DESIGN STUDIO
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
SIGNAGE AND LANDSCAPE ARRIVAL AND SITE EXPERIENCE ASSESSMENT FINAL DESIGN PRESENTATION AGENDA 1.
EXISTING ENTRY + ARRIVAL REVIEW
2.
OBSERVATIONS + RECOMMENDATIONS
3.
GUIDING PRINCIPLES
4.
CAMPUS SIGNAGE PLAN
5.
CAMPUS LANDSCAPE MASTER PLAN
6.
VIDEO PRESENTATION
E X I S T I N G E N T R Y + A R R I VA L REVIEW
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
O B S E R VAT I O N S + R E C O M M E N D AT I O N S
LORIEN HEALTH | COLUMBIA
E NR ET CO RY M +M A ER N R IDAT V A LI O N S | E N T RY A N D A R R I VA L EQUIPMENT
LORIEN NURSING CENTER
GILCHRIST CENTER HOWARD COUNTY
CORNER GATEWAY + SIGNAGE OPPORTUNITY
PARKING LOT ID SIGNAGE NE
HARMONY HALL
CE DA R
LA
IMPROVE CONNECTIVITY
ENHANCED ENTRY DRIVE WAYFINDING SIGNAGE PRIMARY ENTRANCE ACCENTS
Entry Gateway + Digital Element
ENTRY GATEWAY AND DIGITAL ELEMENT
Entry Accents
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021 MAY 28, 2021 2
LORIEN HEALTH | COLUMBIA
EN C AR EMCO P UM SM AC T IDAT V ATI O I ONNS | CA M P U S AC T I VAT I O N CAMPUS LOOP TRAIL / SIGNAGE
GILCHRIST CENTER HOWARD COUNTY
LORIEN NURSING CENTER
WATER FEATURE
LA
NE
HARMONY HALL
CE DA R
GAZEBO DINING TERRACE GAZEBO
Campus Loop Trail + Signage
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021 MAY 28, 2021 5
LORIEN HEALTH | COLUMBIA
MG E N+DAT S CR RE ECO E NMI N S OI O F TNESN|I NS C GR E E N I N G + SO F T E N I N G
GILCHRIST CENTER HOWARD COUNTY
CE DA R
LA
HARMONY HALL
NE
LORIEN NURSING CENTER
Iconic Entry Plantings
Perennial Plantings to Soften Edges + Ground Building
Strategic Screening of Equipment + Perimeter
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021 MAY 28, 2021 4
LORIEN HEALTH | COLUMBIA
R EMCO CO CO M UMNMI TE N Y DAT C E LI EOBNR SAT|I O N M M U N I T Y C E L E B RAT I O N
LORIEN NURSING CENTER
GILCHRIST CENTER HOWARD COUNTY
FACADE IMPROVEMENTS
WATER TANK MURAL
CE DA R
LA
NE
HARMONY HALL
Artful Placemaking
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021 MAY 28, 2021 7
GUIDING PRINCIPLES
SUPPORT THE BRAND THROUGH THOUGHTFUL PLACEMENT OF IDENTITY COMPONENTS
SUPPORT THE LANDSCAPE INTENT OF THE SPACE THROUGH THE INTEGRATION OF THE WAYFINDING AND SIGNAGE COMPONENTS
DESIGN FOR DURABILITY, LONGEVITY, AND SUSTAINABILITY WHILE BEING ABLE TO ACCOMMODATE FOR CHANGEABILITY AND EXPANSION
CAMPUS SIGNAGE
CONCEPT B - INSPIRATION
FUTURA - DEMI ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 0123456789 FUTURA - BOOK ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 0123456789
BLACK
BRAND CHARCOAL GRAY
WHITE
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
Custom Sign Panel Pattern
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
Custom Sign Panel Pattern
JH
CLIENT REQUIRED APPROVAL SUBMITTAL:
DATE:
REVIEWED BY: APPROVED Final crenetaled tab placement TBD by waterjet sub (typ.)
REVISE AND RESUBMIT APPROVED AS NOTED
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
ACCENT PANEL Campus ID
ACCENT PANEL Primary Vehicular Directional
ACCENT PANEL Secondary Vehicular Directional Building ID
ACCENT PANEL Parking Lot ID
SECTION
SHEET NO.
2 Graphic Standards
2.03
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
PRIMARY VEHICULAR DIRECTIONAL
A - SIGN PANEL Material: 34“ x 48” x 0.125” thk aluminum pan - 2“ deep, provide internal support and full-sized back plate Background Process: Surface painted Rule Line Process: Applied matte vinyl - 0.5” tall Arrow Process: Applied reflective vinyl - 6” tall Copy Process: Applied reflective vinyl - 2.75” tall Colors: As noted Mounting Method: Weld back plate to Accent Panel as needed, provide concealed tamper-resistant fasteners for face removal
2’-0”
3’-0”
C
P1
V2
B - ACCENT PANEL Material: 0.1” thk. aluminum, waterjet cut as shown Background Process: Surface painted - all areas Color: As noted Mounting Method: Provide crenelated tabs for mounting into Sign Frame, spot weld as required - Ref. Sheet 2.03 C - SIGN FRAME Material: 1” x 5“ x 0.125” thk. aluminum tube frame, routed on inside to accept Accent Panel tabs Background Process: Surface painted - all areas Color: As noted Mounting Method: J-bolt to “at grade” concrete footer, as required by Structural Engineer
4’-0”
8’-0”
main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
Primary Vehicular Directional
JH
CLIENT REQUIRED APPROVAL
V1
Nursing Center MedStar Health Urgent Care Personal Physician Care Kidney Care
7440 Fort Smallwood Rd. Baltimore, MD 21226
SUBMITTAL:
V1
DATE:
REVIEWED BY: APPROVED REVISE AND RESUBMIT
A P2
APPROVED AS NOTED
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS.
2’-0”
FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.
SCALE: 1” = 1’-0”
FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
B P2
ELEVATION VIEW
SECTION VIEW
SECTION
SHEET NO.
3 Sign Details
3.02
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
SECONDARY VEHICULAR DIRECTIONAL
A - SIGN PANEL Material: 34“ x 24” x 0.125” thk aluminum pan - 2“ deep, provide internal support and full-sized back plate Background Process: Surface painted Rule Line Process: Applied matte vinyl - 0.5” tall Arrow Process: Applied reflective vinyl - 6” tall Copy Process: Applied reflective vinyl - 2.75” tall Colors: As noted Mounting Method: Weld back plate to Accent Panel as needed, provide concealed tamper-resistant fasteners for face removal B - ACCENT PANEL Material: 0.1” thk. aluminum, waterjet cut as shown Background Process: Surface painted - all areas Color: As noted Mounting Method: Provide crenelated tabs for mounting into Sign Frame, spot weld as required - Ref. Sheet 2.03 3’-0”
C - SIGN FRAME Material: 1” x 5“ x 0.125” thk. aluminum tube frame, routed on inside to accept Accent Panel tabs Background Process: Surface painted - all areas Color: As noted Mounting Method: Mounting Method: J-bolt to “at grade” concrete footer, as required by Structural Engineer
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
Secondary Vehicular Directional
JH
2’-0”
CLIENT REQUIRED APPROVAL C
SUBMITTAL:
P1
DATE:
REVIEWED BY: APPROVED REVISE AND RESUBMIT
V2
APPROVED AS NOTED
NOTE
2’-0”
6’-0”
V1
Harmony Hall Gilchrist Center
DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.
V1
SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.
A P2
GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS.
2’-0”
FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.
SCALE: 1” = 1’-0”
FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
B P2
ELEVATION VIEW
SECTION VIEW
SECTION
SHEET NO.
3 Sign Details
3.03
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
PARKING LOT ID
A - SIGN PANEL Material: 16“ x 48” x 0.125” thk aluminum pan - 2“ deep, provide internal support and full-sized back plate Background Process: Surface painted Rule Line Process: Applied matte vinyl - 0.5” tall Symbol Process: Applied reflective vinyl - 9” dia Symbol Copy Process: Applied reflective vinyl - 2“ tall Copy Process: Applied matte vinyl - 2.75” tall Colors: As noted Mounting Method: Weld back plate to Accent Panel as needed, provide concealed tamper-resistant fasteners for face removal B - ACCENT PANEL Material: 0.1” thk. aluminum, waterjet cut as shown Background Process: Surface painted - all areas Color: As noted Mounting Method: Provide crenelated tabs for mounting into Sign Frame, spot weld as required - Ref. Sheet 2.03
1’-6”
P
Visitors
C - SIGN FRAME Material: 1” x 5“ x 0.125” thk. aluminum tube frame, routed on inside to accept Accent Panel tabs Background Process: Surface painted - all areas Color: As noted Mounting Method: Mounting Method: J-bolt to “at grade” concrete footer, as required by Structural Engineer C
P1
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
Parking Lot ID
JH
CLIENT REQUIRED APPROVAL
V1
SUBMITTAL:
DATE:
REVIEWED BY:
V1 V2
APPROVED
LORIEN COLUMBIA
6’-0”
4’-0”
REVISE AND RESUBMIT APPROVED AS NOTED
V1
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.
A P2
SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS.
2’-0”
FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.
SCALE: 1” = 1’-0”
FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
B P2
ELEVATION VIEW
SECTION VIEW
SECTION
SHEET NO.
3 Sign Details
3.04
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
BUILDING ID
A - SIGN PANEL Material: 34“ x 48” x 0.125” thk aluminum pan - 2“ deep, provide internal support and full-sized back plate Background Process: Surface painted Rule Line Process: Applied matte vinyl - 0.5” tall Header Copy Process: Applied reflective vinyl - 2.75” tall Department Copy Process: Applied reflective vinyl - 2” tall Colors: As noted Mounting Method: Weld back plate to Accent Panel as needed, provide concealed tamper-resistant fasteners for face removal B - ACCENT PANEL Material: 0.1” thk. aluminum, waterjet cut as shown Background Process: Surface painted - all areas Color: As noted Mounting Method: Provide crenelated tabs for mounting into Sign Frame, spot weld as required - Ref. Sheet 2.03 3’-0”
LORIEN COLUMBIA
C - SIGN FRAME Material: 1” x 5“ x 0.125” thk. aluminum tube frame, routed on inside to accept Accent Panel tabs Background Process: Surface painted - all areas Color: As noted Mounting Method: Mounting Method: J-bolt to “at grade” concrete footer, as required by Structural Engineer C
P1
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
Building ID
JH
CLIENT REQUIRED APPROVAL SUBMITTAL:
V1 V2
APPROVED
4’-0”
Nursing Center MedStar Health Urgent Care
6’-0”
Personal Physician Care
DATE:
REVIEWED BY:
REVISE AND RESUBMIT APPROVED AS NOTED
V1
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.
A P2
SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.
Kidney Care
GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS.
2’-0”
FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT.
SCALE: 1” = 1’-0”
FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
B P2
ELEVATION VIEW
SECTION VIEW
SECTION
SHEET NO.
3 Sign Details
3.05
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
RESERVED PARKING ID
A - SIGN PANEL Material: 0.125” thk aluminum Background Process: Surface painted Rule Line Process: Applied matte vinyl - 0.25” tall Header Copy Process: Applied reflective vinyl - 1“ tall Colors: As noted Mounting Method: Screws to Post with tamper-resistant fasteners (Stop Sign shown as typical example, see NOTE below) B - POST Material: 2” x 2“ x 0.125” thk. aluminum post - cap top Background Process: Surface painted - all areas Color: As noted Mounting Method: Direct-burial to concrete footer NOTE: Shuttle Bus Only Signs - 3 each Employee of the Month Signs - 1 each Star of the Month Signs - 1 each
1’-0”
V1
1’-6”
RESERVED PARKING
EMPLOYEE OF THE MONTH A
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
V2
Reserved Parking ID
JH
V1
CLIENT REQUIRED APPROVAL
RESERVED PARKING
P1
SUBMITTAL:
DATE:
REVIEWED BY:
SHUTTLE BUS ONLY
APPROVED REVISE AND RESUBMIT APPROVED AS NOTED
4’-6”
6’-0”
RESERVED PARKING
EMPLOYEE OF THE MONTH
B P2
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS.
RESERVED PARKING
STAR OF THE MONTH
SCALE: 1” = 1’-0”
ELEVATION VIEW
SIDE VIEW
FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
GRAPHIC LAYOUTS SECTION
SHEET NO.
3 Sign Details
3.06
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
TRAFFIC REGULATORY
A - SIGN PANEL Product: Standard traffic regulatory sign with reflective face Mounting Method: Screws to Post w/ tamper-resistant fasteners (Stop Sign shown as typical example, see NOTE below) B - POST Material: 2” x 2“ x 0.125” thk. aluminum post - cap top Background Process: Surface painted - all areas Color: As noted Mounting Method: Direct-burial to concrete footer SIGN PANEL NOTE: Stop Signs - 2 each Speed Limit 15 Signs - 4 each Do Not Enter Signs - 1 each Accessible Parking Signs w/ $350 Fine Signs - 17 each Varies
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
Traffic Regulatory
JH
Varies
CLIENT REQUIRED APPROVAL SUBMITTAL:
A
DATE:
REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED
NOTE 6’-0”
DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.
Varies
SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES.
B P2
GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
SCALE: 1” = 1’-0”
ELEVATION VIEW
SIDE VIEW
SECTION
SHEET NO.
3 Sign Details
3.07
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com
Parking Lot ID Remove existing sign, maintain sign angle, provide 4 foot setback, location requires grade survey for footer
OWNER / ADDRESS / PROJECT NAME / PROJECT NO.
Parking Lot ID New sign location, provide 4 foot set-back, location requires grade survey for footer
Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1
Parking Lot ID Remove existing sign, maintain sign angle, provide 4 foot setback, location requires grade survey for footer
Campus ID (wall and pylon) New sign location, remove all existing site id signs, location requires grade survey for footer
DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
ID Sign Locations
JH
CLIENT REQUIRED APPROVAL SUBMITTAL:
Parking Lot ID New sign location, center left/right on top of concrete island, location requires grade survey for footer
DATE:
REVIEWED BY: APPROVED REVISE AND RESUBMIT
Building ID New sign location, provide 4 foot set-back, location requires grade survey for footer
APPROVED AS NOTED
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
SECTION
SHEET NO.
4 Sign Locations & Messages
3.09
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300
Parking Lot ID New sign location, provide 4 foot set-back from end of island - and center front/back, location requires grade survey for footer
Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
ID Sign Locations
JH
CLIENT REQUIRED APPROVAL SUBMITTAL:
DATE:
REVIEWED BY: APPROVED REVISE AND RESUBMIT
Parking Lot ID New sign location, provide 4 foot set-back, location requires grade survey for footer
Parking Lot ID New sign location, provide 4 foot set-back, location requires grade survey for footer
Parking Lot ID New sign location, provide 4 foot set-back, location requires grade survey for footer
APPROVED AS NOTED
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
SECTION
SHEET NO.
4 Sign Locations & Messages
3.10
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
Parking Lot ID New sign location, provide min. 4 foot set-back, location requires grade survey for footer
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1
Parking Lot ID New sign location, provide min. 4 foot set-back, location requires grade survey for footer
DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
ID Sign Locations
JH
CLIENT REQUIRED APPROVAL SUBMITTAL:
DATE:
REVIEWED BY: APPROVED REVISE AND RESUBMIT APPROVED AS NOTED
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION.
Parking Lot ID New sign location, provide 4 foot set-back, location requires grade survey for footer
SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
Building ID New sign location, provide 4 foot set-back, location requires grade survey for footer
SECTION
SHEET NO.
4 Sign Locations & Messages
3.11
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
7440 Fort Smallwood Rd. Baltimore, MD 21226
Secondary Vehicular Directional Remove existing sign, maintain sign angle, provide 4 foot set-back, location requires grade survey for footer Primary Vehicular Directional Remove existing sign, maintain sign angle, provide 4 foot setback, location requires grade survey for footer
Secondary Vehicular Directional New sign location, provide 4 foot set-back, location requires grade survey for footer Primary Vehicular Directional Remove existing sign, maintain sign angle, provide 4 foot setback, location requires grade survey for footer
main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
Vehicular Sign Locations
JH
CLIENT REQUIRED APPROVAL SUBMITTAL:
DATE:
REVIEWED BY: APPROVED REVISE AND RESUBMIT
Secondary Vehicular Directional Remove existing sign, maintain sign angle, provide 4 foot set-back, location requires grade survey for footer
APPROVED AS NOTED
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
SECTION
SHEET NO.
4 Sign Locations & Messages
4.01
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO. Secondary Vehicular Directional New sign location, provide 4 foot set-back, location requires grade survey for footer
Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
Vehicular Sign Locations
JH
CLIENT REQUIRED APPROVAL SUBMITTAL:
DATE:
REVIEWED BY: APPROVED
Secondary Vehicular Directional Remove existing sign, maintain sign angle, center left/right in island, location requires grade survey for footer
REVISE AND RESUBMIT APPROVED AS NOTED
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS.
Primary Vehicular Directional Remove existing sign, maintain sign angle, provide 4 foot setback, location requires grade survey for footer
FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
SECTION
SHEET NO.
4 Sign Locations & Messages
4.02
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
7440 Fort Smallwood Rd. Baltimore, MD 21226 main 410.255.6400 | 800.854.0568 gablecompany.com OWNER / ADDRESS / PROJECT NAME / PROJECT NO.
Secondary Vehicular Directional New sign location, provide 4 foot set-back, location requires grade survey for footer
Lorien Health 3300 N. Ridge Road, Suite 390 Ellicott City, MD 21043 410-531-5300 Lorien Health Columbia - Exterior Wayfinding & Signage Program Project No. 87510-1 DOCUMENT NAME / SUBMITTAL DATE
Secondary Vehicular Directional Remove existing sign, maintain sign angle, provide 4 foot set-back and center left/right in island, location requires grade survey for footer
Concept-Level Pricing Package
08.02.2021
SHEET NAME
DRAWN BY
Vehicular Sign Locations
JH
CLIENT REQUIRED APPROVAL SUBMITTAL:
DATE:
REVIEWED BY:
Secondary Vehicular Directional New sign location, center between windows and center front/back in landscape, location requires grade survey for footer
APPROVED REVISE AND RESUBMIT APPROVED AS NOTED
Secondary Vehicular Directional Remove existing sign, maintain sign angle, provide 4 foot set-back, location requires grade survey for footer
NOTE DRAWINGS ARE NOT FOR CONSTRUCTION AND REQUIRE TECHNICAL SHOP DRAWINGS, ENGINEERING, TECHNICAL FIELD SURVEY, AND PERMITTING PRIOR TO FABRICATION. SUBMITTALS REQUIRING APPROVAL BY DESIGNER AND OWNER PRIOR TO FABRICATION AND INSTALLATION, INCLUDE BUT ARE NOT LIMITED TO TECHNICAL SHOP DRAWINGS, GRAPHIC LAYOUTS OF ALL SIGN LOCATIONS, SAMPLES OF MATERIALS, COLOR APPLICATIONS, AND FINISHES. GROUND SURFACES VARY AND INCLUDE LAWN AND MULCHED AREAS. WHEN INSTALLING IN LAWN, PROVIDE STEEL LANDSCAPE EDGE AROUND SIGN BASE AND RIVER ROCK INFILL. TECHNICAL FIELD SURVEY IS REQUIRED PRIOR TO FABRICATION TO VERIFY QUANTITY OF VARIOUS MOUNTING CONDITIONS AND APPROPRIATE INSTALLATION METHODS. FABRICATOR SHALL BE RESPONSIBLE - IN COORDINATION WITH DESIGNER - FOR FINAL DESIGN AND ENGINEERING OF ALL COMPONENTS INDICATED, INCLUDING ALL ASPECTS OF MOUNTING, ERECTION, ANCHORING, AND ATTACHMENT. FABRICATOR SHALL BE RESPONSIBLE FOR COORDINATION WITH OTHER TRADES, INCLUDING BUT NOT LIMITED TO ELECTRICAL, LIGHTING, STRUCTURAL, COMMUNICATIONS, AND LANDSCAPE.
SECTION
SHEET NO.
4 Sign Locations & Messages
4.03
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
CAMPUS LANDSCAPE MASTER PLAN
LORIEN HEALTH | COLUMBIA
MAST E R P L A N - O V E RV I E W
STORMWATER
FUTURE PARKING LOT
MANAGEMENT ZONE; TYP.
GILCHRIST CENTER HOWARD COUNTY
MEDSTAR HEALTH LORIEN NURSING CENTER
CE DA R
LA
NE
HARMONY HALL
MAIN ENTRY DRIVE STORMWATER MANAGEMENT ZONE; TYP. GATEWAY ENTRANCE EXISTING TREE COVER
SCALE: 1”= 100’ 0’
50’
100’
200’
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
LORIEN HEALTH | COLUMBIA
M AST E R P L A N - P R E C E D E N T I MAG E S
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
LORIEN HEALTH | COLUMBIA
MAST E R P L A N - P H AS I N G
1B
PHASE 2
PHASE 3
1B
PHASE 3
PHASE 1A
CE DA R
LA
NE
PHASE 1B
PHASE 2
SCALE: 1”= 100’ 0’
50’
100’
200’
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
LORIEN HEALTH | COLUMBIA
N E X T ST E PS - P H AS E 1 A FO C U S A R E A
MEDSTAR HEALTH LORIEN NURSING CENTER
GILCHRIST CENTER HOWARD COUNTY
HARMONY HALL
R DA E C
E N A L
FOCUS AREA
ENTRY & ARRIVAL
SCALE: 1”= 100’ 0’
50’
100’
200’
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
LORIEN HEALTH | COLUMBIA
E N T RY & A R R I VA L FO C U S A R E A
PARKING LOT; TYP. SPECIAL PAVERS IN CROSSWALK POLE LIGHT STREET TREE
EL EV AT IO N
MAIN ENTRY DRIVE
A
SEATING NOOK PRECAST CONCRETE ENTRY WALL ENTRY SIGN
EXISTING GAZEBO
PRECAST CONCRETE ENTRY WALL
B
CE DA R
ACCENT PLANTINGS
EL EV AT IO N
N E
LAWN
LA
POND
SCALE: 1”= 30’ 0’
15’
30’
60’
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
LORIEN HEALTH | COLUMBIA
ELEVATION A ENLARGEMENT BELOW
E N T RY & A R R I VA L E L E VAT I O N S
ELEVATION A SCALE: N.T.S.
ELEVATION A ENLARGEMENT SCALE: 3/32”= 1’-0”
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
LORIEN HEALTH | COLUMBIA
E N T RY & A R R I VA L E L E VAT I O N S
ELEVATION B
SCALE: 3/32”= 1’-0”
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
LORIEN HEALTH | COLUMBIA
E N T RY & A R R I VA L : MAT E R I A LS & P R E C E D E N TS
IN PROGRESS
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
LORIEN HEALTH | COLUMBIA
E N T RY & A R R I VA L : P L A N T PA L E T T E
Acer rubrum Red Maple
Quercus phellos ‘High Tower’ / Willow Oak
Cercis canadensis Eastern Redbud
Hydrangea quercifolia ‘Munchkin’ / Oakleaf Hydrangea
Hydrangea paniculata ‘Little Lime’ / Hydrangea
Clethra alnifolia ‘Hummingbird’ Summersweet
Panicum virgatum ‘Cape Breeze’ / Switchgrass
Schizachryium scoparium Little Bluestem
Amsonia x ‘Blue Ice’ Blue Ice Bluestar
Amsonia hubrichtii Threadleaf Bluestar
Monarda ‘Garden View Scarlet’ / Bee Balm
Asclepias incarnata Swamp Milkweed
Cornus florida Flowering Dogwood
Ilex glabra ‘Shamrock’ Shamrock Inkberry Holly
Penstemon digitalis ‘Husker Red’ / Beardtongue
Echinacea purpurea Purple Coneflower
Hamamelis virginiana Common Witchhazel
Eragrostis spectabilis Purple Lovegrass
Heuchera americana ‘Dale’s Strain’ Coral Bells
Dryopteris marginalis Marginal Woodfern
LORIEN HEALTH SERVICES | COLUMBIA CAMPUS - SIGNAGE + LANDSCAPE ARRIVAL + SITE EXPERIENCE ASSESSMENT #87510-1 | FINAL DESIGN PRESENTATION | GABLE DESIGN STUDIO / ENVIROCOLLAB | 08.30.2021
V I D E O P R E S E N TAT I O N
THANK YOU! 74 4 0 FORT SMALLWOOD ROAD BALTIMORE , MD 2 12 26 1.800.85 4.0568 W W W.GABLECOMPANY.COM