Illume Capitol Yards - 100% Design-Build Package

Page 1

ILLUME CAPITOL YARDS

WAYFINDING & SIGNAGE PROGRAM

DESIGN-BUILD PACKAGE - POST FINAL REVISED PROJECT AREA STATUS

EXTERIOR SIGNAGE 100% PARKING GARAGE SIGNAGE 100% BUILDINGS 2 AND 3 SIGNAGE 100%

PREPARED BY: GABLE DESIGN STUDIO DATE: 04.21.2021 DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION

Project No. 86822


Contents 1. Project Overview Project Contacts 1.01 Project Summary 1.01 2. Graphic Standards Colors, Materials, and Finishes Typefaces, Arrows, and Symbols 3. Sign Families and Quantities Exterior Signs & Quantities Parking Garage Signs & Quantities Building 2 - Wayfinding Signs & Quantities Building 2 - Code Signs & Quantities Building 3 - Wayfinding Signs & Quantities Building 3 - Code Signs & Quantities

2.01 2.02 3.01 3.02 3.03 3.04 3.05 3.06

4. Exterior - Sign Details E5-01 - Site Monument ID E2 - Primary Building Mounted ID E11 - Vehicular Directional E10-1 - Pedestrian Directional E10-2 - Pedestrian Directional E1 - Exterior Garage Entrance/Exit E3 - Secondary Building Mounted ID

4.01-4.02 4.03 4.04 4.05 4.06-4.07 4.08 4.09-4.10

5. Parking Garage - Sign Details G1 - Overhead Directional 5.01-5.05 G2 - Wall Directional 5.06-5.07 2JG - Garage Elevator ID 5.08 6. Buildings 2 and 3 - Sign Details 2Ma - Directional (large) 6.01-6.02 2Mb - Directional (small) 6.03-6.05 2P - Elevator Directory 6.06 2N - Flag ID (Double-Sided) 6.07-6.08 2L - Suite ID 6.10 2K - Amenity ID 6.11 2F - Restroom ID 6.12 2A - Stair ID 6.13 2J - Room ID (FOH) 6.14 2H - Room ID (BOH) 6.15 2D - Exit ID 6.16 2G - Max Occupancy 6.17 2E - Evac/In Case of Fire 6.18 2C - Egress Directional 6.19 3Ma - Directional (large) 6.21-6.26 3Mb - Directional (small) 6.27-6.31 3P - Elevator Directory 6.32 3N - Flag ID (Double-Sided) 6.33-6.34 3L - Suite ID 6.36 3K - Amenity ID 6.37 3F - Restroom ID 6.38 3A - Stair ID 6.39 3J - Room ID (FOH) 6.40 3H - Room ID (BOH) 6.41 3D - Exit ID 6.42 3G - Max Occupancy 6.43 3E - Evac/In Case of Fire 6.44 3C - Egress Directional 6.45 7. Buildings 2 and 3 - Select Mounting Elevations Building 2 - Select Mounting Elevations 7.01-7.02 Building 3 - Select Mounting Elevations 7.03-7.05

8. Exterior - Sign Locations and Messages Exterior 8.01-8.04 9. Parking Garage - Wayfinding Sign Locations P1 Parking Level 9.01 P2 Parking Level 9.02 10. Parking Garage - Code Sign Locations and Messages P1 Parking Level 10.01-10.04 P2 Parking Level 10.05-10.06 11. Buildings 2 and 3 - Wayfinding Sign Locations Ground Floor 11.01 Second Floor 11.02 Third Floor 11.03 Fourth Floor 11.04 Fifth Floor 11.05 Sixth Floor 11.06 Seventh Floor 11.07 Eighth Floor 11.08 Ninth Floor 11.09 Tenth Floor 11.10 Eleventh Floor 11.11 Twelfth Floor 11.12 Thirteenth Floor 11.13 Rooftop Floor 11.14 12. Buildings 2 and 3 - Code Sign Locations and Messages Ground Floor 12.01-12.08 Second Floor 12.09-12.14 Third Floor 12.15-12.20 Fourth Floor 12.21-12.26 Fifth Floor 12.27-12.32 Sixth Floor 12.33-12.38 Seventh Floor 12.39-12.44 Eighth Floor 12.45-12.50 Ninth Floor 12.51-12.56 Tenth Floor 12.57-12.62 Eleventh Floor 12.63-12.68 Twelfth Floor 12.69-12.74 Thirteenth Floor 12.75-12.79 Rooftop Floor 12.80-12.85 13. Appendix Reviewing Programming 13.01


1

Project Overview


Project Contacts

Project Summary

7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Owner Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Environmental Graphic Design Gable 7440 Fort Smallwood Road Baltimore, MD 21226 410.255.6400

Project Description Planning and design of a new signage and wayfinding system for the Illume Capitol Yards development project in Washington, DC. Project includes an 11-acre site, 750 unit residential buildings, a co-working facility, and sub-level parking.

Mary Grace Hinkle Development Associate marygrace.hinkle@greystar.com

Jack Hulme, LEED GA Creative Director, Environmental Graphic Design Studio jackhulme@gablecompany.com

Open Items General Items: • All sign details, sign locations, and sign messages require Owner Approval see “Client Required Approval” on each drawing sheet

DOCUMENT NAME / SUBMITTAL DATE

Brandi McGonigal Senior Project Manager brandimcgonigal@gablecompany.com

Exterior Items: • Color selection for Site Monument ID signs is pending Owner Approval • Trade coordination required for mounting bolts of Site Monument ID sign located on I Street • Pedestrian Directionals (E10-2) required foam board mock-ups for final size and placement • Parking Garage Entrance letters (Building 3 and Hotel) are placeholder only and are to be finalized once building construction is further developed

NOTE

Architect R2L Architects, PLLC 3222 N Street NW, Suite 500 Washington, DC 20007 202-600-7232 Sacha Rosen Principal srosen@r2l-architects.com General Contractor John Moriarty & Associates of Virginia, LLC 861 New Jersey Avenue SE Washington, DC 20003 717-586-7426 Hunter Klein hklein@jm-a.com

Ross Hancock Senior Vice President rosshancock@gablecompany.com

Parking Garage Items: • Overhead directionals require technical field survey to assess mounting requirements for all locations • Elevator ID Graphics are placeholder only and are to be finalized after garage painting is completed (garage painting by others) Revisions Exterior Items: • Per Owner email dated 04/20/2021, add “ILLUME” lettering to second side of Sign Type E5-01, Site Monument ID • Per Owner email dated 04/20/2021, deleted Sign Type E5-02, Site Monument ID • Per Owner email dated 04/20/2021, change typestyle of Sign Type E1, Exterior Garage Entrance/Exit from Gibson Light to Gibson SemiBold

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Project Contacts and Project Summary

JH

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

1 Project Overview

1.01


2

Graphic Standards


Colors, Materials, and Finishes

7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Color Symbol

Specification (Color to Match)

Substrate

Application Process

P1

MFBB Blackened Aluminum (www.Carvart.com)

Aluminum Acrylic

Painted, Suede Matte Finish

P2

MFMN Midnight (www.Carvart.com)

Aluminum Acrylic

Painted, Suede Matte Finish

P3

PMS 722 C

P4

MP 40684 Rosy Copper Metallic

Aluminum

Painted, Semi-gloss Metallic Finish

P5

SW 6510 Loyal Blue

Aluminum

Painted, Semi-gloss Finish

Raised Copy

3D Printed

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Colors, Materials, and Finishes

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

NOTE

F1

Coppertone

Aluminum

Specialty Finish

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

V1

PMS 722 C

Aluminum

Applied Matte Vinyl

V2

White

CMU Block and Concrete

Applied Matte Vinyl (heat formed to wall surface)

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

2 Graphic Standards

2.01


Typefaces, Arrows, and Symbols

7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Gibson - REGULAR (25 pt. Tracking)

Gibson - LIGHT (25 pt. Tracking)

ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 01213456789!@#$%^&*()_+-=

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 01213456789!@#$%^&*()_+-=

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Typeface, Arrows, and Symbols

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

LEFT ARROW

UP-LEFT ARROW

STRAIGHT ARROW

UP-RIGHT ARROW

RIGHT ARROW

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

STAIR SYMBOL

MALE / ACCESSIBLE SYMBOL

FEMALE / ACCESSIBLE SYMBOL

ACCESSIBLE SYMBOL

ALL GENDER SYMBOL

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

IN CASE OF FIRE SYMBOL

ELEVATOR SYMBOL

MAIL ROOM SYMBOL

BIKE ROOM SYMBOL

SECTION

SHEET NO.

2 Graphic Standards

2.02


3

Sign Families and Quantities


Exterior Signs & Quantities

7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Exterior Signs

JH

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Sign Type: E2 Primary Building Mounted ID Qty: 02

Sign Type: E5-1 Site Monument ID Qty: 01

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

PARKING HOTEL VALET PARKING GARAGE ALL DELIVERIES

Sign Type: E11 Vehicular Directional Qty: 02

BUILDING 3 DOG PARK

Sign Type: E10-1 Pedestrian Directional Qty: 01

DOG PARK BUILDING 2 HOTEL

BUILDING 2 CONNECTOR

BUILDING 3 RESIDENT LOUNGE BUSINESS CENTER

Sign Type: E10-2 Pedestrian Directional Qty: 03

Sign Type: E1 Exterior Garage Entrance/Exit Qty: 02

Sign Type: E3 Secondary Building Mounted ID Qty: 07

SECTION

SHEET NO.

3 Sign Families & Quantities

3.01


Parking Garage Signs & Quantities

7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

PARK Sign Type: G1 - Overhead Directional Qty: 20

TO BUILDING 3 ELEVATORS TO BUILDING 2 ELEVATORS

TO CAPITAL YARDS STAIRS

Sign Type: G2 - Wall Directional Qty: 10

EXIT

B3 Sign Type: G3 - Garage Elevator ID Qty: 12

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Parking Garage Signs

JH

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

3 Sign Families & Quantities

3.02


Building 2 - Wayfinding Signs & Quantities

7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Building 2 - Wayfinding Signs

JH

NOTE

Sign Type: 2N - Flag ID (Double-Sided) Qty: 07 Sign Type: 2Mb - Directional (small wall-mounted) Qty: 24

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

Sign Type: 2P - Elevator Directory Qty: 17

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Sign Type: 2Ma - Directional (large wall-mounted) Qty: 1

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

3 Sign Families & Quantities

3.03


Building 2 - Code Signs & Quantities

7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

Sign Type: 2J - Room ID (FOH) Qty: 87 Sign Type: 2L - Suite ID Qty: 214

Sign Type: 2K - Amenity ID Qty: 8

Sign Type: 2F - Restroom ID Qty: 20

Sign Type: 2A - Stair ID Qty: 34

DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Building 2 - Code Signs

JH

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

STAIR 2-1

IRRIGATION PUMP FILTER ROOM

Sign Type: 2H - Room ID (BOH) Qty: 40

MAX OCCUPANCY ###

EXIT FIRE ROUTE

Sign Type: 2D - Exit ID Qty: 13

Sign Type: 2G - Max Occupancy Qty: 10

IN CASE OF FIRE USE STAIRS

Sign Type: 2E - Evac/In Case of Fire Qty: 23

ROOF ACCESS

LEVEL

3

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

DOWN TO FLOOR 1 FOR EXIT DISCHARGE LEVELS P1-12 Sign Type: 2C - Egress Direction Qty: 29

SECTION

SHEET NO.

3 Sign Families & Quantities

3.04


Building 3 - Wayfinding Signs & Quantities

7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Sign Type: 3N - Flag ID (Double-Sided) Qty: 13 Sign Type: 3Mb - Directional (small wall-mounted) Qty: 46

04.21.2021

SHEET NAME

DRAWN BY

Building 3 - Wayfinding Signs

JH

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Sign Type: 3P - Elevator Directory Qty: 28

Sign Type: 3Ma - Directional (large wall-mounted) Qty: 30

Design-Build Package - POST FINAL REVISED

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

3 Sign Families & Quantities

3.05


Building 3 - Code Signs & Quantities

7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Sign Type: 3L - Suite ID Qty: 542

Sign Type: 3J - Room ID (FOH) Qty: 123 Sign Type: 3K - Amenity ID Qty: 12

Sign Type: 3F - Restroom ID Qty: 16

Sign Type: 3A - Stair ID Qty: 75

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Building 3 - Code Signs

JH

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

STAIR 2-1

IRRIGATION PUMP FILTER ROOM

Sign Type: 3H - Room ID (BOH) Qty: 43

EXIT FIRE ROUTE

Sign Type: 3D - Exit ID Qty: 17

IN CASE OF FIRE USE STAIRS

Sign Type: 3E - Evac/In Case of Fire Qty: 54

MAX OCCUPANCY ###

Sign Type: 3G - Max Occupancy Qty: 12

ROOF ACCESS

LEVEL

3

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

DOWN TO FLOOR 1 FOR EXIT DISCHARGE LEVELS P1-12 Sign Type: 3C - Egress Direction Qty: 65

SECTION

SHEET NO.

3 Sign Families & Quantities

3.06


4

Sign Drawings - Exterior


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: E5-01 - SITE MONUMENT ID

Scale: 1/4”= 1’-0”

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. A Material: 0.375” thk aluminum panels, routed, v-grooved, perforated, and bent as shown Background Process: Surface painted - all areas Color: As noted Mounting Method: Anchor bolts to concrete curb, provide spacer between curb and panel for water displacement B Product: Cut dimensional letters (both faces) Size: 9“ and 2.25” Color: As noted Mounting Method: Pin-mount to panel w/ non-corrosive connection NOTE: FINAL COLOR PENDING OWNER APPROVAL NOTE: PROVIDE GC WITH ANCHOR BOLT TEMPLATE

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: E5-01 - Site Monument ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

NOTE

30’-0” VIF - MUST EQUAL LENGTH OF SWM UNITS AS SHOWN ABOVE

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

B P5

3’-7”

2’-2”

A P4

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Front Elevation Location: E5-01

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

7 Sign Elevations - Exterior

4.01


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: E5-01 - SITE MONUMENT ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1/4”= 1’-0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: E5-01 - Site Monument ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

Sheet #1 Panel Size: 8’ x 16’

APPROVED

Sheet #2 Panel Size: 8’ x 16’

REVISE AND RESUBMIT APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

30’-0” VIF B P5

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

3’-7”

2’-2”

A P4

Rear Elevation Location: E5-01

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

7 Sign Elevations - Exterior

4.02


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: E2 - PRIMARY BUILDING MOUNTED ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: As Noted

A Product: “Edgelit Design 100” Letter by Steel Art Finish: Copper - Brushed Satin Return Depth: 1“ D with 2” D visible illuminated acrylic edge B Rivet-Nut in Letter Back w/ Threaded Rod Mount 1/2“ spacer for letter offset Use silicone sealant at all penetrations

8’-0”

1’-4”

Product Reference

A

Front Elevation - Scale: 1/16” - 1”

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

C LED Wiring Use wireways in existing canopy structure for Linear Light Fixtures to run wire leads to remote Power Pack.

SHEET NAME

DRAWN BY

Sign Type: E2 - Primary Building Mounted ID

JH

D Linear Light Fixtures - by GC Installed along HSS Canopy Structural Members

SUBMITTAL: DATE:

CLIENT REQUIRED APPROVAL

REVIEWED BY: APPROVED REVISE AND RESUBMIT

Canopy Paint Color

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

Align A B

C

D

Side Section - Scale: 1/8” - 1”

Align

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

7 Sign Elevations - Exterior

4.03


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: E11 - VEHICULAR DIRECTIONAL

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1”= 1’-0”

A Material: 3”x3“ internal aluminum frame, clad all sides w/ 0.125” thk aluminum and grind all welds smooth for smooth continuous surface Background Process: Surface painted - all areas Color: As noted Mounting Method: Sub-grade anchor plate to concrete footer (Not Shown) B Material: Screen printed copy and arrow (single-face) Color: As noted Typeface: Gibson - Light Cap Height: 3” Cap Height Case: Upper Case Tracking: 25 pt.

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: E11 - Vehicular Directional

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE:

4’-0”

REVIEWED BY:

3”

APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

A P5

4’-0”

NOTE

HOTEL VALET PARKING GARAGE ALL DELIVERIES

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

PARKING GARAGE ALL DELIVERIES

B P4

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Front Elevation Location: E11.01

Side Elevation

Front Elevation Location: E11.03

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

7 Sign Elevations - Exterior

4.04


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: E10-1 - PEDESTRIAN DIRECTIONAL

Scale: 1”= 1’-0”

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. A Material: 3”x3“ internal aluminum frame, clad all sides w/ 0.125” thk aluminum and grind all welds smooth for smooth continuous surface Background Process: Surface painted - all areas Color: As noted Mounting Method: Sub-grade anchor plate to concrete footer (Not Shown) B Material: Screen printed copy and arrow (double-face) Color: As noted Typeface: Gibson - Light Cap Height: 1.5” Cap Height Case: Upper Case Tracking: 25 pt.

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: E10-1 - Pedestrian Directional

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE:

2’-0”

REVIEWED BY:

3”

APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

A P5

NOTE

LEASING OFFICE METRO STATION CAPITOL YARDS CONNECTOR

B P4

4’-0”

BUILDING 3 DOG PARK

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Front Elevation Location: E10-1 (side a)

Side Elevation

Front Elevation Location: E10-1 (side b)

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

7 Sign Elevations - Exterior

4.05


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: E10-2 - PEDESTRIAN DIRECTIONAL

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1”= 1’-0”

A Material: 0.375” thk aluminum, routed, v-grooved, perforated, and bent as shown Background Process: Surface painted - all areas Color: As noted Mounting Method: Stud-mount to planter wall face B Material: Screen printed copy and arrow (single-face) Color: As noted Typeface: Gibson - Light Cap Height: 1.5” Cap Height Case: Upper Case Tracking: 25 pt. NOTE: COORDINATE FINAL LOCATION WITH SECURITY GATE (NOT SHOWN) 4” MAX.

4’-0”

NOTE: PROVIDE FULL-SIZE FOAM BOARD MOCK-UPS OF VARIOUS PANEL SIZES FOR FINAL PLACEMENT AND SIZE APPROVAL

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: E10-2 - Pedestrian Directional

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

A P5

2’-0”

DOG PARK BUILDING 2 HOTEL

BUILDING 3 RESIDENT LOUNGE BUSINESS CENTER

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

B P4

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

Reference Image of Planter Wall Location E10-2.02 on Left

Front Elevation Location: E10-2

Side Elevation

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

7 Sign Elevations - Exterior

4.06


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: E10-2 - PEDESTRIAN DIRECTIONAL

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1”= 1’-0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

BUILDING 3 RESIDENT LOUNGE BUSINESS CENTER

BUILDING 2 FITNESS CENTER DOG PARK

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: E10-2 - Pedestrian Directional

JH

CLIENT REQUIRED APPROVAL

HOTEL

BUILDING 2 FITNESS CENTER LEASING OFFICE

SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

Graphic Layout Location: E10-2.01

Graphic Layout Location: E10-2.02

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

DOG PARK BUILDING 2 HOTEL

Graphic Layout Location: E10-2.03

BUILDING 3 RESIDENT LOUNGE BUSINESS CENTER

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

7 Sign Elevations - Exterior

4.07


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: E2 - PRIMARY BUILDING MOUNTED ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: As Noted

A Product: “Edgelit Design 100” Letter by Steel Art Finish: Copper - Brushed Satin Return Depth: 1“ D with 2” D visible illuminated acrylic edge B Rivet-Nut in Letter Back w/ Threaded Rod Mount 1/2“ spacer for letter offset Use silicone sealant at all penetrations

1’-0”

6’-3”

PARKING

Product Reference

A

Front Elevation - Scale: 1/16” - 1”

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

C LED Wiring Use wireways in existing canopy structure for Linear Light Fixtures to run wire leads to remote Power Pack.

SHEET NAME

DRAWN BY

Sign Type: E1-01 - Exterior Garage Entrance/Exit

JH

D Linear Light Fixtures - by GC Installed along HSS Canopy Structural Members

SUBMITTAL: DATE:

CLIENT REQUIRED APPROVAL

REVIEWED BY:

NOTE: FINAL LOCATION AND SIZE TO BE DETERMINED ONCE CONSTRUCTION HAS PROGRESSED MORE

APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

Building 3 Entrance

Hotel Valet Entrance

Hotel Valet Entrance

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

7 Sign Elevations - Exterior

4.08


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: E3 - SECONDARY BUILDING MOUNTED ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

1' 1.50" EQ.

EQ.

A P5

B Screen Printed Copy Color: As noted Typeface: Gibson - Light Cap Height: 1.25” Cap Height Case: Upper Case Tracking: 25 pt.

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: E3 - Secondary Building Mounted ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

BUILDING 3

1.625"

10.50"

5"

C Material: .063” D/F Tape and silicone

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

APPROVED REVISE AND RESUBMIT

B P4

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

C

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

Front Elevation Location E3.08 Shown

Side Elevation

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

7 Sign Elevations - Exterior

4.09


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: E3 - SECONDARY BUILDING MOUNTED ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1:4

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

LEASING OFFICE

BUILDING 3 CONNECTOR

FITNESS CENTER

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: E3 - Secondary Building Mounted ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

Graphic Layout Location: E3.01

Graphic Layout Location: E3.03

Graphic Layout Locations: E3.04 and E3.07

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

BUSINESS CENTER

PET SPA

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Graphic Layout Location: E3.05

Graphic Layout Location: E3.06

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

7 Sign Elevations - Exterior

4.10


5

Sign Drawings - Parking Garage


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: G1 - OVERHEAD DIRECTIONAL

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1”= 1’-0”

A Material: 6mm Compbond Background Process: Surface painted Color: As noted Edges: Painted to match face Mounting Method: Cable suspended w/ quicklink attachment (see photo) B Material: Applied matte vinyl (both faces) Color: As noted Typeface: Gibson - Light Cap Height: 6” Cap Height Case: Upper Case Tracking: 25 pt. NOTE: TECHNICAL FIELD SURVEY IS REQUIRED TO DETERMINE APPROPRIATE MOUNTING METHOD. GARAGE INCLUDES CONCRETE CEILING AND DROP CEILING.

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: G1 - Overhead Directional

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

8’-0”

9”

PARK Front Elevation

EXIT

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

A P7 B

V1

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

Side Elevation

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

6 Sign Elevations - Parking Garage

5.01


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: G1 - OVERHEAD DIRECTIONAL

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1”= 1’-0”

LEVEL P2 Graphic Layout Location: G1.01

PARK Side A

EXIT Graphic Layout Location: G1.01

Side B

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: G1 - Overhead Directional

JH

CLIENT REQUIRED APPROVAL

PARK Graphic Layout Location: G1.02

EXIT Side A

PARK Graphic Layout Location: G1.03

Graphic Layout Location: G1.04

Side A

Side A

Side A

APPROVED REVISE AND RESUBMIT

PARK Side B

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

LEVEL P2 Side B

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

B2 Graphic Layout Location: G1.05

REVIEWED BY:

Side B

EXIT Graphic Layout Location: G1.04

EXIT

B3

EXIT Graphic Layout Location: G1.03

EXIT

PARK Graphic Layout Location: G1.05

Graphic Layout Location: G1.02

B2

PARK

LEVEL P2

SUBMITTAL: DATE:

B3 Side B

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

6 Sign Elevations - Parking Garage

5.02


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: G1 - OVERHEAD DIRECTIONAL

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1”= 1’-0”

PARK Graphic Layout Location: G1.06

EXIT Side A

B3 Graphic Layout Location: G1.06

B2 Side B

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: G1 - Overhead Directional

JH

CLIENT REQUIRED APPROVAL

PARK Graphic Layout Location: G1.07

EXIT Side A

Graphic Layout Location: G1.07

B2 ONLY Graphic Layout Location: G1.08

Graphic Layout Location: G1.10

Graphic Layout Location: G1.09

EXIT Side A

Side A

APPROVED REVISE AND RESUBMIT

EXIT Side B

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

Side B

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

EXIT Graphic Layout Location: G1.11

REVIEWED BY:

Side B

EXIT Graphic Layout Location: G1.10

EXIT Graphic Layout Location: G1.11

B2

PARK

Side A

B2

B3

SUBMITTAL: DATE:

B2 Side B

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

6 Sign Elevations - Parking Garage

5.03


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: G1 - OVERHEAD DIRECTIONAL

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1”= 1’-0”

EXIT Graphic Layout Location: G1.12

Side A

B2 Graphic Layout Location: G1.12

Side B

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: G1 - Overhead Directional

JH

CLIENT REQUIRED APPROVAL

EXIT Graphic Layout Location: G1.13

Side A

OFFICE PARKING Graphic Layout Location: G1.13

EXIT Graphic Layout Location: G1.14

Side A

EXIT Graphic Layout Location: G1.15

Side A

PARK Graphic Layout Location: G1.16

Side B

PARK

EXIT Side B

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

PARK Graphic Layout Location: G1.16

APPROVED AS NOTED

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

EXIT Side A

APPROVED REVISE AND RESUBMIT

OFFICE ONLY

Graphic Layout Location: G1.15

REVIEWED BY:

Side B

Graphic Layout Location: G1.14

LEVEL P2

SUBMITTAL: DATE:

Side B

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

6 Sign Elevations - Parking Garage

5.04


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: G1 - OVERHEAD DIRECTIONAL

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1”= 1’-0”

PARK Graphic Layout Location: G1.17

Side A

EXIT Graphic Layout Location: G1.17

PARK Side B

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: G1 - Overhead Directional

JH

CLIENT REQUIRED APPROVAL

PARK Graphic Layout Location: G1.18

EXIT Side A

Graphic Layout Location: G1.18

PARK Graphic Layout Location: G1.19

Side A

PARK Graphic Layout Location: G1.20

REVIEWED BY:

REVISE AND RESUBMIT

PARK Side B

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

EXIT Graphic Layout Location: G1.20

APPROVED

Side B

EXIT Graphic Layout Location: G1.19

EXIT Side A

EXIT

SUBMITTAL: DATE:

PARK Side B

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

6 Sign Elevations - Parking Garage

5.05


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: G2 - WALL DIRECTIONAL

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:4

A Material: 3mm Compbond Background Process: Surface painted Color: As noted Edges: Painted to match face

1’-0”

B Material: Applied matte vinyl Color: As noted Typeface: Gibson - Light Cap Height: 3/4” Cap Height Case: Upper Case Tracking: 25 pt.

A P7

C Material: .063” D/F Tape and silicone

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: G2 - Wall Directional

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE:

TO BUILDING 3 ELEVATORS

REVIEWED BY:

B

V1 APPROVED

2’-0”

REVISE AND RESUBMIT APPROVED AS NOTED

TO BUILDING 2 ELEVATORS

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

TO CAPITAL YARDS STAIRS

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

C

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Front Elevation

Side Elevation

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

6 Sign Elevations - Parking Garage

5.06


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: G2 - WALL DIRECTIONAL

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1:4

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

TO BUILDING 3 ELEVATORS TO BUILDING 2 ELEVATORS

TO BUILDING 3 ELEVATORS

TO BUILDING 2 ELEVATORS

TO BUILDING 3 ELEVATORS

TO BUILDING 2 ELEVATORS

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: G2 - Wall Directional

JH

CLIENT REQUIRED APPROVAL

TO CAPITOL YARDS STAIRS TO CAPITOL YARDS STAIRS

TO BUILDING 2 ELEVATORS

TO CAPITOL YARDS STAIRS

TO CAPITOL YARDS STAIRS

SUBMITTAL: DATE: REVIEWED BY:

TO CAPITOL YARDS STAIRS

APPROVED REVISE AND RESUBMIT

Graphic Layout Location: G2.01

Graphic Layout Location: G2.02

Graphic Layout Location: G2.03

Graphic Layout Location: G2.04

Graphic Layout Location: G2.05

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

TO BUILDING 3 ELEVATORS

TO BUILDING 3 ELEVATORS

TO OFFICE LOBBY ELEVATORS

TO BUILDING 2 ELEVATORS TO OFFICE LOBBY ELEVATORS

TO CAPITOL YARDS STAIRS

TO CAPITOL YARDS STAIRS

TO BUILDING 2 ELEVATORS TO OFFICE LOBBY ELEVATORS

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

TO BUILDING 2 ELEVATORS

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Graphic Layout Location: G2.06

Graphic Layout Location: G2.07

Graphic Layout Location: G2.08

Graphic Layout Location: G2.09

Graphic Layout Location: G2.10

SECTION

SHEET NO.

6 Sign Elevations - Parking Garage

5.07


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: G3 - GARAGE ELEVATOR ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1/2”= 1’-0”

A Material: Applied matte vinyl graphic (heat-formed to wall surface) Size: 4’ Tall Wall Surface: Painted CMU Block and Concrete NOTE: FIELD SURVEYS REQUIRED, BACKGROUND PAINT BY OTHERS

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: G3 - Building Elevator ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

A V2

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

8’-4” VIIF

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Front Elevation

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

6 Sign Elevations - Parking Garage

5.08


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: G3 - GARAGE ELEVATOR ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1”= 1’=0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: G3 - Building Elevator ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

Graphic Layout Locations: G3.04 and G3.05

Graphic Layout Locations: G3.06 and G3.07

Graphic Layout Locations: G3.01, G3.02, G3.03, G3.08, G3.09, and G3.10

Graphic Layout Locations: G3.11 and G3.12

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

6 Sign Elevations - Parking Garage

5.09


6

Buildings 2 and 3 Sign Details


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2Ma - DIRECTIONAL (large)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1 1/2”= 1’- 0”

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: Secured to aluminum frame w/ glue clips 1' 1" 1' 0"

1"

1.5"

1.5"

B Material: .032” raised copy and arrows Finish: As noted Typeface: Gibson - Regular Cap Height: 3/4” Cap Height Case: Upper Case Tracking: 25 pt.

A

C Material: .75” x .75” x .125” fabricated alum. tube frame Background Process: Surface painted Color: As noted Mounting Method: Stud-mount to Wall Surface w/ Jacknuts and structural silicone Wall Surface: Varies - see Notes

P1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2Ma - Directional (large)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

F1

APPROVED AS NOTED

3' 0"

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

Sign Panel

1.5"

3' 3"

B

C P4

Front Elevation

Tube Frame Profile Side Elevation

Tube Frame / Sign Panel

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.01


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2Ma - DIRECTIONAL (large)

Scale: 1 1/2”= 1’- 0”

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

LEASING OFFICE

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2Ma - Directional (large)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE:

FITNESS CENTER BUSINESS CENTER PET SPA RESIDENT LOUNGE

REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Graphic Layout Location: 2Ma-1.01

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.02


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2Mb - DIRECTIONAL (small)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1 1/2”= 1’- 0”

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: Secured to aluminum frame w/ glue clips B Material: .032” raised copy and arrows Finish: As noted Typeface: Gibson - Regular Cap Height: 3/4” Cap Height Case: Upper Case Tracking: 25 pt.

1' 1" 1' 0"

1"

1.5"

1.5"

C Material: .75” x .75” x .125” fabricated alum. tube frame Background Process: Surface painted Color: As noted Mounting Method: Stud-mount to Wall Surface w/ Jacknuts and structural silicone Wall Surface: Varies - see Notes

A

P1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2Mb - Directional (small)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED

APPROVED AS NOTED

1' 6"

Sign Panel B

NOTE

F1

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

1.5"

1' 9"

REVISE AND RESUBMIT

C P4

Front Elevation

Tube Frame Profile Side Elevation

Tube Frame / Sign Panel

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.03


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2Mb - DIRECTIONAL (small)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

LEASING OFFICE HOTEL

BLDG 3 RESIDENT LOUNGE BUSINESS CENTER PET SPA

BRIDGE TO BLDG 3

BRIDGE TO HOTEL

BRIDGE TO BLDG 2 & BLDG 3

BRIDGE TO BLDG 3

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2Mb - Directional (small)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

Graphic Layout Location: 2Mb-1.02

Graphic Layout Location: 2Mb-1.03

Graphic Layout Location: 2Mb-2.01

Graphic Layout Location: 2Mb-2.02

Graphic Layout Location: 2Mb-2.03

Graphic Layout Location: 2Mb-2.04

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

451-457

459-474

551-557

559-574

651-657

659-974

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Graphic Layout Location: 2Mb-4.05a

Graphic Layout Location: 2Mb-4.05b

Graphic Layout Location: 2Mb-5.05a

Graphic Layout Location: 2Mb-5.05b

Graphic Layout Location: 2Mb-6.05a

Graphic Layout Location: 2Mb-6.05b

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.04


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2Mb - DIRECTIONAL (small)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

751-757

759-774

851-857

859-874

951-957

959-974

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2Mb - Directional (small)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

Graphic Layout Location: 2Mb-7.05a

Graphic Layout Location: 2Mb-7.05b

Graphic Layout Location: 2Mb-8.05a

Graphic Layout Location: 2Mb-8.05b

Graphic Layout Location: 2Mb-9.05a

Graphic Layout Location: 2Mb-9.05b

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

1051-1057

1059-1074

1151-1157

1159-1175

BEER GARDEN DEMO KITCHEN MOVIE/MUSIC RM. POOL

CAPITOL VIEW LOUNGE WINE LOUNGE SKY BRIDGE TO BLDG 3

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Graphic Layout Location: 2Mb-10.05a

Graphic Layout Location: 2Mb-10.05b

Graphic Layout Location: 2Mb-11.05a

Graphic Layout Location: 2Mb-11.05b

Graphic Layout Location: 2Mb-14.10

Graphic Layout Location: 2Mb-14.13

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.05


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2P - ELEVATOR DIRECTORY

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1 1/2”= 1’- 0”

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: Secured to aluminum frame w/ glue clips B Material: .032” raised copy and arrows Finish: As noted Typeface: Gibson - Regular Cap Heights: 3/4” and 1/2“ Cap Heights Case: Upper Case Tracking: 25 pt.

1' 1" 1' 0"

1"

C Material: .75” x .75” x .125” fabricated alum. tube frame Background Process: Surface painted Color: As noted Mounting Method: Stud-mount to Wall Surface w/ Jacknuts and structural silicone Wall Surface: Varies - see Notes

1.5"

1.5"

A

P1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2P - Elevator Directory

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

2' 3"

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

Sign Panel B

F1

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

1.5"

2' 6"

NOTE

Tube Frame Profile

C P4

Front Elevation (NOTE: GRAPHIC LAYOUT SHOWN IS FOR ALL 2P LOCATIONS)

Side Elevation

Tube Frame / Sign Panel

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.06


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2N - FLAG ID (double-sided)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:5

A Material: .25” thk. milled aluminum sign panels (2) Background Process: Surface painted - all areas Color: As noted Mounting Method: Secured at 2nd surface to aluminum frame w/ glued angles B Material: .032” raised symbol Finish: As noted Vector Artwork - by Designer Size: Varies

1' .50" 1.5"

C Material: .5” x .5” x .125” fabricted alum. tube frame and 0.25” thk. mounting plate Background Process: Surface painted Color: As noted Mounting Method: Secured to wall w/ appropriate anchor Wall Surface: Varies - see Notes

11.50"

1.5"

C P4 A

P1

B

F1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2N - Flag ID (Double-Sided)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

NOTE: REFERENCE MOUNTING ELEVATIONS AND SIGN LOCATION PLANS FOR BLOCKING LOCATIONS

APPROVED REVISE AND RESUBMIT

11.50"

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

1.5"

1' 3.5"

APPROVED AS NOTED

Front Elevation

Side Elevation

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.07


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2N - FLAG ID (double-sided)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1:5

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2N - Flag ID (Double-Sided)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Graphic Layout Locations: 2N-1.01, 2N-1.02, and 2N-14.03

Graphic Layout Location: 2N-1.04

Graphic Layout Locations: 2N-1.03, 2N-14.09, and 2N-14.10

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.08


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2L - SUITE ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

7.50" EQ.

EQ.

B Material: .032” raised sign copy Finish: As noted Typeface: Gibson - Regular Cap Height: 2” Cap Height Case: Upper Case Tracking: 25 pt. P1

5.5"

A

C Material: .032” raised braille copy Redundant, Grade 2 braille compliant Finish: match sign panel

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2L - Suite ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .063” D/F Tape and silicone B

APPROVED REVISE AND RESUBMIT

F1

APPROVED AS NOTED

NOTE 11.50"

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

2.75"

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

2.0"

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

C

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

D

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Front Elevation

Side Elevation

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.09


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2K - AMENITY ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

1' 1.50" EQ.

EQ.

A

P1

B Material: .032” raised sign copy Finish: As noted Typeface: Gibson - Regular Cap Height: 1” Cap Height Case: Upper Case Tracking: 25 pt.

5"

C Material: .032” raised braille copy Redundant, Grade 2 braille compliant Finish: match sign panel

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2K - Amenity ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .063” D/F Tape and silicone B

APPROVED REVISE AND RESUBMIT

F1

1.625"

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

C

0.375"

10.50"

APPROVED AS NOTED

D

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

Front Elevation

Side Elevation

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.10


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2F - RESTROOM ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

7.50"

1.375"

EQ.

EQ.

5.125"

A

B

P1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

B Material: .032” raised symbol Finish: As noted Vector Artwork - by Designer

DOCUMENT NAME / SUBMITTAL DATE

C Material: .032” raised sign copy Finish: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2F - Restroom ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .032” raised braille copy Redundant, Grade 2 braille compliant Finish: match sign panel

F1

APPROVED REVISE AND RESUBMIT

E Material: .063” D/F Tape and silicone

APPROVED AS NOTED

NOTE 11.50"

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

2.25"

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

3.75"

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

D

0.375"

2"

C F1

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

E

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Front Elevation

Side Elevation Graphic Layout

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.11


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2A - STAIR ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

7.50" EQ.

EQ.

P1

2.50"

A

B

F1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

B Material: .032” raised symbol Finish: As noted Vector Artwork - by Designer

DOCUMENT NAME / SUBMITTAL DATE

C Material: .032” raised sign copy Finish: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2A - Stair ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .032” raised braille copy Redundant, Grade 2 braille compliant Finish: match sign panel

APPROVED REVISE AND RESUBMIT

3.75"

E Material: .063” D/F Tape and silicone

APPROVED AS NOTED

NOTE 11.50"

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

D

0.375"

2"

C F1

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

E

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Front Elevation

Side Elevation

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.12


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2J - ROOM ID (FOH)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B Material: .032” raised sign copy Finish: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

8.50" EQ.

C Material: .032” raised braille copy Redundant, Grade 2 braille compliant Finish: match sign panel

EQ.

A

P1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2J - Room ID (FOH)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .063” D/F Tape and silicone

APPROVED

3"

REVISE AND RESUBMIT APPROVED AS NOTED

B

F1

NOTE

0.375"

1"

6.50"

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

C

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

D

Front Elevation

Side Elevation

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.13


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2H - ROOM ID (BOH)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

8.50" EQ.

C 3D Printed Braille Redundant, Grade 2 braille compliant Color: match sign panel

EQ.

A

P1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2H - Room ID (BOH)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .063” D/F Tape and silicone

APPROVED

3"

REVISE AND RESUBMIT

0.375"

1"

6.50"

IRRIGATION PUMP FILTER ROOM

APPROVED AS NOTED

B P3

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

C D

Front Elevation

Side Elevation

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.14


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2D - EXIT ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

8.00" EQ.

C 3D Printed Braille Redundant, Grade 2 braille compliant Color: match sign panel

EQ.

A

P1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2D - Exit ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .063” D/F Tape and silicone

APPROVED

2.75"

REVISE AND RESUBMIT

0.375"

1"

6.00"

EXIT FIRE ROUTE

APPROVED AS NOTED

B P3

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

C

D

Front Elevation

NOTE

Side Elevation

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.15


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2G - MAX OCCUPANCY

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

8.00" EQ.

C 3D Printed Braille Redundant, Grade 2 braille compliant Color: match sign panel

EQ.

0.375"

1"

6.00"

1"

2.50"

A

P1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2G - Max Occupancy

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .063” D/F Tape and silicone

APPROVED REVISE AND RESUBMIT

MAX OCCUPANCY ###

APPROVED AS NOTED

B P3

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

C D

Front Elevation

NOTE

Side Elevation

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.16


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2E - EVAC/IN CASE OF FIRE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

11.00" 3.00"

C P3

3.00"

IN CASE OF FIRE USE STAIRS

A

P1

B P3

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

B 3D Printed Symbol Color: As noted Vector Artwork - by Designer

DOCUMENT NAME / SUBMITTAL DATE

C 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2E - Evac/In Case of Fire

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .125” UV Non-Glare Acrylic lens Milled profile to match Sign Panel retainer

D

APPROVED REVISE AND RESUBMIT

E Material: 8.5“ x 11” Paper Insert Printed Evacuation Map - by Client 11.25"

E

F Material: .063” D/F Tape and silicone

APPROVED AS NOTED

NOTE

8.00"

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

F

0.25"

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Front Elevation

Side Elevation

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.17


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2C - EGRESS DIRECTION

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 3”= 1’-0”

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes 1' 6.00"

2.5"

STAIR 2-1

1.5"

ROOF ACCESS

3

5.75" 0.375"

2.5" 1.5" 1.5"

1' 8"

2.75"

LEVEL

DOWN TO FLOOR 1 FOR EXIT DISCHARGE LEVELS P1-12 Front Elevation

A

B 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 1 1/2” Cap Height Case: Upper Case Tracking: 25 pt.

P1

B P3

C 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 1” Cap Height Case: Upper Case Tracking: 25 pt.

C P3

D P3

D 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 1 1/2” Cap Height Case: Upper Case Tracking: 25 pt.

E P3

E 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 5” Cap Height Case: Upper Case Tracking: 25 pt.

F P3 G P3 C P3

H

Side Elevation

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 2C - Egress Direction

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

F 3D Printed Braille Redundant, Grade 2 braille compliant Color: match sign panel

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

G 3D Printed Arrow Color: As noted Vector Artwork - by Designer

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

H Material: .063” D/F Tape and silicone

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

6.18


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Ma - DIRECTIONAL (large)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1 1/2”= 1’- 0”

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: Match MFMN Midnight (Carvart.com) Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B Material: .032” raised copy and arrows Finish: Coppertone Typeface: Gibson - Regular Cap Height: 3/4” Cap Height Case: Upper Case Tracking: 25 pt.

1' 0"

A P2

C Material: .085“ W x .032” raised border Finish: As noted D Material: .063” D/F Tape and silicone

B

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Ma - Directional (large)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

F1

APPROVED REVISE AND RESUBMIT

C F1

3' 0"

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

D

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

Front Elevation

Side Elevation

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.19


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Ma - DIRECTIONAL (large)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

PET SPA FITNESS CENTER LEASING OFFICE

PET SPA FITNESS CENTER LEASING OFFICE

126-133

109-117 RESIDENT LOUNGE BUSINESS CENTER

RESIDENT LOUNGE BUSINESS CENTER

PET SPA FITNESS CENTER LEASING OFFICE

126-133 PET SPA FITNESS CENTER LEASING OFFICE

BRIDGE TO BLDG 2 & HOTEL

201-225 ELEVATORS

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Ma - Directional (large)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

201-239 ELEVATORS RESIDENT LOUNGE BUSINESS CENTER

234-245 BRIDGE TO BLDG 2 & HOTEL

APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

241-245 226-233 ELEVATORS

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Graphic Layout Location: 3Ma-1.08

Graphic Layout Location: 3Ma-1.09

Graphic Layout Location: 3Ma-1.10

Graphic Layout Location: 3Ma-1.11

Graphic Layout Location: 3Ma-2.06

Graphic Layout Location: 3Ma-2.07

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.20


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Ma - DIRECTIONAL (large)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

201-224 234-245 ELEVATORS BRIDGE TO BLDG 2 & HOTEL

218-245 ELEVATORS

301-325 ELEVATORS

318-345 ELEVATORS

401-425 ELEVATORS

418-445 ELEVATORS

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Ma - Directional (large)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

201-210

334-345

301-310

434-445

401-410

APPROVED REVISE AND RESUBMIT

225-233 212-217

326-333 ELEVATORS

312-317

426-433 ELEVATORS

412-417

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Graphic Layout Location: 3Ma-2.09

Graphic Layout Location: 3Ma-2.10

Graphic Layout Location: 3Ma-3.01

Graphic Layout Location: 3Ma-3.04

Graphic Layout Location: 3Ma-4.01

Graphic Layout Location: 3Ma-4.04

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.21


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Ma - DIRECTIONAL (large)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

501-525 ELEVATORS

518-545 ELEVATORS

601-625 ELEVATORS

618-645 ELEVATORS

701-725 ELEVATORS

718-745 ELEVATORS

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Ma - Directional (large)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

534-545

501-510

634-645

601-610

734-745

701-710

APPROVED REVISE AND RESUBMIT

526-533 ELEVATORS

512-517

626-633 ELEVATORS

612-617

726-733 ELEVATORS

712-717

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Graphic Layout Location: 3Ma-5.01

Graphic Layout Location: 3Ma-5.04

Graphic Layout Location: 3Ma-6.01

Graphic Layout Location: 3Ma-6.04

Graphic Layout Location: 3Ma-7.01

Graphic Layout Location: 3Ma-7.04

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.22


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Ma - DIRECTIONAL (large)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

801-825 ELEVATORS

818-845 ELEVATORS

901-925 ELEVATORS

918-945 ELEVATORS

1001-1025 ELEVATORS

1018-1045 ELEVATORS

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Ma - Directional (large)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

834-845

801-810

934-945

901-910

1034-1045

1001-1010

APPROVED REVISE AND RESUBMIT

826-833 ELEVATORS

812-817

926-933 ELEVATORS

912-917

1026-1033 ELEVATORS

1012-1017

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Graphic Layout Location: 3Ma-8.01

Graphic Layout Location: 3Ma-8.04

Graphic Layout Location: 3Ma-9.01

Graphic Layout Location: 3Ma-9.04

Graphic Layout Location: 3Ma-10.01

Graphic Layout Location: 3Ma-10.04

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.23


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Ma - DIRECTIONAL (large)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

1101-1125 ELEVATORS

1118-1145 ELEVATORS

1201-1225 ELEVATORS

1218-1245 ELEVATORS

1301-1325 ELEVATORS

1318-1345 ELEVATORS

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Ma - Directional (large)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

1134-1145

1101-1110

1234-1245

1201-1210

1334-1345

1301-1310

APPROVED REVISE AND RESUBMIT

1126-1133 ELEVATORS

1112-1117

1226-1233 ELEVATORS

1212-1217

1326-1333 ELEVATORS

1312-1317

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Graphic Layout Location: 3Ma-11.01

Graphic Layout Location: 3Ma-11.04

Graphic Layout Location: 3Ma-12.01

Graphic Layout Location: 3Ma-12.04

Graphic Layout Location: 3Ma-13.01

Graphic Layout Location: 3Ma-13.04

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.24


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Mb - DIRECTIONAL (small)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1 1/2”= 1’- 0”

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: Match MFMN Midnight (Carvart.com) Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B Material: .032” raised copy and arrows Finish: Coppertone Typeface: Gibson - Regular Cap Height: 3/4” Cap Height Case: Upper Case Tracking: 25 pt.

1' 0"

C Material: .085“ W x .032” raised border Finish: As noted D Material: .063” D/F Tape and silicone

A P2

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Mb - Directional (small)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

1' 6"

B

F1

APPROVED AS NOTED

C F1

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

D

Front Elevation

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Side Elevation

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.25


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Mb - DIRECTIONAL (small)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

BLDG 2 FITNESS CENTER LEASING OFFICE HOTEL

RESIDENT LOUNGE BUSINESS CENTER

109-117

109-117

109

111-117

126-133 RESIDENT LOUNGE BUSINESS CENTER PET SPA FITNESS CENTER LEASING OFFICE

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Mb - Directional (small)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

Graphic Layout Location: 3Mb-1.04

Graphic Layout Location: 3Mb-1.07

Graphic Layout Location: 3Mb-1.12

Graphic Layout Location: 3Mb-1.13

Graphic Layout Location: 3Mb-1.15

Graphic Layout Location: 3Mb-1.17

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

BRIDGE TO BLDG 2 & HOTEL

225-233

201-224 234-245 ELEVATORS BRIDGE TO BLDG 2 & HOTEL

325-333

319-345

301-324 334-345

301-318

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Graphic Layout Location: 3Mb-2.05

Graphic Layout Location: 3Mb-2.08a

Graphic Layout Location: 3Mb-2.08b

Graphic Layout Location: 3Mb-3.02a

Graphic Layout Location: 3Mb-3.02b

Graphic Layout Location: 3Mb-3.03

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.26


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Mb - DIRECTIONAL (small)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

426-433

419-445

401-425 434-445

526-533

501-518

501-525 534-545

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Mb - Directional (small)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE:

401-418

REVIEWED BY:

519-545

APPROVED REVISE AND RESUBMIT

Graphic Layout Location: 3Mb-4.02a

Graphic Layout Location: 3Mb-4.02b

Graphic Layout Location: 3Mb-4.03

Graphic Layout Location: 3Mb-5.02a

Graphic Layout Location: 3Mb-5.02b

Graphic Layout Location: 3Mb-5.03

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

626-633

601-625 634-645

619-645

726-733

701-725 734-745

601-618

719-745

701-718

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Graphic Layout Location: 3Mb-6.02a

Graphic Layout Location: 3Mb-6.02b

Graphic Layout Location: 3Mb-6.03

Graphic Layout Location: 3Mb-7.02a

Graphic Layout Location: 3Mb-7.02b

Graphic Layout Location: 3Mb-7.03

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.27


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Mb - DIRECTIONAL (small)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

826-833

819-845

801-825 834-845

926-933

919-945

901-925 934-945

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Mb - Directional (small)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE:

801-818

REVIEWED BY:

901-918

APPROVED REVISE AND RESUBMIT

Graphic Layout Location: 3Mb-8.02a

Graphic Layout Location: 3Mb-8.02b

Graphic Layout Location: 3Mb-8.03

Graphic Layout Location: 3Mb-9.02a

Graphic Layout Location: 3Mb-9.02b

Graphic Layout Location: 3Mb-9.03

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

1026-1033

1001-1025 1034-1045

1019-1045

1126-1133

1119-1145

1101-1125 1134-1145

1001-1018

1101-1118

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Graphic Layout Location: 3Mb-10.02a

Graphic Layout Location: 3Mb-10.02b

Graphic Layout Location: 3Mb-10.03

Graphic Layout Location: 3Mb-11.02a

Graphic Layout Location: 3Mb-11.02b

Graphic Layout Location: 3Mb-11.03

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.28


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3Mb - DIRECTIONAL (small)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1 1/2”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

1226-1233

1201-1225 1234-1245

1219-1245

1326-1333

1301-1325 1334-1345

1319-1345

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3Mb - Directional (small)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE:

1201-1218

1301-1318

REVIEWED BY: APPROVED REVISE AND RESUBMIT

Graphic Layout Location: 3Mb-12.02a

Graphic Layout Location: 3Mb-12.02b

Graphic Layout Location: 3Mb-12.03

Graphic Layout Location: 3Mb-13.02a

Graphic Layout Location: 3Mb-13.02b

Graphic Layout Location: 3Mb-13.03

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

BEER GARDEN DEMO KITCHEN

MOVIE/MUSIC RM. POOL SKY BRIDGE TO BLDG 2

BEER GARDEN DEMO KITCHEN SKY BRIDGE TO BLDG 2

CAPITOL VIEW LOUNGE WINE LOUNGE

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

MOVIE/MUSIC RM.

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Graphic Layout Location: 3Mb-14.01

Graphic Layout Location: 3Mb-14.02

Graphic Layout Location: 3Mb-14.05

Graphic Layout Location: 3Mb-14.09

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.29


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3P - ELEVATOR DIRECTORY

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1 1/2”= 1’- 0”

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: Match MFMN Midnight (Carvart.com) Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B Material: .032” raised copy and arrows Finish: Coppertone Typeface: Gibson - Regular Cap Heights: 3/4” and 1/2” Cap Heights Case: Upper Case Tracking: 25 pt.

1' 0"

C Material: .085“ W x .032” raised border Finish: As noted D Material: .063” D/F Tape and silicone

A P2

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3P - Elevator Directory

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

NOTE F1

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

2' 3"

B

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

C F1 D

Front Elevation (NOTE: GRAPHIC LAYOUT SHOWN IS FOR ALL 3P LOCATIONS)

Side Elevation

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.30


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3N - FLAG ID (double-sided)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1 :4

A Material: .25” thk. milled aluminum sign panels (2) Background Process: Surface painted Color: Match MFMN Midnight (Carvart.com) Mounting Method: Secured at 2nd surface to aluminum frame w/ glued angles

1.5"

B Material: .032” raised symbol Finish: Coppertone Vector Artwork - by Designer Size: Varies

11.50"

C Material: .25“ W x .032” raised border Finish: As noted

D P4

D Material: 1” square. alum. pipe supports and 0.25” thk. mounting plate Background Process: Surface painted - all areas Color: As noted Mounting Method: Secured to wall w/ appropriate anchor Wall Surface: Varies - see Notes

A P2 B

F1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3N - Flag ID (Double-Sided)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

NOTE: REFERENCE MOUNTING ELEVATIONS AND SIGN LOCATION PLANS FOR BLOCKING LOCATIONS

APPROVED AS NOTED

11.50"

C F1

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Front Elevation

Side Elevation

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.31


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 2N - FLAG ID (double-sided)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1:4

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3N - Flag ID (Double-Sided)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT

Graphic Layout Locations: 3N-1.05, 3N-1.09, 3N-14.01, and 3N-14.02

Graphic Layout Locations: 3N-1.07 and 3N-1.08

Graphic Layout Location: 3N-1.10

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Graphic Layout Location: 3N-14.08

Graphic Layout Location: 3N-14.07

Graphic Layout Locations: 3N-1.06, 3N-14.04, 3N-14.05, and 3N-14.06

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.32


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3L - SUITE ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B Material: .032” raised sign copy Finish: As noted Typeface: Gibson - Regular Cap Height: 2” Cap Height Case: Upper Case Tracking: 25 pt.

11" EQ.

EQ. D

F1

3.50"

A P2

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3L - Suite ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .085“ W x .032” raised border Finish: As noted

APPROVED REVISE AND RESUBMIT

E Material: .063” D/F Tape and silicone F1

5"

B

C Material: .032” raised braille copy Redundant, Grade 2 braille compliant Finish: match sign panel

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

APPROVED AS NOTED

NOTE 0.375"

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

C

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

E

Front Elevation

Side Elevation

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.33


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3K - AMENITY ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

1' 1.50" EQ.

EQ. D

F1

A P2

B Material: .032” raised sign copy Finish: As noted Typeface: Gibson - Regular Cap Height: 1” Cap Height Case: Upper Case Tracking: 25 pt.

5"

C Material: .032” raised braille copy Redundant, Grade 2 braille compliant Finish: match sign panel

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3K - Amenity ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .085“ W x .032” raised border Finish: As noted B

F1

APPROVED REVISE AND RESUBMIT

E Material: .063” D/F Tape and silicone

1.625"

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

C

0.375"

10.50"

APPROVED AS NOTED

E

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

Front Elevation

Side Elevation

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.34


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3F - RESTROOM ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

7.50" EQ.

EQ.

1.375"

E

F1

5.125"

A P2

B

DOCUMENT NAME / SUBMITTAL DATE

C Material: .032” raised sign copy Finish: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3F - Restroom ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .032” raised braille copy Redundant, Grade 2 braille compliant Finish: match sign panel

F1

APPROVED REVISE AND RESUBMIT

E Material: .085“ W x .032” raised border Finish: As noted

11.50"

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

2.25"

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

3.75"

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

C F1

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

D

0.375"

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

B Material: .032” raised symbol Finish: As noted Vector Artwork - by Designer

F Material: .063” D/F Tape and silicone

2"

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

F

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Front Elevation

Side Elevation Graphic Layout

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.35


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3A - STAIR ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

7.50" EQ.

EQ.

2.50"

E

F1

A P2

B

F1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

B Material: .032” raised symbol Finish: As noted Vector Artwork - by Designer

DOCUMENT NAME / SUBMITTAL DATE

C Material: .032” raised sign copy Finish: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3A - Stair ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .032” raised braille copy Redundant, Grade 2 braille compliant Finish: match sign panel

APPROVED REVISE AND RESUBMIT

3.75"

E Material: .085“ W x .032” raised border Finish: As noted

11.50"

F Material: .063” D/F Tape and silicone

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

D

0.375"

2"

C F1

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

F

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Front Elevation

Side Elevation

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.36


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3J - ROOM ID (FOH)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. milled aluminum sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B Material: .032” raised sign copy Finish: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

11" EQ.

EQ. D

F1

2.31"

A P2

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3J - Room ID (FOH)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .085“ W x .032” raised border Finish: As noted

APPROVED REVISE AND RESUBMIT

E Material: .063” D/F Tape and silicone F1

5"

B

C Material: .032” raised braille copy Redundant, Grade 2 braille compliant Finish: match sign panel

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

APPROVED AS NOTED

1"

NOTE

0.375"

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

C

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

E

Front Elevation

Side Elevation

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.37


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3H - ROOM ID (BOH)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

11" EQ.

EQ. D P2

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3H - Room ID (BOH)

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .063” D/F Tape and silicone

APPROVED

2.31"

A P2

C 3D Printed Braille Redundant, Grade 2 braille compliant Color: match sign panel

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

0.375"

1"

5"

IRRIGATION PUMP FILTER ROOM

REVISE AND RESUBMIT

B P3

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

C

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

E

Front Elevation

APPROVED AS NOTED

Side Elevation

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.38


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3D - EXIT ID

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

9.5" EQ.

EQ.

1.75"

D P2

0.375"

1"

4"

EXIT FIRE ROUTE

A P2

C 3D Printed Braille Redundant, Grade 2 braille compliant Color: match sign panel

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3D - Exit ID

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .063” D/F Tape and silicone

APPROVED REVISE AND RESUBMIT

B P3

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

C E

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

Front Elevation

Side Elevation

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.39


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3G - MAX OCCUPANCY

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes B 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

11" EQ.

EQ. D P2

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3G - Max Occupancy

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .063” D/F Tape and silicone

APPROVED

2.31"

A P2

C 3D Printed Braille Redundant, Grade 2 braille compliant Color: match sign panel

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

0.375"

1"

5"

MAX OCCUPANCY ###

REVISE AND RESUBMIT

B P3

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

C

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

E

Front Elevation

APPROVED AS NOTED

Side Elevation

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.40


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3E - EVAC/IN CASE OF FIRE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 1:2

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

11.00" 3.00"

C P3

3.00"

IN CASE OF FIRE USE STAIRS

A P2

B P3

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

B 3D Printed Symbol Color: As noted Vector Artwork - by Designer

DOCUMENT NAME / SUBMITTAL DATE

C 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 5/8” Cap Height Case: Upper Case Tracking: 25 pt.

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3E - Evac/In Case of Fire

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

D Material: .125” UV Non-Glare Acrylic lens Milled profile to match Sign Panel retainer

D

APPROVED REVISE AND RESUBMIT

E Material: 8.5“ x 11” Paper Insert Printed Evacuation Map - by Client 11.25"

E

F Material: .063” D/F Tape and silicone

APPROVED AS NOTED

NOTE

8.00"

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

F

0.25"

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Front Elevation

Side Elevation

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.41


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SIGN TYPE: 3C - EGRESS DIRECTION

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Scale: 3”= 1’-0”

A Material: .25” thk. acrylic sign panel Background Process: Surface painted Color: As noted Mounting Method: D/F tape mount to Wall Surface Wall Surface: Varies - see Notes

1' 6.00"

B P3

C P3

LEVEL

D P3

DOWN TO FLOOR 1 FOR EXIT DISCHARGE LEVELS P1-12 Front Elevation

A P2

ROOF ACCESS

3

5.75" 0.375"

2.5" 1.5" 1.5"

1' 8"

2.75"

1.5"

2.5"

STAIR 2-1

B 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 1 1/2” Cap Height Case: Upper Case Tracking: 25 pt.

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Sign Type: 3C - Egress Directional

JH

CLIENT REQUIRED APPROVAL C 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 1” Cap Height Case: Upper Case Tracking: 25 pt. D 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 1 1/2” Cap Height Case: Upper Case Tracking: 25 pt.

E P3

E 3D Printed Copy Color: As noted Typeface: Gibson - Regular Cap Height: 5” Cap Height Case: Upper Case Tracking: 25 pt.

F P3 G P3 C P3

F 3D Printed Braille Redundant, Grade 2 braille compliant Color: match sign panel

H

G 3D Printed Arrow Color: As noted Vector Artwrk - by Designer

Side Elevation

H Material: .063” D/F Tape and silicone

SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

6.42


7

Buildings 2 and 3 Select Mounting Elevations


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SELECT MOUNTING ELEVATIONS: BUILDING 2

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1/4”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

ALIGN WITH DOOR EDGE OF 2K SIGNS TYP.

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Select Mounting Elevations

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE:

MAIL ROOM

REVIEWED BY:

SPACE FROM FRAME PER ADA 60" OC TYP.

ALIGN TOP OF 2P SIGNS WITH TOP OF ELEVATOR FRAMING

DOCUMENT NAME / SUBMITTAL DATE

APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

Sign Locations 2K-1.11 and 2N-1.04

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

SPACE FROM FRAME PER ADA FITNESS CENTER

STAFF ONLY

Sign Locations 2J-1.24 and 2K-1.12

60" OC TYP.

60" OC TYP.

SPACE FROM FRAME PER ADA

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

7.01


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SELECT MOUNTING ELEVATIONS: BUILDING 2

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1/4”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

ALIGN TOP OF 2P SIGNS WITH TOP OF ELEVATOR FRAMING

DOCUMENT NAME / SUBMITTAL DATE

6" FROM CORNER

LEASING OFFICE

ALL 2Ma SIGNS 60" OC TYP.

FITNESS CENTER BUSINESS CENTER PET SPA RESIDENT LOUNGE

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Select Mounting Elevations

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

Sign Locations 2Ma-1.01 and 2N-1.02

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

Sign Locations 2P-1.01 and 2E-1.5

B P3

60" OC TYP.

ALIGN TOP OF 2P SIGNS WITH TOP OF ELEVATOR DOORS

6" TYP. FOR SIGN TYPE 2P

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

4 Sign Elevations - Building 2

7.02


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SELECT MOUNTING ELEVATIONS: BUILDING 3

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1/4”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

ALIGN TOP OF 3P SIGNS WITH TOP OF ELEVATOR FRAMING

EQ.

EQ.

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Select Mounting Elevations

JH

CLIENT REQUIRED APPROVAL

SPACE FROM FRAME PER ADA MAIL ROOM

60" OC TYP.

ALIGN TOP OF 3P SIGNS WITH TOP OF ELEVATOR DOORS

DOCUMENT NAME / SUBMITTAL DATE

SUBMITTAL: DATE: REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

Sign Locations 3P-1.04, 3N-1.05, 3N-1.08, and 3K-1.2

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

6" FROM CORNER

B P3

HOUSEKEEPING

PET SPA

60" OC TYP.

60" OC TYP.

109-117

60" OC TYP.

ALL 3Ma SIGNS 60" OC TYP.

PET SPA FITNESS CENTER LEASING OFFICE

Sign Locations 3Ma-1.10, 3E-1.3, 3J-1.11, and 3K-1.3

SPACE FROM FRAME PER ADA

SPACE FROM FRAME PER ADA

126-133

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

7.03


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SELECT MOUNTING ELEVATIONS: BUILDING 3

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

Scale: 1/4”= 1’- 0”

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Select Mounting Elevations

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE:

B P3

EQ.

REVIEWED BY:

60" OC TYP.

ALIGN TOP OF 3P SIGNS WITH TOP OF ELEVATOR DOORS

DOCUMENT NAME / SUBMITTAL DATE

EQ.

APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

Sign Locations 3P-1.03 and 3E-1.2

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

6" FROM FRAME

SPACE FROM FRAME PER ADA

60" OC TYP.

ALL 3Mb SIGNS 60" OC TYP.

109-117

STORAGE

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Sign Locations 3Mb-1.12 and 3J-1.7

SECTION

SHEET NO.

5 Sign Elevations - Building 3

7.04


7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com

SELECT MOUNTING ELEVATIONS: BUILDING 3

Scale: 1/4”= 1’- 0”

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

6" FROM FRAME

Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Select Mounting Elevations

JH

CLIENT REQUIRED APPROVAL 126-133 PET SPA FITNESS CENTER LEASING OFFICE

SUBMITTAL: DATE:

RESIDENT LOUNGE BUSINESS CENTER

ALL 3Ma SIGNS 60" OC TYP.

REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED

Sign Location 3Ma-1.11

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

60" OC TYP.

B P3

Sign Locations 3E-1.12

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

5 Sign Elevations - Building 3

7.05


8

Exterior Sign Locations and Messages


7440 Fort Smallwood Rd. Baltimore, MD 21226 C-1

main 410.255.6400 | 800.854.0568 gablecompany.com A

A

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. SIM 3 L501

__________

1.0%

1

44' - 8"

17 A306

2.7%

44' - 3"

46' - 7"

1.6%

A306

% 1.4

2

10' - 3"

21' - 8"

E1

N PERIMETER DRIVE REFER TO SHEETS L201 & L202 FOR ENLARGED PLANS

15' - 4"

C-6

1 3' - 6"

6

15' - 0" 6

2' - 8"

6

6

C-5

2

1

2

RETRACTABLE GATE BOD: FANCY FENCE

11

PEPCO VAULTS

12

CAPITOL YARDS ACCESS

13

SECURE ACCESS GATE

14

CONC MECHANICAL PAD

15

WEST BIORETENTION YARD

6

22

SITE SIGNAGE

RFI 419

3

3

A306

OD

LL3

1/8" = 1'-0"

LL3

A307 7 2 L502

A307

__________

3

KTA Group LL3 12950 Worldgate Dr, StA308 100 A307 Herndon, VA 20170 A308 703.713.0300 A315 www.ktagroup.com 4

1/8" = 1'-0"

E2

LL3 MECHANICAL ENG - HOTEL

1. REFER TO SHEET L100 FOR ADDITIONAL NOTES, ABBREVIATIONS & SYMBOLS.

EDG2 LL3 Engineering Design Group CP-1 10411 Motor City Dr, St 550 Bethesda,CMD 20817 202.466.2232 www.edg2.com

FD

C

6

4

7. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL PRECAST/CAST STONE, DIMENSIONAL STONE, AND ALL METAL/GLASS FABRICATIONS B3 ARRIVAL AREA - LIGHTING & FURNITURE PLAN SCALE:

8. ALL CONCRETE WALLS AND CURBS SHALL BE FINISHED WITH ELASTOMERIC PAINT. SAMPLES OF SPECIFIED COLOR WILL BE PROVIDED TO R2L FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION 9. BIORETENTION AND PERMEABLE PAVING UNDERDRAINS TO BE 4 OR 6 INCH RIGID SCHEDULE 40 PVC PIPE, WITH 3/8 INCH PERFORATIONS AT 6 INCHES ON CENTER. 10. SEE CIVIL PLANS FOR DETAILS OF OFF-STRUCTURE BIORETENTION AREAS. 11. SEE CIVIL PLANS FOR EXTENT OF CONCRETE CURB AT NEW JERSEY AVENUE. 12. ALL GRANITE CURBS TO HAVE 1/4" CHAMFERED CORNERS.

Power Design, Inc 11600 Ninth Street North Petersburg, FL 33716 727.210.0492 www.powerdesigninc.us

GeoConcepts Engineering, Inc 19955 Highland Vista Dr, St 170 Ashburn, VA 20147 703.726.8030 www.geoconcepts-eng.com

5

INTERIOR DESIGN - HOTEL

DLR Group 520 Nicollet Mall, St 200 Minneapolis, MN 55402 612.977.3500 www.dlrgroup.com LIGHTING DESIGN - RESI

Power Design, Inc 11600 Ninth Street North Petersburg, FL 33716 727.210.0492 www.powerdesigninc.us

A309

APPROVED

6

122 .0°

11 1/4" TYP. C-3

1'-3 1/8" 9 SIM L501

__________

17

C

3 L606

APPROVED AS NOTED

C-5

9 SIM L501 C-5

146.0°

4 L600

C-5

2' - 6"

__________

OD

C

1.6°

14' - 0" 3 L600

P-1

__________

37'-6" GR-1

CP-1

4

7 L502

4

__________

E FD

37'-6"

WP-1

P-1

WP-1

OD

SIM 1 L501

__________

C-5

37'-2"

C C

WP-1

CP-1

19 19 WP-1 DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION REQUIRE 6 AND C-5 RFI 346 37'-2"5 SIM TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND L503 WP-1 PERMITTING PRIOR TO FABRICATION. __________

Q

6

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. 3 4 5 WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL 1 B3 ARRIVAL AREA - PAVING PLAN SCALE: 1/8" = 1'-0"TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, COVERING, CERAMIC VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

1

13' - 5" OD

SIM 2 L501

__________

° 64.2

__________

NOTE

36'-8"

__________

2'-6"

REVISE AND RESUBMIT

FD

E

19

C-2

C-5

WP-1 WP-1

OD

RP

C-5

34'-0"

1

0' - 9"

PE

8"

0'

ER A V -5 3P C C- R TO A UL IC ND

6 6

2

JH

6' - 3"

C

LK1

GEOTECHNICAL ENG ENVIRONMENTAL ENG

WPF Engineering, LLC 1671 House Street NE Belmont, MI 49306 616.340.9627 www.wpf-engineering.com

A315

D REVIEWED BY:

ELECTRICAL ENG - ALL

LIGHTING DESIGN - HOTEL

A303

C

MECHANICAL ENG - RESI

2

3

LK1

PLUMBING ENG - ALL

6. REFER TO ARCHITECURAL & STRUCTURAL DRAWINGS FOR MORE INFORMATION ON CONCRETE SLABS AND PLANTER WALL DETAILS/DIMENSIONS.

4

16.2° C-5

KTA Group 12950 Worldgate Dr, St 100 Herndon, VA 20170 703.713.0300 www.ktagroup.com

LL3

48.8 °

5'-1 7/8" SUBMITTAL: DATE:

3

Wiles Mensch Corporation 6 11860 Sunrise Valley Dr, St 200 Reston, VA 20191 703.390.7600 www.wilesmensch.com

4. REFER TO L5 SERIES SHEETS FOR LANDSCAPE AND HARDSCAPE DETAILS.

2

N PERIMETER DRIVE - WEST CORNER - PAVING & LIGHTING PLAN SCALE:

10

H2O RATED ACCESS HATCH, FLUSH WITH FINISH GRADE

5. CROSS & DRAINAGE SLOPES AT PAVER AND DECKING PEDESTRIAN SURFACES SHALL NOT EXCEED 2% IN ANY DIRECTION.

1

A314

WINDOW WELLS

LK1

CIVIL ENGINEERING

3. REFER TO L2 SERIES DRAWINGS FOR ENLARGED PLANTING, PAVING, LIGHTING AND FURNITURE PLANS. C-3

SOUTHWEST PERIMETER YARD REFER TO SHEET L203 FOR ENLARGED PLANS

GF UNIT TERRACE

9

21

2. REFER TO SHEET L100 FOR MATERIAL AND LIGHTING SCHEDULES.

C-5

OD

4' - 0"

8

GENERAL NOTES

11' - 1"

12' - 4"

2.7 %

11' - 6"

2' - 7"

3' - 4"

A

2' - 7"

A315

E

CENTRAL WATER FEATURE

TYP.

° 2.0 13

A300

1.1%

1

7

6

C

13' - 10"

D

1.8%

17

2.0%

A316A

11 1/4"

CLIENT REQUIRED APPROVAL

STRUCTURAL ENGINEERING

Smislova, Kehnemui & Assoc 12435 Park Potomac Ave, St 300 Potomac, MD 20854 301.881.1441 A308 1 www.skaengineers.com A305

6

9'-7"

4'-1 1/8"

TRENCH DRAIN

GRANITE CURB AND BRICK GUTTER 1 PER SEE A304 CIVIL 1 DDOT A307 STANDARDS, DWGS FOR DETAILS

OD

Exterior

C-5

C-5

16' - 11"

6

1.2%

1.5%

20

3 L605

__________

8"

MECH SHAFTS

19

GRAVEL SPLASH PAD, SEE CIVIL DWGS FOR DETAIL IN OFF-STRUCTURE BIORETENTION PLANTERS

LK1

0' -

STEPPED SEATING AND BENCHES

5

BOLLARD POWER STATION

3222 N ST NW SUITE 500 Washington, DC 20007 t 202.600.7230 f 202.600.7280 info@r2l-architects.com

41.0°

90.0°

115.0°

4

4' - 6" C-1

18

6

4' - 0" 1' - 2"

MOVEABLE PLANTERS

AREA DRAINS PER CIVIL

54.8 °

5' - 1"

DRAWN BY

RFI 338

8' - 5"

3

MANHOLE COVER, SEE CIVIL

17

9'-11 1/8"

CAPITOL BIKESHARE STATION

Q

19

C-5

YP "T 1/4

2.2%

AC HOTEL SIGNAGE

2

LK1 16

SHEET NAME

OD

C-5

04.21.2021

FE

11

31' - 7"

1

C

LK1

PE ER

C-5

" -6

1.8 %

2.9%

C

ARCHITECTURAL DESIGN LANDSCAPE DESIGN INTERIOR DESIGN - RESI

P ER

Design-Build Package - POST FINAL REVISED

REF

FE

KEYNOTES

V PA

0'

41' - 8"

DW

LK1

C-3

RFI 377

C

11'-0 1/2" 0' - 10"

8"

DOCUMENT NAME / SUBMITTAL DATE

R LA ICU ND

C-5 TO

1.3°

56.8 °

0' -

LK1

LK1

C

C-3

6 A813

__________

OD

7' - 6"

LK1

8'-4 3/4"

C-5

35'-7"

LK1

C

C-5

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

A306

3

6 A813

C-5

6

LK1

LK1 __________

.3° 77

° 4.0 10

LK1

E10-2.03

° 90.0

1' - 5"

3

7' - 0"

A315

N PERIMETER DRIVE REFER TO SHEETS L201 & L202 FOR ENLARGED PLANS

0' - 11"

4

6

2 SIM L502

__________

18.0°

5'-1 3/8"

OD

8' - 2"

LK1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 B 9'-3 5/8"

OD

B

A308

N PERIMETER DRIVE REFER TO SHEETS L201 & L202 FOR ENLARGED PLANS

SECTION

SHEET NO.

8 Locations and Messages

8.01

FD


A323

A326 N PERIMETER DRIVE REFER TO SHEETS 2 FOR L201 & L202 ENLARGED PLANS

A323

1

E10-2.02 C

OD

3

A309

2

34'-10" 2 L614

REF

C

OD

CP-1

BB G

LK1

A315

LK1

LK1

WP-1

E3.08 LK1

1

A311

FE

A312 A312

10

FD

LK1

LK1

LL3

WP-1 WP-1

LL3

WP-1

2

LL3

A310

LL3

CP-1

LK1

2

FD

RFI 384 R1 CP-1 LK1

FF

LK1

WP-1 2 L506

7

LK1

A310

G

A315

F RE

FE

1

A-1

FD

LL3

4 L504

FD

5 L502

LK1

9

__________

WP-1

CAPITAL YARDS CONNECTION REFER TO SHEETS L207& L208 FOR ENLARGED PLANS

6

CL-1

WC-3

WC-3

FD

LK1

30

8

31

2

A310

C-2 ALIGNED WITH BUILDING FACE

34'-0"

OD C

RETRACTABLE GATE BOD: FANCY FENCE

WC-3

36

11

PEPCO VAULTS

12

CAPITOL YARDS ACCESS

13

SECURE ACCESS GATE

14

CONC MECHANICAL PAD

15

WEST BIORETENTION YARD

F

7

C-3 A315

8 A315

LK1

LK1

CP-1

6

6

19

703.713.0300 www.ktagroup.com

37'-2"

C

2 L607

1

LL3 LL3

6 SIM L501

__________

__________

4

4

30

34'-10"

CENTRAL COURTYARD - LIGHTING & FURNITURE PLAN SCALE:

FD

CP-1

C-5

6

FD

C-2 ALIGNED WITH PLANTER FACE

6

C-5

CP-1

ALIGN C-3 PAVER WITH BUILDING FACE

C-5

C-3

CL-1 4 SIM L502

__________

6

C3

CL-1 5 L504

C

__________

Petersburg, FL 33716 727.210.0492

FD

3 L607

__________

www.powerdesigninc.us WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL LIGHTING DESIGN - HOTEL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, WPF Engineering, LLC J VINYL BACKPLATE REQUIRED PAINTED TO MATCH SIGN FACE. WHEN 1671 HouseIS Street NE Belmont, MI 49306 MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL 616.340.9627 34'-10" BACKPLATEwww.wpf-engineering.com IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO SIM 2 FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS L501 AND APPROPRIATE MOUNTING METHODS.

WP-1

CL-1

HH

34

LL3

A310

LL3 FD

LL3

1/8" = 1'-0"

31

CAPITAL YARDS CONNECTION REFER TO SHEETS L207 & L208 FOR ENLARGED PLANS

CP-1

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR CP-1 COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

B3 SOUTH PATIO & PATH REFER TO SHEETS L205 FOR ENLARGED PLANS

SECTION

30

8

33

8 Locations and Messages 2 CENTRAL COURTYARD - PAVING PLAN SCALE:

ASI 017

JJ

C-2

CP-1

CP-1

6

1/8" = 1'-0"

36'-0"

35'-4"

C-5

__________

C

KK

C-2

CP-1

5

GeoConcepts Engineering, Inc 19955 Highland Vista Dr, St 170 Ashburn, VA 20147 703.726.8030 www.geoconcepts-eng.com

SIM 2 L501

FD

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER 19 TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

OD

OD

8

WP-1

2 L504

__________

FD

APPROVED AS NOTED GEOTECHNICAL ENG ENVIRONMENTAL ENG

19

OD

C-5

WP-1

WP-1

3 WP-1

OD

6"

F RE

FF

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, K INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

C

LL3

34'-0"

__________

REVISEELECTRICAL ANDENGRESUBMIT - ALL Power Design, Inc 11600 Ninth Street North DW Petersburg, FL 33716 727.210.0492 www.powerdesigninc.us

1 SIM L501

__________

C-2

FD

6

CP-1

B3 SOUTH PATIO & PATH REFER TO SHEETS L205 FOR ENLARGED PLANS

9 SIM L501

4

RFI 384 R1

10411 Motor City Dr, St 550 Bethesda, MD 20817 202.466.2232 www.edg2.com

FE

__________

FD

CP-1

MECHANICAL ENG - HOTEL

G

2 L603

2 L600

__________

19

APPROVED EDG2 Engineering Design Group

WP-1

CP-1

OD C

C

OD

KTA Group

LK1

JJ

C

CP-1 C

C-5

1 SIM L501

__________

Worldgate Dr, St 100 REVIEWED12950 BY: Herndon, VA 20170

LK1

WP-1

6

C-2 C-2 ALIGNED WITH BUILDING FACE

SIM 7 L502

__________

MECHANICAL ENG - RESI

CP-1

FD

4 L601

__________

12950 Worldgate Dr, St 100FD Herndon, VA 20170 703.713.0300 www.ktagroup.com

C-5

6 CP-1

6

EE

SUBMITTAL: DATE:

E3.07

LL3

CENTRAL COURTYARD REFER TO SHEETS L206 FOR ENLARGED PLANS

C-5

C-5

4 SIM L501

6

C

4 SIM L501

__________

C-5

FE

WP-1

36'-8"

4

PLUMBING ENG __________ - ALL 1 L605

JH

C-5

10. SEE CIVIL PLANS FOR DETAILS OF OFF-STRUCTURE BIORETENTIONTECHNICAL AREAS.

LK1

LK1

C-5

__________

P-1

C

OD

A315

6

6

36'-9"

5 L503

__________

36'-9"

CLIENT REQUIRED KTA GroupAPPROVAL

F EC

HH

FD

C

Exterior

SITE SIGNAGE

RFI 419

37'-6"

CP-1

CL-1

__________

19 1 SIM L501

__________

1 L608

8

C

LK1

LK1

__________

9 SIM L501

C-5

6 WP-1

8

10

22

DRAWN BY

CIVIL ENGINEERING

11860 Sunrise Valley Dr, St 200 Reston, VA 20191 703.390.7600 www.wilesmensch.com

39'-2"

1 L600

__________

APPROVAL BY DESIGNER AND OWNER PRIOR 19 NOT LIMITED TO TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE LIGHTING DESIGN - RESI SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, Power Design, Inc SAMPLES OF11600 MATERIALS, COLOR APPLICATIONS, AND FINISHES. 11. SEE CIVIL PLANS FOR EXTENT OF CONCRETE CURB AT NEW JERSEY AVENUE. Ninth Street North

WC-3

6

FD

C-2

K

C-5

C-2

2 L504

C-5

34'-0"

__________

WINDOW WELLS

WC-3

FD

Q

FD

9

04.21.2021 FD

FD

CP-1

SHEET NAME Wiles Mensch Corporation

H2O RATED ACCESS HATCH, FLUSH WITH FINISH GRADE

12. ALL GRANITE CURBS TO HAVE 1/4" CHAMFERED CORNERS.

DW

4 L607

__________

C-2 ALIGNED WITH TRENCH DRAIN

37'-2"

GF UNIT TERRACE

FD

CL-1

Design-Build Package - POST FINAL REVISED

GRANITE CURB AND BRICK GUTTER PER DDOT STANDARDS, SEE CIVIL DWGS FOR DETAILS

__________

F RE

FE

1'-6"

8

21

STRUCTURAL ENGINEERING C-5

12435 Park Potomac Ave, C-2St 300 Potomac, MD 20854 301.881.1441 www.skaengineers.com

FD

CP-1

C-5

CL-1

OD

G

6"

CENTRAL WATER FEATURE

3 L611

__________

9. BIORETENTION AND PERMEABLE PAVING 35UNDERDRAINS TO BE 4 OR 6 INCH Minneapolis, MN 55402 RIGID SCHEDULE 40 PVC PIPE, WITH 3/8 INCH PERFORATIONS AT 6 INCHES ON SUBMITTALS REQUIRING 612.977.3500 CENTER. www.dlrgroup.com

FD

J

J

7

20

7

DOCUMENT NAME / SUBMITTAL DATE Smislova, Kehnemui & Assoc

CL-1

1/8" = 1'-0"

FD

TRENCH DRAIN

CP-1

6

520 Nicollet Mall, St 200

WC-3

B3 SOUTH PATIO & PATH - LIGHTING & FURNITURE PLAN

H

MECH SHAFTS

6

GRAVEL SPLASH PAD, SEE CIVIL DWGS FOR DETAIL IN OFF-STRUCTURE BIORETENTION PLANTERS

f 202.600.7280 info@r2l-architects.com

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE GG 6 8. ALL CONCRETE WALLS AND CURBS SHALL BE FINISHED WITH ELASTOMERIC TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PAINT. SAMPLES OF SPECIFIED COLOR WILL BE PROVIDED TO R2L FOR REVIEW INTERIOR DESIGN - HOTEL PERMITTING PRIORDLRTO FABRICATION. H AND APPROVAL PRIOR TO INSTALLATION C-5 CL-1 Group

6

CL-1

P

5

19

7. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL PRECAST/CAST STONE, DIMENSIONAL STONE, AND ALL METAL/GLASS FABRICATIONS

CL-1

C

SCALE:

STEPPED SEATING AND BENCHES

NOTE

WC-3

GG

6

H

2

4

6. REFER TO ARCHITECURAL & STRUCTURAL DRAWINGS FOR MORE INFORMATION ON CONCRETE SLABS AND PLANTER WALL DETAILS/DIMENSIONS.

E3.02

A315

5

E3.03

FD

7

MOVEABLE PLANTERS

5. CROSS & DRAINAGE SLOPES AT PAVER AND DECKING PEDESTRIAN SURFACES SHALL NOT EXCEED 2% IN ANY DIRECTION.

6

CP-1

__________

RFI 408

3

CL-1

FD

E

3. REFER TO L2 SERIES DRAWINGS FOR ENLARGED PLANTING, PAVING, LIGHTING AND FURNITURE PLANS.

FD

LK1

6 A310

LK1

BOLLARD POWER STATION

2. REFER TO SHEET L100 FOR MATERIAL AND LIGHTING SCHEDULES.

WP-1

3

1 L503

6

18

4. REFER TO L5 SERIES SHEETS FOR LANDSCAPE AND HARDSCAPE DETAILS.

6

5

AREA DRAINS PER CIVIL

1. REFER TO SHEET L100 FOR ADDITIONAL NOTES, ABBREVIATIONS & SYMBOLS.

OD

DW

A311

17

CP-1

5 L505

__________

Illume Capitol Yards - Wayfinding & Signage Program DD 3222 N ST NW SUITE 500 DC 20007 Project No. Washington, 86822 t 202.600.7230

GENERAL NOTES

LK1

__________

4

LL3

1

A315

LK1

CAPITOL BIKESHARE STATION

ARCHITECTURAL DESIGN LANDSCAPE DESIGN INTERIOR DESIGN - RESI

4 C-5

TO

WITH

1 A328

LK1

LK1

LL3

6

__________

2

LK1

WP-1 OD

C

MANHOLE COVER, SEE CIVIL

C

A315

FD

16

6

R PAVE N C-2 LL ALIG TER WA PLAN

1

6

CP-1

A315 11

8

A302

LL3

FD

A311

LK1

4

WP-1

EE WP-1

F

AC HOTEL SIGNAGE

WP-1

CP-1

LK1

C

LK1

CP-1

FD

3 __________ L506

A312

LK1 LL3

CL-1

4

E3.06

WP-1

LL3

FD

K

WP-1

FD

LK1

LL3

6

8

FD

FD

WT-1

LK1

1

LK1

WT-1

OD

WP-1

C

LL3

WT-1

WP-1

LL3

A312

J

WT-1

6 A-2

OD

3

WP-1

KING DEC OOD LL NW ALIG TER WA N PLA

C-5

KEYNOTES FD

CP-1

19

C

CC

4 L502

36'-2"

LL3

DD

WT-1

A315 LK1

CP-1

CP-1

C

A301

C

LK1

LL3

FD

CL-1

LK1

WP-1

1

C-5

FD

WP-1

7 WC-3

2

FD

LK1

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

CP-1

LL3

LK1 CENTRAL COURTYARD CP-1 REFER TO SHEETS L206 FOR ENLARGED WT-1 PLANS

6

C

LK1

8

E3.05

6

E

AQ1

3

A311

4

LL3

A315

5

C

4

P

H

C

6

WP-1

WP-1

AQ1

OD

CP-1

__________

LK1

LK1 A309

FD

36'-2"

OD

LL3 LL3

CL-1 3

1 SIM L501

__________

C-2

LK1

LL3

CP-1

5 L603

__________

C

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

6

LK1

6

19

D

CC

A-2 FD

FD

DW

Q

WP-1

WP-1

OD

2 L504

FD

C

CP-1

1 L603

__________

BB

FE

LL3 WP-1

LK1

__________

F RE

FE

4

C

19

main 410.255.6400 | 800.854.0568 gablecompany.com

FD

WP-1

LL3

37

4

LK1

A310 1

SIM 1 L501

__________

A325

39'-2"

9 __________ 6 A813 A363

__________

Q

CP-1

36'-6"

CP-1

K

UP

9 __________ 6 A813 A363

LK1 C

D

5

8 A813

__________

LK1

C

RIOR OF BUIL 44'-8DING 9/16"

7440 Fort Smallwood Rd. Baltimore, MD 21226

__________

__________

Q

C-5 7 __________ A813 ALIGN C-2 PAV ER WITH EXTE

3 L603

__________

C-5

__________

19

AA

5

8 A813

LK1

LK1

K

C

L614

LK1

C

2 L503

__________

6

FD

4 L603

__________

LK1

REF

AA

C-5

__________

LK1

N PERIMETER DR REFER TO SHEE L201 & L202 FO ENLARGED PLA

2 SIM L501

__________

7 A813

6

FD

2

ASI 017 RFI 408 RFI 346 ISSUE FOR CONSTRUCTION ASI 013

10/09/20 09/02/20 08/06/20 04/03/20 03/16/20

31

SHEET NO.

8.02

4

CAPITAL YARD CONNECTION REFER TO SHEE L207 & L208 FOR ENLARGED PLAN


202.466.2232 www.edg2.com

2. REFER TO SHEET L100 FOR MATERIAL AND LIGHTING SCHEDULES.

ELECTRICAL ENG - ALL

3. REFER TO L2 SERIES DRAWINGS FOR ENLARGED PLANTING, PAVING, LIGHTING AND FURNITURE PLANS.

Power Design, Inc 11600 Ninth Street North Petersburg, FL 33716 727.210.0492 www.powerdesigninc.us

4. REFER TO L5 SERIES SHEETS FOR LANDSCAPE AND HARDSCAPE DETAILS. 5. CROSS & DRAINAGE SLOPES AT PAVER AND DECKING PEDESTRIAN SURFACES SHALL NOT EXCEED 2% IN ANY DIRECTION.

GEOTECHNICAL ENG ENVIRONMENTAL ENG

6. REFER TO ARCHITECURAL & STRUCTURAL DRAWINGS FOR MORE INFORMATION ON CONCRETE SLABS AND PLANTER WALL DETAILS/DIMENSIONS.

K

1

A321

JJ

C-5

1

6

C-5

P-2

CP-1

3 LQ2 __________ L601 OD

CP-1

P-1

OD

P-1

4

2 L601

__________

E10-1.05

FFC-2

4 L504LQ2

2 AH360

C-5 9 SIM L501 6

7 A803

HF

P-1

P-1

1 SIM L501

SIM 3 A802

6 C-5 GR-1

C-5

FD

4 L506

GR-1

5

E3.01

2 L602

__________

35'-6"

C-5

6

C-5 C-5

HG

C-5

SIM 8 L502

10 SIM A802

6 L502

__________ FD

__________

C-6

HG

RFI 346

6

9 A802

C-5

Sim

E10-2.01 __________

4 SIM L507 5 C-5

3 L507

A764

__________

FD

HH

C-6 PERPENDICULAR TO C-5, ALIGNED WITH MECH SHAFT 5 WALL

Sim

8 A802

__________

3 SIM A802

6 __________ L608

AH272

C-5

C

4

HI

__________

HI

6

__________

RFI 346 RFI 335 ISSUE FOR CONSTRUCTION ASI 013 ASI 006 98% CONSTRUCTION DOCUMENTS ISSUE

C-5 C-6 PERPENDICULAR TO C-5

LEGEND

HJ C-6

8

JJ

U.C.

1

REF.

6

CMU WALL

JJ

U.C.

REF.

CONCRETE COLUMNS 6

C-5

SLOPED COLUMNS

6

__________

HK

16

LINEAR PAVERS

24

30

31

AH315

32'-6"

KK 34

33

35

FLOOR / ROOF DRAINS, SEE PLUMBING OVERFLOW DRAIN , SEE PLUMBING

C

CLEANOUT DRAIN, SEE PLUMBING

1/8" = 1'-0"

BZA.09

1

1 AH342

__________

DRAWING NUMBER

F EC

HL

6 AH342

__________

GR-1

F EC

LL

LL 7 AH342

7 AH342

__________

__________

HM

HM

2 L604

__________

C

8 AH342

OD

2

A324

__________

MM

OD

4 AH342

__________

LQ2 2 AH342

__________

HN

4 AH342

3

C C

50'-2"

NN

2 AH902

3 L604

HP

__________

35'-0"

2

C

C

C-5

ELECTRICAL ENG - ALL

Power Design, Inc 11600 Ninth Street North Petersburg, FL 33716 727.210.0492 www.powerdesigninc.us GEOTECHNICAL ENG ENVIRONMENTAL ENG

GeoConcepts Engineering, Inc 19955 Highland Vista Dr, St 170 Ashburn, VA 20147 703.726.8030 www.geoconcepts-eng.com INTERIOR DESIGN - HOTEL

DLR Group 520 Nicollet Mall, St 200 Minneapolis, MN 55402 612.977.3500 www.dlrgroup.com LIGHTING DESIGN - RESI

Power Design, Inc 11600 Ninth Street North Petersburg, FL 33716 727.210.0492 www.powerdesigninc.us

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

SECTION LEGEND

ISSUE FOR CONSTRUCTION ASI 013 ASI 006 98% CONSTRUCTION DOCUMENTS ISSUE

04/03/20 03/16/20 12/12/19 11/08/19 DATE

SHEET NO.

GREYSTAR GP II, LLC 8405 GREENSBORO DRIVE, STE 500 MCLEAN, VA 22102

8.03 OWNER

CONCRETE COLUMNS

CSX EAST 861 NEW JERSEY AVENUE, SE WASHINGTON, DC 20003

SLOPED COLUMNS

PROJECT TRUE NORTH

__________

OD

HP

JH

EDG2 Engineering Design Group 10411 Motor City Dr, St 550 Bethesda, MD 20817 202.466.2232 www.edg2.com

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

8 Locations and Messages CMU WALL

13/16"

61/1

A325

19

OD

DRAWN BY

MECHANICAL ENG - HOTEL

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE WPF Engineering, LLC TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND 1671 House Street NE Belmont, MI 49306 PERMITTING PRIOR TO FABRICATION. 616.340.9627

AREAS OF VEHICULAR CIRCULATION

1' - 9

2' - 2

NN

SIM 4 L503

__________

17' - 0"

2 AH902

__________

2"

GR-1

28" 6 67/1

35'-0"

LK1

HN

2 AH342

__________

19

1 L604

MECHANICAL ENG - RESI

__________

6 L506

__________

__________

REVISE AND RESUBMIT

04.21.2021

KTA Group 12950 Worldgate Dr, St 100 Herndon, VA 20170 703.713.0300 www.ktagroup.com

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

8 AH342

__________

MM

8. ALL CONCRETE WALLS AND CURBS SHALL BE FINISHED WITH ELASTOMERIC PAINT. SAMPLES OF SPECIFIED COLOR WILL BE PROVIDED TO R2L FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION

PLUMBING ENG - ALL

KTA Group 12950 Worldgate Dr, St 100 Herndon, VA 20170 703.713.0300 www.ktagroup.com

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

C-1

C

CIVIL ENGINEERING

Wiles Mensch Corporation 11860 Sunrise Valley Dr, St 200 Reston, VA 20191 703.390.7600 www.wilesmensch.com

www.wpf-engineering.com

GR-2

BIORETENTION / PERMEABLE PAVING UNDERDRAIN

__________

STRUCTURAL ENGINEERING

Smislova, Kehnemui & Assoc 12435 Park Potomac Ave, St 300 Potomac, MD 20854 301.881.1441 www.skaengineers.com

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

PLANTER WALL COPING

HL

6 AH342

C-5

AREA DRAIN, SEE CIVIL TRENCH DRAIN

CAPITAL YARDS CONNECTION - PAVING PLAN SCALE:

2. REFER TO SHEET L100 FOR MATERIAL AND LIGHTING SCHEDULES.

TITLE

L207

BIORETENTION PLANTER

FD OD

AD

1

CAPITAL YARDS CONNECTION PAVING PLAN

6

GREEN ROOF PLANTER

22

23

6

8" 7'-5 5/

1 AH342

HK

GRAPHIC SCALE

WEIR, TOP OF WALL @ PONDING LEVEL PER CIVIL C-5

3222 N ST NW SUITE 500 Washington, DC 20007 t 202.600.7230 f 202.600.7280 info@r2l-architects.com

LIGHTING DESIGN - HOTEL

E1

RFI 253

CONCRETE ROAD

9 AH342

__________

GRANITE PAVERS (PATTERNED)

21

__________

Exterior GENERAL NOTES 1. REFER TO SHEET L100 FOR ADDITIONAL NOTES, ABBREVIATIONS & SYMBOLS. CLIENT REQUIRED APPROVAL

NOTE12. ALL GRANITE CURBS TO HAVE 1/4" CHAMFERED CORNERS.

11 AH342

__________ PLAN NORTH

C-5

KK

CONC MECHANICAL PAD

11. SEE CIVIL PLANS FOR EXTENT OF CONCRETE CURB AT NEW JERSEY AVENUE.

DC SIDEWALK (TYP) 6

CAPITOL YARDS ACCESS

APPROVED AS NOTED

8" 1'-2 1/

PP

6

4 14

11

10. SEE CIVIL PLANS FOR DETAILS OF OFF-STRUCTURE BIORETENTION AREAS.

PROJECT TRUE NORTH

UNILOCK CONC PAVER

EYE STREET SITE ENTRY REFER TO SHEET L210 FOR ENLARGED PLANS

C-2

A326 A736

PEPCO VAULTS DOCUMENT NAME / SUBMITTAL DATE

9. BIORETENTION AND PERMEABLE PAVING UNDERDRAINS TO BE 4 OR 6 INCH RIGID SCHEDULE 40 PVC PIPE, WITH 3/8 INCH PERFORATIONS AT 6 INCHES ON CENTER.

PORCELAIN WOOD LOOK TILE

FD

11 AH342

__________

9 AH342

HJ

CSX EAST 861 NEW JERSEY AVENUE, SE WASHINGTON, DC 20003

C-3

FD

NN

RFI 419

BOD: FANCY FENCE

APPROVED

OWNER

A324

10

22

7. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL PRECAST/CAST STONE, DIMENSIONAL STONE, AND ALL METAL/GLASS FABRICATIONS

AREAS OFC-5VEHICULAR CIRCULATION

C-5

ARCHITECTURAL DESIGN LANDSCAPE DESIGN INTERIOR DESIGN - RESI

SITE SIGNAGE Illume Capitol Yards - Wayfinding & Signage Program WINDOW WELLS Project No. 86822 RETRACTABLE GATE

6. REFER TO ARCHITECURAL & STRUCTURAL DRAWINGS FOR MORE INFORMATION ON CONCRETE SLABS AND PLANTER WALL DETAILS/DIMENSIONS.

08/06/20 07/10/20 04/03/20 03/16/20 12/12/19 11/08/19 DATE

GREYSTAR GP II, LLC 8405 GREENSBORO DRIVE, STE 500 MCLEAN, VA 22102

C-5

C

7 __________ L506

WITH FINISH GRADE

SHALL NOT EXCEED 2% IN ANY DIRECTION.

35'-6" C-3

DN

MM

21

GF UNIT TERRACE

4. REFER TO L5 SERIES SHEETS FOR LANDSCAPE AND HARDSCAPE DETAILS.

2 L613

107.5°

15 A802

12

A326

8

5. CROSS & DRAINAGE SLOPES AT PAVER AND DECKING PEDESTRIAN SURFACES REVIEWED BY:

8"

9

__________

3

7

AND FURNITURE PLANS. SUBMITTAL: DATE:

HH

FD

RFI 335

20

6

3. REFER TO L2 SERIES DRAWINGS FOR ENLARGED PLANTING, PAVING, LIGHTING

C-5

C-6

GRAVEL SPLASH PAD, SEE CIVIL DWGS

15

19

5

DN

12

19

4

SHEET NAME WEST BIORETENTION YARD

6 19

3

BOLLARD POWER STATION

13

36'-5"

6

18

SEATING DETAIL IN OFF-STRUCTURE GraystarSTEPPED Worldwide, LLC FOR AND BENCHES BIORETENTION PLANTERS 8405 Greensboro Drive, Suite 500 MECH SHAFTS GRANITE CURB AND BRICK GUTTER PER DDOT STANDARDS, SEE CIVIL McLean,TRENCH VA 22102 DRAIN DWGS FOR DETAILS 859-327-2628 CENTRAL WATER FEATURE H2O RATED ACCESS HATCH, FLUSH

14

C

__________

6

LL

6

AREA DRAINS PER CIVIL

12

OD

A323

4

17

Design-Build Package - POST FINAL REVISED SECURE ACCESS GATE

C-3

36'-8"

C-5

35'-8"

CAPITOL BIKESHARE STATION

10

GG

E3.04

__________

2

35'-6"

GR-1

C-5

GG

MANHOLE COVER, SEE CIVIL

9

C-5

34'-0"

FD

NEW JERSEY AVE STREETSCAPE REFER TO SHEET L211 FOR ENLARGED PLANS

6

GR-2 5 L507

__________

16

5

GR-2

CP-1

C-6 PERPENDICULAR TO C-5, ALIGNED WITH MECH SHAFT C-6 WALL

9

CP-1

__________

C-5

GR-2

1 L506

__________

2 L610

__________

6

6

F EC

AC HOTEL SIGNAGE

3

C-5 NEW JERSEY AVE STREETSCAPE REFER TO SHEET L211 FOR ENLARGED PLANS

1

OWNERMOVEABLE / ADDRESS / PROJECT NAME / PROJECT NO. PLANTERS HF

C

SL-1

GR-2

C-6 PERPENDICULAR TO PLANTER WALL

__________

2 AH360

__________

DN

CP-1

CP-1

C-6

FD

3 SIM L505

__________

C-1

WPF Engineering, LLC 1671 House Street NE Belmont, MI 49306 616.340.9627 www.wpf-engineering.com

FF

__________

__________

C-5

__________

GR-2

9

FD

KK

C

5 L607

DN

L602

5 C-5

12. ALL GRANITE CURBS TO HAVE 1/4" CHAMFERED CORNERS.

OD

KEYNOTES

C-4

LIGHTING DESIGN - HOTEL

1

2

AH813

__________

__________

8

AH732

4

CP-1 P-1

OD

5 L604

GR-2

main 410.255.6400 | 800.854.0568 gablecompany.com

LIGHTING DESIGN - RESI

Power Design, Inc 11600 Ninth Street North 2 SIM Petersburg, FL 33716 __________ 727.210.0492 L505 www.powerdesigninc.us

11. SEE CIVIL PLANS FOR EXTENT OF CONCRETE CURB AT NEW JERSEY AVENUE.

AH732

CP-1

6

16

10. SEE CIVIL PLANS FOR DETAILS OF OFF-STRUCTURE BIORETENTION AREAS.

__________

__________

CP-1

4 L503

__________

2 L608

7440 Fort Smallwood Rd. Baltimore, MD 21226

INTERIOR DESIGN - HOTEL

DLR Group 520 Nicollet Mall, St 200 Minneapolis, MN 55402 612.977.3500 www.dlrgroup.com

9. BIORETENTION AND PERMEABLE PAVING UNDERDRAINS TO BE 4 OR 6 INCH RIGID SCHEDULE 40 PVC PIPE, WITH 3/8 INCH PERFORATIONS AT 6 INCHES ON CENTER.

__________

1 L601

C-5

P-1 C-5

C

61

FOR ENLARGED PLANS

CP-1

__________

C

GR-2

19

C-5

C-2

60 SHALL BE FINISHED WITH ELASTOMERIC 8. ALL CONCRETE WALLS AND CURBS POCKET PARK PAINT. SAMPLES OF SPECIFIED COLOR WILL BE PROVIDED TO R2L FOR REVIEW REFER TO SHEET L212 AND APPROVAL PRIOR TO INSTALLATION

GR-2

16

P-1 19

7. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL PRECAST/CAST STONE, DIMENSIONAL STONE, AND ALL METAL/GLASS FABRICATIONS

35'-0"

61

POCKET PARK REFER TO SHEET L212 FOR ENLARGED PLANS BZA.07 P-1

C-5

6

B3 SOUTH PATIO & PATH REFER TO SHEET L205 FOR ENLARGED PLANS

C-1

CENTRAL COURTYARD REFER TO SHEET L206 FOR ENLARGED PLANS

60 GR-2

GeoConcepts Engineering, Inc 19955 Highland Vista Dr, St 170 Ashburn, VA 20147 703.726.8030 www.geoconcepts-eng.com

PORCELAIN WOOD LOOK TILE UNILOCK CONC PAVER

PLAN NORTH


L209 FOR ENLARGED PLANS

8

CAPITAL YARDS CONNECTION REFER TO SHEETS L207 & L208 FOR ENLARGED PLANS

35'-0"

GR-1

OD

PP

C-5

C-5

10

FD

EE C-3

RETRACTABLE GATE BOD: FANCY FENCE

RFI 419

PEPCO VAULTS

12

CAPITOL YARDS ACCESS

13

SECURE ACCESS GATE

14

CONC MECHANICAL PAD

15

WEST BIORETENTION YARD

1

RFI 316

SIM 8 __________ L504

C-2

3 __________ A803

C-1

32'-4 7/8" RFI 419

22'-0"

8'-11 1/8" 10'-0"

33'-6" C-1

6 L507

__________

BEGIN MOUNTABLE CURB

C-6

RFI 419

1'-2 1/8" 3'-0 1/4" 7'-10"

2'-10 7/8" 30'-4 3/16"

RFI 419

29'-9 1/4"

1/8" = 1'-0"

6. REFER TO ARCHITECURAL & STRUCTURAL DRAWINGS FOR MORE INFORMATION ON CONCRETE SLABS AND PLANTER WALL DETAILS/DIMENSIONS. 7. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL PRECAST/CAST STONE, DIMENSIONAL STONE, AND ALL METAL/GLASS FABRICATIONS 8. ALL CONCRETE WALLS AND CURBS SHALL BE FINISHED WITH ELASTOMERIC PAINT. SAMPLES OF SPECIFIED COLOR WILL BE PROVIDED TO R2L FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION

8'-8"

N PERIMETER DRIVE SHEETS 10.REFER SEE TO CIVIL PLANS L201 & L202 FOR ENLARGED PLANS

C-5

3'-6"

C-5

GR-2

16

HC

RFI 232R1 ME-1 C-3

6

PAVERS ALIGNED WITH TRENCH DRAIN

C-1

C-5

C-2

1'-6"

3

04.21.2021

SHEET NAME

DRAWN BY

Exterior

JH

SUBMITTAL: DATE:

1 L507

__________

APPROVED

ME-1

1 L602

__________

4 L604

1 L606

SL-1

8' - 8"

1'-6"

BZA.08

REVIEWED BY: DN

SL-1

__________

__________

10'-10 3/4 "

C

ME-1

SL-1

C-5

HD

REVISE AND RESUBMIT

ME-1

__________

26'-10" C

11'-1 3/4"

5 L609

6

C

1'-6"

C-5

__________

C-5

1'-6"

GR-2

F EC

C-5

E2

3 L504

NOTE HE

2 L609

__________

1'-6"

C

3'-6 7/8 " 1'-6"

3 L609

__________

1'-6"

6'-3 5/8"

1'-6"

22 C-5

3'-5 1/4"

8'-6" 6

C

AD

E5-01

25'-1 7/16"

C

C

GR-2 4 L503

__________

LEGEND

EE

SIM 6 24'-0" L504

OWNER

6

2 L902

1 L902

6

CSX EAST HOTEL AVENUE, ARRIVAL SE 861 NEW JERSEY REFER TO SHEET WASHINGTON, DC 20003 L209 FOR

CONCRETE COLUMNS

36 1

__________

__________

__________

C-5

C-5

C-5

CMU WALL

SIM 7 L504 12'-11 1/8"

AD

__________

POCKET PARK - PAVING PLAN SCALE:

SLOPED COLUMNS

ENLARGED PLANS

PROJECT TRUE NORTH

37

PORCELAIN WOOD LOOK TILE UNILOCK CONC PAVER

1/8" = 1'-0"

PLAN NORTH

GRANITE PAVERS (PATTERNED)

RFI 419

LINEAR PAVERS

C-4 C-4

DC SIDEWALK (TYP) CONCRETE ROAD GREEN ROOF PLANTER FD

FLOOR / ROOF DRAINS, SEE PLUMBING

OD

OVERFLOW DRAIN , SEE PLUMBING

C

AD

RFI 253

WEIR, TOP OF WALL @ PONDING LEVEL PER CIVIL BIORETENTION PLANTER

CLEANOUT DRAIN, SEE PLUMBING AREA DRAIN, SEE CIVIL TRENCH DRAIN

1

EYE STREET SITE ENTRY - PAVING PLAN SCALE:

1/8" = 1'-0"

09/30/20 08/18/20 07/23/20 07/10/20 07/01/20 04/03/20 03/16/20 01/16/20 12/12/19 11/08/19 DATE

GREYSTAR GP II, LLC 8405 GREENSBORO DRIVE, STE 500 MCLEAN, VA 22102

__________

C-5

RFI 419 RFI 253R1 RFI 358 RFI 335 RFI 316 ISSUE FOR CONSTRUCTION ASI 013 RFI 028R1 ASI 006 98% CONSTRUCTION DOCUMENTS ISSUE

PLANTER WALL COPING BIORETENTION / PERMEABLE PAVING UNDERDRAIN

CONCRETE COLUMNS

CSX EAST 861 NEW JERSEY AVENUE, SE WASHINGTON, DC 20003

SLOPED COLUMNS

PROJECT TRUE NORTH

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE PORCELAIN WOOD LOOK TILE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND UNILOCK CONC PAVER PERMITTING PRIOR TO FABRICATION.

16

RFI 253 PAVERS SUBMITTALS REQUIRINGLINEAR APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT@ LIMITED TO POCKET PARK DC SIDEWALK (TYP) WEIR, TOP OF WALL PONDING LEVEL PER CIVIL TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, CONCRETE ROAD SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

GRAPHIC SCALE

TITLE

GREEN ROOF PLANTER

BIORETENTION PLANTER

L212

FLOOR / ROOF DRAINS, SEE PLUMBING WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL OVERFLOW DRAIN , SEE PLUMBING COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, CLEANOUT DRAIN, SEE PLUMBING VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN AD AREA DRAIN, SEE CIVIL MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL TRENCH DRAIN BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO PLANTER WALL COPING FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS BIORETENTION / PERMEABLE PAVING UNDERDRAIN AND APPROPRIATE MOUNTING METHODS. FD

NEW JERSEY AVE STREETSCAPE REFER TO SHEET L211 FOR ENLARGED PLANS

OD C

GRAPHIC SCALE

EYE STREET SITE ENTRY TITLE

L210 DRAWING NUMBER

PLAN NORTH

GRANITE PAVERS (PATTERNED)

AREAS OF VEHICULAR CIRCULATION

6 L609

4 L609

__________

3'-5 1/4"

7 SIM L504

__________

C

1

1'-0"

C

RFI 419

GR-2 C-5

4"

9'-4 3/4 "

ALIGN C-2 PAVER PERPENDICULAR WITH EXTERIOR OF BUILDING

C

1'-6"

OWNER

CMU WALL

C

C-2

16

AREAS OF VEHICULAR CIRCULATION

__________

GR-2

09/28/20 04/03/20 03/16/20 12/12/19 11/08/19 DATE

GREYSTAR GP II, LLC 8405 GREENSBORO DRIVE, STE 500 MCLEAN, VA 22102

APPROVED AS NOTED

19' - 1"

GR-1

C-5

5'-10"

RFI 232R1 ISSUE FOR CONSTRUCTION ASI 013 ASI 006 98% CONSTRUCTION DOCUMENTS ISSUE

LEGEND

16

DD

6 SIM L504

1 L609

__________

WPF Engineering, LLC 1671 House Street NE Belmont, MI 49306 616.340.9627 www.wpf-engineering.com

Design-Build Package - POST FINAL REVISED

90.1 °

OD C

LIGHTING DESIGN - HOTEL

CLIENT REQUIRED APPROVAL

" 0' - 11

9 SIM L501

SIM C-1

C-1

__________

C

3 L508

__________

30'-4"

170.0° 2

C-5

CC

28'-3 5/16"

6

1' - 6"

0' - 4"

6

1' - 9" 22' - 9"

52'-10"

C-2

1 L504

__________

LIGHTING DESIGN - RESI

Power Design, Inc 11600 Ninth Street North Petersburg, FL 33716 727.210.0492 www.powerdesigninc.us

DOCUMENT NAME / SUBMITTAL DATE HB

2' - 7"

" 9' - 10 C-5

__________

C-5

1

P. 2' - 6" TY

6' - 3"

INTERIOR DESIGN - HOTEL

DLR Group 520 Nicollet Mall, St 200 Minneapolis, MN 55402 612.977.3500 www.dlrgroup.com

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

61

0' - 7"

AD

30'-4 3/16"

SIM 7 L504

HA

62

P. 3' - 1" TY

C-5

6

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628

C-4

" 5' - 10

16

C-5

SIM 7 L504

__________

3 SIM L503

__________

GEOTECHNICAL ENG ENVIRONMENTAL ENG

GeoConcepts Engineering, Inc 19955 Highland Vista Dr, St 170 Ashburn, VA 20147 703.726.8030 www.geoconcepts-eng.com

6' - 3"

E11.03

31'-6"

C-5

63

" 3' - 10

E11.01

2 L605

C-5

OWNER / ADDRESS / PROJECT / PROJECT NO. 12. ALL GRANITE CURBS TO HAVE 1/4"NAME CHAMFERED CORNERS.

LIGHTING DESIGN - HOTEL

WPF Engineering, LLC 1671 House Street NE Belmont, MI 49306 616.340.9627 www.wpf-engineering.com

10. SEE CIVIL PLANS FOR DETAILS OF OFF-STRUCTURE BIORETENTION AREAS. 11. SEE CIVIL PLANS FOR EXTENT OF CONCRETE CURB AT NEW JERSEY AVENUE.

Power Design, Inc 11600 Ninth Street North Petersburg, FL 33716 727.210.0492 www.powerdesigninc.us

12. ALL GRANITE CURBS TO HAVE 1/4" CHAMFERED CORNERS.

ELECTRICAL ENG - ALL

Power Design, Inc 11600 Ninth Street North Petersburg, FL 33716 727.210.0492 www.powerdesigninc.us

main 410.255.6400 | 800.854.0568 gablecompany.com

9. BIORETENTION AND PERMEABLE PAVING UNDERDRAINS TO BE 4 OR 6 INCH RIGID SCHEDULE 40 PVC PIPE, WITH 3/8 INCH PERFORATIONS AT 6 INCHES ON CENTER.

NEW JERSEY AVE STREETSCAPE REFER TO SHEET L211 FOR ENLARGED PLANS

LIGHTING DESIGN - RESI

FOR DETAILS OF OFF-STRUCTURE BIORETENTION AREAS.

60 17 JERSEY AVENUE. 11. SEE CIVIL PLANS FOR EXTENT OF CONCRETE CURB AT NEW

__________

7 SIM L504

8. ALL CONCRETE WALLS AND CURBS SHALL BE FINISHED WITH ELASTOMERIC PAINT. SAMPLES OF SPECIFIED COLOR WILL BE PROVIDED TO R2L FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION

INTERIOR DESIGN - HOTEL

6

__________

7. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL PRECAST/CAST STONE, DIMENSIONAL STONE, AND ALL METAL/GLASS FABRICATIONS

DLR Group 520 Nicollet Mall, St 200 Minneapolis, MN 55402 612.977.3500 www.dlrgroup.com

EDG2 Engineering Design Group 10411 Motor City Dr, St 550 Bethesda, MD 20817 202.466.2232 www.edg2.com

7440 Fort Smallwood Rd. Baltimore, MD 21226

16

GEOTECHNICAL ENG ENVIRONMENTAL ENG

6 SIM L504

25'-8 5/8"

30'-4 3/16"

1

GeoConcepts Engineering, Inc 19955 Highland Vista Dr, St 170 Ashburn, VA 20147 703.726.8030 www.geoconcepts-eng.com

__________

30'-4 3/16" C

5. CROSS & DRAINAGE SLOPES AT PAVER AND DECKING PEDESTRIAN SURFACES SHALL NOT EXCEED 2% IN ANY DIRECTION. 6. REFER TO ARCHITECURAL & STRUCTURAL DRAWINGS FOR MORE INFORMATION ON CONCRETE SLABS AND PLANTER WALL DETAILS/DIMENSIONS.

11600 Ninth Street North Petersburg, FL 33716 727.210.0492 www.powerdesigninc.us

9. BIORETENTION AND PERMEABLE PAVING UNDERDRAINS TO BE 4 OR 6 INCH RIGID SCHEDULE 40 PVC PIPE, WITH 3/8 INCH PERFORATIONS AT 6 INCHES ON CENTER.

3'-6"

1'-0 1/2"

4. REFER TO L5 SERIES SHEETS FOR LANDSCAPE AND HARDSCAPE DETAILS.

BZA.07

HOTEL ARRIVAL ELECTRICAL - ALL REFER TOENG SHEET L209 FOR Power Design, Inc ENLARGED PLANS

5. CROSS & DRAINAGE SLOPES AT PAVER AND DECKING PEDESTRIAN SURFACES SHALL NOT EXCEED 2% IN ANY DIRECTION. POCKET PARK - LIGHTING & FURNITURE PLAN SCALE:

3. REFER TO L2 SERIES DRAWINGS FOR ENLARGED PLANTING, PAVING, LIGHTING AND FURNITURE PLANS.

EDG2 Engineering Design Group 10411 Motor City Dr, St 550 Bethesda, MD 20817 202.466.2232 www.edg2.com

1'-0"

37'-4"

1'-8 1/2"

6 7/8"

21'-4"

__________

2

5'-11"

2 L507

ALIGN PERMEABLE PAVER PERPENDICULAR WITH EXTERIOR OF PLANTER WALL

16

11

EDGE OF STRUCTURE BELOW

3'-6"

39'-0 7/8"

FD

2. REFER TO SHEET L100 FOR MATERIAL AND LIGHTING SCHEDULES.

LP-2

HE

KTA Group 12950 Worldgate Dr, St 100 Herndon, VA 20170 703.713.0300 www.ktagroup.com

36 TO L5 SERIES SHEETS FOR LANDSCAPE 37 4. REFER AND HARDSCAPE DETAILS.

16

8'-10"

33'-1"

3'-6"

1 A803

__________

LP-2

MECHANICAL ENG - RESI

3. REFER TO L2 SERIES DRAWINGS FOR ENLARGED PLANTING, PAVING, LIGHTING AND FURNITURE PLANS. PERMEABLE PAVERS TYPICAL PAVERS

2 A803

1. REFER TO SHEET L100 FOR ADDITIONAL NOTES, ABBREVIATIONS & SYMBOLS.

3' - 9"

MECHANICAL ENG - HOTEL

2. REFER TO SHEET L100 FOR MATERIAL AND LIGHTING SCHEDULES.

16 __________

A321

MECHANICAL ENG - HOTEL

GENERAL NOTES

13' - 2"

KTA Group 12950 Worldgate Dr, St 100 Herndon, VA 20170 703.713.0300 www.ktagroup.com

11

16

6

PLUMBING ENG - ALL

1. REFER TO SHEET L100 FOR ADDITIONAL NOTES, ABBREVIATIONS & SYMBOLS. RFI 419

ALIGN C-2 PAVER PERPENDICULAR WITH EXTERIOR OF ADJACENT PROPERTY LINE AT 90 DEGREES

10

SITE SIGNAGE

22

GENERAL NOTES

RFI 419

5 SIM L502

C-5

ALIGN TRENCH DRAIN WITH ADJACENT PLANTER WALL

WINDOW WELLS

END MOUNTABLE CURB

__________

6

__________

RFI 358

RFI 419

ALIGN TRENCH DRAIN WITH ADJACENT PLANTER WALLS

SIM 7 L504

__________

9

FD

21

C-5

6

7 L506

SIM 4 L503

C

12 A343

FD

OD

__________

__________

C-6

RFI 335

35'-0"

C

GF UNIT TERRACE

CIVIL ENGINEERING

Wiles Mensch Corporation 11860 Sunrise Valley Dr, St 200 Reston, VA 20191 703.390.7600 www.wilesmensch.com

" 5' - 11

6

1 L604

H2O RATED ACCESS HATCH, FLUSH WITH FINISH GRADE

21

F EC

5' - 7"

2 AH902

__________

4 A343

__________

__________

CENTRAL WATER FEATURE

7

DD

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

8 Locations and Messages

8.04

DRAWING NUMBER


9

Parking Garage Wayfinding Sign Locations


GARAGE CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

G1.15 G1.04

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

G1.05

A B B A A B

G1.08

G3.04

G1.02

G1.01 A B

G2.05

G2.01

A B

W

DOCUMENT NAME / SUBMITTAL DATE

E

G3.02 G3.01

G3.07

S

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

04.21.2021

Parking Garage - Wayfinding - Floor P1 CLIENT APPROVAL

JH

DRAWN BY

CLIENTApproved REQUIRED APPROVAL G2.10 SUBMITTAL: DATE:

G2.06

G1.06 A B

G3.06

G3.03

G2.04

G2.02

N

G2.08

G1.10

G3.05

G2.03

G1.03

A B

A B

A B

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

Not Approved

REVIEWED BY:

G1.07 G2.09

A B

G2.07

Approved as Noted

APPROVED

G1.12

REVISE AND RESUBMIT

A B

G1.14 A B

B

A

G1.11 G1.13

G3.11

A B

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

P1 Parking Floor 1 Scale: 1:750

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

P1 Parking Floor

SECTION PAGE No.

8 Locations and Messages

GC.1

SHEET NO.

9.01


GARAGE CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE G1.18

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

G1.19 A B

A B

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

G1.16 G3.08

A B

G1.17

G3.09

A B

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

04.21.2021

Parking Garage - Wayfinding - Floor P2 CLIENT APPROVAL

JH

DRAWN BY

CLIENTApproved REQUIRED APPROVAL

G3.10

G1.20

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

A B

Approved as Noted

APPROVED

G3.12

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

P2 Parking Floor 2 Scale: 1:750

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

P2 Parking Floor

SECTION PAGE No.

8 Locations and Messages

GC.5

SHEET NO.

9.02


10

Parking Garage Code Sign Locations and Messages


GARAGE CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE 3F-P1.1

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

3H-P1.1

3H-P1.13

2H-P1.14

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2E-P1.4 2H-P1.15

2H-P1.16

3E-P1.5

DOCUMENT NAME / SUBMITTAL DATE

2H-P1.17 3H-P1.2

2A-P1.3

3H-P1.12 3H-P1.3 3E-P1.1

2H-P1.18

3E-P1.2

3H-P1.11

2C-P1.3

3H-P1.4

2E-P1.3 3H-P1.9

2H-P1.21

2E-P1.6

3H-P1.7 3C-P1.1

3H-P1.6

3H-P1.5

Parking Garage - Code - Floor P1 CLIENT APPROVAL

JH

DRAWN BY

SUBMITTAL: DATE:

Not Approved

2H-P1.24

REVIEWED BY:

2H-P1.22

3A-P1.2

3H-P1.8

04.21.2021

CLIENTApproved REQUIRED APPROVAL

2H-P1.20

3H-P1.10

3A-P1.1

2H-P1.19

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

Approved as Noted

2H-P1.23

APPROVED

3C-P1.2

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

2H-P1.25 2H-P1.26

No.

2A-P1.5 2H-P1.30 2H-P1.31

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

2A-P1.4

2C-P1.4

2H-P1.29

2H-P1.28 2H-P1.27

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

P1 Parking Floor 1 Scale: 1:750

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

P1 Parking Floor

SECTION PAGE No.

8 Locations and Messages

GC.1

SHEET NO.

10.01


LOCATION

MESSAGE

2A : Stair ID (Garage)

2A-P1.3

Stair ID (Garage)

2A-P1.4

Stair ID (Garage)

2A-P1.5

Stair ID (Garage)

Egress Direction (Garage)

CLIENT REMARKS

LOCATION

MESSAGE

Total Qty: 3

2E-P1.4

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Evac/In Case of Fire (Garage)

STAIR 2-1

STAIR P-1

2E-P1.6

Evac/In Case of Fire (Garage)

Total Qty: 2

STAIR 2-1 ROOF ACCESS

2E-P1.3

Evac/In Case of Fire (Garage)

2H-P1.14 Room ID (Garage)

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 18

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations must be site Parking Garage - Code - Floor P1 checked

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

2H-P1.15 Room ID (Garage)

ELEVATOR LOBBY NORTH

Room ID (Garage)

ELEVATOR LOBBY NORTH

P1 LEVEL P1

2H-P1.17

STORAGE

LEVELS P1-G EXIT UP TO GROUND [UP ARROW]

2H-P1.18

DRY PIPE VALVE ROOM

2H-P1.19

GAS METER ROOM

2H-P1.20

ELEVATOR LOBBY SOUTH

Room ID (Garage)

Room ID (Garage)

Total Qty: 3

Room ID (Garage)

Room ID (Garage)

2H-P1.21 [EVAC MAP HOLDER]

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

STORAGE

2H-P1.16

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

STAIR P-1 NO ROOF ACCESS

2E : Evac/In Case of Fire (Garage)

GARAGE CODE SIGNAGE

2H : Room ID (Garage)

LEVELS P1-13 EXIT UP TO LEVEL 1 [UP ARROW]

Egress Direction (Garage)

CLIENT REMARKS

[EVAC MAP HOLDER]

P1 LEVEL P1

2C-P1.4

DESIGNER NOTES

[EVAC MAP HOLDER]

STAIR P-1

2C : Egress Direction (Garage)

2C-P1.3

DESIGNER NOTES

Room ID (Garage)

ELEVATOR LOBBY SOUTH

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

Room is not named on plan. Client to confirm room designation.

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

P1 Parking Floor

8 Locations PAGE No. and Messages

GC.2

10.02


LOCATION

MESSAGE

2H-P1.22

BLDG 2 MAIN ELECTRICAL ROOM

Room ID (Garage)

2H-P1.23 Room ID (Garage)

2H-P1.24 Room ID (Garage)

2H-P1.25 Room ID (Garage)

DESIGNER NOTES

CLIENT REMARKS

LOCATION

3C : Egress Direction (Garage)

3C-P1.1

Egress Direction (Garage)

BLDG 2 MAIN ELECTRICAL ROOM BOOSTER PUMP WATER SERVICE GAS METER ROOM

3C-P1.2 2H-P1.26 Room ID (Garage)

2H-P1.27 Room ID (Garage)

2H-P1.28 Room ID (Garage)

2H-P1.29 Room ID (Garage)

2H-P1.30 Room ID (Garage)

2H-P1.31 Room ID (Garage)

3A-P1.1

Stair ID (Garage)

Egress Direction (Garage)

MAIN TELECOM

Stair ID (Garage)

GARAGE CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

P1 LEVEL P1

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

LEVELS P2-13 EXIT UP TO LEVEL 1 [UP ARROW]

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

STAIR 3-4 ROOF ACCESS

3E : Evac/In Case of Fire (Garage)

MAIN ELECTRICAL ROOM

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations must be site Parking Garage - Code - Floor P1 checked

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

Total Qty: 3

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

3E-P1.1

Evac/In Case of Fire (Garage)

BLDG 2 / BLDG 3 EMERGENCY GENERATOR

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

RESIDENTIAL FIRE PUMP ROOM

STAIR 3-4

Total Qty: 2

STAIR 3-2 ROOF ACCESS

3E-P1.2 Total Qty: 2

Evac/In Case of Fire (Garage)

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

3A-P1.2

CLIENT REMARKS

LEVELS P2-13 EXIT UP TO LEVEL 1 [UP ARROW]

MAIN ELECTRICAL ROOM

STAIR 3-2

DESIGNER NOTES

P1 LEVEL P1

IRRIGATION PUMP FILTER ROOM

3A : Stair ID (Garage)

MESSAGE

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

P1 Parking Floor

8 Locations PAGE No. and Messages

GC.3

10.03


LOCATION

MESSAGE

3E-P1.5

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Evac/In Case of Fire (Garage)

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3H-P1.10

ELEVATOR LOBBY EAST

Room ID (Garage)

3H-P1.11

ELEVATOR LOBBY EAST

3H-P1.12 Room ID (Garage)

BLDG 3 EAST TRASH ROOM

3H-P1.13

STORAGE

Room ID (Garage)

[EVAC MAP HOLDER] 3F : Restroom ID (Garage)

3F-P1.1

Restroom ID (Garage)

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

3H : Room ID (Garage)

3H-P1.1 Room ID (Garage)

Total Qty: 1

MAINTENANCE OFFICE

Room ID (Garage)

Total Qty: 13

DESIGNER NOTES

CLIENT REMARKS

GARAGE CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS Install with vinyl backer.

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations must be site Parking Garage - Code - Floor P1 checked

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3H-P1.2 Room ID (Garage)

BLDG 3 WEST ELECTRICAL ROOM

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3H-P1.3 Room ID (Garage)

BLDG 3 WEST ELECTRICAL ROOM

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

3H-P1.4 Room ID (Garage)

3H-P1.5 Room ID (Garage)

3H-P1.6 Room ID (Garage)

3H-P1.7 Room ID (Garage)

3H-P1.8 Room ID (Garage)

3H-P1.9 Room ID (Garage)

ELEVATOR LOBBY WEST DRY PIPE VALVE ROOM P1 BIKE STORAGE DRY PIPE VALVE ROOM BLDG 3 EAST ELECTRICAL ROOM BLDG 3 EAST ELECTRICAL ROOM

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

P1 Parking Floor

8 Locations PAGE No. and Messages

GC.4

10.04


GARAGE CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

3H-P2.1

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 3E-P2.3

DOCUMENT NAME / SUBMITTAL DATE 3H-P2.6

3E-P2.1

3E-P2.2

3H-P2.2

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

04.21.2021

Parking Garage - Code - Floor P2 CLIENT APPROVAL

JH

DRAWN BY

CLIENTApproved REQUIRED APPROVAL 3H-P2.5

3A-P2.1

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

3C-P2.1

3H-P2.3 3A-P2.2

3H-P2.4

Approved as Noted

3C-P2.2

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

P2 Parking Floor 2 Scale: 1:750

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

P2 Parking Floor

SECTION PAGE No.

8 Locations and Messages

GC.5

SHEET NO.

10.05


LOCATION

MESSAGE

AG : Stair ID (Garage)

3A-P2.1

Stair ID (Garage)

3A-P2.2

Stair ID (Garage)

3C-P2.1

CLIENT REMARKS

LOCATION

MESSAGE

Total Qty: 2

3E-P2.2

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Evac/In Case of Fire (Garage)

STAIR 3-2

STAIR 3-4

CG : Egress Direction (Garage)

Egress Direction (Garage)

DESIGNER NOTES

Total Qty: 2

STAIR 3-2 ROOF ACCESS

3H-P2.1

MAINTENANCE

3H-P2.2

ELEVATOR LOBBY WEST

Room ID (Garage)

3H-P2.3

Room ID (Garage)

3H-P2.4

3E-P2.1

Evac/In Case of Fire (Garage)

Room ID (Garage)

STAIR 3-4 ROOF ACCESS

3H-P2.5

P2 LEVEL P2

Room ID (Garage)

LEVELS P2-13 EXIT UP TO LEVEL 1 [UP ARROW]

Room ID (Garage)

EG : Evac/In Case of Fire (Garage)

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

GARAGE CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3H-P2.6

3H-P2.7

Total Qty: 2

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

HG : Room ID (Garage)

Room ID (Garage)

LEVELS P2-13 EXIT UP TO LEVEL 1 [UP ARROW]

Egress Direction (Garage)

CLIENT REMARKS

[EVAC MAP HOLDER]

P2 LEVEL P2

3C-P2.2

DESIGNER NOTES

Room ID (Garage)

Total Qty: 7

DOCUMENT NAME / SUBMITTAL DATE

DRY PIPE VALVE ROOM

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations must be site Parking Garage - Code - Floor P2 checked

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

RESIDENT STORAGE

APPROVED

Approved as Noted

REVISE AND RESUBMIT

RESIDENT STORAGE

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

ELEVATOR LOBBY EAST ELEVATOR LOBBY EAST

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

Install with vinyl backer.

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

P2 Parking Floor

8 Locations PAGE No. and Messages

GC.6

10.06


11

Buildings 2 and 3 Wayfinding Sign Locations


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

HOLD 2P-1.02 BIKE STORAGE

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

CW

DOCUMENT NAME / SUBMITTAL DATE

3P-1.04 3Mb-1.15

3Mb-1.13

3Ma-1.11

3N-1.08 3Ma-1.10

3N-1.09 3N-1.10 3P-1.03

3N-1.05

BIKE STORAGE

2N-1.03

B3 B

3Mb -1.07

3Mb-1.12

B3 A

2N-1.01 2Mb-1.03

3Mb -1.17

B2

2N-1.02 2Mb-1.02

3N-1.06

3Ma-1.08

04.21.2021

Buildings 2 and 3 - Wayfinding - Ground Floor CLIENT APPROVAL

JH

DRAWN BY

CLIENTApproved REQUIRED APPROVAL

2P-1.01

3Ma -1.09

3N-1.07

2Ma-1.01

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3Mb-1.04

2N-1.04

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

1 Ground Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Ground Floor

SECTION PAGE No.

8 Locations and Messages

IW.1

SHEET NO.

11.01


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

HOLD

2N-2.01

2P-2.02

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

CW

2N-2.02

DOCUMENT NAME / SUBMITTAL DATE 3P-2.04 3Mb-2.08a 3Mb-2.08b

3P-2.03

B3 B

2N-2.03

3Ma-2.07

3Ma-2.10

B3 A

3Ma-2.09 2Mb-2.04

2N-2.09

B2

Buildings 2 and 3 - Wayfinding - Second Floor CLIENT APPROVAL

JH

DRAWN BY

SUBMITTAL: DATE:

Not Approved

2P-2.05 2Mb-2.02

04.21.2021

CLIENTApproved REQUIRED APPROVAL

2N-2.08

2P-2.01

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

2Mb-2.03

REVIEWED BY:

2Mb-2.01

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

3Ma-2.06 3Mb-2.05

2N-2.04

HOLD

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

2N-2.05

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

2 Second Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Second Floor

SECTION PAGE No.

8 Locations and Messages

IW.5

SHEET NO.

11.02


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2N-3.01

2P-3.02

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

CW

2N-3.02

HOLD 3P-3.04 3Mb-3.02a 3Mb-3.02b 3P-3.03

B3 B 3Ma-3.01

3Ma-3.04

B3 A

3Ma-3.03

2N-3.03

2N-3.08

2P-3.01 2N-3.09

B2

DOCUMENT NAME / SUBMITTAL DATE NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

04.21.2021

Buildings 2 and 3 - Wayfinding - Third Floor CLIENT APPROVAL

JH

DRAWN BY

CLIENTApproved REQUIRED APPROVAL SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

2N-3.04

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

2N-3.05

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3 Third Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Third Floor

SECTION PAGE No.

8 Locations and Messages

IW.8

SHEET NO.

11.03


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE 04.21.2021

3Mb-4.02a

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3Mb-4.02b

Buildings 2 and 3 - Wayfinding - Fourth Floor CLIENT APPROVAL

JH

3P-4.03

3P-4.02

2P-4.01

B3 B

FACILITIES

CLIENTApproved REQUIRED APPROVAL

3Ma-4.01

3Ma-4.04

B3 A

3Ma-4.03

DRAWN BY

2Mb-4.05a 2Mb-4.05b

B2

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

4 Fourth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Fourth Floor

SECTION PAGE No.

8 Locations and Messages

IW.10

SHEET NO.

11.04


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE 04.21.2021

3Mb-5.02a

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3Mb-5.02b

Buildings 2 and 3 - Wayfinding - Fifth Floor CLIENT APPROVAL

JH

3P-5.03

3P-5.02

2P-5.01

B3 B

CLIENTApproved REQUIRED APPROVAL

3Ma-5.01

3Ma-5.04

B3 A

3Ma-5.03

DRAWN BY

2Mb-5.05a 2Mb-5.05b

B2

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

5 Fifth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Fifth Floor

SECTION PAGE No.

8 Locations and Messages

IW.12

SHEET NO.

11.05


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE 04.21.2021

3Mb-6.02a

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3Mb-6.02b

Buildings 2 and 3 - Wayfinding - Sixth Floor CLIENT APPROVAL

JH

3P-6.03

3P-6.02

2P-6.01

B3 B

CLIENTApproved REQUIRED APPROVAL

3Ma-6.01

3Ma-6.04

B3 A

3Ma-6.03

DRAWN BY

2Mb-6.05a 2Mb-6.05b

B2

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

6 Sixth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Sixth Floor

SECTION PAGE No.

8 Locations and Messages

IW.14

SHEET NO.

11.06


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE 04.21.2021

3Mb-7.02a

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3Mb-7.02b

Buildings 2 and 3 - Wayfinding - Seventh Floor CLIENT APPROVAL

JH

3P-7.03

3P-7.02

2P-7.01

B3 B

CLIENTApproved REQUIRED APPROVAL

3Ma-7.01

3Ma-7.04

B3 A

3Ma-7.03

DRAWN BY

2Mb-7.05a 2Mb-7.05b

B2

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

7 Seventh Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Seventh Floor

SECTION PAGE No.

8 Locations and Messages

IW.16

SHEET NO.

11.07


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE 04.21.2021

3Mb-8.02a

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3Mb-8.02b

Buildings 2 and 3 - Wayfinding - Eighth Floor CLIENT APPROVAL

JH

3P-8.03

3P-8.02

2P-8.01

B3 B

CLIENTApproved REQUIRED APPROVAL

3Ma-8.01

3Ma-8.04

B3 A

3Ma-8.03

DRAWN BY

2Mb-8.05a 2Mb-8.05b

B2

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

8 Eighth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Eighth Floor

SECTION PAGE No.

8 Locations and Messages

IW.18

SHEET NO.

11.08


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE 04.21.2021

3Mb-9.02a

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3Mb-9.02b

Buildings 2 and 3 - Wayfinding - Ninth Floor CLIENT APPROVAL

JH

3P-9.03

3P-9.02

2P-9.01

B3 B

CLIENTApproved REQUIRED APPROVAL

3Ma-9.01

3Ma-9.04

B3 A

3Ma-9.03

DRAWN BY

2Mb-9.05a 2Mb-9.05b

B2

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

9 Ninth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Ninth Floor

SECTION PAGE No.

8 Locations and Messages

IW.20

SHEET NO.

11.09


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE 04.21.2021

3Mb-10.02a

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3Mb-10.02b

Buildings 2 and 3 - Wayfinding - Tenth Floor CLIENT APPROVAL

JH

3P-10.03

3P-10.02

2P-10.01

B3 B

CLIENTApproved REQUIRED APPROVAL

3Ma-10.01

3Ma-10.04

B3 A

3Ma-10.03

DRAWN BY

2Mb-10.05a 2Mb-10.05b

B2

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

10 Tenth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Tenth Floor

SECTION PAGE No.

8 Locations and Messages

IW.22

SHEET NO.

11.10


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE 04.21.2021

3Mb-11.02a

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3Mb-11.02b

Buildings 2 and 3 - Wayfinding - Eleventh Floor CLIENT APPROVAL

JH

3P-11.03

3P-11.02

2P-11.01

B3 B

CLIENTApproved REQUIRED APPROVAL

3Ma-11.01

3Ma-11.04

B3 A

3Ma-11.03

DRAWN BY

2Mb-11.05a 2Mb-11.05b

B2

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

11 Eleventh Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Eleventh Floor

SECTION PAGE No.

8 Locations and Messages

IW.24

SHEET NO.

11.11


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE 04.21.2021

3Mb-12.02a

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3Mb-12.02b

Buildings 2 and 3 - Wayfinding - Twelfth Floor CLIENT APPROVAL

JH

3P-12.03

3P-12.02

2P-12.01

B3 B

CLIENTApproved REQUIRED APPROVAL

3Ma-12.01

3Ma-12.04

B3 A

3Ma-12.03

DRAWN BY

2Mb-12.05a 2Mb-12.05b

B2

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

12 Twelfth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Twelfth Floor

SECTION PAGE No.

8 Locations and Messages

IW.26

SHEET NO.

11.12


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

3P-13.02 3Mb-13.02a 3Mb-13.02b

3P-13.01

B3 A

DRAWN BY

Buildings 2 and 3 - Wayfinding - Thirteenth Floor JH CLIENT APPROVAL

B3 B

CLIENTApproved REQUIRED APPROVAL

3Ma-13.01

3Ma-13.04

04.21.2021

3Ma-13.03

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

OPEN TO BELOW

Approved as Noted

APPROVED

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

13 Thirteenth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Thirteenth Floor

SECTION PAGE No.

8 Locations and Messages

IW.28

SHEET NO.

11.13


WAYFINDING SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2Mb-14.10 3Mb-14.09

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

3N-14.06

DOCUMENT NAME / SUBMITTAL DATE 3N-14.01 3N-14.04

3P-14.01

3N-14.02 3P-14.02

3Mb-14.01

3Mb-14.05 2N-14.09

2P-14.03

3Mb-14.02 2N-14.03

2Mb-14.13

3N-14.08

04.21.2021

Buildings 2 and 3 - Wayfinding - Rooftop Floor CLIENT APPROVAL

JH

DRAWN BY

CLIENTApproved REQUIRED APPROVAL SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

3N-14.07

3N-14.05

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

APPROVED

2N-14.10

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

R Roof Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Roof

SECTION PAGE No.

8 Locations and Messages

IW.30

SHEET NO.

11.14


12

Buildings 2 and 3 Code Sign Locations and Messages


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-1.27 3D-1.1 3C-1.1 3A-1.2 3H-1.2

3H-1.1

3D-1.25 3A-1.3

3H-1.3

3E-1.1

3J-1.1

3J-1.37

3D-1.12 3D-1.13 3D-1.2

3A-1.7

BIKE STORAGE

3L-1.13 3L-1.15

2D-1.19

3J-1.10 3D-1.4

3E-1.3

3K-1.2

2J-1.17

2J-1.38

3J-1.4 3E-1.2

3G-1.1 3J-1.7

3J-1.12 3J-1.13

2J-1.20

2D-1.18 2J-1.21

2G-1.3

3K-1.9

3A-1.6 3K-1.8 3K-1.6

3D-1.24

3J-1.36

2J-1.23

3K-1.7 3K-1.5 3K-1.4

2G-1.4 2H-1.5

2K-1.12

2J-1.34

3G-1.2

3D-1.10 3D-1.9

3L-1.16

2G-1.5 2D-1.22 2J-1.29 2F-1.5 2J-1.35

Approved as Noted

2J-1.33

APPROVED

2J-1.32

REVISE AND RESUBMIT

2F-1.6

2J-1.25 2J-1.26 2J-1.27

2G-1.6

2J-1.28 2D-1.14 2D-1.30

2D-1.23

JH

DRAWN BY

Not Approved

2J-1.31

2C-1.6

Buildings 2 and 3 - Code - Ground Floor CLIENT APPROVAL

REVIEWED BY:

2K-1.13

2J-1.30

3D-1.8

04.21.2021

SUBMITTAL: DATE:

2H-1.6

2H-1.8 2H-1.7

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

2D-1.21 2K-1.10 2J-1.24

2D-1.20 2K-1.11

3A-1.8 3C-1.4

3A-1.9

3D-1.7

2E-1.5

2F-1.4 3J-1.15

3J-1.14 3K-1.1

3D-1.26

3L-1.17

DOCUMENT NAME / SUBMITTAL DATE

2J-1.19

2F-1.3

3F-1.2

3F-1.1

3A-1.5 3D-1.3 3D-1.6

3L-1.14

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2J-1.22

3C-1.2

3L-1.12

2J-1.18

BIKE STORAGE

3K-1.3 3J-1.11

2D-1.29 2C-1.5

2A-1.12

3D-1.11

2A-1.11

2D-1.28

3D-1.27

3C-1.3

3J-1.9

3D-1.5

3J-1.6 3A-1.4

2J-1.16

3L-1.33

3J-1.3

3L-1.11

2H-1.4

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2A-1.10

2D-1.17 2E-1.4

3L-1.31

3J-1.2

3J-1.5

2D-1.15 2K-1.14

3L-1.28

3L-1.29

3J-1.8 3L-1.9

2D-1.16

3L-1.26

3A-1.1

2A-1.13

2A-1.14

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

1 Ground Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Ground Floor

SECTION PAGE No.

8 Locations and Messages

IC.1

SHEET NO.

12.01


LOCATION

MESSAGE

DESIGNER NOTES

2A : Stair ID

2A-1.10 Stair ID

2A-1.11 Stair ID

CLIENT REMARKS

LOCATION

Total Qty: 5

2D : Exit ID

STAIR 2-1

2D-1.14 Exit ID

STAIR 2-1

2D-1.15 Exit ID

MESSAGE

DESIGNER NOTES

CLIENT REMARKS

Total Qty: 13

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

EXIT

EXIT

INTERIOR CODE SIGNAGE

FOH

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

2A-1.12

STAIR 2-1

2D-1.16

EXIT

2A-1.13

STAIR 2-2

2D-1.17

EXIT

Stair ID

Stair ID

2A-1.14 Stair ID

STAIR 2-2

Exit ID

Exit ID

2D-1.18

Exterior Grade

Exit ID

EXIT

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

FOH

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Ground Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

2C : Egress Direction

2C-1.5

Egress Direction

STAIR 2-1 ROOF ACCESS 1 LEVEL 1

Total Qty: 2

2D-1.19 Exit ID

REVIEWED BY:

2D-1.20 Exit ID

EXIT

FOH

2D-1.21

EXIT

2D-1.22

EXIT

FOH

STAIR 2-2 ROOF ACCESS

2D-1.23

EXIT

FOH

1 LEVEL 1

2D-1.28

FIRE EXIT ROUTE

LEVELS 1-12 EXIT THIS LEVEL [STAR ICON]

2D-1.29

FIRE EXIT ROUTE

Exit ID

Exit ID

Exit ID

Exit ID

2D-1.30 Exit ID

APPROVED

Approved as Noted

REVISE AND RESUBMIT

FOH

LEVELS P1-12 EXIT THIS LEVEL [STAR ICON]

Egress Direction

SUBMITTAL: DATE:

Not Approved

Exit ID

2C-1.6

Approved

EXIT

FIRE EXIT ROUTE

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Ground Floor

8 Locations PAGE No. and Messages

IC.2

12.02


LOCATION

MESSAGE

DESIGNER NOTES

2E : Evac/In Case of Fire

2E-1.4

Evac/In Case of Fire

CLIENT REMARKS

Total Qty: 2

Evac/In Case of Fire

2G-1.5

MAX OCCUPANCY XX

B2 Fitness Studio 2

MAX OCCUPANCY XX

B2 Fitness Center

Max Occupancy

2H-1.4

TRASH ROOM

2H-1.5

HOUSEKEEPING

Room ID (BOH)

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Room ID (BOH)

2H-1.6

Room ID (BOH)

Restroom ID

Restroom ID

2F-1.6

Restroom ID

2H-1.7

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

Room ID (BOH)

Max Occupancy

2G-1.4

Max Occupancy

Total Qty: 5

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Room is not named on plan. Client to confirm room designation.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Ground Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

STORAGE

SUBMITTAL: DATE:

Room is not named on plan. Client to confirm room designation.

REVIEWED BY:

Not Approved

APPROVED

2H-1.8

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

Approved as Noted

LEASING OFFICE

REVISE AND RESUBMIT

LOADING DOCK

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

BIKE STORAGE

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

2J : Room ID (FOH)

2J-1.16

[MEN RESTROOM/ ACCESSIBLE SYMBOL] MEN'S LOCKERS

2J-1.17

Room ID (FOH)

[WOMEN RESTROOM/ ACCESSIBLE SYMBOL] WOMEN'S LOCKERS

2J-1.18

Room ID (FOH)

2G : Max Occupancy

2G-1.3

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

Approved

Room ID (FOH)

2F-1.5

INTERIOR CODE SIGNAGE

Total Qty: 4

Room ID (BOH)

2F-1.4

STORAGE

CLIENT REMARKS

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

2H : Room ID (BOH)

2F : Restroom ID

Restroom ID

DESIGNER NOTES

2G-1.6

[EVAC MAP HOLDER]

2F-1.3

MESSAGE

Max Occupancy

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

2E-1.5

LOCATION

Total Qty: 4

MAX OCCUPANCY XX

B2 Lobby

MAX OCCUPANCY XX

B2 Fitness Studio 1

2J-1.19

Room ID (FOH)

2J-1.20

Room ID (FOH)

2J-1.21

Room ID (FOH)

Total Qty: 22

CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

STAFF ONLY

STORAGE

STORAGE

PACKAGE ROOM

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

Room is not named on plan. Client to confirm room designation.

Room is not named on plan. Client to confirm room designation.

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Ground Floor

8 Locations PAGE No. and Messages

IC.3

12.03


LOCATION

MESSAGE

DESIGNER NOTES

2J-1.22

STORAGE

Room is not named on plan. Client to confirm room designation.

Room ID (FOH)

CLIENT REMARKS

LOCATION

MESSAGE

DESIGNER NOTES

2J-1.35

FITNESS STUDIO 2

Install with vinyl backer

Room ID (FOH)

2J-1.23

PACKAGE ROOM

2J-1.36

CATERING KITCHEN

2J-1.24

STAFF ONLY

2J-1.38

BIKE STORAGE

2J-1.25

STORAGE

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

Room is not named on plan. Client to confirm room designation.

Ammenity ID

2J-1.26

Room ID (FOH)

STORAGE

Room is not named on plan. Client to confirm room designation.

2K-1.11

Ammenity ID

2J-1.27

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

2K-1.12 STORAGE

Room ID (FOH)

2J-1.31

2K-1.13

2K-1.14

STORAGE

2J-1.34

Room ID (FOH)

MAIL ROOM

3A-1.1 Stair ID

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Ground Floor

DRAWN BY JH

SUBMITTAL: DATE: REVIEWED BY:

APPROVED

LEASING OFFICE

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

OFFICE LOBBY

CONTENTS:

Total Qty: 9

STAIR 3-1

Exterior Grade

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

Room is not named on plan. Client to confirm room designation.

3A-1.2

STAIR 3-1

3A-1.3

STAIR 3-1

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

Stair ID

3A-1.4 Install with vinyl backer

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

Stair ID

STAFF ONLY

FITNESS STUDIO 1

Design-Build Package - POST FINAL REVISED

Approved

FITNESS CENTER

3A : Stair ID

2J-1.32

Room ID (FOH)

DOCUMENT NAME / SUBMITTAL DATE

MASSAGE

TO LOCKERS MASSAGE & SAUNA

2J-1.33

MAIL ROOM

SAUNA

Room ID (FOH)

Room ID (FOH)

Total Qty: 5

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

Not Approved

Room is not named on plan. Client to confirm room designation.

Ammenity ID

2J-1.30

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

Ammenity ID

2J-1.29

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OFFICE Ammenity ID

2J-1.28

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

2K : Ammenity ID

2K-1.10

CLIENT REMARKS

Stair ID

3A-1.5 Stair ID

STAIR 3-2

STAIR 3-2

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Ground Floor

8 Locations PAGE No. and Messages

IC.4

12.04


LOCATION

MESSAGE

DESIGNER NOTES

3A-1.6

STAIR 3-2

Exterior Grade

Stair ID

CLIENT REMARKS

LOCATION

MESSAGE

3C-1.3

STAIR 3-3 ROOF ACCESS

Egress Direction

3A-1.7

STAIR 3-3

1 LEVEL 1

3A-1.8

STAIR 3-4

3A-1.9

STAIR 3-4

LEVELS 1-13 EXIT THIS LEVEL [STAR ICON]

Stair ID

Stair ID

Stair ID

3C-1.4

Egress Direction

3C : Egress Direction

3C-1.1

Egress Direction

Total Qty: 4

1 LEVEL 1

1 LEVEL 1

LEVELS P2-13 EXIT THIS LEVEL [STAR ICON]

Egress Direction

STAIR 3-2 ROOF ACCESS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Ground Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Total Qty: 17

3D-1.1

EXIT

3D-1.2

EXIT

3D-1.3

EXIT

3D-1.4

EXIT

Exit ID

LEVELS P2-13 EXIT THIS LEVEL [STAR ICON]

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3D : Exit ID

Exit ID

1 LEVEL 1

INTERIOR CODE SIGNAGE

Approved as Noted

Exit ID

3C-1.2

CLIENT REMARKS

STAIR 3-4 ROOF ACCESS

STAIR 3-1 ROOF ACCESS

LEVELS 1-13 EXIT THIS LEVEL [STAR ICON]

DESIGNER NOTES

Exit ID

3D-1.5 Exit ID

3D-1.6 Exit ID

EXIT

EXIT

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

FOH

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

FOH

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

FOH

FOH

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Ground Floor

8 Locations PAGE No. and Messages

IC.5

12.05


LOCATION

MESSAGE

DESIGNER NOTES

3D-1.7

EXIT

FOH

Exit ID

3D-1.8

EXIT

FOH

3D-1.9

EXIT

FOH

Exit ID

Exit ID

3D-1.10 Exit ID

3D-1.11 Exit ID

3D-1.12 Exit ID

CLIENT REMARKS

LOCATION

MESSAGE

3E-1.2

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Evac/In Case of Fire

EXIT

Evac/In Case of Fire

FOH

FOH

Exit ID

Exit ID

3D-1.25 Exit ID

FIRE EXIT ROUTE

3F-1.1

EXIT

Exit ID

3D-1.27 Exit ID

EXIT

Restroom ID

FOH

FIRE EXIT ROUTE

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 2

[WOMEN RESTROOM/ ACCESSIBLE SYMBOL] WOMEN

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Ground Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

[EVAC MAP HOLDER]

REVISE AND RESUBMIT

Total Qty: 3

Total Qty: 2

MAX OCCUPANCY XX

B3 Lobby

3G-1.2

MAX OCCUPANCY XX

B3 Resident Lounge

3H-1.1

Room ID (BOH)

3H-1.2

Room ID (BOH)

LOADING DOCK

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

3G-1.1

Max Occupancy

FIRE EXIT ROUTE

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Approved as Noted

[MEN RESTROOM/ ACCESSIBLE SYMBOL] MEN

3G : Max Occupancy

FIRE EXIT ROUTE

3E : Evac/In Case of Fire

Evac/In Case of Fire

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

3H : Room ID (BOH)

3E-1.1

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

APPROVED

Max Occupancy

3D-1.26

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3F : Restroom ID

3F-1.2 3D-1.24

INTERIOR CODE SIGNAGE

[EVAC MAP HOLDER]

Restroom ID

3D-1.13

CLIENT REMARKS

[EVAC MAP HOLDER] 3E-1.3

EXIT

DESIGNER NOTES

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

Total Qty: 3

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

TRASH ROOM

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3H-1.3

Room ID (BOH)

VRF ROOM

SHEET NO.

Ground Floor

8 Locations PAGE No. and Messages

IC.6

12.06


LOCATION

MESSAGE

DESIGNER NOTES

3J : Room ID (FOH)

3J-1.1

Room ID (FOH)

3J-1.2

Room ID (FOH)

3J-1.3

Room ID (FOH)

CLIENT REMARKS

Total Qty: 16

LOCATION

MESSAGE

DESIGNER NOTES

3J-1.14

HOUSEKEEPING

Room is not named on plan. Client to confirm room designation.

Room ID (FOH)

STAFF ONLY

3J-1.15

CATERING KITCHEN

3J-1.37

BIKE STORAGE

Room ID (FOH)

STORAGE

Room ID (FOH)

TO LOBBY

Room ID (FOH)

3J-1.5

Room ID (FOH)

BIKE STORAGE

3K-1.1

Ammenity ID

GAS METER ROOM

3K-1.2

Ammenity ID

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

3K : Ammenity ID

3J-1.4

CLIENT REMARKS

Total Qty: 9

MAIL ROOM

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

MAIL ROOM

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Ground Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3J-1.6

Room ID (FOH)

ELECTRICAL ROOM

3K-1.3

Ammenity ID

PET SPA

Approved

Install with vinyl bac3Ker

SUBMITTAL: DATE: REVIEWED BY:

Not Approved

3J-1.7

Room ID (FOH)

STORAGE

3K-1.4

Ammenity ID

RESIDENT LOUNGE

3J-1.8

FIRE CONTROL ROOM

3K-1.5

RESIDENT LOUNGE

Install with vinyl bac3Ker

3J-1.9

ELECTRICAL ROOM

3K-1.6

MEETING ROOM 1

Install with vinyl bac3Ker

3J-1.10

GAS METER ROOM

3K-1.7

MEETING ROOM 2

Install with vinyl bac3Ker

3J-1.11

HOUSEKEEPING

Room is not named on plan. Client to confirm room designation.

3K-1.8

BUSINESS CENTER

3J-1.12

STORAGE

Room is not named on plan. Client to confirm room designation.

3K-1.9

BUSINESS CENTER

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

3J-1.13

Room ID (FOH)

PACKAGE ROOM

Ammenity ID

Ammenity ID

Ammenity ID

Ammenity ID

Ammenity ID

3L : Apartment ID

3L-1.9

Apartment ID

APPROVED

Install with vinyl bac3Ker

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Total Qty: 14

1-09

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Ground Floor

8 Locations PAGE No. and Messages

IC.7

12.07


LOCATION

MESSAGE

3L-1.11

1-11

Apartment ID

3L-1.12

1-12

3L-1.13

1-13

3L-1.14

1-14

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-1.15

Apartment ID

3L-1.16

Apartment ID

1-15

1-16

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Ground Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-1.17

Apartment ID

1-17

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-1.26

Apartment ID

1-26

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

3L-1.27

Apartment ID

3L-1.28

Apartment ID

3L-1.29

Apartment ID

3L-1.31

Apartment ID

1-27

1-28

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

1-29

1-31

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-1.33

Apartment ID

1-33

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

8 Locations PAGE No. and Messages

SHEET NO.

IC.8

12.08


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-2.2

3L-2.1

3L-2.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-2.4 3L-2.27

3L-2.26

3L-2.6

3L-2.5 3A-2.1

3C-2.1

3L-2.28

3L-2.29

3E-2.1 3L-2.8

3A-2.3

3L-2.10

3J-2.4 3L-2.18 3J-2.5 3L-2.11

3L-2.20

3L-2.15

3L-2.22

3J-2.8

2F-2.1

2J-2.10

2F-2.2

3L-2.24

3L-2.23

3L-2.25

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

04.21.2021

Buildings 2 and 3 - Code - Second Floor CLIENT APPROVAL

JH

SUBMITTAL: DATE:

3J-2.6

Not Approved

2E-2.6

3L-2.36

REVIEWED BY:

3L-2.35

Approved as Noted

3C-2.2 3L-2.12 3L-2.14

APPROVED

3L-2.37

3C-2.4 3A-2.4

2J-2.11

3L-2.38

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

3L-2.39 3L-2.17

DRAWN BY

CLIENTApproved REQUIRED APPROVAL

2E-2.5

3L-2.34 3L-2.21

DOCUMENT NAME / SUBMITTAL DATE

2A-2.5

3E-2.3

3J-2.7

3E-2.2

3L-2.19

3L-2.13

2J-2.9 2C-2.5

3L-2.33

3J-2.3

3A-2.2

3C-2.3

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

3L-2.32

3J-2.2 3L-2.9

2E-2.4

3L-2.30

3L-2.31

3J-2.1

3L-2.7

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

3L-2.41 3L-2.16 3L-2.43

3L-2.40 3L-2.42

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

3L-2.45

No.

2J-2.13 2F-2.4 2F-2.5

2A-2.6

2F-2.3 2C-2.6 2J-2.12 2F-2.6

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

2 Second Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Second Floor

SECTION PAGE No.

8 Locations and Messages

IC.9

SHEET NO.

12.09


LOCATION

MESSAGE

2A : Stair ID

2A-2.5 Stair ID

2A-2.6 Stair ID

Egress Direction

CLIENT REMARKS

Total Qty: 2

LOCATION

MESSAGE

2E-2.5

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Evac/In Case of Fire

STAIR 2-1

STAIR 2-2

2C : Egress Direction

2C-2.5

DESIGNER NOTES

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

[EVAC MAP HOLDER] Total Qty: 2

2E-2.6

Evac/In Case of Fire

STAIR 2-1 ROOF ACCESS 2 LEVEL 2

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

DOCUMENT NAME / SUBMITTAL DATE

[EVAC MAP HOLDER] 2F : Restroom ID

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2F-2.1

Restroom ID

Total Qty: 6

[WOMEN RESTROOM/ ACCESSIBLE SYMBOL] WOMEN

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Second Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

2C-2.6

Egress Direction

STAIR 2-2 ROOF ACCESS

2F-2.2

Restroom ID

2 LEVEL 2

2F-2.3

Restroom ID

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 2E : Evac/In Case of Fire

2E-2.4

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

2F-2.4

[UNISEX RESTROOM SYMBOL] RESTROOM

Confirm if restroom is accessible.

2F-2.5

[UNISEX RESTROOM SYMBOL] RESTROOM

Confirm if restroom is accessible.

[UNISEX RESTROOM SYMBOL] RESTROOM

Confirm if restroom is accessible.

Restroom ID

Total Qty: 3

Restroom ID

2F-2.6 [EVAC MAP HOLDER]

Approved as Noted

[MEN RESTROOM/ ACCESSIBLE SYMBOL] MEN

Restroom ID

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Second Floor

8 Locations PAGE No. and Messages

IC.10

12.10


LOCATION

MESSAGE

DESIGNER NOTES

2J : Room ID (FOH)

2J-2.9

Room ID (FOH)

2J-2.10

Room ID (FOH)

STORAGE

ELEC/ TELECOM ROOM

2J-2.12

STORAGE

Room ID (FOH)

2J-2.13

Room ID (FOH)

HOUSEKEEPING

3A : Stair ID

3A-2.1 Stair ID

3A-2.2 Stair ID

Total Qty: 5

ELECTRICAL ROOM

2J-2.11

Room ID (FOH)

CLIENT REMARKS

LOCATION

3C : Egress Direction

3C-2.1

Egress Direction

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] Room is not named on plan. Client to confirm room designation.

3C-2.2

Egress Direction

Room is not named on plan. Client to confirm room designation.

Stair ID

3A-2.4 Stair ID

DESIGNER NOTES

CLIENT REMARKS

Total Qty: 4

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Second Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

STAIR 3-1

STAIR 3-2

STAIR 3-4

STAIR 3-2 ROOF ACCESS 2 LEVEL 2

Total Qty: 4

STAIR 3-3

STAIR 3-1 ROOF ACCESS 2 LEVEL 2

Room is not named on plan. Client to confirm room designation.

3C-2.3 3A-2.3

MESSAGE

Egress Direction

STAIR 3-3 ROOF ACCESS 2 LEVEL 2 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Second Floor

8 Locations PAGE No. and Messages

IC.11

12.11


LOCATION

MESSAGE

3C-2.4

Egress Direction

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

STAIR 3-4 ROOF ACCESS

3J-2.3

ELECTRICAL ROOM

2 LEVEL 2

3J-2.4

GAS METER ROOM

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

3J-2.5

ELECTRICAL ROOM

3J-2.6

GAS METER ROOM

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

3E : Evac/In Case of Fire

3E-2.1

Evac/In Case of Fire

Total Qty: 3

3J-2.7

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Evac/In Case of Fire

3J-2.8

HOUSEKEEPING

Room ID (FOH)

3L : Apartment ID

3L-2.1

Apartment ID

3L-2.2

Apartment ID

Room ID (FOH)

3J-2.2

Room ID (FOH)

TRASH

ELECTRICAL ROOM

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Second Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Room is not named on plan. Client to confirm room designation.

Approved SUBMITTAL: DATE: REVIEWED BY:

APPROVED

2-01

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

2-02

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

Apartment ID

2-03

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

3L-2.4

2-04

3L-2.5

2-05

Apartment ID

[EVAC MAP HOLDER]

3J-2.1

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

CONTENTS:

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

3J : Room ID (FOH)

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

Approved as Noted

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

3L-2.3 Evac/In Case of Fire

INTERIOR CODE SIGNAGE

Total Qty: 44

[EVAC MAP HOLDER] 3E-2.3

CLIENT REMARKS

Not Approved

[EVAC MAP HOLDER] 3E-2.2

Room ID (FOH)

ELECTRICAL ROOM

DESIGNER NOTES

Apartment ID

Total Qty: 8

3L-2.6

Apartment ID

3L-2.7

Apartment ID

2-06

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

2-07

MESSAGES SECTION

SHEET NO.

Second Floor

8 Locations PAGE No. and Messages

IC.12

12.12


LOCATION

MESSAGE

3L-2.8

2-08

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-2.22

2-22

Apartment ID

3L-2.9

2-09

3L-2.23

2-23

3L-2.10

2-10

3L-2.24

2-24

3L-2.11

2-11

3L-2.25

2-25

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-2.12

Apartment ID

3L-2.13

Apartment ID

2-12

2-13

3L-2.26

Apartment ID

3L-2.27

Apartment ID

2-26

2-27

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Second Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-2.14

Apartment ID

2-14

3L-2.28

Apartment ID

REVIEWED BY:

Not Approved

2-28

APPROVED

Approved as Noted

3L-2.15

Apartment ID

2-15

3L-2.29

Apartment ID

REVISE AND RESUBMIT

2-29

2-30

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

2-31

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-2.16

Apartment ID

3L-2.17

Apartment ID

3L-2.18

Apartment ID

3L-2.19

Apartment ID

2-16

2-17

2-18

2-19

3L-2.30

Apartment ID

3L-2.31

Apartment ID

3L-2.32

Apartment ID

3L-2.33

Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

2-32

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

2-33

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-2.20

Apartment ID

2-20

3L-2.34

Apartment ID

2-34

Door is not indicated on the plan.

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-2.21

Apartment ID

2-21

3L-2.35

Apartment ID

2-35

SHEET NO.

Second Floor

8 Locations PAGE No. and Messages

IC.13

12.13


LOCATION

MESSAGE

3L-2.36

2-36

Apartment ID

3L-2.37

2-37

3L-2.38

2-38

3L-2.39

2-39

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-2.40

Apartment ID

3L-2.41

Apartment ID

2-40

2-41

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Second Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-2.42

Apartment ID

REVIEWED BY:

Not Approved

2-42

APPROVED

Approved as Noted

3L-2.43

Apartment ID

REVISE AND RESUBMIT

2-43

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

3L-2.45

Apartment ID

2-45

There is no T-44 indicated on the plan.

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Second Floor

8 Locations PAGE No. and Messages

IC.14

12.14


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-3.2

3L-3.1

3L-3.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-3.4 3L-3.27

3L-3.26

3L-3.6

3L-3.5 3A-3.1

3C-3.1

3L-3.28

3L-3.29

3E-3.1 3J-3.1

3L-3.7

3A-3.3

3L-3.10 3L-3.33

3J-3.3 3J-3.4 3L-3.18 3J-3.5

3L-3.11

3L-3.20

3L-3.13

3L-3.15

2J-3.9

3L-3.22

2A-3.5 2F-3.1

3E-3.3

3J-3.7

2J-3.10

2F-3.2

3L-3.24

3L-3.23

3L-3.25

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

04.21.2021

Buildings 2 and 3 - Code - Third Floor CLIENT APPROVAL

JH

SUBMITTAL: DATE:

3J-3.6

Not Approved

3L-3.36

REVIEWED BY:

3L-3.35

Approved as Noted

3C-3.2 3L-3.12 3L-3.14

APPROVED

3C-3.4

3L-3.37 3A-3.4

2J-3.11

3L-3.38

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

3L-3.39 3L-3.17

DRAWN BY

CLIENTApproved REQUIRED APPROVAL

2E-3.5

3L-3.34 3L-3.21

DOCUMENT NAME / SUBMITTAL DATE

2C-3.5 3J-3.8

3E-3.2

3L-3.19 3A-3.2

3C-3.3

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

3L-3.32

3J-3.2 3L-3.9

2E-3.4

3L-3.30

3L-3.31

3L-3.8

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

3L-3.41 3L-3.16 3L-3.43

3L-3.40 3L-3.42

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

3L-3.45

2A-3.6 2C-3.6

2J-3.13

2F-3.3 2F-3.5

2F-3.4 2J-3.12 2F-3.6

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3 Third Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Third Floor

SECTION PAGE No.

8 Locations and Messages

IC.15

SHEET NO.

12.15


LOCATION

MESSAGE

2A : Stair ID

2A-3.5 Stair ID

2A-3.6 Stair ID

Egress Direction

CLIENT REMARKS

Total Qty: 2

2E-3.5

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Total Qty: 2

Restroom ID

2F-3.2

Restroom ID

2F-3.3

Restroom ID

STAIR 2-2 ROOF ACCESS

2F-3.4

Restroom ID

2F-3.5

Restroom ID

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2F-3.6

Restroom ID

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

Total Qty: 6

[WOMEN RESTROOM/ ACCESSIBLE SYMBOL] WOMEN

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

[MEN RESTROOM/ ACCESSIBLE SYMBOL] MEN

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Third

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved

3 LEVEL 3

2E-3.4

CLIENT REMARKS

INTERIOR CODE SIGNAGE

2F : Restroom ID

2F-3.1

STAIR 2-1 ROOF ACCESS

2E : Evac/In Case of Fire

DESIGNER NOTES

[EVAC MAP HOLDER]

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Egress Direction

MESSAGE

STAIR 2-2

3 LEVEL 3

2C-3.6

LOCATION

Evac/In Case of Fire

STAIR 2-1

2C : Egress Direction

2C-3.5

DESIGNER NOTES

Total Qty: 2

SUBMITTAL: DATE:

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

[UNISEX RESTROOM SYMBOL] RESTROOM

Confirm if restroom is accessible.

[UNISEX RESTROOM SYMBOL] RESTROOM

Confirm if restroom is accessible.

[UNISEX RESTROOM SYMBOL] RESTROOM

Room ID (FOH)

ELECTRICAL ROOM

2J-3.10

STORAGE

Room ID (FOH)

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

Confirm if restroom is accessible.

2J : Room ID (FOH)

2J-3.9

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

Total Qty: 5

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Room is not named on plan. Client to confirm room designation.

MESSAGES SECTION

SHEET NO.

Third Floor

8 Locations PAGE No. and Messages

IC.16

12.16


LOCATION

MESSAGE

2J-3.11

ELEC/ TELECOM ROOM

Room ID (FOH)

2J-3.12

Room ID (FOH)

2J-3.13

Room ID (FOH)

STORAGE

HOUSEKEEPING

DESIGNER NOTES

Stair ID

3A-3.2 Stair ID

LOCATION

MESSAGE

DESIGNER NOTES

3C-3.2

STAIR 3-2 ROOF ACCESS

Door is not indicated on the plan.

Egress Direction

3 LEVEL 3

Room is not named on plan. Client to confirm room designation.

Total Qty: 4

STAIR 3-1

STAIR 3-2

3C-3.3

Door is not indicated on the plan.

Egress Direction

STAIR 3-3 ROOF ACCESS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 Door is not indicated on the plan.

3 LEVEL 3

Door is not indicated on the plan.

CLIENT REMARKS

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Room is not named on plan. Client to confirm room designation.

3A : Stair ID

3A-3.1

CLIENT REMARKS

DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Third

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3A-3.3 Stair ID

3A-3.4 Stair ID

STAIR 3-3

STAIR 3-4

Door is not indicated on the plan.

3C : Egress Direction

3C-3.1

Egress Direction

STAIR 3-1 ROOF ACCESS 3 LEVEL 3 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Total Qty: 4 Door is not indicated on the plan.

REVIEWED BY:

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Door is not indicated on the plan.

3C-3.4

Egress Direction

STAIR 3-4 ROOF ACCESS

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

Door is not indicated on the plan.

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

3 LEVEL 3

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Third Floor

8 Locations PAGE No. and Messages

IC.17

12.17


LOCATION

MESSAGE

DESIGNER NOTES

3E : Evac/In Case of Fire

3E-3.1

Evac/In Case of Fire

CLIENT REMARKS

Total Qty: 3

Evac/In Case of Fire

MESSAGE

DESIGNER NOTES

3J-3.6

GAS METER ROOM

Room is not named on plan. Client to confirm room designation.

Room ID (FOH)

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

3J-3.7

Room ID (FOH)

[EVAC MAP HOLDER] 3E-3.2

LOCATION

3J-3.8

Room ID (FOH)

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Apartment ID

HOUSEKEEPING

3E-3.3

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Apartment ID

3L-3.3

Apartment ID

3L-3.4

3J : Room ID (FOH)

3J-3.2

Room ID (FOH)

3J-3.3

Room ID (FOH)

3J-3.4

Room ID (FOH)

3J-3.5

Room ID (FOH)

TRASH

3-01

Room is not named on plan. Client to confirm room designation.

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

There is a room, but no door. Client to confirm if there is a door that isn’t shown on the plan.

DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Third

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3-03

Not Approved

APPROVED

Approved as Noted

3-04

3-05

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

3-06

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-3.5

Apartment ID

3L-3.6

Apartment ID

3L-3.7

ELECTRICAL ROOM

ELEC/ TELECOM ROOM

3-02

Total Qty: 8

ELECTRICAL ROOM

GAS METER ROOM

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

REVISE AND RESUBMIT

Apartment ID

Room ID (FOH)

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

REVIEWED BY:

[EVAC MAP HOLDER]

3J-3.1

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

Total Qty: 44

[EVAC MAP HOLDER] 3L-3.2

INTERIOR CODE SIGNAGE

ELEC/ TELECOM ROOM

3L : Apartment ID

3L-3.1

CLIENT REMARKS

Apartment ID

Room is not named on plan. Client to confirm room designation.

3L-3.8

Apartment ID

3L-3.9

Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

3-07

3-08

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3-09

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-3.10

Apartment ID

3-10

SHEET NO.

Third Floor

8 Locations PAGE No. and Messages

IC.18

12.18


LOCATION

MESSAGE

3L-3.11

3-11

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-3.25

3-25

Apartment ID

3L-3.12

3-12

3L-3.26

3-26

3L-3.13

3-13

3L-3.27

3-27

3L-3.14

3-14

3L-3.28

3-28

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-3.15

Apartment ID

3L-3.16

Apartment ID

3-15

3-16

3L-3.29

Apartment ID

3L-3.30

Apartment ID

3-29

3-30

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Third

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-3.17

Apartment ID

3-17

3L-3.31

Apartment ID

REVIEWED BY:

Not Approved

3-31

APPROVED

Approved as Noted

3L-3.18

Apartment ID

3-18

3L-3.32

Apartment ID

REVISE AND RESUBMIT

3-32

3-33

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

3-34

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-3.19

Apartment ID

3L-3.20

Apartment ID

3L-3.21

Apartment ID

3L-3.22

Apartment ID

3-19

3-20

3-21

3-22

3L-3.33

Apartment ID

3L-3.34

Apartment ID

3L-3.35

Apartment ID

3L-3.36

Apartment ID

3-35

3-36

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

Door is not indicated on the plan.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-3.23

Apartment ID

3-23

3L-3.37

Apartment ID

3-37

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-3.24

Apartment ID

3-24

3L-3.38

Apartment ID

3-38

SHEET NO.

Third Floor

8 Locations PAGE No. and Messages

IC.19

12.19


LOCATION

MESSAGE

3L-3.39

3-39

Apartment ID

3L-3.40

Apartment ID

3-40

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE

There are 2 doors indicated on the plan. Client to confirm if this is an error.

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

3L-3.41

3-41

3L-3.42

3-42

Apartment ID

Apartment ID

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-3.43

Apartment ID

3L-3.45

Apartment ID

3-43

3-45

There is no T-44 indicated on the plan.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Third

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Third Floor

8 Locations PAGE No. and Messages

IC.20

12.20


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-4.2

3L-4.1

3L-4.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-4.4 3L-4.27

3L-4.26

3L-4.6

3L-4.5

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2L-4.52 3A-4.1

3C-4.1 3E-4.1 3L-4.8

3L-4.33

3J-4.3 3J-4.4 3L-4.18 3J-4.5

3L-4.11

3L-4.20

3A-4.2 3L-4.15

FACILITIES

2L-4.57 3L-4.34 3L-4.21

3L-4.23

3L-4.25

2E-4.4

2K-4.1

3L-4.36

2J-4.14

3L-4.37

2J-4.17

2J-4.16

2L-4.62

2L-4.61

3C-4.4 3A-4.4

2J-4.15

2L-4.59

3L-4.43

2J-4.19 2J-4.20

3L-4.40 3L-4.42 2L-4.65 3L-4.45

JH

DRAWN BY

SUBMITTAL: DATE:

Not Approved

REVIEWED BY:

Approved as Noted

REVISE AND RESUBMIT

2L-4.63

3L-4.16

Buildings 2 and 3 - Code - Fourth Floor CLIENT APPROVAL

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

2L-4.64 3L-4.41

04.21.2021

APPROVED

2J-4.18

3L-4.38

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

2J-4.13

3J-4.6

3L-4.39 3L-4.17

2J-4.12

3L-4.24

3C-4.2

3L-4.14

2J-4.11

2L-4.56

3L-4.35

3L-4.12

2J-4.10

2L-4.55

3E-4.3

3E-4.2

3L-4.19

3L-4.13

3L-4.22

DOCUMENT NAME / SUBMITTAL DATE

2A-4.5 3J-4.8

3J-4.7

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2C-4.5

3C-4.3 3L-4.32

3J-4.2 3L-4.9

2J-4.9

3A-4.3

3L-4.10

2L-4.54

2L-4.53

3L-4.30

3L-4.31

3J-4.1

3L-4.7

2L-4.51

3L-4.28

3L-4.29

2L-4.66

2L-4.67

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

2L-4.68 2A-4.6

2C-4.6

2L-4.70 2L-4.69

2L-4.72

2L-4.71 2L-4.74 2L-4.73

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

4 Fourth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Fourth Floor

SECTION PAGE No.

8 Locations and Messages

IC.21

SHEET NO.

12.21


LOCATION

MESSAGE

2A : Stair ID

2A-4.5 Stair ID

2A-4.6 Stair ID

Egress Direction

CLIENT REMARKS

Total Qty: 2

STAIR 2-1

LOCATION

Room ID (FOH)

2J-4.10

Room ID (FOH)

Total Qty: 2

STORAGE

Room is not named on plan. Client to confirm room designation.

Room is not named on plan. Client to confirm room designation.

Room is not named on plan. Client to confirm room designation.

2J-4.12

OFFICE

Room is not named on plan. Client to confirm room designation.

2J-4.13

Room ID (FOH)

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

TRASH

OFFICE

CLIENT REMARKS

Total Qty: 12

OFFICE

Room ID (FOH)

4 LEVEL 4

DESIGNER NOTES

2J-4.11

Room ID (FOH)

STAIR 2-1 ROOF ACCESS

MESSAGE

2J : Room ID (FOH)

2J-4.9

STAIR 2-2

2C : Egress Direction

2C-4.5

DESIGNER NOTES

Room is not named on plan. Client to confirm room designation. No door is shown on plan.

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site Floor checked Buildings 2 and 3 - must Code be - Fourth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved

2J-4.14

Room ID (FOH)

STORAGE

SUBMITTAL: DATE:

Room is not named on plan. Client to confirm room designation.

REVIEWED BY:

Not Approved

APPROVED

2C-4.6

Egress Direction

Approved as Noted

STAIR 2-2 ROOF ACCESS

2J-4.15

Room ID (FOH)

OFFICE

Room is not named on plan. Client to confirm room designation.

REVISE AND RESUBMIT

Room is not named on plan. Client to confirm room designation.

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

Room is not named on plan. Client to confirm room designation.

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

4 LEVEL 4

2J-4.16

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2J-4.17

2E : Evac/In Case of Fire

2E-4.4

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

Room ID (FOH)

Room ID (FOH)

STORAGE

KITCHEN

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

2J-4.18

Room ID (FOH)

Total Qty: 1

ELEC/ TELECOM ROOM

2J-4.19

ELECTRICAL ROOM

2J-4.20

ELECTRICAL ROOM

Room ID (FOH)

Room ID (FOH)

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Fourth Floor

8 Locations PAGE No. and Messages

IC.22

12.22


LOCATION

MESSAGE

DESIGNER NOTES

2K : Ammenity ID

2K-4.1

Ammenity ID

Total Qty: 1

Apartment ID

2L-4.52

Apartment ID

2L-4.53

Apartment ID

2L-4.54

Apartment ID

Total Qty: 22

4-51

LOCATION

MESSAGE

DESIGNER NOTES

2L-4.65

4-65

No door on plan.

Apartment ID

FACILITIES

2L : Apartment ID

2L-4.51

CLIENT REMARKS

No door on plan.

2L-4.66

4-66

No door on plan.

2L-4.67

4-67

No door on plan.

2L-4.68

4-68

No door on plan.

Apartment ID

Apartment ID

4-52

No door on plan.

Apartment ID

4-53

No door on plan.

No door on plan.

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

2L-4.69

Apartment ID

4-54

CLIENT REMARKS

2L-4.70

Apartment ID

4-69

4-70

No door on plan.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site Floor checked Buildings 2 and 3 - must Code be - Fourth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

No door on plan.

Approved SUBMITTAL: DATE:

2L-4.55

Apartment ID

4-55

No door on plan.

2L-4.71

Apartment ID

4-71

REVIEWED BY:

Not Approved

No door on plan.

APPROVED

Approved as Noted

2L-4.56

Apartment ID

4-56

No door on plan.

2L-4.72

Apartment ID

4-72

REVISE AND RESUBMIT

No door on plan.

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

2L-4.57

Apartment ID

2L-4.59

Apartment ID

2L-4.61

Apartment ID

2L-4.62

Apartment ID

2L-4.63

Apartment ID

4-57

No door on plan.

2L-4.73

Apartment ID

4-59

4-61

4-62

4-63

No door on plan. No T-58 on plan.

No door on plan. No T-60 on plan.

2L-4.74

Apartment ID

Apartment ID

4-64

4-74

No door on plan.

Total Qty: 4

STAIR 3-1

Door is not indicated on the plan.

3A-4.2

STAIR 3-2

Door is not indicated on the plan.

No door on plan.

Stair ID No door on plan.

Stair ID No door on plan.

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

3A-4.1 Stair ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

No door on plan.

3A : Stair ID

3A-4.3 2L-4.64

4-73

STAIR 3-3

Door is not indicated on the plan.

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Fourth Floor

8 Locations PAGE No. and Messages

IC.23

12.23


LOCATION

MESSAGE

DESIGNER NOTES

3A-4.4

STAIR 3-4

Door is not indicated on the plan.

Stair ID

3C : Egress Direction

3C-4.1

Egress Direction

STAIR 3-1 ROOF ACCESS

CLIENT REMARKS

LOCATION

MESSAGE

DESIGNER NOTES

3C-4.4

STAIR 3-4 ROOF ACCESS

Door is not indicated on the plan.

Egress Direction

Total Qty: 4 Door is not indicated on the plan.

Egress Direction

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] STAIR 3-2 ROOF ACCESS

INTERIOR CODE SIGNAGE

4 LEVEL 4

4 LEVEL 4

3C-4.2

CLIENT REMARKS

3E : Evac/In Case of Fire

3E-4.1

Evac/In Case of Fire

Door is not indicated on the plan.

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

Total Qty: 3

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Egress Direction

STAIR 3-3 ROOF ACCESS

3E-4.2

Evac/In Case of Fire

DRAWN BY JH

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

Approved as Noted

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

[EVAC MAP HOLDER] Door is not indicated on the plan.

3E-4.3

Evac/In Case of Fire

4 LEVEL 4 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site Floor checked Buildings 2 and 3 - must Code be - Fourth

APPROVED

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-4.3

Design-Build Package - POST FINAL REVISED

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

[EVAC MAP HOLDER] 4 LEVEL 4

DOCUMENT NAME / SUBMITTAL DATE

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

1 Round 2

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

[EVAC MAP HOLDER] 3J : Room ID (FOH)

3J-4.1

Room ID (FOH)

3J-4.2

Room ID (FOH)

TRASH

ELECTRICAL ROOM

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

Total Qty: 8

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Fourth Floor

8 Locations PAGE No. and Messages

IC.24

12.24


LOCATION

MESSAGE

3J-4.3

LOCATION

MESSAGE

ELECTRICAL ROOM

3L-4.8

4-08

3J-4.4

GAS METER ROOM

3L-4.9

4-09

3J-4.5

ELECTRICAL ROOM

3L-4.10

4-10

3J-4.6

GAS METER ROOM

3L-4.11

4-11

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

3J-4.7

Room ID (FOH)

ELECTRICAL ROOM

3J-4.8

HOUSEKEEPING

Room ID (FOH)

3L : Apartment ID

3L-4.1

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

Apartment ID

Apartment ID

Apartment ID

Apartment ID

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-4.12

Apartment ID

3L-4.13

Apartment ID

There is a room, but no door. Client to confirm if there is a door that isn’t shown on the plan.

4-12

4-13

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site Floor checked Buildings 2 and 3 - must Code be - Fourth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-4.14 Total Qty: 44

4-01

DESIGNER NOTES

Apartment ID

4-14

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-4.15

Apartment ID

4-15

REVISE AND RESUBMIT

4-16

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

4-17

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-4.2

Apartment ID

3L-4.3

Apartment ID

3L-4.4

Apartment ID

3L-4.5

Apartment ID

3L-4.6

Apartment ID

3L-4.7

Apartment ID

4-02

3L-4.16

Apartment ID

4-03

3L-4.17

Apartment ID

4-04

3L-4.18

Apartment ID

4-05

3L-4.19

Apartment ID

4-06

1 Round 2

4-18

4-19

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-4.20

Apartment ID

4-07

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

4-20

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-4.21

Apartment ID

4-21

SHEET NO.

Fourth Floor

8 Locations PAGE No. and Messages

IC.25

12.25


LOCATION

MESSAGE

3L-4.22

4-22

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-4.36

4-36

Apartment ID

3L-4.23

4-23

3L-4.37

4-37

3L-4.24

4-24

3L-4.38

4-38

3L-4.25

4-25

3L-4.39

4-39

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-4.26

Apartment ID

3L-4.27

Apartment ID

3L-4.28

Apartment ID

3L-4.29

Apartment ID

3L-4.30

Apartment ID

3L-4.31

Apartment ID

3L-4.32

Apartment ID

3L-4.33

Apartment ID

4-26

4-27

3L-4.40

Apartment ID

3L-4.41

Apartment ID

4-28

3L-4.42

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site Floor checked Buildings 2 and 3 - must Code be - Fourth

DRAWN BY

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

4-41

Approved SUBMITTAL: DATE:

4-42

APPROVED

Approved as Noted

3L-4.43

3L-4.45

4-43

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

4-45

There is no T-44 indicated on the plan.

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

4-32

4-33

JH

REVISE AND RESUBMIT

Apartment ID

4-31

Design-Build Package - POST FINAL REVISED

Not Approved

Apartment ID

4-30

There are 2 doors indicated on the plan. Client to confirm if this is an error.

REVIEWED BY:

Apartment ID

4-29

4-40

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-4.34

Apartment ID

4-34

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-4.35

Apartment ID

4-35

SHEET NO.

Fourth Floor

8 Locations PAGE No. and Messages

IC.26

12.26


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-5.2

3L-5.1

3L-5.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-5.4 3L-5.27

3L-5.26

3L-5.6

3L-5.5

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2L-5.52

3A-5.1

3C-5.1 3E-5.1 3L-5.8

3A-5.3

3L-5.10 3J-5.2 3L-5.18

3J-5.4 3J-5.5 3L-5.11

3L-5.20

3A-5.2 3L-5.15

2J-5.9

2L-5.56

3E-5.3

3L-5.23

3L-5.24

3L-5.25

3L-5.12 3L-5.14

3L-5.16

04.21.2021

Buildings 2 and 3 - Code - Fifth Floor CLIENT APPROVAL

JH

DRAWN BY

2E-5.4 SUBMITTAL: DATE:

3J-5.6

Not Approved

3L-5.36

Approved as Noted

2L-5.62

2L-5.61

3L-5.37

REVIEWED BY:

2L-5.60 2L-5.59

APPROVED

3C-5.4 3A-5.4

3L-5.39 3L-5.41

3L-5.17

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

2L-5.57

3L-5.35 3C-5.2

2L-5.58

2L-5.55

3L-5.34 3L-5.21

DOCUMENT NAME / SUBMITTAL DATE

3J-5.8 3J-5.7

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2C-5.5

2A-5.5

3L-5.32

3E-5.2

3L-5.19

3L-5.13

3L-5.22

2L-5.54

2L-5.53

3C-5.3

3L-5.33

3J-5.3

3L-5.9

3L-5.30

3L-5.31

3J-5.1

3L-5.7

2L-5.51

3L-5.28

3L-5.29

3L-5.43

2J-5.10

3L-5.38

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

2L-5.63 2J-5.11

3L-5.40 3L-5.42

2L-5.64 2J-5.12 2L-5.66

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

2L-5.65 3L-5.45

2L-5.67

No.

2L-5.68 2A-5.6 2L-5.70

2C-5.6 2L-5.69

2L-5.72

2L-5.71 2L-5.74 2L-5.73

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

5 Fifth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Fifth Floor

SECTION PAGE No.

8 Locations and Messages

IC.27

SHEET NO.

12.27


LOCATION

MESSAGE

2A : Stair ID

2A-5.5 Stair ID

2A-5.6 Stair ID

Egress Direction

2C-5.6

Egress Direction

CLIENT REMARKS

Total Qty: 2

STAIR 2-1

2J-5.10

Room ID (FOH)

Total Qty: 2

ELECTRICAL ROOM

5 LEVEL 5

2J-5.12

ELECTRICAL ROOM

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2L : Apartment ID

Room ID (FOH)

2L-5.51

Apartment ID

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

Total Qty: 4

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 24

5-51

INTERIOR CODE SIGNAGE

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Fifth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

2L-5.52

Apartment ID

STAIR 2-2 ROOF ACCESS

2E : Evac/In Case of Fire

CLIENT REMARKS

ELEC/ TELECOM ROOM

2J-5.11

Room ID (FOH)

DESIGNER NOTES

TRASH

STAIR 2-1 ROOF ACCESS

5-52

APPROVED

Approved as Noted

REVISE AND RESUBMIT

2L-5.53

5-53

2L-5.54

5-54

Apartment ID

Apartment ID

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Evac/In Case of Fire

MESSAGE

2J : Room ID (FOH)

Room ID (FOH)

5 LEVEL 5

2E-5.4

LOCATION

2J-5.9

STAIR 2-2

2C : Egress Direction

2C-5.5

DESIGNER NOTES

2L-5.55

5-55

2L-5.56

5-56

Apartment ID

Total Qty: 1

Apartment ID

2L-5.57

Apartment ID

2L-5.58

Apartment ID

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

5-57

5-58

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Fifth Floor

8 Locations PAGE No. and Messages

IC.28

12.28


LOCATION

MESSAGE

2L-5.59

5-59

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

2L-5.73

5-73

Apartment ID

2L-5.60

5-60

2L-5.74

2L-5.61

5-61

3A : Stair ID

Apartment ID

Apartment ID

Apartment ID

2L-5.62

Apartment ID

Apartment ID

Apartment ID

3A-5.2

STAIR 3-2

Apartment ID

2L-5.66

Apartment ID

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3A-5.3

DOCUMENT NAME / SUBMITTAL DATE

STAIR 3-3

5-64

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Fifth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3A-5.4

Approved

STAIR 3-4

SUBMITTAL: DATE: REVIEWED BY:

Not Approved

5-65 3C : Egress Direction

5-66

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

5-63

Stair ID

2L-5.65

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

5-62

Stair ID

2L-5.64

INTERIOR CODE SIGNAGE

Total Qty: 4

STAIR 3-1

Stair ID

2L-5.63

CLIENT REMARKS

5-74

3A-5.1 Stair ID

DESIGNER NOTES

3C-5.1

Egress Direction

STAIR 3-1 ROOF ACCESS

Total Qty: 4

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

2L-5.67

Apartment ID

2L-5.68

Apartment ID

2L-5.69

Apartment ID

2L-5.70

Apartment ID

5-67

5-68

5-69

5-70

5 LEVEL 5 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

2L-5.71

Apartment ID

5-71

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

2L-5.72

Apartment ID

5-72

SHEET NO.

Fifth Floor

8 Locations PAGE No. and Messages

IC.29

12.29


LOCATION

MESSAGE

3C-5.2

STAIR 3-2 ROOF ACCESS

Egress Direction

5 LEVEL 5 LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-5.3

Egress Direction

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Egress Direction

CLIENT REMARKS

LOCATION

STAIR 3-4 ROOF ACCESS

3E-5.1

Evac/In Case of Fire

3E-5.2

Evac/In Case of Fire

CLIENT REMARKS

Total Qty: 3

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

DOCUMENT NAME / SUBMITTAL DATE

[EVAC MAP HOLDER]

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Fifth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3E-5.3

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

[EVAC MAP HOLDER] 3J : Room ID (FOH)

3J-5.1

3J-5.2

Room ID (FOH)

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

DESIGNER NOTES

[EVAC MAP HOLDER]

Room ID (FOH)

5 LEVEL 5

MESSAGE

3E : Evac/In Case of Fire

STAIR 3-3 ROOF ACCESS 5 LEVEL 5

3C-5.4

DESIGNER NOTES

3J-5.3

Room ID (FOH)

TRASH

ELECTRICAL ROOM ELECTRICAL ROOM

3J-5.4

GAS METER ROOM

3J-5.5

ELECTRICAL ROOM

Room ID (FOH)

Room ID (FOH)

Total Qty: 8

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Fifth Floor

8 Locations PAGE No. and Messages

IC.30

12.30


LOCATION

MESSAGE

3J-5.6

Room ID (FOH)

3J-5.7

Room ID (FOH)

3J-5.8

Room ID (FOH)

LOCATION

MESSAGE

GAS METER ROOM

3L-5.11

5-11

ELEC/ TELECOM ROOM

3L-5.12

5-12

3L-5.13

5-13

3L-5.14

5-14

HOUSEKEEPING

3L : Apartment ID

3L-5.1

Apartment ID

3L-5.2

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

Apartment ID

Apartment ID

Apartment ID Room is not named on plan. Client to confirm room designation.

Total Qty: 44

5-01

Apartment ID

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-5.15

Apartment ID

5-02

DESIGNER NOTES

3L-5.16

Apartment ID

5-15

5-16

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Fifth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-5.3

Apartment ID

5-03

3L-5.17

Apartment ID

5-17

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-5.4

Apartment ID

5-04

3L-5.18

Apartment ID

5-18

REVISE AND RESUBMIT

5-19

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

5-20

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-5.5

Apartment ID

3L-5.6

Apartment ID

3L-5.7

Apartment ID

3L-5.8

Apartment ID

3L-5.9

Apartment ID

3L-5.10

Apartment ID

5-05

3L-5.19

Apartment ID

5-06

3L-5.20

Apartment ID

5-07

3L-5.21

Apartment ID

5-08

3L-5.22

Apartment ID

5-09

1 Round 2

5-21

5-22

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-5.23

Apartment ID

5-10

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

5-23

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-5.24

Apartment ID

5-24

SHEET NO.

Fifth Floor

8 Locations PAGE No. and Messages

IC.31

12.31


LOCATION

MESSAGE

3L-5.25

5-25

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-5.39

5-39

Apartment ID

3L-5.26

5-26

3L-5.40

5-40

3L-5.27

5-27

3L-5.41

5-41

3L-5.28

5-28

3L-5.42

5-42

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-5.29

Apartment ID

3L-5.30

Apartment ID

5-29

5-30

3L-5.43

Apartment ID

3L-5.45

Apartment ID

5-43

5-45

There is no T-44 indicated on the plan.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Fifth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-5.31

Apartment ID

5-31

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-5.32

Apartment ID

5-32

REVISE AND RESUBMIT

5-33

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

5-34

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-5.33

Apartment ID

3L-5.34

Apartment ID

3L-5.35

Apartment ID

3L-5.36

Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

5-35

5-36

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-5.37

Apartment ID

5-37

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-5.38

Apartment ID

5-38

SHEET NO.

Fifth Floor

8 Locations PAGE No. and Messages

IC.32

12.32


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-6.2

3L-6.1

3L-6.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-6.4 3L-6.27

3L-6.26

3L-6.6

3L-6.5

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2L-6.52

3A-6.1

3C-6.1 3E-6.1 3L-6.8

3A-6.3

3L-6.10 3J-6.2 3L-6.18

3J-6.4 3J-6.5 3L-6.11

3L-6.20

3A-6.2 3L-6.15

2J-6.9

2L-6.56

3E-6.3

3L-6.23

3L-6.24

3L-6.25

3L-6.12 3L-6.14

3L-6.16

04.21.2021

Buildings 2 and 3 - Code - Sixth Floor CLIENT APPROVAL

JH

DRAWN BY

2E-6.4 SUBMITTAL: DATE:

3J-6.6

Not Approved

3L-6.36

Approved as Noted

2L-6.62

2L-6.61

3L-6.37

REVIEWED BY:

2L-6.60 2L-6.59

APPROVED

3C-6.4 3A-6.4

3L-6.39 3L-6.41

3L-6.17

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

2L-6.57

3L-6.35 3C-6.2

2L-6.58

2L-6.55

3L-6.34 3L-6.21

DOCUMENT NAME / SUBMITTAL DATE

3J-6.8 3J-6.7

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2C-6.5

2A-6.5

3L-6.32

3E-6.2

3L-6.19

3L-6.13

3L-6.22

2L-6.54

2L-6.53

3C-6.3

3L-6.33

3J-6.3

3L-6.9

3L-6.30

3L-6.31

3J-6.1

3L-6.7

2L-6.51

3L-6.28

3L-6.29

3L-6.43

2J-6.10

3L-6.38

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

2L-6.63 2J-6.11

3L-6.40 3L-6.42

2L-6.64 2J-6.12 2L-6.66

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

2L-6.65 3L-6.45

2L-6.67

No.

2L-6.68 2A-6.6 2L-6.70

2C-6.6 2L-6.69

2L-6.72

2L-6.71 2L-6.74 2L-6.73

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

6 Sixth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Sixth Floor

SECTION PAGE No.

8 Locations and Messages

IC.33

SHEET NO.

12.33


LOCATION

MESSAGE

2A : Stair ID

2A-6.5 Stair ID

2A-6.6 Stair ID

Egress Direction

2C-6.6

Egress Direction

CLIENT REMARKS

Total Qty: 2

STAIR 2-1

2J-6.10

Room ID (FOH)

Total Qty: 2

ELECTRICAL ROOM

6 LEVEL 6

2J-6.12

ELECTRICAL ROOM

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2L : Apartment ID

Room ID (FOH)

2L-6.51

Apartment ID

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

Total Qty: 4

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 24

6-51

INTERIOR CODE SIGNAGE

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Sixth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

2L-6.52

Apartment ID

STAIR 2-2 ROOF ACCESS

2E : Evac/In Case of Fire

CLIENT REMARKS

ELEC/ TELECOM ROOM

2J-6.11

Room ID (FOH)

DESIGNER NOTES

TRASH

STAIR 2-1 ROOF ACCESS

6-52

APPROVED

Approved as Noted

REVISE AND RESUBMIT

2L-6.53

6-53

2L-6.54

6-54

Apartment ID

Apartment ID

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Evac/In Case of Fire

MESSAGE

2J : Room ID (FOH)

Room ID (FOH)

6 LEVEL 6

2E-6.4

LOCATION

2J-6.9

STAIR 2-2

2C : Egress Direction

2C-6.5

DESIGNER NOTES

2L-6.55

6-55

2L-6.56

6-56

Apartment ID

Total Qty: 1

Apartment ID

2L-6.57

Apartment ID

2L-6.58

Apartment ID

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

6-57

6-58

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Sixth Floor

8 Locations PAGE No. and Messages

IC.34

12.34


LOCATION

MESSAGE

2L-6.59

6-59

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

2L-6.73

6-73

Apartment ID

2L-6.60

6-60

2L-6.74

2L-6.61

6-61

3A : Stair ID

Apartment ID

Apartment ID

Apartment ID

2L-6.62

Apartment ID

Apartment ID

Apartment ID

3A-6.2

STAIR 3-2

Apartment ID

2L-6.66

Apartment ID

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3A-6.3

DOCUMENT NAME / SUBMITTAL DATE

STAIR 3-3

6-64

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Sixth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3A-6.4

Approved

STAIR 3-4

SUBMITTAL: DATE: REVIEWED BY:

Not Approved

6-65 3C : Egress Direction

6-66

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

6-63

Stair ID

2L-6.65

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

6-62

Stair ID

2L-6.64

INTERIOR CODE SIGNAGE

Total Qty: 4

STAIR 3-1

Stair ID

2L-6.63

CLIENT REMARKS

6-74

3A-6.1 Stair ID

DESIGNER NOTES

3C-6.1

Egress Direction

STAIR 3-1 ROOF ACCESS

Total Qty: 4

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

2L-6.67

Apartment ID

2L-6.68

Apartment ID

2L-6.69

Apartment ID

2L-6.70

Apartment ID

6-67

6-68

6-69

6-70

6 LEVEL 6 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

2L-6.71

Apartment ID

6-71

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

2L-6.72

Apartment ID

6-72

SHEET NO.

Sixth Floor

8 Locations PAGE No. and Messages

IC.35

12.35


LOCATION

MESSAGE

3C-6.2

STAIR 3-2 ROOF ACCESS

Egress Direction

6 LEVEL 6 LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-6.3

Egress Direction

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Egress Direction

CLIENT REMARKS

LOCATION

STAIR 3-4 ROOF ACCESS

3E-6.1

Evac/In Case of Fire

3E-6.2

Evac/In Case of Fire

CLIENT REMARKS

Total Qty: 3

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

DOCUMENT NAME / SUBMITTAL DATE

[EVAC MAP HOLDER]

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Sixth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3E-6.3

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

[EVAC MAP HOLDER] 3J : Room ID (FOH)

3J-6.1

3J-6.2

Room ID (FOH)

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

DESIGNER NOTES

[EVAC MAP HOLDER]

Room ID (FOH)

6 LEVEL 6

MESSAGE

3E : Evac/In Case of Fire

STAIR 3-3 ROOF ACCESS 6 LEVEL 6

3C-6.4

DESIGNER NOTES

3J-6.3

Room ID (FOH)

TRASH

ELECTRICAL ROOM ELECTRICAL ROOM

3J-6.4

GAS METER ROOM

3J-6.5

ELECTRICAL ROOM

Room ID (FOH)

Room ID (FOH)

Total Qty: 8

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Sixth Floor

8 Locations PAGE No. and Messages

IC.36

12.36


LOCATION

MESSAGE

3J-6.6

Room ID (FOH)

3J-6.7

Room ID (FOH)

3J-6.8

Room ID (FOH)

LOCATION

MESSAGE

GAS METER ROOM

3L-6.11

6-11

ELEC/ TELECOM ROOM

3L-6.12

6-12

3L-6.13

6-13

3L-6.14

6-14

HOUSEKEEPING

3L : Apartment ID

3L-6.1

Apartment ID

3L-6.2

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

Apartment ID

Apartment ID

Apartment ID Room is not named on plan. Client to confirm room designation.

Total Qty: 44

6-01

Apartment ID

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-6.15

Apartment ID

6-02

DESIGNER NOTES

3L-6.16

Apartment ID

6-15

6-16

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Sixth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-6.3

Apartment ID

6-03

3L-6.17

Apartment ID

6-17

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-6.4

Apartment ID

6-04

3L-6.18

Apartment ID

6-18

REVISE AND RESUBMIT

6-19

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

6-20

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-6.5

Apartment ID

3L-6.6

Apartment ID

3L-6.7

Apartment ID

3L-6.8

Apartment ID

3L-6.9

Apartment ID

3L-6.10

Apartment ID

6-05

3L-6.19

Apartment ID

6-06

3L-6.20

Apartment ID

6-07

3L-6.21

Apartment ID

6-08

3L-6.22

Apartment ID

6-09

1 Round 2

6-21

6-22

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-6.23

Apartment ID

6-10

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

6-23

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-6.24

Apartment ID

6-24

SHEET NO.

Sixth Floor

8 Locations PAGE No. and Messages

IC.37

12.37


LOCATION

MESSAGE

3L-6.25

6-25

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-6.39

6-39

Apartment ID

3L-6.26

6-26

3L-6.40

6-40

3L-6.27

6-27

3L-6.41

6-41

3L-6.28

6-28

3L-6.42

6-42

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-6.29

Apartment ID

3L-6.30

Apartment ID

6-29

6-30

3L-6.43

Apartment ID

3L-6.45

Apartment ID

6-43

6-45

There is no T-44 indicated on the plan.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Sixth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-6.31

Apartment ID

6-31

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-6.32

Apartment ID

6-32

REVISE AND RESUBMIT

6-33

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

6-34

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-6.33

Apartment ID

3L-6.34

Apartment ID

3L-6.35

Apartment ID

3L-6.36

Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

6-35

6-36

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-6.37

Apartment ID

6-37

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-6.38

Apartment ID

6-38

SHEET NO.

Sixth Floor

8 Locations PAGE No. and Messages

IC.38

12.38


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-7.2

3L-7.1

3L-7.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-7.4 3L-7.27

3L-7.26

3L-7.6

3L-7.5

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2L-7.52

3A-7.1

3C-7.1 3E-7.1 3L-7.8

3A-7.3

3L-7.10 3J-7.2 3L-7.18

3J-7.4 3J-7.5 3L-7.11

3L-7.20

3A-7.2 3L-7.15

2J-7.9

2L-7.56

3E-7.3

3L-7.23

3L-7.24

3L-7.25

3L-7.12 3L-7.14

3L-7.16

04.21.2021

Buildings 2 and 3 - Code - Seventh Floor CLIENT APPROVAL

JH

DRAWN BY

2E-7.4 SUBMITTAL: DATE:

3J-7.6

Not Approved

3L-7.36

Approved as Noted

2L-7.62

2L-7.61

3L-7.37

REVIEWED BY:

2L-7.60 2L-7.59

APPROVED

3C-7.4 3A-7.4

3L-7.39 3L-7.41

3L-7.17

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

2L-7.57

3L-7.35 3C-7.2

2L-7.58

2L-7.55

3L-7.34 3L-7.21

DOCUMENT NAME / SUBMITTAL DATE

3J-7.8 3J-7.7

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2C-7.5

2A-7.5

3L-7.32

3E-7.2

3L-7.19

3L-7.13

3L-7.22

2L-7.54

2L-7.53

3C-7.3

3L-7.33

3J-7.3

3L-7.9

3L-7.30

3L-7.31

3J-7.1

3L-7.7

2L-7.51

3L-7.28

3L-7.29

3L-7.43

2J-7.10

3L-7.38

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

2L-7.63 2J-7.11

3L-7.40 3L-7.42

2L-7.64 2J-7.12 2L-7.66

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

2L-7.65 3L-7.45

2L-7.67

No.

2L-7.68 2A-7.6 2L-7.70

2C-7.6 2L-7.69

2L-7.72

2L-7.71 2L-7.74 2L-7.73

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

7 Seventh Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Seventh Floor

SECTION PAGE No.

8 Locations and Messages

IC.39

SHEET NO.

12.39


LOCATION

MESSAGE

2A : Stair ID

2A-7.5 Stair ID

2A-7.6 Stair ID

Egress Direction

2C-7.6

Egress Direction

CLIENT REMARKS

Total Qty: 2

STAIR 2-1

2J-7.10

Room ID (FOH)

Total Qty: 2

ELECTRICAL ROOM

7 LEVEL 7

2J-7.12

ELECTRICAL ROOM

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2L : Apartment ID

Room ID (FOH)

2L-7.51

Apartment ID

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

Total Qty: 4

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 24

7-51

INTERIOR CODE SIGNAGE

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Seventh Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

2L-7.52

Apartment ID

STAIR 2-2 ROOF ACCESS

2E : Evac/In Case of Fire

CLIENT REMARKS

ELEC/ TELECOM ROOM

2J-7.11

Room ID (FOH)

DESIGNER NOTES

TRASH

STAIR 2-1 ROOF ACCESS

7-52

APPROVED

Approved as Noted

REVISE AND RESUBMIT

2L-7.53

7-53

2L-7.54

7-54

Apartment ID

Apartment ID

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Evac/In Case of Fire

MESSAGE

2J : Room ID (FOH)

Room ID (FOH)

7 LEVEL 7

2E-7.4

LOCATION

2J-7.9

STAIR 2-2

2C : Egress Direction

2C-7.5

DESIGNER NOTES

2L-7.55

7-55

2L-7.56

7-56

Apartment ID

Total Qty: 1

Apartment ID

2L-7.57

Apartment ID

2L-7.58

Apartment ID

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

7-57

7-58

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Seventh Floor

8 Locations PAGE No. and Messages

IC.40

12.40


LOCATION

MESSAGE

2L-7.59

7-59

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

2L-7.73

7-73

Apartment ID

2L-7.60

7-60

2L-7.74

2L-7.61

7-61

3A : Stair ID

Apartment ID

Apartment ID

Apartment ID

2L-7.62

Apartment ID

Apartment ID

Apartment ID

3A-7.2

STAIR 3-2

Apartment ID

2L-7.66

Apartment ID

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3A-7.3

DOCUMENT NAME / SUBMITTAL DATE

STAIR 3-3

7-64

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Seventh Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3A-7.4

Approved

STAIR 3-4

SUBMITTAL: DATE: REVIEWED BY:

Not Approved

7-65 3C : Egress Direction

7-66

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

7-63

Stair ID

2L-7.65

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

7-62

Stair ID

2L-7.64

INTERIOR CODE SIGNAGE

Total Qty: 4

STAIR 3-1

Stair ID

2L-7.63

CLIENT REMARKS

7-74

3A-7.1 Stair ID

DESIGNER NOTES

3C-7.1

Egress Direction

STAIR 3-1 ROOF ACCESS

Total Qty: 4

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

2L-7.67

Apartment ID

2L-7.68

Apartment ID

2L-7.69

Apartment ID

2L-7.70

Apartment ID

7-67

7-68

7-69

7-70

7 LEVEL 7 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

2L-7.71

Apartment ID

7-71

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

2L-7.72

Apartment ID

7-72

SHEET NO.

Seventh Floor

8 Locations PAGE No. and Messages

IC.41

12.41


LOCATION

MESSAGE

3C-7.2

STAIR 3-2 ROOF ACCESS

Egress Direction

7 LEVEL 7 LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-7.3

Egress Direction

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Egress Direction

CLIENT REMARKS

LOCATION

STAIR 3-4 ROOF ACCESS

3E-7.1

Evac/In Case of Fire

3E-7.2

Evac/In Case of Fire

CLIENT REMARKS

Total Qty: 3

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

DOCUMENT NAME / SUBMITTAL DATE

[EVAC MAP HOLDER]

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Seventh Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3E-7.3

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

[EVAC MAP HOLDER] 3J : Room ID (FOH)

3J-7.1

3J-7.2

Room ID (FOH)

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

DESIGNER NOTES

[EVAC MAP HOLDER]

Room ID (FOH)

7 LEVEL 7

MESSAGE

3E : Evac/In Case of Fire

STAIR 3-3 ROOF ACCESS 7 LEVEL 7

3C-7.4

DESIGNER NOTES

3J-7.3

Room ID (FOH)

TRASH

ELECTRICAL ROOM ELECTRICAL ROOM

3J-7.4

GAS METER ROOM

3J-7.5

ELECTRICAL ROOM

Room ID (FOH)

Room ID (FOH)

Total Qty: 8

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Seventh Floor

8 Locations PAGE No. and Messages

IC.42

12.42


LOCATION

MESSAGE

3J-7.6

Room ID (FOH)

3J-7.7

Room ID (FOH)

3J-7.8

Room ID (FOH)

LOCATION

MESSAGE

GAS METER ROOM

3L-7.11

7-11

ELEC/ TELECOM ROOM

3L-7.12

7-12

3L-7.13

7-13

3L-7.14

7-14

HOUSEKEEPING

3L : Apartment ID

3L-7.1

Apartment ID

3L-7.2

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

Apartment ID

Apartment ID

Apartment ID Room is not named on plan. Client to confirm room designation.

Total Qty: 44

7-01

Apartment ID

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-7.15

Apartment ID

7-02

DESIGNER NOTES

3L-7.16

Apartment ID

7-15

7-16

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Seventh Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-7.3

Apartment ID

7-03

3L-7.17

Apartment ID

7-17

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-7.4

Apartment ID

7-04

3L-7.18

Apartment ID

7-18

REVISE AND RESUBMIT

7-19

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

7-20

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-7.5

Apartment ID

3L-7.6

Apartment ID

3L-7.7

Apartment ID

3L-7.8

Apartment ID

3L-7.9

Apartment ID

3L-7.10

Apartment ID

7-05

3L-7.19

Apartment ID

7-06

3L-7.20

Apartment ID

7-07

3L-7.21

Apartment ID

7-08

3L-7.22

Apartment ID

7-09

1 Round 2

7-21

7-22

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-7.23

Apartment ID

7-10

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

7-23

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-7.24

Apartment ID

7-24

SHEET NO.

Seventh Floor

8 Locations PAGE No. and Messages

IC.43

12.43


LOCATION

MESSAGE

3L-7.25

7-25

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-7.39

7-39

Apartment ID

3L-7.26

7-26

3L-7.40

7-40

3L-7.27

7-27

3L-7.41

7-41

3L-7.28

7-28

3L-7.42

7-42

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-7.29

Apartment ID

3L-7.30

Apartment ID

7-29

7-30

3L-7.43

Apartment ID

3L-7.45

Apartment ID

7-43

7-45

There is no T-44 indicated on the plan.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Seventh Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-7.31

Apartment ID

7-31

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-7.32

Apartment ID

7-32

REVISE AND RESUBMIT

7-33

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

7-34

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-7.33

Apartment ID

3L-7.34

Apartment ID

3L-7.35

Apartment ID

3L-7.36

Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

7-35

7-36

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-7.37

Apartment ID

7-37

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-7.38

Apartment ID

7-38

SHEET NO.

Seventh Floor

8 Locations PAGE No. and Messages

IC.44

12.44


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-8.2

3L-8.1

3L-8.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-8.4 3L-8.27

3L-8.26

3L-8.6

3L-8.5

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2L-8.52

3A-8.1

3C-8.1 3E-8.1 3L-8.8

3A-8.3

3L-8.10 3J-8.2 3L-8.18

3J-8.4 3J-8.5 3L-8.11

3L-8.20

2J-8.9

2L-8.56

3E-8.3

3L-8.23

3L-8.24

3L-8.25

3C-8.2 3L-8.12

3L-8.15

3L-8.14

3L-8.16

04.21.2021

Buildings 2 and 3 - Code - Eighth Floor CLIENT APPROVAL

JH

DRAWN BY

2E-8.4 SUBMITTAL: DATE:

3J-8.6

Not Approved

3L-8.36

Approved as Noted

2L-8.62

2L-8.61

3L-8.37

REVIEWED BY:

2L-8.60 2L-8.59

APPROVED

3C-8.4 3A-8.4

3L-8.39 3L-8.41

3L-8.17

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

2L-8.57

3L-8.35

3A-8.2

2L-8.58

2L-8.55

3L-8.34 3L-8.21

DOCUMENT NAME / SUBMITTAL DATE

3J-8.8 3J-8.7

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2C-8.5

2A-8.5

3L-8.32

3E-8.2

3L-8.19

3L-8.13

3L-8.22

2L-8.54

2L-8.53

3C-8.3

3L-8.33

3J-8.3

3L-8.9

3L-8.30

3L-8.31

3J-8.1

3L-8.7

2L-8.51

3L-8.28

3L-8.29

3L-8.43

2J-8.10

3L-8.38

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

2L-8.63 2J-8.11

3L-8.40 3L-8.42

2L-8.64 2J-8.12 2L-8.66

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

2L-8.65 3L-8.45

2L-8.67

No.

2L-8.68 2A-8.6 2L-8.70

2C-8.6 2L-8.69

2L-8.72

2L-8.71 2L-8.74 2L-8.73

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

8 Eighth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Eighth Floor

SECTION PAGE No.

8 Locations and Messages

IC.45

SHEET NO.

12.45


LOCATION

MESSAGE

2A : Stair ID

2A-8.5 Stair ID

2A-8.6 Stair ID

Egress Direction

2C-8.6

Egress Direction

CLIENT REMARKS

Total Qty: 2

STAIR 2-1

2J-8.10

Room ID (FOH)

Total Qty: 2

ELECTRICAL ROOM

8 LEVEL 8

2J-8.12

ELECTRICAL ROOM

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2L : Apartment ID

Room ID (FOH)

2L-8.51

Apartment ID

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

Total Qty: 4

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 24

8-51

INTERIOR CODE SIGNAGE

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site Floor checked Buildings 2 and 3 - must Code be - Eighth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

2L-8.52

Apartment ID

STAIR 2-2 ROOF ACCESS

2E : Evac/In Case of Fire

CLIENT REMARKS

ELEC/ TELECOM ROOM

2J-8.11

Room ID (FOH)

DESIGNER NOTES

TRASH

STAIR 2-1 ROOF ACCESS

8-52

APPROVED

Approved as Noted

REVISE AND RESUBMIT

2L-8.53

8-53

2L-8.54

8-54

Apartment ID

Apartment ID

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Evac/In Case of Fire

MESSAGE

2J : Room ID (FOH)

Room ID (FOH)

8 LEVEL 8

2E-8.4

LOCATION

2J-8.9

STAIR 2-2

2C : Egress Direction

2C-8.5

DESIGNER NOTES

2L-8.55

8-55

2L-8.56

8-56

Apartment ID

Total Qty: 1

Apartment ID

2L-8.57

Apartment ID

2L-8.58

Apartment ID

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

8-57

8-58

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Eighth Floor

8 Locations PAGE No. and Messages

IC.46

12.46


LOCATION

MESSAGE

2L-8.59

8-59

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

2L-8.73

8-73

Apartment ID

2L-8.60

8-60

2L-8.74

2L-8.61

8-61

3A : Stair ID

Apartment ID

Apartment ID

Apartment ID

2L-8.62

Apartment ID

Apartment ID

Apartment ID

3A-8.2

STAIR 3-2

Apartment ID

2L-8.66

Apartment ID

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3A-8.3

DOCUMENT NAME / SUBMITTAL DATE

STAIR 3-3

8-64

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site Floor checked Buildings 2 and 3 - must Code be - Eighth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3A-8.4

Approved

STAIR 3-4

SUBMITTAL: DATE: REVIEWED BY:

Not Approved

8-65 3C : Egress Direction

8-66

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

8-63

Stair ID

2L-8.65

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

8-62

Stair ID

2L-8.64

INTERIOR CODE SIGNAGE

Total Qty: 4

STAIR 3-1

Stair ID

2L-8.63

CLIENT REMARKS

8-74

3A-8.1 Stair ID

DESIGNER NOTES

3C-8.1

Egress Direction

STAIR 3-1 ROOF ACCESS

Total Qty: 4

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

2L-8.67

Apartment ID

2L-8.68

Apartment ID

2L-8.69

Apartment ID

2L-8.70

Apartment ID

8-67

8-68

8-69

8-70

8 LEVEL 8 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

2L-8.71

Apartment ID

8-71

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

2L-8.72

Apartment ID

8-72

SHEET NO.

Eighth Floor

8 Locations PAGE No. and Messages

IC.47

12.47


LOCATION

MESSAGE

3C-8.2

STAIR 3-2 ROOF ACCESS

Egress Direction

8 LEVEL 8 LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-8.3

Egress Direction

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Egress Direction

CLIENT REMARKS

LOCATION

STAIR 3-4 ROOF ACCESS

3E-8.1

Evac/In Case of Fire

3E-8.2

Evac/In Case of Fire

CLIENT REMARKS

Total Qty: 3

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

DOCUMENT NAME / SUBMITTAL DATE

[EVAC MAP HOLDER]

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site Floor checked Buildings 2 and 3 - must Code be - Eighth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3E-8.3

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

[EVAC MAP HOLDER] 3J : Room ID (FOH)

3J-8.1

3J-8.2

Room ID (FOH)

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

DESIGNER NOTES

[EVAC MAP HOLDER]

Room ID (FOH)

8 LEVEL 8

MESSAGE

3E : Evac/In Case of Fire

STAIR 3-3 ROOF ACCESS 8 LEVEL 8

3C-8.4

DESIGNER NOTES

3J-8.3

Room ID (FOH)

TRASH

ELECTRICAL ROOM ELECTRICAL ROOM

3J-8.4

GAS METER ROOM

3J-8.5

ELECTRICAL ROOM

Room ID (FOH)

Room ID (FOH)

Total Qty: 8

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Eighth Floor

8 Locations PAGE No. and Messages

IC.48

12.48


LOCATION

MESSAGE

3J-8.6

Room ID (FOH)

3J-8.7

Room ID (FOH)

3J-8.8

Room ID (FOH)

LOCATION

MESSAGE

GAS METER ROOM

3L-8.11

8-11

ELEC/ TELECOM ROOM

3L-8.12

8-12

3L-8.13

8-13

3L-8.14

8-14

HOUSEKEEPING

3L : Apartment ID

3L-8.1

Apartment ID

3L-8.2

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

Apartment ID

Apartment ID

Apartment ID Room is not named on plan. Client to confirm room designation.

Total Qty: 44

8-01

Apartment ID

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-8.15

Apartment ID

8-02

DESIGNER NOTES

3L-8.16

Apartment ID

8-15

8-16

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site Floor checked Buildings 2 and 3 - must Code be - Eighth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-8.3

Apartment ID

8-03

3L-8.17

Apartment ID

8-17

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-8.4

Apartment ID

8-04

3L-8.18

Apartment ID

8-18

REVISE AND RESUBMIT

8-19

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

8-20

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-8.5

Apartment ID

3L-8.6

Apartment ID

3L-8.7

Apartment ID

3L-8.8

Apartment ID

3L-8.9

Apartment ID

3L-8.10

Apartment ID

8-05

3L-8.19

Apartment ID

8-06

3L-8.20

Apartment ID

8-07

3L-8.21

Apartment ID

8-08

3L-8.22

Apartment ID

8-09

1 Round 2

8-21

8-22

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-8.23

Apartment ID

8-10

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

8-23

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-8.24

Apartment ID

8-24

SHEET NO.

Eighth Floor

8 Locations PAGE No. and Messages

IC.49

12.49


LOCATION

MESSAGE

3L-8.25

8-25

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-8.39

8-39

Apartment ID

3L-8.26

8-26

3L-8.40

8-40

3L-8.27

8-27

3L-8.41

8-41

3L-8.28

8-28

3L-8.42

8-42

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-8.29

Apartment ID

3L-8.30

Apartment ID

8-29

8-30

3L-8.43

Apartment ID

3L-8.45

Apartment ID

8-43

8-45

There is no T-44 indicated on the plan.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site Floor checked Buildings 2 and 3 - must Code be - Eighth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-8.31

Apartment ID

8-31

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-8.32

Apartment ID

8-32

REVISE AND RESUBMIT

8-33

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

8-34

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-8.33

Apartment ID

3L-8.34

Apartment ID

3L-8.35

Apartment ID

3L-8.36

Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

8-35

8-36

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-8.37

Apartment ID

8-37

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-8.38

Apartment ID

8-38

SHEET NO.

Eighth Floor

8 Locations PAGE No. and Messages

IC.50

12.50


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-9.2

3L-9.1

3L-9.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-9.4 3L-9.27

3L-9.26

3L-9.6

3L-9.5

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2L-9.52

3A-9.1

3C-9.1 3E-9.1 3L-9.8

3A-9.3

3L-9.10 3J-9.2 3L-9.18

3J-9.4 3J-9.5 3L-9.11

3L-9.20

3A-9.2 3L-9.15

2J-9.9

2L-9.56

3E-9.3

3L-9.23

3L-9.24

3L-9.25

3L-9.12 3L-9.14

3L-9.16

04.21.2021

Buildings 2 and 3 - Code - Ninth Floor CLIENT APPROVAL

JH

DRAWN BY

2E-9.4 SUBMITTAL: DATE:

3J-9.6

Not Approved

3L-9.36

Approved as Noted

2L-9.62

2L-9.61

3L-9.37

REVIEWED BY:

2L-9.60 2L-9.59

APPROVED

3C-9.4 3A-9.4

3L-9.39 3L-9.41

3L-9.17

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

2L-9.57

3L-9.35 3C-9.2

2L-9.58

2L-9.55

3L-9.34 3L-9.21

DOCUMENT NAME / SUBMITTAL DATE

3J-9.8 3J-9.7

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2C-9.5

2A-9.5

3L-9.32

3E-9.2

3L-9.19

3L-9.13

3L-9.22

2L-9.54

2L-9.53

3C-9.3

3L-9.33

3J-9.3

3L-9.9

3L-9.30

3L-9.31

3J-9.1

3L-9.7

2L-9.51

3L-9.28

3L-9.29

3L-9.43

2J-9.10

3L-9.38

REVISE AND RESUBMIT

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

2L-9.63 2J-9.11

3L-9.40 3L-9.42

2L-9.64 2J-9.12 2L-9.66

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

2L-9.65 3L-9.45

2L-9.67

No.

2L-9.68 2A-9.6 2L-9.70

2C-9.6 2L-9.69

2L-9.72

2L-9.71 2L-9.74 2L-9.73

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

9 Ninth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Ninth Floor

SECTION PAGE No.

8 Locations and Messages

IC.51

SHEET NO.

12.51


LOCATION

MESSAGE

2A : Stair ID

2A-9.5 Stair ID

2A-9.6 Stair ID

Egress Direction

2C-9.6

Egress Direction

CLIENT REMARKS

Total Qty: 2

STAIR 2-1

2J-9.10

Room ID (FOH)

Total Qty: 2

ELECTRICAL ROOM

9 LEVEL 9

2J-9.12

ELECTRICAL ROOM

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2L : Apartment ID

Room ID (FOH)

2L-9.51

Apartment ID

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

Total Qty: 4

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 24

9-51

INTERIOR CODE SIGNAGE

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Ninth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

2L-9.52

Apartment ID

STAIR 2-2 ROOF ACCESS

2E : Evac/In Case of Fire

CLIENT REMARKS

ELEC/ TELECOM ROOM

2J-9.11

Room ID (FOH)

DESIGNER NOTES

TRASH

STAIR 2-1 ROOF ACCESS

9-52

APPROVED

Approved as Noted

REVISE AND RESUBMIT

2L-9.53

9-53

2L-9.54

9-54

Apartment ID

Apartment ID

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Evac/In Case of Fire

MESSAGE

2J : Room ID (FOH)

Room ID (FOH)

9 LEVEL 9

2E-9.4

LOCATION

2J-9.9

STAIR 2-2

2C : Egress Direction

2C-9.5

DESIGNER NOTES

2L-9.55

9-55

2L-9.56

9-56

Apartment ID

Total Qty: 1

Apartment ID

2L-9.57

Apartment ID

2L-9.58

Apartment ID

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

9-57

9-58

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Ninth Floor

8 Locations PAGE No. and Messages

IC.52

12.52


LOCATION

MESSAGE

2L-9.59

9-59

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

2L-9.73

9-73

Apartment ID

2L-9.60

9-60

2L-9.74

2L-9.61

9-61

3A : Stair ID

Apartment ID

Apartment ID

Apartment ID

2L-9.62

Apartment ID

Apartment ID

Apartment ID

3A-9.2

STAIR 3-2

Apartment ID

2L-9.66

Apartment ID

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3A-9.3

DOCUMENT NAME / SUBMITTAL DATE

STAIR 3-3

9-64

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Ninth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3A-9.4

Approved

STAIR 3-4

SUBMITTAL: DATE: REVIEWED BY:

Not Approved

9-65 3C : Egress Direction

9-66

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

9-63

Stair ID

2L-9.65

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

9-62

Stair ID

2L-9.64

INTERIOR CODE SIGNAGE

Total Qty: 4

STAIR 3-1

Stair ID

2L-9.63

CLIENT REMARKS

9-74

3A-9.1 Stair ID

DESIGNER NOTES

3C-9.1

Egress Direction

STAIR 3-1 ROOF ACCESS

Total Qty: 4

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

2L-9.67

Apartment ID

2L-9.68

Apartment ID

2L-9.69

Apartment ID

2L-9.70

Apartment ID

9-67

9-68

9-69

9-70

9 LEVEL 9 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

2L-9.71

Apartment ID

9-71

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

2L-9.72

Apartment ID

9-72

SHEET NO.

Ninth Floor

8 Locations PAGE No. and Messages

IC.53

12.53


LOCATION

MESSAGE

3C-9.2

STAIR 3-2 ROOF ACCESS

Egress Direction

9 LEVEL 9 LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-9.3

Egress Direction

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Egress Direction

CLIENT REMARKS

LOCATION

STAIR 3-4 ROOF ACCESS

3E-9.1

Evac/In Case of Fire

3E-9.2

Evac/In Case of Fire

CLIENT REMARKS

Total Qty: 3

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

DOCUMENT NAME / SUBMITTAL DATE

[EVAC MAP HOLDER]

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Ninth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3E-9.3

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

[EVAC MAP HOLDER] 3J : Room ID (FOH)

3J-9.1

3J-9.2

Room ID (FOH)

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

DESIGNER NOTES

[EVAC MAP HOLDER]

Room ID (FOH)

9 LEVEL 9

MESSAGE

3E : Evac/In Case of Fire

STAIR 3-3 ROOF ACCESS 9 LEVEL 9

3C-9.4

DESIGNER NOTES

3J-9.3

Room ID (FOH)

TRASH

ELECTRICAL ROOM ELECTRICAL ROOM

3J-9.4

GAS METER ROOM

3J-9.5

ELECTRICAL ROOM

Room ID (FOH)

Room ID (FOH)

Total Qty: 8

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Ninth Floor

8 Locations PAGE No. and Messages

IC.54

12.54


LOCATION

MESSAGE

3J-9.6

Room ID (FOH)

3J-9.7

Room ID (FOH)

3J-9.8

Room ID (FOH)

LOCATION

MESSAGE

GAS METER ROOM

3L-9.11

9-11

ELEC/ TELECOM ROOM

3L-9.12

9-12

3L-9.13

9-13

3L-9.14

9-14

HOUSEKEEPING

3L : Apartment ID

3L-9.1

Apartment ID

3L-9.2

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

Apartment ID

Apartment ID

Apartment ID Room is not named on plan. Client to confirm room designation.

Total Qty: 44

9-01

Apartment ID

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-9.15

Apartment ID

9-02

DESIGNER NOTES

3L-9.16

Apartment ID

9-15

9-16

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Ninth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-9.3

Apartment ID

9-03

3L-9.17

Apartment ID

9-17

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-9.4

Apartment ID

9-04

3L-9.18

Apartment ID

9-18

REVISE AND RESUBMIT

9-19

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

9-20

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-9.5

Apartment ID

3L-9.6

Apartment ID

3L-9.7

Apartment ID

3L-9.8

Apartment ID

3L-9.9

Apartment ID

3L-9.10

Apartment ID

9-05

3L-9.19

Apartment ID

9-06

3L-9.20

Apartment ID

9-07

3L-9.21

Apartment ID

9-08

3L-9.22

Apartment ID

9-09

1 Round 2

9-21

9-22

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-9.23

Apartment ID

9-10

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

9-23

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-9.24

Apartment ID

9-24

SHEET NO.

Ninth Floor

8 Locations PAGE No. and Messages

IC.55

12.55


LOCATION

MESSAGE

3L-9.25

9-25

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-9.39

9-39

Apartment ID

3L-9.26

9-26

3L-9.40

9-40

3L-9.27

9-27

3L-9.41

9-41

3L-9.28

9-28

3L-9.42

9-42

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-9.29

Apartment ID

3L-9.30

Apartment ID

9-29

9-30

3L-9.43

Apartment ID

3L-9.45

Apartment ID

9-43

9-45

There is no T-44 indicated on the plan.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Ninth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-9.31

Apartment ID

9-31

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-9.32

Apartment ID

9-32

REVISE AND RESUBMIT

9-33

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

9-34

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-9.33

Apartment ID

3L-9.34

Apartment ID

3L-9.35

Apartment ID

3L-9.36

Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

9-35

9-36

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-9.37

Apartment ID

9-37

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-9.38

Apartment ID

9-38

SHEET NO.

Ninth Floor

8 Locations PAGE No. and Messages

IC.56

12.56


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-10.2

3L-10.1

3L-10.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-10.4 3L-10.27

3L-10.26

3L-10.6

3L-10.5

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2L-10.52

3A-10.1

3C-10.1 3E-10.1 3L-10.8

3A-10.3

3L-10.10 3J-10.2 3L-10.18

3J-10.4 3J-10.5 3L-10.11

3L-10.15

2L-10.56

3L-10.24

3L-10.23 3L-10.25

3L-10.12 3L-10.14

3L-10.16

04.21.2021

Buildings 2 and 3 - Code - Tenth Floor CLIENT APPROVAL

JH

DRAWN BY

2E-10.4 SUBMITTAL: DATE:

3J-10.6

Not Approved

3L-10.36

Approved as Noted

2L-10.62

2L-10.61

3L-10.37

REVIEWED BY:

2L-10.60 2L-10.59

APPROVED

3C-10.4 3A-10.4

3L-10.39 3L-10.41

3L-10.17

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

2L-10.57

3L-10.35 3C-10.2

2L-10.58

2L-10.55

3L-10.34 3L-10.21

DOCUMENT NAME / SUBMITTAL DATE

2A-10.5

3E-10.3

3E-10.2

3L-10.19

3L-10.13 3A-10.2

3L-10.20

3L-10.22

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2C-10.5

2J-10.9

3L-10.32 3J-10.8

3J-10.7

2L-10.54

2L-10.53

3C-10.3

3L-10.33

3J-10.3

3L-10.9

3L-10.30

3L-10.31

3J-10.1

3L-10.7

2L-10.51

3L-10.28

3L-10.29

3L-10.43

2J-10.10

3L-10.38

REVISE AND RESUBMIT

2L-10.63 2J-10.11

3L-10.40 3L-10.42

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

2L-10.64 2J-10.12 2L-10.66

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

2L-10.65 3L-10.45

2L-10.67

No.

2L-10.68 2A-10.6 2L-10.70

2C-10.6 2L-10.69

2L-10.72

2L-10.71 2L-10.74 2L-10.73

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

10 Tenth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Tenth Floor

SECTION PAGE No.

8 Locations and Messages

IC.57

SHEET NO.

12.57


LOCATION

MESSAGE

2A : Stair ID

2A-10.5 Stair ID

2A-10.6 Stair ID

Egress Direction

2C-10.6

Egress Direction

CLIENT REMARKS

Total Qty: 2

STAIR 2-1

2J-10.10

Room ID (FOH)

Total Qty: 2

ELECTRICAL ROOM

10 LEVEL 10

2J-10.12

ELECTRICAL ROOM

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2L : Apartment ID

Room ID (FOH)

2L-10.51 Apartment ID

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

Total Qty: 4

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 24

10-51

INTERIOR CODE SIGNAGE

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Tenth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

2L-10.52 Apartment ID

STAIR 2-2 ROOF ACCESS

2E : Evac/In Case of Fire

CLIENT REMARKS

ELEC/ TELECOM ROOM

2J-10.11

Room ID (FOH)

DESIGNER NOTES

TRASH

STAIR 2-1 ROOF ACCESS

10-52

APPROVED

Approved as Noted

REVISE AND RESUBMIT

2L-10.53

10-53

2L-10.54

10-54

Apartment ID

Apartment ID

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Evac/In Case of Fire

MESSAGE

2J : Room ID (FOH)

Room ID (FOH)

10 LEVEL 10

2E-10.4

LOCATION

2J-10.9

STAIR 2-2

2C : Egress Direction

2C-10.5

DESIGNER NOTES

2L-10.55

10-55

2L-10.56

10-56

Apartment ID

Total Qty: 1

Apartment ID

2L-10.57 Apartment ID

2L-10.58 Apartment ID

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

10-57

10-58

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Tenth Floor

8 Locations PAGE No. and Messages

IC.58

12.58


LOCATION

MESSAGE

2L-10.59

10-59

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

2L-10.73

10-73

Apartment ID

2L-10.60

10-60

2L-10.74

2L-10.61

10-61

3A : Stair ID

Apartment ID

Apartment ID

Apartment ID

2L-10.62 Apartment ID

Apartment ID

Apartment ID

3A-10.2

STAIR 3-2

Apartment ID

2L-10.66 Apartment ID

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3A-10.3

DOCUMENT NAME / SUBMITTAL DATE

STAIR 3-3

10-64

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Tenth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3A-10.4

Approved

STAIR 3-4

SUBMITTAL: DATE: REVIEWED BY:

Not Approved

10-65 3C : Egress Direction

10-66

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

10-63

Stair ID

2L-10.65

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

10-62

Stair ID

2L-10.64

INTERIOR CODE SIGNAGE

Total Qty: 4

STAIR 3-1

Stair ID

2L-10.63

CLIENT REMARKS

10-74

3A-10.1 Stair ID

DESIGNER NOTES

3C-10.1

Egress Direction

STAIR 3-1 ROOF ACCESS

Total Qty: 4

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

2L-10.67 Apartment ID

2L-10.68 Apartment ID

2L-10.69 Apartment ID

2L-10.70 Apartment ID

10-67

10-68

10-69

10-70

10 LEVEL 10 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

2L-10.71 Apartment ID

10-71

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

2L-10.72 Apartment ID

10-72

SHEET NO.

Tenth Floor

8 Locations PAGE No. and Messages

IC.59

12.59


LOCATION

MESSAGE

3C-10.2

STAIR 3-2 ROOF ACCESS

Egress Direction

10 LEVEL 10 LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-10.3

Egress Direction

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Egress Direction

CLIENT REMARKS

LOCATION

STAIR 3-4 ROOF ACCESS

3E-10.1

Evac/In Case of Fire

3E-10.2

Evac/In Case of Fire

CLIENT REMARKS

Total Qty: 3

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

DOCUMENT NAME / SUBMITTAL DATE

[EVAC MAP HOLDER]

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Tenth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3E-10.3

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

[EVAC MAP HOLDER] 3J : Room ID (FOH)

3J-10.1

3J-10.2

Room ID (FOH)

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

DESIGNER NOTES

[EVAC MAP HOLDER]

Room ID (FOH)

10 LEVEL 10

MESSAGE

3E : Evac/In Case of Fire

STAIR 3-3 ROOF ACCESS 10 LEVEL 10

3C-10.4

DESIGNER NOTES

3J-10.3

Room ID (FOH)

TRASH

ELECTRICAL ROOM ELECTRICAL ROOM

3J-10.4

GAS METER ROOM

3J-10.5

ELECTRICAL ROOM

Room ID (FOH)

Room ID (FOH)

Total Qty: 8

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Tenth Floor

8 Locations PAGE No. and Messages

IC.60

12.60


LOCATION

MESSAGE

3J-10.6

Room ID (FOH)

3J-10.7

Room ID (FOH)

3J-10.8

Room ID (FOH)

LOCATION

MESSAGE

GAS METER ROOM

3L-10.11

10-11

ELEC/ TELECOM ROOM

3L-10.12

10-12

3L-10.13

10-13

3L-10.14

10-14

HOUSEKEEPING

3L : Apartment ID

3L-10.1

Apartment ID

3L-10.2

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

Apartment ID

Apartment ID

Apartment ID Room is not named on plan. Client to confirm room designation.

Total Qty: 44

10-01

Apartment ID

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-10.15 Apartment ID

10-02

DESIGNER NOTES

3L-10.16 Apartment ID

10-15

10-16

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Tenth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-10.3

Apartment ID

10-03

3L-10.17 Apartment ID

10-17

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-10.4

Apartment ID

10-04

3L-10.18 Apartment ID

10-18

REVISE AND RESUBMIT

10-19

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

10-20

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-10.5

Apartment ID

3L-10.6

Apartment ID

3L-10.7

Apartment ID

3L-10.8

Apartment ID

3L-10.9

Apartment ID

3L-10.10 Apartment ID

10-05

3L-10.19 Apartment ID

10-06

3L-10.20 Apartment ID

10-07

3L-10.21 Apartment ID

10-08

3L-10.22 Apartment ID

10-09

1 Round 2

10-21

10-22

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-10.23 Apartment ID

10-10

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

10-23

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-10.24 Apartment ID

10-24

SHEET NO.

Tenth Floor

8 Locations PAGE No. and Messages

IC.61

12.61


LOCATION

MESSAGE

3L-10.25

10-25

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-10.39

10-39

Apartment ID

3L-10.26

10-26

3L-10.40

10-40

3L-10.27

10-27

3L-10.41

10-41

3L-10.28

10-28

3L-10.42

10-42

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-10.29 Apartment ID

3L-10.30 Apartment ID

10-29

10-30

3L-10.43 Apartment ID

3L-10.45 Apartment ID

10-43

10-45

There is no T-44 indicated on the plan.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations siteFloor checked Buildings 2 and 3 - must Code be - Tenth

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-10.31 Apartment ID

10-31

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-10.32 Apartment ID

10-32

REVISE AND RESUBMIT

10-33

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

10-34

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-10.33 Apartment ID

3L-10.34 Apartment ID

3L-10.35 Apartment ID

3L-10.36 Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

10-35

10-36

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-10.37 Apartment ID

10-37

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-10.38 Apartment ID

10-38

SHEET NO.

Tenth Floor

8 Locations PAGE No. and Messages

IC.62

12.62


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-11.2

3L-11.1

3L-11.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-11.4 3L-11.27

3L-11.26

3L-11.6

3L-11.5

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2L-11.52

3A-11.1

3C-11.1 3E-11.1 3L-11.8

3A-11.3

3L-11.10 3J-11.2 3L-11.18

3J-11.4 3J-11.5 3L-11.11

3L-11.15

2L-11.56

3L-11.24

3L-11.23 3L-11.25

3L-11.12 3L-11.14

3L-11.16

04.21.2021

Buildings 2 and 3 - Code - Eleventh Floor CLIENT APPROVAL

JH

DRAWN BY

2E-11.4 SUBMITTAL: DATE:

3J-11.6

Not Approved

3L-11.36

Approved as Noted

2L-11.62

2L-11.61

3L-11.37

REVIEWED BY:

2L-11.60 2L-11.59

APPROVED

3C-11.4 3A-11.4

3L-11.39 3L-11.41

3L-11.17

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

2L-11.57

3L-11.35 3C-11.2

2L-11.58

2L-11.55

3L-11.34 3L-11.21

DOCUMENT NAME / SUBMITTAL DATE

2A-11.5

3E-11.3

3E-11.2

3L-11.19

3L-11.13 3A-11.2

3L-11.20

3L-11.22

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2C-11.5

2J-11.9

3L-11.32 3J-11.8

3J-11.7

2L-11.54

2L-11.53

3C-11.3

3L-11.33

3J-11.3

3L-11.9

3L-11.30

3L-11.31

3J-11.1

3L-11.7

2L-11.51

3L-11.28

3L-11.29

3L-11.43

2J-11.10

3L-11.38

REVISE AND RESUBMIT

2L-11.63 2J-11.11

3L-11.40 3L-11.42

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

2L-11.64 2J-11.12 2L-11.66

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

2L-11.65 3L-11.45

2L-11.67

No.

2L-11.68 2A-11.6 2L-11.70

2C-11.6 2L-11.69

2L-11.72

2L-11.71 2L-11.74 2L-11.73

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

11 Eleventh Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Eleventh Floor

SECTION PAGE No.

8 Locations and Messages

IC.63

SHEET NO.

12.63


LOCATION

MESSAGE

2A : Stair ID

2A-11.5 Stair ID

2A-11.6 Stair ID

Egress Direction

2C-11.6

Egress Direction

CLIENT REMARKS

Total Qty: 2

STAIR 2-1

2J-11.10

Room ID (FOH)

Total Qty: 2

ELECTRICAL ROOM

11 LEVEL 11

2J-11.12

ELECTRICAL ROOM

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2L : Apartment ID

Room ID (FOH)

2L-11.51 Apartment ID

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

Total Qty: 4

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 24

11-51

INTERIOR CODE SIGNAGE

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Eleventh Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

2L-11.52 Apartment ID

STAIR 2-2 ROOF ACCESS

2E : Evac/In Case of Fire

CLIENT REMARKS

ELEC/ TELECOM ROOM

2J-11.11

Room ID (FOH)

DESIGNER NOTES

TRASH

STAIR 2-1 ROOF ACCESS

11-52

APPROVED

Approved as Noted

REVISE AND RESUBMIT

2L-11.53

11-53

2L-11.54

11-54

Apartment ID

Apartment ID

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Evac/In Case of Fire

MESSAGE

2J : Room ID (FOH)

Room ID (FOH)

11 LEVEL 11

2E-11.4

LOCATION

2J-11.9

STAIR 2-2

2C : Egress Direction

2C-11.5

DESIGNER NOTES

2L-11.55

11-55

2L-11.56

11-56

Apartment ID

Total Qty: 1

Apartment ID

2L-11.57 Apartment ID

2L-11.58 Apartment ID

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

11-57

11-58

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Eleventh Floor

8 Locations PAGE No. and Messages

IC.64

12.64


LOCATION

MESSAGE

2L-11.59

11-59

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

2L-11.73

11-73

Apartment ID

2L-11.60

11-60

2L-11.74

2L-11.61

11-61

3A : Stair ID

Apartment ID

Apartment ID

Apartment ID

2L-11.62 Apartment ID

Apartment ID

Apartment ID

3A-11.2

STAIR 3-2

Apartment ID

2L-11.66 Apartment ID

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3A-11.3

DOCUMENT NAME / SUBMITTAL DATE

STAIR 3-3

11-64

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Eleventh Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3A-11.4

Approved

STAIR 3-4

SUBMITTAL: DATE: REVIEWED BY:

Not Approved

11-65 3C : Egress Direction

11-66

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

11-63

Stair ID

2L-11.65

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

11-62

Stair ID

2L-11.64

INTERIOR CODE SIGNAGE

Total Qty: 4

STAIR 3-1

Stair ID

2L-11.63

CLIENT REMARKS

11-74

3A-11.1 Stair ID

DESIGNER NOTES

3C-11.1

Egress Direction

STAIR 3-1 ROOF ACCESS

Total Qty: 4

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

2L-11.67 Apartment ID

2L-11.68 Apartment ID

2L-11.69 Apartment ID

2L-11.70 Apartment ID

11-67

11-68

11-69

11-70

11 LEVEL 11 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

2L-11.71 Apartment ID

11-71

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

2L-11.72 Apartment ID

11-72

SHEET NO.

Eleventh Floor

8 Locations PAGE No. and Messages

IC.65

12.65


LOCATION

MESSAGE

3C-11.2

STAIR 3-2 ROOF ACCESS

Egress Direction

11 LEVEL 11 LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-11.3

Egress Direction

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Egress Direction

CLIENT REMARKS

LOCATION

STAIR 3-4 ROOF ACCESS

3E-11.1

Evac/In Case of Fire

3E-11.2

Evac/In Case of Fire

CLIENT REMARKS

Total Qty: 3

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

DOCUMENT NAME / SUBMITTAL DATE

[EVAC MAP HOLDER]

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Eleventh Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3E-11.3

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

[EVAC MAP HOLDER] 3J : Room ID (FOH)

3J-11.1

3J-11.2

Room ID (FOH)

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

DESIGNER NOTES

[EVAC MAP HOLDER]

Room ID (FOH)

11 LEVEL 11

MESSAGE

3E : Evac/In Case of Fire

STAIR 3-3 ROOF ACCESS 11 LEVEL 11

3C-11.4

DESIGNER NOTES

3J-11.3

Room ID (FOH)

TRASH

ELECTRICAL ROOM ELECTRICAL ROOM

3J-11.4

GAS METER ROOM

3J-11.5

ELECTRICAL ROOM

Room ID (FOH)

Room ID (FOH)

Total Qty: 8

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Eleventh Floor

8 Locations PAGE No. and Messages

IC.66

12.66


LOCATION

MESSAGE

3J-11.6

Room ID (FOH)

3J-11.7

Room ID (FOH)

3J-11.8

Room ID (FOH)

LOCATION

MESSAGE

GAS METER ROOM

3L-11.11

11-11

ELEC/ TELECOM ROOM

3L-11.12

11-12

3L-11.13

11-13

3L-11.14

11-14

HOUSEKEEPING

3L : Apartment ID

3L-11.1

Apartment ID

3L-11.2

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

Apartment ID

Apartment ID

Apartment ID Room is not named on plan. Client to confirm room designation.

Total Qty: 44

11-01

Apartment ID

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-11.15 Apartment ID

11-02

DESIGNER NOTES

3L-11.16 Apartment ID

11-15

11-16

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Eleventh Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-11.3

Apartment ID

11-03

3L-11.17 Apartment ID

11-17

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-11.4

Apartment ID

11-04

3L-11.18 Apartment ID

11-18

REVISE AND RESUBMIT

11-19

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

11-20

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-11.5

Apartment ID

3L-11.6

Apartment ID

3L-11.7

Apartment ID

3L-11.8

Apartment ID

3L-11.9

Apartment ID

3L-11.10 Apartment ID

11-05

3L-11.19 Apartment ID

11-06

3L-11.20 Apartment ID

11-07

3L-11.21 Apartment ID

11-08

3L-11.22 Apartment ID

11-09

1 Round 2

11-21

11-22

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-11.23 Apartment ID

11-10

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

11-23

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-11.24 Apartment ID

11-24

SHEET NO.

Eleventh Floor

8 Locations PAGE No. and Messages

IC.67

12.67


LOCATION

MESSAGE

3L-11.25

11-25

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-11.39

11-39

Apartment ID

3L-11.26

11-26

3L-11.40

11-40

3L-11.27

11-27

3L-11.41

11-41

3L-11.28

11-28

3L-11.42

11-42

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-11.29 Apartment ID

3L-11.30 Apartment ID

11-29

11-30

3L-11.43 Apartment ID

3L-11.45 Apartment ID

11-43

11-45

There is no T-44 indicated on the plan.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Eleventh Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-11.31 Apartment ID

11-31

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-11.32 Apartment ID

11-32

REVISE AND RESUBMIT

11-33

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

11-34

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-11.33 Apartment ID

3L-11.34 Apartment ID

3L-11.35 Apartment ID

3L-11.36 Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

11-35

11-36

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-11.37 Apartment ID

11-37

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-11.38 Apartment ID

11-38

SHEET NO.

Eleventh Floor

8 Locations PAGE No. and Messages

IC.68

12.68


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-12.2

3L-12.1

3L-12.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-12.4 3L-12.27

3L-12.26

3L-12.6

3L-12.5

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

2L-12.52

3A-12.1

3C-12.1 3E-12.1 3L-12.8

3A-12.3

3L-12.10 3J-12.2 3L-12.18

3J-12.4 3J-12.5 3L-12.11

2L-12.56

3L-12.24

3L-12.23 3L-12.25

3C-12.2 3L-12.12 3L-12.14

3L-12.16

04.21.2021

Buildings 2 and 3 - Code - Twelfth Floor CLIENT APPROVAL

JH

DRAWN BY

2E-12.4 SUBMITTAL: DATE:

3J-12.6

Not Approved

3L-12.36

Approved as Noted

2L-12.62

2L-12.61

3L-12.37

REVIEWED BY:

2L-12.60 2L-12.59

APPROVED

3C-12.4 3A-12.4

3L-12.39 3L-12.41

3L-12.17

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

2L-12.57

3L-12.35

3A-12.2

2L-12.58

2L-12.55

3L-12.34 3L-12.21

DOCUMENT NAME / SUBMITTAL DATE

2A-12.5

3E-12.3

3E-12.2

3L-12.19

3L-12.13

3L-12.15

3L-12.20

3L-12.22

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2C-12.5

2J-12.9

3L-12.32 3J-12.8

3J-12.7

2L-12.54

2L-12.53

3C-12.3

3L-12.33

3J-12.3

3L-12.9

3L-12.30

3L-12.31

3J-12.1

3L-12.7

2L-12.51

3L-12.28

3L-12.29

3L-12.43

2J-12.10

3L-12.38

REVISE AND RESUBMIT

2L-12.63 2J-12.11

3L-12.40 3L-12.42

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE

2L-12.64 2J-12.12 2L-12.66

DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

2L-12.65 3L-12.45

2L-12.67

No.

2L-12.68 2A-12.6 2L-12.70

2C-12.6 2L-12.69

2L-12.72

2L-12.71 2L-12.74 2L-12.73

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

12 Twelfth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Twelfth Floor

SECTION PAGE No.

8 Locations and Messages

IC.69

SHEET NO.

12.69


LOCATION

MESSAGE

2A : Stair ID

2A-12.5 Stair ID

2A-12.6 Stair ID

Egress Direction

2C-12.6

Egress Direction

CLIENT REMARKS

Total Qty: 2

STAIR 2-1

2J-12.10

Room ID (FOH)

Total Qty: 2

ELECTRICAL ROOM

12 LEVEL 12

2J-12.12

ELECTRICAL ROOM

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2L : Apartment ID

Room ID (FOH)

2L-12.51 Apartment ID

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

Total Qty: 4

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 24

12-51

INTERIOR CODE SIGNAGE

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Twelfth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

2L-12.52 Apartment ID

STAIR 2-2 ROOF ACCESS

2E : Evac/In Case of Fire

CLIENT REMARKS

ELEC/ TELECOM ROOM

2J-12.11

Room ID (FOH)

DESIGNER NOTES

TRASH

STAIR 2-1 ROOF ACCESS

12-52

APPROVED

Approved as Noted

REVISE AND RESUBMIT

2L-12.53

12-53

2L-12.54

12-54

Apartment ID

Apartment ID

LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Evac/In Case of Fire

MESSAGE

2J : Room ID (FOH)

Room ID (FOH)

12 LEVEL 12

2E-12.4

LOCATION

2J-12.9

STAIR 2-2

2C : Egress Direction

2C-12.5

DESIGNER NOTES

2L-12.55

12-55

2L-12.56

12-56

Apartment ID

Total Qty: 1

Apartment ID

2L-12.57 Apartment ID

2L-12.58 Apartment ID

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

12-57

12-58

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Twelfth Floor

8 Locations PAGE No. and Messages

IC.70

12.70


LOCATION

MESSAGE

2L-12.59

12-59

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

2L-12.73

12-73

Apartment ID

2L-12.60

12-60

2L-12.74

2L-12.61

12-61

3A : Stair ID

Apartment ID

Apartment ID

Apartment ID

2L-12.62 Apartment ID

Apartment ID

Apartment ID

3A-12.2

STAIR 3-2

Apartment ID

2L-12.66 Apartment ID

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3A-12.3

DOCUMENT NAME / SUBMITTAL DATE

STAIR 3-3

12-64

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Twelfth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3A-12.4

Approved

STAIR 3-4

SUBMITTAL: DATE: REVIEWED BY:

Not Approved

12-65 3C : Egress Direction

12-66

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

12-63

Stair ID

2L-12.65

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

12-62

Stair ID

2L-12.64

INTERIOR CODE SIGNAGE

Total Qty: 4

STAIR 3-1

Stair ID

2L-12.63

CLIENT REMARKS

12-74

3A-12.1 Stair ID

DESIGNER NOTES

3C-12.1

Egress Direction

STAIR 3-1 ROOF ACCESS

Total Qty: 4

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

2L-12.67 Apartment ID

2L-12.68 Apartment ID

2L-12.69 Apartment ID

2L-12.70 Apartment ID

12-67

12-68

12-69

12-70

12 LEVEL 12 LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

2L-12.71 Apartment ID

12-71

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

2L-12.72 Apartment ID

12-72

SHEET NO.

Twelfth Floor

8 Locations PAGE No. and Messages

IC.71

12.71


LOCATION

MESSAGE

3C-12.2

STAIR 3-2 ROOF ACCESS

Egress Direction

12 LEVEL 12 LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-12.3

Egress Direction

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Egress Direction

CLIENT REMARKS

LOCATION

STAIR 3-4 ROOF ACCESS

3E-12.1

Evac/In Case of Fire

3E-12.2

Evac/In Case of Fire

CLIENT REMARKS

Total Qty: 3

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

DOCUMENT NAME / SUBMITTAL DATE

[EVAC MAP HOLDER]

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Twelfth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

3E-12.3

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

[EVAC MAP HOLDER] 3J : Room ID (FOH)

3J-12.1

3J-12.2

Room ID (FOH)

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

DESIGNER NOTES

[EVAC MAP HOLDER]

Room ID (FOH)

12 LEVEL 12

MESSAGE

3E : Evac/In Case of Fire

STAIR 3-3 ROOF ACCESS 12 LEVEL 12

3C-12.4

DESIGNER NOTES

3J-12.3

Room ID (FOH)

TRASH

ELECTRICAL ROOM ELECTRICAL ROOM

3J-12.4

GAS METER ROOM

3J-12.5

ELECTRICAL ROOM

Room ID (FOH)

Room ID (FOH)

Total Qty: 8

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Twelfth Floor

8 Locations PAGE No. and Messages

IC.72

12.72


LOCATION

MESSAGE

3J-12.6

Room ID (FOH)

3J-12.7

Room ID (FOH)

3J-12.8

Room ID (FOH)

LOCATION

MESSAGE

GAS METER ROOM

3L-12.11

12-11

ELEC/ TELECOM ROOM

3L-12.12

12-12

3L-12.13

12-13

3L-12.14

12-14

HOUSEKEEPING

3L : Apartment ID

3L-12.1

Apartment ID

3L-12.2

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

Apartment ID

Apartment ID

Apartment ID Room is not named on plan. Client to confirm room designation.

Total Qty: 44

12-01

Apartment ID

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-12.15 Apartment ID

12-02

DESIGNER NOTES

3L-12.16 Apartment ID

12-15

12-16

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Twelfth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-12.3

Apartment ID

12-03

3L-12.17 Apartment ID

12-17

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-12.4

Apartment ID

12-04

3L-12.18 Apartment ID

12-18

REVISE AND RESUBMIT

12-19

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

12-20

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-12.5

Apartment ID

3L-12.6

Apartment ID

3L-12.7

Apartment ID

3L-12.8

Apartment ID

3L-12.9

Apartment ID

3L-12.10 Apartment ID

12-05

3L-12.19 Apartment ID

12-06

3L-12.20 Apartment ID

12-07

3L-12.21 Apartment ID

12-08

3L-12.22 Apartment ID

12-09

1 Round 2

12-21

12-22

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-12.23 Apartment ID

12-10

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

12-23

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-12.24 Apartment ID

12-24

SHEET NO.

Twelfth Floor

8 Locations PAGE No. and Messages

IC.73

12.73


LOCATION

MESSAGE

3L-12.25

12-25

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-12.39

12-39

Apartment ID

3L-12.26

12-26

3L-12.40

12-40

3L-12.27

12-27

3L-12.41

12-41

3L-12.28

12-28

3L-12.42

12-42

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-12.29 Apartment ID

3L-12.30 Apartment ID

12-29

12-30

3L-12.43 Apartment ID

3L-12.45 Apartment ID

12-43

12-45

There is no T-44 indicated on the plan.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Twelfth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-12.31 Apartment ID

12-31

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-12.32 Apartment ID

12-32

REVISE AND RESUBMIT

12-33

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

12-34

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-12.33 Apartment ID

3L-12.34 Apartment ID

3L-12.35 Apartment ID

3L-12.36 Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

12-35

12-36

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-12.37 Apartment ID

12-37

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-12.38 Apartment ID

12-38

SHEET NO.

Twelfth Floor

8 Locations PAGE No. and Messages

IC.74

12.74


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3L-13.2

3L-13.1

3L-13.3

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

3L-13.4 3L-13.27

3L-13.26

3L-13.6

3L-13.5 3A-13.1

3C-13.1

3L-13.28

3L-13.29

3E-13.1 3L-13.8

3A-13.3

3L-13.10 3J-13.2 3L-13.18

3J-13.4 3J-13.5 3L-13.11

3L-13.15

DOCUMENT NAME / SUBMITTAL DATE

3L-13.32 3J-13.8 3E-13.3

3J-13.7 3L-13.24

3E-13.2

3L-13.19

3L-13.13 3A-13.2

3L-13.20

3L-13.22

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

3C-13.3

3L-13.33

3J-13.3

3L-13.9

3L-13.30

3L-13.31

3J-13.1

3L-13.7

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

3L-13.23 3L-13.25

3L-13.12 3L-13.14

3L-13.17 3L-13.16

Buildings 2 and 3 - Code - Thirteenth Floor CLIENT APPROVAL

JH

DRAWN BY

SUBMITTAL: DATE:

3J-13.6

Not Approved

3L-13.36

REVIEWED BY:

3L-13.35 3C-13.2

04.21.2021

CLIENTApproved REQUIRED APPROVAL

3L-13.34 3L-13.21

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

OPEN TO BELOW

3L-13.37

Approved as Noted

APPROVED

3C-13.4 3A-13.4

3L-13.38

3L-13.39 3L-13.41

3L-13.40

3L-13.43

REVISE AND RESUBMIT

3L-13.42

3L-13.45

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

13 Thirteenth Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Thirteenth Floor

SECTION PAGE No.

8 Locations and Messages

IC.75

SHEET NO.

12.75


LOCATION

MESSAGE

3A : Stair ID

3A-13.1 Stair ID

3A-13.2 Stair ID

LOCATION

MESSAGE

Total Qty: 4

3C-13.3

STAIR 3-3 ROOF ACCESS

Egress Direction

3A-13.4

STAIR 3-4 Egress Direction

3C-13.1

Egress Direction

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-13.4

3C : Egress Direction

DESIGNER NOTES

13 LEVEL 13

STAIR 3-2

STAIR 3-3

Stair ID

CLIENT REMARKS

STAIR 3-1

3A-13.3 Stair ID

DESIGNER NOTES

Total Qty: 4

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

STAIR 3-4 ROOF ACCESS 13 LEVEL 13

STAIR 3-1 ROOF ACCESS

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Thirteenth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3C-13.2

Egress Direction

STAIR 3-2 ROOF ACCESS

REVIEWED BY:

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

13 LEVEL 13

3E : Evac/In Case of Fire

3E-13.1

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

Total Qty: 3

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

13 LEVEL 13 LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

[EVAC MAP HOLDER] 3E-13.2

Evac/In Case of Fire

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS [EVAC MAP HOLDER]

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Thirteenth Floor

8 Locations PAGE No. and Messages

IC.76

12.76


LOCATION

MESSAGE

3E-13.3

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

Evac/In Case of Fire

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L : Apartment ID

3L-13.1

Apartment ID

3J : Room ID (FOH)

Room ID (FOH)

Total Qty: 8

13-01

3L-13.2

13-02

3L-13.3

13-03

Apartment ID

TRASH Apartment ID

3J-13.2

Room ID (FOH)

ELECTRICAL ROOM

3L-13.4

Apartment ID

3J-13.3

Room ID (FOH)

ELECTRICAL ROOM

Room ID (FOH)

3J-13.5

Room ID (FOH)

3J-13.6

Room ID (FOH)

3J-13.7

Room ID (FOH)

3L-13.5

Room ID (FOH)

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

13-04

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Thirteenth Floor

DRAWN BY JH

13-05

Approved SUBMITTAL: DATE:

Not Approved

3L-13.6

Apartment ID

13-06

APPROVED

Approved as Noted

REVISE AND RESUBMIT

ELEC/ TELECOM ROOM

3L-13.7

13-07

GAS METER ROOM

3L-13.8

13-08

ELEC/ TELECOM ROOM

3L-13.9

13-09

3L-13.10

13-10

HOUSEKEEPING

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

REVIEWED BY:

GAS METER ROOM

Apartment ID

Apartment ID

Apartment ID

Apartment ID

3J-13.8

Numbering approach shown on this floor doesn't mach lower floors. Designer is suggesting to match lower floors. Note applies to all L signs on this floor.

INTERIOR CODE SIGNAGE

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Apartment ID

3J-13.4

CLIENT REMARKS

Total Qty: 44

[EVAC MAP HOLDER]

3J-13.1

DESIGNER NOTES

Room is not named on plan. Client to confirm room designation.

3L-13.11 Apartment ID

3L-13.12 Apartment ID

13-11

13-12

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Thirteenth Floor

8 Locations PAGE No. and Messages

IC.77

12.77


LOCATION

MESSAGE

3L-13.13

13-13

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

3L-13.27

13-27

Apartment ID

3L-13.14

13-14

3L-13.28

13-28

3L-13.15

13-15

3L-13.29

13-29

3L-13.16

13-16

3L-13.30

13-30

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3L-13.17 Apartment ID

3L-13.18 Apartment ID

13-17

13-18

3L-13.31 Apartment ID

3L-13.32 Apartment ID

13-31

13-32

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Thirteenth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE:

3L-13.19 Apartment ID

13-19

3L-13.33 Apartment ID

13-33

REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3L-13.20 Apartment ID

13-20

3L-13.34 Apartment ID

13-34

REVISE AND RESUBMIT

13-35

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

13-36

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

CONTENTS:

3L-13.21 Apartment ID

3L-13.22 Apartment ID

3L-13.23 Apartment ID

3L-13.24 Apartment ID

13-21

13-22

13-23

13-24

3L-13.35 Apartment ID

3L-13.36 Apartment ID

3L-13.37 Apartment ID

3L-13.38 Apartment ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

13-37

13-38

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3L-13.25 Apartment ID

13-25

3L-13.39 Apartment ID

13-39

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

3L-13.26 Apartment ID

13-26

3L-13.40 Apartment ID

13-40

SHEET NO.

Thirteenth Floor

8 Locations PAGE No. and Messages

IC.78

12.78


LOCATION

MESSAGE

3L-13.41

13-41

Apartment ID

3L-13.42

13-42

3L-13.43

13-43

3L-13.45

13-45

Apartment ID

Apartment ID

Apartment ID

DESIGNER NOTES

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

There is no T-44 indicated on the plan on lower floors, so designer suggests skipping that number on this floor as well.

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Thirteenth Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Thirteenth Floor

8 Locations PAGE No. and Messages

IC.79

12.79


INTERIOR CODE SIGNAGE CLIENT 7440 Fort Smallwood Rd. GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

3G-14.2

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE 3G-14.1 3K-14.1

3G-14.6

3J-14.1 3A-14.1

3A-14.2 2G-14.12 3G-14.8

3C-14.1

3K-14.2

3G-14.4

3J-14.3

3C-14.3

3J-14.7

3F-14.4

2J-14.12 2A-14.9

04.21.2021

Buildings 2 and 3 - Code - Rooftop Floor CLIENT APPROVAL

JH

SUBMITTAL: DATE:

Not Approved

2J-14.15

3A-14.7

REVIEWED BY:

2J-14.14

3F-14.6

3A-14.4

3F-14.7

3F-14.11 3F-14.12

Approved as Noted

APPROVED

2F-14.14

2F-14.13

3C-14.4 3J-14.9

3A-14.8

3G-14.5

DRAWN BY

2E-14.4

3G-14.10

3C-14.2

NOT FORPackage CONSTRUCTION Design-Build - POST FINAL REVISED FOR CLIENT REVIEW ONLY All locations must be site checked SHEET NAME

CLIENTApproved REQUIRED APPROVAL

3J-14.8

3F-14.5

3F-14.8

2G-14.13

2J-14.13

3E-14.3

3G-14.7

3F-14.2 3F-14.3

DOCUMENT NAME / SUBMITTAL DATE

2J-14.10

3A-14.6

3E-14.2

3F-14.1

Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

2A-14.10

2J-14.11

3J-14.22

3J-14.4 3J-14.5

3G-14.3

3A-14.3

3F-14.9

2C-14.5

2G-14.11

2K-14.5

3F-14.10

2K-14.4

3A-14.5

3E-14.1 3J-14.2

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copyLLC list for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

REVISE AND RESUBMIT

2G-14.14

3J-14.6 3K-14.3

2J-14.19 2J-14.18

2G-14.15

3G-14.9 2J-14.16

2J-14.21

2J-14.17 2F-14.15

2J-14.20

2F-14.16

2A-14.11 2G-14.16 2C-14.6

SUBMISSION INFORMATION CONTENTS: Wayfinding Signs 2-9-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND REVISIONS PERMITTING PRIOR TO FABRICATION.

No.

Description

Date

:::: ::::REQUIRING APPROVAL BY DESIGNER ::-::-::AND OWNER PRIOR SUBMITTALS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO 1 Round 2 2-18-21 TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

R Roof Floor Plan Scale: 1:500

LOCATION WHERE GRAPHICPLANS LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

Roof

SECTION PAGE No.

8 Locations and Messages

IC.80

SHEET NO.

12.80


LOCATION

MESSAGE

2A : Stair ID

2A-14.9 Stair ID

2A-14.10 Stair ID

2A-14.11 Stair ID

Egress Direction

STAIR 2-1

MESSAGE

DESIGNER NOTES

2E : Evac/In Case of Fire

2E-14.4

Evac/In Case of Fire

Total Qty: 1

Total Qty: 2

2F-14.13 Restroom ID

STAIR 2-1 ROOF ACCESS

R ROOF LEVELS 1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

2F-14.14 Restroom ID

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

2F : Restroom ID

STAIR 2-2 ROOF ACCESS

CLIENT REMARKS

[EVAC MAP HOLDER]

STAIR 2-2

LEVELS P1-12 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

Egress Direction

LOCATION

STAIR 2-1

R ROOF

2C-14.6

CLIENT REMARKS

Total Qty: 3

2C : Egress Direction

2C-14.5

DESIGNER NOTES

Total Qty: 4

[WOMEN RESTROOM/ ACCESSIBLE SYMBOL] WOMEN

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

[MEN RESTROOM/ ACCESSIBLE SYMBOL] MEN

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Rooftop Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

2F-14.15 Restroom ID

2F-14.16 Restroom ID

Not Approved

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

APPROVED

Approved as Noted

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

2G : Max Occupancy

Total Qty: 6

2G-14.11

MAX OCCUPANCY XX

Capitol View

2G-14.12

MAX OCCUPANCY XX

Capitol View Roof

MAX OCCUPANCY XX

Building 2 Roof

Max Occupancy

Max Occupancy

2G-14.13

Max Occupancy

2G-14.14

Max Occupancy

MAX OCCUPANCY XX

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

Open Lounge

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Roof

8 Locations PAGE No. and Messages

IC.81

12.81


LOCATION

MESSAGE

DESIGNER NOTES

2G-14.15

MAX OCCUPANCY XX

Business Center

MAX OCCUPANCY XX

Building 2 Pool

Max Occupancy

2G-14.16

Max Occupancy

2J : Room ID (FOH)

STORAGE

Room is not named on plan. Client to confirm room designation.

2J-14.11

STORAGE

Room is not named on plan. Client to confirm room designation.

Room ID (FOH)

2J-14.12

Room ID (FOH)

STORAGE

Room is not named on plan. Client to confirm room designation.

LOCATION

MESSAGE

DESIGNER NOTES

2J-14.20

STORAGE

Room is not named on plan. Client to confirm room designation.

Room ID (FOH)

2J-14.21

Room ID (FOH)

Total Qty: 12

2J-14.10

Room ID (FOH)

CLIENT REMARKS

CAPITOL VIEW LOUNGE

Install with vinyl backer.

2K-14.5

CAPITOL VIEW LOUNGE

Install with vinyl backer.

Ammenity ID

3A : Stair ID

3A-14.1

Room ID (FOH)

Room ID (FOH)

3A-14.2 Room is not named on plan. Client to confirm room designation.

Room ID (FOH)

STORAGE

3A-14.3

Room ID (FOH)

MEETING ROOM

Room is not named on plan. Client to confirm room designation.

Room is not named on plan. Client to confirm room designation. Install with vinyl backer.

2J-14.17

Room ID (FOH)

WORK ROOM 1

3A-14.4

Room is not named on plan. Client to confirm room designation.

3A-14.5 Stair ID

3A-14.6 Stair ID

3A-14.7 Room ID (FOH)

WORK ROOM 2

Room is not named on plan. Client to confirm room designation. Install with vinyl backer.

2J-14.19

Room ID (FOH)

WORK ROOM 3

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Rooftop Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved

STAIR 3-1

Room is not named on plan. Client to confirm room designation. Install with vinyl backer.

REVIEWED BY:

Not Approved

APPROVED

STAIR 3-2

REVISE AND RESUBMIT

STAIR 3-2

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE

STAIR 3-3

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

Stair ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

1 Round 2

STAIR 3-3

Install with vinyl backer.

2J-14.18

Design-Build Package - POST FINAL REVISED

CONTENTS:

Stair ID

2J-14.16

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

Approved as Noted

Stair ID

2J-14.15

STAIR 3-1

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

DOCUMENT NAME / SUBMITTAL DATE

Total Qty: 8

CATERING

STORAGE

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

SUBMITTAL: DATE:

Stair ID

2J-14.14

7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

Total Qty: 2

2K-14.4

Ammenity ID

INTERIOR CODE SIGNAGE

Room is not named on plan. Client to confirm room designation.

2K : Ammenity ID

Stair ID

2J-14.13

STORAGE

CLIENT REMARKS

STAIR 3-4

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

3A-14.8 Stair ID

STAIR 3-4

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Roof

8 Locations PAGE No. and Messages

IC.82

12.82


LOCATION

MESSAGE

3C : Egress Direction

3C-14.1

Egress Direction

STAIR 3-1 ROOF ACCESS

DESIGNER NOTES

CLIENT REMARKS

LOCATION

MESSAGE

Total Qty: 4

3C-14.4

STAIR 3-4 ROOF ACCESS

Egress Direction

3C-14.2

Egress Direction

STAIR 3-2 ROOF ACCESS

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

R ROOF

R ROOF LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

DESIGNER NOTES

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW] 3E : Evac/In Case of Fire

3E-14.1

Evac/In Case of Fire

R ROOF

Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822

Total Qty: 3

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

3C-14.3

Egress Direction

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Rooftop Floor

DRAWN BY JH

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

3E-14.2

Evac/In Case of Fire

STAIR 3-3 ROOF ACCESS R ROOF

Design-Build Package - POST FINAL REVISED

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

[EVAC MAP HOLDER] LEVELS P2-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

DOCUMENT NAME / SUBMITTAL DATE

Approved as Noted

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

REVISE AND RESUBMIT

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

[EVAC MAP HOLDER] 3E-14.3

Evac/In Case of Fire

LEVELS 1-13 EXIT DOWN TO LEVEL 1 [DOWN ARROW]

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

[FIRE STAIR SYMBOL] IN CASE OF FIRE USE STAIRS

1 Round 2

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.

[EVAC MAP HOLDER] 3F : Restroom ID

3F-14.1

Restroom ID

Total Qty: 12

[UNISEX RESTROOM SYMBOL] RESTROOM

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Roof

8 Locations PAGE No. and Messages

IC.83

12.83


LOCATION

MESSAGE

DESIGNER NOTES

3F-14.2

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

Accessible

Restroom ID

3F-14.3

Restroom ID

3F-14.4

Restroom ID

3F-14.5

Restroom ID

CLIENT REMARKS

LOCATION

MESSAGE

3F-14.12

[MEN RESTROOM/ ACCESSIBLE SYMBOL] MEN

Restroom ID

[UNISEX RESTROOM SYMBOL] RESTROOM

3G : Max Occupancy

[UNISEX RESTROOM SYMBOL] RESTROOM

3G-14.2

3G-14.1

Max Occupancy

Max Occupancy

3G-14.3

[UNISEX RESTROOM SYMBOL] RESTROOM

Max Occupancy

3G-14.4

Max Occupancy

3F-14.6

Restroom ID

3F-14.7

Restroom ID

3F-14.8

Restroom ID

[UNISEX RESTROOM SYMBOL] RESTROOM [UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

3G-14.5

Max Occupancy

Accessible

3G-14.6

3G-14.7

Max Occupancy

3G-14.8

Max Occupancy

3F-14.9

Restroom ID

3F-14.10 Restroom ID

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

Accessible

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM

Accessible

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS Total Qty: 10

MAX OCCUPANCY XX

Beer Garden

MAX OCCUPANCY XX

Beer Garden Roof

MAX OCCUPANCY XX

Restroom ID

[WOMEN RESTROOM/ ACCESSIBLE SYMBOL] WOMEN

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

Demo Kitchen

MAX OCCUPANCY XX

Demo Kitchen Roof

MAX OCCUPANCY XX

Roof Seating Building 3

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Rooftop Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

APPROVED

Approved as Noted

3G-14.9

Max Occupancy

3G-14.10

Max Occupancy

MAX OCCUPANCY XX

Roof Seating Building 3

MAX OCCUPANCY XX

Roof Seating Building 3

MAX OCCUPANCY XX

Building 3 Pool

MAX OCCUPANCY XX

Roof Seating Building 3

MAX OCCUPANCY XX

Roof Seating Building 3

3J-14.1

Room ID (FOH)

STORAGE

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

3J : Room ID (FOH)

3F-14.11

CLIENT REMARKS

REVISE AND RESUBMIT

Max Occupancy

[UNISEX RESTROOM SYMBOL] RESTROOM

DESIGNER NOTES

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.

Total Qty: 10 Room is not named on plan. Client to confirm room designation.

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS.

WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Roof

8 Locations PAGE No. and Messages

IC.84

12.84


LOCATION

MESSAGE

DESIGNER NOTES

3J-14.2

HOUSEKEEPING

Room is not named on plan. Client to confirm room designation.

Room ID (FOH)

3J-14.3

STORAGE

Room is not named on plan. Client to confirm room designation.

3J-14.4

SHOWER

Room is not named on plan. Client to confirm room designation.

3J-14.5

STORAGE

Room is not named on plan. Client to confirm room designation.

Room ID (FOH)

Room ID (FOH)

Room ID (FOH)

CLIENT REMARKS

INTERIOR CODE SIGNAGE 7440 Fort Smallwood Rd. CLIENT GREYSTAR WORLDWIDE, LLC Baltimore, MD 21226 ILLUME CAPITOL YARDS

main 410.255.6400 | 800.854.0568 gablecompany.com

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Drive, Suite Reference copy list for500 copy McLean, VA 22102 specific to each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE

3J-14.6

Room ID (FOH)

3J-14.7

Room ID (FOH)

STORAGE

STORAGE

Room is not named on plan. Client to confirm room designation.

Design-Build Package - POST FINAL REVISED

04.21.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations site checked Buildings 2 and 3 - must Code be - Rooftop Floor

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL

Room is not named on plan. Client to confirm room designation.

Approved SUBMITTAL: DATE: REVIEWED BY:

Not Approved

3J-14.8

Room ID (FOH)

STORAGE

Room is not named on plan. Client to confirm room designation.

APPROVED

Approved as Noted

REVISE AND RESUBMIT

3J-14.9

Room ID (FOH)

3J-14.22

Room ID (FOH)

STORAGE

STORAGE

Room is not named on plan. Client to confirm room designation.

SUBMISSION APPROVED AS INFORMATION NOTED Wayfinding Signs 2-9-2021 DRAWN BY: RO NOTE CHECKED BY: JH DESIGN-BUILD SCALE: AsDRAWINGS Noted ARE NOT FOR CONSTRUCTION AND REQUIRE CONTENTS:

Room is not named on plan. Client to confirm room designation.

3K : Ammenity ID

TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.

Total Qty: 3

SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR REVISIONS TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO No. Description Date TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, :::: OF::::MATERIALS, COLOR APPLICATIONS, ::-::-:: SAMPLES AND FINISHES.

1 Round 2

3K-14.1

BEER GARDEN

3K-14.2

DEMO KITCHEN

3K-14.3

MUSIC / MOVIE ROOM

Ammenity ID

Ammenity ID

Ammenity ID

Install with vinyl backer.

2-18-21

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

MESSAGES SECTION

SHEET NO.

Roof

8 Locations PAGE No. and Messages

IC.85

12.85


13

Reviewing Programming


Reviewing Programming

7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO.

STEP 1 MATCH LEVELS

STEP 2 CHOOSE A SIGN LOCATION

STEP 3 LOCATING ON PLAN

STEP 4 CONFIRM SIGN TYPE

STEP 5 CONFIRM SIGN MESSAGE

STEP 6 NOTATE

STEP 7 COMPLETE AND RETURN

Confirm you are referencing the same FLOOR on both the Sign Location Plan (figure 1.1) and the Sign Message Schedule (figure 1.2). The Sign Message Schedule is sorted by Floor first, then Sign Type, then Location.

Start with a location number in the Sign Message Schedule (figure 2.1).

Find the corresponding location number on the Sign Location Plan (figure 3.1). This is where that sign will be installed.

Confirm that the sign type listed is the preferred sign type to use at a particular location (figure 4.1).

Review the message shown within this area (figure 5.1). The copy is shown EXACTLY as it will appear on the sign.

Check “APPROVED” if the information on the sheet is all correct (figure 6.1).

The notated Sign Location Plans and Sign Message Schedule is the master list of revisions required for each specific location.

If you need to make a correction to the placement of a sign, mark it on the plan (figure 3.2).

If you need to make a correction to a sign type, mark it on the Sign Message Schedule (figure 4.2).

Compare this message to the room use indicated on the architectural floor plans and how the room will be utilized by the end user.

Check “REVISE AND RESUBMIT” if there is are discrepancies with a location, sign type, or message that require re-submittal of the document with the noted corrections (figure 6.2).

If you need to make a correction to a message, mark it on the Sign Message Schedule (figure 5.2).

Please make or compile all revisions/notes onto one document and electronically forward or send vial mail to the Gable Project Manager.

Check “APPROVED AS NOTED” if there is are discrepancies with a location, sign type, or message that DO NOT require re-submittal of the document (figure 6.3).

Graystar Worldwide, LLC 8405 Greensboro Drive, Suite 500 McLean, VA 22102 859-327-2628 Illume Capitol Yards - Wayfinding & Signage Program Project No. 86822 DOCUMENT NAME / SUBMITTAL DATE Design-Build Package - POST FINAL REVISED

04.21.2021

SHEET NAME

DRAWN BY

Reviewing Programming

JH

CLIENT REQUIRED APPROVAL SUBMITTAL: DATE: REVIEWED BY:

CODE SIGN TYPES

K

Stair ID Level ID Egress Direction Exit ID Evac/In Case of Fire Restroom ID Max Occupancy Room ID (BOH) Room ID (FOH) Ammenity ID

L

Apartment ID

A B C

L-3.2

L-3.1

D E F

L-3.3

G

L-3.4

H

L-3.27

A-3.1

C-3.1

L-3.29

L-3.8

L-3.33

J-3.3 J-3.4 L-3.18 J-3.5

L-3.11

L-3.15

J-3.9

L-3.20

L-3.22

L-3.23

Figure 3.2

L-3.24

L-3.25

Sign Face

A-3.5

E-3.3

J-3.7

Illume Capitol Yards Wayfinding & Signage Program Project No. 86822

Loc No. Floor

F-3.1

Figure 1.1

J-3.10

F-3.2

NOT FOR Programming CONSTRUCTION Preliminary Submittal - Code FOR CLIENT REVIEW ONLY All locations SHEET NAME must be site checked

01.28.2021

THIRD FLOOR PLAN CLIENT APPROVAL

JH

SUBMITTAL:

J-3.6

Not Approved

L-3.36

J-3.11

L-3.38

L-3.41 L-3.16 L-3.43

[MEN RESTROOM/ ACCESSIBLE SYMBOL] MEN

Restroom ID

F-3.3

Restroom ID

REVISE AND RESUBMIT

L-3.40 L-3.42

DESIGNER NOTES

Figure 4.1

F-3.5

[UNISEX RESTROOM SYMBOL] RESTROOM

Confirm if restroom is accessible.

[UNISEX RESTROOM SYMBOL] RESTROOM

A-3.6 C-3.6 F-3.3 F-3.5

J-3.13

F-3.4 J-3.12 F-3.6

::::

J-3.2

ELECTRICAL ROOM

Room ID (FOH)

J-3.3

ELECTRICAL ROOM

J-3.4

GAS METER ROOM

J-3.5

ELEC/ TELECOM ROOM

Room ID (FOH)

Confirm if restroom is accessible.

J-3.7

Room ID (FOH)

| Total Qty: 6

J-3.8

Room ID (FOH)

Figure 4.2

J-3.9 Change to “H” Back of House

REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION No. Description Date INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

::::

Room is not named on plan. Client to confirm room designation.

J-3.6

REVISIONS

Figure 3.1

DESIGNER NOTES

TRASH

Room ID (FOH)

Figure 6.2

NOT FOR CONSTRUCTION - FOR CLIENT REVIEW ONLY

MESSAGE

J-3.1

Room ID (FOH) Confirm if restroom is accessible.

Restroom ID

LOCATION

Room ID (FOH)

[UNISEX RESTROOM/ ACCESSIBLE SYMBOL] RESTROOM [UNISEX RESTROOM SYMBOL] RESTROOM

Restroom ID

CLIENT REMARKS

Room ID (FOH)

F-3.4

F (Restroom ID)

SUBMISSION INFORMATION CONTENTS: Code Signage 1-22-2021 DRAWN BY: RO AS NOTED APPROVED CHECKED BY: JH SCALE: As Noted NOTES

L-3.45

Room ID (FOH)

GAS METER ROOM

HOUSEKEEPING

J-3.10

Room ID (FOH)

7440 Fort Smallwood Rd. Baltimore, MD 21226

CLIENT GREYSTAR WORLDWIDE, LLC ILLUME CAPITOL YARDS

STORAGE

Room ID (FOH)

ELEC/ TELECOM ROOM

J-3.12

STORAGE

J-3.13

HOUSEKEEPING

Room ID (FOH)

PROJECT CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Graystar Worldwide, LLC NOTES 8405 Greensboro Suite Reference copyDrive, list for copy500 McLean, VAto 22102 specific each sign location 859-327-2628 indicated on the plan with a unique number. Illume Capitol Yards Wayfinding & Signage Program Project No. 86822

Room is not named on plan. Client to confirm room designation.

Figure 5.1

DOCUMENT NAME / SUBMITTAL DATE Preliminary Programming Submittal - Code

Room is not named on plan. Client to confirm room designation.

Figure 1.2

01.28.2021

NOT FOR CONSTRUCTION SHEET FORNAME CLIENT REVIEW ONLY All locations must be site checked THIRD FLOOR MESSAGES

DRAWN BY JH

CLIENT APPROVAL CLIENT REQUIRED APPROVAL Approved

SUBMITTAL:

DATE:

REVIEWED BY:

Not Approved

There is a room, but no door. Client to confirm if there is a door that isn’t shown on the plan.

APPROVED

Approved as Noted

Figure 6.1

REVISE AND RESUBMIT

SUBMISSION APPROVED INFORMATION AS NOTED Code Signage 1-22-2021 RO JH

CONTENTS:

Figure 6.3

SECTION PAGE No.

IC.16

APPROVED AS NOTED

NOTE DESIGN-BUILD DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

DRAWN BY:

NOTES

NOTSCALE: FOR CONSTRUCTION - FOR CLIENT REVIEW ONLY As Noted

Room is not named on plan. Client to confirm room designation.

REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

REVISIONS

FABRICATOR SHALL BE RESPONSIBLE FOR: Date No. Description • ::::FINAL INDICATED, ::::DESIGN AND ENGINEERING OF COMPONENTS ::-::-:: INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. • COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. • VERIFICATION OF CONDITIONS IN FIELD PRIOR TO SUBMISSION OF SHOP DRAWINGS AND SAMPLES.

Room is not named on plan. Client to confirm room designation.

JANITOR

Figure 5.2

SUBMITTALS FOR APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDING BUT NOT LIMITED TO: SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

| Total Qty: 13

Third Floor

3 Interior Code Programming

REVISE AND RESUBMIT

main 410.255.6400 | 800.854.0568 gablecompany.com

ELECTRICAL ROOM

J-3.11

Room ID (FOH)

Figure 2.1

INTERIOR CODE SIGNAGE

CHECKED BY:

J (Room ID (FOH))

LOCATION PLANS

APPROVED

CLIENT REMARKS

ELEC/ TELECOM ROOM

::-::-::

FABRICATOR SHALL BE RESPONSIBLE FOR: • FINAL DESIGN AND ENGINEERING OF COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. • COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. • VERIFICATION OF CONDITIONS IN FIELD PRIOR TO SUBMISSION OF SHOP DRAWINGS AND SAMPLES. SUBMITTALS FOR APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDING BUT NOT LIMITED TO: SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.

3 Third Floor Plan Scale: 1:500

F-3.2

Restroom ID

C-3.4 A-3.4

[WOMEN RESTROOM/ ACCESSIBLE SYMBOL] WOMEN

Restroom ID

F-3.6

DATE:

APPROVED

L-3.37

L-3.39 L-3.17

DRAWN BY

Approved as Noted

C-3.2 L-3.12

MESSAGE

F-3.1

REVIEWED BY:

L-3.35

L-3.14

LOCATION

DOCUMENT NAME / SUBMITTAL DATE

CLIENTApproved REQUIRED APPROVAL

E-3.5

L-3.34 L-3.21

OWNER / ADDRESS / PROJECT NAME / PROJECT NO. NOTES Graystar Worldwide, Reference copy listLLC for copy 8405 Greensboro Drive, Suite 500 specific to each sign location McLean, VA 22102 indicated on the plan with 859-327-2628 a unique number.

C-3.5 J-3.8

E-3.2

L-3.19

L-3.13 A-3.2

C-3.3 L-3.32

J-3.2 L-3.9

Sign Type

A-3.3

L-3.10

main 410.255.6400 | 800.854.0568 PROJECT gablecompany.com CAMPUS, GARAGE, & INTERIOR CODE & WAYFINDING SIGNAGE

A-1.01

E-3.4

L-3.30

L-3.31

J-3.1

7440 Fort Smallwood Rd. Baltimore, MD 21226

CLIENT GREYSTAR WORLDWIDE, LLC ILLUME CAPITOL YARDS

L-3.28

E-3.1 L-3.7

J

L-3.26

L-3.6

L-3.5

INTERIOR CODE SIGNAGE

SHEET NO.

MESSAGES SECTION

SHEET NO.

3.15

3 Interior PAGE No.Code Programming IC.19

3.18

Third Floor

WALL SURFACES VARY AND INCLUDE DRYWALL, GLASS, WOOD, WALL COVERING, CERAMIC TILE, AND CMU BLOCK. WHEN MOUNTING TO GLASS, VINYL BACKPLATE IS REQUIRED PAINTED TO MATCH SIGN FACE. WHEN MOUNTING ALUMINUM SIGNS TO CMU BLOCK, STUD-MOUNTED METAL BACKPLATE IS REQUIRED. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE MOUNTING METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE. WHERE GRAPHIC LAYOUTS ARE NOT PROVIDED, REFERENCE COPY LIST FOR COPY SPECIFIC TO EACH SIGN LOCATION INDICATED ON THE PLAN WITH A UNIQUE NUMBER.

SECTION

SHEET NO.

13 Reviewing Programming

13.01


Gable 7440 Fort Smallwood Rd. Baltimore, MD 21226


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.