® VRV

Catalogue ■

DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH campus 21, Europaring F12/402, A – 2345 Brunn/Gebirge Tel.: +43 / 22 36 / 3 25 57-0, Fax: +43 / 22 36 / 3 25 57-900 e-mail: office@daikin.at, www.daikin-ce.com

The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V./Daikin Central Europe HandelsGmbH. Daikin Europe N.V./Daikin Central Europe HandelsGmbH has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V./Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

Daikin products are distributed by:

ECPEN12_02_dace_VRV • Copyright Daikin We reserve the right for printing errors and model changes.

V R V ® C ATA LO G U E 2 012

Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.

ALL SEASONS PERFECT C MFORT

2012


BENEFITS FOR

building OWNERS With Daikin’s proprietary inverter technology and cutting-edge control technology for refrigerant, the VRV®III air conditioning system operates with outstanding efficiency. This contributes to high energy savings, which GREATLY REDUCES facilitates better building management.

YOUR RUNNING COSTS

and

CONSULTANT and DESIGN OFFICES Benefits for

Daikin’s VRV® systems include indoor and outdoor units available in a wide range of models for various building sizes and installation conditions. Long refrigerant piping lengths and other features put few restrictions on design for GREAT building.

Benefits for

FLEXIBILITY in meeting needs of the

INSTALLERS Daikin offers a compact design for VRV® outdoor units by further optimising equipment functions, exceeding the norm for air conditioning systems. Compact units

FACILITATE

INSTALLATION in limited areas, such as rooftops, and take up less effective space. Easier installation work realises FAST COMPLETION with time to spare.

Benefits for

END USERS To provide a COMFORTABLE AIR ENVIRONMENT , Daikin offers air treatment systems beyond mere air conditioning. As well as bringing air to a comfortable temperature, the air quality can be improved with ventilation, humidification, and other processes.

EASE OF USE is realised through advanced, centralised control systems.


TABLE OF CONTENTS The next generation VRV ... About Daikin What’s new Daikin VRV® history The Total Solution concept Which VRV® system is the best for you?

4 6 8 10 12 14

Unit overviews Outdoor units Indoor units Ventilation units Biddle air curtains Hydroboxes Control solutions Selection programs

16 18 20 21 21 21 22

LARGE COMMERCIAL APPLICATIONS VRV OUTDOOR SYSTEMS Introduction & Benefits Benefits for building owners Benefits for design offices and consultants Benefits for installers Benefits for end users Advanced VRV technologies

NEW

24 25 28 30 33 35

Heat recovery systems REYAQ-P REYQ-P8/P9 / REYHQ-P9

38 42

Heat pump systems RXYQ-P9 / RXYHQ-P9 RTSYQ-P RXYRQ-P RXYSQ-P8

46 50 54 56

Replacement VRV RQCEQ-P / RQYQ-P

58

Water-cooled VRV RWEYQ-P / RWEYQ-PR

62

Branch selector boxes (BS-boxes) BSVQ-P8 BSV4Q-PV / BSV6Q-PV

67 67

2


VRV INDOOR UNITS Ceiling mounted cassettes Auto cleaning decoration panel FXFQ-P9 FXZQ-M9 FXCQ-M8 FXKQ-MA Ceiling suspended units FXUQ-MA FXHQ-MA

NEW

Wall mounted units FXAQ-P

68 NEW

70 71 72 73 74

NEW

75 76

77

Concealed ceiling units (Duct units) FXDQ-M9 FXDQ-P7 FXSQ-P / FXMQ-P7 FXMQ-MA

78 79 80 82

Floor standing units FXNQ-P FXLQ-P

83 84

Hot water units HXHD-A Hot water unit accessories

85 86

VENTILATION Heat reclaim ventilation VAM-FA VKM-G(M)

89 90

Outdoor air processing unit FXMQ-MF

91

VRV air handling applications EKEQMCB Plug&Play VRV connection AHU

92 93

Heat pump inverter condensing units ERQ 102

NEW

Biddle air curtains CYQ-DK- CYV-DK-

104 105

CONTROLS, OPTIONS & ACCESSORIES NEW

CONTROL SYSTEMS Individual control systems BRC1E- Overview of other individual controls

107 108

Centralized control systems Overview of basic central controls 109 DCS601C51 Intelligent Touch Controller 110 DAM602B51/52 Intelligent Manager 111

NEW NEW

Advanced individual unit control & interfaces RTD- Universal control adaptors DTA113B51 DS-Net adaptor KKRP01A Online Controller

NEW

Standard protocol interfaces KLIC-DI / -DD KNX protocol RTD-NET Modbus protocol DMS502A51 BACnet protocol DMS504B51 LonTalk protocol

NEW

OPTIONS & ACCESSORIES Notable accessories K.RSS Wireless temperature sensor 118 KRCS01-1 / -4 Wired temperature sensor 118 Other integration devices 119

NEW

Options & Accessories overview pages VRV outdoor units VRV indoor units Ventilation units Refrigerant distribution

112 113 114

3

116 116 117 117

120 122 124 124


The next generation VRV …

PR

EL I

M

IN AR Y

Available 2nd half 2012

VRV IV Heat Pump & Heat Recovery* ›› Personalize your VRV to achieve highest possible seasonal efficiency and comfort with advanced evaporating & condensing temperature control ›› Perfect heating comfort: continuous heating during defrost (also on Heat Pump) ›› USB commissioning

New round flow cassette* ›› The optional presence sensor adjusts set point or switches off the unit when nobody is in the room saving up to 27% of energy ›› The optional presence sensor directs air flow away from people to avoid draught ›› Save up to 50% of energy thanks to daily filter cleaning with optional auto cleaning panel (Wolverhampton, UK test site) ›› The flexibility to adapt the air flow pattern to a changed interior *preliminary

4


VRV Heat Pump - RYCQ-A* AR Y

›› For smaller projects, with standard cooling & heating requirements

IN

›› Connectable to all VRV indoor units, controls and ventilation

IM

›› Total piping length: 300m

EL

›› Maximum piping length: 165m

PR

›› Range: 8 - 20HP

* ›› Contemporary design

›› Modbus

›› User friendly interface

›› Manage up to 2,560 groups of indoor units

›› Increased flexibility

›› Energy management tools help to prevent energy waste

›› USB connection

›› Remote refrigerant containment check on VRV

›› Better acceptance of DX technology to condition fresh air ›› Easier integration of ERQ in a total HVAC solution via new Intelligent Touch Manager *preliminary

5

PR

›› Perfect comfort thanks to continuous heating during defrost

EL IM

IN

AR Y

New ERQ*


Daikin Europe N.V.

ABOUT DAIKIN Daikin has a worldwide reputation based on 85 years’ experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use.

Daikin quality Daikin’s much envied quality quite simply stems from the close attention paid to design, production and testing as well as aftersales support. To this end, every component is carefully selected and rigorously tested to verify its contribution to product quality and reliability.

TOTAL CLIMATE CONTROL: Setting new standards Total climate control in which perfect living and working conditions are delivered inside a building is now both achievable and economically viable using the Daikin VRV® system. At the heart of the VRV® climate control system is our renowned, cutting-edge heat pump technology that delivers very high levels of energy efficiency by using renewable energy from the outdoor air to drive the heating and cooling process. Without the need for a secondary heating system, this technology delivers high output for low input, leading to a direct saving in CO2 emissions and running costs. But the Daikin VRV® goes further and uses the same advanced technology to extract heat from areas needing cooling and then reuses it to warm other areas or create hot water, thus enabling it to heat and cool different parts of the building at the same time. This combination of technologies means that our system regularly delivers a Coefficient of Performance (COP) of 4 or more, meaning that it produces four units of heat energy for every one unit of electrical energy used. And, when operating in heat recovery mode, the COP can be has high as 10, making the Daikin VRV® system the most advanced of its kind. 6


BE YOND THE ORDINARY To achieve perfect indoor conditions means delivering the optimal comfort levels from the perspective of the occupants by ensuring the right temperature in the right places, with the right level of fresh air and humidity, and all with an acceptable level of sound. It also means delivering attention to detail in all aspects of the technical configuration. Daikin’s approach is a total engineered solution that focuses not only on the core components but also on the equipment that can be connected to our new generation of VRVŽ systems. Our latest equipment is designed to optimise the performance of the total system by automating as much of the routine controls and checks as possible and by providing a global network of local engineers to help maintain top efficiency.

Energy efficiency, more then COP Some of the areas on which we focus include indoor units that have an automatic filter cleaning function to maintain optimum airflow and reduce energy consumption, while our concealed ceiling units have inverter driven fans that automatically adjust the airflow. Similarly, our automatic charging and containment check ensures the right levels of refrigerant, again ensuring the highest possible efficiency. And then there is the matter of control system. Here we have created a user-friendly integrated control unit that regulates just about everything and even takes the weather into account to ensure that the inside conditions are optimised no matter what the outside conditions. Indeed, the Daikin total climate control solution is beyond the ordinary.

This sign highlights features where Daikin has invested into technologies to reduce the impact of air conditioning on the environment.

7


what's new? TOTAL SOLUTION VRV

p. 38

›› A VRV system covering all of your cooling and heating needs ›› Produce hot water virtually for free thanks to heat recovery in cooling Total COP’s approaching 9 in simultaneous cooling-heating operation 80°C hot water with pure heat pump technology - without any direct electrical heating All hydraulic equipment included for simple Plug&Play installation

45°C - 75°C

OR EKHWP 45°C - 75°C

EKHTS

25°C - 45°C

25°C - 75°C

REYAQ-P

HXHD125A

High sensible option on VRV®III heat pump

p. 33, 46

›› Optimise the working of the units for the European climate. ›› Work with increased sensible capacity in cooling mode, resulting in higher efficiency and improved comfort. Higher comfort to the end user Preventing cold draughts thanks to higher discharge air temperature on the indoor unit. Higher energy efficiency As no energy is wasted on unnecessary dehumidification, the system will work more efficiently while in cooling mode.

›› The best seasonal performance and the lowest running cost in the industry ›› All standard VRV®III features 8


VRV®III heat pump, with connection to stylish indoor units

p. 54

›› Innovative VRV® technology combined with stylish and silent indoor units ›› Wide range of indoor units: combine VRV® indoor units and stylish indoor units such as Daikin Emura and Nexura in one system ›› Up to 39 indoor units can be connected to a single 18HP unit

p. 56

VRV®III-S heat pump ›› ›› ›› ››

Slim design for flexible installation Wide range of indoor units: either connect VRV® or stylish indoor units such as Daikin Emura, Nexura … Up to 9 indoor units can be connected All indoor units can be individually controlled

FTXG-J

FVXS-F

BPMKS967B3

FBQ-C FTXS-G BPMKS967B2

FCQ-C8

FTXG-J FVXG-K BPMKS967B2

1.5 kW indoor units

p. 72, 77, 79

›› Units especially developed for small or well-insulated rooms, such as hotel bedrooms or small offices. ›› Available as 4-way blow cassette (FXZQ) and concealed ceiling unit (FXDQ-P7) . Wall mounted (FXAQ-P) unit will become available in the second half of 2012.

9


over 25 years of VRV ® History In anticipation of

The introduction

phase out dates

of the VRV®II-S series extends

for all CFC based

VRV® operating scope into

equipment, Daikin

the light commercial

Europe steps up the

sectors. Available in 4, 5 and

production of VRV

6HP capacities, the system is

air conditioning

designed for installation in up

units using R-407C.

to 9 rooms.

®

The original VRV® air conditioning system developed by Daikin

Daikin Europe celebrates its

Industries Ltd. in 1982 is introduced into Europe in VRV® standard format. VRV® D series can supply conditioned air from up to 6 indoor units connected to a single outdoor unit.

25th anniversary with the award of an ISO14001 environmental certificate and the introduction of VRV® Inverter series with R-407C, in cooling only or heat pump format. As many as 16 indoor units can be connected to 1 single outdoor unit.

1987

1991

1994

1998

2003

2004

A further step forward

Daikin introduces the VRV®II, the

is taken in 1991 with the

world’s first R-410A operated variable

introduction of the

refrigerant flow system. Available in

VRV® heat recovery system,

cooling only, heat pump and heat

offering simultaneous cooling

recovery versions, the system, which

and heating from different

represents a considerable advance

indoor units on the same

over earlier VRV® systems, demonstrates

refrigeration circuit.

Consistent high quality and efficiency lead to the widespread acceptance of the VRV® concept and Daikin becomes the first Japanese air conditioning manufacturer to be awarded the ISO9001 certification. Daikin applies yet another quantum leap to VRV® technology: the VRV® Inverter-H series, operate up to 16 indoor units from just 1 outdoor unit.

10

Daikin’s innovative application of new technology. No less than 40 indoor units in heat recovery as well as heat pump format can be connected to a single refrigerant circuit.


Daikin has extended the

Daikin has extended its VRV® range with the innovative replacement

operational scope of its acclaimed

VRV® – a highly cost effective replacement for VRV® systems still

VRV®II inverter driven dx air

operating on the banned R-22 refrigerant. This cost effective upgrade is

conditioning system, with a new

possible because VRV®III-Q outdoor units can be installed using existing

water cooled version,

piping and in some cases existing indoor units. The system, among

VRV -WII. Available in 10, 20 and

the first of its type, comes in heat pump and heat recovery models

30HP models, the system operates

with capacities between 5 and 30HP and offers drastically increased

on R-410A refrigerant and is

efficiencies and considerable reductions in energy consumption

available in both heat pump and

compared to R-22 systems.

®

heat recovery versions.

2005

2006-2007

2008

2009

2010

Daikin has announced the third

Daikin introduces a new heat

generation of its much acclaimed

pump range optimised for

VRV range with the extensively

heating (VRV®III-C). This new range

re engineered VRV®III. Available

has an extended operation

in heat recovery, heat pump

range down

and cooling versions, VRV®III

to -25°C and has a greatly

incorporates all the best features

improved COP in low ambient

Daikin has extended the VRV®III

of earlier VRV® systems. However,

temperatures, with the newly

range with the re-engineered

it also possesses a considerable

developed 2-stage compressor

water cooled VRV®-WIII, which is

number of new design, installation

system.

available in 9 different outdoor

®

and maintenance refinements as

combinations from 8 to 30HP.

automatic charging

A geothermal version is also

and testing.

available now.

Up to 64 indoor untis

This system uses geothermal heat

can be connected to

as a renewable energy source

one system.

and can operate down to -10°C in heating mode.

11


Total Solution Concept The Daikin VRV® Total Solution provides a single point of contact for the design and maintenance of your integrated climate control system. Our modular units enable you to select the right mix of equipment and technology to ensure that you achieve the optimal balance of temperature, humidity and air freshness for the perfect comfort zone with maximum energy efficiency and cost effectiveness.

VRV® OUTDOOR UNITS Integrated heat pump solution ›› ›› ››

Solution for every climate from -25°C to +50°C Flexible to fit any building Top efficiencies to ensure low running costs and CO2 emissions

HEATING AND COOLING

USER FRIENDLY CONTROL SYSTEMS

22

Wide range of indoor units that fit rooms of any size and shape

Full control for maximum efficiency

›› ›› ›› ››

›› From individual control to the management of multiple buildings ›› User friendly touch screen control ›› Remote control & monitoring via internet

Perfect comfort Whisper-quiet operation Stylish design Concealed installation possible

+

Save up to 15% compared to traditional systems

12


Cooling 22

Extracted heat 22

Heating

VRV® heat recovery system

Hot Water

Ventilation

Air Curtain

AIR SEPARATION THROUGH AIR CURTAINS

VENTILATION

HOT WATER

A highly efficient solution to doorway climate separation

Create a high-quality indoor environment

Use heat pump technology to produce hot water

›› Most efficient open-door solution ›› Year-round comfort, even on the most demanding days ›› Free air curtain heating possible

›› Heat is reclaimed between out and indoor air ›› Free cooling possible ›› Optimum control of humidity ›› For one room or your entire building

›› Free hot water production possible ›› Possibility to connect to solar panels ›› Possible applications: bathrooms, sinks, under floor heating and radiators ›› Hot water up to 80°C

+

Save up to 72% compared to an electric air curtain

+

Save up to 40% thanks to lower cooling and heating requirements

13

+

Save up to 17% compared to a gas boiler


Which VRV ® outdoor system offers me the best solution? Air cooled outdoor systems  Heat Recovery

›› For simultaneous heating and cooling from one system ›› Heat exhausted from indoor units in the cooling cycle is merely transferred to units in areas requiring heat, maximising energy efficiency, reducing electricity costs and leading to high partload efficiencies (up to 91). ›› Operation range in cooling down to -20°C (technical cooling)

Standard series optimised solutions Small footprint combination ›› Optimized footprint within heat recovery range

1

Heat Pump

REYQ8P8 50% cooling – 50% heating load. Conditions: outdoor temperature 11°CDB, indoor temperature 18°CWB, 22°CDB.

›› For either heating or cooling operation from one system

Standard series optimised solutions Small footprint combination ›› Optimized footprint within heat pump range

High COP combination ›› Top energy efficiency in Daikin heat pump range

VRV® Heat Pump with connection to stylish indoor units ›› Innovative VRV® technology combined with stylish and silent indoor units

VRV ® Heat Pump optimised for heating ›› First system in the industry developed for heating operation at low ambient conditions. ›› Extended operation range for heating down to -25°C ›› Stable heating capacity and high efficiencies at low ambient temperatures (COP > 3 at -10°C outdoor temperature)

VRV ®III-S Heat Pump ›› Especially designed for small capacities ›› Space saving design ›› Either connect VRV® or stylish indoor units: Daikin Emura, Nexura…

Replacement

VRV® heat recovery, with connection to heating only hydrobox ›› Fully integrated system ›› Free hot water High COP combination ›› Top energy efficiency in Daikin heat recovery range

›› For cost-effective upgrade from R-22/R-407C to R-410A ›› Increased energy efficiency compared to R-22/R-407C systems ›› Fast installation compared to total system replacement (re-use of existing piping and in some cases indoor units) ›› Available in heat recovery and heat pump 14


Water cooled outdoor systems ›› Allows heat recovery within the total building, thanks to the storage of energy in the water circuit. ›› Compact design and stacked configuration possible. ›› Suitable for multi-storey and large buildings because of the hardly unlimited possibilities of water piping.

Heat Recovery

Standard series Geothermal series ›› For simultaneous heating and cooling from one refrigerant system

Heat Pump

›› No need for an external heating or cooling source ›› Heating with ground sourced water as a renewable energy source ›› Extension of the operation range of inlet water temperature down to -10°C in heating mode

Standard series Geothermal series ›› For either heating or cooling operation from one refrigerant system

15

›› No need for an external heating or cooling source ›› Heating with ground sourced water as a renewable energy source ›› Extension of the operation range of inlet water temperature down to -10°C in heating mode


overview outdoor unit range System

4

5

6

8

10

12

14

16

18

20

22

1

Type

Product name

Cooling capacity (kW)

11.2

14.0

15.5

22.4

28.0

33.5

40.0

45.0

49.0

55.9

61.5

Heating capacity (kW)2

12.5

16.0

18.0

25.0

31.5

37.5

45.0

50.0

56.5

62.5

69.0

Cooling capacity (kW)3

22.4

26.7

44.8

49.1

53.4

Heating capacity (kW)4

25.0

31.5

50.0

56.5

63.0

10

12

REYAQ-P

NEW ››› HEAT RECOVERY

for connection with heating only hydrobox REYHQ-P High COP combination

REYQ-P8/P9 Small footprint combination

RXYHQ-P9 High COP combination

AIR COOLED

NEW ›››

RXYQ-P9 Small footprint combination

HEAT PUMP

NEW ›››

RTSYQ-P Heat pump optimised for heating

NEW ›››

RXYRQ-P Heat pump with connection to stylish indoor units

RXYSQ-P8Y1 (Three phase)

H/R - H/P

SERIES

STANDARD GEOTHERMAL

System

H/R - H/P

NEW ›››

SERIES

RXYSQ-P8V1 (Single phase)

WATER COOLED

NEW ›››

Type

RWEYQ-P

RWEYQ-PR

Product name

4

5

8

13

14

16

18

20

22

500

540

636

280

Cooling capacity (kW)1  HR/HP

-/14.0

-/22.4 28.0/28.0 -/33.5

36.0/-

-/40.0

50.0/50.4 54.0/55.9 63.6/61.

Heating capacity (kW)2  HR/HP

-/16.0

-/25.0

40.0/-

-/45.0

52.0/50.0 56.0/56.5 60.0/62.5 67.2/69.

1 2 3 4

-/37.5

RQCEQ-P HEAT PUMP

HEAT RECOVERY -

Q REPLACEMENT VRV®

AIR COOLED

NEW ›››

32.0/31.5

360

460

140

Capacity class

VRV®III-Q - H/R

Q RQYQ-P VRV®III-Q - H/P

Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, inlet water temperature : 30°C, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal cooling capacities are based on: indoor temperature : 27°CDB, 19°CWB, inlet water temperature : 30°C, equivalent refrigerant piping : 7.5m, level difference : 0m Nominal heating capacities are based on: indoor temperature : 20°CDB, inlet water temperature : 20°C, equivalent refrigerant piping : 7.5m, level difference : 0m

16


22

Capacity (HP) 42

44

46

48

50

52

54

116.0

120.0

126.0

132.0

138.0

143.0

147.0

75.0

81.5

88.0

94.0

102.0

107.0

113.0

119.0

126.0

132.0

138.0

145.0

151.0

158.0

163.0

170.0

67.2

71.5

75.8

80.1

75.0

81.5

88.0

94.5

Indoor Air Hydrobox Ventilation units curtain connection

+ x + + +

+

+

+ +

+

+ x + + +

+

x

+ +

+

+ x + + +

+

x

+ +

+

+ x + + +

+

x

+ +

+

+ x + + +

+

x

+ +

+

+ x + + +

+

x

+ +

+

+ + + x x

x

x

+ +

+

+ • + x +

+

x

+ +

+

+ • + x +

+

x

+ +

+

+ x + + +

+

x

+ +

+

+ x + + +

+

x

+ +

+

26

28

30

712

744

816

848

32

34

36

38

40

42

44

46

48

.5 71.2/67.0 74.4/73.0 81.6/78.5 84.4/85.0 -/90.0

-/96.0

-/101.0

-/107.0

-/112.0

-/118.0

-/124.0

-/130.0

-/135.0

.0 78.4/75.0 80.8/81.5 87.2/87.5 89.6/95.0 -/100.0

-/108.0

-/113.0

-/119.0

-/125.0

-/132.0

-/138.0

-/145.0

-/150.0

50

52

54

+ • x 5 6

17

VRV® type indoor units (such as FXSQ)

Capacity (HP) 24

Control systems

Network solutions (such as DCS6*/DAM/DMS 6)

40 111.0

Individual control (such as BRC 6)

38 105.0

Centralised control (such as DCS3*/DST 6)

36 98.0

Heating only HT hydrobox

34 94.0

Comfort air curtain (CAVS)

32 89.0

AHU connection kit (such as EKEXV)

30 82.5

Heat Reclaim ventilation (such as VAM)

28 77.0

Fresh air indoor units (such as FXMQ-MF)

26 71.4

Residential type indoor units (such as Daikin Emura) 5

24 67.0

BP-box required Exact control possibilities depend on the selected system components All + components can be connected together to 1 system Can be connected, but not in combination with other components Can not be connected


overview indoor unit range VRV® air conditioning brings summer freshness and winter warmth to offices, hotels, department stores and many other commercial premises. It enhances the indoor environment and creates a basis for increased business prosperity and whatever the air conditioning requirement, a Daikin indoor unit will provide the answer. VRV® air conditioning can be supplied via 26 different indoor unit models in a total of 116 variations. The Roundflow cassette now includes a self cleaning filter, which automatically cleans itself daily, leading to yearly energy savings of up to 10%. Dust from the filter is collected in the unit for removal by simple vacuum cleaning.

Capacity Type

Model

Product name

15

20

25

32

40

50

63

71

Cooling capacity (kW)1

1.7

2.2

2.8

3.6

4.5

5.6

7.1

Heating capacity (kW)2

1.9

2.5

3.2

4.0

5.0

6.3

8.0

CEILING MOUNTED CASSETTE

Round flow cassette

NEW ›››

autocleaning function possible

80

100

125

140

200

250

8.0

9.0

11.2

14.0

16.0

22.4

28.0

9.0

10.0

12.5

16.0

18.0

25.0

31.5

FXFQ-P9

4-way blow ceiling mounted cassette

FXZQ-M9

2-way blow ceiling mounted cassette

FXCQ-M8

Ceiling mounted corner cassette

FXKQ-MA

Small concealed ceiling unit FXDQ-M9

FLOOR STANDING

CEILING SUSPENDED

WALL MOUNTED

CONCEALED CEILING

NEW ›››

1 2 3 4

Slim concealed ceiling unit Concealed ceiling unit with inverter driven fan

FXDQ-P7

FXSQ-P

Concealed ceiling unit with inverter driven fan

FXMQ-P7

Large concealed ceiling unit

FXMQ-MA3

Wall mounted unit

FXAQ-P

Ceiling suspended unit

FXHQ-MA

4-way blow ceiling suspended unit

FXUQ-MA

Floor standing unit

FXLQ-P

Concealed floor standing unit

FXNQ-P

Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m Not connectable to VRV®III-S (RXYSQ-P8V1, RXYSQ-P8Y1) Decoration panel BYCQ140CG + BRC1E51A needed

18


Capacity

CONCEALED CEILING

CEILING MOUNTED CASSETTE

Type

Model Round flow cassette autocleaning function possible

WALL MOUNTED FLOOR STANDING

CEILING SUSPENDED

NEW ›››

20

25

35

42

50

60

71

FCQ-C8

4-way blow ceiling mounted cassette

FFQ-BV

Small concealed ceiling unit

FDBQ-B

Slim concealed ceiling unit

FDXS-E/C

Concealed ceiling unit with inverter driven fan

FBQ-C

Daikin Emura

NEW ›››

Product name

Wall mounted unit

FTXG-J CTXG-J

Wall mounted unit

FTXS-J

Wall mounted unit

FTXS-G

Ceiling suspended unit

FHQ-B

Nexura floor standing unit

FVXG-K

Floor standing unit

FVXS-F

Flexi type unit

FLXS-B

The indoor units in the table above are only connectable to RXYRQ-P, RXYSQ-P8V1 and RXYSQ-P8Y1, in case of RXYRQ-P these indoor units can be combined with standard VRV® indoor units in the same system 2 Decoration panel BYCQ140CG + BRC1E51A needed 1

19


overview ventilation range Ventilation: provision of fresh air

1

Air processing: optimse the balance between indoor and outdoor fresh air temperature

Type

Product name

Components of indoor air quality

VAM-FA

1

2

Humidification: optimise the balance between indoor and outdoor humidity

2 3

Air flow rate (m3/h) 0

200

400

600

1 Ventila­tion

3

HEAT RECLAIM VENTILATION

VKM-G

2

1

3 Air processing

3

VKM-GM

1

2 3

OUTDOOR AIR PROCESSING UNIT 1

FXMQ-MF

VRV® AIR HANDLING APPLICATIONS 2

EKEXV-kit

1 2 3

2 3

2 Humidification

1 Ventila­tion 3 Air processing

3

1

1 Ventila­tion 3 Air processing

2

1

1 Ventila­tion

1 Ventila­tion 3 Air processing

Not connectable to VRV®III-S (RXYSQ-P8V1, RXYSQ-P8Y1) Air flow rate is a calculated indication only, based on the following values: heating capacity EKEXV-kit * 200m³/h For more information on Daikin air handling units refer to your local dealer

20

800

1,000 1,500 2,000

4,000

6,000

8,000


overview biddle air curtain range Product Name

Type BIDDLE COMFORT AIR CURTAIN (CA) FREE HANGING

CYV S/M/L/XL-DK-F

BIDDLE COMFORT AIR CURTAIN (CA) CASSETTE

CYV S/M/L/XL-DK-C

BIDDLE COMFORT AIR CURTAIN (CA) RECESSED

CYV S/M/L/XL-DK-R

Door height (m) 4

3.8m 3.5m

3.3m

Biddle comfort air curtain range

3.0m

2.8m

3

3.0m 2.5m

2.5m

2.4m

2.2m

2.2m

2

1

S

M

L

XL

S

Favourable ex: covered shopping mall or revolving door entrance

M

L

XL

M

Normal ex: little direct wind, no opposite open doors, building with ground floor only

L

XL Installation condition

Unfavourable ex: location at a corner or square, multiple floors and / or open stairwell

Overview hydrobox range Type

Product name

125

HXHD-A

HEATING ONLY HYDROBOX 1

1

Capacity

Only connectable to REYAQ-P

overview network solutions

1 2

• •

• •

+++

N/A N/A

Gateway for Lonworks networks Gateway for BACnet networks

21

8

Max. Indoors groups

• •

++

User friendliness

• •

+

Scheduling presets (programs)

ACNSS connection air conditioning network service system

Free cooling changeover

Sliding t° avoids overcooling via sensor

Power limit control

Other control functions

0° Between cooling & heating

Pre cooling / heating

Eco mode

Http option

Web acces & control

Ppd

Options

Visualisation

• •

BACnet 2

Graphical report

• •

DMS-IF 1

Control via GSM

Daily/monthly/yearly reports

Touch screen

Intelligent Manager

Password security

Malfunction code

Indication filter replacement

Basic monitoring functions: ON/OFF status, operation mode, set point temp.

Intelligent touch controller

Monitoring

Fire emergency stop control

Automatic changeover

dS-net

Weekly schedule control

Basic control functions: ON/OFF, temp. Setting, air flow settings

Control

+

4x10

+++ 2x64

128 +++ 1024

N/A 64 N/A 4x64


Powerful Selection Programmes 1. VRV ® pro, design tool Features: The VRV® Pro selection programme is a true VRV® design tool. The programme enables VRV® air conditioning systems to be engineered in a precise and economical way, taking into account the realtime thermal properties of any building. By calculating annual energy consumptions, it gives the designer the possibility to make accurate selections and get competitive quotations for each project. Moreover, it ensures optimum operating cycles and maximum energy efficiency. 1. VRV® Pro Quick: With a limited number of building properties, this mode allows to design the piping system using the available load calculation that was obtained from another party. 2. VRV® Pro Expert: To be able to make an accurate load calculation, a more extensive number of building properties is needed. After this calculation, the appropriate units are selected and a temperature simulation can be done. Next to the detailed report, there is a lot of additional, valuable information in the programme about energy consumption, related electricity expenses and behaviour of the VRV® system.

22


2. Xpress, quick quotation tool Xpress is a software tool that allows creating on the spot quotations for a Daikin VRV速 or CMS System. It provides a result in 7 steps to enable a professional budget quotation: 1. 2. 3. 4. 5. 6. 7.

Select indoor units Connect outdoor units to indoor units Automatic generation of piping diagram with joints Automatic generation of wiring diagram Select possible centralised control systems Visualise result in MS Word, MS Excel and AutoCAD Save project

The Daikin Europe Academy offers specialised training courses to teach designers how to work with VRV速 Pro. After this training, all attendees receive a renewable licence for 1 year. For more information about these trainings and to get your free copy of Xpress, please contact the local Daikin representative.

23


vrv ® outdoor systems Air cooled VRV® air conditioning was introduced to Europe by Daikin in 1987 and since then has undergone considerable development in performance, capacity, energy efficiency and environmental acceptability. Internationally regarded as one of the most

SOPHISTICATED AND VERSATILE system of its type on the market, VRV

®

has in fact, become the

benchmark for technologically advanced, high efficiency commercial and industrial air conditioning.

Available in third generation, heat recovery, heat pump, cold climate and mini versions, the VRV ® system is

EXTREMELY FLEXIBLE with an operational capacity range of 5 (14.0kW) to 54HP (170.0kW) (heat pump small footprint combination) and 8 (22.4kW) to 48HP (151.0kW) (heat recovery small footprint combination) in capacity increments of just 2HP. VRV® system versatility is also underlined by its operating temperature ranges of -5° C to 46° C in cooling (VRV®III-S) and -25° C to 15° C in heating (VRV®III-C).

Despite the remarkable energy efficiency and installation flexibility of the air cooled VRV®, there are some applications for which the water cooled version provides a more economic and sustainable solution. These apply primarily to

MULTI STOREY HIGH RISE COMPLEXES in which maximum refrigerant pipe distances can sometimes invalidate the use of an air cooled system. Further situations which are ideal for water cooled VRV® use include buildings lacking adequate roof or external space for outdoor condensing units and projects with particularly stringent noise regulations.

The water cooled VRV® is now available in 9 models between 8 and 30 HP, in heat recovery, heat pump and most recently,

GEOTHERMAL variants. The fast growing geothermal sector in fact, provides an ideal opportunity for ground source heat pumps and offers considerably future potential for its use in very low carbon installations.

24


benefits for building owners

Top quality - Only brazed connections All flange and flare connections inside the unit have been replaced by brazing connections to ensure improved refrigerant containment. Also the connection of the outdoor in the main pipe is brazed.

Flare or flange

5HP/14kW OUTDOOR UNIT

Compressor Capacity Control

The linear VRV速 system makes use of a variable Proportional Integral (PI) control system which uses refrigerant pressure sensors to give added control over inverter and ON/OFF control compressors in order to abbreviate control steps into smaller units to provide precise control in both small and larger areas. This in turn enables individual control of up to 64 indoor units of different capacity and type at a connection ratio of 50~130 % in comparison with outdoor units capacity. 5HP outdoor units use inverter control compressors only. VRV速 systems have low running costs because it permits each zone to be controlled individually. That is, only those rooms that require air conditioning will be heated or cooled, while the system can be shut down completely in rooms where no air conditioning is required.

100%

18 Steps

1 24% Small

Load

100% Compressor Capacity Control

Energy saving and indiviual zone control - Inverter technology

Large

18HP/44.5kW OUTDOOR UNIT

1 1 3 1 2 2

55 Steps

9% Small

Load

Large

Brazing

Ahead of environmental legislation RoHS Compliance Restriction of Hazardous Substances in electrical and electronic equipment (2002/95/EC). Hazardous substances include Lead (Pb), Cadmium (Cd), Hexavalent Chromium (Cr6+), Mercury (Hg), Polybrominated biphenyls (PBB), Polybrominated diphenylether (PBDE). Although RoHS regulations are only applicable to small and large household equipment, Daikin environmental policy nevertheless ensures that VRV速 will be totally in line with RoHS. 25


A long lasting investment Anti Corosion Treatment

An anti-corrosion heat exchanger cutaway view Hydrophilic film Aluminium

Special anti corrosion treatment of the heat exchanger provides 5 to 6 times greater resistance against acid rain and salt corrosion. The provision of rust proof steel sheet on the underside of the unit gives additional protection.

Corrosion-resistant Acrylic resin

Heat exchanger

Improvement in corrosion resistance Corrosion resistance rating Non-treated

Anti-corrosion treated

1 1

5 to 6 5 to 6

Salt corrosion Acid rain

VDA Wechseltest Contents of 1 cycle (7 days): ›› 24 hours salt spray test SS DIN 50021 ›› 96 hours humidity cycle test KFW DIN 50017 ›› 48 hours room temperature & room humidity testing period: 5 cycles

Degree of corrosion

Performed tests: 8 7 6 4 Bare aluminium

2 1 0 1

2

3

4

DAIKIN P.E.

5 Cycle

10 9

Kesternich test (SO2) ›› contents of 1 cycle (48 hours) according to DIN50018 (0.21) ›› testing period : 40 cycles

Degree of corrosion

8 7 6 5 4 3 2 1 0

Duty Cycling

1

2

3

Multiple outdoor units systems

The cyclical start-up sequence of multiple outdoor units systems equalized compressor duty and extends operating life.

Low installation cost - Sequential Start Up to 3 outdoor units can be connected to 1 power supply and can be turned on sequentially. This allows the number of breakers and their capacities to remain small and simplifies wiring (for models of 10HP or less). 26

4

5

6

10

20

30

40 Cycle


A solution for R-22 phase out Due to significant developments in heat pump technology, older systems of air conditioning run less efficiently than those available today. Furthermore the use of virgin R-22 is banned in Europe. To upgrade R-22 systems as cost effective as possible, Daikin replacement VRV® units can be installed using existing pipe-work.

What is R-22 and why is it phased-out in Europe? Due to ozone layer depletion, harmful ultraviolet rays reach the surface of the earth giving rise to a number of health and environmental issues. The international community therefore, signed the Montreal Protocol to phase out ozone depletion materials by 2030. The European Union however, decided to ban R-22 already in 2015. Daikin advises to replace your existing installation already today.

R-22 is a hydrochlorofluorocarbon (HCFC) which was commonly used in air conditioning systems. When R-22 is released into the air, the ultraviolet rays of the sun cause it to decompose and chlorine is released in the stratosphere. Chlorine reacts with ozone, reducing the amount of the ozone.

When will R-22 be banned in europe?

2004

2005

Ban of the sale of R-22 air conditioning equipment

2006

Daikin advises to replace your existing R-22 installation

2009

2010

2011

Ban on the use of virgin R-22 for service & maintenance

2014

2015

Ban on the use of all R-22 for service & maintenance

Only reclaimed & recycled 1 R-22 allowed

1

Recycled: re-use of R-22 following a basic cleaning process. Recycled R-22 must be re-used by the same company that carried out the recovery (can be done by installer) Reclaimed: reprocessed R-22 in order to meet the equivalent performance of virgin R-22 (by specialized company)

27


benefits for design offices and consultants A solution for every climate - Wide operation range The VRV® system can be installed practically anywhere. Advanced PI(Proportional Integral) control of the outdoor unit enables VRV® series to operate at outdoor ambients up to 43°C (VRV®III-S up to 46°C) in cooling mode and down to -20°C (VRV®III-C down to -25°C) in heating mode. With the technical cooling function the operation range in cooling of the heat recovery system is extended from -5°C to -20°C 1.

HEAT RECOVERY • HIGH COP COMBINATION • SMALL FOOTPRINT COMBINATION

HEAT PUMP OPTIMISED FOR HEATING Cooling 43°CDB

Cooling 43°CDB

50° 40° Cooling & Heating 15.5°CWB

10° 0° -10° -20°

-5°CWB

-20°CWB

-20°CWB

Heating 15.5°CWB

-5°CDB

Technical Cooling

Heating 20° 15.5°CWB

Technical Cooling

30°

1

-20°CWB

Contact your local dealer for more information and restrictions

28

Cooling 46°CDB

Heating 15.5°CWB

-5°CDB

-5°CWB

-25°CDB

VRV®III-S HEAT PUMP

Cooling 43°CDB

Heating 15.5°CWB

-20°CDB

-30°

HEAT PUMP • HIGH COP COMBINATION • WITH CONNECTION TO Stylish INDOOR UNITS • SMALL FOOTPRINT COMBINATION

-5°CDB

-20°CWB


Multiple tenants, one outdoor unit - Multi tenant function This function ensures that the entire VRV® system does not shut down when the main power supply of an indoor is switched off. This means that the indoor unit’s main fuse can be turned off when leaving a hotel room, when a part of the office building is closed, … * This option is available on the following indoor units: FXFQ-P9, FXZQ-M9, FXDQ-M9, FXDQ-PB, FXDQ-NB, FXSQ-P, FXMQ-P7, FXAQ-PV, FXLQ-P Consult the accessories table of the indoor units on necessary options.

Typical hotel application

TV

TV

TV

Power off CARD CARD

CARD

HOLDER

220 V

No structural reinforcement necessary Thanks to the vibration-free and sufficient light (max. 585kg for a 18HP unit) construction of the outdoor units, floors do not need to be reinforced, reducing the overall cost of the building.

Indoor installation The VRV®III optimised fan blade shape increases output and reduces pressure loss. Together with the high ESP setting (ESP up to 78pa), this makes the VRV® outdoor unit ideal for indoor installation and the use with ducts.

29


BENEFITS FOR installers Easy installation - Refrigerant Containment Check1 The refrigerant volume of the complete system is calculated from the following data: ›› outdoor temperature ›› reference system temperatures ›› reference pressure temperatures ›› refrigerant density ›› types and number of indoor units When activating the refrigerant containment check, the unit switches into cooling mode and duplicates certain reference conditions based on memory data. The result indicates whether or not refrigerant leakage has occurred. 1

Not available on VRV® heat pump with connection to stylish indoor units and VRV®III-S

Easy replacement - Refrigerant Recovery Function The refrigerant recovery function enables all expansion valves to be opened. In this way the refrigerant can be drained from the piping system.

Short Installation Time Thanks to small refrigerant pipes and REFNET piping options, the VRV® piping system can be installed very easily and quickly. Installation of the VRV® system can also be implemented floor by floor, so that sections of the building can be put into use very quickly, or enabling the air conditioning system to be commissioned and operated in stages, rather than on final completion of the project. 30


Automatic Charge Function Daikin’s total engineered solution ensures that, right from installation, the system has the correct refrigerant charge no matter what the original plan called for. In this way, the optimal efficiency and capacity is maintained thus delivering the correct level of heating or cooling for optimal comfort.

Conventional Way: 1. calculation of additional refrigerant charging volume 2. charging the unit with additional refrigerant 3. measuring the weight of the cylinder 4. judgment based on pressure (test operation)

VRV® With VRV® however, these 4 steps are omitted since the VRV® unit can be charged automatically with the necessary amount of refrigerant via a push button on the PCB. Automatic charging will cease once the appropriate amount of refrigerant has been transferred. If the temperature drops below 20°C* manual charging is necessary. * 10°C for heat pump for cold regions * Function not available on VRV® heat pump with connection to stylish indoor units

Automatic Test When refrigerant charging has ceased, pushing the test operation button on the PCB will initiate a check on the wiring, shut off valves, sensors and refrigerant volume. This test ceases automatically when completed.

Refrigerant Piping Front

4-way piping connection VRV® series not only offer the possibility to run piping from the front, but also from the left, right or bottom, thus providing greater freedom of layout.

Left 4-Way piping connection

Right Bottom

DAIKIN Unified REFNET piping The unified Daikin REFNET piping system is especially designed for simple installation. REFNET joint

Attached insulators for REFNET joint

REFNET header

Attached insulators for REFNET header

The use of REFNET piping in combination with electronic expansion valves, results in a dramatic reduction in imbalance in refrigerant flowing between indoor units, despite the small diameter of the piping. REFNET joints and headers (both accessories) can cut down on installation work and increase system reliability. Compared to regular T-joints, where refrigerant distribution is far from optimal, the Daikin REFNET joints have specifically been designed to optimise refrigerant flow.

REFNET joint

T-joint

Daikin Europe N.V. advises only to use Daikin REFNET piping system. 31


Modular design Modular design enables units to be joined together in rows with an outstanding degree of uniformity. The design of the outdoor units is sufficiently compact to allow them to be taken up to the top of a building in a commercial elevator, overcoming site transportation problem, particularly when outdoor units need to be installed on each floor.

Easy wiring - “Super Wiring” System

Simplified wiring A Super Wiring system is used to enable the shared use of wiring between indoor units, outdoor units and the centralised remote control. This system makes it easy for the user to retrofit the existing system with a centralised remote control, simply by connecting it to the outdoor units. Thanks to a non polarity wiring system, incorrect connections become impossible and installation time is reduced. Furthermore, outdoor units have power connection outlets on side and front, resulting in easier installation and maintenance and saving space when rows of units are connected together.

Cross wiring check The cross wiring check facility available on the VRV® is the first of its type in the industry to warn operatives of connection errors in inter unit wiring and piping. This function identifies and alerts system errors by means of on/off LEDs on the outdoor unit’s PC boards.

Auto Address Setting Function Allows wiring between indoor and outdoor units, as well as group control wiring of multiple indoor units, to be performed without the bothersome task of manually setting each address.

Easy Maintenance

Self Diagnostic Function This function operated via push button on the PCB, speeds up troubleshooting and should be used for start-up and maintenance. Disconnected thermistors, faulty solenoid valves or motor operated valves, compressor malfunctions, communication errors, etc can be diagnosed quickly. 32


BENEFITS FOR end users Smart Control Brings Comfort

Cooling

NEW ›››

Suction air temp.

An electronic expansion valve, using PID (Proportional Integral Differencial) control, continuously adjusts the refrigerant volume in respond to load variations of the indoor units. The VRV® system thus maintains comfortable room temperatures at a virtually constant level, without the temperature variations typical of conventional ON/OFF control systems.

VRV® SERIES (DAIKIN indoor unit (PID controlled)) ON/OFF controlled indoor unit (2.5HP)

Time Note: The graph shows the data, measured in a test room assuming actual heating load. The thermostat can control stable room temperature at ± 0.5°C from set point.

High sensible mode – your system optimised for the European climate The high sensible mode option on the VRV® outdoor units optimises the working of the units for the European climate. The system works with an increased sensible capacity in cooling mode resulting in improved comfort and a higher efficiency.

Higher comfort to the end user Preventing cold draughts thanks to higher discharge air temperature on the indoor unit.

16°

Two possibilities: - Standard high sensible mode: high cooling comfort with priority to capacity - Locked evaporation temperature mode: full priority to cooling comfort ›› constant and high air discharge temperature ›› easier to select air discharge grilles

Constant and high air discharge temperature

Discharge t° Locked Te mode Standard high sensible mode Standard setting

16°C 11°C 7°C Extremely high cooling load

Higher energy efficiency As no energy is wasted on unnecessary dehumidification, the system will work more efficiently in cooling mode. * Option is activated through service mode on outdoor unit. Locked Te mode is available only on RXYQ-P9 units.

Comfort guaranteed at all time Back -up Function In the event of a compressor malfunction, the remotely controlled or field set back-up function in the outdoor unit in question will allow emergency operation of another compressor, or another outdoor unit module in case of a multi system, in order to maintain 8 hour maximum interim capacity. 33

Single outdoor unit with multiple compressors

Multi outdoor unit system


Low indoor unit operation sound level ›› Daikin indoor units have very low sound operation levels, down to 25dB(A).

Silent Mode

dB(A)

Perceived loudness

Sound

0 20 40 60 80 100 120

Treshold of hearing Extremely soft Very soft Moderately loud Very loud Extremely loud Threshold of feeling

Rustling leaves Quiet room Normal conversation City traffic noise Symphonic orchestra Jet taking off

Daikin indoor units

Outdoor Units Quietness is another important feature. To reduce noise and ensure comfortable operation, the latest technologies and features have been applied to the outdoor units.

VRV® air cooled units

VRV®III-S air cooled units

Night quiet function (max. -13dBA)

Night quiet function (max. -8dBA)

Peak in the outdoor temperature

%

8 hrs

Peak in the outdoor temperature

%

8 hrs

10 hrs

10 hrs

%

%

Night Mode dBA

dBA

Night Mode

dBA dBA

Step 1: max. - 8dB (10HP)

Step 1: 50dB

Step 2: max. - 13dB (10HP)

Step 2: 45dB

dBA dBA

Step 1 max. - 3dB (4HP/11.2Kw)

Step 1: 47dB

Step 2 max. - 6dB (4HP/11.2Kw)

Step 2: 44dB

Step 3 max. - 9dB (4HP/11.2Kw)

Step 3: 41dB

time of day

time of day Night mode starts

Night mode starts

Night mode ends

— Capacity* %

Notes:

— Load %

This function is available for on site setting.

Night mode ends

The relationship between outdoor temperature (load) and time shown in

— Operation Sound dBA

the graph is merely an example.

During the night the sound level of the outdoor unit can be reduced for a certain period: starting time and ending time can be put in 2 modes1 with low sound level at night: ›› Mode 1 Automatic mode Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours2 after the peak temperature in the daytime and operation will return to normal after 10 hours3. ›› Mode 2 Customized mode Starting and ending times can be put in. (External control adapter for outdoor unit, DTA104A61 or DTA104A62 and a separately ordered timer are necessary.) Notes:

1

2

3

Determine which mode to select depending on the climatic characteristics of each country. Initial setting. Can be selected from 6, 8 and 10 hours. Initial setting. Can be selected from 8, 9 and 10 hours.

Effect on capacity (cooling) when using silent mode Soundlevel Step 1

50dB

Step 2

45dB

Capacity (kW) Capacity (kW)

5HP 14.7 100% 11.9 93%

8HP 19.9 98% 15.1 74%

10HP 19.9 78% 15.1 59%

* Data appicable for standard air cooled units

34

12HP 20.9 69% 15.6 51%

14HP 19.9 55% 15.5 43%

16HP 20.1 49% 15.6 38%

18HP 20.2 44% 15.6 34%


advanced VRV ® technologies:

3 4 2

2

1

1

Iron

1 Reluctance Brushless DC Compressor ››

››

››

The reluctance brushless DC motor provides significant increases in efficiency compared to conventional AC inverter motors, simultaneously using 2 different forms of torque (normal and reluctance torque) to produce extra power from small electric currents. The motor comprises powerful neodymium magnets, that efficiently generate high torque. These magnets make a major contribution to the energy saving characteristics of the motor. High thrust mechanism (VRV® heat pump) By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound level.

35

Rotating Stator Field

Neodymium Magnet

“Normal” torque Reluctance torque

Suction Low pressure side

Scroll Discharge

High pressure side

Reluctance DC Motor


Sine Wave DC Inverter 2 Optimizing the sine wave curve, results in smoother motor rotation and improved motor efficiency.

3 DC Fan Motor

DC motor efficiency 100

The use of a DC fan motor offers substantial improvements in operating efficiency compared to conventional AC motors, especially during low speed rotation.

(comparison with a conventional AC motor)

Efficiency (%)

80

DC fan motor structure

60 40 AC motor

20 0

200 300 400 500 600 700 800 900 1000 Motor speed (rpm)

Standard heat exchanger

4 e-Pass Heat Exchanger Optimization of the path layout of the heat exchanger prevents heat transferring from the overheated gas section towards the sub cooled liquid section - a more efficient use of the heat exchanger.

OUT 45°C

IN 85°C

e-pass heat exchanger

OUT 45°C

IN 85°C

55°C

27°C

27°C

55°C

27°C

60°C

27°C

50°C

27°C

55°C

27°C

55°C

37°C

OUT 45°C

43°C

OUT 45°C

Power

5 i-Demand Function The newly introduced current sensor minimizes the difference between the actual power consumption and the predefined power consumption.

consumption (KVV)

In cooling mode, the heat exchanger of the condensor is improved. This means an improvement of COP by 3%.

8:00

12:00

16:00 Time

36

20:00



REYAQ-P

VRVIII heat recovery, with connection to heating only hydrobox

›› The total solution VRV –– Cooling, heating, ventilation and hot water from a single system –– Virtually free hot water production from recovered heat in cooling operation –– Total Coefficient of Performance (COP) approaching 9 in simultaneous cooling & heating operation

High ESP Fans SHR =1

High sensible mode

›› … and other benefits of Daikin VRV® III Heat Recovery technology

Cooling 22

Extracted heat 22

Heating

Hot Water

VRV® heat recovery system

Ventilation

Air Curtain

Daikin has been the market leader in variable refrigerant flow systems for the last twenty-five years and benefits from a large experience in energy efficient hot water systems based on heat pump technology. The Daikin VRV® total solution provides a single point of contact for the design and maintenance of your integrated climate control system. Our heat recovery approach is a year-round solution: even when the outside temperature is 0ºC or below, our total solution will still be cooling interior spaces in which people or equipment are generating heat. This heat will be recovered to produce hot water or to heat spaces that are below optimal temperature. Our wide product portfolio enables you to select the right mix of equipment and technology to ensure that you achieve the optimal balance of temperature, humidity and air freshness for the perfect comfort zone with maximum energy efficiency and cost effectiveness. 38


REYAQ-P

VRVIII heat recovery, with connection to heating only hydrobox

A highly efficient and flexible solution

All components integrated

45°C - 75°C

OR EKHWP 45°C - 75°C

EKHTS

25°C - 45°C

25°C - 75°C

REYAQ-P

HXHD125A

100% thermo dynamic energy High performance in 3 steps: Outdoor

1. The outdoor unit extracts heat from the ambient outdoor air.

This heat is transferred to the hydrobox via R-410A refrigerant. 2. The indoor unit receives the heat and further increases the temperature with R-134a refrigerant. 3. The heat is transferred from the R-134a refrigerant circuit to the water circuit. Thanks to the unique cascade compressor approach, water temperatures of 80° C can be reached without using an additional back-up heater.

39

Step

1

Indoor Step

expansion valve

2

Step

3

heat exchanger valve

compressor


REYAQ-P

The height difference between the outdoor unit’s and indoor units’ installation can be up to 40 m. The maximum distance from the first branch to an indoor unit is 40 m. Branch selectors (BS units) are not taken into account, as their installation does not influence the piping design.

1

40m maximum

100m Actual piping length

VRV® offers an extended piping length of 100 m (120 m equivalent piping length) with a total system piping length of 300 m.

40m Level difference between indoor and outdoor units

flexible Piping design

15m Level difference between indoor units

VRVIII heat recovery, with connection to heating only hydrobox

Heat recovery Outdoor unit Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Indoor index Min. connection Nom. Max. HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Hot water Min.~Max. production Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Discharge gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

HP kW kW kW kW

mm kg dBA dBA °CDB °CWB °CDB °CDB mm mm mm m m m Hz/V A

REYAQ10P 10 28 31.5 7.09 7.38 3.95 4.27 21 125 250 325

REYAQ12P 12 33.5 37.5 8.72 8.84 3.84 4.24 26 150 300 390

REYAQ14P 14 40 45 11.4 11.0 3.51 4.09 30 175 350 455 1,680x1,300x765

331 78 58

339 80 60

83 62

Nom. Colour Material HeightxWidthxDepth Dimensions Unit Weight Unit Sound pressure Nom. level Night quiet mode Level 1 Operation range Heating Ambient Min.~Max. Water side Min.~Max. Domestic hot Ambient Min.~Max. water Water side Min.~Max. Refrigerant Type Refrigerant circuit Gas side diameter Liquid side diameter Water circuit Piping connections diameter Heating water system Water volume Min.~Max. Power supply Phase/Frequency/Voltage Current Recommended fuses

84 63

-5~43 -20~15.5 -20~20 / 24 (1) (Space heating) -20~43 (Domestic hot water) R-410A 9.52 22.2

12.7 28.6 19.1

22.2 100 300 40 (Outdoor unit in highest position)/ 40 (Indoor unit in highest position) 3~/50/380-415

25

40

(1) Field setting

Indoor unit Heating capacity Casing

REYAQ16P 16 45 50 14.1 12.8 3.19 3.91 34 200 400 520

HXHD125A 14.0 Metallic grey Precoated sheet metal 705x600x695 92 42 (1) / 43 (2) 38 (5) -20~20 / 24 (3) 25~80 -20~43 45~75 R-134a 12.7 9.52 G 1” (female) 20~200 1~/50/220-240 20

kW

mm kg dBA dBA °C °C °CDB °C mm mm inch l Hz/V A

(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting

40



REYQ-P8/P9 REYHQ-P9

VRV® III heat recovery Small footprint & high COP combinations

›› Functionality unique in the market –– Continuous heating even during defrost –– Continuous operation during cool-heat switch –– Cooling & Heat Recovery operation range down to -20°C in technical cooling mode

Automatic refrigerant charging Refrigerant leak check

›› Highest efficiency on the market –– Total COP over 9 in simultaneous cooling-heating operation

High ESP Fans SHR =1

›› Unprecedented installation flexibility –– Longest piping lengths in the market –– Up to 64 indoor units –– Up to 200% connection ratio –– Up to 78 Pa ESP on outdoor fan

High sensible mode

Continuous heating during defrost

Individual comfort thanks to VRV®III BS box

››

Individual change over from cooling to heating or vice versa of the indoor units is possible. This means that all indoor units who do not change over continue to provide optimum comfort for the users during this process.

High comfort -- No cold draft during defrost & oil return -- No big temperature fluctuations in the room ›› Higher integrated heating capacity (indoor units continue to deliver heating) -- Continuous heating during defrost results in a higher integrated heating capacity and much higher comfort levels for the users.

VRV®III With the VRV®III BS box, the other indoor units can keep heating while the target indoor units are switched from cooling to heating.

* O nly available for multi combination heat recovery systems (REYQ18-48P8/9, REYHQ16-24P) VRV®III Heat recovery

2 3

1

only 1 outdoor coil at a time performs defrost operation

fan off continuous heating (reduced capacity)

hot start

full heating capacity

42


REYQ-P8/P9 REYHQ-P9 + 11%

VRV® III heat recovery Small footprint & high COP combinations

4.30

COP

4.20

Did you know that…

+ 11%

4.40

4.10 3.90 3.80 High COP range

3.70 3.60

Small footprint range

16

20

22

24

… the Daikin VRV® system regularly delivers a Coefficient of Performance (COP) of 4 or more, meaning that it produces four units of heat energy for every one unit of electrical energy used. However, when operating in heat recovery mode, the COP can be has high as 10, making the Daikin VRV® system the most advanced of its kind.

Top energy efficiency in Daikin heat recovery range, thanks to the redesigned 8HP modular unit and newly developed 12HP high COP modular unit Ideal situation when heating and cooling

10 8 7

COP

6

HEAT RECOVERY • HIGH COP COMBINATION • SMALL FOOTPRINT COMBINATION

5

4

3 2

50°

1 0

Cooling 43°CDB

40°

20

40

Only cooling

30°

0° -10° -20° -30°

-5°CWB

-20°CWB

80

-5°CDB

-20°CWB

-20°CDB

After the first branch, the difference between the longest piping length and the shortest piping length can be maximum 40m, provided that the longest piping length amounts to maximum 90m. For more information, please contact your local Daikin dealer. Branch selectors (BS units) are not taken into account, as their installation does not influence the piping design.

1 1

43

90m maximum

In case the outdoor unit is located above the indoor unit the height difference is 50m standard. It can be extended to 90m1. In case the outdoor unit is located below the indoor unit, the height difference is 40m standard. Height differences up to maximum 90m are possible1.

15m Level difference between indoor units

VRV® offers an extended piping length of 165m (190m equivalent piping length) with a total system piping length of 1,000m.

165m Actual piping length

flexible Piping design

40m (90m1) Level difference between indoor and outdoor units

Note: Heating operation range is defined in Wet Bulb temperature. 15.5°CWB translates to approximately 21~25°C Dry Bulb temperature under usual climate conditions.

100

Only heating

Coefficient of performance of a Daikin VRV® heat recovery system

Cooling & Heating 15.5°CWB Technical Cooling

Heating 10° 15.5°CWB

Technical Cooling

20°

60

50% heating 50% cooling


REYQ-P8/P9 REYHQ-P9

VRV® III heat recovery Small footprint & high COP combinations

Heat recovery - small footprint combinations Outdoor system Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Discharge gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor system System

Outdoor unit module HeightxWidthxDepth Dimensions Unit Weight Unit Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

REYQ10P8 10 28.0 31.5 7.09 7.38 3.95 4.27 21

78

331 78

HP kW kW kW kW

dBA mm mm mm mm m m m Hz/V A

HP kW kW kW kW

REYQ12P9 12 33.5 37.5 8.72 8.84 3.84 4.24 26 1,680x1,300x765

REYQ14P8 14 40.0 45.0 11.4 11.0 3.51 4.09 30

80 60 -20 (1) / -5~43 -20~15.5 R-410A

83 62

9.52 19.1 15.9

84 63

12.7 28.6

22.2 19.10

22.2

165 1,000 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 3~/50/380-415 25

20 REYQ18P9 REYQ20P9 REMQ8P9 REMQ10P8 18 20 50.4 55.9 56.5 62.5 12.7 14.9 13.4 15.2 3.97 3.75 4.22 4.11 39 43 81

REYQ22P8 REMQ10P8 REMQ12P8 22 61.5 69.0 17.0 17.1 3.62 4.04 47

REYQ16P8 16 45.0 50.0 14.1 12.8 3.19 3.91 34 339

58

mm mm mm m m m Hz/V A

Outdoor unit module 1 Outdoor unit module 2

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound power level Cooling Nom Piping Liquid OD connections Gas OD Discharge gas OD Oil equalizing OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

REYQ8P9 8 22.4 25.0 5.20 5.71 4.31 4.38 17

mm kg dBA dBA °CDB °CWB

Outdoor unit module 1 Outdoor unit module 2

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound power level Cooling Nom Piping Liquid OD connections Gas OD Discharge gas OD Oil equalizing OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor system System

HP kW kW kW kW

REYQ24P8 REMQ12P8

REYQ26P8 REMQ10P8

24 67.0 75.0 19.2 18.9 3.49 3.97 52

26 73.0 81.5 21.8 20.6 3.35 3.96 56 83

40

REYQ28P8 REYQ30P8 REYQ32P8 REMQ12P8 REMQ14P8 REMQ16P8 REMQ16P8 28 30 32 78.5 85.0 90.0 87.5 95.0 100 23.8 26.6 28.4 22.3 24.2 25.8 3.29 3.19 3.16 3.92 3.87 60 64

15.9

19.1

28.6

34.9

22.2

28.6 19.1 165 1,000 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 3~/50/380-415 50 60

45 REYQ34P9 REYQ36P9 REMQ8P9 REMQ10P8 34 36 95.4 101 107 113 26.9 29.1 26.3 28.1 3.55 3.47 4.07 4.02

REYQ38P8 REMQ10P8 REMQ12P8 38 107 119 31.2 30.0 3.43 3.96

REYQ40P8 REMQ12P8

REYQ42P8 REMQ10P8

40 112 125 33.4 31.8 3.35 3.93

42 118 132 35.8 33.5 3.29 3.94

70

REYQ44P8 REYQ46P8 REMQ12P8 REMQ14P8 REMQ16P8 44 46 124 130 138 145 38.0 40.8 35.2 37.1 3.26 3.18 3.92 3.90

REYQ48P8 REMQ16P8 48 135 150 42.6 38.7 3.16 3.87

64 dBA mm mm mm mm m m m Hz/V A

84

85 19.1

34.9

41.3 28.6

80 REMQ8P9

mm kg °CDB °CWB

34.9 19.1 165 1,000 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 3~/50/380-415 90 100 REMQ10P8 1,680x930x675

204

REMQ12P8 254 -20 (1) / -5~43 -20 ~ 15.5 R-410A 3~/50/380-415

Hz/V A

(1) Field setting

44

110

REMQ14P8 REMQ16P8 1,680x1,240x765 334


REYQ-P8/P9 REYHQ-P9

VRV® III heat recovery Small footprint & high COP combinations

Heat recovery - high COP combinations Outdoor system System

REYHQ16P Outdoor unit module 1 Outdoor unit module 2

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit module HeightxWidthxDepth Dimensions Unit Weight Unit Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

REYHQ20P

REYHQ22P REMQ10P8 REMHQ12P8 22 61.5 69.0 16.0 16.3 3.84 4.24 47

REMQ8P9 HP kW kW kW kW

REMQ8P9 16 45.0 50.0 10.5 11.5 4.29

20 56.0 62.5 13.9 14.3 4.04 4.36

dBA dBA mm mm m m Hz/V A

34 82 62 12.7

43 85 64

24 67.0 75.0 17.2 17.2 3.89 4.37 52 87 66

15.9 28.6

34.9

1,000 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 3N~/50/380-415 63

50 REMQ8P9

mm kg °CDB °CWB

REYHQ24P REMHQ12P8

REMQ10P8 1,680x930x765

204

254 -5~43 -20~15 R-410A 3~/50/380-415 -

Hz/V A

45

80 REMHQ12P8 1,680x1,300x765 331

3N~/50/380-415 40


RXYQ-P9 RXYHQ-P9

Automatic refrigerant charging Refrigerant leak check High ESP Fans SHR =1

High sensible mode

VRV®III heat pump, small footprint & high COP combinations

›› Unprecedented installation flexibility –– Up to 1000 m of total piping –– Up to 90 m elevation difference between indoor and outdoor units –– Up to 165 m between indoor and outdoor units –– Up to 64 indoor units –– Up to 200% connection ratio –– Up to 78 Pa ESP on outdoor fan & indoor installation ready ›› Installation & legislation friendly –– Automatic refrigerant charging –– Refrigerant leak check

After the first branch, the difference between the longest piping length and the shortest piping length can be maximum 40m, provided that the longest piping length amounts to maximum 90m. * For more information, please contact your local Daikin dealer.

46

90m maximum

15m Level difference between indoor units

In case the outdoor unit is located above the indoor unit the height difference is 50m standard. It can be extended to 90m*. In case the outdoor unit is located below the indoor unit, the height difference is 40m standard. Height differences up to maximum 90m are possible*.

165m Actual piping length

VRV® offers an extended piping length of 165m (190m equivalent piping length) with a total system piping length of 1,000m.

40m (90m*) Level difference between indoor and outdoor units

flexible Piping design


RXYQ-P9 RXYHQ-P9

VRV®III heat pump, small footprint & high COP combinations

top energy efficiency

The high COP combination has a top energy efficiency within the Daikin heat pump range. It is up to 16% more efficient. compared to the small footprint combination. +16% HP combination COP EER combination COP EER

High COP combination Small footprint combination

12

16

18

20

22

12 4.37 3.89 12 3.97 3.48

8+8 4.50 4.29 16 3.88 3.17

8 + 10 4.27 4.00 18 3.69 3.02

8 + 12 4.42 4.05 8 + 12 4.18 3.80

10 + 12 4.24 3.84 10 + 12 4.04 3.62

24

26

28

30

32

34

36

8 + 8 + 8 8 + 8 + 10 8+10+10 8+10+12 8+12+12 10+12+12 12+12+12 4.50 4.34 4.44 4.31 4.40 4.29 4.37 4.29 4.09 4.12 3.96 3.99 3.85 3.89 12 + 12 8 + 18 10 + 18 12 + 18 14 + 18 16 + 18 18 + 18 3.97 3.94 3.83 3.81 3.83 3.79 3.69 3.49 3.41 3.26 3.20 3.11 3.09 3.02

Seasonal Performance The European 20/20/20 targets press energy users to drastically cut energy consumption and improve energy efficiency of buildings. In order to have a good view on the yearly running costs & CO2 emissions of your air conditioning system, a seasonal performance indication is required. The current standards do not provide real guidance on the yearly performance of a VRV® system, as only one nominal point in cooling and one nominal point in heating is published. To correct this, a more accurate calculation method – the Seasonal Efficiency Ratio/Seasonal coefficient of performance - or SEER/SCOP – is being developed by the EU, in view of the upcoming Eco Design Directive for air conditioners > 12 kW. This will require AC manufacturers to provide yearly performance data (SEER/SCOP).

Daikin leads the market by publishing seasonal performance data Until the new calculation method is known, Daikin already publishes ESEER and APF values today. ESEER The ESEER values provide a clear view on the part-load cooling performance of VRV® III. Thus enabling estimation of the annual power consumption in cooling mode. The ESEER values published for air-cooled VRV® systems allow a comparison with other air-cooled systems only; when comparing with air-cooled chillers, auxiliary power consumption of circulation pumps still needs to be added to the chiller performance. 1 ESEER: formula: ESEER= 0,03* EERA + 0,33* EERB + 0,41* EERC + 0,23* EERD

condition

load

A B C D

100% 75% 50% 25%

indoor temperature conditions: 19°CWB/27°CDB

ambient temperature 35°CDB 30°CDB 25°CDB 20°CDB

For chillers the outdoor power input is taken into account (excluding pumps and indoor units), for VRV® the outdoor power input is taken into account (excluding indoor units).

APF The Annual Performance Factor or APF is the Japanese seasonal performance benchmark for VRF systems, which allows users to gauge the true seasonal performance of a VRF system in both heating and cooling. 2 APF: Formula: Accumulated heating & cooling loads (kWh) (1*2) / accumulated power input in heating and cooling (kWh) (2*3) RXYQ-P9 EER ESEER APF

5 3.98 6.13 5.0

8 4.29 6.61 5.4

10 3.77 5.83 5

12 3.48 5.37 4.6

14 3.23 4.96 4.6

1 Load depending on outdoor

5

10

200

Below 17°C no cooling required

15

20

25

Ambient temperatures (°C)

Occurence (h)

Load (kW) 0

18 3.02 4.67 4.2

20 3.80 5.89 4.9

22 3.62 5.59 4.8

24 3.49 5.38 4.6

26 3.41 5.28 4.6

28 3.26 5.09 4.5

30 3.20 4.95 4.4

32 3.11 4.81 4.4

34 3.09 4.78 4.3

36 3.02 4.67 4.2

38 3.43 5.31 4.6

30

35

Heating period

40 3.34 5.18 4.5

42 3.28 5.07 4.4

44 3.25 5.03 4.4

46 3.17 4.93 4.4

48 3.14 4.84 4.3

50 3.08 4.76 4.3

52 3.07 4.74 4.3

54 3.02 4.67 4.2

3 Power input curves

2 Temperature occurence (Tokyo)

temperature (office) Above 11°C no heating required

16 3.17 4.89 4.4

Based on: - Tokyo climate - 6 days/week - From 8 AM to 8 PM

Cooling period

100

0

5

10

15

20

25

Ambient temperatures (°C)

30

35

kW

-5 0

5

10

15

20

25

30

35

40

Ambient temperatures (°C)

1 ESEER: Conditions: indoor temp. 27°C DB/19°C WB; outdoor temp. 35°C; 30°C; 25°C; 20°C. Formula: EER at 35°C * 0.03 + EER at 30°C * 0.33 + EER at 25°C * 0.41 + EER at 20°C * 0.23. For chillers the outdoor power input is taken into account (excluding pumps, cooling towers, indoor units, …), for VRV® the outdoor power input is taken into account (excluding indoor units). 2 APF: Formula: Accumulated heating & cooling loads (kWh) (1*2) / accumulated power input in heating and cooling (kWh) (2*3)

47


RXYQ-P9 RXYHQ-P9

VRV®III heat pump, small footprint & high COP combinations

Heat pump - small footprint combinations Outdoor unit System Capacity range Cooling capacity Heating capacity Power input - 50Hz

Outdoor unit module 1 Nom. Nom. Cooling Heating

Nom. Nom.

EER COP APF Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit System

mm kg dBA dBA °CDB °CWB mm mm m m m Hz/V A

HP kW kW kW kW

dBA dBA mm mm m m m Hz/V A

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP APF Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

HP kW kW kW kW

RXYQ10P9 RXYQ12P9 RXYQ10P9 RXYQ12P9 10 12 28.0 33.5 31.5 37.5 7.42 9.62 7.70 9.44 3.77 3.48 4.09 3.97 5 21 26 1,680x930x765 240

187

RXYQ14P9 RXYQ14P9 14 40.0 45.0 12.4 11.30 3.23 3.98 4.6 30

78 57

RXYQ16P9 RXYQ16P9 16 45.0 50.0 14.2 12.90 3.17 3.88 4.4 34 1,680x1,240x765 316

80 60

58

9.52 19.1

15.9

12.7 22.2

RXYQ18P9 RXYQ18P9 18 49.0 56.5 16.2 15.30 3.02 3.69 4.2 39 324 83 63

20 55.90 62.50 14.71 14.95 3.80 4.18 4.9 43

RXYQ22P9 RXYQ10P9 RXYQ12P9 22 61.50 69.00 16.99 17.08 3.62 4.04 4.8 47 83

62

RXYQ24P9 RXYQ12P9

RXYQ26P9 RXYQ8P9

RXYQ28P9 RXYQ10P9

24 67.00 75.00 19.20 18.89 3.49 3.97

26 71.40 81.50 20.94 20.69 3.41 3.94

28 77.00 88.00 23.62 22.98 3.26 3.83 4.5 60

4.6 52

56

63

RXYQ30P9 RXYQ32P9 RXYQ12P9 RXYQ14P9 RXYQ18P9 30 32 82.50 89.00 94.00 102.00 25.78 28.62 24.67 26.63 3.20 3.11 3.81 3.83 4.4

RXYQ34P9 RXYQ16P9

RXYQ36P9 RXYQ18P9

34 94.00 107.00 30.42 28.23 3.09 3.79 4.3

36 98.00 113.00 32.45 30.62 3.02 3.69 4.2

64

64

34.9 165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 63

50

86 66

65 19.1

15.9

RXYQ40P9 RXYQ10P9 RXYQ12P9 40 111.00 126.00 33.23 32.39 3.34 3.89 4.5

40

85

28.6

38 105.00 119.00 30.61 30.13 3.43 3.95 4.6

15.9 28.6

165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 25

16

RXYQ38P9 RXYQ8P9

Outdoor unit module 1 Outdoor unit module 2

RXYQ8P9 RXYQ8P9 8 22.4 25.0 5.22 5.56 4.29 4.50 5.4 17

-5.0~43.0 -20~15 R-410A

RXYQ20P9 RXYQ8P9

Outdoor unit module 1 Outdoor unit module 2

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP APF Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit System

HP kW kW kW kW

RXYQ5P9 RXYQ5P9 5 14.0 16.0 3.52 4.00 3.98 4.00 5.0 10 1,680x635x765 159 72 54

RXYQ42P9 RXYQ12P9

RXYQ44P9 RXYQ8P9

RXYQ46P9 RXYQ10P9

42 116.00 132.00 35.37 34.20 3.28 3.86

44 120.00 138.00 36.92 35.94 3.25 3.84 4.4

46 126.00 145.00 39.75 38.26 3.17 3.79

RXYQ48P9 RXYQ50P9 RXYQ12P9 RXYQ14P9 RXYQ18P9 48 50 132.00 138.00 151.00 158.00 42.04 44.81 39.95 41.91 3.14 3.08 3.78 3.77 4.3

41.3

80 RXYQ52P9 RXYQ16P9

RXYQ54P9 RXYQ18P9

52 143.00 163.00 46.58 43.47 3.07 3.75

54 147.00 170.00 48.68 45.95 3.02 3.70 4.2

64 dBA dBA mm mm m m m Hz/V A

86 66

87 67 19.1 41.3 165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 100

48

88 68

125


RXYQ-P9 RXYHQ-P9

VRV®III heat pump, small footprint & high COP combinations

Heat pump - high COP combinations Outdoor system System Capacity range Cooling capacity Heating capacity Power input - 50Hz

Nom. Nom. Cooling Heating

Nom. Nom.

EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor system System

RXYHQ12P9 RXYHQ12P9 12 33.5 37.5 8.61 8.58 3.89 4.37 26 1,680x1,240x765 281 80 60 -5.0~43.0 -20.0~15.0 R-410A 12.7 28.6 165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 25

Outdoor unit module 1 HP kW kW kW kW

mm kg dBA dBA °CDB °CWB mm mm m m m Hz/V A

Outdoor unit module 1 Outdoor unit module 2 Outdoor unit module 3

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit module HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

HP kW kW kW kW

dBA dBA mm mm m m m Hz/V A

RXYHQ16P9 RXYHQ18P9 RXYHQ20P9 RXYHQ22P9 RXYHQ24P9 RXYHQ26P9 RXYHQ28P9 RXYHQ30P9 RXYHQ32P9 RXYHQ34P9 RXYHQ36P9 RXYQ8P9 RXYQ10P9 RXYQ8P9 RXYQ10P9 RXYHQ12P9 RXYQ8P9 RXYQ10P9 RXYHQ12P9 RXYQ8P9 RXYQ10P9 RXYHQ12P9 RXYQ8P9 RXYQ10P9 RXYHQ12P9 16 18 20 22 24 26 28 30 32 34 36 45.00 49.00 55.90 61.50 67.00 71.40 77.00 82.50 89.00 94.00 98.00 50.00 56.50 62.50 69.00 75.00 81.50 88.00 94.00 102.00 107.00 113.00 10.49 12.25 13.80 16.02 15.62 17.46 18.69 20.83 22.31 24.42 25.19 11.11 13.23 14.14 16.27 16.67 18.78 19.82 21.81 23.18 24.94 25.86 4.29 4.00 4.05 3.84 4.29 4.09 4.12 3.96 3.99 3.85 3.89 4.50 4.27 4.42 4.24 4.50 4.34 4.44 4.31 4.40 4.29 4.37 34 39 43 47 52 56 60 64 82 83 85 60 61 62 63 64 65 12.7 15.9 19.1 28.6 34.9 41.3 165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 50 63 80 RXYQ8P9

mm kg dBA dBA °CDB °CWB

RXYQ10P9 1,680x930x765

187

240 78

57

58 -5.0~43.0 -20~15 R-410A 3N~/50/400 25

Hz/V A

49


RTSYQ-P

Automatic refrigerant charging Refrigerant leak check High ESP Fans SHR =1

VRV®III heat pump, optimised for heating

›› Unprecedented functionality and performance –– Genuine two-stage compression –– Heating operation guaranteed down to ­-25°C –– Constant capacity down to -5°C –– COP > 3 down to -15°C –– 80% of capacity available down to -20°C –– 50% shorter start-up and defrost times

High sensible mode

COP for a 10HP unit

High COP at low ambients

4.00

The use of two stage compression technology results in improved energy saving performance at low ambients, with a COP of more than 3.0 at -10°C outdoor ambient for the entire range (up to 3.8 for a 10HP unit). Annual power costs are therefore, considerably lower than those of the standard heat pump.

3.00 COP

mp

®

VRV dard

2.00

t pu hea

Stan

1.00 0.00 -25

-20

-15

-10

-5

0

5

10

Outdoor temp. (WB°)

WIDE HEATING OPERATION RANGE

HEATING

COOLING

50

VRV  III-C +43 °CDB ®

40 outdoor temperature

VRV®III-C is the first system on the market with a standard operation range down to -25 °CWB outdoor ambient in heating and can also provide cooling down to - 5 °CDB outdoor ambient.

30 20

VRV® III-C +15.5 °CWB

VRV® +43 °CDB

VRV® +15.5 °CWB

10 -5

-5 °CDB

-5 °CDB

-10 -15 -20 °CWB

-20 -25 °CWB

-25

Heating capacity 10HP outdoor unit

STABLE heating capacity

(kW) heating capacity

35

VRV®III-C has a stable heating capacity, even in low ambients, making it suitable for single source heating. The heating capacity is 130% in comparison with the standard VRV® heating capacity under similar conditions

30 25

standard heat pump

20 15 10 5 0

50

-25

-20

-15 -10 -5 Outdoor temp. (°CWB)

0

5

10


RTSYQ-P

VRV®III heat pump, optimised for heating

High heat up speed Heat up time is dramatically reduced, particularly under low ambient conditions. The required time for the indoor unit heat exchanger discharge temperature to reach 40°C has been reduced by 50%. °C

Start heating operation

60 35 50

30

30 20

25

10 Standard heat pump

0

20

-5

0

5 6 10 Elapsed time (min.)

Indoor heat exchanger temperature standard heat pump X +10

15 -20

Indoor heat exchanger temperature VRV®III-C

Indoorpositie temperatureblauwe VRV®III-C lijnen:

50% reduction

-10

Indoor temperature °C

Discharge temperature (°C)

40

14 15

20

Indoor temperature standard heat pump * Field test data in Japan with 14 HP unit (Akita City Jan 2006)

Short defrost time The time required for defrost is reduced to 4 minutes – less than half that of the standard VRV®III system (10 minutes), leading to a more stable interior indoor temperature and considerably improved comfort levels. * Field test data in Japan with 10 HP unit (Akita City Jan 2006)

Heating capacity

TWO STAGE COMPRESSION High

Liquid injection

Pressure

Gas-liquid separator Middle

Gas injection

Low

Evaporator capacity

Input power

Enthalpy

51

Two stage compression technology enables the system to create higher pressures resulting in a higher heating capacity under low ambient conditions. The second inverter compressor (located in the function unit) is specially designed to provide higher pressures. After heat is exchanged in the indoor unit, gas and liquid are separated at the gas-liquid separator. This enables the refrigerant in gas condition to be recovered and transmitted direct to the high pressure compressor.


RTSYQ-P

VRV®III heat pump, optimised for heating

90m maximum

165m Actual piping length

VRV®III-C offers an extended piping length of 165m (190m equivalent piping length) with a total system piping length of 500m. If the outdoor unit is located above the indoor unit, the height difference is 50m. If the outdoor unit is located below the indoor unit, the height difference is 40m. The distance between the outdoor unit and the function unit should be a maximum of 10m (13m equivalent piping length). After the first branch, the difference between the longest piping length and the shortest piping length can be a maximum 40m, provided that the longest piping length amounts to a maximum of 90m.

50m Level difference between indoor and outdoor units 15m Level difference between indoor units

Flexible piping design

Heat pump Outdoor system System

Outdoor unit module 1 Outdoor unit module 2 Function unit

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound pressure level Cooling Max./Nom. Piping Liquid OD connections Gas OD Oil equalizing OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

RTSYQ10P RTSQ10P

RTSYQ14P RTSQ14P -

10 28.0 (1) 31.50 (2) / 28.0 (3) 7.90 7.70 3.54 4.09 21 62/60 9.52 22.2

14 40.0 (1) 45.0 (2) / 40.0 (3) 12.6 11.3 3.17 3.98 30 63/61

RTSYQ16P RTSQ16P

RTSYQ20P RTSQ8P RTSQ12P

16 45.0 (1) 50.0 (2) / 45.0 (3) 14.9 12.9 3.02 3.88 34

20 55.9 (1) 62.5 (2) / 56.0 (3) 15.4 15.3 3.63 4.01 43

BTSQ20P HP kW kW kW kW

dBA mm mm mm m m m Hz/V A

65/63 12.7

15.9 28.6

-

19.1

165 500 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3~/50/380-415 35 40

25

50

(1) Cooling: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (2) Heating: Indoor temp. 20°CDB; outdoor temp. 7°CDB,6°CWB; equivalent piping length: 7.5m; level difference: 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (3) Heating: Indoor temp. 20°CDB; outdoor temp. -10°CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units

Outdoor unit module HeightxWidthxDepth Dimensions Unit Weight Unit Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

RTSQ8P mm kg °CDB °CWB Hz/V A

RTSQ10P 1,680x930x765

205

RTSQ12P 257

RTSQ14P RTSQ16P 1,680x1,240x765 338 344

BTSQ20P 1,570x460x765 110

-5 ~ 46 -25 ~ 15.5 R-410A 3~/50/380-415 25

52

35

40

20



RXYRQ-P

VRV®III heat pump, with connection to stylish indoor units

›› Widest portfolio of connectable indoor units on the market: 25 types of indoor units to choose from ›› Have in one system: –– Quietest indoor units on the market – down to 19 dB(A) –– Units with award-winning design – the Daikin Emura –– Units with unique functionality – radiation function of the Nexura –– Units with unique power – VRV concealed ceiling units with up to 270 Pa of ESP and 28 kW of nominal cooling capacity

NEW

High ESP Fans

Including connection to

n to nectio n o c g cludin ura

Nexura

In

More info

rmation in

the Resid

n Em

Daiki

in ation

inform More

ential Cata

logue

FXSQ-P VRV® indoor unit FTXG-J

FVXS-F

BPMKS967B3

FTXS-G

FTXG-J FXFQ-P9 VRV® indoor unit

FVXG-K BPMKS967B2

54

the

ue

talog ial Ca

ent Resid


RXYRQ-P

VRV®III heat pump, with connection to stylish indoor units

The minimum piping length between the outdoor unit and the first branch is 5 m. The minimum piping length between the BP box and the indoor unit is 2 m, the maximum length is 15 m. After the first branch, the longest piping length is 50m, or 70m in case the first branch contains only VRV indoor units. The height difference between the outdoor and indoor unit or BP box can be maximum 50 m, 40 m if the outdoor is below the indoors.

5m minimum length

up to 70m maximum

The VRV® heat pump with connection to stylish indoor units offers a total system piping length of 250 m.

15m Level difference between indoor units

50m/40m Level difference between indoor and outdoor units

piping design

2m minimum length 15m maximum length

Connectable indoor units Daikin Emura - Wall mounted unit Wall mounted unit Nexura - Floor standing unit Floor standing unit Flexi type unit Slim concealed ceiling unit Concealed ceiling unit 4-way blow ceiling mounted cassette (600x600) Round flow cassette Ceiling suspended cassette All VRV indoor units in all available classes

15 class

20 class

25 class

35 class

42 class

50 class

60 class

71 class

CTXS15K -

FTXS20K FTXS20J -

FTXG25JW/A FTXS25K FTXS25J FVXG25K FVXS25F FLXS25B FDXS25E FFQ25B9V -

FTXG35JW/A CTXS35K FTXS35J FVXG35K FVXS35F FLXS35B FDXS35E FBQ35C FFQ35B9V FCQG35F FHQ35B

FTXS42J -

FTXG50JW/A FTXS50J FVXG50K FVXS50F FLXS50B FDXS50C FBQ50C FFQ50B9V FCQG50F FHQ50B

FTXS60G FDXS60C FBQ60C FFQ60B9V FCQG60F FHQ60B

FTXS71G -

Heat pump Outdoor unit Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

HP kW kW kW kW

mm kg dBA dBA °CDB °CWB mm mm m m Hz/V A

RXYRQ8P 8 22.4 25.0 5.09 5.56 4.40 4.50 17

RXYRQ10P 10 28.0 31.5 7.11 7.70 3.94 4.09 21 1,680x930x765

187

RXYRQ12P 12 33.5 37.5 9.23 9.44 3.63 3.97 26

RXYRQ14P 14 40.0 45.0 11.40 11.30 3.61 3.98 30

240

316

78 57

RXYRQ16P 16 45.0 50.0 13.50 12.90 3.33 3.88 34 1,680x1,240x765

324 83 63

80 60

58

RXYRQ18P 18 49.0 56.5 15.30 15.30 3.20 3.69 39

-5.0~43.0 -20.0~15.0 R-410A 9.52 19.1

12.7 22.2

15.9 28.6

250 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 25

55

40


RXYSQ-P8

VRV®III-S heat pump

›› Compact unit yet providing many of the Daikin VRV® III benefits –– High efficiency –– Low noise –– Demand operation –– Automatic charging

Automatic refrigerant charging

›› Two systems in one –– Same outdoor unit can connect either VRV indoor units or Split & SkyAir indoor units

Wide range of indoor units Either connect VRV® indoor units or stylish indoor units as Daikin Emura, Nexura, ...

FCQ-C8 FVXS-F

FTXG-J

BPMKS967B3

BPMKS967B2

FTXS-G

FBQ-C

FTXG-J FVXG-K

BPMKS967B2 FXSQ-P

FXFQ-P9

FXLQ-P

FXLQ-P

FXSQ-P

FXAQ-P

FXFQ-P9

* VRV® indoor units and stylish indoor units cannot be combined.

56


RXYSQ-P8

VRV®III-S heat pump

Flexible piping design The VRV®III-S provides the long piping length possibilities of 300m total piping when using VRV® indoor units (150m actual / 175m equivalent from outdoor to furthest indoor), or 250m total when using Split or SkyAir indoor units (100m total between outdoor and BP boxes, 80m total between BP boxes and indoor units). The level difference between the outdoor unit and the indoor units can be up to 40m, and up to 50m in case of VRV indoor units and installation of outdoor unit above indoor units. After the first branch, the longest piping length is 40m.

40m maximum

15m Level difference between indoor units

40m Level difference between indoor and outdoor units

50m Level difference between indoor and outdoor units

150m Actual piping length

5m minimum length

2m minimum length 15m maximum length

Heat pump Outdoor unit Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure Cooling Nom. level Heating Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

HP kW kW kW kW

mm kg dBA dBA dBA °CDB °CWB mm mm m m m Hz/V A

RXYSQ4P8V1 4 11.2 12.5 2.81 2.74 3.99 4.56 8 (1) / 6 (2)

RXYSQ5P8V1 RXYSQ6P8V1 RXYSQ4P8Y1 RXYSQ5P8Y1 RXYSQ6P8Y1 5 6 4 5 6 14.0 15.5 11.2 14.0 15.5 16.0 18.0 12.5 16.0 18.0 3.51 4.53 2.89 3.61 4.65 3.86 4.57 2.82 3.97 4.70 3.99 3.42 3.88 3.33 4.15 3.94 4.43 4.03 3.83 10 (1) / 8 (2) 13 (1) / 9 (2) 8 (1) / 6 (2) 10 (1) / 8 (2) 13 (1) / 9 (2) 1,345x900x320 1,345x900x320 120 120 66 67 69 66 67 69 50 51 53 50 51 53 52 53 55 52 53 55 -5~46 -5~46 -20~15.5 -20~15.5 R-410A R-410A 9.52 9.52 15.9 (1) / 19.1 (2) 15.9 (1) / 19.1 (2) 19.1 (1)(2) 15.9 (1) / 19.1 (2) 15.9 (1) / 19.10 (2) 19.1 (1)(2) 150 150 300 (1) / 115 (2) 300 (1) / 135 (2) 300 (1) / 145 (2) 300 (1) / 115 (2) 300 (1) / 135 (2) 300 (1) / 145 (2) 50 (1) / 40 (2) (Outdoor unit in highest position) / 30 (Indoor unit in highest position) 50 (1) / 40 (2) (Outdoor unit in highest position) / 30 (Indoor unit in highest position) 1N~/50/220-240 3N~/50/380-415 32.0 16.0

(1) In case VRV indoor units are connected | (2) In case RA indoor units are connected

57


RQCEQ-P RQYQ-P

Replacement VRV

THE DAIKIN SOLUTION TO R-22 PHASE-OUT Replace your R-22 / R-407C outdoor unit with R-410A technology, but keep your refrigerant piping and in some cases your indoor units1.

replace

1. 2. 3. 4.

Replace outdoor unit Replace BS-boxes (in case of H/R) Replace indoor units (check with your local dealer if needed) The system will automatically clean the piping & charge the correct amount of R-410A refrigerant

KEEP replace * When R-22 indoors are K-series or later, it is possible to keep the indoor units.

replace*

TECHNOLOGIES OF VRV®III-Q? Pressure

A

3.3 MPa

}

3.8 MPa

}

REDUCED PRESSURE As R-22 VRV® systems used to work on a lower pressure than R-410A systems / thus the copper refrigerant piping was also designed for these lower pressures. Therefore the Replacement VRV® (VRV®III-Q) must operate at lower pressures than the standard VRV®III series. However thanks to the sub cool circuit a high efficiency level can be kept even with the lower pressures.

B

~

~

Enthalpy

A Decompression to 3.3MPa(s) R-22 existing piping can be used B Extra sub cool circuit high COP

REFRIGERANT PIPE CLEANING When replacing an air conditioning system, the piping is normally replaced as well since traces of old refrigerant and oil mixed with the oil and refrigerant of the new system can cause the equipment to malfunction.

the outdoor unit and the contamination is deposited in the outdoor unit. Daikin is the first manufacturer in the industry to develop this combination of automatic charging and refrigerant pipe cleaning function.

In order to allow re-use of existing R-22 piping with an R-410A system Daikin developed a technology to capture and retain the contamination left in the refrigerant piping. The refrigerant including the remaining oil from the R-22 system is filtered in

Indoor Temperature sensor

Change over valve

Pressure sensor

Anti-reverse valve

Temperature sensor

Catcher

Contamination is collected by the power of the refrigerant gas

58


RQCEQ-P RQYQ-P

Replacement VRV

INCREASED EFFICIENCY Upgrading an old R-22 system to a Replacement VRV® system will result in increased system efficiency. Efficiency gains of more than 25% can be realized, by virtue of technological developments in heat pump technology and the more efficient R-410A refrigerant. Increased energy efficiency equals lower energy consumption, subsequent lower energy costs and lower CO2 emissions. EER of a 10 HP system

COP of a 10 HP system

4.50

4.50

4.00

4.00

3.50

3.50

3.00

2.00

3.00

3.98

2.50

2.37

3.10

1.50   R-22 R-407C

2.50

4.00 3.00

3.10

2.00  1.50   R-22 R-407C

R-410A VRVIII-Q

40% more efficient

R-410A VRVIII-Q

25% more efficient

R-22: RSXY10KA7 | R-407C: RSXYP10L7 | R-410A: RQYQ10P

R-22: RSXY10KA7 | R-407C: RSXYP10L7 | R-410A: RQYQ10P

ENVIRONMENTAL AWARENESS R-410A not only has a zero ozone depletion potential, it is also proven to be more energy efficient than R-22. FAST INSTALLATION It is not necessary to remove the existing piping and even the indoor units can remain (depending on type of indoor unit). The outdoor unit automatically charges the refrigerant and cleans the refrigerant piping. This unique Daikin feature makes the installation time even shorter.

INCREASE CAPACITY Cooling loads often increase subsequent to the initial installation of the air conditioning system. The Replacement VRV®(VRV®III-Q) enables system capacity to be increased without changing the refrigerant piping (depending on system characteristics).

Example: replace a 10HP VRV® with a 16HP Replacement VRV® unit

10 HP

1.

LIMITED AND PLANNED-DOWNTIME As the refrigerant piping can be maintained the installation is less intrusive and less time consuming than for a completely new system. Moreover, downtime can be carefully planned: whereas if a problem occurs when not enough reclaimed R-22 is available, a long and unplanned downtime can be the result. LIMITED AND PHASED INVESTMENT COST It is possible to spread the various stages of replacement over a certain period of time because the indoor units can remain in most cases. The air conditioning replacement therefore, can be incorporated in the general refurbishment schedule of the building and the investment cost can be spread. A further reduction in installation cost can be achieved by maintaining the old refrigerant copper pipe work. 59

16 HP

2.

1. Keep main piping

2. Add indoor units

NO RESTRICTIONS ON SYSTEM HISTORY As a result of the combined automatic charging and refrigerant pipe cleaning function, it is possible to ensure a clean piping network, even when a compressor breakdown has previously occurred.


RQCEQ-P RQYQ-P

Replacement VRV

›› Get rid of R22 easily! –– Keep old R22 piping –– Keep old indoor units and controllers –– (Daikin K-series and newer in case of heat pump systems) –– Low installation costs –– Low disruption caused by the installation –– High reliability thanks to newest technology

Automatic refrigerant charging High ESP Fans SHR =1

High sensible mode

›› Reduce operating costs by up to 40% ›› Applicable also on non-Daikin R22 VRF systems

Heat recovery Outdoor system System

Outdoor unit module 1 Outdoor unit module 2 Outdoor unit module 3 Outdoor unit module 4

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Discharge gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit module HeightxWidthxDepth Dimensions Unit Weight Unit Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Power supply Phase/Frequency/Voltage

HP kW kW kW kW

dBA mm mm mm m m m Hz/V A

RQCEQ280PY1 RQCEQ360PY1 RQCEQ460PY1 RQCEQ500PY1 RQCEQ540PY1 RQCEQ636PY1 RQCEQ712PY1 RQCEQ744PY1 RQCEQ816PY1 RQCEQ848PY1 RQEQ140P RQEQ180P RQEQ140P RQEQ180P RQEQ212P RQEQ140P RQEQ180P RQEQ212P RQEQ140P RQEQ180P RQEQ140P RQEQ180P RQEQ212P RQEQ180P RQEQ212P RQEQ180P RQEQ212P RQEQ180P RQEQ212P RQEQ212P 10 13 16 18 20 22 24 26 28 30 28.0 36.0 45.0 50.0 54.0 63.6 71.2 74.4 81.6 84.8 32.0 40.0 52.0 56.0 60.0 67.2 78.4 80.8 87.2 89.6 7.04 10.3 12.2 13.9 15.5 21.9 21.2 23.3 27.1 29.2 8.00 10.7 13.4 14.7 16.1 17.7 20.7 21.2 23.1 23.6 3.98 3.48 3.77 3.61 3.48 2.90 3.36 3.19 3.01 2.90 4.00 3.72 3.89 3.80 3.72 3.79 3.80 3.81 3.77 3.79 21 28 34 39 43 47 52 56 60 64 57 61 62 63 64 63 64 65 66 9.52 12.7 15.9 19.1 22.2 25.4 28.6 34.9 19.1 22.2 25.4 28.6 120 300 50 (Outdoor unit in highest position) 3~/50/400 30 40 50 60 70 80 90 RQEQ140P

mm kg dBA °CDB °CWB

RQEQ180P 1,680x635x765 175

54

58 -5~43 -20~15 R-410A 3~/50/380-415

Hz/V

60

RQEQ212P 179 60


RQCEQ-P RQYQ-P

Replacement VRV

Heat pump Outdoor unit System Capacity range Cooling capacity Heating capacity Power input - 50Hz

Outdoor unit module 1 Nom. Nom. Cooling Heating

Nom. Nom.

EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

Outdoor unit System

mm kg dBA dBA 째CDB 째CWB mm mm m m m Hz/V A

Outdoor unit module 1 Outdoor unit module 2

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Current - 50Hz Maximum fuse amps (MFA) Outdoor unit System

HP kW kW kW kW

HP kW kW kW kW

dBA mm mm m m m A

RQYQ140P RQYQ140P 5 14.0 16.0 3.36 3.91 4.17 4.09 10 1,680x635x765 175

RQYQ8P RQYQ8P 8 22.4 25.0 5.24 6.42 4.27 3.89 17

54.0

57.0

HP kW kW kW kW

230

RQYQ12P RQYQ12P 12 33.5 37.5 10.10 10.20 3.32 3.68 26

RQYQ14P RQYQ16P RQYQ14P RQYQ16P 14 16 40.0 45.0 45.0 50.0 11.6 13.6 12.2 13.6 3.45 3.31 3.69 3.68 30 34 1,680x1,240x765 381

284 58.0

60.0 -5~43 -20~15.5 R-410A

9.52 19.1

15.9

12.7 28.6

22.2 150 300 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 3~/50/380-415 25

15

RQYQ18PY1 RQYQ20PY1 RQYQ8P RQYQ10P 18 20 50.4 55.9 56.5 62.5 12.9 15.4 15.1 16.7 3.91 3.63 3.74 39 43 61 62

RQYQ22PY1 RQYQ10P RQYQ12P 22 61.5 69.0 17.8 18.8 3.46 3.67 47

RQYQ24PY1 RQYQ12P

RQYQ26PY1 RQYQ10P

24 67.0 75.0 20.2 20.4 3.32 3.68 52

26 73.0 81.5 21.3 22.2 3.43 3.67 56

35

RQYQ28PY1 RQYQ30PY1 RQYQ32PY1 RQYQ12P RQYQ14P RQYQ16P RQYQ16P 28 30 32 78.5 85.0 90.0 87.5 95.0 100 23.7 25.2 27.2 23.8 25.8 27.2 3.31 3.37 3.31 3.68 60 64 63

15.9

19.1

28.6

34.9 150 300 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 50 60

45 RQYQ34PY1

RQYQ38PY1

RQYQ42PY1 RQYQ10P

34 96.0 108 26.9 29.4 3.57

38 107 119 31.4 32.4 3.41

42 118 132 34.9 35.8 3.38 3.69

Outdoor unit module 1 Outdoor unit module 2

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Current - 50Hz Maximum fuse amps (MFA)

RQYQ10P RQYQ10P 10 28.0 31.5 7.64 8.59 3.66 3.67 21 1,680x930x765

RQYQ36PY1 RQYQ10P RQYQ10P 36 101 113 28.9 30.8 3.49 3.67

RQYQ40PY1 RQYQ12P RQYQ12P 40 112 125 33.8 34.0 3.31 3.68

70

RQYQ44PY1 RQYQ46PY1 RQYQ48PY1 RQYQ12P RQYQ14P RQYQ16P RQYQ16P 44 46 48 124 130 135 138 145 150 35.3 38.8 40.8 36.0 39.4 40.8 3.51 3.35 3.31 3.83 3.68

64 dBA mm mm m m m A

64

65 19.1

34.9

90

(1) Field setting

61

41.3 150 300 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 100

110


RWEYQ-P RWEYQ-PR

SHR =1

High sensible mode

VRV®III water cooled standard & geothermal series

›› First geothermal-sourced VRF system in the world! –– Works with water-glycol temperatures as low as -10°C, making the use of economically sized geothermal collectors possible –– Extremely efficient – COP over 3.4 even with -10°C water temperature, and over 5 with +10°C water temperature ›› Great solution for high-rise buildings – no need to cover big elevation differences with refrigerant piping ›› Unified outdoor unit both for heat pump and heat recovery applications

62


RWEYQ-P RWEYQ-PR

VRV®III water cooled standard & geothermal series

High energy efficiencies results from 2-stage heat recovery VRV®-W benefits from a 2-stage heat recovery facility. The first stage is achieved within the refrigerant system and applies to heat recovery units only. Heat exhausted from indoor units in cooling mode is merely transferred to units in areas requiring heating, maximising energy efficiency and reducing electricity costs.

Heat recovery also available on heat pump units Second stage heat recovery is achieved within the water loop between the water cooled outdoor units. Two-stage heat recovery substantially improves energy efficiency and represents an ideal solution to the requirements of modern office buildings, in which some areas may require cooling even in winter, depending on the degree of sunshine at the time and the number of individuals in the room.

Heat recovery between indoor units

Heat recovery between outdoor units (Heat recovery and heat pump)

All indoor units in cooling mode

Cooling tower (Closed type), boiler

Heat rejected to loop

VRV®-W

VRV®-W Indoor units mainly cooling, partly heating Heat partly rejected to loop

Heat rejected to loop VRV®-W

VRV®-W Full Heat Recovery

Heat rejected to loop VRV®-W VRV®-W Indoor units mainly heating, partly cooling Heat absorbed from loop

Partly heat absorption from loop

VRV®-W VRV®-W All indoor units in heating mode Heat absorption from loop

Heat absorbed from loop

VRV®-W

63


RWEYQ-P RWEYQ-PR

VRV®III water cooled standard & geothermal series

Wide operation range Standard water cooled outdoor units have a wide operation range of between 10°C & 45°C inlet water temperature, both in heating and cooling. For the geothermal series the operation range is extended even more, down to -10°C* in heating and 6°C in cooling mode. * Ethylene glycol should be added to the water when the water inlet temperature is below 5°C STANDARD SERIES • HEAT RECOVERY • HEAT PUMP

GEOTHERMAL SERIES • HEAT RECOVERY • HEAT PUMP

50° 40°

Heating 45°C

Cooling 45°C

Heating 45°C

Cooling 45°C

30° 20° 10°

10°C

10°C 6°C

0° -10°

-10°C

Flexible piping design

Flexible water piping Water cooled VRV® uses water as its heat source, so it is optimal for large buildings, including tall, multi-storey buildings, because the system can tolerate water pressure of up to 1.96 MPa.

Actual piping length between the VRV®-W and indoor units: 120m (Equivalent piping length: 140m)

Furthermore, if the currently installed heat source’s water temperature is between 10°C and 45°C, it may be possible to use the existing water pipe work and heat source. This alone makes it an ideal system solution for building refubishment projects. Because the system is water cooled, outdoor air temperature does not affect its heating capacity. In addition, water cooling means no defrost operation is required, and the resultant rapid start-up time assures quick and comfortable heating, even in cold environment.

Water piping Refrigerant piping

Level difference between indoor units: 15m

VRV®-W

Level difference between the VRV®-W and indoor units: 50m if the VRV®-W is above 40m if the VRV®-W is below

Long refrigerant piping length

VRV®-W

Considerable flexibility is available within the refrigerant circuit since up to 120m actual piping length and 50m* (if the VRV®-W outdoor unit is above the indoor units) in height can exist between the VRV®-W outdoor units and indoor units. Water piping does not intrude on the occupied spaces, so there are no leakage problems.

Indoor installation Water piping length depends on the heat source equipment

* 40m if the VRV®-W outdoor unit is below the indoor units.

64


RWEYQ-P RWEYQ-PR

VRV®III water cooled standard & geothermal series

Heat pump & Heat recovery – standard series Outdoor unit System Capacity range Cooling capacity Heating capacity Power input - 50Hz

Outdoor unit module 1 Nom. Nom. Cooling Heating

Nom. Nom.

EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Inlet water Cooling Min.~Max. temperature Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Discharge gas OD Water Inlet/Outlet Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

HP kW kW kW kW

RWEYQ8P RWEYQ8P 8 22.4 25.0 4.55 4.24 4.89 5.81 17

mm kg dBA dBA °CDB °CWB mm mm mm m m m Hz/V A

RWEYQ10P RWEYQ10P 10 26.7 31.5 6.03 6.05 4.14 5.08 21 1,000x780x550

149

150 -

50

51 10~45 10~45 R-410A 9.52

19.1 (1) 22.2 (1) 15.9 (2) / 19.1 (3) 19.1 (2) / 22.2 (3) PT1 1/4B internal thread/PT1 1/4B internal thread 120 300 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3~/50/380-415 25

(1) In case of heat pump system, gas pipe is not used | (2) In case of heat recovery system | (3) In case of heat pump system

Outdoor unit System

Outdoor unit module 1 Outdoor unit module 2 Outdoor unit module 3

Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Discharge gas OD Current - 50Hz Maximum fuse amps (MFA)

HP kW kW kW kW

dBA mm mm mm A

RWEYQ16P RWEYQ18P RWEYQ20P RWEYQ24P RWEYQ26P RWEYQ28P RWEYQ30P RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P 16 18 20 24 26 28 30 44.8 49.1 53.4 67.2 71.5 75.8 80.1 50.0 56.5 63.0 75.0 81.5 88.0 94.5 9.10 10.6 12.1 13.7 15.1 16.6 18.1 8.48 10.3 12.1 12.7 14.5 16.3 18.2 4.92 4.63 4.41 4.91 4.74 4.57 4.43 5.87 5.48 5.21 5.91 5.62 5.40 5.19 34 36 53 54 55 56 12.7 15.9 19.1 28.6 (1) 34.9 (1) 22.2 (2) / 28.6 (3) 22.2 (2) / 28.6 (3) 22.2 (2) / 28.6 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3) 35 45

(1) In case of heat pump system, gas pipe is not used | (2) In case of heat recovery system | (3) In case of heat pump system

Heat pump & Heat recovery – geothermal series Outdoor unit System Capacity range Cooling capacity Heating capacity Power input - 50Hz

Outdoor unit module 1 Nom. Nom. Cooling Heating

Nom. Nom.

EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Inlet water Cooling Min.~Max. temperature Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Discharge gas OD Water Inlet/Outlet Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)

HP kW kW kW kW

RWEYQ8PR RWEYQ8PY1R 8 22.4 25.0 4.58 4.30 4.89 5.81 17

mm kg dBA dBA °CDB °CWB mm mm mm m m m Hz/V A

RWEYQ10PR RWEYQ10PY1R 10 26.1 31.5 6.30 6.20 4.14 5.08 21 1,000x780x550

149

150 -

50

51 6~45 -10~45 R-410A 9.52

19.1 (1) 22.2 (1) 15.9 (2) / 19.1 (3) 19.1 (2) / 22.2 (3) PT1 1/4B internal thread/PT1 1/4B internal thread 120 300 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3~/50/380-415 25

(1) In case of heat pump system, gas pipe is not used | (2) In case of heat recovery system | (3) In case of heat pump system

65



BSVQ-P8

Individual branch selector for VRV heat recovery

›› Allows individual cool / heat switching for 1 group of indoor units ›› Maximum design flexibility because individual and multi boxes can be combined in one system ›› Low built-in height ›› No drain piping needed ›› Allows multi tenant applications (option PCB required)

Indoor unit Power input

Cooling Nom. Heating Nom. Maximum number of connectable indoor units Maximum capacity index of connectable indoor units Casing Material HeightxWidthxDepth Dimensions Unit Weight Unit Piping Outdoor unit Liquid Type/OD connections Gas Type/OD Discharge gas Type/OD Indoor unit Liquid Type/OD Gas Type/OD Sound absorbing thermal insulation Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

BSVQ100P8

BSVQ160P8 0.005 0.005

kW kW 6 20<x≤100 mm kg mm mm mm mm mm Hz/V A

BSV4/6Q-PV

BSVQ250P8

8 100<x≤160 Galvanised steel plate 207x388x326

160<x≤250

12

15 Brazing connection/9.5 Brazing connection/15.9 Brazing connection/15.9 Brazing connection/22.2 Brazing connection/12.7 Brazing connection/12.7 Brazing connection/19.1 Brazing connection/9.5 Brazing connection/9.5 Brazing connection/15.9 Brazing connection/22.2 Foamed polyurethane, frame resisting needle felt 1~/50/220-240 15

Multi branch selector for VRV heat recovery

›› Faster installation thanks to a reduced number of brazing points and wiring ›› Allows individual cool / heat switching for up to 4/6 groups of indoor units ›› Maximum design flexibility because individual and multi boxes can be combined in one system ›› Low built-in height ›› No drain piping needed Indoor unit Power input

Cooling Nom. kW Heating Nom. kW Maximum number of connectable indoor units Maximum number of connectable indoor units per branch Number of branches Maximum capacity index of connectable indoor units Maximum capacity index of connectable indoor units per branch Casing Material HeightxWidthxDepth mm Dimensions Unit Weight Unit kg Piping Outdoor unit Liquid Type/OD mm connections Gas Type/OD mm Discharge gas Type/OD mm Indoor unit Liquid Type/OD mm Gas Type/OD mm Sound absorbing thermal insulation Power supply Phase/Frequency/Voltage Hz/V Maximum Fuse Amps (MFA) A

BSV4Q100PV 0.020 0.020 24

BSV6Q100PV 0.030 0.030 36 6

4 400

6 600 100 Galvanised steel plate

209x1,053x635 60 Brazing connection/12.7

209x1,577x635 89 Brazing connection/15.9 Brazing connection/28.6

Brazing connection/19.1

Brazing connection/28.6 Brazing connection/9.5 Brazing connection/15.9 Foamed polyurethane, frame resisting needle felt 1~/50/220-240 15

67


INdoor Units As many as 64 separate indoor units can be operated from the single refrigerant circuit of a 54 HP VRV® heat pump

NO LESS THAN 26 DIFFERENT STYLISH AND ELEGANT MODELS IN 116 DIFFERENT VARIANTS — all designed to maximise comfort, minimise operating noise and simplify installation and servicing. system. In fact, the Daikin VRV® indoor unit range, one of the widest on the market, currently comprises

VRV® indoor units are modern, technologically advanced and come in ceiling mounted cassette, concealed ceiling, ceiling suspended, wall mounted and floor standing models. The Roundflow cassette now includes an optional auto cleaning filter, which automatically cleans itself daily, leading to yearly energy savings of up to 10%. Dust from the filter is collected in the unit for removal by simple vacuum cleaning.

Designed to fit rooms of any size and shape, Daikin indoor units are also user friendly, quiet running, ultra reliable, easy to control and supply users with that relaxing ‘extra something’ to the indoor climate.

68



BYCQ140CG

Auto cleaning decoration panel, option for round flow cassette

DAIKIN INTRODUCES FIRST AUTO CLEANING CASSETTE TO EUROPEAN MARKET Daikin launches a new decoration panel for the round flow cassette, equipped with a special filter, which automatically cleans itself once a day. All dust coming from this filter is stored in the indoor unit and can be removed with a normal vacuum cleaner. With this decoration panel energy and maintenance costs will be lower and comfort will be increased

HIGHER EFFICIENCY AND COMFORT FROM DAILY AUTO CLEANING OF THE FILTER ➔ Energy savings up to 50% can be achieved (based on test site in Wolverhampton, UK) With a standard decoration panel the energy consumption of the unit increases slowly because dust accumulates in the filter. After the filter is cleaned the energy consumption is back at the level of installation. With the auto cleaning decoration panel the filter is cleaned everyday and therefore the energy consumption remains constant, resulting in an energy saving exceeding 15% compared to yearly filter cleaning. Depending on local circumstances (e.g. dirty environment), the energy savings can reach up to 50%.

Electricity consumption ratio (%)

160

EASY REMOVAL OF DUST WITH A VACUUM CLEANER WITHOUT OPENING THE UNIT 160

›› ›› ›› ››

130

Accumulation of dirt in the filter causes energy consumption to increase

130

›› ››

100

Dust is stored in dust box Emptying the dust box can be done with a vacuum cleaner No rearrangement of shop interior etc to access the unit Only a vacuum cleaner is required, no ladder or other equipment Qualified personnel is not necessary No manual cleaning – not required to touch the dust

100

Day 1: equal energy consumption After 1 year: > 30% increase in energy consumption => An average increase of 15% in energy consumption on a yearly basis

0

0.5 0

0.5

1 1

1.5 1.5

Operation years

2

LOWER MAINTENANCE COSTS THANKS TO AUTO CLEANING FUNCTION

2

Filter is never cleaned Filter is cleaned once a year Filter is cleaned every day

›› ››

70

Less time needed for filter maintenance Less qualified personnel required


FXFQ-P9

Round flow cassette

›› Round-flow discharge –– 360° out-blow of air, unique in the industry ›› Choice of three decoration panels –– Standard panel with grey discharge –– Standard panel with white discharge –– Auto-cleaning panel – unique in the industry ›› Low noise –– 28 dB(A) on low fan speed till size 63 ›› Very low installation height –– 214 mm for units up to size 63 ›› Well equipped: –– Drain pump standard (850 mm lift from ceiling level) –– Fresh air intake (either direct or with kit)

FLEXIBLE AIR-FLOW CONFIGURATION Round flow

4-Way blow

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. HeightxWidthxDepth Dimensions Unit Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Sound power level Cooling Nom. Sound pressure Cooling High/Low level Heating High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm kg

mm kg m³/min m³/min dBA dBA dBA mm Hz/V A

3-Way blow

FXFQ20P9 2.2 2.5

FXFQ25P9 2.8 3.2 0.053 0.045

2-Way blow

FXFQ32P9 3.6 4.0

FXFQ40P9 4.5 5.0 0.063 0.055 204x840x840

FXFQ80P9 FXFQ100P9 FXFQ125P9 9.0 11.2 14.0 10.0 12.5 16.0 0.120 0.173 0.258 0.108 0.176 0.246 246x840x840 288x840x840 20 21 24 26 BYCQ140CW1 / BYCQ140CW1W / BYCQ140CGW1 Pure White(RAL 9010) 50x950x950 / 50x950x950 / 130x950x950 5.5 / 5.5 / 11.5 12.5/9.0 13.5/9.0 15.5/10.0 16.5/11.0 23.5/14.5 26.5/17.0 33.0/20.0 12.5/9.0 13.5/9.0 15.0/9.5 17.5/12.0 23.5/14.5 28.0/17.5 33.0/20.0 49 50 51 52 55 58 61 31/28 32/28 33/28 34/29 38/32 41/33 44/34 31/28 32/28 33/28 36/30 38/32 42/34 44/34 R-410A 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25) 1~/50/60/220-240/220 16

71

FXFQ50P9 5.6 6.3 0.083 0.067

FXFQ63P9 7.1 8.0 0.095 0.114


FXZQ-M9

4-way blow ceiling mounted cassette

›› Ideal for small offices –– Available in class 15 capacity size ›› Compact casing –– Fits in standard European ceiling tiles ›› Uniform outlook –– Same decoration panel for all unit sizes ›› Low noise –– < 26 dB(A) on low fan speed till size 32 ›› Easy service –– Access to electrical box through suction grille ›› Well equipped: –– Drain pump standard (750 mm lift from ceiling level) –– Fresh air intake (direct, connection flange available as accessory kit)

FLEXIBLE AIR-FLOW CONFIGURATION 4-Way blow

3-Way blow

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling High/Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW

2-Way blow

FXZQ15M9 1.7 1.9 0.073 0.064

FXZQ20M9 2.2 2.5

FXZQ25M9 2.8 3.2 0.073 0.064

mm kg BYFQ60BW1 mm kg m³/min dBA dBA mm Hz/V A

8.1/7 -/46 29/25

9.0/7.0 -/47 30/25

6.35/12.7/VP20 (I.D. 20/O.D. 26)

72

FXZQ32M9 3.6 4.0 0.076 0.068

Unpainted 286x575x575 18 BYFQ60B7W1 White 55x700x700 2.7 9.5/7.5 -/49 32/26 R-410A 6.35/12.70/26 1~/50/220-240 15

FXZQ40M9 4.5 5.0 0.089 0.080

FXZQ50M9 5.6 6.3 0.115 0.107

11.0/8.0 -/53 36/28

14.0/10.0 -/58 41/33


FXCQ-M8

2-way blow ceiling mounted cassette

›› Easy service –– Access to electrical box through suction grille –– Easy cleaning thanks to completely flat suction panel and removable swing flaps ›› Comfort and convenience functions –– Ceiling soiling prevention –– Draft prevention ›› Well equipped: –– Drain pump standard (600 mm lift from ceiling level) –– Fresh air intake –– Branch duct connection possibility

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Required ceiling void > Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Sound power level Cooling Nom. Sound pressure Cooling High/Low level Heating High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW

FXCQ20M8 2.2 2.5 0.077 0.044

FXCQ25M8 2.8 3.2

FXCQ32M8 3.6 4.0

FXCQ40M8 4.5 5.0

0.092 0.059

FXCQ50M8 5.6 6.3 0.130 0.097

FXCQ63M8 7.1 8.0 0.161 0.126

305x995x600

305x1,180x600

Unpainted mm mm kg

305x780x600 350 26 BYBC32GJW1

31

32 BYBC50GJW1

35 BYBC63GJW1

White (10Y9/0.5) mm kg m³/min m³/min dBA dBA dBA

53x1,030x680 8 7/5 7/5 45 33/28 33/28

53x1,245x680 8.5 12/9 12/9

9/6.5 9/6.5 50 35/29 35/29

35.0/29.0 35.0/29.0 R-410A 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 1~/50/230 16

mm Hz/V A

73

35.5/30.5 35.5/30.5

53x1,430x680 9.5 16.5/13 16.5/13 52 38/33 38/33 9.52/15.90/VP25 (O.D. 32 / I.D. 25)


FXKQ-MA

Ceiling mounted corner cassette

›› Extremely slim for small ceiling spaces –– Installation height of only 220 mm ›› Versatile application –– Possibility to discharge into a duct –– Can work from ceilings up to 3.8 m high –– Suitable for technical room cooling ›› Easy service –– Access to electrical box through suction grille ›› Well equipped: –– Drain pump standard (500 mm lift from ceiling level) –– Fresh air intake –– Branch duct connection possibility

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. HeightxWidthxDepth Dimensions Unit Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm kg

FXKQ25MA 2.8 3.2

FXKQ32MA 3.6 4.0

FXKQ40MA 4.5 5.0 0.076 0.056

0.066 0.046 215x1,110x710 31 BYK45FJW1

FXKQ63MA 7.10 8.00 0.105 0.085 215x1,310x710 34 BYK71FJW1

White mm kg m³/min dBA dBA mm Hz/V A

70x1,240x800 8.5 11/9

13/10

70x1,440x800 9.5 18/15

40.0/34.0

42.0/37.0

38.0/33.0 R-410A 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 1~/50/60/220-240/220 15

74

9.52/15.9/VP25 (O.D. 32 / I.D. 25)


FXUQ-MA

4-way blow ceiling suspended unit

›› Unique in the industry –– 4-way air distribution without needing a false ceiling – only by Daikin ›› Powerful –– Suitable for ceilings up to 3.8 m high ›› Ideal unit for refurbishment projects –– Requires no false ceiling –– Saves wall space ›› Suitable for technical room cooling ›› Drain pump standard (350 mm lift from ceiling level)

FLEXIBLE AIR-FLOW CONFIGURATION 4-Way blow

3-Way blow

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Sound power level Cooling High/Nom. Sound pressure Cooling High/Low level Heating High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage

Indoor unit Power input Casing Dimensions Weight Piping connections

Cooling Heating Material Unit Unit Outdoor unit Indoor unit

Nom. Nom.

kW kW kW kW

2-Way blow

FXUQ71MA 8.0 9.0 0.180 0.160

FXUQ100MA 11.2 12.5 0.289 0.269 White

mm kg m³/min m³/min dBA dBA dBA

165x895x895 25 19/14 19/14 56/40/35 40/35

230x895x895 31 29/21 29/21 59/43/38 43/38 R-410A 9.52/15.9/I.D. 20/O.D. 26 1~/50/220-240

mm Hz/V

kW kW

BEVQ71MA 0.189 0.169

BEVQ125MA 0.298 0.278

Galvanised steel plate 100x350x225

mm kg Type/OD mm OD/Type Type/OD mm Type/OD mm

Sound absorbing thermal insulation Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

32/23 32/23 60/44/39 44/39

BEVQ100MA

HeightxWidthxDepth Liquid Gas Liquid Gas

FXUQ125MA 14.0 14.0

3.0 Flare connection/9.52 15.9/Flare connection Flare connection/9.52 Flare connection/15.9 Flame and heat resistant foamed polyetherene 1~/50/60/220-240/220 15

Hz/V A

75

3.5


FXHQ-MA

Ceiling suspended unit

›› Powerful and effective –– Wide 100° air discharge –– Suitable for ceilings up to 3.5 m high ›› Easy maintenance –– Electrical box and fan motors can be accessed via the suction opening ›› Ideal unit for refurbishment projects –– Requires no false ceiling –– Saves wall space ›› Suitable for technical room cooling ›› Integrated drain pump available as option (540 mm lift from unit’s top)

POWERFUL AND EFFECTIVE

Coanda effect

100°

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm kg m³/min dBA dBA mm Hz/V A

FXHQ32MA 3.6 4.0 0.111 0.111 195x960x680 24 12/10 36/31 6.35/12.7/VP20 (I.D. 20/O.D. 26)

76

FXHQ63MA FXHQ100MA 7.1 11.2 8.0 12.5 0.115 0.135 0.115 0.135 White (10Y9/0.5) 195x1,160x680 195x1,400x680 28 33 17.5/14 25/19.5 39/34 45/37 R-410A 9.52/15.9/VP20 (I.D. 20/O.D. 26) 1~/50/60/220-240/220 15


FXAQ-P

Wall mounted unit

›› Ideal for small offices or rooms –– Class 15 capacity size coming in 2nd half of 2012 ›› Stylish design in line with Daikin residential range ›› Easy maintenance –– Flat front panel and swing flap can be easily removed and washed –– All service work can be carried out from the front of the unit without taking it off the wall ›› Ideal unit for refurbishment projects –– Requires no false ceiling

NEW Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm kg m³/min dBA dBA mm Hz/V A

*FXAQ15P 1.7 1.9 290x795x238 7/4.5 33/29 R-410A -/-/ 1~/50/220-240 -

FXAQ20P 2.2 2.5 0.019 0.029

FXAQ25P 2.8 3.2 0.028 0.034

7.5/4.5

290x795x238 11 8/5

FXAQ32P FXAQ40P 3.6 4.5 4.0 5.0 0.030 0.020 0.035 0.020 White (3.0Y8.5/0.5)

8.5/5.5

12/9

FXAQ50P 5.6 6.3 0.033 0.039

FXAQ63P 7.1 8.0 0.050 0.060

290x1,050x238 14 15/12

19/14

42.0/36.0

46.0/39.0

35.0/29.0

77

36.0/29.0

37.0/29.0

39.0/34.0 R-410A 6.35/12.7/VP13 (I.D. 13/O.D. 18) 1~/50/220-240 16

*Note: grey cells contain preliminary data


FXDQ-M9

Small concealed ceiling unit

›› Designed for hotel rooms: –– Very compact to fit in the ceiling of the entrance corridor –– 230 x 502 x 652 mm (HxWxD) ›› Versatile installation –– Suction from back or from bottom –– Choice of drain outlet side –– Air filter standard

VERSATILE INSTALLATION

Air suction direction Drain pan

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Required ceiling void > Weight Unit Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Sound power level Cooling Nom. Sound pressure Cooling High/Low level Heating High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm mm kg m³/min m³/min dBA dBA dBA

FXDQ20M9 2.2 2.5

FXDQ25M9 2.8 3.2 0.050 0.050 Unpainted 230x502x652 250 17

6.7/5.2 6.7/5.2

7.4/5.8 7.4/5.8 50 37/32 37/32 R-410A 6.35/12.7/I.D. 21.6, O.D. 27.2 1~/50/230 16

mm Hz/V A

78


FXDQ-P7

Slim concealed ceiling unit

›› Ideal for small offices or hotel rooms –– Available in class 15 capacity size ›› Extremely slim for small ceiling spaces –– Unit height of only 200 mm ›› Improved user comfort –– 3 fan speeds can be selected ›› Versatile installation –– Suction from back or from bottom –– ESP for moderate ducting (>30 Pa) –– Air filter standard ›› Drain pump standard (550mm lift from unit’s top)

VERSATILE INSTALLATION

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Required ceiling void > Weight Unit Fan-Air flow rate - 50Hz Cooling Super high/High/Nom./Low Fan-External static pressure - 50Hz High/Nom. Sound power level Cooling Nom. Sound pressure level Cooling High/Nom./Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm mm kg m³/min Pa dBA dBA mm Hz/V A

FXDQ15P7 1.7 1.9

FXDQ20P7 2.2 2.5 0.086 0.067

FXDQ25P7 2.8 3.2

FXDQ32P7 3.6 4.0 0.089 0.070 Unpainted

FXDQ40P7 4.5 5.0 0.160 0.147

200x700x620

FXDQ50P7 5.6 6.3 0.165 0.152

200x900x620

FXDQ63P7 7.1 8.0 0.181 0.168 200x1,100x620

240 23 7.5/7.0/-/6.4

8.0/7.2/-/6.4

27 10.5/9.5/-/8.5

51 33/31/29

52 34/32/30

30/10 50 32/31/29

R-410A 6.35/12.7/VP20 (I.D. 20/O.D. 26) 1~/50/60/220-240/220 15

/50/60/220-240/220 16

79

28 12.5/11.0/-/10.0 44/15 53 35/33/31

31 16.5/14.5/-/13.0 54 36/34/32 9.52/15.9/VP20 (I.D. 20/O.D. 26)


FXSQ-P FXMQ-P7

Concealed ceiling unit with inverter driven fan

›› DC Inverter Fans – unique technology for unique features –– Automatic air flow adjustment (see below) for easy commissioning –– Finely selectable ESP – from 10 to 15 fan curves available on every unit –– ESP (fan curves) selectable via remote controller – no need to open a service access –– 3 fan speeds selectable by end-user –– Up to 20% lower power consumption compared to units with AC fans ›› Wide capacity range - from 2.2 to 16.0 kW cooling capacity ›› Versatile installation –– Suction from back or from bottom –– ESP for long ducting (70 ~ 200 Pa) –– Air filter standard ›› Well equipped: –– Drain pump standard (625mm lift from unit’s top for FXSQ, 700mm for FXMQ) –– Fresh air intake Test running

VERSATILE INSTALLATION Design

ዘDuct reconstruction ዘChanging motor ዘ

New flow Test running

Test running

ዘDuct reconstruction ዘChanging motor ዘ

Design New flow Test running

Easy installation thanks to automatic air flow adjustment towards nominal air flow: Installation made easier ››

›› ›› ››

After installation, it is possible that the actual duct resistance is lower or higher than expected at time of designing. As a consequence the air flow will be too high or too low. (Example on right shows case with lower duct resistance) Too low air flow can lead to insufficient capacity and reliability problems; too high air flow can lead to discomfort and noise issues With the automatic air flow adjustment function the unit adapts its fan speed automatically in order to reach the nominal air flow (within 10%) Alternatively the installer can manually select a fan curve with the wired remote control. +/- 10%

External static pressure (Pa)

Reduced installation time

Fan characteristic curve Actual duct resistance curve Duct resistance curve at the time of designing Rated air flow Airflow without air flow automatic adjustment Actual airflow

Air flow (m³/min)

80

+/- 10%


FXSQ-P FXMQ-P7

FXSQ-P - Medium static pressure Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Required ceiling void > Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Fan-External static pressure - 50Hz High/Nom. Sound power level Cooling Nom. Sound pressure Cooling High/Low level Heating High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm mm kg

mm kg m続/min m続/min Pa dBA dBA dBA mm Hz/V A

FXSQ20P FXSQ25P 2.2 2.8 2.5 3.2 0.041 0.029

FXSQ32P 3.6 4.0 0.044 0.032

FXSQ40P FXSQ50P FXSQ63P FXSQ80P FXSQ100P FXSQ125P FXSQ140P 4.5 5.6 7.1 9.0 11.2 14.0 16.0 5.0 6.3 8.0 10.0 12.5 16.0 18.0 0.097 0.074 0.118 0.117 0.185 0.261 0.085 0.062 0.106 0.105 0.173 0.249 Unpainted 300x550x700 300x700x700 300x1,000x700 300x1,400x700 350 23 26 35 46 47 BYBS32DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 White (10Y9/0.5) 55x650x500 55x800x500 55x1,100x500 55x1,500x500 3.0 3.5 4.5 6.5 9/6.5 9.5/7 16/11 19.5/16 25/20 32/23 39/28 46/32 9/6.5 9.5/7 16/11 19.5/16 25/20 32/23 39/28 46/32 70/30 100/30 100/40 120/40 120/50 140/50 55 56 63 59 63 61 66 67 32/26 33/27 37/29 37/30 38/32 40/33 42/34 32/26 33/27 37/29 37/30 38/32 40/33 42/34 R-410A 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25) 1~/50/60/220-240/220 16

FXMQ-P7 - High stactic pressure Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Required ceiling void > Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Fan-External static pressure - 50Hz High/Nom. Sound power level Cooling High/Nom. Sound pressure Cooling High/Nom./Low level Heating High/Nom./Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm mm kg

mm kg m続/min m続/min Pa dBA dBA dBA mm Hz/V A

FXMQ20P7 FXMQ25P7 2.2 2.8 2.5 3.2 0.049 0.037

FXMQ32P7 3.6 4.0 0.053 0.041

300x550x700

FXMQ40P7 4.5 5.0 0.151 0.139

FXMQ50P7 5.6 6.3 0.110 0.098 Unpainted

300x700x700

FXMQ63P7 7.1 8.0 0.120 0.108 300x1,000x700

FXMQ80P7 9.0 10.0 0.171 0.159

FXMQ100P7 11.2 12.5 0.176 0.164

FXMQ125P7 14.0 16.0 0.241 0.229

300x1,400x700

350 23 BYBS32DJW1

26 35 46 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 White (10Y9/0.5) 55x650x500 55x800x500 55x1,100x500 55x1,500x500 3.0 3.5 4.5 6.5 9/6.5 9.5/7 16/11 18/15 19.5/16 25/20 32/23 39/28 9.0/6.5 9.5/7 16/11 18/15 19.5/16 25/20 32/23 39/28 100/50 160/100 200/100 56/57/65/61/64/67/65/70/33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 R-410A 6.35/12.7/VP25 (I.D. 25/O.D. 32) 9.52/15.9/VP25 (I.D. 25/O.D. 32) 1~/50/60/220-240/220 16

81


FXMQ-MA

Large concealed ceiling unit

›› Powerful units –– ESP up to 270 at nominal air flow –– Nominal air flow up to 4.320 m3/h –– Cooling capacity up to 28 kW –– Heating capacity up to 31.5 kW ›› Intended for central technical room installation

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate - 50Hz Cooling High/Low Fan-External static pressure - 50Hz High/Nom. Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm kg m³/min Pa dBA dBA mm Hz/V A

FXMQ200MA 22.4 25.0 1.294 1.294

FXMQ250MA 28.0 31.5 1.465 1.465 470x1,380x1,100 137

58/50 221/132

72/62 270/191 48/45 R-410A

9.52/19.1/PS1B

9.52/22.2/PS1B 1~/50/60/220-240/220 15

82


FXNQ-P

Concealed floor standing unit

›› Compact –– Only 22 cm deep and 61 cm high ›› Flexible installation –– Floor standing –– Wall mounted (feet can be removed) ›› Ideal for installation within a windowsill ›› The connecting port faces downward, eliminating the need to attach auxiliary piping

Connecting port

Refrigerant piping

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm kg m³/min dBA dBA

FXNQ20P 2.2 2.5

FXNQ25P 2.8 3.2

0.049 0.049 610x930x220 19 7/6

FXNQ32P 3.6 4.0

FXNQ40P 4.5 5.0

FXNQ50P 5.6 6.3

0.090 0.090 610x1,070x220 23 8/6

FXNQ63P 7.1 8.0

0.110 0.110 610x1,350x220 27 11/8.5

14/11

16/12

38/33

39/34

40/35

35/32 R-410A

mm Hz/V A

6.35/12.7/ 1~/50/60/220-240/220 15

83

9.52/15.9/


FXLQ-P

Floor standing unit

›› New stylish design –– Pure white (RAL9010) finish ›› Flexible installation –– Floor standing by wall –– Wall mounted (feet can be removed) –– Free standing (with optional back panel) ›› Remote controller can be easily integrated in the unit

FLEXIBLE INSTALLATION

Optional back panel

Removable feet for wall installation

Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW mm kg m³/min dBA dBA

FXLQ20P 2.2 2.5

FXLQ25P 2.8 3.2 0.049 0.049

600x1,000x232 27 7/6 35/32

mm Hz/V A

84

FXLQ32P 3.6 4.0

FXLQ40P 4.5 5.0

0.090 0.090 Fresh white (RAL9010) / Dark grey (RAL7011) 600x1,140x232 32 8/6 11/8.5 38/33 R-410A 6.35/12.7/ 1~/50/60/220-240/220 15

FXLQ50P 5.6 6.3

FXLQ63P 7.1 8.000 0.110 0.110

600x1,420x232 38 14/11

16/12

39/34

40/35 9.52/15.9/


HXHD-A

Heating only hydrobox for VRV

›› Hot water production up to 80°C without electrical heaters – completely heat pump based ›› Leaving water temperature control from 25°C to 80°C, with weather-dependent set-point possible ›› Plug&Play thanks to integrated hydronics –– Variable speed water pump (inverter) –– Expansion vessel –– Safety and air purge valves –– And all other required elements ›› Only for REYAQ-P heat recovery systems, no BSVQ box necessary for connecting to the system ›› Wide range of options –– Hot water tanks –– Solar collector solutions 45°C - 75°C

Liquid pipe Gas pipe Discharge gas pipe F1, F2 communication Hot water

Domestic hot water VRV indoor units

25°C - 75°C Air handling unit

Domestic hot water tank

BS-Box

45°C - 75°C Low temp. radiator BS-Box Heating only hydrobox for VRV

VRV heat recovery with connection to heating only hydrobox (REYAQ10-16P)

25°C - 35°C

Under floor heating

Indoor unit Heating capacity Casing

Nom. Colour Material HeightxWidthxDepth Dimensions Unit Weight Unit Sound pressure Nom. level Night quiet mode Level 1 Operation range Heating Ambient Min.~Max. Water side Min.~Max. Domestic hot Ambient Min.~Max. water Water side Min.~Max. Refrigerant Type Refrigerant circuit Gas side diameter Liquid side diameter Water circuit Piping connections diameter Heating water system Water volume Min.~Max. Power supply Phase/Frequency/Voltage Current Recommended fuses

HXHD125A 14.0 Metallic grey Precoated sheet metal 705x600x695 92 42 (1) / 43 (2) 38 (5) -20~20 / 24 (3) 25~80 -20~43 45~75 R-134a 12.7 9.52 G 1” (female) 20~200 1~/50/220-240 20

kW

mm kg dBA dBA °C °C °CDB °C mm mm inch l Hz/V A

(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting

85


EKHTS-AC

Domestic hot water tank

›› Stainless steel domestic hot water tank ›› The indoor unit and domestic hot water tank can be stacked to save space, or installed next to each other, if only limited height is available ›› Available in 200 and 260 liters ›› Heat loss is reduced to a minimum thanks to the high quality insulation ›› At necessary intervals, the indoor unit can heat up the water to 60°C to prevent the risk of bacteria growth ›› Efficient temperature heat-up: from 10°C to 50°C in only 60 minutes

Indoor unit Casing Dimensions Weight Tank

Heat exchanger

EKHTS200AC

Colour Material HeightxWidthxDepth Unit Unit Empty Water volume Material Maximum water temperature Quantity Tube material Face area Internal coil volume

mm kg l °C

m² l

EKHTS260AC Metallic grey Galvanised steel (precoated sheet metal) 2,010x600x695 (Integrated on indoor unit) 2,285x600x695 (Integrated on indoor unit) 70 78 200 260 Stainless steel (EN 1.4521) 75 1 Duplex steel (EN 1.4162) 1.56 7.5

Domestic hot water tank with possibility for solar connection

EKHWP-A

›› Tank designed for connection with thermal solar collectors ›› Available in 300 and 500 liters ›› Large hot water storage tank to provide domestic hot water at any time ›› Heat loss is reduced to a minimum thanks to the high quality insulation ›› Space heating support possible (500l tank only)

Indoor unit Casing Dimensions Weight Tank Heat exchanger

EKHWP300A Colour Material HeightxWidthxDepth Unit Unit Empty Water volume Maximum water temperature Domestic hot Tube material water Face area Internal coil volume Operating pressure Average specifc thermal output Charging Tube material Face area Internal coil volume Average specifc thermal output Auxiliary solar Tube material heating Face area Internal coil volume Average specifc thermal output

EKHWP500A Dust grey (RAL7037) Impact resistant polypropylene

mm kg l °C

1,590x595x615 59 300

m² l bar W/K

5.7 27.8

1,590x790x790 92 500 85 Stainless steel (DIN 1.4404) 5.9 28.4 6

2,795

2,860 Stainless steel (DIN 1.4404)

m² l W/K

2.5 12.3 1,235

m² l W/K

-

3.7 17.4 1,809 Stainless steel (DIN 1.4404)

86

1.0 5 313


EKSRPS

Pump station

›› Save energy and reduce CO2 emissions with a solar system for domestic hot water production ›› Pump station connectable to unpressurised solar system ›› Pump station and control provide the transfer of solar heat to the domestic hot water tank

Indoor unit Mounting HeightxWidthxDepth Dimensions Unit Thermal performance Zero loss collector efficiency η0 Control Type Power consumption Sensor Solar panel temperature sensor Storage tank sensor Return flow sensor Feed temperature and flow sensor Power supply Voltage

EKSRPS3 On side of tank 815x230x142 Digital temperature difference controller with plain text display 2 Pt1000 PTC PTC Voltage signal (3.5V DC) 230

mm % W

V

EKSV/H-P

Solar collector

›› Horizontal and vertical solar collector for domestic hot water production ›› Solar panels can produce up to 70% of the energy needed for hot water production – a major cost saving ›› High efficiency collectors transfer all the short-wave solar radiation into heat as a result of their highly selective coating ›› Easy to install on roof tiles ›› The solar collectors are charged with water only when needed for heating – avoiding the need for ‘anti-freeze’ protection Indoor unit Dimensions Weight Volume Surface

Coating Absorber Glazing Allowed roof angle Operating pressure Stand still temperature Thermal performance

Installed position

Unit Unit

HeightxWidthxDepth

Outer Aperture Absorber

Min.~Max. Max. Max. Zero loss collector efficiency η0 Heat loss coefficient a1 Temperature dependence of the heat loss coefficient a2 Thermal capacity Incident angle modifier AM at 50°

mm kg l m² m² m²

° bar °C % W/m².K W/m².K² kJ/K

EKSV26P 2,000x1,300x85

EKSH26P 1,300x2,000x85 43

1.7

2.1 2.601 2.364 2.354 Micro-therm (absorption max.96%, Emission ca. 5% +/-2%) Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate Single pane safety glass, transmission +/- 92% 15~80 6 200 78.7 4.270 0.0070 6.5 0.94 Vertical Horizontal

87



VAM-FA

Heat reclaim ventilation

Clean outdoor air Total heat exchanged foul air

Foul indoor air

Total heat exchanged clean air

›› Energy saving ventilation by recovery of indoor unit heat/cold ›› Free cooling when outdoor temperature is below indoor temperature (eg. during night time) ›› Wide range of units: air flow rate from 150 up to 2,000 m³/h ›› Specially developed heat exchange element with High Efficiency Paper (HEP) ›› No drain piping needed ›› Can operate in over- and under pressure

High Efficiency Paper Outdoor

Indoor

30.6°C 62% RH

RH: Relative Humidity SA: Supply Air (to room) RA: Return Air (from room)

SA 27.4°C 63% RH Temperature and humidity RA 26°C 50% RH

32°C 70% RH

SA Integrallyformed liner RA

Integrally-formed liner

Ventilation Ultra high Power input - 50Hz Heat exchange mode Nom. Ultra high Bypass mode Nom. Temperature exchange efficieny - 50Hz Ultra high Enthalpy exchange Cooling Ultra high efficieny - 50Hz Heating Ultra high Operation mode Heat exchange system Heat exchange element HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate Heat exchange mode Ultra high - 50Hz Bypass mode Ultra high Fan-External static pressure - 50Hz Ultra high Heat exchange mode Ultra high Sound pressure level - 50Hz Bypass mode Ultra high Operation range Min. Max. Relative humidity Connection duct diameter Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW % % %

mm kg m³/h m³/h Pa dBA dBA °CDB °CDB % mm Hz/V A

VAM150FA 0.116 0.116 74

VAM250FA 0.141 0.141 72

VAM350FA VAM500FA VAM650FA VAM800FA VAM1000FA VAM1500FA VAM2000FA 0.194 0.212 0.380 0.451 0.469 0.864 0.953 0.194 0.212 0.380 0.451 0.469 0.864 0.953 75 74 75 58 61 58 60 61 64 65 62 63 65 66 Heat exchange mode / Bypass mode / Fresh-up mode Air to air cross flow total heat (sensible + latent heat) exchange Specially processed non-flammable paper 364x1,004x1,156 726x1,514x868 726x1,514x1,156 285x776x525 301x828x816 364x1,004x868 24 33 48 61 132 158 150 250 350 500 650 800 1,000 1,500 2,000 150 250 350 500 650 800 1,000 1,500 2,000 69 64 98 93 137 157 137 27 / 28.5 28 / 29 32 / 34 33 / 34.5 34.5 / 35.5 36 / 37 36 / 37 39.5 / 41.5 40 / 42.5 27 / 28.5 28 / 29 32 / 34 33.5 / 34.5 34.5 / 35.5 36 / 37 36 / 37 40.5 / 41.5 40 / 42.5 -15 50 80% or less 100 150 200 250 350 1~/50/60/220-240/220 15

89


VKM-G(M)

›› ›› ›› ›› ›› ››

Heat reclaim ventilation, humidification and air processing

Creates a high quality indoor environment by pre conditioning incoming fresh air Humidification of incoming air maintains a comfortable indoor humidity level, even during heating Energy saving ventilation by recovery of indoor unit heat/cold Free cooling when outdoor temperature is below indoor temperature (eg. during night time) Specially developed heat exchange element with High Efficiency Paper (HEP) Can operate in over- and under pressure

Ventilation & DX coil Ultra high Power input - 50Hz Heat exchange mode Nom. Ultra high Bypass mode Nom. Fresh air Cooling conditioning load Heating Temperature exchange efficiency - 50Hz Ultra high Enthalpy exchange efficiency - 50Hz Cooling Ultra high Operation mode Heat exchange system Heat exchange element HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate Heat exchange mode Ultra high - 50Hz Bypass mode Ultra high Fan-External static pressure - 50Hz Ultra high Heat exchange mode Ultra high Sound pressure level - 50Hz Bypass mode Ultra high Operation range Around unit Supply air Return air Connection duct diameter Piping Liquid OD connections Gas OD Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA) Ventilation, DX coil & humidification Ultra high Power input - 50Hz Heat exchange mode Nom. Ultra high Bypass mode Nom. Fresh air Cooling conditioning load Heating Temperature exchange efficiency - 50Hz Ultra high Enthalpy exchange efficiency - 50Hz Cooling Ultra high Operation mode Heat exchange system Heat exchange element Humidifier System HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate Heat exchange mode Ultra high - 50Hz Bypass mode Ultra high Fan-External static pressure - 50Hz Ultra high Heat exchange mode Ultra high Sound pressure level - 50Hz Bypass mode Ultra high Operation range Around unit Supply air Return air Connection duct diameter Piping Liquid OD connections Gas OD Water supply Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)

kW kW kW kW % %

mm kg m³/h m³/h Pa dBA dBA °CDB °CDB °CDB mm mm mm

VKM50G 0.560 0.560 4.71 5.58 76 64

VKM80G 0.620 0.620 7.46 8.79 78 66 Heat exchange mode / Bypass mode / Fresh-up mode Air to air cross flow total heat (sensible + latent heat) exchange Specially processed non-flammable paper 387x1,764x1,214 109 750 750 170 40 / 41 / 41.5 40 / 41 / 41.5 0°C~40°CDB, 80% RH or less -15°C~40°CDB, 80% RH or less 0°C~40°CDB, 80% RH or less 250 6.35 12.7 PT3/4 external thread 1~/50/220-240 15

387x1,764x832 96 500 500 180 38 / 38.5 / 39 38 / 38.5 / 39

200

Hz/V A

kW kW kW kW % %

mm kg m³/h m³/h Pa dBA dBA °CDB °CDB °CDB mm mm mm mm

VKM50GM 0.560 0.560 4.71 5.58 76 64

VKM80GM 0.620 0.620 7.46 8.79 78 66 Heat exchange mode / Bypass mode / Fresh-up mode Air to air cross flow total heat (sensible + latent heat) exchange Specially processed non-flammable paper Natural evaporating type 387x1,764x1,214 120 750 750 140 38.5 / 39 / 40 38.5 / 39 / 40 0°C~40°CDB, 80% RH or less -15°C~40°CDB, 80% RH or less 0°C~40°CDB, 80% RH or less 250 6.35 12.7 6.4 PT3/4 external thread 1~/50/220-240 15

387x1,764x832 102 500 500 160 37 / 37.5 / 38 37 / 37.5 / 38

200

Hz/V A

90

VKM100G 0.670 0.670 9.12 10.69 74 62

114 950 950 150 40 / 40.5 / 41 40 / 40.5 / 41

VKM100GM 0.670 0.670 9.12 10.69 74 62

125 950 950 110 39 / 39.5 / 40 39 / 39.5 / 40


FXMQ-MF

Outdoor air processing unit, ventilation and air processing

›› 100% fresh air intake possible ›› Ideal solution for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings ›› Operation range: -5°C to 43°C ›› Up to 225Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas

Ventilation & air processing Cooling capacity Nom. Heating capacity Nom. Power Input Cooling Nominal (50Hz) Heating Nominal HeightxWidthxDepth Dimensions Unit Weight Unit Air Flow Rate Cooling Heating External Static Pressure Standard Refrigerant Type Sound Power Cooling Nominal Nominal (220V) Sound Pressure Cooling Piping Liquid OD connections Gas OD Drain Power supply Phase / Frequency / Voltage

kW kW kW kW mm kg m3/min m3/min Pa dBA dBA mm mm

FXMQ125MF 14.0 8.9 0.359 0.359 470x744x1,100 86 18

FXMQ200MF 22.4 13.9 0.548 0.548

FXMQ250MF 28.0 17.4 0.638 0.638 470x1,380x1,100 123

28 225 R-410A -

185

42

35 205

47 9.52 19.1 PS1B 1~ / 50 / 220-240

15.9

Hz / V

91

22.2


EKEQMCB VRV® air handling applications

›› Integrated air conditioning and air handling solution from one supplier! ›› Connect any Air Handling Unit to any VRV®! –– Even geothermal-sourced VRV® WIII possible! EKEXV-kit

›› Efficiency of DX system both for cooling and for heating! ›› Unique application for Daikin VRV® III Heat Recovery with continuous heating during defrost!

EKEQMCB

gas pipe liquid pipe F1-F2 other communication

CONTROL BOXES

EKEQMCB

Control type Control options

Daikin control Room temperature control [via Remote Controller (accessory) or via External room temperature sensor (accessory)] Return air temperature control (via a supplied thermistor) Setpoint 16 ~ 32°C via Daikin Remote Controller (accessory) On / Off potential free input Fan Control potential free output (e.g. to stop AHU during defrost) Operation / Error output possible by accessory (KRP4A51)

Regulation range Inputs & Outputs

Daikin Remote Controller Dimensions

BRC1D52 BRC1E51A Height Width Depth

Weight Power supply

Expansion Valve Kits Allowed heat Cooling exchanger (evaporation capacity temp. 6°C) Heating (condensing temp. 46°C) Dimensions Weight Sound pressure level Operation range

Unit Unit Nom. Cooling Heating Operation range - Cooling on coil temperature Heating Refrigerant Type Piping Liquid connections Gas 1 2

Required for end-user control (order separatelly) 132 400 200 3.6 1~ / 230V / 50Hz

mm mm mm kg

Minimum Standard Maximum Minimum Standard Maximum HeightxWidthxDepth

Min./Max. Min./Max. Max. Min.

kW kW kW kW kW kW mm kg dBA °CDB °CWB °CDB °CDB

OD OD

mm mm

EKEXV50 5.0 5.6 6.2 5.6 6.3 7.0

EKEXV63 6.3 7.1 7.8 7.1 8.0 8.8

EKEXV80 7.9 9.0 9.9 8.9 10.0 11.1

6.35 6.35

45% relative humidity The temperature of the air entering the coil in heating mode can be reduced to -5°CDB. Contact your local dealer for more information

92

EKEXV100 EKEXV125 10.0 12.4 11.2 14.0 12.3 15.4 11.2 13.9 12.5 16.0 13.8 17.3 401x215x78 2.9 45 -5.0/46.0 -/351 102 R-410A 9.52 9.52

EKEXV140 15.5 16.0 17.6 17.4 18.0 19.8

EKEXV200 17.7 22.4 24.6 19.9 25.0 27.7

EKEXV250 24.7 28.0 30.8 27.8 31.5 34.7


PLUG and PLAY VRV® connection AHU

A ir H andling U nits for ›› VRV Indoor units and Air Handling Units on single VRV system ›› Monovalent cooling and heating for Air Handling Units ›› Air Handling Unit connection like standard VRV indoor unit ›› Factory engineered and mounted controls ›› Constant and comfortable supply air temperature control ›› Fast and easy installation ›› Standard DAIKIN warranty

With the new DAIKIN “PLUG and PLAY” VRV connection

In addition the Daikin Inverter technology for step-less

system VRV indoor units and Air Handling Units for

and efficient capacity control combined with the high-

fresh air treatment can be connected to the same re-

ly sophisticated factory engineered and mounted Air Han-

frigerant line, resulting in enhanced design flexibility

dling Unit controls are ensuring constant and comfort-

and increased energy efficiency. Both fresh air treat-

able supply air temperature.

ment and air conditioning can be achieved successfully

Last but not least not to forget about the business ad-

in a single direct-expansion system via DAIKIN VRV

vantages in which the DAIKIN “PLUG and PLAY” VRV con-

technology without the usual design problems of need-

nection will put you. The possibility of connecting the Air

ing VRV system for air conditioning and separate individ-

Handling Units together with the standard VRV indoor

ual heating and cooling systems just for the Air Handling

units in a monovalent heating and cooling VRV system

Units.

gives you the opportunity to completely get rid off the

The factory engineered and mounted controls package of

fossil fuel burning boilers, the chillers and the water piping

the Air Handling Units assures a fast and easy “PLUG and

from your projects and so reduce the total investment

PLAY” connection of the Air Handling Units just like a

cost significantly.

standard VRV indoor unit.

Altogether, the Daikin “PLUG and PLAY” VRV connection

This innovation brings a total monovalent direct-

system offers you the most efficient, easiest to install tech-

expansion solution to the heating, cooling and fresh

nology with lowest investment costs for the cooling and

air treatment demands of air conditioning applications.

heating needs of your air conditioning projects.

93


PLUG and PLAY VRV® connection AHU

Factory engineered and mounted controls For all Air Handling Units of the “PLUG and PLAY” VRV connection system a factory engineered and factory mounted controls package is included.

This package consists of: ›› Expansion valve kits EKEXV which are already mounted inside the unit so that only the refrigerant piping has to be connected. ›› Factory mounted control equipment for the AHU like temperature-, pressure sensors, dampers … ›› Control panel to control the whole AHU based on supply temperature including EKEQMCB boxes. This assures a fast and easy “PLUG and PLAY” connection of the Air Handling Units to a VRV system just like a standard VRV indoor unit. The possibility of operating the Air Handling Unit by using standard DAIKIN remote control greatly simplifies overall system control. Using a centralized remote control enables the user to choose from a wide range of control systems that integrate air conditioning and ventilation in a single control system structure.

Standardized preconfigured A ir H andling U nits The following preconfigured Air Handling Units are especially designed to meet the requirements which go along with the “PLUG and PLAY” VRV connection system as well as to assure maximum energy efficiency and comfort level for standard air conditioning applications.

Preconfigured Air Handling Unit

+ 94

Factory mounted controls


PLUG and PLAY VRV® connection AHU

S tandard spec . supply air only units for cooling only applications These units are single air stream (Supply fan only) with integrated mixing box (0-100% fresh air) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling mode only. Structure: Natural aluminum frame 40mm, Flat panel 25mm with foam insulation (40 ÷ 50 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm Components in Order of the direction of air flow: 1) Mixing box with dampers including 1 x louver, 1 x flexible connection and factor fitted actuators, 2) F5 bag filter with factory mounted differential pressure gauge and hinged door, 3) Section for factory mounted expansion valve kits EKEXV 4) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 5) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 6) Flexible connection, 7) 150 mm base frame

Air flow

m³/h

2.000

3.000

4.000

6.000

8.000

10.000

12.000

Width Height Length Weight Cooling capacity total Cooling capacity sensible External static pressure Max. Power input fan

mm mm mm kg kW kW Pa kW

950 810 3130 ~ 300 20,60 10,90 450 1,10

1000 940 3350 ~ 350 28,80 16,40 450 1,50

1150 960 3690 ~ 400 40,70 22,00 450 2,20

1350 1060 3691 ~ 470 58,70 32,90 450 3,00

1550 1060 4060 ~600 83,40 43,40 450 5,50

1550 1260 4290 ~700 100,30 55,20 450 5,50

1650 1310 4290 ~700 117,30 65,70 450 7,50

1 x EKEXV200 1 x EKEQMCB

1 x EKEXV250 1 x EKEQMCB

2 x EKEXV200 2 x EKEQMCB

2 x EKEXV250 2 x EKEQMCB

3 x EKEXV250 3 x EKEQMCB

4 x EKEXV200 4 x EKEQMCB

4 x EKEXV250 4 x EKEQMCB

1 x 184

1 x 257

2 x 182

2 x 262

3 x 248

4 x 224

4 x 262

Included VRV connection kit Capacity index

Conditions: Outside air: Summer 35°C/50% r.H.; Supply air: Summer 19°C 1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel 3) EKEXVs mounted inside Air Handling unit. EKEQMCB mounted inside control panel 4) Maximum Connection Ratio (CR) of the total VRV system: 110% 5) Sum of Capacity Indexes of EKEXVs must not exceed 30% when used in a system with other indoor units

95


PLUG and PLAY VRV® connection AHU

S tandard spec . supply and return air units for cooling /  heating applications These units are double air stream (Supply and Return fan) with integrated mixing box (0-100% fresh air), heat recovery system (Pleat heat exchanger or rotary wheel) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling and heating mode. Structure: Natural aluminum frame 40mm, Flat panel 25mm with foam insulation (40 ÷ 50 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm Components in Order of the direction of air flow: Supply air stream: 1) Dampers section including 1 x louver, and factor fitted actuators, 2) F5 bag filter with factory mounted differential pressure gauge and hinged door, 3) Heat recovery system (Pleat heat exchanger or rotary wheel), 4) Mixing box with damper and factor fitted actuators, 5) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 6) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 7) Flexible connection, 8) 150 mm base frame Return air stream: 1) G4 flat filter with factory mounted differential pressure gauge and hinged door, 2) Return fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 3) Mixing box with damper and factor fitted actuators, 4) Heat recovery system (Pleat heat exchanger or rotary wheel), 5) Dampers section including 1 x louver, and factor fitted actuators

Air flow

m³/h

2.000

3.000

4.000

6.000

8.000

10.000

12.000

Width Height Length Weight Cooling capacity total Cooling capacity sensible Heating capacity total External static pressure Max. Power input supply fan Max. Power input return fan

mm mm mm kg kW kW kW Pa kW kW

950 1450 2960 ~ 550 20,6 10,9 11,25 450 1,10 1,10

1000 1710 3440 ~ 680 28,8 16,4 16,50 450 2,20 1,50

1150 1750 3190 ~ 700 40,7 22 21,30 450 2,20 2,20

1350 1950 3330 ~ 900 58,70 32,90 32,26 450 4,00 3,00

1550 1950 3730 ~ 1020 83,40 43,40 44,40 450 5,50 4,00

1650 2350 3700 ~ 1270 100,30 55,20 57,91 450 5,50 5,50

2000 2350 4020 ~ 1560 117,30 65,70 78,31 450 11,00 7,50

1 x EKEXV250 1 x EKEQMCB

1 x EKEXV250 1 x EKEQMCB

2 x EKEXV200 2 x EKEQMCB

2 x EKEXV250 2 x EKEQMCB

3 x EKEXV250 3 x EKEQMCB

4 x EKEXV200 4 x EKEQMCB

4 x EKEXV250 4 x EKEQMCB

1 x 184

1 x 257

2 x 182

2 x 262

3 x 248

4 x 224

4 x 262

Included VRV connection kit Capacity index

Conditions: Outside air: Summer 35°C/50% r.H., Winter -15°C/90% r.H.; Supply air: Summer 19°C, Winter 26°C 1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel 3) EKEXVs mounted inside Air Handling unit. EKEQMCB 4) Maximum Connection Ratio (CR) of the total VRV system: 110% 5) Sum of Capacity Indexes of EKEXVs must not exceed 30% when used in a system with other indoor units

96


PLUG and PLAY VRV® connection AHU

H igh spec . supply and return air units for cooling / heating applications These units are double air stream (Supply and Return fan) with integrated mixing box (0-100% fresh air), heat recovery system (Pleat heat exchanger or rotary wheel) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling and heating mode. Structure: Natural aluminum frame 40mm, Step panel 42mm with mineral wool insulation (90 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm Components in Order of the direction of air flow: Supply air stream: 1) Dampers section including 1 x louver, and factor fitted actuators, 2) Combined filter section G4 pre filter F7 bag filter with factory mounted differential pressure gauge and hinged door, 3) Heat recovery system (Pleat heat exchanger or rotary wheel), 4) Mixing box with damper and factor fitted actuators, 5) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 6) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 7) Empty section, 8) Sound attenuator 500 mm 9) F9 bag filter with factory mounted differential pressure gauge and hinged door 10) Flexible connection, 11) 150 mm base frame Return air stream: 1) F6 bag filter with factory mounted differential pressure gauge and hinged door, 2) Return fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 3) Mixing box with damper and factor fitted actuators, 4) Heat recovery system (Pleat heat exchanger or rotary wheel), 5) Dampers section including 1 x louver, and factor fitted actuators

Air flow

m³/h

2.000

3.000

4.000

6.000

8.000

10.000

12.000

Width Height Length Weight Cooling capacity Cooling capacity Heating capacity total External static pressure Max. Power input supply fan Max. Power input return fan

mm mm mm kg kW kW kW Pa kW kW

950 1450 4740 ~ 830 20,6 10,9 11,25 450 1,50 1,10

1000 1710 5170 ~ 990 28,8 16,4 16,50 450 2,20 1,50

1150 1750 4900 ~ 1070 40,7 22 21,30 450 3,00 2,20

1350 1950 5050 ~ 1301 58,70 32,90 32,26 450 4,00 3,00

1550 1950 5560 ~ 1520 83,40 43,40 44,40 450 5,50 4,00

1650 2350 5580 ~ 1835 100,30 55,0 57,91 450 7,50 5,50

1650 2350 5760 ~ 2230 117,30 65,70 78,31 450 11,00 7,50

1 x EKEXV250 1 x EKEQMCB

1 x EKEXV250 1 x EKEQMCB

2 x EKEXV200 2 x EKEQMCB

2 x EKEXV250 2 x EKEQMCB

3 x EKEXV250 3 x EKEQMCB

4 x EKEXV200 4 x EKEQMCB

4 x EKEXV250 4 x EKEQMCB

1 x 184

1 x 257

2 x 182

2 x 262

3 x 248

4 x 224

4 x 262

Included VRV connection kit Capacity index

Conditions: Outside air: Summer 35°C/50% r.H., Winter -15°C/90% r.H.; Supply air: Summer 19°C, Winter 26°C 1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel 3) EKEXVs mounted inside Air Handling unit. EKEQMCB mounted inside control panel 4) Maximum Connection Ratio (CR) of the total VRV system: 110% 5) Sum of Capacity Indexes of EKEXVs must not exceed 30% when used in a system with other indoor units

97


Air handling units

RANGE A wide standard range covers air flow rates from 1.100 m3/h up to 124.000 m3/h, with the possibility to choose the most appropriate transverse velocity, depending on the treatment required. In addition, with the same air flow, the flow section (width x height) can be adapted to the dimensional constraints of the installation. All sizes are modularly constructed to facilitate transport and easy assembly on site. With the absence of any welding points the Air Handling Units, on request, can be supplied completely dismantled to allow assembly directly on site. ›› P re-defined sizes Twenty-seven (27) fixed sizes optimized to reach the best compromise between competitiveness and manufacturing standardization. ›› “Infinitely” variable sizes designed to overcome installation constraints where space requirements of the section “width x height” must adapt to the available space. The system gives the possibility to tailor the unit sizes through increments/decrements of 5 cm. CONTROL Upon request all units can be provided with a regulation and control system that can manage the unit independently, or communicate with the external supervision system. Control panel power section, inverters, microprocessor, sensors to measure temperature, humidity and air quality, regulation valves, damper actuators, safety devices and control are just some of the components that can be installed upon request on the machine in order to provide an even more comprehensive product and faster installation.

98


Air handling units Technical choices All the units were developed by paying special attention to energy efficiency. Exchange surfaces, motor efficiency, filtration, isolation, friction reduction and pressure drop in the air flow inside the Air Handling Units are just some of the most important parameters considered in the development of the design. All of this provides a product ready to be easily inserted in the system and capable of contributing to overall energy savings.

Frame Structure with carrier chassis built with anodized aluminum (suitable for installation in a particularly aggressive atmosphere) or aluminum profiles of 40x40 or 60x60mm sections. There are solutions with thermal break (60x60mm section) or radial profile (suitable for applications in the food sector or in general, where a high level of hygiene is required). All profiles are double chamber type so that the fixing screws are totally concealed and there are no projections inside the Air Handling Units (in compliance with current accidentprevention regulations), and they are also fitted with a gasket to be inserted inside the profile, in a dovetail slot, to ensure maximum seal. The structure is completed with three way connecting, nylon loaded glass joints put on corners while the base, independent for each section, is in extruded aluminum with aluminum pressure diecast corners to facilitate lifting. Panels The closing panels are double sheets, box-folded and can be flat (25 and 46mm thickness) or step type (42 and 62mm thickness). The step panels permit a flat surface inside the unit, ensuring continuity between the panel and the profile. Insulation can be made of polyurethane foam (40 รท 50 kg/m3) or fibrous mineral wool, glued to the panel (90 kg/m3).

Flat panel

Polyurethane foam

Step panel

Aluminium profile with thermal break

Fan-Motor Assembly The Fan-Motor is made with a single structure comprising two aluminum profiles which help to absorb transmitted shock and a motor, mounted on a tensioning slide. The structure never touches on the bottom of the unit because through the aluminum profiles transfer the weight onto the structure of the AHU, ensuring the maximum vibration isolation. With this solution it can be sure that the AHU does not transmit vibrations to any flat surface on which is installed.

Base

Tensioning slide

Structure with two aluminium profiles

99

Corner


Air handling units Fittings The fasteners are stainless steel, self-tapping screws, located in nylon bosses and retained in the panel with an external cap. This system completely hides the screws in the panel and thanks to the self-fastening and self-centering screws, the tightness over time is ensured.

Fastener Nylon boss

Closure cap

Doors The doors for inspection and internal service can be provided with outward opening or inward opening for pressurized sections. There are solutions with hinges to allow left or right openings, or even the total removal of the door. Portholes The portholes are double-wall type made of polycarbonate and with sealing gaskets. The fastening system that provides the locking screws only enter the polycarbonate structure (and therefore not into the sandwich panel) and the continuous internal-external gasket, prevents the formation of condensation and ensures maximum sealing.

Fitting

Hinges (left or right openings, or even the total removal of the door)

Filters Particular attention is paid, during the configuration of the unit, to the position of the filters in the airflow, in order to maximize their effectiveness. All filters are mounted on commercial frames, provided with a seal to ensure effective filtration efficiency. In addition, all units are designed to allow the extraction of the filters from the dirt side in order to avoid possible contamination with the air circuit during maintenance.

Fastening system Internal-external gasket

Available Components Filter ›› Synthetic pleated filter ›› Flat filter aluminum mesh / stainless steel 304 ›› Rigid / Soft bag filter ›› High efficiency filter ›› Carbon absorption /  deodorizing filter Exchangers ›› Water coils ›› Steam coils ›› Superheated water coils ›› Direct expansion coil ›› Electric coils

Humidifiers ›› Surface evaporation humidifier-constant loss water ›› Surface evaporation humidifier with re-circulating pump ›› Water spray humidifier constant loss water ›› Water spray humidifier with re-circulating pump ›› Steam humidifier with network distribution ›› Steam humidifier with local distributor ›› Atomized water spray humidifier

Fans ›› Forward curved fan ›› Backward curved fan ›› Plug fan (Also available with direct coupling) HEAT RECOVERY SYSTEMS ›› Heat wheel, sensible or enthalpy type ›› Cross-flow heat cube ›› Run-around coils OTHER SECTIONS ›› Attenuator section ›› Mixing box section with actuator or manual dampers ›› Empty section ›› Gas burner section ›› Factory mounted controls incl. Inverters

«  O f fe r i n g a complete range: from standard model sizes to customised soluti o n s.  » 100



ERQ

›› ›› ›› ›› ›› ›› ›› ›› ››

Heat-pump condensing unit

Highly efficient cooling and heating solution for air handling applications Saves on installation costs – no water piping, freezing protection, chillers or boilers needed to satisfy the fresh air heating and cooling loads Daikin Inverter technology for step-less and efficient capacity control ensuring constant and comfortable supply air temperature Wide capacity regulation range – down to 18% nominal capacity on size 250 Wide operation range – in heating down to -20°C and in cooling up to +43°C ambient temperature Flexible choice of regulations, from plug&play Daikin regulation, to sophisticated external control Wide range of options, such as low noise mode or externally-controlled power input limiting R410A direct expansion system for connection to external air heat exchangers

Expansion valve kit EKEXV

ERQ

Air handling unit

Liquid pipe

Gas pipe

Expansion valve control Thermistors

Daikin communication

Control box EKEQDCB EKEQFCB

Controller (Daikin or External)

102


ERQ

Heat-pump condensing unit

Heat pump ERQ100AV1

OUTDOOR UNITS Nominal Capacity * EER COP Combinable expansion valves Operation range - outdoor ERQ-AV1

Operation range on-coil indoor Sound power level Sound pressure level

ERQ125AW1

Defrost method Dimensions

Weight Refrigerant Piping dimensions

ERQ200~250AW1

Piping length Power supply Recommended fuses

Cooling Heating

kW kW

EKEXV # Cooling Heating Cooling Heating Cooling Heating Cooling Heating

°CDB °CWB °C °C dBA dBA dBA dBA

Height Width Depth

mm mm mm kg

R410A Liquid (OD) mm Gas (OD) mm Maximum m A

Expansion valve kits Nominal heat exchanger capacity* Heat exchanger inner volume Dimensions

EKEXV

Weight Sound pressure level Piping connections

minimum maximum minimum maximum Height Width Depth

In (OD) Out (OD)

kW kW l l mm mm mm kg dBA mm mm

ERQ125AV1

EKEQFCB

Regulation range

Inputs & Outputs

Daikin Remote Controller Dimensions

Weight Power supply

BRC1D52 / BRC1E51A Height mm Width mm Depth mm kg

Options/Accessories Electromechanical cool/heat selector (switch) Fixing box for cool/heat selector Drain pan kit with central drain outlet Daikin Remote Controller Adaptor for ext. monitoring/control External room temperature sensor

KRC19-26 KJB111A KWC26B160 KWC26B280 BRC1D52 / BRC1E51A KRP4A51 KRCS01-1

ERQ125AW1

14 15.5 16 18 3.99 3.42 4.15 3.94 63 ~ 140 80 ~ 140 -5 ~ +46 -20 ~ +15,5 +14 WB ~ +25 WB / +35 DB +10 DB ~ 27 DB 66 67 69 – – – 50 51 53 52 53 55 Reverse cycle, electronically controlled 1.345 900 320 120 4 9.52 9.52 9.52 15.9 15.9 19.1 55 1~ / 230V / 50Hz 32

ERQ200AW1

ERQ250AW1

14 16 3.98 4 63 ~ 140

22.4 28 25 31.5 4.29 3.77 4.5 4.09 100 ~ 250 125 ~ 250 -5 ~ +43 -20 ~ +15 +14 WB ~ +25 WB / +35 DB +10 DB ~ 27 DB 72 78 78 – – – 54 57 58 – – – Reverse cycle, electronically controlled 1.68 1.68 1.68 635 930 930 765 765 765 159 187 240 6.2 7.7 8.4 9.52 9.52 9.52 15.9 19.1 22.2 55 3N~ / 400V / 50Hz 16 25 25

EKEXV63

EKEXV80

EKEXV100

EKEXV125

EKEXV140

EKEXV200

EKEXV250

6.3 7.8

7.9 9.9

10 12.3

12.4 15.4 1.66 8.25 457 270 120 2.9 45 9.52 9.52

15.5 17.6

17.7 24.6

24.7 30.8

EKEQDCB

EKEQFCB

Daikin control Room temperature control [via Remote Controller (accessory) or via External room temperature sensor (accessory)]

Free (External) control 0~10V direct capacity control (5V = maintain capacity, >5V colder air wanted, <5V warmer air wanted)

Return air temperature control (via a supplied thermistor) Setpoint 16 ~ 32°C via Daikin Remote Controller (accessory)

On / Off potential free input Fan Control potential free output (e.g. to stop AHU during hot-start and defrost)

Fixed evaporation / condensation temperature control 0~10V input from external controller Fixed evaporation temperature setting to 5 ~ 12°C Fixed condensation temperature setting to 43 ~ 49°C On / Off potential free input Fan Control potential free output (e.g. to stop AHU during hot-start and defrost)

Operation / Error output possible by accessory (KRP4A51)

Defrost potential free output (e.g. to stop AHU during hot-start and defrost)

CONTROL BOXES Control type Control options

ERQ140AV1

11.2 12.5 3.99 4.56 63 ~ 125

Compressor operation potential free output Error indication potential free output Required for end-user control (order separatelly) Required for commissioning & service (order separatelly) 132 400 200 3.6 3.9 1~ / 230V / 50Hz

ERQ-AV1

ERQ125AW1

ERQ200.250AW1

• •

• • •

• •

EKEQDCB

EKEQFCB

• • •

103


CYQS/M/L-DK-F/C/R

Biddle standard air curtain for ERQ

Separate system for heating or cooling

ERQ

›› Air curtain for pair connection to ERQ heat pump ›› Amongst the first DX air curtains on the market ›› Payback of less then 1.5 years thanks to heat pump technology ›› Up to 85% climate separation efficiency thanks to rectifier technology, reducing down-flow turbulence to a minimum ›› Reduces heat losses, discomfort from cold draft, and requirement for internal heat sources Biddle standard air curtain (cy)

Small Biddle standard air curtain for connection to ERQ Power input Fan only Nom. Heating Nom. Delta T Inlet= room temperature Casing Colour Dimensions Height Unit F/C/R Width Unit F/C/R Depth Unit F/C/R Required ceiling void > Door height Max. Door width Max. Weight Unit Fan-Air flow rate Heating Sound pressure level Heating Refrigerant Type Piping connections Liquid (OD) / Gas Required accessories (should be ordered separately) Power supply Voltage

kW kW K mm mm mm mm m m kg m³/h dBA

V

Medium

CYQS150DK80F*BN / *SN CYQS200DK100F*BN / *SN CYQS250DK140F*BN / *SN CYQM100DK80F*BN / *SN CYQM150DK80F*BN / *SN CYQM200DK100F*BN / *SN CYQM250DK140F*BN / *SN 0.35 0.46 0.58 0.37 0.56 0.75 0.94 0.35 0.46 0.58 0.37 0.56 0.75 0.94 15 16 17 14 13 15 BN: RAL9010 / SN: RAL9006 BN: RAL9010 / SN: RAL9006 270 / 270 / 270 270 / 270 / 270 1,500 / 1,500 / 1,548 2,000 / 2,000 / 2,048 2,500 / 2,500 / 2,548 1,000 / 1,000 / 1,048 1,500 / 1,500 / 1,548 2,000 / 2,000 / 2,048 2,500 / 2,500 / 2,548 290 / 821 / 561 290 / 821 / 561 420 420 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 1.5 2.0 2.5 1.0 1.5 2.0 2.5 66 83 107 57 73 94 108 1,746 2,328 2,910 1,605 2,408 3,210 4,013 49 50 51 50 51 53 54 R-410A R-410A 9.52 / 16.0 9.52 / 19.0 9.52 / 16.0 9.52 / 19.0 Daikin wired remote control (BRC1E51A or BRC1D52) Daikin wired remote control (BRC1E51A or BRC1D52) 230 230

Large Biddle standard air curtain for connection to ERQ Power input Fan only Nom. Heating Nom. Delta T Inlet= room temperature Casing Colour Dimensions Height Unit F/C/R Width Unit F/C/R Depth Unit F/C/R Required ceiling void > Door height Max. Door width Max. Weight Unit Fan-Air flow rate Heating Sound pressure level Heating Refrigerant Type Piping connections Liquid (OD) / Gas Required accessories (should be ordered separately) Power supply Voltage

kW kW K mm mm mm mm m m kg m³/h dBA

CYQL100DK125F*BN / *SN 0.75 0.75

CYQL150DK200F*BN / *SN 1.13 1.13 15

1,000 / 1,000 / 1,048

3.0 (1) / 2.75 (2) / 2.5 (3) 1.0 76 3,100 53 9.52 / 16.0

V

F: Freehanging model, C: Cassette model, R: Recessed model (1) Favourable condition | (2) Normal condition | (3) Unfavourable condition

104

CYQL200DK250F*BN / *SN CYQL250DK250F*BN / *SN 1.50 1.88 1.50 1.88 14 12 BN: RAL9010 / SN: RAL9006 370 / 370 / 370 1,500 / 1,500 / 1,548 2,000 / 2,000 / 2,048 2,500 / 2,500 / 2,548 745 / 745 / 745 520 3.0 (1) / 2.75 (2) / 2.5 (3) 3.0 (1) / 2.75 (2) / 2.5 (3) 3.0 (1) / 2.75 (2) / 2.5 (3) 1.5 2.0 2.5 100 126 157 4,650 6,200 7,750 54 56 57 R-410A 9.52 / 16.0 9.52 / 22.0 Daikin wired remote control (BRC1E51A or BRC1D52) 230


CYVS/M/L/XL-DK-F/C/R

Biddle standard air curtain for VRV

VRV® NETWORK SOLUTION

›› Air curtain for pair connection to VRV systems ›› Amongst the first DX air curtains on the market ›› Payback of less then 1.5 years thanks to heat pump technology ›› Up to 85% climate separation efficiency thanks to rectifier technology, reducing down-flow turbulence to a minimum ›› Reduces heat losses, discomfort from cold draft, and requirement for internal heat sources Biddle comfort air curtain (ca)

Small Indoor units Heating capacity

Speed 3 Speed 4 Power input Fan only Nom. Heating Nom. Delta T Speed 3 Speed 4 Casing Colour Dimensions Height Unit F/C/R Width Unit F/C/R Depth Unit F/C/R Required ceiling void > Door height Favorable/Normal/ Unfavorable conditions Door width Max. Weight Unit Unit F/C/R Fan-Air flow rate Heating Speed 3 Heating Speed 4 Sound pressure level Heating Speed 3 Heating Speed 4 Refrigerant Type Piping connections Liquid (OD) / Gas Required accessories (should be ordered separately) Power supply Voltage

kW kW kW kW K K mm mm mm mm m m kg m³/h m³/h dBA dBA

Medium

CYVS100DK80*BC/*SC CYVS150DK80*BC/*SC CYVS200DK100*BC/*SC CYVS250DK140*BC/*SC CYVM100DK80*BC/*SC CYVM150DK80*BC/*SC CYVM200DK100*BC/*SC CYVM250DK140*BC/*SC 4.8 6.1 7.9 10.9 6.1 7.5 9.7 13.4 6.0 7.5 9.7 13.3 7.7 9.4 12.1 16.8 0.20 0.30 0.40 0.50 0.28 0.42 0.56 0.70 0.20 0.30 0.40 0.50 0.28 0.42 0.56 0.70 22 19 18 20 20 17 16 18 20 17 16 18 15 14 16 BC:RAL9010 / SC:RAL 9006 270 / 270 / 270 1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548 1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548 590 / 821 / 561 420 2.4 / 2.2/ 1.0 61 / 59 / 61 670 880 36 42

mm

1.5 73 / 83 / 88 1,000 1,310 38 44 9.52 / 16.0

V

2.8 / 2.5 / 2.2

2.0 2.5 1.0 1.5 89 / 102 / 108 101 / 129 / 137 66 / 68 / 66 79 / 88 / 93 1,340 1,670 750 / 890 1,120 / 1,330 1,750 2,190 890 / 1,230 1,330 / 1,840 39 40 32 / 37 34 / 39 45 46 37 / 45 39 / 47 R-410A 9.52 / 19.0 9.52 / 16.0 Daikin wired remote control (BRC1E51A or BRC1D52) 230

Large Indoor units Heating capacity

Speed 3 Speed 4 Power input Fan only Nom. Heating Nom. Delta T Speed 3 Speed 4 Casing Colour Dimensions Height Unit F/C/R Width Unit F/C/R Depth Unit F/C/R Required ceiling void > Door height Favorable/Normal/ Unfavorable conditions Door width Max. Weight Unit Unit F/C/R Fan-Air flow rate Heating Speed 3 Heating Speed 4 Sound pressure level Heating Speed 3 Heating Speed 4 Refrigerant Type Piping connections Liquid (OD) / Gas Required accessories (should be ordered separately) Power supply Phase / Frequency / Voltage

kW kW kW kW K K mm mm mm mm m

9.52 / 19.0

XLarge

CYVL100DK125*BC/*SC CYVL150DK200*BC/*SC CYVL200DK250*BC/*SC CYVL250DK250*BC/*SC CYVXL100DK125*BC/*SC CYVXL150DK200*BC/*SC CYVXL200DK250*BC/*SC CYVXL250DK250*BC/*SC 10.6 15.9 20.3 22.1 12.3 18.6 23.6 25.4 12.5 18.8 24.0 25.8 14.7 22.0 27.8 29.6 0.75 1.13 1.50 1.88 1.40 2.10 2.80 3.50 0.75 1.13 1.50 1.88 1.40 2.10 2.80 3.50 18 15 17 16 14 17 16 14 15 12 BC:RAL9010 / SC:RAL 9006 370 / 370 / 370 1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548 1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548 774 / 1,105 / 745 520 3.3 / 3.0 / 2.5

m kg m³/h m³/h dBA dBA

1.0 83 / 81 / 83 1,330 / 1,730 1,730 / 2,210 40 / 46 45 / 51

mm

9.52 / 16.0

Hz / V

2.0 2.5 97 / 111 / 117 119 / 136 / 144 1,490 / 1,770 1,870 / 2,215 1,770 / 2,450 2,220 / 3,060 35 / 40 36 / 41 40 / 48 4 / 49

3.8 / 3.5 / 3.0

1.5 2.0 2.5 1.0 1.5 2.0 2.5 108 / 118 / 141 137 / 151 / 155 166 / 190 / 196 69 / 84 / 86 102 / 123 / 146 130 / 160 / 164 162 / 198 / 204 2,000 / 2,600 2,670 / 3,470 3,330 / 4,340 1,610 / 2,160 2,420 / 3,250 3,230 / 4,330 4,030 / 5,410 2,600 / 3,320 3,470 / 4,430 4,340 / 5,530 2,160 / 2,800 3,250 / 4,190 4,330 / 5,590 5,410 / 6,990 42 / 48 43 / 49 44 / 50 46 / 52 48 / 53 49 / 55 50 / 56 47 / 53 48 / 54 49 / 55 51 / 56 53 / 58 54 / 59 55 / 60 R-410A 9.52 / 19.0 9.52 / 22.0 9.52 / 16.0 9.52 / 19.0 9.52 / 22.0 Daikin wired remote control (BRC1E51A or BRC1D52) 230

1 in case of connection to a VRV® heat recovery outdoor unit F: Freehanging model, C: Cassette model, R: Recessed model

*Note: grey cells contain preliminary data

105

Contact your local dealer for availability



BRC1E52A BRC1E52B

User friendly remote control with contemporary design

What’s new? Energy saving functions

A series of energy saving functions that can be individually selected ›› ›› ›› ›› ›› ››

Temperature range limit Setback function Presence & floor sensor connection (available on new round flow cassette) kWh indication Set temperature auto reset Off timer

Temperature range limit avoids excessive heating or cooling Save energy by constraining the lower temperature limit in cooling and upper temperature limit in heating mode. note : Also available in auto cooling/heating change over mode.

kWh indication keeps

track of your consumption The kWh indication shows an indicative electricity consumption of the last day/month/year.

Other functions NEW ›› IMPROVED ››

›› ›› ›› ›› ›› ››

Up to 3 independent schedules can be set, so the user can easily change the schedule himself throughout the year (e.g. Summer, winter, mid-season) Possibility to individually restrict menu functions Easy to use: all main functions directly accessible Easy setup: clear graphical user interface for advanced menu settings Real time clock with auto update to daylight saving time Supports multiple languages (English, German, Dutch, Spanish, Italian, Portuguese, French, Greek, Russian, Turkish, Polish (NEW)) From the 2nd half of 2012, further language will become available in the version BRC1E52B (Albanian, Bulgarian, Croatian, Czech, Hungarian, Romanian, Serbian, Slovakian, Slovenian) Built-in backup power: when a power failure occurs all settings remain stored up to 48 hours 107

Graphical display of indicative electricity consumption


Individual control systems

BRC944B2

BRC944B2

ARC466A1

BRC4*/BRC7*

BRC2C51

BRC944B2*/BRC1D52 Wired remote control

››

›› ›› ›› ›› ››

Schedule timer:

• Five day actions can be set as follows: -- set point: unit is switched ON and normal operation is maintained -- OFF: unit is switched OFF1 -- limits: unit is switched ON and min./max. control (cf. limit operation for more details) Home leave (frost protection): during absence, the indoor temperature can be maintained at a certain level. This function can also switch the unit ON/OFF User friendly HRV function, thanks to the introduction of a button for ventilation mode and fan speed Constantly monitoring of the system for malfunctions in a total of 80 components Immediate display of fault location and condition Reduction of maintenance time and costs

Display Operating mode1 Heat Recovery Ventilation (HRV) in operation Cool / heat changeover control Centralised control indication Group control indication Set temperature1 Air flow direction1 Programmed time Inspection test / operation Fan speed1 Clean air filter Defrost / hot start Malfunction

›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››

1

Only functions marked with ‘1’ are available on BRC944B2

ARC4*/BRC4*/BRC7*

BRC2C51

Operation buttons: ON / OFF, timer mode start / stop, timer mode on  / off, programme time, temperature setting, air flow direction, operating mode, fan speed control, filter sign reset , inspection / test indication

Simple, compact and easy to operate unit, suitable for use in hotel bedrooms

Infrared remote control

Display: Operating mode, battery change, set temperature, air flow direction , programmed time, fan speed, inspection / test operation  For all features of the remote control, refer to the operation manual

Simplified remote control

Operation buttons: ON/OFF, operating mode selection, fan speed control, temperature setting Display: Cool/heat changeover control, Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode, centralised control indication, fan speed, defrost/hot start, malfunction adjustment, operating mode selection, fan speed control, filter sign reset, inspection test/operation

108


Centralised control systems

DCS302C51

DCS301B51

Basic control

DST301B51

Centralised control of the VRV system can be achieved via 3 user friendly compact controls: centralised remote control, unified on/off control and schedule timer. These controls may be used independently or in combination where 1 group = several (up to 16) indoor units in combination and 1 zone = several groups in combination. A centralised remote control is ideal for use in tenanted commercial buildings subject to random occupation, enabling indoor units to be classified in groups per tenant (zoning). The schedule timer programmes the schedule and operation conditions for each tenant and the control can easily be reset according to varying requirements.

DCS302C51

DCS301B51

DST301B51

Providing individual control of 64 groups (zones) of indoor units.

Providing simultaneous and individual control of 16 groups of indoor units.

Enabling 64 groups to be programmed.

• a maximum of 64 groups (128 indoor units, max. 10 outdoor units) can be controlled • a maximum of 128 groups (128 indoor units, max. 10 outdoor units) can be controlled via 2 centralised remote controls in separate locations • zone control • group control • malfunction code display • maximum wiring length of 1,000m (total: 2,000m) • air flow direction and air flow rate of HRV can be controlled • expanded timer function

• a maximum of 16 groups (128 indoor units) can be controlled • 2 remote controls in separate locations can be used • operating status indication (normal operation, alarm) • centralised control indication • maximum wiring length of 1,000m (total: 2,000m)

• a maximum of 128 indoor units can be controlled • 8 types of weekly schedule (when combined with DCS302C51) • a maximum of 48 hours back up power supply • a maximum wiring length of 1,000m (total: 2,000m)

Centralised remote control

Unified ON/OFF control

109

Schedule timer


DCS601C51 Intelligent Touch Controller

Centralised control systems third party controller (domotics, BMS, etc.) (option DCS007A51)

Detailed & easy monitoring and operation of VRV systems (max. 2 X 64 groups/indoor units).

Ethernet

Fire alarm Forced OFF contact input

PCMCIA flash memory

DIII-NET

CSV output of PPD (option) result (option DCS002C51)

Indoor units

HRV

Pi-port Onboard Ethernet port

DIO unit (DEC102A51) Links to the wattmeter when using the PPD Controls drain pump lighting etc. (DEC102A51)

(option) function

Malfunction

DI unit (DEC101A51) Remote monitoring/control via internet, e-mail PPD data is available on the internet (option DCS004A51)

Monitoring of room enter/ exit sign (DEC101A51)

DIII-NET Allows monitoring/control of up to 64 units (groups) of A/Cs and equipment RS-232C

DIII-NET PLUS adapter (DCS601A52) Indoor units

HRV

LANGUAGES

CONTROL

COST PERFORMANCE

›› ›› ›› ›› ›› ›› ››

››

›› ›› ›› ›› ››

English French German Italian Spanish Dutch Portuguese

SYSTEM LAYOUT ›› ›› ›› ››

Up to 2 x 64 indoor units can be controlled Onboard Ethernet port (web browser + e-mail) Digital i/o contacts (option) Touch panel (full colour LCD via icon display)

MANAGEMENT ››

›› ›› ›› ››

Web application & internet compatibility (option DCS004A51) - Monitoring & control according to user - Remote monitoring & control of more than one building - Remote monitoring & control of more than one building via internet

Power Proportional Distribution: PPD (option DCS002C51) PPD data is available on the internet Easy management of electricity consumption Enhanced history function

›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››

Individual control (set point, start/stop, fan speed) (max. 2 x 64 groups/indoor units) Set back shedule Enhanced scheduling function (8 schedules, 17 patterns) Flexible grouping in zones Yearly schedule Fire emergency stop control Interlocking control Increased HRV monitoring and control function Automatic cooling / heating change-over Heating optimization Temperature limit Password security: 3 levels (general, administration & service) Quick selection and full control Simple navigation

MONITORING ›› ›› ›› ›› ›› ››

Visualisation via Graphical User Interface (GUI) Icon colour display change function Indoor units operation mode Error messages via e-mail & mobile phone (option) Indication filter replacement Multi PC

110

Free cooling function Labour saving Easy installation Compact design: limited installation space Overall energy saving

OPEN INTERFACE ›› ›› ››

Communication to any third party controller (domotics, BMS, etc.) is possible via open interface HTTP communication protocol Available as option DCS007A51

CONNECTABLE TO ›› ›› ›› ››

VRV HRV Sky Air (via interface adapter) Split (via interface adapter)


DAM602B51/52 Intelligent Manager

Centralised control systems

[iPU]

Full control and management of VRV systems (Maximum 200 groups)

~

Intranet/Internet Web Access

Web Access Malfunction report by E-Mail

Ai unit (DAM101A51)

DAM602B51/52

DIII-NET DIII-NET DIII-NET

DIII-NET

ETHERNET

Windows Vista Compatible

Fire alarm

~

Sub PC

Dio unit (DDEC102A51)

DMS502A51 (monitoring only)

Local monitoring & control

Power supply facility · Elevator · Pump · Lighting,...

Electricity Measurement

VRV System

Daikin Central Air Conditioning System HRV

LANGUAGES

MANAGEMENT

MONITORING

›› ›› ›› ›› ›› ›› ››

›› ››

››

English French German Italian Spanish Dutch Portuguese

SYSTEM LAYOUT ›› ›› ››

›› ››

Up to 1,024 indoor units can be controlled (by 4 iPUs) Ethernet TCPIP / 10 base / T communication Integrated digital contacts on the Intelligent Processing Unit (iPU) - 20 general input ports - 2 digital outputs Stand alone operation of the iPU for minimum 48 hours Compatible with UPS shutdown software

›› ›› ›› ›› ›› ›› ››

Web access (option) (option DAM004A51) Power Proportional Distribution (option DAM002A51) Operational history management (start/ stop, malfunction, operation hours) Generation of reports (graphics & tables) (daily, weekly, monthly) Peak load shedding Advanced tenant management Sliding temperature Eco mode (option DAM003A51) Pre-cooling and -heating function

CONTROL ›› ›› ›› ›› ›› ›› ›› ›› ›› ››

Individual control (setpoint, start/stop, fan speed) (max. 1,024 indoor units) Group control (100 groups) Schedule control (128 programs) Fire emergency stop control (32 programs) Interlocking control Setpoint limitation Automatic cooling/heating change-over Power failure/release control Temperature limit (automatic start) Timer extension

111

›› ›› ›› ›› ›› ›› ››

Visualisation via a Graphical User Interface (GUI) featuring free layout Operation mode of indoor units Fault indication Indication filter replacement Setpoint indication Operation time monitoring Multi PC On-line help

COST PERFORMANCE ›› ›› ›› ››

Labour saving Easy installation Compact design: limited installation space Overall energy saving

CONNECTABLE TO ›› ›› ›› ››

VRV HRV Sky Air (via interface adapter) Split (via interface adapter)


Advanced individual unit control & interfaces

RTD-10 / -NET / -HO Universal control adaptors

Monitor and control one group of VRV or Sky Air indoor units via a third party control or BMS system External interface gateways RTD-10 Advanced integration into BMS system of VRV, Sky Air, VAM and VKM through either: ›› Modbus ›› Voltage (0-10V) ›› Resistance

RTD-NET Modbus interface for monitoring and control of VRV, Sky Air, VAM and VKM

RTD-HO Intelligent hotel room controller

Overview of functions MAIN FUNCTIONS Dimensions HxWxD Key card + window contact Set back function Prohibit or restrict remote control functions (setpoint limitation, ...) Modbus (RS485) 0 - 10 V control Resistance control IT application (automatic back-up and rotation between units Heating interlock Output signal (on/defrost, error)

RTD-10 mm

RTD-NET 100 x100 x 22

RTD-HO

   

      

 

RTD-10 M,V,R M,V,R M,V,R M,V,R M,V,R M,V,R M,V,R

RTD-NET M M M M M M M

RTD-HO M* M* M* M* M*

RTD-10 RTD-NET MONITORING FUNCTIONS M, C M On/Off M M Set point M M Mode M M fan M M Louver M M RC temperature M M RC mode M M nbr units M, C M Fault M M Fault code M M Return air temperature (Average /Min/Max) M M Filter alarm M M Termo on M, C** M Defrost M M Coil In/Out temperature M: Modbus, V: Voltage, R: Resistance, C: Potential-free Contact, *: only when the room is occupied, **: Either On/Off or Defrost can be indicated, not both

RTD-HO M, C M M M M M M M M, C M M M M M M

CONTROL FUNCTIONS On/Off Set point Mode fan Louver HRV Damper control Prohibit/Restrict functions

112

M*


Advanced individual unit Daikin systems controlcontrol & interfaces

DTA113B51 DS-Net Adaptor

Basic solution for control of Sky Air and VRV

DS-NET adapter

GSM modem (field supply) RS232C

BRC1D52

Up to 4 units / 1 adapter

Mobile phone (field supply)

›› ›› ››

monitoring function control function error notification

FUNCTIONS 1. Monitoring Functions

You can monitor your air conditioning units by simply sending a text message with your mobile phone with the word “Report”: ›› Start/stop ›› Operation mode (fan/cool/heat) ›› Temperature setting ›› Error code

3. Error Notification

When an error occurs, a text message will be sent automatically to your mobile phone (error notification).

4. Stand alone operation

›› ››

2 . Control Functions

You can control your air conditioning units by simply sending a text message via your mobile phone: ›› Start/stop ›› Operation mode (fan/cool/heat) ›› Temperature setting

Daikin recommends the use of a Wavecom Fastrack modem

113

Rotation function Backup operation function.


Advanced individual unit control & interfaces

KKRP01A Online Controller

Always in control, no matter where you are

Daikin provides a new control solution to monitor and control the main functions of the residential indoor units. The system is working in an end-user friendly way and can be used from any location via your smartphone, laptop, PC, tablet, app

or wired remote controller.

1

Wired controller

2 PC

3 Smartphone

Residential use:

Light commercial use:

Optimal home comfort / holiday home surveillance ›› Create a comfortable home climate at any time and at any place ›› Remote detection of failures

Flexible office solution ›› Dynamic group control in open space ›› Fault manager / event logger ›› Easily create a yearly schedule (iPlanner) ›› Back-up configuration of air conditioning

Available software packages Residential*

Light commercial **

Extended light commercial **

 

 

 

Possibility to control multiple indoor units via internet (over 9 KKRP01s)

Filtering data OK / ERR

Possibility to control indoor unit via internet Possibility to control multiple indoor units via internet (up to 9 KKRP01s)

Advanced filtering (OK / ANY ERR / COMM ERR / AC / ERR)

Sorting by all columns from data-grid

History of alerts

History of temperatures

History of commands

Graphic single controller with weather forecast

Text group controller

Weekly planner

 

I-planner (yearly schedule) Receive via e-mail an alert report

Autonomous periodical connectivity check

Exceeded room temperature limits e-mail report

* standard programmed on KKRP01A ** Additional software to be purchased online

114


Advanced individual unit control & interfaces

KKRP01A Online controller

Possible indoor units: Standard ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››

FTXR28-50E FTXG25-50J FTXG25-35E CTXG50J CTXG50E FTXS20-71G FTK/XS20-50D FTXS50-71F FTXS20-50J FTX50-71GV FTYN50-60F FVXS25-50F FVXG25-50K FLK/XS25-60C/E ATXS20-50E ATXS20-50G ATXG25-35E

App It will be possible to control your air conditioning via an app. This app will become available for download.

Specifications Online controller KKRP01A Communication interfaces Ethernet LAN 10/100 Mbit/s MODBUS

for connection intro LAN network for connection of accessories

serial S21 cable 1,3m

for connection with A/C indoor unit

Power supply

directly from IU - 5 V DC for Online Controller, 12 V DC for accessories

Power consumption

120 mA, 0.6 W

IP code Others

IP10 / IP44 - inside A/C unit

Mounting Weight

inside of A/C IU or intro External Mounteing Kit 50g

Dimensions (W X h X d)

64 X67 X 17 mm (without cable)

Options MATERIAL NAME

DESCRIPTION

EXPLANATION

KKRPM01A

External mounting kit

To install online controller outside the indoor unit or to extend the length of the cable between indoor unit and KKRP01A. It can easily be mounted on the wall of hidden in false ceilings.

KKRPW01A

Wifi Cable Pack

To enable wireless internet connection. Wifi module to be purchased locally.

KBRCS01A

Easy wall controller

KBRC01A

Touch LCD wall controller

Wired controller to be installed on the wall. Designed to easily control one indoor unit or a group of indoor units.

115


KLIC-DI / -DD KNX Protocol

Standard protocol interfaces

Integration of Split, Sky Air and VRV

in HA/BMS systems

Concept

Connect split indoor units to KNX interface for Home Automation system

light house

Interface Daikin protocol/ KNX

Domotica Controller

Concept

Connect Sky Air / VRV indoor units to KNX interface for BMS integration

shutter control tv

light shop

Interface Daikin protocol/ KNX

Domotica Controller

shutter control

tv

KNX interface line-up The integration of Daikin indoor units through the KNX interface allows monitoring and control of several devices, such as lights and shutters, from one central controller. One particularly important feature is the ability to programme a ‘scenario’ - such as “Home leave” - in which the end-user selects a range of commands to be executed simultaneously once the scenario is selected. For instance in “Home leave” , the air conditioner is off, the lights are turned off, the shutters are closed and the alarm is on.

KNX interface for KLIC-DD Size 90x60x35mm Split

KLIC-DI Size 45x45x15mm Sky Air

VRV

BASIC CONTROL On/Off Mode Temperature Fan speed levels Swing

Auto, heat, dry, fan, cool

3 or 5 + auto Stop or movement

Advanced functionalities Error management Scenes Auto switch off Temperature limitation Initial configuration Master and slave configuration

   

Standard protocol interfaces Modbus interface for monitoring and control of up to 16 VRV, Sky Air, VAM or VKM indoor units

Auto, heat, dry, fan, cool

Auto, heat, dry, fan, cool

2 or 3 Stop or movement

2 or 3 Swing or fixed positions (5)

Communication errors, Daikin unit errors

    

    

RTD-NET Modbus Protocol

To indoor unit power supply

To indoor unit via P1/P2

116

To BMS system (modbus)


DMS502A51 BACnet Protocol

Standard protocol interfaces

BACnet Interface Integrated control system for seamless connection between VRV and BMS systems

›› ›› ›› ›› ›› ››

PPDdata is available on BMS system Interface for BMS system Communication via BACnet protocol (connection via Ethernet) 256 units connectable per BACnet gateway Unlimited sitesize Easy and fast installation

DIII- NET

DAM602B51/52

Local Control

BACNET / ETHERNET

VRV Outdoor unit HRV

DAIKIN A/C INFRASTRUCTURE Remote Control

Fire alarm

BUILDING CONTROL NETWORK

Pump

Security

Power supply facility

Lighting

Elevator

DMS504B51 LonTalk Protocol

Standard protocol interfaces

LonWorks Interface Open network integration of VRV monitoring and

LON BMS

›› ›› ›› ››

control functions into LonWorks networks

Interface for Lon connection to LonWorks networks Communication via Lon protocol (twisted pair wire) 64 units connectable per DMS-IF Unlimited sitesize Quick and easy installation

dms504b51

LonTalk

DIII- NET

adapter ETHERNET (TCP/IP)

››

Local Control VRV Outdoor unit HRV

LonTalk adapter Remote Control LonPoint

LonPoint

BUILDING CONTROL NETWORK

DAIKIN A/C INFRASTRUCTURE

Security

117

Fire alarm System


K.RSS

Wireless room temperature sensor

Flexible and easy installation Accurate temperature measurement thanks to flexible placement of the sensor ›› No need for wiring ›› No need to drill holes ›› Ideal for refurbishment ››

Connection diagram Daikin indoor unit PCB (FXSQ-P example) Air sensor – X16A, X19

Power supply – X35, X13 RF sender

Rf Receiver

Specifications

Wireless room temperature sensor kit (K.RSS) WIRELESS ROOM TEMPERATURE RECEIVER WIRELESS ROOM TEMPERATURE SENSOR

Dimensions

mm

Weight

g

Power supply Battery life Battery type Operation range

››

+/- 3 years 10

°C

0~50

MHz

868.3

Type Frequency

3 Volt Lithium battery

m

RF

Room temperature is sent to the indoor unit every 90 seconds or if the temperature difference is 0.2°C or larger.

KRCS01-1B KRCS01-4B ››

N/A

N/A N/A

Maximum range

Communication

16VDC, max. 20 mA

Wired room temperature sensor

Accurate temperature measurement, thanks to flexible placement of the sensor

Specifications Dimensions (HxW)

mm

Weight

g

60 x 50 300

Length of branch wiring

m

12

118


Other integration devices

Adapter PCB’s – Simple solutions for unique requirements Daikin’s adapter PCB’s provide simple solutions for unique requirements. They are a low cost option to satisfy simple control requirements and can be used on single or multiple units.

Output signal wiring adaptors Provide potential-free output contacts indicating compressor operation (or error signal) and indoor unit fan operation Versions with 4 outputs additionally provide 230V output contacts for control of 3rd party auxiliary booster heaters and humidifiers Connects to the indoor units PCB, for installation in the indoor unit

• • • • • •

Simultaneous On/Off and set-point control of entire DIII-Net line (up to 128 indoor units / 64 groups) Set-point control by resistance signal (0-140Ω) Possibility to restrict On/Off control by local remote controllers Sum operation and error potential-free output contacts Connects to F1/F2 line and indoor unit PCB, for installation in the indoor unit Not combinable with other Daikin centralized control solutions

Wiring adaptor for electrical appendices

• • • • • •

On/Off and set-point control of up to 16 VRV® or SkyAir® indoor units (1 remote controller group) Set-point control by resistance signal (0-140Ω) Possibility to restrict On/Off control by local remote controllers Operation and error potential-free output contacts Connects to P1/P2 line and indoor unit PCB, for installation in the indoor unit Must be installed together with a local remote controller (BRC*)

DTA104A*

E xternal activation of demand limitation (limitation of system’s power input to <10%, 40%, 60%, 70%, or 80%) External activation of low noise mode (limitation of outdoor unit’s sound level) Simultaneous operation mode switching of multiple heat pump systems

(E)KRP1B* (E)KRP1C* Adapter for wiring

KRP2A* Wiring adaptor for electrical appendices

KRP4A*

Outdoor Unit External Control Adapter

Concept and benefits

• • •

• •

›› ››

Low cost option to satisfy simple control requirements Deployed on single or multiple units

119


Options & accessories -

outdoor

Total Solution VRV

Multi-module connection kit (obligatory) Connects multiple modules into a single refrigerant system Extended level difference kit Allows outdoor unit to be more than 50m above indoor units

VRV III Heat Recovery

REYAQ 10~16

REYQ 8~16

REMQ 8~12

REMHQ 12

REMQ 14~16

2-module systems

3-module systems

-

-

-

-

-

BHFQ23P907

BHFQ23P1357

-

Special order unit

Special order unit

Special order unit

Special order unit

Special order unit

Special order unit

KWC25C450

KWC25C450

KWC26B280

KWC26B450

KWC26B450

1 kit per module

1 kit per module

-

-

-

-

-

-

-

Central drain pan kit Installs onto the underside of the outdoor unit and collects drain water from all bottom plate outlets into a single outlet. In cold areas should be heated by a field-supplied heater to prevent drain water from freezing in the drain pan. Bottom plate heater kit Optional electrical heater for the VRV casing’s bottom plate to guarantee trouble-free operation even in extremely cold and humid climates External control adaptor for outdoor unit DTA104A53/61/62 For installation into an indoor unit: exact adaptor type depends on type of indoor unit. See Options & Accessories of indoor units

Allows to activate Low Noise Operation and three levels of Demand Limiting via external dry contacts. Connects to the F1/F2 communication line and requires power supply from an indoor unit*, BSVQ box, or VRV-WIII outdoor unit. BHGP26A1 Digital pressure gauge kit – displays current condensing and evaporating pressures in the system as standard, or expansion valve positions and temperature sensor data in a special service mode. Connect to the outdoor unit PCB, for installation in the outdoor unit.

-

1 kit per system

1 kit per system

-

-

-

-

-

-

-

-

-

-

-

-

-

-

KRC19-26 Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the A-B-C terminals of the outdoor unit / BS-box. KJB111A Installation box for remote cool/heat selector KRC19-26

VRV III Heat Pump with for stylish indoor units

Multi-module connection kit (obligatory) Connects multiple modules into a single refrigerant system Extended level difference kit Allows outdoor unit to be more than 50m above indoor units

VRV III-S Mini VRV

VRV III-Q Heat Recovery Replacement VRV

RXYRQ 8~12

RXYRQ 14~18

RXYSQ

RQEQ 140~212

2-module systems

3-module systems

4-module systems

-

-

-

-

BHFP26P36C

BHFP26P63C

BHFP26P84C

-

-

-

-

-

-

-

KWC26B280

KWC26B450

-

KWC26B160

-

-

-

-

Central drain pan kit Installs onto the underside of the outdoor unit and collects drain water from all bottom plate outlets into a single outlet. In cold areas should be heated by a field-supplied heater to prevent drain water from freezing in the drain pan.

1 kit per module 1 kit per module

1 kit per module

Bottom plate heater kit Optional electrical heater for the VRV casing’s bottom plate to guarantee trouble-free operation even in extremely cold and humid climates

-

-

-

External control adaptor for outdoor unit DTA104A53/61/62 For installation into an indoor unit: exact adaptor type depends on type of indoor unit. See Options & Accessories of indoor units

Allows to activate Low Noise Operation and three levels of Demand Limiting via external dry contacts. Connects to the F1/F2 communication line and requires power supply from an indoor unit*, BSVQ box, or VRV-WIII outdoor unit. BHGP26A1 Digital pressure gauge kit – displays current condensing and evaporating pressures in the system as standard, or expansion valve positions and temperature sensor data in a special service mode. Connect to the outdoor unit PCB, for installation in the outdoor unit.

-

-

-

1 kit per system

1 kit per system

1 kit per system

Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the A-B-C terminals of the outdoor unit / BS-box.

-

-

-

-

KJB111A

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

KRC19-26

Installation box for remote cool/heat selector KRC19-26 BWU26A15 Water strainer kit for 1.40MPa design pressure BWU26A20 Water strainer kit for 1.96MPa design pressure

120


VRV III-C Cold Region VRV

VRV III Heat Pump

RTSYQ 10

RTSYQ 14~16

RTSYQ 20

RXYQ 5

RXYQ 8~12

RXYHQ 12

RXYQ 14~18

2-module systems

3-module systems

-

-

BHFQ22P1007

-

-

-

-

BHFQ22P1007

BHFQ22P1517

-

-

-

-

EKLD90P12

EKLD90P12

EKLD90P18

1 kit per module

1 kit per module

KWC26B280

KWC26B450

2x KWC26B280

KWC26B160

KWC26B280

KWC26B450

KWC26B450

1 kit per module

1 kit per module

BEH22A10Y1L

BEH22A18Y1L

2x BEH22A10Y1L

-

-

-

-

-

-

DTA104A53/61/62 For installation into an indoor unit: exact adaptor type depends on type of indoor unit. See Options & Accessories of indoor units

1 kit per system

1 kit per system

-

-

-

1 kit per system

1 kit per system

-

-

-

1 kit per system

1 kit per system

VRV III-Q Heat Pump Replacement VRV

VRV-WIII Water-cooled VRV Heat Pump application Heat Recovery application 2-module 3-module 2-module 3-module systems systems systems systems

RQYQ 140

RQYQ 8~12

RQYQ 14~16

2-module systems

3-module systems

RWEYQ 8~10

-

-

-

BHFQ22P1007

BHFQ22P1517

-

BHFP22MA56

BHFP22MA84

BHFP26MA56

BHFP26MA84

-

-

-

-

-

-

-

-

-

-

KWC26B160

KWC26B280

KWC26B450

1 kit per module

1 kit per module

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

DTA104A53/61/62 For installation into an indoor unit: exact adaptor type depends on type of indoor unit. See Options & Accessories of indoor units

DTA104A62 Installation in the RWEYQ outdoor unit possible. For installation in indoor units, use appropriate type (DTA104A53/61/62) for particular indoor unit. See Options & Accessories of indoor units

1 kit per system

1 kit per system

-

-

-

-

-

1 kit per system

1 kit per system

1 kit per system

1 kit per system

-

-

1 kit per system

1 kit per system

1 kit per system

1 kit per system

-

-

-

-

-

-

-

1 kit per module

1 kit per module

1 kit per module

1 kit per module

-

-

-

-

-

1 kit per module

1 kit per module

1 kit per module

1 kit per module

✓ ✓ ✓

121


Options & accessories -

indoor Ceiling mounted cassette units Round flow (800x800) FXFQ 20~125

BRC1E51A Premium wired remote controller with full-text interface and back-light BRC1D52 Standard wired remote controller with weekly timer

Adaptors and Control

External wireless temperature sensor

FXZQ 15~50

FXCQ 20~32

FXCQ 40~50

✓ ✓

✓ ✓

✓ ✓

-

-

-

-

-

BRC7F532F

-

BRC7E530

BRC7C62

BRC7C62

KRCS01-4

KRCS01-4

KRCS01-1

KRCS01-1

KRCS01-1

-

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

Wiring adaptor for external monitoring/control via dry contacts and setpoint control via 0-140Ω

KRP4A53

-

KRP4A53

KRP4A51

KRP4A51

Wiring adaptor for external central monitoring/control (controls 1 entire system)

KRP2A52

KRP2A52

KRP2A52

KRP2A51

KRP2A51

EKRP1C11

KRP1C12

-

EKRP1B2

EKRP1B2

Wiring adaptor with 4 output signals Compressor / Error, Fan, Aux. heater, Humidifier output Wiring adaptor with 2 output signals

-

-

KRP1B57

-

-

Adaptor for multi-tenant applications (24VAC PCB power supply interface)

DTA114A61

DTA114A61

EKMTAC

-

-

External control adaptor for outdoor unit

DTA104A62

DTA104A62

DTA104A62

DTA104A61

DTA104A61

KRP1H98

KRP1J98

KRP1BA101

KRP1B96

KRP1B96

Connector for forced-off contact

Standard

Standard

Standard

Standard

Standard

Connection to centralized control

Standard

Standard

Standard

Standard

Standard

Compressor / Error, Fan output

Installation box / Mounting plate for adaptor PCBs For units where there is no space in the switchbox

Decoration panel (obligatory for cassette units, optional for others, rear panel for FXLQ)

Others

2-way blow

Simplified wired remote controller External wired temperature sensor

FXFQ 20~125 with autocleaning

✓ ✓

BRC2C51 Infra-red remote controller including receiver

4-way (600x600)

BYCQ140C(W)

BYCQ140CG

BYFQ60B

BYBC32G

BYBC50G

Kit for mounting of decoration panel direct onto unit

-

-

-

-

-

Panel spacer for reducing required installation height

-

-

KDBQ44B60

-

-

KDBHQ55C140

KDBHQ55C140

KDBH44BA60

-

-

CE.KDDQ55C140

-

KDDQ44XA60

-

-

-

-

-

-

-

Sealing kit for 3-directional or 2-directional air discharge Fresh air intake kit Air discharge adaptor for round duct Replacement long life filter Drain pump kit

KAFP551K160

-

-

-

-

Standard

Standard

Standard

Standard

Standard

Concealed ceiling units (duct units) High ESP BRC1E51A Premium wired remote controller with full-text interface and back-light BRC1D52 Standard wired remote controller with weekly timer BRC2C51

Adaptors and Control

Simplified wired remote controller

FXMQ 40

FXMQ 50~80

FXMQ 100~125

FXMQ 200~250

✓ ✓ ✓

✓ ✓ ✓

✓ ✓ ✓

✓ ✓ ✓

✓ ✓ ✓

Infra-red remote controller including receiver

BRC4C65

BRC4C65

BRC4C65

BRC4C65

BRC4C65

External wired temperature sensor

KRCS01-4

KRCS01-4

KRCS01-4

KRCS01-4

KRCS01-1

External wireless temperature sensor

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

Wiring adaptor for external monitoring/control via dry contacts and setpoint control via 0-140Ω

KRP4A51

KRP4A51

KRP4A51

KRP4A51

KRP4A51

Wiring adaptor for external central monitoring/control (controls 1 entire system)

KRP2A51

KRP2A51

KRP2A51

KRP2A51

KRP2A51

Wiring adaptor with 4 output signals

EKRP1B2

EKRP1B2

EKRP1B2

EKRP1B2

KRP1B61

-

-

-

-

-

Adaptor for multi-tenant applications (24VAC PCB power supply interface)

DTA114A61

DTA114A61

DTA114A61

DTA114A61

-

External control adaptor for outdoor unit

DTA104A61

DTA104A61

DTA104A61

DTA104A61

DTA104A61

KRP4A96

KRP4A96

KRP4A96

KRP4A96

-

Connector for forced-off contact

Standard

Standard

Standard

Standard

Standard

Connection to centralized control

Standard

Standard

Standard

Standard

Standard

Compressor / Error, Fan, Aux. heater, Humidifier output Wiring adaptor with 2 output signals Compressor / Error, Fan output

Installation box / Mounting plate for adaptor PCBs For units where there is no space in the switchbox

Others

Large

FXMQ 20~32

Decoration panel (obligatory for cassette units, optional for others, rear panel for FXLQ)

BYBS32D

BYBS45D

BYBS71D

BYBS125D

-

Kit for mounting of decoration panel direct onto unit

EKBYBSD

EKBYBSD

EKBYBSD

EKBYBSD

-

Panel spacer for reducing required installation height

-

-

-

-

-

Sealing kit for 3-directional or 2-directional air discharge

-

-

-

-

-

Fresh air intake kit

-

-

-

-

-

KDAJ25K36A

KDAJ25K56

KDAJ25K71

KDAJ25K140

-

Air discharge adaptor for round duct Replacement long life filter Drain pump kit

122

-

-

-

-

-

Standard

Standard

Standard

Standard

-


Ceiling mounted cassette units 2-way blow

Concealed ceiling units (duct units)

Corner (1-way blow)

Small

Slim

Standard

FXCQ 63

FXKQ 25~40

FXKQ 63

FXDQ 20~25 M9

FXDQ 15~63 P7

FXSQ 20~32

FXSQ 40~50

FXSQ 63~80

FXSQ 100~140

✓ ✓

✓ ✓

✓ ✓

-

-

-

✓ ✓ ✓

✓ ✓ ✓

✓ ✓ ✓

✓ ✓ ✓

✓ ✓ ✓

✓ ✓ ✓

BRC7C62

BRC4C61

BRC4C61

BRC4C62

BRC4C65

BRC4C65

BRC4C65

BRC4C65

BRC4C65

KRCS01-1

KRCS01-1

KRCS01-1

KRCS01-1

KRCS01-1

KRCS01-4

KRCS01-4

KRCS01-4

KRCS01-4

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

KRP4A51

KRP4A51

KRP4A51

KRP4A51

KRP4A54

KRP4A51

KRP4A51

KRP4A51

KRP4A51

KRP2A51

KRP2A51

KRP2A51

KRP2A51

KRP2A61

KRP2A61

KRP2A51

KRP2A51

KRP2A51

EKRP1B2

KRP1B61

KRP1B61

EKRP1B2

-

EKRP1B2

EKRP1B2

EKRP1B2

EKRP1B2

-

-

-

-

KRP1B56

-

-

-

-

-

-

-

EKMTAC

EKMTAC

DTA114A61

DTA114A61

DTA114A61

DTA114A61

DTA104A61

DTA104A61

DTA104A61

DTA104A61

DTA104A53

DTA104A61

DTA104A61

DTA104A61

DTA104A61

KRP1B96

-

-

-

KRP1BA101

KRP4A96

KRP4A96

KRP4A96

KRP4A96

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

Standard

BYBC63G

BYK45F

BYK71F

-

-

BYBS32D

BYBS45D

BYBS71D

BYBS125D

-

-

-

-

-

EKBYBSD

EKBYBSD

EKBYBSD

EKBYBSD

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

KDAJ25K36A

KDAJ25K56

KDAJ25K71

KDAJ25K140

-

-

-

-

-

-

-

-

-

Standard

Standard

Standard

-KDAJ25K56

Standard

Standard

Standard

Standard

Standard

Ceiling suspended units 1-way blow

Wall mounted units 4-way blow

Floor standing units Concealed

Free-standing

FXHQ 32

FXHQ 63~100

FXUQ 71

FXUQ 100~125

FXAQ 15~63

FXNQ 20~63

FXLQ 20~25

FXLQ 32~40

FXLQ 50~63

✓ ✓

✓ ✓

✓ ✓

✓ ✓

✓ ✓

-

-

-

-

-

✓ ✓ ✓

✓ ✓ ✓

✓ ✓ ✓

✓ ✓ ✓

BRC7E63

BRC7E63

BRC7C528

BRC7C528

BRC7E618

BRC4C65

BRC4C65

BRC4C65

BRC4C65

KRCS01-1

KRCS01-1

KRCS01-1

KRCS01-1

KRCS01-1

KRCS01-1

KRCS01-1

KRCS01-1

KRCS01-1

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

K.RSS

KRP4A52

KRP4A52

KRP4A53

KRP4A53

KRP4A51

KRP4A51

KRP4A51

KRP4A51

KRP4A51

KRP2A52

KRP2A52

-

-

KRP2A51

KRP2A51

KRP2A51

KRP2A51

KRP2A51

KRP1B3

KRP1B3

-

-

-

KRP1B61

KRP1B61

KRP1B61

KRP1B61

-

-

-

-

-

-

-

-

-

DTA114A61

DTA114A61

-

-

DTA114A61

EKMTAC

EKMTAC

EKMTAC

EKMTAC

DTA104A62

DTA104A62

-

-

DTA104A61

-

-

-

-

KRP1C93

KRP1C93

KRP1B97

KRP1B97

KRP4A93

-

-

-

-

Standard

Standard

EKRORO

EKRORO

Standard

Standard

Standard

Standard

Standard

Standard

Standard

DTA102A52

DTA102A52

Standard

Standard

Standard

Standard

Standard

-

-

-

-

-

-

EKRDP25

EKRDP40

EKRDP63

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

KDU50M60

KDU50M125

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

KDU50M60

KDU50M125

Standard

Standard

K-KDU572EVE

-

-

-

-

123


Ventilation Refrigerant Distribution

Options & accessories -

Heat Reclaim Ventilation

100% freshair unit

With DX coil VAM 150~2000 BRC1E51A Premium wired remote controller with full-text interface and back-light BRC1D52 Standard wired remote controller with weekly timer BRC301B61 Wired remote controller for HRV

Adaptors and Control

BRP4A50 Control kit for auxiliary 3rd party heater KRP50-2 Adaptor PCB for 3rd party humidifier control / for operation signal output External wired temperature sensor Wiring adaptor for external monitoring/control via dry contacts and setpoint control via 0-140Ω Wiring adaptor for external central monitoring/ control (controls 1 entire system)

✓ ✓ ✓ ✓ ✓

Biddle air curtains

AHU application control boxes

For VRV

For ERQ

For VRV

For ERQ

CYV-DK-

CYQ-DK-

EKEQMCB

EKEQDCB

EKEQFCB

VKM 50

VKM 80~100

FXMQ 125~250 MF

✓ ✓

✓ ✓

✓ ✓

✓ ✓

✓ ✓

✓ ✓

✓ ✓

✓ ✓

-

-

-

-

-

-

-

-

✓ ✓

✓ ✓

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

KRCS01-1

KRCS01-1

-

-

-

-

KRP4A51

-

-

KRP4A51

KRP4A51

-

KRP2A61

KRP2A61

KRP2A61

KRP2A61

-

-

-

-

-

-

-

-

KRP1B61

-

-

-

-

-

-

-

-

DTA104A61

-

-

DTA104A61

DTA104A61

Ask your Daikin representative

Wiring adaptor with 4 output signals Compressor / Error, Fan, Aux. heater, Humidifier output External control adaptor for outdoor unit Allows to activate Low Noise Operation and three levels of Demand Limiting via external dry contacts. Installation box / Mounting plate for adaptor PCBs

KRP1B93

KRP1B93

KRP1B93

-

-

-

-

-

-

Standard

Standard

Standard

Standard

Standard

-

-

-

-

Silencer for 250 mm round duct

-

-

KDDM24B100

-

-

-

-

-

-

Drain pump kit

-

-

-

-

-

-

-

-

-

For units where there is no space in the switchbox

Others

Connection to centralized control

Refnet Joints

Heat Pump systems (2-pipe)

Heat Recovery systems (3-pipe)

Metric-size connections Imperial-size connections Sound reduction kit (sound insulation) Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the A-B-C terminals of the outdoor unit / BS-box. Installation box for remote cool/heat selector KRC19-26

Metric-size connections

Imperial-size connections

Refnet Headers

Capacity index < 201

Capacity index 201~290

Capacity index 291~640

Capacity index > 640

Capacity index < 291

Capacity index 291~640

Capacity index > 640

KHRQM23M20T

KHRQM23M29T

KHRQM23M64T

KHRQM23M75T

KHRQM23M29H

KHRQM23M64H

KHRQM23M75H

KHRQ23M20T

KHRQ23M29T9

KHRQ23M64T

KHRQ23M75T

KHRQ23M29H

KHRQ23M64H

KHRQ23M75H

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

KHRQM22M20T

KHRQM22M29T

KHRQM22M64T

KHRQM22M75T

KHRQM22M29H

KHRQM22M64H

KHRQM22M75H

KHRQ22M20T

KHRQ22M29T9

KHRQ22M64T

KHRQ22M75T

KHRQ22M29H

KHRQ22M64H

KHRQ22M75H

124


Hot water heating unit for VRV

Inverter Heat Pump Condensing Units

HXHD125A EKRP1HBAA

ERQ 125 AW1

ERQ 200~250 AW1

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

✓ ✓

✓ ✓

✓ ✓

-

KWC26B160

KWC26B280

✓ ✓ ✓ ✓ ✓ ✓

Digital I/O PCB EKRP1AHTA Demand PCB - Required to install to be able to connect Room thermostat EKRUAHTB

Adaptors and Control

ERQ 100~140 AV1

Remote user interface [remocon] - Same controller as supplied with Cascade unit can be mounted parallel or on other location. If 2 controllers are installed, the installer needs to select 1 master & 1 slave EKRTWA Wired Room thermostat - Requires Demand PCB EKRP1AHTA EKRTR1 Wireless Room thermostat - Requires Demand PCB EKRP1AHTA EKRTETS Remote sensor for Room thermostat - Requires Demand PCB EKRP1AHTA KRC19-26 Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the A-B-C terminals of the outdoor unit / BS-box.

-

KJB111A

-

Installation box for remote cool/heat selector KRC19-26

Others

Central drain pan kit

Installs onto the underside of the outdoor unit and collects drain water from all bottom plate outlets into a single outlet. In cold areas should be heated by a field-supplied heater to prevent drain water from freezing in the drain pan.

-

Heat Recovery Branch Selector Boxes (BS-Boxes) 1-port Capacity index < 101

1-port Capacity index 101 ~ 160

1-port Capacity index 161 ~ 250

4-port Capacity index < 100 per port

6-port Capacity index < 100 per port

2-port For Split and SkyAir indoor units

External Expansion Valve Boxes (BP- / BEV- boxes) 3-port For Split and 1-port 1-port SkyAir indoor For FXUQ 71 For FXUQ 100 units

1-port For FXUQ 125

-

-

-

-

-

-

-

-

-

-

BSVQ100P8B

BSVQ160P8B

BSVQ250P8B

BSV4Q100PV

BSV6Q100PV

-

-

BEVQ71MA

BEVQ100MA

BEVQ125MA

EKBSVQLNP

EKBSVQLNP

EKBSVQLNP

-

-

-

-

-

-

-

-

-

-

-

-

KRC19-26

KRC19-26

1 kit per port necessary

1 kit per port necessary

KRC19-26

KRC19-26

KRC19-26

KJB111A

KJB111A

KJB111A

KJB111A

KJB111A

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

BPMKS967A2

BPMKS967A3

BEVQ71MA

BEVQ100MA

BEVQ125MA

125


MEASURING CONDITIONS AIR CONDITIONING 1) nominal cooling capacities are based on: Indoor temperature Outdoor temperature Refrigerant piping length Level difference 2) nominal heating capacities are based on: Indoor temperature Outdoor temperature Refrigerant piping length Level difference

27°CDB/19°CWB 35°CDB 7.5m - 8/5m VRV 0m 20°CDB 7°CDB/6°CWB 7.5m - 8/5m VRV 0m

The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment (for measuring conditions: please refer to the technical databooks). The sound power level is an absolute value indicating the “power” which a sound source generates. For more detailed information please consult our technical databooks.

126


® VRV

Catalogue ■

DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH campus 21, Europaring F12/402, A – 2345 Brunn/Gebirge Tel.: +43 / 22 36 / 3 25 57-0, Fax: +43 / 22 36 / 3 25 57-900 e-mail: office@daikin.at, www.daikin-ce.com

The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V./Daikin Central Europe HandelsGmbH. Daikin Europe N.V./Daikin Central Europe HandelsGmbH has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V./Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

Daikin products are distributed by:

ECPEN12_02_dace_VRV • Copyright Daikin We reserve the right for printing errors and model changes.

V R V ® C ATA LO G U E 2 012

Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.

ALL SEASONS PERFECT C MFORT

2012