i06
i07
i07 DRAWING
i09
1
i08 i06 DRAWING
1
i08 DRAWING
1
i10 i15
SIGN LOCATION PLAN
i11
i12
i16 i14
i17
i13
MCKALE ARENA GRAPHICS ACTIVATION
Tucson, AZ
DESIGN DEVELOPMENT PACKAGE
Admin Lobby Rendering
12
NOTE: DI will fabricate slat wall off site and install as unit in field.
NOTE:Contractor to paint finish wall.
Ceiling Condition: 2’ – 0” Gyp around perimeter with 2’ x 2’ lay-in ceiling at center 2
1” thick aluminum chanel letter lit. Face lighting and white halo back. Pin mount 1 1/2” away from wall.
PAGE
17'-6"
15
Access power in Ceiling Typical
4"
8'-8"
2"
5"
Power location Face to have paint receptive vinyl. Returns painted white.
8'-0"
10'-0"
10' - 0"
8’-0” Tall x 8’-8” Wide x 5” Deep
1'-0"
1” thick MDF slats painted to match (P-1) PMS 200, (F-1) gloss; Mounted to wall with adhesive. 4'-4"
1
Sign Detail
Scale: 3/8" =1'-0"
2
Left Side View Scale: 3/8" =1'-0"
3
Reverse Halo lit cap sign, White LED
Location Elevation
Tucson, AZ
DESIGN DEVELOPMENT PACKAGE
Flush mount to wall with adhesive.
Scale: 3/8" =1'-0"
* POWER NEEDED BEHIND SIGN CABINET 120V 5 AMP NEED ACCESS FOR REMOTE POWER SUPPLY & TO BACK OF SIGN.
MCKALE ARENA GRAPHICS ACTIVATION
3/4” thick MDF slats painted to match (P-1) PMS 200, (F-1) Gloss
Sign Type: i07 Event Level Elevator Lobby (West)
* PROVIDE ONE CIRCUIT (2#12CU, 1#12CU GRD, 3/4”C, 20A/1P BREAKER) FOR THE POWER; CIRCUIT IPCB-77
14
i09
i08
i10 i14 i11 i15 i12
i13
i13
DRAWING
4
i16 i13
DRAWING
i13
DRAWING
1
5
i13
SIGN LOCATION PLAN
MCKALE ARENA GRAPHICS ACTIVATION
Tucson, AZ
DESIGN DEVELOPMENT PACKAGE
Men’s Basketball Locker Room Vestibule
25