® VRV
Catalogue ■
DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH campus 21, Europaring F12/402, A – 2345 Brunn/Gebirge Tel.: +43 / 22 36 / 3 25 57-0, Fax: +43 / 22 36 / 3 25 57-900 e-mail: office@daikin.at, www.daikin-ce.com
The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V./Daikin Central Europe HandelsGmbH. Daikin Europe N.V./Daikin Central Europe HandelsGmbH has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V./Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
Daikin products are distributed by:
ECPEN12_02_dace_VRV • Copyright Daikin We reserve the right for printing errors and model changes.
V R V ® C ATA LO G U E 2 012
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.
ALL SEASONS PERFECT C MFORT
2012
BENEFITS FOR
building OWNERS With Daikin’s proprietary inverter technology and cutting-edge control technology for refrigerant, the VRV®III air conditioning system operates with outstanding efficiency. This contributes to high energy savings, which GREATLY REDUCES facilitates better building management.
YOUR RUNNING COSTS
and
CONSULTANT and DESIGN OFFICES Benefits for
Daikin’s VRV® systems include indoor and outdoor units available in a wide range of models for various building sizes and installation conditions. Long refrigerant piping lengths and other features put few restrictions on design for GREAT building.
Benefits for
FLEXIBILITY in meeting needs of the
INSTALLERS Daikin offers a compact design for VRV® outdoor units by further optimising equipment functions, exceeding the norm for air conditioning systems. Compact units
FACILITATE
INSTALLATION in limited areas, such as rooftops, and take up less effective space. Easier installation work realises FAST COMPLETION with time to spare.
Benefits for
END USERS To provide a COMFORTABLE AIR ENVIRONMENT , Daikin offers air treatment systems beyond mere air conditioning. As well as bringing air to a comfortable temperature, the air quality can be improved with ventilation, humidification, and other processes.
EASE OF USE is realised through advanced, centralised control systems.
TABLE OF CONTENTS The next generation VRV ... About Daikin What’s new Daikin VRV® history The Total Solution concept Which VRV® system is the best for you?
4 6 8 10 12 14
Unit overviews Outdoor units Indoor units Ventilation units Biddle air curtains Hydroboxes Control solutions Selection programs
16 18 20 21 21 21 22
LARGE COMMERCIAL APPLICATIONS VRV OUTDOOR SYSTEMS Introduction & Benefits Benefits for building owners Benefits for design offices and consultants Benefits for installers Benefits for end users Advanced VRV technologies
NEW
24 25 28 30 33 35
Heat recovery systems REYAQ-P REYQ-P8/P9 / REYHQ-P9
38 42
Heat pump systems RXYQ-P9 / RXYHQ-P9 RTSYQ-P RXYRQ-P RXYSQ-P8
46 50 54 56
Replacement VRV RQCEQ-P / RQYQ-P
58
Water-cooled VRV RWEYQ-P / RWEYQ-PR
62
Branch selector boxes (BS-boxes) BSVQ-P8 BSV4Q-PV / BSV6Q-PV
67 67
2
VRV INDOOR UNITS Ceiling mounted cassettes Auto cleaning decoration panel FXFQ-P9 FXZQ-M9 FXCQ-M8 FXKQ-MA Ceiling suspended units FXUQ-MA FXHQ-MA
NEW
Wall mounted units FXAQ-P
68 NEW
70 71 72 73 74
NEW
75 76
77
Concealed ceiling units (Duct units) FXDQ-M9 FXDQ-P7 FXSQ-P / FXMQ-P7 FXMQ-MA
78 79 80 82
Floor standing units FXNQ-P FXLQ-P
83 84
Hot water units HXHD-A Hot water unit accessories
85 86
VENTILATION Heat reclaim ventilation VAM-FA VKM-G(M)
89 90
Outdoor air processing unit FXMQ-MF
91
VRV air handling applications EKEQMCB Plug&Play VRV connection AHU
92 93
Heat pump inverter condensing units ERQ 102
NEW
Biddle air curtains CYQ-DK- CYV-DK-
104 105
CONTROLS, OPTIONS & ACCESSORIES NEW
CONTROL SYSTEMS Individual control systems BRC1E- Overview of other individual controls
107 108
Centralized control systems Overview of basic central controls 109 DCS601C51 Intelligent Touch Controller 110 DAM602B51/52 Intelligent Manager 111
NEW NEW
Advanced individual unit control & interfaces RTD- Universal control adaptors DTA113B51 DS-Net adaptor KKRP01A Online Controller
NEW
Standard protocol interfaces KLIC-DI / -DD KNX protocol RTD-NET Modbus protocol DMS502A51 BACnet protocol DMS504B51 LonTalk protocol
NEW
OPTIONS & ACCESSORIES Notable accessories K.RSS Wireless temperature sensor 118 KRCS01-1 / -4 Wired temperature sensor 118 Other integration devices 119
NEW
Options & Accessories overview pages VRV outdoor units VRV indoor units Ventilation units Refrigerant distribution
112 113 114
3
116 116 117 117
120 122 124 124
The next generation VRV …
PR
EL I
M
IN AR Y
Available 2nd half 2012
VRV IV Heat Pump & Heat Recovery* ›› Personalize your VRV to achieve highest possible seasonal efficiency and comfort with advanced evaporating & condensing temperature control ›› Perfect heating comfort: continuous heating during defrost (also on Heat Pump) ›› USB commissioning
New round flow cassette* ›› The optional presence sensor adjusts set point or switches off the unit when nobody is in the room saving up to 27% of energy ›› The optional presence sensor directs air flow away from people to avoid draught ›› Save up to 50% of energy thanks to daily filter cleaning with optional auto cleaning panel (Wolverhampton, UK test site) ›› The flexibility to adapt the air flow pattern to a changed interior *preliminary
4
VRV Heat Pump - RYCQ-A* AR Y
›› For smaller projects, with standard cooling & heating requirements
IN
›› Connectable to all VRV indoor units, controls and ventilation
IM
›› Total piping length: 300m
EL
›› Maximum piping length: 165m
PR
›› Range: 8 - 20HP
* ›› Contemporary design
›› Modbus
›› User friendly interface
›› Manage up to 2,560 groups of indoor units
›› Increased flexibility
›› Energy management tools help to prevent energy waste
›› USB connection
›› Remote refrigerant containment check on VRV
›› Better acceptance of DX technology to condition fresh air ›› Easier integration of ERQ in a total HVAC solution via new Intelligent Touch Manager *preliminary
5
PR
›› Perfect comfort thanks to continuous heating during defrost
EL IM
IN
AR Y
New ERQ*
Daikin Europe N.V.
ABOUT DAIKIN Daikin has a worldwide reputation based on 85 years’ experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use.
Daikin quality Daikin’s much envied quality quite simply stems from the close attention paid to design, production and testing as well as aftersales support. To this end, every component is carefully selected and rigorously tested to verify its contribution to product quality and reliability.
TOTAL CLIMATE CONTROL: Setting new standards Total climate control in which perfect living and working conditions are delivered inside a building is now both achievable and economically viable using the Daikin VRV® system. At the heart of the VRV® climate control system is our renowned, cutting-edge heat pump technology that delivers very high levels of energy efficiency by using renewable energy from the outdoor air to drive the heating and cooling process. Without the need for a secondary heating system, this technology delivers high output for low input, leading to a direct saving in CO2 emissions and running costs. But the Daikin VRV® goes further and uses the same advanced technology to extract heat from areas needing cooling and then reuses it to warm other areas or create hot water, thus enabling it to heat and cool different parts of the building at the same time. This combination of technologies means that our system regularly delivers a Coefficient of Performance (COP) of 4 or more, meaning that it produces four units of heat energy for every one unit of electrical energy used. And, when operating in heat recovery mode, the COP can be has high as 10, making the Daikin VRV® system the most advanced of its kind. 6
BE YOND THE ORDINARY To achieve perfect indoor conditions means delivering the optimal comfort levels from the perspective of the occupants by ensuring the right temperature in the right places, with the right level of fresh air and humidity, and all with an acceptable level of sound. It also means delivering attention to detail in all aspects of the technical configuration. Daikin’s approach is a total engineered solution that focuses not only on the core components but also on the equipment that can be connected to our new generation of VRVŽ systems. Our latest equipment is designed to optimise the performance of the total system by automating as much of the routine controls and checks as possible and by providing a global network of local engineers to help maintain top efficiency.
Energy efficiency, more then COP Some of the areas on which we focus include indoor units that have an automatic filter cleaning function to maintain optimum airflow and reduce energy consumption, while our concealed ceiling units have inverter driven fans that automatically adjust the airflow. Similarly, our automatic charging and containment check ensures the right levels of refrigerant, again ensuring the highest possible efficiency. And then there is the matter of control system. Here we have created a user-friendly integrated control unit that regulates just about everything and even takes the weather into account to ensure that the inside conditions are optimised no matter what the outside conditions. Indeed, the Daikin total climate control solution is beyond the ordinary.
This sign highlights features where Daikin has invested into technologies to reduce the impact of air conditioning on the environment.
7
what's new? TOTAL SOLUTION VRV
p. 38
›› A VRV system covering all of your cooling and heating needs ›› Produce hot water virtually for free thanks to heat recovery in cooling Total COP’s approaching 9 in simultaneous cooling-heating operation 80°C hot water with pure heat pump technology - without any direct electrical heating All hydraulic equipment included for simple Plug&Play installation
45°C - 75°C
OR EKHWP 45°C - 75°C
EKHTS
25°C - 45°C
25°C - 75°C
REYAQ-P
HXHD125A
High sensible option on VRV®III heat pump
p. 33, 46
›› Optimise the working of the units for the European climate. ›› Work with increased sensible capacity in cooling mode, resulting in higher efficiency and improved comfort. Higher comfort to the end user Preventing cold draughts thanks to higher discharge air temperature on the indoor unit. Higher energy efficiency As no energy is wasted on unnecessary dehumidification, the system will work more efficiently while in cooling mode.
›› The best seasonal performance and the lowest running cost in the industry ›› All standard VRV®III features 8
VRV®III heat pump, with connection to stylish indoor units
p. 54
›› Innovative VRV® technology combined with stylish and silent indoor units ›› Wide range of indoor units: combine VRV® indoor units and stylish indoor units such as Daikin Emura and Nexura in one system ›› Up to 39 indoor units can be connected to a single 18HP unit
p. 56
VRV®III-S heat pump ›› ›› ›› ››
Slim design for flexible installation Wide range of indoor units: either connect VRV® or stylish indoor units such as Daikin Emura, Nexura … Up to 9 indoor units can be connected All indoor units can be individually controlled
FTXG-J
FVXS-F
BPMKS967B3
FBQ-C FTXS-G BPMKS967B2
FCQ-C8
FTXG-J FVXG-K BPMKS967B2
1.5 kW indoor units
p. 72, 77, 79
›› Units especially developed for small or well-insulated rooms, such as hotel bedrooms or small offices. ›› Available as 4-way blow cassette (FXZQ) and concealed ceiling unit (FXDQ-P7) . Wall mounted (FXAQ-P) unit will become available in the second half of 2012.
9
over 25 years of VRV ® History In anticipation of
The introduction
phase out dates
of the VRV®II-S series extends
for all CFC based
VRV® operating scope into
equipment, Daikin
the light commercial
Europe steps up the
sectors. Available in 4, 5 and
production of VRV
6HP capacities, the system is
air conditioning
designed for installation in up
units using R-407C.
to 9 rooms.
®
The original VRV® air conditioning system developed by Daikin
Daikin Europe celebrates its
Industries Ltd. in 1982 is introduced into Europe in VRV® standard format. VRV® D series can supply conditioned air from up to 6 indoor units connected to a single outdoor unit.
25th anniversary with the award of an ISO14001 environmental certificate and the introduction of VRV® Inverter series with R-407C, in cooling only or heat pump format. As many as 16 indoor units can be connected to 1 single outdoor unit.
1987
1991
1994
1998
2003
2004
A further step forward
Daikin introduces the VRV®II, the
is taken in 1991 with the
world’s first R-410A operated variable
introduction of the
refrigerant flow system. Available in
VRV® heat recovery system,
cooling only, heat pump and heat
offering simultaneous cooling
recovery versions, the system, which
and heating from different
represents a considerable advance
indoor units on the same
over earlier VRV® systems, demonstrates
refrigeration circuit.
Consistent high quality and efficiency lead to the widespread acceptance of the VRV® concept and Daikin becomes the first Japanese air conditioning manufacturer to be awarded the ISO9001 certification. Daikin applies yet another quantum leap to VRV® technology: the VRV® Inverter-H series, operate up to 16 indoor units from just 1 outdoor unit.
10
Daikin’s innovative application of new technology. No less than 40 indoor units in heat recovery as well as heat pump format can be connected to a single refrigerant circuit.
Daikin has extended the
Daikin has extended its VRV® range with the innovative replacement
operational scope of its acclaimed
VRV® – a highly cost effective replacement for VRV® systems still
VRV®II inverter driven dx air
operating on the banned R-22 refrigerant. This cost effective upgrade is
conditioning system, with a new
possible because VRV®III-Q outdoor units can be installed using existing
water cooled version,
piping and in some cases existing indoor units. The system, among
VRV -WII. Available in 10, 20 and
the first of its type, comes in heat pump and heat recovery models
30HP models, the system operates
with capacities between 5 and 30HP and offers drastically increased
on R-410A refrigerant and is
efficiencies and considerable reductions in energy consumption
available in both heat pump and
compared to R-22 systems.
®
heat recovery versions.
2005
2006-2007
2008
2009
2010
Daikin has announced the third
Daikin introduces a new heat
generation of its much acclaimed
pump range optimised for
VRV range with the extensively
heating (VRV®III-C). This new range
re engineered VRV®III. Available
has an extended operation
in heat recovery, heat pump
range down
and cooling versions, VRV®III
to -25°C and has a greatly
incorporates all the best features
improved COP in low ambient
Daikin has extended the VRV®III
of earlier VRV® systems. However,
temperatures, with the newly
range with the re-engineered
it also possesses a considerable
developed 2-stage compressor
water cooled VRV®-WIII, which is
number of new design, installation
system.
available in 9 different outdoor
®
and maintenance refinements as
combinations from 8 to 30HP.
automatic charging
A geothermal version is also
and testing.
available now.
Up to 64 indoor untis
This system uses geothermal heat
can be connected to
as a renewable energy source
one system.
and can operate down to -10°C in heating mode.
11
Total Solution Concept The Daikin VRV® Total Solution provides a single point of contact for the design and maintenance of your integrated climate control system. Our modular units enable you to select the right mix of equipment and technology to ensure that you achieve the optimal balance of temperature, humidity and air freshness for the perfect comfort zone with maximum energy efficiency and cost effectiveness.
VRV® OUTDOOR UNITS Integrated heat pump solution ›› ›› ››
Solution for every climate from -25°C to +50°C Flexible to fit any building Top efficiencies to ensure low running costs and CO2 emissions
HEATING AND COOLING
USER FRIENDLY CONTROL SYSTEMS
22
Wide range of indoor units that fit rooms of any size and shape
Full control for maximum efficiency
›› ›› ›› ››
›› From individual control to the management of multiple buildings ›› User friendly touch screen control ›› Remote control & monitoring via internet
Perfect comfort Whisper-quiet operation Stylish design Concealed installation possible
+
Save up to 15% compared to traditional systems
12
Cooling 22
Extracted heat 22
Heating
VRV® heat recovery system
Hot Water
Ventilation
Air Curtain
AIR SEPARATION THROUGH AIR CURTAINS
VENTILATION
HOT WATER
A highly efficient solution to doorway climate separation
Create a high-quality indoor environment
Use heat pump technology to produce hot water
›› Most efficient open-door solution ›› Year-round comfort, even on the most demanding days ›› Free air curtain heating possible
›› Heat is reclaimed between out and indoor air ›› Free cooling possible ›› Optimum control of humidity ›› For one room or your entire building
›› Free hot water production possible ›› Possibility to connect to solar panels ›› Possible applications: bathrooms, sinks, under floor heating and radiators ›› Hot water up to 80°C
+
Save up to 72% compared to an electric air curtain
+
Save up to 40% thanks to lower cooling and heating requirements
13
+
Save up to 17% compared to a gas boiler
Which VRV ® outdoor system offers me the best solution? Air cooled outdoor systems Heat Recovery
›› For simultaneous heating and cooling from one system ›› Heat exhausted from indoor units in the cooling cycle is merely transferred to units in areas requiring heat, maximising energy efficiency, reducing electricity costs and leading to high partload efficiencies (up to 91). ›› Operation range in cooling down to -20°C (technical cooling)
Standard series optimised solutions Small footprint combination ›› Optimized footprint within heat recovery range
1
Heat Pump
REYQ8P8 50% cooling – 50% heating load. Conditions: outdoor temperature 11°CDB, indoor temperature 18°CWB, 22°CDB.
›› For either heating or cooling operation from one system
Standard series optimised solutions Small footprint combination ›› Optimized footprint within heat pump range
High COP combination ›› Top energy efficiency in Daikin heat pump range
VRV® Heat Pump with connection to stylish indoor units ›› Innovative VRV® technology combined with stylish and silent indoor units
VRV ® Heat Pump optimised for heating ›› First system in the industry developed for heating operation at low ambient conditions. ›› Extended operation range for heating down to -25°C ›› Stable heating capacity and high efficiencies at low ambient temperatures (COP > 3 at -10°C outdoor temperature)
VRV ®III-S Heat Pump ›› Especially designed for small capacities ›› Space saving design ›› Either connect VRV® or stylish indoor units: Daikin Emura, Nexura…
Replacement
VRV® heat recovery, with connection to heating only hydrobox ›› Fully integrated system ›› Free hot water High COP combination ›› Top energy efficiency in Daikin heat recovery range
›› For cost-effective upgrade from R-22/R-407C to R-410A ›› Increased energy efficiency compared to R-22/R-407C systems ›› Fast installation compared to total system replacement (re-use of existing piping and in some cases indoor units) ›› Available in heat recovery and heat pump 14
Water cooled outdoor systems ›› Allows heat recovery within the total building, thanks to the storage of energy in the water circuit. ›› Compact design and stacked configuration possible. ›› Suitable for multi-storey and large buildings because of the hardly unlimited possibilities of water piping.
Heat Recovery
Standard series Geothermal series ›› For simultaneous heating and cooling from one refrigerant system
Heat Pump
›› No need for an external heating or cooling source ›› Heating with ground sourced water as a renewable energy source ›› Extension of the operation range of inlet water temperature down to -10°C in heating mode
Standard series Geothermal series ›› For either heating or cooling operation from one refrigerant system
15
›› No need for an external heating or cooling source ›› Heating with ground sourced water as a renewable energy source ›› Extension of the operation range of inlet water temperature down to -10°C in heating mode
overview outdoor unit range System
4
5
6
8
10
12
14
16
18
20
22
1
Type
Product name
Cooling capacity (kW)
11.2
14.0
15.5
22.4
28.0
33.5
40.0
45.0
49.0
55.9
61.5
Heating capacity (kW)2
12.5
16.0
18.0
25.0
31.5
37.5
45.0
50.0
56.5
62.5
69.0
Cooling capacity (kW)3
22.4
26.7
44.8
49.1
53.4
Heating capacity (kW)4
25.0
31.5
50.0
56.5
63.0
10
12
REYAQ-P
NEW ››› HEAT RECOVERY
for connection with heating only hydrobox REYHQ-P High COP combination
REYQ-P8/P9 Small footprint combination
RXYHQ-P9 High COP combination
AIR COOLED
NEW ›››
RXYQ-P9 Small footprint combination
HEAT PUMP
NEW ›››
RTSYQ-P Heat pump optimised for heating
NEW ›››
RXYRQ-P Heat pump with connection to stylish indoor units
RXYSQ-P8Y1 (Three phase)
H/R - H/P
SERIES
STANDARD GEOTHERMAL
System
H/R - H/P
NEW ›››
SERIES
RXYSQ-P8V1 (Single phase)
WATER COOLED
NEW ›››
Type
RWEYQ-P
RWEYQ-PR
Product name
4
5
8
13
14
16
18
20
22
500
540
636
280
Cooling capacity (kW)1 HR/HP
-/14.0
-/22.4 28.0/28.0 -/33.5
36.0/-
-/40.0
50.0/50.4 54.0/55.9 63.6/61.
Heating capacity (kW)2 HR/HP
-/16.0
-/25.0
40.0/-
-/45.0
52.0/50.0 56.0/56.5 60.0/62.5 67.2/69.
1 2 3 4
-/37.5
RQCEQ-P HEAT PUMP
HEAT RECOVERY -
Q REPLACEMENT VRV®
AIR COOLED
NEW ›››
32.0/31.5
360
460
140
Capacity class
VRV®III-Q - H/R
Q RQYQ-P VRV®III-Q - H/P
Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, inlet water temperature : 30°C, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal cooling capacities are based on: indoor temperature : 27°CDB, 19°CWB, inlet water temperature : 30°C, equivalent refrigerant piping : 7.5m, level difference : 0m Nominal heating capacities are based on: indoor temperature : 20°CDB, inlet water temperature : 20°C, equivalent refrigerant piping : 7.5m, level difference : 0m
16
22
Capacity (HP) 42
44
46
48
50
52
54
116.0
120.0
126.0
132.0
138.0
143.0
147.0
75.0
81.5
88.0
94.0
102.0
107.0
113.0
119.0
126.0
132.0
138.0
145.0
151.0
158.0
163.0
170.0
67.2
71.5
75.8
80.1
75.0
81.5
88.0
94.5
Indoor Air Hydrobox Ventilation units curtain connection
+ x + + +
+
+
+ +
+
+ x + + +
+
x
+ +
+
+ x + + +
+
x
+ +
+
+ x + + +
+
x
+ +
+
+ x + + +
+
x
+ +
+
+ x + + +
+
x
+ +
+
+ + + x x
x
x
+ +
+
+ • + x +
+
x
+ +
+
+ • + x +
+
x
+ +
+
+ x + + +
+
x
+ +
+
+ x + + +
+
x
+ +
+
26
28
30
712
744
816
848
32
34
36
38
40
42
44
46
48
.5 71.2/67.0 74.4/73.0 81.6/78.5 84.4/85.0 -/90.0
-/96.0
-/101.0
-/107.0
-/112.0
-/118.0
-/124.0
-/130.0
-/135.0
.0 78.4/75.0 80.8/81.5 87.2/87.5 89.6/95.0 -/100.0
-/108.0
-/113.0
-/119.0
-/125.0
-/132.0
-/138.0
-/145.0
-/150.0
50
52
54
+ • x 5 6
17
VRV® type indoor units (such as FXSQ)
Capacity (HP) 24
Control systems
Network solutions (such as DCS6*/DAM/DMS 6)
40 111.0
Individual control (such as BRC 6)
38 105.0
Centralised control (such as DCS3*/DST 6)
36 98.0
Heating only HT hydrobox
34 94.0
Comfort air curtain (CAVS)
32 89.0
AHU connection kit (such as EKEXV)
30 82.5
Heat Reclaim ventilation (such as VAM)
28 77.0
Fresh air indoor units (such as FXMQ-MF)
26 71.4
Residential type indoor units (such as Daikin Emura) 5
24 67.0
BP-box required Exact control possibilities depend on the selected system components All + components can be connected together to 1 system Can be connected, but not in combination with other components Can not be connected
overview indoor unit range VRV® air conditioning brings summer freshness and winter warmth to offices, hotels, department stores and many other commercial premises. It enhances the indoor environment and creates a basis for increased business prosperity and whatever the air conditioning requirement, a Daikin indoor unit will provide the answer. VRV® air conditioning can be supplied via 26 different indoor unit models in a total of 116 variations. The Roundflow cassette now includes a self cleaning filter, which automatically cleans itself daily, leading to yearly energy savings of up to 10%. Dust from the filter is collected in the unit for removal by simple vacuum cleaning.
Capacity Type
Model
Product name
15
20
25
32
40
50
63
71
Cooling capacity (kW)1
1.7
2.2
2.8
3.6
4.5
5.6
7.1
Heating capacity (kW)2
1.9
2.5
3.2
4.0
5.0
6.3
8.0
CEILING MOUNTED CASSETTE
Round flow cassette
NEW ›››
autocleaning function possible
80
100
125
140
200
250
8.0
9.0
11.2
14.0
16.0
22.4
28.0
9.0
10.0
12.5
16.0
18.0
25.0
31.5
FXFQ-P9
4-way blow ceiling mounted cassette
FXZQ-M9
2-way blow ceiling mounted cassette
FXCQ-M8
Ceiling mounted corner cassette
FXKQ-MA
Small concealed ceiling unit FXDQ-M9
FLOOR STANDING
CEILING SUSPENDED
WALL MOUNTED
CONCEALED CEILING
NEW ›››
1 2 3 4
Slim concealed ceiling unit Concealed ceiling unit with inverter driven fan
FXDQ-P7
FXSQ-P
Concealed ceiling unit with inverter driven fan
FXMQ-P7
Large concealed ceiling unit
FXMQ-MA3
Wall mounted unit
FXAQ-P
Ceiling suspended unit
FXHQ-MA
4-way blow ceiling suspended unit
FXUQ-MA
Floor standing unit
FXLQ-P
Concealed floor standing unit
FXNQ-P
Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m Not connectable to VRV®III-S (RXYSQ-P8V1, RXYSQ-P8Y1) Decoration panel BYCQ140CG + BRC1E51A needed
18
Capacity
CONCEALED CEILING
CEILING MOUNTED CASSETTE
Type
Model Round flow cassette autocleaning function possible
WALL MOUNTED FLOOR STANDING
CEILING SUSPENDED
NEW ›››
20
25
35
42
50
60
71
FCQ-C8
4-way blow ceiling mounted cassette
FFQ-BV
Small concealed ceiling unit
FDBQ-B
Slim concealed ceiling unit
FDXS-E/C
Concealed ceiling unit with inverter driven fan
FBQ-C
Daikin Emura
NEW ›››
Product name
Wall mounted unit
FTXG-J CTXG-J
Wall mounted unit
FTXS-J
Wall mounted unit
FTXS-G
Ceiling suspended unit
FHQ-B
Nexura floor standing unit
FVXG-K
Floor standing unit
FVXS-F
Flexi type unit
FLXS-B
The indoor units in the table above are only connectable to RXYRQ-P, RXYSQ-P8V1 and RXYSQ-P8Y1, in case of RXYRQ-P these indoor units can be combined with standard VRV® indoor units in the same system 2 Decoration panel BYCQ140CG + BRC1E51A needed 1
19
overview ventilation range Ventilation: provision of fresh air
1
Air processing: optimse the balance between indoor and outdoor fresh air temperature
Type
Product name
Components of indoor air quality
VAM-FA
1
2
Humidification: optimise the balance between indoor and outdoor humidity
2 3
Air flow rate (m3/h) 0
200
400
600
1 Ventilation
3
HEAT RECLAIM VENTILATION
VKM-G
2
1
3 Air processing
3
VKM-GM
1
2 3
OUTDOOR AIR PROCESSING UNIT 1
FXMQ-MF
VRV® AIR HANDLING APPLICATIONS 2
EKEXV-kit
1 2 3
2 3
2 Humidification
1 Ventilation 3 Air processing
3
1
1 Ventilation 3 Air processing
2
1
1 Ventilation
1 Ventilation 3 Air processing
Not connectable to VRV®III-S (RXYSQ-P8V1, RXYSQ-P8Y1) Air flow rate is a calculated indication only, based on the following values: heating capacity EKEXV-kit * 200m³/h For more information on Daikin air handling units refer to your local dealer
20
800
1,000 1,500 2,000
4,000
6,000
8,000
overview biddle air curtain range Product Name
Type BIDDLE COMFORT AIR CURTAIN (CA) FREE HANGING
CYV S/M/L/XL-DK-F
BIDDLE COMFORT AIR CURTAIN (CA) CASSETTE
CYV S/M/L/XL-DK-C
BIDDLE COMFORT AIR CURTAIN (CA) RECESSED
CYV S/M/L/XL-DK-R
Door height (m) 4
3.8m 3.5m
3.3m
Biddle comfort air curtain range
3.0m
2.8m
3
3.0m 2.5m
2.5m
2.4m
2.2m
2.2m
2
1
S
M
L
XL
S
Favourable ex: covered shopping mall or revolving door entrance
M
L
XL
M
Normal ex: little direct wind, no opposite open doors, building with ground floor only
L
XL Installation condition
Unfavourable ex: location at a corner or square, multiple floors and / or open stairwell
Overview hydrobox range Type
Product name
125
HXHD-A
HEATING ONLY HYDROBOX 1
1
Capacity
Only connectable to REYAQ-P
overview network solutions
1 2
• •
• •
•
•
+++
•
•
N/A N/A
•
Gateway for Lonworks networks Gateway for BACnet networks
21
•
•
•
•
•
•
•
•
•
8
Max. Indoors groups
• •
•
++
User friendliness
• •
+
•
•
Scheduling presets (programs)
•
ACNSS connection air conditioning network service system
•
Free cooling changeover
•
Sliding t° avoids overcooling via sensor
•
Power limit control
•
Other control functions
0° Between cooling & heating
•
Pre cooling / heating
•
Eco mode
•
Http option
•
Web acces & control
•
Ppd
•
•
Options
Visualisation
• •
BACnet 2
•
Graphical report
• •
DMS-IF 1
•
Control via GSM
•
•
Daily/monthly/yearly reports
•
•
Touch screen
Intelligent Manager
•
Password security
•
Malfunction code
•
Indication filter replacement
•
Basic monitoring functions: ON/OFF status, operation mode, set point temp.
•
Intelligent touch controller
Monitoring
Fire emergency stop control
Automatic changeover
dS-net
Weekly schedule control
Basic control functions: ON/OFF, temp. Setting, air flow settings
Control
+
4x10
+++ 2x64
128 +++ 1024
N/A 64 N/A 4x64
Powerful Selection Programmes 1. VRV ® pro, design tool Features: The VRV® Pro selection programme is a true VRV® design tool. The programme enables VRV® air conditioning systems to be engineered in a precise and economical way, taking into account the realtime thermal properties of any building. By calculating annual energy consumptions, it gives the designer the possibility to make accurate selections and get competitive quotations for each project. Moreover, it ensures optimum operating cycles and maximum energy efficiency. 1. VRV® Pro Quick: With a limited number of building properties, this mode allows to design the piping system using the available load calculation that was obtained from another party. 2. VRV® Pro Expert: To be able to make an accurate load calculation, a more extensive number of building properties is needed. After this calculation, the appropriate units are selected and a temperature simulation can be done. Next to the detailed report, there is a lot of additional, valuable information in the programme about energy consumption, related electricity expenses and behaviour of the VRV® system.
22
2. Xpress, quick quotation tool Xpress is a software tool that allows creating on the spot quotations for a Daikin VRV速 or CMS System. It provides a result in 7 steps to enable a professional budget quotation: 1. 2. 3. 4. 5. 6. 7.
Select indoor units Connect outdoor units to indoor units Automatic generation of piping diagram with joints Automatic generation of wiring diagram Select possible centralised control systems Visualise result in MS Word, MS Excel and AutoCAD Save project
The Daikin Europe Academy offers specialised training courses to teach designers how to work with VRV速 Pro. After this training, all attendees receive a renewable licence for 1 year. For more information about these trainings and to get your free copy of Xpress, please contact the local Daikin representative.
23
vrv ® outdoor systems Air cooled VRV® air conditioning was introduced to Europe by Daikin in 1987 and since then has undergone considerable development in performance, capacity, energy efficiency and environmental acceptability. Internationally regarded as one of the most
SOPHISTICATED AND VERSATILE system of its type on the market, VRV
®
has in fact, become the
benchmark for technologically advanced, high efficiency commercial and industrial air conditioning.
Available in third generation, heat recovery, heat pump, cold climate and mini versions, the VRV ® system is
EXTREMELY FLEXIBLE with an operational capacity range of 5 (14.0kW) to 54HP (170.0kW) (heat pump small footprint combination) and 8 (22.4kW) to 48HP (151.0kW) (heat recovery small footprint combination) in capacity increments of just 2HP. VRV® system versatility is also underlined by its operating temperature ranges of -5° C to 46° C in cooling (VRV®III-S) and -25° C to 15° C in heating (VRV®III-C).
Despite the remarkable energy efficiency and installation flexibility of the air cooled VRV®, there are some applications for which the water cooled version provides a more economic and sustainable solution. These apply primarily to
MULTI STOREY HIGH RISE COMPLEXES in which maximum refrigerant pipe distances can sometimes invalidate the use of an air cooled system. Further situations which are ideal for water cooled VRV® use include buildings lacking adequate roof or external space for outdoor condensing units and projects with particularly stringent noise regulations.
The water cooled VRV® is now available in 9 models between 8 and 30 HP, in heat recovery, heat pump and most recently,
GEOTHERMAL variants. The fast growing geothermal sector in fact, provides an ideal opportunity for ground source heat pumps and offers considerably future potential for its use in very low carbon installations.
24
benefits for building owners
Top quality - Only brazed connections All flange and flare connections inside the unit have been replaced by brazing connections to ensure improved refrigerant containment. Also the connection of the outdoor in the main pipe is brazed.
Flare or flange
5HP/14kW OUTDOOR UNIT
Compressor Capacity Control
The linear VRV速 system makes use of a variable Proportional Integral (PI) control system which uses refrigerant pressure sensors to give added control over inverter and ON/OFF control compressors in order to abbreviate control steps into smaller units to provide precise control in both small and larger areas. This in turn enables individual control of up to 64 indoor units of different capacity and type at a connection ratio of 50~130 % in comparison with outdoor units capacity. 5HP outdoor units use inverter control compressors only. VRV速 systems have low running costs because it permits each zone to be controlled individually. That is, only those rooms that require air conditioning will be heated or cooled, while the system can be shut down completely in rooms where no air conditioning is required.
100%
18 Steps
1 24% Small
Load
100% Compressor Capacity Control
Energy saving and indiviual zone control - Inverter technology
Large
18HP/44.5kW OUTDOOR UNIT
1 1 3 1 2 2
55 Steps
9% Small
Load
Large
Brazing
Ahead of environmental legislation RoHS Compliance Restriction of Hazardous Substances in electrical and electronic equipment (2002/95/EC). Hazardous substances include Lead (Pb), Cadmium (Cd), Hexavalent Chromium (Cr6+), Mercury (Hg), Polybrominated biphenyls (PBB), Polybrominated diphenylether (PBDE). Although RoHS regulations are only applicable to small and large household equipment, Daikin environmental policy nevertheless ensures that VRV速 will be totally in line with RoHS. 25
A long lasting investment Anti Corosion Treatment
An anti-corrosion heat exchanger cutaway view Hydrophilic film Aluminium
Special anti corrosion treatment of the heat exchanger provides 5 to 6 times greater resistance against acid rain and salt corrosion. The provision of rust proof steel sheet on the underside of the unit gives additional protection.
Corrosion-resistant Acrylic resin
Heat exchanger
Improvement in corrosion resistance Corrosion resistance rating Non-treated
Anti-corrosion treated
1 1
5 to 6 5 to 6
Salt corrosion Acid rain
VDA Wechseltest Contents of 1 cycle (7 days): ›› 24 hours salt spray test SS DIN 50021 ›› 96 hours humidity cycle test KFW DIN 50017 ›› 48 hours room temperature & room humidity testing period: 5 cycles
Degree of corrosion
Performed tests: 8 7 6 4 Bare aluminium
2 1 0 1
2
3
4
DAIKIN P.E.
5 Cycle
10 9
Kesternich test (SO2) ›› contents of 1 cycle (48 hours) according to DIN50018 (0.21) ›› testing period : 40 cycles
Degree of corrosion
8 7 6 5 4 3 2 1 0
Duty Cycling
1
2
3
Multiple outdoor units systems
The cyclical start-up sequence of multiple outdoor units systems equalized compressor duty and extends operating life.
Low installation cost - Sequential Start Up to 3 outdoor units can be connected to 1 power supply and can be turned on sequentially. This allows the number of breakers and their capacities to remain small and simplifies wiring (for models of 10HP or less). 26
4
5
6
10
20
30
40 Cycle
A solution for R-22 phase out Due to significant developments in heat pump technology, older systems of air conditioning run less efficiently than those available today. Furthermore the use of virgin R-22 is banned in Europe. To upgrade R-22 systems as cost effective as possible, Daikin replacement VRV® units can be installed using existing pipe-work.
What is R-22 and why is it phased-out in Europe? Due to ozone layer depletion, harmful ultraviolet rays reach the surface of the earth giving rise to a number of health and environmental issues. The international community therefore, signed the Montreal Protocol to phase out ozone depletion materials by 2030. The European Union however, decided to ban R-22 already in 2015. Daikin advises to replace your existing installation already today.
R-22 is a hydrochlorofluorocarbon (HCFC) which was commonly used in air conditioning systems. When R-22 is released into the air, the ultraviolet rays of the sun cause it to decompose and chlorine is released in the stratosphere. Chlorine reacts with ozone, reducing the amount of the ozone.
When will R-22 be banned in europe?
2004
2005
Ban of the sale of R-22 air conditioning equipment
2006
…
Daikin advises to replace your existing R-22 installation
2009
2010
2011
Ban on the use of virgin R-22 for service & maintenance
…
2014
2015
Ban on the use of all R-22 for service & maintenance
Only reclaimed & recycled 1 R-22 allowed
1
Recycled: re-use of R-22 following a basic cleaning process. Recycled R-22 must be re-used by the same company that carried out the recovery (can be done by installer) Reclaimed: reprocessed R-22 in order to meet the equivalent performance of virgin R-22 (by specialized company)
27
benefits for design offices and consultants A solution for every climate - Wide operation range The VRV® system can be installed practically anywhere. Advanced PI(Proportional Integral) control of the outdoor unit enables VRV® series to operate at outdoor ambients up to 43°C (VRV®III-S up to 46°C) in cooling mode and down to -20°C (VRV®III-C down to -25°C) in heating mode. With the technical cooling function the operation range in cooling of the heat recovery system is extended from -5°C to -20°C 1.
HEAT RECOVERY • HIGH COP COMBINATION • SMALL FOOTPRINT COMBINATION
HEAT PUMP OPTIMISED FOR HEATING Cooling 43°CDB
Cooling 43°CDB
50° 40° Cooling & Heating 15.5°CWB
10° 0° -10° -20°
-5°CWB
-20°CWB
-20°CWB
Heating 15.5°CWB
-5°CDB
Technical Cooling
Heating 20° 15.5°CWB
Technical Cooling
30°
1
-20°CWB
Contact your local dealer for more information and restrictions
28
Cooling 46°CDB
Heating 15.5°CWB
-5°CDB
-5°CWB
-25°CDB
VRV®III-S HEAT PUMP
Cooling 43°CDB
Heating 15.5°CWB
-20°CDB
-30°
HEAT PUMP • HIGH COP COMBINATION • WITH CONNECTION TO Stylish INDOOR UNITS • SMALL FOOTPRINT COMBINATION
-5°CDB
-20°CWB
Multiple tenants, one outdoor unit - Multi tenant function This function ensures that the entire VRV® system does not shut down when the main power supply of an indoor is switched off. This means that the indoor unit’s main fuse can be turned off when leaving a hotel room, when a part of the office building is closed, … * This option is available on the following indoor units: FXFQ-P9, FXZQ-M9, FXDQ-M9, FXDQ-PB, FXDQ-NB, FXSQ-P, FXMQ-P7, FXAQ-PV, FXLQ-P Consult the accessories table of the indoor units on necessary options.
Typical hotel application
TV
TV
TV
Power off CARD CARD
CARD
HOLDER
220 V
No structural reinforcement necessary Thanks to the vibration-free and sufficient light (max. 585kg for a 18HP unit) construction of the outdoor units, floors do not need to be reinforced, reducing the overall cost of the building.
Indoor installation The VRV®III optimised fan blade shape increases output and reduces pressure loss. Together with the high ESP setting (ESP up to 78pa), this makes the VRV® outdoor unit ideal for indoor installation and the use with ducts.
29
BENEFITS FOR installers Easy installation - Refrigerant Containment Check1 The refrigerant volume of the complete system is calculated from the following data: ›› outdoor temperature ›› reference system temperatures ›› reference pressure temperatures ›› refrigerant density ›› types and number of indoor units When activating the refrigerant containment check, the unit switches into cooling mode and duplicates certain reference conditions based on memory data. The result indicates whether or not refrigerant leakage has occurred. 1
Not available on VRV® heat pump with connection to stylish indoor units and VRV®III-S
Easy replacement - Refrigerant Recovery Function The refrigerant recovery function enables all expansion valves to be opened. In this way the refrigerant can be drained from the piping system.
Short Installation Time Thanks to small refrigerant pipes and REFNET piping options, the VRV® piping system can be installed very easily and quickly. Installation of the VRV® system can also be implemented floor by floor, so that sections of the building can be put into use very quickly, or enabling the air conditioning system to be commissioned and operated in stages, rather than on final completion of the project. 30
Automatic Charge Function Daikin’s total engineered solution ensures that, right from installation, the system has the correct refrigerant charge no matter what the original plan called for. In this way, the optimal efficiency and capacity is maintained thus delivering the correct level of heating or cooling for optimal comfort.
Conventional Way: 1. calculation of additional refrigerant charging volume 2. charging the unit with additional refrigerant 3. measuring the weight of the cylinder 4. judgment based on pressure (test operation)
VRV® With VRV® however, these 4 steps are omitted since the VRV® unit can be charged automatically with the necessary amount of refrigerant via a push button on the PCB. Automatic charging will cease once the appropriate amount of refrigerant has been transferred. If the temperature drops below 20°C* manual charging is necessary. * 10°C for heat pump for cold regions * Function not available on VRV® heat pump with connection to stylish indoor units
Automatic Test When refrigerant charging has ceased, pushing the test operation button on the PCB will initiate a check on the wiring, shut off valves, sensors and refrigerant volume. This test ceases automatically when completed.
Refrigerant Piping Front
4-way piping connection VRV® series not only offer the possibility to run piping from the front, but also from the left, right or bottom, thus providing greater freedom of layout.
Left 4-Way piping connection
Right Bottom
DAIKIN Unified REFNET piping The unified Daikin REFNET piping system is especially designed for simple installation. REFNET joint
Attached insulators for REFNET joint
REFNET header
Attached insulators for REFNET header
The use of REFNET piping in combination with electronic expansion valves, results in a dramatic reduction in imbalance in refrigerant flowing between indoor units, despite the small diameter of the piping. REFNET joints and headers (both accessories) can cut down on installation work and increase system reliability. Compared to regular T-joints, where refrigerant distribution is far from optimal, the Daikin REFNET joints have specifically been designed to optimise refrigerant flow.
REFNET joint
T-joint
Daikin Europe N.V. advises only to use Daikin REFNET piping system. 31
Modular design Modular design enables units to be joined together in rows with an outstanding degree of uniformity. The design of the outdoor units is sufficiently compact to allow them to be taken up to the top of a building in a commercial elevator, overcoming site transportation problem, particularly when outdoor units need to be installed on each floor.
Easy wiring - “Super Wiring” System
Simplified wiring A Super Wiring system is used to enable the shared use of wiring between indoor units, outdoor units and the centralised remote control. This system makes it easy for the user to retrofit the existing system with a centralised remote control, simply by connecting it to the outdoor units. Thanks to a non polarity wiring system, incorrect connections become impossible and installation time is reduced. Furthermore, outdoor units have power connection outlets on side and front, resulting in easier installation and maintenance and saving space when rows of units are connected together.
Cross wiring check The cross wiring check facility available on the VRV® is the first of its type in the industry to warn operatives of connection errors in inter unit wiring and piping. This function identifies and alerts system errors by means of on/off LEDs on the outdoor unit’s PC boards.
Auto Address Setting Function Allows wiring between indoor and outdoor units, as well as group control wiring of multiple indoor units, to be performed without the bothersome task of manually setting each address.
Easy Maintenance
Self Diagnostic Function This function operated via push button on the PCB, speeds up troubleshooting and should be used for start-up and maintenance. Disconnected thermistors, faulty solenoid valves or motor operated valves, compressor malfunctions, communication errors, etc can be diagnosed quickly. 32
BENEFITS FOR end users Smart Control Brings Comfort
Cooling
NEW ›››
Suction air temp.
An electronic expansion valve, using PID (Proportional Integral Differencial) control, continuously adjusts the refrigerant volume in respond to load variations of the indoor units. The VRV® system thus maintains comfortable room temperatures at a virtually constant level, without the temperature variations typical of conventional ON/OFF control systems.
VRV® SERIES (DAIKIN indoor unit (PID controlled)) ON/OFF controlled indoor unit (2.5HP)
Time Note: The graph shows the data, measured in a test room assuming actual heating load. The thermostat can control stable room temperature at ± 0.5°C from set point.
High sensible mode – your system optimised for the European climate The high sensible mode option on the VRV® outdoor units optimises the working of the units for the European climate. The system works with an increased sensible capacity in cooling mode resulting in improved comfort and a higher efficiency.
Higher comfort to the end user Preventing cold draughts thanks to higher discharge air temperature on the indoor unit.
16°
Two possibilities: - Standard high sensible mode: high cooling comfort with priority to capacity - Locked evaporation temperature mode: full priority to cooling comfort ›› constant and high air discharge temperature ›› easier to select air discharge grilles
Constant and high air discharge temperature
Discharge t° Locked Te mode Standard high sensible mode Standard setting
16°C 11°C 7°C Extremely high cooling load
Higher energy efficiency As no energy is wasted on unnecessary dehumidification, the system will work more efficiently in cooling mode. * Option is activated through service mode on outdoor unit. Locked Te mode is available only on RXYQ-P9 units.
Comfort guaranteed at all time Back -up Function In the event of a compressor malfunction, the remotely controlled or field set back-up function in the outdoor unit in question will allow emergency operation of another compressor, or another outdoor unit module in case of a multi system, in order to maintain 8 hour maximum interim capacity. 33
Single outdoor unit with multiple compressors
Multi outdoor unit system
Low indoor unit operation sound level ›› Daikin indoor units have very low sound operation levels, down to 25dB(A).
Silent Mode
dB(A)
Perceived loudness
Sound
0 20 40 60 80 100 120
Treshold of hearing Extremely soft Very soft Moderately loud Very loud Extremely loud Threshold of feeling
Rustling leaves Quiet room Normal conversation City traffic noise Symphonic orchestra Jet taking off
Daikin indoor units
Outdoor Units Quietness is another important feature. To reduce noise and ensure comfortable operation, the latest technologies and features have been applied to the outdoor units.
VRV® air cooled units
VRV®III-S air cooled units
Night quiet function (max. -13dBA)
Night quiet function (max. -8dBA)
Peak in the outdoor temperature
%
8 hrs
Peak in the outdoor temperature
%
8 hrs
10 hrs
10 hrs
%
%
Night Mode dBA
dBA
Night Mode
dBA dBA
Step 1: max. - 8dB (10HP)
Step 1: 50dB
Step 2: max. - 13dB (10HP)
Step 2: 45dB
dBA dBA
Step 1 max. - 3dB (4HP/11.2Kw)
Step 1: 47dB
Step 2 max. - 6dB (4HP/11.2Kw)
Step 2: 44dB
Step 3 max. - 9dB (4HP/11.2Kw)
Step 3: 41dB
time of day
time of day Night mode starts
Night mode starts
Night mode ends
— Capacity* %
Notes:
— Load %
This function is available for on site setting.
Night mode ends
The relationship between outdoor temperature (load) and time shown in
— Operation Sound dBA
the graph is merely an example.
During the night the sound level of the outdoor unit can be reduced for a certain period: starting time and ending time can be put in 2 modes1 with low sound level at night: ›› Mode 1 Automatic mode Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours2 after the peak temperature in the daytime and operation will return to normal after 10 hours3. ›› Mode 2 Customized mode Starting and ending times can be put in. (External control adapter for outdoor unit, DTA104A61 or DTA104A62 and a separately ordered timer are necessary.) Notes:
1
2
3
Determine which mode to select depending on the climatic characteristics of each country. Initial setting. Can be selected from 6, 8 and 10 hours. Initial setting. Can be selected from 8, 9 and 10 hours.
Effect on capacity (cooling) when using silent mode Soundlevel Step 1
50dB
Step 2
45dB
Capacity (kW) Capacity (kW)
5HP 14.7 100% 11.9 93%
8HP 19.9 98% 15.1 74%
10HP 19.9 78% 15.1 59%
* Data appicable for standard air cooled units
34
12HP 20.9 69% 15.6 51%
14HP 19.9 55% 15.5 43%
16HP 20.1 49% 15.6 38%
18HP 20.2 44% 15.6 34%
advanced VRV ® technologies:
3 4 2
2
1
1
Iron
1 Reluctance Brushless DC Compressor ››
››
››
The reluctance brushless DC motor provides significant increases in efficiency compared to conventional AC inverter motors, simultaneously using 2 different forms of torque (normal and reluctance torque) to produce extra power from small electric currents. The motor comprises powerful neodymium magnets, that efficiently generate high torque. These magnets make a major contribution to the energy saving characteristics of the motor. High thrust mechanism (VRV® heat pump) By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound level.
35
Rotating Stator Field
Neodymium Magnet
“Normal” torque Reluctance torque
Suction Low pressure side
Scroll Discharge
High pressure side
Reluctance DC Motor
Sine Wave DC Inverter 2 Optimizing the sine wave curve, results in smoother motor rotation and improved motor efficiency.
3 DC Fan Motor
DC motor efficiency 100
The use of a DC fan motor offers substantial improvements in operating efficiency compared to conventional AC motors, especially during low speed rotation.
(comparison with a conventional AC motor)
Efficiency (%)
80
DC fan motor structure
60 40 AC motor
20 0
200 300 400 500 600 700 800 900 1000 Motor speed (rpm)
Standard heat exchanger
4 e-Pass Heat Exchanger Optimization of the path layout of the heat exchanger prevents heat transferring from the overheated gas section towards the sub cooled liquid section - a more efficient use of the heat exchanger.
OUT 45°C
IN 85°C
e-pass heat exchanger
OUT 45°C
IN 85°C
55°C
27°C
27°C
55°C
27°C
60°C
27°C
50°C
27°C
55°C
27°C
55°C
37°C
OUT 45°C
43°C
OUT 45°C
Power
5 i-Demand Function The newly introduced current sensor minimizes the difference between the actual power consumption and the predefined power consumption.
consumption (KVV)
In cooling mode, the heat exchanger of the condensor is improved. This means an improvement of COP by 3%.
8:00
12:00
16:00 Time
36
20:00
REYAQ-P
VRVIII heat recovery, with connection to heating only hydrobox
›› The total solution VRV –– Cooling, heating, ventilation and hot water from a single system –– Virtually free hot water production from recovered heat in cooling operation –– Total Coefficient of Performance (COP) approaching 9 in simultaneous cooling & heating operation
High ESP Fans SHR =1
High sensible mode
›› … and other benefits of Daikin VRV® III Heat Recovery technology
Cooling 22
Extracted heat 22
Heating
Hot Water
VRV® heat recovery system
Ventilation
Air Curtain
Daikin has been the market leader in variable refrigerant flow systems for the last twenty-five years and benefits from a large experience in energy efficient hot water systems based on heat pump technology. The Daikin VRV® total solution provides a single point of contact for the design and maintenance of your integrated climate control system. Our heat recovery approach is a year-round solution: even when the outside temperature is 0ºC or below, our total solution will still be cooling interior spaces in which people or equipment are generating heat. This heat will be recovered to produce hot water or to heat spaces that are below optimal temperature. Our wide product portfolio enables you to select the right mix of equipment and technology to ensure that you achieve the optimal balance of temperature, humidity and air freshness for the perfect comfort zone with maximum energy efficiency and cost effectiveness. 38
REYAQ-P
VRVIII heat recovery, with connection to heating only hydrobox
A highly efficient and flexible solution
All components integrated
45°C - 75°C
OR EKHWP 45°C - 75°C
EKHTS
25°C - 45°C
25°C - 75°C
REYAQ-P
HXHD125A
100% thermo dynamic energy High performance in 3 steps: Outdoor
1. The outdoor unit extracts heat from the ambient outdoor air.
This heat is transferred to the hydrobox via R-410A refrigerant. 2. The indoor unit receives the heat and further increases the temperature with R-134a refrigerant. 3. The heat is transferred from the R-134a refrigerant circuit to the water circuit. Thanks to the unique cascade compressor approach, water temperatures of 80° C can be reached without using an additional back-up heater.
39
Step
1
Indoor Step
expansion valve
2
Step
3
heat exchanger valve
compressor
REYAQ-P
The height difference between the outdoor unit’s and indoor units’ installation can be up to 40 m. The maximum distance from the first branch to an indoor unit is 40 m. Branch selectors (BS units) are not taken into account, as their installation does not influence the piping design.
1
40m maximum
100m Actual piping length
VRV® offers an extended piping length of 100 m (120 m equivalent piping length) with a total system piping length of 300 m.
40m Level difference between indoor and outdoor units
flexible Piping design
15m Level difference between indoor units
VRVIII heat recovery, with connection to heating only hydrobox
Heat recovery Outdoor unit Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Indoor index Min. connection Nom. Max. HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Hot water Min.~Max. production Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Discharge gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
HP kW kW kW kW
mm kg dBA dBA °CDB °CWB °CDB °CDB mm mm mm m m m Hz/V A
REYAQ10P 10 28 31.5 7.09 7.38 3.95 4.27 21 125 250 325
REYAQ12P 12 33.5 37.5 8.72 8.84 3.84 4.24 26 150 300 390
REYAQ14P 14 40 45 11.4 11.0 3.51 4.09 30 175 350 455 1,680x1,300x765
331 78 58
339 80 60
83 62
Nom. Colour Material HeightxWidthxDepth Dimensions Unit Weight Unit Sound pressure Nom. level Night quiet mode Level 1 Operation range Heating Ambient Min.~Max. Water side Min.~Max. Domestic hot Ambient Min.~Max. water Water side Min.~Max. Refrigerant Type Refrigerant circuit Gas side diameter Liquid side diameter Water circuit Piping connections diameter Heating water system Water volume Min.~Max. Power supply Phase/Frequency/Voltage Current Recommended fuses
84 63
-5~43 -20~15.5 -20~20 / 24 (1) (Space heating) -20~43 (Domestic hot water) R-410A 9.52 22.2
12.7 28.6 19.1
22.2 100 300 40 (Outdoor unit in highest position)/ 40 (Indoor unit in highest position) 3~/50/380-415
25
40
(1) Field setting
Indoor unit Heating capacity Casing
REYAQ16P 16 45 50 14.1 12.8 3.19 3.91 34 200 400 520
HXHD125A 14.0 Metallic grey Precoated sheet metal 705x600x695 92 42 (1) / 43 (2) 38 (5) -20~20 / 24 (3) 25~80 -20~43 45~75 R-134a 12.7 9.52 G 1” (female) 20~200 1~/50/220-240 20
kW
mm kg dBA dBA °C °C °CDB °C mm mm inch l Hz/V A
(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting
40
REYQ-P8/P9 REYHQ-P9
VRV® III heat recovery Small footprint & high COP combinations
›› Functionality unique in the market –– Continuous heating even during defrost –– Continuous operation during cool-heat switch –– Cooling & Heat Recovery operation range down to -20°C in technical cooling mode
Automatic refrigerant charging Refrigerant leak check
›› Highest efficiency on the market –– Total COP over 9 in simultaneous cooling-heating operation
High ESP Fans SHR =1
›› Unprecedented installation flexibility –– Longest piping lengths in the market –– Up to 64 indoor units –– Up to 200% connection ratio –– Up to 78 Pa ESP on outdoor fan
High sensible mode
Continuous heating during defrost
Individual comfort thanks to VRV®III BS box
››
Individual change over from cooling to heating or vice versa of the indoor units is possible. This means that all indoor units who do not change over continue to provide optimum comfort for the users during this process.
High comfort -- No cold draft during defrost & oil return -- No big temperature fluctuations in the room ›› Higher integrated heating capacity (indoor units continue to deliver heating) -- Continuous heating during defrost results in a higher integrated heating capacity and much higher comfort levels for the users.
VRV®III With the VRV®III BS box, the other indoor units can keep heating while the target indoor units are switched from cooling to heating.
* O nly available for multi combination heat recovery systems (REYQ18-48P8/9, REYHQ16-24P) VRV®III Heat recovery
2 3
1
only 1 outdoor coil at a time performs defrost operation
fan off continuous heating (reduced capacity)
hot start
full heating capacity
42
REYQ-P8/P9 REYHQ-P9 + 11%
VRV® III heat recovery Small footprint & high COP combinations
4.30
COP
4.20
Did you know that…
+ 11%
4.40
4.10 3.90 3.80 High COP range
3.70 3.60
Small footprint range
16
20
22
24
… the Daikin VRV® system regularly delivers a Coefficient of Performance (COP) of 4 or more, meaning that it produces four units of heat energy for every one unit of electrical energy used. However, when operating in heat recovery mode, the COP can be has high as 10, making the Daikin VRV® system the most advanced of its kind.
Top energy efficiency in Daikin heat recovery range, thanks to the redesigned 8HP modular unit and newly developed 12HP high COP modular unit Ideal situation when heating and cooling
10 8 7
COP
6
HEAT RECOVERY • HIGH COP COMBINATION • SMALL FOOTPRINT COMBINATION
5
4
3 2
50°
1 0
Cooling 43°CDB
40°
20
40
Only cooling
30°
0° -10° -20° -30°
-5°CWB
-20°CWB
80
-5°CDB
-20°CWB
-20°CDB
After the first branch, the difference between the longest piping length and the shortest piping length can be maximum 40m, provided that the longest piping length amounts to maximum 90m. For more information, please contact your local Daikin dealer. Branch selectors (BS units) are not taken into account, as their installation does not influence the piping design.
1 1
43
90m maximum
In case the outdoor unit is located above the indoor unit the height difference is 50m standard. It can be extended to 90m1. In case the outdoor unit is located below the indoor unit, the height difference is 40m standard. Height differences up to maximum 90m are possible1.
15m Level difference between indoor units
VRV® offers an extended piping length of 165m (190m equivalent piping length) with a total system piping length of 1,000m.
165m Actual piping length
flexible Piping design
40m (90m1) Level difference between indoor and outdoor units
Note: Heating operation range is defined in Wet Bulb temperature. 15.5°CWB translates to approximately 21~25°C Dry Bulb temperature under usual climate conditions.
100
Only heating
Coefficient of performance of a Daikin VRV® heat recovery system
Cooling & Heating 15.5°CWB Technical Cooling
Heating 10° 15.5°CWB
Technical Cooling
20°
60
50% heating 50% cooling
REYQ-P8/P9 REYHQ-P9
VRV® III heat recovery Small footprint & high COP combinations
Heat recovery - small footprint combinations Outdoor system Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Discharge gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor system System
Outdoor unit module HeightxWidthxDepth Dimensions Unit Weight Unit Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
REYQ10P8 10 28.0 31.5 7.09 7.38 3.95 4.27 21
78
331 78
HP kW kW kW kW
dBA mm mm mm mm m m m Hz/V A
HP kW kW kW kW
REYQ12P9 12 33.5 37.5 8.72 8.84 3.84 4.24 26 1,680x1,300x765
REYQ14P8 14 40.0 45.0 11.4 11.0 3.51 4.09 30
80 60 -20 (1) / -5~43 -20~15.5 R-410A
83 62
9.52 19.1 15.9
84 63
12.7 28.6
22.2 19.10
22.2
165 1,000 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 3~/50/380-415 25
20 REYQ18P9 REYQ20P9 REMQ8P9 REMQ10P8 18 20 50.4 55.9 56.5 62.5 12.7 14.9 13.4 15.2 3.97 3.75 4.22 4.11 39 43 81
REYQ22P8 REMQ10P8 REMQ12P8 22 61.5 69.0 17.0 17.1 3.62 4.04 47
REYQ16P8 16 45.0 50.0 14.1 12.8 3.19 3.91 34 339
58
mm mm mm m m m Hz/V A
Outdoor unit module 1 Outdoor unit module 2
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound power level Cooling Nom Piping Liquid OD connections Gas OD Discharge gas OD Oil equalizing OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
REYQ8P9 8 22.4 25.0 5.20 5.71 4.31 4.38 17
mm kg dBA dBA °CDB °CWB
Outdoor unit module 1 Outdoor unit module 2
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound power level Cooling Nom Piping Liquid OD connections Gas OD Discharge gas OD Oil equalizing OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor system System
HP kW kW kW kW
REYQ24P8 REMQ12P8
REYQ26P8 REMQ10P8
24 67.0 75.0 19.2 18.9 3.49 3.97 52
26 73.0 81.5 21.8 20.6 3.35 3.96 56 83
40
REYQ28P8 REYQ30P8 REYQ32P8 REMQ12P8 REMQ14P8 REMQ16P8 REMQ16P8 28 30 32 78.5 85.0 90.0 87.5 95.0 100 23.8 26.6 28.4 22.3 24.2 25.8 3.29 3.19 3.16 3.92 3.87 60 64
15.9
19.1
28.6
34.9
22.2
28.6 19.1 165 1,000 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 3~/50/380-415 50 60
45 REYQ34P9 REYQ36P9 REMQ8P9 REMQ10P8 34 36 95.4 101 107 113 26.9 29.1 26.3 28.1 3.55 3.47 4.07 4.02
REYQ38P8 REMQ10P8 REMQ12P8 38 107 119 31.2 30.0 3.43 3.96
REYQ40P8 REMQ12P8
REYQ42P8 REMQ10P8
40 112 125 33.4 31.8 3.35 3.93
42 118 132 35.8 33.5 3.29 3.94
70
REYQ44P8 REYQ46P8 REMQ12P8 REMQ14P8 REMQ16P8 44 46 124 130 138 145 38.0 40.8 35.2 37.1 3.26 3.18 3.92 3.90
REYQ48P8 REMQ16P8 48 135 150 42.6 38.7 3.16 3.87
64 dBA mm mm mm mm m m m Hz/V A
84
85 19.1
34.9
41.3 28.6
80 REMQ8P9
mm kg °CDB °CWB
34.9 19.1 165 1,000 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 3~/50/380-415 90 100 REMQ10P8 1,680x930x675
204
REMQ12P8 254 -20 (1) / -5~43 -20 ~ 15.5 R-410A 3~/50/380-415
Hz/V A
(1) Field setting
44
110
REMQ14P8 REMQ16P8 1,680x1,240x765 334
REYQ-P8/P9 REYHQ-P9
VRV® III heat recovery Small footprint & high COP combinations
Heat recovery - high COP combinations Outdoor system System
REYHQ16P Outdoor unit module 1 Outdoor unit module 2
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit module HeightxWidthxDepth Dimensions Unit Weight Unit Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
REYHQ20P
REYHQ22P REMQ10P8 REMHQ12P8 22 61.5 69.0 16.0 16.3 3.84 4.24 47
REMQ8P9 HP kW kW kW kW
REMQ8P9 16 45.0 50.0 10.5 11.5 4.29
20 56.0 62.5 13.9 14.3 4.04 4.36
dBA dBA mm mm m m Hz/V A
34 82 62 12.7
43 85 64
24 67.0 75.0 17.2 17.2 3.89 4.37 52 87 66
15.9 28.6
34.9
1,000 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 3N~/50/380-415 63
50 REMQ8P9
mm kg °CDB °CWB
REYHQ24P REMHQ12P8
REMQ10P8 1,680x930x765
204
254 -5~43 -20~15 R-410A 3~/50/380-415 -
Hz/V A
45
80 REMHQ12P8 1,680x1,300x765 331
3N~/50/380-415 40
RXYQ-P9 RXYHQ-P9
Automatic refrigerant charging Refrigerant leak check High ESP Fans SHR =1
High sensible mode
VRV®III heat pump, small footprint & high COP combinations
›› Unprecedented installation flexibility –– Up to 1000 m of total piping –– Up to 90 m elevation difference between indoor and outdoor units –– Up to 165 m between indoor and outdoor units –– Up to 64 indoor units –– Up to 200% connection ratio –– Up to 78 Pa ESP on outdoor fan & indoor installation ready ›› Installation & legislation friendly –– Automatic refrigerant charging –– Refrigerant leak check
After the first branch, the difference between the longest piping length and the shortest piping length can be maximum 40m, provided that the longest piping length amounts to maximum 90m. * For more information, please contact your local Daikin dealer.
46
90m maximum
15m Level difference between indoor units
In case the outdoor unit is located above the indoor unit the height difference is 50m standard. It can be extended to 90m*. In case the outdoor unit is located below the indoor unit, the height difference is 40m standard. Height differences up to maximum 90m are possible*.
165m Actual piping length
VRV® offers an extended piping length of 165m (190m equivalent piping length) with a total system piping length of 1,000m.
40m (90m*) Level difference between indoor and outdoor units
flexible Piping design
RXYQ-P9 RXYHQ-P9
VRV®III heat pump, small footprint & high COP combinations
top energy efficiency
The high COP combination has a top energy efficiency within the Daikin heat pump range. It is up to 16% more efficient. compared to the small footprint combination. +16% HP combination COP EER combination COP EER
High COP combination Small footprint combination
12
16
18
20
22
12 4.37 3.89 12 3.97 3.48
8+8 4.50 4.29 16 3.88 3.17
8 + 10 4.27 4.00 18 3.69 3.02
8 + 12 4.42 4.05 8 + 12 4.18 3.80
10 + 12 4.24 3.84 10 + 12 4.04 3.62
24
26
28
30
32
34
36
8 + 8 + 8 8 + 8 + 10 8+10+10 8+10+12 8+12+12 10+12+12 12+12+12 4.50 4.34 4.44 4.31 4.40 4.29 4.37 4.29 4.09 4.12 3.96 3.99 3.85 3.89 12 + 12 8 + 18 10 + 18 12 + 18 14 + 18 16 + 18 18 + 18 3.97 3.94 3.83 3.81 3.83 3.79 3.69 3.49 3.41 3.26 3.20 3.11 3.09 3.02
Seasonal Performance The European 20/20/20 targets press energy users to drastically cut energy consumption and improve energy efficiency of buildings. In order to have a good view on the yearly running costs & CO2 emissions of your air conditioning system, a seasonal performance indication is required. The current standards do not provide real guidance on the yearly performance of a VRV® system, as only one nominal point in cooling and one nominal point in heating is published. To correct this, a more accurate calculation method – the Seasonal Efficiency Ratio/Seasonal coefficient of performance - or SEER/SCOP – is being developed by the EU, in view of the upcoming Eco Design Directive for air conditioners > 12 kW. This will require AC manufacturers to provide yearly performance data (SEER/SCOP).
Daikin leads the market by publishing seasonal performance data Until the new calculation method is known, Daikin already publishes ESEER and APF values today. ESEER The ESEER values provide a clear view on the part-load cooling performance of VRV® III. Thus enabling estimation of the annual power consumption in cooling mode. The ESEER values published for air-cooled VRV® systems allow a comparison with other air-cooled systems only; when comparing with air-cooled chillers, auxiliary power consumption of circulation pumps still needs to be added to the chiller performance. 1 ESEER: formula: ESEER= 0,03* EERA + 0,33* EERB + 0,41* EERC + 0,23* EERD
condition
load
A B C D
100% 75% 50% 25%
indoor temperature conditions: 19°CWB/27°CDB
ambient temperature 35°CDB 30°CDB 25°CDB 20°CDB
For chillers the outdoor power input is taken into account (excluding pumps and indoor units), for VRV® the outdoor power input is taken into account (excluding indoor units).
APF The Annual Performance Factor or APF is the Japanese seasonal performance benchmark for VRF systems, which allows users to gauge the true seasonal performance of a VRF system in both heating and cooling. 2 APF: Formula: Accumulated heating & cooling loads (kWh) (1*2) / accumulated power input in heating and cooling (kWh) (2*3) RXYQ-P9 EER ESEER APF
5 3.98 6.13 5.0
8 4.29 6.61 5.4
10 3.77 5.83 5
12 3.48 5.37 4.6
14 3.23 4.96 4.6
1 Load depending on outdoor
5
10
200
Below 17°C no cooling required
15
20
25
Ambient temperatures (°C)
Occurence (h)
Load (kW) 0
18 3.02 4.67 4.2
20 3.80 5.89 4.9
22 3.62 5.59 4.8
24 3.49 5.38 4.6
26 3.41 5.28 4.6
28 3.26 5.09 4.5
30 3.20 4.95 4.4
32 3.11 4.81 4.4
34 3.09 4.78 4.3
36 3.02 4.67 4.2
38 3.43 5.31 4.6
30
35
Heating period
40 3.34 5.18 4.5
42 3.28 5.07 4.4
44 3.25 5.03 4.4
46 3.17 4.93 4.4
48 3.14 4.84 4.3
50 3.08 4.76 4.3
52 3.07 4.74 4.3
54 3.02 4.67 4.2
3 Power input curves
2 Temperature occurence (Tokyo)
temperature (office) Above 11°C no heating required
16 3.17 4.89 4.4
Based on: - Tokyo climate - 6 days/week - From 8 AM to 8 PM
Cooling period
100
0
5
10
15
20
25
Ambient temperatures (°C)
30
35
kW
-5 0
5
10
15
20
25
30
35
40
Ambient temperatures (°C)
1 ESEER: Conditions: indoor temp. 27°C DB/19°C WB; outdoor temp. 35°C; 30°C; 25°C; 20°C. Formula: EER at 35°C * 0.03 + EER at 30°C * 0.33 + EER at 25°C * 0.41 + EER at 20°C * 0.23. For chillers the outdoor power input is taken into account (excluding pumps, cooling towers, indoor units, …), for VRV® the outdoor power input is taken into account (excluding indoor units). 2 APF: Formula: Accumulated heating & cooling loads (kWh) (1*2) / accumulated power input in heating and cooling (kWh) (2*3)
47
RXYQ-P9 RXYHQ-P9
VRV®III heat pump, small footprint & high COP combinations
Heat pump - small footprint combinations Outdoor unit System Capacity range Cooling capacity Heating capacity Power input - 50Hz
Outdoor unit module 1 Nom. Nom. Cooling Heating
Nom. Nom.
EER COP APF Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit System
mm kg dBA dBA °CDB °CWB mm mm m m m Hz/V A
HP kW kW kW kW
dBA dBA mm mm m m m Hz/V A
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP APF Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
HP kW kW kW kW
RXYQ10P9 RXYQ12P9 RXYQ10P9 RXYQ12P9 10 12 28.0 33.5 31.5 37.5 7.42 9.62 7.70 9.44 3.77 3.48 4.09 3.97 5 21 26 1,680x930x765 240
187
RXYQ14P9 RXYQ14P9 14 40.0 45.0 12.4 11.30 3.23 3.98 4.6 30
78 57
RXYQ16P9 RXYQ16P9 16 45.0 50.0 14.2 12.90 3.17 3.88 4.4 34 1,680x1,240x765 316
80 60
58
9.52 19.1
15.9
12.7 22.2
RXYQ18P9 RXYQ18P9 18 49.0 56.5 16.2 15.30 3.02 3.69 4.2 39 324 83 63
20 55.90 62.50 14.71 14.95 3.80 4.18 4.9 43
RXYQ22P9 RXYQ10P9 RXYQ12P9 22 61.50 69.00 16.99 17.08 3.62 4.04 4.8 47 83
62
RXYQ24P9 RXYQ12P9
RXYQ26P9 RXYQ8P9
RXYQ28P9 RXYQ10P9
24 67.00 75.00 19.20 18.89 3.49 3.97
26 71.40 81.50 20.94 20.69 3.41 3.94
28 77.00 88.00 23.62 22.98 3.26 3.83 4.5 60
4.6 52
56
63
RXYQ30P9 RXYQ32P9 RXYQ12P9 RXYQ14P9 RXYQ18P9 30 32 82.50 89.00 94.00 102.00 25.78 28.62 24.67 26.63 3.20 3.11 3.81 3.83 4.4
RXYQ34P9 RXYQ16P9
RXYQ36P9 RXYQ18P9
34 94.00 107.00 30.42 28.23 3.09 3.79 4.3
36 98.00 113.00 32.45 30.62 3.02 3.69 4.2
64
64
34.9 165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 63
50
86 66
65 19.1
15.9
RXYQ40P9 RXYQ10P9 RXYQ12P9 40 111.00 126.00 33.23 32.39 3.34 3.89 4.5
40
85
28.6
38 105.00 119.00 30.61 30.13 3.43 3.95 4.6
15.9 28.6
165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 25
16
RXYQ38P9 RXYQ8P9
Outdoor unit module 1 Outdoor unit module 2
RXYQ8P9 RXYQ8P9 8 22.4 25.0 5.22 5.56 4.29 4.50 5.4 17
-5.0~43.0 -20~15 R-410A
RXYQ20P9 RXYQ8P9
Outdoor unit module 1 Outdoor unit module 2
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP APF Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit System
HP kW kW kW kW
RXYQ5P9 RXYQ5P9 5 14.0 16.0 3.52 4.00 3.98 4.00 5.0 10 1,680x635x765 159 72 54
RXYQ42P9 RXYQ12P9
RXYQ44P9 RXYQ8P9
RXYQ46P9 RXYQ10P9
42 116.00 132.00 35.37 34.20 3.28 3.86
44 120.00 138.00 36.92 35.94 3.25 3.84 4.4
46 126.00 145.00 39.75 38.26 3.17 3.79
RXYQ48P9 RXYQ50P9 RXYQ12P9 RXYQ14P9 RXYQ18P9 48 50 132.00 138.00 151.00 158.00 42.04 44.81 39.95 41.91 3.14 3.08 3.78 3.77 4.3
41.3
80 RXYQ52P9 RXYQ16P9
RXYQ54P9 RXYQ18P9
52 143.00 163.00 46.58 43.47 3.07 3.75
54 147.00 170.00 48.68 45.95 3.02 3.70 4.2
64 dBA dBA mm mm m m m Hz/V A
86 66
87 67 19.1 41.3 165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 100
48
88 68
125
RXYQ-P9 RXYHQ-P9
VRV®III heat pump, small footprint & high COP combinations
Heat pump - high COP combinations Outdoor system System Capacity range Cooling capacity Heating capacity Power input - 50Hz
Nom. Nom. Cooling Heating
Nom. Nom.
EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor system System
RXYHQ12P9 RXYHQ12P9 12 33.5 37.5 8.61 8.58 3.89 4.37 26 1,680x1,240x765 281 80 60 -5.0~43.0 -20.0~15.0 R-410A 12.7 28.6 165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 25
Outdoor unit module 1 HP kW kW kW kW
mm kg dBA dBA °CDB °CWB mm mm m m m Hz/V A
Outdoor unit module 1 Outdoor unit module 2 Outdoor unit module 3
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit module HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
HP kW kW kW kW
dBA dBA mm mm m m m Hz/V A
RXYHQ16P9 RXYHQ18P9 RXYHQ20P9 RXYHQ22P9 RXYHQ24P9 RXYHQ26P9 RXYHQ28P9 RXYHQ30P9 RXYHQ32P9 RXYHQ34P9 RXYHQ36P9 RXYQ8P9 RXYQ10P9 RXYQ8P9 RXYQ10P9 RXYHQ12P9 RXYQ8P9 RXYQ10P9 RXYHQ12P9 RXYQ8P9 RXYQ10P9 RXYHQ12P9 RXYQ8P9 RXYQ10P9 RXYHQ12P9 16 18 20 22 24 26 28 30 32 34 36 45.00 49.00 55.90 61.50 67.00 71.40 77.00 82.50 89.00 94.00 98.00 50.00 56.50 62.50 69.00 75.00 81.50 88.00 94.00 102.00 107.00 113.00 10.49 12.25 13.80 16.02 15.62 17.46 18.69 20.83 22.31 24.42 25.19 11.11 13.23 14.14 16.27 16.67 18.78 19.82 21.81 23.18 24.94 25.86 4.29 4.00 4.05 3.84 4.29 4.09 4.12 3.96 3.99 3.85 3.89 4.50 4.27 4.42 4.24 4.50 4.34 4.44 4.31 4.40 4.29 4.37 34 39 43 47 52 56 60 64 82 83 85 60 61 62 63 64 65 12.7 15.9 19.1 28.6 34.9 41.3 165 1,000 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 50 63 80 RXYQ8P9
mm kg dBA dBA °CDB °CWB
RXYQ10P9 1,680x930x765
187
240 78
57
58 -5.0~43.0 -20~15 R-410A 3N~/50/400 25
Hz/V A
49
RTSYQ-P
Automatic refrigerant charging Refrigerant leak check High ESP Fans SHR =1
VRV®III heat pump, optimised for heating
›› Unprecedented functionality and performance –– Genuine two-stage compression –– Heating operation guaranteed down to -25°C –– Constant capacity down to -5°C –– COP > 3 down to -15°C –– 80% of capacity available down to -20°C –– 50% shorter start-up and defrost times
High sensible mode
COP for a 10HP unit
High COP at low ambients
4.00
The use of two stage compression technology results in improved energy saving performance at low ambients, with a COP of more than 3.0 at -10°C outdoor ambient for the entire range (up to 3.8 for a 10HP unit). Annual power costs are therefore, considerably lower than those of the standard heat pump.
3.00 COP
mp
®
VRV dard
2.00
t pu hea
Stan
1.00 0.00 -25
-20
-15
-10
-5
0
5
10
Outdoor temp. (WB°)
WIDE HEATING OPERATION RANGE
HEATING
COOLING
50
VRV III-C +43 °CDB ®
40 outdoor temperature
VRV®III-C is the first system on the market with a standard operation range down to -25 °CWB outdoor ambient in heating and can also provide cooling down to - 5 °CDB outdoor ambient.
30 20
VRV® III-C +15.5 °CWB
VRV® +43 °CDB
VRV® +15.5 °CWB
10 -5
-5 °CDB
-5 °CDB
-10 -15 -20 °CWB
-20 -25 °CWB
-25
Heating capacity 10HP outdoor unit
STABLE heating capacity
(kW) heating capacity
35
VRV®III-C has a stable heating capacity, even in low ambients, making it suitable for single source heating. The heating capacity is 130% in comparison with the standard VRV® heating capacity under similar conditions
30 25
standard heat pump
20 15 10 5 0
50
-25
-20
-15 -10 -5 Outdoor temp. (°CWB)
0
5
10
RTSYQ-P
VRV®III heat pump, optimised for heating
High heat up speed Heat up time is dramatically reduced, particularly under low ambient conditions. The required time for the indoor unit heat exchanger discharge temperature to reach 40°C has been reduced by 50%. °C
Start heating operation
60 35 50
30
30 20
25
10 Standard heat pump
0
20
-5
0
5 6 10 Elapsed time (min.)
Indoor heat exchanger temperature standard heat pump X +10
15 -20
Indoor heat exchanger temperature VRV®III-C
Indoorpositie temperatureblauwe VRV®III-C lijnen:
50% reduction
-10
Indoor temperature °C
Discharge temperature (°C)
40
14 15
20
Indoor temperature standard heat pump * Field test data in Japan with 14 HP unit (Akita City Jan 2006)
Short defrost time The time required for defrost is reduced to 4 minutes – less than half that of the standard VRV®III system (10 minutes), leading to a more stable interior indoor temperature and considerably improved comfort levels. * Field test data in Japan with 10 HP unit (Akita City Jan 2006)
Heating capacity
TWO STAGE COMPRESSION High
Liquid injection
Pressure
Gas-liquid separator Middle
Gas injection
Low
Evaporator capacity
Input power
Enthalpy
51
Two stage compression technology enables the system to create higher pressures resulting in a higher heating capacity under low ambient conditions. The second inverter compressor (located in the function unit) is specially designed to provide higher pressures. After heat is exchanged in the indoor unit, gas and liquid are separated at the gas-liquid separator. This enables the refrigerant in gas condition to be recovered and transmitted direct to the high pressure compressor.
RTSYQ-P
VRV®III heat pump, optimised for heating
90m maximum
165m Actual piping length
VRV®III-C offers an extended piping length of 165m (190m equivalent piping length) with a total system piping length of 500m. If the outdoor unit is located above the indoor unit, the height difference is 50m. If the outdoor unit is located below the indoor unit, the height difference is 40m. The distance between the outdoor unit and the function unit should be a maximum of 10m (13m equivalent piping length). After the first branch, the difference between the longest piping length and the shortest piping length can be a maximum 40m, provided that the longest piping length amounts to a maximum of 90m.
50m Level difference between indoor and outdoor units 15m Level difference between indoor units
Flexible piping design
Heat pump Outdoor system System
Outdoor unit module 1 Outdoor unit module 2 Function unit
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound pressure level Cooling Max./Nom. Piping Liquid OD connections Gas OD Oil equalizing OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
RTSYQ10P RTSQ10P
RTSYQ14P RTSQ14P -
10 28.0 (1) 31.50 (2) / 28.0 (3) 7.90 7.70 3.54 4.09 21 62/60 9.52 22.2
14 40.0 (1) 45.0 (2) / 40.0 (3) 12.6 11.3 3.17 3.98 30 63/61
RTSYQ16P RTSQ16P
RTSYQ20P RTSQ8P RTSQ12P
16 45.0 (1) 50.0 (2) / 45.0 (3) 14.9 12.9 3.02 3.88 34
20 55.9 (1) 62.5 (2) / 56.0 (3) 15.4 15.3 3.63 4.01 43
BTSQ20P HP kW kW kW kW
dBA mm mm mm m m m Hz/V A
65/63 12.7
15.9 28.6
-
19.1
165 500 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3~/50/380-415 35 40
25
50
(1) Cooling: Indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m; level difference: 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (2) Heating: Indoor temp. 20°CDB; outdoor temp. 7°CDB,6°CWB; equivalent piping length: 7.5m; level difference: 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (3) Heating: Indoor temp. 20°CDB; outdoor temp. -10°CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units
Outdoor unit module HeightxWidthxDepth Dimensions Unit Weight Unit Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
RTSQ8P mm kg °CDB °CWB Hz/V A
RTSQ10P 1,680x930x765
205
RTSQ12P 257
RTSQ14P RTSQ16P 1,680x1,240x765 338 344
BTSQ20P 1,570x460x765 110
-5 ~ 46 -25 ~ 15.5 R-410A 3~/50/380-415 25
52
35
40
20
RXYRQ-P
VRV®III heat pump, with connection to stylish indoor units
›› Widest portfolio of connectable indoor units on the market: 25 types of indoor units to choose from ›› Have in one system: –– Quietest indoor units on the market – down to 19 dB(A) –– Units with award-winning design – the Daikin Emura –– Units with unique functionality – radiation function of the Nexura –– Units with unique power – VRV concealed ceiling units with up to 270 Pa of ESP and 28 kW of nominal cooling capacity
NEW
High ESP Fans
Including connection to
n to nectio n o c g cludin ura
Nexura
In
More info
rmation in
the Resid
n Em
Daiki
in ation
inform More
ential Cata
logue
FXSQ-P VRV® indoor unit FTXG-J
FVXS-F
BPMKS967B3
FTXS-G
FTXG-J FXFQ-P9 VRV® indoor unit
FVXG-K BPMKS967B2
54
the
ue
talog ial Ca
ent Resid
RXYRQ-P
VRV®III heat pump, with connection to stylish indoor units
The minimum piping length between the outdoor unit and the first branch is 5 m. The minimum piping length between the BP box and the indoor unit is 2 m, the maximum length is 15 m. After the first branch, the longest piping length is 50m, or 70m in case the first branch contains only VRV indoor units. The height difference between the outdoor and indoor unit or BP box can be maximum 50 m, 40 m if the outdoor is below the indoors.
5m minimum length
up to 70m maximum
The VRV® heat pump with connection to stylish indoor units offers a total system piping length of 250 m.
15m Level difference between indoor units
50m/40m Level difference between indoor and outdoor units
piping design
2m minimum length 15m maximum length
Connectable indoor units Daikin Emura - Wall mounted unit Wall mounted unit Nexura - Floor standing unit Floor standing unit Flexi type unit Slim concealed ceiling unit Concealed ceiling unit 4-way blow ceiling mounted cassette (600x600) Round flow cassette Ceiling suspended cassette All VRV indoor units in all available classes
15 class
20 class
25 class
35 class
42 class
50 class
60 class
71 class
CTXS15K -
FTXS20K FTXS20J -
FTXG25JW/A FTXS25K FTXS25J FVXG25K FVXS25F FLXS25B FDXS25E FFQ25B9V -
FTXG35JW/A CTXS35K FTXS35J FVXG35K FVXS35F FLXS35B FDXS35E FBQ35C FFQ35B9V FCQG35F FHQ35B
FTXS42J -
FTXG50JW/A FTXS50J FVXG50K FVXS50F FLXS50B FDXS50C FBQ50C FFQ50B9V FCQG50F FHQ50B
FTXS60G FDXS60C FBQ60C FFQ60B9V FCQG60F FHQ60B
FTXS71G -
Heat pump Outdoor unit Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
HP kW kW kW kW
mm kg dBA dBA °CDB °CWB mm mm m m Hz/V A
RXYRQ8P 8 22.4 25.0 5.09 5.56 4.40 4.50 17
RXYRQ10P 10 28.0 31.5 7.11 7.70 3.94 4.09 21 1,680x930x765
187
RXYRQ12P 12 33.5 37.5 9.23 9.44 3.63 3.97 26
RXYRQ14P 14 40.0 45.0 11.40 11.30 3.61 3.98 30
240
316
78 57
RXYRQ16P 16 45.0 50.0 13.50 12.90 3.33 3.88 34 1,680x1,240x765
324 83 63
80 60
58
RXYRQ18P 18 49.0 56.5 15.30 15.30 3.20 3.69 39
-5.0~43.0 -20.0~15.0 R-410A 9.52 19.1
12.7 22.2
15.9 28.6
250 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3N~/50/400 25
55
40
RXYSQ-P8
VRV®III-S heat pump
›› Compact unit yet providing many of the Daikin VRV® III benefits –– High efficiency –– Low noise –– Demand operation –– Automatic charging
Automatic refrigerant charging
›› Two systems in one –– Same outdoor unit can connect either VRV indoor units or Split & SkyAir indoor units
Wide range of indoor units Either connect VRV® indoor units or stylish indoor units as Daikin Emura, Nexura, ...
FCQ-C8 FVXS-F
FTXG-J
BPMKS967B3
BPMKS967B2
FTXS-G
FBQ-C
FTXG-J FVXG-K
BPMKS967B2 FXSQ-P
FXFQ-P9
FXLQ-P
FXLQ-P
FXSQ-P
FXAQ-P
FXFQ-P9
* VRV® indoor units and stylish indoor units cannot be combined.
56
RXYSQ-P8
VRV®III-S heat pump
Flexible piping design The VRV®III-S provides the long piping length possibilities of 300m total piping when using VRV® indoor units (150m actual / 175m equivalent from outdoor to furthest indoor), or 250m total when using Split or SkyAir indoor units (100m total between outdoor and BP boxes, 80m total between BP boxes and indoor units). The level difference between the outdoor unit and the indoor units can be up to 40m, and up to 50m in case of VRV indoor units and installation of outdoor unit above indoor units. After the first branch, the longest piping length is 40m.
40m maximum
15m Level difference between indoor units
40m Level difference between indoor and outdoor units
50m Level difference between indoor and outdoor units
150m Actual piping length
5m minimum length
2m minimum length 15m maximum length
Heat pump Outdoor unit Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure Cooling Nom. level Heating Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
HP kW kW kW kW
mm kg dBA dBA dBA °CDB °CWB mm mm m m m Hz/V A
RXYSQ4P8V1 4 11.2 12.5 2.81 2.74 3.99 4.56 8 (1) / 6 (2)
RXYSQ5P8V1 RXYSQ6P8V1 RXYSQ4P8Y1 RXYSQ5P8Y1 RXYSQ6P8Y1 5 6 4 5 6 14.0 15.5 11.2 14.0 15.5 16.0 18.0 12.5 16.0 18.0 3.51 4.53 2.89 3.61 4.65 3.86 4.57 2.82 3.97 4.70 3.99 3.42 3.88 3.33 4.15 3.94 4.43 4.03 3.83 10 (1) / 8 (2) 13 (1) / 9 (2) 8 (1) / 6 (2) 10 (1) / 8 (2) 13 (1) / 9 (2) 1,345x900x320 1,345x900x320 120 120 66 67 69 66 67 69 50 51 53 50 51 53 52 53 55 52 53 55 -5~46 -5~46 -20~15.5 -20~15.5 R-410A R-410A 9.52 9.52 15.9 (1) / 19.1 (2) 15.9 (1) / 19.1 (2) 19.1 (1)(2) 15.9 (1) / 19.1 (2) 15.9 (1) / 19.10 (2) 19.1 (1)(2) 150 150 300 (1) / 115 (2) 300 (1) / 135 (2) 300 (1) / 145 (2) 300 (1) / 115 (2) 300 (1) / 135 (2) 300 (1) / 145 (2) 50 (1) / 40 (2) (Outdoor unit in highest position) / 30 (Indoor unit in highest position) 50 (1) / 40 (2) (Outdoor unit in highest position) / 30 (Indoor unit in highest position) 1N~/50/220-240 3N~/50/380-415 32.0 16.0
(1) In case VRV indoor units are connected | (2) In case RA indoor units are connected
57
RQCEQ-P RQYQ-P
Replacement VRV
THE DAIKIN SOLUTION TO R-22 PHASE-OUT Replace your R-22 / R-407C outdoor unit with R-410A technology, but keep your refrigerant piping and in some cases your indoor units1.
replace
1. 2. 3. 4.
Replace outdoor unit Replace BS-boxes (in case of H/R) Replace indoor units (check with your local dealer if needed) The system will automatically clean the piping & charge the correct amount of R-410A refrigerant
KEEP replace * When R-22 indoors are K-series or later, it is possible to keep the indoor units.
replace*
TECHNOLOGIES OF VRV®III-Q? Pressure
A
3.3 MPa
}
3.8 MPa
}
REDUCED PRESSURE As R-22 VRV® systems used to work on a lower pressure than R-410A systems / thus the copper refrigerant piping was also designed for these lower pressures. Therefore the Replacement VRV® (VRV®III-Q) must operate at lower pressures than the standard VRV®III series. However thanks to the sub cool circuit a high efficiency level can be kept even with the lower pressures.
B
~
~
Enthalpy
A Decompression to 3.3MPa(s) R-22 existing piping can be used B Extra sub cool circuit high COP
REFRIGERANT PIPE CLEANING When replacing an air conditioning system, the piping is normally replaced as well since traces of old refrigerant and oil mixed with the oil and refrigerant of the new system can cause the equipment to malfunction.
the outdoor unit and the contamination is deposited in the outdoor unit. Daikin is the first manufacturer in the industry to develop this combination of automatic charging and refrigerant pipe cleaning function.
In order to allow re-use of existing R-22 piping with an R-410A system Daikin developed a technology to capture and retain the contamination left in the refrigerant piping. The refrigerant including the remaining oil from the R-22 system is filtered in
Indoor Temperature sensor
Change over valve
Pressure sensor
Anti-reverse valve
Temperature sensor
Catcher
Contamination is collected by the power of the refrigerant gas
58
RQCEQ-P RQYQ-P
Replacement VRV
INCREASED EFFICIENCY Upgrading an old R-22 system to a Replacement VRV® system will result in increased system efficiency. Efficiency gains of more than 25% can be realized, by virtue of technological developments in heat pump technology and the more efficient R-410A refrigerant. Increased energy efficiency equals lower energy consumption, subsequent lower energy costs and lower CO2 emissions. EER of a 10 HP system
COP of a 10 HP system
4.50
4.50
4.00
4.00
3.50
3.50
3.00
2.00
3.00
3.98
2.50
2.37
3.10
1.50 R-22 R-407C
2.50
4.00 3.00
3.10
2.00 1.50 R-22 R-407C
R-410A VRVIII-Q
40% more efficient
R-410A VRVIII-Q
25% more efficient
R-22: RSXY10KA7 | R-407C: RSXYP10L7 | R-410A: RQYQ10P
R-22: RSXY10KA7 | R-407C: RSXYP10L7 | R-410A: RQYQ10P
ENVIRONMENTAL AWARENESS R-410A not only has a zero ozone depletion potential, it is also proven to be more energy efficient than R-22. FAST INSTALLATION It is not necessary to remove the existing piping and even the indoor units can remain (depending on type of indoor unit). The outdoor unit automatically charges the refrigerant and cleans the refrigerant piping. This unique Daikin feature makes the installation time even shorter.
INCREASE CAPACITY Cooling loads often increase subsequent to the initial installation of the air conditioning system. The Replacement VRV®(VRV®III-Q) enables system capacity to be increased without changing the refrigerant piping (depending on system characteristics).
Example: replace a 10HP VRV® with a 16HP Replacement VRV® unit
10 HP
1.
LIMITED AND PLANNED-DOWNTIME As the refrigerant piping can be maintained the installation is less intrusive and less time consuming than for a completely new system. Moreover, downtime can be carefully planned: whereas if a problem occurs when not enough reclaimed R-22 is available, a long and unplanned downtime can be the result. LIMITED AND PHASED INVESTMENT COST It is possible to spread the various stages of replacement over a certain period of time because the indoor units can remain in most cases. The air conditioning replacement therefore, can be incorporated in the general refurbishment schedule of the building and the investment cost can be spread. A further reduction in installation cost can be achieved by maintaining the old refrigerant copper pipe work. 59
16 HP
2.
1. Keep main piping
2. Add indoor units
NO RESTRICTIONS ON SYSTEM HISTORY As a result of the combined automatic charging and refrigerant pipe cleaning function, it is possible to ensure a clean piping network, even when a compressor breakdown has previously occurred.
RQCEQ-P RQYQ-P
Replacement VRV
›› Get rid of R22 easily! –– Keep old R22 piping –– Keep old indoor units and controllers –– (Daikin K-series and newer in case of heat pump systems) –– Low installation costs –– Low disruption caused by the installation –– High reliability thanks to newest technology
Automatic refrigerant charging High ESP Fans SHR =1
High sensible mode
›› Reduce operating costs by up to 40% ›› Applicable also on non-Daikin R22 VRF systems
Heat recovery Outdoor system System
Outdoor unit module 1 Outdoor unit module 2 Outdoor unit module 3 Outdoor unit module 4
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Discharge gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA) Outdoor unit module HeightxWidthxDepth Dimensions Unit Weight Unit Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Power supply Phase/Frequency/Voltage
HP kW kW kW kW
dBA mm mm mm m m m Hz/V A
RQCEQ280PY1 RQCEQ360PY1 RQCEQ460PY1 RQCEQ500PY1 RQCEQ540PY1 RQCEQ636PY1 RQCEQ712PY1 RQCEQ744PY1 RQCEQ816PY1 RQCEQ848PY1 RQEQ140P RQEQ180P RQEQ140P RQEQ180P RQEQ212P RQEQ140P RQEQ180P RQEQ212P RQEQ140P RQEQ180P RQEQ140P RQEQ180P RQEQ212P RQEQ180P RQEQ212P RQEQ180P RQEQ212P RQEQ180P RQEQ212P RQEQ212P 10 13 16 18 20 22 24 26 28 30 28.0 36.0 45.0 50.0 54.0 63.6 71.2 74.4 81.6 84.8 32.0 40.0 52.0 56.0 60.0 67.2 78.4 80.8 87.2 89.6 7.04 10.3 12.2 13.9 15.5 21.9 21.2 23.3 27.1 29.2 8.00 10.7 13.4 14.7 16.1 17.7 20.7 21.2 23.1 23.6 3.98 3.48 3.77 3.61 3.48 2.90 3.36 3.19 3.01 2.90 4.00 3.72 3.89 3.80 3.72 3.79 3.80 3.81 3.77 3.79 21 28 34 39 43 47 52 56 60 64 57 61 62 63 64 63 64 65 66 9.52 12.7 15.9 19.1 22.2 25.4 28.6 34.9 19.1 22.2 25.4 28.6 120 300 50 (Outdoor unit in highest position) 3~/50/400 30 40 50 60 70 80 90 RQEQ140P
mm kg dBA °CDB °CWB
RQEQ180P 1,680x635x765 175
54
58 -5~43 -20~15 R-410A 3~/50/380-415
Hz/V
60
RQEQ212P 179 60
RQCEQ-P RQYQ-P
Replacement VRV
Heat pump Outdoor unit System Capacity range Cooling capacity Heating capacity Power input - 50Hz
Outdoor unit module 1 Nom. Nom. Cooling Heating
Nom. Nom.
EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
Outdoor unit System
mm kg dBA dBA 째CDB 째CWB mm mm m m m Hz/V A
Outdoor unit module 1 Outdoor unit module 2
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Current - 50Hz Maximum fuse amps (MFA) Outdoor unit System
HP kW kW kW kW
HP kW kW kW kW
dBA mm mm m m m A
RQYQ140P RQYQ140P 5 14.0 16.0 3.36 3.91 4.17 4.09 10 1,680x635x765 175
RQYQ8P RQYQ8P 8 22.4 25.0 5.24 6.42 4.27 3.89 17
54.0
57.0
HP kW kW kW kW
230
RQYQ12P RQYQ12P 12 33.5 37.5 10.10 10.20 3.32 3.68 26
RQYQ14P RQYQ16P RQYQ14P RQYQ16P 14 16 40.0 45.0 45.0 50.0 11.6 13.6 12.2 13.6 3.45 3.31 3.69 3.68 30 34 1,680x1,240x765 381
284 58.0
60.0 -5~43 -20~15.5 R-410A
9.52 19.1
15.9
12.7 28.6
22.2 150 300 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 3~/50/380-415 25
15
RQYQ18PY1 RQYQ20PY1 RQYQ8P RQYQ10P 18 20 50.4 55.9 56.5 62.5 12.9 15.4 15.1 16.7 3.91 3.63 3.74 39 43 61 62
RQYQ22PY1 RQYQ10P RQYQ12P 22 61.5 69.0 17.8 18.8 3.46 3.67 47
RQYQ24PY1 RQYQ12P
RQYQ26PY1 RQYQ10P
24 67.0 75.0 20.2 20.4 3.32 3.68 52
26 73.0 81.5 21.3 22.2 3.43 3.67 56
35
RQYQ28PY1 RQYQ30PY1 RQYQ32PY1 RQYQ12P RQYQ14P RQYQ16P RQYQ16P 28 30 32 78.5 85.0 90.0 87.5 95.0 100 23.7 25.2 27.2 23.8 25.8 27.2 3.31 3.37 3.31 3.68 60 64 63
15.9
19.1
28.6
34.9 150 300 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 50 60
45 RQYQ34PY1
RQYQ38PY1
RQYQ42PY1 RQYQ10P
34 96.0 108 26.9 29.4 3.57
38 107 119 31.4 32.4 3.41
42 118 132 34.9 35.8 3.38 3.69
Outdoor unit module 1 Outdoor unit module 2
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Current - 50Hz Maximum fuse amps (MFA)
RQYQ10P RQYQ10P 10 28.0 31.5 7.64 8.59 3.66 3.67 21 1,680x930x765
RQYQ36PY1 RQYQ10P RQYQ10P 36 101 113 28.9 30.8 3.49 3.67
RQYQ40PY1 RQYQ12P RQYQ12P 40 112 125 33.8 34.0 3.31 3.68
70
RQYQ44PY1 RQYQ46PY1 RQYQ48PY1 RQYQ12P RQYQ14P RQYQ16P RQYQ16P 44 46 48 124 130 135 138 145 150 35.3 38.8 40.8 36.0 39.4 40.8 3.51 3.35 3.31 3.83 3.68
64 dBA mm mm m m m A
64
65 19.1
34.9
90
(1) Field setting
61
41.3 150 300 50 (Outdoor unit in highest position) / 40 (Indoor unit in highest position) 100
110
RWEYQ-P RWEYQ-PR
SHR =1
High sensible mode
VRV®III water cooled standard & geothermal series
›› First geothermal-sourced VRF system in the world! –– Works with water-glycol temperatures as low as -10°C, making the use of economically sized geothermal collectors possible –– Extremely efficient – COP over 3.4 even with -10°C water temperature, and over 5 with +10°C water temperature ›› Great solution for high-rise buildings – no need to cover big elevation differences with refrigerant piping ›› Unified outdoor unit both for heat pump and heat recovery applications
62
RWEYQ-P RWEYQ-PR
VRV®III water cooled standard & geothermal series
High energy efficiencies results from 2-stage heat recovery VRV®-W benefits from a 2-stage heat recovery facility. The first stage is achieved within the refrigerant system and applies to heat recovery units only. Heat exhausted from indoor units in cooling mode is merely transferred to units in areas requiring heating, maximising energy efficiency and reducing electricity costs.
Heat recovery also available on heat pump units Second stage heat recovery is achieved within the water loop between the water cooled outdoor units. Two-stage heat recovery substantially improves energy efficiency and represents an ideal solution to the requirements of modern office buildings, in which some areas may require cooling even in winter, depending on the degree of sunshine at the time and the number of individuals in the room.
Heat recovery between indoor units
Heat recovery between outdoor units (Heat recovery and heat pump)
All indoor units in cooling mode
Cooling tower (Closed type), boiler
Heat rejected to loop
VRV®-W
VRV®-W Indoor units mainly cooling, partly heating Heat partly rejected to loop
Heat rejected to loop VRV®-W
VRV®-W Full Heat Recovery
Heat rejected to loop VRV®-W VRV®-W Indoor units mainly heating, partly cooling Heat absorbed from loop
Partly heat absorption from loop
VRV®-W VRV®-W All indoor units in heating mode Heat absorption from loop
Heat absorbed from loop
VRV®-W
63
RWEYQ-P RWEYQ-PR
VRV®III water cooled standard & geothermal series
Wide operation range Standard water cooled outdoor units have a wide operation range of between 10°C & 45°C inlet water temperature, both in heating and cooling. For the geothermal series the operation range is extended even more, down to -10°C* in heating and 6°C in cooling mode. * Ethylene glycol should be added to the water when the water inlet temperature is below 5°C STANDARD SERIES • HEAT RECOVERY • HEAT PUMP
GEOTHERMAL SERIES • HEAT RECOVERY • HEAT PUMP
50° 40°
Heating 45°C
Cooling 45°C
Heating 45°C
Cooling 45°C
30° 20° 10°
10°C
10°C 6°C
0° -10°
-10°C
Flexible piping design
Flexible water piping Water cooled VRV® uses water as its heat source, so it is optimal for large buildings, including tall, multi-storey buildings, because the system can tolerate water pressure of up to 1.96 MPa.
Actual piping length between the VRV®-W and indoor units: 120m (Equivalent piping length: 140m)
Furthermore, if the currently installed heat source’s water temperature is between 10°C and 45°C, it may be possible to use the existing water pipe work and heat source. This alone makes it an ideal system solution for building refubishment projects. Because the system is water cooled, outdoor air temperature does not affect its heating capacity. In addition, water cooling means no defrost operation is required, and the resultant rapid start-up time assures quick and comfortable heating, even in cold environment.
Water piping Refrigerant piping
Level difference between indoor units: 15m
VRV®-W
Level difference between the VRV®-W and indoor units: 50m if the VRV®-W is above 40m if the VRV®-W is below
Long refrigerant piping length
VRV®-W
Considerable flexibility is available within the refrigerant circuit since up to 120m actual piping length and 50m* (if the VRV®-W outdoor unit is above the indoor units) in height can exist between the VRV®-W outdoor units and indoor units. Water piping does not intrude on the occupied spaces, so there are no leakage problems.
Indoor installation Water piping length depends on the heat source equipment
* 40m if the VRV®-W outdoor unit is below the indoor units.
64
RWEYQ-P RWEYQ-PR
VRV®III water cooled standard & geothermal series
Heat pump & Heat recovery – standard series Outdoor unit System Capacity range Cooling capacity Heating capacity Power input - 50Hz
Outdoor unit module 1 Nom. Nom. Cooling Heating
Nom. Nom.
EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Inlet water Cooling Min.~Max. temperature Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Discharge gas OD Water Inlet/Outlet Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
HP kW kW kW kW
RWEYQ8P RWEYQ8P 8 22.4 25.0 4.55 4.24 4.89 5.81 17
mm kg dBA dBA °CDB °CWB mm mm mm m m m Hz/V A
RWEYQ10P RWEYQ10P 10 26.7 31.5 6.03 6.05 4.14 5.08 21 1,000x780x550
149
150 -
50
51 10~45 10~45 R-410A 9.52
19.1 (1) 22.2 (1) 15.9 (2) / 19.1 (3) 19.1 (2) / 22.2 (3) PT1 1/4B internal thread/PT1 1/4B internal thread 120 300 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3~/50/380-415 25
(1) In case of heat pump system, gas pipe is not used | (2) In case of heat recovery system | (3) In case of heat pump system
Outdoor unit System
Outdoor unit module 1 Outdoor unit module 2 Outdoor unit module 3
Capacity range Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. EER COP Maximum number of connectable indoor units Sound pressure level Cooling Nom. Piping Liquid OD connections Gas OD Discharge gas OD Current - 50Hz Maximum fuse amps (MFA)
HP kW kW kW kW
dBA mm mm mm A
RWEYQ16P RWEYQ18P RWEYQ20P RWEYQ24P RWEYQ26P RWEYQ28P RWEYQ30P RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P RWEYQ8P RWEYQ10P 16 18 20 24 26 28 30 44.8 49.1 53.4 67.2 71.5 75.8 80.1 50.0 56.5 63.0 75.0 81.5 88.0 94.5 9.10 10.6 12.1 13.7 15.1 16.6 18.1 8.48 10.3 12.1 12.7 14.5 16.3 18.2 4.92 4.63 4.41 4.91 4.74 4.57 4.43 5.87 5.48 5.21 5.91 5.62 5.40 5.19 34 36 53 54 55 56 12.7 15.9 19.1 28.6 (1) 34.9 (1) 22.2 (2) / 28.6 (3) 22.2 (2) / 28.6 (3) 22.2 (2) / 28.6 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3) 28.6 (2) / 34.9 (3) 35 45
(1) In case of heat pump system, gas pipe is not used | (2) In case of heat recovery system | (3) In case of heat pump system
Heat pump & Heat recovery – geothermal series Outdoor unit System Capacity range Cooling capacity Heating capacity Power input - 50Hz
Outdoor unit module 1 Nom. Nom. Cooling Heating
Nom. Nom.
EER COP Maximum number of connectable indoor units HeightxWidthxDepth Dimensions Unit Weight Unit Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Inlet water Cooling Min.~Max. temperature Heating Min.~Max. Refrigerant Type Piping Liquid OD connections Gas OD Discharge gas OD Water Inlet/Outlet Piping length OU - IU Max. Total piping length System Actual Level difference OU - IU Power supply Phase/Frequency/Voltage Current - 50Hz Maximum fuse amps (MFA)
HP kW kW kW kW
RWEYQ8PR RWEYQ8PY1R 8 22.4 25.0 4.58 4.30 4.89 5.81 17
mm kg dBA dBA °CDB °CWB mm mm mm m m m Hz/V A
RWEYQ10PR RWEYQ10PY1R 10 26.1 31.5 6.30 6.20 4.14 5.08 21 1,000x780x550
149
150 -
50
51 6~45 -10~45 R-410A 9.52
19.1 (1) 22.2 (1) 15.9 (2) / 19.1 (3) 19.1 (2) / 22.2 (3) PT1 1/4B internal thread/PT1 1/4B internal thread 120 300 50 (Outdoor unit in highest position) /40 (Indoor unit in highest position) 3~/50/380-415 25
(1) In case of heat pump system, gas pipe is not used | (2) In case of heat recovery system | (3) In case of heat pump system
65
BSVQ-P8
Individual branch selector for VRV heat recovery
›› Allows individual cool / heat switching for 1 group of indoor units ›› Maximum design flexibility because individual and multi boxes can be combined in one system ›› Low built-in height ›› No drain piping needed ›› Allows multi tenant applications (option PCB required)
Indoor unit Power input
Cooling Nom. Heating Nom. Maximum number of connectable indoor units Maximum capacity index of connectable indoor units Casing Material HeightxWidthxDepth Dimensions Unit Weight Unit Piping Outdoor unit Liquid Type/OD connections Gas Type/OD Discharge gas Type/OD Indoor unit Liquid Type/OD Gas Type/OD Sound absorbing thermal insulation Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
BSVQ100P8
BSVQ160P8 0.005 0.005
kW kW 6 20<x≤100 mm kg mm mm mm mm mm Hz/V A
BSV4/6Q-PV
BSVQ250P8
8 100<x≤160 Galvanised steel plate 207x388x326
160<x≤250
12
15 Brazing connection/9.5 Brazing connection/15.9 Brazing connection/15.9 Brazing connection/22.2 Brazing connection/12.7 Brazing connection/12.7 Brazing connection/19.1 Brazing connection/9.5 Brazing connection/9.5 Brazing connection/15.9 Brazing connection/22.2 Foamed polyurethane, frame resisting needle felt 1~/50/220-240 15
Multi branch selector for VRV heat recovery
›› Faster installation thanks to a reduced number of brazing points and wiring ›› Allows individual cool / heat switching for up to 4/6 groups of indoor units ›› Maximum design flexibility because individual and multi boxes can be combined in one system ›› Low built-in height ›› No drain piping needed Indoor unit Power input
Cooling Nom. kW Heating Nom. kW Maximum number of connectable indoor units Maximum number of connectable indoor units per branch Number of branches Maximum capacity index of connectable indoor units Maximum capacity index of connectable indoor units per branch Casing Material HeightxWidthxDepth mm Dimensions Unit Weight Unit kg Piping Outdoor unit Liquid Type/OD mm connections Gas Type/OD mm Discharge gas Type/OD mm Indoor unit Liquid Type/OD mm Gas Type/OD mm Sound absorbing thermal insulation Power supply Phase/Frequency/Voltage Hz/V Maximum Fuse Amps (MFA) A
BSV4Q100PV 0.020 0.020 24
BSV6Q100PV 0.030 0.030 36 6
4 400
6 600 100 Galvanised steel plate
209x1,053x635 60 Brazing connection/12.7
209x1,577x635 89 Brazing connection/15.9 Brazing connection/28.6
Brazing connection/19.1
Brazing connection/28.6 Brazing connection/9.5 Brazing connection/15.9 Foamed polyurethane, frame resisting needle felt 1~/50/220-240 15
67
INdoor Units As many as 64 separate indoor units can be operated from the single refrigerant circuit of a 54 HP VRV® heat pump
NO LESS THAN 26 DIFFERENT STYLISH AND ELEGANT MODELS IN 116 DIFFERENT VARIANTS — all designed to maximise comfort, minimise operating noise and simplify installation and servicing. system. In fact, the Daikin VRV® indoor unit range, one of the widest on the market, currently comprises
VRV® indoor units are modern, technologically advanced and come in ceiling mounted cassette, concealed ceiling, ceiling suspended, wall mounted and floor standing models. The Roundflow cassette now includes an optional auto cleaning filter, which automatically cleans itself daily, leading to yearly energy savings of up to 10%. Dust from the filter is collected in the unit for removal by simple vacuum cleaning.
Designed to fit rooms of any size and shape, Daikin indoor units are also user friendly, quiet running, ultra reliable, easy to control and supply users with that relaxing ‘extra something’ to the indoor climate.
68
BYCQ140CG
Auto cleaning decoration panel, option for round flow cassette
DAIKIN INTRODUCES FIRST AUTO CLEANING CASSETTE TO EUROPEAN MARKET Daikin launches a new decoration panel for the round flow cassette, equipped with a special filter, which automatically cleans itself once a day. All dust coming from this filter is stored in the indoor unit and can be removed with a normal vacuum cleaner. With this decoration panel energy and maintenance costs will be lower and comfort will be increased
HIGHER EFFICIENCY AND COMFORT FROM DAILY AUTO CLEANING OF THE FILTER ➔ Energy savings up to 50% can be achieved (based on test site in Wolverhampton, UK) With a standard decoration panel the energy consumption of the unit increases slowly because dust accumulates in the filter. After the filter is cleaned the energy consumption is back at the level of installation. With the auto cleaning decoration panel the filter is cleaned everyday and therefore the energy consumption remains constant, resulting in an energy saving exceeding 15% compared to yearly filter cleaning. Depending on local circumstances (e.g. dirty environment), the energy savings can reach up to 50%.
Electricity consumption ratio (%)
160
EASY REMOVAL OF DUST WITH A VACUUM CLEANER WITHOUT OPENING THE UNIT 160
›› ›› ›› ››
130
Accumulation of dirt in the filter causes energy consumption to increase
130
›› ››
100
Dust is stored in dust box Emptying the dust box can be done with a vacuum cleaner No rearrangement of shop interior etc to access the unit Only a vacuum cleaner is required, no ladder or other equipment Qualified personnel is not necessary No manual cleaning – not required to touch the dust
100
Day 1: equal energy consumption After 1 year: > 30% increase in energy consumption => An average increase of 15% in energy consumption on a yearly basis
0
0.5 0
0.5
1 1
1.5 1.5
Operation years
2
LOWER MAINTENANCE COSTS THANKS TO AUTO CLEANING FUNCTION
2
Filter is never cleaned Filter is cleaned once a year Filter is cleaned every day
›› ››
70
Less time needed for filter maintenance Less qualified personnel required
FXFQ-P9
Round flow cassette
›› Round-flow discharge –– 360° out-blow of air, unique in the industry ›› Choice of three decoration panels –– Standard panel with grey discharge –– Standard panel with white discharge –– Auto-cleaning panel – unique in the industry ›› Low noise –– 28 dB(A) on low fan speed till size 63 ›› Very low installation height –– 214 mm for units up to size 63 ›› Well equipped: –– Drain pump standard (850 mm lift from ceiling level) –– Fresh air intake (either direct or with kit)
FLEXIBLE AIR-FLOW CONFIGURATION Round flow
4-Way blow
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. HeightxWidthxDepth Dimensions Unit Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Sound power level Cooling Nom. Sound pressure Cooling High/Low level Heating High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm kg
mm kg m³/min m³/min dBA dBA dBA mm Hz/V A
3-Way blow
FXFQ20P9 2.2 2.5
FXFQ25P9 2.8 3.2 0.053 0.045
2-Way blow
FXFQ32P9 3.6 4.0
FXFQ40P9 4.5 5.0 0.063 0.055 204x840x840
FXFQ80P9 FXFQ100P9 FXFQ125P9 9.0 11.2 14.0 10.0 12.5 16.0 0.120 0.173 0.258 0.108 0.176 0.246 246x840x840 288x840x840 20 21 24 26 BYCQ140CW1 / BYCQ140CW1W / BYCQ140CGW1 Pure White(RAL 9010) 50x950x950 / 50x950x950 / 130x950x950 5.5 / 5.5 / 11.5 12.5/9.0 13.5/9.0 15.5/10.0 16.5/11.0 23.5/14.5 26.5/17.0 33.0/20.0 12.5/9.0 13.5/9.0 15.0/9.5 17.5/12.0 23.5/14.5 28.0/17.5 33.0/20.0 49 50 51 52 55 58 61 31/28 32/28 33/28 34/29 38/32 41/33 44/34 31/28 32/28 33/28 36/30 38/32 42/34 44/34 R-410A 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25) 1~/50/60/220-240/220 16
71
FXFQ50P9 5.6 6.3 0.083 0.067
FXFQ63P9 7.1 8.0 0.095 0.114
FXZQ-M9
4-way blow ceiling mounted cassette
›› Ideal for small offices –– Available in class 15 capacity size ›› Compact casing –– Fits in standard European ceiling tiles ›› Uniform outlook –– Same decoration panel for all unit sizes ›› Low noise –– < 26 dB(A) on low fan speed till size 32 ›› Easy service –– Access to electrical box through suction grille ›› Well equipped: –– Drain pump standard (750 mm lift from ceiling level) –– Fresh air intake (direct, connection flange available as accessory kit)
FLEXIBLE AIR-FLOW CONFIGURATION 4-Way blow
3-Way blow
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling High/Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW
2-Way blow
FXZQ15M9 1.7 1.9 0.073 0.064
FXZQ20M9 2.2 2.5
FXZQ25M9 2.8 3.2 0.073 0.064
mm kg BYFQ60BW1 mm kg m³/min dBA dBA mm Hz/V A
8.1/7 -/46 29/25
9.0/7.0 -/47 30/25
6.35/12.7/VP20 (I.D. 20/O.D. 26)
72
FXZQ32M9 3.6 4.0 0.076 0.068
Unpainted 286x575x575 18 BYFQ60B7W1 White 55x700x700 2.7 9.5/7.5 -/49 32/26 R-410A 6.35/12.70/26 1~/50/220-240 15
FXZQ40M9 4.5 5.0 0.089 0.080
FXZQ50M9 5.6 6.3 0.115 0.107
11.0/8.0 -/53 36/28
14.0/10.0 -/58 41/33
FXCQ-M8
2-way blow ceiling mounted cassette
›› Easy service –– Access to electrical box through suction grille –– Easy cleaning thanks to completely flat suction panel and removable swing flaps ›› Comfort and convenience functions –– Ceiling soiling prevention –– Draft prevention ›› Well equipped: –– Drain pump standard (600 mm lift from ceiling level) –– Fresh air intake –– Branch duct connection possibility
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Required ceiling void > Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Sound power level Cooling Nom. Sound pressure Cooling High/Low level Heating High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW
FXCQ20M8 2.2 2.5 0.077 0.044
FXCQ25M8 2.8 3.2
FXCQ32M8 3.6 4.0
FXCQ40M8 4.5 5.0
0.092 0.059
FXCQ50M8 5.6 6.3 0.130 0.097
FXCQ63M8 7.1 8.0 0.161 0.126
305x995x600
305x1,180x600
Unpainted mm mm kg
305x780x600 350 26 BYBC32GJW1
31
32 BYBC50GJW1
35 BYBC63GJW1
White (10Y9/0.5) mm kg m³/min m³/min dBA dBA dBA
53x1,030x680 8 7/5 7/5 45 33/28 33/28
53x1,245x680 8.5 12/9 12/9
9/6.5 9/6.5 50 35/29 35/29
35.0/29.0 35.0/29.0 R-410A 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 1~/50/230 16
mm Hz/V A
73
35.5/30.5 35.5/30.5
53x1,430x680 9.5 16.5/13 16.5/13 52 38/33 38/33 9.52/15.90/VP25 (O.D. 32 / I.D. 25)
FXKQ-MA
Ceiling mounted corner cassette
›› Extremely slim for small ceiling spaces –– Installation height of only 220 mm ›› Versatile application –– Possibility to discharge into a duct –– Can work from ceilings up to 3.8 m high –– Suitable for technical room cooling ›› Easy service –– Access to electrical box through suction grille ›› Well equipped: –– Drain pump standard (500 mm lift from ceiling level) –– Fresh air intake –– Branch duct connection possibility
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. HeightxWidthxDepth Dimensions Unit Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm kg
FXKQ25MA 2.8 3.2
FXKQ32MA 3.6 4.0
FXKQ40MA 4.5 5.0 0.076 0.056
0.066 0.046 215x1,110x710 31 BYK45FJW1
FXKQ63MA 7.10 8.00 0.105 0.085 215x1,310x710 34 BYK71FJW1
White mm kg m³/min dBA dBA mm Hz/V A
70x1,240x800 8.5 11/9
13/10
70x1,440x800 9.5 18/15
40.0/34.0
42.0/37.0
38.0/33.0 R-410A 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 1~/50/60/220-240/220 15
74
9.52/15.9/VP25 (O.D. 32 / I.D. 25)
FXUQ-MA
4-way blow ceiling suspended unit
›› Unique in the industry –– 4-way air distribution without needing a false ceiling – only by Daikin ›› Powerful –– Suitable for ceilings up to 3.8 m high ›› Ideal unit for refurbishment projects –– Requires no false ceiling –– Saves wall space ›› Suitable for technical room cooling ›› Drain pump standard (350 mm lift from ceiling level)
FLEXIBLE AIR-FLOW CONFIGURATION 4-Way blow
3-Way blow
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Sound power level Cooling High/Nom. Sound pressure Cooling High/Low level Heating High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage
Indoor unit Power input Casing Dimensions Weight Piping connections
Cooling Heating Material Unit Unit Outdoor unit Indoor unit
Nom. Nom.
kW kW kW kW
2-Way blow
FXUQ71MA 8.0 9.0 0.180 0.160
FXUQ100MA 11.2 12.5 0.289 0.269 White
mm kg m³/min m³/min dBA dBA dBA
165x895x895 25 19/14 19/14 56/40/35 40/35
230x895x895 31 29/21 29/21 59/43/38 43/38 R-410A 9.52/15.9/I.D. 20/O.D. 26 1~/50/220-240
mm Hz/V
kW kW
BEVQ71MA 0.189 0.169
BEVQ125MA 0.298 0.278
Galvanised steel plate 100x350x225
mm kg Type/OD mm OD/Type Type/OD mm Type/OD mm
Sound absorbing thermal insulation Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
32/23 32/23 60/44/39 44/39
BEVQ100MA
HeightxWidthxDepth Liquid Gas Liquid Gas
FXUQ125MA 14.0 14.0
3.0 Flare connection/9.52 15.9/Flare connection Flare connection/9.52 Flare connection/15.9 Flame and heat resistant foamed polyetherene 1~/50/60/220-240/220 15
Hz/V A
75
3.5
FXHQ-MA
Ceiling suspended unit
›› Powerful and effective –– Wide 100° air discharge –– Suitable for ceilings up to 3.5 m high ›› Easy maintenance –– Electrical box and fan motors can be accessed via the suction opening ›› Ideal unit for refurbishment projects –– Requires no false ceiling –– Saves wall space ›› Suitable for technical room cooling ›› Integrated drain pump available as option (540 mm lift from unit’s top)
POWERFUL AND EFFECTIVE
Coanda effect
100°
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm kg m³/min dBA dBA mm Hz/V A
FXHQ32MA 3.6 4.0 0.111 0.111 195x960x680 24 12/10 36/31 6.35/12.7/VP20 (I.D. 20/O.D. 26)
76
FXHQ63MA FXHQ100MA 7.1 11.2 8.0 12.5 0.115 0.135 0.115 0.135 White (10Y9/0.5) 195x1,160x680 195x1,400x680 28 33 17.5/14 25/19.5 39/34 45/37 R-410A 9.52/15.9/VP20 (I.D. 20/O.D. 26) 1~/50/60/220-240/220 15
FXAQ-P
Wall mounted unit
›› Ideal for small offices or rooms –– Class 15 capacity size coming in 2nd half of 2012 ›› Stylish design in line with Daikin residential range ›› Easy maintenance –– Flat front panel and swing flap can be easily removed and washed –– All service work can be carried out from the front of the unit without taking it off the wall ›› Ideal unit for refurbishment projects –– Requires no false ceiling
NEW Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm kg m³/min dBA dBA mm Hz/V A
*FXAQ15P 1.7 1.9 290x795x238 7/4.5 33/29 R-410A -/-/ 1~/50/220-240 -
FXAQ20P 2.2 2.5 0.019 0.029
FXAQ25P 2.8 3.2 0.028 0.034
7.5/4.5
290x795x238 11 8/5
FXAQ32P FXAQ40P 3.6 4.5 4.0 5.0 0.030 0.020 0.035 0.020 White (3.0Y8.5/0.5)
8.5/5.5
12/9
FXAQ50P 5.6 6.3 0.033 0.039
FXAQ63P 7.1 8.0 0.050 0.060
290x1,050x238 14 15/12
19/14
42.0/36.0
46.0/39.0
35.0/29.0
77
36.0/29.0
37.0/29.0
39.0/34.0 R-410A 6.35/12.7/VP13 (I.D. 13/O.D. 18) 1~/50/220-240 16
*Note: grey cells contain preliminary data
FXDQ-M9
Small concealed ceiling unit
›› Designed for hotel rooms: –– Very compact to fit in the ceiling of the entrance corridor –– 230 x 502 x 652 mm (HxWxD) ›› Versatile installation –– Suction from back or from bottom –– Choice of drain outlet side –– Air filter standard
VERSATILE INSTALLATION
Air suction direction Drain pan
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Required ceiling void > Weight Unit Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Sound power level Cooling Nom. Sound pressure Cooling High/Low level Heating High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm mm kg m³/min m³/min dBA dBA dBA
FXDQ20M9 2.2 2.5
FXDQ25M9 2.8 3.2 0.050 0.050 Unpainted 230x502x652 250 17
6.7/5.2 6.7/5.2
7.4/5.8 7.4/5.8 50 37/32 37/32 R-410A 6.35/12.7/I.D. 21.6, O.D. 27.2 1~/50/230 16
mm Hz/V A
78
FXDQ-P7
Slim concealed ceiling unit
›› Ideal for small offices or hotel rooms –– Available in class 15 capacity size ›› Extremely slim for small ceiling spaces –– Unit height of only 200 mm ›› Improved user comfort –– 3 fan speeds can be selected ›› Versatile installation –– Suction from back or from bottom –– ESP for moderate ducting (>30 Pa) –– Air filter standard ›› Drain pump standard (550mm lift from unit’s top)
VERSATILE INSTALLATION
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Required ceiling void > Weight Unit Fan-Air flow rate - 50Hz Cooling Super high/High/Nom./Low Fan-External static pressure - 50Hz High/Nom. Sound power level Cooling Nom. Sound pressure level Cooling High/Nom./Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm mm kg m³/min Pa dBA dBA mm Hz/V A
FXDQ15P7 1.7 1.9
FXDQ20P7 2.2 2.5 0.086 0.067
FXDQ25P7 2.8 3.2
FXDQ32P7 3.6 4.0 0.089 0.070 Unpainted
FXDQ40P7 4.5 5.0 0.160 0.147
200x700x620
FXDQ50P7 5.6 6.3 0.165 0.152
200x900x620
FXDQ63P7 7.1 8.0 0.181 0.168 200x1,100x620
240 23 7.5/7.0/-/6.4
8.0/7.2/-/6.4
27 10.5/9.5/-/8.5
51 33/31/29
52 34/32/30
30/10 50 32/31/29
R-410A 6.35/12.7/VP20 (I.D. 20/O.D. 26) 1~/50/60/220-240/220 15
/50/60/220-240/220 16
79
28 12.5/11.0/-/10.0 44/15 53 35/33/31
31 16.5/14.5/-/13.0 54 36/34/32 9.52/15.9/VP20 (I.D. 20/O.D. 26)
FXSQ-P FXMQ-P7
Concealed ceiling unit with inverter driven fan
›› DC Inverter Fans – unique technology for unique features –– Automatic air flow adjustment (see below) for easy commissioning –– Finely selectable ESP – from 10 to 15 fan curves available on every unit –– ESP (fan curves) selectable via remote controller – no need to open a service access –– 3 fan speeds selectable by end-user –– Up to 20% lower power consumption compared to units with AC fans ›› Wide capacity range - from 2.2 to 16.0 kW cooling capacity ›› Versatile installation –– Suction from back or from bottom –– ESP for long ducting (70 ~ 200 Pa) –– Air filter standard ›› Well equipped: –– Drain pump standard (625mm lift from unit’s top for FXSQ, 700mm for FXMQ) –– Fresh air intake Test running
VERSATILE INSTALLATION Design
ዘDuct reconstruction ዘChanging motor ዘ
New flow Test running
Test running
ዘDuct reconstruction ዘChanging motor ዘ
Design New flow Test running
Easy installation thanks to automatic air flow adjustment towards nominal air flow: Installation made easier ››
›› ›› ››
After installation, it is possible that the actual duct resistance is lower or higher than expected at time of designing. As a consequence the air flow will be too high or too low. (Example on right shows case with lower duct resistance) Too low air flow can lead to insufficient capacity and reliability problems; too high air flow can lead to discomfort and noise issues With the automatic air flow adjustment function the unit adapts its fan speed automatically in order to reach the nominal air flow (within 10%) Alternatively the installer can manually select a fan curve with the wired remote control. +/- 10%
External static pressure (Pa)
Reduced installation time
Fan characteristic curve Actual duct resistance curve Duct resistance curve at the time of designing Rated air flow Airflow without air flow automatic adjustment Actual airflow
Air flow (m³/min)
80
+/- 10%
FXSQ-P FXMQ-P7
FXSQ-P - Medium static pressure Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Required ceiling void > Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Fan-External static pressure - 50Hz High/Nom. Sound power level Cooling Nom. Sound pressure Cooling High/Low level Heating High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm mm kg
mm kg m続/min m続/min Pa dBA dBA dBA mm Hz/V A
FXSQ20P FXSQ25P 2.2 2.8 2.5 3.2 0.041 0.029
FXSQ32P 3.6 4.0 0.044 0.032
FXSQ40P FXSQ50P FXSQ63P FXSQ80P FXSQ100P FXSQ125P FXSQ140P 4.5 5.6 7.1 9.0 11.2 14.0 16.0 5.0 6.3 8.0 10.0 12.5 16.0 18.0 0.097 0.074 0.118 0.117 0.185 0.261 0.085 0.062 0.106 0.105 0.173 0.249 Unpainted 300x550x700 300x700x700 300x1,000x700 300x1,400x700 350 23 26 35 46 47 BYBS32DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 White (10Y9/0.5) 55x650x500 55x800x500 55x1,100x500 55x1,500x500 3.0 3.5 4.5 6.5 9/6.5 9.5/7 16/11 19.5/16 25/20 32/23 39/28 46/32 9/6.5 9.5/7 16/11 19.5/16 25/20 32/23 39/28 46/32 70/30 100/30 100/40 120/40 120/50 140/50 55 56 63 59 63 61 66 67 32/26 33/27 37/29 37/30 38/32 40/33 42/34 32/26 33/27 37/29 37/30 38/32 40/33 42/34 R-410A 6.35/12.7/VP25 (O.D. 32 / I.D. 25) 9.52/15.9/VP25 (O.D. 32 / I.D. 25) 1~/50/60/220-240/220 16
FXMQ-P7 - High stactic pressure Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Required ceiling void > Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan-Air flow rate Cooling High/Low - 50Hz Heating High/Low Fan-External static pressure - 50Hz High/Nom. Sound power level Cooling High/Nom. Sound pressure Cooling High/Nom./Low level Heating High/Nom./Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm mm kg
mm kg m続/min m続/min Pa dBA dBA dBA mm Hz/V A
FXMQ20P7 FXMQ25P7 2.2 2.8 2.5 3.2 0.049 0.037
FXMQ32P7 3.6 4.0 0.053 0.041
300x550x700
FXMQ40P7 4.5 5.0 0.151 0.139
FXMQ50P7 5.6 6.3 0.110 0.098 Unpainted
300x700x700
FXMQ63P7 7.1 8.0 0.120 0.108 300x1,000x700
FXMQ80P7 9.0 10.0 0.171 0.159
FXMQ100P7 11.2 12.5 0.176 0.164
FXMQ125P7 14.0 16.0 0.241 0.229
300x1,400x700
350 23 BYBS32DJW1
26 35 46 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 White (10Y9/0.5) 55x650x500 55x800x500 55x1,100x500 55x1,500x500 3.0 3.5 4.5 6.5 9/6.5 9.5/7 16/11 18/15 19.5/16 25/20 32/23 39/28 9.0/6.5 9.5/7 16/11 18/15 19.5/16 25/20 32/23 39/28 100/50 160/100 200/100 56/57/65/61/64/67/65/70/33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 R-410A 6.35/12.7/VP25 (I.D. 25/O.D. 32) 9.52/15.9/VP25 (I.D. 25/O.D. 32) 1~/50/60/220-240/220 16
81
FXMQ-MA
Large concealed ceiling unit
›› Powerful units –– ESP up to 270 at nominal air flow –– Nominal air flow up to 4.320 m3/h –– Cooling capacity up to 28 kW –– Heating capacity up to 31.5 kW ›› Intended for central technical room installation
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate - 50Hz Cooling High/Low Fan-External static pressure - 50Hz High/Nom. Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm kg m³/min Pa dBA dBA mm Hz/V A
FXMQ200MA 22.4 25.0 1.294 1.294
FXMQ250MA 28.0 31.5 1.465 1.465 470x1,380x1,100 137
58/50 221/132
72/62 270/191 48/45 R-410A
9.52/19.1/PS1B
9.52/22.2/PS1B 1~/50/60/220-240/220 15
82
FXNQ-P
Concealed floor standing unit
›› Compact –– Only 22 cm deep and 61 cm high ›› Flexible installation –– Floor standing –– Wall mounted (feet can be removed) ›› Ideal for installation within a windowsill ›› The connecting port faces downward, eliminating the need to attach auxiliary piping
Connecting port
Refrigerant piping
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm kg m³/min dBA dBA
FXNQ20P 2.2 2.5
FXNQ25P 2.8 3.2
0.049 0.049 610x930x220 19 7/6
FXNQ32P 3.6 4.0
FXNQ40P 4.5 5.0
FXNQ50P 5.6 6.3
0.090 0.090 610x1,070x220 23 8/6
FXNQ63P 7.1 8.0
0.110 0.110 610x1,350x220 27 11/8.5
14/11
16/12
38/33
39/34
40/35
35/32 R-410A
mm Hz/V A
6.35/12.7/ 1~/50/60/220-240/220 15
83
9.52/15.9/
FXLQ-P
Floor standing unit
›› New stylish design –– Pure white (RAL9010) finish ›› Flexible installation –– Floor standing by wall –– Wall mounted (feet can be removed) –– Free standing (with optional back panel) ›› Remote controller can be easily integrated in the unit
FLEXIBLE INSTALLATION
Optional back panel
Removable feet for wall installation
Indoor unit Cooling capacity Nom. Heating capacity Nom. Power input - 50Hz Cooling Nom. Heating Nom. Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate - 50Hz Cooling High/Low Sound power level Cooling Nom. Sound pressure level Cooling High/Low Refrigerant Type Piping connections Liquid/OD/Gas/OD/Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW mm kg m³/min dBA dBA
FXLQ20P 2.2 2.5
FXLQ25P 2.8 3.2 0.049 0.049
600x1,000x232 27 7/6 35/32
mm Hz/V A
84
FXLQ32P 3.6 4.0
FXLQ40P 4.5 5.0
0.090 0.090 Fresh white (RAL9010) / Dark grey (RAL7011) 600x1,140x232 32 8/6 11/8.5 38/33 R-410A 6.35/12.7/ 1~/50/60/220-240/220 15
FXLQ50P 5.6 6.3
FXLQ63P 7.1 8.000 0.110 0.110
600x1,420x232 38 14/11
16/12
39/34
40/35 9.52/15.9/
HXHD-A
Heating only hydrobox for VRV
›› Hot water production up to 80°C without electrical heaters – completely heat pump based ›› Leaving water temperature control from 25°C to 80°C, with weather-dependent set-point possible ›› Plug&Play thanks to integrated hydronics –– Variable speed water pump (inverter) –– Expansion vessel –– Safety and air purge valves –– And all other required elements ›› Only for REYAQ-P heat recovery systems, no BSVQ box necessary for connecting to the system ›› Wide range of options –– Hot water tanks –– Solar collector solutions 45°C - 75°C
Liquid pipe Gas pipe Discharge gas pipe F1, F2 communication Hot water
Domestic hot water VRV indoor units
25°C - 75°C Air handling unit
Domestic hot water tank
BS-Box
45°C - 75°C Low temp. radiator BS-Box Heating only hydrobox for VRV
VRV heat recovery with connection to heating only hydrobox (REYAQ10-16P)
25°C - 35°C
Under floor heating
Indoor unit Heating capacity Casing
Nom. Colour Material HeightxWidthxDepth Dimensions Unit Weight Unit Sound pressure Nom. level Night quiet mode Level 1 Operation range Heating Ambient Min.~Max. Water side Min.~Max. Domestic hot Ambient Min.~Max. water Water side Min.~Max. Refrigerant Type Refrigerant circuit Gas side diameter Liquid side diameter Water circuit Piping connections diameter Heating water system Water volume Min.~Max. Power supply Phase/Frequency/Voltage Current Recommended fuses
HXHD125A 14.0 Metallic grey Precoated sheet metal 705x600x695 92 42 (1) / 43 (2) 38 (5) -20~20 / 24 (3) 25~80 -20~43 45~75 R-134a 12.7 9.52 G 1” (female) 20~200 1~/50/220-240 20
kW
mm kg dBA dBA °C °C °CDB °C mm mm inch l Hz/V A
(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting
85
EKHTS-AC
Domestic hot water tank
›› Stainless steel domestic hot water tank ›› The indoor unit and domestic hot water tank can be stacked to save space, or installed next to each other, if only limited height is available ›› Available in 200 and 260 liters ›› Heat loss is reduced to a minimum thanks to the high quality insulation ›› At necessary intervals, the indoor unit can heat up the water to 60°C to prevent the risk of bacteria growth ›› Efficient temperature heat-up: from 10°C to 50°C in only 60 minutes
Indoor unit Casing Dimensions Weight Tank
Heat exchanger
EKHTS200AC
Colour Material HeightxWidthxDepth Unit Unit Empty Water volume Material Maximum water temperature Quantity Tube material Face area Internal coil volume
mm kg l °C
m² l
EKHTS260AC Metallic grey Galvanised steel (precoated sheet metal) 2,010x600x695 (Integrated on indoor unit) 2,285x600x695 (Integrated on indoor unit) 70 78 200 260 Stainless steel (EN 1.4521) 75 1 Duplex steel (EN 1.4162) 1.56 7.5
Domestic hot water tank with possibility for solar connection
EKHWP-A
›› Tank designed for connection with thermal solar collectors ›› Available in 300 and 500 liters ›› Large hot water storage tank to provide domestic hot water at any time ›› Heat loss is reduced to a minimum thanks to the high quality insulation ›› Space heating support possible (500l tank only)
Indoor unit Casing Dimensions Weight Tank Heat exchanger
EKHWP300A Colour Material HeightxWidthxDepth Unit Unit Empty Water volume Maximum water temperature Domestic hot Tube material water Face area Internal coil volume Operating pressure Average specifc thermal output Charging Tube material Face area Internal coil volume Average specifc thermal output Auxiliary solar Tube material heating Face area Internal coil volume Average specifc thermal output
EKHWP500A Dust grey (RAL7037) Impact resistant polypropylene
mm kg l °C
1,590x595x615 59 300
m² l bar W/K
5.7 27.8
1,590x790x790 92 500 85 Stainless steel (DIN 1.4404) 5.9 28.4 6
2,795
2,860 Stainless steel (DIN 1.4404)
m² l W/K
2.5 12.3 1,235
m² l W/K
-
3.7 17.4 1,809 Stainless steel (DIN 1.4404)
86
1.0 5 313
EKSRPS
Pump station
›› Save energy and reduce CO2 emissions with a solar system for domestic hot water production ›› Pump station connectable to unpressurised solar system ›› Pump station and control provide the transfer of solar heat to the domestic hot water tank
Indoor unit Mounting HeightxWidthxDepth Dimensions Unit Thermal performance Zero loss collector efficiency η0 Control Type Power consumption Sensor Solar panel temperature sensor Storage tank sensor Return flow sensor Feed temperature and flow sensor Power supply Voltage
EKSRPS3 On side of tank 815x230x142 Digital temperature difference controller with plain text display 2 Pt1000 PTC PTC Voltage signal (3.5V DC) 230
mm % W
V
EKSV/H-P
Solar collector
›› Horizontal and vertical solar collector for domestic hot water production ›› Solar panels can produce up to 70% of the energy needed for hot water production – a major cost saving ›› High efficiency collectors transfer all the short-wave solar radiation into heat as a result of their highly selective coating ›› Easy to install on roof tiles ›› The solar collectors are charged with water only when needed for heating – avoiding the need for ‘anti-freeze’ protection Indoor unit Dimensions Weight Volume Surface
Coating Absorber Glazing Allowed roof angle Operating pressure Stand still temperature Thermal performance
Installed position
Unit Unit
HeightxWidthxDepth
Outer Aperture Absorber
Min.~Max. Max. Max. Zero loss collector efficiency η0 Heat loss coefficient a1 Temperature dependence of the heat loss coefficient a2 Thermal capacity Incident angle modifier AM at 50°
mm kg l m² m² m²
° bar °C % W/m².K W/m².K² kJ/K
EKSV26P 2,000x1,300x85
EKSH26P 1,300x2,000x85 43
1.7
2.1 2.601 2.364 2.354 Micro-therm (absorption max.96%, Emission ca. 5% +/-2%) Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate Single pane safety glass, transmission +/- 92% 15~80 6 200 78.7 4.270 0.0070 6.5 0.94 Vertical Horizontal
87
VAM-FA
Heat reclaim ventilation
Clean outdoor air Total heat exchanged foul air
Foul indoor air
Total heat exchanged clean air
›› Energy saving ventilation by recovery of indoor unit heat/cold ›› Free cooling when outdoor temperature is below indoor temperature (eg. during night time) ›› Wide range of units: air flow rate from 150 up to 2,000 m³/h ›› Specially developed heat exchange element with High Efficiency Paper (HEP) ›› No drain piping needed ›› Can operate in over- and under pressure
High Efficiency Paper Outdoor
Indoor
30.6°C 62% RH
RH: Relative Humidity SA: Supply Air (to room) RA: Return Air (from room)
SA 27.4°C 63% RH Temperature and humidity RA 26°C 50% RH
32°C 70% RH
SA Integrallyformed liner RA
Integrally-formed liner
Ventilation Ultra high Power input - 50Hz Heat exchange mode Nom. Ultra high Bypass mode Nom. Temperature exchange efficieny - 50Hz Ultra high Enthalpy exchange Cooling Ultra high efficieny - 50Hz Heating Ultra high Operation mode Heat exchange system Heat exchange element HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate Heat exchange mode Ultra high - 50Hz Bypass mode Ultra high Fan-External static pressure - 50Hz Ultra high Heat exchange mode Ultra high Sound pressure level - 50Hz Bypass mode Ultra high Operation range Min. Max. Relative humidity Connection duct diameter Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW % % %
mm kg m³/h m³/h Pa dBA dBA °CDB °CDB % mm Hz/V A
VAM150FA 0.116 0.116 74
VAM250FA 0.141 0.141 72
VAM350FA VAM500FA VAM650FA VAM800FA VAM1000FA VAM1500FA VAM2000FA 0.194 0.212 0.380 0.451 0.469 0.864 0.953 0.194 0.212 0.380 0.451 0.469 0.864 0.953 75 74 75 58 61 58 60 61 64 65 62 63 65 66 Heat exchange mode / Bypass mode / Fresh-up mode Air to air cross flow total heat (sensible + latent heat) exchange Specially processed non-flammable paper 364x1,004x1,156 726x1,514x868 726x1,514x1,156 285x776x525 301x828x816 364x1,004x868 24 33 48 61 132 158 150 250 350 500 650 800 1,000 1,500 2,000 150 250 350 500 650 800 1,000 1,500 2,000 69 64 98 93 137 157 137 27 / 28.5 28 / 29 32 / 34 33 / 34.5 34.5 / 35.5 36 / 37 36 / 37 39.5 / 41.5 40 / 42.5 27 / 28.5 28 / 29 32 / 34 33.5 / 34.5 34.5 / 35.5 36 / 37 36 / 37 40.5 / 41.5 40 / 42.5 -15 50 80% or less 100 150 200 250 350 1~/50/60/220-240/220 15
89
VKM-G(M)
›› ›› ›› ›› ›› ››
Heat reclaim ventilation, humidification and air processing
Creates a high quality indoor environment by pre conditioning incoming fresh air Humidification of incoming air maintains a comfortable indoor humidity level, even during heating Energy saving ventilation by recovery of indoor unit heat/cold Free cooling when outdoor temperature is below indoor temperature (eg. during night time) Specially developed heat exchange element with High Efficiency Paper (HEP) Can operate in over- and under pressure
Ventilation & DX coil Ultra high Power input - 50Hz Heat exchange mode Nom. Ultra high Bypass mode Nom. Fresh air Cooling conditioning load Heating Temperature exchange efficiency - 50Hz Ultra high Enthalpy exchange efficiency - 50Hz Cooling Ultra high Operation mode Heat exchange system Heat exchange element HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate Heat exchange mode Ultra high - 50Hz Bypass mode Ultra high Fan-External static pressure - 50Hz Ultra high Heat exchange mode Ultra high Sound pressure level - 50Hz Bypass mode Ultra high Operation range Around unit Supply air Return air Connection duct diameter Piping Liquid OD connections Gas OD Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA) Ventilation, DX coil & humidification Ultra high Power input - 50Hz Heat exchange mode Nom. Ultra high Bypass mode Nom. Fresh air Cooling conditioning load Heating Temperature exchange efficiency - 50Hz Ultra high Enthalpy exchange efficiency - 50Hz Cooling Ultra high Operation mode Heat exchange system Heat exchange element Humidifier System HeightxWidthxDepth Dimensions Unit Weight Unit Fan-Air flow rate Heat exchange mode Ultra high - 50Hz Bypass mode Ultra high Fan-External static pressure - 50Hz Ultra high Heat exchange mode Ultra high Sound pressure level - 50Hz Bypass mode Ultra high Operation range Around unit Supply air Return air Connection duct diameter Piping Liquid OD connections Gas OD Water supply Drain Power supply Phase/Frequency/Voltage Maximum Fuse Amps (MFA)
kW kW kW kW % %
mm kg m³/h m³/h Pa dBA dBA °CDB °CDB °CDB mm mm mm
VKM50G 0.560 0.560 4.71 5.58 76 64
VKM80G 0.620 0.620 7.46 8.79 78 66 Heat exchange mode / Bypass mode / Fresh-up mode Air to air cross flow total heat (sensible + latent heat) exchange Specially processed non-flammable paper 387x1,764x1,214 109 750 750 170 40 / 41 / 41.5 40 / 41 / 41.5 0°C~40°CDB, 80% RH or less -15°C~40°CDB, 80% RH or less 0°C~40°CDB, 80% RH or less 250 6.35 12.7 PT3/4 external thread 1~/50/220-240 15
387x1,764x832 96 500 500 180 38 / 38.5 / 39 38 / 38.5 / 39
200
Hz/V A
kW kW kW kW % %
mm kg m³/h m³/h Pa dBA dBA °CDB °CDB °CDB mm mm mm mm
VKM50GM 0.560 0.560 4.71 5.58 76 64
VKM80GM 0.620 0.620 7.46 8.79 78 66 Heat exchange mode / Bypass mode / Fresh-up mode Air to air cross flow total heat (sensible + latent heat) exchange Specially processed non-flammable paper Natural evaporating type 387x1,764x1,214 120 750 750 140 38.5 / 39 / 40 38.5 / 39 / 40 0°C~40°CDB, 80% RH or less -15°C~40°CDB, 80% RH or less 0°C~40°CDB, 80% RH or less 250 6.35 12.7 6.4 PT3/4 external thread 1~/50/220-240 15
387x1,764x832 102 500 500 160 37 / 37.5 / 38 37 / 37.5 / 38
200
Hz/V A
90
VKM100G 0.670 0.670 9.12 10.69 74 62
114 950 950 150 40 / 40.5 / 41 40 / 40.5 / 41
VKM100GM 0.670 0.670 9.12 10.69 74 62
125 950 950 110 39 / 39.5 / 40 39 / 39.5 / 40
FXMQ-MF
Outdoor air processing unit, ventilation and air processing
›› 100% fresh air intake possible ›› Ideal solution for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings ›› Operation range: -5°C to 43°C ›› Up to 225Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas
Ventilation & air processing Cooling capacity Nom. Heating capacity Nom. Power Input Cooling Nominal (50Hz) Heating Nominal HeightxWidthxDepth Dimensions Unit Weight Unit Air Flow Rate Cooling Heating External Static Pressure Standard Refrigerant Type Sound Power Cooling Nominal Nominal (220V) Sound Pressure Cooling Piping Liquid OD connections Gas OD Drain Power supply Phase / Frequency / Voltage
kW kW kW kW mm kg m3/min m3/min Pa dBA dBA mm mm
FXMQ125MF 14.0 8.9 0.359 0.359 470x744x1,100 86 18
FXMQ200MF 22.4 13.9 0.548 0.548
FXMQ250MF 28.0 17.4 0.638 0.638 470x1,380x1,100 123
28 225 R-410A -
185
42
35 205
47 9.52 19.1 PS1B 1~ / 50 / 220-240
15.9
Hz / V
91
22.2
EKEQMCB VRV® air handling applications
›› Integrated air conditioning and air handling solution from one supplier! ›› Connect any Air Handling Unit to any VRV®! –– Even geothermal-sourced VRV® WIII possible! EKEXV-kit
›› Efficiency of DX system both for cooling and for heating! ›› Unique application for Daikin VRV® III Heat Recovery with continuous heating during defrost!
EKEQMCB
gas pipe liquid pipe F1-F2 other communication
CONTROL BOXES
EKEQMCB
Control type Control options
Daikin control Room temperature control [via Remote Controller (accessory) or via External room temperature sensor (accessory)] Return air temperature control (via a supplied thermistor) Setpoint 16 ~ 32°C via Daikin Remote Controller (accessory) On / Off potential free input Fan Control potential free output (e.g. to stop AHU during defrost) Operation / Error output possible by accessory (KRP4A51)
Regulation range Inputs & Outputs
Daikin Remote Controller Dimensions
BRC1D52 BRC1E51A Height Width Depth
Weight Power supply
Expansion Valve Kits Allowed heat Cooling exchanger (evaporation capacity temp. 6°C) Heating (condensing temp. 46°C) Dimensions Weight Sound pressure level Operation range
Unit Unit Nom. Cooling Heating Operation range - Cooling on coil temperature Heating Refrigerant Type Piping Liquid connections Gas 1 2
Required for end-user control (order separatelly) 132 400 200 3.6 1~ / 230V / 50Hz
mm mm mm kg
Minimum Standard Maximum Minimum Standard Maximum HeightxWidthxDepth
Min./Max. Min./Max. Max. Min.
kW kW kW kW kW kW mm kg dBA °CDB °CWB °CDB °CDB
OD OD
mm mm
EKEXV50 5.0 5.6 6.2 5.6 6.3 7.0
EKEXV63 6.3 7.1 7.8 7.1 8.0 8.8
EKEXV80 7.9 9.0 9.9 8.9 10.0 11.1
6.35 6.35
45% relative humidity The temperature of the air entering the coil in heating mode can be reduced to -5°CDB. Contact your local dealer for more information
92
EKEXV100 EKEXV125 10.0 12.4 11.2 14.0 12.3 15.4 11.2 13.9 12.5 16.0 13.8 17.3 401x215x78 2.9 45 -5.0/46.0 -/351 102 R-410A 9.52 9.52
EKEXV140 15.5 16.0 17.6 17.4 18.0 19.8
EKEXV200 17.7 22.4 24.6 19.9 25.0 27.7
EKEXV250 24.7 28.0 30.8 27.8 31.5 34.7
PLUG and PLAY VRV® connection AHU
A ir H andling U nits for ›› VRV Indoor units and Air Handling Units on single VRV system ›› Monovalent cooling and heating for Air Handling Units ›› Air Handling Unit connection like standard VRV indoor unit ›› Factory engineered and mounted controls ›› Constant and comfortable supply air temperature control ›› Fast and easy installation ›› Standard DAIKIN warranty
With the new DAIKIN “PLUG and PLAY” VRV connection
In addition the Daikin Inverter technology for step-less
system VRV indoor units and Air Handling Units for
and efficient capacity control combined with the high-
fresh air treatment can be connected to the same re-
ly sophisticated factory engineered and mounted Air Han-
frigerant line, resulting in enhanced design flexibility
dling Unit controls are ensuring constant and comfort-
and increased energy efficiency. Both fresh air treat-
able supply air temperature.
ment and air conditioning can be achieved successfully
Last but not least not to forget about the business ad-
in a single direct-expansion system via DAIKIN VRV
vantages in which the DAIKIN “PLUG and PLAY” VRV con-
technology without the usual design problems of need-
nection will put you. The possibility of connecting the Air
ing VRV system for air conditioning and separate individ-
Handling Units together with the standard VRV indoor
ual heating and cooling systems just for the Air Handling
units in a monovalent heating and cooling VRV system
Units.
gives you the opportunity to completely get rid off the
The factory engineered and mounted controls package of
fossil fuel burning boilers, the chillers and the water piping
the Air Handling Units assures a fast and easy “PLUG and
from your projects and so reduce the total investment
PLAY” connection of the Air Handling Units just like a
cost significantly.
standard VRV indoor unit.
Altogether, the Daikin “PLUG and PLAY” VRV connection
This innovation brings a total monovalent direct-
system offers you the most efficient, easiest to install tech-
expansion solution to the heating, cooling and fresh
nology with lowest investment costs for the cooling and
air treatment demands of air conditioning applications.
heating needs of your air conditioning projects.
93
PLUG and PLAY VRV® connection AHU
Factory engineered and mounted controls For all Air Handling Units of the “PLUG and PLAY” VRV connection system a factory engineered and factory mounted controls package is included.
This package consists of: ›› Expansion valve kits EKEXV which are already mounted inside the unit so that only the refrigerant piping has to be connected. ›› Factory mounted control equipment for the AHU like temperature-, pressure sensors, dampers … ›› Control panel to control the whole AHU based on supply temperature including EKEQMCB boxes. This assures a fast and easy “PLUG and PLAY” connection of the Air Handling Units to a VRV system just like a standard VRV indoor unit. The possibility of operating the Air Handling Unit by using standard DAIKIN remote control greatly simplifies overall system control. Using a centralized remote control enables the user to choose from a wide range of control systems that integrate air conditioning and ventilation in a single control system structure.
Standardized preconfigured A ir H andling U nits The following preconfigured Air Handling Units are especially designed to meet the requirements which go along with the “PLUG and PLAY” VRV connection system as well as to assure maximum energy efficiency and comfort level for standard air conditioning applications.
Preconfigured Air Handling Unit
+ 94
Factory mounted controls
PLUG and PLAY VRV® connection AHU
S tandard spec . supply air only units for cooling only applications These units are single air stream (Supply fan only) with integrated mixing box (0-100% fresh air) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling mode only. Structure: Natural aluminum frame 40mm, Flat panel 25mm with foam insulation (40 ÷ 50 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm Components in Order of the direction of air flow: 1) Mixing box with dampers including 1 x louver, 1 x flexible connection and factor fitted actuators, 2) F5 bag filter with factory mounted differential pressure gauge and hinged door, 3) Section for factory mounted expansion valve kits EKEXV 4) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 5) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 6) Flexible connection, 7) 150 mm base frame
Air flow
m³/h
2.000
3.000
4.000
6.000
8.000
10.000
12.000
Width Height Length Weight Cooling capacity total Cooling capacity sensible External static pressure Max. Power input fan
mm mm mm kg kW kW Pa kW
950 810 3130 ~ 300 20,60 10,90 450 1,10
1000 940 3350 ~ 350 28,80 16,40 450 1,50
1150 960 3690 ~ 400 40,70 22,00 450 2,20
1350 1060 3691 ~ 470 58,70 32,90 450 3,00
1550 1060 4060 ~600 83,40 43,40 450 5,50
1550 1260 4290 ~700 100,30 55,20 450 5,50
1650 1310 4290 ~700 117,30 65,70 450 7,50
1 x EKEXV200 1 x EKEQMCB
1 x EKEXV250 1 x EKEQMCB
2 x EKEXV200 2 x EKEQMCB
2 x EKEXV250 2 x EKEQMCB
3 x EKEXV250 3 x EKEQMCB
4 x EKEXV200 4 x EKEQMCB
4 x EKEXV250 4 x EKEQMCB
1 x 184
1 x 257
2 x 182
2 x 262
3 x 248
4 x 224
4 x 262
Included VRV connection kit Capacity index
Conditions: Outside air: Summer 35°C/50% r.H.; Supply air: Summer 19°C 1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel 3) EKEXVs mounted inside Air Handling unit. EKEQMCB mounted inside control panel 4) Maximum Connection Ratio (CR) of the total VRV system: 110% 5) Sum of Capacity Indexes of EKEXVs must not exceed 30% when used in a system with other indoor units
95
PLUG and PLAY VRV® connection AHU
S tandard spec . supply and return air units for cooling / heating applications These units are double air stream (Supply and Return fan) with integrated mixing box (0-100% fresh air), heat recovery system (Pleat heat exchanger or rotary wheel) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling and heating mode. Structure: Natural aluminum frame 40mm, Flat panel 25mm with foam insulation (40 ÷ 50 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm Components in Order of the direction of air flow: Supply air stream: 1) Dampers section including 1 x louver, and factor fitted actuators, 2) F5 bag filter with factory mounted differential pressure gauge and hinged door, 3) Heat recovery system (Pleat heat exchanger or rotary wheel), 4) Mixing box with damper and factor fitted actuators, 5) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 6) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 7) Flexible connection, 8) 150 mm base frame Return air stream: 1) G4 flat filter with factory mounted differential pressure gauge and hinged door, 2) Return fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 3) Mixing box with damper and factor fitted actuators, 4) Heat recovery system (Pleat heat exchanger or rotary wheel), 5) Dampers section including 1 x louver, and factor fitted actuators
Air flow
m³/h
2.000
3.000
4.000
6.000
8.000
10.000
12.000
Width Height Length Weight Cooling capacity total Cooling capacity sensible Heating capacity total External static pressure Max. Power input supply fan Max. Power input return fan
mm mm mm kg kW kW kW Pa kW kW
950 1450 2960 ~ 550 20,6 10,9 11,25 450 1,10 1,10
1000 1710 3440 ~ 680 28,8 16,4 16,50 450 2,20 1,50
1150 1750 3190 ~ 700 40,7 22 21,30 450 2,20 2,20
1350 1950 3330 ~ 900 58,70 32,90 32,26 450 4,00 3,00
1550 1950 3730 ~ 1020 83,40 43,40 44,40 450 5,50 4,00
1650 2350 3700 ~ 1270 100,30 55,20 57,91 450 5,50 5,50
2000 2350 4020 ~ 1560 117,30 65,70 78,31 450 11,00 7,50
1 x EKEXV250 1 x EKEQMCB
1 x EKEXV250 1 x EKEQMCB
2 x EKEXV200 2 x EKEQMCB
2 x EKEXV250 2 x EKEQMCB
3 x EKEXV250 3 x EKEQMCB
4 x EKEXV200 4 x EKEQMCB
4 x EKEXV250 4 x EKEQMCB
1 x 184
1 x 257
2 x 182
2 x 262
3 x 248
4 x 224
4 x 262
Included VRV connection kit Capacity index
Conditions: Outside air: Summer 35°C/50% r.H., Winter -15°C/90% r.H.; Supply air: Summer 19°C, Winter 26°C 1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel 3) EKEXVs mounted inside Air Handling unit. EKEQMCB 4) Maximum Connection Ratio (CR) of the total VRV system: 110% 5) Sum of Capacity Indexes of EKEXVs must not exceed 30% when used in a system with other indoor units
96
PLUG and PLAY VRV® connection AHU
H igh spec . supply and return air units for cooling / heating applications These units are double air stream (Supply and Return fan) with integrated mixing box (0-100% fresh air), heat recovery system (Pleat heat exchanger or rotary wheel) and can operate, if connected to DAIKIN VRV outdoor unit, in cooling and heating mode. Structure: Natural aluminum frame 40mm, Step panel 42mm with mineral wool insulation (90 kg/m3), Skin material external Grey plastisol 0,7mm, Skin material internal galvanized 0,5mm Components in Order of the direction of air flow: Supply air stream: 1) Dampers section including 1 x louver, and factor fitted actuators, 2) Combined filter section G4 pre filter F7 bag filter with factory mounted differential pressure gauge and hinged door, 3) Heat recovery system (Pleat heat exchanger or rotary wheel), 4) Mixing box with damper and factor fitted actuators, 5) Direct expansion cooling coil with galvanized drain pan and droplet eliminator, 6) Supply fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 7) Empty section, 8) Sound attenuator 500 mm 9) F9 bag filter with factory mounted differential pressure gauge and hinged door 10) Flexible connection, 11) 150 mm base frame Return air stream: 1) F6 bag filter with factory mounted differential pressure gauge and hinged door, 2) Return fan (incl. hinged door, porthole, drive screen, mounted and wired light and on/off switch), 3) Mixing box with damper and factor fitted actuators, 4) Heat recovery system (Pleat heat exchanger or rotary wheel), 5) Dampers section including 1 x louver, and factor fitted actuators
Air flow
m³/h
2.000
3.000
4.000
6.000
8.000
10.000
12.000
Width Height Length Weight Cooling capacity Cooling capacity Heating capacity total External static pressure Max. Power input supply fan Max. Power input return fan
mm mm mm kg kW kW kW Pa kW kW
950 1450 4740 ~ 830 20,6 10,9 11,25 450 1,50 1,10
1000 1710 5170 ~ 990 28,8 16,4 16,50 450 2,20 1,50
1150 1750 4900 ~ 1070 40,7 22 21,30 450 3,00 2,20
1350 1950 5050 ~ 1301 58,70 32,90 32,26 450 4,00 3,00
1550 1950 5560 ~ 1520 83,40 43,40 44,40 450 5,50 4,00
1650 2350 5580 ~ 1835 100,30 55,0 57,91 450 7,50 5,50
1650 2350 5760 ~ 2230 117,30 65,70 78,31 450 11,00 7,50
1 x EKEXV250 1 x EKEQMCB
1 x EKEXV250 1 x EKEQMCB
2 x EKEXV200 2 x EKEQMCB
2 x EKEXV250 2 x EKEQMCB
3 x EKEXV250 3 x EKEQMCB
4 x EKEXV200 4 x EKEQMCB
4 x EKEXV250 4 x EKEQMCB
1 x 184
1 x 257
2 x 182
2 x 262
3 x 248
4 x 224
4 x 262
Included VRV connection kit Capacity index
Conditions: Outside air: Summer 35°C/50% r.H., Winter -15°C/90% r.H.; Supply air: Summer 19°C, Winter 26°C 1) Height including 150 mm Base frame 2) Width and Height without factory mounted control panel 3) EKEXVs mounted inside Air Handling unit. EKEQMCB mounted inside control panel 4) Maximum Connection Ratio (CR) of the total VRV system: 110% 5) Sum of Capacity Indexes of EKEXVs must not exceed 30% when used in a system with other indoor units
97
Air handling units
RANGE A wide standard range covers air flow rates from 1.100 m3/h up to 124.000 m3/h, with the possibility to choose the most appropriate transverse velocity, depending on the treatment required. In addition, with the same air flow, the flow section (width x height) can be adapted to the dimensional constraints of the installation. All sizes are modularly constructed to facilitate transport and easy assembly on site. With the absence of any welding points the Air Handling Units, on request, can be supplied completely dismantled to allow assembly directly on site. ›› P re-defined sizes Twenty-seven (27) fixed sizes optimized to reach the best compromise between competitiveness and manufacturing standardization. ›› “Infinitely” variable sizes designed to overcome installation constraints where space requirements of the section “width x height” must adapt to the available space. The system gives the possibility to tailor the unit sizes through increments/decrements of 5 cm. CONTROL Upon request all units can be provided with a regulation and control system that can manage the unit independently, or communicate with the external supervision system. Control panel power section, inverters, microprocessor, sensors to measure temperature, humidity and air quality, regulation valves, damper actuators, safety devices and control are just some of the components that can be installed upon request on the machine in order to provide an even more comprehensive product and faster installation.
98
Air handling units Technical choices All the units were developed by paying special attention to energy efficiency. Exchange surfaces, motor efficiency, filtration, isolation, friction reduction and pressure drop in the air flow inside the Air Handling Units are just some of the most important parameters considered in the development of the design. All of this provides a product ready to be easily inserted in the system and capable of contributing to overall energy savings.
Frame Structure with carrier chassis built with anodized aluminum (suitable for installation in a particularly aggressive atmosphere) or aluminum profiles of 40x40 or 60x60mm sections. There are solutions with thermal break (60x60mm section) or radial profile (suitable for applications in the food sector or in general, where a high level of hygiene is required). All profiles are double chamber type so that the fixing screws are totally concealed and there are no projections inside the Air Handling Units (in compliance with current accidentprevention regulations), and they are also fitted with a gasket to be inserted inside the profile, in a dovetail slot, to ensure maximum seal. The structure is completed with three way connecting, nylon loaded glass joints put on corners while the base, independent for each section, is in extruded aluminum with aluminum pressure diecast corners to facilitate lifting. Panels The closing panels are double sheets, box-folded and can be flat (25 and 46mm thickness) or step type (42 and 62mm thickness). The step panels permit a flat surface inside the unit, ensuring continuity between the panel and the profile. Insulation can be made of polyurethane foam (40 รท 50 kg/m3) or fibrous mineral wool, glued to the panel (90 kg/m3).
Flat panel
Polyurethane foam
Step panel
Aluminium profile with thermal break
Fan-Motor Assembly The Fan-Motor is made with a single structure comprising two aluminum profiles which help to absorb transmitted shock and a motor, mounted on a tensioning slide. The structure never touches on the bottom of the unit because through the aluminum profiles transfer the weight onto the structure of the AHU, ensuring the maximum vibration isolation. With this solution it can be sure that the AHU does not transmit vibrations to any flat surface on which is installed.
Base
Tensioning slide
Structure with two aluminium profiles
99
Corner
Air handling units Fittings The fasteners are stainless steel, self-tapping screws, located in nylon bosses and retained in the panel with an external cap. This system completely hides the screws in the panel and thanks to the self-fastening and self-centering screws, the tightness over time is ensured.
Fastener Nylon boss
Closure cap
Doors The doors for inspection and internal service can be provided with outward opening or inward opening for pressurized sections. There are solutions with hinges to allow left or right openings, or even the total removal of the door. Portholes The portholes are double-wall type made of polycarbonate and with sealing gaskets. The fastening system that provides the locking screws only enter the polycarbonate structure (and therefore not into the sandwich panel) and the continuous internal-external gasket, prevents the formation of condensation and ensures maximum sealing.
Fitting
Hinges (left or right openings, or even the total removal of the door)
Filters Particular attention is paid, during the configuration of the unit, to the position of the filters in the airflow, in order to maximize their effectiveness. All filters are mounted on commercial frames, provided with a seal to ensure effective filtration efficiency. In addition, all units are designed to allow the extraction of the filters from the dirt side in order to avoid possible contamination with the air circuit during maintenance.
Fastening system Internal-external gasket
Available Components Filter ›› Synthetic pleated filter ›› Flat filter aluminum mesh / stainless steel 304 ›› Rigid / Soft bag filter ›› High efficiency filter ›› Carbon absorption / deodorizing filter Exchangers ›› Water coils ›› Steam coils ›› Superheated water coils ›› Direct expansion coil ›› Electric coils
Humidifiers ›› Surface evaporation humidifier-constant loss water ›› Surface evaporation humidifier with re-circulating pump ›› Water spray humidifier constant loss water ›› Water spray humidifier with re-circulating pump ›› Steam humidifier with network distribution ›› Steam humidifier with local distributor ›› Atomized water spray humidifier
Fans ›› Forward curved fan ›› Backward curved fan ›› Plug fan (Also available with direct coupling) HEAT RECOVERY SYSTEMS ›› Heat wheel, sensible or enthalpy type ›› Cross-flow heat cube ›› Run-around coils OTHER SECTIONS ›› Attenuator section ›› Mixing box section with actuator or manual dampers ›› Empty section ›› Gas burner section ›› Factory mounted controls incl. Inverters
« O f fe r i n g a complete range: from standard model sizes to customised soluti o n s. » 100
ERQ
›› ›› ›› ›› ›› ›› ›› ›› ››
Heat-pump condensing unit
Highly efficient cooling and heating solution for air handling applications Saves on installation costs – no water piping, freezing protection, chillers or boilers needed to satisfy the fresh air heating and cooling loads Daikin Inverter technology for step-less and efficient capacity control ensuring constant and comfortable supply air temperature Wide capacity regulation range – down to 18% nominal capacity on size 250 Wide operation range – in heating down to -20°C and in cooling up to +43°C ambient temperature Flexible choice of regulations, from plug&play Daikin regulation, to sophisticated external control Wide range of options, such as low noise mode or externally-controlled power input limiting R410A direct expansion system for connection to external air heat exchangers
Expansion valve kit EKEXV
ERQ
Air handling unit
Liquid pipe
Gas pipe
Expansion valve control Thermistors
Daikin communication
Control box EKEQDCB EKEQFCB
Controller (Daikin or External)
102
ERQ
Heat-pump condensing unit
Heat pump ERQ100AV1
OUTDOOR UNITS Nominal Capacity * EER COP Combinable expansion valves Operation range - outdoor ERQ-AV1
Operation range on-coil indoor Sound power level Sound pressure level
ERQ125AW1
Defrost method Dimensions
Weight Refrigerant Piping dimensions
ERQ200~250AW1
Piping length Power supply Recommended fuses
Cooling Heating
kW kW
EKEXV # Cooling Heating Cooling Heating Cooling Heating Cooling Heating
°CDB °CWB °C °C dBA dBA dBA dBA
Height Width Depth
mm mm mm kg
R410A Liquid (OD) mm Gas (OD) mm Maximum m A
Expansion valve kits Nominal heat exchanger capacity* Heat exchanger inner volume Dimensions
EKEXV
Weight Sound pressure level Piping connections
minimum maximum minimum maximum Height Width Depth
In (OD) Out (OD)
kW kW l l mm mm mm kg dBA mm mm
ERQ125AV1
EKEQFCB
Regulation range
Inputs & Outputs
Daikin Remote Controller Dimensions
Weight Power supply
BRC1D52 / BRC1E51A Height mm Width mm Depth mm kg
Options/Accessories Electromechanical cool/heat selector (switch) Fixing box for cool/heat selector Drain pan kit with central drain outlet Daikin Remote Controller Adaptor for ext. monitoring/control External room temperature sensor
KRC19-26 KJB111A KWC26B160 KWC26B280 BRC1D52 / BRC1E51A KRP4A51 KRCS01-1
ERQ125AW1
14 15.5 16 18 3.99 3.42 4.15 3.94 63 ~ 140 80 ~ 140 -5 ~ +46 -20 ~ +15,5 +14 WB ~ +25 WB / +35 DB +10 DB ~ 27 DB 66 67 69 – – – 50 51 53 52 53 55 Reverse cycle, electronically controlled 1.345 900 320 120 4 9.52 9.52 9.52 15.9 15.9 19.1 55 1~ / 230V / 50Hz 32
ERQ200AW1
ERQ250AW1
14 16 3.98 4 63 ~ 140
22.4 28 25 31.5 4.29 3.77 4.5 4.09 100 ~ 250 125 ~ 250 -5 ~ +43 -20 ~ +15 +14 WB ~ +25 WB / +35 DB +10 DB ~ 27 DB 72 78 78 – – – 54 57 58 – – – Reverse cycle, electronically controlled 1.68 1.68 1.68 635 930 930 765 765 765 159 187 240 6.2 7.7 8.4 9.52 9.52 9.52 15.9 19.1 22.2 55 3N~ / 400V / 50Hz 16 25 25
EKEXV63
EKEXV80
EKEXV100
EKEXV125
EKEXV140
EKEXV200
EKEXV250
6.3 7.8
7.9 9.9
10 12.3
12.4 15.4 1.66 8.25 457 270 120 2.9 45 9.52 9.52
15.5 17.6
17.7 24.6
24.7 30.8
EKEQDCB
EKEQFCB
Daikin control Room temperature control [via Remote Controller (accessory) or via External room temperature sensor (accessory)]
Free (External) control 0~10V direct capacity control (5V = maintain capacity, >5V colder air wanted, <5V warmer air wanted)
Return air temperature control (via a supplied thermistor) Setpoint 16 ~ 32°C via Daikin Remote Controller (accessory)
On / Off potential free input Fan Control potential free output (e.g. to stop AHU during hot-start and defrost)
Fixed evaporation / condensation temperature control 0~10V input from external controller Fixed evaporation temperature setting to 5 ~ 12°C Fixed condensation temperature setting to 43 ~ 49°C On / Off potential free input Fan Control potential free output (e.g. to stop AHU during hot-start and defrost)
Operation / Error output possible by accessory (KRP4A51)
Defrost potential free output (e.g. to stop AHU during hot-start and defrost)
CONTROL BOXES Control type Control options
ERQ140AV1
11.2 12.5 3.99 4.56 63 ~ 125
Compressor operation potential free output Error indication potential free output Required for end-user control (order separatelly) Required for commissioning & service (order separatelly) 132 400 200 3.6 3.9 1~ / 230V / 50Hz
ERQ-AV1
ERQ125AW1
ERQ200.250AW1
• •
• • •
• •
EKEQDCB
EKEQFCB
• • •
•
•
103
CYQS/M/L-DK-F/C/R
Biddle standard air curtain for ERQ
Separate system for heating or cooling
ERQ
›› Air curtain for pair connection to ERQ heat pump ›› Amongst the first DX air curtains on the market ›› Payback of less then 1.5 years thanks to heat pump technology ›› Up to 85% climate separation efficiency thanks to rectifier technology, reducing down-flow turbulence to a minimum ›› Reduces heat losses, discomfort from cold draft, and requirement for internal heat sources Biddle standard air curtain (cy)
Small Biddle standard air curtain for connection to ERQ Power input Fan only Nom. Heating Nom. Delta T Inlet= room temperature Casing Colour Dimensions Height Unit F/C/R Width Unit F/C/R Depth Unit F/C/R Required ceiling void > Door height Max. Door width Max. Weight Unit Fan-Air flow rate Heating Sound pressure level Heating Refrigerant Type Piping connections Liquid (OD) / Gas Required accessories (should be ordered separately) Power supply Voltage
kW kW K mm mm mm mm m m kg m³/h dBA
V
Medium
CYQS150DK80F*BN / *SN CYQS200DK100F*BN / *SN CYQS250DK140F*BN / *SN CYQM100DK80F*BN / *SN CYQM150DK80F*BN / *SN CYQM200DK100F*BN / *SN CYQM250DK140F*BN / *SN 0.35 0.46 0.58 0.37 0.56 0.75 0.94 0.35 0.46 0.58 0.37 0.56 0.75 0.94 15 16 17 14 13 15 BN: RAL9010 / SN: RAL9006 BN: RAL9010 / SN: RAL9006 270 / 270 / 270 270 / 270 / 270 1,500 / 1,500 / 1,548 2,000 / 2,000 / 2,048 2,500 / 2,500 / 2,548 1,000 / 1,000 / 1,048 1,500 / 1,500 / 1,548 2,000 / 2,000 / 2,048 2,500 / 2,500 / 2,548 290 / 821 / 561 290 / 821 / 561 420 420 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.3 (1) / 2.15 (2) / 2.0 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 2.5 (1) / 2.4 (2) / 2.3 (3) 1.5 2.0 2.5 1.0 1.5 2.0 2.5 66 83 107 57 73 94 108 1,746 2,328 2,910 1,605 2,408 3,210 4,013 49 50 51 50 51 53 54 R-410A R-410A 9.52 / 16.0 9.52 / 19.0 9.52 / 16.0 9.52 / 19.0 Daikin wired remote control (BRC1E51A or BRC1D52) Daikin wired remote control (BRC1E51A or BRC1D52) 230 230
Large Biddle standard air curtain for connection to ERQ Power input Fan only Nom. Heating Nom. Delta T Inlet= room temperature Casing Colour Dimensions Height Unit F/C/R Width Unit F/C/R Depth Unit F/C/R Required ceiling void > Door height Max. Door width Max. Weight Unit Fan-Air flow rate Heating Sound pressure level Heating Refrigerant Type Piping connections Liquid (OD) / Gas Required accessories (should be ordered separately) Power supply Voltage
kW kW K mm mm mm mm m m kg m³/h dBA
CYQL100DK125F*BN / *SN 0.75 0.75
CYQL150DK200F*BN / *SN 1.13 1.13 15
1,000 / 1,000 / 1,048
3.0 (1) / 2.75 (2) / 2.5 (3) 1.0 76 3,100 53 9.52 / 16.0
V
F: Freehanging model, C: Cassette model, R: Recessed model (1) Favourable condition | (2) Normal condition | (3) Unfavourable condition
104
CYQL200DK250F*BN / *SN CYQL250DK250F*BN / *SN 1.50 1.88 1.50 1.88 14 12 BN: RAL9010 / SN: RAL9006 370 / 370 / 370 1,500 / 1,500 / 1,548 2,000 / 2,000 / 2,048 2,500 / 2,500 / 2,548 745 / 745 / 745 520 3.0 (1) / 2.75 (2) / 2.5 (3) 3.0 (1) / 2.75 (2) / 2.5 (3) 3.0 (1) / 2.75 (2) / 2.5 (3) 1.5 2.0 2.5 100 126 157 4,650 6,200 7,750 54 56 57 R-410A 9.52 / 16.0 9.52 / 22.0 Daikin wired remote control (BRC1E51A or BRC1D52) 230
CYVS/M/L/XL-DK-F/C/R
Biddle standard air curtain for VRV
VRV® NETWORK SOLUTION
›› Air curtain for pair connection to VRV systems ›› Amongst the first DX air curtains on the market ›› Payback of less then 1.5 years thanks to heat pump technology ›› Up to 85% climate separation efficiency thanks to rectifier technology, reducing down-flow turbulence to a minimum ›› Reduces heat losses, discomfort from cold draft, and requirement for internal heat sources Biddle comfort air curtain (ca)
Small Indoor units Heating capacity
Speed 3 Speed 4 Power input Fan only Nom. Heating Nom. Delta T Speed 3 Speed 4 Casing Colour Dimensions Height Unit F/C/R Width Unit F/C/R Depth Unit F/C/R Required ceiling void > Door height Favorable/Normal/ Unfavorable conditions Door width Max. Weight Unit Unit F/C/R Fan-Air flow rate Heating Speed 3 Heating Speed 4 Sound pressure level Heating Speed 3 Heating Speed 4 Refrigerant Type Piping connections Liquid (OD) / Gas Required accessories (should be ordered separately) Power supply Voltage
kW kW kW kW K K mm mm mm mm m m kg m³/h m³/h dBA dBA
Medium
CYVS100DK80*BC/*SC CYVS150DK80*BC/*SC CYVS200DK100*BC/*SC CYVS250DK140*BC/*SC CYVM100DK80*BC/*SC CYVM150DK80*BC/*SC CYVM200DK100*BC/*SC CYVM250DK140*BC/*SC 4.8 6.1 7.9 10.9 6.1 7.5 9.7 13.4 6.0 7.5 9.7 13.3 7.7 9.4 12.1 16.8 0.20 0.30 0.40 0.50 0.28 0.42 0.56 0.70 0.20 0.30 0.40 0.50 0.28 0.42 0.56 0.70 22 19 18 20 20 17 16 18 20 17 16 18 15 14 16 BC:RAL9010 / SC:RAL 9006 270 / 270 / 270 1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548 1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548 590 / 821 / 561 420 2.4 / 2.2/ 1.0 61 / 59 / 61 670 880 36 42
mm
1.5 73 / 83 / 88 1,000 1,310 38 44 9.52 / 16.0
V
2.8 / 2.5 / 2.2
2.0 2.5 1.0 1.5 89 / 102 / 108 101 / 129 / 137 66 / 68 / 66 79 / 88 / 93 1,340 1,670 750 / 890 1,120 / 1,330 1,750 2,190 890 / 1,230 1,330 / 1,840 39 40 32 / 37 34 / 39 45 46 37 / 45 39 / 47 R-410A 9.52 / 19.0 9.52 / 16.0 Daikin wired remote control (BRC1E51A or BRC1D52) 230
Large Indoor units Heating capacity
Speed 3 Speed 4 Power input Fan only Nom. Heating Nom. Delta T Speed 3 Speed 4 Casing Colour Dimensions Height Unit F/C/R Width Unit F/C/R Depth Unit F/C/R Required ceiling void > Door height Favorable/Normal/ Unfavorable conditions Door width Max. Weight Unit Unit F/C/R Fan-Air flow rate Heating Speed 3 Heating Speed 4 Sound pressure level Heating Speed 3 Heating Speed 4 Refrigerant Type Piping connections Liquid (OD) / Gas Required accessories (should be ordered separately) Power supply Phase / Frequency / Voltage
kW kW kW kW K K mm mm mm mm m
9.52 / 19.0
XLarge
CYVL100DK125*BC/*SC CYVL150DK200*BC/*SC CYVL200DK250*BC/*SC CYVL250DK250*BC/*SC CYVXL100DK125*BC/*SC CYVXL150DK200*BC/*SC CYVXL200DK250*BC/*SC CYVXL250DK250*BC/*SC 10.6 15.9 20.3 22.1 12.3 18.6 23.6 25.4 12.5 18.8 24.0 25.8 14.7 22.0 27.8 29.6 0.75 1.13 1.50 1.88 1.40 2.10 2.80 3.50 0.75 1.13 1.50 1.88 1.40 2.10 2.80 3.50 18 15 17 16 14 17 16 14 15 12 BC:RAL9010 / SC:RAL 9006 370 / 370 / 370 1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548 1,123 / 1,000 / 1,048 1,623 / 1,500 / 1,548 2,123 / 2,000 / 2,048 2,623 / 2,500 / 2,548 774 / 1,105 / 745 520 3.3 / 3.0 / 2.5
m kg m³/h m³/h dBA dBA
1.0 83 / 81 / 83 1,330 / 1,730 1,730 / 2,210 40 / 46 45 / 51
mm
9.52 / 16.0
Hz / V
2.0 2.5 97 / 111 / 117 119 / 136 / 144 1,490 / 1,770 1,870 / 2,215 1,770 / 2,450 2,220 / 3,060 35 / 40 36 / 41 40 / 48 4 / 49
3.8 / 3.5 / 3.0
1.5 2.0 2.5 1.0 1.5 2.0 2.5 108 / 118 / 141 137 / 151 / 155 166 / 190 / 196 69 / 84 / 86 102 / 123 / 146 130 / 160 / 164 162 / 198 / 204 2,000 / 2,600 2,670 / 3,470 3,330 / 4,340 1,610 / 2,160 2,420 / 3,250 3,230 / 4,330 4,030 / 5,410 2,600 / 3,320 3,470 / 4,430 4,340 / 5,530 2,160 / 2,800 3,250 / 4,190 4,330 / 5,590 5,410 / 6,990 42 / 48 43 / 49 44 / 50 46 / 52 48 / 53 49 / 55 50 / 56 47 / 53 48 / 54 49 / 55 51 / 56 53 / 58 54 / 59 55 / 60 R-410A 9.52 / 19.0 9.52 / 22.0 9.52 / 16.0 9.52 / 19.0 9.52 / 22.0 Daikin wired remote control (BRC1E51A or BRC1D52) 230
1 in case of connection to a VRV® heat recovery outdoor unit F: Freehanging model, C: Cassette model, R: Recessed model
*Note: grey cells contain preliminary data
105
Contact your local dealer for availability
BRC1E52A BRC1E52B
User friendly remote control with contemporary design
What’s new? Energy saving functions
A series of energy saving functions that can be individually selected ›› ›› ›› ›› ›› ››
Temperature range limit Setback function Presence & floor sensor connection (available on new round flow cassette) kWh indication Set temperature auto reset Off timer
Temperature range limit avoids excessive heating or cooling Save energy by constraining the lower temperature limit in cooling and upper temperature limit in heating mode. note : Also available in auto cooling/heating change over mode.
kWh indication keeps
track of your consumption The kWh indication shows an indicative electricity consumption of the last day/month/year.
Other functions NEW ›› IMPROVED ››
›› ›› ›› ›› ›› ››
Up to 3 independent schedules can be set, so the user can easily change the schedule himself throughout the year (e.g. Summer, winter, mid-season) Possibility to individually restrict menu functions Easy to use: all main functions directly accessible Easy setup: clear graphical user interface for advanced menu settings Real time clock with auto update to daylight saving time Supports multiple languages (English, German, Dutch, Spanish, Italian, Portuguese, French, Greek, Russian, Turkish, Polish (NEW)) From the 2nd half of 2012, further language will become available in the version BRC1E52B (Albanian, Bulgarian, Croatian, Czech, Hungarian, Romanian, Serbian, Slovakian, Slovenian) Built-in backup power: when a power failure occurs all settings remain stored up to 48 hours 107
Graphical display of indicative electricity consumption
Individual control systems
BRC944B2
BRC944B2
ARC466A1
BRC4*/BRC7*
BRC2C51
BRC944B2*/BRC1D52 Wired remote control
››
›› ›› ›› ›› ››
Schedule timer:
• Five day actions can be set as follows: -- set point: unit is switched ON and normal operation is maintained -- OFF: unit is switched OFF1 -- limits: unit is switched ON and min./max. control (cf. limit operation for more details) Home leave (frost protection): during absence, the indoor temperature can be maintained at a certain level. This function can also switch the unit ON/OFF User friendly HRV function, thanks to the introduction of a button for ventilation mode and fan speed Constantly monitoring of the system for malfunctions in a total of 80 components Immediate display of fault location and condition Reduction of maintenance time and costs
Display Operating mode1 Heat Recovery Ventilation (HRV) in operation Cool / heat changeover control Centralised control indication Group control indication Set temperature1 Air flow direction1 Programmed time Inspection test / operation Fan speed1 Clean air filter Defrost / hot start Malfunction
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
1
Only functions marked with ‘1’ are available on BRC944B2
ARC4*/BRC4*/BRC7*
BRC2C51
Operation buttons: ON / OFF, timer mode start / stop, timer mode on / off, programme time, temperature setting, air flow direction, operating mode, fan speed control, filter sign reset , inspection / test indication
Simple, compact and easy to operate unit, suitable for use in hotel bedrooms
Infrared remote control
Display: Operating mode, battery change, set temperature, air flow direction , programmed time, fan speed, inspection / test operation For all features of the remote control, refer to the operation manual
Simplified remote control
Operation buttons: ON/OFF, operating mode selection, fan speed control, temperature setting Display: Cool/heat changeover control, Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode, centralised control indication, fan speed, defrost/hot start, malfunction adjustment, operating mode selection, fan speed control, filter sign reset, inspection test/operation
108
Centralised control systems
DCS302C51
DCS301B51
Basic control
DST301B51
Centralised control of the VRV system can be achieved via 3 user friendly compact controls: centralised remote control, unified on/off control and schedule timer. These controls may be used independently or in combination where 1 group = several (up to 16) indoor units in combination and 1 zone = several groups in combination. A centralised remote control is ideal for use in tenanted commercial buildings subject to random occupation, enabling indoor units to be classified in groups per tenant (zoning). The schedule timer programmes the schedule and operation conditions for each tenant and the control can easily be reset according to varying requirements.
DCS302C51
DCS301B51
DST301B51
Providing individual control of 64 groups (zones) of indoor units.
Providing simultaneous and individual control of 16 groups of indoor units.
Enabling 64 groups to be programmed.
• a maximum of 64 groups (128 indoor units, max. 10 outdoor units) can be controlled • a maximum of 128 groups (128 indoor units, max. 10 outdoor units) can be controlled via 2 centralised remote controls in separate locations • zone control • group control • malfunction code display • maximum wiring length of 1,000m (total: 2,000m) • air flow direction and air flow rate of HRV can be controlled • expanded timer function
• a maximum of 16 groups (128 indoor units) can be controlled • 2 remote controls in separate locations can be used • operating status indication (normal operation, alarm) • centralised control indication • maximum wiring length of 1,000m (total: 2,000m)
• a maximum of 128 indoor units can be controlled • 8 types of weekly schedule (when combined with DCS302C51) • a maximum of 48 hours back up power supply • a maximum wiring length of 1,000m (total: 2,000m)
Centralised remote control
Unified ON/OFF control
109
Schedule timer
DCS601C51 Intelligent Touch Controller
Centralised control systems third party controller (domotics, BMS, etc.) (option DCS007A51)
Detailed & easy monitoring and operation of VRV systems (max. 2 X 64 groups/indoor units).
Ethernet
Fire alarm Forced OFF contact input
PCMCIA flash memory
DIII-NET
CSV output of PPD (option) result (option DCS002C51)
Indoor units
HRV
Pi-port Onboard Ethernet port
DIO unit (DEC102A51) Links to the wattmeter when using the PPD Controls drain pump lighting etc. (DEC102A51)
(option) function
Malfunction
DI unit (DEC101A51) Remote monitoring/control via internet, e-mail PPD data is available on the internet (option DCS004A51)
Monitoring of room enter/ exit sign (DEC101A51)
DIII-NET Allows monitoring/control of up to 64 units (groups) of A/Cs and equipment RS-232C
DIII-NET PLUS adapter (DCS601A52) Indoor units
HRV
LANGUAGES
CONTROL
COST PERFORMANCE
›› ›› ›› ›› ›› ›› ››
››
›› ›› ›› ›› ››
English French German Italian Spanish Dutch Portuguese
SYSTEM LAYOUT ›› ›› ›› ››
Up to 2 x 64 indoor units can be controlled Onboard Ethernet port (web browser + e-mail) Digital i/o contacts (option) Touch panel (full colour LCD via icon display)
MANAGEMENT ››
›› ›› ›› ››
Web application & internet compatibility (option DCS004A51) - Monitoring & control according to user - Remote monitoring & control of more than one building - Remote monitoring & control of more than one building via internet
Power Proportional Distribution: PPD (option DCS002C51) PPD data is available on the internet Easy management of electricity consumption Enhanced history function
›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Individual control (set point, start/stop, fan speed) (max. 2 x 64 groups/indoor units) Set back shedule Enhanced scheduling function (8 schedules, 17 patterns) Flexible grouping in zones Yearly schedule Fire emergency stop control Interlocking control Increased HRV monitoring and control function Automatic cooling / heating change-over Heating optimization Temperature limit Password security: 3 levels (general, administration & service) Quick selection and full control Simple navigation
MONITORING ›› ›› ›› ›› ›› ››
Visualisation via Graphical User Interface (GUI) Icon colour display change function Indoor units operation mode Error messages via e-mail & mobile phone (option) Indication filter replacement Multi PC
110
Free cooling function Labour saving Easy installation Compact design: limited installation space Overall energy saving
OPEN INTERFACE ›› ›› ››
Communication to any third party controller (domotics, BMS, etc.) is possible via open interface HTTP communication protocol Available as option DCS007A51
CONNECTABLE TO ›› ›› ›› ››
VRV HRV Sky Air (via interface adapter) Split (via interface adapter)
DAM602B51/52 Intelligent Manager
Centralised control systems
[iPU]
Full control and management of VRV systems (Maximum 200 groups)
~
Intranet/Internet Web Access
Web Access Malfunction report by E-Mail
Ai unit (DAM101A51)
DAM602B51/52
DIII-NET DIII-NET DIII-NET
DIII-NET
ETHERNET
Windows Vista Compatible
Fire alarm
~
Sub PC
Dio unit (DDEC102A51)
DMS502A51 (monitoring only)
Local monitoring & control
Power supply facility · Elevator · Pump · Lighting,...
Electricity Measurement
VRV System
Daikin Central Air Conditioning System HRV
LANGUAGES
MANAGEMENT
MONITORING
›› ›› ›› ›› ›› ›› ››
›› ››
››
English French German Italian Spanish Dutch Portuguese
SYSTEM LAYOUT ›› ›› ››
›› ››
Up to 1,024 indoor units can be controlled (by 4 iPUs) Ethernet TCPIP / 10 base / T communication Integrated digital contacts on the Intelligent Processing Unit (iPU) - 20 general input ports - 2 digital outputs Stand alone operation of the iPU for minimum 48 hours Compatible with UPS shutdown software
›› ›› ›› ›› ›› ›› ››
Web access (option) (option DAM004A51) Power Proportional Distribution (option DAM002A51) Operational history management (start/ stop, malfunction, operation hours) Generation of reports (graphics & tables) (daily, weekly, monthly) Peak load shedding Advanced tenant management Sliding temperature Eco mode (option DAM003A51) Pre-cooling and -heating function
CONTROL ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
Individual control (setpoint, start/stop, fan speed) (max. 1,024 indoor units) Group control (100 groups) Schedule control (128 programs) Fire emergency stop control (32 programs) Interlocking control Setpoint limitation Automatic cooling/heating change-over Power failure/release control Temperature limit (automatic start) Timer extension
111
›› ›› ›› ›› ›› ›› ››
Visualisation via a Graphical User Interface (GUI) featuring free layout Operation mode of indoor units Fault indication Indication filter replacement Setpoint indication Operation time monitoring Multi PC On-line help
COST PERFORMANCE ›› ›› ›› ››
Labour saving Easy installation Compact design: limited installation space Overall energy saving
CONNECTABLE TO ›› ›› ›› ››
VRV HRV Sky Air (via interface adapter) Split (via interface adapter)
Advanced individual unit control & interfaces
RTD-10 / -NET / -HO Universal control adaptors
Monitor and control one group of VRV or Sky Air indoor units via a third party control or BMS system External interface gateways RTD-10 Advanced integration into BMS system of VRV, Sky Air, VAM and VKM through either: ›› Modbus ›› Voltage (0-10V) ›› Resistance
RTD-NET Modbus interface for monitoring and control of VRV, Sky Air, VAM and VKM
RTD-HO Intelligent hotel room controller
Overview of functions MAIN FUNCTIONS Dimensions HxWxD Key card + window contact Set back function Prohibit or restrict remote control functions (setpoint limitation, ...) Modbus (RS485) 0 - 10 V control Resistance control IT application (automatic back-up and rotation between units Heating interlock Output signal (on/defrost, error)
RTD-10 mm
RTD-NET 100 x100 x 22
RTD-HO
RTD-10 M,V,R M,V,R M,V,R M,V,R M,V,R M,V,R M,V,R
RTD-NET M M M M M M M
RTD-HO M* M* M* M* M*
RTD-10 RTD-NET MONITORING FUNCTIONS M, C M On/Off M M Set point M M Mode M M fan M M Louver M M RC temperature M M RC mode M M nbr units M, C M Fault M M Fault code M M Return air temperature (Average /Min/Max) M M Filter alarm M M Termo on M, C** M Defrost M M Coil In/Out temperature M: Modbus, V: Voltage, R: Resistance, C: Potential-free Contact, *: only when the room is occupied, **: Either On/Off or Defrost can be indicated, not both
RTD-HO M, C M M M M M M M M, C M M M M M M
CONTROL FUNCTIONS On/Off Set point Mode fan Louver HRV Damper control Prohibit/Restrict functions
112
M*
Advanced individual unit Daikin systems controlcontrol & interfaces
DTA113B51 DS-Net Adaptor
Basic solution for control of Sky Air and VRV
DS-NET adapter
GSM modem (field supply) RS232C
BRC1D52
Up to 4 units / 1 adapter
Mobile phone (field supply)
›› ›› ››
monitoring function control function error notification
FUNCTIONS 1. Monitoring Functions
You can monitor your air conditioning units by simply sending a text message with your mobile phone with the word “Report”: ›› Start/stop ›› Operation mode (fan/cool/heat) ›› Temperature setting ›› Error code
3. Error Notification
When an error occurs, a text message will be sent automatically to your mobile phone (error notification).
4. Stand alone operation
›› ››
2 . Control Functions
You can control your air conditioning units by simply sending a text message via your mobile phone: ›› Start/stop ›› Operation mode (fan/cool/heat) ›› Temperature setting
Daikin recommends the use of a Wavecom Fastrack modem
113
Rotation function Backup operation function.
Advanced individual unit control & interfaces
KKRP01A Online Controller
Always in control, no matter where you are
Daikin provides a new control solution to monitor and control the main functions of the residential indoor units. The system is working in an end-user friendly way and can be used from any location via your smartphone, laptop, PC, tablet, app
or wired remote controller.
1
Wired controller
2 PC
3 Smartphone
Residential use:
Light commercial use:
Optimal home comfort / holiday home surveillance ›› Create a comfortable home climate at any time and at any place ›› Remote detection of failures
Flexible office solution ›› Dynamic group control in open space ›› Fault manager / event logger ›› Easily create a yearly schedule (iPlanner) ›› Back-up configuration of air conditioning
Available software packages Residential*
Light commercial **
Extended light commercial **
Possibility to control multiple indoor units via internet (over 9 KKRP01s)
Filtering data OK / ERR
Possibility to control indoor unit via internet Possibility to control multiple indoor units via internet (up to 9 KKRP01s)
Advanced filtering (OK / ANY ERR / COMM ERR / AC / ERR)
Sorting by all columns from data-grid
History of alerts
History of temperatures
History of commands
Graphic single controller with weather forecast
Text group controller
Weekly planner
I-planner (yearly schedule) Receive via e-mail an alert report
Autonomous periodical connectivity check
Exceeded room temperature limits e-mail report
* standard programmed on KKRP01A ** Additional software to be purchased online
114
Advanced individual unit control & interfaces
KKRP01A Online controller
Possible indoor units: Standard ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ›› ››
FTXR28-50E FTXG25-50J FTXG25-35E CTXG50J CTXG50E FTXS20-71G FTK/XS20-50D FTXS50-71F FTXS20-50J FTX50-71GV FTYN50-60F FVXS25-50F FVXG25-50K FLK/XS25-60C/E ATXS20-50E ATXS20-50G ATXG25-35E
App It will be possible to control your air conditioning via an app. This app will become available for download.
Specifications Online controller KKRP01A Communication interfaces Ethernet LAN 10/100 Mbit/s MODBUS
for connection intro LAN network for connection of accessories
serial S21 cable 1,3m
for connection with A/C indoor unit
Power supply
directly from IU - 5 V DC for Online Controller, 12 V DC for accessories
Power consumption
120 mA, 0.6 W
IP code Others
IP10 / IP44 - inside A/C unit
Mounting Weight
inside of A/C IU or intro External Mounteing Kit 50g
Dimensions (W X h X d)
64 X67 X 17 mm (without cable)
Options MATERIAL NAME
DESCRIPTION
EXPLANATION
KKRPM01A
External mounting kit
To install online controller outside the indoor unit or to extend the length of the cable between indoor unit and KKRP01A. It can easily be mounted on the wall of hidden in false ceilings.
KKRPW01A
Wifi Cable Pack
To enable wireless internet connection. Wifi module to be purchased locally.
KBRCS01A
Easy wall controller
KBRC01A
Touch LCD wall controller
Wired controller to be installed on the wall. Designed to easily control one indoor unit or a group of indoor units.
115
KLIC-DI / -DD KNX Protocol
Standard protocol interfaces
Integration of Split, Sky Air and VRV
in HA/BMS systems
Concept
Connect split indoor units to KNX interface for Home Automation system
light house
Interface Daikin protocol/ KNX
Domotica Controller
Concept
Connect Sky Air / VRV indoor units to KNX interface for BMS integration
shutter control tv
light shop
Interface Daikin protocol/ KNX
Domotica Controller
shutter control
tv
KNX interface line-up The integration of Daikin indoor units through the KNX interface allows monitoring and control of several devices, such as lights and shutters, from one central controller. One particularly important feature is the ability to programme a ‘scenario’ - such as “Home leave” - in which the end-user selects a range of commands to be executed simultaneously once the scenario is selected. For instance in “Home leave” , the air conditioner is off, the lights are turned off, the shutters are closed and the alarm is on.
KNX interface for KLIC-DD Size 90x60x35mm Split
KLIC-DI Size 45x45x15mm Sky Air
VRV
BASIC CONTROL On/Off Mode Temperature Fan speed levels Swing
Auto, heat, dry, fan, cool
3 or 5 + auto Stop or movement
Advanced functionalities Error management Scenes Auto switch off Temperature limitation Initial configuration Master and slave configuration
Standard protocol interfaces Modbus interface for monitoring and control of up to 16 VRV, Sky Air, VAM or VKM indoor units
Auto, heat, dry, fan, cool
Auto, heat, dry, fan, cool
2 or 3 Stop or movement
2 or 3 Swing or fixed positions (5)
Communication errors, Daikin unit errors
RTD-NET Modbus Protocol
To indoor unit power supply
To indoor unit via P1/P2
116
To BMS system (modbus)
DMS502A51 BACnet Protocol
Standard protocol interfaces
BACnet Interface Integrated control system for seamless connection between VRV and BMS systems
›› ›› ›› ›› ›› ››
PPDdata is available on BMS system Interface for BMS system Communication via BACnet protocol (connection via Ethernet) 256 units connectable per BACnet gateway Unlimited sitesize Easy and fast installation
DIII- NET
DAM602B51/52
Local Control
BACNET / ETHERNET
VRV Outdoor unit HRV
DAIKIN A/C INFRASTRUCTURE Remote Control
Fire alarm
BUILDING CONTROL NETWORK
Pump
Security
Power supply facility
Lighting
Elevator
DMS504B51 LonTalk Protocol
Standard protocol interfaces
LonWorks Interface Open network integration of VRV monitoring and
LON BMS
›› ›› ›› ››
control functions into LonWorks networks
Interface for Lon connection to LonWorks networks Communication via Lon protocol (twisted pair wire) 64 units connectable per DMS-IF Unlimited sitesize Quick and easy installation
dms504b51
LonTalk
DIII- NET
adapter ETHERNET (TCP/IP)
››
Local Control VRV Outdoor unit HRV
LonTalk adapter Remote Control LonPoint
LonPoint
BUILDING CONTROL NETWORK
DAIKIN A/C INFRASTRUCTURE
Security
117
Fire alarm System
K.RSS
Wireless room temperature sensor
Flexible and easy installation Accurate temperature measurement thanks to flexible placement of the sensor ›› No need for wiring ›› No need to drill holes ›› Ideal for refurbishment ››
Connection diagram Daikin indoor unit PCB (FXSQ-P example) Air sensor – X16A, X19
Power supply – X35, X13 RF sender
Rf Receiver
Specifications
Wireless room temperature sensor kit (K.RSS) WIRELESS ROOM TEMPERATURE RECEIVER WIRELESS ROOM TEMPERATURE SENSOR
Dimensions
mm
Weight
g
Power supply Battery life Battery type Operation range
››
+/- 3 years 10
°C
0~50
MHz
868.3
Type Frequency
3 Volt Lithium battery
m
RF
Room temperature is sent to the indoor unit every 90 seconds or if the temperature difference is 0.2°C or larger.
KRCS01-1B KRCS01-4B ››
N/A
N/A N/A
Maximum range
Communication
16VDC, max. 20 mA
Wired room temperature sensor
Accurate temperature measurement, thanks to flexible placement of the sensor
Specifications Dimensions (HxW)
mm
Weight
g
60 x 50 300
Length of branch wiring
m
12
118
Other integration devices
Adapter PCB’s – Simple solutions for unique requirements Daikin’s adapter PCB’s provide simple solutions for unique requirements. They are a low cost option to satisfy simple control requirements and can be used on single or multiple units.
•
Output signal wiring adaptors Provide potential-free output contacts indicating compressor operation (or error signal) and indoor unit fan operation Versions with 4 outputs additionally provide 230V output contacts for control of 3rd party auxiliary booster heaters and humidifiers Connects to the indoor units PCB, for installation in the indoor unit
• • • • • •
Simultaneous On/Off and set-point control of entire DIII-Net line (up to 128 indoor units / 64 groups) Set-point control by resistance signal (0-140Ω) Possibility to restrict On/Off control by local remote controllers Sum operation and error potential-free output contacts Connects to F1/F2 line and indoor unit PCB, for installation in the indoor unit Not combinable with other Daikin centralized control solutions
Wiring adaptor for electrical appendices
• • • • • •
On/Off and set-point control of up to 16 VRV® or SkyAir® indoor units (1 remote controller group) Set-point control by resistance signal (0-140Ω) Possibility to restrict On/Off control by local remote controllers Operation and error potential-free output contacts Connects to P1/P2 line and indoor unit PCB, for installation in the indoor unit Must be installed together with a local remote controller (BRC*)
DTA104A*
•
E xternal activation of demand limitation (limitation of system’s power input to <10%, 40%, 60%, 70%, or 80%) External activation of low noise mode (limitation of outdoor unit’s sound level) Simultaneous operation mode switching of multiple heat pump systems
(E)KRP1B* (E)KRP1C* Adapter for wiring
KRP2A* Wiring adaptor for electrical appendices
KRP4A*
Outdoor Unit External Control Adapter
Concept and benefits
• • •
• •
›› ››
Low cost option to satisfy simple control requirements Deployed on single or multiple units
119
Options & accessories -
outdoor
Total Solution VRV
Multi-module connection kit (obligatory) Connects multiple modules into a single refrigerant system Extended level difference kit Allows outdoor unit to be more than 50m above indoor units
VRV III Heat Recovery
REYAQ 10~16
REYQ 8~16
REMQ 8~12
REMHQ 12
REMQ 14~16
2-module systems
3-module systems
-
-
-
-
-
BHFQ23P907
BHFQ23P1357
-
Special order unit
Special order unit
Special order unit
Special order unit
Special order unit
Special order unit
KWC25C450
KWC25C450
KWC26B280
KWC26B450
KWC26B450
1 kit per module
1 kit per module
-
-
-
-
-
-
-
Central drain pan kit Installs onto the underside of the outdoor unit and collects drain water from all bottom plate outlets into a single outlet. In cold areas should be heated by a field-supplied heater to prevent drain water from freezing in the drain pan. Bottom plate heater kit Optional electrical heater for the VRV casing’s bottom plate to guarantee trouble-free operation even in extremely cold and humid climates External control adaptor for outdoor unit DTA104A53/61/62 For installation into an indoor unit: exact adaptor type depends on type of indoor unit. See Options & Accessories of indoor units
Allows to activate Low Noise Operation and three levels of Demand Limiting via external dry contacts. Connects to the F1/F2 communication line and requires power supply from an indoor unit*, BSVQ box, or VRV-WIII outdoor unit. BHGP26A1 Digital pressure gauge kit – displays current condensing and evaporating pressures in the system as standard, or expansion valve positions and temperature sensor data in a special service mode. Connect to the outdoor unit PCB, for installation in the outdoor unit.
-
✓
✓
✓
✓
1 kit per system
1 kit per system
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KRC19-26 Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the A-B-C terminals of the outdoor unit / BS-box. KJB111A Installation box for remote cool/heat selector KRC19-26
VRV III Heat Pump with for stylish indoor units
Multi-module connection kit (obligatory) Connects multiple modules into a single refrigerant system Extended level difference kit Allows outdoor unit to be more than 50m above indoor units
VRV III-S Mini VRV
VRV III-Q Heat Recovery Replacement VRV
RXYRQ 8~12
RXYRQ 14~18
RXYSQ
RQEQ 140~212
2-module systems
3-module systems
4-module systems
-
-
-
-
BHFP26P36C
BHFP26P63C
BHFP26P84C
-
-
-
-
-
-
-
KWC26B280
KWC26B450
-
KWC26B160
-
-
-
-
Central drain pan kit Installs onto the underside of the outdoor unit and collects drain water from all bottom plate outlets into a single outlet. In cold areas should be heated by a field-supplied heater to prevent drain water from freezing in the drain pan.
1 kit per module 1 kit per module
1 kit per module
Bottom plate heater kit Optional electrical heater for the VRV casing’s bottom plate to guarantee trouble-free operation even in extremely cold and humid climates
-
-
-
External control adaptor for outdoor unit DTA104A53/61/62 For installation into an indoor unit: exact adaptor type depends on type of indoor unit. See Options & Accessories of indoor units
Allows to activate Low Noise Operation and three levels of Demand Limiting via external dry contacts. Connects to the F1/F2 communication line and requires power supply from an indoor unit*, BSVQ box, or VRV-WIII outdoor unit. BHGP26A1 Digital pressure gauge kit – displays current condensing and evaporating pressures in the system as standard, or expansion valve positions and temperature sensor data in a special service mode. Connect to the outdoor unit PCB, for installation in the outdoor unit.
-
-
-
✓
1 kit per system
1 kit per system
1 kit per system
Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the A-B-C terminals of the outdoor unit / BS-box.
✓
✓
✓
-
-
-
-
KJB111A
✓
✓
✓
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KRC19-26
Installation box for remote cool/heat selector KRC19-26 BWU26A15 Water strainer kit for 1.40MPa design pressure BWU26A20 Water strainer kit for 1.96MPa design pressure
120
VRV III-C Cold Region VRV
VRV III Heat Pump
RTSYQ 10
RTSYQ 14~16
RTSYQ 20
RXYQ 5
RXYQ 8~12
RXYHQ 12
RXYQ 14~18
2-module systems
3-module systems
-
-
BHFQ22P1007
-
-
-
-
BHFQ22P1007
BHFQ22P1517
-
-
-
-
EKLD90P12
EKLD90P12
EKLD90P18
1 kit per module
1 kit per module
KWC26B280
KWC26B450
2x KWC26B280
KWC26B160
KWC26B280
KWC26B450
KWC26B450
1 kit per module
1 kit per module
BEH22A10Y1L
BEH22A18Y1L
2x BEH22A10Y1L
-
-
-
-
-
-
DTA104A53/61/62 For installation into an indoor unit: exact adaptor type depends on type of indoor unit. See Options & Accessories of indoor units
✓
✓
✓
✓
✓
✓
✓
1 kit per system
1 kit per system
-
-
-
✓
✓
✓
✓
1 kit per system
1 kit per system
-
-
-
✓
✓
✓
✓
1 kit per system
1 kit per system
VRV III-Q Heat Pump Replacement VRV
VRV-WIII Water-cooled VRV Heat Pump application Heat Recovery application 2-module 3-module 2-module 3-module systems systems systems systems
RQYQ 140
RQYQ 8~12
RQYQ 14~16
2-module systems
3-module systems
RWEYQ 8~10
-
-
-
BHFQ22P1007
BHFQ22P1517
-
BHFP22MA56
BHFP22MA84
BHFP26MA56
BHFP26MA84
-
-
-
-
-
-
-
-
-
-
KWC26B160
KWC26B280
KWC26B450
1 kit per module
1 kit per module
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
DTA104A53/61/62 For installation into an indoor unit: exact adaptor type depends on type of indoor unit. See Options & Accessories of indoor units
DTA104A62 Installation in the RWEYQ outdoor unit possible. For installation in indoor units, use appropriate type (DTA104A53/61/62) for particular indoor unit. See Options & Accessories of indoor units
✓
✓
✓
1 kit per system
1 kit per system
-
-
-
-
-
✓
✓
✓
1 kit per system
1 kit per system
✓
1 kit per system
1 kit per system
-
-
✓
✓
✓
1 kit per system
1 kit per system
1 kit per system
1 kit per system
-
-
-
-
-
-
-
1 kit per module
1 kit per module
1 kit per module
1 kit per module
-
-
-
-
-
1 kit per module
1 kit per module
1 kit per module
1 kit per module
✓ ✓ ✓
121
Options & accessories -
indoor Ceiling mounted cassette units Round flow (800x800) FXFQ 20~125
BRC1E51A Premium wired remote controller with full-text interface and back-light BRC1D52 Standard wired remote controller with weekly timer
Adaptors and Control
External wireless temperature sensor
FXZQ 15~50
FXCQ 20~32
FXCQ 40~50
✓ ✓
✓ ✓
✓ ✓
-
-
-
-
-
BRC7F532F
-
BRC7E530
BRC7C62
BRC7C62
KRCS01-4
KRCS01-4
KRCS01-1
KRCS01-1
KRCS01-1
-
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
Wiring adaptor for external monitoring/control via dry contacts and setpoint control via 0-140Ω
KRP4A53
-
KRP4A53
KRP4A51
KRP4A51
Wiring adaptor for external central monitoring/control (controls 1 entire system)
KRP2A52
KRP2A52
KRP2A52
KRP2A51
KRP2A51
EKRP1C11
KRP1C12
-
EKRP1B2
EKRP1B2
Wiring adaptor with 4 output signals Compressor / Error, Fan, Aux. heater, Humidifier output Wiring adaptor with 2 output signals
-
-
KRP1B57
-
-
Adaptor for multi-tenant applications (24VAC PCB power supply interface)
DTA114A61
DTA114A61
EKMTAC
-
-
External control adaptor for outdoor unit
DTA104A62
DTA104A62
DTA104A62
DTA104A61
DTA104A61
KRP1H98
KRP1J98
KRP1BA101
KRP1B96
KRP1B96
Connector for forced-off contact
Standard
Standard
Standard
Standard
Standard
Connection to centralized control
Standard
Standard
Standard
Standard
Standard
Compressor / Error, Fan output
Installation box / Mounting plate for adaptor PCBs For units where there is no space in the switchbox
Decoration panel (obligatory for cassette units, optional for others, rear panel for FXLQ)
Others
2-way blow
✓
Simplified wired remote controller External wired temperature sensor
FXFQ 20~125 with autocleaning
✓ ✓
BRC2C51 Infra-red remote controller including receiver
4-way (600x600)
BYCQ140C(W)
BYCQ140CG
BYFQ60B
BYBC32G
BYBC50G
Kit for mounting of decoration panel direct onto unit
-
-
-
-
-
Panel spacer for reducing required installation height
-
-
KDBQ44B60
-
-
KDBHQ55C140
KDBHQ55C140
KDBH44BA60
-
-
CE.KDDQ55C140
-
KDDQ44XA60
-
-
-
-
-
-
-
Sealing kit for 3-directional or 2-directional air discharge Fresh air intake kit Air discharge adaptor for round duct Replacement long life filter Drain pump kit
KAFP551K160
-
-
-
-
Standard
Standard
Standard
Standard
Standard
Concealed ceiling units (duct units) High ESP BRC1E51A Premium wired remote controller with full-text interface and back-light BRC1D52 Standard wired remote controller with weekly timer BRC2C51
Adaptors and Control
Simplified wired remote controller
FXMQ 40
FXMQ 50~80
FXMQ 100~125
FXMQ 200~250
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
Infra-red remote controller including receiver
BRC4C65
BRC4C65
BRC4C65
BRC4C65
BRC4C65
External wired temperature sensor
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-1
External wireless temperature sensor
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
Wiring adaptor for external monitoring/control via dry contacts and setpoint control via 0-140Ω
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP4A51
Wiring adaptor for external central monitoring/control (controls 1 entire system)
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP2A51
Wiring adaptor with 4 output signals
EKRP1B2
EKRP1B2
EKRP1B2
EKRP1B2
KRP1B61
-
-
-
-
-
Adaptor for multi-tenant applications (24VAC PCB power supply interface)
DTA114A61
DTA114A61
DTA114A61
DTA114A61
-
External control adaptor for outdoor unit
DTA104A61
DTA104A61
DTA104A61
DTA104A61
DTA104A61
KRP4A96
KRP4A96
KRP4A96
KRP4A96
-
Connector for forced-off contact
Standard
Standard
Standard
Standard
Standard
Connection to centralized control
Standard
Standard
Standard
Standard
Standard
Compressor / Error, Fan, Aux. heater, Humidifier output Wiring adaptor with 2 output signals Compressor / Error, Fan output
Installation box / Mounting plate for adaptor PCBs For units where there is no space in the switchbox
Others
Large
FXMQ 20~32
Decoration panel (obligatory for cassette units, optional for others, rear panel for FXLQ)
BYBS32D
BYBS45D
BYBS71D
BYBS125D
-
Kit for mounting of decoration panel direct onto unit
EKBYBSD
EKBYBSD
EKBYBSD
EKBYBSD
-
Panel spacer for reducing required installation height
-
-
-
-
-
Sealing kit for 3-directional or 2-directional air discharge
-
-
-
-
-
Fresh air intake kit
-
-
-
-
-
KDAJ25K36A
KDAJ25K56
KDAJ25K71
KDAJ25K140
-
Air discharge adaptor for round duct Replacement long life filter Drain pump kit
122
-
-
-
-
-
Standard
Standard
Standard
Standard
-
Ceiling mounted cassette units 2-way blow
Concealed ceiling units (duct units)
Corner (1-way blow)
Small
Slim
Standard
FXCQ 63
FXKQ 25~40
FXKQ 63
FXDQ 20~25 M9
FXDQ 15~63 P7
FXSQ 20~32
FXSQ 40~50
FXSQ 63~80
FXSQ 100~140
✓ ✓
✓ ✓
✓ ✓
-
-
-
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
BRC7C62
BRC4C61
BRC4C61
BRC4C62
BRC4C65
BRC4C65
BRC4C65
BRC4C65
BRC4C65
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-4
KRCS01-4
KRCS01-4
KRCS01-4
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP4A54
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP2A61
KRP2A61
KRP2A51
KRP2A51
KRP2A51
EKRP1B2
KRP1B61
KRP1B61
EKRP1B2
-
EKRP1B2
EKRP1B2
EKRP1B2
EKRP1B2
-
-
-
-
KRP1B56
-
-
-
-
-
-
-
EKMTAC
EKMTAC
DTA114A61
DTA114A61
DTA114A61
DTA114A61
DTA104A61
DTA104A61
DTA104A61
DTA104A61
DTA104A53
DTA104A61
DTA104A61
DTA104A61
DTA104A61
KRP1B96
-
-
-
KRP1BA101
KRP4A96
KRP4A96
KRP4A96
KRP4A96
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
BYBC63G
BYK45F
BYK71F
-
-
BYBS32D
BYBS45D
BYBS71D
BYBS125D
-
-
-
-
-
EKBYBSD
EKBYBSD
EKBYBSD
EKBYBSD
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KDAJ25K36A
KDAJ25K56
KDAJ25K71
KDAJ25K140
-
-
-
-
-
-
-
-
-
Standard
Standard
Standard
-KDAJ25K56
Standard
Standard
Standard
Standard
Standard
Ceiling suspended units 1-way blow
Wall mounted units 4-way blow
Floor standing units Concealed
Free-standing
FXHQ 32
FXHQ 63~100
FXUQ 71
FXUQ 100~125
FXAQ 15~63
FXNQ 20~63
FXLQ 20~25
FXLQ 32~40
FXLQ 50~63
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
-
-
-
-
-
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
✓ ✓ ✓
BRC7E63
BRC7E63
BRC7C528
BRC7C528
BRC7E618
BRC4C65
BRC4C65
BRC4C65
BRC4C65
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
KRCS01-1
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP4A52
KRP4A52
KRP4A53
KRP4A53
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP4A51
KRP2A52
KRP2A52
-
-
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP2A51
KRP1B3
KRP1B3
-
-
-
KRP1B61
KRP1B61
KRP1B61
KRP1B61
-
-
-
-
-
-
-
-
-
DTA114A61
DTA114A61
-
-
DTA114A61
EKMTAC
EKMTAC
EKMTAC
EKMTAC
DTA104A62
DTA104A62
-
-
DTA104A61
-
-
-
-
KRP1C93
KRP1C93
KRP1B97
KRP1B97
KRP4A93
-
-
-
-
Standard
Standard
EKRORO
EKRORO
Standard
Standard
Standard
Standard
Standard
Standard
Standard
DTA102A52
DTA102A52
Standard
Standard
Standard
Standard
Standard
-
-
-
-
-
-
EKRDP25
EKRDP40
EKRDP63
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KDU50M60
KDU50M125
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KDU50M60
KDU50M125
Standard
Standard
K-KDU572EVE
-
-
-
-
123
Ventilation Refrigerant Distribution
Options & accessories -
Heat Reclaim Ventilation
100% freshair unit
With DX coil VAM 150~2000 BRC1E51A Premium wired remote controller with full-text interface and back-light BRC1D52 Standard wired remote controller with weekly timer BRC301B61 Wired remote controller for HRV
Adaptors and Control
BRP4A50 Control kit for auxiliary 3rd party heater KRP50-2 Adaptor PCB for 3rd party humidifier control / for operation signal output External wired temperature sensor Wiring adaptor for external monitoring/control via dry contacts and setpoint control via 0-140Ω Wiring adaptor for external central monitoring/ control (controls 1 entire system)
✓ ✓ ✓ ✓ ✓
Biddle air curtains
AHU application control boxes
For VRV
For ERQ
For VRV
For ERQ
CYV-DK-
CYQ-DK-
EKEQMCB
EKEQDCB
EKEQFCB
VKM 50
VKM 80~100
FXMQ 125~250 MF
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
-
-
-
-
-
-
-
-
✓ ✓
✓ ✓
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KRCS01-1
KRCS01-1
-
-
-
-
KRP4A51
-
-
KRP4A51
KRP4A51
-
KRP2A61
KRP2A61
KRP2A61
KRP2A61
-
-
-
-
-
-
-
-
KRP1B61
-
-
-
-
-
-
-
-
DTA104A61
-
-
DTA104A61
DTA104A61
Ask your Daikin representative
Wiring adaptor with 4 output signals Compressor / Error, Fan, Aux. heater, Humidifier output External control adaptor for outdoor unit Allows to activate Low Noise Operation and three levels of Demand Limiting via external dry contacts. Installation box / Mounting plate for adaptor PCBs
KRP1B93
KRP1B93
KRP1B93
-
-
-
-
-
-
Standard
Standard
Standard
Standard
Standard
-
-
-
-
Silencer for 250 mm round duct
-
-
KDDM24B100
-
-
-
-
-
-
Drain pump kit
-
-
-
-
-
-
-
-
-
For units where there is no space in the switchbox
Others
Connection to centralized control
Refnet Joints
Heat Pump systems (2-pipe)
Heat Recovery systems (3-pipe)
Metric-size connections Imperial-size connections Sound reduction kit (sound insulation) Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the A-B-C terminals of the outdoor unit / BS-box. Installation box for remote cool/heat selector KRC19-26
Metric-size connections
Imperial-size connections
Refnet Headers
Capacity index < 201
Capacity index 201~290
Capacity index 291~640
Capacity index > 640
Capacity index < 291
Capacity index 291~640
Capacity index > 640
KHRQM23M20T
KHRQM23M29T
KHRQM23M64T
KHRQM23M75T
KHRQM23M29H
KHRQM23M64H
KHRQM23M75H
KHRQ23M20T
KHRQ23M29T9
KHRQ23M64T
KHRQ23M75T
KHRQ23M29H
KHRQ23M64H
KHRQ23M75H
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KHRQM22M20T
KHRQM22M29T
KHRQM22M64T
KHRQM22M75T
KHRQM22M29H
KHRQM22M64H
KHRQM22M75H
KHRQ22M20T
KHRQ22M29T9
KHRQ22M64T
KHRQ22M75T
KHRQ22M29H
KHRQ22M64H
KHRQ22M75H
124
Hot water heating unit for VRV
Inverter Heat Pump Condensing Units
HXHD125A EKRP1HBAA
ERQ 125 AW1
ERQ 200~250 AW1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
✓ ✓
✓ ✓
✓ ✓
-
KWC26B160
KWC26B280
✓ ✓ ✓ ✓ ✓ ✓
Digital I/O PCB EKRP1AHTA Demand PCB - Required to install to be able to connect Room thermostat EKRUAHTB
Adaptors and Control
ERQ 100~140 AV1
Remote user interface [remocon] - Same controller as supplied with Cascade unit can be mounted parallel or on other location. If 2 controllers are installed, the installer needs to select 1 master & 1 slave EKRTWA Wired Room thermostat - Requires Demand PCB EKRP1AHTA EKRTR1 Wireless Room thermostat - Requires Demand PCB EKRP1AHTA EKRTETS Remote sensor for Room thermostat - Requires Demand PCB EKRP1AHTA KRC19-26 Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the A-B-C terminals of the outdoor unit / BS-box.
-
KJB111A
-
Installation box for remote cool/heat selector KRC19-26
Others
Central drain pan kit
Installs onto the underside of the outdoor unit and collects drain water from all bottom plate outlets into a single outlet. In cold areas should be heated by a field-supplied heater to prevent drain water from freezing in the drain pan.
-
Heat Recovery Branch Selector Boxes (BS-Boxes) 1-port Capacity index < 101
1-port Capacity index 101 ~ 160
1-port Capacity index 161 ~ 250
4-port Capacity index < 100 per port
6-port Capacity index < 100 per port
2-port For Split and SkyAir indoor units
External Expansion Valve Boxes (BP- / BEV- boxes) 3-port For Split and 1-port 1-port SkyAir indoor For FXUQ 71 For FXUQ 100 units
1-port For FXUQ 125
-
-
-
-
-
-
-
-
-
-
BSVQ100P8B
BSVQ160P8B
BSVQ250P8B
BSV4Q100PV
BSV6Q100PV
-
-
BEVQ71MA
BEVQ100MA
BEVQ125MA
EKBSVQLNP
EKBSVQLNP
EKBSVQLNP
-
-
-
-
-
-
-
-
-
-
-
-
KRC19-26
KRC19-26
1 kit per port necessary
1 kit per port necessary
KRC19-26
KRC19-26
KRC19-26
KJB111A
KJB111A
KJB111A
KJB111A
KJB111A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
BPMKS967A2
BPMKS967A3
BEVQ71MA
BEVQ100MA
BEVQ125MA
125
MEASURING CONDITIONS AIR CONDITIONING 1) nominal cooling capacities are based on: Indoor temperature Outdoor temperature Refrigerant piping length Level difference 2) nominal heating capacities are based on: Indoor temperature Outdoor temperature Refrigerant piping length Level difference
27°CDB/19°CWB 35°CDB 7.5m - 8/5m VRV 0m 20°CDB 7°CDB/6°CWB 7.5m - 8/5m VRV 0m
The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment (for measuring conditions: please refer to the technical databooks). The sound power level is an absolute value indicating the “power” which a sound source generates. For more detailed information please consult our technical databooks.
126
® VRV
Catalogue ■
DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH campus 21, Europaring F12/402, A – 2345 Brunn/Gebirge Tel.: +43 / 22 36 / 3 25 57-0, Fax: +43 / 22 36 / 3 25 57-900 e-mail: office@daikin.at, www.daikin-ce.com
The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V./Daikin Central Europe HandelsGmbH. Daikin Europe N.V./Daikin Central Europe HandelsGmbH has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V./Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
Daikin products are distributed by:
ECPEN12_02_dace_VRV • Copyright Daikin We reserve the right for printing errors and model changes.
V R V ® C ATA LO G U E 2 012
Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.
ALL SEASONS PERFECT C MFORT
2012