James Neal Beech House Final

Page 1

Beech House

James Neal ADC 273

A106 1

32' - 9" 12' - 3 23/32"

2

UP

2 A110 14 14R R@ 0'--777/16" @0' 7/16"

3 5

3' - 0 1/16"

10' - 0"

5 5

5

5

5

1 2

5

5

5

5

Powder room 5

5

5

9' - 9"

3

4' - 2"

3' - 0"

2

3

3

11 2

2

5

Living Room

1

14' - 5"

13' - 2"

2

3

A107

1 9

Kitchen

10' - 5"

A107

4

3' - 0"

1 9' - 9"

1 2

No.

Dinning Room 2

Description

Date

4

2

4 10

10

1

9' - 7"

4

9' - 7"

20' - 6" 1 4

18' - 1"

4

4 2 9' - 9 23/32"

15' - 1"

2 A106

James Neal First Floor 1/4" = 1'-0"

Project Number Issue Date Author Checker

Project number Date Drawn by Checked by

A104 1/4" = 1'-0"

Scale

8/14/2014 8:29:51 PM

1

Beech House First Floor Plan

A106 1

32' - 9"

2

4' - 1"

4' - 1"

15' - 1" 4' - 1" 9

DN

2

2

7 2

3 A110

2

2

2 5

5

6

6 5 5

7

5

8 5

7

5

5

5

2' - 6 1/16" 10

Master Bed

9

5

1 6

6

Bedroom 2

6

5

9 5

5

5

7 5

Bathroom 1

5

0' - 2 19/32" 2' - 9 1/2"

A107

5

3' - 1"

9

2

2

5

5

5 4

7

5 5

5

8

3' - 0 5/32"

9

5

3' - 0 1/16"

22' - 1"

5 2

1

5

5

22' - 1"

8

18' - 4"

3' - 0 1/16"

Bedroom 1

2

Master Bath 6

5 1

1

8

5

No.

Description

Date

8

2

2

2

24' - 7"

4

4 2 14' - 3"

15' - 1" 2 A106

James Neal Beech House Second Floor Plan

Second Floor 1/4" = 1'-0"

Project Number Issue Date Author Checker

Project number Date Drawn by Checked by

A105 1/4" = 1'-0"

Scale

Energy Usage in 90 Degree Orientation Water Usage and Costs

Annual Electric Use

Annual Fuel Use

Total: 77,007 Gal / yr $430 / yr Indoor: 66,108 Gal / yr $402 / yr Outdoor: 10,899 Gal / yr $28 / yr 3

Net Utility: 77,007 Gal / yr $430 / yr

Second View West and South 6

Second Floor North And East

Annual Energy Energy, Carbon and Cost Summary Annual Energy Cost - $8,744 Lifecycle Cost - $119,100 Annual CO2 - Emissions Electric - 0.8 tons

Energy Use Intensity (EUI) - 235 kBtu / ft² / year Electric - 20,082 kWh Fuel - 5,658 Therms Annual Peak Demand - 4.8 kW

No.

Description

Date

No.

2

First Floor View West and South 5

Description

Date

First Floor North And East

Lifecycle Energy Electric - 602,457 kW Fuel - 169,755 Therms

James Neal

James Neal

Beech House Energy Usage 90 Degree Oreintation

Beech House Parametric Model

Project Number Issue Date Author Checker

Project number Date Drawn by Checked by

A115 Scale

Project number

Project Number Issue Date Author Checker

Date

8/14/2014 8:31:02 PM

Large SUV Equivalent - 3.1 SUVs / Year

Drawn by Checked by

1

Basement View West and South 4

A113

Basement North And East Scale

8/14/2014 9:03:09 PM

Onsite Fuel - 32.8 tons

8/14/2014 8:30:28 PM

1


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.