solenoid valves needs to de-energise to ensure safety.
For further information www.imi-precision.com
Redundancy for the process valve closure. Any one out of two solenoid valves needs to de-energise to ensure safety.
1
V81 & V82
VALVES
Option selector
V8˙˙˙˙˙˙˙4˙˙0000
74
For further information www.imi-precision.com
Models Modular with bypass Compact Valve function 1oo2 normally closed 2oo2 normally closed 2oo3 normally closed Port sizes G1/4 (Standard flow, 24011/24010) 1/4 NPT (Standard flow, 24011/24010) G1/2 (High flow, 98015/98025) 1/2 NPT (High flow, 98015/98025) Valve type Temperature 24011 series Aluminium -40°C … +60°C Stainless steel -40°C … +60°C Aluminium with -25°C … +70°C proximity sensor Stainless steel with -25°C … +70°C proximity sensor Aluminium -25°C … +80°C Stainless steel -25°C … +80°C 98015 series Aluminium -25°C … +60°C Stainless steel -25°C … +60°C Aluminium with -25°C … +60°C proximity sensor Stainless steel with -25°C … +60°C proximity sensor 24010 series Aluminium -25°C … +60°C Stainless steel -25°C … +60°C Aluminium with -25°C … +60°C proximity sensor Stainless steel with -25°C … +60°C proximity sensor 98025 series Aluminium -25°C … +60°C Stainless steel -25°C … +60°C
Substitute 1 2 Substitute 1 3 5 Substitute 11 12 23 24 Substitute V81 V82 011 010 022 020 033 030
Country of manufacture IMI internal use
-40°C … +80°C 2,5 … 10 bar
Silencers *1)
Temperature
Substitute
382402400
-20 … +60
FM/CSA
02
382512060
-20 … +60
FM/CSA
03
382602400
-20 … +60
FM/CSA
04
-20 … +60
FM/CSA
05
044
040
382712060 427002400
-40 … +65/55
ATEX/IECEX
08
053 064
050 060
427123050
-40 … +65/55
ATEX/IECEX
09
467002400
-40 … +70/40
ATEX/IECEX
14
467123050
-40 … +70/40
ATEX/IECEX
15
467202400
-40 … +70/40
ATEX/IECEX
16
467323050
-40 … +70/40
ATEX/IECEX
17
487202400
-40 … +50/40
ATEX/IECEX
18
487323050
-40 … +50/40
ATEX/IECEX
19
-40 … +70/55
ATEX/IECEX
55
-40 … +60
ATEX/IECEX
40
073 084 093
070 080 090
104
100
Instrinsically safe versions 213 224 233
210 220 230
244
240
313 324
310 320
Series 24010 2003 Series 98025*3) 2050
*1) Other indicators or silencers can be ordered separately *2) Temperature depending on Ex classification *3) Other solenoids and currents available on request
V81 Flow rates and valve combinations
Temperature (°C) Materials
Weight (kg)
Model
Flow direction (port to port)
-25 … +80°C -25 … +60°C
Aluminium Aluminium
9,5 kg 9,8 kg
V811120534**0000 V811240734**0000
-25 … +80°C -25 … +60°C
Aluminium Aluminium
9,6 kg 9,9 kg
V813120534**0000 V813240734**0000
-25 … +80°C -25 … +60°C
Aluminium Aluminium
15,7 kg 15,9 kg
V815120534**0000 V815240734**0000
1oo2 1 » 2 [l/min] *4) 2 » 3 [l/min] *5) 2oo2 1 » 2 [l/min] *4) 2 » 3 [l/min] *5) 2oo3 1 » 2 [l/min] *4) 2 » 3 [l/min] *5)
Standard flow systems (24011/24010) Bypass Operation mode mode 97109 2 x 24011 950 170 – 970 … 2200 97109 2 x 24011 950 240 – 950 … 2200 97109 4 x 24011 950 165 – 950 … 2200
High flow systems (98015/98025) Bypass Operation mode mode 97109 2 x 98015 1450 620 – 2800 … 4600 97109 2 x 98015 1450 720 – 2500 … 4600 97109 4 x 98015 1450 600 – 2500 … 4600
*4) Flow characteristics conforms to ISO6358 from port 1 (bypass valve) to port 2 (sub-base) [6 » 5 bar]. *5) Flow characteristics conforms to ISO6358 from port 2 (sub-base) to port 3 (sub-base or bypass valve) [10 » 0 bar].
V82 standard models
** Solenoid code.
Visual valve status indicators in stainless steel - included in the scope of supply
24011 series + 98015 *3)
** Solenoid code.
Port Valve size type 1oo2 (SIL 3) 1/4 NPT 2401109 1/2 NPT 9801595 2oo2 (SIL 2) 1/4 NPT 2401109 1/2 NPT 9801595 2oo3 (SIL 3) 1/4 NPT 2401109 1/2 NPT 9801595
Temperature / Pressure range
Exhaust guard - included in the -55°C … +80°C scope of supply Solenoids coil Temperature *2) EXStandard certificate (°C)
V81 standard models Port Valve size type 1oo2 (SIL 3) 1/4 NPT 2401109 1/2 NPT 9801595 2oo2 (SIL 2) 1/4 NPT 2401109 1/2 NPT 9801595 2oo3 (SIL 3) 1/4 NPT 2401109 1/2 NPT 9801595
Indicators *1) For V81
V82 Flow rates and valve combinations
Temperature (°C) Materials
Weight (kg)
Model
-25 … +80°C -25 … +60°C
Aluminium Aluminium
3,7 kg 4,4 kg
V821120504**0000 V821240704**0000
-25 … +80°C -25 … +60°C
Aluminium Aluminium
3,7 kg 4,4 kg
V823120504**0000 V823240704**0000
-25 … +80°C -25 … +60°C
Aluminium Aluminium
8,2 kg 9,3 kg
V825120504**0000 V825240704**0000
Flow direction (port to port) 1oo2 1 » 2 [l/min] *6) 2 » 3 [l/min] *7) 2oo2 1 » 2 [l/min] *6) 2 » 3 [l/min] *7) 2oo3 1 » 2 [l/min] *6) 2 » 3 [l/min] *7)
Standard flow systems (24011/24010) 2 x 24011 170 1000 2 x 24011 250 710 4 x 24011 190 710
High flow systems (98015/98025) 2 x 98015 750 3400 2 x 98015 1050 2690 4 x 98015 740 2420
*6) Flow characteristics conforms to ISO6358 from port 1 to port 2 (sub-base) [6 » 5 bar]. *7) Flow characteristics conforms to ISO6358 from port 2 (sub-base) to port 3 (sub-base) [10 » 0 bar].
V83 & V84
1
Option selector
Valve type
Substitute 3 4 Substitute 1 3 5 Substitute 11 12 23 24
Solenoid Voltage Protection
01 02 03 04 05 06 07 08 09 10 22 24 28 30 31 32 42 43 44
24V d.c. 24V d.c. 110V a.c. 24V d.c. 24V a.c. 125V d.c.
M20x1,5 1/2 NPT 1/2 NPT 1/2 NPT M20x1,5 1/2 NPT
21 25 26 29 33 45
24 V d.c. 24 V d.c. 230 V a.c. 230 V a.c. 24 V d.c. 24 V d.c. 230 V a.c. 230 V a.c. 110V a.c. 125V d.c.
M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT M20x1,5 1/2 NPT
12 13 14 15 17 18 19 20 39 41
1/2 NPT M20x1,5
Note; Please advise when ordering if CSA certification is required.
27 46
Substitute 2 4 Substitute 2 4 0
Flow rates and valve combinations Flow direction (port to port)
Standard flow systems Bypass mode Operation mode
High flow systems Bypass mode Operation mode
1oo2
97109
2 x Y*13ANPH*BS
97109
2 x Y*13AMMH*BS
1 » 2 *10) [l/min]
950
330
1450
740
2 » 3 *11) [l/min]
–
1740 … 2200
–
3200 … 4600
2oo2
97109
2 x Y*13ANPH*BS
97109
2 x Y*13AMMH*BS
1 » 2 *10) [l/min]
950
490
1450
810
2 » 3 *11) [l/min]
–
1640 … 2200
–
2500 … 4600
2oo3
97109
4 x Y*13ANPH*BS
97109
4 x Y*13AMMH*BS
1 » 2 *10) [l/min]
950
320
1450
720
2 » 3 *11) [l/min]
–
1640 … 2200
–
2500 … 4600
*10) Flow characteristics conforms to ISO6358 from port 1 (bypass valve) to port 2 (sub-base) [6 » 5 bar]. *11) Flow characteristics conforms to ISO6358 from port 2 (sub-base) to port 3 (sub-base or bypass valve) [10 » 0 bar].
For further information www.imi-precision.com
M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 M 20 x 1,5 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT M20x1,5 M20x1,5 1/2 NPT 1/2 NPT 1/2 NPT M20x1,5 1/2 NPT 1/2 NPT 1/2 NPT
110V a.c. 24V d.c.
Silencers*9) Temperature Exhaust guard (standard) -55°C … +80°C Manifold material Stainless steel Aluminium Bypass valve (V83) Temperature Stainless steel -40°C … +60°C Stainless steel -25°C … +80°C No bypass (V84) *8) other indicators or plugs can be ordered separately. *9) other silencers can be ordered separately.
Substitute
24 V d.c. 24 V d.c. 24 V d.c. 230 V a.c. 230 V a.c. 24 V d.c. 24 V d.c. 24 V d.c. 230 V a.c. 230 V a.c. 24V d.c. 24V d.c. 24V d.c. 125V d.c. 110V a.c. 110V a.c. 125V d.c. 110V a.c. 120V a.c.
Temperature / Pressure range -40°C … +80°C 2,5 … 10 bar
75
Standard flow YX13ANPH1BS Exia Y013ANPH1BS Exd YZ13ANPH1BS Exmbe Y013ANPH1MS Exd YZ13ANPH1MS Exmbe YX13ANPH2BS Exia Y013ANPH2BS Exd YZ13ANPH2BS Exmbe Y013ANPH2MS Exd YZ13ANPH2MS Exmbe Y013ANPH1BS-2W Exd Y013ANPV1BS-2W Exd Y013ANPH2BS-2W Exd Y013ANPH2ES Exd Y013ANPH2JS Exd Y013ANPH2JS Exd YZ13ANPH2ES Exmbe YZ13ANPH2JS Exmbe YZ13ANPH2TS Exmbe Standard flow (PBMR) Y013PNPH1BS Exd Y013PNPH2BS Exd Y013PNPH2JS Exd Y013PNPH2BS-2W Exd Y013PNPH1BS-2W Exd Y013PNPH2ES Exd High flow Y013AMMH1BS Exd YZ13AMMH1BS Exmbe Y013AMMH1MS Exd YZ13AMMH1MS Exmbe Y013AMMH2BS Exd YZ13AMMH2BS Exmbe Y013AMMH2MS Exd YZ13AMMH2MS Exmbe Y013AMMH1JS Exd Y013AMMH2ES Exd High flow (PBMR) Y013PMMH2JS Exd Y013PMMH1BS Exd
Cable Entry
Country of manufacture IMI internal use Indicators*8) For V83 Visual valve status indicators in stainless steel - included in the scope of supply
VALVES
V8˙˙˙˙˙˙˙˙000000
Models Modular with bypass Compact Valve function 1oo2 normally closed 2oo2 normally closed 2oo3 normally closed Port sizes G1/4 (Standard flow) 1/4 NPT (Standard flow) G1/2 (High flow) 1/2 NPT (High flow)
1
V81, V82, V83 & V84
VALVES
Accessories Standard (Included in the scope of supply) Exhaust guard *12)
Visual indicators (stainless steel) only for V81
0613422 (G 1/4, 1/4 NPT)
74749-61 (G 1/4)
â&#x20AC;&#x201C;
74749-60 (1/4 NPT)
0613423 (G 1/2, 1/2 NPT)
â&#x20AC;&#x201C;
Other silencers, plastic indicator and plugs (can be ordered separately) Silencer (stainless steel) *13)
Silencer (plastic) *13)
Visual indicators (plastic) Adaptor
Plug plus Sealing washer
76
For further information www.imi-precision.com
0014613 (G 1/4)
M/S2 (G 1/4)
5VS-212-000 (1/8 NPT)
0663943 (G 1/4, stainless steel)
0613678 (1/4 NPT)
C/S2 (1/4 NPT)
Adapter (1/8 NPT to 1/4 NPT) *14)
0682082 (1/4 NPT, stainless steel)
0014813 (G 1/2)
M/S4 (G 1/2)
0613659 (stainless steel)
0660835 (plastic) Sealing washer *15)
0613679 (1/2 NPT)
C/S4 (1/2 NPT)
*12) For outdoors use ~ 0,2 (bar). *13) For indoors use. *14) Must be ordered separately. *15) Must be ordered separately for G thread only.
80400 Suitable for installation in extreme low temperature, outdoor and off shore applications
Technical features Medium: Filtered, non-lubricated compressed air, instrument air, nitrogen or other nonflammable, neutral dry fluids Operating pressure: 0 … 10 bar (0 … 145 psi) Pilot pressure: 2 … 10 bar (29 … 145 psi) (≥ operating pressure) Fluid/Ambient temperature: -60°C … 80°C (-76°F … 176°F)
• 1/2 … 1 1/2 NPT or G1/2 … G1 1/2
Material: Housing, flange and inner parts: stainless steel 1.4404 (316 L) * Dynamic seals: PUR Static seals: PUR and NBR *C racking-resistant for use in H2S-contaminated environments (DIN EN ISO 15156-3:2005).
VALVES
• 3/2 way poppet valve pneumatically actuated
1
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F) For outdoor installation please protect all connections against the penetration of moisture! Please contact IMI Precision Engineering for operational conditions below -55°C
SIL2 @ HFT=0 SIL3 @ HFT=1
Symbol
77
Technical data Model
Port size 1
3
Flow *2) 1 » 2 2»3 (l/min) (l/min)
8040005
1/2 NPT
1/2 NPT
3/4 NPT
15
6700
7600
17200
19800
8040015
3/4 NPT
3/4 NPT
1 NPT
20
11500
14000
29000
35000
8040025
1 NPT
8040035 V-32C-L-F1 1/2 NPT
1
3
Flow *1) 1 » 2 2»3 (l/min) (l/min)
1 NPT
1 1/4 NPT
25
13900
14700
32300
39600
1 1/2 NPT
1 1/2 NPT
30
24700
30500
56800
72600
8040055
G1/2
G1/2
G3/4
15
6700
7600
17200
19800
8040065
G3/4
G3/4
G1
20
11500
14000
29000
35000
8040075
G1
G1
G1 1/4
25
13900
14700
32300
39600
8040085
G1 1/2
G1 1/2
G1 1/2
30
24700
30500
56800
72600
Flow conducted according to ISO 6358. In order to ensure full flow and proper function make sure that sufficient pressure supply with feed pipe diameters according to the port size is available. *1) Inlet pressure 6 bar, outlet pressure 5 bar. *2) Inlet pressure 10 bar, outlet pressure 0 bar.
For further information www.imi-precision.com
2
2
Nominal diameter (mm)
1
VALVES
78
2 I/P & E/P Converters
Reliable, rugged, certified control Explosion Proof
The Only ATEX IS Fail Freeze I/P
Failsafe
<0.13W Consumption
2
Fast Find Guide
I / P & E / P C ON V E R T E R S
140 Series
422 Series
Closed loop I/P Failsafe
0.2 … 1 bar ALU, ZI
Page 81
0.2 … 1 bar ZI
80
For further information www.imi-precision.com ALU
Aluminium
422 IS Series
Closed loop I/P Fail Freeze
ZI
Zinc Die-casting
VP10 Series
Closed loop I/P Fail Freeze
Page 82
0.2 …1 bar Zi
100X Series
Open loop I/P
Page 83
0.2 … 8 bar ZI
220 Series
Open loop I/P
Page 84
0 … 1 bar ZI
Page 85
0 … 1 bar ZI
Page 86
140 Failsafe Series Explosion Proof I/P
Technical features Medium: Oil free, dry air, min filtered to 50 µm; internal in-built air filter Output pressure: 0,2 … 1 bar (3 … 15 psi) 0,2 … 2 bar (3 … 30psi) Supply pressure: 1,2 … 10,3 bar (18 … 150 psi) Response time: < 1 second (from 0 … 90% or 90 … 10% of output pressure into a 0,5 litre load) Temperature sensitivity: Typically < 0,06% span/°C between -40°C … +85°C (-40°F … +185°F)
• G1/4 or 1/4 NPT • Tight Shut Off setting
Linearity independent: Typically <0.1%, guaranteed <0.2% Hysteresis independent: Typically <0.1%, guaranteed <0.2% Supply sensitivity: < 0,1 z of span for full supply pressure range Operating temperature: -40°C … +85°C (-40°F … +185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
FM
I.P. Rating: IP66, NEMA Type 4X Materials: Body: aluminium and zinc diecasting Diaphragms: NBR Black epoxy powder coating standard
APPROVED
I / P & E / P C ON V E R T E R S
• Current to pressure (I/P) electronic converter
2
Technical data - standard models Symbol
Certification
Port size
Output pressure
Conduit Entry
EX14001BJ4LE2
Cenelec only
G1/4
0,2 … 1 bar
M 20 x 1,5
EX14001BK4EE1
ATEX: Ex ia, Exd, Exn FM/CSA:I.S., N.I.
1/4 NPT
0,2 … 1 bar
1/2 NPT
81
Model Multi certified units only – IS/Type N/Exd
Options available: Output pressure monitoring gauge.
Input Signal
4 … 20 mA (two wire) Terminal voltage < 6,5 V at 20 mA
Failure Mode
Pressure falls to below 15 mbar (0,2 psi) in < 2 sec when input signal fails
Overload Protection
100 mA max overload current
Connections
1/2” NPT or M20; internal terminal block with capacity up to 2,5 mm2 conductor
Option selector Output pressure bar (psi)
EX140˙˙˙˙4˙˙˙ Substitute
Certification Triple certification/ triple agency
0,2 … 1 (3 … 15)
01
Cenelec only (M20x1,5)
0,4 … 2 (6 … 30)
02
Conduit Entry
Unit of Pressure
Substitute
1/2 NPT
Substitute E1 E2 Substitute E
Bar
B
M 20 Cenelec Only
Psi
P
Ports
KPa
K
G1/4
J
Kg/cm2
G
1/4 NPT
K
L Substitute
For further information www.imi-precision.com
Electrical parameters
2
422 Fail Freeze Series Fail Freeze I/P
I / P & E / P C ON V E R T E R S
• Current to pressure (I/P)
Technical features
• 1/4 NPT
Medium: Oil free, dry air, filtered to 5 µm Output pressure: 0,2 … 1 bar (3 … 15psi) Supply pressure: at least 0,7 bar (10 psi) above maximum required output pressure maximum 3 bar gauge Flow capacity: Up to 300NL/min Response time: < 8 sec (typically < 3 sec) from 10% … 90% of output pressure into a 0,5 litre volume < 8 sec (typically < 3 sec) from 90% … 10% of output pressure into a 0,5 litre volume Linearity: ≤0,5% of Span
• Hold last pressure on failure of signal
Hysteresis: ≤0,5% of Span Temperature sensitivity: Typically < 0,034% span/°C between -10°C and +60°C (+14°F and +140°F) Supply sensitivity: < 0,1% of span for full supply pressure range Operating temperature: -20°C … +70°C (-4°F … +158°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
I.P. Rating: IP65 Materials: Body: zinc diecasting passivated and epoxy painted Cover: Glass renforced PA Diaphragms: NBR
82
Technical data - standard models Symbol
Model
Port
Output pressure
For further information www.imi-precision.com
AC2100
1/4 NPT
0,2 - 1 bar
AC0100
1/4 NPT
3 - 15 psi
AC0138X
1/4 NPT
0,2 - 1,0 Kg/cm2
For other port sizes or options please contact your sales representative.
Electrical parameters Input Signal
4 - 20 mA (two wire). Terminal voltage typically 7,5 V at 20 mA
Failure Mode
Output pressure held at previous value when input signal fails; drift rate 0,02% in 30 seconds
Overload protection
100 mA max. overload current. Unit unaffected by short duration reverse current
Connections
30 mm square connector provided (DIN 43650, form A) mountable in 4 directions
Span/Zero
Independently adjustable up to 20% output range
422 IS Fail Freeze Series Technical features
• G1/4 or 1/4 NPT
Medium: Oil free, dry air, filtered to 5 µm Output pressure: 0,2 … 1 bar (3 … 15psi) Supply pressure: at least 0,7 bar above maximum required output pressure maximum 4 bar gauge Flow capacity: Up to 250 Nl/min I.P. Rating: IP65 with piped exhaust Linearity: ≤0,5% of Span Hysteresis: ≤0,5% of Span
I / P & E / P C ON V E R T E R S
• Current to pressure (I/P) Converter • The only ATEX IS Fail Freeze I/P on the market
2
ATEX IS I/P Converter EMC Compatibility: Compliant and CE marked in accordance with the EC Directive 2004/108/EC tested to BS EN 61000-6-2:2005 BS EN 61000-6-4:2007+ A11:2011 Ambient/Media temperature: -10°C … +70°C Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Materials Body: zinc diecasting passivated nd epoxy painted Cover: Glass reinforced PA Diaphragms: NBR
Technical data Symbol
Model
Port size
Output pressure
AC301PJ1
G1/4
3 … 15 psi
AC301PK1
1/4 NPT
3 … 15 psi
G1/4
0,2 … 1 bar
1/4 NPT
0,2 … 1 bar
83
AC301BJ1 AC301BK1
Electrical parameters 4 … 20 mA (two wire). Terminal voltage typically < 11 V at 20 mA
Failure Mode
Output pressure held at previous value when input signal fails; drift rate ≤ 0,2% of span in 5 minutes
Overload protection
30 mA max. overload current. Unit unaffected by reverse current
Connections
30 mm square connector provided (DIN 43650, form A) mountable in 4 directions
Span/Zero
Independently adjustable up to 15% output range
For further information www.imi-precision.com
Input Signal
Certification Certification Agency
ATEX Intrinsically safe
IECEx Intrinsically safe
Sira
II 1G Sira 03ATEX2007X
IECEx SIR 11.0095X
Ex ia IIC T4 Ga (Ta = -40 … +80°C)
Ex ia IIC T4 Ga (Ta = -40 … +80°C)
Ui = 28 V d.c. Ii = 110 mA Pi = 0,8 W Ci = 5 nF Li = 0,24 mH
Ui = 28 V d.c. Ii = 110 mA Pi = 0,8 W Ci = 5 nF Li = 0,24 mH
1G
Option selector Pressure range
AC301˙˙˙ Substitute
Special notes
Substitute
3 … 15 psi
P
Standard exhaust
0
0,2 … 1 bar
B
Capture bleed
1
Port sizes
Substitute
Junction box & C/B
2
G 1/4
J
1/4 NPT
K
2
VP10 Series
I / P & E / P C ON V E R T E R S
• Proportional pressure control valves (I/P)
Reliable, rugged, open loop control
Technical features Medium: Oil free, dry air, filtered to 5 µm Output pressure: 0,2 … 1 bar (2,9 … 14,5 psi) 0,2 … 6 bar (2,9 … 87 psi) 0,2 … 8 bar (2,9 … 116 psi) Supply pressure: At least 0,7 bar (10 psi) above maximum required output pressure. Up to 2 bar(29 psi) instruments: max 5 bar (72,5 psi). Up to 8 bar (116 psi) instruments: max 10 bar (145 psi). Response Time: < 0,35 seconds for 10 … 90% or 90 … 10% of output pressure into a 10cc load (1 bar (14,5psi) range instruments)
• G1/4
Temperature sensitivity: < 0,1% of span/°C between -40°C … +85°C (-40°F … +185°F) Supply sensitivity: < 0,075% span output change per % supply pressure change Operating temperature: -40°C … +85°C (-40°F … +185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C(+35°F)
I.P. Rating: IP65 in normal operation Materials: Body: Passivated zinc die-casting, epoxy painted Cover: Glass reinforced PA Diaphragms: NBR
84
Technical data - standard models Symbol
For further information www.imi-precision.com
Model
Port size
Flow (l/min)
Control signal
Output pressure (bar)
VP1001BJ400A00
G1/4
300
4 … 20 mA
0,2 … 1
VP1006BJ401A00
G1/4
300
4 … 20 mA
0,2 … 6
VP1008BJ401A00
G1/4
300
4 … 20 mA
0,2 … 8
Electrical parameters Input Signal
1 … 4 bar: 2 wire 4 … 20 mA 6 … 8 bar: 3 wire 4 … 20 mA +12 … 24 V
Failure Mode
Output pressure falls to zero signal state when electrical supply fails
Connections
30 mm square connector provided (DIN 43650, form A) mountable in four orientations
Option selector Pressure range
VP10˙˙˙˙˙0˙A00 Substitute
Power supply
Substitute
0,2 … 1 bar / 3 … 15 psi
01
None requied
0
0,2 … 2 bar / 3 … 30 psi
02
1
0,2 … 4 bar / 3 … 60 psi
04
12 / 24 V (Required for 6 & 8 bar units)
0,2 … 6 bar / 3 … 90 psi
06
Input signal
0,2 … 8 bar / 3 … 120 psi
08
0 … 10 V / 1 … 10 V
Unit of Measure
Substitute
4 … 20 mA
Substitute 1 4
bar
B
Port size
Substitute
psi
P
1/4 NPT
K
1/4 BSP
J
100X Series Reliable, rugged, certified control • Proportional pressure control valves (I/P) • 1/4 NPT
I / P & E / P C ON V E R T E R S
Technical features Medium: Oil free, dry air, filtered to 5 µm Output pressure: 0,2 … 1 bar (2,9 … 14,5 psi) 3 … 15 psi Supply pressure: At least 0,7 bar (10 psi) above maximum required output pressure. max 5 bar (72,5 psi) Flow capacity: > 300Nl/min forward & relief flow Air consumption: up to 1 bar (15 psi): 2,8 Nl/min Response Time: < 0,35 seconds for 10 …. 90% or 90 … 10% of output pressure into a 10cc load (1 bar (14,5psi) range instruments)
Temperature sensitivity: < 0,1% of span/°C between -40°C … +85°C (-40°F … +185°F) Supply sensitivity: < 0,075% span output change per % supply pressure change Operating temperature: -40°C … +85°C (-40°F … +185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
I.P. Rating: IP65 in normal operation Materials: Body: Passivated zinc die-casting, epoxy painted Cover: Glass reinforced PA Diaphragms: NBR
85
Technical data - standard models Symbol
Port
Output pressure
Input Signal
400100R
1/4 NPT
3 … 15 psi
4 … 20 mA
402100R
1/4 NPT
0,2 … 1 bar
4 … 20 mA
490100R
1/4 NPT
3 … 15 psi
4 … 20 mA
x
492100R
1/4 NPT
0,2 … 1 bar
4 … 20 mA
x
Electrical parameters Input Signal
1 … 4 bar: 2 wire 4 … 20 mA
Failure Mode
Output pressure falls to zero signal state when electrical supply fails
Connections
30 mm square connector provided (DIN 43650, form A) mountable in four orientations
Certification Typ 100X Intrinsically Safe Sira 02ATEX2002X SIRA (CENELEC ATEX approved) to EN60079
Ex ia IIC T4 Ga (Ta = -40° to +80 °C) Ui = 28 V, Ii = 59 mA, Pi = 0.633 W Ci = 0 Li = 10 mH
II 1G
ATEX intrinsically safe
For further information www.imi-precision.com
Model
For other port sizes or options please contact your sales representatives
Certification
2
2
220 Series < 6 milliwatts of power
I / P & E / P C ON V E R T E R S
• High performance OEM I/P
Technical features
• Extremely low power consumption
Medium: Oil free, dry air, filtered to 5 µm Output pressure: 0 … 1 bar (0 … 15 psi) Supply pressure: At least 0,4 bar (10 psi) above maximum required output pressure, maximum 10 bar (145 psi) gauge Air consumption: 1,5 Nl/min typical Linearity: ≤ 2,0% of span Hysteresis & deadband: Typical ≤ 0,35% of span Response time: < 650 ms 10 … 90% into a 3cc volume ≤ 300 ms 90 … 10% into a 3cc volume
• Minimal temperature and orientation effect • Compact and rugged • Patented technology • Fast response • Customisable to OEM applications
Temperature sensitivity: Typical 0,2% span/°C between -40°C and +85°C Air supply sensitivity: Typical < 1,5% of span for full supply pressure range Vibration effect: <2% of span for vibration level up to, 2g 20 … 150 Hz in any orientation I.P. Rating: IP 30 as standard or customised to suit customer requirements Mounting Position: Any, to suit customer requirements Connections: Customised to suit customer requirements Ambient/Media temperature: -40°C … +85°C (-40°F … 185°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C(+35°F)
86
Electrical parameters
For further information www.imi-precision.com
Input Signal
0 … 1,7 mA - terminal voltage is 3,11 V at 1,7 mA
Loop Resistance
1,8 kΩ
Input Impedance
3,1 … 3,2 V at 1,7 mA
Failure Mode
Output pressure falls to Zero setting on loss of signal
Connections
Customised to suit customer requirements
Ordering information Option to special order Performance parameters tuned to specific requirements Ported or manifold mount base designed to application requirements Optional enclosures Application specific calibration and set-up
3 Pressure Switches & Sensors Gold plated contacts Off line Programming
Stainless steel housing
ATEX
3
Fast Find Guide
P R E S S U R E S WI T C H E S & S E N S OR S
Electro-mechanical Pressure Switches 18D ATEX
18D Hydraulic ATEX
G1/4 or Flange
-1 … 30 bar ALU
20D Allfluid ATEX
G1/4 or Flange
Page 89
5 … 420 bar ALU St
Page 91
-1 … 63 bar ALU
Electronic Pressure Switch 33D Hydraulic/ Allfluid G1/4 or Flange
0 … 630 bar ALU SS
Page 94
Electronic Pressure Sensor 18S Allfluid G1/4
88 0 … 800 bar SS
Page 96
For further information www.imi-precision.com ALU
Aluminium
SS
Stainless Steel
20D Hydraulic ATEX
G1/2
St
Steel
G1/4
Page 92
5 … 400 bar ALU
Page 93
18D ATEX Technical features
• -1 … 30 bar G1/4 & Flanged
For Ex applications conforming to Zone 2 (gases): II3G Ex nAC IIC T6 X and Zone 22 category (dusts): II3D Ex tD A22 IP65 (e.g. IP67) T80°C X. Medium: For neutral, non-inflammable gases and fluids Operation: Diaphragm Operating pressure: -1 … 30 bar (-14 … 435 psi)
Degree of protection: IP65 for DIN EN 175301-803 (DIN 43650) form A IP67 for M12 x 1 Electrical connection: DIN EN 175301-803 (DIN 43650) form A or M12 x 1 IEC 947-5-2 Fluid/Ambient temperature: 0°C … +80°C (0°F … +176°F) (FPM)
Microswitch with gold plated contacts
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Materials: Housing: Aluminium Sealing: FPM/brass O-ring: NBR
Symbol
89
Electrical connection acc. to DIN EN 175301-803, form A - connector included in the scope of supply. The Ex approval refers to the pressure switch in combination with the supplied plug. Pressure range *1) (bar)
Switching pressure difference Lower range Upper range (bar) (bar)
Max. Over pressure *2) (bar)
Switching cycles (1/min)
Materials Pressure sensor housing
Sealing
Port size
0880180
-1 … 0
0,15
0,18
80
100
Aluminium
FPM/BR/NBR
G1/4
0880280
0,2 … 2
0,20
0,35
80
100
Aluminium
FPM/BR/NBR
G1/4
0880380
0,5 … 8
0,35
0,85
80
100
Aluminium
FPM/BR/NBR
G1/4
0880480
1 … 16
0,40
1,20
80
100
Aluminium
FPM/BR/NBR
G1/4
0880680
1 … 30
1
5
80
100
Aluminium
FPM/BR/NBR
G1/4
0881180
-1 … 0
0,15
0,18
80
100
Aluminium
FPM/BR/NBR
Flange
0881280
0,2 … 2
0,20
0,35
80
100
Aluminium
FPM/BR/NBR
Flange
0881380
0,5 … 8
0,35
0,85
80
100
Aluminium
FPM/BR/NBR
Flange
0881480
1 ... 16
0,40
1,20
80
100
Aluminium
FPM/BR/NBR
Flange
0881680
1 ... 30
1
5
80
100
Aluminium
FPM/BR/NBR
Flange
For further information www.imi-precision.com
Model
*1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values. BR = brass
3 P R E S S U R E S WI T C H E S & S E N S OR S
• Electro-mechanical pressure switch
Microswitch approved by UL and CSA
3
18D ATEX
P R E S S U R E S WI T C H E S & S E N S OR S
Electrical connection M12x1 acc. to IEC 947-5-2 - connector are not included in delivery, max. allowable voltage 30 V. The pressure switch will loose the Ex approval when using other connectors than those listed in the data sheet. Symbol
Model
Pressure range *1) (bar)
Switching pressure difference Lower range Upper range (bar) (bar)
Max. Over pressure *2) (bar)
Switching cycles (1/min)
Materials Pressure sensor housing
Sealing
Port size
0880181
-1 ... 0
0,15
0,18
80
100
Aluminium
FPM/BR/NBR
G1/4
0880281
0,2 ... 2
0,20
0,35
80
100
Aluminium
FPM/BR/NBR
G1/4
0880381
0,5 ... 8
0,35
0,85
80
100
Aluminium
FPM/BR/NBR
G1/4
0880481
1 ... 16
0,40
1,20
80
100
Aluminium
FPM/BR/NBR
G1/4
0880681
1 ... 30
1
5
80
100
Aluminium
FPM/BR/NBR
G1/4
0881181
-1 ... 0
0,15
0,18
80
100
Aluminium
FPM/BR/NBR
Flange
0881281
0,2 ... 2
0,20
0,35
80
100
Aluminium
FPM/BR/NBR
Flange
0881381
0,5 ... 8
0,35
0,85
80
100
Aluminium
FPM/BR/NBR
Flange
0881481
1 ... 16
0,40
1,20
80
100
Aluminium
FPM/BR/NBR
Flange
0881681
1 ... 30
1
5
80
100
Aluminium
FPM/BR/NBR
Flange
*1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values.
90
Accessories for use with all 18D series switches
For further information www.imi-precision.com
Pressure port reducing nipple
Surge damper
Cover (via adjustment screw)
Connector
Connector M 12 x 1 90°
0574767 (brass)
0574773 (brass)
0554737
0570110
0523058 (2 m cable, 4-core)
0550083 (Stainless steel)
0553258 (Stainless steel)
0523053 (5 m cable, 4-core)
Connector M 12 x 1 straight
0523056 (90° without cable)
0523057 (2 m cable, 4-core) 0523052 (5 m cable, 4-core)
0523055 (without cable)
18D Hydraulic ATEX
Microswitch approved by UL and CSA
Technical features
• 5 ... 420 bar, G1/4 & Flange
For Ex applications conforming to Zone 2 (gases): II3G Ex nAC IIC T6 X and Zone 22 category (dusts): II3D Ex tD A22 IP65 (e.g. IP67) T80°C X. Medium: For neutral, self lubricating fluids,e.g. hydraulic oil, lube oil, light fuel oil Operation: Softseal piston
Microswitch with gold plated contacts
Degree of protection: IP65 for DIN EN 175301-803 (DIN 43650) form A IP67 for M12 x 1 Electrical connection: DIN EN 175301-803 (DIN 43650) form A or M12 x 1 IEC 947-5-2 Fluid/Ambient temperature: 0°C ... +80°C (0°F ... +176°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Materials: Housing: Aluminium/Steel Sealing: PTFE/NBR For accessories - please see page 76
Electrical connection acc. to DIN EN 175301-803, form A - connector included in the scope of supply. The Ex approval refers to the pressure switc h in combination with the supplied plug. Symbol
Switching pressure difference Lower range Upper range (bar) (bar)
Max. Over pressure *2) (bar)
Switching cycles (1/min)
Materials Pressure sensor housing
Sealing
Port size
0882180
5 ... 70
10,5
15
400
100
AL/Steel
PTFE/NBR
G1/4
0882280
10 ... 160
11
17
400
100
AL/Steel
PTFE/NBR
G1/4
0882380
25 ... 250
13
21
400
100
AL/Steel
PTFE/NBR
G1/4
0882480
40 ... 420
17
38
600
100
AL/Steel
PTFE/NBR
G1/4
0883180
5 ... 70
10,5
15
400
100
AL/Steel
PTFE/NBR
Flange
0883280
10 ... 160
11
17
400
100
AL/Steel
PTFE/NBR
Flange
0883380
25 ... 250
13
21
400
100
AL/Steel
PTFE/NBR
Flange
0883480
40 ... 420
17
38
600
100
AL/Steel
PTFE/NBR
Flange
*1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values.
Electrical connection M12 x 1 acc. IEC 947-5-2 - connector are not included in delivery, max. allowable voltage 30 V max.The pressure switch will loose the Ex approval when using other connectors than those listed in the data sheet. Symbol
Model
Pressure range *1) (bar)
Switching pressure difference Lower range Upper range (bar) (bar)
Max. Over pressure *2) (bar)
Switching cycles (1/min)
Materials Pressure sensor housing
Sealing
Port size
0882181
5 ... 70
10,5
15
400
100
AL/Steel
PTFE/NBR
G1/4
0882281
10 ... 160
11
17
400
100
AL/Steel
PTFE/NBR
G1/4
0882381
25 ... 250
13
21
400
100
AL/Steel
PTFE/NBR
G1/4
0882481
40 ... 420
17
38
600
100
AL/Steel
PTFE/NBR
G1/4
0883181
5 ... 70
10,5
15
400
100
AL/Steel
PTFE/NBR
Flange
0883281
10 ... 160
11
17
400
100
AL/Steel
PTFE/NBR
Flange
0883381
25 ... 250
13
21
400
100
AL/Steel
PTFE/NBR
Flange
0883481
40 ... 420
17
38
600
100
AL/Steel
PTFE/NBR
Flange
*1) Setpoints should be ideally in the middle of the switching pressure range. Reference pressure = atmospheric pressure. Switching pressure must not exceed the indicated values. *2) Max. values.
For further information www.imi-precision.com
Pressure range *1) (bar)
91
Model
P R E S S U R E S WI T C H E S & S E N S OR S
• Electro-mechanical pressure switch
3
3
20D Allfluid ATEX
Microswitch with gold plated contacts
P R E S S U R E S WI T C H E S & S E N S OR S
• Electro-mechanical pressure switch
Technical features
• -1 … 63 bar, G1/2
For Ex zones 1 and 2 (gases) category II2G type of protection Ex db eb IIC T6 For Ex zones 21 and 22 (dusts) category II2D type of protection Ex tb IIIC T80°C IP65
Degree of protection: IP65 (DIN 40050) Fluid/Ambient temperature: -10°C … +75°C (+14°F … 167°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Medium: For neutral, non-inflammable gases and fluids Operation: Softseal piston Stainless steel bellow
Materials: Housing: Aluminium diecast Sensor: Brass or Stainless steel (1.4404) Sealing: Stainless steel-bellows
Fixed switching pressure difference Symbol
92
Model
Operating pressure *1) (bar)
Over pressure *2) (bar)
Switching pressure difference (typical) Lower range Upper range (bar) (bar)
Pressure sensor material
Port size
Sensor
1840115
-1 ... 0
10
0,20
0,23
1.4404
G1/2
B
1840215
-1 ... 1
10
0,20
0,25
1.4404
G1/2
B
1840415
-1 ... 2,5
10
0,22
0,26
1.4404
G1/2
B
1841115
0,05 ... 1
10
0,16
0,18
1.4404
G1/2
B
1841215
0 ... 1,6
10
0,16
0,20
1.4404
G1/2
B
1841415
0,5 ... 4
20
0,50
0,55
1.4404
G1/2
B
1841515
0,5 ... 6
20
0,60
0,70
1.4404
G1/2
B
1841615
0,5 ... 10
20
0,70
0,90
1.4404
G1/2
B
1841715
1 ... 16
50
1,00
1,40
1.4404
G1/2
F
1841815
1 ... 25
50
1,30
1,80
1.4404
G1/2
F
1841915
5 ... 63
150
2,00
5,00
1.4404
G1/2
H
For further information www.imi-precision.com
Adjustable switching pressure difference Symbol
Model
Operating pressure *1) (bar)
Over pressure *2) (bar)
Switching pressure difference (typical) Lower range Upper range minimal maximal (bar) (bar) (bar)
Pressure sensor material
Port size
Sensor
1850115
-1 ... 0
10
0,19
0,25
0,80
1.4404
G1/2
B
1850215
-1 ... 1
10
0,20
0,30
1,00
1.4404
G1/2
B
1850415
-1 ... 2,5
10
0,20
0,28
2,50
1.4404
G1/2
B
1851115
0,05 ... 1
10
0,16
0,18
0,80
1.4404
G1/2
B
1851215
0 ... 1,6
10
0,10
0,16
1,00
1.4404
G1/2
B
1851315
0,1 ... 2,5
10
0,18
0,22
2,00
1.4404
G1/2
B
1851415
0,5 ... 4
20
0,50
0,60
2,50
1.4404
G1/2
B
1851515
0,5 ... 6
20
0,60
0,70
5,00
1.4404
G1/2
B
1851615
0,5 ... 10
20
0,70
0,90
8,00
1.4404
G1/2
B
1851715
1 ... 16
50
1,60
1,90
12,00
1.4404
G1/2
F
1851815
1 ... 25
50
1,60
2,20
20,00
1.4404
G1/2
F
1851915
5 ... 63
150
2,00
5,00
20,00
1.4404
G1/2
H
*1) Atmospheric air pressure. *2) Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure.
Accessories Brackets
Surge damper
Pressure port reducing nipple
0574772 (Steel)
0553258 (G1/4, Stainless steel 14505, AISI 303/304 S)
0553831 (G1/2 & 1/2 NPT, Stainless steel 14505, AISI 303/304 S)
0553908 (Stainless steel)
0574773 (G1/4, Brass/Steel)
0550083 (G1/4A ... G1/2A, Stainless steel 14505, AISI 303/304 S) 0574765 (G1/4 ... 1/4 NPT, Brass)
20D Hydraulic ATEX
Microswitch with gold plated contacts
Technical features
• 5 … 400 bar, G1/4
For Ex zones 1 and 2 (gases) category II2G type of protection Ex db eb IIC T6 For Ex zones 21 and 22 (dusts) category II2D type of protection Ex tb IIIC T80°C IP65
P R E S S U R E S WI T C H E S & S E N S OR S
• Electro-mechanical pressure switch
Degree of protection: IP65 (DIN 40050) Fluid/Ambient temperature: -10°C … +75°C (+14°F … 167°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Materials: Housing: Aluminium diecast, anodised Sensor: Stainless steel (1.4404) Sealing: Steel piston (NBR or FPM)
Medium: For neutral, self lubricating fluids, hydraulic oil, lube oil, light fuel oil Operation: Piston
Switching pressure range *1) (bar)
Max. Over pressure *2) (bar)
Switching pressure difference (typical) Lower range Upper range (bar) (bar)
Fluid contact parts
Sensor
Port size
1846505
5 ... 160
300
5,00
9,00
Brass, steel, NBR
Piston
G1/4
1846705
10 ... 400
550
7,00
18,00
Brass, steel, FPM
Piston
G1/4
Adjustable switching pressure difference Symbol
Model
Switching pressure range *1) (bar)
Max. Over pressure *2) (bar)
Switching pressure difference (typical)
1856505
5 ... 160
300
8,00
22,00
1856705
10 ... 400
550
15,00
40,00
Fluid contact parts
Sensor
Port size
120,00
Brass, steel, FPM
Piston
G1/4
300,00
Brass, steel, FPM
Piston
G1/4
Lower Upper range range minimal maximal (bar) (bar) (bar)
*1) Atmospheric air pressure. *2) Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure.
Accessories Brackets
Surge damper
Pressure port reducing nipple
0574772 (Steel)
0553258 (G1/4, Stainless steel 14505, AISI 303/304 S)
0553831 (G1/2 & 1/2 NPT, Stainless steel 14505, AISI 303/304 S)
0553908 (Stainless steel)
0574773 (G1/4, Brass/Steel)
0550083 (G1/4A ... G1/2A, Stainless steel 14505, AISI 303/304 S) 0574765 (G1/4 ... 1/4 NPT, Brass)
For further information www.imi-precision.com
Model
93
Fixed switching pressure difference Symbol
3
3
33D Hydraulic / Allfluid Electronic lock
P R E S S U R E S WI T C H E S & S E N S OR S
• Electronic pressure switch
Technical features
• 0 … 630 bar G1/4 or Flange
Medium: For neutral and aggressive, gaseous and liquid fluids Fluid/Ambient temperature: -10°C … +80°C/-10°C … +60°C (+14°F … +176°F/+14°F … +140°F)
94
Output signal 1 x PNP
Materials: Sensor (fluid-affected parts): Stainless steel 1.4571 (0 … 250 bar) (0 … 3625 psi), Stainless steel 1.4542 (400 … 630 bar) (5800 … 9137 psi)
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Temperature sensitivity: Zero point < ± 0,4% of final value pro 10° Kelvin - typ. Range < ± 0,2% of final value pro 10° Kelvin - typ. Display: LCD 4 digits, illuminated, pressure unit programmable bar, psi, mpa (customer specific pressure unit available on request)
Symbol
For further information www.imi-precision.com
P
Easy programming of switchpoints and extra functions
Switching status indicated by LCD
Electrical parameters Power supply: UB = 10 to 32 V DC 15 to 32 V DC (analogue) polarity safe Output signal: Digital: UB minus 1.5 V Analogue: 4 to 20 mA Contact rating: Imax = 500 mA (short-circuit proof)
Model
Switching pressure range (bar)
Over pressure* (bar)
Fluid connection
Output signal
Display step size (bar)
0863112 **
0 ... 10
40
G1/4
1 x PNP
0,050
0863116
0 ... 10
40
Flange
1 x PNP
0,050
0863312 **
0 ... 40
100
G1/4
1 x PNP
0,200
0863316
0 ... 40
100
Flange
1 x PNP
0,200
0863412 **
0 ... 100
200
G1/4
1 x PNP
0,500
0863416
0 ... 100
200
Flange
1 x PNP
0,500
0863512
0 ... 160
300
G1/4
1 x PNP
0,500
0863516
0 ... 160
300
Flange
1 x PNP
0,500
0863612 **
0 ... 250
500
G1/4
1 x PNP
1,000
0863616
0 ... 250
500
Flange
1 x PNP
1,000
0863712 **
0 ... 400
750
G1/4
1 x PNP
2,000
0863812
0 ... 630
1000
G1/4
1 x PNP
2,000
* Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure. ** Standard models.
Output signal 2 x PNP Symbol
P
Model
Switching pressure range (bar)
Over pressure* (bar)
Fluid connection
Output signal
Display step size (bar)
0863122 **
0 ... 10
40
G1/4
2 x PNP
0,050
0863126
0 ... 10
40
Flange
2 x PNP
0,050
0863322
0 ... 40
100
G1/4
2 x PNP
0,200
0863422 **
0 ... 100
200
G1/4
2 x PNP
0,500
0863426
0 ... 100
200
Flange
2 x PNP
0,500
0863522
0 ... 160
300
G1/4
2 x PNP
0,500
0863526
0 ... 160
300
Flange
2 x PNP
0,500
0863622 **
0 ... 250
500
G1/4
2 x PNP
1,000
0863722 **
0 ... 400
750
G1/4
2 x PNP
2,000
0863822
0 ... 630
1000
G1/4
2 x PNP
2,000
* Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure. ** Standard models.
33D Hydraulic / Allfluid
3
Symbol
P
Model
Switching pressure range (bar)
Over pressure* (bar)
Fluid connection
Output signal
Display step size (bar)
0863142 **
0 ... 10
40
G1/4
1 x PNP / 4 ... 20 mA
0,050
0863342
0 ... 40
100
G1/4
1 x PNP / 4 ... 20 mA
0,200
0863442 **
0 ... 100
200
G1/4
1 x PNP / 4 ... 20 mA
0,500
0863542
0 ... 160
300
G1/4
1 x PNP / 4 ... 20 mA
0,500
0863642 **
0 ... 250
500
G1/4
1 x PNP / 4 ... 20 mA
1,000
0863742
0 ... 400
750
G1/4
1 x PNP / 4 ... 20 mA
2,000
0863842
0 ... 630
1000
G1/4
1 x PNP / 4 ... 20 mA
2,000
* Short-term pressure peaks are not allowed to exceed this limit value during operation. Operative utilization of the limit value is not permitted. The limit value corresponds to the maximum testing pressure.
** S tandard models.
Accessories Surge damper
Connector M 12 x 1 90°
0574767 (brass)
0574773 (brass)
0523058 (2 m cable, 4-core)
0550083 (Stainless steel)
0553258 (Stainless steel)
0523053 (5 m cable, 4-core)
Connector M 12 x 1 straight
0523056 (90° without cable)
0523057 (2 m cable, 4-core) 0523052 (5 m cable, 4-core)
0523055 (without cable)
95
Pressure port reducing nipple
P R E S S U R E S WI T C H E S & S E N S OR S
Output signal 1 x PNP/1 x analogue 4 ... 20 mA
0250081 (5 m cable length, 5-core, on PE-requirement*)
For further information www.imi-precision.com
* Cable with screening.
3
18S Allfluid Robust stainless steel housing
P R E S S U R E S WI T C H E S & S E N S OR S
• Electronic pressure sensor
Technical features
• 0 ... 800 bar G1/4
Medium: For neutral and aggressive gases or fluids Temperature: Fluid: -20°C ... +85°C or -40°C ... +125°C* (-4°F ... +185°F or 40°F ... +257°F)* Ambient: -20°C ... +85°C or -40°C ... +110°C* (-4°F ... +185°F or (-40°F ... +230°F)* * on request Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Degree of protection: IP65 (DIN 40050) with mounted plug
Supply voltage: 12 ... 30 V d.c. (current output) 15 ... 30 V d.c. (voltage output) Output signal: 4 to 20 mA (2-wire technology) 0 to 10 V (3-wire technology) Frequency output on request Electrical connection: M12 x 1/cable on request Temperature sensitivity: Zero point < ± 0,4% of final value pro 10° Kelvin - typ. Range < ± 0,2% of final value pro 10° Kelvin - typ. Materials: Housing: Stainless steel 1.4571/1.4542 Sensor: Stainless steel membrane 1.4542
Temperature compensated
96
18S Allfluid with M12 x 1 - Electrical connection Symbol
For further information www.imi-precision.com
P I
P U
Model
Measuring range (relative pressure) bar
Over pressure
Fluid connection
Output signal
0862170
0 ... 10
40
G1/4
4 ... 20 mA
0862370
0 ... 25
50
G1/4
4 ... 20 mA
0862470
0 ... 100
200
G1/4
4 ... 20 mA
0862670
0 ... 250
500
G1/4
4 ... 20 mA
0862770
0 ... 400
750
G1/4
4 ... 20 mA
0862970
0 ... 800
1000
G1/4
4 ... 20 mA
0862180
0 ... 10
40
G1/4
0 ... 10 Volt
0862380
0 ... 25
50
G1/4
0 ... 10 Volt
0862480
0 ... 100
200
G1/4
0 ... 10 Volt
0862680
0 ... 250
500
G1/4
0 ... 10 Volt
0862780
0 ... 400
750
G1/4
0 ... 10 Volt
0862980
0 ... 800
1000
G1/4
0 ... 10 Volt
0523057 (2 m cable, 4-core)
0523055 (without cable)
Plug not included. Alternative sensor ranges available on request.
Accessories Connector M 12 x 1 90°
0523058 (2 m cable, 4-core) 0523053 (5 m cable, 4-core) 0799845 ( 2 m cable length, 5-core, on PE-requirement*) 0250081 (5 m cable length, 5-core, on PE-requirement*) * Cable with screening.
Connector M 12 x 1 straight
0523056 (90° without cable)
0523052 (5 m cable, 4-core)
High overpressure
4 Air Preparation High efficiency water removal
Miniature high corrosion resistant design
Suitable for marine and offshore applications
4
Fast Find Guide
A I R P R E P A R A T I ON
Stainless steel - Air preparation F22
R22
Filter 1/2”
L22
Regulator 1/2”
0 … 17 bar SS
Page 99
R38
0,4 … 10 bar SS
Page 99
B38
Instrument Regulator 1/4”
0,04 … 10 bar SS
Lubricator 1/2”
0,25 … 10 bar SS
Page 99
0,5 … 15 bar SS
0 … 17 bar SS
0,3 … 9 bar SS
Page 100
B05
Filter Regulator 1/4” & 1/2”
Page 102
B38
1/2”
IFR3, IFR4
Instrument Filter Regulator 1/4”
Page 102
0 … 17 bar SS
Three Stage Filtration
0,3 … 8,6 bar SS
Page 104
W11, W12, W13
Filter - mesh element 3/8” … 1 1/2”
98
Page 105
Zinc or aluminium alloy - General purpose Air preparation For further information www.imi-precision.com
B72G, B74G
B68G
Excelon Filter Regulator 1/4" & 1/2
0,3 … 10 bar ALU, ZI
ALU
Aluminium
Olympian Filter Regulator 1”
Page 106
SS
0,4 … 8 bar ALU
Stainless Steel
Page 107
ZI
Zinc Die-casting
Page 101
Regulator 1/4”
Stainless steel - High pressure filtration
0 … 550 bar SS
Filter Regulator 1/4”,3/8”,1/2” & 1”
R05
Filter Regulator 1/4”
Page 103
B38P
Filter Regulator 1/2"
0,3 … 8,6 bar SS
Page 104
0,5 … 10 bar SS
Page 101
F22, R22, L22
Materials meet NACE
recommendations Technical features
• Filters, pressure regulators, lubricators
Medium: Compressed air only Maximum inlet pressure: 17 bar (246 psi) (F22, L22) 20 bar (290 psi) (R22) Filter element: 25 μm (F22) Gauge ports: 1/4 PTF (R22) Pressure range: R22: 0,4...10 bar (5,8 … 150 psi)
• 1/2” PTF
A I R P R E P A R A T I ON
• Stainless steel general purpose
4
Materials: Body & bowl: stainless steel (F22, L22) Filter element: PE- or sintered stainless steel (F22) Adjusting screw: stainless steel (R22) Elastomers: Synthetic rubber
Note: Outlet pressure can be adjusted in excess of and also less than those listed
Start point: (L22): 1,7 dm3/s at 6,3 bar Ambient/Media temperature: -20°C … +80°C (-4°F … +176°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Models
Accessories
Service Kit
F22 SERIES Port size
Flow* (dm3/s)
Wall mounting bracket
Auto drain
Manual drain
F22-400-A7DA
F22-400-M7DA
1/2 PTF
57
18-001-962
F22-KITA25
F22-KITM25
* Typical flow with 10 bar inlet pressure and 0,5 bar droop from a set pressure of 6,3 bar.
Models
Accessories
Service Kit
R22 SERIES Model
Port size
Flow* (dm3/s)
Wall mounting bracket
Neck mounting bracket
Gauge**
Service kit
R22-401-RNMA
1/2 PTF
50
18-001-962
18-001-959
18-013-909
R22-KITR
* Typical flow with 10 bar inlet pressure and 1 bar droop from a set pressure of 6,3 bar. ** Stainless Steel Items not strictly to NACE MR-01-75.
Models
Accessories
Service Kit
L22 SERIES Model
Port size
Flow* (dm3/s)
Wall mounting bracket
Service kit
L22-400-OP8A
1/2 PTF
48
18-001-962
L22-KIT
* Typical flow with 10 bar inlet pressure and 0,5 bar droop from a set pressure of 6,3 bar.
For further information www.imi-precision.com
MANUAL DRAIN Model
99
AUTO DRAIN Model
4
Three Stage Filtration 316 Stainless steel
A I R P R E P A R A T I ON
• Stainless Steel Three Stage Filtration
Technical features
• Particle and oil removal (coalescing) filters
Medium: Compressed air, Hydrocarbon gas* Air quality: Within ISO 8573-1, Class 1 (particulates) and Class 2 (oil content) Operating pressure: 17 bar (246 psi) max Filter elements: 1st stage: 25 µm 2nd stage: 5 µm 3rd stage: 0.01 µm Maximum remaining oil content in outlet air: 0,01 ppm at 20°C with an inlet concentration of 12 ppm. Ambient/Media temperature: -20°C … +80°C (-4°F … +176°F)
• 24-011-001 … 003, 1/2" PTF
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Materials: Body & bowl: 316 stainless steel Filter element: 316 sintered stainless steel, Acetal, synthetic fiber, EPDM, polyester Bowl sight glass: Pyrex Elastomers: NBR Manual drain: 316 Stainless steel, NBR Automatic drain: 316 Stainless steel, Nylon, Acetal, NBR Service life indicator Lens: Transparent nylon Internal parts: Acetal Spring: 18-8 Stainless steel
High efficiency
* Confirm compatibility with materials of construction. Use in gas applications must be in a well vented or outdoor area. Products are designed with an allowable leakage and should only be used within the specifications printed on the data sheet or the product label for pressure, temperature, etc. It is the responsibility of the user to apply the product in a safe environment free from potential fire or explosive materials or components. IMI Precision Engineering will not be responsible for any injury or damage caused by the use of the product in an unsafe application.
100
Technical data, standard model Symbol
For further information www.imi-precision.com
Model
Port size
Flow *1) (dm3/s)
Drain
Service life indicator
Weight (kg)
24-022-003
1/2 PTF
35,4
Manual
Visual
6,05
24-022-004
1/2 PTF
35,4
Automatic
Visual
6,29
*1) Maximum flow with at 6,3 bar inlet pressure to maintain stated oil removal performance.
Metallic parts meet NACE
B38, B38P Technical features
• Filter/regulator
Medium: Compressed air only Maximum inlet pressure: 17 bar (246 psi) (autodrain) 31 bar (449 psi) (manual drain) Flow: 100 dm3/s
• 1/4”,3/8”,1/2” & 1”
Materials: Body, bowl, bonnet, and adjusting screw: Stainless steel Filter element: PE (B38), Stainless steel (B38P) Elastomers: NBR (B38), FPM (B38P)
Typical flow with 12 bar inlet pressure, 8 bar set pressure and 1 bar droop from set
Gauge ports: 1/4” PTF Relief port: 1/8” PTF Ambient/Media temperature: -40°C … +80°C (-40°F … +176°F)
4 Metallic parts meet NACE
A I R P R E P A R A T I ON
• Stainless steel general purpose
Designed for use in corrosive enviroments
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Particle removal: 5 μm, 25 μm, 40 μm filter element
Models
Accessories
B38 SERIES - GENERAL PURPOSE Port size
Outlet Pressure range
Flow* (dm3/s)
Drain
Element
Neck mounting bracket & nut
Gauge**
B38-444-M1LA
1/2 PTF
0,3 … 9 bar
75
Manual
5 µm
18-001-973
18-013-909
B38-444-M2LA
1/2 PTF
0,3 … 9 bar
75
Manual
25 µm
18-001-973
18-013-909
B38-444-A1LA
1/2 PTF
0,3 … 9 bar
75
Automatic
5 µm
18-001-973
18-013-909
B38-444-A2LA
1/2 PTF
0,3 … 9 bar
75
Automatic
25 µm
18-001-973
18-013-909
101
Model
Models
Accessories
B38P SERIES - HIGH FLOW Model
Port size
Outlet Pressure range
Flow* (dm3/s)
Drain
Element
Neck mounting bracket & nut
Gauge**
B38P-254-B1MA
1/4 PTF
0,5 … 10 bar
40
Manual
5 µm
18-001-973
18-013-909
B38P-354-B1MA
3/8 PTF
0,5 … 10 bar
40
Manual
5 µm
18-001-973
18-013-909
B38P-454-B1MA
1/2 PTF
0,5 … 10 bar
75
Manual
5 µm
18-001-973
18-013-909
B38P-854-B1MA
1 PTF
0,5 … 10 bar
75
Manual
5 µm
18-001-973
18-013-909
B38P-254-A1MA
1/4 PTF
0,5 … 10 bar
40
Automatic
5 µm
18-001-973
18-013-909
B38P-354-A1MA
3/8 PTF
0,5 … 10 bar
40
Automatic
5 µm
18-001-973
18-013-909
B38P-454-A1MA
1/2 PTF
0,5 … 10 bar
75
Automatic
5 µm
18-001-973
18-013-909
B38P-854-A1MA
1 PTF
0,5 … 10 bar
75
Automatic
5 µm
18-001-973
18-013-909
* Typical flow with 12 bar inlet pressure and 1 bar droop from set pressure of 8 bar. ** Stainless Steel Items not strictly to NACE MR-01-75.
For further information www.imi-precision.com
* Typical flow with 12 bar inlet pressure and 1 bar droop from set pressure of 8 bar. ** Stainless Steel Items not strictly to NACE MR-01-75. Units supplied complete with panel mounting ring.
4
R38, B38
A I R P R E P A R A T I ON
• Stainless steel instrument
Technical features
• Regulators and Filter/regulators
Medium: Compressed air only Maximum inlet pressure: 17 bar (246 psi) (B38 automatic drain) 31 bar (449 psi) (R38 & B38 manual drain) Gauge ports: 1/4” PTF Pressure range: See table Note: Outlet pressure can be adjusted in excess of and also less than those listed Ambient/Media temperature: -40°C … +80°C (-40°F … +176°F)
• 1/4" PTF
Materials: Body, bowl, bonnet and adjusting screw: Stainless steel Filter element: PE (B38 only) Elastomers: Synthetic rubber
Suitable for marine and offshore applications
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Models
Accessories
R38 SERIES PRECISION PRESSURE REGULATOR Port size
Pressure range
Flow* (dm3/s)
Neck mounting bracket & nut
Gauge**
R38-240-RNCA
1/4 PTF
0,04 … 2 bar
8
18-001-973
18-013-913
R38-240-RNFA
1/4 PTF
0,07 … 4 bar
8
18-001-973
18-013-913
R38-240-RNMA
1/4 PTF
0,50 … 10 bar
8
18-001-973
18-013-909
102
Model
For further information www.imi-precision.com
* Typical flow with 7 bar inlet pressure and 0,05 bar droop from set pressure of 1 bar. ** Stainless Steel Items not strictly to NACE MR-01-75.
Models
Accessories
B38 SERIES PRECISION FILTER/REGULATOR Model
Port size
Pressure range
Flow* (dm3/s)
Drain
Filterelement
Neck mounting bracket & nut
Gauge**
B38-244-B1KA
1/4 PTF
0,25 … 7 bar
8
Manual
5 µm
18-001-973
18-013-909
B38-244-B2KA
1/4 PTF
0,25 … 7 bar
8
Manual
25 µm
18-001-973
18-013-909
B38-244-A1KA
1/4 PTF
0,25 … 7 bar
8
Automatic
5 µm
18-001-973
18-013-909
B38-244-A2KA
1/4 PTF
0,25 … 7 bar
8
Automatic
25 µm
18-001-973
18-013-909
B38-244-B1MA
1/4 PTF
0,4 … 10 bar
8
Manual
5 µm
18-001-973
18-013-909
B38-244-B2MA
1/4 PTF
0,4 … 10 bar
8
Manual
25 µm
18-001-973
18-013-909
B38-244-A1MA
1/4 PTF
0,4 … 10 bar
8
Automatic
5 µm
18-001-973
18-013-909
B38-244-A2MA
1/4 PTF
0,4 … 10 bar
8
Automatic
25 µm
18-001-973
18-013-909
* Typical flow with 7 bar inlet pressure and 0,05 bar droop from set pressure of 1 bar. ** Stainless Steel Items not strictly to NACE MR-01-75.
ATEX classification
IFR3, IFR4 Technical features
• Filter/regulator
Medium: Compressed air Maximum inlet pressure: 20 bar (290 psi) Outlet pressure range: Standard: 0,5 … 10 bar (7 … 145 psi) Ambient/Media temperature: Standard: -30°C … +90°C (-22°F … +194°F) Optional: -55°C … +90°C (-67°F … +194°F)
• 1/4" & 1/2" NPT
Materials: Valve body: 316 stainless steel Seat and spring: stainless steel O-rings, seals and diaphragm: NBR
ATEX
4 A I R P R E P A R A T I ON
• Stainless Steel General Purpose
Suitable for marine and offshore applications
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Models - No Gauge Symbol
Model
Port size
Outlet pressure *1) (bar)
Element (μm)
Flow *2) (dm3/s)
Drain
Gauge
YR2ACA1H0BS040
1/4 NPT
0,5 … 10
40
65
Manual
None
YR2ACA3H0BS040
1/2 NPT
0,5 … 10
40
160
Manual
None
103
*1) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. *2) Typical flow with 10 bar inlet pressure, 6,3 bar set pressure and a 1 bar drop from set.
Model
Port size
Flow *2) (dm3/s)
Drain Type
Element Size
Gauge Type
YR2ACA1H1BS005
1/4 NPT
65
Manual
5 µm
Dry
YR2ACA1H1BS040
1/4 NPT
65
Manual
40 µm
Dry
YR2ACA1H2BS005
1/4 NPT
65
Manual
5 µm
Glycerine filled
YR2ACA1H2BS040
1/4 NPT
65
Manual
40 µm
Glycerine filled
YR2ACA3H1BS005
1/2 NPT
160
Manual
5 µm
Dry
YR2ACA3H1BS040
1/2 NPT
160
Manual
40 µm
Dry
YR2ACA3H2BS005
1/2 NPT
160
Manual
5 µm
Glycerine filled
YR2ACA3H2BS040
1/2 NPT
160
Manual
40 µm
Glycerine filled
YR2AAA1H1BS005
1/4 NPT
65
Automatic
5 µm
Dry
YR2AAA1H1BS040
1/4 NPT
65
Automatic
40 µm
Dry
YR2AAA1H2BS005
1/4 NPT
65
Automatic
5 µm
Glycerine filled
YR2AAA1H2BS040
1/4 NPT
65
Automatic
40 µm
Glycerine filled
YR2AAA3H1BS005
1/2 NPT
160
Automatic
5 µm
Dry
YR2AAA3H1BS040
1/2 NPT
160
Automatic
40 µm
Dry
YR2AAA3H2BS005
1/2 NPT
160
Automatic
5 µm
Glycerine filled
YR2AAA3H2BS040
1/2 NPT
160
Automatic
40 µm
Glycerine filled
*2) Typical flow with 10 bar inlet pressure, 6,3 bar set pressure and a 1 bar drop from set.
For further information www.imi-precision.com
Models - inc. gauge
4
B05, R05
A I R P R E P A R A T I ON
• General purpose stainless steel
Technical features
• Regulators and filter-regulator
Medium: Compressed air only Maximum inlet pressure: 17 bar (246 psi) Filter element: 5 μm Gauge ports: 1/8” PTF Pressure range: 0,3 … 8,6 bar (4,4 … 123 psi) Ambient/Media temperature: -34°C … +66°C (-29°F … +176°F)
• 1/4” PTF
Metallic parts meet NACE Materials: Body and valve: Stainless steel 316 Bowl : Stainless steel 316 (B05 only) Bonnet: Stainless steel 316 Valve seat: Acetal Spring: Stainless steel 302 Drain: Stainless steel 316 (B05 only) Filter element: Sintered PE (B05 only) Elastomers: FPM Automatic drain: NBR (B05 only)
Miniature high corrosion resistant design
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
104
Models
Accessories
B05 SERIES
For further information www.imi-precision.com
Model
Port size
Flow* (dm3/s)
Gauge**
Mounting nut (Acetal)
B05-238-M1LA
1/4 PTF
5
18-013-844
2962-89
Model
Port size
Flow* (dm3/s)
Gauge**
Mounting nut (Acetal)
R05-232-RNLA
1/4 PTF
3
18-013-844
2962-89
Manual Drain.
R05 SERIES
* Typical flow with 10 bar inlet pressure and 1 bar droop from set pressure of 6,3 bar. ** Stainless Steel Items not strictly to NACE MR-01-75.
Suitable for marine, petro-chemical and similar applications
W11, W12, W13 Technical features
• Filter
Medium: Liquids and gases Maximum inlet pressure: W11: 550 bar (7977 psi ) W12: 420 bar (6091 psi) W13: 310 bar (4496 psi) Filtration: 25 µm standard Ambient/Media temperature: -10°C … +100°C (+14 … +212°F) standard -40°C … +150°C (-40 … +302°F) on request
• G3/8" … G1 1/2"
Materials Body: stainless steel bs en 10088 1.4401 Filter: stainless steel mesh O-Rings: NBR
Easy and quick maintenance of mesh element
Easy installation
4 A I R P R E P A R A T I ON
• High Pressure In-line filtration
Robust design
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Symbol
105
Technical data, standard models Model
Port size
Normal size (mm)
Weight (kg)
W11A9E2N25
G 3/8
10
1,0
G1
16
3,6
G 1 1/2
24
6,4
For further information www.imi-precision.com
W12A9E6N25 W13A9E8N25
4
B72G, B74G
A I R P R E P A R A T I ON
• Excelon modular system
Technical features
• Filter/regulators
Medium: Compressed air only Maximum inlet pressure: 10 bar (246 psi) Pressure range: 0,3 … 10 bar (5 … 150 psi) Filter element: 40 μm Gauge ports: Rc1/8 (B72 & B74 with ISO G thread) 1/8 PTF (B72 with PTF thread) 1/4 PTF (B74 with PTF thread) Ambient/Media temperature: -34°C … +65°C (-29°F … +149°F) (B72) -34°C … +80°C (-29°F … +176°F) (B74)
• G1/4" & G1/2", 1/4" & 1/2" PTF
Material: Body: Zinc die-casting (B72) Bonnet: Acetal (B72) Body & bonnet: Aluminium die-casting (B74) Valve: Brass/PE Metal bowl: zinc die-casting (B72) Metal bowl: Aluminium die-casting (B74) Liquid level indicator lens (Metal bowl): Transparent PA (Pyrex optional) Element: Sintered polypropylene Elastomers: CR and NBR
in-line installation or modular installation
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
106
Models
Accessories
B72G SERIES
For further information www.imi-precision.com
AUTO DRAIN Model
MANUAL DRAIN Model
Port size
Flow* (dm3/s)
Wall mounting bracket
Neck mounting bracket
Gauge 0 … 10 bar
Tamper resistant kit
B72G-2GK-AE3-RMN
B72G-2GK-QD3-RMN
G1/4
38
4224-50
74316-50
18-013-989
4255-51
B72G-2AK-AE3-RMN
B72G-2AK-QD3-RMN
1/4 PTF
38
4224-50
74316-50
18-013-212
4255-51
Models
Accessories
B74G SERIES AUTO DRAIN Model
MANUAL DRAIN Model
Port size
Flow* (dm3/s)
Wall mounting bracket
Neck mounting bracket
Gauge 0 … 10 bar
Tamper resistant kit
B74G-4GK-AD3-RMN
B74G-4GK-QD3-RMN
G1/2
100
4324-50
4368-51
18-013-013
4355-51
B74G-4AK-AD3-RMN
B74G-4AK-QD3-RMN
1/2 PTF
100
4324-50
4368-51
18-013-209
4355-51
High efficiency water removal
B68G High efficiency water removal Technical features
• Filter/regulators
Medium: Compressed air only Maximum inlet pressure: 17 bar (246 psi) Filterelement: 40 μm Gauge ports: ISO G ports have Rc1/8 gauge port PTF ports have 1/8 PTF gauge ports Ambient/Media temperature: -20°C … +80°C (-4°F … +176°F)
• G1" & 1" PTF
A I R P R E P A R A T I ON
• Olympian Plus plug-in system
4
Materials: Body, bonnet, bowl & yoke: Aluminium die-casting Adjusting knob: Acetal resin Elastomers: Synthetic rubber Filter element: Sintered plastic
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Pressure range: 0,4...8 bar (6...120 psi) Note: Outlet pressure can be adjusted in excess of and also less than those listed
Accessories
107
Models B68G SERIES Manual drain Model
Port size
Flow* (dm3/s)
Wall mounting bracket
Gauge 0 … 10 bar
Tamper resistant kit
B68G-8GK-AR3-RLN
B68G-8GK-MR3-RLN
G1
240
18-001-979
18-013-013
4355-51
B68G-8AK-AR3-RLN
B68G-8AK-MR3-RLN
1" PTF
240
18-001-979
18-013-204
4355-51
* Typical flow with 10 bar inlet pressure and 1 bar droop from set pressure of 6,3 bar. For replacement filter/regulator (without yoke) substitute “N” at the 5th and 6th digits eg. B68G-NNK-AR3-RLN.
For further information www.imi-precision.com
Auto drain Model
4
A I R P R E P A R A T I ON
108
5 Ancillary Products
For outdoor use
Stainless steel
Reduced noise levels
5
Fast Find Guide
A N C I L L A R Y P R OD U C T S
Quick exhaust valves QEV
1/4” … 1”
0,5 … 12 bar SS
Page 111
Exhaust filters 0613422, 0613423 1/4” & 1/2”
0 … 10 bar POM
Page 112
Silencers MB Series
0014, 0613 Series
110
1/8" … 1"
-1 … 20 bar AL
T40
1/4", 1/2"
Page 113
0 … 25 bar SS
M/S
M5 … 1”
Page 114
M5 … 1”
0 … 10 bar BR
Page 115
-1 … 10 bar PE
Page 116
For further information www.imi-precision.com AL
Aluminium
BR
Brass
SS
Stainless Steel
PE
Polyethylene
POM
Plastic Polymer
QEV • Quick exhaust valves
Technical features
• 1/4 … 1 NPT
Medium: Compressed air and other neutral gases Operating pressure: 0,5 … 12 bar (7 … 174 psi) Leak Performance: Bubble tight Fluid/Ambient temperature: -50°C … +80˚C (-58 ... +176°F)
Materials: Valve body & trim: 316L stainless steel O-Rings seats & seals: NBR
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Symbol
2 3
*1) Measured in USgpm for 1 psi ∆p.
Model
Port size
Flow factor Cv *1)
Kv *2)
QEV13AA1H00S
1/4 NPT
1,6/2,1
23,2/30,5
QEV13AA3H00S
1/2 NPT
6,4/5,5
92,8/79,8
QEV13AA5H00S
3/4 NPT
10,4/10,8
149
QEV13AA6H00S
1 NPT
10,4/15,4
149
*2) Measured in l/min for 1 bar (15 psi) ∆p.
For further information www.imi-precision.com
1
111
Technical data, standard models
5 A N C I L L A R Y P R OD U C T S
Stainless steel
5
0613422, 0613423
A N C I L L A R Y P R OD U C T S
• Exhaust guard
Technical features
• 1/4” & 1/2”
Medium: Lubricated or non-lubricated compressed air, inert gases Operation: The non-return function protects the spring chamber of pneumatic actuators in particular against aggressive ambient air Operating pressure: 10 bar max. (145 psi) Operating temperature: -55°C … +80°C (-67 … +176°F)
Materials: Housing: POM ‘O’-rings: VMQ
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
112
Models Symbol
Model
Thread
Suitable for
0613422
1/4”
G1/4, 1/4 NPT
0613423
1/2”
G1/2, 1/2 NPT
universal thread BSP/NPT
Protects against contamination and moisture penetration
For further information www.imi-precision.com
MB Series Technical features
• R1/8"...R1", 1/8"PTF...1"PTF
Medium: Compressed air, filtered, lubricated and non-lubricated, inert gases Operating pressure: -1 … 20 bar (-14 ... 290 psi) Ambient temperature: -20°C … +80°C (-4 … +176°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Symbol
Corrosion resistant
113
Models
Materials: Aluminium body and shell, brass mesh element
A N C I L L A R Y P R OD U C T S
Reduce the noise levels
• Quietaire heavy duty silencers
5
Male Thread Port Size
MB001B
R1/8
MB002B
R1/4
MB003B
R3/8
MB004B
R1/2
MB006B
R3/4
MB008B
R1
Male Thread Model PTF
Port Size
MB001A
1/8 PTF
MB002A
1/4 PTF
MB003A
3/8 PTF
MB004A
1/2 PTF
MB006A
3/4 PTF
MB008A
1 PTF
For further information www.imi-precision.com
Model BSPT
5
0014, 0613 Series
A N C I L L A R Y P R OD U C T S
• Stainless steel silencers
Technical features
• G1/4 & G1/2, 1/4 NPT & 1/2 NPT
Medium: Compressed air, filtered and non-lubricated Operating pressure: 25 bar max. (362 psi) Fluid/Ambient temperature: -25°C … +100°C (-13 … +212°F)
Prevent the ingress of dirt Materials: Filter element: stainless steel Body: stainless steel
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
114
Technical data Symbol
For further information www.imi-precision.com
Model
Port size
Flow kv l/min
Continuous sound pressure level *1) 0,7 bar 6 bar
0014613
G1/4
12
63
78
0613678
1/4 NPT
12
63
78
0014813
G1/2
45
58
76
0613679
1/2 NPT
45
58
76
*1) Measured in dBA/1 meter in front and side from unit.
T40 Technical features
• M5, G1/8 … G1
Medium: Compressed air, filtered, lubricated or non lubricated, inert gases Operating pressure: 10 bar (145 psi) maximum Operating temperature: -40°C … +80°C (-40 … +176°F)
Shock and vibration resistant
Materials: Element: sintered bronze Body: brass
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
Symbol
Model with ISO G-threads BSPP
Model with ISO R-threads BSPT
Port size
Flow factor Cv
Kv *1)
Continuous sound pressure level *2) 0,7 bar 6 bar
T40M0500
–
M5
0,2
0,21
56
70
T40C1800
T40B1800
G1/8
0,54
0,53
66
75
T40C2800
T40B2800
G1/4
1,6
1,34
68
78
T40C3800
T40B3800
G3/8
3,5
2,98
75
84
T40C4800
T40B4800
G1/2
5,1
4,47
75
88
T40C6800
T40B6800
G3/4
9
7,88
87
96
T40C8800
T40B8800
G1
11,6
10,22
93
100
For further information www.imi-precision.com
*1) Measured in m3/h. *2) SPL in dBA at 1 m from unit.
115
Technical data, Standard models
5 A N C I L L A R Y P R OD U C T S
• Sintered bronze silencers
Reduce the noise levels
5
M/S
A N C I L L A R Y P R OD U C T S
• Porous plastic silencers
Technical features
• M5, G1/8 … G1
Medium: Compressed air, filtered 50 µm, lubricated and non lubricated/vacuum, inert gases Operating pressure: -1 … +10 bar maximum (-14 … 145 psi) (vacuum service) Fluid/Ambient temperature: -20°C … +80°C (-4 … +176°F)
Reduce the noise levels
Materials: Body: UHMW polyethylene porous plastic Connector base: polyethylene
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)
116
Technical data, standard models Symbol
Model
Port size
Mean flow factor C *1 Cv
Kv *2
Sound pressure level *3)
For further information www.imi-precision.com
M/S0
M5
1,27
0,31
0,27
83
M/S1
G1/8
4,1
1
0,87
84
M/S2
G1/4
7,5
1,84
1,6
84
M/S3
G3/8
16,2
4
3,45
81
M/S4
G1/2
21,8
5,3
4,64
82
M/S6
G3/4
32,8
8
7
98
M/S8
G1
49,8
12,2
10,6
94
*1) Measured in dm3/ (s.bar). *2) Measured in m3/h. *3) Measured in dBA/6bar/1 meter from unit.
Prevent the ingress of dirt
6 Additional Products
6
ACTUATORS
A DDI T I ON A L P R OD U C T S
Integrated Valve and Actuator Control (IVAC)
Impact (â&#x20AC;&#x2DC;Rappingâ&#x20AC;&#x2122;) Cylinder
> Complete actuator and valve package in one unit
> Used in waste incineration plants for efficient cleaning
> Simplified specification and design, ordering, installation and maintenance
> Adjustable impact level reduces wear, lowering maintenance costs
> 1 Air and 1 electrical connection
> Range of accessories includind mountings and force compensators
> Cleanline corrosion resistant body
> Full control package available in standard or customised designs
> Number of solenoid options including ATEX certification
Glandless spool valve Cleanline Design
118
For further information www.imi-precision.com
ATEX Zone 2
Cleaning of heating surfaces
Horizontal boiler with installed impact system
Approved
CONTROL SYSTEMS
A DDI T I ON A L P R OD U C T S
Control Panel Solutions
6
Custom designed solutions for all kinds of applications - simple to complex. > Complete solutions, ready to install > Designed using 2D+3D CAD software > Can be pneumatic, electro-pneumatic, and also include ancillary products > Assembled and texted prior to delivery
119
Customized solutiions
For further information www.imi-precision.com
6
A DDI T I ON A L P R OD U C T S
120
Index
Index SERIES
PAGES
122
For further information www.imi-precision.com
SERIES
PAGES
VALVES
15
R22 Pressure regulator
99
97100 Inline
24
L22 Lubricator
99
97105 Inline
25
Three Stage Filtration
100
97105 NAMUR
26
B38, B38P Filter / Regulator
101
97300 NAMUR
29
R38, B38 Regulators and Filter / Regulators
102
26360 & 80207 Inline
30
IFR3, IFR4 Filter / Regulator
103
26360 & 80207 NAMUR
31
B05, R05 Filter Regulator & Regulator
104
98025 NAMUR & Inline
33
W11, W12, W13 Filter
105
6215M NAMUR & Inline
35
B72G, B74G Filter/Regulator
106
6215L NAMUR & Inline
37
B68G Filter/regulator
107
24011 NAMUR & Inline
39
ANCILLARY PRODUCTS
109
24010 NAMUR & Inline
43
QEV Quick exhaust valves
111
98015 NAMUR & Inline
44
0613422, 0613423 Exhaust guard
112
21000 Inline
46
MB Quietaire heavy duty silencers
113
23200 Inline
47
0014, 0613 Stainless steel silencers
114
24000 Inline
48
T40 Sintered bronze silencers
115
95000 Inline
50
M/S Porous plastic silencers
116
96000 Inline
51
6316 Inline
56
YX1 ICO3S EX ia Inline
57
YO1 ICO3S Inline
58
Y1 ICO4S Inline
59
82400 and 82730
64
82470
66
82540 & 82590
67
82960, 82970 diaphragm
68
82900, 82910 diaphragm
69
85500, 85540 piston
70
85780 piston
71
84500 & 84520
72
V81, V82, V83 & V84 RVM system
73
80400 pneumatically actuated
77
I/P & E/P CONVERTERS
79
140 Failsafe
81
422 Fail Freeze
82
422 IS Fail Freeze
83
VP10
84
100X
85
220
86
PRESSURE SWITCHES & SENSORS
87
18D ATEX
89
18D Hydraulic ATEX
91
20D Allfluid ATEX
92
20D Hydraulic ATEX
93
33D Hydraulic / Allfluid
94
18S Allfluid
96
AIR PREPARATION
97
F22 Filter
99
Solenoid index PAGES
4231
54
0242
32
4260
41
0245
32
4261
41
0246
52
4270
40, 44
0700
54
4271
40, 44
0763
27, 33
4280
55
0800
40, 44, 55
4281
55
0827
41
4600
27, 33, 38
1300
49
4601
27, 33, 38
1301
49
4602
27, 38
1440
49
4603
27, 38
1441
49
4610
32, 36, 52
1500
49
4611
32, 36, 52
1501
49
4612
32, 36, 52
1570
49
4613
32, 36, 52
1571
49
4620
53
1600
49
4621
53
1601
49
4622
53
2003
43
4623
53
2050
28
4630
54
2051
28
4631
54
2052
28
4632
54
2053
28
4633
54
3034
24
4660
41
3036
29
4661
41
3039
24
4662
41
3050
24, 29
4663
41
3062
24, 29
4670
40, 44
3063
24, 29
4671
40, 44
3204
53
4672
40, 44
3206
52
4673
40, 44
3703
54
4680
55
3720
38
4681
55
3722
36
4682
55
3723
36
4683
55
3803
40, 44, 55
4802
27
3805
41
4803
27
3824
41
4872
40, 44
3825
41
4873
40, 44
3826
40
6316****.6001
56
3827
40
4200
27, 33, 38
4201
27, 33, 38
4210
32, 36, 52
4211
32, 36, 52
4220
53
4221
53
4230
54
For further information www.imi-precision.com
SERIES
53
SERIES
123
PAGES
0200
Notes
124
For further information www.imi-precision.com
For further information, scan this QR code or visit www.imi-precision.com
1 2 3 4 5 6
VALVES IMI HERION VALVES - INTERCHANGEABLE COILS IMI MAXSEAL VALVES - INTEGRATED SOLENOIDS IMI BUSCHJOST DIAPHRAGM VALVES IMI BUSCHJOST PISTON VALVES IMI BUSCHJOST ANGLE SEAT PILOT VALVES REDUNDANT VALVE MANIFOLD SYSTEM IMI HERION BOOSTERS
I/P & E/P CONVERTERS 140 SERIES 422 SERIES 422 IS SERIES VP10 RANGE 100X SERIES 220 SERIES
PRESSURE SWITCHES & SENSORS 18D ATEX & 18D HYDRAULIC RANGE 18D REMAINING HYDRAULIC RANGE PLUS ACCESSORIES 20D ALLFLUID & HYDRAULCI RANGE PLUS ACCESSORIES 33D HYD/ALLFLUID RANGE PLUS ACCESSORIES 18S ALLFLUID RANGE PLUS ACCESSORIES
AIR AND GAS PREPARATION F22, R22 & L22 RANGES PLUS ACCESSORIES 22 SERIES 3 STAGE FILTRATION B38, B38P & B38 AND R38 INSTRUMENT RANGES PLUS ACCESSORIES IFR3, 4 FILTER REGULATOR RANGES B05 FILTER/REG, R05 REG AND W11 FILTER B72, B74, B64 & B68 RANGES PLUS ACCESSORIES
ANCILLARY PRODUCTS QEV RANGE 0613422/3 EXHAUST GUARD & MB QUIETAIRE SERIES SILENCERS 0014, 0613, T40 & M/S RANGE SILENCERS
ADDITIONAL PRODUCTS INTEGRATED VALVE AND ACTUATOR CONTROL (IVAC) IMPACT (‘RAPPING’) CYLINDER REDUNDANT VALVE MANIFOLD (RVM) SYSTEM CONTROL PANEL SOLUTIONS
Norgren, Buschjost, FAS, Herion and Maxseal are registered trademarks of IMI Precision Engineering companies. Due to our policy of continuous development, IMI Precision Engineering reserve the right to change specifications without prior notice. z8409CT en/10/17 Selected Images used under license from Shutterstock.com